AN-80i PTP System

Quick Install Guide


RedCONNEX
TM
AN-80i PTP
Quick Install Guide
70-00074-01-04 Proprietary Redline Communications 2007 August 15, 2007
Page 2 of 12

Copyright Information
All rights reserved August 15, 2007. The information in this document is
proprietary to Redline Communications Inc. This document may not in whole
or in part be copied, reproduced, or reduced to any medium without prior
consent, in writing, from Redline Communications Incorporated.
Copyright 2007 Redline Communications Inc.

Contact Information:
Redline Communications Inc.
302 Town Centre Blvd. Suite 100
Markham, ON
Canada L3R 0E8
Web site:

http://www.redlinecommunications.com

Sales Inquiries:
North American
nainfo@redlinecommunications.com
Toll-free sales
1-866-633-6669
International
intlinfo@redlinecommunications.com
Support:
www.redlinecommunications.com/support/support_portal.html
Document Control:
70-00074-01-03-AN-80i_Quick_Install_Guide-20070815a.doc
Disclaimer
Every effort has been made to ensure the accuracy of the material provided
herein; however, Redline assumes no responsibility regarding the use of the
material. Additionally, Redline makes no representations or warranties, either
expressed or implied, regarding the contents of this product. Redline
Communications shall not be liable for any misuse regarding this product.
RedCONNEX
TM
AN-80i PTP
Quick Install Guide
70-00074-01-04 Proprietary Redline Communications 2007 August 15, 2007
Page 3 of 12

Table of Contents
1 Safety Notices .................................................................. 3
2 Important Service Information........................................ 3
3 Test Overview................................................................... 4
3.1 Required Test Facilities............................................... 4
3.2 Required Test Equipment............................................ 7
4 Assemble and Configure AN-80i .................................... 7
5 Configure AN-80i Systems.............................................. 7
6 Field Installation Instructions......................................... 9
Table of Figures
Figure 1: AN-80i Indoor Test Connection Diagram.................. 5
Figure 2: AN-80i Outdoor Test Connection Diagram............... 6
Figure 3: Configuration - Options Key...................................... 8
Figure 4: Mounting the AN-80i Antenna................................... 9
1 1 S Sa af fe et ty y N No ot ti ic ce es s
1. Do not exceed the described limits on product labels. Position power cords
to avoid damage. Do not overload wall outlets. Protect equipment by
disconnecting power when not in use.
2. Do not place PoE power adaptor on or near a direct heat source or operate
near water or in a wet location. Disconnect the PoE power before cleaning
and use only a damp cloth for cleaning. Do not use liquid or aerosol cleaners.
3. The AN-80i unit must not be located near power lines or other electrical
power circuits.
4. The AN-80i must be properly grounded to protect against power surges and
accumulated static electricity. It is the user's responsibility to install this
device in accordance with the local electrical codes and building codes:
grounding of the transceiver unit, mast, lead-in wire and discharge unit,
location of discharge unit, size of grounding conductors and connection
requirements for grounding electrodes.
2 2 I Im mp po or rt ta an nt t S Se er rv vi ic ce e I In nf fo or rm ma at ti io on n
1. Refer all repairs to qualified service personnel. Do not remove the covers or
modify any part of this device, as this voids the warranty.
2. Locate the serial numbers and record these on your registration card for
future reference. Record the MAC address located on the AN-80i.
RedCONNEX
TM
AN-80i PTP
Quick Install Guide
70-00074-01-04 Proprietary Redline Communications 2007 August 15, 2007
Page 4 of 12


3 3 T Te es st t O Ov ve er rv vi ie ew w
This Quick Install Guide provides steps for basic configuration and
operational testing of an AN-80i PTP link. This procedure assumes a setup
consisting of two complete AN-80i units. Refer to the AN-80i User Manual
and Installation Guidelines for additional safety instructions and for specific
operational and installation details.
3.1 Required Test Facilities
You will require the following to perform these tests:
1. Identify the RF channel(s) to be used.
2. Obtain a valid Options Key for each AN-80i unit. This key (string of
numbers, letters, and dashes) must be entered into AN-80i configuration to
allow full operation of the wireless link.
3. Record the MAC address for each system to be tested/installed (label on AN-
80i units). The MAC address is needed to identify each AN-80i and select
the correct Options Key to be entered.
4. One or two PCs each having an Ethernet interface port, Web browser
software installed (Internet Explorer recommended), and a CAT-5 cross-over
Ethernet cable for each PC.
5. A location with adequate space and power facilities.
6. To satisfy FCC and IC RF exposure requirements for RF transmitting
devices, the following distances should be maintained between the antenna
of this device and persons during device operation:
Table 1: FCC & IC RF Recommended Safe Separation
Distances
Frequency Separation Distance
5.4 GHz 40 centimeters or more
5.8 GHz
20 centimeters or more (PMP)
310 centimeters or more (PTP)
7. Redline does not endorse testing indoors with antennas. The operation of
antennas in close proximity results in poor connectivity due to high RF
multipath effect and RF saturation may damage equipment. Indoor testing
may require the use of an RF chamber.
When performing indoor testing the RF outputs from each AN-80i can be
connected together through a static/variable attenuator. Refer to the
connection diagrams on the following page.
RedCONNEX
TM
AN-80i PTP
Quick Install Guide
70-00074-01-04 Proprietary Redline Communications 2007 August 15, 2007
Page 5 of 12




Figure 1: AN-80i Indoor Test Connection Diagram



RedCONNEX
TM
AN-80i PTP
Quick Install Guide
70-00074-01-04 Proprietary Redline Communications 2007 August 15, 2007
Page 6 of 12




Figure 2: AN-80i Outdoor Test Connection Diagram
,
RedCONNEX
TM
AN-80i PTP
Quick Install Guide
70-00074-01-04 Proprietary Redline Communications 2007 August 15, 2007
Page 7 of 12

3.2 Required Test Equipment
1. PC#1: Use a crossover CAT-5 Ethernet cable to connect PC#1 to the PoE
Data In port on the AN-80i. Equipped with a Web browser (requires Internet
Explorer 6.0 or higher), and Ethernet port for connection to AN-80i (PTP
Slave). The IP address/subnet mask must be set for the same subnet as the
AN-80i. Recommended IP settings are:
IP address = 192.168.25.22, Net Mask = 255.255.255.0
2. PC#2: Use a crossover CAT-5 Ethernet cable to connect PC#2 to the PoE
Data In port on the AN-80i. Equipped with a Web browser and Ethernet port
for connection to AN-80i (PTP Master). The IP address/subnet mask must be
set for the same subnet as the AN-80i. Recommended IP settings are:
IP address = 192.168.25.23, Net Mask = 255.255.255.0
4 4 A As ss se em mb bl le e a an nd d C Co on nf fi ig gu ur re e A AN N- -8 80 0i i
Unpack the AN-80i and connect all components according to the Quick Test
wiring diagrams on page 5. Do not power-on the AN-80i unit at this time.
PoE Caution -- Warning to Service Personnel: 48 VDC
Customer equipment including personal computers, routers, etc., must be
connected only to the INPUT (DATA) port on the PoE unit. Only the outdoors
Ethernet interface cable connecting to the AN-80i can be safely connected to
the OUTPUT (DATA & POWER) connector. Connecting customer premises
Ethernet equipment directly to the OUTPUT (DATA & POWER) connector on
the Power-over-Ethernet power adapter may damage customer equipment.
5 5 C Co on nf fi ig gu ur re e A AN N- -8 80 0i i S Sy ys st te em ms s
1. Enter the AN-80i Options Key
a) Use an Ethernet cable to connect the PC #1 (192.168.25.22) to the INPUT
port of the PoE power adapter.
b) Power-on the AN-80i by connecting AC power to the PoE power adapter.
c) On the PC, open a browser and enter the default IP address (192.168.25.2).
Login to the AN-80i using the factory defaults:
Username: admin
Password: admin
d) Click Product Options in the left hand menu of the Web screen and enter the
options key for the this AN-80i unit. Every options key is unique to the
MAC address of an AN-80i and keys cannot be reused. Option keys are
provided by your local Redline equipment supplier. The options key enables
AN-80i features including the maximum Uncoded Burst Rate (UBR) and
frequency ranges (region codes). Without the options key, only very limited
operation is possible (restricted power, UBR, and frequency selection).
RedCONNEX
TM
AN-80i PTP
Quick Install Guide
70-00074-01-04 Proprietary Redline Communications 2007 August 15, 2007
Page 8 of 12


Figure 3: Configuration - Options Key
Important: If an AN-80i is placed in-service without first entering a
purchased permanent Options Key -- the wireless link will experience a
service outage.

2. Configure the AN-80i
For each link, one AN-80i unit must be designated as 'PTP Master' and the
second unit as 'PTP Slave'. When powered-on, the PTP Master will actively
transmit to establish a link with the (passive) PTP Slave.
Click Configure System in the left hand menu of the Web screen and make
the recommended settings for each AN-80i. It is recommended to first
configure the PTP Slave.
Table 2: Web - Recommended Settings
Setting PTP Slave PTP Master
IP Address 192.168.25.2 192.168.25.3
RF Freq. (MHz) Must match Master
RF setting
Set RF according to
network design
ATPC Enable
(Disabled) (Disabled)
Adaptive Modulation
(Enabled) (Enabled)
System Mode PTP Slave PTP Master
Encryption Type
None None
Link Length Measurement
Mode
Automatic Automatic
Radio Enable
(Enabled) (Enabled)
After making these settings, click Save at the bottom of the configuration
screen. If the IP address was changed, you must change the address entered
in the Web browser to match the new AN-80i IP address.
Repeat steps 1 & 2 to configure the PTP Master AN-80i using the second
test PC (192.168.25.23) if available. If only one PC is used, move the PC#1
Ethernet connection to the second PoE power adapter.
RedCONNEX
TM
AN-80i PTP
Quick Install Guide
70-00074-01-04 Proprietary Redline Communications 2007 August 15, 2007
Page 9 of 12

3. Test the Wireless Connection
The AN-80i units should now be operating on the same RF channel and will
automatically negotiate a wireless connection. Use the following steps to
verify connectivity:
a) From PC #2, enter the IP address of the PTP Slave AN-80i (192.168.25.2)
into the Web browser and login to the AN-80i unit.
b) On PC #2, open a command line window and use the following command
to send a ping message to PC#1 (192.168.25.22) over the wireless interface.
ping 192.168.25.22
You should observe a result similar to the following:
Reply from 192.168.25.22: bytes=32 time=1ms TTL=63
6 6 F Fi ie el ld d I In ns st ta al ll la at ti io on n I In ns st tr ru uc ct ti io on ns s
These steps should be performed after successfully completing the pre-
installation tests and configuration.
1. Install AN-80i
Install the AN-80i, mounting bracket, and antenna on the mast. Connect the
outdoor Ethernet cable from the AN-80i to the indoor PoE power adapter.
Important: Ethernet Plug Must 'Click' into Socket
When inserting the RJ-45 plug, you should hear an audible 'click' from
the plastic locking mechanism. Ensure the connector is locked before
sealing and weatherproofing the AN-80i. Do not use cables where this
locking mechanism is broken or has been removed!

Always follow local and national electrical and building codes for grounding
and safety. If you have determined that it is appropriate to install lightning
protection for your system, refer to the AN-80i Installation Guidelines
manual for additional information.

Figure 4: Mounting the AN-80i Antenna
RedCONNEX
TM
AN-80i PTP
Quick Install Guide
70-00074-01-04 Proprietary Redline Communications 2007 August 15, 2007
Page 10 of 12

2. Verify Free Channel (Spectrum Sweep)
It is recommended to check that the planned RF channel is available at the
deployment site. A spectrum sweep must be performed from both ends of the
link. When performing a sweep from the PTP Slave, the PTP Master must be
powered-off or have the transmitter disabled. The PTP Slave will remain
passive during a spectrum sweep from the PTP Master.
a) Login to the AN-80i Web interface and click Spectrum Sweep in the left
hand menu.
b) Enter the Start Frequency, End Frequency, and Step (multiple of 2.5 MHz) for
the spectrum to be scanned. Set the No of Acquisitions to '10' and click the Start
button to begin the scan.
c) After reviewing the results, enter a narrower frequency scan and higher
sample value to monitor a potentially clear channel.
d) Repeat the spectrum sweep from the remote-end AN-80i.
Note: It is also recommended to use the Redline RF Monitoring Tool. This
PC-based application continuously polls both ends of a wireless link and
graphs the RSSI and SINADR values in real time. Contact your Redline sales
representative to obtain this useful deployment and troubleshooting tool.
3. Align Antennas
a) Align each antenna in azimuth and elevation plane. Verify that RSSI values
at the base station and subscriber match your link budget predictions. If the
RSSI is not within 5 dB of the expected value, recheck the antenna
alignment and ensure there are no obstructions in the RF path. Record
RSSI/CINR as reference values.
b) If desired, you can enable the antenna alignment buzzer. This feature
provides an audible signal of the received signal strength (stronger signal-
>faster repetitions). Click Configure System in the left hand menu of the
Web screen and make the following setting:
Antenna Alignment Buzzer Enable: (Enabled)
The buzzer remains active until disabled by the operator.
4. Connect AN-80i to the Network
You should make all necessary changes to the AN-80i subscriber station
configuration before connecting to the network. Use a CAT-5 Ethernet cable
to connect the data network to the Data In port on the PoE power adapter.
Refer to the AN-80i User Manual and AN-80i Installation Guidelines
manual for further details.
RedCONNEX
TM
AN-80i PTP
Quick Install Guide
70-00074-01-04 Proprietary Redline Communications 2007 August 15, 2007
Page 11 of 12

Notes:




70-00074-01-04 Proprietary Redline Communications 2007 August 15, 2007
Page 12 of 12
302 Town Centre Suite 100 Markham, Ontario Canada L3R 0E8
www.redlinecommunications.com
Copyright 2007 Redline Communications Inc. All rights reserved. The information in this
document is subject to change without notice. The statements, configurations, technical data,
and recommendations in this document are believed to be accurate and reliable, but are
presented without express or implied warranty. Users must take full responsibility for their
applications of any products specified in this document. The information in this document is
proprietary to Redline Communications Inc.

Вам также может понравиться