Вы находитесь на странице: 1из 11

ndice

Objetivos ................................................................................................................................. 2

Introduccin ............................................................................................................................ 2

Marco Terico ......................................................................................................................... 2

Instrumentos a Utilizar ........................................................................................................... 6

Trabajo de Laboratorio ........................................................................................................... 7

Informe final ......................................................................................................................... 11

Conclusiones ............................................................................ Error! Marcador no definido.

Bibliografa ............................................................................... Error! Marcador no definido.










Objetivos


- Disear, analizar e implementar un filtro activo pasa banda.
- Comprobar parmetros de funcionamiento tales como: frecuencia de resonancia, ancho
de banda, factor de calidad (selectividad) y ganancia de la etapa.
- Analizar frecuencias y amplitudes de componentes armnicas de diverso orden filtradas a
partir de seales cuadradas alternas.


Introduccin


A continuacin analizaremos el comportamiento de un filtro pasa banda, desarrollando el
clculo terico y luego as comparar con lo obtenido prcticamente en el laboratorio. Este circuito
lo disearemos para que acepte una frecuencia especfica, asignada mediante los clculos
posteriormente desarrollados. Obtendremos las frecuencias de corte, el ancho banda, voltajes
mximos y mnimos y sus componentes armnicas en el tercer y quinto armnico.


Marco Terico


Filtro activo pasa banda con Amplificador Operacional

El diseo de este filtro corresponde a un filtro pasa banda de retroalimentacin mltiple
(MFB).

El filtro activo de retroalimentacin mltiple es un filtro paso de banda, sencillo y de buen
funcionamiento, para Qs de bajos a moderados, hasta de 10 aproximadamente.

Este circuito se muestra en la figura 1 observe que la retroalimentacin tiene lugar a
travs de C
1
y de R
3
(de ah el nombre de retroalimentacin mltiple). R
1
y C
1
proporcionan la
respuesta paso-bajas y R
3
y C
2
proporciona la maximizacin (Q) cerca de f
0
. R
2
se puede omitir;
pero se modifica el procedimiento de clculo de los componentes. R
2
eleva la R
ent
y ofrece una
ganancia controlable de banda de paso. En la seccin siguiente se calcula el circuito de las dos
maneras. Tambin los filtros de retroalimentacin mltiple se pueden construir como filtros
activos pasa altas y pasa bajas.

Los filtros activos se componen de resistores, capacitores y dispositivos activos como
Amplificadores Operacionales o transistores.

En un filtro activo la salida puede ser de igual o de mayor magnitud que la entrada.


Figura 1: filtro activo pasa banda

El filtro Pasa Banda tiene la siguiente curva de respuesta de frecuencia. Dejar pasar todas
las tensiones de la seal de entrada que tengan frecuencias entre la frecuencia de corte inferior f
1

y la de corte superior f
2
. Las tensiones fuera de este rango de frecuencias sern atenuadas y sern
menores al 70.7 % de la tensin de entrada.

Respuesta del filtro pasa banda

Las lneas discontinuas verticales sobre f1 y f2 y la lnea horizontal del 70.7% representan
la respuesta de un filtro pasa banda ideal.

Nota: f
1
y f
2
(frecuencias de corte) son puntos en la curva de transferencia en que salida ha cado 3
dB (decibeles) desde su valor mximo.


El amplificador operacional es un dispositivo lineal de propsito general el cual tiene
capacidad de manejo de seal desde f = 0 Hz. hasta una frecuencia definida por el fabricante; tiene
adems lmites de seal que van desde el orden de los nV, hasta unas docenas de voltio
(especificacin tambin definida por el fabricante). Los amplificadores operacionales se
caracterizan por su entrada diferencial y una ganancia muy alta, generalmente mayor que 105
equivalentes a 100dB.

El A.O es un amplificador de alta ganancia directamente acoplado, que en general se
alimenta con fuentes positivas y negativas, lo cual permite que tenga excursiones tanto por arriba
como por debajo de tierra (o el punto de referencia que se considere).

El nombre de Amplificador Operacional proviene de una de las utilidades bsicas de este,
como lo son realizar operaciones matemticas en computadores analgicos (caractersticas
operativas).

El Amplificador Operacional ideal se caracteriza por:

Resistencia de entrada,(Ren), tiende a infinito.
( ) in
I
+
e
( ) in
I

son cercanas a cero
Resistencia de salida, (Ro), tiende a cero.
Ganancia de tensin de lazo abierto, (A), tiende a infinito
0
Salida Salida Salida
V Entrada
Entrada V
V V V
A V
V A
= = = =


Ancho de banda (BW) tiende a infinito.
vo = 0 cuando v+ = v-


Condiciones de Diseo

Obtencin de la funcin de transferencia de un filtro pasa-banda de retroalimentacin mltiple
(MFB)

1 1 1 1
1 2
1 2
1 1
i o
V V V V V V
R R
sC sC

= + +
1
1
3 3 2
2
1
o o
V V V
V
R R C s
sC
= =
2
1
1
1 1 3 2 3 2
o
i o o
o
V C s
V V V C s
V C s
R R R C s R C s
/
+ =
/
3 2
R C s
2 3 2
o
V
R R C s

1
1
1 1 3 2 3 2 3 2 3 2
1 1 1
i
o
V C
V C s
R R R C s R C R R R C s
| |
=
|
\ .

2
2 1 2 1 1 2 3 1 2 1 2 2 1
2 3 2
i o
R R R C s R R R C C s R R C s R
V V
R R C s
| |
=
|
\ .

( )
2 3 2
2
2 1 1 2 1 2 1 2 3 1 2
o
i
V R R C s
V R R R R C C s R R R C C s

=
+ + + +

( )
1 2
3 2 3 1 2
2
2 1 1 2
1 1 2
1 2 3 1 2 3 1 2
o
i
C C
s
V R C R CC
R R C C
V R C C
s s
R R R CC R CC
+
| |
=
|
|
+ +
+
\ .
+ +

Si
1 2
C C C = =
3 3
2
2 1
1
2
1 2 3 3
2
2
2
o
i
s
V R R C
R R
V R
s s
R R R C R C
| |
=
|
+
\ .
+ +

( ) ( )
0 0
2 s j j f e t = =

La frecuencia central ser:
2 1 2 1 2
0 0
1 2 3 1 2 1 2 3 1 2
1
2
R R R R
f
R R R C C R R R C C
e
t
+ +
= =

El ancho de banda ser:



El factor de calidad Q = f
0
/ BW

El factor de calidad Q

El Q es la relacin entre la frecuencia central de paso-banda y las frecuencias de
3dB en un circuito paso-banda, como se muestra en la figura 1.6.



Donde:

= frecuencia resonancia
f
1
= frecuencia inferior de 3 dB
f
2
= frecuencia superior de 3 dB

Para el diseo se tendrn en cuenta las siguientes ecuaciones obtenidas para este filtro:

(6)




0
A = Ganancia del filtro


0
e = frecuencia de resonancia

Q= Factor de calidad
3
0
1
1 2
1 2
1 2
2
0
3 1 2
3
0 0
1 1
(1)
2
(2) ' //
1
(3)
'
1
(4)
2 '
(5)
R
A
R
R R
R R R
R R
R R C C
R
Q
R
Q
A
R C
e
e

= =
+
=

=
=

Instrumentos a Utilizar


- Fuente CC

- Generador de seales

- Osciloscopio

- Protoboard

- Condensadores

- Resistencias

- Amplificador operacional LM741

- Alicates

- Tester



























Trabajo de Laboratorio


Segn las ecuaciones de diseo que se obtienen a travs del anlisis terico, disee e
implemente con los valores prcticos mas aproximados el filtro pasa banda activo mostrado en la
figura 1.

Terico:

Las especificaciones inciales de diseo a considerar son las siguientes:

Ganancia de amplitud en resonancia: A=5
Frecuencia de Resonancia: F
0
= 1000Hz
Factor de Calidad: Q=10
Sugerencia: C1=C2=10nf

Ahora a partir de (5) se obtiene

0 0 1
1 1 0 0 1
10
(5) 31.83
5 2 1 10
Q Q
A R K
R C A C K n
e
e t
= = = = O



Luego de (1)

3
0 3 1 0
1
(1) 2 2 31.83 5 318.3
2
R
A R R A K K
R

= = = = O

Cabe destacar que el signo de la ecuacin no influye para el diseo

De (4) se infiere

( )
3 3
2 2
1 318.3
(4) ' 796
2 ' (2 10)
2
R R K
Q R
R
Q
O
= = = = O


Y en (2)

1 2 1
2
1 2 1
' 31.83 796
(2) ' 816
' 31.83 796
R R R R K
R R
R R R R K

= = = = O
+


Las Resistencias para el circuito sern:

1
2
3
31.83
816
318.3
R K
R
R K
= O
= O
= O



Finalmente obtenemos las frecuencias de corte de acuerdo al ancho de banda esperado:




Prctico:

Aproximamos las resistencias a valores comerciales, cercanos al valor calculado
tericamente:

R1 = 32k ;R2 = 820 ;R3 = 330k

Ahora medimos experimentalmente en el circuito, mediante un osciloscopio y buscamos la
frecuencia central variando la frecuencia en el generador de seales entregndonos los siguientes
datos:


Figura 2: Seal de entrada 1,03V
seal de salida 4.57V, esto implica
una ganancia de 4.43 veces.












Luego, de acuerdo al voltaje de salida mximo que encontramos buscamos la frecuencia 1
cuando el voltaje de salida sea un 70.7% del voltaje mximo, disminuyendo la frecuencia del
generador de seales hasta encontrar 3.24 V a la salida, dando como resultado:





Figura 3: imagen de frecuencia de
corte 1.
V
0
= 3.24 V
f
1
= 909,4 Hz














Anlogamente a lo anterior, aumentamos la frecuencia y obtenemos:



Figura 4: imagen de frecuencia de
corte 2.
V
0
= 3.24 V
f
2
= 1010 Hz












Durante la experiencia, generamos la siguiente tabla de comparacin:

Terico Practico
F
0
1 kHz 959.7 Hz
R
1
31.8 k 32 k
R
2
817 820
R
3
318.47 k 330 k
C
1
=C
2
10 nF 10 nF
F
1
951.24 Hz 909.4 Hz
F
2
1051.24 Hz 1010 Hz
Bw 100 Hz 100.6 Hz
A
0
5 4.43
V
0
5 V 4.57 V
V
i
1 V 1.03 V
0.707V
0
3.53 V 3.24 V


De acuerdo a la frecuencias de resonancia y corte , calculamos un factor de calidad practico:




Obtenemos el tercer armnico ingresando una seal cuadrada a una frecuencia de f
0
/3 = 319.7 hz


Figura 5: imagen del tercer
armnico.

V
i
= 1.08 V
V
0
= 2.51 V










Obtenemos el quinto armnico ingresando una seal cuadrada a una frecuencia de f
0
/5 = 191.7 hz












Figura 6: imagen del quinto armnico.

V
i
= 1.08 V
V
0
= 1.75 V













Informe final

En la formula,
0
,
4
( ) ( )
cc
n impar
V
V t sen n t
n
e
t
| |
=
|
\ .

, se puede analizar que lo que va variando es


la amplitud de la seal de salida, manteniendo la frecuencia que acepta el filtro, adems debido al
armnico impar, a medida que va aumentando la ponderacin de las componentes armnicas, la
amplitud de la seal de salida va disminuyendo.


A continuacin comparamos en la tabla 1 el diseo terico (componentes ideales), con los
valores obtenidos en el diseo practico (componentes reales).

Factor Valor Estimado Valor medido Error %
F
o
1[KHz] 959.7[Hz] 4.03%
Q

10 9.54 4.6%
A
o
5 4.43 11.4%
Tabla 1: porcentaje de Error entre valores ideales vs valores prcticos

100
Estimado Medido
Error
Estimado

Вам также может понравиться