0 оценок0% нашли этот документ полезным (0 голосов)
66 просмотров1 830 страниц
The system complies with the standard EN 60950 / IEC 60950. Hazardous voltages are present at the AC power supply lines in this electrical equipment. Failure to observe and follow all installation and safety instructions can result in serious personal injury or property damage. Only trained and qualified personnel may install and maintain the system.
The system complies with the standard EN 60950 / IEC 60950. Hazardous voltages are present at the AC power supply lines in this electrical equipment. Failure to observe and follow all installation and safety instructions can result in serious personal injury or property damage. Only trained and qualified personnel may install and maintain the system.
The system complies with the standard EN 60950 / IEC 60950. Hazardous voltages are present at the AC power supply lines in this electrical equipment. Failure to observe and follow all installation and safety instructions can result in serious personal injury or property damage. Only trained and qualified personnel may install and maintain the system.
CML:BSC A30808-X3247-L230-3-7619 2 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller ! Important Notice on Product Safety DANGER - RISK OF ELECTRICAL SHOCK OR DEATH - FOLLOW ALL INSTALLATION INSTRUCTIONS. The system complies with the standard EN 60950 / IEC 60950. All equipment connected to the system must comply with the applicable safety standards. Hazardous voltages are present at the AC power supply lines in this electrical equipment. Some components may also have high operating temperatures. Failure to observe and follow all installation and safety instructions can result in serious personal injury or property damage. Therefore, only trained and qualified personnel may install and maintain the system. The same text in German: Wichtiger Hinweis zur Produktsicherheit LEBENSGEFAHR - BEACHTEN SIE ALLE INSTALLATIONSHINWEISE. Das Systementspricht den Anforderungen der EN60950 / IEC60950. Alle an das Systemangeschlo- ssenen Gerte mssen die zutreffenden Sicherheitsbestimmungen erfllen. In diesen Anlagen stehen die Netzversorgungsleitungen unter gefhrlicher Spannung. Einige Komponenten knnen auch eine hohe Betriebstemperatur aufweisen. Nichtbeachtung der Installations- und Sicherheitshinweise kann zu schweren Krperverlet- zungen oder Sachschden fhren. Deshalb darf nur geschultes und qualifiziertes Personal das System installieren und warten. Caution: This equipment has been tested and found to comply with EN 301489. Its class of conformity is defined in table A30808-X3247-X910-*-7618, which is shipped with each product. This class also corresponds to the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the relevant standards referenced in the manual Guide to Documentation, may cause harmful interference to radio communications. For system installations it is strictly required to choose all installation sites according to national and local requirements concerning construction rules and static load capacities of buildings and roofs. For all sites, in particular in residential areas it is mandatory to observe all respectively applicable electromagnetic field / force (EMF) limits. Otherwise harmful personal interference is possible. Trademarks: All designations used in this document can be trademarks, the use of which by third parties for their own purposes could violate the rights of their owners. Copyright (C) Siemens AG 2003. Issued by the Information and Communication Mobile Group Hofmannstrae 51 D-81359 Mnchen Technical modifications possible. Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a written contract. A30808-X3247-L230-3-7619 3 Commands Base Station Controller CML:BSC This document consists of a total of 1830 pages. All pages are issue 2. Reason for Update Summary: Third Edition for Release BR7.0 Details: Chapter/Section Reason for Update All New Release BR7.0 Common Edition for BR7.0 and TD2.0 Revised Chapter Issue History Issue Number Date of Issue Reason for Update 1 07.2003 First Edition for New Release BR7.0 2 Prel. 10.2003 Second Edition for BR7.0 and TD2.0 3 12.2003 Third Edition for Release BR7.0 4 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 1.1 Input Handler Application. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 1.2 LMT BSC Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 1.2.1 BSC Containment Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 1.2.2 BTS Equipment and TRAU Containment Sub-Trees. . . . . . . . . . . . . . . . . . 39 1.2.3 Alphabetical List of Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 2 Objects and Commands in Alphabetical Order . . . . . . . . . . . . . . . . . . . . . . 83 ADJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 CREATE ADJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 DELETE ADJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 GET ADJC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 GET ADJC BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 SET ADJC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 ADJC3G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 CREATE ADJC3G. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 DELETE ADJC3G. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 GET ADJC3G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 GET ADJC3G BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 SET ADJC3G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 ADJCTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 CREATE ADJCTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 DELETE ADJCTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 GET ADJCTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 GET ADJCTD BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 SET ADJCTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 AIRTSTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 CREATE AIRTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DELETE AIRTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 GET AIRTSTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 GET AIRTSTD BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 GET AIRTSTD STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 GETRELATIONSHIP AIRTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 GETSUBO AIRTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 LOCK AIRTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 SET AIRTSTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 SHUTDOWN AIRTSTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 UNLOCK AIRTSTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 BSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 GET BSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 GET BSC ALARMSEV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 GET BSC BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 GET BSC CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 GET BSC STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 A30808-X3247-L230-3-7619 5 Commands Base Station Controller CML:BSC GET BSC TIMER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 GETLOCKED BSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127 MEMDUMP BSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127 SET BSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130 BSCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 GET BSCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 GET BSCE ALARMSEV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 GET BSCE REMINV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 GETACTIVEALARMS BSCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 PERFTEST BSCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 SET BSCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 STOPTEST BSCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146 BSCESUDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148 GET BSCESUDB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148 GET BSCESUDB BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 GET BSCESUDB STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 GETINFO BSCESUDB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 BSCESUSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 GET BSCESUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 GET BSCESUSW BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 GET BSCESUSW STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 GETINFO BSCESUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156 BSCETEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160 GET BSCETEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160 BSCOSUDB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162 GET BSCOSUDB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162 GET BSCOSUDB BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163 GETINFO BSCOSUDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164 SAVEDB BSCOSUDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 SET BSCOSUDB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 SETRUNNEW BSCOSUDB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169 BSCOSUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171 GET BSCOSUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171 GET BSCOSUSW BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172 GETINFO BSCOSUSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173 SET BSCOSUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 SETBACKNEW BSCOSUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177 SETRUNBACK BSCOSUSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178 SETRUNNEW BSCOSUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179 BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185 CREATE BTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185 DELETE BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 GET BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 GET BTS BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204 GET BTS CCCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208 GET BTS INTERF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210 GET BTS OPTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210 6 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET BTS STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212 GET BTS TIMER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213 GETINFO BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214 GETRELATIONSHIP BTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219 GETSUBO BTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 LOCK BTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 MONITOR BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 SET BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223 SHUTDOWN BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235 UNLOCK BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236 BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238 CREATE BTSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238 DELETE BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 GET BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 GET BTSM BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243 GET BTSM STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244 GETINFO BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245 GETRELATIONSHIP BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253 GETSUBO BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254 LOCK BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255 SET BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256 SHUTDOWN BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259 UNLOCK BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261 BTSMOSUSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 GET BTSMOSUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 GET BTSMOSUSW BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263 GETINFO BTSMOSUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264 SETRUNBACK BTSMOSUSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265 BTSMTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267 CREATE BTSMTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267 DELETE BTSMTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269 GET BTSMTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270 GET BTSMTD BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272 GET BTSMTD STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273 GETINFO BTSMTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 GETRELATIONSHIP BTSMTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278 GETSUBO BTSMTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279 LOCK BTSMTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280 SET BTSMTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280 SHUTDOWN BTSMTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282 UNLOCK BTSMTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283 BTSMTDOSUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285 GET BTSMTDOSUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285 GET BTSMTDOSUSW BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 286 GETINFO BTSMTDOSUSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287 SETRUNBACK BTSMTDOSUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288 BTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 A30808-X3247-L230-3-7619 7 Commands Base Station Controller CML:BSC CREATE BTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 DELETE BTSTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294 GET BTSTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296 GET BTSTD BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302 GET BTSTD CCCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 305 GET BTSTD OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306 GET BTSTD STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 308 GET BTSTD TIMER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309 GETINFO BTSTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310 GETRELATIONSHIP BTSTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314 GETSUBO BTSTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315 LOCK BTSTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315 SET BTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317 SHUTDOWN BTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 321 UNLOCK BTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322 CBCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324 CREATE CBCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324 DELETE CBCL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325 GET CBCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 326 GET CBCL BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 326 GET CBCL STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 327 GET CBCLX25INFO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 329 GETRELATIONSHIP CBCL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 329 LOCK CBCL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 330 UNLOCK CBCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331 CHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333 CREATE CHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333 DELETE CHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 338 GET CHAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 339 GET CHAN BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 340 GET CHAN STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341 GETRELATIONSHIP CHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342 GETSUBO CHAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343 LOCK CHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343 SET CHAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 345 SHUTDOWN CHAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347 UNLOCK CHAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 349 CPEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350 GET CPEX STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350 GETRELATIONSHIP CPEX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351 GETSUBO CPEX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351 GETTEST CPEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 352 LOCK CPEX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 353 PERFTEST CPEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 354 STOPTEST CPEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 356 UNLOCK CPEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 357 CTRCO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 358 8 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET CTRCO STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 358 GETINFO CTRCO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359 LOCK CTRCO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 361 UNLOCK CTRCO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362 UPLALLCELLTR CTRCO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362 UPLCELLTR CTRCO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363 CTRSCHED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 365 CREATE CTRSCHED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 365 DELETE CTRSCHED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 366 GET CTRSCHED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 367 GET CTRSCHED BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 368 GET CTRSCHED STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 368 LOCK CTRSCHED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 369 SET CTRSCHED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 370 UNLOCK CTRSCHED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 371 DISK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373 FORMAT DISK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373 GET DISK STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374 GETRELATIONSHIP DISK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374 GETSUBO DISK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375 GETTEST DISK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 376 LOCK DISK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377 PERFTEST DISK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 378 STOPTEST DISK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 379 UNLOCK DISK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 381 DK40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 382 GET DK40 STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 382 GETRELATIONSHIP DK40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383 GETSUBO DK40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383 GETTEST DK40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384 LOCK DK40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 385 PERFTEST DK40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 386 STOPTEST DK40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 388 UNLOCK DK40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 389 ENVA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 390 CREATE ENVA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 390 DELETE ENVA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 391 GET ENVA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 391 GET ENVA BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 392 GET ENVA STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 393 LOCK ENVA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 394 SET ENVA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 394 UNLOCK ENVA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 395 EPWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397 CREATE EPWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397 DELETE EPWR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 398 GET EPWR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 399 A30808-X3247-L230-3-7619 9 Commands Base Station Controller CML:BSC GET EPWR STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 399 GETSUBO EPWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400 GETTEST EPWR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 401 LOCK EPWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 402 PERFTEST EPWR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 403 STOPTEST EPWR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405 UNLOCK EPWR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 406 FAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 407 GET FAN STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 407 GETRELATIONSHIP FAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 408 GETSUBO FAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 408 FHSY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 410 CREATE FHSY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 410 DELETE FHSY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 412 GET FHSY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 413 GET FHSY BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 414 SET FHSY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415 FILEHANDLER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 419 COPY FILEHANDLER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 419 CREATEDIR FILEHANDLER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 420 DELETE FILEHANDLER GENFILE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 421 DIR FILEHANDLER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 421 FILECOM FILEHANDLER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 422 FILEDECOM FILEHANDLER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 423 MOVE FILEHANDLER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 424 REMOVEDIR FILEHANDLER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 425 UPLPRLOG FILEHANDLER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 426 FRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 427 CREATE FRL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 427 DELETE FRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 428 GET FRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 429 GET FRL BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 430 GET FRL STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 431 GETINFO FRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 432 GETRELATIONSHIP FRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 434 GETSUBO FRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 434 LOCK FRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 435 SET FRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 436 UNLOCK FRL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 437 HAND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 439 GET HAND. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 439 GET HAND BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 445 GET HAND DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 451 SET HAND. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 452 HANDTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 459 GET HANDTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 459 GET HANDTD BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 461 10 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SET HANDTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 462 IPLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 466 CREATE IPLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 466 DELETE IPLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 467 GET IPLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 468 GET IPLI BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 468 GET IPLI STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 469 GETINFO IPLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 470 GETRELATIONSHIP IPLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 472 PING IPLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 473 SET IPLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 474 IXLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 475 GET IXLT STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 475 GETINFO IXLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 476 GETRELATIONSHIP IXLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 478 GETTEST IXLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 478 LOCK IXLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 479 PERFTEST IXLT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 480 STOPTEST IXLT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 482 UNLOCK IXLT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 484 LICD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 485 CREATE LICD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 485 DELETE LICD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 486 GET LICD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 487 GET LICD BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 488 GET LICD STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 489 GETINFO LICD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 489 GETRELATIONSHIP LICD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 492 GETSUBO LICD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 493 GETTEST LICD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 494 LOCK LICD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 495 PERFTEST LICD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 496 SET LICD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 497 STOPTEST LICD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 498 UNLOCK LICD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 499 LICDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 501 CREATE LICDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 501 DELETE LICDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 502 GET LICDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 503 GET LICDS STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 503 GETRELATIONSHIP LICDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 504 GETSUBO LICDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 505 GETTEST LICDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 506 LOCK LICDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 507 PERFTEST LICDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 508 STOPTEST LICDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 509 UNLOCK LICDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 511 A30808-X3247-L230-3-7619 11 Commands Base Station Controller CML:BSC LMT-INTERNAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 512 ECHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 512 EXEC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 512 SET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 513 LPDLM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 514 CREATE LPDLM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 514 DELETE LPDLM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 515 GET LPDLM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 516 GET LPDLM BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 517 GET LPDLM STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 517 GETINFO LPDLM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 518 GETRELATIONSHIP LPDLM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 521 GETSUBO LPDLM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 522 SET LPDLM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 523 LPDLMTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 524 CREATE LPDLMTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 524 DELETE LPDLMTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 525 GET LPDLMTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 526 GET LPDLMTD BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 527 GET LPDLMTD STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 527 GETINFO LPDLMTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 528 GETRELATIONSHIP LPDLMTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 530 GETSUBO LPDLMTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 531 LPDLR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 533 GET LPDLR STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 533 GETINFO LPDLR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 534 GETRELATIONSHIP LPDLR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 536 GETSUBO LPDLR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 537 LPDLRTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 539 GET LPDLRTD STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 539 GETINFO LPDLRTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 540 GETRELATIONSHIP LPDLRTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 541 GETSUBO LPDLRTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 543 LPDLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 544 CREATE LPDLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 544 DELETE LPDLS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 545 GET LPDLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 546 GET LPDLS BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 547 GET LPDLS STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 547 GETINFO LPDLS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 548 GETRELATIONSHIP LPDLS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 551 GETSUBO LPDLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 552 SET LPDLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 552 MEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 554 GET MEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 554 GET MEL BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 555 SET MEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 555 12 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller MEMT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 557 GET MEMT STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 557 GETRELATIONSHIP MEMT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 558 GETSUBO MEMT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 558 GETTEST MEMT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 559 LOCK MEMT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 560 PERFTEST MEMT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 561 STOPTEST MEMT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 563 SWITCH MEMT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 564 UNLOCK MEMT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 565 MPCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 566 GET MPCC STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 566 GETINFO MPCC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 567 GETRELATIONSHIP MPCC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 569 GETSUBO MPCC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 570 GETTEST MPCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 571 LOCK MPCC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 572 PERFTEST MPCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 573 STOPTEST MPCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 575 SWITCH MPCC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 576 UNLOCK MPCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 577 NEYESUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 579 GET NEYESUSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 579 GET NEYESUSW BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 580 GET NEYESUSW STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 581 GETINFO NEYESUSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 582 NEDOWNLOAD NEYESUSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 584 NEDOWNLOADABO NEYESUSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 585 NSVC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 587 CREATE NSVC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 587 DELETE NSVC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 588 GET NSVC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 589 GET NSVC BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 589 GET NSVC STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 590 GETINFO NSVC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 591 GETRELATIONSHIP NSVC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 593 GETSUBO NSVC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 593 LOCK NSVC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 594 UNLOCK NSVC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 595 NTW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 596 FORCSYNC NTW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 596 GET NTW STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 597 GETRELATIONSHIP NTW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 597 GETSUBO NTW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 598 GETSYNC NTW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 599 GETTEST NTW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600 LOCK NTW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 601 A30808-X3247-L230-3-7619 13 Commands Base Station Controller CML:BSC PERFTEST NTW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 602 STOPTEST NTW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 604 SWITCH NTW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 605 UNLOCK NTW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 606 UPDATETUNE NTW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 607 NUC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 609 CREATE NUC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 609 DELETE NUC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 610 GET NUC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 611 GET NUC BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 612 GET NUC STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 612 GETRELATIONSHIP NUC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 613 OMAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 615 CREATE OMAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 615 DELETE OMAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 616 GET OMAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 617 GET OMAL BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 617 GET OMAL STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 618 GET OMAL X25INFO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 619 GETRELATIONSHIP OMAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 620 GETSUBO OMAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 621 SET OMAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 622 OPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 623 CREATE OPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 623 DELETE OPC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 626 GET OPC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 627 GET OPC BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 630 GET OPC MTL2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 631 GET OPC MTL3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 632 GETINFO OPC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 633 SET OPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 635 PCMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 639 CREATE PCMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 639 DELETE PCMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 641 GET PCMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 642 GET PCMA BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 643 GET PCMA PCM24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 643 GET PCMA PCM30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 644 GET PCMA STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 645 GETINFO PCMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 646 GETRELATIONSHIP PCMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 647 GETSUBO PCMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 648 LOCK PCMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 649 SHUTDOWN PCMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 650 UNLOCK PCMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 651 PCMB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 652 CREATE PCMB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 652 14 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DELETE PCMB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 654 GET PCMB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 655 GET PCMB BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 656 GET PCMB PCM24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 657 GET PCMB PCM30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 657 GET PCMB STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 658 GETINFO PCMB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 659 GETREDSTAT PCMB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 662 GETRELATIONSHIP PCMB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 663 GETSUBO PCMB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 664 LOCK PCMB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 665 SET PCMB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 666 UNLOCK PCMB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 667 PCMG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 669 CREATE PCMG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 669 DELETE PCMG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 670 GET PCMG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 671 GET PCMG BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 672 GET PCMG PCM24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 673 GET PCMG PCM30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 673 GET PCMG STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 674 GETINFO PCMG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 675 GETRELATIONSHIP PCMG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 678 GETSUBO PCMG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 680 LOCK PCMG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 680 SET PCMG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 681 UNLOCK PCMG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 682 PCMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 684 CREATE PCMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 684 DELETE PCMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 686 GET PCMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 687 GET PCMS BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 688 GET PCMS PCM24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 688 GET PCMS PCM30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 689 GET PCMS STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 690 GETINFO PCMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 691 GETREDSTAT PCMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 694 GETRELATIONSHIP PCMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 695 GETSUBO PCMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 696 LOCK PCMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 696 SET PCMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 697 UNLOCK PCMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 698 PCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700 CREATE PCU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700 DELETE PCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 703 GET PCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 705 GET PCU BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 706 A30808-X3247-L230-3-7619 15 Commands Base Station Controller CML:BSC GET PCU STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 708 GETINFO PCU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 708 GETRELATIONSHIP PCU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 711 GETSUBO PCU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 712 LOCK PCU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 713 SET PCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 714 UNLOCK PCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 715 PCUTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 717 CREATE PCUTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 717 DELETE PCUTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 719 GET PCUTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 720 GET PCUTD BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 721 GET PCUTD STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 723 GETINFO PCUTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 723 GETRELATIONSHIP PCUTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 726 GETSUBO PCUTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 727 LOCK PCUTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 729 SET PCUTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 730 UNLOCK PCUTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 731 PPCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 733 GET PPCC STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 733 GETINFO PPCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 734 GETRELATIONSHIP PPCC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 736 GETSUBO PPCC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 736 GETTEST PPCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 737 LOCK PPCC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 738 PERFTEST PPCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 739 STOPTEST PPCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 741 UNLOCK PPCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 742 PPCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 743 GET PPCU STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 743 GETINFO PPCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 744 GETRELATIONSHIP PPCU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 746 GETSUBO PPCU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 747 GETTEST PPCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 747 LOCK PPCU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 749 PERFTEST PPCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 750 STOPTEST PPCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 751 SWITCH PPCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 752 UNLOCK PPCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 753 PPLD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 755 CREATE PPLD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 755 DELETE PPLD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 756 GET PPLD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 757 GET PPLD STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 758 GETINFO PPLD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 759 GETRELATIONSHIP PPLD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 761 16 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETSUBO PPLD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 762 GETTEST PPLD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 763 LOCK PPLD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 764 PERFTEST PPLD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 765 STOPTEST PPLD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 767 UNLOCK PPLD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 768 PPXL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 769 GET PPXL STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 769 GETINFO PPXL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 770 GETRELATIONSHIP PPXL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 774 GETSUBO PPXL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 775 GETTEST PPXL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 776 LOCK PPXL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 777 PERFTEST PPXL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 778 STOPTEST PPXL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 779 UNLOCK PPXL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 781 PPXP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 782 GET PPXP STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 782 GETINFO PPXP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 783 GETRELATIONSHIP PPXP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 785 GETSUBO PPXP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 786 GETTEST PPXP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 787 LOCK PPXP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 788 PERFTEST PPXP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 789 STOPTEST PPXP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 790 UNLOCK PPXP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 792 PPXT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 793 CREATE PPXT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 793 DELETE PPXT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 794 GET PPXT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 795 GET PPXT STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 795 GETINFO PPXT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 797 GETRELATIONSHIP PPXT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800 GETSUBO PPXT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800 GETTEST PPXT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 801 LOCK PPXT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 802 PERFTEST PPXT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 803 STOPTEST PPXT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 806 UNLOCK PPXT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 807 PPXU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 808 GET PPXU STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 808 GETINFO PPXU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 809 GETRELATIONSHIP PPXU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 811 GETSUBO PPXU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 812 GETTEST PPXU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 813 LOCK PPXU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 814 PERFTEST PPXU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 815 A30808-X3247-L230-3-7619 17 Commands Base Station Controller CML:BSC STOPTEST PPXU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 816 UNLOCK PPXU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 818 PTPPKF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 819 CREATE PTPPKF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 819 DELETE PTPPKF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 824 GET PTPPKF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 826 GET PTPPKF BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 830 GET PTPPKF STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 833 GETINFO PTPPKF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 834 GETRELATIONSHIP PTPPKF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 836 GETSUBO PTPPKF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 837 LOCK PTPPKF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 838 SET PTPPKF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 840 UNLOCK PTPPKF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 845 PTPPKFTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 846 CREATE PTPPKFTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 846 DELETE PTPPKFTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 847 GET PTPPKFTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 848 GET PTPPKFTD BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 849 GET PTPPKFTD STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 851 GETINFO PTPPKFTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 852 GETRELATIONSHIP PTPPKFTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 854 GETSUBO PTPPKFTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 855 LOCK PTPPKFTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 855 SET PTPPKFTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 856 UNLOCK PTPPKFTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 857 PWRC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 859 GET PWRC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 859 GET PWRC BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 864 SET PWRC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 870 PWRCTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 873 GET PWRCTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 873 GET PWRCTD BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 875 SET PWRCTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 876 PWRD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 878 GET PWRD STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 878 GETRELATIONSHIP PWRD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 879 GETSUBO PWRD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 879 GETTEST PWRD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 880 LOCK PWRD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 881 PERFTEST PWRD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 882 STOPTEST PWRD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 884 UNLOCK PWRD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 885 REMINV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 886 ALIGN REMINV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 886 DNLIDFD REMINV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 887 GET REMINV STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 888 18 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller LOCK REMINV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 889 UNLOCK REMINV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 890 UPLCIDF REMINV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 891 UPLLIDF REMINV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 893 RFLOOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 895 CREATE RFLOOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 895 DELETE RFLOOP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 896 GET RFLOOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 896 GET RFLOOP BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 897 GET RFLOOP STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 898 LOCK RFLOOP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 899 SET RFLOOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 900 UNLOCK RFLOOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 901 UPLOADREQ RFLOOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 901 RSUDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 903 CREATE RSUDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 903 DELETE RSUDB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 904 GET RSUDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 905 GET RSUDB BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 906 GET RSUDB STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 907 SET RSUDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 908 UPLDFILE RSUDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 909 RSUEXE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 911 CREATE RSUEXE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 911 DELETE RSUEXE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 912 GET RSUEXE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 913 GET RSUEXE BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 914 GET RSUEXE STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 915 RSUPCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 917 CREATE RSUPCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 917 DELETE RSUPCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 919 GET RSUPCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 920 GET RSUPCH BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 921 GET RSUPCH STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 922 LOADPATCH RSUPCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 923 SET RSUPCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 924 UNLOADPCH RSUPCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 926 RSUSWLH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 928 CREATE RSUSWLH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 928 DELETE RSUSWLH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 929 GET RSUSWLH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 930 GET RSUSWLH BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 931 GET RSUSWLH STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 932 SET RSUSWLH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 933 SCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 935 CREATE SCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 935 DELETE SCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 938 A30808-X3247-L230-3-7619 19 Commands Base Station Controller CML:BSC GET SCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 938 GET SCA BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 941 GET SCA EICM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 942 GET SCA NMDL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 943 GET SCA STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 945 LOCK SCA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 945 SET SCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 946 UNLOCK SCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 948 UPLOADREQ SCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 948 SCANAIRTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 950 ADD SCANAIRTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 950 CREATE SCANAIRTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 951 DELETE SCANAIRTSTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 953 GET SCANAIRTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 955 GET SCANAIRTSTD BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 956 GET SCANAIRTSTD STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 957 LOCK SCANAIRTSTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 958 REMOVE SCANAIRTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 959 SET SCANAIRTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 960 UNLOCK SCANAIRTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 962 SCANBSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 964 ACTIVATE SCANBSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 964 ADD SCANBSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 965 CREATE SCANBSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 966 DELETE SCANBSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 967 GET SCANBSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 968 GET SCANBSC BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 969 GET SCANBSC STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 970 LOCK SCANBSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 971 REMOVE SCANBSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 972 SET SCANBSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 972 UNLOCK SCANBSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 974 SCANBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 975 ADD SCANBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 975 CREATE SCANBTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 976 DELETE SCANBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 977 GET SCANBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 978 GET SCANBTS BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 979 GET SCANBTS STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 980 LOCK SCANBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 981 REMOVE SCANBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 982 SET SCANBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 983 UNLOCK SCANBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 984 SCANBTSABISTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 986 ADD SCANBTSABISTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 986 CREATE SCANBTSABISTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 987 DELETE SCANBTSABISTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 988 20 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET SCANBTSABISTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 989 GET SCANBTSABISTD BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 990 GET SCANBTSABISTD STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 991 LOCK SCANBTSABISTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 992 REMOVE SCANBTSABISTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 993 SET SCANBTSABISTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 994 UNLOCK SCANBTSABISTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 995 SCANBTSE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 997 ADD SCANBTSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 997 CREATE SCANBTSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 998 DELETE SCANBTSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 999 GET SCANBTSE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000 GET SCANBTSE BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1001 GET SCANBTSE STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1002 LOCK SCANBTSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1003 REMOVE SCANBTSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1004 SET SCANBTSE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1005 UNLOCK SCANBTSE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1006 SCANBTSIHO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1008 ADD SCANBTSIHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1008 CREATE SCANBTSIHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1009 DELETE SCANBTSIHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1010 GET SCANBTSIHO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1011 GET SCANBTSIHO BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1012 GET SCANBTSIHO STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1013 LOCK SCANBTSIHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1014 REMOVE SCANBTSIHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1015 SET SCANBTSIHO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1016 UNLOCK SCANBTSIHO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1017 SCANBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1019 ADD SCANBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1019 CREATE SCANBTSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1020 DELETE SCANBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1021 GET SCANBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1022 GET SCANBTSM BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1023 GET SCANBTSM STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1024 LOCK SCANBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1025 REMOVE SCANBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1027 SET SCANBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1028 UNLOCK SCANBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1029 SCANBTSMTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1031 ADD SCANBTSMTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1031 CREATE SCANBTSMTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1032 DELETE SCANBTSMTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1034 GETSCANBTSMTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1035 GET SCANBTSMTD BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1036 GET SCANBTSMTD STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1037 A30808-X3247-L230-3-7619 21 Commands Base Station Controller CML:BSC LOCK SCANBTSMTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1037 REMOVE SCANBTSMTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1038 SET SCANBTSMTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1040 UNLOCK SCANBTSMTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1041 SCANBTSOHOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1043 ADD SCANBTSOHOI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1043 CREATE SCANBTSOHOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1044 DELETE SCANBTSOHOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1046 GET SCANBTSOHOI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1047 GET SCANBTSOHOI BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1048 GET SCANBTSOHOI STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1049 LOCK SCANBTSOHOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1049 REMOVE SCANBTSOHOI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1050 SET SCANBTSOHOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1051 UNLOCK SCANBTSOHOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1053 SCANBTSOHON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1054 ADD SCANBTSOHON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1054 CREATE SCANBTSOHON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1055 DELETE SCANBTSOHON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1057 GET SCANBTSOHON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1058 GET SCANBTSOHON BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1059 GET SCANBTSOHON STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1060 LOCK SCANBTSOHON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1060 REMOVE SCANBTSOHON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1061 SET SCANBTSOHON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1062 UNLOCK SCANBTSOHON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1064 SCANBTSOHOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1065 ADD SCANBTSOHOS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1065 CREATE SCANBTSOHOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1066 DELETE SCANBTSOHOS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1067 GET SCANBTSOHOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1068 GET SCANBTSOHOS BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1069 GET SCANBTSOHOS STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1070 LOCK SCANBTSOHOS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1071 REMOVE SCANBTSOHOS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1072 SET SCANBTSOHOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1073 UNLOCK SCANBTSOHOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1074 SCANBTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1076 ADD SCANBTSTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1076 CREATE SCANBTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1077 DELETE SCANBTSTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1079 GET SCANBTSTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1080 GET SCANBTSTD BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1081 GET SCANBTSTD STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1082 LOCK SCANBTSTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1082 REMOVE SCANBTSTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1083 SET SCANBTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1084 22 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller UNLOCK SCANBTSTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1086 SCANBTSTDIHDO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1088 ADD SCANBTSTDIHDO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1088 CREATE SCANBTSTDIHDO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1089 DELETE SCANBTSTDIHDO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1091 GET SCANBTSTDIHDO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1092 GET SCANBTSTDIHDO BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1093 GET SCANBTSTDIHDO STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1094 LOCK SCANBTSTDIHDO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1094 REMOVE SCANBTSTDIHDO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1095 SET SCANBTSTDIHDO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1096 UNLOCK SCANBTSTDIHDO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1098 SCANBTSTDOHDOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1099 ADD SCANBTSTDOHDOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1099 CREATE SCANBTSTDOHDOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1100 DELETE SCANBTSTDOHDOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1103 GET SCANBTSTDOHDOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1104 GET SCANBTSTDOHDOI BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1105 GET SCANBTSTDOHDOI STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1106 LOCK SCANBTSTDOHDOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1106 REMOVE SCANBTSTDOHDOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1107 SET SCANBTSTDOHDOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1108 UNLOCK SCANBTSTDOHDOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1110 SCANBTSTDOHDON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1111 ADD SCANBTSTDOHDON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1111 CREATE SCANBTSTDOHDON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1112 DELETE SCANBTSTDOHDON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1114 GET SCANBTSTDOHON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1116 GET SCANBTSTDOHDON BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1117 GET SCANBTSTDOHDON STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1118 LOCK SCANBTSTDOHDON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1118 REMOVE SCANBTSTDOHDON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1119 SET SCANBTSTDOHDON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1120 UNLOCK SCANBTSTDOHDON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1122 SCANCHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1124 ADD SCANCHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1124 CREATE SCANCHAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1125 DELETE SCANCHAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1126 GET SCANCHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1127 GET SCANCHAN BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1128 GET SCANCHAN STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1129 LOCK SCANCHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1130 REMOVE SCANCHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1131 SET SCANCHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1132 UNLOCK SCANCHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1133 SCANCO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1135 GETINFO SCANCO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1135 A30808-X3247-L230-3-7619 23 Commands Base Station Controller CML:BSC UPLMEAS SCANCO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1137 SCANCTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1139 ADD SCANCTRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1139 CREATE SCANCTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1140 DELETE SCANCTRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1141 GET SCANCTRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1142 GET SCANCTRX BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1143 GET SCANCTRX STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1144 LOCK SCANCTRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1145 REMOVE SCANCTRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1145 SET SCANCTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1146 UNLOCK SCANCTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1148 SCANFBTSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1149 ADD SCANFBTSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1149 CREATE SCANFBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1150 DELETE SCANFBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1151 GET SCANFBTSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1152 GET SCANFBTSM BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1153 LOCK SCANFBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1154 REMOVE SCANFBTSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1155 SET SCANFBTSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1156 UNLOCK SCANFBTSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1158 SCANGPRS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1159 ADD SCANGPRS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1159 CREATE SCANGPRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1160 DELETE SCANGPRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1161 GET SCANGPRS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1162 GET SCANGPRS BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1163 GET SCANGPRS STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1164 LOCK SCANGPRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1165 REMOVE SCANGPRS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1166 SET SCANGPRS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1167 UNLOCK SCANGPRS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1168 SCANGPRSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1170 ADD SCANGPRSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1170 CREATE SCANGPRSTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1171 DELETE SCANGPRSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1173 GET SCANGPRSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1174 GET SCANGPRSTDTD BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1175 GET SCANGPRSTD STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1176 LOCK SCANGPRSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1176 REMOVE SCANGPRSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1177 SET SCANGPRSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1178 UNLOCK SCANGPRSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1180 SCANSS7L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1181 ACTIVATE SCANSS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1181 ADD SCANSS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1182 24 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller CREATE SCANSS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1183 DELETE SCANSS7L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1184 GET SCANSS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1185 GET SCANSS7L BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1186 GET SCANSS7L STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1187 LOCK SCANSS7L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1188 REMOVE SCANSS7L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1189 SET SCANSS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1190 UNLOCK SCANSS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1191 SCANTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1193 ADD SCANTRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1193 CREATE SCANTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1194 DELETE SCANTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1195 GET SCANTRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1196 GET SCANTRX BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1197 GET SCANTRX STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1198 LOCK SCANTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1199 REMOVE SCANTRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200 SET SCANTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1201 UNLOCK SCANTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1202 SCANTRXABISTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1204 ADD SCANTRXABISTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1204 CREATE SCANTRXABISTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1205 DELETE SCANTRXABISTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1206 GET SCANTRXABISTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1207 GET SCANTRXABISTD BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1208 GET SCANTRXABISTD STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1209 LOCK SCANTRXABISTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1210 REMOVE SCANTRXABISTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1211 SET SCANTRXABISTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1212 UNLOCK SCANTRXABISTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1213 SCANTRXTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1215 ADD SCANTRXTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1215 CREATE SCANTRXTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1216 DELETE SCANTRXTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1217 GET SCANTRXTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1218 GET SCANTRXTD BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1219 GET SCANTRXTD STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1220 LOCK SCANTRXTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1221 REMOVE SCANTRXTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1222 SET SCANTRXTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1222 UNLOCK SCANTRXTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1224 SOFTWARE-MANAGEMENT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1227 DNLFILE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1227 LOADMPCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1228 UPLBTSLOG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1229 UPLBTSTDLOG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1230 A30808-X3247-L230-3-7619 25 Commands Base Station Controller CML:BSC UPLFILE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1231 UPLTRAULOG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1232 SS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1234 CREATE SS7L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1234 DELETE SS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1235 GET SS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1236 GET SS7L BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1237 GET SS7L STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1238 GETRELATIONSHIP SS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1239 GETSUBO SS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1239 INHIBIT SS7L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1240 LOCK SS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1241 TESTLINK SS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1242 UNINHIBIT SS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1243 UNLOCK SS7L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1244 SS7S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1245 GET SS7S STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1245 GETSUBO SS7S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1246 SUBTSLB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1247 CREATE SUBTSLB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1247 DELETE SUBTSLB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1248 GET SUBTSLB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1249 GET SUBTSLB BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1250 GET SUBTSLB STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1250 LOCK SUBTSLB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1251 SHUTDOWN SUBTSLB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1252 UNLOCK SUBTSLB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1253 SWIBEAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1254 CREATE SWIBEAM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1254 DELETE SWIBEAM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1255 GET SWIBEAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1256 GET SWIBEAM BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1257 GET SWIBEAM CSSERV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1258 SET SWIBEAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1259 SYNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1261 CREATE SYNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1261 DELETE SYNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1262 GET SYNC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1262 GET SYNC BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1263 GET SYNC STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1264 GETRELATIONSHIP SYNC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1265 GETSUBO SYNC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1265 LOCK SYNC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1266 UNLOCK SYNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1267 SYNCO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1269 GETINFO SYNCO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1269 SYNE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1273 26 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller CREATE SYNE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1273 DELETE SYNE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1274 FREQMEAS SYNE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1274 GET SYNE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1275 GET SYNE STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1276 LOCK SYNE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1277 UNLOCK SYNE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1278 SYSINIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1279 SYSINIT SYSINIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1279 TDCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1281 CREATE TDCU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1281 DELETE TDCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1282 GET TDCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1283 GET TDCU STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1284 GETINFO TDCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1284 GETRELATIONSHIP TDCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1286 GETSUBO TDCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1287 LOCK TDCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1289 SHUTDOWN TDCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1289 UNLOCK TDCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1291 TDPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1292 GET TDPC STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1292 GETINFO TDPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1293 GETRELATIONSHIP TDPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1295 GETSUBO TDPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1296 GETTEST TDPC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1297 LOCK TDPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1298 PERFTEST TDPC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1299 STOPTEST TDPC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1301 SWITCH TDPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1302 UNLOCK TDPC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1303 TGTBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1305 CREATE TGTBTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1305 DELETE TGTBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1308 GET TGTBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1310 GET TGTBTS BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1311 SET TGTBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1311 TGTBTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1316 CREATE TGTBTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1316 DELETE TGTBTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1317 GET TGTBTSTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1318 GET TGTBTSTD BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1319 SET TGTBTSTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1320 TGTFDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1322 CREATE TGTFDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1322 DELETE TGTFDD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1323 GET TGTFDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1324 A30808-X3247-L230-3-7619 27 Commands Base Station Controller CML:BSC GET TGTFDD BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1325 SET TGTFDD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1325 TGTPTPPKF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1327 CREATE TGTPTPPKF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1327 DELETE TGTPTPPKF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1328 GET TGTPTPPKF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1329 GET TGTPTPPKF BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1330 SET TGTPTPPKF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1330 TGTTDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1332 CREATE TGTTDD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1332 DELETE TGTTDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1333 GET TGTTDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1333 GET TGTTDD BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1334 SET TGTTDD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1335 TRACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1337 CREATE TRACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1337 DELETE TRACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1337 GET TRACE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1338 GET TRACE BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1339 GET TRACE STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1340 GETINFO TRACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1340 LOCK TRACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1342 SHUTDOWN TRACE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1343 UNLOCK TRACE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1345 UPLALLIMSITR TRACE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1345 UPLIMSITR TRACE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1346 TRAU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1348 CREATE TRAU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1348 DELETE TRAU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1349 GET TRAU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1350 GET TRAU BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1351 GET TRAU STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1352 GET TRAU TIMER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1352 GETINFO TRAU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1353 GETRELATIONSHIP TRAU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1358 GETSUBO TRAU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1359 LOCK TRAU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1360 SET TRAU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1361 SHUTDOWN TRAU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1362 UNLOCK TRAU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1363 TRAUOSUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1365 GET TRAUOSUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1365 GET TRAUOSUSW BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1366 GETINFO TRAUOSUSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1367 SETRUNBACK TRAUOSUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1368 TRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1370 CREATE TRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1370 28 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DELETE TRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1373 GET TRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1374 GET TRX BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1375 GET TRX STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1376 GETINFO TRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1377 GETRELATIONSHIP TRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1379 GETSUBO TRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1380 LOCK TRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1381 SET TRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1382 SHUTDOWN TRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1385 UNLOCK TRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1387 TRXTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1388 CREATE TRXTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1388 DELETE TRXTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1390 GET TRXTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1391 GET TRXTD BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1391 GET TRXTD STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1393 GETINFO TRXTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1394 GETRELATIONSHIP TRXTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1396 GETSUBO TRXTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1397 LOCK TRXTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1397 SET TRXTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1398 SHUTDOWN TRXTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1399 UNLOCK TRXTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1402 TSLA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1403 GET TSLA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1403 GET TSLA BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1404 GET TSLA STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1404 GETRELATIONSHIP TSLA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1405 GETSUBO TSLA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1406 LOCK TSLA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1407 SET TSLA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1408 SHUTDOWN TSLA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1409 UNLOCK TSLA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1410 TSLB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1411 GET TSLB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1411 X25A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1413 CREATE X25A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1413 DELETE X25A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1414 GET X25A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1415 GET X25A BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1416 GET X25A STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1417 GETINFO X25A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1419 GETRELATIONSHIP X25A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1422 SET X25A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1423 X25D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1425 CREATE X25D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1425 A30808-X3247-L230-3-7619 29 Commands Base Station Controller CML:BSC DELETE X25D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1426 GET X25D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1428 GET X25D BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1429 GET X25D STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1430 GETINFO X25D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1431 GETRELATIONSHIP X25D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1434 SET X25D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1435 3 BTS and TRAU Objects and Commands . . . . . . . . . . . . . . . . . . . . . . . . 1437 BTSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1437 BTSEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1443 BTSEPICO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1450 BTSEEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1454 BTSEXS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1458 BTSEC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1461 TRAUE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1467 4 Parameters/Attributes in Alphabetical Order. . . . . . . . . . . . . . . . . . . . . . 1469 ABISCH - GTXINT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1469 HAGSMTOTDSCDMA - OVLSTTHR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1575 PATHNAME - X121ADDR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1657 5 Appendix A: ME-Address Value List . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1779 6 Appendix B: Special Parameter Values . . . . . . . . . . . . . . . . . . . . . . . . . 1783 Special Parameter Values - Group 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1786 Special Parameter Values - Group 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1805 Special Parameter Values - Group 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1807 Special Parameter Values - Group 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1809 Special Parameter Values - Group 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1812 Special Parameter Values - Group 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1817 Special Parameter Values - Group 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1819 Special Parameter Values - Group 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1824 Special parameters values - Group 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1826 Special parameters values - Group 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1827 7 Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1829 30 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller A30808-X3247-L230-3-7619 31 Commands Base Station Controller CML:BSC Illustrations Fig. 1.1 First Panel of the Input Handler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Fig. 1.2 Multiversion containment sub-trees . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Fig. 1.3 Second Panel of the Input Handler . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Fig. 1.4 Tree-lined Command Viewer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Fig. 1.5 BSC containment tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Fig. 1.6 BTSE containment sub-tree. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Fig. 1.7 BTSEP containment sub-tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Fig. 1.8 BTSEPICO containment sub-tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Fig. 1.9 BTSEEM containment sub-tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Fig. 1.10 BTSEXS containment sub-tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Fig. 1.11 BTSEC containment sub-tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Fig. 1.12 TRAUE containment sub-tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 32 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Tables Tab. 2.1 Incompatible test object . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 Tab. 2.2 Status of attribute handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328 Tab. 2.3 Operational state handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328 Tab. 2.4 Congestion and Flow Control Thresholds. . . . . . . . . . . . . . . . . . . . . . . 624 Tab. 2.5 Congestion and Flow Control Thresholds. . . . . . . . . . . . . . . . . . . . . . . 636 Tab. 2.6 BAND and SYSID relation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 936 Tab. 2.7 Status Attributes Handling of GET X25A STAT . . . . . . . . . . . . . . . . . 1418 Tab. 2.8 Enable/Disable X25A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1418 Tab. 2.9 Status Attributes Handling of GET X25D STAT . . . . . . . . . . . . . . . . . 1431 Tab. 2.10 Enable/Disable X25D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1431 Tab. 6.1 Frequency values for P-GSM 900. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1786 Tab. 6.2 Frequency values for E-GSM 900 (from 0 to 124) . . . . . . . . . . . . . . . 1788 Tab. 6.3 Frequency values for E-GSM 900 (from 975 to 1023) . . . . . . . . . . . . 1790 Tab. 6.4 Frequency values for DCS 1800. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1791 Tab. 6.5 Frequency values for GSM-R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1797 Tab. 6.6 Frequency values for PCS 1900. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1797 Tab. 6.7 Frequency values for GSM 850 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1802 Tab. 6.8 Values for received signal threshold. . . . . . . . . . . . . . . . . . . . . . . . . . 1805 Tab. 6.9 Relationship between Signal Quality and BER. . . . . . . . . . . . . . . . . . 1808 Tab. 6.10 Values for GSM and R-GSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1809 Tab. 6.11 Values for DCS 1800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1809 Tab. 6.12 Values for PCS 1900 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1810 Tab. 6.13 Values for UMTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1811 Tab. 6.14 Circuit Pool Coding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1812 Tab. 6.15 Conversion of RXQUAL to C/I for settings related to AMR HO and PWRC parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1817 Tab. 6.16 Correspondence between service dependent and service independent attributes (SGXHOPAR, X =1..6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1820 Tab. 6.17 Correspondence between service dependent and service independent attributes (SGXHOPAR, X = 7, 8, 9, 10) . . . . . . . . . . . . . . . . . . . . . . . 1821 Tab. 6.18 Correspondence between service dependent and service independent attributes (SGXHOPAR, X = 11, 12) . . . . . . . . . . . . . . . . . . . . . . . . . . 1821 Tab. 6.19 Correspondence between service dependent and service independent attributes (SGXHOPAR, X = 13, 14) . . . . . . . . . . . . . . . . . . . . . . . . . . 1822 Tab. 6.20 Correspondence between service dependent and service independent attributes (SGXPCPAR, X = 1..10) . . . . . . . . . . . . . . . . . . . . . . . . . . . 1822 Tab. 6.21 Correspondence between service dependent and service independent attributes (SGXPCPAR, X = 11..14) . . . . . . . . . . . . . . . . . . . . . . . . . . 1823 Tab. 6.22 Occupation of the Frequency Bands for the TD-SCDMA . . . . . . . . . . 1826 Tab. 6.23 Relationship between Signal Quality and BER. . . . . . . . . . . . . . . . . . 1827 A30808-X3247-L230-3-7619 33 Commands Base Station Controller CML:BSC 1 Introduction In the CML:BSC document the commands are described in Alphabetical order of the Managed Object. Described commands can be executed by the operator after connecting the Local Maintenance Terminal (LMT) to the BSC network element. For each command, after the command syntax, the following sections are inserted: Command Tree: This field shows the path on the LMT tree to select the related command. Applicability: This field shows the NE phase and the visibility level. The visibility level associated with a user identification "user_id" and password. Four levels of visibility (0-3) are provided: each level gives the user different access levels to the system features and the higher number of operations to be performed. Visibility level management is not yet activated. Therefore all the access levels are allowed to the LMT user. Command Description: This field explains the function of the command transmitted by the LMT to the BSC (when and why it is used, for which operation task). System Responses: They are response messages sent as acknowledgment for completion of the input commands or they contain information requested by the user. The typical structure of the response messages contains: the date and time, the command line, the system response. The response messages can be either normal (successful) or error messages. In such a case they contain the reason of the failure. Short system messages, such as indication of system loading/downloading functions in progress, are reported in the information line of LMT screen. Application Guidelines: They are warnings given when using this command or information related to the environment in which the command is submitted. Example of Command Execution: It is an example on how to enter the command with its parameters and their relevant values. ! Use of compatible Software Version: in order to use the LMT correctly, the LMT soft- ware version and the others network elements software version, such as BSC, should be aligned as described in the Release Note. 34 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 1.1 Input Handler Application Input Handler is the graphical user interface, activated under control of the Dashboard, which performs the command interaction with the network element. The Input Handler enables the user to navigate the object containment tree of the network element and select a specific command from a list of available ones. By using the Input Handler the user can: acquire commands, actions or scripts, send messages containing commands to the network element, have script/commands translation services, store issued commands send to the network element. After the connection to the Input Handler Application (please refer to OGL:LMT manual), the window shown in Fig. 1.1 is displayed. Fig. 1.1 First Panel of the Input Handler The LMT containment tree is subdivided in four logical areas: BSS-EQUIPMENT, BSS-FUNCTIONAL, SOFTWARE-MANAGEMENT, LMT-INTERNAL. Each area contains an object tree. The user can display the allowed commands of an object by double clicking on the object itself or using the Command List menu item which is activated by left mouse button clicking (see Fig. 1.3). Interworking icons A30808-X3247-L230-3-7619 35 Commands Base Station Controller CML:BSC The IW(Interworking) icons, shown in Fig. 1.1, allow the user to access to BTSEs and TRAU containment sub-trees (see paragraph 1.2.2). Fig. 1.2 Multiversion containment sub-trees For the command trees of Phase 1, Phase 2 see paragraph 1.2.3. i The BTSE, BTSEP, BTSEPICO, BTSEEMand BTSEXS icons allow the user to access to two different containment sub-trees, one belonging to BR6.x release and the other belonging to BR7.0 release (this is due to the fact that the SW of the BR7.0 BSC is backward compatible with BTS BR6.x SW Versions). The two sub-trees are identical, except for the new objects (e.g. SDULNA, SDUSEC, SDUSUBSEC, SDUTXSW) which have been introduced in BR7.0 release (see Fig. 1.2). The BTSECicon allowthe user to access the containment tree related to the BTS equip- ment supporting TD-SCDMA; in this case only the BR7.0 interworkng tree can be opened, because the BTSEC is not supported in BR6.x release. 36 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Fig. 1.3 Second Panel of the Input Handler The Input Handler Main Panel (see Fig. 1.3) can be subdivided in two areas: The left panel contains the object containment tree and can be navigated by the user; each tree leaf can be a node, in which case it can be opened (expanded) or closed. By selecting a leaf, the upper right panel is lled with the command available for the selected object. The right panel contains the command strings, composed by the user using the command panel and sent to the command interpreter (MTCI), together with the possible command interpreter diagnostics. The menu bar contains the menu and, below it, a toolbar. The toolbar contains: ve buttons: the rst three buttons (BSC, BTSE and TRAU) allow the NE selection, while the other two buttons start and stop the recording of command strings. a combobox: which contains the command history, enabling the user to recall a previously issued command into a command panel without needing to reenter the previous parameters. a window: which shows the status of recording operation. In the lower part of the window a status bar shows information about the NE (Network Element) selected, the NE phase, the LMT phase and the user profile. The Input Handler is mainly used to create commands to be sent to the NE. Starting from the containment tree, the user has to perform the following operations: select the object; select a command from the list; ll in the values in the command panel and submit the command. check the correctness of the command. If, during the translation phase, an error is found in the command string, the command is not sent to the NE but an error string A30808-X3247-L230-3-7619 37 Commands Base Station Controller CML:BSC is reported to the user showing the diagnostic message and requesting the user to acknowledge it. Fig. 1.4 shows the Tree-lined Command Viewer panel for a CREATE command. The parameters shown in the command panel are subdivided in groups and they can be listed according to MML position, in alphabetical order or sorted by group position. For more details please refer to OGL:LMT manual. Fig. 1.4 Tree-lined Command Viewer 1.2 LMT BSC Commands 1.2.1 BSC Containment Tree In the next Fig. 1.5, the BSC containment tree is drawn as it is shown to the user in the LMT layout. 38 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Fig. 1.5 BSC containment tree MANAGED-ELEMENT BSS-FUNCTIONAL DISK DK40 EPWR IXLT LICD LICDS MEMT MPCC NTW PPCC PPCU PPLD PWRD TDPC ENVA BSCE REMINV BSCETEST LMT-INTERNAL BSS-EQUIPMENT SOFTWARE-MANAGEMENT BSCESUDB BSCESUSW BSCOSUDB BSCOSUSW FILEHANDLER NEYESUSW RSUDB RSUSWLH SYSINIT RSUEXE RSUPCH BTSE BTSEP BTSEPICO BTSEEM BTSEXS MEL PPXU PPXL TRAUE CPEX FAN BTSEC PPXT PPXP BSC BTS BTSM PWRC LPDLM TRX SCA ADJC FHSY HAND PTPPKF BTSMOSUSW RFLOOP ADJC3G SWIBEAM BTSTD BTSMTD PWRCTD LPDLMTD TRXTD ADJCTD HANDTD PTPPKFTD BTSMTDOSUSW LPDLR CHAN LPDLRTD AIRTSTD PCU TGTFDD SCANBTS SCANBTSIHO SCANBTSM SCANBTSOHOI SCANBTSOHON SCANGPRS SCANBTSE SCANSS7L SCANTRX TRAU SCANBSC SCANCHAN SCANCO SCANCTRX LPDLS TRAUOSUSW SYNE SYNCO SYNC TSLA PCMA PCMB PCMG TSLB PCMS SUBTSLB TRACE CTRSCHED SS7S SS7L OMAL NSVC NUC FRL CBCL X25A X25D OPC CTRCO TDCU PCUTD TGTTDD TGTBTS TGTPTPPKF SCANBTSOHOS SCANFBTSM IPLI SCANAIRTSTD SCANBTSABISTD SCANBTSTD SCANBTSTDIHDO SCANBTSTDOHDOI SCANBTSTDOHDON SCANGPRSTD SCANTRXABISTD SCANTRXTD SCANBTSMTD TGTBTSTD A30808-X3247-L230-3-7619 39 Commands Base Station Controller CML:BSC 1.2.2 BTS Equipment and TRAU Containment Sub-Trees Using the IW (Interworking) icons the operator can have access to the BTS equipment and TRAU containment sub-trees to perform interworking commands. The following containment sub-trees are provided: BTSE It is related to the following BTSE types: BS-20, BS-21E, BS-22, BS-60 and BS-61E. Fig. 1.6 BTSE containment sub-tree The IW icon BSC-MASTER allows the operator to return the BSC containment tree. For the list of the commands related to each BTSE object refer to paragraph BTSE in Chapter 3 (BTS and TRAU Objects and Commands) of this manual. 40 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BTSEP It is related to the following BTSE types: BS-240, BS-240SR, BS-241, BS-241SR, BS-240XL, BS-240XLSR, BS-40 and BS-41. Fig. 1.7 BTSEP containment sub-tree The IW icon BSC-MASTER allows the operator to return the BSC containment tree. For the list of the commands related to each BTSEP object refer to paragraph BTSEP in Chapter 3 (BTS and TRAU Objects and Commands) of this manual. A30808-X3247-L230-3-7619 41 Commands Base Station Controller CML:BSC BTSEPICO It is related to the BS-242 BTSE type. Fig. 1.8 BTSEPICO containment sub-tree The IW icon BSC-MASTER allows the operator to return the BSC containment tree. For the list of the commands related to each BTSEPICO object refer to paragraph BTSEPICO in Chapter 3 (BTS and TRAU Objects and Commands) of this manual. 42 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BTSEEM It is related to the BS-82 BTSE type. Fig. 1.9 BTSEEM containment sub-tree The IW icon BSC-MASTER allows the operator to return the BSC containment tree. For the list of the commands related to each BTSEEM object refer to paragraph BTSEEM in Chapter 3 (BTS and TRAU Objects and Commands) of this manual. A30808-X3247-L230-3-7619 43 Commands Base Station Controller CML:BSC BTSEXS It is related to the BS-240XS BTSE type. Fig. 1.10 BTSEXS containment sub-tree The IW icon BSC-MASTER allows the operator to return the BSC containment tree. For the list of the commands related to each BTSEXS object refer to paragraph BTSEXS in Chapter 3 (BTS and TRAU Objects and Commands) of this manual. 44 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BTSEC It is related to the BTSE type supporting TD-SCDMA functionality. Fig. 1.11 BTSEC containment sub-tree The IW icon BSC-MASTER allows the operator to return the BSC containment tree. For the list of the commands related to each BTSEC object refer to paragraph BTSEC in Chapter 3 (BTS and TRAU Objects and Commands) of this manual. A30808-X3247-L230-3-7619 45 Commands Base Station Controller CML:BSC TRAUE It is related to TRAU equipment. Fig. 1.12 TRAUE containment sub-tree The IW icon BSC-MASTER allows the operator to return the BSC containment tree. For the list of the commands related to each TRAUE object refer to paragraph TRAUE in Chapter 3 (BTS and TRAU Objects and Commands) of this manual. 46 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 1.2.3 Alphabetical List of Commands ADJC ADJC3G ADJCTD AIRTSTD Managed Element Phase 1 Phase 2 CREATE ADJC DELETE ADJC GET ADJC GET ADJC BASICS SET ADJC CREATE ADJC3G DELETE ADJC3G GET ADJC3G GET ADJC3G BASICS SET ADJC3G CREATE ADJCTD DELETE ADJCTD GET ADJCTD GET ADJCTD BASICS SET ADJCTD CREATE AIRTSTD DELETE AIRTSTD GET AIRTSTD GET AIRTSTD BASICS GET AIRTSTD STAT GETRELATIONSHIP AIRTSTD GETSUBO AIRTSTD LOCK AIRTSTD SET AIRTSTD SHUTDOWN AIRTSTD UNLOCK AIRTSTD A30808-X3247-L230-3-7619 47 Commands Base Station Controller CML:BSC BSC BSCE BSCESUDB BSCESUSW BSCETEST Managed Element Phase 1 Phase 2 GET BSC GET BSC ALARMSEV GET BSC BASICS GET BSC CONTROL GET BSC STAT GET BSC TIMER GETLOCKED BSC MEMDUMP BSC SET BSC GET BSCE GET BSCE ALARMSEV GET BSCE REMINV GETACTIVEALARMS BSCE PERFTEST BSCE SET BSCE STOPTEST BSCE GET BSCESUDB GET BSCESUDB BASICS GET BSCESUDB STAT GETINFO BSCESUDB GET BSCESUSW GET BSCESUSW BASICS GET BSCESUSW STAT GETINFO BSCESUSW GET BSCETEST 48 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BSCOSUDB BSCOSUSW BTS Managed Element Phase 1 Phase 2 GET BSCOSUDB GET BSCOSUDB BASICS GETINFO BSCOSUDB SAVEDB BSCOSUDB SET BSCOSUDB SETRUNNEW BSCOSUDB GET BSCOSUSW GET BSCOSUSW BASICS GETINFO BSCOSUSW SET BSCOSUSW SETBACKNEW BSCOSUSW SETRUNBACK BSCOSUSW SETRUNNEW BSCOSUSW CREATE BTS DELETE BTS GET BTS GET BTS BASICS GET BTS CCCH GET BTS INTERF GET BTS OPTIONS GET BTS STAT GET BTS TIMER GETINFO BTS GETRELATIONSHIP BTS GETSUBO BTS LOCK BTS MONITOR BTS SET BTS SHUTDOWN BTS UNLOCK BTS A30808-X3247-L230-3-7619 49 Commands Base Station Controller CML:BSC BTSM BTSMOSUSW BTSMTD Managed Element Phase 1 Phase 2 CREATE BTSM DELETE BTSM GET BTSM GET BTSM BASICS GET BTSM STAT GETINFO BTSM GETRELATIONSHIP BTSM GETSUBO BTSM LOCK BTSM SET BTSM SHUTDOWN BTSM UNLOCK BTSM GET BTSMOSUSW GET BTSMOSUSW BASICS GETINFO BTSMOSUSW SETRUNBACK BTSMOSUSW CREATE BTSMTD DELETE BTSMTD GET BTSMTD GET BTSMTD BASICS GET BTSMTD STAT GETINFO BTSMTD GETRELATIONSHIP BTSMTD GETSUBO BTSMTD LOCK BTSMTD SET BTSMTD SHUTDOWN BTSMTD UNLOCK BTSMTD 50 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BTSMTDOSUSW BTSTD CBCL Managed Element Phase 1 Phase 2 GET BTSMTDOSUSW GET BTSMTDOSUSW BASICS GETINFO BTSMTDOSUSW SETRUNBACK BTSMTDOSUSW CREATE BTSTD DELETE BTSTD GET BTSTD GET BTSTD BASICS GET BTSTD CCCH GET BTSTD OPTIONS GET BTSTD STAT GET BTSTD TIMER GETINFO BTSTD GETRELATIONSHIP BTSTD GETSUBO BTSTD LOCK BTSTD SET BTSTD SHUTDOWN BTSTD UNLOCK BTSTD CREATE CBCL DELETE CBCL GET CBCL GET CBCL BASICS GET CBCL STAT GET CBCLX25INFO GETRELATIONSHIP CBCL LOCK CBCL UNLOCK CBCL A30808-X3247-L230-3-7619 51 Commands Base Station Controller CML:BSC CHAN CPEX CTRCO CTRSCHED Managed Element Phase 1 Phase 2 CREATE CHAN DELETE CHAN GET CHAN GET CHAN BASICS GET CHAN STAT GETRELATIONSHIP CHAN GETSUBO CHAN LOCK CHAN SET CHAN SHUTDOWN CHAN UNLOCK CHAN GET CPEX STAT GETRELATIONSHIP CPEX GETSUBO CPEX GETTEST CPEX LOCK CPEX PERFTEST CPEX STOPTEST CPEX UNLOCK CPEX GET CTRCO STAT GETINFO CTRCO LOCK CTRCO UNLOCK CTRCO UPLALLCELLTR CTRCO UPLCELLTR CTRCO CREATE CTRSCHED DELETE CTRSCHED GET CTRSCHED GET CTRSCHED BASICS GET CTRSCHED STAT LOCK CTRSCHED SET CTRSCHED UNLOCK CTRSCHED 52 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DISK DK40 ENVA EPWR Managed Element Phase 1 Phase 2 FORMAT DISK GET DISK STAT GETRELATIONSHIP DISK GETSUBO DISK GETTEST DISK LOCK DISK PERFTEST DISK STOPTEST DISK UNLOCK DISK GET DK40 STAT GETRELATIONSHIP DK40 GETSUBO DK40 GETTEST DK40 LOCK DK40 PERFTEST DK40 STOPTEST DK40 UNLOCK DK40 CREATE ENVA DELETE ENVA GET ENVA GET ENVA BASICS GET ENVA STAT LOCK ENVA SET ENVA UNLOCK ENVA CREATE EPWR DELETE EPWR GET EPWR GET EPWR STAT GETSUBO EPWR GETTEST EPWR LOCK EPWR PERFTEST EPWR STOPTEST EPWR UNLOCK EPWR A30808-X3247-L230-3-7619 53 Commands Base Station Controller CML:BSC FAN FHSY FILEHANDLER FRL HAND Managed Element Phase 1 Phase 2 GET FAN STAT GETRELATIONSHIP FAN GETSUBO FAN CREATE FHSY DELETE FHSY GET FHSY GET FHSY BASICS SET FHSY COPY FILEHANDLER CREATEDIR FILEHANDLER DELETE FILEHANDLER GENFILE DIR FILEHANDLER FILECOM FILEHANDLER FILEDECOM FILEHANDLER MOVE FILEHANDLER REMOVEDIR FILEHANDLER UPLPRLOG FILEHANDLER CREATE FRL DELETE FRL GET FRL GET FRL BASICS GET FRL STAT GETINFO FRL GETRELATIONSHIP FRL GETSUBO FRL LOCK FRL SET FRL UNLOCK FRL GET HAND GET HAND BASICS GET HAND DATA SET HAND 54 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller HANDTD IPLI IXLT LICD Managed Element Phase 1 Phase 2 GET HANDTD GET HANDTD BASICS SET HANDTD CREATE IPLI DELETE IPLI GET IPLI GET IPLI BASICS GET IPLI STAT GETINFO IPLI GETRELATIONSHIP IPLI PING IPLI SET IPLI GET IXLT STAT GETINFO IXLT GETRELATIONSHIP IXLT GETTEST IXLT LOCK IXLT PERFTEST IXLT STOPTEST IXLT UNLOCK IXLT CREATE LICD DELETE LICD GET LICD GET LICD BASICS GET LICD STAT GETINFO LICD GETRELATIONSHIP LICD GETSUBO LICD GETTEST LICD LOCK LICD PERFTEST LICD SET LICD STOPTEST LICD UNLOCK LICD A30808-X3247-L230-3-7619 55 Commands Base Station Controller CML:BSC LICDS LMT-INTERNAL LPDLM Managed Element Phase 1 Phase 2 CREATE LICDS DELETE LICDS GET LICDS GET LICDS STAT GETRELATIONSHIP LICDS GETSUBO LICDS GETTEST LICDS LOCK LICDS PERFTEST LICDS STOPTEST LICDS UNLOCK LICDS ECHO ECHO EXEC EXEC SET SET CREATE LPDLM DELETE LPDLM GET LPDLM GET LPDLM BASICS GET LPDLM STAT GETINFO LPDLM GETRELATIONSHIP LPDLM GETSUBO LPDLM 56 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller LPDLMTD LPDLR LPDLRTD LPDLS MEL Managed Element Phase 1 Phase 2 CREATE LPDLMTD DELETE LPDLMTD GET LPDLMTD GET LPDLMTD BASICS GET LPDLMTD STAT GETINFO LPDLMTD GETRELATIONSHIP LPDLMTD GETSUBO LPDLMTD GET LPDLR STAT GETINFO LPDLR GETRELATIONSHIP LPDLR GETSUBO LPDLR GET LPDLRTD STAT GETINFO LPDLRTD GETRELATIONSHIP LPDLRTD GETSUBO LPDLRTD CREATE LPDLS DELETE LPDLS GET LPDLS GET LPDLS BASICS GET LPDLS STAT GETINFO LPDLS GETRELATIONSHIP LPDLS GETSUBO LPDLS SET LPDLS GET MEL GET MEL BASICS SET MEL A30808-X3247-L230-3-7619 57 Commands Base Station Controller CML:BSC MEMT MPCC NEYESUSW Managed Element Phase 1 Phase 2 GET MEMT STAT GETRELATIONSHIP MEMT GETSUBO MEMT GETTEST MEMT LOCK MEMT PERFTEST MEMT STOPTEST MEMT SWITCH MEMT UNLOCK MEMT GET MPCC STAT GETINFO MPCC GETRELATIONSHIP MPCC GETSUBO MPCC GETTEST MPCC LOCK MPCC PERFTEST MPCC STOPTEST MPCC SWITCH MPCC UNLOCK MPCC GET NEYESUSW GET NEYESUSW BASICS GET NEYESUSW STAT GETINFO NEYESUSW NEDOWNLOAD NEYESUSW NEDOWNLOADABO NEYESUSW 58 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller NSVC NTW NUC Managed Element Phase 1 Phase 2 CREATE NSVC DELETE NSVC GET NSVC GET NSVC BASICS GET NSVC STAT GETINFO NSVC GETRELATIONSHIP NSVC GETSUBO NSVC LOCK NSVC UNLOCK NSVC FORCSYNC NTW GET NTW STAT GETRELATIONSHIP NTW GETSUBO NTW GETSYNC NTW GETTEST NTW LOCK NTW PERFTEST NTW STOPTEST NTW SWITCH NTW UNLOCK NTW UPDATETUNE NTW CREATE NUC DELETE NUC GET NUC GET NUC BASICS GET NUC STAT GETRELATIONSHIP NUC A30808-X3247-L230-3-7619 59 Commands Base Station Controller CML:BSC OMAL OPC PCMA Managed Element Phase 1 Phase 2 CREATE OMAL DELETE OMAL GET OMAL GET OMAL BASICS GET OMAL STAT GET OMAL X25INFO GETRELATIONSHIP OMAL GETSUBO OMAL SET OMAL CREATE OPC DELETE OPC GET OPC GET OPC BASICS GET OPC MTL2 GET OPC MTL3 GETINFO OPC SET OPC CREATE PCMA DELETE PCMA GET PCMA GET PCMA BASICS GET PCMA PCM24 GET PCMA PCM30 GET PCMA STAT GETINFO PCMA GETRELATIONSHIP PCMA GETSUBO PCMA LOCK PCMA SHUTDOWN PCMA UNLOCK PCMA 60 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PCMB PCMG Managed Element Phase 1 Phase 2 CREATE PCMB DELETE PCMB GET PCMB GET PCMB BASICS GET PCMB PCM24 GET PCMB PCM30 GET PCMB STAT GETINFO PCMB GETREDSTAT PCMB GETRELATIONSHIP PCMB GETSUBO PCMB LOCK PCMB SET PCMB UNLOCK PCMB CREATE PCMG DELETE PCMG GET PCMG GET PCMG BASICS GET PCMG PCM24 GET PCMG PCM30 GET PCMG STAT GETINFO PCMG GETRELATIONSHIP PCMG GETSUBO PCMG LOCK PCMG SET PCMG UNLOCK PCMG A30808-X3247-L230-3-7619 61 Commands Base Station Controller CML:BSC PCMS PCU PCUTD Managed Element Phase 1 Phase 2 CREATE PCMS DELETE PCMS GET PCMS GET PCMS BASICS GET PCMS PCM24 GET PCMS PCM30 GET PCMS STAT GETINFO PCMS GETREDSTAT PCMS GETRELATIONSHIP PCMS GETSUBO PCMS LOCK PCMS SET PCMS UNLOCK PCMS CREATE PCU DELETE PCU GET PCU GET PCU BASICS GET PCU STAT GETINFO PCU GETRELATIONSHIP PCU GETSUBO PCU LOCK PCU SET PCU UNLOCK PCU CREATE PCUTD DELETE PCUTD GET PCUTD GET PCUTD BASICS GET PCUTD STAT GETINFO PCUTD GETRELATIONSHIP PCUTD GETSUBO PCUTD LOCK PCUTD SET PCUTD UNLOCK PCUTD 62 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PPCC PPCU PPLD Managed Element Phase 1 Phase 2 GET PPCC STAT GETINFO PPCC GETRELATIONSHIP PPCC GETSUBO PPCC GETTEST PPCC LOCK PPCC PERFTEST PPCC STOPTEST PPCC UNLOCK PPCC GET PPCU STAT GETINFO PPCU GETRELATIONSHIP PPCU GETSUBO PPCU GETTEST PPCU LOCK PPCU PERFTEST PPCU STOPTEST PPCU SWITCH PPCU UNLOCK PPCU CREATE PPLD DELETE PPLD GET PPLD GET PPLD STAT GETINFO PPLD GETRELATIONSHIP PPLD GETSUBO PPLD GETTEST PPLD LOCK PPLD PERFTEST PPLD STOPTEST PPLD UNLOCK PPLD A30808-X3247-L230-3-7619 63 Commands Base Station Controller CML:BSC PPXL PPXP PPXT Managed Element Phase 1 Phase 2 GET PPXL STAT GETINFO PPXL GETRELATIONSHIP PPXL GETSUBO PPXL GETTEST PPXL LOCK PPXL PERFTEST PPXL STOPTEST PPXL UNLOCK PPXL GET PPXP STAT GETINFO PPXP GETRELATIONSHIP PPXP GETSUBO PPXP GETTEST PPXP LOCK PPXP PERFTEST PPXP STOPTEST PPXP UNLOCK PPXP CREATE PPXT DELETE PPXT GET PPXT GET PPXT STAT GETINFO PPXT GETRELATIONSHIP PPXT GETSUBO PPXT GETTEST PPXT LOCK PPXT PERFTEST PPXT STOPTEST PPXT UNLOCK PPXT 64 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PPXU PTPPKF PTPPKFTD PWRC Managed Element Phase 1 Phase 2 GET PPXU STAT GETINFO PPXU GETRELATIONSHIP PPXU GETSUBO PPXU GETTEST PPXU LOCK PPXU PERFTEST PPXU STOPTEST PPXU UNLOCK PPXU CREATE PTPPKF DELETE PTPPKF GET PTPPKF GET PTPPKF BASICS GET PTPPKF STAT GETINFO PTPPKF GETRELATIONSHIP PTPPKF GETSUBO PTPPKF LOCK PTPPKF SET PTPPKF UNLOCK PTPPKF CREATE PTPPKFTD DELETE PTPPKFTD GET PTPPKFTD GET PTPPKFTD BASICS GET PTPPKFTD STAT GETINFO PTPPKFTD GETRELATIONSHIP PTPPKFTD GETSUBO PTPPKFTD LOCK PTPPKFTD SET PTPPKFTD UNLOCK PTPPKFTD GET PWRC GET PWRC BASICS SET PWRC A30808-X3247-L230-3-7619 65 Commands Base Station Controller CML:BSC PWRCTD PWRD REMINV RFLOOP Managed Element Phase 1 Phase 2 GET PWRCTD GET PWRCTD BASICS SET PWRCTD GET PWRD STAT GETRELATIONSHIP PWRD GETSUBO PWRD GETTEST PWRD LOCK PWRD PERFTEST PWRD STOPTEST PWRD UNLOCK PWRD ALIGN REMINV DNLIDFD REMINV GET REMINV STAT LOCK REMINV UNLOCK REMINV UPLCIDF REMINV UPLLIDF REMINV CREATE RFLOOP DELETE RFLOOP GET RFLOOP GET RFLOOP BASICS GET RFLOOP STAT LOCK RFLOOP SET RFLOOP UNLOCK RFLOOP UPLOADREQ RFLOOP 66 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller RSUDB RSUEXE RSUPCH RSUSWLH Managed Element Phase 1 Phase 2 CREATE RSUDB DELETE RSUDB GET RSUDB GET RSUDB BASICS GET RSUDB STAT SET RSUDB UPLDFILE RSUDB CREATE RSUEXE DELETE RSUEXE GET RSUEXE GET RSUEXE BASICS GET RSUEXE STAT CREATE RSUPCH DELETE RSUPCH GET RSUPCH GET RSUPCH BASICS GET RSUPCH STAT LOADPATCH RSUPCH SET RSUPCH UNLOADPCH RSUPCH CREATE RSUSWLH DELETE RSUSWLH GET RSUSWLH GET RSUSWLH BASICS GET RSUSWLH STAT SET RSUSWLH A30808-X3247-L230-3-7619 67 Commands Base Station Controller CML:BSC SCA SCANAIRTSTD SCANBSC Managed Element Phase 1 Phase 2 CREATE SCA DELETE SCA GET SCA GET SCA BASICS GET SCA EICM GET SCA NMDL GET SCA STAT LOCK SCA SET SCA UNLOCK SCA UPLOADREQ SCA ADD SCANAIRTSTD CREATE SCANAIRTSTD DELETE SCANAIRTSTD GET SCANAIRTSTD GET SCANAIRTSTD BASICS GET SCANAIRTSTD STAT LOCK SCANAIRTSTD REMOVE SCANAIRTSTD SET SCANAIRTSTD UNLOCK SCANAIRTSTD ACTIVATE SCANBSC ADD SCANBSC CREATE SCANBSC DELETE SCANBSC GET SCANBSC GET SCANBSC BASICS GET SCANBSC STAT LOCK SCANBSC REMOVE SCANBSC SET SCANBSC UNLOCK SCANBSC 68 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SCANBTS SCANBTSABISTD SCANBTSE Managed Element Phase 1 Phase 2 ADD SCANBTS CREATE SCANBTS DELETE SCANBTS GET SCANBTS GET SCANBTS BASICS GET SCANBTS STAT LOCK SCANBTS REMOVE SCANBTS SET SCANBTS UNLOCK SCANBTS ADD SCANBTSABISTD CREATE SCANBTSABISTD DELETE SCANBTSABISTD GET SCANBTSABISTD GET SCANBTSABISTD BASICS GET SCANBTSABISTD STAT LOCK SCANBTSABISTD REMOVE SCANBTSABISTD SET SCANBTSABISTD UNLOCK SCANBTSABISTD ADD SCANBTSE CREATE SCANBTSE DELETE SCANBTSE GET SCANBTSE GET SCANBTSE BASICS GET SCANBTSE STAT LOCK SCANBTSE REMOVE SCANBTSE SET SCANBTSE UNLOCK SCANBTSE A30808-X3247-L230-3-7619 69 Commands Base Station Controller CML:BSC SCANBTSIHO SCANBTSM SCANBTSMTD Managed Element Phase 1 Phase 2 ADD SCANBTSIHO CREATE SCANBTSIHO DELETE SCANBTSIHO GET SCANBTSIHO GET SCANBTSIHO BASICS GET SCANBTSIHO STAT LOCK SCANBTSIHO REMOVE SCANBTSIHO SET SCANBTSIHO UNLOCK SCANBTSIHO ADD SCANBTSM CREATE SCANBTSM DELETE SCANBTSM GET SCANBTSM GET SCANBTSM BASICS GET SCANBTSM STAT LOCK SCANBTSM REMOVE SCANBTSM SET SCANBTSM UNLOCK SCANBTSM ADD SCANBTSMTD CREATE SCANBTSMTD DELETE SCANBTSMTD GETSCANBTSMTD GET SCANBTSMTD BASICS GET SCANBTSMTD STAT LOCK SCANBTSMTD REMOVE SCANBTSMTD SET SCANBTSMTD UNLOCK SCANBTSMTD 70 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SCANBTSOHOI SCANBTSOHON SCANBTSOHOS Managed Element Phase 1 Phase 2 ADD SCANBTSOHOI CREATE SCANBTSOHOI DELETE SCANBTSOHOI GET SCANBTSOHOI GET SCANBTSOHOI BASICS GET SCANBTSOHOI STAT LOCK SCANBTSOHOI REMOVE SCANBTSOHOI SET SCANBTSOHOI UNLOCK SCANBTSOHOI ADD SCANBTSOHON CREATE SCANBTSOHON DELETE SCANBTSOHON GET SCANBTSOHON GET SCANBTSOHON BASICS GET SCANBTSOHON STAT LOCK SCANBTSOHON REMOVE SCANBTSOHON SET SCANBTSOHON UNLOCK SCANBTSOHON ADD SCANBTSOHOS CREATE SCANBTSOHOS DELETE SCANBTSOHOS GET SCANBTSOHOS GET SCANBTSOHOS BASICS GET SCANBTSOHOS STAT LOCK SCANBTSOHOS REMOVE SCANBTSOHOS SET SCANBTSOHOS UNLOCK SCANBTSOHOS A30808-X3247-L230-3-7619 71 Commands Base Station Controller CML:BSC SCANBTSTD SCANBTSTDIHDO SCANBTSTDOHDOI Managed Element Phase 1 Phase 2 ADD SCANBTSTD CREATE SCANBTSTD DELETE SCANBTSTD GET SCANBTSTD GET SCANBTSTD BASICS GET SCANBTSTD STAT LOCK SCANBTSTD REMOVE SCANBTSTD SET SCANBTSTD UNLOCK SCANBTSTD ADD SCANBTSTDIHDO CREATE SCANBTSTDIHDO DELETE SCANBTSTDIHDO GET SCANBTSTDIHDO GET SCANBTSTDIHDO BASICS GET SCANBTSTDIHDO STAT LOCK SCANBTSTDIHDO REMOVE SCANBTSTDIHDO SET SCANBTSTDIHDO UNLOCK SCANBTSTDIHDO ADD SCANBTSTDOHDOI CREATE SCANBTSTDOHDOI DELETE SCANBTSTDOHDOI GET SCANBTSTDOHDOI GET SCANBTSTDOHDOI BASICS GET SCANBTSTDOHDOI STAT LOCK SCANBTSTDOHDOI REMOVE SCANBTSTDOHDOI SET SCANBTSTDOHDOI UNLOCK SCANBTSTDOHDOI 72 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SCANBTSTDOHDON SCANCHAN SCANCO SCANCTRX Managed Element Phase 1 Phase 2 ADD SCANBTSTDOHDON CREATE SCANBTSTDOHDON DELETE SCANBTSTDOHDON GET SCANBTSTDOHON GET SCANBTSTDOHDON BASICS GET SCANBTSTDOHDON STAT LOCK SCANBTSTDOHDON REMOVE SCANBTSTDOHDON SET SCANBTSTDOHDON UNLOCK SCANBTSTDOHDON ADD SCANCHAN CREATE SCANCHAN DELETE SCANCHAN GET SCANCHAN GET SCANCHAN BASICS GET SCANCHAN STAT LOCK SCANCHAN REMOVE SCANCHAN SET SCANCHAN UNLOCK SCANCHAN GETINFO SCANCO UPLMEAS SCANCO ADD SCANCTRX CREATE SCANCTRX DELETE SCANCTRX GET SCANCTRX GET SCANCTRX BASICS GET SCANCTRX STAT LOCK SCANCTRX REMOVE SCANCTRX SET SCANCTRX UNLOCK SCANCTRX A30808-X3247-L230-3-7619 73 Commands Base Station Controller CML:BSC SCANFBTSM SCANGPRS SCANGPRSTD Managed Element Phase 1 Phase 2 ADD SCANFBTSM CREATE SCANFBTSM DELETE SCANFBTSM GET SCANFBTSM GET SCANFBTSM BASICS LOCK SCANFBTSM REMOVE SCANFBTSM SET SCANFBTSM UNLOCK SCANFBTSM ADD SCANGPRS CREATE SCANGPRS DELETE SCANGPRS GET SCANGPRS GET SCANGPRS BASICS GET SCANGPRS STAT LOCK SCANGPRS REMOVE SCANGPRS SET SCANGPRS UNLOCK SCANGPRS ADD SCANGPRSTD CREATE SCANGPRSTD DELETE SCANGPRSTD GET SCANGPRSTD GET SCANGPRSTDTD BASICS GET SCANGPRSTD STAT LOCK SCANGPRSTD REMOVE SCANGPRSTD SET SCANGPRSTD UNLOCK SCANGPRSTD 74 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SCANSS7L SCANTRX SCANTRXABISTD Managed Element Phase 1 Phase 2 ACTIVATE SCANSS7L ADD SCANSS7L CREATE SCANSS7L DELETE SCANSS7L GET SCANSS7L GET SCANSS7L BASICS GET SCANSS7L STAT LOCK SCANSS7L REMOVE SCANSS7L SET SCANSS7L UNLOCK SCANSS7L ADD SCANTRX CREATE SCANTRX DELETE SCANTRX GET SCANTRX GET SCANTRX BASICS GET SCANTRX STAT LOCK SCANTRX REMOVE SCANTRX SET SCANTRX UNLOCK SCANTRX ADD SCANTRXABISTD CREATE SCANTRXABISTD DELETE SCANTRXABISTD GET SCANTRXABISTD GET SCANTRXABISTD BASICS GET SCANTRXABISTD STAT LOCK SCANTRXABISTD REMOVE SCANTRXABISTD SET SCANTRXABISTD UNLOCK SCANTRXABISTD A30808-X3247-L230-3-7619 75 Commands Base Station Controller CML:BSC SCANTRXTD SOFTWARE-MANAGEMENT SS7L SS7S Managed Element Phase 1 Phase 2 ADD SCANTRXTD CREATE SCANTRXTD DELETE SCANTRXTD GET SCANTRXTD GET SCANTRXTD BASICS GET SCANTRXTD STAT LOCK SCANTRXTD REMOVE SCANTRXTD SET SCANTRXTD UNLOCK SCANTRXTD LOADMPCC DNLFILE UPLBTSLOG UPLBTSTDLOG UPLFILE UPLTRAULOG CREATE SS7L DELETE SS7L GET SS7L GET SS7L BASICS GET SS7L STAT GETRELATIONSHIP SS7L GETSUBO SS7L INHIBIT SS7L LOCK SS7L TESTLINK SS7L UNINHIBIT SS7L UNLOCK SS7L GET SS7S STAT GETSUBO SS7S 76 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SUBTSLB SWIBEAM SYNC SYNCO SYNE Managed Element Phase 1 Phase 2 CREATE SUBTSLB DELETE SUBTSLB GET SUBTSLB GET SUBTSLB BASICS GET SUBTSLB STAT LOCK SUBTSLB SHUTDOWN SUBTSLB UNLOCK SUBTSLB CREATE SWIBEAM DELETE SWIBEAM GET SWIBEAM GET SWIBEAM BASICS GET SWIBEAM CSSERV SET SWIBEAM CREATE SYNC DELETE SYNC GET SYNC GET SYNC BASICS GET SYNC STAT GETRELATIONSHIP SYNC GETSUBO SYNC LOCK SYNC UNLOCK SYNC GETINFO SYNCO CREATE SYNE DELETE SYNE FREQMEAS SYNE GET SYNE GET SYNE STAT LOCK SYNE UNLOCK SYNE A30808-X3247-L230-3-7619 77 Commands Base Station Controller CML:BSC SYSINIT TDCU TDPC TGTBTS TGTBTSTD Managed Element Phase 1 Phase 2 SYSINIT SYSINIT CREATE TDCU DELETE TDCU GET TDCU GET TDCU STAT GETINFO TDCU GETRELATIONSHIP TDCU GETSUBO TDCU LOCK TDCU SHUTDOWN TDCU UNLOCK TDCU GET TDPC STAT GETINFO TDPC GETRELATIONSHIP TDPC GETSUBO TDPC GETTEST TDPC LOCK TDPC PERFTEST TDPC STOPTEST TDPC SWITCH TDPC UNLOCK TDPC CREATE TGTBTS DELETE TGTBTS GET TGTBTS GET TGTBTS BASICS SET TGTBTS CREATE TGTBTSTD DELETE TGTBTSTD GET TGTBTSTD GET TGTBTSTD BASICS SET TGTBTSTD 78 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TGTFDD TGTPTPPKF TGTTDD TRACE Managed Element Phase 1 Phase 2 CREATE TGTFDD DELETE TGTFDD GET TGTFDD GET TGTFDD BASICS SET TGTFDD CREATE TGTPTPPKF DELETE TGTPTPPKF GET TGTPTPPKF GET TGTPTPPKF BASICS SET TGTPTPPKF CREATE TGTTDD DELETE TGTTDD GET TGTTDD GET TGTTDD BASICS SET TGTTDD CREATE TRACE DELETE TRACE GET TRACE GET TRACE BASICS GET TRACE STAT GETINFO TRACE LOCK TRACE SHUTDOWN TRACE UNLOCK TRACE UPLALLIMSITR TRACE UPLIMSITR TRACE A30808-X3247-L230-3-7619 79 Commands Base Station Controller CML:BSC TRAU TRAUOSUSW TRX Managed Element Phase 1 Phase 2 CREATE TRAU DELETE TRAU GET TRAU GET TRAU BASICS GET TRAU STAT GET TRAU TIMER GETINFO TRAU GETRELATIONSHIP TRAU GETSUBO TRAU LOCK TRAU SET TRAU SHUTDOWN TRAU UNLOCK TRAU GET TRAUOSUSW GET TRAUOSUSW BASICS GETINFO TRAUOSUSW SETRUNBACK TRAUOSUSW CREATE TRX DELETE TRX GET TRX GET TRX BASICS GET TRX STAT GETINFO TRX GETRELATIONSHIP TRX GETSUBO TRX LOCK TRX SET TRX SHUTDOWN TRX UNLOCK TRX 80 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TRXTD TSLA TSLB Managed Element Phase 1 Phase 2 CREATE TRXTD DELETE TRXTD GET TRXTD GET TRXTD BASICS GET TRXTD STAT GETINFO TRXTD GETRELATIONSHIP TRXTD GETSUBO TRXTD LOCK TRXTD SET TRXTD SHUTDOWN TRXTD UNLOCK TRXTD GET TSLA GET TSLA BASICS GET TSLA STAT GETRELATIONSHIP TSLA GETSUBO TSLA LOCK TSLA SET TSLA SHUTDOWN TSLA UNLOCK TSLA GET TSLB A30808-X3247-L230-3-7619 81 Commands Base Station Controller CML:BSC X25A X25D Managed Element Phase 1 Phase 2 CREATE X25A DELETE X25A GET X25A GET X25A BASICS GET X25A STAT GETINFO X25A GETRELATIONSHIP X25A SET X25A CREATE X25D DELETE X25D GET X25D GET X25D BASICS GET X25D STAT GETINFO X25D GETRELATIONSHIP X25D SET X25D 82 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller A30808-X3247-L230-3-7619 83 Commands Base Station Controller CML:BSC 2 Objects and Commands in Alphabetical Order In case of DBA Nack Responses, if no specific Additional Information can be provided to the operator, the "addInfo" field of the response itself is filled using the format: Module = 0x00xx, line = yyyy This information is useful to BSC development to understand quickly why the nack response occurred. ADJC The ADJC (Adjacent Cell) object represents one of the adjacent cells that are to be monitored for handover purposes. CREATE ADJC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS ADJC CREATE ADJC Applicability: Phase 2. Visibility level 2. Command Description: This command sets the specific parameters for the adjacent cells of a given cell. Validity ranges of the object addresses "btsmn", btsn and "adjcn" can be found in Appendix A. System Responses: CREATE ADJC: NAME=BTSM:btsmn/BTS:btsn/ADJC:adjcn,TGTCELL= [,RXLEVMIN=] [,HOM=] [,HOMSOFF=] [,HOMDTIME=] [,HOMDOFF=] [,MICROCELL=] [,FHORLMO=] [,TIMERFHO=] [,PLNC=] [,PPLNC=] [,LEVONC=] [,TINHBAKHO=] [,TINHFAIHO=] [,GSUP=] [,GTEMPOFF=] [,GPENTIME=] [,GRESOFF=] [,GHCSTH=] [,GHCSPC=] [,FULHOC=] [,FULRXLVMOFF=] [,TRFHOM=] [,BHOFOT=] [,LEVHOM=] [,USG=] [,NCGRESOFF=] [,NCGTEM- POFF=] [,NCGPENTIME=] [,NCC1THADJC=] [,TRFHORXLVMOFF=] ; CREATE ACK: Successful CREATE NACK: NACK CAUSES: 84 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. No administrative state is associated with this object. 2. The attribute penalityPriorityNcell (PPLNC) must be set to a value not smaller than the attributepriorityLayerNcell (PLNC). 3. The timer TIMERFHO is running on the adjacent cell serving the Directed Retry signalling procedure: that is the timer is dened in ADJC A-B for Directed Retry from A to B. 4. The attribute TINHFAIHO should be set at a value greater than the timer BSCT7 (see BSC object) and timer THORQST (see HAND object). UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The BTS object instance must be already equipped. The TGTBTS object instance must be already equipped. If GSUP is TRUE the relative PTPPKF and TGTPTPPKF (for external cells) object instances must be already equipped. UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. MAX_ADJC_COMPL_BAND_EXCEEDED The number of adjacent cells having their BCCHFREQ in the comple- mentary band exceeds the allowed maximum number. For more details, see Application Guideline n. 7. LAST_ADJC_RESERVED_FOR_LOTRACH When the intracell handovers are MSC controlled (attribute LOTRACH of HAND object set at FALSE) one of the 32 allowed ADJCs is reserved by BSC for LOTRACH handling. So the operator can configure only 31 ADJC cells. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. UNSUCCESSFUL_INVALID_TARGET_CELL The serving cell and the target cell must be different. An ADJC with the same serving and target cell already exist. UNSUCCESSFUL_INVALID_BCCF The target cell and the serving cell must have different BCCH frequen- cies. TOO_MANY_REFERENCES_TO_TARGET_CELL The maximum number of adjacent cells for the target cell (96) has been reached. SUBORDINATE_EQUIPPED In order to set the GSUP parameter at TRUE value, both the serving and the target cells must have the relative PTPPKF already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the SCA object instance related to the BTS is in LOCKED state UNSUCCESSFUL_BCCF_OUT_OF_RANGE The selected value for the BCCH frequency is out of range. For more details, see the Application Guideline n. 6. A30808-X3247-L230-3-7619 85 Commands Base Station Controller CML:BSC 5. If the GSUP is FALSE the following attributes must not be specied: GTEMPOFF, GPENTIME, GRESOFF and GHCSPC. 6. The BCCHFREQ attribute related to the serving cell SYSID attribute as follows. They must belong either to the same frequency band or to the complementary bands in the case of dual-band network (GSMDCS, GSMPCS, GSM850PCS). In the following table, the allowed frequency ranges allowed as complementary bands for the ADJC BCCHFREQ attribute depending on BSC NETWTYPE and serving cell SYSID attribute: 7. The maximumnumber of adjacent cells having their BCCHFREQin the complemen- tary band, with respect to the SYSID of the serving cell, depends on the delta between the lowest and the highest frequency of the ADJCs belonging to this subset, as shown in the following table: 8. When creating new ADJC objects it may happen that a TRX issues a failure event report. This leads to a temporary situation where this TRX does not include the NETWTYPE BTS SYSID Complementary Band GSMR GSMR --- GSMDCS BB900 DCS1800 (512..885) EXT900 DCS1800 (512..885) F2ONLY900 DCS1800 (512..885) DCS1800 F2ONLY900( 0..124, 975..1023) GSMDCS bcch(0-124) DCS1800 (512..885) GSMDCS bcch(512-885) BB900 (0..124) GSMPCS BB900 PCS1900 (512..810) EXT900 PCS1900512..810 F2ONLY900 PCS1900512..810 PCS1900 F2ONLY900(0..124, 975..1023) GSM850PCS GSM850 PCS1900 (512..810) PCS1900 GSM850 (128..251) GSM850PCS bcch(128-251) PCS1900 (512..810) GSM850PCS bcch(512-810) GSM850 (128..251) Max Number of ADJC in complementary Band Delta 16 Any 17 Any, if frequency 0 is present 18 512 22 256 29 128 All 111 or frequency in BB900 band 86 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller affected cell in HANDOVER_CONDITION_INDICATION messages. This applies only for the last cell for which the CREATE command was issued and the failure event report was generated. The situation is cleared when BSCperiodically re-trans- mits the system informations to the TRX Example of Command Execution Create ADJC:NAME=BTSM:0/BTS:0/ADJC:0,TGTCELL=BTS:3,RXLEVMIN=12, HOM=69,HOMSOFF=0,HOMDTIME=0,HOMDOFF=0,MICROCELL=FALSE, FHORLMO=0,TIMERFHO=4,PLNC=0,PPLNC=0,LEVONC=0,TINHBAKHO=30, TINHFAIHO=7,GSUP=TRUE,GTEMPOFF=1,GPENTIME=0,GRESOFF=0, GHCSTH=10,GHCSPC=3,FULHOC=TRUE,FULRXLVMOFF=67, TRFHOM=0,BHOFOT=1, LEVHOM=0,USG=SI_2_5, NCGRESOFF=DB00, NCGTEM- POFF=DB00, NCGPENTIME=SEC000, NCC1THADJC=DB05, TRFHORXLV- MOFF=30; DELETE ADJC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS ADJC DELETE ADJC Applicability: Phase 2. Visibility level 2. Command Description: This command deletes an adjacent cells of a given cell. Validity ranges of the object addresses "btsmn", btsn and "adjcn" can be found in Appendix A. System Responses: Application Guidelines: None. DELETE ADJC: NAME=BTSM:btsmn/BTS:btsn/ADJC:adjcn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the SCA object instance related to the BTS is in LOCKED state. A30808-X3247-L230-3-7619 87 Commands Base Station Controller CML:BSC Example of Command Execution Delete ADJC:NAME=BTSM:0/BTS:0/ADJC:0; GET ADJC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMBTS ADJC GET ADJC Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of the parameters, selected by the operator, related to the adjacent cells of a given cell. Validity ranges of the object addresses "btsmn", btsn and "adjcn" can be found in Appendix A. System Responses: GET ADJC: NAME=BTSM:btsmn/BTS:btsn/ADJC:adjcn [,REQATTL=TGTCELL, RXLEVMIN, HOM, HOMSOFF, HOMDTIME, HOMDOFF, MICROCELL, FHORLMO, TIMERFHO, PLNC, PPLNC, LEVONC, TINHBAKHO, TINHFAIHO, GSUP, GTEMPOFF, GPENTIME, GRESOFF, GHCSTH, GHCSPC, FULHOC, FULRXLVMOFF, TRFHOM, BHOFOT, LEVHOM, USG, NCGRESOFF,NCGTEMPOFF, NCGPENTIME, NCC1THADJC, TRFHORXLVMOFF]; GET ACK: TGTCELL: targetCell RXLEVMIN: rxLevMinCell HOM: hoMargin HOMSOFF hoMarginStaticOffset HOMDTIME: hoMarginDelayTime HOMDOFF: hoMarginDynamicOffset MICROCELL: microcell FHORLMO: fHORxLevMinOffset TIMERFHO: timerFHO PLNC: priorityLayerNcel PPLNC: penalityPriorityLayerNcell LEVONC: levelOffsetNcell TINHBAKHO: timerInhibitBackHO TINHFAIHO: timerInhibitFailHO GSUP gprsSupported GTEMPOFF: gprsTemporaryOffset GPENTIME: gprsPenaltyTime 88 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get ADJC:NAME=BTSM:0/BTS:0/ADJC:0,REQATTL=TGTCELL&RXLEVMIN& HOM&HOMSOFF&HOMDTIME&HOMDOFF&MICROCELL&FHORLMO& TIMERFHO&PLNC&PPLNC&LEVONC&TINHBAKHO&TINHFAIHO&GSUP& GTEMPOFF&GPENTIME&GRESOFF&GHCSTH&GHCSPC&FULHOC& FULRXLVMOFF& TRFHOM&BHOFOT&LEVHOM&USG&NCGRESOFF& NCGTEMPOFF&NCGPENTIME&NCC1THADJC&TRFHORXLVMOFF; GET ADJC BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMBTS ADJC GET ADJC BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses "btsmn", btsn and "adjcn" can be found in Appendix A. GRESOFF: gprsReselectOffset GHCSTH: gprsHierarchycalCellStructureThreshold GHCSPC: gprsHierarchycalCellStructPriorityClass FULHOC: fastULHoCell FULRXLVMOFF: fastULRxLevMinOffset TRFHOM: trafficHandoverMargin BHOFOT: backHoForbiddenTimer LEVHOM: levelHOMargin USG: usage NCGRESOFF: ncGprsReselecOffset NCGTEMPOFF: ncGprsTemporaryOffset NCGPENTIME: NcGprsPenaltyTime NCC1THADJC: NcC1ThresholdAdjacent TRFHORXLVMOFF: trafficHoRxLevMinOffset GET NACK: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET ADJC BASICS: NAME=BTSM:btsmn/BTS:btsn/ADJC:adjcn; A30808-X3247-L230-3-7619 89 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Get ADJC BASICS:NAME=BTSM:0/BTS:0/ADJC:0; GET ACK: TGTCELL: targetCell RXLEVMIN: rxLevMinCell HOM: hoMargin HOMSOFF hoMarginStaticOffset HOMDTIME: hoMarginDelayTime HOMDOFF: hoMarginDynamicOffset MICROCELL: microcell FHORLMO: fHORxLevMinOffset TIMERFHO: timerFHO PLNC: priorityLayerNcel PPLNC: penalityPriorityLayerNcell LEVONC: levelOffsetNcell TINHBAKHO: timerInhibitBackHO TINHFAIHO: timerInhibitFailHO GSUP gprsSupported GTEMPOFF: gprsTemporaryOffset GPENTIME: gprsPenaltyTime GRESOFF: gprsReselectOffset GHCSTH: gprsHierarchycalCellStructureThreshold GHCSPC: gprsHierarchycalCellStructPriorityClass FULHOC: fastULHoCell FULRXLVMOFF: fastULRxLevMinOffset TRFHOM: trafficHandoverMargin BHOFOT: backHoForbiddenTimer LEVHOM: levelHOMargin USG: usage NCGRESOFF: ncGprsReselecOffset NCGTEMPOFF: ncGprsTemporaryOffset NCGPENTIME: NcGprsPenaltyTime NCC1THADJC: NcC1ThresholdAdjacent TRFHORXLVMOFF: trafficHoRxLevMinOffset GET NACK: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 90 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SET ADJC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMBTS ADJC SET ADJC Applicability: Phase 2. Visibility level 2. Command Description: This command modifies the specific parameters for adjacent cells of a given cell. Validity ranges of the object addresses "btsmn", btsn and "adjcn" can be found in Appendix A. System Responses: SET ADJC: NAME=BTSM:btsmn/BTS:btsn/ADJC:adjcn [,TGTCELL=] [,RXLEVMIN=] [,HOM=] [,HOMSOFF=] [,HOMDTIME=] [,HOMDOFF=] [,MICROCELL=] [,FHORLMO=] [,TIMERFHO=] [,PLNC=] [,PPLNC=] [,LEVONC=] [,TINHBAKHO=] [,TINHFAIHO=] [,GSUP=] [,GTEMPOFF=] [,GPENTIME=] [,GRESOFF=] [,GHCSTH=] [,GHCSPC=] [,FULHOC=] [,FULRXLVMOFF=] [,TRFHOM=] [,BHOFOT=] [,LEVHOM=] [,USG=] [,NCGRESOFF=] [,NCGTEMPOFF=] [,NCGPENTIME=] [,NCC1THADJC=] [;TRFHORXLVMOFF] SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The BTS object instance must be already equipped. The TGTBTS object instance must be already equipped. If GSUP is TRUE the relative PTPPKF and TGTPTPPKF (for external cells) object instances must be already equipped. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. MAX_ADJC_COMPL_BAND_EXCEEDED The number of the adjacent cells having their BCCHFREQ in the complementary band exceed the allowed maximum number. For more details, see Application Guidelines n. 8. LAST_ADJC_RESERVED_FOR_LOTRACH When the intracell handovers are MSC controlled (attribute LOTRACH of HAND object set at FALSE) one of the 32 allowed ADJCs is reserved by BSCfor LOTRACHhandling, so in this case the operator can configure at most 31 ADJC cells. A30808-X3247-L230-3-7619 91 Commands Base Station Controller CML:BSC Application Guidelines: 1. No administrative state is associated with this object. 2. The attribute penalityPriorityNcell (PPLNC) must be set at a value not smaller than the attributepriorityLayerNcell (PLNC). 3. The timer TIMERFHO is running on the adjacent cell serving the Directed Retry signalling procedure: that is the timer is dened in ADJC A-B for Directed Retry from A to B. 4. The attribute TINHFAIHO should be set at a value greater than the timer BSCT7 (see BSC object) and timer THORQST (see HAND object). 5. If the GSUP is FALSE the following attributes must not be specied: GTEMPOFF, GPENTIME, GRESOFF and GHCSPC. 6. If the related BTS is a GSM(DCS) cell, it is possible to create no more than 16 ADJC MOs in the DCS (GSM) complementary band. 7. The BCCHFREQ attribute related to the serving cell SYSID attribute as follows. They must belong either to the same frequency band or to the complementary bands in the case of dual-band network (GSMDCS, GSMPCS, GSM850PCS). In the following table, the allowed frequency ranges allowed as complementary bands for the ADJC BCCHFREQ attribute depending on BSC NETWTYPE and serving cell SYSID attribute: UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. UNSUCCESSFUL_INVALID_TARGET_CELL The serving cell and the target cell must be different. An ADJC with the same serving and target cell already exist. UNSUCCESSFUL_INVALID_BCCF The target and serving cell must have different BCCH frequency. TOO_MANY_REFERENCES_TO_TARGET_CELL The maximum number of adjacent cells for the target cell (96) has been reached. SUBORDINATE_EQUIPPED In order to set the GSUP parameter at TRUE value, both the serving and the target cells must have the relative PTPPKF already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the SCA object instance related to the BTS is in LOCKED state. UNSUCCESSFUL_BCCF_OUT_OF_RANGE The selected value for the BCCH frequency is out of range. For more details, see the Application Guideline n. 7. NETWTYPE BTS SYSID Complementary Band GSMR GSMR --- GSMDCS BB900 DCS1800 (512..885) EXT900 DCS1800 (512..885) F2ONLY900 DCS1800 (512..885) DCS1800 F2ONLY900( 0..124, 975..1023) GSMDCS bcch(0-124) DCS1800 (512..885) 92 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 8. The maximumnumber of adjacent cells having their BCCHFREQin the complemen- tary band with respect to the serving cells SYSID depends on the delta between the lower and the highest frequency of the ADJC belonging to this subset, as shown in the following table. Example of Command Execution Set ADJC:NAME=BTSM:0/BTS:0/ADJC:0,TGTCELL=BTS:3,RXLEVMIN=12, HOM=69,HOMSOFF=0,HOMDTIME=0,HOMDOFF=0,MICROCELL=FALSE, FHORLMO=0,TIMERFHO=4,PLNC=0,PPLNC=0,LEVONC=0,TINHBAKHO=30, TINHFAIHO=7,GSUP=TRUE,GTEMPOFF=1,GPENTIME=0,GRESOFF=0, GHCSTH=10,GHCSPC=3,FULHOC=TRUE,FULRXLVMOFF=67, TRFHOM=0,BHOFOT=1,LEVHOM=0,USG=SI_2_5, NCGRESOFF=DB00, NCGTEM- POFF=DB00, NCGPENTIME=SEC000, NCC1THADJC=DB05,TRFHORXLV- MOFF=30; GSMDCS bcch(512-885) BB900 (0..124) GSMPCS BB900 PCS1900 (512..810) EXT900 PCS1900512..810 F2ONLY900 PCS1900512..810 PCS1900 F2ONLY900(0..124, 975..1023) GSM850PCS GSM850 PCS1900 (512..810) PCS1900 GSM850 (128..251) GSM850PCS bcch(128-251) PCS1900 (512..810) GSM850PCS bcch(512-810) GSM850 (128..251) Max Number of ADJC in Complementary Band Delta 16 Any 17 Any, if frequency 0 is present 18 512 22 256 29 128 All 111 or frequency in BB900 band NETWTYPE BTS SYSID Complementary Band A30808-X3247-L230-3-7619 93 Commands Base Station Controller CML:BSC ADJC3G CREATE ADJC3G Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS ADJC3G CREATE ADJC3G Applicability: Phase 2. Visibility level 2. Command Description: This command sets the specific parameters for adjacent cells of a given cell. Validity ranges of the object addresses "btsmn", btsn and "adjc3gn" can be found in Appendix A. System Responses: CREATE ADJC3G: NAME=BTSM:btsmn/BTS:btsn/ADJC3G:adjc3gn, TGTCELL= [,USRSCP=] [,USECNO=] [,UMECNO=] [,UADJ=] [,PLNC=] [,PPLNC=] [,RXLEVMINC=] [,HOM=] [,HOMSOFF=] [,HOMDTIME=] [,HOMDOFF=] [,MICROCELL=] [,TINHFAIHO=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The BTS object instance must be already equipped. The TGTFDD (or TGTTDD) object instance pointed by ADJC3G instance must be already equipped. UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_WRONG_ME_ID The TGTCELL must be a TGTFDD object. UNSUCCESSFUL_EXCEED_OBJECT_NBR The maximum number of (ADJC + ADJC3G) for BTS must be lower or equal to 40. The maximum number of ADJC (ADJC + ADJC3G) for system must be greater than or equal to 64 * (MAX_nbr_btse). 94 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Create ADJC3G:NAME=BTSM:0/BTS:0/ADJC3G:0,TGTCELL=TGTFDD:6, USRSCP=9,USECNO=5,UMECNO=44,UADJ=5,PLNC=3,PPLNC=3, RXLEVMINC=33,HOM=111,HOMSOFF=112,HOMDTIME=89,HOMDOFF=56, MICROCELL=TRUE,TINHFAIHO=5; DELETE ADJC3G Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS ADJC3G DELETE ADJC3G Applicability: Phase 2. Visibility level 2. Command Description: This command deletes an adjacent cells of a given cell. Validity ranges of the object addresses "btsmn", btsn and "adjc3gn" can be found in Appendix A. System Responses: UNSUCCESSFUL_INVALID_ATTRIBUTES The NBLKACGR attribute (see BTS object) must be set at a value > 0 when one UTRAN neighbour cell has been configured. For each BTS, it is allowed to create up to 64 ADJC3G instances divided into: - FDD adjacent cells on up to 3 FDD frequencies, with a maximum of 32 cells per frequency; - TDD adjacent cells on up to 3 TDD frequencies, with a maximum of 32 cells per frequency. UNSUCCESSFUL_INVALID_TARGET_CELL An ADJC3G with the same serving and target cell already exists. DELETE ADJC3G: NAME=BTSM:btsmn/BTS:btsn/ADJC3G:adjc3gn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 95 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Delete ADJC3G:NAME=BTSM:0/BTS:0/ADJC3G:0; GET ADJC3G Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS ADJC3G GET ADJC3G Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of the parameters, selected by the operator, related to the adjacent cells of a given cell. Validity ranges of the object addresses "btsmn", btsn and "adjc3gn" can be found in Appendix A. System Responses: GET ADJC3G: NAME=BTSM:btsmn/BTS:btsn/ADJC3G:adjc3gn [,REQATTL=TGTCELL, USRSCP, USECNO, UMECNO, UADJ, PLNC, PPLNC, RXLEVMINC, HOM, HOMSOFF, HOMDTIME, HOMDOFF, MICROCELL, TINHFAIHO]; GET ACK: TGTCELL: targetCell USRSCP: umtsSuffRscp USECNO: umtsSuffEcNo UMECNO: umtsMinEcNo UADJ: umtsAdijust PLNC: priorityLayerNCell PPLNC: penalityPriorityLayerNCell RXLEVMINC: rxLevMinCell HOM: hoMargin HOMSOFF: hoMarginStaticOffset HOMDTIME: hoMarginDelayTime HOMDOFF: hoMarginDynamicOffset MICROCELL: microcell TINHFAIHO: timerInhibitFailHo 96 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get ADJC3G:NAME=BTSM:0/BTS:0/ADJC3G:0,REQATTL=TGTCELL,USRSCP, USECNO,UMECNO,UADJ,PLNC,PPLNC,RXLEVMINC,HOM,HOMSOFF, HOMDTIME,HOMDOFF,MICROCELL,TINHFAIHO; GET ADJC3G BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS ADJC3G GET ADJC3G BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses "btsmn", btsn and "adjc3gn" can be found in Appendix A. System Responses: GET NACK: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET ADJC3G BASICS: NAME=BTSM:btsmn/BTS:btsn/ADJC3G:adjc3gn; GET ACK: TGTCELL: targetCell USRSCP: umtsSuffRscp USECNO: umtsSuffEcNo UMECNO: umtsMinEcNo UADJ: umtsAdijust PLNC: priorityLayerNCell PPLNC: penalityPriorityLayerNCell RXLEVMINC: rxLevMinCell HOM: hoMargin HOMSOFF: hoMarginStaticOffset HOMDTIME: hoMarginDelayTime HOMDOFF: hoMarginDynamicOffset MICROCELL: microcell TINHFAIHO: timerInhibitFailHo A30808-X3247-L230-3-7619 97 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get ADJC3G BASICS:NAME=BTSM:0/BTS:0/ADJC3G:0; SET ADJC3G Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS ADJC3G SET ADJC3G Applicability: Phase 2. Visibility level 2. Command Description: This command modifies the specific parameters for adjacent cells of a given cell. Validity ranges of the object addresses "btsmn", btsn and "adjc3gn" can be found in Appendix A. System Responses: GET NACK: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SET ADJC3G: NAME=BTSM:btsmn/BTS:btsn/ADJC3G:adjc3gn ,TGTCELL= [,USRSCP=] [,USECNO=] [,UMECNO=] [,UADJ=] [,PLNC=] [,PPLNC=] [,RXLEVMINC=] [,HOM=] [,HOMSOFF=] [,HOMDTIME=] [,HOMDOFF=] [,MICROCELL=] [,TINHFAIHO=]; SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The TGTFDD (or TGTTDD) object instance pointed by ADJC3G instance must be already equipped. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_TARGET_CELL An ADJC3G with the same serving and target cell already exists. 98 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Set ADJC3G:NAME=BTSM:0/BTS:0/ADJC3G:0,TGTCELL=TGTFDD:6,USRSCP=9, USECNO=5,UMECNO=44,UADJ=5,PLNC=3,PPLNC=3,RXLEVMINC=33,HOM=111, HOMSOFF=112,HOMDTIME=89,HOMDOFF=56,MICROCELL=TRUE,TINHFAIHO=5; UNSUCCESSFUL_INVALID_ATTRIBUTES For each BTS, it is allowed to create up to 64 ADJC3G instances divided into: - FDD adjacent cells on up to 3 FDD frequencies, with a maximum of 32 cells per frequency; - TDD adjacent cells on up to 3 TDD frequencies, with a maximum of 32 cells per frequency. A30808-X3247-L230-3-7619 99 Commands Base Station Controller CML:BSC ADJCTD The ADJCTD (TD-SCDMA Adjacent Cell) object represents one of the TD-SCDMA adjacent cells that are to be monitored for handover purposes. CREATE ADJCTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD ADJCTD CREATE ADJCTD Applicability: Phase 2. Visibility level 2. Command Description: This command sets the specific parameters for the adjacent cells of a given TD-SCDMA cell. Validity ranges of the object addresses "btsmtdn", btstdn and "adjctdn" can be found in Appendix A. System Responses: CREATE ADJCTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/ADJCTD:adjctdn ,TGTCELL= [,RXLEVMINTD=] [,HOM=] [,FHORLMO=] [,TIMERFHOTD=] [,TINHBAKHO=] [,TINHFAIHO=] [,FHORSCMIO=] [,RSCPMIC=] [,CSYNCHS=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The BTSTD object instance must be already equipped. The TGTBTSTD object instance must be already equipped. UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. UNSUCCESSFUL_INVALID_TARGET_CELL 100 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. No administrative state is associated with this object. 2. The timer TIMERFHOTD is running on the adjacent cell serving the Directed Retry signalling procedure: that is the timer is dened in ADJCTD A-B for Directed Retry from A to B. 3. The attribute TINHFAIHO should be set at a value greater than the timer BSCT7 (see BSC object) and timer THORQSTTD (see HANDTD object). Example of Command Execution Create ADJCTD:NAME=BTSMTD:0/BTSTD:0/ADJCTD:0,TGTCELL=BTSTD:3, RXLEVMINTD=12,HOM=69,FHORLMO=0,TIMERFHOTD=7,TINHBAKHO=30, TINHFAIHO=7, FHORSCMIO=6,RSCPMIC=[-100],CSYNCHS=SYNCHRONIZED; DELETE ADJCTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD ADJCTD DELETE ADJCTD Applicability: Phase 2. Visibility level 2. Command Description: This command deletes an adjacent cells of a given cell. Validity ranges of the object addresses "btsmtdn", btstdn and "adjctdn" can be found in Appendix A. System Responses: Application Guidelines: None. The serving cell and the target cell must be different. An ADJCTD with the same serving and target cell already exist. TOO_MANY_REFERENCES_TO_TARGET_CELL The maximum number of adjacent cells for the target cell (96) has been reached. DELETE ADJCTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/ADJCTD:adjctdn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 101 Commands Base Station Controller CML:BSC Example of Command Execution Delete ADJCTD:NAME=BTSMTD:0/BTSTD:0/ADJCTD:0; GET ADJCTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD ADJCTD GET ADJCTD Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of the parameters, selected by the operator, related to the adjacent cells of a given cell. Validity ranges of the object addresses "btsmtdn", btstdn and "adjctdn" can be found in Appendix A. System Responses: Application Guidelines: None. GET ADJCTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/ADJCTD:adjctdn [,REQATTL=TGTCELL, RXLEVMINTD, HOM, FHORLMO, TIMERFHOTD, TINHBAKHO, TINHFAIHO, FHORSCMIO, RSCPMIC, CSYNCHS]; GET ACK: TGTCELL: targetCell RXLEVMINTD: rxLevMinCellTD HOM: hoMargin FHORLMO: fHORxLevMinOffset TIMERFHOTD: timerFHOTD TINHBAKHO: timerInhibitBackHO TINHFAIHO: timerInhibitFailHO FHORSCMIO: fHORSCPMinOffset RSCPMIC: rSCPMinCell CSYNCHS: cellSynchStatus GET NACK: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 102 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Get ADJCTD:NAME=BTSMTD:0/BTSTD:0/ADJCTD:0,REQATTL=TGTCELL& RXLEVMINTD&HOM&FHORLMO& TIMERFHOTD&TINHBAKHO& TINHFAIHO&FHORSCMIO&RSCPMIC&CSYNCHS; GET ADJCTD BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD ADJCTD GET ADJCTD BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses "btsmtdn", btstdn and "adjctdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get ADJCTD BASICS:NAME=BTSMTD:0/BTSTD:0/ADJCTD:0; GET ADJCTD BASICS: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/ADJCTD:adjctdn; GET ACK: TGTCELL: targetCell RXLEVMINTD: rxLevMinCellTD HOM: hoMargin FHORLMO: fHORxLevMinOffset TIMERFHOTD: timerFHOTD TINHBAKHO: timerInhibitBackHO TINHFAIHO: timerInhibitFailHO FHORSCMIO: fHORSCPMinOffset RSCPMIC: rSCPMinCell CSYNCHS: cellSynchStatus GET NACK: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 103 Commands Base Station Controller CML:BSC SET ADJCTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD ADJCTD SET ADJCTD Applicability: Phase 2. Visibility level 2. Command Description: This command modifies the specific parameters for adjacent cells of a given TD- SCDMA cell. Validity ranges of the object addresses "btsmtdn", btstdn and "adjctdn" can be found in Appendix A. System Responses: Application Guidelines: 1. No administrative state is associated with this object. 2. The timer TIMERFHOTD is running on the adjacent cell serving the Directed Retry signalling procedure: that is the timer is dened in ADJCTD A-B for Directed Retry from A to B. SET ADJCTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/ADJCTD:adjctdn [,TGTCELL=] [,RXLEVMINTD=] [,HOM=] [,FHORLMO=] [,TIMERF- HOTD=] [,TINHBAKHO=] [,TINHFAIHO=] [,FHORSCMIO=] [,RSCPMIC=] [,CSYNCHS=]; SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The BTSTD object instance must be already equipped. The TGTBTSTD object instance must be already equipped. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. UNSUCCESSFUL_INVALID_TARGET_CELL The serving cell and the target cell must be different. An ADJCTD with the same serving and target cell already exist. TOO_MANY_REFERENCES_TO_TARGET_CELL The maximum number of adjacent cells for the target cell (96) has been reached. 104 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 3. The attribute TINHFAIHO should be set at a value greater than the timer BSCT7 (see BSC object) and timer THORQST (see HANDTD object). Example of Command Execution Set ADJCTD:NAME=BTSMTD:0/BTSTD:0/ADJCTD:0,TGTCELL=BTSTD:3, RXLEVMINTD=12,HOM=69,FHORLMO=0,TIMERFHOTD=7,TINHBAKHO=30, TINHFAIHO=7, FHORSCMIO=6,RSCPMIC=[-100],CSYNCHS=SYNCHRONIZED; A30808-X3247-L230-3-7619 105 Commands Base Station Controller CML:BSC AIRTSTD The AIRTSTD (Air Timeslot) represents the radio time slot in which the radio carrier is subdivided by time sharing on the TD-SCDMA air interface; it can be uplink or downlink. CREATE AIRTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD AIRTSTD CREATE AIRTSTD Applicability: Phase 2. Visibility level 2. Command Description: This command defines an instance of the functional object that models the manageable characteristics of a radio time slot on the TD-SCDMA air interface. Seven instances of this functional object are contained by one instance of the TRXTD functional object. A TD-SCDMA air timeslot can carry several combinations of logical channels and it is described with radio time slot attributes (e.g. Downlink/Uplink direction). Validity ranges of the object addresses btsmtdn, "btstdn", "trxtdn" and "airtstdn" can be found in Appendix A. System Responses: Application Guidelines: 1. The AIRTSTD instance is equal to the TimeSlot subeld of the PFACHDESC attribute (BTSTD object) and the following values: MANOUSRTS (maxNofUserPerTS belonging to BTSTD object), CREATE AIRTSTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn/ AIRTSTD:airtstdn [,PREFSF=], DEFPRI=; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The TRXTD which the channel belongs to must be equipped. The tsln 0 of a pcmb line is used for synchronism. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. For more details see Application Guidelines n. 1, n. 2, n. 3. 106 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TSC subeld of PFACHDESC parameter (BTSTD object), PREFSF (preferredSF; AIRTSTD object), do not fulll the requirements, dened in OVSF code tree, in order to determinate a proper Spreading Code. 2. The AIRTSTD instance is equal to the TimeSlot subeld of the SCCPCHDESC attribute (BTSTD object) and the following values: MANOUSRTS (maxNofUserPerTS belonging to BTSTD object), TSC subeld of SCCPCHDESC parameter (BTSTD object), PREFSF (preferredSF; AIRTSTD object), do not fulll the requirements, dened in OVSF code tree, in order to determinate a proper Spreading Code. 3. If the AIRTSTD object instance is equal to the TimeSlot subeld of the PFACH- DESC attribute of the superordinate BTSTD: if the SC subeld of the PFACHDESCattribute belongs to the range [0..15], then the PREFSF parameter must be equal to either ALL_SF_16 or DYNAMIC_SF; if the SC subeld of the PFACHDESC attribute belongs to the range [16..23], then the PREFSF parameter must be equal to either ALL_SF_8 or DYNAMIC_SF. Example of Command Execution Create AIRTSTD:NAME=BTSMTD:0/BTSTD:0/TRXTD:0/AIRTSTD:0, PREFSF=SF_DYNAMIC, DEFPRI=100; DELETE AIRTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD AIRTSTD DELETE AIRTSTD Applicability: Phase 2. Visibility level 2. Command Description: This command deletes an instance of the object that manages a TD-SCDMA radio resource, previously created through the CREATE AIRTSTD command. Validity ranges of the object addresses btsmtdn, "btstdn", "trxtdn" and "airtstdn" can be found in Appendix A. System Responses: DELETE AIRTSTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn/ AIRTSTD:airtstdn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED A30808-X3247-L230-3-7619 107 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Delete AIRTSTD:NAME=BTSMTD:0/BTSTD:0/TRXTD:0/AIRTSTD:0; GET AIRTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD AIRTSTD GET AIRTSTD Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the parameter values of a AIRTSTD previously created through the CREATE AIRTSTD command. Validity ranges of the object addresses btsmtdn, "btstdn", "trxtdn" and "airtstdn" can be found in Appendix A. System Responses: Application Guidelines: None. The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a AIRTSTD, the relative object instance must be in LOCKED state. GET AIRTSTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn/ AIRTSTD:airtstdn [,REQATTL= PREFSF, DEFPRI]; GET ACK: NAME: name PREFSF: preferredSF DEFPRI: defaultPriority GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 108 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Get AIRTSTD:NAME=BTSMTD:0/BTSTD:0/TRXTD:0/AIRTSTD:0, REQATTL=PREFSF& DEFPRI; GET AIRTSTD BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD AIRTSTD GET AIRTSTD BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses btsmtdn, "btstdn", "trxtdn" and "airtstdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get AIRTSTD BASICS:NAME=BTSMTD:0/BTSTD:0/TRXTD:0/AIRTSTD:0; GET AIRTSTD BASICS: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn/ AIRTSTD:airtstdn; GET ACK: NAME: name PREFSF: preferredSF DEFPRI: defaultPriority GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 109 Commands Base Station Controller CML:BSC GET AIRTSTD STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD AIRTSTD GET AIRTSTD STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the AIRTSTD object: Administrative State (AST) Operational State (OST) Usage State (UST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). Validity ranges of the object addresses btsmtdn, "btstdn", "trxtdn" and "airtstdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get AIRTSTD STAT:NAME=BTSMTD:0/BTSTD:0/TRXTD:0/AIRTSTD:0; GET AIRTSTD STAT: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn/ AIRTSTD:airtstdn; GET AIRTSTD STAT ACK: GET AIRTSTD STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 110 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETRELATIONSHIP AIRTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD AIRTSTD GETRELATIONSHIP AIRTSTD Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO(Functional Managed Object); the relationship information consists of all the HMOs (Hardware Managed Object) supporting the FMO functionality. For the AIRTSTD object the related HMOs are the following: LICD/LICDS, EPWR, PPXT, PWRD, MPCC, TDPC, MEMT, NTW, and all the BTSEC HMOs that implement the TRXTD functionality for a certain BTSTD. Validity ranges of the object addresses btsmtdn, "btstdn", "trxtdn" and "airtstdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship AIRTSTD:NAME=BTSMTD:0/BTSTD:0/TRXTD:0/AIRTSTD:0; GETRELATIONSHIP AIRTSTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtd n/AIRTSTD:airtstdn; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. A30808-X3247-L230-3-7619 111 Commands Base Station Controller CML:BSC GETSUBO AIRTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD AIRTSTD GETSUBO AIRTSTD Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. Validity ranges of the object addresses btsmtdn, "btstdn", "trxtdn" and "airtstdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo AIRTSTD:NAME=BTSMTD:0/BTSTD:0/TRXTD:0/AIRTSTD:0; LOCK AIRTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD AIRTSTD LOCK AIRTSTD Applicability: Phase 2. GETSUBO AIRTSTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn/ AIRTSTD:airtstdn; GETSUBO AIRTSTD ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end a message is displayed notifying the end of the subordinate list. GETSUBO AIRTSTD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK AIRTSTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn/ AIRTSTD:airtstdn; 112 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". Validity ranges of the object addresses btsmtdn, "btstdn", "trxtdn" and "airtstdn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock AIRTSTD:NAME=BTSMTD:0/BTSTD:0/TRXTD:0/AIRTSTD:0; SET AIRTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD AIRTSTD SET AIRTSTD Applicability: Phase 2. Visibility level 2. Command Description: This command modifies the attributes of a radio timeslot on the TD-SCDMA air inter- face. Validity ranges of the object addresses btsmtdn, "btstdn", "trxtdn" and "airtstdn" can be found in Appendix A. LOCK AIRTSTD ACK: LOCK AIRTSTD NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SET AIRTSTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn/ AIRTSTD:airtstdn [,PREFSF=] [,DEFPRI=]; A30808-X3247-L230-3-7619 113 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: 1. The AIRTSTD instance is equal to the TimeSlot subeld of the PFACHDESC attribute (BTSTD object) and the following values: MANOUSRTS (maxNofUserPerTS belonging to BTSTD object), TSC subeld of PFACHDESC parameter (BTSTD object), PREFSF (preferredSF; AIRTSTD object), do not fulll the requirements, dened in OVSF code tree, in order to determinate a proper Spreading Code. 2. The AIRTSTD instance is equal to the TimeSlot subeld of the SCCPCHDESC attribute (BTSTD object) and the following values: MANOUSRTS (maxNofUserPerTS belonging to BTSTD object), TSC subeld of SCCPCHDESC parameter (BTSTD object), PREFSF (preferredSF; AIRTSTD object), do not fulll the requirements, dened in OVSF code tree, in order to determinate a proper Spreading Code. 3. If the AIRTSTD object instance is equal to the TimeSlot subeld of the PFACH- DESC attribute of the superordinate BTSTD: if the SC subeld of the PFACHDESCattribute belongs to the range [0..15], then the PREFSF parameter must be equal to either ALL_SF_16 or DYNAMIC_SF; if the SC subeld of the PFACHDESC attribute belongs to the range [16..23], then the PREFSF parameter must be equal to either ALL_SF_8 or DYNAMIC_SF. Example of Command Execution Set AIRTSTD:NAME=BTSMTD:0/BTSTD:0/TRXTD:0/AIRTSTD:0, PREFSF=SF_DYNAMIC, DEFPRI=100; SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. For more details see Application Guidelines n. 1, n. 2, n. 3. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The superordinate TRXTD object instance must be equipped. UNSUCCESSFUL_INVALID_STATUS The AIRTSTD object instance, on which the Common Channels P- RACH, P-FACH and S-CCPCH are located, must be locked if the PREFSF (preferredSF) attribute must be changed. 114 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SHUTDOWN AIRTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD AIRTSTD SHUTDOWN AIRTSTD Applicability: Phase 2. Visibility level 1. Command Description: This command allows the graceful transition of an object from the administrative state "Unlocked" to the administrative state "Locked" after the object has terminated its current activity. The BSSis able to force a UEto performan intracell, intercell or inter-BSCHOby means of the O&M SHUTDOWN command. After the SHUTDOWN command is entered, the systemtries to performan intracell, intercell or inter-BSC HOper mobile station; in case of failure, a further attempt is performed every 30 seconds for the next 5 minutes period. If after the predefined period (5.5 minutes) the current activity is not terminated, the administrative state will be set at Locked. If one of the objects is still active or busy after the predefined period, ongoing calls will be dropped. Validity ranges of the object addresses btsmtdn, "btstdn", "trxtdn" and "airtstdn" can be found in Appendix A. System Responses: Application Guidelines: 1. If the operator has started too many shutdown commands, the system will display the SM TOO BUSY message. 2. Possible state transitions and timing: a) UNLOCKED -immediately-> SHUTTING DOWN ---------- immediately ----------> LOCKED b) UNLOCKED -immediately-> SHUTTING DOWN ---------- 5.5 minutes ----------> LOCKED c) UNLOCKED -immediately-> SHUTTING DOWN ---------- after object went to idle state ----------> LOCKED SHUTDOWN AIRTSTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn/AI RTSTD:airtstdn; SHUTDOWN AIRTSTD ACK: SHUTDOWN AIRTSTD NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 115 Commands Base Station Controller CML:BSC The state changes described above show all the possible transitions when the shut- down command was performed. The rst column of the table gives the situations which are affected by doing a shutdown of an object. Example of Command Execution Shutdown AIRTSTD:NAME=BTSMTD:0/BTSTD:0/TRXTD:0/AIRTSTD:0; UNLOCK AIRTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD AIRTSTD UNLOCK AIRTSTD Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". Validity ranges of the object addresses btsmtdn, "btstdn", "trxtdn" and "airtstdn" can be found in Appendix A. System Responses: Application Guidelines: None. SITUATIONS TRANSITIONS FORCED/NOT FORCED idle object a) busy object but not released after the SHUTDOWN command b) busy object but released after the SHUTDOWN command c) UNLOCK AIRTSTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn/ AIRTSTD:airtstdn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 116 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Unlock AIRTSTD:NAME=BTSMTD:0/BTSTD:0/TRXTD:0/AIRTSTD:0; A30808-X3247-L230-3-7619 117 Commands Base Station Controller CML:BSC BSC The BSC (Base Station Controller) object represents the controller of the BTS equipments. GET BSC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC GET BSC Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the global parameters, previously entered through the SET BSC command, or the default values if the SET BSC command was not submitted. The validity range of the object address "bscn" can be found in Appendix A. GET BSC: NAME=BSC:bscn [,REQATTL=NETWTYPE, T3122, ERRACT, ENCALSUP, BSCTYP, MAXNCELL, MSCV, OVLSTTHR, OVLENTHR, BSCOVLH, BTSOVLH, MSCOVLH, EISDCCHHO, ENFORCHO, NTWCARD, AMONTH, ASMONTH, SPENLAW, PCMTYPE, EFRSUPP, CICFM, EPOOL, MSCPOOL, HRSPEECH, HRDATA, SPEED145, ENHSCSD, ENFOIAHO, HOSYNC, ASUBENCAP, ASUBISAT, AISAT, EPREHSCSD, MAFIRACHO, MADGRLV, NOTFACCH, MNTBMASK, DLAPDOVL, MEDAFUST, MEDAFUPE, MASCLOGFS, IMSIFSIZ, CFS, ALRMSEVBTS, ALRMSEVBTSM, ALRMSEVCBCL, ALRMSEVLPDLM, ALRMSEVLPDLR, ALRMSEVLPDLS, ALRMSEVOMAL, ALRMSEVPCMA, ALRMSEVPCMB, ALRMSEVPCMS, ALRMSEVTRAU, ALRMSEVTRX, ALRMSEVPCU, ALRMSEVFRL, ALRMSEVNSVC, ALRMSEVPTPPKF, ALRMSEVPCMG, ALRMSEVBTSMTD, ALRMSEVBTSTD, ALRMSEVLPDLMTD, ALRMSEVLPDLRTD, ALRMSEVPCUTD, ALRMSEVPTPPKFTD, ALRMSEVTDCU, ALRMSEVTRXTD, BSCT1, BSCT3, BSCT4, BSCT7, BSCT8, BSCT10, BSCT11, BSCT13, BSCT17, BSCT18, BSCT19, BSCT20, BSCTQHO, BSCT3121, TCBCSI, TRACEMR, TRACEMG, TRFCT, EPA, CBCPH, TGUARDTCHSD, CPOLICY, DGRSTRGY, CITASUP, LCSNSSC, LCSMONTH, SIMSCREL99, TRFPS, NCRESELFLAG, CSCH3CSCH4SUP, UPGRFREQ, ACCEPTGDEGR, EUSDCHO, ALRMSEVIPLI, ESUP, SISGSNREL99, NECI, ASCIONECHMDL, EHRACTAMR]; 118 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: GET ACK: NAME: name NETWTYPE: networkType T3122: waitIndication ERRACT: errorAct ENCALSUP: encalg1 encalg2 encalg3 encalg4 encalg5 encalg6 encalg7 encalg8 encalg9 encalg10 BSCTYP: bscType (read only parameter) MAXNCELL: maxNCel MSCV: mscVersion OVLSTTHR: ovlStartThreshold OVLENTHR: ovlEndThreshold BSCOVLH: bscOvlHand BTSOVLH: btsOvlHand MSCOVLH: mscOvlHand EISDCCHHO: enableInterSdcchHo ENFORCHO: enforceHo NTWCARD: networkCard AMONTH: aintTchMonitorThresholds ASMONTH: aintSs7MonitorThresholds SPENLAW: speechEncodingLaw PCMTYPE: pcmType EFRSUPP: enhancedFullRateSupport CICFM: cicFormat EPOOL: enablePooling MSCPOOL: mscPooling HRSPEECH: halfRateSpeechSupported HRDATA: halfRateDataSupported SPEED145: speedSupported_14_5 ENHSCSD: enableHSCSD ENFOIAHO: enableForcedIntraCellHo HOSYNC: handoverSynchronization ASUBENCAP: AsubEnancedCapacityAllowed ASUBISAT: sbsAsubInterfacelsSatellited AISAT: sbsAInterfacelsSatellited EPREHSCSD: enablePreemptionHSCSD MAFIRACHO: maxForcedIntraCellHO MADGRLV: maxDowngradeLevel A30808-X3247-L230-3-7619 119 Commands Base Station Controller CML:BSC NOTFACCH: notificationOnFACCH MNTBMASK: maintenanceBitMask DLAPDOVL: dowlinkLapdOverload MEDAFUST: measurementDataFileUploadStart MEDAFUPE: measurementDataFileUploadPeri MASCLOGFS: MaxScannerLogFileSize IMSIFSIZ: imsiFileSize CFS: ctrFileSize ALRMSEVBTS: alarmSeverityBts ALRMSEVBTSM: alarmSeverityBtsm ALRMSEVCBCL: alarmSeverityCbcl ALRMSEVLPDLM: alarmSeverityLpdlm ALRMSEVLPDLR: alarmSeverityLpdlr ALRMSEVLPDLS: alarmSeverityLpdls ALRMSEVOMAL: alarmSeverityOmal ALRMSEVPCMA: alarmSeverityPcma ALRMSEVPCMB: alarmSeverityPcmb ALRMSEVPCMS: alarmSeverityPcms ALRMSEVTRAU: alarmSeverityTrau ALRMSEVTRX: alarmSeverityTrx ALRMSEVPCU: alarmSeverityPcu ALRMSEVFRL: alarmSeverityFrl ALRMSEVNSVC: alarmSeverityNsvc ALRMSEVPTPPKF: alarmSeverityPtppkf ALRMSEVPCMG: alarmSeverityPcmg ALRMSEVBTSMTD: alarmSeverityBtsmtd ALRMSEVBTSTD: alarmSeverityBtstd ALRMSEVLPDLMTD: alarmSeverityLpdlmtd ALRMSEVLPDLRTD: alarmSeverityLpdlrtd ALRMSEVPCUTD: alarmSeverityPcutd ALRMSEVPTPPKFTD: alarmSeverityPtppkftd ALRMSEVTDCU: alarmSeverityTdcu ALRMSEVTRXTD: alarmSeverityTrxtd BSCT1: bscTimer1 BSCT3: bscTimer3 BSCT4: bscTimer4 BSCT7: bscTimer7 BSCT8: bscTimer8 BSCT10: bscTimer10 BSCT11: bscTimer11 BSCT13: bscTimer13 BSCT17: bscTimer17 BSCT18: bscTimer18 BSCT19: bscTimer19 BSCT20: bscTimer20 BSCTQHO: bscTimerQueueHo BSCT3121 bscTimer3121 120 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get BSC:NAME=BSC:0,REQATTL=NETWTYPE&T3122&ERRACT&ENCALSUP& BSCTYP&MAXNCELL&MSCV&OVLSTTHR&OVLENTHR&BSCOVLH& BTSOVLH&MSCOVLH&EISDCCHHO&ENFORCHO&NTWCARD&AMONTH& ASMONTH&SPENLAW&PCMTYPE&EFRSUPP&CICFM&EPOOL&MSCPOOL& HRSPEECH&HRDATA&SPEED145&ENHSCSD&ENFOIAHO&HOSYNC& ASUBENCAP&ASUBISAT&AISAT&EPREHSCSD&MAFIRACHO& MADGRLV&NOTFACCH&MNTBMASK&DLAPDOVL&MEDAFUST&MEDAFUPE& MASCLOGFS&IMSIFSIZ&CFS&ALRMSEVBTS&ALRMSEVBTSM& ALRMSEVCBCL&ALRMSEVLPDLM&ALRMSEVLPDLR&ALRMSEVLPDLS& ALRMSEVOMAL&ALRMSEVPCMA&ALRMSEVPCMB&ALRMSEVPCMS& ALRMSEVTRAU&ALRMSEVTRX&ALRMSEVPCU&ALRMSEVFRL& ALRMSEVNSVC&ALRMSEVPTPPKF&ALRMSEVPCMG&ALRM- SEVBTSMTD&ALRMSEVBTSTD&ALRMSEVLPDLMTD&ALRMSEVLP- DLRTD&ALRMSEVPCUTD&ALRMSEVPTPPKFTD&ALRMSEVTDCU, ALRMSEVTRXTDBSCT1&BSCT3& BSCT4&BSCT7&BSCT8&BSCT10& TCBCSI: timerForCBCServiceInterruption TRACEMR: traceMeasureReport TRACEMG: traceMeasureGranularity TRFCT: trafficControlTimer EPA: enablePairing: CBCPH: CBCphase TGUARDTCHSD: timerGuardTchsd CPOLICY: callPolicy DGRSTRGY: downgradeStrategy CITASUP: cellIdTimeAdvSupport LCSNSSC: lcsNssCentric LCSMONTH: lCSMonitorTresholds SIMSCREL99: systemInfoMscRel99 TRFPS trafficPs NCRESELFLAG ncReselectionFlag CSCH3CSCH4SUP: codingScheme3CodingScheme4Support UPGRFREQ: UpgradeFrequency Uplink Downlink ACCEPTGDEGR: acceptableGPRSDegradation EUSDCHO: enableUmtsSdcchHo ALRMSEVIPLI: alarmSeverityIpli ESUP: edgeSupport SISGSNREL99: systemInfoSgsnRelease99 NECI newEstablishCauseIndication ASCIONECHMDL asciOneChannelModel EHRACTAMR enableHrActivationAmr A30808-X3247-L230-3-7619 121 Commands Base Station Controller CML:BSC BSCT11&BSCT13&BSCT17&BSCT18&BSCT19&BSCT20&BSCTQHO&BSCT3121& TCBCSI&TRACEMR&TRACEMG&TRFCT&EPA&CBCPH&TGUARDTCHSD&CPOLI CY&DGRSTRGY&CITASUP&LCSNSSC&LCSMONTH&SIMSCREL99&TRFPS&NCR ESELFLAG&CSCH3CSCH4SUP&UPGRFREQ&ACCEPTGDEGR&EUSDCHO& ALRMSEVIPLI&ESUP&SISGSNREL99 &NECI&ASCIONECHMDL&EHRACTAMR; GET BSC ALARMSEV Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC GET BSC ALARMSEV Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the SEVERITY group. The validity range of the object address "bscn" can be found in Appendix A. System Responses: GET BSC ALARMSEV: NAME=BSC:bscn, GET ACK: NAME: name ALRMSEVBTS: alarmSeverityBts ALRMSEVBTSM: alarmSeverityBtsm ALRMSEVCBCL: alarmSeverityCbcl ALRMSEVLPDLM: alarmSeverityLpdlm ALRMSEVLPDLR: alarmSeverityLpdlr ALRMSEVLPDLS: alarmSeverityLpdls ALRMSEVOMAL: alarmSeverityOmal ALRMSEVPCMA: alarmSeverityPcma ALRMSEVPCMB: alarmSeverityPcmb ALRMSEVPCMS: alarmSeverityPcms ALRMSEVTRAU: alarmSeverityTrau ALRMSEVTRX: alarmSeverityTrx ALRMSEVPCU: alarmSeverityPcu ALRMSEVFRL: alarmSeverityFrl ALRMSEVNSVC: alarmSeverityNsvc ALRMSEVPTPPKF: alarmSeverityPtppkf ALRMSEVPCMG: alarmSeverityPcmg ALRMSEVBTSMTD: alarmSeverityBtsmtd ALRMSEVBTSTD: alarmSeverityBtstd ALRMSEVLPDLMTD: alarmSeverityLpdlmtd ALRMSEVLPDLRTD: alarmSeverityLpdlrtd 122 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get BSC ALARMSEV:NAME=BSC:0; GET BSC BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC GET BSC BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "bscn" can be found in Appendix A. System Responses: ALRMSEVPCUTD: alarmSeverityPcutd ALRMSEVPTPPKFTD: alarmSeverityPtppkftd ALRMSEVTDCU: alarmSeverityTdcu ALRMSEVTRXTD: alarmSeverityTrxtd GET BSC BASICS: NAME=BSC:bscn, GET ACK: NAME: name NETWTYPE: networkType T3122: waitIndication ERRACT: errorAct ENCALSUP: encalg1 encalg2 encalg3 encalg4 encalg5 encalg6 encalg7 encalg8 encalg9 encalg10 BSCTYP: bscType (read only parameter) MAXNCELL: maxNCel MSCV: mscVersion OVLSTTHR: ovlStartThreshold A30808-X3247-L230-3-7619 123 Commands Base Station Controller CML:BSC OVLENTHR: ovlEndThreshold BSCOVLH: bscOvlHand BTSOVLH: btsOvlHand MSCOVLH: mscOvlHand EISDCCHHO: enableInterSdcchHo ENFORCHO: enforceHo NTWCARD: networkCard AMONTH: aintTchMonitorThresholds ASMONTH: aintSs7MonitorThresholds SPENLAW: speechEncodingLaw PCMTYPE: pcmType EFRSUPP: enhancedFullRateSupport CICFM: cicFormat EPOOL: enablePooling MSCPOOL: mscPooling HRSPEECH: halfRateSpeechSupported HRDATA: halfRateDataSupported SPEED145: speedSupported_14_5 ENHSCSD: enableHSCSD ENFOIAHO: enableForcedIntraCellHo HOSYNC: handoverSynchronization ASUBENCAP: AsubEnancedCapacityAllowed ASUBISAT: sbsAsubInterfacelsSatellited AISAT: sbsAInterfacelsSatellited EPREHSCSD: enablePreemptionHSCSD MAFIRACHO: maxForcedIntraCellHO MADGRLV: maxDowngradeLevel NOTFACCH: notificationOnFACCH MNTBMASK: maintenanceBitMask DLAPDOVL: dowlinkLapdOverload TRACEMG: traceMeasureGranularity TRFCT: trafficControlTimer EPA: enablePairing: CBCPH: CBCphase TGUARDTCHSD: timerGuardTchsd CPOLICY: callPolicy DGRSTRGY: downgradeStrategy CITASUP: cellIdTimeAdvSupport LCSNSSC: lcsNssCentric LCSMONTH: lCSMonitorTresholds SIMSCREL99: systemInfoMscRel99 TRFPS trafficPs NCRESELFLAG ncReselectionFlag CSCH3CSCH4SUP: codingScheme3CodingScheme4Support UPGRFREQ: UpgradeFrequency Uplink Downlink 124 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get BSC BASICS:NAME=BSC:0; GET BSC CONTROL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC GET BSC CONTROL Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the CONTROL group. The validity range of the object address "bscn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get BSC CONTROL:NAME=BSC:0; ACCEPTGDEGR: acceptableGPRSDegradation ESUP: edgeSupport SISGSNREL99: systemInfoSgsnRelease99 NECI newEstablishCauseIndication ASCIONECHMDL asciOneChannelModel EHRACTAMR enableHrActivationAmr GET BSC CONTROL: NAME=BSC:bscn, GET ACK: NAME: name MEDAFUST: measurementDataFileUploadStart MEDAFUPE: measurementDataFileUploadPeri MASCLOGFS: MaxScannerLogFileSize IMSIFSIZ: imsiFileSize CFS: ctrFileSize A30808-X3247-L230-3-7619 125 Commands Base Station Controller CML:BSC GET BSC STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSC GET BSC STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the alarm status (ALS) of the BSC object. The validity range of the object address "bscn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get BSC STAT:NAME=BSC:0; GET BSC STAT: NAME=BSC:bscn; GET BSC STAT ACK: GET BSC STAT NACK: NACK CAUSES: 126 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET BSC TIMER Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC GET BSC TIMER Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the TIMER group. The validity range of the object address "bscn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get BSC TIMER:NAME=BSC:0; GET BSC TIMER: NAME=BSC:bscn, GET ACK: NAME: name BSCT1: bscTimer1 BSCT3: bscTimer3 BSCT4: bscTimer4 BSCT7: bscTimer7 BSCT8: bscTimer8 BSCT10: bscTimer10 BSCT11: bscTimer11 BSCT13: bscTimer13 BSCT17: bscTimer17 BSCT18: bscTimer18 BSCT19: bscTimer19 BSCT20: bscTimer20 BSCTQHO: bscTimerQueueHo BSCT3121 bscTimer3121 A30808-X3247-L230-3-7619 127 Commands Base Station Controller CML:BSC GETLOCKED BSC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC GETLOCKED BSC Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the list of BSC locked objects. The validity range of the object address "bscn" can be found in Appendix A. System Responses: Application Guidelines: The system response is organized to have up to 10 MEID of locked objects in a message. Example of Command Execution Getlocked BSC:NAME=BSC:0; MEMDUMP BSC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC MEMDUMP BSC Applicability: Phase 2. Visibility level 2. GETLOCKED BSC: NAME=BSC:bscn; Get Locked Object List Response BSC: name = BSC:0 lockedObjectList ObjPath ... ObjPath MEMDUMP BSC: NAME=BSC:bscn, TYPPROC=, PHYADDR=, ACCTYP=, LEND=; 128 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: The command allows the operator to get on line information about contents of memory locations. Proper check will be executed to grant that the access to the specified address is executable according the specified format without cause damage to the system (not all addressable areas are in fact accessible in every format). The validity range of the object address "bscn" can be found in Appendix A. System Responses: MEMDUMP BSC ACK: Message: PROCESSOR MAINTENANCE--> LMT LOCAL MON. JAN. 01 1990 00:16:12 *** RESPONSE *** MEMORY DUMP DATA name = BSC:0 Type Processor: MPCC_ACT Physical Address: HD00000 Alarm state: H0 dumpData = H00 H01 H02 H03 H04 H05 H06 H07 H08 H09 H0A H0B H0C H0D H0E H0F H10 H11 H12 H13 H14 H15 H16 H17 H18 H19 H1A H1B H1C H1D H1E H1F H20 H21 H22 H23 or in case of WORD access the format must be: Message: PROCESSOR MAINTENANCE --> LMT LOCAL MON. JAN. 01 1990 00:16:12 *** RESPONSE *** MEMORY DUMP DATA name = BSC:0 Type Processor: MPCC_ACT Physical Address: HD00000 Alarm state: H0 dumpData = H0100 H0302 H0504 H0706 H0908 H0b0a H0d0c H0f0e H1110 H1312 H1514 H1716 H1918 H1b1a H1d1c H1f1e 2120 2322 or in case of DWORD access the format must be: Message: PROCESSOR MAINTENANCE --> LMT LOCAL MON. JAN. 01 1990 00:16:12 *** RESPONSE *** MEMORY DUMP DATA name = BSC:0 Type Processor: MPCC_ACT Physical Address: HD00000 Alarm state: H0 dumpData = A30808-X3247-L230-3-7619 129 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Memdump BSC:NAME=BSC:0,TYPPROC=MPCC_ACT,PHYADDR=D00000, ACCTYP=BYTE,LEND=36; H03020100 H07060504 H0b0a0908 H0f0e0d0c H13121110 H17161514 H1b1a1918 H1f1e1d1c NACK CAUSES: PROCESSOR OUT OF SERVICE The command is not performed because issued against an out of service processor. INVALID HARDWARE REGION The command is not performed because issued against an invalid hardware region (i.e. hardware not implemented). INAVLID HARDWARE ACCESS MODE The command is not performed because issued against an invalid hardware region but with the wrong access type. 130 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SET BSC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC SET BSC Applicability: Phase 2. Visibility level 2. Command Description: This command sets the global parameters for BSC. The validity range of the object address "bscn" can be found in Appendix A. SET BSC: NAME=BSC:bscn [,NETWTYPE=] [,T3122=] [,ERRACT=] [,ENCALSUP=] [,MAXNCELL=] [,MSCV=] [,OVLSTTHR=] [,OVLENTHR=] [,BSCOVLH=] [,BTSOVLH=] [,MSCOVLH=] [,EISDCCHHO=] [,ENFORCHO=] [,NTWCARD=] [,AMONTH=] [,ASMONTH=] [,SPENLAW=] [,PCMTYPE=] [,EFRSUPP=] [,CICFM=] [,EPOOL=] [,MSCPOOL=] [,HRSPEECH=] [,SPEED145=] [,ENHSCSD=] [,ENFOIAHO=] [,HOSYNC=] [,ASUBENCAP=] [,ASUBISAT=] [,AISAT=] [,EPREHSCSD=] [,MAFIRACHO=] [,MADGRLV=] [,NOTFACCH=] [,MNTBMASK=] [,DLAPDOVL=] [,TCBCSI=] [,TRACEMR=] [,TRACEMG=] [,TRFCT=] [,EPA=] [,CBCPH=] [,TGUARDTCHSD=] [,CPOLICY=] [,DGRSTRGY=] [,CITASUP=] [,LCSNSSC=] [,LCSMONTH=] [,MEDAFUST=] [,MEDAFUPE=] [,MASCLOGFS=] [,IMSIFSIZ=] [,CFS=] [,ALRMSEVBTS=] [,ALRMSEVBTSM=] [,ALRMSEVCBCL=] [,ALRMSEVLPDLM=] [,ALRMSEVLPDLR=] [,ALRMSEVLPDLS=] [,ALRMSEVOMAL=] [,ALRMSEVPCMA=] [,ALRMSEVPCMB=] [,ALRMSEVPCMS=] [,ALRMSEVTRAU=] [,ALRMSEVTRX=] [,ALRMSEVPCU=] [,ALRMSEVFRL=] [,ALRMSEVNSVC=] [,ALRMSEVPTPPKF=] [,ALRMSEVPCMG=] [,ALRMSEVBTSMTD=] [,ALRMSEVBTSTD=] [,ALRMSEVLPDLMTD=] [,ALRMSEVLPDLRTD=] [,ALRMSEVPCUTD=] [,ALRMSEVPTPPKFTD=] [,ALRMSEVTDCU=] [,ALRMSEVTRXTD=] [,BSCT1=] [,BSCT3=] [,BSCT4=] [,BSCT7=] [,BSCT8=] [,BSCT10=] [,BSCT11=] [,BSCT13=] [,BSCT17=] [,BSCT18=] [,BSCT19=] [,BSCT20=] [,BSCTQHO=] [,BSCT3121=] [,SIMSCREL99=] [,TRFPS=] [,NCRESELFLAG=] [,CSCH3CSCH4SUP=] [,UPGR- FREQ=] [,ACCEPTGDEGR=] [,EUSDCHO=] [,ALRM- SEVIPLI=] [,ESUP=] [,SISGSNREL99=] [,NECI=] [,ASCIONECHMDL][,EHRACTAMR=]; A30808-X3247-L230-3-7619 131 Commands Base Station Controller CML:BSC System Responses: SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_ATTRIBUTES Make reference to Application Guidelines n. 5, n. 8, n. 11, n. 14, n. 15, n. 16, n. 18, n. 19, n. 20, n. 21, n. 22, n. 23, n. 31, n. 33, n. 35, n.36, n.37, n.38. SUBORDINATE_EQUIPPED Make reference to Application Guidelines n. 4, n. 6, n. 9, n. 10, n. 32. UNSUCCESSFUL_INVALID_STATUS Make reference to Application Guidelines n. 7, n. 24, n. 29, n. 30. UNSUCCESSFUL_IN_TEST The attribute NTWCARD can not be modified if a diagnostic test is in progress on one of the NTW copies. UNSUCCESSFUL_VAR_OUT_OF_RANGE For the attributes AMONTH and ASMONTH the following relation must be satisfied: minorVal < majorVal < criticalVal. TRACE_OBJECT_UNLOCKED The imsiFileSize attribute can set only when the TRACE object is not equipped or, if equipped, in LOCKED status. INVALID_COMMAND The NTWCARD cannot be changed fromNTSWSN16/NTWSNAP to NTWSNAP_STLP or vice versa. UNSUCCESSFUL_CSCH3CSCH4_SUPPORTED The CSCH3CSCH4SUPattribute cannot be set at FALSEif at least one PTPPKF has CSCH3CSCH4SUP set at TRUE. UNSUCCESSFUL_WRONG_NTWTYPE The CSCH3CSCH4SUP attribute cannot be set at TRUE if the NTWCARD is NTWSN16. The attribute ESUP can be set at TRUE only if the attribute NTWCARD is set at NTWSNAP. The attribute NTWCARD can not be set at a value different from NTWSNAP if attribute ESUP is set at TRUE. UNSUCCESSFUL_EDGE_TRX_PRESENT The attribute ESUP can be set at FALSE only if there are no subordinated TRX objects with TRXMD set at EDGE. INCOMP_NESWLOAD_VS_MESSAGE The attribute EUSDCHO must be set at FALSE if the Software Version running on the subordinate BTSMobject belongs to BR6.0 release (see EXPSWV parameter description). UNSUCCESSFUL_SUBORDINATE_EQUIPPED 132 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The attributes NETWTYPE, NTWCARD and PCMTYPE can be set only if there are no subordinated object instances. 2. The BSC object is automatically created with default values when the BSS is powered up. 3. The BSC object cannot be deleted; the parameter values can only be changed. 4. The networktype can be set only if there are no bts equipped. 5. OVLSTTHR must be greater than OVLENTHR or equal. 6. The attribute NTWCARD can be set only if there are no LICD and LICDS equipped. 7. The attribute NTWCARD can be modied only if both the NTWcopies are in locked state. 8. Regarding the attributes AMONTH and ASMONTH, the ags minorena, majorena, criticalena and the relative thresholds attributes, note that: if the ags are set at ENABLE the threshold values cannot be skipped; if the ags are set at DISABLE the threshold values must be skipped; if the ags are skipped also the threshold values must be skipped. 9. The attribute SPENLAW can be set only if there are no instances of TRAU objects equipped on BSC. 10. The attribute PCMTYPE can be set only if there are no instances of LICDand LICDS equipped. 11. The attribute PCMTYPE can only be set at PCM24 if the attribute NETWTYPE has a value of GSMPCS, GSM850PCS or GSM850DCS. 12. When the forced handover is enabled (ENFORCHOattribute) the following attributes are relevant: 13. The timer TIMERFHO (see ADJC object) is running on the adjacent cell serving the Directed Retry signalling procedure: that is timer is dened in ADJCA-B for Directed Retry procedure fromA to B. This timer also prevents the back handovers for power budget to the origin cell A, until it expires. 14. The value NOTSTRUCT for the CICFM attribute is allowed only if the PCMTYPE is set to PCM24. 15. The attribute ENHSCSD can be set at TRUE only if EPOOL attribute is set at TRUE. 16. The attribute ENHSCSD can be set at FALSE only if HSCSDservice is not activated at BTS side , for each BTS (BTSHSCSD attribute of each BTS is set at FALSE). 17. The attribute EPOOL can only be used to change the pooling state: i.e. EPOOL can be set at TRUE only when its current value is FALSE and it can be reset to FALSE only when its current value is TRUE. In particular it is not possible to use this attribute to change the pool type of all the equipped TSLAs. 18. The pooling can be disabled only if every equipped TSLA has single-slot pool_type. 19. In order to enable the Half Rate service the HRSPEECH attribute must be set at TRUE. The NTWCARD attribute can be changed from NTWSNAP to NTWSN16 only if no PPXT and PCUTD are equipped. UNSUCCESSFUL_CODING_SCHEME_NOT_SUPPORTED Bit 25 of MNTBMASK cannot be set to 1 because some PTPPKF has been congured wih INICSCH attribute set to a value greater than CS2. fHORxLevMinOffset ADJC:FHORLMO timerFHO ADJC:TIMERFHO A30808-X3247-L230-3-7619 133 Commands Base Station Controller CML:BSC 20. The attribute ASUBENCAP can assume the TRUE and FALSE values only if NTWCARD = NTWSN16, while it can assume the NULL value only with NTWSNAP or NTWSNAP_STLP. 21. The attribute ASUBENCAP can be set at FALSE if there are no PCMS lines with WMOD attribute set at SINGLE_TRUNK. 22. The attribute SPEED145 cannot be set at FALSE if some subordinate BTS has the attribute BTSSUPP145 set at TRUE. 23. The attributes AISAT and ASUBISAT can be modied only if both the NTW copies are in locked state. 24. The following relationships must be satised between the value of the BSC7 timer and the values of the THORQST timer (HAND object) and the MSC-internal T_HO_REQ_REJ timer: T_HO_REQ_REJ (MSC) < BSCT7 < THORQST (HAND). 25. To optimize the time consumption of the BSSMAP reset procedure make sure that: BSCT16 at MSC side > BSCT13 at BSC side, and BSCT4 at BSC side > BSCT2 at MSC side. To avoid inconsistencies of the trunk status at MSC and BSC side please make sure that T16 at MSC side does not expire before the blocking procedure at the A-inter- face (initiated by BSC) has been completed. In case of BSCT16 expiry MSCrepeats the reset message and all information about previously blocked circuits at the BSC is lost at msc side. The time consumption of the blocking procedure depends on the amount of PCM lines connecting BSC and MSC. Recommended value for BSCT16: 35s. 26. For supervision of receipt of assignment complete or handover complete the SBS only uses timer BSCT10 resp. BSCT8 (GSM Rec. 08.08). Within GSM Rec. 04.08 timer T3107 is specied for supervision of receipt of handover complete resp. assignment complete. In addition two timers with the same task are specied for BSSMAP, namely BSCT8 and BSCT10. To easier the handling of these timers only two of them are used within SBS. There is no lack in supervision of above named messages due to this implementation, neither for internal nor for external handover procedures. 27. If EPRE parameter (see BTS object) is set at TRUE value, the timer BSCT7 must be set at a value between 6 and 254. 28. The attributes TRACEMG and TRACEMR can be modied only if the TRACE and the CTRCO objects are in "Locked" state. 29. All AMR TRAUs and all S2 and S3 TRAUs must be in LOCKED state in order to set EPOOL at FALSE. 30. The value of the attribute ASUBENCAP can be changed only if there are no PCMGs equipped. 31. The NTWCARD attribute can be changed (from NTWSNAP to NTWSN16 and vice- versa) only when no LICDs, PPLDs or PCUs are equipped. 32. The attribute ASUBENCAP cannot be set at FALSE, if NTWCARD = NTWSNAP or NTWCARD = NTWSNAP_STLP. 33. The default value of the attribute NTWCARD is NTWSN16. 34. In case of cells congured as Extended or Concentric (see BTS object) it is recommended to set CPOLICY parameter at NO_PREFERENCE value, in order to avoid that a call setup, requested in Near/Inner area, is established in Far/Complete area to satisfy the CPOLICY setting and later on moved into Near/Inner area upon BTS request. 35. The attribute NCRESELFLAG cannot be set to DISABLE if the attribute TRFPS is TRUE; 134 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 36. The attribute TRFPS cannot be set to TRUE if the attribute NCRESELFLAG is set to DISABLE. 37. The attribute ENHSCSD can be set to FALSE only if HSCSDservice is not activated at BTSTD side, for each BTSTD (BTSHSCSD attribute of each BTSTD is set to FALSE). 38. The MSCVER attribute can be set to PHASE1, PHASE2 or PHASE2CC only if no BTSTD is equipped. 39. Regarding the MNTBMASK parameter, the following considerations can be done: every command SET BSC:MNTBMASK=BITx resets the maintenance bit mask to its default value und just changes that bit which is included in the command. In other words, if BITy was set before, the command SET BSC:MNTBMASK=BITx; resets BITy to '0' and sets BITx to '1'. This means that, if some of the bits are already set, and another one is to be set in addition, it is required to re-enter the command with ALL required bits set; all bits can be reset to their original values using the setting MNTB- MASK=<NULL> or MNTBMASK=<DEFAULT>; to set several bits at the same time, they must be linked with a 'pipe' (Example: MNTBMASK=BIT8|BIT9). Example of Command Execution Set BSC:NAME=BSC:0,NETWTYPE=GSMDCS,T3122=10, ERRACT=CRITICAL-MAJOR-MAJOR-MINOR-WARNING, ENCALSUP=NOENCR&GSMV1,MAXNCELL=1,MSCV=PHASE1,OVLSTTHR=7000, OVLENTHR=7000,BSCOVLH=FALSE,BTSOVLH=FALSE,MSCOVLH=FALSE, EISDCCHHO=ENABLE,ENFORCHO=ENABLE,NTWCARD=NTWSN16, AMONTH=ENABLE-35-ENABLE-65-ENABLE-95, ASMONTH=ENABLE35ENABLE65ENABLE95, SPENLAW=A_LAW,PCMTYPE=PCM30,EFRSUPP=FALSE,CICFM=GSM, EPOOL=TRUE,MSCPOOL=TRUE,HRSPEECH=TRUE,SPEED145=TRUE,ENHSCS D=TRUE,ENFOIAHO=TRUE, HOSYNC=NONSYNC, ASUBENCAP=FALSE,ASUBISAT=FALSE,AISAT=FALSE, MAFIRACHO=3, MADGRLV=2,NOTFACCH=ALWAYS,DLAPDOVL=TRUE,MEDAFUST=1-30, MEDAFUPE=UPPE_0H,MASCLOGFS=4, IMSIFSIZ=15, CFS=3,ALRM- SEVBTS=MAJOR,ALRMSEVTRX=CRITICAL, BSCT1=SEC5-10,BSCT3=SEC5-30,BSCT4=HALFSEC-18,BSCT7=SEC5-31, BSCT8=HALFSEC-25,BSCT10=SEC5-30,BSCT11=HLFSEC-38, BSCT13=HALFSEC-50,BSCT17=SEC5-70,BSCT18=SEC5-40,BSCT19=SEC5-60, BSCT20=SEC5-12,BSCTQHO=SEC5-80, BSCT3121=HLFSEC- 10,TCBSCI=100,TRACEMR=TRUE,TRACEMG=5,TRFCT=30,EPA=TRUE, CBCPH=PH1_CBC,TGUARDTCHSD=SEC0,CPOLICY=DATA_CALL_ON_BCCH, DGRSTRGY=HSCSD_FIRST_DOWNGRADE,CITASUP=TRUE,LCSNSSC=TRUE, LCSMONTH=1-1-1,SIMSCREL99=FALSE, TRFPS= FALSE, NCRESELFLAG=DISABLE, CSCH3CSCH4SUP=FALSE,UPGRFREQ=SEC2- SEC2,ACCEPTGDEGR=PER20,EUSDCHO=FALSE,ALRMSEVIPLI=MAJOR, ESUP=TRUE,SISGSNREL99=TRUE,NECI=TRUE, ASCIONECHMDL=TRUE, EHRACTAMR=TRUE; The following is an example of the command necessary to configure a network having an MSC not supporting new A-Interface IES (Current Channel, Speech Version used and chosen), as in Latin America. A30808-X3247-L230-3-7619 135 Commands Base Station Controller CML:BSC Set BSC:NAME=BSC:0, NETWTYPE=GSMPCS,..., MAXNCELL=maxNCell,MSCV=PHASE2; while the following is an example of the set of commands necessary to configure a network having an MSC supporting new A-Interface IES (as in USA): Set BSC:NAME=BSC:0,NETWTYPE=GSMPCS,..., MAXNCELL=maxNCell,MSCV=PHASE2CCEFR; 136 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BSCE The BSCE object represents the BSC equipment. GET BSCE Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE GET BSCE Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of the parameters, selected by the operator, of the BSCE object related to: alarm severity of the associated BSCE hardware objects; remote inventory (SALUNAME and EQUPOS). The validity range of the object address "bscen" can be found in Appendix A. System Responses: GET BSCE: NAME=BSCE:bscen [,REQATTL=ALRMSEVDISK, ALRMSEVDK40, ALRMSEVEPWR, ALRMSEVIXLT, ALRMSEVLICD, ALRMSEVLICDS, ALRMSEVMEMT, ALRMSEVMPCC, ALRMSEVNTW, ALRMSEVPPCC, ALRMSEVPPLD, ALRMSEVPWRD, ALRMSEVSYNC, ALRMSEVSYNE, ALRMSEVTDPC, ALRMSEVX25A, ALRMSEVX25D, ALRMSEVPPCU, ALRMSEVPPXL, ALRMSEVPPXU, ALRMSEVPPXP, ALRMSEVPPXT, ALRMSEVCPEX, ALRMSEVFAN, SALUNAME, EQUPOS]; GET ACK: NAME name ALRMSEVDISK: alarmSeverityDisk ALRMSEVDK40: alarmSeverityDk40 ALRMSEVEPWR: alarmSeverityEpwr ALRMSEVIXLT: alarmSeverityIxlt ALRMSEVLICD: alarmSeverityLicd ALRMSEVLICDS: alarmSeverityLicds ALRMSEVMEMT: alarmSeverityMemt ALRMSEVMPCC: alarmSeverityMpcc ALRMSEVNTW: alarmSeverityNtw ALRMSEVPPCC: alarmSeverityPpcc ALRMSEVPPLD: alarmSeverityPpld ALRMSEVPWRD: alarmSeverityPwrd ALRMSEVSYNC: alarmSeveritySync A30808-X3247-L230-3-7619 137 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get BSCE:NAME=BSCE:0,REQATTL=ALRMSEVDISK&ALRMSEVDK40& ALRMSEVEPWR&ALRMSEVIXLT&ALRMSEVLICD&ALRMSEVLICDS& ALRMSEVMEMT&ALRMSEVMPCC&ALRMSEVNTW&ALRMSEVPPCC& ALRMSEVPPLD&ALRMSEVPWRD&ALRMSEVSYNC&ALRMSEVSYNE& ALRMSEVTDPC&ALRMSEVX25A&ALRMSEVX25D&ALRMSEVPPCU& ALRMSEVPPXL&ALRMSEVPPXU&ALRMSEVPPXP&ALRMSEVPPXT&ALRM- SEVCPEX&ALRMSEVFAN& SALUNAME&EQUPOS; GET BSCE ALARMSEV Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSCE GET BSCE ALARMSEV Applicability: Phase 2. Visibility level 1. ALRMSEVSYNE: alarmSeveritySyne ALRMSEVTDPC: alarmSeverityTdpc ALRMSEVX25A: alarmSeverityX25a ALRMSEVX25D: alarmSeverityX25d ALRMSEVPPCU: alarmSeverityPpcu ALRMSEVPPXL: alarmSeverityPpxl ALRMSEVPPXU: alarmSeverityPpxu ALRMSEVPPXP: alarmSeverityPpxp ALRMSEVPPXT: alarmSeverityPpxt ALRMSEVCPEX: alarmSeverityCPEX ALRMSEVFAN: alarmSeverityFAN SALUNAME: salesUniqueName EQUPOS: equipmentPosition GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already created. UNSUCCESSFUL_FILE_SYSTEM_ERROR A file system error occurs during the DK40 access. FILE_CORRUPTED The file on DK40 is corrupted: delete it. GET BSCE ALARMSEV: NAME=BSCE:bscen; 138 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command is used to retrieve the values of all the parameters of the SEVERITY group. The validity range of the object address "bscen" can be found in Appendix A. System Responses: Application Guidelines: None. GET BSCE ALARMSEV ACK: NAME name ALRMSEVDISK: alarmSeverityDisk ALRMSEVDK40: alarmSeverityDk40 ALRMSEVEPWR: alarmSeverityEpwr ALRMSEVIXLT: alarmSeverityIxlt ALRMSEVLICD: alarmSeverityLicd ALRMSEVLICDS: alarmSeverityLicds ALRMSEVMEMT: alarmSeverityMemt ALRMSEVMPCC: alarmSeverityMpcc ALRMSEVNTW: alarmSeverityNtw ALRMSEVPPCC: alarmSeverityPpcc ALRMSEVPPLD: alarmSeverityPpld ALRMSEVPWRD: alarmSeverityPwrd ALRMSEVSYNC: alarmSeveritySync ALRMSEVSYNE: alarmSeveritySyne ALRMSEVTDPC: alarmSeverityTdpc ALRMSEVX25A: alarmSeverityX25a ALRMSEVX25D: alarmSeverityX25d ALRMSEVPPCU: alarmSeverityPpcu ALRMSEVPPXL: alarmSeverityPpxl ALRMSEVPPXU: alarmSeverityPpxu ALRMSEVPPXP: alarmSeverityPpxp ALRMSEVPPXT: alarmSeverityPpxt ALRMSEVCPEX: alarmSeverityCPEX ALRMSEVFAN: alarmSeverityFAN SALUNAME: salesUniqueName EQUPOS: equipmentPosition GET BSCE ALARMSEV NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already created. UNSUCCESSFUL_FILE_SYSTEM_ERROR A file system error occurs during the DK40 access. FILE_CORRUPTED The file on DK40 is corrupted: delete it. A30808-X3247-L230-3-7619 139 Commands Base Station Controller CML:BSC Example of Command Execution Get BSCE ALARMSEV:NAME=BSCE:0; 140 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET BSCE REMINV Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCEGET BSCE REMINV Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the REMINV group. The validity range of the object address "bscen" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get BSCE REMINV:NAME=BSCE:0; GET BSCE REMINV: NAME=BSCE:bscen; GET ACK: NAME name SALUNAME salesUniqueName EQUPOS equipmentPosition GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already created. UNSUCCESSFUL_FILE_SYSTEM_ERROR A file system error occurs during the DK40 access. FILE_CORRUPTED The file on DK40 is corrupted: delete it. A30808-X3247-L230-3-7619 141 Commands Base Station Controller CML:BSC GETACTIVEALARMS BSCE Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE GETACTIVEALARMS BSCE Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the list of the active alarms, selected by means of the event type parameters. The validity range of the object address "bscen" can be found in Appendix A. System Responses: Application Guidelines: 1. Hardware objects which are in disabled-not-inizialized state (e.g. during cross copy) are not reported in the active alarm list. 2. The active alarm list of the TRAU retrieved from LMT-BSC (GETACTIVEALARMS TRAUE) and/or by RC will contain only the equipment managed objects (BSMS, TPWR, TRAC) whereas when it is retrieved directly from LMT-TRAU it will contain also the functional managed objects (PCMS, PCMT, TRANSCODER). Example of Command Execution Getactivealarms BSCE:NAME=BSCE:0, EVTYP=COMMUNICATION_ FAILURE_EVENT; PERFTEST BSCE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC PERFTEST BSCE Applicability: Phase 2. Visibility level 1. GETACTIVEALARMS BSCE: NAME=BSCE:bscen [,EVTYP=]; GETACTIVEALARMS BSCE ACK: The output of the command can be composed by one or more pack- ages with a maximum number of three mnemonics of objects enqueued in the specified alarm event list; at the end a message is displayed notifying the end of the alarm event list. PERFTEST BSCE: NAME=BSCE:bscen,MORT=; 142 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command is used to start an asynchronous test in the BSC system; different categories of test can be addressed. The operator can request to performseveral diagnostics on different hardware units and the diagnostic must be able to manage all the requests. The maximum number of diagnostics that can run in parallel are 8, moreover they can be executed only if compatible with the ones in progress. If the requested diagnostic is incompatible or 8 different diagnostics are already running, a queuing procedure is implemented and it will be executed when possible. Otherwise it is activated at once. The incompatible diagnosis are indicated in the following table. The validity range of the object address "bscen" can be found in Appendix A. System Responses: Object Incompatible with MPCC MPCC TDPC MEMT DK40 DK40 - - TDPC TDPC MPCC MEMT MEMT MEMT MPCC TDPC NTW NTW PPCC PPLD IXLT IXLT - - PPCC PPCC PPLD NTW PPLD PPLD PPCC NTW LICD LICD - - LICDS LICDS - - PWRD PWRD EPWR - EPWR EPWR PWRD - PPCU PPCU PPCC PPLD DISK DISK MPCC - PPXU PPXL - - PPXL PPXU - - Tab. 2.1 Incompatible test object PERFTEST BSCE ACK: PERFTEST BSCE:NAME=BSCE:0, MORT=PPLD:4 testObject=BSCETEST:<n> The test results will be displayed at the end of the test phases. Result TEST: name = BSCETEST:<n> testOutcome = This field represents the test result; one of the following values can be displayed: A30808-X3247-L230-3-7619 143 Commands Base Station Controller CML:BSC Application Guidelines: 1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked" state, if the diagnostic is intrusive; for the EPWR and PWRD objects the administra- tive state can be Unlocked (diagnostic not intrusive). 2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for test" state. When the test result is: "fail" the object goes in Disabled / Failed operational state; "pass" the object goes in Enabled operational state; Pass all the test phases are successfully performed. Inconclusive the test is aborted by the system or the test is terminated by the operator. Fail if at least one of the executed phases fail. mOts = It is the identifier of the hardware object under test. testTermination = It specifies how the test is terminated, it can assume the following values: Normal all the test phases are performed. Abort the test is aborted by system. Cancel the test is terminated by operator. executedPhases phaseId = It represents the list of the executed test phases (in case of successful test result, all the test phases will be listed). additionalWords = .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases; they are displayed only for test stopped during it execution. phaseId = .... poprosedRepair Action = A list of most probable fail probable causes is shown (max four messages) PERFTEST BSCE NACK: NACK CAUSES: MOTS_NOT_LOCKED The selected object is not in "Locked" administrative state. OTHER_TESTS_RUNNING Other incompatible tests are already running or no more parallel execution of tests possible. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. 144 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller "inconclusive" the object returns to the operational state previous to the test or in Enabled operational state. 3. If a test request for a PPXX (PPCU, PPLD, PPCC, PPXL or PPXU) object fails because an other load is in progress, the object is not reloaded automatically; the command must be repeated in order to reload the card. Example of Command Execution Perftest BSCE:NAME=BSCE:0,MORT=PPLD:0; A30808-X3247-L230-3-7619 145 Commands Base Station Controller CML:BSC SET BSCE Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE SET BSCE Applicability: Phase 2. Visibility level 2. Command Description: This command allows to set the following BSCE parameters: the alarms severity associated to hardware objects; the attributes needed to control the data related to BSCE remote inventory. These remote inventory information are not saved into DBA file but saved into BSCDATA.RI file in REM_INV_DIR directory. When the file is not present the attributes assume their default values. The validity range of the object address "bscen" can be found in Appendix A. System Responses: Application Guidelines: None. SET BSCE: NAME=BSCE:bscen [,ALRMSEVDISK=] [,ALRMSEVDK40=] [,ALRMSEVEPWR=] [,ALRMSEVIXLT=] [,ALRMSEVLICD=] [,ALRMSEVLICDS=] [,ALRMSEVMEMT=] [,ALRMSEVMPCC=] [,ALRMSEVNTW=] [,ALRMSEVPPCC=] [,ALRMSEVPPLD=] [,ALRMSEVPWRD=] [,ALRMSEVSYNC=] [,ALRMSEVSYNE=] [,ALRMSEVTDPC=] [,ALRMSEVX25A=] [,ALRMSEVX25D=] [,ALRMSEVPPCU=] [,ALRMSEVPPXL=] [,ALRMSEVPPXU=] [,ALRMSEVPPXP=] [,ALRMSEVPPXT=] [,ALRMSEVCPEX=] [,ALRMSEVFAN=] [,SALUNAME=] [,EQUPOS=]; SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_FILE_SYSTEM_ERROR A file system error occurs during the DK40 access. UNSUCCESSFUL_INVALID_ATTRIBUTES The salesUniqueName parameter must be 11 characters long and the equipmentPosition parameter must be 6 characters long. 146 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Set BSCE:NAME=BSCE:0,ALRMSEVLICD=CRITICAL, ALRMSEVX25A=MINOR,SALUNAME="AD042S7449F",EQUPOS="010101"; STOPTEST BSCE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSCE STOPTEST BSCE Applicability: Phase 2. Visibility level 1. Command Description: This command allows to terminate the test previously requested; the test can be in progress or in the waiting list (queued). In the first case the process that executes the diagnostic will be interrupted by executing the end phase; in the second case the test will be removed from the waiting list. The validity range of the object address "diskn" can be found in Appendix A. System Responses: STOPTEST BSCE: NAME=BSCE:bscen [,MORT=] ,TO=; STOPTEST DISK ACK: STOPTEST DISK:NAME=DISK:0; testObject=BSCETEST:<n> Result BSCETEST: name = BSCETEST:<n> testOutcome = inconclusive mOts = DISK:0 testTermination = Cancel executedPhases phaseId = It represents the list of the executed test phases; the list is not shown for test in the waiting list (queued). .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases; the list is not shown for test in the waiting list (queued). phaseId = .... STOPTEST DISK NACK: NACK CAUSES: NO_SUCH_TEST A30808-X3247-L230-3-7619 147 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Stoptest BSCE:NAME=BSCE:0,MORT=PPLD:0,TO=BSCETEST:5; The test is not active. UNABLE_TO_STOP_TEST The test can not be stopped. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. 148 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BSCESUDB The BSCESUDB (BSC Executable Software Unit DB) object represents a logical container roughly corresponding to a directory containing Data Base files, identified by Data Base Replaceable Software Units. The addressing scheme is applicable (20 instances for this object are allowed); the object is automatically created at the corresponding RSUDB (Replaceable Software Unit Data Base) creation, only attribute values can be changed. All related commands consist of two fields but only one can be used (NAME or USER LABEL DB). GET BSCESUDB Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCESUDB GET BSCESUDB Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of the parameters selected by the operator by means of the REQATTL correspondent list. The validity range of the object address bscesudbn can be found in Appendix A. System Responses: GET BSCESUDB: IDBSCESUDB= [,REQATTL=ULAB, RELRSU, DBVER]; GET ACK: ULAB: userLabel RELRSU: relatedRSU DBVER: dbVersion GET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK The command is rejected due to an internal subsystem abort. A30808-X3247-L230-3-7619 149 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get BSCESUDB:NAME=BSCESUDB:0,REQATTL=ULAB&RELRSU&DBVER; Get BSCESUDB:IDBSCESUDB="userLabel", REQATTL=ULAB&RELRSU&DBVER; GET BSCESUDB BASICS Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCESUDB GET BSCESUDB BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address bscesudbn can be found in Appendix A. System Responses: Application Guidelines: None. GET BSCESUDB BASICS: IDBSCESUDB=; GET ACK: ULAB: userLabel RELRSU: relatedRSU DBVER: dbVersion GET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK An internal system abort has occured. 150 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Get BSCESUDB BASICS:NAME=BSCESUDB:0; Get BSCESUDB BASICS:IDBSCESUDB="userLabel"; GET BSCESUDB STAT Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCESUDB GET BSCESUDB STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the BSCESUDB object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address bscesudbn can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get BSCESUDB STAT:NAME=BSCESUDB:0; Get BSCESUDB STAT:IDBSCESUDB="userLabel"; GET BSCESUDB STAT: IDBSCESUDB=; GET BSCESUDB STAT ACK: GET BSCESUDB STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_SM_TOO_BUSY The message occurs when the Status Handler task is performing the maximum number of commands. A30808-X3247-L230-3-7619 151 Commands Base Station Controller CML:BSC GETINFO BSCESUDB Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCESUDB GETINFO BSCESUDB Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information about a single DB instance: 1. For the RSUDB object related to the BSCESUDB: RSUDB instance identier, User label, Version, Related les, Operational state; 2. Information about the role of the BSCESUDB in the BSCOSUDB. The validity range of the object address bscesudbn can be found in Appendix A. System Responses: GETINFO BSCESUDB ACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** INFORMATION *** GETINFO REPORT BSCESUDB: NAME = BSCESUDB:1 RUNNING ESUDB INSTANCE: 0 USER LABEL: EFESTOBR61_OLD_09 VERSION: SBS-M-262-1-09-01 17:18:27 01/01/1995 RELATED FILES: DBFILE_OLD.DBA OPERATIONAL STATE: ENABLED USED AS: RUNNINGESU END OF REPORT NOTE: the DB VERSION may be unavailable; in this case the default value to display is ... ... VERSION: NOT_AVAILABLE 00:00:00 01/01/1970 GETINFO BSCESUDB NACK: GETINFO BSCESUDB: IDBSCESUDB=; 152 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack BSCESUDB: name = BSCESUDB:1 nackCause = <nack cause> Application Guidelines: The attribute relatedFiles displays only the file name without the complete BSC disk storage path. Example of Command Execution Getinfo BSCESUDB:NAME=BSCESUDB:0; Getinfo BSCESUDB:IDBSCESUDB="userLabel"; NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. A30808-X3247-L230-3-7619 153 Commands Base Station Controller CML:BSC BSCESUSW The BSCESUSW (BSC Executable Software Unit SW) object represents a logical container corresponding to a directory containing the software load header files, identified by Software Load Header Replaceable Software Units. The addressing scheme is applicable (20 instances for this object is allowed); the object is automatically created at the corresponding RSUSWLH (Raplaceable Software Unit SW Load Header) creation, only attribute values can be changed. All related commands consist of two fields but only one can be used (NAME or USER LABEL SWLH). GET BSCESUSW Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCESUSW GET BSCESUSW Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of the parameters selected by the operator by means of the REQATTL correspondent list. The validity range of the object address bscesuswn can be found in Appendix A. System Responses: GET BSCESUSW IDBSCESUSW= [,REQATTL= ULAB, VER, RELRSU]; GET ACK: ULAB: userLabel VER: version RELRSU: relatedRSU GET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK An internal system abort has occurred. 154 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get BSCESUSW:NAME=BSCESUSW:0,REQATTL=ULAB&VER&RELRSU; Get BSCESUSW:IDBSCESUSW="userLabel",REQATTL=ULAB&VER&RELRSU; GET BSCESUSW BASICS Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCESUSW GET BSCESUSW BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address bscesuswn can be found in Appendix A. System Responses: Application Guidelines: None. GET BSCESUSWBASICS IDBSCESUSW=; GET ACK: ULAB: userLabel VER: version RELRSU: relatedRSU GET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK An internal system abort has occurred. A30808-X3247-L230-3-7619 155 Commands Base Station Controller CML:BSC Example of Command Execution Get BSCESUSW BASICS:NAME=BSCESUSW:0; Get BSCESUSW BASICS:IDBSCESUSW="userLabel"; GET BSCESUSW STAT Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCESUSW GET BSCESUSW STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the BSCESUSW object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address bscesuswn can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get BSCESUSW STAT:NAME=BSCESUSW:0; Get BSCESUSW STAT:IDBSCESUSW="userLabel"; GET BSCESUSW STAT: IDBSCESUSW=; GET BSCESUSW STAT ACK: GET BSCESUSW STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_SM_TOO_BUSY The message occurs when the Status Handler task is performing the maximum number of commands. 156 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETINFO BSCESUSW Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCESUSW GETINFO BSCESUSW Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information about a SW version: 1. Information about the RSUSWLH object related to the BSCESUSW: RSUSWLH Instance identier, User label associated, Version number, Related les, Operational state; 2. For each executable le RSUEXE present in the SW load header: RSUEXE instance identier, Processor type, Version number, Related les, Operational state; 3. For each patch le RSUPCH present (if any): RSUPCH instance identier, Processor type, User label associated, Permanent attribute, Related les, Operational state, Availability status; 4. Information about the use of the BSCESUSW (i.e. running, backup, etc.). The validity range of the object address bscesuswn can be found in Appendix A. System Responses: GETINFO BSCESUSW ACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** INFORMATION *** GETINFO REPORT: NAME = BSCESUSW:1 GETINFO BSCESUSW IDBSCESUSW=; i If the LMT is connected in remote mode, it is not possible to execute this command. A30808-X3247-L230-3-7619 157 Commands Base Station Controller CML:BSC SBS RSUSWLH INSTANCE: 0 USER LABEL: 02-06-01-01-00-40_01-08-31 VERSION: 02-06-01-01-00-40_01-08-31 RELATED FILES: HB010400.SWL OPERATIONAL STATE: ENABLED SBS RSUEXE INSTANCE: 0-1 SBS PROCTYPE: TDPC VERSION: 02-06-01-01-21-00_01-08-31 RELATED FILES: T12100.ABS OPERATIONAL STATE: ENABLED SBS RSUEXE INSTANCE: 0-2 SBS PROCTYPE: PPCU VERSION: 02-06-01-01-00-21_01-08-31 RELATED FILES: W10021.ABS OPERATIONAL STATE: ENABLED ... ... SBS RSUEXE INSTANCE: 0-7 SBS PROCTYPE: IXLT VERSION: 02-06-01-01-21-00_01-08-31 RELATED FILES: X12100.ABS OPERATIONAL STATE: ENABLED SBS RSUPCH INSTANCE: 0-3-0 SBS PROCTYPE: MPCC USER LABEL: MEB00 SBS PERMANENT: TRUE RELATED FILES: M2610000.PCH OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: OFF_DUTY SBS RSUPCH INSTANCE: 0-1-1 SBS PROCTYPE: TDPC USER LABEL: TEB00 SBS PERMANENT: TRUE 158 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller RELATED FILES: T2610000.PCH OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: OFF_DUTY ... ... SBS RSUPCH INSTANCE: 0-3-1 SBS PROCTYPE: MPCC USER LABEL: MEB16 SBS PERMANENT: TRUE RELATED FILES: M2610001.PCH OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: OFF_DUTY USED AS: NOT USED END OF REPORT GETINFO BSCESUSW NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack BSCESUSW: name = BSCESUSW:1 nackCause = <nack cause> Application Guidelines: 1. The attribute relatedFiles displays only the le name without the complete BSC disk storage path. 2. For each RSUPCH with PCH extension the related RSUPCH with BAK extension (if any) is showed immediately after. GETINFO NACK: NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. A30808-X3247-L230-3-7619 159 Commands Base Station Controller CML:BSC Example of Command Execution Getinfo BSCESUSW:NAME=BSCESUSW:0; Getinfo BSCESUSW:IDBSCESUSW="userLabel"; 160 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BSCETEST The BSCETEST locates a test object in the BSS system; this object is created when an activation of a diagnostic occurs. GET BSCETEST Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCETEST GET BSCETEST Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the attributes belonging to a specified test object; the test object is created by the system as a result of a request to start an asynchronous test and is deleted when the test terminates. The validity range of the object address "bscetestn" can be found in Appendix A. System Responses: GET BSCETEST: NAME=BSCETEST:bscetestn [,MORT=]; GET BSCETEST ACK: GET BSCETEST:NAME=BSCETEST:<n>; name = BSCETEST:<n> mOts = EPWR:0 bscetestState = It can assume one of the following values: not_initialized, idle, initializing, suspended, testing, terminating and disabled. bscetestOutcome = It represents the test result: it can be Inconclusive (meaning-less: that is if the phases already executed were successful) or Fail (if at least one of the executed phases failed). bscetestMonitor phaseId = It is a list of the phases to execute and their status that can be: pass, fail, running or waiting. phaseStatus = phaseId = phaseStatus = .... GET BSCETEST EPWR NACK: NACK CAUSES: A30808-X3247-L230-3-7619 161 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get BSCETEST:NAME=BSCETEST:0,MOT=DK40:0; NO_SUCH_TEST The test is not active. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. 162 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BSCOSUDB The BSCOSUDB (BSCOperational Software Unit DB) object is related to the Data Base present on the BSC disk. Its attributes respectively identify the running, backup, new and fallback Data Base. The addressing scheme is not applicable (only 1 instance for this object is allowed); the object is automatically created and only the attribute values can be changed. GET BSCOSUDB Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUDB GET BSCOSUDB Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of the parameters selected by the operator by means of the REQATTL correspondent list. The validity range of the object address bscosudbn can be found in Appendix A. System Responses: GET BSCOSUDB NAME=BSCOSUDB:bscosudbn [,REQATTL=RUNESU, BCKUPESU, NEWESU, FALLBESU]; GET ACK: RUNESU: runningESU BCKUPESU: backupESU NEWESU: newESU FALLBESU: fallbackESU GET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK An internal subsystem abort has occurred. A30808-X3247-L230-3-7619 163 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get BSCOSUDB:NAME=BSCOSUDB:0,REQATTL=RUNESU&BCKUPESU& NEWESU&FALLBESU; GET BSCOSUDB BASICS Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUDB GET BSCOSUDB BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address bscosudbn can be found in Appendix A. System Responses: Application Guidelines: None. GET BSCOSUDB BASICS NAME=BSCOSUDB:bscosudbn; GET ACK: RUNESU: runningESU BCKUPESU: backupESU NEWESU: newESU FALLBESU: fallbackESU GET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK An internal system abort has occurred. 164 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Get BSCOSUDB BASICS:NAME=BSCOSUDB:0; GETINFO BSCOSUDB Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUDB GETINFO BSCOSUDB Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information related to the BSCESUDB set as runningESU, backupESU, newESU and fallbackESU: 1. For each running ESU present in the system: BSCESUDB instance identier, User label associated, Version number, Operational state; 2. For each backup ESU present in the system: BSCESUDB instance identier, User label associated, Version number, Operational state; 3. For each new ESU present in the system: BSCESUDB instance identier, User label associated, Version number, Operational state; 4. For each fallback ESU present in the system: BSCESUDB instance identier, User label associated, Version number, Operational state. The validity range of the object address bscosudbn can be found in Appendix A. System Responses: GETINFO BSCOSUDB ACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** INFORMATION *** GETINFO REPORT BSCOSUDB: GETINFO BSCOSUDB NAME=BSCOSUDB:bscosudbn; A30808-X3247-L230-3-7619 165 Commands Base Station Controller CML:BSC NAME = BSCOSUDB:1 RUNNING ESUDB INSTANCE: 0 USER LABEL: EFESTOBR61_OLD_09 VERSION: SBS-M-262-1-09-01 17:18:27 01/01/1995 OPERATIONAL STATE: ENABLED BACKUP ESUDB INSTANCE: 0 USER LABEL: EFESTOBR61_OLD_09 VERSION: SBS-M-262-1-09-01 17:18:27 01/01/1995 OPERATIONAL STATE: ENABLED FALLBACK ESUDB INSTANCE: 0 USER LABEL: EFESTOBR61_OLD_09 VERSION: SBS-M-262-1-09-01 17:18:27 01/01/1995 OPERATIONAL STATE: ENABLED NEW ESUDB INSTANCE: 0 USER LABEL: EFESTOBR61_OLD_09 VERSION: SBS-M-262-1-09-01 17:18:27 01/01/1995 OPERATIONAL STATE: ENABLED END OF REPORT NOTE: the VERSION fields in ESU descriptions may be unavailable; in this case the default value to display is the following ... ... VERSION: NOT_AVAILABLE 00:00:00 01/01/1970 GETINFO BSCOSUDB NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack BSCOSUDB: name = BSCOSUDB:1 nackCause = <nack cause> Application Guidelines: None. NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. 166 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Getinfo BSCOSUDB:NAME=BSCOSUDB:1; A30808-X3247-L230-3-7619 167 Commands Base Station Controller CML:BSC SAVEDB BSCOSUDB Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUDB SAVEDB BSCOSUDB Applicability: Phase 2. Visibility level 2. Command Description: This command triggers save BSC Data Base operational sequence. The validity range of the object address bscosudbn can be found in Appendix A. System Responses: Application Guidelines: The system must be in normal exercise (no other operation is in progress). Example of Command Execution Savedb BSCOSUDB:NAME=BSCOSUDB:0; SET BSCOSUDB Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUDB SET BSCOSUDB Applicability: Phase 2. Visibility level 2. SAVEDB BSCOSUDB NAME=BSCOSUDB:bscosudbn; SAVEDB ACK: SAVEDB NACK: NACK CAUSES: CMND_REJECTED_DUE_OTHER_CMND_IN_PROGRESS The system is not in normal exercise (another command is in progress). SET BSCOSUDB NAME=BSCOSUDB:bscosudbn, IDBSCESUDB=, ACTN=; 168 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command performs an assignment of a Database instance to one of the following attributes: backupESU OSUDB attribute (BCKUPESU), i.e. the selected software load becomes the backup software load, or fallbackESUOSUDBattribute (FALLBESU), i.e. the selected software load becomes the fallback software load, or newESU OSUDB attribute (NEWESU), i.e. the selected software load becomes the new software load. When runningESU OSUDB attribute (RUNESU) is selected, this command performs a Load Database from newESU OSUDB attribute when the object address bscosudbn corresponds to the object address contained into newESU OSUDB attribute only. Note that the above-mentioned object address is different from the address of the BSCOSUDB object, which can assume the 0 value only (see below). In the other cases a Nack to this command is given. That is: the command: SET BSCOSUDB NAME=bscosudbn ACTN=RUNNING_ESU (where bscosudbn is the object address contained into newESU) corresponds to the command: SETRUNNEWBSCOSUDB (see the related command description and nack causes) The validity range of the object address bscosudbn can be found in Appendix A. This command consists of two fields but only one can be used (NAME or USER LABEL DB). System Responses: Application Guidelines: 1. The system must be in normal exercise (no other operation is in progress). 2. The OperationalState attribute of the MEID passed by the command must be ENABLED. 3. The Data Base version has to be compatible with the software to load. 4. The OperationalState of the BSCOSUDB newESU attribute must be ENABLED. 5. If the backupESU software is not NULL, the generic Data Base instance entered must be compatible with it. SET ACK: SET NACK: NACK CAUSES: CMD_NOT_ALLOWED_IN_CURRENT_PHASE The system is not in normal exercise. RELATED_OBJECTS_DISABLED The ESUDB MEID object passed by the command is DISABLED. INCOMPATIBLE_DBA_VERSION The Data Base is not compatible with the corresponding backupESU SW (or newESU SW, or fallbackESU SW). NO_ADMITTED_OPERATION The MEID object passed is not a valid one for the specific command. A30808-X3247-L230-3-7619 169 Commands Base Station Controller CML:BSC Example of Command Execution Set BSCOSUDB:NAME=BSCOSUDB:0, IDBSCESUDB=BSCESUDB:0,ACTN=FALLBACK_ESU; Set BSCOSUDB:NAME=BSCOSUDB:0, IDBSCESUDB="userLabel",ACTN=FALLBACK_ESU; SETRUNNEW BSCOSUDB Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUDB SETRUNNEW BSCOSUDB Applicability: Phase 2. Visibility level 2. Command Description: This command loads the Data Base marked as new, i.e. the Data Base that was marked as new becomes the running one. The validity range of the object address bscosudbn can be found in Appendix A. System Responses: SETRUNNEW BSCOSUDB NAME=BSCOSUDB:bscosudbn; SETRUNNEW ACK: SETRUNNEW NACK: NACK CAUSES: CMD_NOT_ALLOWED_IN_CURRENT_PHASE The system is not in normal exercise. NO_ADMITTED_OPERATION The MEID object passed is not a valid one for the specific command. The backupESU SW is null. The backupESU DB is null. The runningESU and backupESU of BSCOSUDB are not equal. An ESU can be set as running only if it is already the newESU. The specific ESU DB is not compatible with the rack type. The specified BSCESUDB is not compatible with the NTW type indi- cated in NTWCARD parameter of BSC object. For further details see Application Guideline n. 4. RELATED_OBJECTS_DISABLED The ESUDB MEID object passed by the command is DISABLED. The ESUDB MEID object contained in backupESU is DISABLED. INCOMPATIBLE_DBA_VERSION The Data Base is not compatible with the corresponding newESU SW. 170 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The system must be in normal exercise (no other operation is in progress). 2. The OperationalState of the BSCOSUDB newESU attribute must be ENABLED. 3. The Database version has to be compatible with the software to load. 4. In the above mentioned case the system automatically reloads the Data Base marked as backup; if also this operation fails the system automatically performs a Bring Up. If the systemdoes not manage to load the Data Base marked as backup, it loads the Data Base with default values. Since default value of NTWCARD parameter is NTWSN16, before loading a Data Base with NTWCARD = NTWSNAP the operator has to perform one of the two following actions (otherwise the Nack Cause is displayed again): Set NTWCARDat NTWSNAPvalue (by means of SET BSCcommand), then load the Data Base again (by means of SETRUNNEW BSCOSUDB command); Set the Data Base to be loaded as backup (by means of SET BSCOSUDB command) and then perform a Full Bring Up. Example of Command Execution Setrunnew BSCOSUDB:NAME=BSCOSUDB:0; A30808-X3247-L230-3-7619 171 Commands Base Station Controller CML:BSC BSCOSUSW The BSCOSUSW(BSC Operational Software Unit SW) object is related to the software loads present on the BSC disk. Its attributes respectively identify the running, backup, new and fallback software load; an additional attribute is used to identify the current loading phase. The addressing scheme is not applicable (only 1 instance for this object is allowed); the object is automatically created and only the attribute values can be changed. GET BSCOSUSW Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUSW GET BSCOSUSW Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of the parameters selected by the operator by means of the REQATTL correspondent list. The validity range of the object address bscosuswn can be found in Appendix A. System Responses: GET BSCOSUSW NAME=BSCOSUSW:bscosuswn [,REQATTL=RUNESU, BCKUPESU, NEWESU, FALLBESU, PH]; GET ACK: RUNESU: runningESU BCKUPESU: backupESU NEWESU: newESU FALLBESU: fallbackESU PH: phase GET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. 172 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get BSCOSUSW:NAME=BSCOSUSW:0, REQATTL=RUNESU&BCKUPESU&NEWESU&FALLBESU&PH; GET BSCOSUSW BASICS Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUSW GET BSCOSUSW BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address bscosuswn can be found in Appendix A. System Responses: OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK An internal subsystem abort has occurred. GET BSCOSUSW BASICS NAME=BSCOSUSW:bscosuswn; GET ACK: RUNESU: runningESU BCKUPESU backupESU NEWESU: newESU FALLBESU: fallbackESU PH: phase GET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. A30808-X3247-L230-3-7619 173 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get BSCOSUSW BASICS:NAME=BSCOSUSW:0; GETINFO BSCOSUSW Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUSW GETINFO BSCOSUSW Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information about the BSCESUSW corresponding to runningESU or backupESU or newESU or fallbackESU attribute: 1. For each running ESU present in the system: BSCESUSW instance identier, User label associated, Version number, Operational state; 2. For each backup ESU present in the system: BSCESUSW instance identier, User label associated, Version number, Operational state; 3. For each new ESU present in the system: BSCESUSW instance identier, User label associated, Version number, Operational state; 4. For each fallback ESU present in the system: BSCESUSW instance identier, User label associated, Version number, Operational state; 5. Information about the load usage state. OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK An internal system abort has occurred. GETINFO BSCOSUSW NAME=BSCOSUSW:bscosuswn; 174 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller The validity range of the object address bscosuswn can be found in Appendix A. System Responses: GETINFO BSCOSUSW ACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** INFORMATION *** GETINFO REPORT BSCOSUSW: NAME = BSCOSUSW:1 RUNNING ESU INSTANCE: 0 USER LABEL: 62BSCHB010024 VERSION: 02-06-02-01-00-24_01-12-19 OPERATIONAL STATE: ENABLED BACKUP ESU INSTANCE: 0 USER LABEL: 62BSCHB010024 VERSION: 02-06-02-01-00-24_01-12-19 OPERATIONAL STATE: ENABLED FALLBACKUP ESU INSTANCE: 0 USER LABEL: 26207LOAD19 VERSION: 02-06-02-01-00-19_01-11-19 OPERATIONAL STATE: ENABLED NEW ESU INSTANCE: 0 USER LABEL: 26207LOAD19 VERSION: 02-06-02-01-00-19_01-11-19 OPERATIONAL STATE: ENABLED LOAD USAGE STATE: IDLE END OF REPORT GETINFO BSCOSUSW NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack BSCOSUSW: name = BSCOSUSW:1 nackCause = <nack cause> GETINFO NACK: NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 175 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Getinfo BSCOSUSW:NAME=BSCOSUSW:1; SET BSCOSUSW Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUSW SET BSCOSUSW Applicability: Phase 2. Visibility level 2. Command Description: This command performs an assignment of a generic software load to: backupESU BSCOSUSW attribute (BACKUPESU), or fallbackESU BSCOSUSW attribute (FALLBESU), or newESU BSCOSUSW attribute (NEWESU) . When runningESU BSCOSUSW attribute (RUNESU) is selected, this command performs: a Change Version when the object address bscosuswn corresponds to the object address contained into newESU BSCOSUSWattribute and the systemis in normal exercise. a Load System(Bring Up) when the object address bscosuswn corresponds to the object address contained into backupESU BSCOSUSWattribute and the systemis in normal exercise (BSCOSUSW LoadUsageState attribute set at IDLE). a Rollback when the object address bscosuswn corresponds to the object address contained into backupESU BSCOSUSW attribute and the system is during a Change Version (BSCOSUSWLoadUsageState attribute set at LoadNewESUsw or waitForAcceptNewESUsw). Note that the above-mentioned object address is different from the address of the BSCOSUSW object, which can assume the 0 value only (see below). In all the other cases a Nack to this command is given. That is: the command: T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. SET BSCOSUSW NAME=BSCOSUSW:bscosuswn, IDBSCESUSW=, ACTN=; 176 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SET BSCOSUSW NAME=bscosuswn ACTN=RUNNING_ESU (where bscosuswn is the object address contained into backupESU) corresponds to the command: SETRUNBACK BSCOSUSW (see the related command description and nack causes) Whereas: the command: SET BSCOSUSW NAME=bscosuswn ACTN=RUNNING_ESU (where bscosuswn is the object address contained into newESU) corresponds to the command: SETRUNNEW BSCOSUSW (see the related command description and nack causes) The validity range of the object address bscosuswn can be found in Appendix A. This command consists of two fields but only one can be used (NAME or USER LABEL SWLH). System Responses: Application Guidelines: 1. The system must be in normal exercise (no other operation is in progress). 2. If a generic software download is performed, in BACKUP directory, and it is not compatible with the corresponding Data Base of BSCOSUDB backupESU attribute, the attribute is set at NULL and an error message is displayed. 3. If a generic software download is performed, in NEW directory, and it is not compatible with the corresponding Data Base of BSCOSUDB newESUattribute, the attribute is set at NULL and an error message is displayed. 4. If a generic software download is performed, in FALLBACK directory, and it is not compatible with the corresponding Data Base of BSCOSUDB fallbackESUattribute, the attribute is set at NULL and an error message is displayed. SET ACK: SET NACK: NACK CAUSES: For a generic software load to newESU or fallbackESU attribute, the nack causes are: CMD_NOT_ALLOWED_IN_CURRENT_PHASE The BSCOSUSW LoadUsageState attribute is not IDLE. NO_ADMITTED_OPERATION The MEID object passed is not a valid one for the specific command. RELATED_OBJECTS_DISABLED The ESUSW MEID object passed by the command is DISABLED. INCONSISTENT_STATE_NCK An error during a Firmware function call happened. DISK_CROSSCOPY_IN_PROGRESS A disk crosscopy operation is in progress. A30808-X3247-L230-3-7619 177 Commands Base Station Controller CML:BSC 5. The system must be able to make actual the SW assignment also in the specic Firmware partition (SYS_BACKUP). Example of Command Execution Set BSCOSUSW:NAME=BSCOSUSW:0, IDBSCESUSW=BSCESUSW:0,ACTN=FALLBACK_ESU; Set BSCOSUSW:NAME=BSCOSUSW:0, IDBSCESUSW="userLabel",ACTN=FALLBACK_ESU; SETBACKNEW BSCOSUSW Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUSW SETBACKNEW BSCOSUSW Applicability: Phase 2. Visibility level 2. Command Description: This command performs an end of change version procedure or it is used to set generic software load at BSCOSUSW backupESU attribute. The validity range of the object address bscosuswn can be found in Appendix A. System Responses: SETBACKNEW BSCOSUSW NAME=BSCOSUSW:bscosuswn; SETBACKNEW ACK: SETBACKNEW NACK: NACK CAUSES: UNSUCCESSFUL_COMMAND_REJECTED An error during a function call happened. DISK_CROSSCOPY_IN_PROGRESS A disk crosscopy operation is in progress. CMD_NOT_ALLOWED_IN_CURRENT_PHASE The BSCOSUSW loadUsageState attribute is not waitForAcceptNewESUsw (for End of Change Version command only). The BSCOSUSW loadUsageState attribute is not IDLE (for the Set generic SW load to backupESU command only). NO_ADMITTED_OPERATION The MEID object passed is not a valid one for the specific command. The Change Version procedure was started from Radio Commander but the OMAL is still down (for End of Change Version only). The newESU SW is null (for End of Change Version only). The newESU DB is null (for End of Change Version with BU only). 178 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: If the system is in a "end of change version" phase, the command is performed when: the LoadUsageState of the BSCOSUSW attribute is equal to WAIT_FOR_ACCEPT_NEW_ESUSW; the OperationalState of BSCOSUSW newESU attribute is ENABLED. no crosscopy disks operation is in progress; if also MPCC was involved in Change Version, then BSCOSUDB newESU attribute must have OperationalState attribute ENABLED. Example of Command Execution Setbacknew BSCOSUSW:NAME=BSCOSUSW:0; SETRUNBACK BSCOSUSW Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUSW SETRUNBACK BSCOSUSW Applicability: Phase 2. Visibility level 2. Command Description: This command performs a bring-up or roll-back procedure. The validity range of the object address bscosuswn can be found in Appendix A. System Responses: RELATED_OBJECTS_DISABLED newESU SW is DISABLED (for End of Change Version command only). newESU DB is DISABLED (for End of Change Version command only). The object ESUSWMEID passed by the command is DISABLED (for the Set generic SW load to backupESU command only). INCONSISTENT_STATE_NCK An error during a Firmware function call happened (for the Set generic SW load to backupESU command only) SETRUNBACK BSCOSUSW NAME=BSCOSUSW:bscosuswn; SETRUNBACK ACK: SETRUNBACK NACK: NACK CAUSES: CMND_REJECTED_DUE_OTHER_CMND_IN_PROGRESS Bring Up in progress. A30808-X3247-L230-3-7619 179 Commands Base Station Controller CML:BSC Application Guidelines: 1. If the command is used to performa Bring Up procedure the OperationalState of the BSCOSUSW backup ESU attribute must be ENABLED and the number of MPCC copy providing service must be equal to the number of the On-board disk copy providing service. 2. If the LoadUsageState attribute value is equal to: IDLE, this command performs a Bring Up (Load System); LOAD_NEW_ESU_SW or WAIT_FOR_ACCEPT_NEW_ESU_SW, this command performs a Rollback procedure. In the former case the Rollback command is immediately executed, in the latter case al the loading operations in progress are aborted and the requested Rollback command is scheduled. If also MPCC was involved in the specic Change Version, then the number of MPCC copy providing service must be equal to the number of the On-board disk copy providing service; other value, this command is rejected because there a mismatch beetwen the command and LoadUsageState attribute. Example of Command Execution Setrunback BSCOSUSW:NAME=BSCOSUSW:0; SETRUNNEW BSCOSUSW Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUSW SETRUNNEW BSCOSUSW Applicability: Phase 2. Visibility level 2. UNSUCCESSFUL_COMMAND_REJECTED An error during a function call happened. NO_ADMITTED_OPERATION The MEID object passed is not a valid one for the specific command. MPCC and OB disk providing service copy numbers are not aligned. T_REQUEST_ALREADY_IN_PROGRESS A rollback command is already in progress. INCONSISTENT_STATE_NCK Mismatch between command and phase. RELATED_OBJECTS_DISABLED backupESU SW is DISABLED. CMD_NOT_ALLOWED_IN_CURRENT_PHASE The BSCOSUSW loadUsageState attribute is neither LoadNewESUsw nor waitForAcceptNewESUsw (for rollback command only). SETRUNNEW BSCOSUSW NAME=BSCOSUSW:bscosuswn; 180 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command triggers a Change Version procedure. The Change Version procedure allows the user to load a new software release. If the MPCC software has to be changed, a Bring Up will start. If the TDPC software has to be changed, both TDPC processor copies will be loaded with the new software, losing the traffic service for about 2 minutes: at the end of the command one copy is enabled with the new software and crosscopy operation fromthe TDPC active to the standby one is in progress. If the IXLT software has to be changed: if both the IXLTs are enabled, only the card not providing service is loaded with the new software, and the service is lost only for the switching time between the two processor copies. At the end of the command the copy with the new software is providing service, the other copy is disabled with the old software and it is automatically loaded when the SETBACKNEW BSCOSUSW command is entered if one of the IXLTs is not enabled, the command is not executed. If the PPCC software has to be changed: if both the PPCCs are enabled, only the copy provided by the Device Handler is loaded with the new software, and the service is lost only for the switching time between the two processor copies. At the end of the command the copy with the new software is enabled, the other copy is disabled with the old software and it is automatically loaded when the SETBACKNEW BSCOSUSW command is entered if one of the PPCCs is not enabled, the command is not executed. if no PPLD is PROVIDING SERVICE, the command is not executed. If the PPLD software has to be changed, all PPLD processor copies will be loaded with the new software, losing the traffic service for about 2-3 minutes. At the end of the command all equipped PPLDs are loaded with the new software and enabled. If the PPXL software has to be changed: if both PPXLs are enabled, only the copy provided by the Device Handler is loaded with the new software, and the service is lost only for the switching time between the two processor copies. At the end of the command the copy with the new software is enabled, the other copy is disabled with the old software and it is automatically loaded when the SETRUNNEW BSCOSUSW command is entered if one of the PPXLs is not enabled, the command is not executed. If the PPXU software has to be changed: if at least two PPXUs are enabled, half of the copies are loaded with the new soft- ware, and the service is lost only for the switching time between the two processor groups (the one with old software and the one with new software). At the end of the command all equipped PPXUs are loaded with the new software and enabled, the other processor group is disabled with the old software and it is automatically loaded when the SETBACKNEW BSCOSUSW command is entered. if only one PPXU is enabled, the command is not executed. If the PPXT software has to be changed, all PPXT processor copies will be loaded with th enewsoftware, losing th etraffic service for some minutes. At the end of the command all equipped PPTXTs are loaded with the new software and enabled. if no PPXT is PROVIDING SERVICE, the command is not executed. If the PPXP software has to be changed: If at least two PPXPs are enabled, half of the copies are loaded with the new soft- ware, and the service is lost only for the switching time between the two processor A30808-X3247-L230-3-7619 181 Commands Base Station Controller CML:BSC groups (the one with the old software and the newone with the newsoftware). At the end of the command the processor group loaded with the new software is enabled, the other processor group is disabled with the old software and it is automatically loaded when the SETBACKNEW BSCOSUSW command is entered. The procedure does not involve software change for the SNAP card. The command works only if the system is in normal exercise. The validity range of the object address bscosuswn can be found in Appendix A. System Responses: SETRUNNEW ACK: SETRUNNEW NACK: NACK CAUSES: CMND_REJECTED_DUE_OTHER_CMND_IN_PROGRESS Another operation is already in progress. UNSUCCESSFUL_COMMAND_REJECTED An error during a function call happened. NO_ADMITTED_OPERATION The MEID object passed is not a valid one for the specific command. The runningESU SW and the backupESU SW are not aligned. MPCC and OB Disk providing service copy numbers are not aligned (for Change Version with BU only). No object instance is linked to new ESU attribute (for Change Version with BU only). An ESU can be set as running only if it is already the backupESU or newESU. The backupESU SW is null. The specific newESU DB is not compatible with the Network type (for Change Version with BU only). T_REQUEST_ALREADY_IN_PROGRESS A Change Version command is already in progress. INCONSISTENT_STATE_NCK Mismatch between command and phase. The set of MPCC/TDPC/PPCU or MPCC/TDPC/PPXL/PPXU running patches are not equal to that one of permanent patches. The RSUEXE for the processor PPLD (or PPLD or PPCU or PPXL or PPXU) contained in the new ESU is DISABLED or missing. CMD_NOT_ALLOWED_IN_CURRENT_PHASE The BSCOSUSW loadUsageState attribute is not IDLE. RELATED_OBJECTS_DISABLED backupESU SW is DISABLED. newESU SW is DISABLED. newESU DB is DISABLED. SAME_VERSIONS Neither SW changes nor patch dis-alignment between newESU SW and backupESU SW for all processor types. DISK_CROSSCOPY_IN_PROGRESS A disk crosscopy operation is in progress. 182 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The system must be in normal exercise (no other operation is in progress). 2. The following state conditions must be satised: Load UsageState BSCOSUSW attribute must be IDLE; OperationalState BSCOSUSW backupESU must be ENABLED; OperationalState BSCOSUSW newESU must be ENABLED; the BSCOSUSW backupESU and BSCOSUSW runningESU attributes must be equal. 3. If also the MPCC processor is involved in Change Version procedure then: the BSCOSUDB newESU must be present and its OperationalState attribute must be ENABLED; the number of MPCC providing service copy must be equal to the number of the On-Board disk providing service copy; at least one copy for each processor type must be providing service. 4. If the IXLT, PPCC, PPCU, PPXL, PPXP and PPXU processors are involved in Change Version procedure then they must be in duplex mode, all cards must be in UNLOCKED-ENABLED state and at least one copy must be providing service. 5. If the PPLD processor is involved in Change Version procedure then at least one copy must be providing service. 6. The OperationalState attribute of all the RSUEXE objects related to the peripheral processor type foreseen in that BSCHWconguration and contained in the ESUSW must be ENABLED. This check is performed on peripheral processor type having at least one copy equipped only. 7. If the MEID object passed to the command by LMT system is equal to that one of backup BSCOSUSW, this command performs a Bring-Up procedure instead of a Change Version procedure. 8. The processors involved in Change Version operation are: those ones whose Software Version (SVR) is changed from backupESU to new ESU; those ones whose set of permanent patches related to backupESU is different from set of permanent patches related to newESU. NO_MINIMAL_CARD_REDUNDANCY IXLT processor is not in duplex. PPCC processor is not in duplex. PPCU processor is not in duplex. no IXLT processor providing service. no PPCC processor providing service. no PPCU processor providing service. no PPLD processor providing service. no MPCC processor providing service. no TDPC processor providing service. PPXL processor is not in duplex. PPXU processor is not in duplex. no PPXL processor providing service. no PPXU processor providing service. no PPXT providing service. no PPXP provideng service PPXP processor is not duplex A30808-X3247-L230-3-7619 183 Commands Base Station Controller CML:BSC If no processor is involved in change version (according to the conditions just listed) or change version regards not eqiopped optional peripheral processors only (i.e.: PPXU, PPXT and PPXP), then the change version is anyway accepted like an administrative chenge version operation (i.e.: a change version operation in which no processor loading is made). Example of Command Execution Setrunnew BSCOSUSW:NAME=BSCOSUSW:0; 184 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller A30808-X3247-L230-3-7619 185 Commands Base Station Controller CML:BSC BTS The BTS object locates a cell connected to BSC. It logically represents all the information related to the cell and to its configuration. CREATE BTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS CREATE BTS Applicability: Phase 2. CREATE BTS: NAME=BTSM:btsmn/BTS:btsn ,CELLGLID= ,BSIC= [,PLMNP=] [,CELLRESH=] [,MSTXPMAXGSM=] [,MSTXPMAXDCS=] [,MSTXPMAXPCS=] [,RXLEVAMI=] [,RDLNKTO=] [,RACHBT=] [,RACHLAS=] [,TCCCHLDI=] [,PCCCHLDI=] [,FACCHQ=] ,CELLTYP= ,SYSID= ,BCCHFREQ= [,CALLF<nn>=] [,CRESPARI=] [,CRESOFF=] [,TEMPOFF=] [,PENTIME=] [,CBQ=] [,NMULBAC=] [,CONCELL=] [,BTSHSCSD=] [,PUREBBSIG44CONF=] [,EHRACT=] [,HRACTT1=] [,HRACTT2=] [,SDCCHCONGTH=,] [,EEOTD=] [,AMRFRC1=] [,AMRFRTH12=] [,AMRFRC2=] [,AMRFRTH23=] [,AMRFRC3=] [,AMRFRTH34=] [,AMRFRC4=] [,AMRHRC1=] [,AMRHRTH12=] [,AMRHRC2=] [,AMRHRTH23=] [,AMRHRC3=] [,AMRHRTH34=] [,AMRHRC4=] [,AMRFRIC=] [,AMRHRIC=] [,AMRLKAT=] [,QSRHI=] [,FDDQMI=] [,FDDQO=] [,QSRHCINI=] [,FDDREPQTY=] [,FDDMURREP=] [,UMTSSRHPRI=] [,EANTHOP=] [,ANTHOPMOD=] [,ANTHOPP=] [,GUARMABIS=] [,QSRHC=] [,TDDQO=] [, TDDMURREP=] [,REPTYP=] [,ETXDIVTS=] [,TXDIVTSEXCPT=] [,TXDIVTSPAR=] [,TAADJ=] [,LCBM0=] [,LCBM1=] [,LCBM2=] [,LCBM3=] [HRACTAMRT1=] [HRACTAMRT2=] [EPAT1=] [EPAT2=][,MAXRETR=] [,NSLOTST=] [,NY1=] [,NBLKACGR=] [,NFRAMEPG=] [,MSTXPMAXCH=] [,PWROFS=] [,ASCISER=] [,NOCHFBLK=] [,NOCH- BLKN=] [ASCIULR=] [,INTCLASS=] [,INTAVEPR=] [,RFRSINDP=] [,CELLBARR=] [,CREALL=] [,NALLWACC=] [,EC=] [,SMSCBUSE=] [,DTXDLFR=] [,DTXDLHR=] [,DTXUL=] [,IMSIATDT=] [,HOPP=] [,T3212=] [,PWROUT=] [,DIRTCHASS=,] [,BMONTH=] [,BSMONTH=] [,EARCLM=] [,HOPMODE=,] [EXCDIST=] [,EEXCDIST=] [,EQ=] [,QL=] [,EPRE=] [,T200=] [,T3101=] [,T3105=] [,T3109=] [,T3111=] [,TSYNC=] [,TSYNCUL=,] [,TSYNCDL=] [,TSYNCR=] [,TTRAU=,] [ENANCD=] [,NCDP1=] [,NCDP2=] [,TGRANT=] [,NRPGRANT=] [,VGRULF=] [,TNOCH=] [,TUPLREP=] ; (where <nn> = 01 to 63) 186 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Visibility level 2. Command Description: This command sets the configuration of a cell specifying global parameters necessary for the creation. The attributes within this object describe the basic properties of a BTS which are not related to the Common Control Channels. All the other parameters will assume their default values if no other command is submitted. Moreover, this command implicitly creates the PWRC and HAND Managed Objects. Validity ranges of the object addresses "btsmn" and "btsn" can be found in Appendix A. System Responses: CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The BTSM instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. For more details see Application Guidelines n. 3, n. 8, n. 11, n. 12, n. 13, n. 17, n. 21, n. 25, n. 27, n. 31, n. 32, n. 35, n. 43, n. 50, n. 51. UNSUCCESSFUL_CELL_GLOB_ID All the fields of cellGlobalIdentity must be set in the following combination: MCC, MNC, LAC, CI, where: Location Area Identity (LAI) = MCC + MNC + LAC; Cell Global Identity = LAI + CI. The CELLGLID cannot be equal to the CELLGLID assigned to another BTS, TGTBTS, BTSTD, or TGTBTSTD. UNSUCCESSFUL_EQUAL_FREQ Frequencies set at the CALLF<nn> (cellAllocationF<nn>) attribute can not be equal; each frequency of CALLF attribute must be different from BCCH frequency value. WRONG_SYSID Make reference to Application Guidelines n. 4, n. 45, n. 46. UNSUCCESSFUL_FREQ_OUT_OF_RANGE Make reference to Application Guidelines n. 5 and n. 33. UNSUCCESSFUL_BCCF_OUT_OF_RANGE If SYSID = EXT900 the BCCF (broadcast frequency of the cell) must belong to the following range: 1 =< BCCF =< 124. UNSUCCESSFUL_VAR_OUT_OF_RANGE One or more variables have been incorrectly set. For more details see Application Guidelines n. 6, n. 14, n. 15, n. 16, n. 19, n. 20, n. 24, n. 34, n. 36, n. 37, n. 38, n. 44. INVALID_SVR BS-242 cannot support GSMR as SYSID (BTS object). A30808-X3247-L230-3-7619 187 Commands Base Station Controller CML:BSC BS-242 cannot support extended and concentric cells. BS-242 cannot support base band hopping (HOPMODE of BTS object). The parameter PUREBBSIG44CONF can only be set for BTS1 (BS-2x/6x) equipped with/without BBSIG44 devices. In case of BS-4x/240/241/240XL, BS-82 and BS-242 the attribute is meaningless and can only have the value <NULL>. The AMRHRCi attribute can not be set at value RATE_05 (7.40 kbit/s) if the SW version running on the superordinate BTSM belongs to BR6.0 release (see EXPSWV parameter description). INVALID_COMMAND The frequency hopping can be enabled only if there are some CHANs using a frequency hopping law different from 0. UNSUCCESSFUL_CBCH_NOTEQUIPPED To set SMSCBUSE at TRUE it is required that CBCH channel is already created, by setting either to BCBCH or SCBCH the CHTYPE attribute of the CHAN object. Before deletion of a created CBCH, SMSCBUSE has to be set at FALSE. UNSUCCESSFUL_HOPPING_SYSTEM_INCONSISTENT Make reference to Application Guidelines n. 22, n. 23, n. 26. UNSUCCESSFUL_SUBORDINATE_EQUIPPED The attribute HOPMODE (hoppingMode) can be set only if there are no subordinate frequency hopping systems equipped. HSCSD_TSC_INCONSISTENT If the HSCSD service is activated at BTS side (i.e. attribute BTSHSCSD of BTS set at TRUE) the HOPMODE can be set from BBHOP to SYNHOP only if in the cell the single TCHs on radio timeslot 0 have the same TSC of all the other single TCHs belonging to the superordinated TRX. UNSUCCESSFUL_MIXED_CELL_NOT_CONCENTRIC_CELL The cells GSMDCS, GSM850PCS and GSM850DCS have also to be concentric cells; if the SYSID parameter equals either to GSMDCS, GSM850PCS or GSM850DCS the CONCELL parameter must be set at TRUE. INVALID_RATE Make reference to Application Guidelines n. 36, n. 39, n. 40, n. 41, n. 42, n. 52. INCOMP_NESWLOAD_VS_MESSAGE The EANTHOP, ANTHOPMOD and ANTHOPP parameters cannot be set at NULL value if the RR sub-field of the EXPSWV parameter (see the parameter description) of the superordinate BTSM object is equal or greater than 15. The EANTHOP, ANTHOPMOD and ANTHOPP parameters must be set at NULL value if the RR sub-field of the EXPSWV parameter (see the parameter description) of the superordinate BTSM object is less than 15. The EANTHOP, ANTHOPMOD and ANTHOPP attributes are supported only by BS-240, BS-240XS and BS-82. The ETXDIVTScan not be set at TRUEif the SWversion running on the superordinate BTSM belongs to BR6.0 release (see EXPSWV parameter description). 188 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The management of the BTS managed object is split into the management of ve attribute groups: 2. The creation of a BTS implies the implicit creation of the HAND and PWRC Managed Objects. The ETXDIVTS can not be set at TRUE if the superordinate BTSM is of type BS-20, BS-21, BS-22, BS-60, BS-61, BS-82, BS-242. The GUARMABIS attribute must have NULL value if the SW Version running on the superordinate BTSM belongs to BR6.0 release (see EXPSWV parameter description). The GUARMABIS attribute cannot be set at NULL value if the SW Version running on the superordinate BTSM belongs to BR7.0 release (see EXPSWV parameter description). The REPTYP attribute can be set at ENHANCED value only if the SWVersion running on the superordinate BTSM belongs to BR7.0 release (see EXPSWV parameter description). The TAADJ attribute must have NULL value if the SW Version running on the superordinate BTSM belongs to BR6.0 release (see EXPSWV parameter description). The TAADJ attribute cannot be set at NULL value if the SW Version running on the superordinate BTSM belongs to BR7.0 release (see EXPSWV parameter description). UNSUCCESSFUL_INVALID_BCCH_FREQUENCY In GSMDCS/GSM850DCS cells: the band of BCCH frequency cannot be changed. UNSUCCESSFUL_FREQUENCY_CHANGE_NOT_ALLOWED In a GSMDCS/GSM850DCS mixed cell it is not possible to change a frequency value from one band of the cell to another if the frequency is already assigned to a TRX; this is due to the fact that the hardware of a TRX is not able to manage two different frequency bands. UNSUCCESSFUL_OVERLAP_BAND In GSMDCS/GSM850DCS and EXT900 cells, if the frequencies change, the involved MOBALLOC frequencies must remain in the same sub-band. UNSUCCESSFUL_CSCH3CSCH4_SUPPORTED In order to set PUREBBSIG44CONF at FALSE the subordinated PTPPKF object must have CSCH3CSCH4SUP set at FALSE. UNSUCCESSFUL_EXCEED_OBJECT_NBR With MPCCV7 board or old BSC rack type, no more than 250 BTS instances can be created in the whole BSC. BASIC BTS basic group CCCH BTS CCCH configuration group INTERF BTS interference level meas group OPTIONS BTS options group TIMER BTS timer group A30808-X3247-L230-3-7619 189 Commands Base Station Controller CML:BSC 3. Three attributes in the BTS Managed Object are formatted in digits; the attributes are: the MobileCountryCode (MCC) and the MobileNetworkCode (MNC) contained in the CellGlobalId (CELLGLID); the bSIdentityCode (BSIC); 4. The SYSID parameter can assume 10 values: BB900 (GSM Standard Band); F2ONLY900 (GSM Extended Band); EXT900 (GSM Mixed Band) GSMR (Railway Band) PCS1900 DCS1800 GSMDCS GSM850 GSM850PCS CELLGLID = MCC-MNC-LAC-CI Note that MCC = D1D2D3 MNC = D1D2D3 Dx means digit (only numerical characters shall be used; for numbers from 0 to 9 it must be entered one digit). In fact 9 is different from 09. For MCC all digits are mandatory while for MNC only D1 is mandatory. BSIC = D1D2 Dx means digit (only numerical characters 0..7 shall be used) Note that D1 is the NetworkColourCode (NCC) and D2 is the BTSColourCode (BCC) This attributes are stored in the system in their decimal representation (which is the input format) but it is necessary to check the range of each digit: MCC, MNC 0 =< Dx =< 9 BSIC 0 =< Dx =< 7 Do not configure cells without giving a value to the parameter Cell Identifier (CI) of the Cell Global Identifier attribute belonging to the BTS BASICS group because such cells are not handled by the system. 190 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GSM850DCS If the NETWTYPE parameter (previously set by the SET BSC command) is GSMDCS then only the BB900, F2ONLY900, EXT900, DCS1800 and GSMDCS values are permitted to the SYSID. If the NETWTYPE parameter is GSMRthen only the GSMRvalue is permitted to the SYSID. If the NETWTYPE parameter is GSMPCS then only the BB900, F2ONLY900, EXT900 and PCS1900 values are permitted to the SYSID. If the NETWTYPEparameter is GSM850PCSthen only GSM850, GSM850PCSand PCS1900 values are permitted to the SYSID. If there are not BB900 BTSs in the BSC the SYSID attribute can be F2ONLY900. If there are not F2ONLY900 BTSs in the BSC the SYSID attribute can be BB900. If the NETWTYPE parameter (previously set by the SET BSC command) is GSM850DCSthen only GSM850, GSM850DCSand DCS1800 values are permitted to the SYSID. 5. The frequencies set to CALL (cellAllocation) attribute must follow these rules: The difference between the frequency bands of F2ONLY900 and EXT900 is that in the second case the extended band (frequencies 0, 975...1023) can be used only for the trafc purposes and for phase 2 mobile, no interaction between the two bands (base and extended) are foreseen and the base band can be used also by phase 1 mobile. In case of F2ONLY900 the phase 1 mobile cannot support this conguration that is reserved for phase 2 mobile. Phase 1 mobile will not or only sporadically be able to set-up a call. For the US market (PCS1900 and the PCM24) the following frequency blocks are dened: if SYSID = BB900 then 1 =< frequency =< 124 if SYSID = F2ONLY900 then 0 =< frequency =< 124 975 =< frequency =< 1023 if SYSID = EXT900 then 0 =< frequency =< 124 975 =< frequency =< 1023 if SYSID = DCS1800 then 512 =< frequency =< 885 if SYSID = GSMR then 955 =< frequency =< 974 if SYSID = PCS1900 then 512 =< frequency =< 810 if SYSID = GSMDCS then 0 = < frequency =< 124 and 975 = < frequency =< 1023 (GSMextended band) 512 =< frequency =< 885 (DCS 1800) If SYSID = GSM850 then 128 =< frequency =< 251 If SYSID = GSM850PCS then 128 =< frequency =< 251 512 =< frequency =< 810 If SYSID = GSM850DCS then 128 =< frequency =< 251 (GSM 850) 512 =< frequency =< 885 (DCS 1800) A30808-X3247-L230-3-7619 191 Commands Base Station Controller CML:BSC The following considerations are valid only for the US market, if SYSID = PCS1900: all the frequencies of the CALLF (cellAllocation) must belong to one of the allowed frequencies; in particular, the maximumRF output power for the corner frequencies (512 and 810) is reduced of a xed quantity, depending on the CU type. The table below shows the amount of the reduction for different kinds of CUs. 6. For the different SYSID setting, the following msTxPwrMax parameters must be used: If SYSID equals BB900, EXT900, F2ONLY900, GSMDCS, GSMR, GSM850, GSM850PCS or GSM850DCS the MSTXPMAXGSM must be set. If SYSID equals DCS1800, GSMDCS or GSM850DCS the MSTXPMAXDCS must be set. If SYSID equals PCS1900 the MSTXPMAXPCS must be set. If SYSID equals GSMDCS or GSM850DCS the MSTXPMAXGSMmust be set at 2..15 (for the GSMpart of the cell), and the MSTXPMAXDCS must be set at 0..15 (for the DCS part of the cell). If SYSID equals GSM850PCS the MSTXPMAXGSMmust be set at 2..15 (for the GSMpart of the cell), and the MSTXPMAXPCS must be set at 0..15, 30 or 31 (for the PCS part of the cell). 7. After the creation of the object, the ADMINISTRATIVE state of this object is set at LOCKED. An UNLOCK command is required to put this object in service. 8. If CRESPARI =0 --> CRESOFF, TEMPOFF, PENTIME, CBQ are skipped. If CRESPARI =1 --> CRESOFF, TEMPOFF, PENTIME, CBQ are not skipped. 9. For frequencies of E-GSM no DUCOM may be used. No warning will be generated in case of use of DUCOM with E-GSM frequencies. 10. A cell congured with 6 TRXs and served by FTNF must be alarm supervised by ALCO of type Q300. 11. The value EXTCELL for the CELLTYP attribute is not accepted if the CONCELL parameter is set at TRUE. 12. The HSCSD service can be activated in the cell (BTSHSCSD = TRUE) only if the HSCSD service is activated at BSC side (ENHSCSD attribute of BSC set at TRUE). 13. In a GSMPCS network two BTS belonging to the same BTSM cannot have mixed GSM-PCS SYSID values. 14. If the BTS is a BS-82, it is not possible to create a BTS number for each BTSM greater than 8. from 512 to 585 for A block from 587 to 610 for D block from 612 to 685 for B block from 687 to 710 for E block from 712 to 735 for F block from 737 to 810 for C block CU type ARFCN 512 reduction ARFCN 810 reduction ECUPHPV3 8 dB 6 dB ECUPHPV4 8 dB 6 dB ECUPV2 4 dB 2 dB GCUPV1 4 dB 2 dB CUPV4 4 dB 4 dB 192 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 15. If the MAINBCCHor BCBCHchannel type is congured (see CHANobject) then the NBLKACGR attribute must not be higher than 2. 16. If the SCBCH channel type is congured (see CHAN object) then the NBLKACGR attribute must not be equal to 0. 17. To enable ASCISER, the NBLKACGR must be greater than NOCHBLKN. It is possible to enable ASCISER following the indications described in the next table: In case of not created channel please refer to MAINBCCH channel type case. 18. When Abis satellite links are used, due to introduction of additional delays between MS channel requests and BSCimmediate assignment commands, the probability of repeated requests from MS is increased depending on the value of the parameter NSLOTST. The NSLOTST value corresponding to a max waiting time before retransmission of the CHANNEL REQUEST is recommended. Additional SDCCHs are recommended to prevent congestion due to retransmission. 19. When the interference classication of idle trafc channels is enabled (INTCLASS attribute) the following attributes are relevant: The values of the interference boundaries are strictly increasing (00 <= x1 < x2 < x3 < x4 < 63, where xn = intThrBoun). x1, x2, x3 and x4 constitute the right boundaries of the interference bands they belong to. Example: x1 = 00 dBr (<= -110 dBm): x2, x3, x4 have xed values as follows: x2 = 03 dBr (<= -107 dBm) x3 = 61 dBr (<= -49 dBm) x4 = 62 dBr (<= -48 dBm) interference band 1 (dBm): - ..<= -110 interference band 2 (dBm): -110 <...<= -107 interference band 3 (dBm): -107 <...<= -49 interference band 4 (dBm): -49 <...<= -48 interference band 5 (dBm): -48 <...<= + All boundaries are coded as binary presentation of -X dBm decimal values. For the values make reference to Appendix B: Group 2. 20. For the attributes BMONTH and BSMONTH the following relationship must be satis- ed for the elds minor, major, critical: minor < major < critical. 21. For the attributes BMONTH and BSMONTH, regarding the ags minor, major, crit- ical and the relative threshold attributes, note that: NOCHFBLK NOCHBLKN Channel Type (CHTYPE) 1..4 1..4 5 1..3 MAINBCCH 6 1..2 7 1 1..3 1 MBCCHC or BCBCH averagingPeriod INTAVEPR interferenceThresholdBoundaries INTAVEPR rfResourceIndicationPeriod RFRSINDP A30808-X3247-L230-3-7619 193 Commands Base Station Controller CML:BSC if the ags are set at ENABLE the threshold values cannot be skipped; if the ags are set at DISABLE the threshold values must be skipped; if the ags are skipped also the threshold values must be skipped. 22. The frequency hopping can be enabled only if there are no channel instances with the same time slot using two different frequency hopping systems with the same common frequency. 23. The frequency hopping can be enabled only if the frequency belonging to a superordinate TRX of a non-hopping channel is not used in a frequency hopping system assigned to a hopping channel instance with the same timeslot number. 24. In case of Standard (Not Extended) Cell, the value of the attribute EXCDIST must be in range 1..35 km. 25. If the excessive distance is enabled (EEXCDIST = TRUE) the following attribute is relevant: excessiveDistance - EXCDIST attribute of HAND object. The value assigned to the attribute EXCDIST must be greater than the value assigned to the distance handover thresholds: hoThresholdMsRangeMax - attribute HOTMSRM of HAND object (in case of stan- dard cell); hoThresholdMsRangeMax - attribute HOTMSRME of HAND object (in case of extended cell). 26. The extended channels use two consecutive timeslots: therefore, in case of extended cell, all the previous Application Guidelines regarding frequency hopping consistency apply also to the timeslot following the channel timeslot. 27. In order to enable the HSCSDservice, the EARCLMattribute must be previously set at TRUE. 28. If EPRE parameter is set at TRUE value the timer BSCT7 of the BSC object must be set at a value between 6 and 254. 29. Within GSM Rec. 04.08, timer T3107 is specied for supervision of receipt of handover complete response assignment complete. In addition two timers with the same task are specied for BSSMAP, namely BSCT8 and BSCT10 (see BSC object). To make easier the handling of these timers only two of themare used within SBS. There is no lack in supervision of above named messages due to this imple- mentation, neither for internal nor for external handover procedures. 30. The timers TSYNC and TTRAU must be set longer than ALARMT2 (see LICD object). The timers TSYNC and TTRAU must be set longer than BSCT10 (BSC object) and BSCT8 (BSC object). This is to ensure that a signalling failure (BSCT8 and BSCT10) is detected before a transcoder failure (TSYNC and TTRAU). The attribute TSYNC should be equal to TTRAU attribute. 31. For the attribute NCDP2, the TimerNoCall2 eld can be set only if the StarTime2 eld is different from NOTUSED. 32. If the second time-frame is congured by the NCDP2 setting, the StartTime2 value must be greater than the StartTime1 eld of NCDP1 attribute. If the second time-frame is congured by the NCDP2 setting, the following congu- ration rule must be satised: a whole observation period must be present within each time-frame, i.e. TimerNoCall1 <= 6*(StartTime2 - StartTime1) TimerNoCall2 <= 6*((24 - (StartTime2 - StartTime1)) The two time-frames must be converted in periods of ten minutes. 194 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 33. The maximumnumber of frequencies that can be assigned to a cell depends on the delta between the lowest and the highest frequency given to the CALLFn attributes, as shown in the following table. 34. The ASCIULR attribute cannot be set at VBSENABLE, VGCSENABLE or VBC_VGCSENABLE if the ASCISER attribute is set at ASCI_DISABLED. 35. Each of the attributes MSTXPMAXGSM, MSTXPMAXDCS, MSTXPMAXPCS can be set only if the SYSID refers to the corresponding band; otherwise they must be skipped or assume the value <NULL>. 36. It is not possible to set all AMRFRCi (AMRHRCi) attributes at NULL; at least one value must be congured. 37. The following relations between the Threshold (TH) and Hysteresis (HYS) elds of two adjacent Codecs must be satised when the value of the AMRFRCi (AMRHRCi) attribute is changed: TH(i-1) <= TH(i) <= TH(i+1) i = 2,3 (TH + HYS)(i-1) <= (TH + HYS)(i) <= (TH + HYS)(i+1) 38. The AMRFRTHij (AMRHRTHij) attribute can be set at NULL value only if AMRFRCj (AMRHRCj) attribute is already set at NULL. 39. The value of the AMRFRCi (AMRHRCi) attribute must be smaller than the value of the AMRFRCi+1 (AMRHRCi+1) attribute. 40. If the AMRFRCi (AMRHRCi) attribute is not congured, also all the subsequent AMRFRCj (AMRHRCj) attributes have not to be congured (j > i). 41. The AMRHRCi attribute can not be set at value RATE_04 or RATE_05 for BSs 2x/6x. 42. The AMRFRIC (AMRHRIC) attribute must not be equal to CODEC_MODE_i value if the AMRFRCi (AMRHRCi) attribute is set at NULL value. 43. The EANTHOP (enableAntennaHopping) attribute can be enabled only if the HOPP (enableHopping) attribute is set at TRUE and the HOPMODE (hoppingMode) value is different from BBHOP (baseband hopping). 44. If the BTS is a BS-240XS, it is not possible to create for each BTSM a BTS number greater than 3. 45. If the BTS is a BS-240XS the SYSID cannot assume the values GSMDCS, GSM850PCS or GSM850DCS. 46. All the subordinate to a BS-240XS must have the same frequency range, no mixed congurations are allowed. The allowed congurations are: BB900 EXT900 F2ONLY PCS1900 DCS1800 GSMR GSM850. N. max Freq. Delta 16 Any 17 Any, if frequency 0 is present 18 512 22 256 29 128 64 111 or frequency in BB900 band A30808-X3247-L230-3-7619 195 Commands Base Station Controller CML:BSC 47. If the cell load dependent activation of Half Rate channels is enabled (by means of EHRACT parameter) in a cell congured as Extended or Concentric, the following rule applies: if no channels have been congured as TCHF_HLF (see CHTYPE parameter of CHAN object) in the Near/Inner area and a new request comes for an Half Rate channel to be assigned into the Near/Inner area, the system rst tries to assign a Full Rate channel into this area. If there are no available channels into the Near/Inner area, the systemassigns a Full Rate channel into the Far/Complete area (even though TCHF_HLF channels have been congured in the Far/Complete area). 48. In case of request with channel rate Full the pre-emption (which is enabled by means of EPRE parameter) is allowed only to vulnerable calls that are allocated on Full Rate channels. No preemption of Half Rate calls is performed. This restriction is due to impossibility, with actual implementation, to be sure that after pre-emption proce- dure the other part of the channel is still available. 49. LCBMx attributes can be set at a value different from NULL only if no CBCL instances have been already equipped. 50. The ETXDIVTS parameter can be set at TRUE only if (EANTHOP = FALSE and HOPP = FALSE) or (HOPP = TRUE and HOPMODE = SYNHOP). 51. The sum of the GUARMABIS attributes for the BTSs belonging to the same BTSM must be less or equal to 70. 52. The AMRHRCi attribute can be set at value RATE_05 (7.40 kbit/s) only if the BTS HW version is BTSplus. Example of Command Execution Create BTS:NAME=BTSM:0/BTS:0,CELLGLID="123"-"456"-1-1,BSIC=1-2, PLMNP=5,CELLRESH=5,MSTXPMAXGSM=5,MSTXPMAXDCS=<NULL>, MSTXPMAXPCS=<NULL>,RXLEVAMI=5,RDLNKTO=5,RACHBT=5, RACHLAS=102,TCCCHLDI=1,PCCCHLDI=255,FACCHQ=5,CELLTYP=STDCELL, SYSID=BB900 ,BCCHFREQ=2,CALLF01=123,CRESPARI=1,CRESOFF=2, TEMPOFF=1,PENTIME=2,CBQ=1,NMULBAC=1,CONCELL=FALSE, BTSHSCSD=FALSE,PUREBBSIG44CONF=FALSE,EHRACT=TRUE,HRACTT1=10, HRACTT2=12,SDCCHCONGTH=70,EEOTD=TRUE,AMRFRC1=RATE_01, AMRFRTH12=7-2,AMRFRC2=RATE_03,AMRFRTH23=12-2,AMRFRC3=RATE_06, AMRFRTH34=23-2,AMRFRC4=RATE_08,AMRHRC1=RATE_01, AMRHRTH12=19-0,AMRHRC2=RATE_02,AMRHRTH23=24-0, AMRHRC3=RATE_03,AMRHRTH34=26-0,AMRHRC4=RATE_04, AMRFRIC=START_MODE_FR,AMRHRIC=START_MODE_HR, AMRLKAT=100,QSRHI=OMDB78,FDDQMI=MDB17,FDDQO=DB12, QSRHCINI=ALWAYS,FDDREPQTY=RSCP,FDDMURREP=2,UMTSSRHPRI=TRUE, EANTHOP=FALSE,ANTHOPMOD=NOBCCHTRX,ANTHOPP=SECOND, GUARMABIS=0,QSRHC=UMDB78, TDDQO=8, TDDMURREP=2, REPTYP=NORMAL, ETXDIVTS=FALSE,TXDIVTSEXCPT=NONE,TXDVTSPAR=MDB1,TAADJ=1, LCBM0=NULL,LCBM1=NULL,LCBM2=NULL,LCBM3=NULL, HRACTAMRT1=6000,HRACTAMRT2=6000, EPAT1=6000, EPAT2=6000, MAXRETR=One,NSLOTST=0,NY1=1,NBLKACGR=2,NFRAMEPG=2, MSTXPMAXCH=0,PWROFS=0,ASCISER=ASCI_ENABLED, NOCHFBLK=1, NOCHBLKN=1,ASCIULR=ULRDISABLE, INTCLASS=TRUE, INTAVEPR=2-13-26-50-56,RFRSINDP=1,CELLBARR=FALSE, CREALL=NOTALLOWED,NALLWACC=na0,EC=FALSE,SMSCBUSE=TRUE, DTXDLFR=TRUE,DTXDLHR=TRUE,DTXUL=MAYFSHNH,IMSIATDT=FALSE, HOPP=TRUE,T3212=0,PWROUT=m8db -m6db -db3,DIRTCHASS=FALSE, 196 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BMONTH=Enabled(30)-Enabled(60)-Enabled(90), BSMONTH=Disabled(0)Disabled(0)Disabled(0),EARCLM=TRUE, HOPMODE=BBHOP,EXCDIST=1,EEXCDIST=FALSE,EQ=DISABLED,QL=30, EPRE=ENABLED,T200=44-31-41-90-90-90-135,T3101=HLFSEC-12,T3105=MS10-4, T3109=HLFSEC-30,T3111=HLFSEC-3,TSYNC=200,TSYNCUL=10,TSYNCDL=10, TSYNCR=200, TTRAU=200,ENANCD=DISABLED,NCDP1=H8-6,NCDP2=H21-30, TGRANT=100, NRPGRANT=10,VGRULF=8,TNOCH=3,TUPLREP=5; DELETE BTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS DELETE BTS Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a previously created BTS. Validity ranges of the object addresses "btsmn" and "btsn" can be found in Appendix A. System Responses: Application Guidelines: None. DELETE BTS: NAME=BTSM:btsmn/BTS:btsn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a BTS, the relative object instance must be in LOCKED state. UNSUCCESSFUL_SUBORDINATE_EQUIPPED All the LAPDLR, ADJC, FHSY, PTPPKF, SCA, CTRSCHED and RFLOOP object instances associated to the BTS object instance must be previously deleted. The BTS object instance cannot be deleted if it is referenced as the target cell by any ADJC object. COLOCATE_RELATIONSHIP_PRESENT If the BTS is defined colocated to other BTSs of the BSC, all the colocated relationships with other BTSs of the BSChave to be removed before deleting the BTS. A30808-X3247-L230-3-7619 197 Commands Base Station Controller CML:BSC Example of Command Execution Delete BTS:NAME=BTSM:0/BTS:0; GET BTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GET BTS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the cell global parameters of a previously created BTSB. Validity ranges of the object addresses "btsmn" and "btsn" can be found in Appendix A. GET BTS: NAME=BTSM:btsmn/BTS:btsn [,REQATTL=CELLGLID, BSIC, PLMNP, CELLRESH, MSTXPMAXGSM, MSTXPMAXDCS, MSTXPMAXPCS, RXLEVAMI, RDLNKTO, RACHBT, RACHLAS, TCCCHLDI, PCCCHLDI, FACCHQ, CELLTYP, SYSID, BCCHFREQ, CALLF<nn>, CRESPARI, CRESOFF, TEMPOFF, PENTIME, CBQ, NMULBAC, CONCELL, BTSHSCSD, PUREBBSIG44CONF, MAXRETR, NSLOTST, NY1, NBLKACGR, NFRAMEPG, MSTXPMAXCH, PWROFS, ASCISER, NOCHFBLK, NOCHBLKN, INTCLASS, INTAVEPR, RFRSINDP, CELLBARR, CREALL, NALLWACC, EC, SMSCBUSE, DTXDLFR, DTXDLHR, DTXUL, IMSIATDT, HOPP, T3212, PWROUT, DIRTCHASS, BMONTH, BSMONTH, EARCLM, HOPMODE, EXCDIST, EEXCDIST, EQ, QL, EPRE, T200, T3101, T3105, T3107, T3109, T3111, TSYNC, TSYNCUL, TSYNCDL, TSYNCR, TTRAU, ENANCD, NCDP1, NCDP2, TGRANT, NRPGRANT, VGRULF, TNOCH, EHRACT, HRACTT1, HRACTT2, SDCCHCONGTH, ASCIULR, TUPLREP, EEOTD, AMRFRC1, AMRFRTH12, AMRFRC2, AMRFRTH23, AMRFRC3, AMRFRTH34, AMRFRC4, AMRHRC1, AMRHRTH12, AMRHRC2, AMRHRTH23, AMRHRC3, AMRHRTH34, AMRHRC4, AMRFRIC, AMRHRIC, AMRLKAT, QSRHI, FDDQMI, FDDQO, QSRHCINI, FDDREPQTY, FDDMURREP, UMTSSRHPRI, EANTHOP, ANTHOPMOD, ANTHOPP, GUARMABIS, QSRHC, TDDQO, TDDMURREP, REPTYP, ETXDIVTS, TXDIVTSEXCPT, TXDIVTSPAR, TAADJ, LCBM0, LCBM1, LCBM2, LCBM3, HRACTAMRT1, HRACTAMRT2, EPAT1, EPAT2]; (where <nn> = 01 to 63) 198 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: GET ACK: NAME:name CELLGLID: MCC: mcc MNC: mnc LAC: lac CI: ci BSIC: bsIdentityCode NCC: Network Colour Code BCC: Bs Colour Code PLMNP: plmnPermitted CELLRESH: cellReselectHysteresis MSTXPMAXGSM: msTxPwrMaxGsm MSTXPMAXDCS: msTxPwrMaxDcs MSTXPMAXPCS: msTxPwrMaxPcs RXLEVAMI: rxLevAccessMin RDLNKTO: radioLinkTimeout RACHBT: rachBusyThreshold RACHLAS: rachLoadAveragingSlots TCCCHLDI: thresholdCcchLoadIndication PCCCHLDI: periodCcchLoadIndication FACCHQ: facchQual CELLTYP: cellType SYSID:systemIndicator BCCHFREQ:bcchFrequency CALLF01:cellAllocationF01 CALLF02:cellAllocationF02 CALLF03:cellAllocationF03 CALLF04:cellAllocationF04 CALLF05:cellAllocationF05 CALLF06:cellAllocationF06 CALLF07:cellAllocationF07 CALLF08:cellAllocationF08 CALLF09:cellAllocationF09 CALLF10:cellAllocationF10 CALLF11:cellAllocationF11 CALLF12:cellAllocationF12 CALLF13:cellAllocationF13 CALLF14:cellAllocationF14 CALLF15:cellAllocationF15 CALLF16:cellAllocationF16 CALLF17:cellAllocationF17 CALLF18:cellAllocationF18 CALLF19:cellAllocationF19 CALLF20:cellAllocationF20 CALLF21:cellAllocationF21 A30808-X3247-L230-3-7619 199 Commands Base Station Controller CML:BSC CALLF22:cellAllocationF22 CALLF23:cellAllocationF23 CALLF24:cellAllocationF24 CALLF25:cellAllocationF25 CALLF26:cellAllocationF26 CALLF27:cellAllocationF27 CALLF28:cellAllocationF28 CALLF29:cellAllocationF29 CALLF30:cellAllocationF30 CALLF31:cellAllocationF31 CALLF32:cellAllocationF32 CALLF33:cellAllocationF33 CALLF34:cellAllocationF34 CALLF35:cellAllocationF35 CALLF36:cellAllocationF36 CALLF37:cellAllocationF37 CALLF38:cellAllocationF38 CALLF39:cellAllocationF39 CALLF40:cellAllocationF40 CALLF41:cellAllocationF41 CALLF42:cellAllocationF42 CALLF43:cellAllocationF43 CALLF44:cellAllocationF44 CALLF45:cellAllocationF45 CALLF46:cellAllocationF46 CALLF47:cellAllocationF47 CALLF48:cellAllocationF48 CALLF49:cellAllocationF49 CALLF50:cellAllocationF40 CALLF51:cellAllocationF51 CALLF52:cellAllocationF52 CALLF53:cellAllocationF53 CALLF54:cellAllocationF54 CALLF55:cellAllocationF55 CALLF56:cellAllocationF56 CALLF57:cellAllocationF57 CALLF58:cellAllocationF58 CALLF59:cellAllocationF59 CALLF60:cellAllocationF60 CALLF61:cellAllocationF61 CALLF62:cellAllocationF62 CALLF63:cellAllocationF63 CRESPARI:cellReselectionParamInd CRESOFF:cellReselectOffset TEMPOFF:temporaryOffset PENTIME:penaltyTime CBQ:CellBarQualify 200 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller NMULBAC:nMultibandcell CONCELL:concentricCell BTSHSCSD:btsHSCSD MAXRETR:maxNumberRetrasmission NSLOTST:numberOfSlotSpreadTrans NY1:ny1 NBLKACGR:noOfBlocksForAccessGrant NFRAMEPG:noOfMultiFramesBetweenPaging MSTXPMAXCH:msTxPwrMaxCcch PWROFS:powerOffset ASCISER:advancedSpeechCallItemsService NOCHFBLK:notificationChannelFirstBlock NOCHBLKN:notificationChannelBlockNumber INTCLASS:enableInterferenceClass INTAVEPR:interferenceAveragingProcess averPeriod: averPeriod intThrBou1: intThrBou1 intThsBou2: intThsBou2 intThsBou3: intThsBou3 intThsBou4: intThsBou4 RFRSINDP:rfResourceIndicationPeriod CELLBARR:cellBarred CREALL:callReestablishmentAllowed NALLWACC: Not Allowed Access Class : notAllowedAccessClasses 0 Not Allowed Access Class : notAllowedAccessClasses 1 Not Allowed Access Class : notAllowedAccessClasses 2 Not Allowed Access Class : notAllowedAccessClasses 3 Not Allowed Access Class : notAllowedAccessClasses 4 Not Allowed Access Class : notAllowedAccessClasses 5 Not Allowed Access Class : notAllowedAccessClasses 6 Not Allowed Access Class : notAllowedAccessClasses 7 Not Allowed Access Class : notAllowedAccessClasses 8 Not Allowed Access Class : notAllowedAccessClasses 9 Not Allowed Access Class : notAllowedAccessClasses 10 Not Allowed Access Class : notAllowedAccessClasses 11 Not Allowed Access Class : notAllowedAccessClasses 12 Not Allowed Access Class : notAllowedAccessClasses 13 Not Allowed Access Class : notAllowedAccessClasses 14 Not Allowed Access Class : notAllowedAccessClasses 15 EC:emergencyCallRestricted SMSCBUSE:smsCBUsed DTXDLFR:dTxDownLinkFullRate DTXDLHR:dTxDownLinkHalfRate DTXUL:dTxUpLink IMSIATDT:allowImsiAttachDetach HOPP:enableHopping A30808-X3247-L230-3-7619 201 Commands Base Station Controller CML:BSC T3212:timerPeriodicUpdateMS PWROUT: Output Power Fault Threshold: oPwrFaultThreshold Reduced Output Power Threshold: redOutPwrThreshold Excessive Output Power Threshold: excesOutPwrThresh DIRTCHASS:directTCHAssign BMONTH:bintChanMonitorThresholds BSMONTH:bintSignChanMonitorThresholds EARCLMenableEarlyClassmark HOPMODE:hoppingMode EXCDIST:excessiveDistance EEXCDIST:enableExcessiveDistance EQ:enableQueuing QL:queuingLenght EPRE:enablePreemption T200: sdcchSAPIO:sdcchSAPIO facchTCHF: facchTCHF facchTCHH: facchTCHH sacchTCHSAPIO:sacchTCHSAPIO sacchSDCCH:sacchSDCCH sdcchSAPI3: sdcchSAPI3 sacchTCHSAPI3:sacchTCHSAPI3 T3101: Tunit:tunit Tvalue:tvalue T3105: Tunit:tunit Tvalue:tvalue T3107: Tunit: tunit Tvalue:tvalue T3109: Tunit:tunit Tvalue:tvalue T3111: Tunit:tunit Tvalue:tvalue TSYNC:tSync TTRAU:tTrau TSYNCUL:tSynchronizationUplink TSYNCDL:tSynchronizationDownlink TSYNCR:tSynchronizationR ENANCD:enableNoCallDetection NCDP1: StartTime1:StartTime1 TimerNoCall1:TimerNoCall1 202 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller NCDP2: StartTime2:StartTime2 TimerNoCall2:TimerNoCall2 TGRANT:timerGrant NRPGRANT:numberRepetitionGrant VGRULF:voiceGroupUplinkFree TNOCH:timerNotificationChannel EHHRACT:enableHrActivation HRACTT1:hRActivation Threshold1 HRACTT2:hRActivation Threshold2 SDCCHCONGTH:sdcchCongestionThreshold ASCIULR:asciUplinkReply TUPLREP:timerUplinkReply EEOTD:enableEOTD AMRFRC1:aMRFullRateCodec1 AMRFRTH12:aMRFullRateThresholds12 AMRFRC2:aMRFullRateCodec2 AMRFRTH23:aMRFullRateThresholds23 AMRFRC3:aMRFullRateCodec3 AMRFRTH34:aMRFullRateThresholds34 AMRFRC4:aMRFullRateCodec4 AMRHRC1:aMRHalfRateCodec1 AMRHRTH12:aMRHalfRateThresholds12 AMRHRC2:aMRHalfRateCodec2 AMRHRTH23:aMRHalfRateThresholds23 AMRHRC3:aMRHalfRateCodec3 AMRHRTH34:aMRHalfRateThresholds34 AMRHRC4:aMRHalfRateCodec4 AMRFRIC:aMRFullRateInitialCodec AMRHRIC:aMRHRInitialCodec AMRLKAT:aMRLinkAdapTuning QSRHI:qSearchI FDDQMI:fddQMin FDDQO:fddQOffset QSRHCINI:qSearchCinitial FDDREPQTY:fddReportingQuantity FDDMURREP:fddMultiratReporting UMTSSRHPRI:umtsSearchPriority EANTHOP:enableAntennaHopping ANTHOPMOD:antennaHoppingMode ANTHOPP:antennaHoppingPeriod GUARMABIS:guaranteedMinimumAbis QSRHC:qSearchC TDDQO:tddQOffset TDDMURREP: tddMultiratReporting REPTYP:reportType ETXDIVTS:enableTxDivTimeShift A30808-X3247-L230-3-7619 203 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get BTS:NAME=BTSM:0/BTS:0,REQATTL=CELLGLID&BSIC&PLMNP&CELLRESH& MSTXPMAXGSM&MSTXPMAXDCS&MSTXPMAXPCS&RXLEVAMI& RDLNKTO&RACHBT&RACHLAS&TCCCHLDI&PCCCHLDI&FACCHQ&CELLTYP& SYSID&BCCHFREQ&CALLF01&CALLF02&CALLF03&CALLF04&CALLF05& CALLF06&CALLF07&CALLF08&CALLF09&CALLF10&CALLF11&CALLF12& CALLF13&CALLF14&CALLF15&CALLF16&CALLF17&CALLF18&CALLF19& CALLF20&CALLF21&CALLF22&CALLF23&CALLF24&CALLF25&CALLF26& CALLF27&CALLF28&CALLF29&CALLF30&CALLF31&CALLF32&CALLF33& CALLF34&CALLF35&CALLF36&CALLF37&CALLF38&CALLF39&CALLF40& CALLF41&CALLF42&CALLF43&CALLF44&CALLF45&CALLF46&CALLF47& CALLF48&CALLF49&CALLF50&CALLF51&CALLF52&CALLF53&CALLF54& TXDIVTSEXCPT:txDivTimeShiftExcept TXDIVTSPAR:txDivTimeShiftParam TAADJ:taAdjust LCBM0:localCellBroadcastMessage0 MSGID:MSGID PAGE:PAGE REPRATE:REPRATE SCHEME:SCHEME LCBM1:localCellBroadcastMessage1 MSGID:MSGID PAGE:PAGE REPRATE:REPRATE SCHEME:SCHEME LCBM2:localCellBroadcastMessage2 MSGID:MSGID PAGE:PAGE REPRATE:REPRATE SCHEME:SCHEME LCBM3:localCellBroadcastMessage3 MSGID:MSGID PAGE:PAGE REPRATE:REPRATE SCHEME:SCHEME HRACTAMRT1: hRActivationAmrThreshold1 HRACTAMRT2: hRActivationAmrThreshold2 EPAT1: enhancedPairingThreshold1 EPAT2: enhancedPairingThreshold2 GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 204 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller CALLF55&CALLF56&CALLF57&CALLF58&CALLF59&CALLF60&CALLF61& CALLF62&CALLF63&CRESPARI&CRESOFF&TEMPOFF&PENTIME&CBQ& NMULBAC&CONCELL&BTSHSCSD&PUREBBSIG44CONF&MAXRETR& NSLOTST&NY1&NBLKACGR&NFRAMEPG&MSTXPMAXCH&PWROFS& ASCISER&NOCHFBLK&NOCHBLKN&INTCLASS&INTAVEPR&RFRSINDP& CELLBARR&CREALL&NALLWACC&EC&SMSCBUSE&DTXDLFR& DTXDLHR&DTXUL&IMSIATDT&HOPP&T3212&PWROUT&DIRTCHASS& BMONTH&BSMONTH&EARCLM&HOPMODE&EXCDIST&EEXCDIST&EQ&QL& EPRE&T200&T3101&T3105&T3107&T3109&T3111&TSYNC&TSYNCUL& TSYNCDL&TSYNCR&TTRAU&ENANCD&NCDP1&NCDP2&TGRANT&NRPGRANT& VGRULF&TNOCH&EHRACT&HRACTT1&HRACTT2&SDCCHCONGTH& ASCIULR&TUPLREP&EEOTD&AMRFRC1&AMRFRTH12&AMRFRC2& AMRFRTH23&AMRFRC3&AMRFRTH34&AMRFRC4&AMRHRC1&AMRHRTH12& AMRHRC2&AMRHRTH23&AMRHRC3&AMRHRTH34&AMRHRC4&AMRFRIC& AMRHRIC&AMRLKAT&QSRHI&FDDQMI&FDDQO&QSRHCINI&FDDREPQTY& FDDMURREP&UMTSSRHPRI&EANTHOP&ANTHOPMOD&ANTHOPP& GUARMABIS&QSRHC&TDDQTDDMURREP&REPTYP&ETXDIVTS&TXDIVT- SEXCPT&TXDIVTSPAR&TAADJ&LCBM0&LCBM1&LCBM2&LCBM3& HRACTAMRT1&HRACTAMRT2&EPAT1&EPAT2; GET BTS BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GET BTS BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses "btsmn" and "btsn" can be found in Appendix A. System Responses: GET BTS BASICS: NAME=BTSM:btsmn/BTS:btsn; GET ACK: NAME:name CELLGLID: MCC: mcc MNC: mnc LAC: lac CI: ci BSIC: bsIdentityCode NCC: Network Colour Code BCC: Bs Colour Code PLMNP: plmnPermitted A30808-X3247-L230-3-7619 205 Commands Base Station Controller CML:BSC CELLRESH: cellReselectHysteresis MSTXPMAXGSM: msTxPwrMaxGsm MSTXPMAXDCS: msTxPwrMaxDcs MSTXPMAXPCS: msTxPwrMaxPcs RXLEVAMI: rxLevAccessMin RDLNKTO: radioLinkTimeout RACHBT: rachBusyThreshold RACHLAS: rachLoadAveragingSlots TCCCHLDI: thresholdCcchLoadIndication PCCCHLDI: periodCcchLoadIndication FACCHQ: facchQual CELLTYP: cellType SYSID:systemIndicator BCCHFREQ:bcchFrequency CALLF01:cellAllocationF01 CALLF02:cellAllocationF02 CALLF03:cellAllocationF03 CALLF04:cellAllocationF04 CALLF05:cellAllocationF05 CALLF06:cellAllocationF06 CALLF07:cellAllocationF07 CALLF08:cellAllocationF08 CALLF09:cellAllocationF09 CALLF10:cellAllocationF10 CALLF11:cellAllocationF11 CALLF12:cellAllocationF12 CALLF13:cellAllocationF13 CALLF14:cellAllocationF14 CALLF15:cellAllocationF15 CALLF16:cellAllocationF16 CALLF17:cellAllocationF17 CALLF18:cellAllocationF18 CALLF19:cellAllocationF19 CALLF20:cellAllocationF20 CALLF21:cellAllocationF21 CALLF22:cellAllocationF22 CALLF23:cellAllocationF23 CALLF24:cellAllocationF24 CALLF25:cellAllocationF25 CALLF26:cellAllocationF26 CALLF27:cellAllocationF27 CALLF28:cellAllocationF28 CALLF29:cellAllocationF29 CALLF30:cellAllocationF30 CALLF31:cellAllocationF31 CALLF32:cellAllocationF32 CALLF33:cellAllocationF33 206 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller CALLF34:cellAllocationF34 CALLF35:cellAllocationF35 CALLF36:cellAllocationF36 CALLF37:cellAllocationF37 CALLF38:cellAllocationF38 CALLF39:cellAllocationF39 CALLF40:cellAllocationF40 CALLF41:cellAllocationF41 CALLF42:cellAllocationF42 CALLF43:cellAllocationF43 CALLF44:cellAllocationF44 CALLF45:cellAllocationF45 CALLF46:cellAllocationF46 CALLF47:cellAllocationF47 CALLF48:cellAllocationF48 CALLF49:cellAllocationF49 CALLF50:cellAllocationF40 CALLF51:cellAllocationF51 CALLF52:cellAllocationF52 CALLF53:cellAllocationF53 CALLF54:cellAllocationF54 CALLF55:cellAllocationF55 CALLF56:cellAllocationF56 CALLF57:cellAllocationF57 CALLF58:cellAllocationF58 CALLF59:cellAllocationF59 CALLF60:cellAllocationF60 CALLF61:cellAllocationF61 CALLF62:cellAllocationF62 CALLF63:cellAllocationF63 CRESPARI:cellReselectionParamInd CRESOFF:cellReselectOffset TEMPOFF:temporaryOffset PENTIME:penaltyTime CBQ:CellBarQualify NMULBAC:nMultibandcell CONCELL:concentricCell BTSHSCSD:btsHSCSD HRACTT1:hRActivation Threshold1 HRACTT2:hRActivation Threshold2 SDCCHCONGTH:sdcchCongestionThreshold EEOTD:enableEOTD AMRFRC1:aMRFullRateCodec1 AMRFRTH12:aMRFullRateThresholds12 AMRFRC2:aMRFullRateCodec2 AMRFRTH23:aMRFullRateThresholds23 AMRFRC3:aMRFullRateCodec3 A30808-X3247-L230-3-7619 207 Commands Base Station Controller CML:BSC AMRFRTH34:aMRFullRateThresholds34 AMRFRC4:aMRFullRateCodec4 AMRHRC1:aMRHalfRateCodec1 AMRHRTH12:aMRHalfRateThresholds12 AMRHRC2:aMRHalfRateCodec2 AMRHRTH23:aMRHalfRateThresholds23 AMRHRC3:aMRHalfRateCodec3 AMRHRTH34:aMRHalfRateThresholds34 AMRHRC4:aMRHalfRateCodec4 AMRFRIC:aMRFullRateInitialCodec AMRHRIC:aMRHRInitialCodec AMRLKAT:aMRLinkAdapTuning QSRHI:qSearchI FDDQMI:fddQMin FDDQO:fddQOffset QSRHCINI:qSearchCinitial FDDREPQTY:fddReportingQuantity FDDMURREP:fddMultiratReporting UMTSSRHPRI:umtsSearchPriority EANTHOP:enableAntennaHopping ANTHOPMOD:antennaHoppingMode ANTHOPP:antennaHoppingPeriod QSRHC:qSearchC TDDQO:tddQOffset TDDMURREP: tddMultiratReporting GUARMABIS:guaranteedMinimumAbis REPTYP:reportType ETXDIVTS:enableTxDivTimeShift TXDIVTSEXCPT:txDivTimeShiftExcept TXDIVTSPAR:txDivTimeShiftParam TAADJ:taAdjust LCBM0:localCellBroadcastMessage0 MSGID:MSGID PAGE:PAGE REPRATE:REPRATE SCHEME:SCHEME LCBM1:localCellBroadcastMessage1 MSGID:MSGID PAGE:PAGE REPRATE:REPRATE SCHEME:SCHEME LCBM2:localCellBroadcastMessage2 MSGID:MSGID PAGE:PAGE REPRATE:REPRATE SCHEME:SCHEME LCBM3:localCellBroadcastMessage3 208 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get BTS BASICS:NAME=BTSM:0/BTS:0; GET BTS CCCH Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GET BTS CCCH Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the CCCH group. Validity ranges of the object addresses "btsmn" and "btsn" can be found in Appendix A. System Responses: MSGID:MSGID PAGE:PAGE REPRATE:REPRATE SCHEME:SCHEME HRACTAMRT1: hRActivationAmrThreshold1 HRACTAMRT2: hRActivationAmrThreshold2 EPAT1: enhancedPairingThreshold1 EPAT2: enhancedPairingThreshold2 GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET BTS CCCH: NAME=BTSM:btsmn/BTS:btsn; GET ACK: NAME:name MAXRETR:maxNumberRetrasmission NSLOTST:numberOfSlotSpreadTrans NY1:ny1 NBLKACGR:noOfBlocksForAccessGrant NFRAMEPG:noOfMultiFramesBetweenPaging MSTXPMAXCH:msTxPwrMaxCcch PWROFS:powerOffset ASCISER:advancedSpeechCallItemsService A30808-X3247-L230-3-7619 209 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get BTS CCCH:NAME=BTSM:0/BTS:0; NOCHFBLK:notificationChannelFirstBlock NOCHBLKN:notificationChannelBlockNumber GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 210 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET BTS INTERF Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GET BTS INTERF Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the INTERF group. Validity ranges of the object addresses "btsmn" and "btsn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get BTS INTERF:NAME=BTSM:0/BTS:0; GET BTS OPTIONS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMBTS GET BTS OPTIONS GET BTS INTERF: NAME=BTSM:btsmn/BTS:btsn; GET ACK: NAME:name INTCLASS:enableInterferenceClass INTAVEPR:interferenceAveragingProcess averPeriod: averPeriod intThrBou1: intThrBou1 intThsBou2: intThsBou2 intThsBou3: intThsBou3 intThsBou4: intThsBou4 RFRSINDP:rfResourceIndicationPeriod GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET BTS OPTIONS: NAME=BTSM:btsmn/BTS:btsn; A30808-X3247-L230-3-7619 211 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the OPTIONS group. Validity ranges of the object addresses "btsmn" and "btsn" can be found in Appendix A. System Responses: GET ACK: NAME:name CELLBARR:cellBarred CREALL:callReestablishmentAllowed NALLWACC: Not Allowed Access Class : notAllowedAccessClasses 0 Not Allowed Access Class : notAllowedAccessClasses 1 Not Allowed Access Class : notAllowedAccessClasses 2 Not Allowed Access Class : notAllowedAccessClasses 3 Not Allowed Access Class : notAllowedAccessClasses 4 Not Allowed Access Class : notAllowedAccessClasses 5 Not Allowed Access Class : notAllowedAccessClasses 6 Not Allowed Access Class : notAllowedAccessClasses 7 Not Allowed Access Class : notAllowedAccessClasses 8 Not Allowed Access Class : notAllowedAccessClasses 9 Not Allowed Access Class : notAllowedAccessClasses 10 Not Allowed Access Class : notAllowedAccessClasses 11 Not Allowed Access Class : notAllowedAccessClasses 12 Not Allowed Access Class : notAllowedAccessClasses 13 Not Allowed Access Class : notAllowedAccessClasses 14 Not Allowed Access Class : notAllowedAccessClasses 15 EC:emergencyCallRestricted SMSCBUSE:smsCBUsed DTXDLFR:dTxDownLinkFullRate DTXDLHR:dTxDownLinkHalfRate DTXUL:dTxUpLink IMSIATDT:allowImsiAttachDetach HOPP:enableHopping T3212:timerPeriodicUpdateMS PWROUT: Output Power Fault Threshold: oPwrFaultThreshold Reduced Output Power Threshold: redOutPwrThreshold Excessive Output Power Threshold: excesOutPwrThresh DIRTCHASS:directTCHAssign BMONTH:bintChanMonitorThresholds BSMONTH:bintSignChanMonitorThresholds EARCLMenableEarlyClassmark 212 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get BTS OPTIONS:NAME=BTSM:0/BTS:0; GET BTS STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GET BTS STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the BTS object: Administrative State (AST) Operational State (OST) Usage State (UST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Unknown Status (UNK). Validity ranges of the object addresses "btsmn" and "btsn" can be found in Appendix A. System Responses: HOPMODE:hoppingMode EXCDIST:excessiveDistance EEXCDIST:enableExcessiveDistance EQ:enableQueuing QL:queuingLenght EPRE:enablePreemption GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET BTS STAT: NAME=BTSM:btsmn/BTS:btsn; GET BTS STAT ACK: GET BTS STAT NACK: A30808-X3247-L230-3-7619 213 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get BTS STAT:NAME=BTSM:0/BTS:0; GET BTS TIMER Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GET BTS TIMER Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the TIMER group. Validity ranges of the object addresses "btsmn" and "btsn" can be found in Appendix A. System Responses: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET BTS TIMER: NAME=BTSM:btsmn/BTS:btsn; GET ACK: NAME:name T200: sdcchSAPIO:sdcchSAPIO facchTCHF: facchTCHF facchTCHH: facchTCHH sacchTCHSAPIO:sacchTCHSAPIO sacchSDCCH:sacchSDCCH sdcchSAPI3: sdcchSAPI3 sacchTCHSAPI3:sacchTCHSAPI3 T3101: Tunit:tunit Tvalue:tvalue T3105: Tunit:tunit Tvalue:tvalue T3107: Tunit: tunit Tvalue:tvalue T3109: 214 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get BTS TIMER:NAME=BTSM:0/BTS:0; GETINFO BTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GETINFO BTS Applicability: Phase 2. Visibility level 2. Tunit:tunit Tvalue:tvalue T3111: Tunit:tunit Tvalue:tvalue TSYNC:tSync TTRAU:tTrau TSYNCUL:tSynchronizationUplink TSYNCDL:tSynchronizationDownlink TSYNCR:tSynchronizationR ENANCD:enableNoCallDetection NCDP1: StartTime1:StartTime1 TimerNoCall1:TimerNoCall1 NCDP2: StartTime2:StartTime2 TimerNoCall2:TimerNoCall2 TGRANT:timerGrant NRPGRANT:numberRepetitionGrant VGRULF:voiceGroupUplinkFree TNOCH:timerNotificationChannel TUPLREP:timerUplinkReply GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETINFO BTS: NAME=BTSM:btsmn/BTS:btsn; A30808-X3247-L230-3-7619 215 Commands Base Station Controller CML:BSC Command Description: This command is used to retrieve the following information: 1. The report complete indication. 2. The administrative state (AST), the operational state (OST), the usage state (UST), the availability status (AVS) and the procedural status (PRS) of the BTS. 3. The BTS absolute number. 4. The location of the signalling channels: BCCH, CBCH and SDCCH. 5. The barred cell information (status and reason); please note that the Cell Barred Status is not meaningful when cell is barred because there are no SS7Ls available or the operator directly bars the cell, setting the CBQ and CELLBARR attributes of the BTS. 6. The barred cell information. 7. The IsHopping information. 8. Switch beams EnableTxDiversityTimeShift. 9. Switch beams RX switch with current setting (values: PERIODICAL, NORMAL, DIVERSITY). 10. If the switch beam functionality has been enabled via patch: Switched beam capability, which can assume the following values: NONE, 4_BEAMS; Switched beam service state, which can assume the following values: OUT_OF_SERVICE, IN_SERVICE, DEGRADED_SERVICE, DISABLED_SERVICE. 11. The AntennaHoppingStatus information. 12. The Cell Global Identier information. 13. The Routing Area (RA) code. 14. The GPRS available information. 15. The BVCI. 16. Enable GPRS (TRUE/FALSE). 17. Enable EDGE (TRUE/FALSE). 18. The BTS capability (UNKNOWN, GSM, EDGE, NOT_APPLICABLE). 19. The BTS conguration (GSM, EDGE, NOT_APPLICABLE). 20. The BTS packet service availability (NONE, GPRS, EGPRS). 21. The BCCH TRX. 22. The location of the GPRS signalling channels: PBCCH and PCCCH. 23. The GPRS Maximum number of reserved PDCHs. 24. Full rate speech: number of CHANs used for full rate speech. 25. Full rate data: number of CHANs used for full rate data. 26. Half rate speech: number of subCHANs used for half rate speech calls (number of calls). 27. Packet: number of CHANs used for packet service. 28. For each TRX of the BTS: the state and statuses: AST, OST, UST, AVS, PRS; the TRX absolute number; the TRX capability (UNKNOWN, GSM, EDGE); the TRX mode (UNKNOWN, GSM, EDGE); the GPRS support (TRUE/FALSE). 29. For each CHAN of the TRX: the type, the pool type, the usage mode, the administrative, operational, usage states, the availability status and the used modality. 216 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Validity ranges of the object addresses "btsmn" and "btsn" can be found in Appendix A. System Responses: GETINFO BTS ACK: BSC_CONTROLLER -> LMT_LOCAL 03:21:35 01/01/1992 *** INFORMATION *** GET INFO REPORT BTS: NAME = BTS:112 REPORT COMPLETE: TRUE ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED USAGE STATE: IDLE AVAILABILITY STATUS: NONE PROCEDURAL STATUS: NONE BTS ABSOLUTE NR: 3 BCCH CHAN: 3-0-0 CBCH CHAN: 3-0-1 SDCCH CHAN: 3-0-1 3-0-2 3-0-3 3-2-1 3-1-2 3-1-3 3-1-4 3-1-6 ... ... CELL BARRED: TRUE CELL BARRED REASON: FAILED_HOPPING BTS IS HOPPING: TRUE ENABLE TX DIVERSITY TIME SHIFT: FALSE RX SWITCH CURRENT SETTING: PERIODICAL SWITCHED BEAM CAPABILITY: 4_BEAMS SWITCHED BEAM SERVICE STATE: DISABLED_SERVICE ANTENNA HOPPING STATUS: TRUE CELL GLOBAL ID: 123-32-387-984 RA CODE: 3 GPRS AVAILABLE: TRUE BVCI: 3 ENABLE GPRS: TRUE ENABLE EDGE: FALSE BTS CAPABILITY: EDGE BTS CONFIGURATION: EDGE BTS PACKET SERVICE AVAILABILITY: EGPRS BCCH TRX: 2 PBCCH MAP: 2 PCCCH MAP: 5 6 7 GPRS MAX. NUMBER PDCH RESERVED: 45 FULL SPEECH BUSY CH: 20 A30808-X3247-L230-3-7619 217 Commands Base Station Controller CML:BSC FULL DATA BUSY CH: 5 HALF SPEECH BUSY SUBCH: 3 PACKET BUSY CH: 5 TRX 0: ADMINISTRATIVE: UNLOCKED OPERATIONAL: ENABLED USAGE: IDLE AVAILABILITY: NONE PROCEDURAL: NONE TRX ABSOLUTE NUMBER: 567 TRX CAPABILITY: GSM TRX MODE: EDGE GPRS SUPPORTED: TRUE CHAN NR TYPE POOL TYPE USAGE MODE 0 FULL_RATE_ONLY NULL NULL 1 SDCCH NULL NULL 2 SDCCH NULL NULL 3 TCH_SD SDCCH_POOL NULL 4 TCH_SD TCH_POOL NULL 5 TCH_FULL NULL NULL 6 TCH_FULL NULL NULL 7 TCH_SD TCH_SD_POOL MODE_TCH CHAN NR ADMINISTRATIVE OPERATIONAL USAGE 0 UNLOCKED ENABLED NO USAGE STATE 1 UNLOCKED ENABLED IDLE 2 UNLOCKED ENABLED IDLE 3 UNLOCKED ENABLED IDLE 4 LOCKED ENABLED IDLE 5 UNLOCKED ENABLED BUSY 6 UNLOCKED ENABLED BUSY 7 UNLOCKED ENABLED BUSY CHAN NR AVAILABILITY MODE 0 NONE NO_DEDICATED 1 NONE NO_DEDICATED 2 NONE NO_DEDICATED 3 NONE NO_DEDICATED 4 NONE NO_DEDICATED 5 NONE CIRCUIT_SWITCH 6 NONE PACKET 7 NONE CIRCUIT_SWITCH TRX 1: ADMINISTRATIVE: UNLOCKED OPERATIONAL: DISABLED USAGE: IDLE AVAILABILITY: REMOTE_DEPENDENCY_OFF_LINE 218 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PROCEDURAL: NONE TRX ABSOLUTE NUMBER: 567 TRX CAPABILITY: GSM TRX MODE: EDGE GPRS SUPPORTED: TRUE CHAN NR TYPE POOL TYPE USAGE MODE 0 TCH_FULL NULL NULL 1 TCH_FULL NULL NULL 2 TCH_FULL NULL NULL 3 TCH_SD SDCCH_POOL NULL 4 TCH_SD TCH_POOL NULL 5 TCH_FULL NULL NULL 6 TCH_FULL NULL NULL 7 TCH_SD TCH_SD_POOL NULL CHAN NR ADMINISTRATIVE OPERATIONAL USAGE 0 UNLOCKED DISABLED NOT_APPLICABLE 1 UNLOCKED DISABLED NOT_APPLICABLE 2 UNLOCKED DISABLED NOT_APPLICABLE 3 UNLOCKED DISABLED NOT_APPLICABLE 4 LOCKED DISABLED NOT_APPLICABLE 5 UNLOCKED DISABLED NOT_APPLICABLE 6 UNLOCKED DISABLED NOT_APPLICABLE 7 LOCKED DISABLED NOT_APPLICABLE CHAN NR AVAILABILITY MODE 0 DEPENDENCY NO_DEDICATED 1 DEPENDENCY NO_DEDICATED 2 DEPENDENCY NO_DEDICATED 3 DEPENDENCY NO_DEDICATED 4 DEPENDENCY NO_DEDICATED 5 DEPENDENCY NO_DEDICATED 6 DEPENDENCY NO_DEDICATED 7 DEPENDENCY NO_DEDICATED ... ... END OF REPORT GETINFO BTS NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1*** Get Info Report Nack BTS: name = BTS:112 nackCause = <nack cause> A30808-X3247-L230-3-7619 219 Commands Base Station Controller CML:BSC Application Guidelines: 1. CELL BARRED Status attribute is not meaningful when the cell is barred because there are no SS7Ls available or when the operator directly bars the cell setting the attributes CBQ and CBA of the BTS. 2. The CELL BARRED REASON information is reserved for the developer. 3. TRXs that are not equipped in the BTS are not shown in the report. Example of Command Execution Getinfo BTS:NAME=BTSM:0/BTS:0; GETRELATIONSHIP BTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GETRELATION- SHIP BTS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of the all HMOs (Hardware Managed Object) supporting the FMO functionality. For the BTS object the related HMOs are the following: LICD/LICDS, EPWR, PPLD, PWRD, MPCC, TDPC, MEMT, NTW, PPXL and all the BTSE HMOs that implement the TRX functionality for a certain BTS. For BS-2x/6x, the BTSE HMOs are: ACOM, BBSIG, CCLK, CCTRL, FTNF, FVSWR, GPSU, LI, PA, RXMUCO, RXAMOD and TPU. For BS-4x/240/241/240XL, the BTSEHMOs are: COBA, COSA, CU, DIDCTMA, DILNA, DUDCTMA, DULNA, DUVSWR, FTNFP, FVSWRP and TMA. For BS-242, the BTSE HMOs are: CA, CCINT, CCSLINK, COBA, COSA and DCREFE. For the BS-82, the BTSE HMOs are: COBA, CU, DUVSWR and DULNA. NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the system. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. GETRELATIONSHIP BTS: NAME=BTSM:btsmn/BTS:btsn; 220 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Validity ranges of the object addresses "btsmn" and "btsn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship BTS:NAME=BTSM:0/BTS:0; GETSUBO BTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GETSUBO BTS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. Validity ranges of the object addresses "btsmn" and "btsn" can be found in Appendix A. System Responses GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The object does not provide any relationship attribute. GETSUBO BTS: NAME=BTSM:btsmn/BTS:btsn; GETSUBO ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GET BTS STATUS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 221 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Getsubo BTS:NAME=BTSM:0/BTS:0; LOCK BTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS LOCK BTS Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state "Locked". Validity ranges of the object addresses "btsmn" and "btsn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock BTS:NAME=BTSM:0/BTS:0; LOCK BTS: NAME=BTSM:btsmn/BTS:btsn; LOCK BTS ACK: LOCK BTS NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 222 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller MONITOR BTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS MONITOR BTS Applicability: Phase 2. Visibility level 1. Command Description: This command allows to display the alarm state of the interfaces. One object monitors the A interface, and there is one object to monitor the Abis interface for each BTS present in the BSC, and another object monitors the O&M interface. Validity ranges of the object addresses "btsmn" and "btsn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Monitor BTS:NAME=BTSM:0/BTS:0; MONITOR BTS: NAME=BTSM:btsmn/BTS:btsn; MONITOR BTS ACK: The output can be composed by one or more pack with a maximum number of five mnemonics of objects enqueued in the monitor queue specified; at the end, a message is displayed notifying the end of the monitor list. A30808-X3247-L230-3-7619 223 Commands Base Station Controller CML:BSC SET BTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SET BTS Applicability: Phase 2. Visibility level 2. SET BTS: NAME=BTSM:btsmn/BTS:btsn [,CELLGLID=] [,BSIC=] [,PLMNP=] [,CELLRESH=] [,MSTXPMAXGSM=] [,MSTXPMAXDCS=] [,MSTXPMAXPCS=] [,RXLEVAMI=] [,RDLNKTO=] [,RACHBT=] [,RACHLAS=] [,TCCCHLDI=] [,PCCCHLDI=] [,FACCHQ=] [,CELLTYP=] [,BCCHFREQ=] [,CALLF<nn>=] [,CRESPARI=] [,CRESOFF=] [,TEMPOFF=] [,PENTIME=] [,CBQ=] [,NMULBAC=] [,CONCELL=] [,BTSHSCSD=] [,PUREBBSIG44CONF=] [,EHRACT=] [,HRACTT1=] [,HRACTT2=] [,SDCCHCONGTH=,] [,EEOTD=] [,AMRFRC1=] [,AMRFRTH12=] [,AMRFRC2=] [,AMRFRTH23=] [,AMRFRC3=] [,AMRFRTH34=] [,AMRFRC4=] [,AMRHRC1=] [,AMRHRTH12=] [,AMRHRC2=] [,AMRHRTH23=] [,AMRHRC3=] [,AMRHRTH34=] [,AMRHRC4=] [,AMRFRIC] [,AMRHRIC=] [,AMRLKAT=] [,QSRHI=] [,FDDQMI=] [,FDDQO=] [,QSRHCINI=] [,FDDREPQTY=] [,FDDMURREP=] [,UMTSSRHPRI=] [,EANTHOP=] [,ANTHOPMOD=] [,ANTHOPP=] [,GUARMABIS=] [,QSRHC=] [,TDDQO=] [,TDDMURREP=] [,REPTYP=][,ETXDIVTS=] [,TXDIVTSEXCPT=] [,TXDIVTSPAR=] [,TAADJ=] [,LCBM0=] [,LCBM1=] [,LCBM2=] [,LCBM3=] [HRACTAMRT1=] [HRACTAMRT2=] [EPAT1=] [EPAT2=][,MAXRETR=] [,NSLOTST=] [,NY1=] [,NBLKACGR=] [,NFRAMEPG=] [,MSTXPMAXCH=] [,PWROFS=] [,ASCISER=] [,NOCHFBLK=] [,NOCH- BLKN=] [,ASCIULR=] [,INTCLASS=] [,INTAVEPR=] [,RFRSINDP=] [,CELLBARR=] [,CREALL=] [,NALLWACC=] [,EC=] [,SMSCBUSE=] [,DTXDLFR=] [,DTXDLHR=] [,DTXUL=] [,IMSIATDT=] [,HOPP=] [,T3212=] [,PWROUT=] [,DIRTCHASS=,] [,BMONTH=] [,BSMONTH=] [,EARCLM=] [,HOPMODE=,] [,EXCDIST=] [,EEXCDIST=] [,EQ=] [,QL=] [,EPRE=] [,T200=] [,T3101=] [,T3105=] [,T3109=] [,T3111=] [,TSYNC=] [,TSYNCUL=,] [TSYNCDL=] [,TSYNCR=] [,TTRAU=,] [,ENANCD=] [,NCDP1=] [,NCDP2=] [,TGRANT=] [,NRPGRANT=] [,VGRULF=] [,TNOCH=] [,TUPLREP=]; (where <nn> = 01 to 63) 224 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command modifies the configuration of a cell by specifying the global parameters necessary for the creation. The attributes within this object describe the basic properties of a BTS which are not related to the Common Control Channels. Validity ranges of the object addresses "btsmn" and "btsn" can be found in Appendix A. System Responses: SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_BCCH_FREQUENCY Make reference to Application Guidelines n. 9 and n. 17. UNSUCCESSFUL_CELL_GLOB_ID Make reference to Application Guidelines n. 1, n. 3, n. 10, n.68. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. For more details see Application Guidelines n. 2, n. 7, n. 11, n. 12, n. 15, n. 20, n. 24, n. 26, n. 30, n. 34, n. 35, n. 40, n. 41, n. 50, n. 54, n. 55, n. 63, n. 64, n. 66, n. 67. UNSUCCESSFUL_EQUAL_FREQ The attribute CALLF<nn> must not contain twice the same frequency and it must not contain the frequency entered in the attribute BCCHFREQ. UNSUCCESSFUL_FREQ_OUT_OF_RANGE Make reference to Application Guidelines n. 4 and n. 52. UNSUCCESSFUL_BCCF_OUT_OF_RANGE If SYSID = EXT900 the BCCF (broadcast frequency of the cell) must belong to the following range: 1 =< bccf =< 124. UNSUCCESSFUL_TRX_FREQ_NOT_FOUND The carrier frequencies of the already equipped TRXs must be among the CALL (cellAllocation) attributes. UNSUCCESSFUL_VAR_OUT_OF_RANGE Make reference to Application Guidelines n. 5, n. 14, n. 18, n. 19, n. 22, n. 23, n. 31, n. 39, n. 42, n. 43, n. 44. UNSUCCESSFUL_INVALID_STATUS Make reference to Application Guidelines n. 6, n. 36, n. 37, n. 62. UNSUCCESSFUL_SUBORDINATE_EQUIPPED Make reference to Application Guidelines n. 8, n. 13, n. 25. FHSY_FREQ_NOT_FOUND The frequencies of the already equipped frequency hopping systems must be among the CALL<nn> (cellAllocation) attributes. A30808-X3247-L230-3-7619 225 Commands Base Station Controller CML:BSC HSCSD_HOPP_INCONSISTENT The attribute BTSHSCSD can be set at TRUE only if the following requirements are satisfied: 1) Case Base Band Hopping Mode: on a given TRX, single TCHs on timeslot from1 to 7 must have the same FHSYD and MAIO. If at least one CCCH has already been equipped, the MOBALLOC of the FHSY object instance cannot contain the BCCH frequency and all channels on the BCCH-TRX cannot hop (i.e. FHSYD attribute must be 0). 2) Case Synthesizer Hopping Mode: on a given TRX different fromthe BCCH one, all single TCHs must have the same FHSYD. TIMER_EXPIRED The BCCH change procedure is failed for time out. INVALID_SVR BS-242 cannot support extended and concentric cells. BS-242 cannot support base band hopping (HOPMODE of BTS object). The parameter PUREBBSIG44CONFIG can only be set for BTS1 (BS-2x/6x) equipped with/without BBSIG44 devices. In case of BS-4x/240/241/240XL, BS-82 and BS-242 the attribute is meaningless and can only have the value <NULL>. The AMRHRCi attribute can not be set at value RATE_05 (7.40 kbit/s) if the SW version running on the superordinate BTSM belongs to BR6.0 release (see EXPSWV parameter description). BCCF_AND_BSIC_BELONG_TO_ANOTHER_CELL The serving and target adjacent cells cannot have the same BCCH-BSIC pair. INVALID_COMMAND The frequency hopping can be enabled only if there are some CHANs using a frequency hopping law different from 0. UNSUCCESSFUL_CBCH_NOTEQUIPPED To set SMSCBUSE at TRUE it is required that CBCH (BCBCH or SCBCH) channel is already created. Before deletion of a created CBCH, SMSCBUSE has to be set at FALSE. UNSUCCESSFUL_HOPPING_SYSTEM_INCONSISTENT The frequency hopping can be enabled only if there are no channel instances with the same time slot using two different frequency hopping systems with the same common frequency. The frequency hopping can only be enabled if the frequency belonging to a superordinate TRX of a non-hopping channel is not used in a frequency hopping system assigned to a hopping channel instance with the same timeslot number. In case of extended cell make reference to Application Guideline n. 28. HSCSD_TSC_INCONSISTENT Make reference to Application Guidelines n. 16 and n. 29. 226 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller UNSUCCESSFUL_FREQUENCY_UNDER_MEASURE The BCCH frequency cannot be changed if the BTS is the target cell of an ADJC which has its BCCH frequency traced by the relative SCA (see NMDLATT<nn> parameters). UNSUCCESSFUL_MIXED_CELL_NOT_CONCENTRIC_CELL The cells GSMDCS, GSM850PCS and GSM850DCS have also to be concentric cells; if the SYSID parameter equals either to GSMDCS, GSM850PCS or GSM850DCS the CONCELL parameter must be set at TRUE. UNSUCCESSFUL_FREQUENCY_CHANGE_NOT_ALLOWED In a GSMDCS mixed cell and in a GSM850PCS cell it is not possible to change a frequency value from one band of the cell to the other if the frequency is already assigned to a TRX; this is due to the fact that the hardware of a TRX is not able to manage two different frequency bands. INVALID_RATE Make reference to Application Guidelines n. 45, n. 46, n. 47, n. 48, n. 49. UNSUCCESSFUL_NO_MORE_FREQ_AVAILABLE The maximumnumber of frequencies that can be assigned to a cell has been reached. For more details see Application Guideline n. 38. UNSUCCESSFUL_FREQ_IN_USE A frequency can be removed only if it is not in use by any TRX or FHSY. UNSUCCESSFUL_OVERLAP_BAND When SYSIDis equal to GSMDCS, EXT900 or GSM850PCS, if the frequencies belonging to the MOBALLOC are changed, the new set of frequencies must remain in the same sub-band. MAX_ADJC_COMPL_BAND_EXCEEDED The number of adjacent cells having their BCCHFREQ in the complementary band exceeds the allowed maximum number. For more details, see Application Guideline n. 53. UNSUCCESSFUL_INVALID_BCCF The serving and target adjacent cells cannot have the same BCCH frequency. INCOMP_NESWLOAD_VS_MESSAGE The EANTHOP, ANTHOPMOD and ANTHOPP parameters cannot be set at NULL value if the RR sub-field of the EXPSWV parameter (see the parameter description) of the superordinate BTSM object is equal or greater than 15. The EANTHOP, ANTHOPMOD and ANTHOPP parameters must be set at NULL value if the RRsub-field of the EXPSWV parameter (see the parameter description) of the superordinate BTSMobject is less than 15. The EANTHOP, ANTHOPMOD and ANTHOPP attributes are supported only by BS-240, BS-240XS and BS-82. The ETXDIVTS can not be set at TRUE if the SWversion running on the superordinate BTSM belongs to BR6.0 release (see EXPSWV parameter description). A30808-X3247-L230-3-7619 227 Commands Base Station Controller CML:BSC Application Guidelines: 1. The cellGlobalIdentity (MCC, MNC, LAC, CI) must be set at the following combination: 2. Three attributes in the BTS Managed Object are formatted in digits; the attributes are: the MobileCountryCode (MCC) and the MobileNetworkCode (MNC) contained in the CellGlobalId (CELLGLID); the bSIdentityCode (BSIC); The ETXDIVTS can not be set at TRUE if the superordinate BTSM is of type BS-20, BS-21, BS-22, BS-60, BS-61, BS-82, BS-242. The GUARMABIS attribute must have NULL value if the SW Version running on the superordinate BTSM object belongs to BR6.0 release (see EXPSWV parameter description). The GUARMABIS attribute cannot be set at NULL value if the SW Version running on the superordinate BTSM object belongs to BR7.0 release (see EXPSWV parameter description). The REPTYP attribute can be set at ENHANCED value only if the SWVersion running on the superordinate BTSMbelongs to BR7.0 release (see EXPSWV parameter description). The TAADJ attribute must have NULL value if the SW Version running on the superordinate BTSMbelongs to BR6.0 release (see EXPSWV parameter description). The TAADJ attribute cannot be set at NULL value if the SW Version running on the superordinate BTSM belongs to BR7.0 release (see EXPSWV parameter description). MCC, MNC, LAC, CI where: Location Area Identity (LAI) = MCC + MNC + LAC Cell Global Identity = LAI + CI If one field is skipped it assumes the OLD value. CELLGLID = MCC-MNC-LAC-CI Note that MCC = D1D2D3 MNC = D1D2D3 Dx means digit (only numerical characters shall be used; for numbers from 0 to 9 it must be entered one digit). In fact 9 is different from 09. For MCC all digits are mandatory while for MNC only D1 is mandatory. BSIC = D1D2 Dx means digit (only numerical characters 0..7 shall be used) Note that D1 is the NetworkColourCode (NCC) and D2 is the BTSColourCode (BCC) This attributes are stored in the system in their decimal representation (which is the input format) but it is necessary to check the range of each digit: 228 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 3. The "cellGlobalIdentity" (MCC, MNC, LAC, CI) must be different from the "cellGlobalIdentity" of all the other BTSs of the BSC. 4. The frequencies set to CALL (cellAllocation) attribute must follow these rules: The difference between the frequency bands of F2ONLY900 and EXT900 is that in the second case the extended band (frequencies 0, 975...1023) can be used only for the trafc purposes and for phase 2 mobile, no interaction between the two bands (base and extended) are foreseen and the base band can be used also by phase 1 mobile. In case of F2ONLY900 the phase 1 mobile cannot support this conguration that is reserved for phase 2 mobile. Phase 1 mobile will not or only sporadically be able to set-up a call. For the US market (PCS1900 and the PCM24) the following frequency blocks are dened: The following considerations are valid only for the US market, if SYSID = PCS1900: all the frequencies of the CALLF (cellAllocation) must belong to one of the allowed MCC, MNC 0 =< Dx =< 9 BSIC 0 =< Dx =< 7 Do not configure cells without giving a value to the parameter Cell Identifier (CI) of the Cell Global Identifier attribute belonging to the BTS BASICS group because such cells are not handled by the system. if SYSID = BB900 then 1 =< frequency =< 124 if SYSID = F2ONLY900 then 0 =< frequency =< 124 975 =< frequency =< 1023 if SYSID = EXT900 then 0 =< frequency =< 124 975 =< frequency =< 1023 if SYSID = DCS1800 then 512 =< frequency =< 885 if SYSID = GSMR then 955 =< frequency =< 974 if SYSID = PCS1900 then 512 =< frequency =< 810 if SYSID = GSMDCS then 0 = < frequency =< 124 and 975 = < frequency =< 1023 (GSMextended band) 512 =< frequency =< 885 (DCS 1800) If SYSID = GSM850 then 128 =< frequency =< 251 If SYSID = GSM850PCS then 128 =< frequency =< 251 512 =< frequency =< 810 If SYSID = GSM850DCS then 128 =< frequency =< 251 (GSM 850) 512 =< frequency =< 885 (DCS 1800) from 512 to 585 for A block from 587 to 610 for D block from 612 to 685 for B block from 687 to 710 for E block from 712 to 735 for F block from 737 to 810 for C block A30808-X3247-L230-3-7619 229 Commands Base Station Controller CML:BSC frequencies; in particular, the maximumRF output power for the corner frequencies (512 and 810) is reduced of a xed quantity, depending on the CU type. The table below shows the amount of the reduction for different kinds of CUs. 5. For the different SYSID setting, the following msTxPwrMax parameters must be used: If SYSID equals BB900, EXT900, F2ONLY900, GSMDCS, GSMR, GSM850, GSM850PCS or GSM850DCS the MSTXPMAXGSM must be set. If SYSID equals DCS1800, GSMDCS or GSM850DCS the MSTXPMAXDCS must be set. If SYSID equals PCS1900 or GSM850PCS the MSTXPMAXPCS must be set. If SYSID equals GSMDCS or GSM850DCS the MSTXPMAXGSMmust be set at 2..15 (for the GSMpart of the cell), and the MSTXPMAXDCS must be set at 0..15 (for the DCS part of the cell). If SYSID equals GSM850PCS the MSTXPMAXGSMmust be set at 2..15 (for the GSMpart of the cell), and the MSTXPMAXPCS must be set at 0..15, 30 or 31 (for the PCS part of the cell). 6. The BSIC (bsIdentityCode) and the CELLGLID (cellGlobalIdentity) attribute can be set if the BTS object is LOCKED: if the administrative state is LOCKED the command is accepted; if the administrative state is UNLOCKED the command is not accepted. 7. If CRESPARI=0 --> CRESOFF, TEMPOFF, PENTIME, CBQ are skipped. If CRESPARI=1 --> CRESOFF, TEMPOFF, PENTIME, CBQ are not skipped. 8. The attribute CONCELL can be set only if no subordinated TRXs are equipped. 9. In case of synthesizer frequency hopping (HOPMODE attribute in BTS object), the BCCFREQ (broadcast frequency of the cell) cannot be included in a frequency hopping system. 10. The CELLGLID cannot be equal to the CELLGLID of an equipped subordinated ADJC (internal or external). 11. In order to change the frequencies of the cell no other attribute can be modied at the same time. 12. The value EXTCELL of cellType attribute is not accepted if the value of the concen- tricCell attribute is TRUE. 13. The cellType attribute can be changed fromEXTCELL to STDCELL, and viceversa, only if all subordinated channels are deleted. 14. When the cellType attribute changes from EXTCELL to STDCELL, the value of the attribute excessiveDistance must be in narrow range 1..35 km. In case of Standard (Not Extended) Cell, the value of the attribute EXCDIST must be in range 1..35 km. 15. The HSCSD service can be activated in the cell (BTSHSCSD set at TRUE) only if the HSCSD service is activated at BSC side (ENHSCSD attribute of BSC is set at TRUE). CU type ARFCN 512 reduction ARFCN 810 reduction ECUPHPV3 8 dB 6 dB ECUPHPV4 8 dB 6 dB ECUPV2 4 dB 2 dB GCUPV1 4 dB 2 dB CUPV4 4 dB 4 dB 230 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 16. If the HSCSD service is activated at BTS side (i.e. attribute BTSHSCSD of BTS object set at TRUE) the following TSC requirements must be satised: Case Base Band Hopping Mode: on a given TRX, single TCHs on timeslot from 1 to 7 must have the same TSC. Case Synthesizer Hopping Mode: on a given TRX all single TCHs must have the same TSC. The command is rejected if some TSCs are set at the same value and the others are skipped. Pay attention that if the value assigned to those TSCs is the same of BCC eld of BSIC attribute, the GET system response shows that all the TSCs have the same value but the HSCSD service cannot be enabled. 17. In case of GSMDCS, GSM850PCS or GSM850DCS cells, the band of the BCCH frequency cannot be changed. 18. If the MAINBCCHor BCBCHchannel type is congured (see CHANobject) then the NBLKACGR attribute must not be higher than 2. 19. If the SCBCH channel type is congured (see CHAN object) then the NBLKACGR attribute must not be equal to 0. 20. To enable ASCISER, the NBLKACGR must be greater than NOCHBLKN. It is possible to enable ASCISER following the indications described in the next table: In case of not created channel please refer to MAINBCCH channel type case. 21. When Abis satellite links are used, due to introduction of additional delays between MS channel requests and BSCimmediate assignment commands, the probability of repeated requests from MS is increased depending on the value of the parameter NSLOTST. The NSLOTST value corresponding to a max waiting time before retransmission of the CHANNEL REQUEST is recommended. Additional SDCCHs are recommended to prevent congestion due to retransmission. 22. When the interference classication of idle trafc channels is enabled (INTCLASS attribute) the following attributes are relevant: NOCHFBLK NOCHBLKN Channel Type (CHTYPE) 1..4 1..4 5 1..3 MAINBCCH 6 1..2 7 1 1..3 1 MBCCHC or BCBCH A30808-X3247-L230-3-7619 231 Commands Base Station Controller CML:BSC The values of the interference boundaries are strictly increasing (00 <= x1 < x2 < < x3 < x4 < 63, where xn = intThrBoun). x1, x2, x3 and x4 constitute the right boundaries of the interference bands they belong to. Example: x1 = 00 dBr (<= -110 dBm): x2, x3, x4 have xed values as follows: x2 = 03 dBr (<= -107 dBm) x3 = 61 dBr (<= -49 dBm) x4 = 62 dBr (<= -48 dBm) interference band 1 (dBm): - ..<= -110 interference band 2 (dBm): -110 <...<= -107 interference band 3 (dBm): -107 <...<= -49 interference band 4 (dBm): -49 <...<= -48 interference band 5 (dBm): -48 <...<= + All boundaries are coded as binary representation of -X dBm decimal values. For the values make reference to Appendix B: Group 2. 23. For the attributes BMONTH and BSMONTH the following relationship must be satis- ed for the elds minor, major, critical: minor < major < critical. 24. For the attributes BMONTH and BSMONTH, regarding the ags minor, major, crit- ical and the relative threshold attributes, note that: if the ags are set at ENABLE the threshold values cannot be skipped; if the ags are set at DISABLE the threshold values must be skipped; if the ags are skipped also the threshold values must be skipped. 25. The attribute HOPMODE (hoppingMode) can be set only if there are no subordinate frequency hopping systems equipped. 26. If the excessive distance is enabled (EEXCDIST= TRUE), the value assigned to the attribute EXCDIST must be greater than the value assigned to the distance handover thresholds: hoThresholdMsRangeMax - attribute HOTMSRM of HAND object (in case of stan- dard cell); hoThresholdMsRangeMax - attribute HOTMSRME of HAND object (in case of extended cell). 27. If the excessive distance is enabled (EEXCDIST=TRUE) the following attribute is relevant: excessiveDistance - EXCDIST attribute of HAND object. 28. The extended channels use two consecutive timeslots: therefore, in case of extended cell, all the previous Application Guidelines regarding frequency hopping consistency apply also to the timeslot following the channel timeslot. 29. If the HSCSD service is activated at BTS side (i.e. attribute BTSHSCSD of BTS is set at TRUE) the HOPMODE can be set fromBBHOP to SYNHOP only if in the cell the single TCHs on radio timeslot 0 have the same TSC of all the other single TCHs belonging to the superordinated TRX. 30. In order to enable the HSCSDservice, the EARCLMattribute must be previously set at TRUE. averagingPeriod INTAVEPR interferenceThresholdBoundaries INTAVEPR rfResourceIndicationPeriod RFRSINDP 232 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 31. If EPRE parameter is set at TRUE value the timer BSCT7 of the SET BSCcommand must be set at a value between 6 and 254. 32. Within GSM Rec. 04.08, timer T3107 is specied for supervision of receipt of handover complete response assignment complete. In addition two timers with the same task are specied for BSSMAP, namely BSCT8 and BSCT10 (see BSC object). To make easier the handling of these timers only two of themare used within SBS. There is no lack in supervision of above named messages due to this imple- mentation, neither for internal nor for external handover procedures. 33. The timers TSYNC and TTRAU must be set longer than ALARMT2 (see LICD object). The timers TSYNC and TTRAU must be set longer than BSCT10 (see BSC object) and BSCT8 (BSC object). This is to ensure that a signalling failure (BSCT8 and BSCT10) is detected before a transcoder failure (TSYNC and TTRAU). The attribute TSYNC should be equal to TTRAU attribute. 34. For the attribute NCDP2, the TimerNoCall2 eld can be set only if the StarTime2 eld is different from NOTUSED. 35. If the second time-frame is congured by the NCDP2 setting, the StartTime2 value must be greater than the StartTime1 eld of NCDP1 attribute. If the second time-frame is congured by the NCDP2 setting, the following congu- ration rule must be satised: 36. In order to set BCCHFREQ, CELLGLID, BSIC, CALLF<nn> parameters, the relative SCA object must be in "Locked" state. 37. In order to set the CELLGLID attribute, if the BTS is referred as adjacent of a BTS for which a SCA has been created, the SCA must be locked. 38. The maximumnumber of frequencies that can be assigned to a cell depends on the delta between the lowest and the highest frequency given to the CALLFn attributes, as shown in the following table. 39. The ASCIULR attribute cannot be set at VBSENABLE, VGCSENABLE or VBC_VGCSENABLE if the ASCISER attribute is set at ASCI_DISABLED. 40. Each of the attributes MSTXPMAXGSM, MSTXPMAXDCS, MSTXPMAXPCS can be set only if the SYSID refers to the corresponding band; otherwise they must be skipped or assume the value <NULL>. 41. It is not possible to change more AMRFRCi (AMRHRCi) attributes at the same time. 42. It is not possible to set all AMRFRCi (AMRHRCi) attributes at NULL; at least one value must be congured. a whole observation period must be present within each time-frame, i.e. TimerNoCall1 <= 6*(StartTime2 - StartTime1) TimerNoCall2 <= 6*((24 - (StartTime2 - StartTime1)) The two time-frames must be converted in periods of ten minutes. N. max Freq. Delta 16 Any 17 Any if freq.0 is present 18 512 22 256 29 128 64 111 or frequency in BB900 band A30808-X3247-L230-3-7619 233 Commands Base Station Controller CML:BSC 43. The following relations between the Threshold (TH) and Hysteresis (HYS) elds of two adjacent Codecs must be satised when the value of the AMRFRCi (AMRHRCi) attribute is changed: TH(i-1) <= TH(i) <= TH(i+1) i = 2,3 (TH + HYS)(i-1) <= (TH + HYS)(i) <= (TH + HYS)(i+1) 44. The AMRFRTHij (AMRHRTHij) attribute can be set at NULL value only if the AMRFRCj (AMRHRCj) attribute is already set at NULL. 45. The value of the AMRFRCi (AMRHRCi) attribute must be smaller than the value of the AMRFRCi+1 (AMRHRCi+1) attribute. 46. If the AMRFRCi (AMRHRCi) attribute is not congured, also all the subsequent AMRFRCj (AMRHRCj) attributes have not to be congured (j > i). 47. The attribute AMRHRCi can not be set at value RATE_04 or RATE_05 for BSs 2x/6x. 48. The AMRFRIC (AMRHRIC) attribute must not be equal to CODEC_MODE_i value if the AMRFRCi (AMRHRCi) attribute is set at NULL value. 49. The ag EEOTD cannot be set at TRUE if existing channels on bcch trx have TSC different from NULL. 50. The new BCCH frequency must not be used by any of the adjacent cells. 51. In case of EXT900, if any subordinate TRX has some signalling channel subordi- nated then its carrier frequency must be in the range 1..124. 52. Frequencies can be changed if all the hopping laws involved do not have CHAN instances that point to them. 53. The maximumnumber of adjacent cells having their BCCHFREQin the complemen- tary band, with respect to the SYSID of the serving cell, depends on the delta between the lowest and the highest frequency of the ADJC belonging to this subset, as shown in the following table. 54. The HOPMODE (hoppingMode) attribute can not be set at BBHOP (baseband hopping) if Antenna Hopping is enabled. 55. The EANTHOP (enableAntennaHopping) attribute can be enabled only if the HOPP (enableHopping) attribute is set at TRUE and the HOPMODE value is different from BBHOP. 56. If the cell load dependent activation of Half Rate channels is enabled (by means of EHRACT parameter) in a cell congured as Extended or Concentric, the following rule applies: if no channels have been congured as TCHF_HLF (see CHTYPE parameter of CHAN object) in the Near/Inner area and a new request comes for an Half Rate channel to be assigned into the Near/Inner area, the system rst tries to assign a Full Rate channel into this area. If there are no available channels into the Near/Inner area, the systemassigns a Full Rate channel into the Far/Complete area (even though TCHF_HLF channels have been congured in the Far/Complete area). Max Number of ADJC in complementary Band Delta 16 Any 17 Any, if frequency 0 is present 18 512 22 256 29 128 All 111 or frequency in BB900 band 234 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 57. In case of request with channel rate Full the pre-emption (which is enabled by means of EPRE parameter) is allowed only to vulnerable calls that are allocated on Full Rate channels. No preemption of Half Rate calls is performed. This restriction is due to impossibility, with actual implementation, to be sure that after pre-emption proce- dure the other part of the channel is still available. 58. LCBMx attributes can be set at a value different from NULL only if no CBCL instances have been already equipped. 59. The EANTHOP parameter can not be set at TRUE if the ETXDIVTS parameter is set at TRUE. 60. If the ETXDIVTS parameter is set at TRUE the HOPP parameter can be set at TRUE only with HOPMODE = SYNHOP. 61. The HOPMODE parameter can not be set at a value different from SYNHOP if the ETXDIVTS parameter is set at TRUE. 62. The ETXDIVTS, TXDIVTSEXCPT, TXDIVTSPAR parameters can be set only if the BTS object is in LOCKED state. 63. The ETXDIVTS parameter can be set at TRUE only if (EANTHOP = FALSE and HOPP = FALSE) or (HOPP = TRUE and HOPMODE = SYNHOP) and no SWIBEAM objects are equipped. 64. The sum of the GUARMABIS attributes for the BTSs belonging to the same BTSM must be less or equal to 70. 65. The AMRHRCi attribute can be set at value RATE_05 (7.40 kbit/s) only if the BTS HW version is BTSplus. 66. The FDDREPQTY attribute cannot be set at Ec_No if the EUIMPHO attribute (see HAND object) is set at True. 67. The NBLKACGR attribute must be set at a value > 0 when one UTRAN neighbour cell has been congured. 68. The CELLGLID cannot be equal to the CELLGLID assigned to another BTS, TGTBTS, BTSTD, or TGTBTSTD. Example of Command Execution Set BTS:NAME=BTSM:0/BTS:0,CELLGLID="123"-"456"-1-1,BSIC=1-2, PLMNP=5,CELLRESH=5,MSTXPMAXGSM=5,MSTXPMAXDCS=<NULL>, MSTXPMAXPCS=<NULL>,RXLEVAMI=5,RDLNKTO=5,RACHBT=5, RACHLAS=102,TCCCHLDI=1,PCCCHLDI=255,FACCHQ=5,CELLTYP=STDCELL, BCCHFREQ=2,CALLF01=123,CRESPARI=1,CRESOFF=2, TEMPOFF=1, PENTIME=2,CBQ=1,NMULBAC=1,CONCELL=FALSE,BTSHSCSD=FALSE, PUREBBSIG44CONF=FALSE,EHRACT=TRUE,HRACTT1=10,HRACTT2=12, SDCCHCONGTH=70,EEOTD=TRUE,AMRFRC1=RATE_01,AMRFRTH12=7-2, AMRFRC2=RATE_03,AMRFRTH23=12-2,AMRFRC3=RATE_06, AMRFRTH34=23-2,AMRFRC4=RATE_08,AMRHRC1=RATE_01, AMRHRTH12=19-0,AMRHRC2=RATE_02,AMRHRTH23=24-0,AMRHRC3=RATE_03, AMRHRTH34=26-0,AMRHRC4=RATE_04,AMRFRIC=START_MODE_FR, AMRHRIC=START_MODE_HR,AMRLKAT=100,QSRHI=OMDB78,FDDQMI=MDB17, FDDQO=DB12,QSRHCINI=ALWAYS,FDDREPQTY=RSCP,FDDMURREP=2, UMTSSRHPRI=TRUE,EANTHOP=FALSE,ANTHOPMOD=NOBCCHTRX, ANTHOPP=SECOND,GUARMABIS=0,QSRHC=UMDB78,TDDQO=8, TDDMURREP=2, REPTYP=NORMAL,ETXDIVTS=FALSE,TXDIVTSEXCPT=NONE, TXDVTSPAR=MDB1,TAADJ=1,LCBM0=NULL,LCBM1=NULL,LCBM2=NULL, LCBM3=NULL,HRACTAMRT1=6000,HRACTAMRT2=6000, EPAT1=6000, EPAT2=6000, MAXRETR=One,NSLOTST=0,NY1=1,NBLKACGR=2,NFRAMEPG=2, MSTXPMAXCH=0,PWROFS=0,ASCISER=ASCI_ENABLED,NOCHFBLK=1, A30808-X3247-L230-3-7619 235 Commands Base Station Controller CML:BSC NOCHBLKN=1,ASCIULR=ULRDISABLE,INTCLASS=TRUE, INTAVEPR=2-13-26-50-56,RFRSINDP=1,CELLBARR=FALSE, CREALL=NOTALLOWED,NALLWACC=na0,EC=FALSE,SMSCBUSE=TRUE, DTXDLFR=TRUE,DTXDLHR=TRUE,DTXUL=MAYFSHNH,IMSIATDT=FALSE, HOPP=TRUE,T3212=0,PWROUT=m8db -m6db -db3,DIRTCHASS=FALSE, BMONTH=Enabled(30)-Enabled(60)-Enabled(90), BSMONTH=Disabled(0)Disabled(0)Disabled(0),EARCLM=TRUE, HOPMODE=BBHOP,EXCDIST=1,EEXCDIST=FALSE,EQ=DISABLED,QL=30, EPRE=ENABLED,T200=44-31-41-90-90-90-135,T3101=HLFSEC-12, T3105=MS10-4,T3109=HLFSEC-30,T3111=HLFSEC-3,TSYNC=200,TSYNCUL=10, TSYNCDL=10,TSYNCR=200, TTRAU=200,ENANCD=DISABLED,NCDP1=H8-6, NCDP2=H21-30,TGRANT=100, NRPGRANT=10,VGRULF=8,TNOCH=3, TUPLREP=5; SHUTDOWN BTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SHUTDOWN BTS Applicability: Phase 2. Visibility level 1. Command Description: This command allows the graceful transition of an object from the administrative state "Unlocked" to the administrative state "Locked" after the object has terminated its current activity. The BSS is able to force a mobile station to perform an intercell or inter-BSC HO by means of the O&M SHUTDOWN command. After the SHUTDOWN command is entered, the system tries to perform an intercell or inter-BSC HO per mobile station; in case of failure, a further attempt is performed every 30 seconds for the next 5 minutes period. If after the predefined period (5.5 minutes) the current activity is not terminated, the administrative state will be set at Locked. If one of the objects is still active or busy after the predefined period, ongoing calls will be dropped. Validity ranges of the object addresses "btsmn" and "btsn" can be found in Appendix A. System Responses: SHUTDOWN BTS: NAME=BTSM:btsmn/BTS:btsn; SHUTDOWN BTS ACK: SHUTDOWN BTS NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 236 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. If the operator has started too many shutdown commands, the system will display the SM TOO BUSY message. 2. Possible state transitions and timing: a) UNLOCKED -immediately-> SHUTTING DOWN ---------- immediately ----------> LOCKED b) UNLOCKED -immediately-> SHUTTING DOWN ---------- 5.5 minutes ----------> LOCKED c) UNLOCKED -immediately-> SHUTTING DOWN ---------- after object went to idle state ----------> LOCKED The state changes described above show all the possible transitions when the shut- down command was performed. The rst column of the table gives the situations which are affected by doing a shut- down of an object. Example of Command Execution Shutdown BTS:NAME=BTSM:0/BTS:0; UNLOCK BTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS UNLOCK BTS Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state "Unlocked". Validity ranges of the object addresses "btsmn" and "btsn" can be found in Appendix A. System Responses: SITUATIONS TRANSITIONS FORCED/NOT FORCED idle object a) busy object but not released after the SHUTDOWN command b) busy object but released after the SHUTDOWN command c) UNLOCK BTS: NAME=BTSM:btsmn/BTS:btsn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED A30808-X3247-L230-3-7619 237 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Unlock BTS:NAME=BTSM:0/BTS:0; The object instance must be already equipped. ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. 238 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BTSM The BTSM object provides services to control the functionalities of one or more BTSs located at the same site. It performs all the operation and maintenance functions common to all transceivers. CREATE BTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM CREATE BTSM Applicability: Phase 2. Visibility level 2. Command Description: The object BTSMrepresents the O&Mfunctionality related to a site and not to a specific BTS. A BTSM object is a logical grouping of one or more BTSs with common management needs. A consequence of this command is that also a BTSE object with the identical instance number will come into existence and can be queried e.g. for its attributes. The validity range of the object address "btsmn" can be found in Appendix A. System Responses: CREATE BTSM: NAME=BTSM:btsmn ,EXPSWV= [,SHLAPDIT=] [,OMLAPDRT=] [,EMT1=] [,EMT2=] [,SALUNAME=] [,PCMCON0=] [,PCMCON1=] [,PCMCON2=] [,PCMCON3=] [,FLAPDOVLTH=] [,SLAPDOVLTH=] [,LAPDOVLT=] ,TEI= [,LPDLMSAT=] [,ABISHRACTTHR=] [,ABISTRFHITHR=] [,ABISTRFLTHR=] [,GASTRABISTH=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The field pcmbNumber of the attributes PCMCONx (x = 1..4) must specify the PCMB carrying the LPDLM associated to the BTSM (there must be at least one LPDLM per each BTSM connected). The PCMB lines specified in all the given PCMCONx (x = 1..4) attributes must be already equipped. A30808-X3247-L230-3-7619 239 Commands Base Station Controller CML:BSC Application Guidelines: 1. After the creation of the object the ADMINISTRATIVE state of this object is set at LOCKED. An UNLOCK command is required to put this object in service. 2. An offset of 30 seconds is added to timer SHLAPDIT to manage the links interruptions. 3. At least one PCMCONx must be connected to PORT_0. 4. The two elds of PCMCONx (x = 1..4) must be both specied or both skipped. 5. Port numbers specied in all the given PCMCONx (x = 1..4) attributes must be compatible with the BTS hardware version, as shown in the table below: INVALID_SVR The EXPSWV assigned to the BTSMis not handled by the software version of BSC. The EXPSWV is present on the BSC disk and the BTSE corresponding to the BTSM instance is aligned to it by the BSC. UNSUCCESSFUL_WRONG_PCMB_NUMBER Different PCMCONx must refer to different PCMB instances. UNSUCCESSFUL_WRONG_PORT_NUMBER Make reference to Application Guidelines n. 3, n. 4, n. 5. UNSUCCESSFUL_INVALID_ATTRIBUTES The values related to the First LAPD Overload Threshold (FLAPDOVTH) and the Second LAPD Overload Threshold (SLAPDOVTH) parameters must be set according to the following rule: FLAPDOVTH < SLAPDOVTH. Between the AbisTrafficHighThreshold and the AbisTrafficLowThreshold the following relationship must be verified: ABISTRFHITHR - ABISTRFLTHR >= 20. INVALID_SALES_UNIQUE_NAME If the SALUNAME is defined, it must be different from SALUNAME of the other BTSMs equipped. INCOMP_NESWLOAD_VS_MESSAGE PCMCON2 and/or PCMCON3 cannot be set at a value different fromNULL if the SWVersion running on the BTSMbelongs to BR6.0 release (see EXPSWV parameter description). The ABISHRACTTHR, ABISTRFHITHR and ABISTRFLTHR attributes must have NULL value if the SW Version running on the BTSM belongs to BR6.0 release (see EXPSWV parameter description), and a value different by <NULL> with SW Version >= BR7.0. The GASTRABISTH attribute must be set at NULL value if the SW Version running on the BTSM belongs to BR6.0 release, while it must be set at a value different fromNULL if the SWVersion running on the BTSM belongs to BR7.0 release (see EXPSWV parameter description) . UNSUCCESSFUL_VAR_OUT_OF_RANGE The thresholdIdleAbisSUfield of the GASTRABISTHattribute has to be lower or equal than the thresholdIdleAbisRU field and the thresholdIdleAbisHV field has to be lower or equal than the thresholdIdleAbisVH field. 240 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller The values PORT_2, PORT_4 or PORT_6 can be selected only if the object COSA is installed; with object COBA installed only the value PORT_0 can be selected. 6. The hardware object PORT_<n> corresponds to the object BPORT:<n>. At the BTSE side, the BPORT object must be previously created by means of the CREATE BPORT command. Example of Command Execution Create BTSM:NAME=BTSM:0,EXPSWV="01-00-01-01-04-04_95-03-01", SHLAPDIT=3,OMLAPDRT=4,EMT1=20,EMT2=30,SALUNAME="AD042S7449F", PCMCON0=PCMB_0-PORT_0,PCMCON1=PCMB_1-PORT_0, PCMCON2=PCMB_2-PORT_0,PCMCON3=PCMB_3-PORT_0, FLAPDOVLTH=10-5,SLAPDOVLTH=15-7,LAPDOVLT=<NULL>,TEI=5, LPDLMSAT=TRUE,ABISHRACTTHR=60,ABISTRFHITHR=90,ABISTRFLTHR=80, GASTRABISTH=10-20-15-25; DELETE BTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM DELETE BTSM Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a previously created BTSM. A consequence of this command is that also the corresponding BTSE object with the same instance number will no longer exist. The validity range of the object address "btsmn" can be found in Appendix A. System Responses: BTS PortNumber BS-21, BS-22 PORT_0, PORT_2 BS-20, BS-6x PORT_0, PORT_2 BS-82, BS-240XS PORT_0 BS-240/241, BS-4x PORT_0, PORT_2, PORT_4, PORT_6 BS-242 PORT_0, PORT_2, PORT_4, PORT_6 DELETE BTSM: NAME=BTSM:btsmn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 241 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Delete BTSM:NAME=BTSM:0; GET BTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM GET BTSM Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the specified BTSM instance. The validity range of the object address "btsmn" can be found in Appendix A. System Responses: UNSUCCESSFUL_INVALID_STATUS Before deleting a BTSM, the relative object instance must be in LOCKED state. UNSUCCESSFUL_SUBORDINATE_EQUIPPED All the BTS object instances associated to the BTSM object instance must be previously deleted. GET BTSM: NAME=BTSM:btsmn [,REQATTL=EXPSWV, SHLAPDIT, OMLAPDRT, EMT1, EMT2, SALUNAME, PCMCON0, PCMCON1, PCMCON2, PCMCON3, FLAPDOVLTH, SLAPDOVLTH, LAPDOVLT, TEI, LPDLMSAT, BTSEFAM, TOPOREL, ABISHRACTTHR, ABISTRFHITHR, ABISTRFLTHR, GASTRABISTH]; GET ACK: NAME: name EXPSWV: expectedSwVersion SHLAPDIT: shortLapdIntTimer OMLAPDRT omLapdRelTimer EMT1: emergencyTimer1 EMT2: mergencyTimer2 SALUNAME: salesUniqueName PCMCON0: pcmConnection0 PcmbNumber PortNumber PCMCON1: pcmConnection1 242 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get BTSM:NAME=BTSM:0,REQATTL=EXPSWV&SHLAPDIT&OMLAPDRT&EMT1& EMT2&SALUNAME&PCMCON0&PCMCON1&PCMCON2&PCMCON3& FLAPDOVLTH&SLAPDOVLTH&LAPDOVLT&TEI&LPDLMSAT&BTSEFAM& TOPOREL&ABISHRACTTHR&ABISTRFHITHR&ABISTRFLTHR&GASTRABISTH; PcmbNumber PortNumber PCMCON2: pcmConnection2 PcmbNumber PortNumber PCMCON3: pcmConnection3 PcmbNumber PortNumber FLAPDOVTH: firstLapdOverloadThreshold upperThreshold lowerThreshold SLAPDOVTH: secondLapdOverloadThreshold upperThreshold lowerThreshold LAPDOVLT: lapdOverloadTimer TEI: tei LPDLMSAT: lapdmLinkSatellited BTSEFAM: btseFamily TOPOREL: topologicalRelationship ABISHRACTTHR:abisHalfRateActivationThreshold ABISTRFHITHR:abisTrafficHighThreshold ABISTRFLTHR: abisTrafficLowThreshold GASTRABISTH: gprsAllocationStrategyAbisThresholds thresholdIdleAbisHV thresholdIdleAbisVH thresholdIdleAbisSU thresholdIdleAbisRU GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 243 Commands Base Station Controller CML:BSC GET BTSM BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM GET BTSM BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "btsmn" can be found in Appendix A. System Responses: GET BTSM BASICS: NAME=BTSM:btsmn; GET ACK: NAME: name EXPSWV: expectedSwVersion SHLAPDIT: shortLapdIntTimer OMLAPDRT omLapdRelTimer EMT1: emergencyTimer1 EMT2: mergencyTimer2 SALUNAME: salesUniqueName PCMCON0: pcmConnection0 PcmbNumber PortNumber PCMCON1: pcmConnection1 PcmbNumber PortNumber PCMCON2: pcmConnection2 PcmbNumber PortNumber PCMCON3: pcmConnection3 PcmbNumber PortNumber FLAPDOVTH: firstLapdOverloadThreshold upperThreshold lowerThreshold SLAPDOVTH: secondLapdOverloadThreshold upperThreshold lowerThreshold LAPDOVLT: lapdOverloadTimer TEI: tei LPDLMSAT: lapdmLinkSatellited BTSEFAM: btseFamily 244 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get BTSM BASICS:NAME=BTSM:0; GET BTSM STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM GET BTSM STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the BTSM object: Administrative State (AST) Operational State (OST) Usage State (UST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Unknown Status (UNK). The validity range of the object address "btsmn" can be found in Appendix A. TOPOREL: topologicalRelationship ABISHRACTTHR:abisHalfRateActivationThreshold ABISTRFHITHR:abisTrafficHighThreshold ABISTRFLTHR: abisTrafficLowThreshold GASTRABISTH: gprsAllocationStrategyAbisThresholds thresholdIdleAbisHV thresholdIdleAbisVH thresholdIdleAbisSU thresholdIdleAbisRU GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET BTSM STAT: NAME=BTSM:btsmn; A30808-X3247-L230-3-7619 245 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Get BTSM STAT:NAME=BTSM:0; GETINFO BTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM GETINFO BTSM Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The report complete indication. 2. The BTSE rack type. 3. The "OSU running" object and the "OSU version". 4. The Sales Unique Name of the BTSM. 5. Abis type (Static or Dynamic). 6. The BTSM state and statuses: AST, OST, AVS, PRS. 7. For each PCMB line supporting the BTSE: the number of pcm line; the AST, OST, AVS states and statuses; the BTSE port to which the pcm line is connected. 8. Subpools maps, per PCMB and LPDLM (order: subTsl0, subTsl1, subTsl2, subTsl3). 9. Total number of radio timeslots (CHANs) congured in the BTSM. 10. Total number of SUBTSLBs congured in the BTSM. 11. Number of full busy in service SUBTSLBs (both the subchannels used). 12. Number of half busy in service SUBTSLBs (only a subchannel used). 13. Number of out of service SUBTSLBs. 14. Number of in service fully idle SUBTSLBs. 15. The LMU Link Status. 16. For the BTSMand the BTSs: the administrative (AST) and operational (OST) states, the availability (AVS) and procedural (PRS) statuses. GET BTSM STAT ACK: GET BTSM STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETINFO BTSM: NAME=BTSM:btsmn; 246 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 17. For all the hardware managed objects: the administrative (AST) and operational (OST) states, the alarm (ALR), the availability (AVS), procedural (PRS) and the standby (STB) statuses. 18. The carrier capability (UNKNOWN, GSM, EDGE, FOUR_RX_DIV). The validity range of the object address "btsmn" can be found in Appendix A. System Responses GETINFO BTSM ACK: BSC_CONTROLLER -> LMT_LOCAL 11:41:14 22/03/1999 *** INFORMATION *** GET INFO REPORT: NAME = BTSM:1 REPORT COMPLETE: TRUE BTSE RACK TYPE: BS240XLSWB OSU: BTSMOSUSW 0 ESU RUNNING VERSION: 01-01-08-00-07-00_98-07-21 SALES UNIQUE NAME: VOGHERA ABIS TYPE: DYNAMIC ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE PROCEDURAL STATUS: NONE PCM LINES SUPPORTING BTSE: PCMB 12 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE BTSE PORT: PORT_2 PCMB 13 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE BTSE PORT: PORT_4 ABIS POOL: LPDLM: 0 PCMB: 12 TIMESLOT: 5 POOL MAP TS01:1111 TS02:0111 TS03:0011 TS04:0000 TS05:0000 TS06:1111 TS07:0011 TS08:1010 TS09:0011 TS10:0000 TS11:0011 TS12:0000 i If the LMT is connected in remote mode, it is not possible to execute this command. A30808-X3247-L230-3-7619 247 Commands Base Station Controller CML:BSC TS13:0000 TS14:0000 TS15:0000 TS16:0000 TS17:0000 TS18:0000 TS19:0000 TS20:0000 TS21:0000 TS22:0000 TS23:0000 TS24:0000 TS25:0000 TS26:0000 TS27:0000 TS28:0000 TS29:0000 TS30:1001 TS31:0011 LPDLM: 1 PCMB: 12 TIMESLOT: 13-0 POOL MAP TS01:0000 TS02:1000 TS03:1100 TS04:0000 TS05:0000 TS06:0000 TS07:1100 TS08:0000 TS09:0000 TS10:0000 TS11:0000 TS12:0000 TS13:0000 TS14:0000 TS15:0000 TS16:0000 TS17:0000 TS18:0000 TS19:0000 TS20:0000 TS21:0000 TS22:0000 TS23:0000 TS24:0000 TS25:0000 TS26:0000 TS27:0000 TS28:0000 TS29:1111 TS30:0000 TS31:1100 TOTAL NUMBER OF CONFIGURED CHANS: 100 TOTAL NUMBER OF CONFIGURED SUBTSLBS: 180 FULLY BUSY SUBTSLBS: 80 HALF BUSY SUBTSLBS: 10 OUT OF SERVICE SUBTSLBS: 30 FULLY IDLE SUBTSLBS: 60 LMU LINK ACTIVE: TRUE OBJECT ADMINISTRATIVE OPERATIONAL BTS 0 UNLOCKED ENABLED TRX 0 UNLOCKED ENABLED TRX 1 UNLOCKED ENABLED TRX 2 UNLOCKED ENABLED TRX 3 LOCKED ENABLED BTS 1 UNLOCKED ENABLED TRX 0 UNLOCKED ENABLED TRX 1 UNLOCKED ENABLED TRX 2 UNLOCKED ENABLED OBJECT AVAILABILITY PROCEDURAL BTS 0 DEPENDENCY REMOTE_DEPENDENCY NONE TRX 0 NONE NONE TRX 1 NONE NONE TRX 2 NONE NONE TRX 3 NONE NONE BTS 1 NONE NONE TRX 0 NONE NONE TRX 1 NONE NONE TRX 2 NONE NONE OBJECT ADMINISTRATIVE OPERATIONAL ALARM ACDCP 0-1 UNLOCKED ENABLED CLEARED 248 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller ACT 0-1 UNLOCKED ENABLED CLEARED BATTERY 0-1 UNLOCKED ENABLED CLEARED COBA 0-0 UNLOCKED ENABLED CLEARED COSA 0-1 UNLOCKED ENABLED CLEARED CU 0-2 UNLOCKED ENABLED CLEARED FANP1-0 UNLOCKED ENABLED CLEARED FTNFP 0-1 UNLOCKED ENABLED CLEARED FVSWRP 0-0 UNLOCKED ENABLED CLEARED DILNA 1-0 UNLOCKED ENABLED CLEARED DIDCTMA 1-1 UNLOCKED ENABLED CLEARED DUVSWR 0-1 UNLOCKED ENABLED CLEARED DULNA 1-1 UNLOCKED ENABLED CLEARED DUCTMA 0-0 UNLOCKED ENABLED CLEARED TMA 0-0 UNLOCKED ENABLED CLEARED BPORT 3 UNLOCKED ENABLED CLEARED XCONNECT-0 UNLOCKED ENABLED CLEARED ENVABTSE 0-2 UNLOCKED ENABLED CLEARED LMU 0 UNLOCKED ENABLED CLEARED SDUSEC 0-1 UNLOCKED ENABLED CLEARED SDUSUBSEC 0-1 UNLOCKED ENABLED CLEARED SDUTXSW 0-1 UNLOCKED ENABLED CLEARED SDULNA UNLOCKED ENABLED CLEARED ... ... OBJECT AVAILABILITY PROCEDURAL STANDBY ACDCP 0-1 NONE NONE PROVIDING_SERVICE ACT 0-1 NONE NONE NONE BATTERY 0-1 NONE NONE NONE COBA 0-0 NONE NONE NONE COSA 0-1 NONE NONE NONE CU 0-2 NONE NONE NONE FANP 1-0 NONE NONE NONE FTNFP 0-1 NONE NONE NONE FVSWRP 0-0 NONE NONE NONE DILNA 1-0 NONE NONE NONE DIDCTMA 1-1 NONE NONE NONE DUVSWR 0-1 NONE NONE NONE DULNA 1-1 NONE NONE NONE DUCTMA 0-0 NONE NONE NONE TMA 0-0 NONE NONE NONE BPORT 3 NONE NONE NONE XCONNECT 0 NONE NONE NONE ENVABTSE 0-2 NONE NONE NONE LMU 0 NONE NONE NONE ... ... SDUSEC 0-1 NONE NONE NONE SDUSUBSEC 0-1 NONE NONE NONE SDUTXSW 0-1 NONE NONE NONE SDULNA NONE NONE NONE OBJECT CAPABILITY A30808-X3247-L230-3-7619 249 Commands Base Station Controller CML:BSC ACDCP 0-1 ACT 0-1 BATTERY 0-1 COBA 0-0 COSA 0-1 CU 0-2 GSM, FOUR_RX_DIV FANP 1-0 FTNFP 0-1 FVSWRP 0-0 DILNA 1-0 DIDCTMA 1-1 DUVSWR 0-1 DULNA 1-1 DUCTMA 0-0 TMA 0-0 BPORT 3 XCONNECT 0 ENVABTSE 0-2 LMU 0 .. ... SDUSEC 0-1 SDUSUBSEC 0-1 SDUTXSW 0-1 SDULNA END OF REPORT REPORT COMPLETE: TRUE BTSE RACK TYPE: BS240XLSWB OSU: BTSMOSUSW 0 ESU RUNNING VERSION: 01-01-08-00-07-00_98-07-21 SALES UNIQUE NAME: VOGHERA ABIS TYPE: DYNAMIC ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE PROCEDURAL STATUS: NONE PCM LINES SUPPORTING BTSE: PCMB 12 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE BTSE PORT: PORT_2 PCMB 13 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE BTSE PORT: PORT_4 250 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller ABIS POOL: LPDLM: 0 PCMB: 12 TIMESLOT: 5 POOL MAP TS01:1111 TS02:0111 TS03:0011 TS04:0000 TS05:0000 TS06:1111 TS07:0011 TS08:1010 TS09:0011 TS10:0000 TS11:0011 TS12:0000 TS13:0000 TS14:0000 TS15:0000 TS16:0000 TS17:0000 TS18:0000 TS19:0000 TS20:0000 TS21:0000 TS22:0000 TS23:0000 TS24:0000 TS25:0000 TS26:0000 TS27:0000 TS28:0000 TS29:0000 TS30:1001 TS31:0011 LPDLM: 1 PCMB: 12 TIMESLOT: 13-0 POOL MAP TS01:0000 TS02:1000 TS03:1100 TS04:0000 TS05:0000 TS06:0000 TS07:1100 TS08:0000 TS09:0000 TS10:0000 TS11:0000 TS12:0000 TS13:0000 TS14:0000 TS15:0000 TS16:0000 TS17:0000 TS18:0000 TS19:0000 TS20:0000 TS21:0000 TS22:0000 TS23:0000 TS24:0000 TS25:0000 TS26:0000 TS27:0000 TS28:0000 TS29:1111 TS30:0000 TS31:1100 TOTAL NUMBER OF CONFIGURED CHANS: 100 TOTAL NUMBER OF CONFIGURED SUBTSLBS: 180 FULLY BUSY SUBTSLBS: 80 HALF BUSY SUBTSLBS: 10 OUT OF SERVICE SUBTSLBS: 30 FULLY IDLE SUBTSLBS: 60 LMU LINK ACTIVE: TRUE OBJECT ADMINISTRATIVE OPERATIONAL BTS 0 UNLOCKED ENABLED TRX 0 UNLOCKED ENABLED TRX 1 UNLOCKED ENABLED TRX 2 UNLOCKED ENABLED TRX 3 LOCKED ENABLED BTS 1 UNLOCKED ENABLED TRX 0 UNLOCKED ENABLED TRX 1 UNLOCKED ENABLED TRX 2 UNLOCKED ENABLED OBJECT AVAILABILITY PROCEDURAL BTS 0 DEPENDENCY REMOTE_DEPENDENCY NONE TRX 0 NONE NONE TRX 1 NONE NONE TRX 2 NONE NONE A30808-X3247-L230-3-7619 251 Commands Base Station Controller CML:BSC TRX 3 NONE NONE BTS 1 NONE NONE TRX 0 NONE NONE TRX 1 NONE NONE TRX 2 NONE NONE OBJECT ADMINISTRATIVE OPERATIONAL ALARM ACDCP 0-1 UNLOCKED ENABLED CLEARED ACT 0-1 UNLOCKED ENABLED CLEARED BATTERY 0-1 UNLOCKED ENABLED CLEARED COBA 0-0 UNLOCKED ENABLED CLEARED COSA 0-1 UNLOCKED ENABLED CLEARED CU 0-2 UNLOCKED ENABLED CLEARED FANP1-0 UNLOCKED ENABLED CLEARED FTNFP 0-1 UNLOCKED ENABLED CLEARED FVSWRP 0-0 UNLOCKED ENABLED CLEARED DILNA 1-0 UNLOCKED ENABLED CLEARED DIDCTMA 1-1 UNLOCKED ENABLED CLEARED DUVSWR 0-1 UNLOCKED ENABLED CLEARED DULNA 1-1 UNLOCKED ENABLED CLEARED DUCTMA 0-0 UNLOCKED ENABLED CLEARED TMA 0-0 UNLOCKED ENABLED CLEARED BPORT 3 UNLOCKED ENABLED CLEARED XCONNECT-0 UNLOCKED ENABLED CLEARED ENVABTSE 0-2 UNLOCKED ENABLED CLEARED LMU 0 UNLOCKED ENABLED CLEARED SDUSEC 0-1 UNLOCKED ENABLED CLEARED SDUSUBSEC 0-1 UNLOCKED ENABLED CLEARED SDUTXSW 0-1 UNLOCKED ENABLED CLEARED SDULNA UNLOCKED ENABLED CLEARED ... ... OBJECT AVAILABILITY PROCEDURAL STANDBY ACDCP 0-1 NONE NONE PROVIDING_SERVICE ACT 0-1 NONE NONE NONE BATTERY 0-1 NONE NONE NONE COBA 0-0 NONE NONE NONE COSA 0-1 NONE NONE NONE CU 0-2 NONE NONE NONE FANP 1-0 NONE NONE NONE FTNFP 0-1 NONE NONE NONE FVSWRP 0-0 NONE NONE NONE DILNA 1-0 NONE NONE NONE DIDCTMA 1-1 NONE NONE NONE DUVSWR 0-1 NONE NONE NONE DULNA 1-1 NONE NONE NONE DUCTMA 0-0 NONE NONE NONE TMA 0-0 NONE NONE NONE BPORT 3 NONE NONE NONE XCONNECT 0 NONE NONE NONE ENVABTSE 0-2 NONE NONE NONE 252 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller LMU 0 NONE NONE NONE ... ... SDUSEC 0-1 NONE NONE NONE SDUSUBSEC 0-1 NONE NONE NONE SDUTXSW 0-1 NONE NONE NONE SDULNA NONE NONE NONE OBJECT CAPABILITY ACDCP 0-1 ACT 0-1 BATTERY 0-1 COBA 0-0 COSA 0-1 CU 0-2 GSM, FOUR_RX_DIV FANP 1-0 FTNFP 0-1 FVSWRP 0-0 DILNA 1-0 DIDCTMA 1-1 DUVSWR 0-1 DULNA 1-1 DUCTMA 0-0 TMA 0-0 BPORT 3 XCONNECT 0 ENVABTSE 0-2 LMU 0 .. ... SDUSEC 0-1 SDUSUBSEC 0-1 SDUTXSW 0-1 SDULNA END OF REPORT Note on Poolmap: For each LPDLM a list of the SUBTSLBs assigned is reported. The map field is a 16 BYTEs where in the first BYTE the initial 4 bits are the sub-timeslots of the TSLB-0 (that is not displayed because it is the synchronous timeslot of PCM line). example: bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 subslot3 subslot2 subslot1 subslot0 Time slot 0 (sync) Time slot 1 Time slot 0 (sync) bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 1 1 0 1 0 0 0 0 Time slot 1 Time slot 0 (sync) A30808-X3247-L230-3-7619 253 Commands Base Station Controller CML:BSC the SUBTSLBs assigned to the LPDLM are SUBTSLB 1-0, SUBTSLB 1-2 and SUBTSLB 1-3 and are showed as: POOL MAP TS01:1101 TS02:....... Timeslot displayed can be either 24 or 31, depending on current configuration. GETINFO BTSM NACK: BSC_CONTROLLER -> LMT_LOCAL 16:24:45 2209/1998 *** RESPONSE TO JOB 1*** Get Info Report Nack BTSM: name = BTSM:1 nackCause = <nack cause> Application Guidelines: None. Example of Command Execution Getinfo BTSM:NAME=BTSM:0; GETRELATIONSHIP BTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMGETRELATIONSHIP BTSM Applicability: Phase 2. Visibility level 1. NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the system. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another GetInfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 GetInfo commands already in progress. GETRELATIONSHIP BTSM: NAME=BTSM:btsmn; 254 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of the all HMOs (Hardware Managed Object) supporting the FMO functionality. For the BTSM object the related HMOs are the following: LICD/LICDS, EPWR, PPLD, PWRD, MPCC, TDPC, MEMT, NTW, PPXL and BTSE instance (it is equal to the BTSM). The validity range of the object address "btsmn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship BTSM:NAME=BTSM:0; GETSUBO BTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC BTSM GETSUBO BTSM Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "btsmn" can be found in Appendix A. GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The object does not provide any relationship attribute. GETSUBO BTSM: NAME=BTSM:btsmn; A30808-X3247-L230-3-7619 255 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Getsubo BTSM:NAME=BTSM:0; LOCK BTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC BTSM LOCK BTSM Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state "Locked". The validity range of the object address "btsmn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). GETSUBO BTSM ACK: The output of the command can be composed by one or more pack with a maximumnumber of ten subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GETSUBO BTSM NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK BTSM: NAME=BTSM:btsmn; LOCK BTSM ACK: LOCK BTSM NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 256 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock BTSM:NAME=BTSM:0; SET BTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM SET BTSM Applicability: Phase 2. Visibility level 2. Command Description: This command modifies the BTSM parameters. The validity range of the object address "btsmn" can be found in Appendix A. System Responses: SET BTSM: NAME=BTSM:btsmn [,EXPSWV=] [,SHLAPDIT=] [,OMLAPDRT=] [,EMT1=] [,EMT2=] [,SALUNAME=] [,PCMCON0=] [,PCMCON1=] [,PCMCON2=] [,PCMCON3=] [,FLAPDOVLTH=] [,SLAPDOVLTH=] [,LAPDOVLT=] [,ABISHRACTTHR=] [,ABISTRFHITHR=] [,ABISTRFLTHR=] [,GASTRABISTH=]; SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. INVALID_SVR Make reference to Application Guidelines n. 1, n. 3, n. 5, n. 6, n. 7, n. 10, n. 11, n. 12, n. 13, n. 14, n. 15. UNSUCCESSFUL_WRONG_PCMB_NUMBER Different PCMCONx must refer to different PCMB instances. UNSUCCESSFUL_INVALID_ATTRIBUTES The values related to the First LAPD Overload Treshold (FLAPDOVTH) and the Second LAPD Overload Threshold (SLAPDOVTH) parameters must be set according to the following rule: FLAPDOVTH < SLAPDOVTH. A30808-X3247-L230-3-7619 257 Commands Base Station Controller CML:BSC Between the AbisTrafficHighThreshold and the AbisTrafficLowThreshold the following relationship must be verified: ABISTRFHITHR - ABISTRFLTHR >= 20. INVALID_SALES_UNIQUE_NAME If the SALUNAME is defined, it must be different from SALUNAME of the other BTSMs equipped. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The field pcmbNumber of the attributes PCMCONx (x = 1..4) must specify the PCMB carrying the LPDLM associated to the BTSM (there must be at least one LPDLM per each BTSM connected). The PCMB lines specified in all the given PCMCONx (x = 1..4) attributes must be already equipped. UNSUCCESSFUL_WRONG_PORT_NUMBER Make reference to Application Guidelines n. 4, n. 8, n. 9. INCOMP_NESWLOAD_VS_MESSAGE If BTSM SW version changes from a value belonging to BR7.0 release to a value belonging to BR6.0 release (see EXPSWV parameter description) the EBSPWRC and EMSPWRC attributes (see PWRC object) can not assume ADAPTIVE value. The ABISHRACTTHR, ABISTRFHITHR and ABISTRFLTHR attributes must have NULL value if the SW Version running on the BTSM belongs to BR6.0 release (see EXPSWV parameter description), and a value different by <NULL> with SW Version>= BR7.0 The EXPSWV attribute cannot be set at a value belonging to BR6.0 release (see the parameter description) if at least one subordinated PTPPKF object has the CSCH3CSCH4SUP attribute set at FALSE. In order to set EXPSWV at a value belonging to BR6.0 release (see the parameter description) the REPTYP attribute must be set at NORMAL in all the subordinated BTS objects. The REPTYP attribute can be set at ENHANCED value only if the SWVersion running on the superordinate BTSM belongs to BR7.0 release (see EXPSWV parameter description). The EXPSWV value can not be set at a value belonging to BR6.0 release (see the parameter description) if at least one of AMRHRCi attribute values is RATE_05. The software version cannot be changed froma value belonging to BR7.0 release to a value belonging to BR6.0 release (see EXPSWV parameter description) if any subordinate SWIBEAM object instance is equipped. In order to set EXPSWV at a value belonging to BR6.0 release (see the parameter description) the ELKADPT attribute must be set at FALSE in all the subordinated BTS objects. The EUSDCHO attribute (see BSC object) must be set at FALSE if the SW Version running on the BTSM belongs to BR6.0 release (see EXPSWV parameter description). The EUHO, EUBCHO, EUIMPHO, EUSCHO attributes (see HAND object) must be set at FALSE if the SWVersion running on the BTSM belongs to BR6.0 release (see EXPSWV parameter description). 258 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The EXPSWV assigned to the BTSM is not handled by the software version of the BSC. The EXPSWV is present on the BSC disk and the BTSE corresponding to the BTSM instance is aligned to it by the BSC. 2. An offset of 30 seconds is added to timer SHLAPDIT to manage the links interruptions. 3. The conguration is not consistent with the HW type of the BTSM; for hh and ii see the expected software version Cn-hh-vv-ii-ss-pp_yy-mm-dd coding: 4. The two elds of PCMCONx (x = 1..4) must be both specied or both skipped. 5. BS-242 cannot support GSMR as SYSID (BTS object). 6. BS-242 cannot support extended and concentric cells. The GASTRABISTH attribute must be set at NULL value if the SW Version running on the BTSM belongs to BR6.0 release, while it must be set at a value different from NULL if the SW Version running on the BTSM belongs to BR7.0 release (see EXPSWV parameter description) . To set the EXPSWV parameter so that the type of Abis changes fromdynamic to static, at least on SUBTSLB per CHAN must be available on PCMB connecting the BTSM. With the BSC running BR 7.0 software, and a downgrade on the BTSMsoftware has to be performed after the BTSMhas already been upgraded fromBR6.02 to BR7.0, it is only possible as long as the database for the BTSMhas not been modified. If the data- base has been modified on the BTSM, i.e. a newBTS is created, etc. while the BTSM is running BR7.0 code, then it is not possible to do the downgrade due to enhanced features being incorporated into the new BTSM, which is not compatible with the old software (BR6.02). To do the downgrade, one has to delete the BTS or reset the parameters in the BTSM to the orig- inal values. In other words, the database must be brought back to the original status before the upgrade occurred. UNSUCCESSFUL_INVALID_STATUS In order to set EXPSWV parameter the BTSMobject must be in LOCKED state. UNSUCCESSFUL_VAR_OUT_OF_RANGE The thresholdIdleAbisSU field of the GASTRABISTH attribute has to be lower or equal than the thresholdIdleAbisRU field and the thresholdIdleAbisHV field has to be lower or equal than the thresholdIdleAbisVH field. BS-2x, BS-6x BS-240/241, BS-240XL, BS-4x BS-242 BS-82 BS-240XS hh 01 04 04 04 04 ii 01 02 05 06 max TRX per BTSM 2, 6 24 24 8 6 max TRX per BTS 2, 6 24 12 8 2 max BTS per BTSM 2, 3 12 24 8 3 A30808-X3247-L230-3-7619 259 Commands Base Station Controller CML:BSC 7. BS-242 cannot support base band hopping (HOPMODE of BTS object). 8. Port numbers specied in all the given PCMCONx (x = 1..4) attributes must be compatible with the BTS hardware version, as shown in the table below: The values PORT_2, PORT_4 or PORT_6 can be selected only if the object COSA is installed; with object COBA installed only the value PORT_0 can be selected. The hardware object PORT_<n> corresponds to the object BPORT:<n>. 9. At least one PCMCONx must be connected to PORT_0. 10. BS-240XS cannot have SYSID value (see BTS object) equal to GSMDCS, GSM850PCS or GSM850DCS. 11. All the subordinate to a BS-240XS must have the same frequency range, no mixed congurations are allowed. The allowed congurations are: BB900 EXT900 F2ONLY PCS1900 DCS1800 GSMR GSM850. 12. If the BTSMis a BS-240XS, it is not possible to create for each BTSMa BTS number greater than 3. 13. If the BTSM is a BS-240XS, it is not possible to create for each subordinate BTS a TRX number greater than 2. 14. If the BTSMis a BS-240XS, it is not possible to create for each BTSMa TRX number greater than 6. 15. The AMRHRCi attributes can be set at value RATE_05 (7.40 kbit/s) only if the BTS HW Version is BTS plus. Example of Command Execution Set BTSM:NAME=BTSM:0,EXPSWV="01-00-01-01-04-04_95-03-01", SHLAPDIT=3,OMLAPDRT=4,EMT1=20,EMT2=30,SALUNAME="AD042S7449F", PCMCON0=PCMB_0 -PORT_0,PCMCON1=PCMB_1 -PORT_2, PCMCON2=PCMB_2-PORT_0,PCMCON3=PCMB_3-PORT_0, FLAPDOVLTH=15-10,SLAPDOVLTH=18-12,LAPDOVLT=4,ABISHRACTTHR=60, ABISTRFHITHR=90,ABISTRFLTHR=80,GASTRABISTH=10-20-15-25; SHUTDOWN BTSM BTS PortNumber BS-21, BS-22 PORT_0, PORT_2 BS-20, BS-6x PORT_0, PORT_2 BS-82, BS-240XS PORT_0 BS-240/241,BS-4x PORT_0, PORT_2, PORT_4, PORT_6 BS-242 PORT_0, PORT_2, PORT_4, PORT_6 SHUTDOWN BTSM: NAME=BTSM:btsmn; 260 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM SHUTDOWN BTSM Applicability: Phase 2. Visibility level 1. Command Description: This command allows the graceful transition of an object from the administrative state "Unlocked" to the administrative state "Locked" after the object has terminated its current activity. The BSS is able to force a mobile station to perform an intercell or inter-BSC HO by means of the O&M SHUTDOWN command. After the SHUTDOWN command is entered, the system tries to perform an intercell or inter-BSC HO per mobile station; in case of failure, a further attempt is performed every 30 seconds for the next 5 minutes period. If after the predefined period (5.5 minutes) the current activity is not terminated, the administrative state will be set at Locked. If one of the objects is still active or busy after the predefined period, ongoing calls will be dropped. The validity range of the object address "btsmn" can be found in Appendix A. System Responses: Application Guidelines: 1. If the operator has started too many shutdown commands, the system will display the SM TOO BUSY message. 2. Possible state transitions and timing: a) UNLOCKED -immediately-> SHUTTING DOWN ---------- immediately ----------> LOCKED b) UNLOCKED -immediately-> SHUTTING DOWN ---------- 5.5 minutes----------> LOCKED c) UNLOCKED -immediately-> SHUTTING DOWN ---------- after object went to idle state ----------> LOCKED The state changes described above show all the possible transitions when the shutdown command was performed. SHUTDOWN BTSM ACK: SHUTDOWN BTSM NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 261 Commands Base Station Controller CML:BSC The rst column of the table gives the situations which are affected by doing a shutdown of an object. Example of Command Execution Shutdown BTSM:NAME=BTSM:0; UNLOCK BTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM UNLOCK BTSM Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state "Unlocked". The validity range of the object address "btsmn" can be found in Appendix A. System Responses: Application Guidelines: Unlocking of BTSM causes a full BTS alignment. Example of Command Execution Unlock BTSM:NAME=BTSM:0; SITUATIONS TRANSITIONS FORCED/NOT FORCED idle object a) busy object but not released after the SHUTDOWN command b) busy object but released after the SHUTDOWN command c) UNLOCK BTSM: NAME=BTSM:btsmn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 262 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BTSMOSUSW The BTSMOSUSW (BTSM Operating Software Unit SW) is used to represent the operating software resource for BTSM; the OSUobjects are used to identify which ESUs (Executable Software Unit) are operational. GET BTSMOSUSW Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTSMOSUSW GET BTSMOSUSW Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of the parameters selected by the operator by means of the REQATTL correspondent list. Validity ranges of the object addresses btsmn and btsmosuswn can be found in Appendix A. System Responses: GET BTSMOSUSW NAME=BTSM:btsmn/BTSMOSUSW:btsmosuswn [,REQATTL=RUNESU, BCKUPESU, PH]; GET ACK: NAME: name RUNESU: runningESU BCKUPESU: backupESU PH: phase GET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another in progress. OBJECT_NOT_FOUND The referenced object does not exist. ABORT_BY_SYSTEM_NCK An internal system abort is occurred. A30808-X3247-L230-3-7619 263 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get BTSMOSUSW:NAME=BTSM:0/BTSMOSUSW:0, REQATTL=RUNESU& BCKUPESU&PH; GET BTSMOSUSW BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTSMOSUSW GET BTSMOSUSW BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all BTSMOSUSW parameters. Validity ranges of the object addresses btsmn and btsmosuswn can be found in Appendix A. System Responses: Application Guidelines: None. GET BTSMOSUSW BASICS: NAME=BTSM:btsmn/BTSMOSUSW:btsmosuswn; GET ACK: NAME: name RUNESU: runningESU BCKUPESU: backupESU PH: phase GET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another in progress. OBJECT_NOT_FOUND The referenced object does not exist. ABORT_BY_SYSTEM_NCK An internal system abort is occurred. 264 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Get BTSMOSUSW BASICS:NAME=BTSM:0/BTSMOSUSW:0; GETINFO BTSMOSUSW Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTSMOSUSW GETINFO BTSMOSUSW Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information about the running and the backup SW version (all together) for a BTSM network element: 1. For each NEYESUSW corresponding to runningESU attribute: NEYESUSW instance identier, User label associated, Version number, Operational state; 2. For each NEYESUSW corresponding to backupESU attribute: NEYESUSW instance identier, User label associated, Version number, Operational state; 3. Information about the load usage state. Validity ranges of the object addresses btsmn and btsmosuswn can be found in Appendix A. System Responses: GETINFO BTSMOSUSW ACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** INFORMATION *** GETINFO REPORT BTSMOSUSW: NAME = BTSMOSUSW:1 RUNNING ESU INSTANCE: 0 USER LABEL: 62BTSMASDAS0024 VERSION: 01-04-14-01-24-00_02-04-25 OPERATIONAL STATE: DISABLED BACKUP ESU INSTANCE: 0 GETINFOBTSMOSUSW NAME=BTSM:btsmn/BTSMOSUSW:btsmosuswn; A30808-X3247-L230-3-7619 265 Commands Base Station Controller CML:BSC USER LABEL: 62BTSMXX010024 VERSION: 01-04-14-01-24-00_02-04-25 OPERATIONAL STATE: ENABLED LOAD USAGE STATE: IDLE END OF REPORT GETINFO BTSMOSUSW NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack BTSMOSUSW: name = BTSMOSUSW:1 nackCause = <nack cause> Application Guidelines: None. Example of Command Execution Getinfo BTSMOSUSW:NAME=BTSM:0/BTSMOSUSW:1; SETRUNBACK BTSMOSUSW Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTSMOSUSW SETRUNBACK BTSMOSUSW Applicability: Phase 2. Visibility level 2. Command Description: This command allows to perform a "run-back" procedure: with this command the user sends an "Activate SW" message on A-bis link performing an activation of the new software on the involved BTS. During this phase the A-bis link falls down so the BTS GETINFO NACK: NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. SETRUNBACK BTSMOSUSW NAME=BTSM:btsmn/BTSMOSUSW:btsmosuswn; 266 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller goes out of order. When all the software (on BTS) is loaded the A-bis link restarts. Validity ranges of the object addresses "btsmn" and "btsmosuswn" can be found in Appendix A. System Responses: Application Guidelines: The OperationalState attribute of the specific BTSMESUSWmust be ENABLED. If the precondition is not satisfied and/or if the dbVersion required is not stored on BSC disk, then a specific error collector call is performed. Example of Command Execution Setrunback BTSMOSUSW:NAME=BTSM:0/BTSMOSUSW:0; SETRUNBACK ACK: SETRUNBACK NACK: NACK CAUSES: ABORT_BY_SYSTEM_NCK An internal system abort is occurred. OBJECT_NOT_FOUND The referenced object instance does not exist. INVALID_PARAMETER_NCK The involved NE attribute does not exist. The input parameter is out of range. OBJECT_ALREADY_IN_USE The command clashes with another in progress. INCONSISTENT_STATE_NCK NE activation time-out is expired. INITIALIZATION_IN_PROGRESS_NCK An initialization of the system is in progress. UNSUCCESSFUL_SYS_CALL A system function call is failed. UNSUCCESSFUL_OBJ_NOTEQUIPPED NE is not equipped. EXPECTED_SWVER_UNDEFINED_NCK Expected SW version is not defined for NE. PROCESSING_ERROR_NCK A function call (for example allocation of memory) fails. UNSUCCESSFUL_LINK_NOT_AVAIL The link with NE is not activated. DOWNLOAD_ALREADY_IN_PROGRESS_NCK A download of the same NE is already in progress. A30808-X3247-L230-3-7619 267 Commands Base Station Controller CML:BSC BTSMTD The BTSMTD object provides services to control the functionalities of one or more BTSTDs located at the same site. It performs all the operation and maintenance func- tions common to all transceivers. CREATE BTSMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD CREATE BTSMTD Applicability: Phase 2. Visibility level 2. Command Description: The object BTSMTD represents the O&M functionality related to a site and not to a specific BTSTD. A BTSMTD object is a logical grouping of one or more BTSTDs with common management needs. A consequence of this command is that also a BTSE object with the identical instance number will come into existence and can be queried e.g. for its attributes. The validity range of the object address "btsmtdn" can be found in Appendix A. System Responses: CREATE BTSMTD: NAME=BTSMTD:btsmtdn [,TDCUN=] ,EXPSWV= [,SHLAPDIT=] [,OMLAPDRT=] [,SALUNAME=] [,PCMCON0=] [,PCMCON1=] [,PCMCON2=] [,PCMCON3=] [,FLAPDOVLTH=] [,SLAPDOVLTH=] [,LAPDOVLT=] ,TEI= [,LPDLMSAT=] [,BTSPO=] [,ABISHRACTTHR=] CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The field pcmbNumber of the attributes PCMCONx (x = 1..4) must specify the PCMB carrying the LPDLMTD associated to the BTSMTD (there must be at least one LPDLMTD per each BTSMTD connected). The PCMB lines specified in all the given PCMCONx (x = 1..4) attributes must be already equipped. The field tdcun must refer to an equipped TDCU. 268 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. After the creation of the object the ADMINISTRATIVE state of this object is set at LOCKED. An UNLOCK command is required to put this object in service. 2. An offset of 30 seconds is added to timer SHLAPDIT to manage the links interruptions. 3. The hardware object PORT_<n> corresponds to the object BPORT:<n>. At the BTSE side, the BPORT object must be previously created by means of the CREATE BPORT command. Example of Command Execution Create BTSMTD:NAME=BTSMTD:0,TDCUN=0, EXPSWV="01-00-01-01-04-04_95-03-01",SHLAPDIT=3,OMLAPDRT=4, SALUNAME="AD042S7449F",PCMCON0=PCMB_0-PORT_0, PCMCON1=PCMB_1-PORT_0,PCMCON2=PCMB_2-PORT_0, PCMCON3=PCMB_3-PORT_0,FLAPDOVLTH=10-5,SLAPDOVLTH=15-7, LAPDOVLT=<NULL>,TEI=5,LPDLMSAT=TRUE,BTSPO=north-45-east-90, ABISHRACTTHR=60; INVALID_SVR The EXPSWV must be set and the BTS type must correspond to BTSC. UNSUCCESSFUL_WRONG_PCMB_NUMBER Different PCMCONx must refer to different PCMB instances. UNSUCCESSFUL_WRONG_PORT_NUMBER The two fields of PCMCONx (x=1, 2, 3) must be both specified or both skipped. The following values are accepted for the portNumber0 and porNumber1 fields: PORT_0, PORT_2. UNSUCCESSFUL_INVALID_ATTRIBUTES The values related to the First LAPD Overload Threshold (FLAPDOVTH) and the Second LAPD Overload Threshold (SLAPDOVTH) parameters must be set according to the following rule: FLAPDOVTH < SLAPDOVTH. INVALID_SALES_UNIQUE_NAME If the SALUNAME is defined, it must be different from SALUNAME of the other BTSMTDs equipped. UNSUCCESSFUL_VAR_OUT_OF_RANGE The maximum number of BTSMTD on a TDCU has been reached; no other BTSMTD can be equipped. INCOMP_NESWLOAD_VS_MESSAGE The attribute ABISHRACTTHR must be different by <NULL>.. A30808-X3247-L230-3-7619 269 Commands Base Station Controller CML:BSC DELETE BTSMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD DELETE BTSMTD Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a previously created BTSMTD. A consequence of this command is that also the corresponding BTSE object with the same instance number will no longer exist. The validity range of the object address "btsmtdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete BTSMTD:NAME=BTSMTD:0; DELETE BTSMTD: NAME=BTSMTD:btsmtdn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a BTSMTD, the relative object instance must be in LOCKED state. UNSUCCESSFUL_SUBORDINATE_EQUIPPED All the BTSTD object instances associated to the BTSMTD object instance must be previously deleted. 270 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET BTSMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD GET BTSMTD Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the specified BTSMTD instance. The validity range of the object address "btsmtdn" can be found in Appendix A. System Responses: GET BTSMTD: NAME=BTSMTD:btsmtdn [,REQATTL=TDCUN, EXPSWV, SHLAPDIT, OMLAPDRT, SALUNAME, PCMCON0, PCMCON1, PCMCON2, PCMCON3, FLAP- DOVLTH, SLAPDOVLTH, LAPDOVLT, TEI, LPDLMSAT, BTSEFAM, TOPOREL, BTSPO, ABISHRACTTHR]; GET ACK: NAME: name TDCUN tdcuNumber EXPSWV: expectedSwVersion SHLAPDIT: shortLapdIntTimer OMLAPDRT omLapdRelTimer SALUNAME: salesUniqueName PCMCON0: pcmConnection0 PcmbNumber PortNumber PCMCON1: pcmConnection1 PcmbNumber PortNumber PCMCON2: pcmConnection2 PcmbNumber PortNumber PCMCON3: pcmConnection3 PcmbNumber PortNumber FLAPDOVTH: firstLapdOverloadThreshold upperThreshold lowerThreshold SLAPDOVTH: secondLapdOverloadThreshold upperThreshold lowerThreshold A30808-X3247-L230-3-7619 271 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get BTSM:NAME=BTSM:0,REQATTL=TDCUN&EXPSWV&SHLAPDIT&OMLAPDRT&SA LUNAME&PCMCON0&PCMCON1&PCMCON2&PCMCON3& FLAPDOVLTH&SLAPDOVLTH&LAPDOVLT&TEI&LPDLMSAT&BTSEFAM& TOPOREL&BTSOP&ABISHRACTTHR; LAPDOVLT: lapdOverloadTimer TEI: tei LPDLMSAT: lapdmLinkSatellited BTSEFAM: btseFamily TOPOREL: topologicalRelationship BTSPO: bTSPosition signOfLatitude latitude signOfLongitude longitude ABISHRACTTHR:abisHalfRateActivationThreshold GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 272 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET BTSMTD BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD GET BTSMTD BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "btsmtdn" can be found in Appendix A. System Responses: GET BTSMTD BASICS: NAME=BTSMTD:btsmtdn; GET ACK: NAME: name TDCUN tdcuNumber EXPSWV: expectedSwVersion SHLAPDIT: shortLapdIntTimer OMLAPDRT omLapdRelTimer SALUNAME: salesUniqueName PCMCON0: pcmConnection0 PcmbNumber PortNumber PCMCON1: pcmConnection1 PcmbNumber PortNumber PCMCON2: pcmConnection2 PcmbNumber PortNumber PCMCON3: pcmConnection3 PcmbNumber PortNumber FLAPDOVTH: firstLapdOverloadThreshold upperThreshold lowerThreshold SLAPDOVTH: secondLapdOverloadThreshold upperThreshold lowerThreshold LAPDOVLT: lapdOverloadTimer TEI: tei LPDLMSAT: lapdmLinkSatellited BTSEFAM: btseFamily TOPOREL: topologicalRelationship A30808-X3247-L230-3-7619 273 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get BTSMTD BASICS:NAME=BTSMTD:0; GET BTSMTD STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD GET BTSMTD STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the BTSMTD object: Administrative State (AST) Operational State (OST) Usage State (UST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Unknown Status (UNK). The validity range of the object address "btsmtdn" can be found in Appendix A. System Responses: BTSPO: bTSPosition signOfLatitude latitude signOfLongitude longitude ABISHRACTTHR:abisHalfRateActivationThreshold GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET BTSMTD STAT: NAME=BTSMTD:btsmtdn; GET BTSMTD STAT ACK: GET BTSMTD STAT NACK: 274 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get BTSMTD STAT:NAME=BTSMTD:0; GETINFO BTSMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD GETINFO BTSMTD Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The report complete indication. 2. The BTSEC rack type. 3. The "OSU running" object and the "OSU version". 4. The Sales Unique Name of the BTSMTD. 5. The BTSMTD state and statuses: AST, OST, AVS, PRS. 6. For each PCMB line supporting the BTSC: the number of pcm line; the AST, OST, AVS states and statuses; the BTSE port to which the pcm line is connected. 7. For each LPDLMTD related to the BTSC: the number of pcm line; the timeslot and subtimeslot congured on the BTSMTD; subpools maps, per PCMB and LPDLMTD (order: subTsl3, subTsl2, subTsl1, subTsl0).. 8. Total number of radio timeslots (AIRTSTDs) congured in the BTSMTD. 9. Total number of SUBTSLBs congured in the BTSMTD. 10. Number of full busy in service SUBTSLBs (both the subchannels used). 11. Number of half busy in service SUBTSLBs (only a subchannel used). 12. Number of out of service SUBTSLBs. 13. Number of in service fully idle SUBTSLBs. 14. For the TRXTD and the BTSTDs: the administrative (AST) and operational (OST) states, the availability (AVS) and the procedural (PRS) statuses. NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETINFO BTSMTD: NAME=BTSMTD:btsmtdn; A30808-X3247-L230-3-7619 275 Commands Base Station Controller CML:BSC 15. For all the hardware managed objects: the administrative (AST) and operational (OST) states, the alarm (ALR), the availability (AVS), procedural (PRS) and the standby (STB) statuses. The validity range of the object address "btsmtdn" can be found in Appendix A. System Responses GETINFO BTSMTD ACK: BSC_CONTROLLER -> LMT_LOCAL 11:41:14 22/03/1999 *** INFORMATION *** GET INFO REPORT: NAME = BTSMTD:1 REPORT COMPLETE: TRUE BTSE RACK TYPE: NB430TS OSU: BTSMTDOSUSW 0 ESU RUNNING VERSION: 01-01-08-00-07-00_98-07-21 SALES UNIQUE NAME: VOGHERA ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE PROCEDURAL STATUS: NONE PCM LINES SUPPORTING BTSC: PCMB 12 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE BTSE PORT: PORT_2 PCMB 13 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE BTSE PORT: PORT_4 ABIS POOL: LPDLM: 0 PCMB: 12 TIMESLOT: 5 POOL MAP TS01:1111 TS02:0111 TS03:0011 TS04:0000 TS05:0000 TS06:1111 TS07:0011 TS08:1010 TS09:0011 TS10:0000 TS11:0011 TS12:0000 TS13:0000 TS14:0000 TS15:0000 TS16:0000 TS17:0000 TS18:0000 TS19:0000 TS20:0000 i If the LMT is connected in remote mode, it is not possible to execute this command. 276 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TS21:0000 TS22:0000 TS23:0000 TS24:0000 TS25:0000 TS26:0000 TS27:0000 TS28:0000 TS29:0000 TS30:1001 TS31:0011 LPDLM: 1 PCMB: 12 TIMESLOT: 13-0 POOL MAP TS01:0000 TS02:1000 TS03:1100 TS04:0000 TS05:0000 TS06:0000 TS07:1100 TS08:0000 TS09:0000 TS10:0000 TS11:0000 TS12:0000 TS13:0000 TS14:0000 TS15:0000 TS16:0000 TS17:0000 TS18:0000 TS19:0000 TS20:0000 TS21:0000 TS22:0000 TS23:0000 TS24:0000 TS25:0000 TS26:0000 TS27:0000 TS28:0000 TS29:1111 TS30:0000 TS31:1100 TOTAL NUMBER OF CONFIGURED AIRTSTD: 180 TOTAL NUMBER OF CONFIGURED SUBTSLBS: 180 FULLY BUSY SUBTSLBS: 80 HALF BUSY SUBTSLBS: 10 OUT OF SERVICE SUBTSLBS: 30 FULLY IDLE SUBTSLBS: 60 OBJECT ADMINISTRATIVE OPERATIONAL BTSTD 0 UNLOCKED ENABLED TRXTD 1 UNLOCKED ENABLED TRXTD 2 UNLOCKED ENABLED BTSTD 1 UNLOCKED ENABLED TRXTD 0 UNLOCKED ENABLED TRXTD 1 UNLOCKED ENABLED TRXTD 2 UNLOCKED ENABLED OBJECT AVAILABILITY PROCEDURAL BTSTD 0 DEPENDENCY REMOTE_DEPENDENCY NONE TRXTD 1 NONE NONE TRXTD 2 NONE NONE BTSTD 1 NONE NONE TRXTD 1 NONE NONE TRXTD 2 NONE NONE .. ....... OBJECT ADMINISTRATIVE OPERATIONAL ALARM AVAILABILITY ACDCP 0-1 UNLOCKED ENABLED CLEARED NONE ACT 0-1 UNLOCKED ENABLED CLEARED NONE ANTENNA 0-0 UNLOCKED ENABLED CLEARED NONE BATTERY 0-1 UNLOCKED ENABLED CLEARED NONE COBA 0-0 UNLOCKED ENABLED CLEARED NONE FANP 1-0 UNLOCKED ENABLED CLEARED NONE A30808-X3247-L230-3-7619 277 Commands Base Station Controller CML:BSC GPS 0-0 UNLOCKED ENABLED CLEARED NONE LNA 0-1 UNLOCKED ENABLED CLEARED NONE ENVABTSC 0-2 UNLOCKED ENABLED CLEARED NONE OBJECT PROCEDURAL STANDBY ACDCP 0-1 NONE NONE ACT 0-1 NONE NONE ANTENNA 0-0 NONE NONE BATTERY 0-1 NONE NONE COBA 0-0 NONE NONE FANP 1-0 NONE NONE GPS 0-0 NONE NONE LNA 0-1 NONE NONE ENVABTSC 0-2 NONE NONE END OF REPORT Note on Poolmap: For each LPDLMTD a list of the SUBTSLBs assigned is reported. The map field is a 16 BYTEs where in the first BYTE the initial 4 bits are the sub-timeslots of the TSLB-0 (that is not displayed because it is the synchronous timeslot of PCM line). example: the SUBTSLBs assigned to the LPDLMTD are SUBTSLB 1-0, SUBTSLB 1-2 and SUBTSLB 1-3 and are showed as: POOL MAP TS01:1101 TS02:....... Timeslot displayed can be either 24 or 31, depending on current configuration. GETINFO BTSMTD NACK: BSC_CONTROLLER -> LMT_LOCAL 16:24:45 2209/1998 *** RESPONSE TO JOB 1*** Get Info Report Nack BTSMTD: bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 subslot3 subslot2 subslot1 subslot0 Time slot 0 (sync) Time slot 1 Time slot 0 (sync) bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 1 1 0 1 0 0 0 0 Time slot 1 Time slot 0 (sync) 278 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller name = BTSMTD:1 nackCause = <nack cause> Application Guidelines: None. Example of Command Execution Getinfo BTSMTD:NAME=BTSMTD:0; GETRELATIONSHIP BTSMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD GETRELATIONSHIP BTSMTD Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of the all HMOs (Hardware Managed Object) supporting the FMO functionality. For the BTSMTD object the related HMOs are the following: LICD/LICDS, EPWR, PWRD, MPCC, TDPC, MEMT, NTW, PPXT and BTSE instance (it is equal to the BTSMTD). The validity range of the object address "btsmtdn" can be found in Appendix A. System Responses: NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the system. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another GetInfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 GetInfo commands already in progress. GETRELATIONSHIP BTSMTD: NAME=BTSMTD:btsmtdn; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: A30808-X3247-L230-3-7619 279 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Getrelationship BTSMTD:NAME=BTSMTD:0; GETSUBO BTSMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC BTSMTD GETSUBO BTSMTD Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "btsmtdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo BTSMTD:NAME=BTSMTD:0; NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The object does not provide any relationship attribute. GETSUBO BTSMTD: NAME=BTSMTD:btsmtdn; GETSUBO BTSMTD ACK: The output of the command can be composed by one or more pack with a maximumnumber of ten subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GETSUBO BTSMTD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 280 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller LOCK BTSMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC BTSMTD LOCK BTSMTD Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state "Locked". The validity range of the object address "btsmtdn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock BTSMTD:NAME=BTSMTD:0; SET BTSMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD SET BTSMTD LOCK BTSMTD: NAME=BTSMTD:btsmtdn; LOCK BTSMTD ACK: LOCK BTSMTD NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SET BTSMTD: NAME=BTSMTD:btsmtdn ,EXPSWV= [,SHLAPDIT=] [,OMLAPDRT=] [,SALUNAME=] [,PCMCON0=] [,PCMCON1=] [,PCMCON2=] [,PCMCON3=] [,FLAP- DOVLTH=] [,SLAPDOVLTH=] [,LAPDOVLT=] [,BTSPO=] [,ABISHRACTTHR=]; A30808-X3247-L230-3-7619 281 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 2. Command Description: This command modifies the BTSMTD parameters. The validity range of the object address "btsmtdn" can be found in Appendix A. System Responses: SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. INVALID_SVR The expected Sw version must be set and the BTS type must correspond to BTSC. UNSUCCESSFUL_WRONG_PCMB_NUMBER Different PCMCONx must refer to different PCMB instances. UNSUCCESSFUL_INVALID_ATTRIBUTES The values related to the First LAPD Overload Treshold (FLAPDOVTH) and the Second LAPD Overload Threshold (SLAPDOVTH) parameters must be set according to the following rule: FLAPDOVTH < SLAPDOVTH. INVALID_SALES_UNIQUE_NAME If the SALUNAME is defined, it must be different from SALUNAME of the other BTSMs equipped. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The field pcmbNumber of the attributes PCMCONx (x = 1..4) must specify the PCMB carrying the LPDLMTD associated to the BTSMTD (there must be at least one LPDLMTD per each BTSMTD connected). The PCMB lines specified in all the given PCMCONx (x = 1..4) attributes must be already equipped. UNSUCCESSFUL_WRONG_PORT_NUMBER The two fields of PCMCONx (x=1, 2, 3) must be both specified or both skipped. The following values are accepted for the portNumber0 and porNumber1 fields: PORT_0, PORT_2. UNSUCCESSFUL_INVALID_STATUS In order to set EXPSWV parameter the BTSMTDobject must be in LOCKED state. UNSUCCESSFUL_VAR_OUT_OF_RANGE The thresholdIdleAbisSU field of the GASTRABISTH attribute has to be lower or equal than the thresholdIdleAbisRU field and the thresholdIdleAbisHV field has to be lower or equal than the thresholdIdleAbisVH field. 282 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: An offset of 30 seconds is added to timer SHLAPDIT to manage the links interruptions. Example of Command Execution Set BTSMTD:NAME=BTSMTD:0,EXPSWV="01-00-01-01-04-04_95-03-01", SHLAPDIT=3,OMLAPDRT=4,SALUNAME="AD042S7449F", PCMCON0=PCMB_0-PORT_0,PCMCON1=PCMB_1-PORT_0, PCMCON2=PCMB_2-PORT_0,PCMCON3=PCMB_3-PORT_0, FLAPDOVLTH=10-5,SLAPDOVLTH=15-7,LAPDOVLT=<NULL>, BTSPO=north-45-east-90,ABISHRACTTHR=60; SHUTDOWN BTSMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD SHUTDOWN BTSMTD Applicability: Phase 2. Visibility level 1. Command Description: This command allows the graceful transition of an object from the administrative state "Unlocked" to the administrative state "Locked" after the object has terminated its current activity. The BSS is able to force a mobile station to perform an intercell or inter-BSC HO by means of the O&M SHUTDOWN command. After the SHUTDOWN command is entered, the system tries to perform an intercell or inter-BSC HO per mobile station; in case of failure, a further attempt is performed every 30 seconds for the next 5 minutes period. If after the predefined period (5.5 minutes) the current activity is not terminated, the administrative state will be set at Locked. If one of the objects is still active or busy after the predefined period, ongoing calls will be dropped. The validity range of the object address "btsmn" can be found in Appendix A. UNSUCCESSFUL_SUBORDINATE_EQUIPPED When PCMCON0, PCMCON1, PCMCON2 or PCMCON3 attributes are modified, no connection must exist under the orig- inal PCMB link. INCOMP_NESWLOAD_VS_MESSAGE The attribute ABISHRACTTHR must be different by <NULL>.. SHUTDOWN BTSMTD: NAME=BTSMTD:btsmtdn; A30808-X3247-L230-3-7619 283 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: 1. If the operator has started too many shutdown commands, the system will display the SM TOO BUSY message. 2. Possible state transitions and timing: a) UNLOCKED -immediately-> SHUTTING DOWN ---------- immediately ----------> LOCKED b) UNLOCKED -immediately-> SHUTTING DOWN ---------- 5.5 minutes----------> LOCKED c) UNLOCKED -immediately-> SHUTTING DOWN ---------- after object went to idle state ----------> LOCKED The state changes described above show all the possible transitions when the shutdown command was performed. The rst column of the table gives the situations which are affected by doing a shutdown of an object. Example of Command Execution Shutdown BTSMTD:NAME=BTSMTD:0; UNLOCK BTSMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD UNLOCK BTSMTD Applicability: Phase 2. Visibility level 1. SHUTDOWN BTSMTD ACK: SHUTDOWN BTSMTD NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SITUATIONS TRANSITIONS FORCED/NOT FORCED idle object a) busy object but not released after the SHUTDOWN command b) busy object but released after the SHUTDOWN command c) UNLOCK BTSMTD: NAME=BTSMTD:btsmtdn; 284 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command allows to set an object at the administrative state "Unlocked". The validity range of the object address "btsmtdn" can be found in Appendix A. System Responses: Application Guidelines: Unlocking of BTSMTD causes a full BTSTD alignment. Example of Command Execution Unlock BTSMTD:NAME=BTSMTD:0; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 285 Commands Base Station Controller CML:BSC BTSMTDOSUSW The BTSMTDOSUSW(BTSMTD Operating Software Unit SW) is used to represent the operating software resource for BTSMTD; the OSU objects are used to identify which ESUs (Executable Software Unit) are operational. GET BTSMTDOSUSW Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSMTDOSUSW GET BTSMTDOSUSW Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of the parameters selected by the operator by means of the REQATTL correspondent list. Validity ranges of the object addresses btsmtdn and btsmtdosuswn can be found in Appendix A. System Responses: GET BTSMTDOSUSW NAME=BTSMTD:btsmtdn/BTSMTDOSUSW:btsmt- dosuswn [,REQATTL=RUNESU, BCKUPESU, PH]; GET ACK: NAME: name RUNESU: runningESU BCKUPESU: backupESU PH: phase GET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another in progress. OBJECT_NOT_FOUND The referenced object does not exist. ABORT_BY_SYSTEM_NCK An internal system abort is occurred. 286 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get BTSMTDOSUSW:NAME=BTSMTD:0/BTSMTDOSUSW:0, REQATTL=RUNESU& BCKUPESU&PH; GET BTSMTDOSUSW BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSMTDOSUSW GET BTSMTDOSUSW BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all BTSMTDOSUSW parameters. Validity ranges of the object addresses btsmtdn and btsmtdosuswn can be found in Appendix A. System Responses: GET BTSMTDOSUSW BASICS: NAME=BTSMTD:btsmtdn/BTSMTDOSUSW:btsmt- dosuswn; GET ACK: NAME: name RUNESU: runningESU BCKUPESU: backupESU PH: phase GET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another in progress. OBJECT_NOT_FOUND The referenced object does not exist. ABORT_BY_SYSTEM_NCK An internal system abort is occurred. A30808-X3247-L230-3-7619 287 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get BTSMTDOSUSW BASICS:NAME=BTSMTD:0/BTSMTDOSUSW:0; GETINFO BTSMTDOSUSW Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSMTDOSUSW GETINFO BTSMTDOSUSW Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information about the running and the backup SW version (all together) for a BTSMTD network element: 1. For each NEYESUSW corresponding to runningESU attribute: NEYESUSW instance identier, User label associated, Version number, Operational state; 2. For each NEYESUSW corresponding to backupESU attribute: NEYESUSW instance identier, User label associated, Version number, Operational state; 3. Information about the load usage state. Validity ranges of the object addresses btsmtdn and btsmtdosuswn can be found in Appendix A. System Responses: GETINFO BTSMTDOSUSW ACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** INFORMATION *** GETINFO REPORT BTSMTDOSUSW: NAME = BTSMTDOSUSW:1 RUNNING ESU INSTANCE: 0 USER LABEL: 62BTSMTDASDAS0024 GETINFO BTSMTDOSUSW NAME=BTSMTD:btsmtdn/BTSMTDOSUSW:btsmtdosuswn; 288 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller VERSION: 01-04-14-01-24-00_02-04-25 OPERATIONAL STATE: DISABLED BACKUP ESU INSTANCE: 0 USER LABEL: 62BTSMTDXX010024 VERSION: 01-04-14-01-24-00_02-04-25 OPERATIONAL STATE: ENABLED LOAD USAGE STATE: IDLE END OF REPORT GETINFO BTSMTDOSUSW NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack BTSMTDOSUSW: name = BTSMTDOSUSW:1 nackCause = <nack cause> Application Guidelines: None. Example of Command Execution Getinfo BTSMTDOSUSW:NAME=BTSMTD:0/BTSMTDOSUSW:1; SETRUNBACK BTSMTDOSUSW Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSMTDOSUSW SETRUNBACK BTSMTDOSUSW Applicability: Phase 2. Visibility level 2. GETINFO NACK: NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. SETRUNBACK BTSMTDOSUSW NAME=BTSMTD:btsmtdn/BTSMTDOSUSW:btsmtdosuswn; A30808-X3247-L230-3-7619 289 Commands Base Station Controller CML:BSC Command Description: This command allows to perform a "run-back" procedure: load of the BTSMTDOSUSW object from OSUSW backup ESU object. Validity ranges of the object addresses "btsmtdn" and "btsmtdosuswn" can be found in Appendix A. System Responses: Application Guidelines: The OperationalState attribute of the specific BTSMESUSWmust be ENABLED. If the precondition is not satisfied and/or if the dbVersion required is not stored on BSC disk, then a specific error collector call is performed. Example of Command Execution Setrunback BTSMTDOSUSW:NAME=BTSMTD:0/BTSMTDOSUSW:0; SETRUNBACK ACK: SETRUNBACK NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. ABORT_BY_SYSTEM_NCK An internal system abort is occurred. OBJECT_NOT_FOUND The referenced object does not exist. INVALID_PARAMETER_NCK The involved NE attribute does not exist. The input parameter is out of range. OBJECT_ALREADY_IN_USE The command clashes with another in progress. INCONSISTENT_STATE_NCK NE activation time-out is expired. INITIALIZATION_IN_PROGRESS_NCK An initialization of the system is in progress. UNSUCCESSFUL_SYS_CALL A system function call is failed. UNSUCCESSFUL_OBJ_NOTEQUIPPED NE is not equipped. EXPECTED_SWVER_UNDEFINED_NCK Expected SW version is not defined for NE. PROCESSING_ERROR_NCK A function call (for example allocation of memory) fails. UNSUCCESSFUL_LINK_NOT_AVAIL The link with NE is not activated. DOWNLOAD_ALREADY_IN_PROGRESS_NCK A download of the same NE is already in progress. 290 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BTSTD The BTSTD object locates a TD-SCDMA cell connected to BSC. It logically represents all the information related to the cell and to its configuration. CREATE BTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD CREATE BTSTD CREATE BTSTD NAME=BTSMTD:btsmtdn/BTSTD:btstdn, [BCCHFREQTD=] [,CALLF<nn>TD=] [,PCCCHLDI=] [,RACHBT=] [,RACHLAS=] [,TCCCHLDI=] [,NF1=] [,CELLRESH=] [,RXLEVAMITD=] [,CBQ=] [,CRESOFF=] [,TEMPOFF=] [,PENTIME=] [,NMULBAC=], BSIDC= [,RDLNKTO=] , CELLGLID= [,EBEAMFTX=] [,TXPWRDLPTS=] [,MARXPP=] [,FBFTH=] [,SLOWBFTH=] [,THTXBF=] [,MANBFEVTX=] [,NREPIEV=] [,NREPEV=] [,THPWREV=] [,EBFONPFACH=] [,THPP=] [,AVPSD- MEAS=] [,AVPNSME=] [,NFLPD=] [,CNTTHPYUL=] [,PKAVDTH=] [,PKSDDTH=] [,CNTTH=] [,PKSID- EDTH=] [,PKSDDCOLLTH=] [,ULSS=] [,ULSRP=] ,MATXDLTSX= [,PWRPFACH=] [,SNRIMPRETH=] , PRIDLFG=, INTTHDL=, INTTHUL=, INTULAVP=, INTDLAVP=, PRIUDPUL=, PRIUDPDL= [,ULSIR- ACST=] [,ULDCAST=] [,DLDCAST=] [,FACCHQTD=] [,SCCPCHDESC=] [,UPPTSRXPL=] [,SSUPPTS=] [,MANOUSRTS=] ,PRACHDESC=, PFACHDESC= [,UETSCPMA=] [,PREFPRIO=] [,MIULPRI=] [, MIDLPRI=] [,MIULPRIHO=] [,MIDLPRIHO=] [,TSPRILVBOUN=] , TDNCCPERMI= [,PLMNP=] [,DLBFTH=] [,DONDLPCTH=] [,DONULPCTH=] [,DONULSCTH=] [,DLSIRACST=] [,EEXCDIST=] [,PKAVDRELTH=] [,SYNC1LDAVS=] [,EXCDISTTD=] , MASONLYC=, HREFRLDTH= ,PRIULFG= [,RXPWRDES=] [,TXPPCCPCH=] , MARINTDL= [,MATXULTSX=] , PCCPCHDESC= [,BTSHSCSD=] [,MACRADIUS=] , PATHLSLOPE= [,BCIDLERESTH=] [,CPPFAC=] [,EXTMEPROC- CLER=] [,MODLUPDMIPER=] [,PKNWK=] [,LCBM0=] [,LCBM1=] [,LCBM2=] [,LCBM3=] [,NFRAMEPG=] [,MARACHTRANS=][,TXINT=] [,MASY1RETS=] [,T3126=] [,UETXPMACC=] [,CELLBARR=] [,CREALL=] [,NALLWACC=] [,SMSCBUSE=] [,IMSIATDT=] [,T3212=] [,EARCLM=] [,EC=] [,T200TD=] [,TSYNC=] [,TSYNCDL=] [,TSYNCUL=,] [,TSYNCR=] [,TTRAU=,] [,T3101=] [,T3109=] [,T3111=] [,T3208=] [ENANCD=] [,NCDP1=] [,NCDP2=] [,DWPTSCANAINTEX]; A30808-X3247-L230-3-7619 291 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 2. Command Description: This command sets the configuration of a cell specifying global parameters necessary for the creation. The attributes within this object describe the basic properties of a BTSTD which are not related to the Common Control Channels. All the other parameters will assume their default values if no other command is submitted. Moreover, this command implicitly creates the PWRCTD and HANDTD Managed Objects. Validity ranges of the object addresses "btsmtdn" and "btstdn" can be found in Appendix A. System Responses: CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The BTSMTD instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. For more details see Application Guidelines n. 3, n. 5, n. 6, n. 7, n.8, n.12, n.13, n.14, n.15, n.16, n.17. UNSUCCESSFUL_CELL_GLOB_ID All the fields of cellGlobalIdentity must be set in the following combination: MCC, MNC, LAC, CI, where: Location Area Identity (LAI) = MCC + MNC + LAC; Cell Global Identity = LAI + CI. The CELLGLID cannot be equal to the CELLGLID assigned to another BTS, TGTBTS, BTSTD, or TGTBTSTD. UNSUCCESSFUL_EQUAL_FREQ BCCHFREQTD, CALLF01TDand CALLF02TDattributes cannot assume the same values. UNSUCCESSFUL_OVERLAP_BAND The distance between any pair of frequency attributes must be at least 1.6 MHz. UNSUCCESSFUL_SUM_OF_BLOCKS_NOT_ALLOWED On P-CCPCH the sum of blocks for BCCH, AGCH, CBCH, Reserved Blocks (Blk_AGCH+Blk_RES+ Blk_CBCH + Blk_BCCH) must be lower than 9. 292 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The management of the BTSTDmanaged object is split into the management of ve attribute groups: 2. The creation of a BTSTD implies the implicit creation of the HANDTD and PWRCTD Managed Objects. 3. Three attributes in the BTSTDManaged Object are formatted in digits; the attributes are: the MobileCountryCode (MCC) and the MobileNetworkCode (MNC) contained in the CellGlobalId (CELLGLID); the bSIdentityCodeTD (BSIDC); 4. After the creation of the object, the ADMINISTRATIVE state of this object is set at LOCKED. An UNLOCK command is required to put this object in service. 5. The HSCSD service can be activated in the cell (BTSHSCSD = TRUE) only if the HSCSD service is activated at BSC side (ENHSCSD attribute of BSC set at TRUE). On all configured S-CCPCH the sum of blocks for AGCH and reserved Blocks (Blk_AGCH + Blk_RES) must be 12 BCCFTD_AND_BSIDC_BELONG_TO_ANOTHER_CELL The pair BCCHFREQTD - BSIDC must be different fromthe pair BCCHFREQTD - BSIDC of an existing cell or TGTBTSTD. BASIC BTSTD basic group CCCH BTSTD CCCH configuration group OPTIONS BTSTD options group TIMER BTSTD timer group CELLGLID = MCC-MNC-LAC-CI Note that MCC = D1D2D3 MNC = D1D2D3 Dx means digit (only numerical characters shall be used; for numbers from 0 to 9 it must be entered one digit). In fact 9 is different from 09. For MCC all digits are mandatory while for MNC only D1 is mandatory. BSIDC = D1D2 Dx means digit (only numerical characters 0..7 shall be used) Note that D1 is the NetworkColourCode (NCC) and D2 is the BTSTDColourCode (BCC) This attributes are stored in the system in their decimal representation (which is the input format) but it is necessary to check the range of each digit: MCC, MNC 0 =< Dx =< 9 BSIDC 0 =< Dx =< 7 Do not configure cells without giving a value to the parameter Cell Identifier (CI) of the Cell Global Identifier attribute belonging to the BTSTD BASICS group because such cells are not handled by the system. A30808-X3247-L230-3-7619 293 Commands Base Station Controller CML:BSC 6. If the excessive distance is enabled (EEXCDIST = TRUE) the value assigned to the attribute EXCDISTTD must be greater than the value assigned to the distance handover threshold hoThresholdMsRangeMax (attribute HOTMSRMTD of HANDTD object) 7. For the attribute NCDP2, the TimerNoCall2 eld can be set only if the StarTime2 eld is different from NOTUSED. 8. If the second time-frame is congured by the NCDP2 setting, the StartTime2 value must be greater than the StartTime1 eld of NCDP1 attribute. If the second time-frame is congured by the NCDP2 setting, the following congu- ration rule must be satised: 9. LCBMx attributes can be set at a value different from NULL only if no CBCL instances have been already equipped. 10. The timers TSYNC and TTRAU must be set longer than ALARMT2 (see LICD object). The timers TSYNC and TTRAU must be set longer than BSCT10 (BSC object) and BSCT8 (BSC object). This is to ensure that a signalling failure (BSCT8 and BSCT10) is detected before a transcoder failure (TSYNC and TTRAU). The attribute TSYNC should be equal to TTRAU attribute. 11. In order to enable the HSCSDservice, the EARCLMattribute must be previously set at TRUE. 12. The following relationship between the MANOUSRTS attribute and the TSC eld of PRACHDESC, PFACHDESC, SCCPCHDESC parameters must be fullled: TSC <= MANOUSRTS - 1 13. For all congured PRACHDESC, if the timeslot elds are equal, then: the TSC elds must be different; the SC elds must be different; the SC elds must belong to the same range ([0..15] or [16..23], which indicates SF = 16 or SF = 8 respectively). 14. For all congured PFACHDESC, if the timeslot elds are equal, the TSC elds must be different. 15. For all congured SCCPCHDESC, if the timeslot elds are equal, the TSC elds must be different. 16. For all congured PFACHDESC and SCCPCHDESC, if any timeslot eld of PFACH- DESCis equal to any timeslot eld of SCCPCHDESC, the TSCeld of PFACHDESC must be different from the TSC eld of SCCPCHDESC. 17. Blk_AGCHeld must be always congured: either on only one S-CCPCHcongured or on PCCPCH. Congured means blk_AGCH different from 0. Example of Command Execution Create BTSTD:NAME=BTSMTD:0/BTSTD:0,BCCHFREQTD=60, CALLF01TD=10, PCCCHLDI=255,RACHBT=27,RACHLAS=204,TCCCHLDI=100,NF1=127, CELLRESH=2,RXLEVAMITD=6,CBQ=0,CRESOFF=1,TEMPOFF=1,PENTIME=0, NMULBAC=0,BSIDC=TRUE -1-2,RDLNKTO=7, CELLGLID="123"-"45"-1- 1,EBEAMFTX=ENABLED,TXPWRDLPTS=73, MARXPP=(-80),FBFTH=N_03_16,SLOWBFTH=N_13_16,THTXBF=5.0, MANBFEVTX=3,NREPIEV=1,NREPEV=3,THPWREV=5.0,EBFONP- a whole observation period must be present within each time-frame, i.e. TimerNoCall1 <= 6*(StartTime2 - StartTime1) TimerNoCall2 <= 6*((24 - (StartTime2 - StartTime1)) The two time-frames must be converted in periods of ten minutes. 294 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller FACH=FALSE,THPP=5.0,AVPSDMEAS=48,AVPNSME=10,NFLPD=3, CNTTHPYUL=16,PKAVDTH=12,PKSDDTH=4,CNTTH=8,PKSIDEDTH=6, PKSDDCOLLTH=6,ULSS=N_1_8,ULSRP=1,MATXDLTSX=1-25,PWRPFACH=(-3), SNRIMPRETH=0.0,PRIDLFG=0,INTTHDL=(-115),INTTHUL=(-120),INTULAVP=1, INTDLAVP=1,PRIUDPUL=1,PRIUDPDL=1,ULSIRACST=TRUE, ULDCAST=TRUE,DLDCAST=TRUE,FACCHQTD=5,SCCPCHDESC=4-0-5, UPPTSRXPL=(-110), SSUPPTS=INCR_BY_1DB,MANOUSRTS=n_16,PRACH- DESC=1-0-0-0,PFACHDESC=4-0,UETSCPMA=(-17),PREFPRIO=DEFAULT, MIULPRI=25, MIDLPRI=25,MIULPRIHO=25,MIDLPRIHO=25, TSPRILVBOUN=80-60-40-20,TDNCCPERMI=0,PLMNP=4,DLBFTH=N_03_16, DONDLPCTH=N_09_16,DONULPCTH=N_07_16,DONULSCTH=N_07_16, DLSIRACST=TRUE,EEXCDIST=TRUE,PKAVDRELTH=15, SYNC1LDAVS=192,EXCDISTTD=30000,MASONLYC=0,HREFRLDTH=1, PRIULFG=2,RXPWRDES=(-110.5),TXPPCCPCH=23,MARINTDL=0, MATXULTSX=33, PCCPCHDESC=1-0-0,BTSHSCSD=FALSE,MACRADIUS=60, PATHLSLOPE=N_0-N_0, BCIDLERESTH=50, CPPFAC=0, EXTMEPROCCLER=FALSE-FALSE-FALSE, MODLUPDMIPER=20, PKNWK=10, LCBM0=NULL,LCBM1=NULL, LCBM2=NULL, LCBM3=NULL,NFRAMEPG=2,MARACHTRANS=MAX_1_RETRANSM,TXINT=4, MASY1RETS=MAX_1_RETRANSM,T3126=63,UETXPMACC=2, CELLBARR=FALSE,CREALL=NOTALLOWED,NALLWACC=na0, SMSCBUSE=TRUE,IMSIATDT=FALSE,T3212=0, EARCLM=TRUE,EC=FALSE, T200TD=44-31-41-90-90-90, TSYNC=1000,TSYNCDL=400,TSYNCUL=400, TSYNCR=400,TTRAU=1000, T3101=HLFSEC-6,T3109=HLFSEC-24, T3111=HLFSEC-1,T3208=10, ENANCD=DISABLED,NCDP1=H8-6,NCDP2=H21- 30,DWPTSCANAINTEX=4; DELETE BTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD DELETE BTSTD Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a previously created BTSTD. Validity ranges of the object addresses "btsmtdn" and "btstdn" can be found in Appendix A. DELETE BTSTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn; A30808-X3247-L230-3-7619 295 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Delete BTSTD:NAME=BTSMTD:0/BTSTD:0; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a BTSTD, the relative object instance must be in LOCKED state. UNSUCCESSFUL_SUBORDINATE_EQUIPPED All the LAPDLRTD, ADJCTD, PTPPKFTD, object instances associated to the BTSTD object instance must be previously deleted. The BTSTDobject instance cannot be deleted if it is referenced as the target cell by any ADJCTD object. COLOCATE_RELATIONSHIP_PRESENT If the BTSTDis defined colocated to other BTSTDs of the BSC, all the colocated relationships with other BTSTDs of the BSC have to be removed before deleting the BTSTD. 296 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET BTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD GET BTSTD Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the cell global parameters of a previously created BTSTD. Validity ranges of the object addresses "btsmtdn" and "btstdn" can be found in Appendix A. GET BTSTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn [,REQATTL=BCCHFREQTD, CALLF<nn>TD, PCCCHLDI, RACHBT, RACHLAS, TCCCHLDI, NF1, CELLRESH, RXLEVAMITD, CBQ, CRESOFF, TEMPOFF, PENTIME, NMULBAC, BSIDC, RDLNKTO, CELLGLID, EBEAMFTX, TXPWRDLPTS, MARXPP, FBFTH, SLOWBFTH, THTXBF, MANBFEVTX, NREPIEV, NREPEV, THPWREV, EBFONPFACH, THPP, AVPSDMEAS, AVPNSME, NFLPD ,CNTTH- PYUL, PKAVDTH, PKSDDTH, CNTTH, PKSIDEDTH, PKSDDCOLLTH, ULSS, ULSRP, MATXDLTSX, PWRP- FACH,SNRIMPRETH, PRIDLFG, INTTHDL, INTTHUL, INTULAVP, INTDLAVP, PRIUDPUL, PRIUDPDL, ULSIRACST, ULDCAST, DLDCAST, FACCHQTD, SCCPCHDESC, UPPTSRXPL, SSUPPTS, MANOUSRTS, PRACHDESC, PFACH- DESC,UETSCPMA, PREFPRIO, MIULPRI, MIDLPRI, MIULPRIHO, MIDLPRIHO, TSPRILVBOUN, TDNC- CPERMI, PLMNP, DLBFTH, DONDLPCTH, DONULPCTH, DONULSCTH, DLSIRACST, EEXCDIST, PKAVDRELTH, SYNC1LDAVS, EXCDISTTD, MASONLYC, HREFRLDTH, PRIULFG, RXPWRDES, TXPPCCPCH, MARINTDL, MATXULTSX, PCCPCH- DESC, BTSHSCSD, MACRADIUS, PATHLSLOPE, BCIDLERESTH, CPPFAC, EXTMEPROCCLER, MODLUPDMIPER, NFRAMEPG, MARACHTRANS, TXINT, MASY1RETS, T3126, UETXPMACC, CELL- BARR, CREALL, NALLWACC, SMSCBUSE, IMSIATDT, T3212, EARCLM, EC, T200TD, TSYNC, TSYNCDL, TSYNCUL, TSYNCR, TTRAU, T3101, T3109, T3111, T3208, PKNWK, ENANCD, NCDP1, NCDP2, LCBM0, LCBM1, LCBM2, LCBM3, DWPTSCANAINTEX]; (where <nn> = 01 to 63) A30808-X3247-L230-3-7619 297 Commands Base Station Controller CML:BSC System Responses: GET ACK: NAME:name BCCHFREQTD:bcchFrequencyTD CALLF01TD:cellAllocationF01TD CALLF02TD:cellAllocationF02TD PCCCHLDI: periodCcchLoadIndication RACHBT: rachBusyThreshold RACHLAS: rachLoadAveragingSlots TCCCHLDI: thresholdCcchLoadIndication NF1: nf1 CELLRESH: cellReselectHysteresis RXLEVAMITD: rxLevAccessMinTd CBQ:CellBarQualify CRESOFF:cellReselectOffset TEMPOFF:temporaryOffset PENTIME:penaltyTime NMULBAC:nMultibandcell BSIDC: bsIdentityCodeTD NCC: Network Colour Code BCC: Bs Colour Code RDLNKTO: radioLinkTimeout CELLGLID: MCC: mcc MNC: mnc LAC: lac CI: ci EBEAMFTX: enableBeamformTX TXPWRDLPTS: txPwrOfDwPTS MARXPP: maxRXPowerParty FBFTH: fastBFThreshold SLOWBFTH: slowBFThreshold THTXBF: thresTXBF MANBFEVTX: maxNumBFEVTX NREPIEV: numRepIntEV NREPEV:numRepEV THPWREV: thresPowerEV EBFONPFACH: enableBFOnPFACH THPP: thresPostProcessing AVPSDMEAS: averagePeriodSDMeas AVPNSME: averagePeriodNoiseMeas NFLPD: numOfFrLinPreDelay CNTTHPYUL: cntThresPartyUL PKAVDTH: peakAverageDiffThres PKSDDTH: peakSideDiffThres CNTTH: countThreshold PKSIDEDTH: peakSideTimeDiffThres 298 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PKSDDCOLLTH: peakSideDiffCollThres ULSS: uLSCStep ULSRP: uLSCRep MATXDLTS: maxTXDLTSX numberOfCarriers maxTXDLTSX PWRPFACH: pwrPFACH SNRIMPRETH: snrOfImpulseRespThres PRIDLFG: priorityDLForget INTTHDL: interferenceThresDL INTTHUL: interferenceThresUL INTULAVP: interferenceULAvePer INTDLAVP: interferenceDLAvePer PRIUDPUL: priorityUpdatePeriodUL PRIUDPDL: priorityUpdatePeriodDL ULSIRACST: uplinkSIRACStatus ULDCAST: uplinkDCAStatus DLDCAST: downlinkDCAStatus FACCHQTD: facchQualTd SCCPCHDESC: Timeslot TSC BlkAGCH UPPTSRXPL: upPTSRXPL SSUPPTS: stepSizeUpPTS MANOUSRTS: maxNofUsersPerTS PRACHDESC: Timeslot TSC SC P_RACH_AGCH PFACHDESC: Timeslot TSC UETSCPMA: ueTSCPMax PREFPRIO: prefPriorities MIULPRI: minULPriority MIDLPRI: minDLPriority MIULPRIHO: minULPriorityHO MIDLPRIHO: minDLPriorityHO TSPRILVBOUN: tSPriorityLevelBoundaries priorityBounderie1 priorityBounderie2 priorityBounderie3 priorityBounderie4 TDNCCPERMI: tdnccPermitted PLMNP: plmnPermitted A30808-X3247-L230-3-7619 299 Commands Base Station Controller CML:BSC DLBFTH: dLBFThreshold DONDLPCTH: doNothingDLPCThreshold DONULPCTH: doNothingULPCThreshold DONULSCTH: doNothingULSCThreshold DLSIRACST: downlinkSIRACStatus EEXCDIST: enableExcessiveDistance PKAVDRELTH: peakAverDiffRelThres SYNC1LDAVS: sync1LoadAverSlots EXCDISTTD: excessiveDistanceTD MASONLYC: maxSignallingonlyCodes HREFRLDTH: hREFRLoadThreshold PRIULFG: priorityULForget RXPWRDES: rxPWRDes TXPPCCPCH: txPwrOfPCCPCH MARINTDL: marIntDL MATXULTSX: maxTXULTSX PCCPCHDESC: Blk_BCCH Blk_AGCH Blk_CBCH BTSHSCSD: btsHSCSD MACRADIUS: maxCellRadius PATHLSLOPE: pathLossSlope aPar bPar BCIDLERESTH: bcchIdleResThr CPPFAC: carrierPartitioningByPassFactor EXTMEPROCCLER: extMeasProcController FirstNormalAss FollNormalAss IntracellHO MODLUPDMIPER: moDListUpdatingMinPeriodicity NFRAMEPG:noOfMultiFramesBetweenPaging MARACHTRANS: maxRachTrans TXINT: txInteger MASY1RETS: maxSync1Retrans T3126: t3126 UETXPMACC: uETxPwrMaxCcch CELLBARR:cellBarred CREALL:callReestablishmentAllowed NALLWACC: Not Allowed Access Class : notAllowedAccessClasses 0 Not Allowed Access Class : notAllowedAccessClasses 1 Not Allowed Access Class : notAllowedAccessClasses 2 Not Allowed Access Class : notAllowedAccessClasses 3 Not Allowed Access Class : notAllowedAccessClasses 4 Not Allowed Access Class : notAllowedAccessClasses 5 300 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Not Allowed Access Class : notAllowedAccessClasses 6 Not Allowed Access Class : notAllowedAccessClasses 7 Not Allowed Access Class : notAllowedAccessClasses 8 Not Allowed Access Class : notAllowedAccessClasses 9 Not Allowed Access Class : notAllowedAccessClasses 10 Not Allowed Access Class : notAllowedAccessClasses 11 Not Allowed Access Class : notAllowedAccessClasses 12 Not Allowed Access Class : notAllowedAccessClasses 13 Not Allowed Access Class : notAllowedAccessClasses 14 Not Allowed Access Class : notAllowedAccessClasses 15 SMSCBUSE:smsCBUsed IMSIATDT:allowImsiAttachDetach T3212:timerPeriodicUpdateMS EARCLMenableEarlyClassmark EC:emergencyCallRestricted T200TD: sdcchSAPIO:sdcchSAPIO facchTCHF: facchTCHF facchTCHH: facchTCHH sacchTCHSAPIO:sacchTCHSAPIO sacchSDCCH:sacchSDCCH sdcchSAPI3: sdcchSAPI3 sacchTCHSAPI3:sacchTCHSAPI3 TSYNC:tSync TSYNCUL:tSynchronizationUplink TSYNCDL:tSynchronizationDownlink TSYNCR:tSynchronizationR TTRAU:tTrau T3101: Tunit:tunit Tvalue:tvalue T3109: Tunit:tunit Tvalue:tvalue T3111: Tunit:tunit Tvalue:tvalue T3208: t3208 PKNWK: pkNWK ENANCD:enableNoCallDetection NCDP1: StartTime1:StartTime1 TimerNoCall1:TimerNoCall1 NCDP2: StartTime2:StartTime2 TimerNoCall2:TimerNoCall2 LCBM0:localCellBroadcastMessage0 A30808-X3247-L230-3-7619 301 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get BTSTD:NAME=BTSMTD:0/BTSTD:0,BCCHFREQTD&CALLF01TD& DCALLF02TD& PCCCHLDI&RACHBT&RACHLAS&TCCCHLDI&NF1=& CELLRESH&RXLEVAMITD&CBQ&CRESOFF&TEMPOFF&PENTIME&NMULBAC& BSIDC&RDLNKTO&CELLGLID&EBEAMFTX&TXPWRDLPTS&MARXPP&FBFTH&SL OWBFTH&THTXBF&MANBFEVTX&NREPIEV&NREPEV&THPWREV&EBFONP- FACH&THPP&AVPSDMEAS&AVPNSME&NFLPD&CNTTH- PYUL&PKAVDTH&PKSDDTH&CNTTH&PKSIDEDTH&PKSDDCOLLTH&ULSS&ULS RP&MATXDLTSX&PWRPFACH&SNRIMPRETH&PRIDLFG&INTTHDL&INTTHUL &INTULAVP&INTDLAVP&PRIUDPUL&PRIUDPDL&ULSIRACST&ULDCAST& DLDCAST&FACCHQTD&SCCPCHDESC&UPPTSRXPL& SSUPPTS&MANOUSRTS&PRACHDESC&PFACHDESC&UETSCPMA& PREFPRIO&MIULPRI&MIDLPRI&MIULPRIHO&MIDLPRIHO&TSPRIL- VBOUN&TDNCCPERMI&PLMNP&DLBFTH& DONDLPCTH& DONULPCTH&DONULSCTH&DLSIRACST&EEXCDIST&PKAVDRELTH &SYNC1LDAVS&EXCDISTTD& MASONLYC&HREFRLDTH&PRIULFG &RXPWRDES&TXPPCCPCH&MARINTDL&MATXULTSX&PCCPCHDESC&BTSH- SCSD&MACRADIUS&PATHLSLOPE&BCIDLERESTH&CPPFAC& EXTMEPROCCLER&MODLUPDMIPER&NFRAMEPG&MARACHTRANS& MSGID:MSGID PAGE:PAGE REPRATE:REPRATE SCHEME:SCHEME LCBM1:localCellBroadcastMessage1 MSGID:MSGID PAGE:PAGE REPRATE:REPRATE SCHEME:SCHEME LCBM2:localCellBroadcastMessage2 MSGID:MSGID PAGE:PAGE REPRATE:REPRATE SCHEME:SCHEME LCBM3:localCellBroadcastMessage3 MSGID:MSGID PAGE:PAGE REPRATE:REPRATE SCHEME:SCHEME DWPTSCANAINTEX=dwPtsCancelAvIntensExp GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 302 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TXINT&MASY1RETS&T3126&UETXPMACC&CELLBARR&CREALL&NALL- WACC&SMSCBUSE&IMSIATDT&T3212&EARCLM&EC&T200TD& TSYNC&TSYNCDL&TSYNCUL&TSYNCR&TTRAU&T3101&,T3109&T3111&T3208& PKNWK&ENANCD&NCDP1&NCDP2&LCBM0&LCBM1&LCBM2&LCBM3&DWPTSC ANAINTEX; GET BTSTD BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD GET BTSTD BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses "btsmtdn" and "btstdn" can be found in Appendix A. System Responses: GET BTSTD BASICS: NAME=BTSMTD:btsmtdn/BTSTD:btstdn; GET ACK: NAME:name BCCHFREQTD:bcchFrequencyTD CALLF01TD:cellAllocationF01TD CALLF02TD:cellAllocationF02TD PCCCHLDI: periodCcchLoadIndication RACHBT: rachBusyThreshold RACHLAS: rachLoadAveragingSlots TCCCHLDI: thresholdCcchLoadIndication NF1: nf1 CELLRESH: cellReselectHysteresis RXLEVAMITD: rxLevAccessMinTd CBQ:CellBarQualify CRESOFF:cellReselectOffset TEMPOFF:temporaryOffset PENTIME:penaltyTime NMULBAC:nMultibandcell BSIDC: bsIdentityCodeTD NCC: Network Colour Code BCC: Bs Colour Code RDLNKTO: radioLinkTimeout CELLGLID: A30808-X3247-L230-3-7619 303 Commands Base Station Controller CML:BSC MCC: mcc MNC: mnc LAC: lac CI: ci EBEAMFTX: enableBeamformTX TXPWRDLPTS: txPwrOfDwPTS MARXPP: maxRXPowerParty FBFTH: fastBFThreshold SLOWBFTH: slowBFThreshold THTXBF: thresTXBF MANBFEVTX: maxNumBFEVTX NREPIEV: numRepIntEV NREPEV:numRepEV THPWREV: thresPowerEV EBFONPFACH: enableBFOnPFACH THPP: thresPostProcessing AVPSDMEAS: averagePeriodSDMeas AVPNSME: averagePeriodNoiseMeas NFLPD: numOfFrLinPreDelay CNTTHPYUL: cntThresPartyUL PKAVDTH: peakAverageDiffThres PKSDDTH: peakSideDiffThres CNTTH: countThreshold PKSIDEDTH: peakSideTimeDiffThres PKSDDCOLLTH: peakSideDiffCollThres ULSS: uLSCStep ULSRP: uLSCRep MATXDLTS: maxTXDLTSX numberOfCarriers maxTXDLTSX PWRPFACH: pwrPFACH SNRIMPRETH: snrOfImpulseRespThres PRIDLFG: priorityDLForget INTTHDL: interferenceThresDL INTTHUL: interferenceThresUL INTULAVP: interferenceULAvePer INTDLAVP: interferenceDLAvePer PRIUDPUL: priorityUpdatePeriodUL PRIUDPDL: priorityUpdatePeriodDL ULSIRACST: uplinkSIRACStatus ULDCAST: uplinkDCAStatus DLDCAST: downlinkDCAStatus FACCHQTD: facchQualTd SCCPCHDESC: Timeslot TSC BlkAGCH 304 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller UPPTSRXPL: upPTSRXPL SSUPPTS: stepSizeUpPTS MANOUSRTS: maxNofUsersPerTS PRACHDESC: Timeslot TSC SC P_RACH_AGCH PFACHDESC: Timeslot TSC UETSCPMA: ueTSCPMax PREFPRIO: prefPriorities MIULPRI: minULPriority MIDLPRI: minDLPriority MIULPRIHO: minULPriorityHO MIDLPRIHO: minDLPriorityHO TSPRILVBOUN: tSPriorityLevelBoundaries priorityBounderie1 priorityBounderie2 priorityBounderie3 priorityBounderie4 TDNCCPERMI: tdnccPermitted PLMNP: plmnPermitted DLBFTH: dLBFThreshold DONDLPCTH: doNothingDLPCThreshold DONULPCTH: doNothingULPCThreshold DONULSCTH: doNothingULSCThreshold DLSIRACST: downlinkSIRACStatus EEXCDIST: enableExcessiveDistance PKAVDRELTH: peakAverDiffRelThres SYNC1LDAVS: sync1LoadAverSlots EXCDISTTD: excessiveDistanceTD MASONLYC: maxSignallingonlyCodes HREFRLDTH: hREFRLoadThreshold PRIULFG: priorityULForget RXPWRDES: rxPWRDes TXPPCCPCH: txPwrOfPCCPCH MARINTDL: marIntDL MATXULTSX: maxTXULTSX PCCPCHDESC: Blk_BCCH Blk_AGCH Blk_CBCH BTSHSCSD: btsHSCSD MACRADIUS: maxCellRadius PATHLSLOPE: pathLossSlope A30808-X3247-L230-3-7619 305 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get BTSTD BASICS:NAME=BTSMTD:0/BTSTD:0; GET BTSTD CCCH BCIDLERESTH: bcchIdleResThr CPPFAC: carrierPartitioningByPassFactor EXTMEPROCCLER: extMeasProcController FirstNormalAss FollNormalAss IntracellHO MODLUPDMIPER: moDListUpdatingMinPeriodicity PKNWK: pkNWK LCBM0:localCellBroadcastMessage0 MSGID:MSGID PAGE:PAGE REPRATE:REPRATE SCHEME:SCHEME LCBM1:localCellBroadcastMessage1 MSGID:MSGID PAGE:PAGE REPRATE:REPRATE SCHEME:SCHEME LCBM2:localCellBroadcastMessage2 MSGID:MSGID PAGE:PAGE REPRATE:REPRATE SCHEME:SCHEME LCBM3:localCellBroadcastMessage3 MSGID:MSGID PAGE:PAGE REPRATE:REPRATE SCHEME:SCHEME DWPTSCANAINTEX:dwPtsCancelAvIntensExp GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET BTSTD CCCH: NAME=BTSMTD:btsmtdn/BTS:btstdn; 306 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD GET BTSTD CCCH Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the CCCH group. Validity ranges of the object addresses "btsmtdn" and "btstdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get BTSTD CCCH:NAME=BTSMTD:0/BTSTD:0; GET BTSTD OPTIONS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD GET BTSTD OPTIONS Applicability: Phase 2. Visibility level 0. GET ACK: NAME:name NFRAMEPG:noOfMultiFramesBetweenPaging MARACHTRANS: maxRachTrans TXINT: txInteger MASY1RETS: maxSync1Retrans T3126: t3126 UETXPMACC: uETxPwrMaxCcch GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET BTSTD OPTIONS: NAME=BTSMTD:btsmtdn/BTSTD:btstdn; A30808-X3247-L230-3-7619 307 Commands Base Station Controller CML:BSC Command Description: This command is used to retrieve the values of all the parameters of the OPTIONS group. Validity ranges of the object addresses "btsmtdn" and "btstdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get BTSTD OPTIONS:NAME=BTSMTD:0/BTSTD:0; GET ACK: NAME:name CELLBARR:cellBarred CREALL:callReestablishmentAllowed NALLWACC: Not Allowed Access Class : notAllowedAccessClasses 0 Not Allowed Access Class : notAllowedAccessClasses 1 Not Allowed Access Class : notAllowedAccessClasses 2 Not Allowed Access Class : notAllowedAccessClasses 3 Not Allowed Access Class : notAllowedAccessClasses 4 Not Allowed Access Class : notAllowedAccessClasses 5 Not Allowed Access Class : notAllowedAccessClasses 6 Not Allowed Access Class : notAllowedAccessClasses 7 Not Allowed Access Class : notAllowedAccessClasses 8 Not Allowed Access Class : notAllowedAccessClasses 9 Not Allowed Access Class : notAllowedAccessClasses 10 Not Allowed Access Class : notAllowedAccessClasses 11 Not Allowed Access Class : notAllowedAccessClasses 12 Not Allowed Access Class : notAllowedAccessClasses 13 Not Allowed Access Class : notAllowedAccessClasses 14 Not Allowed Access Class : notAllowedAccessClasses 15 SMSCBUSE:smsCBUsed IMSIATDT:allowImsiAttachDetach T3212:timerPeriodicUpdateMS EARCLMenableEarlyClassmark EC:emergencyCallRestricted GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 308 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET BTSTD STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD GET BTSTD STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the BTSTD object: Administrative State (AST) Operational State (OST) Usage State (UST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Unknown Status (UNK). Validity ranges of the object addresses "btsmtdn" and "btstdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get BTSTD STAT:NAME=BTSMTD:0/BTSTD:0; GET BTSTD STAT: NAME=BTSMTD:btsmtdn/BTS:btstdn; GET BTS STAT ACK: GET BTS STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 309 Commands Base Station Controller CML:BSC GET BTSTD TIMER Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD GET BTSTD TIMER Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the TIMER group. Validity ranges of the object addresses "btsmtdn" and "btstdn" can be found in Appendix A. System Responses: GET BTSTD TIMER: NAME=BTSMTD:btsmtdn/BTSTD:btstdn; GET ACK: NAME:name T200TD: sdcchSAPIO:sdcchSAPIO facchTCHF: facchTCHF facchTCHH: facchTCHH sacchTCHSAPIO:sacchTCHSAPIO sacchSDCCH:sacchSDCCH sdcchSAPI3: sdcchSAPI3 sacchTCHSAPI3:sacchTCHSAPI3 TSYNC:tSync TSYNCUL:tSynchronizationUplink TSYNCDL:tSynchronizationDownlink TSYNCR:tSynchronizationR TTRAU:tTrau T3101: Tunit:tunit Tvalue:tvalue T3109: Tunit:tunit Tvalue:tvalue T3111: Tunit:tunit Tvalue:tvalue T3208: t3208 ENANCD:enableNoCallDetection NCDP1: StartTime1:StartTime1 310 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get BTSTD TIMER:NAME=BTSMTD:0/BTSTD:0; GETINFO BTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD GETINFO BTSTD Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The administrative state (AST), the operational state (OST), the usage state (UST), the availability status (AVS) and the procedural status (PRS) of the BTSTD. 2. The BTSTD absolute number. 3. The BCCH TRXTD number. 4. The P-CCPCH information. 5. The S-CCPCHs information. 6. The P-FACHs information. 7. The P-RACHs information. 8. The barred cell information. 9. The Cell Global Identier information. 10. The Routing Area (RA) code. 11. The TD-SCDMA packet switched service (TD-PRS) available information. 12. The BVCI number. 13. Full rate speech: number of channels used for full rate speech. 14. Full rate data: number of channels used for full rate data. 15. Half rate speech: number of subchannels used for half rate speech calls (number of calls). TimerNoCall1:TimerNoCall1 NCDP2: StartTime2:StartTime2 TimerNoCall2:TimerNoCall2 GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETINFO BTSTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn; A30808-X3247-L230-3-7619 311 Commands Base Station Controller CML:BSC 16. Number of resources used for packet service. 17. The TDCU number. 18. For each TRXTD of the BTSTD: the state and statuses: AST, OST, UST, AVS, PRS; 19. For each AIRTSTD of the TRXTD: the administrative, operational, usage states, the availability status . Validity ranges of the object addresses "btsmtdn" and "btstdn" can be found in Appendix A. System Responses: GETINFO BTSTD ACK: BSC_CONTROLLER -> LMT_LOCAL 03:21:35 01/01/1992 *** INFORMATION *** GET INFO REPORT BTSTD: NAME = BTSTD:112 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED USAGE STATE: IDLE AVAILABILITY STATUS: NONE PROCEDURAL STATUS: NONE BTSTD ABSOLUTE NR: 3 BCCH TRXTD NR: 0 P_CCPCH BLK_CBCH 1 S_CCPCH[0] TIMESLOT TS_04 TSC SC BLK_CBCH 0 S_CCPCH[1] TIMESLOT TS_04 TSC SC BLK_CBCH 0 S_CCPCH[2] TIMESLOT TS_04 TSC SC BLK_CBCH 0 P_FACH[0] TIMESLOT TS_04 TSC 312 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SC P_FACH[1] TIMESLOT TS_02 TSC SC P_FACH[2] TIMESLOT TS_02 TSC SC P_RACH[0] TIMESLOT TS_01 TSC SC P_RACH[1] TIMESLOT TS_01 TSC SC P_RACH[2] TIMESLOT TS_01 TSC SC CELL BARRED: TRUE CELL BARRED REASON: FREQ_CHANGE CELL GLOBAL CODE: 123-32-387-984 RA CODE: 3 TDPRS AVAILABLE: TRUE BVCI: 3 FULL SPEECH BUSY CH: 0 FULL DATA BUSY CH: 5 HALF SPEECH BUSY SUBCH: 3 PACKET BUSY CH: 5 TDCU NUMBER: 3 TRXTD 0: ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED USAGE STATE: NONE AVAILABILITY STATUS: NONE PROCEDURAL STATUS: YES A30808-X3247-L230-3-7619 313 Commands Base Station Controller CML:BSC AIRTSTD NR ADMINISTRATIVE OPERATIONAL USAGE AVAILABILITY 0 LOCKED ENABLED IDLE NONE 1 UNLOCKED ENABLED IDLE NONE 2 UNLOCKED ENABLED IDLE NONE 3 UNLOCKED ENABLED IDLE NONE 4 UNLOCKED ENABLED IDLE NONE 5 UNLOCKED ENABLED IDLE NONE 6 UNLOCKED ENABLED IDLE NONE ........ TRXTD 2: ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED USAGE STATE: NONE AVAILABILITY STATUS: NONE PROCEDURAL STATUS: YES AIRTSTD NR ADMINISTRATIVE OPERATIONAL USAGE AVAILABILITY 0 LOCKED ENABLED IDLE NONE 1 UNLOCKED ENABLED IDLE NONE 2 UNLOCKED ENABLED IDLE NONE 3 UNLOCKED ENABLED IDLE NONE 4 UNLOCKED ENABLED IDLE NONE 5 UNLOCKED ENABLED IDLE NONE 6 UNLOCKED ENABLED IDLE NONE GETINFO BTSTD NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1*** Get Info Report Nack BTSTD: name = BTSTD:112 nackCause = <nack cause> NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the system. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. 314 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. CELL BARRED Status attribute is not meaningful when the cell is barred because there are no SS7Ls available or when the operator directly bars the cell setting the attributes CBQ and CBA of the BTS. 2. The CELL BARRED REASON information is reserved for the developer. 3. TRXs that are not equipped in the BTS are not shown in the report. Example of Command Execution Getinfo BTS:NAME=BTSM:0/BTS:0; GETRELATIONSHIP BTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD GETRELA- TIONSHIP BTSTD Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of the all HMOs (Hardware Managed Object) supporting the FMO functionality. For the BTSTDobject the related HMOs are the following: LICD/LICDS, EPWR, PWRD, MPCC, TDPC, MEMT, NTW, PPXT and all the BTSE HMOs that implement the TRXTD functionality for a certain BTSTD. Validity ranges of the object addresses "btsmtdn" and "btstdn" can be found in Appendix A. System Responses: Application Guidelines: None. GETRELATIONSHIP BTSTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The object does not provide any relationship attribute. A30808-X3247-L230-3-7619 315 Commands Base Station Controller CML:BSC Example of Command Execution Getrelationship BTSTD:NAME=BTSMTD:0/BTSTD:0; GETSUBO BTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD GETSUBO BTSTD Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. Validity ranges of the object addresses "btsmtdn" and "btstdn" can be found in Appendix A. System Responses Application Guidelines: None. Example of Command Execution Getsubo BTSTD:NAME=BTSMTD:0/BTSTD:0; LOCK BTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD LOCK BTSTD GETSUBO BTSTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn; GETSUBO ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GET BTS STATUS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK BTSTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn; 316 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state "Locked". Validity ranges of the object addresses "btsmtdn" and "btstdn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock BTSTD:NAME=BTSMTD:0/BTSTD:0; LOCK BTSTD ACK: LOCK BTSTD NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 317 Commands Base Station Controller CML:BSC SET BTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD SET BTSTD Applicability: Phase 2. Visibility level 2. SET BTSTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn [BCCH- FREQTD=] [,CALLF<nn>TD=] [,PCCCHLDI=] [,RACHBT=] [,RACHLAS=] [,TCCCHLDI=] [,NF1=] [,CELLRESH=] [,RXLEVAMITD=] [,CBQ=] [,CRESOFF=] [,TEMPOFF=] [,PENTIME=] [,NMULBAC=], BSIDC= [,RDLNKTO=] , CELLGLID= [,EBEAMFTX=] [,TXPWRDLPTS=] [,MARXPP=] [,FBFTH=] [,SLOWBFTH=] [,THTXBF=] [,MANBFEVTX=] [,NREPIEV=] [,NREPEV=] [,THPWREV=] [,EBFONPFACH=] [,THPP=] [,AVPSD- MEAS=] [,AVPNSME=] [,NFLPD=] [,CNTTHPYUL=] [,PKAVDTH=] [,PKSDDTH=] [,CNTTH=] [,PKSID- EDTH=] [,PKSDDCOLLTH=] [,ULSS=] [,ULSRP=] ,MATXDLTSX= [,PWRPFACH=] [,SNRIMPRETH=] , PRIDLFG=, INTTHDL=, INTTHUL=, INTULAVP=, INTD- LAVP=, PRIUDPUL=, PRIUDPDL= [,ULSIRACST=] [,ULDCAST=] [,DLDCAST=] [,FACCHQTD=] [,SCCPCHDESC=] [,UPPTSRXPL=] [,SSUPPTS=] [,MANOUSRTS=] ,PRACHDESC=, PFACHDESC= [,UETSCPMA=] [,PREFPRIO=] [,MIULPRI=] [, MIDLPRI=] [,MIULPRIHO=] [,MIDLPRIHO=] [,TSPRIL- VBOUN=] , TDNCCPERMI= [,PLMNP=] [,DLBFTH=] [,DONDLPCTH=] [,DONULPCTH=] [,DONULSCTH=] [,DLSIRACST=] [,EEXCDIST=] [,PKAVDRELTH=] [,SYNC1LDAVS=] [,EXCDISTTD=] , MASONLYC=, HREFRLDTH= ,PRIULFG= [,RXPWRDES=] [,TXPPC- CPCH=] , MARINTDL= [,MATXULTSX=] , PCCPCH- DESC= [,BTSHSCSD=] [,MACRADIUS=] , PATHLSLOPE= [,BCIDLERESTH=] [,CPPFAC=] [,EXTMEPROCCLER=] [,MODLUPDMIPER=] [,PKNWK=][,LCBM0=] [,LCBM1=] [,LCBM2=] [,LCBM3=] [,NFRAMEPG=] [,MARACHTRANS=][,TXINT=] [,MASY1RETS=] [,T3126=] [,UETXPMACC=] [,CELLBARR=] [,CREALL=] [,NALLWACC=] [,SMSCBUSE=] [,IMSIATDT=] [,T3212=] [,EARCLM=] [,EC=] [,T200TD=] [,TSYNC=] [,TSYNCUL=,] [,TSYNCDL=] [,TSYNCR=] [,TTRAU=,] [,T3101=] [,T3109=] [,T3111=] [,T3208=] [ENANCD=] [,NCDP1=] [,NCDP2=][,DWPTSCANAINTEX] ; (where <nn> = 01 to 63) 318 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command modifies the configuration of a cell by specifying the global parameters necessary for the creation. The attributes within this object describe the basic properties of a BTSTD which are not related to the Common Control Channels. Validity ranges of the object addresses "btsmtdn" and "btstdn" can be found in Appendix A. System Responses: Application Guidelines: 1. Three attributes in the BTSTDManaged Object are formatted in digits; the attributes are: CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOT_EQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. For more details see Application Guidelines n. 1, n. 3, n. 4, n. 5, n.6, n.10, n.11, n.12, n.13, n.14, n.15, n.16, n.17. UNSUCCESSFUL_CELL_GLOB_ID All the fields of cellGlobalIdentity must be set in the following combination: MCC, MNC, LAC, CI, where: Location Area Identity (LAI) = MCC + MNC + LAC; Cell Global Identity = LAI + CI. The CELLGLID cannot be equal to the CELLGLID assigned to another BTS, TGTBTS, BTSTD, or TGTBTSTD. UNSUCCESSFUL_EQUAL_FREQ BCCHFREQTD, CALLF01TDand CALLF02TDattributes cannot assume the same values. UNSUCCESSFUL_OVERLAP_BAND The distance between any pair of frequency attributes must be at least 1.6 MHz. UNSUCCESSFUL_SUM_OF_BLOCKS_NOT_ALLOWED On P-CCPCH the sum of blocks for BCCH, AGCH, CBCH, Reserved Blocks (Blk_AGCH+Blk_RES+ Blk_CBCH + Blk_BCCH) must be lower than 9. On all configured S-CCPCH the sum of blocks for AGCH and reserved Blocks (Blk_AGCH + Blk_RES) must be 12 BCCFTD_AND_BSIDC_BELONG_TO_ANOTHER_CELL The pair BCCHFREQTD - BSIDC must be different fromthe pair BCCHFREQTD - BSIDC of an existing cell or TGTBTSTD. UNSUCCESSFUL_INVALID_STATUS The BSIDC,CELLGLID, EBEAMFTX, SCCPCHDESC, MANOUSRTS, PRACHDESC, PFACHDESC, PCCPCHDESC attributes can be set only if the BTSTD object is in LOCKED state. A30808-X3247-L230-3-7619 319 Commands Base Station Controller CML:BSC the MobileCountryCode (MCC) and the MobileNetworkCode (MNC) contained in the CellGlobalId (CELLGLID); the bSIdentityCodeTD (BSIDC); 2. After the creation of the object, the ADMINISTRATIVE state of this object is set at LOCKED. An UNLOCK command is required to put this object in service. 3. The HSCSD service can be activated in the cell (BTSHSCSD = TRUE) only if the HSCSD service is activated at BSC side (ENHSCSD attribute of BSC set at TRUE). 4. If the excessive distance is enabled (EEXCDIST = TRUE) the value assigned to the attribute EXCDISTTD must be greater than the value assigned to the distance handover threshold hoThresholdMsRangeMax (attribute HOTMSRMTD of HANDTD object) 5. For the attribute NCDP2, the TimerNoCall2 eld can be set only if the StarTime2 eld is different from NOTUSED. 6. If the second time-frame is congured by the NCDP2 setting, the StartTime2 value must be greater than the StartTime1 eld of NCDP1 attribute. If the second time-frame is congured by the NCDP2 setting, the following congu- ration rule must be satised: 7. LCBMx attributes can be set at a value different from NULL only if no CBCL instances have been already equipped. 8. The timers TSYNC and TTRAU must be set longer than ALARMT2 (see LICD object). The timers TSYNC and TTRAU must be set longer than BSCT10 (BSC CELLGLID = MCC-MNC-LAC-CI Note that MCC = D1D2D3 MNC = D1D2D3 Dx means digit (only numerical characters shall be used; for numbers from 0 to 9 it must be entered one digit). In fact 9 is different from 09. For MCC all digits are mandatory while for MNC only D1 is mandatory. BSIDC = D1D2 Dx means digit (only numerical characters 0..7 shall be used) Note that D1 is the NetworkColourCode (NCC) and D2 is the BTSTDColourCode (BCC) This attributes are stored in the system in their decimal representation (which is the input format) but it is necessary to check the range of each digit: MCC, MNC 0 =< Dx =< 9 BSIDC 0 =< Dx =< 7 Do not configure cells without giving a value to the parameter Cell Identifier (CI) of the Cell Global Identifier attribute belonging to the BTSTD BASICS group because such cells are not handled by the system. a whole observation period must be present within each time-frame, i.e. TimerNoCall1 <= 6*(StartTime2 - StartTime1) TimerNoCall2 <= 6*((24 - (StartTime2 - StartTime1)) The two time-frames must be converted in periods of ten minutes. 320 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller object) and BSCT8 (BSC object). This is to ensure that a signalling failure (BSCT8 and BSCT10) is detected before a transcoder failure (TSYNC and TTRAU). The attribute TSYNC should be equal to TTRAU attribute. 9. In order to enable the HSCSDservice, the EARCLMattribute must be previously set at TRUE. 10. The following relationship between the MANOUSRTS attribute and the TSC eld of PRACHDESC, PFACHDESC, SCCPCHDESC parameters must be fullled: TSC <= MANOUSRTS - 1 11. For all congured PRACHDESC, if the timeslot elds are equal, then: the TSC elds must be different; the SC elds must be different; the SC elds must belong to the same range ([0..15] or [16..23], which indicates SF = 16 or SF = 8 respectively). 12. For all congured PFACHDESC, if the timeslot elds are equal, the TSC elds must be different. 13. For all congured SCCPCHDESC, if the timeslot elds are equal, the TSC elds must be different. 14. For all congured PFACHDESC and SCCPCHDESC, if any timeslot eld of PFACH- DESCis equal to any timeslot eld of SCCPCHDESC, the TSCeld of PFACHDESC must be different from the TSC eld of SCCPCHDESC. 15. Blk_AGCHeld must be always congured: either on only one S-CCPCHcongured or on PCCPCH. Congured means blk_AGCH different from 0. 16. The MANOUSRTS attribute, the TSC elds of the PFACHDESC attribute, and the preferredSF attribute of the AIRTSTDobject, (if it is created, that is, instance dened in timeslot subeld) must fulll the requirement dened in OVSF code tree in order to determine proprer Speading Code. 17. The MANOUSRTS attribute, the TSC elds of the SCCPCHDESC attribute, and the preferredSF attribute of the AIRTSTDobject, (if it is created, that is, instance dened in timeslot subeld) must fulll the requirement dened in OVSF code tree in order to determine proprer Speading Code. Example of Command Execution Set BTSTD:NAME=BTSMTD:0/BTSTD:0,BCCHFREQTD=60, CALLF01TD=10, PCCCHLDI=255,RACHBT=27,RACHLAS=204,TCCCHLDI=100,NF1=127, CELLRESH=2,RXLEVAMITD=6,CBQ=0,CRESOFF=1,TEMPOFF=1,PENTIME=0, NMULBAC=0,BSIDC=TRUE -1-2,RDLNKTO=7, CELLGLID="123"-"45"-1- 1,EBEAMFTX=ENABLED,TXPWRDLPTS=73, MARXPP=(-80),FBFTH=N_03_16,SLOWBFTH=N_13_16,THTXBF=5.0, MANBFEVTX=3,NREPIEV=1,NREPEV=3,THPWREV=5.0,EBFONP- FACH=FALSE,THPP=5.0,AVPSDMEAS=48,AVPNSME=10,NFLPD=3, CNTTHPYUL=16,PKAVDTH=12,PKSDDTH=4,CNTTH=8,PKSIDEDTH=6, PKSDDCOLLTH=6,ULSS=N_1_8,ULSRP=1,MATXDLTSX=1-25,PWRPFACH=(-3), SNRIMPRETH=0.0,PRIDLFG=0,INTTHDL=(-115),INTTHUL=(-120),INTULAVP=1, INTDLAVP=1,PRIUDPUL=1,PRIUDPDL=1,ULSIRACST=TRUE, ULDCAST=TRUE,DLDCAST=TRUE,FACCHQTD=5,SCCPCHDESC=4-0-5, UPPTSRXPL=(-110), SSUPPTS=INCR_BY_1DB,MANOUSRTS=n_16,PRACH- DESC=1-0-0-0,PFACHDESC=4-0,UETSCPMA=(-17),PREFPRIO=DEFAULT, MIULPRI=25, MIDLPRI=25,MIULPRIHO=25,MIDLPRIHO=25, TSPRILVBOUN=80-60-40-20,TDNCCPERMI=0,PLMNP=4,DLBFTH=N_03_16, DONDLPCTH=N_09_16,DONULPCTH=N_07_16,DONULSCTH=N_07_16, DLSIRACST=TRUE,EEXCDIST=TRUE,PKAVDRELTH=15, A30808-X3247-L230-3-7619 321 Commands Base Station Controller CML:BSC SYNC1LDAVS=192,EXCDISTTD=30000,MASONLYC=0,HREFRLDTH=1, PRIULFG=2,RXPWRDES=(-110.5),TXPPCCPCH=23,MARINTDL=0, MATXULTSX=33, PCCPCHDESC=1-0-0,BTSHSCSD=FALSE,MACRADIUS=60, PATHLSLOPE=N_0-N_0,BCIDLERESTH=50, CPPFAC=0, EXTMEPROCCLER=FALSE-FALSE-FALSE, MODLUPDMIPER=20, PKNWK=10, LCBM0=NULL,LCBM1=NULL, LCBM2=NULL, LCBM3=NULL,NFRAMEPG=2,MARACHTRANS=MAX_1_RETRANSM,TXINT=4, MASY1RETS=MAX_1_RETRANSM,T3126=63,UETXPMACC=2, CELLBARR=FALSE,CREALL=NOTALLOWED,NALLWACC=na0, SMSCBUSE=TRUE,IMSIATDT=FALSE,T3212=0, EARCLM=TRUE,EC=FALSE, T200TD=44-31-41-90-90-90, TSYNC=1000,TSYNCDL=400,TSYNCUL=400, TSYNCR=400,TTRAU=1000, T3101=HLFSEC-6,T3109=HLFSEC-24, T3111=HLFSEC-1,T3208=10, ENANCD=DISABLED,NCDP1=H8-6,NCDP2=H21- 30,DWPTSCANAINTEX=4; SHUTDOWN BTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD SHUTDOWN BTSTD Applicability: Phase 2. Visibility level 1. Command Description: This command allows the graceful transition of an object from the administrative state "Unlocked" to the administrative state "Locked" after the object has terminated its current activity. The BSS is able to force a mobile station to perform an intercell or inter-BSC HO by means of the O&M SHUTDOWN command. After the SHUTDOWN command is entered, the system tries to perform an intercell or inter-BSC HO per mobile station; in case of failure, a further attempt is performed every 30 seconds for the next 5 minutes period. If after the predefined period (5.5 minutes) the current activity is not terminated, the administrative state will be set at Locked. If one of the objects is still active or busy after the predefined period, ongoing calls will be dropped. Validity ranges of the object addresses "btsmtdn" and "btstdn" can be found in Appendix A. System Responses: SHUTDOWN BTSTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn; SHUTDOWN BTSTD ACK: SHUTDOWN BTSTD NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE 322 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. If the operator has started too many shutdown commands, the system will display the SM TOO BUSY message. 2. Possible state transitions and timing: a) UNLOCKED -immediately-> SHUTTING DOWN ---------- immediately ----------> LOCKED b) UNLOCKED -immediately-> SHUTTING DOWN ---------- 5.5 minutes ----------> LOCKED c) UNLOCKED -immediately-> SHUTTING DOWN ---------- after object went to idle state ----------> LOCKED The state changes described above show all the possible transitions when the shut- down command was performed. The rst column of the table gives the situations which are affected by doing a shut- down of an object. Example of Command Execution Shutdown BTSTD:NAME=BTSMTD:0/BTSTD:0; UNLOCK BTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD UNLOCK BTSTD Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state "Unlocked". Validity ranges of the object addresses "btsmtdn" and "btstdn" can be found in Appendix A. The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SITUATIONS TRANSITIONS FORCED/NOT FORCED idle object a) busy object but not released after the SHUTDOWN command b) busy object but released after the SHUTDOWN command c) UNLOCK BTSTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn; A30808-X3247-L230-3-7619 323 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Unlock BTSTD:NAME=BTSMTD:0/BTSTD:0; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. 324 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller CBCL The CBCL object represents the link which connects the RC, through the IXLT, to the BSC with X.25 protocol. CREATE CBCL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CBCL CREATE CBCL Applicability: Phase 2. Visibility level 2. Command Description: This command adds the object CBCL that represents the logical link for the communi- cation with CBC. The validity range of the object address "cbcln" can be found in Appendix A. System Responses: CREATE CBCL: NAME=CBCL:cbcln [,LINKTYPE=] ,[X121ADDR=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The X25A/X25D (depending on LINKTYPE) object instance must be already equipped. The IPLI object must be already equipped if the operator sets LINKTYPE attribute to the value IPLI. UNSUCCESSFUL_COPY_ZERO_NOTEQUIPPED The creation of copy #1 is subordinated to the presence of copy #0. UNSUCCESSFUL_INVALID_ATTRIBUTES The X121ADDR attribute must be set to a value different from NULL if LINKTYPE attribute is set to X25A/X25D. The X121ADDR attribute cannot be set to a value different from NULL if LINKTYPE attribute is set to IPLI UNSUCCESSFUL_VAR_OUT_OF_RANGE Only one CBCL instance (CBCL:0) can be equipped if the LINKTYPE attribute is set to IPLI. A30808-X3247-L230-3-7619 325 Commands Base Station Controller CML:BSC Application Guidelines: After the creation of the object, the ADMINISTRATIVE state of this object is set at UNLOCKED. The UNLOCK command is NOT required to put this object in service. Example of Command Execution Create CBCL:NAME=CBCL:0,LINKTYPE=X25A, X121ADDR=956712345123451234512345123451234; DELETE CBCL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CBCL DELETE CBCL Applicability: Phase 2. Visibility level 2. Command Description: This command deletes the CBCL object. The validity range of the object address "cbcln" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete CBCL:NAME=CBCL:0; DELETE CBCL: NAME=CBCL:cbcln; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a CBCL, the relative object instance must be in LOCKED state. UNSUCCESSFUL_COPY_ONE_EQUIPPED The deletion of the instance #0 is possible only if the copy #1 is not present. 326 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET CBCL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CBCL GET CBCL Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the parameters of the CBCL object. The validity range of the object address "cbcln" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get CBCL:NAME=CBCL:0,REQATTL=CBCLTYPE&LINKTYPE&X121ADDR; GET CBCL BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CBCL GET CBCL BASICS Applicability: Phase 2. Visibility level 0. GET CBCL: NAME=CBCL:cbcln [,REQATTL=CBCLTYPE, LINKTYPE=, X121ADDR=]; GET ACK: CBCLTYPE: cbclType LINKTYPE: linkType X121ADDR: X121Addr GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET CBCL BASICS: NAME=CBCL:cbcln; A30808-X3247-L230-3-7619 327 Commands Base Station Controller CML:BSC Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "cbcln" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get CBCL BASICS:NAME=CBCL:0; GET CBCL STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CBCL GET CBCL STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the CBCL object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "cbcln" can be found in Appendix A. System Responses: GET ACK: CBCLTYPE: cbclType LINKTYPE: linkType X121ADDR: X121Addr GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET CBCL STAT: NAME=CBCL:cbcln; GET CBCL STAT ACK: GET CBCL STAT NACK: NACK CAUSES: 328 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: The handling of the status attributes may be summarized as follows: The operational state handling may be summarized as follows: Example of Command Execution Get CBCL STAT:NAME=CBCL:0; UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. Value CBCL standby PROVIDING SERVICE not used HOTSTANDBY not used COLDSTANDBY not used NULL_STATUS not used availability FAILED CBCL DISABLED layer 3 is down DEGRADED not used OFF_DUTY not used DEPENDENCY X25A/X25D is DISABLED or LOCKED procedural INITIALIZING not used Tab. 2.2 Status of attribute handling CBCL ENABLED layer 3 up DISABLED layer 3 down Tab. 2.3 Operational state handling A30808-X3247-L230-3-7619 329 Commands Base Station Controller CML:BSC GET CBCLX25INFO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CBCL GET CBCL X25INFO Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve information about a X25 CBCL link. The validity range of the object address "cbcln" can be found in Appendix A. System Responses: Application Guidelines: None Example of Command Execution Get CBCL X25INFO:NAME=CBCL:0; GETRELATIONSHIP CBCL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CBCL GETRELATIONSHIP CBCL Applicability: Phase 2. Visibility level 1. GET CBCL X25INFO: NAME=CBCL:cbcln; GET CBCL X25INFO ACK: GET CBCL X25INFO NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETRELATIONSHIP CBCL: NAME=CBCL:cbcln; 330 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of the all HMOs (Hardware Managed Object) supporting the FMO functionality. For the CBCL object the related HMOs are the following: IXLT, EPWR, PWRD, MPCC and either X25D(for direct CBC/BSCconnection) or X25A, LICD/LICDS, TDPC, MEMT, NTW+ BSMS, TPWR (for CBC/BSC connection via A interface). The validity range of the object address "cbcln" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship CBCL:NAME=CBCL:0; LOCK CBCL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CBCL LOCK CBCL Applicability: Phase 2. Visibility level 1 Command Description: This command allows to set an object at the administrative state "Locked". The validity range of the object address "cbcln" can be found in Appendix A. System Responses: GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The object does not provide any relationship attribute. LOCK CBCL: NAME=CBCL:cbcln; LOCK CBCL ACK: LOCK CBCL NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE A30808-X3247-L230-3-7619 331 Commands Base Station Controller CML:BSC Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock CBCL:NAME=CBCL:0; UNLOCK CBCL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CBCL UNLOCK CBCL Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state "Unlocked". The validity range of the object address "cbcln" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock CBCL:NAME=CBCL:0; The object instance is in administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNLOCK CBCL: NAME=CBCL:cbcln; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 332 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller A30808-X3247-L230-3-7619 333 Commands Base Station Controller CML:BSC CHAN The CHAN object represents the radio time slot in which the radio carrier is subdivided into time sharing; it can be differently configured depending on its usage for the telephone application software (full rate or half rate traffic channels, dedicated or common control channels). CREATE CHAN Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CHAN CREATE CHAN Applicability: Phase 2. Visibility level 2. Command Description: This command defines a Physical Radio Channel by specifying its attributes which allow to map Logical Channels onto Physical Radio Channels. Validity ranges of the object addresses btsmn, "btsn", "trxn" and "rtsln" can be found in Appendix A. System Responses: CREATE CHAN: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn/CHAN:chann ,CHTYPE= [,FHSYID=] [,MAIO=] [,TSC=] [,EXTMODE=] [,GDCH=] [,CHPOOLTYP=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The TRX which the channel belongs to must be equipped. FHSY instance pointed by CHAN instance is not equipped. UNSUCCESSFUL_BROADCAST_CHAN_NOTEQUIPPED The channel type of the first channel created in the BTS must be MAINBCCH, MBCCHC or BCBCH. UNSUCCESSFUL_INVALID_TIME_SLOT Make reference to Application Guidelines n. 1, n. 18, n. 22, n. 39, n. 41. 334 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller UNSUCCESSFUL_INVALID_CHAN_TYPE Make reference to Application Guidelines n. 2, n. 3, n. 4, n. 6, n. 10, n. 17, n. 21, n. 22, n. 23, n. 24, n. 29, n. 30, n. 35, n. 37. UNSUCCESSFUL_FREQ_OUT_OF_RANGE If the channel type is SDCCH or SCBCH and the "sysIndicator" attribute (see BTS object) is EXT900, then the TRX carrier frequency must belong to the BB900 frequency band. UNSUCCESSFUL_TIME_SLOT_ZERO_ALLOCATION The tsln 0 of a pcmb line is used for synchronism. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. For more details see Application Guidelines n. 5, n. 9, n. 25, n. 26, n. 33, n. 38, n. 40. UNSUCCESSFUL_NO_MORE_SMSCBCH_ALLOWED Make reference to Application Guideline n. 8. UNSUCCESSFUL_HOPPING_ACTIVE Make reference to Application Guideline n. 10. UNSUCCESSFUL_NO_MORE_FREQ_AVAILABLE If the FHSYID is equal to 0 frequency hopping must be disabled (ENHOPP parameter of the BTS object). Make reference to Application Guideline n. 30. UNSUCCESSFUL_INVALID_MAIO Make reference to Application Guidelines n. 12, n. 13, n. 24, n. 28. UNSUCCESSFUL_INVALID_HOPP_GROUP Make reference to Application Guidelines n. 14, n. 15, n. 24, n. 28. UNSUCCESSFUL_OVERLAP_BAND When the frequency band of the BTS is EXT900 the channel can use only the Frequency Hopping sequence in the same band (base or extended) of the superordinate TRX. HOPPING_NOT_ALLOWED In case of synthesizer frequency hopping, it is not allowed to set the FHSYID of the channel subordinated to the broadcast TRX at a value different from 0. If the channel is a PBCCH, it cannot be set to hopping mode. PREVIOUS_CHAN_DOUBLE The previous timeslot supports a channel in Extended Mode. HSCSD_HOPP_INCONSISTENT Make reference to Application Guidelines n. 31 and n. 32. HSCSD_TSC_INCONSISTENT Make reference to Application Guideline n. 31. GPRS_TSC_INCONSISTENT All the traffic channels subordinated to a TRX with GSUP set at TRUE must have the same TSC. GPRS_HOPP_INCONSISTENT A30808-X3247-L230-3-7619 335 Commands Base Station Controller CML:BSC Application Guidelines: 1. If the channel type is MAINBCCH, MBCCHC, BCBCH, CCCH, SCBCH or SDCCH (i.e. control channels) then no time slots must be allocated on the pcmb line. 2. If the channel type is MAINBCCH, BCBCH or MBCCHC, then rtsln must be 0. 3. If the channel type is MAINBCCH, BCBCH, MBCCHC or CCCH then the TRX the channel belongs to must be the broadcast one. 4. If the channel type is MBCCHC or BCBCH, then the parameter NBLKACGR (noOfBlocksForAccessGrant), which indicates the number of TDMA frames reserved for the Access Grant channel during a period of 51 TDMA frames, must be lower than 2; the NBLKACGR parameter is set by the SET BTS command and its default value is "0". 5. If the channel type is MAINBCCH, MBCCHC, BCBCH, CCCH, SCBCH, SDCCH or TCH/SDthen the attribute TSCmust be equal to the BCCattribute (see BTS object). 6. The channel CCCHcannot be created if the MBCCHCor BCBCHhave already been congured. The rst CCCH channel must be created on rtsln = 2; the second CCCH channel must be created on rtsln = 4; the third CCCH channel must be created on rtsln = 6. 7. After the creation of the CHAN object, the ADMINISTRATIVE state of this object is set at LOCKED. An UNLOCK command is required to put this object in service. 8. Only one BCBCH or SCBCH can be created in a BTS. 9. If FHSY is either equal to 0 or SKIPPED then MAIO is SKIPPED. If FHSY > 0 then MAIO is NOT SKIPPED. 10. If the channel type is MAINBCCH, MBCCHC, BCBCH or CCCH then the FHSYID must be equal to 0. 11. The number of channels, with the same time slot number, pointing to the same FHSY instance can not be greater than the number of frequencies in the mobile allo- cation of the frequency hopping law. 12. CHAN instances, with the same time slot number, pointing to the same FHSY instance must have different values for MAIO attribute. 13. The value for MAIO attribute must be less than the number of frequencies in the mobile allocation of the FHSY instance used. 14. CHAN instances, with the same time slot number, can not point to different FHSY instances if the two FHSY instances use the same frequencies. If the TRX has the GSUP set at TRUE single TCHs must have the same FHSYIDand MAIO, and if one or more CCCHs have already been equipped the channels cannot hop (i.e. FHSYD attribute must be 0). INVALID_COMMAND Only one PBCCH can be allocated. A PCCCH can be allocated only if the PBCCH is already equipped. UNSUCCESSFUL_NOT_ENOUGH_SUBTSLB_AVAILABLE If the SWversion running on the superordinate BTSMbelongs to BR6.0 release (see EXPSWV parameter description), namely Abis allocation is static, the CREATE CHAN command is accepted only if at least one free SUBTSLB (not associated to any CHAN) on a PCMB connecting the BTSM exists. 336 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 15. It is not possible to have one CHAN instance with FHSYID = 0 and another CHAN instance, with the same time slot number, pointing to a FHSY instance, if the carrier frequency of superordinate TRX of the rst channel is included in the mobile allocation of FHSY instance pointed by the second. 16. The SCBCH channel can be equipped only on time slots 1, 2, 3 of the BCCH-TRX. 17. If the channel type is SCBCH then the parameter NBLKACGR (noOfBlocksForAccessGrant attribute, set by the SET BTS command) must not be equal to 0. 18. When the frequency band of the BTS is EXT900 the channel can use only the Frequency Hopping sequence in the same band (base or extended) of the superordinate TRX. 19. The creation of a CHAN causes a temporary loss of service for the whole TRX because of a reset of the associated BBSIG. It is suggested to shutdown the TRX before creating one or more channels to avoid that calls are dropped. 20. Creation of TCHF_HLF channels must be compatible with the type of hardware used for TRAU equipment. Only TRAC V3 boards can handle half rate channels coding- decoding feature. 21. No more than other three channels containing SDCCH subchannels (i.e. MBCCHC, BCBCH, SCBCH, SDCCH) must belong to the same transceiver. 22. If any channel containing SDCCH subchannels is equipped on a BTS, then at least one of them must be on the BCCH-TRX. 23. In case of concentric cell the SDCCH channels cannot be created on TRXs with trxArea parameter set at INNER. 24. In case of concentric cell and base band hopping selected, the attribute FHSYID of a channel subordinated of a INNER TRX cannot be set with the frequency hopping system that use frequencies of complete area (and viceversa). 25. If cellType attribute values EXTCELL all the control and signalling channels must have EXTMODE=TRUE. If cellType attribute is different fromEXTCELL the EXTMODE attribute cannot be set at TRUE. 26. The radio timeslot number (rtsln) of an extended channel must be an even one. 27. The timeslot following an extended channel must be not equipped. 28. The extended channels use two consecutive timeslots: therefore, in case of extended cell, all the previous Application Guidelines regarding frequency hopping consistency apply also to the timeslot following the channel timeslot. 29. The creation of a SCBCH on a TRX different from BCCH-TRX is allowed only if the CELLTYPE attribute of the BTS object is set at EXTCELL and at least one CCCH and one SDCCH have already been congured. 30. It is not allowed to congure the third CCCH channel if the CELLTYPE attribute of the BTS object is set at EXTCELL. 31. If the HSCSD service is activated at BTS side (i.e. attribute BTSHSCSD of BTS object set at TRUE) the following requirements must be satised: Case Base Band Hopping Mode: on a given TRX, single TCHs, on timeslots from 1 to 7, must have the same FHSYID, MAIO and TSC and if one or more CCCHs have already been equipped, channels on the BCCH-TRX can not hop (i.e. FHSYID attribute must be 0). Case Synthesizer Hopping Mode: on a given TRX, different from the BCCH one, all single TCHs must have the same FHSYID, MAIO and TSC. The same conguration rules apply also to GPRS. 32. In a cell with Base Band Hopping Mode, if the HSCSD service is activated at BTS side (attribute BTSHSCSD of BTS object set at TRUE), the rst CCCH channel A30808-X3247-L230-3-7619 337 Commands Base Station Controller CML:BSC cannot be created if the MOBALLOC attribute of some FHSY object instances contains the BCCH frequency and if some channels equipped in the BCCH-TRX is hopping (i.e. FHSYID is different from 0). 33. Compatibility between CHTYPE and ASCISER: if ASCISER is equal to VBSENABLED or VGCSENABLED or VBS_VGCSENABLED: 34. A TCH channel type can be created if at least one of the following conditions is satised: a SDCCH channel type already exists; a channel type containing a SDCCH (e.g. a MBCCHC, BCBCH or SCBCH) already exists. 35. The PBCCH and PCCCH channels must be created on the BCCH-TRX only. The PBCCH and PCCCH conguration is allowed only for the channel types TCHFULL and TCHF_HLF as well as TCHSD created with pool type TCHPOOL. 36. All channels on BCCH-TRX must have the same TSC (Training Sequence Code) for every GPRS activation status (activated or not). 37. GPRS is not supported in the outer area of an extended cell: if the channel is a GPRS one (PBCCH, PCCCH) than the EXTMODE parameter cannot be set at TRUE. The inner area of an extended cell supports GPRS. 38. At the creation of a GPRS channel (PBCCH, PCCCH) the GSUP ag of the related TRX must be already set at TRUE. On BCCH TRX the operator can create no more than 5 GPRS channels. 39. If the EEOTD parameter (see BTS object) is set at TRUE, the TSC value can only be NULL. 40. A TCHSD channel, with CHPOOLTYP equal to TCHSDPOOL, cannot be used for GPRS/EDGE trafc. The suggestion is to equip the TCH/SD channels of the mixed pool at the extreme positions inside the TRX (either TS7 or immediately after the control channels, or TS0 in the not-BCCH carrier). If multiple TCH/SD (mixed pool) are requested, they have to be equipped adjacent with the same criteria in grouping the channels. Example of Command Execution Create CHAN:NAME=BTSM:0/BTS:0/TRX:0/CHAN:0,CHTYPE=TCHFULL, FHSYID=0,MAIO=0,TSC=2,EXTMODE=FALSE,GDCH=PBCCH, CHPOOLTYP=TCHSDPOOL; NOCHFBLK NOCHBLKN CHTYPE 1..4 1..4 5 1..3 MAINBCCH 6 1..2 7 1 1..3 1 MBCCHC or BCBCH 338 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DELETE CHAN Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CHAN DELETE CHAN Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a Radio Channel previously created through the CREATECHAN command. Validity ranges of the object addresses btsmn, "btsn", "trxn" and "rtsln" can be found in Appendix A. System Responses: Application Guidelines: 1. If rtsln = 2 and the channel type is CCCH, then it is rst necessary to delete the other CCCH in the TRX; if rtsln = 4 and the channel type is CCCH then it is rst necessary to delete the CCCH on rtsln = 6 of the same TRX. DELETE CHAN: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn/CHAN:rtsln; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a CHAN, the relative object instance must be in LOCKED state. INVALID_COMMAND Make reference to Application Guidelines n. 1, n. 3, n. 4, n. 5, n. 6, n. 7, n. 8. UNSUCCESSFUL_SMSCB_USED The SCBCH and BCBCH channels can be deleted only if the SMSCBUSE parameter is set at FALSE (SMSCBUSE parameter of the BTS object). UNSUCCESSFUL_HOPPING_ACTIVE The last hopping channel can be deleted only if hopping is disabled (ENHOPP parameter of the BTS object set at FALSE). A30808-X3247-L230-3-7619 339 Commands Base Station Controller CML:BSC 2. The deletion of a CHAN causes a temporary loss of service for the whole TRX because of a reset of the associated BBSIG. It is suggested to shutdown the TRX before deleting one or more channels to avoid that calls are dropped. 3. The last channel including some SDCCH subchannels equipped on the BCCH-TRX cannot be deleted if any other SDCCH is equipped on a different TRX on the same BTS. 4. The last extended or not extended TCH channel cannot be deleted if the intracell handover for extended cell (attribute EXTCHO of HAND object) is enabled. 5. The broadcast channel cannot be deleted if there are other channels equipped in the BTS. 6. It is not possible to delete a CCCH channel in an EXTENDED cell with SCBCH channel equipped. 7. The last SDCCH cannot be deleted if there are trafc channels equipped in the cell. 8. A PBCCH cannot be deleted if some PCCCHs are allocated. Example of Command Execution Delete CHAN:NAME=BTSM:0/BTS:0/TRX:0/CHAN:0; GET CHAN Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CHAN GET CHAN Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the parameter values of a CHAN previously created through the CREATE CHAN command. Validity ranges of the object addresses btsmn, "btsn", "trxn" and "rtsln" can be found in Appendix A. System Responses: GET CHAN: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn/CHAN:rtsln [,REQATTL=CHTYPE, FHSYID, MAIO, TSC, EXTMODE, GDCH, CHPOOLTYP]; GET ACK: NAME: name CHTYPE: channelCombination FHSYID: frequencyHoppingID MAIO: maio TSC: trainingSequenceCode EXTMODE: extendedMode GDCH: gprsDedicatedChannel 340 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get CHAN:NAME=BTSM:0/BTS:0/TRX:0/CHAN:0,REQATTL=CHTYPE& FHSYID&MAIO&TSC&EXTMODE&GDCH&CHPOOLTYP; GET CHAN BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CHAN GET CHAN BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses btsmn, "btsn", "trxn" and "rtsln" can be found in Appendix A. System Responses: CHPOOLTYP: channelPoolType GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET CHAN BASICS: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn/CHAN:rtsln; GET ACK: NAME: name CHTYPE: channelCombination FHSYID: frequencyHoppingID MAIO: maio TSC: trainingSequenceCode EXTMODE: extendedMode GDCH: gprsDedicatedChannel CHPOOLTYP: channelPoolType GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 341 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get CHAN BASICS:NAME=BTSM:0/BTS:0/TRX:0/CHAN:0; GET CHAN STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CHAN GET CHAN STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the CHAN object: Administrative State (AST) Operational State (OST) Usage State (UST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). Validity ranges of the object addresses btsmn, "btsn", "trxn" and "rtsln" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get CHAN STAT:NAME=BTSM:0/BTS:0/TRX:0/CHAN:0; GET CHAN STAT: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn/CHAN:rtsln; GET CHAN STAT ACK: GET CHAN STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 342 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETRELATIONSHIP CHAN Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CHAN GETRELATIONSHIP CHAN Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO(Functional Managed Object); the relationship information consists of all the HMOs (Hardware Managed Object) supporting the FMO functionality. For the CHAN object the related HMOs are the following: LICD/LICDS, EPWR, PPLD, PWRD, MPCC, TDPC, MEMT, NTW, PPXL and all the BTSE HMOs that implement the TRX functionality for a certain BTS. For BS-2x/6x, the BTSE HMOs are: ACOM, BBSIG, CCLK, CCTRL, FTNF, FVSWR, GPSU, LI, PA, RXMUCO, RXAMOD and TPU. For BS-4x/240/241/240XL, the BTSEHMOs are: COBA, COSA, CU, DIDCTMA, DILNA, DUDCTMA, DULNA, DUVSWR, FVSWRP, FTNFP and TMA. For BS-242, the BTSE HMOs are: CA, CCINT, CCSLINK, COBA, COSA and DCREFE. For the BS-82, the BTSE HMOs are: COBA, CU, DUVSWR and DULNA. Validity ranges of the object addresses btsmn, "btsn", "trxn" and "rtsln" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship CHAN:NAME=BTSM:0/BTS:0/TRX:0/CHAN:0; GETRELATIONSHIP CHAN: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn/CHAN:rtsln; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. A30808-X3247-L230-3-7619 343 Commands Base Station Controller CML:BSC GETSUBO CHAN Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CHAN GETSUBO CHAN Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. Validity ranges of the object addresses btsmn, "btsn", "trxn" and "rtsln" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo CHAN:NAME=BTSM:0/BTS:0/TRX:0/CHAN: 0; LOCK CHAN Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CHAN LOCK CHAN Applicability: Phase 2. GETSUBO CHAN: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn/CHAN:rtsln; GETSUBO CHAN ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end a message is displayed notifying the end of the subordinate list. GETSUBO CHAN NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK CHAN: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn/CHAN:rtsln; 344 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". Validity ranges of the object addresses btsmn, "btsn", "trxn" and "rtsln" can be found in Appendix A. System Responses: Application Guidelines: 1. If object TRX or CHAN is locked, calls using the concerned objects are dropped. To avoid loss of calls by locking objects TRX or CHAN a request for usage state of this objects should be done previously (e.g. GET state status). In case returned usage state is "active" or "busy" locking should not be done (otherwise calls are dropped). 2. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 3. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). 4. If all trafc channels of a cell are locked, the BSC barres the cell for further access: the parameter Cell Barred For Access in System Information is set at cell barred. 5. It is recommended to lock a channel congured as CCCH(by means of the CHTYPE parameter) only the time strictly necessary to perform conguration change, and to return it in service as soon as possible.The reason is that the LOCK of a CCCH CHAN does not foresee the reconguration of CCCH groups on remaining CCCHs available. So, when a CCCH is locked, a MS of the corresponding CCCH group can perform originating calls but cannot response to terminated calls because the Paging message is not sent on the LOCKED CCCH. Example of Command Execution Lock CHAN:NAME=BTSM:0/BTS:0/TRX:0/CHAN:0; LOCK CHAN ACK: LOCK CHAN NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 345 Commands Base Station Controller CML:BSC SET CHAN Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CHAN SET CHAN Applicability: Phase 2. Visibility level 2. Command Description: This command modifies the attributes of a Physical Radio Channel previously created through the CREATE CHAN command. Validity ranges of the object addresses btsmn, "btsn", "trxn" and "rtsln" can be found in Appendix A. System Responses: SET CHAN: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn/CHAN:chann [,FHSYID=] [,MAIO=] [,TSC=] [,GDCH=] [,CHPOOLTYP=]; SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. For more details see Application Guidelines n. 1, n. 2, n. 3, n. 15. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The FHSY object instance must be already equipped. UNSUCCESSFUL_HOPPING_ACTIVE The attributes FHSYID and MAIO can be modified only if the Frequency Hopping is disabled (ENHOPP parameter of the BTS object must be FALSE). UNSUCCESSFUL_NO_MORE_FREQ_AVAILABLE The number of channels, with the same time slot number, pointing to the same FHSY instance can not be greater than the number of frequencies in the mobile allocation of the frequency hopping law. Make reference to Application Guideline n. 9. UNSUCCESSFUL_INVALID_HOPP_GROUP Make reference to Application Guidelines n. 4, n. 5, n. 8, n. 9. UNSUCCESSFUL_INVALID_STATUS Make reference to Application Guidelines n. 6 and n. 7. 346 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. If the channel type is MAINBCCH, MBCCHC, BCBCH, CCCH, SCBCH, SDCCH or TCH/SD (i.e. control channels) then the attribute TSC must be equal to the BCC attribute (see BTS object). 2. The nal value for FHSYID and MAIO must belong to one of the following cases: FHSYID = 0, MAIO = 0 FHSYID > 0, MAIO = 0-63. 3. If the channel type is MAINBCCH, MBCCHC, BCBCH or CCCH, the FHSYID must be equal to 0. 4. CHAN instances, with the same time slot number, pointing to the same FHSY instance must have different values for MAIO attribute. 5. The value for MAIO attribute must be less than the number of frequencies in the mobile allocation of the FHSY instance used. 6. To modify the TSC attribute the CHAN must be put in the locked state. 7. The FHSYID attribute can be modied from 0 to different from 0 value only if the channel is locked. The FHSYID attribute can be modied fromdifferent from0 value to different from 0 value only if the two frequency hopping systems have the same HSN, otherwise the channel must be put in locked state. 8. In case of concentric cell and base band hopping selected, the attribute FHSYID of a channel subordinated of a INNER TRX cannot be set with the frequency hopping system that use frequencies of complete area (and viceversa). UNSUCCESSFUL_OVERLAP_BAND When the frequency band of the BTS is EXT900 the channel can use only the Frequency Hopping sequence in the same band (base or extended) of the superordinate TRX. HOPPING_NOT_ALLOWED In case of synthesizer frequency hopping, it is not allowed to set the FHSYID of the channel subordinated to the broadcast TRX at a value different from 0. If the channel is a PBCCH, it cannot be set to hopping mode. HSCSD_HOPP_INCONSISTENT Make reference to Application Guideline n. 10. HSCSD_TSC_INCONSISTENT Make reference to Application Guideline n. 11. UNSUCCESSFUL_INVALID_CHAN_TYPE Make reference to Application Guidelines n. 12, n. 13. GPRS_TSC_INCONSISTENT All channels on BCCH-TRX must have the same TSC (Training Sequence Code) for every GPRS activation status (activated or not). GPRS_HOPP_INCONSISTENT If the TRX has the GSUP set at TRUE single TCHs must have the same FHSYD and MAIO and if one or more CCCHs have already been equipped, the channels cannot hop (i.e. FHSYD attribute must be 0). INVALID_COMMAND Only one PBCCH can be allocated. A PBCCH can be allocated only if the PBCCH is already equipped. A30808-X3247-L230-3-7619 347 Commands Base Station Controller CML:BSC 9. The extended channels use two consecutive timeslots: therefore, in case of extended cell, all the previous Application Guidelines regarding frequency hopping apply also to the timeslot following the channel timeslot. 10. If the HSCSD service is activated at BTS side (i.e. attribute BTSHSCSD of BTS set as TRUE) the following requirements must be satised: Case Base Band Hopping Mode: on a given TRX, single TCHs, on timeslot from 1 to 7 must have the same FHSYID and MAIO and if one or more CCCH have already been equipped, channels on the BCCH-TRX cannot hop (i.e. FHSYID attribute must be 0). Case Synthesizer Hopping Mode: on a given TRX different from the BCCH one, all single TCHs must have the same FHSYID and MAIO. 11. If the HSCSD service is activated at BTS side (i.e. attribute BTSHSCSD of BTS set as TRUE) the following TSC requirements must be satised: Case Base Band Hopping Mode: on a given TRX, single TCHs on timeslot from 1 to 7 must have the same TSC. Case Synthesizer Hopping Mode: on a given TRX all single TCHs must have the same TSC. 12. The PBCCH and PCCCH channels must be created on the BCCH-TRX only. The PBCCH and PCCCH conguration is allowed only for the channel types TCHFULL and TCHF_HLF as well as TCHSD created with pool type TCHPOOL. 13. GPRS is not supported in the outer area of an extended cell: if the channel is a GPRS one (PBCCH, PCCCH) than the EXTMODE parameter cannot be set at TRUE. The inner area of an extended cell supports GPRS. 14. If the EEOTD parameter (see BTS object) is set at TRUE, the TSC value can only be NULL. 15. If the GDCH attribute is set at a value different from NULL (PBCCH, PCCCH) the GSUP ag of the related TRX should be already set at TRUE. 16. A TCHSD channel, with CHPOOLTYP equal to TCHSDPOOL, cannot be used for GPRS/EDGE trafc. The suggestion is to equip the TCH/SD channels of the mixed pool at the extreme positions inside the TRX (either TS7 or immediately after the control channels, or TS0 in the not-BCCH carrier). If multiple TCH/SD (mixed pool) are requested, they have to be equipped adjacent with the same criteria in grouping the channels. Example of Command Execution Set CHAN:NAME=BTSM:0/BTS:0/TRX:0/CHAN:0,FHSYID=<DEFAULT>, MAIO=<DEFAULT>,TSC=2,GDCH=PBCCH,CHPOOLTYP=TCHSDPOOL; SHUTDOWN CHAN Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CHAN SHUTDOWN CHAN Applicability: Phase 2. SHUTDOWN CHAN: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn/CHAN:rtsln; 348 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Visibility level 1. Command Description: This command allows the graceful transition of an object from the administrative state "Unlocked" to the administrative state "Locked" after the object has terminated its current activity. The BSS is able to force a mobile station to perform an intracell, intercell or inter-BSC HO by means of the O&MSHUTDOWN command. After the SHUTDOWN command is entered, the system tries to perform an intracell, intercell or inter-BSC HO per mobile station; in case of failure, a further attempt is performed every 30 seconds for the next 5 minutes period. If after the predefined period (5.5 minutes) the current activity is not terminated, the administrative state will be set at Locked. If one of the objects is still active or busy after the predefined period, ongoing calls will be dropped. Validity ranges of the object addresses btsmn, "btsn", "trxn" and "rtsln" can be found in Appendix A. System Responses: Application Guidelines: 1. If the operator has started too many shutdown commands, the system will display the SM TOO BUSY message. 2. Possible state transitions and timing: a) UNLOCKED -immediately-> SHUTTING DOWN ---------- immediately ----------> LOCKED b) UNLOCKED -immediately-> SHUTTING DOWN ---------- 5.5 minutes ----------> LOCKED c) UNLOCKED -immediately-> SHUTTING DOWN ---------- after object went to idle state ----------> LOCKED The state changes described above show all the possible transitions when the shut- down command was performed. The rst column of the table gives the situations which are affected by doing a shutdown of an object. SHUTDOWN CHAN ACK: SHUTDOWN CHAN NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SITUATIONS TRANSITIONS FORCED/NOT FORCED idle object a) busy object but not released after the SHUTDOWN command b) busy object but released after the SHUTDOWN command c) A30808-X3247-L230-3-7619 349 Commands Base Station Controller CML:BSC Example of Command Execution Shutdown CHAN:NAME=BTSM:0/BTS:0/TRX:0/CHAN:0; UNLOCK CHAN Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CHAN UNLOCK CHAN Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". Validity ranges of the object addresses btsmn, "btsn", "trxn" and "rtsln" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock CHAN:NAME=BTSM:0/BTS:0/TRX:0/CHAN:0; UNLOCK CHAN: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn/CHAN:rtsln; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 350 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller CPEX The CPEX (Control Panel and External alarms device) is the card which reports to MPCC 16 external alarms and the FAN alarm and controls the fuse and alarm panel. It is redounded 1 + 1. GET CPEX STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE CPEX GET CPEX STAT Applicability: Phase 2. Visibility level 0. Command Description This command is used to retrieve the following State/Status attributes related to the CPEX object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CST) Unknown Status (UNK). The validity range of the object address "cpexn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get CPEX STAT:NAME=CPEX:0; GET CPEX STAT: NAME=CPEX:cpexn; GET CPEX STAT ACK: GET CPEX STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 351 Commands Base Station Controller CML:BSC GETRELATIONSHIP CPEX Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE CPEX GETRELATIONSHIP CPEX Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected HMO (Hardware Managed Object); the relationship information consist of all the FMOs (Functional Managed Object) using the HMO service. This information is included in the RELATED_FUNCTIONAL_OBJECTS attribute (ATTID parameter) and the attribute value depends on the working state of the target HMO. The validity range of the object address cpexn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship CPEX:NAME=CPEX:0,ATTID=RELATED_FUNCTIONAL_OBJECTS; GETSUBO CPEX Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE CPEX GETSUBO CPEX GETRELATIONSHIP CPEX: NAME=CPEX:cpexn,ATTID=; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected HMO the list of related FMOs is displayed (HMO to FMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. GETSUBO CPEX: NAME=CPEX:cpexn; 352 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "cpexn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo CPEX:NAME=CPEX:0; GETTEST CPEX Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE CPEX GETTEST CPEX Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the values of all the attributes belonging to a specified test object; the test object is created by the systemas a result of a request to start a test and it is deleted when the test terminates. The validity range of the object address "cpexn" can be found in Appendix A. System Responses: GETSUBO CPEX ACK: The output of the command can be composed by one or more pack with a maximumnumber of ten subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GETSUBO CPEX NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETTEST CPEX: NAME=CPEX:cpexn; GETTEST CPEX ACK: GETTEST CPEX:NAME=CPEX:0; name = TEST:<n> A30808-X3247-L230-3-7619 353 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Gettest CPEX:NAME=CPEX:0; LOCK CPEX Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE CPEX LOCK CPEX Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state LOCKED. The validity range of the object address "cpexn" can be found in Appendix A. mOts = CPEX:0 testState = It can assume one of the following values: not_initialized, idle, initializing, suspended, testing, terminating and disabled. testOutcome = It represents the test result: it can be Inconclusive (meaning-less: that is if the phases already executed were successful) or Fail (if at least one of the executed phases failed). testMonitor phaseId = It is a list of the phases to execute and their status that can be: pass, fail, running or waiting. phaseStatus = phaseId = phaseStatus = .... GETTEST CPEX NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. LOCK CPEX: NAME=CPEX:cpexn; 354 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock CPEX:NAME=CPEX:0; PERFTEST CPEX Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE CPEX PERFTEST CPEX Applicability: Phase 2. Visibility level 2. Command Description: This command is used to perform a test on the selected CPEX object; the test consists of the following phases: Accessibility Test (start phase), FAN alarm force (WP1), ENVA alarm force (WP2), End Test (end phase). The validity range of the object address "cpexn" can be found in Appendix A. System Responses: LOCK CPEX ACK: LOCK CPEX NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The selected object is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. PERFTEST CPEX: NAME=CPEX:cpexn; PERFTEST CPEX ACK: PERFTEST CPEX:NAME=CPEX:0; testObject=TEST:<n> The test results will be displayed at the end of the test phases. A30808-X3247-L230-3-7619 355 Commands Base Station Controller CML:BSC Application Guidelines: 1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked" state, if the diagnostic is intrusive. 2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for test" state. When the test result is: "fail" the object goes in Disabled / Failed operational state; "pass" the object goes in Enabled operational state; Result TEST: name = TEST:<n> testOutcome = This field represents the test result; one of the following values can be displayed: Pass all the test phases are successfully performed. Inconclusive the test is aborted by the system or the test is terminated by the operator. Fail if at least one of the executed phases fail. mOts = It is the identifier of the hardware object under test. testTermination = It specifies how the test is terminated, it can assume the following values: Normal all the test phases are performed. Abort the test is aborted by system. Cancel the test is terminated by operator. executedPhases phaseId = It represents the list of the executed test phases (in case of successful test result, all the test phases will be listed). additionalWords = .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases; they are displayed only for test stopped during it execution. phaseId = .... poprosedRepair Action = A list of most probable fail probable causes is shown (max four messages) PERFTEST CPEX NACK: NACK CAUSES: OTHER_TESTS_RUNNING Other incompatible tests are already running or no more parallel execution of tests possible. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. 356 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller "inconclusive" the object returns to the operational state previous to the test or in Enabled operational state. Example of Command Execution Perftest CPEX:NAME=CPEX:0; STOPTEST CPEX Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE CPEX STOPTEST CPEX Applicability: Phase 2. Visibility level 2. Command Description: This command allows to terminate the test previously requested; the test can be in progress or in the waiting list (queued). In the first case the process that executes the diagnostic will be interrupted by executing the end phase; in the second case the test will be removed from the waiting list. The validity range of the object address "cpexn" can be found in Appendix A. System Responses: STOPTEST CPEX: NAME=CPEX:cpexn; STOPTEST CPEX ACK: STOPTEST CPEX:NAME=CPEX:0; testObject=TEST:<n> Result TEST: name = TEST:<n> testOutcome = inconclusive mOts = CPEX:0 testTermination = Cancel executedPhases phaseId = It represents the list of the executed test phases; the list is not shown for test in the waiting list (queued). .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases;the list is not shown for test in the waiting list (queued). phaseId = .... STOPTEST CPEX NACK: A30808-X3247-L230-3-7619 357 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Stoptest CPEX:NAME=CPEX:0; UNLOCK CPEX Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE CPEX UNLOCK CPEX Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state UNLOCKED. The validity range of the object address "cpexn" can be found in Appendix A. System Responses: Application Guidelines: It is possible to unlock the CPEX card with the status in LOCKED and UNDER TEST. Example of Command Execution Unlock CPEX:NAME=CPEX:0; NACK CAUSES: NO_SUCH_TEST The test is not active. UNABLE_TO_STOP_TEST The test can not be stopped. UNLOCK CPEX: NAME=CPEX:cpexn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 358 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller CTRCO The CTRCO (CTR Control) object controls the Cell Traffic Recording (CTR) tracing activities within a BSS. GET CTRCO STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO GET CTRCO STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the CTRCO object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "ctrcon" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get CTRCO STAT:NAME=CTRCO:0; GET CTRCO STAT: NAME=CTRCO:ctrcon; GET CTRCO STAT ACK: GET CTRCO STAT NACK: NACK CAUSES: None A30808-X3247-L230-3-7619 359 Commands Base Station Controller CML:BSC GETINFO CTRCO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO GETINFO CTRCO Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the whole set of information regarding the CTRCO instance active in the system. The information recovered are: 1. The states of the CTRCO: AST, OST, UST. 2. For each active CTRSCHED the following information are given: CTRSCHED instance BTSM instance BTS instance Number of active connections Max number of available connections AST,OST state and AVL status Number of CTR sched elapsed Type of record Start time Size of record. System Responses:. GETINFO CTRCO ACK: BSC_CONTROLLER -> LMT_LOCAL 11:41:14 22/03/1999 *** INFORMATION *** GETINFO REPORT CTRCO: NAME = CTRCO:0 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED USAGE STATE: IDLE LIST OF ALL CTRSCHED OBJECT: CTR# BTSM# BTS# ACTIVE CONNECTION MAX CONNECTION 0 2 118 1 5 1 6 117 0 2 ... ... ... ... ... GETINFO CTRCO: NAME=CTRCO:ctrcon; 360 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 31 12 109 2 4 CTR# ADMINISTRATIVE OPERATIONAL STATE AVAIL OFF DUTY 0 UNLOCKED ENABLED RESET 1 UNLOCKED ENABLED NONE ... ... ... ... 31 UNLOCKED ENABLED NONE CTR# ELAPSED TYPE RECORD TYPE 0 0 ALL 1 0 MESSAGE ... ... ... 31 0 ALL CTR# START TIME SIZE 0 31:Mar:2000 14:44:00 12953 1 31:Mar:2000 14:48:01 30 ... ... ... ... 31 31:Mar:2000 16:49:03 223 END OF REPORT GETINFO CTRCO NACK: BSC_CONTROLLER -> LMT_LOCAL 16:24:45 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack CTRCO: name = CTRCO:0 nackCause = <nack cause> Application Guidelines: None. NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. A30808-X3247-L230-3-7619 361 Commands Base Station Controller CML:BSC Example of Command Execution Getinfo CTRCO:NAME=CTRCO:0; LOCK CTRCO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO LOCK CTRCO Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "ctrcon" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock CTRCO:NAME=CTRCO:0; LOCK CTRCO: NAME=CTRCO:ctrcon; LOCK CTRCO ACK: LOCK CTRCO NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The selected object is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 362 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller UNLOCK CTRCO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO UNLOCK CTRCO Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "ctrcon" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock CTRCO:NAME=CTRCO:0; UPLALLCELLTR CTRCO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO UPLALLCELLTR CTRCO Applicability: Phase 2. Visibility level 2. Command Description: This command allows to upload, from BSC disk to LMT disk, the information related to the CTR tracing activities related to all cells. The validity range of the object address "ctrcon" can be found in Appendix A. UNLOCK CTRCO: NAME=CTRCO:ctrcon; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The selected object is in the administrative state UNLOCKED. UPLALLCELLTR CTRCO: NAME=CTRCO:ctrcon, DESTDIR=, OVERWRITE=; A30808-X3247-L230-3-7619 363 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: 1. If the scannerlogle is uploaded with OVERWRITE parameter set at NOand the le already exists on the LMT disk, the LMT renames the existing one to oldfilename_DayMonthYearHourMinute.Thesameextention and stores the uploaded one to the disk. 2. If the user aborts the upload command or the link (between LMT and BSC) falls down, then it is no more possible to upload the same le: a new measure le will be created until new log les will be produced inside BSC. Example of Command Execution Uplallcelltr CTRCO:NAME=CTRCO:0,DESTDIR="C:\Siemens\Trace", OVERWRITE=YES; UPLCELLTR CTRCO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO UPLCELLTR CTRCO Applicability: Phase 2. Visibility level 2. Command Description: This command allows to upload, from BSC disk to LMT disk, the information related to the CTR tracing activities related the cell defined by means of the CID parameter. The validity range of the object address "ctrcon" can be found in Appendix A. System Responses: UPLALLCELLTR ACK: UPLALLCELLTR NACK: NACK CAUSES: DIRECTORY_NOT_FOUND FILE_NOT_FOUND UPLCELLTR CTRCO: NAME=CTRCO:ctrcon, DESTDIR=, OVERWRITE=, CID=; UPLCELLTR ACK: UPLCELLTR NACK: NACK CAUSES: DIRECTORY_NOT_FOUND FILE_NOT_FOUND 364 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. If the scannerlogle is uploaded with OVERWRITE parameter set at NOand the le already exists on the LMT disk, the LMT renames the existing one to oldfilename_DayMonthYearHourMinute.Thesameextention and stores the uploaded one to the disk. 2. If the user aborts the upload command or the link (between LMT and BSC) falls down, then it is no more possible to upload the same le: a new measure le will be created until new log les will be produced inside BSC. Example of Command Execution Uplcelltr CTRCO:NAME=CTRCO:0,DESTDIR="C:\Trace", OVERWRITE=NO,CID=BTSM:0/BTS:0; A30808-X3247-L230-3-7619 365 Commands Base Station Controller CML:BSC CTRSCHED The CTRSCHED (CTR Scheduler) object provides the schedulation of the Cell Traffic Recording (CTR) tracing activities within a BSS. CREATE CTRSCHED Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO CTRSCHED CREATE CTRSCHED Applicability: Phase 2. Visibility level 2. Command Description: This command creates an instance of the CTRSCHED object class. Validity ranges of the object addresses "ctrcon" and "ctrschedn" can be found in Appendix A. System Responses: Application Guidelines: 1. The STOP attribute must be set at a value greater or equal to the value of START. CREATE CTRSCHED: NAME=CTRCO:ctrcon/CTRSCHED:ctrschedn,CID= ,MACONN= [,START=] [,STOP=] ,PERWEEK= ,TRAC- ERECTYP=; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The attribute CID must refer to an equipped cell. UNSUCCESSFUL_TOO_MANY_TRACES The maximum number of connections traceable in a BSS, considering all the scheduled periods, is exceeded. UNSUCCESSFUL_CELL_ALREADY_TRACED In the same cell there must be no periods, overlapping. INVALID_COMMAND UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. UNSUCCESSFUL_VAR_OUT_OF_RANGE 366 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 2. If a cell is congured in a CTRSCHED instance, all subsequent CREATE CTRSCHED commands, related to the same cell, shall be rejected if the scheduled periods overlapped. Example of Command Execution CreateCTRSCHED:NAME=CTRCO:0/CTRSCHED:0,CID=BTSM:0/BTS:0, MACONN=8, START=2-1-2001,STOP=2-3-2003,PERWEEK=weekly((noSched(0)- noSched(0)-noSched(0)-wePeriod((3-50-14-00))-noSched(0)-noSched(0)- noSched(0))),TRACERECTYP=All; DELETE CTRSCHED Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO CTRSCHED DELETE CTRSCHED Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a previously created instance of the CTRSCHED object class. Validity ranges of the object addresses "ctrcon" and "ctrschedn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete CTRSCHED:NAME=CTRCO:0/CTRSCHED:0; DELETE CTRSCHED: NAME=CTRCO:ctrcon/CTRSCHED:ctrschedn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a CTRSCHED, the relative object instance must be in LOCKED state.. A30808-X3247-L230-3-7619 367 Commands Base Station Controller CML:BSC GET CTRSCHED Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO CTRSCHED GET CTRSCHED Applicability: Phase 2. Visibility level 0. Command Description This command is used to retrieve the parameter values of an instance of the CTRSCHED object class. Validity ranges of the object addresses "ctrcon" and "ctrschedn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get CTRSCHED:NAME=CTRCO:0/CTRSCHED:0,REQATTL=CID&MACONN& START&STOP&PERWEEK&TRACERECTYP&LSUPDTIME; GET CTRSCHED: NAME=CTRCO:ctrcon/CTRSCHED:ctrschedn [,REQATTL=CID, MACONN, START, STOP, PERWEEK, TRACERECTYP, LSUPDTIME] ; GET ACK: CID. CellIdentity MACONN. maxConnectionNumber START: startDate STOP: stopDate PERWEEK: periodWeekly TRACERECTYP: traceRecordType LSUPDTIME: lastUpdTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 368 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET CTRSCHED BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO CTRSCHED GET CTRSCHED BASICS Applicability: Phase 2. Visibility level 0. Command Description This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses "ctrcon" and "ctrschedn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get CTRSCHED BASICS:NAME=CTRCO:0/CTRSCHED:0; GET CTRSCHED STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO CTRSCHED GET CTRSCHED STAT GET CTRSCHED BASICS: NAME=CTRCO:ctrcon/CTRSCHED:ctrschedn; GET ACK: CID: CellIdentity MACONN: maxConnectionNumber START: startDate STOP: stopDate PERWEEK: periodWeekly TRACERECTYP: traceRecordType GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET CTRSCHED STAT: NAME=CTRCO:ctrcon/CTRSCHED:ctrschedn; A30808-X3247-L230-3-7619 369 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 0. Command Description This command is used to retrieve the following State/Status attributes related to the CTRSCHED object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). Validity ranges of the object addresses "ctrcon" and "ctrshedn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get CTRSCHED STAT:NAME=CTRCO:0/CTRSCHED:0; LOCK CTRSCHED Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO CTRSCHED LOCK CTRSCHED Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". Validity ranges of the object addresses "ctrcon" and "ctrschedn" can be found in Appendix A. GET CTRSCHED STAT ACK: GET CTRSCHED STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK CTRSCHED: NAME=CTRCO:ctrcon/CTRSCHED:ctrschedn; 370 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock CTRSCHED:NAME=CTRCO:0/CTRSCHED:0; SET CTRSCHED Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO CTRSCHED SET CTRSCHED Applicability: Phase 2. Visibility level 2. Command Description: This command modifies the specific parameters of the CTRSCHED object class. Validity ranges of the object addresses "ctrcon" and "ctrschedn" can be found in Appendix A. System Responses: LOCK CTRSCHED ACK: LOCK CTRSCHED NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The selected object is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SET CTRSCHED: NAME=CTRCO:ctrcon/CTRSCHED:ctrschedn [,CID=] [,MACONN=] [,START=] [,STOP=] [,PERWEEK=] [,TRACERECTYP=]; SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 371 Commands Base Station Controller CML:BSC Application Guidelines: The STOP attribute must be set at a value greater or equal to the value of START. Example of Command Execution Set CTRSCHED:NAME=CTRCO:0/CTRSCHED:0,CID=BTSM:2/BTS:2,MACONN=8, START=2-2-1995,STOP=31-12-2099,PERWEEK=all(0),TRACERECTYP=Message; UNLOCK CTRSCHED Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO CTRSCHED UNLOCK CTRSCHED Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". Validity ranges of the object addresses "ctrcon" and "ctrschedn" can be found in Appendix A. System Responses: UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The attribute CID must refer to an equipped cell. UNSUCCESSFUL_TOO_MANY_TRACES The command is rejected if the maximumnumber of connec- tions traceable in a BSS, considering all the scheduled periods, would be exceeded UNSUCCESSFUL_CELL_ALREADY_TRACED In the same cell there must be no overlapping periods. INVALID_COMMAND UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. UNSUCCESSFUL_VAR_OUT_OF_RANGE UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNLOCK CTRSCHED: NAME=CTRCO:ctrcon/CTRSCHED:ctrschedn; UNLOCK ACK: UNLOCK NACK: 372 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Unlock CTRSCHED:NAME=CTRCO:0/CTRSCHED:3; NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. A30808-X3247-L230-3-7619 373 Commands Base Station Controller CML:BSC DISK The DISK object represents the mass memory storage of the BSS. FORMAT DISK Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE DISK FORMAT DISK Applicability: Phase 2. Visibility level 3. Command Description: This command lets the user to format one or both disk copies. The validity range of the object address "diskn" can be found in Appendix A. System Responses: Application Guidelines: 1. In case of DISKCOPY=BOTH_DISK, the command formats all disk copies having the following characteristics: the administrative state LOCKED. the superordinate state UNLOCKED and ENABLED. 2. No matter the operative state of the disk (ENABLED or DISABLED) is, it will be turned to DISABLED as soon as the command is submitted. At the command execution end, the disk successfully formatted will turn to ENABLED state. 3. In case of DISKCOPY=SELECTED (0 or 1),the disk copy administrative state must be set to LOCKED by the user (see LOCK command), otherwise the command is rejected (invalid administrative state). DISKCOPY=BOTH_DISK can be selected only if both disks are present and in service. 4. If the format operation is successful, the disk administrative state must be reset to UNLOCKED by the user (see UNLOCK command). 5. A Disk Copy Format (which takes about 15 seconds) causes a total loss of its content. 6. The other File System commands cannot be executed during a format command; they will be performed at the end of the format command. FORMAT DISK: NAME=DISK:diskn [,DISKCOPY=]; FORMAT DISK ACK: FORMAT DISK NACK: NACK CAUSES: ADMINISTRATIVE_STATE_INVALID ALREADY_IN_TARGET_STATE 374 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Format DISK:NAME=DISK:0,DISKCOPY=SELECTED; GET DISK STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE DISK GET DISK STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the DISK object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Standby Status (STNDBY) Unknown Status (UNK). The validity range of the object address "diskn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get DISK STAT:NAME=DISK:0; GETRELATIONSHIP DISK Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCEDISK GETRELATIONSHIP DISK GET DISK STAT: NAME=DISK:diskn; GET DISK STAT ACK: GET DISK STAT NACK: NACK CAUSES: GETRELATIONSHIP DISK: NAME=DISK:diskn,ATTID=; A30808-X3247-L230-3-7619 375 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected HMO (Hardware Managed Object); the relationship information consist of the all FMOs (Functional Managed Object) using the HMO service. This information is included in the RELATED_FUNCTIONAL_OBJECTS attribute (ATTID parameter) and the attribute value depends on the working state of the target HMO. The DISK object does not have associated FMO. The validity range of the object address "diskn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship DISK:NAME=DISK:0,ATTID=RELATED_FUNCTIONAL_OBJECTS; GETSUBO DISK Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE DISK GETSUBO DISK Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "diskn" can be found in Appendix A. GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected HMO the list of related FMOs is displayed (HMO to FMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_ATTRIBUTES The object does not provide any relationship attribute. GETSUBO DISK: NAME=DISK:diskn; 376 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Getsubo DISK:NAME=DISK:0; GETTEST DISK Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCEDISK GETTEST DISK Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the values of all the attributes belonging to a specified test object; the test object is created by the systemas a result of a request to start a test and it is deleted when the test terminates. The validity range of the object address "diskn" can be found in Appendix A. System Responses: GETSUBO DISK ACK: The output of the command can be composed by one or more packs with a maximum number of ten subordinated mnemonics; at the end a message is displayed notifying the end of the subordinate list. GETSUBO DISK NACK: NACK CAUSES: GETTEST DISK: NAME=DISK:diskn; GETTEST DISK ACK: GETTEST DISK:NAME=DISK:0; name = TEST:<n> mOts = DISK:0 testState = It can assume one of the following values: not_initialized, idle, initializing, suspended, testing, terminating and disabled. testOutcome = It represents the test result: it can be Inconclusive (meaning-less: that is if the phases already executed were successful) or Fail (if at least one of the executed phases failed). testMonitor phaseId = It is a list of the phases to execute and their status that can be: pass, fail, running or waiting. phaseStatus = A30808-X3247-L230-3-7619 377 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Gettest DISK:NAME=DISK:0; LOCK DISK Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE DISK LOCK DISK Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "diskn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). phaseId = phaseStatus = .... GETTEST DISK NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. LOCK DISK: NAME=DISK:diskn; LOCK DISK ACK: LOCK DISK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. 378 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Lock DISK:NAME=DISK:0; PERFTEST DISK Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE DISK PERFTEST DISK Applicability: Phase 2. Visibility level 2. Command Description: This command is used to perform a test on the selected DISK object; the test consists of the following phases: Preliminary Test (start phase), Accessibility Test (WP1), Autodiagnostic Test (WP2), Remote Accessibility (WP3), Remote Autodiagnostic (WP4), File System Check (WP5), End Test (end phase). The validity range of the object address "diskn" can be found in Appendix A. System Responses: PERFTEST DISK: NAME=DISK:diskn; PERFTEST DISK ACK: PERFTEST DISK:NAME=DISK:0; testObject=TEST:<n> The test results will be displayed at the end of the test phases. Result TEST: name = TEST:<n> testOutcome = This field represents the test result; one of the following values can be displayed: Pass all the test phases are successfully performed. Inconclusive the test is aborted by the system or the test is terminated by the operator. Fail if at least one of the executed phases fail. mOts = It is the identifier of the hardware object under test. testTermination = It specifies how the test is terminated, it can assume the following values: Normal all the test phases are performed. A30808-X3247-L230-3-7619 379 Commands Base Station Controller CML:BSC Application Guidelines: 1. The unit to be diagnosed must be set, through the LOCK command, to the LOCKED state, if the diagnostic is intrusive. 2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for test" state. When the test result is: "fail" the object goes in Disabled / Failed operational state; "pass" the object goes in Enabled operational state; "inconclusive" the object returns to the operational state previous to the test or in Enabled operational state. Example of Command Execution Perftest DISK:NAME=DISK:0; STOPTEST DISK Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE DISK STOPTEST DISK Abort the test is aborted by system. Cancel the test is terminated by operator. executedPhases phaseId = It represents the list of the executed test phases (in case of successful test result, all the test phases will be listed). additionalWords = .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases; they are displayed only for test stopped during it execution. phaseId = .... poprosedRepair Action = A list of most probable fail probable causes is shown (max four messages) PERFTEST DISK NACK: NACK CAUSES: MOTS_NOT_LOCKED The selected object is not in LOCKED administrative state. OTHER_TESTS_RUNNING Other incompatible tests are already running or no more parallel execution of tests possible. STOPTEST DISK: NAME=DISK:diskn; 380 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 2. Command Description: This command allows to terminate the test previously requested; the test can be in progress or in the waiting list (queued). In the first case the process that execute the diagnostic will be interrupted by executing the end phase; in the second case the test will be removed from the waiting list. The validity range of the object address "diskn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Stoptest DISK:NAME=DISK:0; STOPTEST DISK ACK: STOPTEST DISK:NAME=DISK:0; testObject=TEST:<n> Result TEST: name = TEST:<n> testOutcome = inconclusive mOts = DISK:0 testTermination = Cancel executedPhases phaseId = It represents the list of the executed test phases; the list is not shown for test in the waiting list (queued). .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases;the list is not shown for test in the waiting list (queued). phaseId = .... STOPTEST DISK NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNABLE_TO_STOP_TEST The test can not be stopped. A30808-X3247-L230-3-7619 381 Commands Base Station Controller CML:BSC UNLOCK DISK Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE DISK UNLOCK DISK Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "diskn" can be found in Appendix A. System Responses: Application Guidelines: It is possible to unlock the DISK card with the status in LOCKED and UNDER TEST. Example of Command Execution Unlock DISK:NAME=DISK:0; UNLOCK DISK: NAME=DISK:diskn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. 382 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DK40 The DK40 object executes File System functions and monitoring of the alarm and fuse panel of the system. GET DK40 STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE DK40 GET DK40 STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the DK40 object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Standby Status (STNDBY) Unknown Status (UNK). The validity range of the object address "dk40n" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get DK40 STAT:NAME=DK40:0; GET DK40 STAT: NAME=DK40:dk40n; GET DK40 STAT ACK: GET DK40 STAT NACK: NACK CAUSES: A30808-X3247-L230-3-7619 383 Commands Base Station Controller CML:BSC GETRELATIONSHIP DK40 Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE DK40 GETRELATIONSHIP DK40 Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected HMO (Hardware Managed Object); the relationship information consist of the all FMOs (Functional Managed Object) using the HMO service. This information is included in the RELATED_FUNCTIONAL_OBJECTS attribute (ATTID parameter) and the attribute value depends on the working state of the target HMO. The DK40 object doesnt have associated FMO. The validity range of the object address "dk40n" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship DK40:NAME=DK40:0,ATTID=RELATED_FUNCTIONAL_OBJECTS; GETSUBO DK40 Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE DK40 GETSUBO DK40 GETRELATIONSHIP DK40: NAME=DK40:dk40n,ATTID=; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected HMO the list of related FMOs is displayed (HMO to FMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_ATTRIBUTES The object does not provide any relationship attribute. GETSUBO DK40: NAME=DK40:dk40n; 384 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "dk40n" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo DK40:NAME=DK40:0; GETTEST DK40 Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCEDK40 GETTEST DK40 Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the values of all the attributes belonging to a specified test object; the test object is created by the systemas a result of a request to start a test and it is deleted when the test terminates. The validity range of the object address "dk40n" can be found in Appendix A. System Responses: GETSUBO DK40 ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end there a message is displayed noti- fying the end of the subordinate list. GETSUBO DK40 NACK: NACK CAUSES: GETTEST DK40: NAME=DK40:dk40n; GETTEST DK40 ACK: GETTEST DK40:NAME=DK40:0; name = TEST:<n> mOts = DK40:0 A30808-X3247-L230-3-7619 385 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Gettest DK40:NAME=DK40:0; LOCK DK40 Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE DK40 LOCK DK40 Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "dk40n" can be found in Appendix A. System Responses: testState = It can assume one of the following values: not_initialized, idle, initializing, suspended, testing, terminating and disabled. testOutcome = It represents the test result: it can be Inconclusive (meaning-less: that is if the phases already executed were successful) or Fail (if at least one of the executed phases failed). testMonitor phaseId = It is a list of the phases to execute and their status that can be: pass, fail, running or waiting. phaseStatus = phaseId = phaseStatus = .... GETTEST DK40 NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. LOCK DK40: NAME=DK40:dk40n; LOCK DK40 ACK: LOCK DK40 NACK: 386 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). 3. If DK40 will be locked when a cross copy procedure is in progress the cross copy stops and it does not restart when DK40 is unlocked again. The diagnostic on DK40 must be required in order to restart the cross copy procedure. Example of Command Execution Lock DK40:NAME=DK40:0; PERFTEST DK40 Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE DK40 PERFTEST DK40 Applicability: Phase 2. Visibility level 2. Command Description: This command is used to perform a test on the selected DK40 object; the test consists of the following phases: Accessibility Test (start phase), Forced Alarm Test (WP1), DUAM Test (WP2), FW RAM/DPR/SCC Tests (WP3), FW Hard Disk Test (WP4), Alarm Panel Test (WP5), End Test (end phase). The validity range of the object address "dk40n" can be found in Appendix A. System Responses: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. PERFTEST DK40: NAME=DK40:dk40n; PERFTEST DK40 ACK: PERFTEST DISK:NAME=DK40:0; testObject=TEST:<n> A30808-X3247-L230-3-7619 387 Commands Base Station Controller CML:BSC Application Guidelines: 1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked" state, if the diagnostic is intrusive. 2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for test" state. When the test result is: "fail" the object goes in Disabled / Failed operational state; "pass" the object goes in Enabled operational state; "inconclusive" the object returns to the operational state previous to the test or in Enabled operational state. The test results will be displayed at the end of the test phases. Result TEST: name = TEST:<n> testOutcome = This field represents the test result; one of the following values can be displayed: Pass all the test phases are successfully performed. Inconclusive the test is aborted by the system or the test is terminated by the operator. Fail if at least one of the executed phases fail. mOts = It is the identifier of the hardware object under test. testTermination = It specifies how the test is terminated, it can assume the following values: Normal all the test phases are performed. Abort the test is aborted by system. Cancel the test is terminated by operator. executedPhases phaseId = It represents the list of the executed test phases (in case of successful test result, all the test phases will be listed). additionalWords = .... failedPhases phaseId = It represents the list of the failed test phase; addi- tional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases; they are displayed only for test stopped during it execution. phaseId = .... poprosedRepair Action = A list of most probable fail probable causes is shown (max four messages) PERFTEST DK40 NACK: NACK CAUSES: MOTS_NOT_LOCKED The selected object is not in LOCKED administrative state. OTHER_TESTS_RUNNING Other incompatible tests are already running or no more parallel execution of tests possible. 388 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Perftest DK40:NAME=DK40:0; STOPTEST DK40 Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE DK40 STOPTEST DK40 Applicability: Phase 2. Visibility level 2. Command Description: This command allows to terminate the test previously requested; the test can be in progress or in the waiting list (queued). In the first case the process that execute the diagnostic will be interrupted by executing the end phase; in the second case the test will be removed from the waiting list. The validity range of the object address "dk40n" can be found in Appendix A. System Responses: STOPTEST DK40: NAME=DK40:dk40n; STOPTEST DK40 ACK: STOPTEST DISK:NAME=DK40:0; testObject=TEST:<n> Result TEST: name = TEST:<n> testOutcome = inconclusive mOts = DK40:0 testTermination = Cancel executedPhases phaseId = It represents the list of the executed test phases; the list is not shown for test in the waiting list (queued). .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases;the list is not shown for test in the waiting list (queued). phaseId = .... STOPTEST DK40 NACK: NACK CAUSES: NO_SUCH_TEST A30808-X3247-L230-3-7619 389 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Stoptest DK40:NAME=DK40:0; UNLOCK DK40 Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE DK40 UNLOCK DK40 Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "dk40n" can be found in Appendix A. System Responses: Application Guidelines: It is possible to unlock the DK40 card with the status in LOCKED and UNDER TEST. Example of Command Execution Unlock DK40:NAME=DK40:0; The test is not active. UNABLE_TO_STOP_TEST The test can not be stopped. UNLOCK DK40: NAME=DK40:dk40n; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. 390 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller ENVA The ENVA (Environmental Alarms) object is used to manage the enviromental alarms of the BSC. CREATE ENVA Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE ENVA CREATE ENVA Applicability: Phase 2. Visibility level 2. Command Description: This command adds a sense point for the alarm detection in the BSC. The validity range of the object address "envan" can be found in Appendix A. System Responses: Application Guidelines: In case the alarm absence is detected (with detection interval of one second) for a number of consecutive times equal to the triple of the threshold attribute, the end alarm condition is notified by means of a Failure Event Report with CLEARED severity. Example of Command Execution Create ENVA:NAME=ENVA:0,ENVANAME=TEMPERATURE,INTINF=low, THR=30,ASEV=CRITICAL,ASTRING="High_Temperature"; CREATE ENVA: NAME=ENVA:envan,ENVANAME= [,INTINF=] [,THR=] [,ASEV=] [,ASTRING=]; CREATE ACK: Successful CREATE NACK:: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_EXCEED_OBJECT_NBR ENVA instances greater than 4 are allowed only with the network card NTWSNAP_STLP. A30808-X3247-L230-3-7619 391 Commands Base Station Controller CML:BSC DELETE ENVA Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE ENVA DELETE ENVA Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a configurated sense point for the alarm detection in the BSC. The validity range of the object address "envan" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete ENVA:NAME=ENVA:0; GET ENVA Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE ENVA GET ENVA Applicability: Phase 2. Visibility level 1. DELETE ENVA: NAME=ENVA:envan; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting an ENVA, the relative object instance must be in LOCKED state. GET ENVA: NAME=ENVA:envan [,REQATTL=ENVANAME, INTINF, THR, ASEV, ASTRING]; 392 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command is used to retrieve the values of the parameters, selected by the operator, related to the ENVA object. The validity range of the object address "envan" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get ENVA:NAME=ENVA:0,REQATTL=ENVANAME&INTINF&THR&ASEV&ASTRING; GET ENVA BASICS Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE ENVA GET ENVA BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "envan" can be found in Appendix A. System Responses: GET ACK: ENVANAME: envaName INTINF: interfaceInformation THR: threshold ASEV: associatedSeverity ASTRING: associatedString GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET ENVA BASICS: NAME=ENVA:envan; GET ACK: ENVANAME: envaName INTINF: interfaceInformation THR: threshold A30808-X3247-L230-3-7619 393 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get ENVA BASICS:NAME=ENVA:0; GET ENVA STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE ENVA GET ENVA STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the ENVA object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "envan" can be found in Appendix A. System Responses: Application Guidelines: Only sets with raised bits are shown. ASEV: associatedSeverity ASTRING: associatedString GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET ENVA STAT: NAME=ENVA:envan; GET STAT ACK: GET STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 394 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Get ENVA STAT:NAME=ENVA:0; LOCK ENVA Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE ENVA LOCK ENVA Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The command will stop the ENVA alarms until next UNLOCK command. The validity range of the object address "envan" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock ENVA:NAME=ENVA:0; SET ENVA Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE ENVA SET ENVA LOCK ENVA: NAME=ENVA:envan; LOCK ENVA ACK: LOCK ENVA NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SET ENVA: NAME=ENVA:envan [,ENVANAME=] [,INTINF=] [,THR=] [,ASEV=] [,ASTRING=]; A30808-X3247-L230-3-7619 395 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 2. Command Description: This command modifies the sense point configuration for the alarm detection in the BSC. The validity range of the object address "envan" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Set ENVA:NAME=ENVA:0,ENVANAME=TEMPERATURE,INTINF=low,THR=28, ASEV=MAJOR,ASTRING="Temperature"; UNLOCK ENVA Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE ENVA UNLOCK ENVA Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "envan" can be found in Appendix A. System Responses: SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNLOCK ENVA: NAME=ENVA:envan; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE 396 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Unlock ENVA:NAME=ENVA:0; The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 397 Commands Base Station Controller CML:BSC EPWR The EPWR object represents the extended frame power distributor that provides power supply to the LICD and PPLD/PPXX boards configured in the extended module of the BSC. CREATE EPWR Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE EPWR CREATE EPWR Applicability: Phase 2. Visibility level 2. Command Description: This command adds an additional Power Supply (EPWR) to the system. This is required to support expansions to the Base Configuration. The validity range of the object address "epwrn" can be found in Appendix A. System Responses: Application Guidelines: 1. Before submitting the command, the relevant hardware has to be plugged in proper slot. 2. After the creation of the object, the ADMINISTRATIVE state of this object is set to UNLOCKED. The UNLOCK command is NOT required to put this object in service. 3. It should be avoided to create and equipped only one EPWR. Example of Command Execution Create EPWR:NAME=EPWR:0; CREATE EPWR: NAME=EPWR:epwrn; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_COMMAND_REJECTED No EPWR instance can be created if the network card is NTWSNAP_STLP. 398 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DELETE EPWR Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE EPWR DELETE EPWR Applicability: Phase 2. Visibility level 2. Command Description: This command deletes the additional Power Supply (EPWR) previously created through the CREATE EPWR command. The validity range of the object address "epwrn" can be found in Appendix A. System Responses: Application Guidelines: The relevant hardware can be unplugged after submitting the command. Example of Command Execution Delete EPWR:NAME=EPWR:0; DELETE EPWR: NAME=EPWR:epwrn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_SUBORDINATE_EQUIPPED Before deleting the last EPWR object instance all the instances of the QTLP/PPLD/PPXU objects, related to the extended module of the BSC, must be deleted. In order to delete the last EPWR no PCUs must be equipped. UNSUCCESSFUL_INVALID_STATUS The object has to be previously set at the LOCKEDstate through the LOCK command. Furthermore its state must be DISABLED and to achieve this the concerned REQ_SWITCH at EPWR rack must be set at OFF. UNSUCCESSFUL_IN_TEST A diagnostic test is running on the relevant hardware. A30808-X3247-L230-3-7619 399 Commands Base Station Controller CML:BSC GET EPWR Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE EPWR GET EPWR Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the EQUIPPED status of the additional Power Supply (EPWR) previously created through the CREATE EPWR command. The validity range of the object address "epwrn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get EPWR:NAME=EPWR:0; GET EPWR STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE EPWR GET EPWR STAT Applicability: Phase 2. Visibility level 0. GET EPWR: NAME=EPWR:epwrn; GET ACK: NAME: name GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. GET EPWR STAT: NAME=EPWR:epwrn; 400 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command is used to retrieve the following State/Status attributes related to the EPWR object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "epwrn" can be found in Appendix A. System Responses: Application Guidelines: Only sets with raised bits are shown. Example of Command Execution Get EPWR STAT:NAME=EPWR:0; GETSUBO EPWR Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE EPWR GETSUBO EPWR Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "epwrn" can be found in Appendix A. GET EPWR STAT ACK: GET EPWR STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETSUBO EPWR: NAME=EPWR:epwrn; A30808-X3247-L230-3-7619 401 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Getsubo EPWR:NAME=EPWR:0; GETTEST EPWR Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCEEPWR GETTEST EPWR Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the values of all the attributes belonging to a specified test object; the test object is created by the systemas a result of a request to start a test and it is deleted when the test terminates. The validity range of the object address "epwrn" can be found in Appendix A. System Responses: GETSUBO EPWR ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GETSUBO EPWR NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETTEST EPWR: NAME=EPWR:epwrn; GETTEST EPWR ACK: GETTEST EPWR:NAME=EPWR:0; name = TEST:<n> mOts = EPWR:0 testState = It can assume one of the following values: not_initialized, idle, initializing, suspended, testing, terminating and disabled. testOutcome = It represents the test result: it can be Inconclusive (meaning-less: that is if the phases already executed were successful) or Fail (if at least one of the executed phases failed). testMonitor 402 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Gettest EPWR:NAME=EPWR:0; LOCK EPWR Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCEEPWR LOCK EPWR Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "epwrn" can be found in Appendix A. System Responses: phaseId = It is a list of the phases to execute and their status that can be: pass, fail, running or waiting. phaseStatus = phaseId = phaseStatus = .... GETTEST EPWR NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. LOCK EPWR: NAME=EPWR:epwrn; LOCK EPWR ACK: LOCK EPWR NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 403 Commands Base Station Controller CML:BSC Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock EPWR:NAME=EPWR:0; PERFTEST EPWR Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE EPWRPERFTEST EPWR Applicability: Phase 2. Visibility level 2. Command Description: This command is used to perform a test on the selected EPWR object; the test consists of the following phases: Accessibility Test (start phase), Basic Maintenance Test (WP1), Full Maintenance Test (WP2), End Test (end phase). The validity range of the object address "epwrn" can be found in Appendix A. System Responses: PERFTEST EPWR: NAME=EPWR:epwrn; PERFTEST EPWR ACK: PERFTEST EPWR:NAME=EPWR:0; testObject=TEST:<n> The test results will be displayed at the end of the test phases. Result TEST: name = TEST:<n> testOutcome = This field represents the test result; one of the following values can be displayed: Pass all the test phases are successfully performed. Inconclusive the test is aborted by the system or the test is terminated by the operator. Fail if at least one of the executed phases fail. 404 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The test can be executed with the object in Unlocked administrative state. 2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for test" state. When the test result is: "fail" the object goes in Disabled / Failed operational state; "pass" the object goes in Enabled operational state; "inconclusive" the object returns to the operational state previous to the test or in Enabled operational state. Example of Command Execution Perftest EPWR:NAME=EPWR:0; mOts = It is the identifier of the hardware object under test. testTermination = It specifies how the test is terminated, it can assume the following values: Normal all the test phases are performed. Abort the test is aborted by system. Cancel the test is terminated by operator. executedPhases phaseId = It represents the list of the executed test phases (in case of successful test result, all the test phases will be listed). additionalWords = .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases; they are displayed only for test stopped during it execution. phaseId = .... poprosedRepair Action = A list of most probable fail probable causes is shown (max four messages) PERFTEST EPWR NACK: NACK CAUSES: OTHER_TESTS_RUNNING Other incompatible tests are already running or no more parallel execution of tests possible. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. A30808-X3247-L230-3-7619 405 Commands Base Station Controller CML:BSC STOPTEST EPWR Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE EPWRSTOPTEST EPWR Applicability: Phase 2. Visibility level 2. Command Description: This command allows to terminate the test previously requested; the test can be in progress or in the waiting list (queued). In the first case the process that execute the diagnostic will be interrupted by executing the end phase; in the second case the test will be removed from the waiting list. The validity range of the object address "epwrn" can be found in Appendix A. System Responses: STOPTEST EPWR: NAME=EPWR:epwrn; STOPTEST EPWR ACK: STOPTEST EPWR:NAME=EPWR:0; testObject=TEST:<n> Result TEST: name = TEST:<n> testOutcome = inconclusive mOts = EPWR:0 testTermination = Cancel executedPhases phaseId = It represents the list of the executed test phases; the list is not shown for test in the waiting list (queued). .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases;the list is not shown for test in the waiting list (queued). phaseId = .... STOPTEST EPWR NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. 406 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Stoptest EPWR:NAME=EPWR:0; UNLOCK EPWR Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE EPWR UNLOCK EPWR Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "epwrn" can be found in Appendix A. System Responses: Application Guidelines: It is possible to unlock the EPWR card with the status in LOCKED and UNDER TEST. Example of Command Execution Unlock EPWR:NAME=EPWR:0; UNABLE_TO_STOP_TEST The test can not be stopped. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. UNLOCK EPWR: NAME=EPWR:epwrn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 407 Commands Base Station Controller CML:BSC FAN The FAN object represents the complex of 6 fans contained in the box placed on top of the BSC. The fans are present only in the new BSC rack. GET FAN STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE FAN GET FAN STAT Applicability: Phase 2. Visibility level 0. Command Description This command is used to retrieve the following State/Status attributes related to the FAN object: Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CST) Unknown Status (UNK). The validity range of the object address "fann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get FAN STAT:NAME=FAN:0; GET FAN STAT: NAME=FAN:fann; GET FAN STAT ACK: GET FAN STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 408 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETRELATIONSHIP FAN Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE FAN GETRELATIONSHIP FAN Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected HMO (Hardware Managed Object); the relationship information consist of all the FMOs (Functional Managed Object) using the HMO service. This information is included in the RELATED_FUNCTIONAL_OBJECTS attribute (ATTID parameter) and the attribute value depends on the working state of the target HMO. The validity range of the object address fann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship FAN:NAME=FAN:0,ATTID=RELATED_FUNCTIONAL_OBJECTS; GETSUBO FAN Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE FAN GETSUBO FAN GETRELATIONSHIP FAN: NAME=FAN:fann,ATTID=; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected HMO the list of related FMOs is displayed (HMO to FMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. GETSUBO FAN: NAME=FAN:fann; A30808-X3247-L230-3-7619 409 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "fann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo FAN:NAME=FAN:0; GETSUBO FAN ACK: The output of the command can be composed by one or more pack with a maximumnumber of ten subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GETSUBO FAN NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 410 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller FHSY FHSY logs all information related to the rules of the frequency hopping systemfor each cell of the BSC. CREATE FHSY Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS FHSY CREATE FHSY Applicability: Phase 2. Visibility level 2. Command Description: This command creates an hopping law. The frequency list (MOBALLOC) is composed of the frequencies of the previously created TRX, in case of base band hopping and of the frequencies previously assigned to BTS, excluding BCCH frequency, in case of synthesizer hopping. Validity ranges of the object addresses btsmn, "btsn" and "fhsyn" can be found in Appendix A. System Responses: CREATE FHSY: NAME=BTSM:btsmn/BTS:btsn/FHSY:fhsyn ,HSN= ,MOBALLOC= [,AMRFRC1=] [,AMRFRTH12=] [,AMRFRC2=] [,AMRFRTH23=] [,AMRFRC3=] [,AMRFRTH34=] [,AMRFRC4=] [,AMRHRC1=] [,AMRHRTH12=] [,AMRHRC2=] [,AMRHRTH23=] [,AMRHRC3=] [,AMRHRTH34=] [,AMRHRC4=] [,AMRFRIC=] [,AMRHRIC=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The BTS object instance must already be equipped. UNSUCCESSFUL_TRX_FREQ_NOT_FOUND In case of base band frequency hopping, the frequencies specified in the MOBALLOC parameter do not belong to any instance of TRXs already equipped. A30808-X3247-L230-3-7619 411 Commands Base Station Controller CML:BSC UNSUCCESSFUL_OVERLAP_BAND If the cell which the FHSY belongs to is a EXT900 cell, the frequencies contained in the MOBALLOC list have to be chosen to avoid overlapping between the two bands of frequencies (primary GSM and GSM extension). If the cell which the FHSY belongs to is a GSMDCS cell, the frequencies contained in the MOBALLOC list have to be chosen to avoid overlapping between the three bands of frequencies (primary GSM, GSM extension and DCS1800 band). If the cell which the FHSY belongs to is a GSM850PCS cell, the frequencies contained in the MOBALLOC list have to be chosen to avoid overlapping between the two bands of frequencies (GSM850 and PCS1900). If the cell which the FHSY belong to is a GSM850PCS cell, the frequencies contained in the MOBALLOC list have to be chosen to avoid overlapping between the two bands of frequencies (GSM850 and PCS1900). If the cell which the FHSY belongs to is a GSM850DCS cell, the frequencies contained in the MOBALLOC list have to be chosen to avoid overlapping between the two bands of frequencies (GSM850 and DCS1800). UNSUCCESSFUL_EQUAL_FREQ In the MOBALLOC attribute cannot be set a CALLF<nn> field more than one time. UNSUCCESSFUL_FREQUENCY_NOT_BELONG_TO_CEL In case of synthesized frequency hopping, the frequencies speci- fied in the "mobile allocation" parameter must belong to the frequency assigned to the cell. FREQUENCY_NOT_ALLOWED In case of synthesizer frequency hopping, the BCCH frequency of the cell (BCCHFREQ attribute of the BTS object) cannot be included in the "mobile allocation". HSCSD_HOPP_INCONSISTENT In a cell with Base Band Hopping Mode, if the HSCSD service is activated at BTS side (i.e. attribute BTSHSCSD of BTS object set at TRUE) and one or more CCCHs have already been equipped in the cell the MOBALLOC cannot contain the BCCH frequency. GPRS_HOPP_INCONSISTENT If the TRX has the GSUP set at TRUE single TCHs must have the same FHSYD and MAIO, and if one or more CCCHs have already been equipped the channels cannot hop (i.e. FHSYD attribute must be 0). INVALID_RATE The value of the AMRFRCi (AMRHRCi) attribute must be smaller than the value of the AMRFRCi+1 (AMRHRCi+1) attribute. If the AMRFRCi (AMRHRCi) attribute is not configured, also all the subsequent AMRFRCj (AMRHRCj) attributes have not to be configured (j > i). The attribute AMRHRCi must be not set at value RATE_04 if bts hw version is BS 2x/6x. The AMRHRCi attribute can be set at value RATE_05 (7.40 kbit/s) only if the BTS HW version is BTSplus. 412 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The following relations between the Threshold and Hysteresis elds of two adjacent Codecs must be satised when the value of the AMRFRCi (AMRHRCi) attribute is changed: TH(i-1) <= TH(i) <= TH(i+1) (TH + HYS)(i-1) <= (TH + HYS)(i) <= (TH + HYS)(i+1) 2. The AMRFRTHij (AMRHRTHij) attribute can be set at NULL value only if AMRFRCj (AMRHRCj) attribute is already set at NULL. 3. It is not possible to set all AMRFRCi (AMRHRCi) attributes at NULL; at least one value must be congured. Example of Command Execution Create FHSY:NAME=BTSM:0/BTS:0/FHSY:1,HSN=2,MOBALLOC=CALLF01, AMRFRC1=RATE_01,AMRFRTH12=2-3; DELETE FHSY Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS FHSY DELETE FHSY Applicability: Phase 2. Visibility level 2. Command Description: This command deletes an hopping law. Validity ranges of the object addresses btsmn, "btsn" and "fhsyn" can be found in Appendix A. UNSUCCESSFUL_VAR_OUT_OF_RANGE One ore more variables have been incorrectly set. UNSUCCESSFUL_HOPPING_SYSTEM_INCONSISTENT All the TRXs belonging to the hopping law must have the same TRXMODE (mixed configuration EDGE/GSM is not allowed). If the cell supports EDGE the following conditions cannot be satis- fied at the same time: HoppingMode is Base Band, the BCCH frequency belongs to the hopping law you are creating (and the BCCHTRXhas TRXMD=EDGE), and the EBCCHTRXattribute of the PTPPKF object is set to FALSE. INVALID_SVR The AMRHRCi attribute can not be set at value RATE_05 (7.40 kbit/s) if the SW version running on the superordinate BTSM belongs to BR6.0 release (see EXPSWV parameter description). DELETE FHSY: NAME=BTSM:btsmn/BTS:btsn/FHSY:fhsyn; A30808-X3247-L230-3-7619 413 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Delete FHSY:NAME=BTSM:0/BTS:0/FHSY:1; GET FHSY Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMBTS FHSY GET FHSY Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the value of the parameters selected by the operator by means of REQATTL field. Validity ranges of the object addresses btsmn, "btsn" and "fhsyn" can be found in Appendix A. System Responses: DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_SUBORDINATE_EQUIPPED The FHSY instance must not be pointed by any CHAN instance, otherwise the DELETE command is rejected. GET FHSY: NAME=BTSM:btsmn/BTS:btsn/FHSY:fhsyn [,REQATTL=HSN, MOBALLOC, AMRFRC1, AMRFRTH12, AMRFRC2, AMRFRTH23, AMRFRC3, AMRFRTH34, AMRFRC4, AMRHRC1, AMRHRTH12, AMRHRC2, AMRHRTH23, AMRHRC3, AMRHRTH34, AMRHRC4, AMRFRIC, AMRHRIC]; GET ACK: NAME:name HSN:hoppingSequenceNumber MOBALLOC:mobileAllocation AMRFRC1:aMRFullRateCodec1 AMRFRTH12:aMRFullRateThresholds12 414 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get FHSY:NAME=BTSM:0/BTS:0/FHSY:1,REQATTL=HSN&MOBALLOC& AMRFRC1&AMRFRTH12&AMRFRC2&AMRFRTH23&AMRFRC3&AMRFRTH34& AMRFRC4&AMRHRC1&AMRHRTH12&AMRHRC2&AMRHRTH23&AMRHRC3& AMRHRTH34&AMRHRC4&AMRFRIC&AMRHRIC; GET FHSY BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS FHSY GET FHSY BASICS Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses btsmn, "btsn" and "fhsyn" can be found in Appendix A. AMRFRC2:aMRFullRateCodec2 AMRFRTH23:aMRFullRateThresholds23 AMRFRC3:aMRFullRateCodec3 AMRFRTH34:aMRFullRateThresholds34 AMRFRC4:aMRFullRateCodec4 AMRHRC1:aMRHalfRateCodec1 AMRHRTH12:aMRHalfRateThresholds12 AMRHRC2:aMRHalfRateCodec2 AMRHRTH23:aMRHalfRateThresholds23 AMRHRC3:aMRHalfRateCodec3 AMRHRTH34:aMRHalfRateThresholds34 AMRHRC4:aMRHalfRateCodec4 AMRFRIC:aMRFullRateInitialCodec AMRHRIC:aMRHRInitialCodec GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET FHSY BASICS: NAME=BTSM:btsmn/BTS:btsn/FHSY:fhsyn; A30808-X3247-L230-3-7619 415 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Get FHSY BASICS:NAME=BTSM:0/BTS:0/FHSY:1; SET FHSY Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMBTS FHSY SET FHSY GET ACK: NAME:name HSN:hoppingSequenceNumber MOBALLOC:mobileAllocation AMRFRC1:aMRFullRateCodec1 AMRFRTH12:aMRFullRateThresholds12 AMRFRC2:aMRFullRateCodec2 AMRFRTH23:aMRFullRateThresholds23 AMRFRC3:aMRFullRateCodec3 AMRFRTH34:aMRFullRateThresholds34 AMRFRC4:aMRFullRateCodec4 AMRHRC1:aMRHalfRateCodec1 AMRHRTH12:aMRHalfRateThresholds12 AMRHRC2:aMRHalfRateCodec2 AMRHRTH23:aMRHalfRateThresholds23 AMRHRC3:aMRHalfRateCodec3 AMRHRTH34:aMRHalfRateThresholds34 AMRHRC4:aMRHalfRateCodec4 AMRFRIC:aMRFullRateInitialCodec AMRHRIC:aMRHRInitialCodec GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SET FHSY: NAME=BTSM:btsmn/BTS:btsn/FHSY:fhsyn [,HSN=] [,MOBALLOC=] [,AMRFRC1=] [,AMRFRTH12=] [,AMRFRC2=] [,AMRFRTH23=] [,AMRFRC3=] [,AMRFRTH34=] [,AMRFRC4=] [,AMRHRC1=] [,AMRHRTH12=] [,AMRHRC2=] [,AMRHRTH23=] [,AMRHRC3=] [,AMRHRTH34=] [,AMRHRC4=] [,AMRFRIC=] [,AMRHRIC=]; 416 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 2. Command Description: This command modifies an hopping law. Validity ranges of the object addresses btsmn, "btsn" and "fhsyn" can be found in Appendix A. System Responses: SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_SUBORDINATE_EQUIPPED The FHSY instance must not be pointed by any CHAN instance, otherwise the MOBALLOC parameter can not be set. UNSUCCESSFUL_TRX_FREQ_NOT_FOUND In case of base band frequency hopping, the frequencies specified in the MOBALLOC parameter must belong to an instance of TRX already equipped. UNSUCCESSFUL_OVERLAP_BAND If the cell which the FHSY belongs to is a EXT900 cell, the frequencies contained in the MOBALLOC list have to be chosen to avoid overlapping between the two bands of frequencies (primary GSM and GSM extension). If the cell which the FHSY belongs to is a GSMDCS cell, the frequencies contained in the MOBALLOC list have to be chosen to avoid overlapping between the three bands of frequencies (primary GSM, GSM extension and DCS1800 band). If the cell which the FHSY belongs to is a GSM850PCS cell, the frequencies contained in the MOBALLOC list have to be chosen to avoid overlapping between the two bands of frequencies (GSM850 and PCS1900). If the cell which the FHSY belongs to is a GSM850DCS cell, the frequencies contained in the MOBALLOC list have to be chosen to avoid overlapping between the two bands of frequencies (GSM850 and DCS1800). UNSUCCESSFUL_EQUAL_FREQ In the MOBALLOCattribute a CALLF<nn> field can not be set more than once. UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_INVALID_STATUS In order to change the HSN attribute the BTS must be in LOCKED state and no CHAN instance must point to the FHSY instance. UNSUCCESSFUL_FREQUENCY_NOT_BELONG_TO_CEL A30808-X3247-L230-3-7619 417 Commands Base Station Controller CML:BSC In case of synthesized frequency hopping, the frequencies speci- fied in the MOBALLOC parameter must belong to the frequency assigned to the cell. FREQUENCY_NOT_ALLOWED In case of synthesizer frequency hopping, the BCCH frequency of the cell (BCCHFREQ attribute of the BTS object) cannot be included in the "mobile allocation". HSCSD_HOPP_INCONSISTENT In a cell with Base Band Hopping Mode, if the HSCSD service is activated at BTS side (i.e. attribute BTSHSCSD of BTS object set at TRUE) and one or more CCCHs have already been equipped in the cell the moballoc can not contain the BCCH frequency. GPRS_HOPP_INCONSISTENT If the TRX has the GSUP set at TRUE single TCHs must have the same FHSYD and MAIO, and if one or more CCCHs have already been equipped the channels cannot hop (i.e. FHSYDattribute must be 0). UNSUCCESSFUL_VAR_OUT_OF_RANGE One ore more variables have been incorrectly set. INVALID_RATE The value of the AMRFRCi (AMRHRCi) attribute must be smaller than the value of the AMRFRCi+1 (AMRHRCi+1) attribute. If the AMRFRCi (AMRHRCi) attribute is not configured, also all the subsequent AMRFRCj (AMRHRCj) attributes have not to be configured (j > i). The attribute AMRHRCi must not be set at value RATE_4 if BTS HW Version is BS 2x/6x. The AMRFRIC (AMRHRIC) attribute must not be equal to i value if the AMRFRCi (AMRHRCi) is set at NULL value. The AMRHRCi attribute can be set at value RATE_05 (7.40 kbit/s) only if the BTS HW version is BTSplus. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. UNSUCCESSFUL_HOPPING_SYSTEM_INCONSISTENT All the TRXs belonging to the hopping law must have the same TRXMODE (mixed configuration EDGE/GSM is not allowed). If the cell supports EDGE the following conditions cannot be satis- fied at the same time: HoppingMode is Base Band, the BCCH frequency belongs to the hopping law you are creating (and the BCCH TRX has TRXMD=EDGE), and the EBCCHTRX attribute of the PTPPKF object is set to FALSE. INVALID_SVR The AMRHRCi attribute can not be set at value RATE_05 (7.40 kbit/s) if the SW version running on the superordinate BTSM belongs to BR6.0 release (see EXPSWV parameter description). 418 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The following relations between the Threshold and Hysteresis elds of two adjacent Codecs must be satised when the value of the AMRFRCi (AMRHRCi) attribute is changed: TH(i-1) <= TH(i) <= TH(i+1) (TH + HYS)(i-1) <= (TH + HYS)(i) <= (TH + HYS)(i+1) 2. The AMRFRTHij (AMRHRTHij) attribute can be set at NULL value only if AMRFRCj (AMRHRCj) attribute is already set at NULL. 3. It is not possible to set all AMRFRCi (AMRHRCi) at NULL; at least one value must be congured. Example of Command Execution Set FHSY:NAME=BTSM:0/BTS:0/FHSY:1,HSN=3,MOBALLOC=CALLF02, AMRFRC1=RATE_01,AMRFRTH12=3-5,AMRHRC4=RATE_01, AMRFRIC=START_MODE_FR,AMRHRIC=START_MODE_HR; A30808-X3247-L230-3-7619 419 Commands Base Station Controller CML:BSC FILEHANDLER The FILEHANDELR object allows to handle files on BSC disks. COPY FILEHANDLER Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL FILEHANDLER COPY FILEHANDLER Applicability: Phase 2. Visibility level 2. Command Description: This command performs a copy of a software or database file on BSC disk. The validity range of the object address filehandlern can be found in Appendix A. System Responses: Application Guidelines: This command can be performed if a software or database file is present on BSC disk and it is used for recovery actions only. COPY FILEHANDLER NAME=FILEHANDLER:filehandlern, SRCPATHNAME=, DESTPATHNAME=; COPY ACK: NAME: name SRCPATHNAME: sourcePathName DESTPATHNAME: destinationPathName COPY NACK: NACK CAUSES: FILE_PRESENT The file is already present. NO_ADMITTED_OPERATION The file to be copied is a directory. FILE_NOT_FOUND The file to be copied is not found. FS_FAILED A generic file system is occurred. NOT_SYSTEM_RESOURCE The memory to be allocated is not enough. 420 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Copy FILEHANDLER:NAME=FILEHANDLER:0,SRCPATHNAME="Source_dir", DESTPATHNAME="Dest_dir"; CREATEDIR FILEHANDLER Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL FILEHANDLER CREATEDIR FILEHANDLER Applicability: Phase 2. Visibility level 2. Command Description: This command performs a creation of a disk directory. The validity range of the object address filehandlern can be found in Appendix A. System Responses: Application Guidelines: This command must be used for recovery actions only. Example of Command Execution Createdir FILEHANDLER:NAME=FILEHANDLER:0,DIRNAME="Dir_Name"; CREATEDIR FILEHANDLER NAME=FILEHANDLER:filehandlern, DIRNAME=; CREATEDIR ACK: NAME: name DIRNAME: directoryName CREATEDIR NACK: NACK CAUSES: FILE_PRESENT The file already exists. FS_FAILED A generic file system error has occurred. A30808-X3247-L230-3-7619 421 Commands Base Station Controller CML:BSC DELETE FILEHANDLER GENFILE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL FILEHANDLER DELETE FILEHANDLER GENFILE Applicability: Phase 2. Visibility level 2. Command Description: This command performs a deletion of a generic file. The validity range of the object address filehandlern can be found in Appendix A. System Responses: Application Guidelines: This command can be performed if a software or database file is present on BSC disk and it is used for recovery actions only. Example of Command Execution Delete FILEHANDLER GENFILE:NAME=FILEHANDLER:0, PATHNAME="Path_name"; DIR FILEHANDLER Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL FILEHANDLER DIR FILEHANDLER DELETE FILEHANDLER GENFILE NAME=FILEHANDLER:filehandlern, PATHNAME=; DELETE ACK: NAME: name PATHNAME: pathName DELETE NACK: NACK CAUSES: FILE_NOT_FOUND The file to be deleted is not found. FS_FAILED A generic file system error has occurred. DIR FILEHANDLER NAME=FILEHANDLER:filehandlern, DIRNAME=; 422 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 2. Command Description: This command displays contents of the referenced BSC disk directory. The validity range of the object address filehandlern can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Dir FILEHANDLER:NAME=FILEHANDLER:0,DIRNAME="Dir_Name"; FILECOM FILEHANDLER Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL FILEHANDLER FILECOM FILEHANDLER Applicability: Phase 2. Visibility level 2. Command Description: This command performs compression procedure of a generic file. The validity range of the object address filehandlern can be found in Appendix A. DIR ACK: NAME: name DIRNAME: directoryName LFID: listOfFileIds DISK0: disk-0 DISK1: disk-1 TOTNF: totalNumberOfFiles DIR NACK: NACK CAUSES: DIRECTORY_NOT_FOUND The directory to be displayed is not found. FS_FAILED A generic file system error has occurred. FILECOM FILEHANDLER NAME=FILEHANDLER:filehandlern ,TARGDIR= ,TARGF= ,DELOPT= ,SRCDIR= ,LFID=; A30808-X3247-L230-3-7619 423 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: This command is performed if the specific generic file is present on BSCdisk and it must be used for recovery actions only. Example of Command Execution Filecom FILEHANDLER:NAME=FILEHANDLER:0,TARGDIR="Target_dir", TARGF="File_name",DELOPT=TRUE,SRCDIR="Source_dir", LFID="F_1"&"F_2"&"F_3" FILEDECOM FILEHANDLER Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL FILEHANDLER FILEDECOM FILEHANDLER Applicability: Phase 2. Visibility level 2. Command Description: This command performs a decompression procedure of a generic file. The validity range of the object address filehandlern can be found in Appendix A. System Responses: FILECOM ACK: NAME: name FILECOM NACK: NACK CAUSES: ABORT_BY_SYSTEM_NCK FILE_NOT_FOUND T_FILE_SYSTEM_ERROR FILEDECOM FILEHANDLER NAME=FILEHANDLER:filehandlern ,TARGDIR= ,SRCDIR= ,SRCFILE=; FILEDECOM ACK: NAME: name FILEDECOM NACK: NACK CAUSES: ABORT_BY_SYSTEM_NCK FILE_NOT_FOUND 424 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: This command is performed if the specific generic file is present on BSCdisk and it must be used for recovery actions only. Example of Command Execution Filedecom FILEHANDLER:NAME=FILEHANDLER:0,TARGDIR="Target_dir", SRCDIR="Source_dir",SRCFILE="File_name"; MOVE FILEHANDLER Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL FILEHANDLER MOVE FILEHANDLER Applicability: Phase 2. Visibility level 2. Command Description: This command performs moving of a software or database file present on BSC disk. The validity range of the object address filehandlern can be found in Appendix A. System Responses: Application Guidelines: 1. This command is performed if referenced le to move is present on BSC disk. 2. The command must be used for recovery actions only. MOVE FILEHANDLER NAME=FILEHANDLER:filehandlern, SRCPATHNAME=, DESTPATHNAME=; MOVE ACK: NAME: name SRCPATHNAME: sourcePathName DESTPATHNAME: destinationPathName MOVE NACK: NACK CAUSES: FILE_PRESENT The file is already present. FILE_NOT_FOUND The file to be moved is not found. FS_FAILED A generic file system is occurred. A30808-X3247-L230-3-7619 425 Commands Base Station Controller CML:BSC Example of Command Execution Move FILEHANDLER:NAME=FILEHANDLER:0,SRCPATHNAME="Source_path", DESTPATHNAME="Dest_path"; REMOVEDIR FILEHANDLER Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL FILEHANDLER REMOVEDIR FILEHANDLER Applicability: Phase 2. Visibility level 2. Command Description: This command performs a deletion of a referenced BSC disk directory. The validity range of the object address filehandlern can be found in Appendix A. System Responses: Application Guidelines: 1. This command is performed if the specic generic directory is present on BSC disk. 2. The command must be used for recovery actions only. Example of Command Execution Removedir FILEHANDLER:NAME=FILEHANDLER:0,DIRNAME="Directory"; REMOVEDIR FILEHANDLER NAME=FILEHANDLER:filehandlern ,DIRNAME=; REMOVEDIR ACK: NAME: name PATHNAME: pathName REMOVEDIR NACK: NACK CAUSES: DIRECTORY_NOT_FOUND The directory to be deleted is not found. FS_FAILED A generic file system is occurred. DIRECTORY_NOT_EMPTY The directory to be deleted is not empty. 426 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller UPLPRLOG FILEHANDLER Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL FILEHANDLER UPLPRLOG FILEHANDLER Applicability: Phase 2. Visibility level 2. Command Description: This command allows to the user to upload the proprietary log files from the BSC disk to a selected directory of the LMT. The validity range of the object address filehandlern can be found in Appendix A. System Responses: Application Guidelines: At the end of the upload procedure the local file indicated by means of DestinationDir and DestinationFile will contain the requested logger. Any time an Upload operation is requested for a proprietary log file a new file is created on the BSC disk in the LOG directory. This file will be named either /LOG/LMT_CMD.UPL or /LOG/LMT_EVE.UPL depending on the type of the proprietary log file requested (LOGTYPE). Example of Command Execution Uplprlog FILEHANDLER:NAME=FILEHANDLER:0,DESTDIR="C:\Siemens", OVERWRITE=YES,LOGTYPE=CMDRSPLOG; UPLPRLOG FILEHANDLER NAME=FILEHANDLER:filehandlern, DESTDIR=, OVERWRITE=, LOGTYPE=; UPLPRLOG ACK: NAME: name UPLPRLOG NACK: NACK CAUSES: FILE_NOT_FOUND FS_FAILED A30808-X3247-L230-3-7619 427 Commands Base Station Controller CML:BSC FRL The FRL functional object represents the physical link connection on Gb interface. The connection can be realised via A interface (PCMA) or directly to SGSN via PCMG. In case of A interface connection the 64 kbit/s time slots are reserved on PCMS and handled in TRAU as transparent channels. CREATE FRL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL FRL CREATE FRL Applicability: Phase 2. Visibility level 2. Command Description: This command creates an instance of the FRL object class. It can be done only if the PCU/PCUTD and PCMA/PCMG are created. Creation of FRL link means to make a semi-permanent network connection between the time slot on PCMA or PCMG and the corresponding time slot on internal 2 Mbit/s. The availability of time slot on internal 2 Mbit/s must be checked using data assigned in PCU/PCUTD object and the space already allocated to other FRL links. The status at creation will be Locked-Disabled/Offline. When the BSC have been aligned with the remote peer the FRL object will be put in Enabled state. The validity range of the object address "frln" can be found in Appendix A. System Responses: CREATE FRL: NAME=FRL:frln ,PCUID= ,GLK= ,GTS= [,T391=] [,N391=] [,N392=] [,N393=] [,TCONG=] [,TCONOFF=] [,FRSTD=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. SUPERORDINATE_NOTEQUIPPED The relevant PCU/PCUTD and PCMA/PCMG object instances must be already equipped. UNSUCCESSFUL_TIME_SLOT_ALREADY_ALLOCATED The timeslot inserted in the CREATE FRL command must be not allocated by other links. 428 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Create FRL:NAME=FRL:3,PCUID=PCU:0,GLK=PCMG:0,GTS=2&12,T391=10,N391=50, N392=34,N393=10,TCONG=20,TCONOFF=25,FRSTD=ITU; DELETE FRL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL FRL DELETE FRL Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a previously created instance of the FRL object class. It can be done only if all NSVC, attached to considered FRL, are deleted and the deletion implies the removing of the semi-permanent network connection. The object to be deleted shall UNSUCCESSFUL_WRONG_ME_ID The FRL can be connected only to a PCMA or a PCMG. The operator cannot specify twice the same timeslot in the timeslot list. UNSUCCESSFUL_VAR_OUT_OF_RANGE The attribute TCONOFF can assume one of the following values: 0, 10..30. UNSUCCESSFUL_INVALID_STATUS Before deleting a FRL, the relative TRAU object instance must be in LOCKED state. UNSUCCESSFUL_INVALID_TIME_SLOT The number of timeslots assigned to the FRL must be compatible with the PCMTYPE attribute of the BSC object. UNSUCCESSFUL_NOT_ENOUGH_INT_TSL The maximumnumber of FRLs that can be assigned to a PCU is 63 if the network card is NTWSNAP or NTWSNAP_STLP, 16 otherwise. UNSUCCESSFUL_EXCEED_OBJECT_NBR FRL instances greater than 31 or more than 16 FRLs for PCU are allowed only if the network card is NTWSNAP or NTWSNAP_STLP. i The value of the timer T391 set on the BSC side must be lower than the value of the timer T392 set either on the SGSNor the network side of the Frame Relay link. DELETE FRL: NAME=FRL:frln; A30808-X3247-L230-3-7619 429 Commands Base Station Controller CML:BSC be previously locked. The validity range of the object address "frln" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete FRL:NAME=FRL:3; GET FRL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL FRL GET FRL Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the parameter values of an instance of the FRL object class. The validity range of the object address "frln" can be found in Appendix A. System Responses: DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a FRL, the relative object instance must be in LOCKED state. Before deleting a FRL, the relative TRAU object instance must be in LOCKED state (if the FRL is attested on PCMA). UNSUCCESSFUL_SUBORDINATE_EQUIPPED All the NSVC object instances associated to the FRL object instance must be previously deleted. GET FRL: NAME=FRL:frln [,REQATTL=PCUID, GLK, GTS, T391, N391, N392, N393, TCONG, TCONOFF, FRSTD]; GET ACK: NAME: name PCUID: pcuIdentifier 430 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get FRL:NAME=FRL:0,REQATTL=PCUID&GLK>S&T391&N391&N392&N393& TCONG&TCONOFF&FRSTD; GET FRL BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL FRL GET FRL BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "frln" can be found in Appendix A. System Responses: GLK: gprsLink GTS: gprsTimeslot T391: timer391 N391: n391 N392: n392 N393: n393 TCONG: timeCongestion TCONOFF: timeCongestionOff FRSTD: frameRelayStandard GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET FRL BASICS: NAME=FRL:frln; GET ACK: NAME: name PCUID: pcuIdentifier GLK: gprsLink GTS: gprsTimeslot T391: timer391 N391: n391 N392: n392 A30808-X3247-L230-3-7619 431 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get FRL BASICS:NAME=FRL:0; GET FRL STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL FRL GET FRL STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the FRL object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "frln" can be found in Appendix A. System Responses: N393: n393 TCONG: timeCongestion TCONOFF: timeCongestionOff FRSTD: frameRelayStandard GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET FRL STAT: NAME=FRL:frln; GET FRL STAT ACK: GET FRL STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 432 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get FRL STAT:NAME=FRL:0; GETINFO FRL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL FRL GETINFO FRL Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The states and statuses of the FRL: AST, OST, AVS, CST, PRS. 2. The PCU or PCUTD number. 3. The FRL relative number. 4. The FRL internal timeslots map. 5. The FRL speed used. 6. The transmission load percentage (12 samples). 7. The receiving load percentage (12 samples). 8. Six samples of the following counter type in the last 5 minutes are displayed: crc counter invalid counter invalid dlci counter. 9. The list of max 32 DLCIs from network that are not matching. The validity range of the object address "frln" can be found in Appendix A. System Responses: GETINFO FRL ACK: BSC_CONTROLLER -> LMT_LOCAL 11:41:14 22/03/1999 *** INFORMATION *** GET INFO REPORT FRL: NAME = FRL:0 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE GETINFO FRL: NAME=FRL:frln; A30808-X3247-L230-3-7619 433 Commands Base Station Controller CML:BSC PROCEDURAL STATUS: NONE PCU <or PCUTD> NBR: 2 FRL RELATIVE NUMBER: 5 INTERNAL TIMESLOT MAP: 71 72 73 124 SPEED: 256 KB/S TX LOAD SAMPLES: TX LOAD: 30% ... ... TX LOAD: 30% RX LOAD SAMPLES: RX LOAD: 30% ... ... RX LOAD: 30% CRC LAST 5 MIN (6 SAMPLES): 1 5 9 INVALID LAST 5 MIN (6 SAMPLES): 2 6 INVALID DLCI LAST 5 MIN (6 SAMPLES): 7 DLCI FROM NETWORK NOT MATCHING: DLCI NR LIST (MAX 32): 19 20 30 54 60 100 210 221 233 256 315 ... ... END OF REPORT GETINFO FRL NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1*** Get Info Report Nack FRL: name = FRL:0 nackCause = <nack cause> Application Guidelines: None. Example of Command Execution Getinfo FRL:NAME=FRL:0; NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. 434 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETRELATIONSHIP FRL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL FRL GETRELATIONSHIP FRL Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of the all HMOs (Hardware Managed Object) supporting the FMO functionality. For the FRL object the related HMOs are the following: LICD/LICDS, EPWR, PPCU, PWRD, MPCC, TDPC, MEMT, NTW, PPXU and if the FRL object is connected via A interface, BSMS and TPWR objects. The validity range of the object address "frln" can be found in Appendix A System Responses: Application Guidelines: None. Example of Command Execution Getrelationship FRL:NAME=FRL:0; GETSUBO FRL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL FRL GETSUBO FRL GETRELATIONSHIP FRL: NAME=FRL:frln; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. GETSUBO FRL: NAME=FRL:frln; A30808-X3247-L230-3-7619 435 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "nsvcn" can be found in Appendix A. System Responses Application Guidelines: None. Example of Command Execution Getsubo FRL:NAME=FRL:0; LOCK FRL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL FRL LOCK FRL Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The subordinated NSVC objects shall be put in Disabled-Dependency/offline status, while the PTPPKFs attested on the same PCU becomes disabled if no NSVC is furthermore available. The command can cause services interruption. The validity range of the object address "frln" can be found in Appendix A. GETSUBO ACK: The output of the command can be composed by one or more pack with a maximumnumber of three subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GETSUBO NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK FRL: NAME=FRL:frln; 436 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock FRL:NAME=FRL:0; SET FRL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL FRL SET FRL Applicability: Phase 2. Visibility level 2. Command Description: This command modifies the specific parameters of the FRL object class. It is used to assign different time slot to a specific FRL link. The change could be increasing/decreasing the number of time slots or changing the time slot number. For all these actions the consequent semi-permanent connection shall be changed. The command must be done in Locked state in order to inform the remote end ot the new link configuration. Also T391, N391, N392 and N393 can be changed with set command. No lock procedure is foreseen for changing this attribute. The validity range of the object address "frln" can be found in Appendix A. System Responses: LOCK FRL ACK: LOCK FRL NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_STATUS ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. SET FRL: NAME=FRL:frln [,GTS=] [,T391=] [,N391=] [,N392=] [,N393=] [,TCONG=] [,TCONOFF=] [,FRSTD=]; SET FRL ACK: Successful SET FRL NACK: NACK CAUSES: A30808-X3247-L230-3-7619 437 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Set FRL:NAME=FRL:3,GTS=2&12,T391=10,N391=50,N392=34,N393=10, TCONG=20,TCONOFF=25,FRSTD=ITU; UNLOCK FRL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL FRL UNLOCK FRL Applicability: Phase 2. Visibility level 1. Command Description: This command removes the operator block and the unit remains in the operational state as it is at the moment of the command. The dependency will be removed from the subordinate NSVC objects. The validity range of the object address "frln" can be found in Appendix A. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS When the GTS attribute is changed the FRL and the relative TRAU must be in LOCKED state. The FRSTD parameter can be set only if the FRL object is in LOCKED state. UNSUCCESSFUL_TIME_SLOT_ALREADY_ALLOCATED The timeslot inserted in the SET FRL command must not be allocated by other links. UNSUCCESSFUL_INVALID_TIME_SLOT The number of timeslots assigned to the FRL must be compatible with the PCMTYPE attribute of the BSC object. UNSUCCESSFUL_NOT_ENOUGH_INT_TSL The maximumnumber of FRLs that can be assigned to a PCU is 63 if the network card is NTWSNAP or NTWSNAP_STLP, 16 otherwise. i The value of the timer T391 set on the BSC side must be lower than the value of the timer T392 set either on the SGSNor the network side of the Frame Relay link. UNLOCK FRL: NAME=FRL:frln; 438 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Unlock FRL:NAME=FRL:0; UNLOCK ACK: Successful UNLOCK NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_STATUS A30808-X3247-L230-3-7619 439 Commands Base Station Controller CML:BSC HAND The HAND object provides services to manage the parameters used in the handover control algorithm. GET HAND Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS HAND GET HAND Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the parameters used to start the handover process in case the reception signal strength, the reception quality level or the interference level are out of limits. Validity ranges of the object addresses "btsmn", "btsn" and handn can be found in Appendix A. GET HAND: NAME=BTSM:btsmn/BTS:btsn/HAND:handn [,REQATTL=INTERCH, INTRACH, IERCHOSDCCH, IRACHOSDCCH, LOTERCH, LOTRACH, RXQUALHO, RXLEVHO, DISTHO, PBGTHO, NCELL, THORQST, HOAVELEV, HOAVQUAL, HOAVDIST, HOAVPWRB, HOLTHLVDL, HOTDLINT, HOLTHLVUL, HOTULINT, HOLTHQUDL, HOLTHQUUL, HOTMSRM, DPBGTHO, HIERC, PL, HIERF, CCDIST, HORXLVDLI, HORXLVDLO, HOCCDIST, ININHO, CCELL1, CCELL2, EXTCHO, HOTMSRME, HOMSTAM, HOMRGTA, NOBAKHO, NOFREPHO, MAXFAILHO, ELIMITCH, MAIRACHO, TINOIERCHO, ERUDGR, TINHRUGR, TINHRDGR, RAVEW, RUGRUL, RUGRDL, RDGRUL, RDGRDL, RHOLTQUL, RHOLTQDL, EFULHO, THLEVFULHO, ALEVFULHO, TRFHOE, TRFHOT, TRFKPRI, TRFHITH, TRFLTH, TRFMMA, TRFMS, ELEVHOM, AMRACMRDL, HOLTHQAMRDL, HOLTHQAMRUL, HOTHAMRCDL, HOTHAMRCUL, HOTHAMRDDL, HOTHAMRDUL, EUHO, EUBCHO, EUSCHO, EUIMPHO, SG1HOPAR, SG2HOPAR, SG3HOPAR, SG4HOPAR, SG5HOPAR, SG6HOPAR, SG7HOPAR, SG8HOPAR, SG9HOPAR, SG10HOPAR, SG11HOPAR, SG12HOPAR, SG13HOPAR, SG14HOPAR, EADVCMPDCMHO, HOTHCMPLVDL, HOTHCMPLVUL, HOTHDCMLVDL, HOTHDCMLVUL]; 440 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: GET ACK: NAME = name INTERCH = enableInterCellHo INTRACH = enableIntraCellHo LOTERCH = enableLocalInterCellHo LOTRACH = enableLocalIntraCellHo RXQUALHO = enableRxQualHO, RXLEVHO = enableRxLevHO, DISTHO = enableDistanceHO, PBGTHO = enablePowerBudgetHO, NCELL = nCell, THORQST = timerHORequest, HOAVLEV = hoAveragingLev A_Lev_ho W_Lev_ho HOAVQUAL = hoAveragingQual A_Qual_ho W_Qual_ho HOAVDIST = hoAveragingDistance, HOAVPWRB = hoAverPwrBud, HOLTHLVDL = hoLowerThresholdLevDL, HOTDLINT = hoThresholdLevDLintra, HOLTHLVUL = hoLowerThresholdLevUL, HOTULINT = hoThresholdlevULintra, HOLTHQUDL = hoLowerThresholdQualDL, HOLTHQUUL = hoLowerThresholdQualUL, HOTMSRM = hoThresholdMsRangeMax, DPBGTHO = enableDelayPowerBudgetHo, HIERC = enableHierarchicalCellHo, PL = priorityLayer, HIERF = hierarchicalCellRankFlag, CCDIST = enableConcCellDist, HORXLVDLI = hoRxlevDlinner, HORXLVDLO = hoRxlevDLouter, HOCCDIST = hoConcentricCellDistance, ININHO = enableInnerInnerHo, CCELL1 = collocatedCell1, CCELL2 = collocatedCell2, EXTCHO = enableExtendedCellHo, HOTMSRME = hoThresholdMsRangeMaxEx, HOMSTAM = hoMsTaMax, HOMRGTA = hoMarginTa(Km), NOBAKHO = enableNobackHo, NOFREPHO = enableNoFailRepHo, MAXFAILHO = maxFailHo, ELIMITCH = enableLimitationIntraCellHo, A30808-X3247-L230-3-7619 441 Commands Base Station Controller CML:BSC MAIRACHO = maxIntraCellHandover, TINOIERCHO = timerNoIntraCellHo; IERCHOSDCCH=enableInterCellHoSdcch IRACHOSDCCH=enableIntraCellHoSdcch ERUDGR = enableRateUpDowngrade TINHRUGR = timerInhibitRateUpgrade TINHRDGR = timerInhibitRateDwngrade RAVEW = rateAveragingWindow RUGRUL = rateUpgradeUL RUGRDL = rateUpgradeDL RDGRUL = rateDowngradeUL RDGRDL = rateDowngradeDL RHOLTQDL = rateHoLowerThresholdQualDL RHOLTQUL = rateHoLowerThresholdQualUL EFULHO:enableFastUpLinkHO THLEVFULHO:thresholdLevFastULHo ALEVFULHO:averagedLevFastULHO TRFHOE:trafficHandoverEnable TRFHOT:trafficHandoverTimer TRFKPRI:trafficKeepPriority TRFHITH:trafficHighThreshold TRFLTH:trafficLowThreshold TRFMMA:trafficMarginMaximum TRFMS:trafficMarginStep ELEVHOM:enableLevHOMargin AMRACMRDL:aMRAveragedCMRDL HOLTHQAMRDL:hoLowerThresQualAMRDL HOLTHQAMRUL:hoLowerThresQualAMRUL HOTHAMRCDL:hoThresAMRComprDL HOTHAMRCUL:hoThresAMRComprUL HOTHAMRDDL:hoThresAMRDecomprDL HOTHAMRDUL:hoThresAMRDecomprUL EUHO:enableHoFromGsmToUmts EUBCHO:enableBetterCellHoToUmts EUSCHO:enableSufficientUmtsCoverageHoToUmts EUIMPHO:enableImperativeHoToUmts SG1HOPAR:sg1HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL SG2HOPAR:sg2HandoverParms hoLowerThresholdLevDl 442 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL SG3HOPAR:sg3HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL SG4HOPAR:sg4HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL SG5HOPAR:sg5HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL SG6HOPAR:sg6HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL SG7HOPAR:sg7HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra A30808-X3247-L230-3-7619 443 Commands Base Station Controller CML:BSC hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL rateHoLowerThresholdQualDL rateHoLowerThresholdQualUL SG8HOPAR:sg8HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL rateHoLowerThresholdQualDL rateHoLowerThresholdQualUL SG9HOPAR:sg9HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL rateHoLowerThresholdQualDL rateHoLowerThresholdQualUL SG10HOPAR:sg10HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL rateHoLowerThresholdQualDL rateHoLowerThresholdQualUL SG11HOPAR:sg11HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter 444 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller hoLowerThresholdQualDL hoLowerThresholdQualUL hoLowerThresQualAMRDL hoLowerThresQualAMRUL hoThresAMRComprDL hoThresAMRComprUL SG12HOPAR:sg12HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL hoLowerThresQualAMRDL hoLowerThresQualAMRUL hoThresAMRComprDL hoThresAMRComprUL SG13HOPAR:sg13HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL hoLowerThresQualAMRDL hoLowerThresQualAMRUL hoThresAMRDecomprDL hoThresAMRDecomprUL SG14HOPAR:sg14HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL hoLowerThresQualAMRDL hoLowerThresQualAMRUL hoThresAMRDecomprDL hoThresAMRDecomprUL EADVCMPDCMHO: enableAdvComprDecomprHO HOTHCMPLVDL: hoThresComprLevDL A30808-X3247-L230-3-7619 445 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get HAND:NAME=BTSM:0/BTS:0/HAND:0,REQATTL=INTERCH&INTRACH& IERCHOSDCCH&IRACHOSDCCH&LOTERCH&LOTRACH&RXQUALHO& RXLEVHO&DISTHO&PBGTHO&NCELL&THORQST&HOAVELEV&HOAVQUAL& HOAVDIST&HOAVPWRB&HOLTHLVDL&HOTDLINT&HOLTHLVUL&HOTULINT& HOLTHQUDL&HOLTHQUUL&HOTMSRM&DPBGTHO&HIERC&PL&HIERF& CCDIST&HORXLVDLI&HORXLVDLO&HOCCDIST&ININHO&CCELL1&CCELL2& EXTCHO&HOTMSRME&HOMSTAM&HOMRGTA&NOBAKHO&NOFREPHO& MAXFAILHO&ELIMITCH&MAIRACHO&TINOIERCHO&ERUDGR&TINHRUGR& TINHRDGR&RAVEW&RUGRUL&RUGRDL&RDGRUL&RDGRDL&RHOLTQUL& RHOLTQDL&EFULHO&THLEVFULHO&ALEVFULHO&TRFHOE&TRFHOT& TRFKPRI&TRFHITH&TRFLTH&TRFMMA&TRFMS&ELEVHOM&AMRACMRDL& HOLTHQAMRDL&HOLTHQAMRUL&HOTHAMRCDL&HOTHAMRCUL& HOTHAMRDDL&HOTHAMRDUL&EUHO&EUBCHO&EUSCHO&EUIMPHO& SG1HOPAR&SG2HOPAR&SG3HOPAR&SG4HOPAR&SG5HOPAR&SG6HOPAR& SG7HOPAR&SG8HOPAR&SG9HOPAR&SG10HOPAR&SG11HOPAR& SG12HOPAR&SG13HOPAR&SG14HOPAR&EADVCMPDCMHO&HOTHCM- PLVDL&HOTHCMPLVUL&HOTHDMPLVDL&HOTHDMPLVUL; GET HAND BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS HAND GET HAND BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses "btsmn", "btsn" and handn can be found in Appendix A. HOTHCMPLVUL: hoThresComprLevUL HOTHDMPLVDL: hoThresDecomprLevDL HOTHDMPLVUL: hoThresDecomprLevUL GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already created. GET HAND BASICS: NAME=BTSM:btsmn/BTS:btsn/HAND:handn; 446 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: GET ACK: INTERCH = enableInterCellHo INTRACH = enableIntraCellHo LOTERCH = enableLocalInterCellHo LOTRACH = enableLocalIntraCellHo RXQUALHO = enableRxQualHO, RXLEVHO = enableRxLevHO, DISTHO = enableDistanceHO, PBGTHO = enablePowerBudgetHO, NCELL = nCell, THORQST = timerHORequest, HOAVLEV = hoAveragingLev A_Lev_ho W_Lev_ho HOAVQUAL = hoAveragingQual A_Qual_ho W_Qual_ho HOAVDIST = hoAveragingDistance, HOAVPWRB = hoAverPwrBud, HOLTHLVDL = hoLowerThresholdLevDL, HOTDLINT = hoThresholdLevDLintra, HOLTHLVUL = hoLowerThresholdLevUL, HOTULINT = hoThresholdlevULintra, HOLTHQUDL = hoLowerThresholdQualDL, HOLTHQUUL = hoLowerThresholdQualUL, HOTMSRM = hoThresholdMsRangeMax, DPBGTHO = enableDelayPowerBudgetHo, HIERC = enableHierarchicalCellHo, PL = priorityLayer, HIERF = hierarchicalCellRankFlag, CCDIST = enableConcCellDist, HORXLVDLI = hoRxlevDlinner, HORXLVDLO = hoRxlevDLouter, HOCCDIST = hoConcentricCellDistance, ININHO = enableInnerInnerHo, CCELL1 = collocatedCell1, CCELL2 = collocatedCell2, EXTCHO = enableExtendedCellHo, HOTMSRME = hoThresholdMsRangeMaxEx, HOMSTAM = hoMsTaMax, HOMRGTA = hoMarginTa(Km), NOBAKHO = enableNobackHo, NOFREPHO = enableNoFailRepHo, MAXFAILHO = maxFailHo, ELIMITCH = enableLimitationIntraCellHo, MAIRACHO = maxIntraCellHandover, A30808-X3247-L230-3-7619 447 Commands Base Station Controller CML:BSC TINOIERCHO = timerNoIntraCellHo; IERCHOSDCCH=enableInterCellHoSdcch IRACHOSDCCH=enableIntraCellHoSdcch EFULHO:enableFastUpLinkHO THLEVFULHO:thresholdLevFastULHo ALEVFULHO:averagedLevFastULHO TRFHOE:trafficHandoverEnable TRFHOT:trafficHandoverTimer TRFKPRI:trafficKeepPriority TRFHITH:trafficHighThreshold TRFLTH:trafficLowThreshold TRFMMA:trafficMarginMaximum TRFMS:trafficMarginStep ELEVHOM:enableLevHOMargin AMRACMRDL:aMRAveragedCMRDL HOLTHQAMRDL:hoLowerThresQualAMRDL HOLTHQAMRUL:hoLowerThresQualAMRUL HOTHAMRCDL:hoThresAMRComprDL HOTHAMRCUL:hoThresAMRComprUL HOTHAMRDDL:hoThresAMRDecomprDL HOTHAMRDUL:hoThresAMRDecomprUL EUHO:enableHoFromGsmToUmts EUBCHO:enableBetterCellHoToUmts EUSCHO:enableSufficientUmtsCoverageHoToUmts EUIMPHO:enableImperativeHoToUmts SG1HOPAR:sg1HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL SG2HOPAR:sg2HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL SG3HOPAR:sg3HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra 448 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL SG4HOPAR:sg4HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL SG5HOPAR:sg5HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL SG6HOPAR:sg6HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL SG7HOPAR:sg7HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL rateHoLowerThresholdQualDL rateHoLowerThresholdQualUL SG8HOPAR:sg8HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra A30808-X3247-L230-3-7619 449 Commands Base Station Controller CML:BSC hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL rateHoLowerThresholdQualDL rateHoLowerThresholdQualUL SG9HOPAR:sg9HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL rateHoLowerThresholdQualDL rateHoLowerThresholdQualUL SG10HOPAR:sg10HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL rateHoLowerThresholdQualDL rateHoLowerThresholdQualUL SG11HOPAR:sg11HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL hoLowerThresQualAMRDL hoLowerThresQualAMRUL hoThresAMRComprDL hoThresAMRComprUL SG12HOPAR:sg12HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra 450 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL hoLowerThresQualAMRDL hoLowerThresQualAMRUL hoThresAMRComprDL hoThresAMRComprUL SG13HOPAR:sg13HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL hoLowerThresQualAMRDL hoLowerThresQualAMRUL hoThresAMRDecomprDL hoThresAMRDecomprUL SG14HOPAR:sg14HandoverParms hoLowerThresholdLevDl hoLowerThresholdLevUL hoThresholdLevDLintra hoThresholdLevULintra hoRxlevDLinner hoRxlevDLouter hoLowerThresholdQualDL hoLowerThresholdQualUL hoLowerThresQualAMRDL hoLowerThresQualAMRUL hoThresAMRDecomprDL hoThresAMRDecomprUL EADVCMPDCMHO: enableAdvComprDecomprHO HOTHCMPLVDL: hoThresComprLevDL HOTHCMPLVUL: hoThresComprLevUL HOTHDMPLVDL: hoThresDecomprLevDL HOTHDMPLVUL: hoThresDecomprLevUL GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 451 Commands Base Station Controller CML:BSC Example of Command Execution Get HAND BASICS:NAME=BTSM:0/BTS:0/HAND:0; GET HAND DATA Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS HAND GET HAND DATA Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the DATA group. Validity ranges of the object addresses "btsmn", "btsn" and handn can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get HAND DATA:NAME=BTSM:0/BTS:0/HAND:0; GET HAND DATA: NAME=BTSM:btsmn/BTS:btsn/HAND:handn, GET ACK: ERUDGR = enableRateUpDowngrade TINHRUGR = timerInhibitRateUpgrade TINHRDGR = timerInhibitRateDwngrade RAVEW = rateAveragingWindow RUGRUL = rateUpgradeUL RUGRDL = rateUpgradeDL RDGRUL = rateDowngradeUL RDGRDL = rateDowngradeDL RHOLTQDL = rateHoLowerThresholdQualDL RHOLTQUL = rateHoLowerThresholdQualUL GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. 452 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SET HAND Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS HAND SET HAND Applicability: Phase 2. Visibility level 2. Command Description: This command sets the parameters used to start the Handover process in case the reception signal strength, the reception quality level or the interference level are out of bounds. Validity ranges of the object addresses "btsmn", "btsn" and handn can be found in Appendix A. SET HAND: NAME=BTSM:btsmn/BTS:btsn/HAND:handn [,INTERCH=] [,INTRACH=] [,IERCHOSDCCH=] [,IRACHOSDCCH=] [,LOTERCH=] [,LOTRACH=] [,RXQUALHO=] [,RXLEVHO=] [,DISTHO=] [,PBGTHO=] [,NCELL=] [,THORQST=] [,HOAVELEV=] [,HOAVQUAL=] [,HOAVDIST=] [,HOAVPWRB=] [,HOLTHLVDL=] [,HOTDLINT=] [,HOLTHLVUL=] [,HOTULINT=] [,HOLTHQUDL=] [,HOLTHQUUL=] [,HOTMSRM=] [,DPBGTHO=] [,HIERC=] [,PL=] [,HIERF=] [,CCDIST=] [,HORXLVDLI=] [,HORXLVDLO=] [,HOCCDIST=] [,ININHO=] [,CCELL1=] [,CCELL2=] [,EXTCHO=] [,HOTMSRME=] [,HOMSTAM=] [,HOMRGTA=] [,NOBAKHO=] [,NOFREPHO=] [,MAXFAILHO=] [,ELIMITCH=] [,MAIRACHO=] [,TINOIERCHO=] [,EFULHO=] [,THLEVFULHO=] [,ALEVFULHO=] [,TRFHOE=] [,TRFHOT=] [,TRFKPRI=] [,TRFHITH=] [,TRFLTH=] [,TRFMMA=] [,TRFMS=] [,ELEVHOM=] [,AMRACMRDL=] [,HOLTHQAMRDL=] [,HOLTHQAMRUL=] [,HOTHAMRCDL=] [,HOTHAMRCUL=] [,HOTHAMRDDL=] [,HOTHAMRDUL=] [,EUHO=] [,EUBCHO=] [,EUSCHO=] [,EUIMPHO=] [,SG1HOPAR=] [,SG2HOPAR=] [,SG3HOPAR=] [,SG4HOPAR=] [,SG5HOPAR=] [,SG6HOPAR=] [,SG7HOPAR=] [,SG8HOPAR=] [,SG9HOPAR=] [,SG10HOPAR=] [,SG11HOPAR=] [,SG12HOPAR=] [,SG13HOPAR=] [,SG14HOPAR=] [,ERUDGR=] [,TINHRUGR=] [,TINHRDGR=] [,RAVEW=] [,RUGRUL=] [,RUGRDL=] [,RDGRUL=] [,RDGRDL=] [,RHOLTQUL=] [,RHOLTQDL=] [,EADVCMPDCMHO=] [,HOTHCMPLVDL=], [,HOTHCMPLVUL=] [,HOTHDCMLVDL=] [,HOTHDCMLVUL=]; A30808-X3247-L230-3-7619 453 Commands Base Station Controller CML:BSC System Responses: SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. LAST_ADJC_RESERVED_FOR_LOTRACH When the intracell handovers are MSC controlled (attribute LOTRACH of HAND object set at FALSE) one of the 32 allowed ADJCs is reserved by BSC for LOTRACH handling, so in this case the operator can configure at most 31 ADJC cells. UNSUCCESSFUL_INVALID_STATUS In order to set LOTRACH parameter, the SCA object related to the BTS must be in LOCKED state. INCOMP_NESWLOAD_VS_MESSAGE When the SGXHOPAR attribute, X = 1..14, is different from NULL, SGXHOPAR elds override the unspecic attributes shared among service groups, as shown in Appendix C. For every SGXHOPAR, X = 1..14: The attribute must be set at NULL value if the Expected SW version belongs to BR6.0 release (see EXPSWV parameter description). The EUHO, EUBCHO, EUSCHO, EUIMPHO attributes must be set at FALSE if the Software version running on the superordinate BTSM object belongs to BR6.0 release (see EXPSWV parameter description). If the superordinate BTSMSW>BR7.0 or BTSMSW=BR7.0 and BTS load>=48, EADVCMPDCMHO attribute cannot assume NULL value. If the superordinate BTSMSW<BR7.0 or BTSMSW=BR7.0 and BTS load<48, EADVCMPDCMHO attribute must assume NULL value. If the superordinate BTSMSW>BR7.0 or BTSMSW=BR7.0 and BTS load>=48, HOTHCMPLVDL attribute cannot assume NULL value. If the superordinate BTSMSW<BR7.0 or BTSMSW=BR7.0 and BTS load<48, HOTHCMPLVDL attribute must assume NULL value. If the superordinate BTSMSW>BR7.0 or BTSMSW=BR7.0 and BTS load>=48, HOTHCMPLVUL attribute cannot assume NULL value. If the superordinate BTSMSW<BR7.0 or BTSMSW=BR7.0 and BTS load<48, HOTHCMPLVUL attribute must assume NULL value. 454 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The following relationship must be satised between the value of the THORQST timer and the value of the BSCT7 timer (see BSC object): BSCT7 (BSC) < THORQST. 2. The NCELL parameter determines the maximumnumber of neighbour cells that can be sent in the HO_COND_IND message fromthe BTS to the BSC. The MAXNCELL parameter of the BSC object determines the maximum number of cells that can be sent in the HANDOVER_REQUIRED message fromBSC to MSC. Usually the value of NCELL is greater than the value of MAXNCELL. 3. When the inter cell handover is enabled (INTERCH/IERCHOSDCCH attribute) the following attributes are relevant: if none of the above ags is enabled no inter cell handover will be requested by the BTS; otherwise the following attributes are relevant: If the superordinate BTSMSW>BR7.0 or BTSMSW=BR7.0 and BTS load>=48, HOTHDCMLVDL attribute cannot assume NULL value. If the superordinate BTSMSW<BR7.0 or BTSMSW=BR7.0 and BTS load<48, HOTHDCMLVDL attribute must assume NULL value. If the superordinate BTSMSW>BR7.0 or BTSMSW=BR7.0 and BTS load>=48, HOTHDCMLVUL attribute cannot assume NULL value. If the superordinate BTSMSW<BR7.0 or BTSMSW=BR7.0 and BTS load<48, HOTHDCMLVUL attribute must assume NULL value. UNSUCCESSFUL_INVALID_ATTRIBUTES For every SGXHOPAR, X = 7..10: If SGXHOPAR is different from NULL value, it must be: rateDowngradeDL < SGXHOPAR.rateHOLowerThresholdQualDL rateDowngradeUL < SGXHOPAR.rateHOLowerThresholdQualUL. For every SGXHOPAR, X = 1..14: If SGXHOPAR is different from NULL value, it must be: SGXHOPAR.HoRxlevDLinner < SGXHOPAR.HoRxlevDLouter. For every SGXHOPAR, X = 11..14: If SGXHOPAR is different from NULL value, it must be: SGXHOPAR.hoThresAMRComprDL <= SGXHOPAR.hoThresAMRComprUL. The EUBCHO attribute cannot be set at TRUE if the FDDREPQTY attribute (see BTS object) is set at EC_N0. The following condition must be satisfied: HOTHAMRCDL <= HOTHAMRCUL enableDistanceHO HAND:DISTHO enablePowerBudgetHO HAND:PBGTHO enableRxQualHO HAND:RXQUALHO enableRxLevHO HAND:RXLEVHO enableFastUplinkHO HAND:EFULHO A30808-X3247-L230-3-7619 455 Commands Base Station Controller CML:BSC 4. When the intra cell handover is enabled (INTRACH/IRACHOSDCCH attribute) the following attributes are relevant: 5. When the handover due to bad uplink or downlink received quality is enabled (RXQUALHO attribute) the following attributes are relevant: 6. When the handover due to uplink or downlink received low level is enabled (RXLEVHO attribute) the following attributes are relevant: 7. When the handover due to the distance between MS and BTS is enabled (DISTHO attribute) the following attributes are relevant: Furthermore if the attribute EXTCHO - enableExtendedCellHO is set to TRUE, the following attribute is relevant: 8. When the handover due to power budget is enabled (PBGTHO attribute) the following attributes are relevant: nCell HAND:NCELL timeHORequest HAND:THORQST bcchFrequency BTS o TGTBTS:BCCHFREQ bsIdentityCode BTS o TGTBTS:BSIC cellGlobalIdentity BTS o TGTBTS:CELLGLID msTxPwrMaxGsm BTS o TGTBTS:MSTXPMAXGSM msTxPwrMaxPcs BTS o TGTBTS:MSTXPMAXPCS msTxPwrMaxDcs BTS o TGTBTS:MSTXPMAXDCS rxLevMinCell BTS o TGTBTS:RXLEVMIN hoThresholdLevDLintra HAND:HOTDLINT hoThresholdLevULintra HAND:HOTULINT hoLowerThresholdQualDL HAND:HOLTHQUDL hoLowerThresholdQualUL HAND:HOLTHQUUL timerHORequest HAND:THORQST hoAveragingLev HAND:HOAVLEV hoAveragingQual HAND:HOAVQUAL hoAveragingQual HAND:HOAVQUAL hoLowerThresholdQualDL HAND:HOLTHQUDL hoLowerThresholdQualUL HAND:HOLTHQUUL hoAveragingLev HAND:HOAVLEV hoLowerThresholdLevDL HAND:HOLOWTDL hoLowerThresholdLevUL HAND:HOLOWTUL hoAveragingDistance HAND:HOAVDIST hoThresholdMsRangeMax HAND:HOTMSRM hoThresholdMsRangeMaxExt HAND:HOTMSRME 456 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 9. When the speed sensitive handover decision algorithm is enabled (DPBGTHO attribute) the following attributes are relevant: 10. The value of the attribute HORXLVDLO must be greater than the value of the attribute HORVLVDLI. 11. The value assigned to each eld of colocatedCells must indicate a BTS already equipped, cannot indicate the cell itself and the two elds of the attribute cannot indi- cate the same cell. 12. When the intracell handover decision for the concentric cell handover is based both on distance and rxlev (CCDIST = TRUE) the following attribute is relevant: 13. When the ranking of the target cells based on the priority layer is enabled (HIERC) the following attributes are relevant: 14. The CCDIST attribute can be set at TRUE only if the excessive distance is not enabled by means of the EEXCDIST attribute of the BTS object . 15. When the excessive distance is enabled (attribute EEXCDIST of BTS object), the value assigned to the attribute excessiveDistance (attribute EXCDIST of BTSobject) must be greater than the value assigned to the other Distance Handover Thresholds: hoThresholdMsRangeMax (attribute HOTMSRM of HAND object), hoThresholdMsRangeMaxExt (attribute HOTMSRME of HAND object) in case of extended cell. 16. If the attribute NOBAKHO(enableNobackHO) is set at TRUE, the following attributes are relevant: 17. If the attribute NOFREPHO (enableNoFailrepHo) is set at TRUE, the following attributes are relevant: 18. If the attribute ELIMITCH(enableLimitationIntraCellHo) is set at TRUE, the following attributes are relevant: hoAvPwrb HAND:HOAVPWRB hoMargin ADJC:HOM hoMarginDelayTime ADJC:HOMDTIME hoMarginDynamicOffset ADJC:HOMDOFF hoMarginStaticOffset ADJC:HOMSOFF microcell ADJC:MICROCELL hoConcentricCellDistance HAND:HOCCDIST priorityLayer HAND:PL hierarchicalCellRankFlag HAND:HIERF priorityLayerNCell ADJC:PLNC penalityPriorityLayerNCell ADJC:PPLNC levelOffsetNCell ADJC:LEVONC timerInhibitBackHO ADJC:TINHBAKHO maxFailHo HAND:MAXFAILHO timerInhibitFailHO ADJC:TINHFAIHO A30808-X3247-L230-3-7619 457 Commands Base Station Controller CML:BSC Furthermore if the ag LOTRACH of HAND object is set at FALSE, the present feature can be considered as virtually disabled due the fact that every Intracell Handover will be managed via MSC. 19. The attribute TINOIERCHOshould be set at a value greater than the TIMERT7 (see BSC object) and Timer THORQST (see comand SET HAND). 20. The enableExtendedCellHo attribute can not be set at TRUE if the CELLTYPE attribute of the BTS object is not set at EXTCELL. 21. The EXTCHO attribute can be set at the value TRUE if there are trafc channels set in extended mode and also trafc channel set in not extended mode. Otherwise the distance intracell handover in the extended cell is not possible. 22. If the attribute EXTCHO (enableExtendedCellHO) is set at TRUE, the following attribute are relevant: 23. The following conditions must be satised: RateUpgradeDL < rateDowngradeDL < ratehoLowerThresholdQualDL RateUpgradeUL < rateDowngradeUL < ratehoLowerThresholdQualUL. 24. When the fast uplink handover decision algorithmis enabled (EFULHOattribute) the following attributes are relevant: 25. The trafcHighThreshold and trafcLowThreshold attributes must respect the following relationship: TRFHITH-TRFLTH >= 15. 26. The TRFMMA must be set at a value greater or equal to the value of TRFMS. 27. Due to the mapping averaged RXQUAL <-> C/I (see Tab. 6.15), the following parameters should not exceed 20 dB or be less than 1 dB: HOLTHQAMRDL, HOLTHQAMRUL, HOTHAMRCDL, HOTHAMRCUL, HOTHAMRDDL, HOTHAMRDUL. Any setting above 20 dB will not be rejected by the system, but the related handover process will be affected consequently, as the related threshold will never be reached. 28. In case of Satellites Link (Abis or Asub), Link Adaptation is blocked by the BTS. The parameter AMRACMRDL is ignored as well as all Threshold and Hysteresis settings in ACS. The Codec indicated in the ACS as Initial Codec Mode is used during the whole connection. This is valid for all BTS types. 29. For every SGXHOPAR, X = 1..14: if at least one of the SGXHOPAR attribute elds is set at a valid value, also all the other attribute elds must be set at a valid value. Example of Command Execution Set HAND:NAME=HAND:0,INTERCH=TRUE,INTRACH=TRUE, LOTERCH=FALSE,LOTRACH=FALSE,RXQUALHO=FALSE,RXLEVHO=FALSE, DISTHO=FALSE,PBGTHO=TRUE,NCELL=10,THORQST=31,HOAVLEV=31-3, maxIntraCellHO HAND:MAIRACHO timerNoIntraCellHO HAND:TINOIERCHO hoMsTaMax HAND:HOMSTAM hoMarginTa(Km) HAND:HOMRGTA extendedMode CHAN:EXTMODE averagedLevFastULHo HAND:ALEVFUHO thresholdLevFuho HAND:THLEVFULHO fastUplinkHandoverCell ADJC:FULHOC 458 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller HOAVQUAL=31-3,HOAVDIST=31,HOAVPWRB=31,HOLTHLVDL=63,HOTDLINT=63, HOLTHLUUL=63,HOTULINT=63,HOLTHQUDL=7,HOLTHQUUL=7,HOTMSRM=15, DPBGTHO=FALSE,HIERC=TRUE,PL=0,HIERF=Rank0,CCDIST=FALSE, HORLVDLI=26,HORXLVDLO=32,HOCCDIST=5,ININHO=FALSE, CCELL= not_defined-bts50,NOBAKHO=FALSE,NOFREPHO=FALSE,MAXFAILHO=4, ELIMITCH=FALSE,MAIRACHO=10,TINOIERCHO=60,EXTCHO=FALSE, HOTMSRME=100,HOMSTAM=32,HOMRGTA= 4, IERCHOSDCCH=TRUE, IRACHOSDCCH=FALSE,ERUDGR=TRUE,TINHRUGR=50, TINHRDGR=30,RAVEW=15,RUGRUL=2,RUGRDL=1,RDGRUL=5,RDGRDL=3, RHOLTQUL=6,RHOLTQDL=4,EFULHO=FALSE,THLEVFULHO=0,ALEVFULHO=1-2, TRFHOE=TRUE,TRFHOT=2,TRFKPRI=TRUE,TRFHITH=50,TRFLTH=,TRFMMA=2, TRFMS=1,ELEVHOM=TRUE,AMRACMRDL=1,HOLTHQAMRDL=1, HOLTHQAMRUL=1,HOTHAMRCDL=2,HOTHAMRCUL=1,HOTHAMRDDL=4, HOTHAMRDUL=1,EUHO=TRUE,EUBCHO=TRUE,EUSCHO=TRUE, EUIMPHO=TRUE,SG1HOPAR=15-10-20-20-30-32-4-4, SG2HOPAR=15-10-20-20-28-30-3-3,SG3HOPAR=15-10-20-20-25-30-3-3, SG4HOPAR=15-10-20-20-25-30-3-3,SG5HOPAR=10-8-20-20-25-30-3-3, SG6HOPAR=10-8-20-20-25-30-3-3,SG7HOPAR=10-8-20-20-25-30-3-3-4-4, SG8HOPAR=10-5-20-20-25-30-3-3-4-4,SG9HOPAR=10-5-20-20-25-30-3-3-3-3, SG10HOPAR=20-10-20-20-25-30-3-3-3-3, SG11HOPAR=20-10-20-20-25-30-8-8-20-20, SG12HOPAR=20-10-20-20-25-30-8-8-10-10, SG13HOPAR=20-10-20-20-25-30-8-8-8-8,SG14HOPAR=20-10-20-20-25-30-8-8-8-8, EADVCMPDCMHO=TRUE,HOTHCMPLVDL=40,HOTHCMPLVUL=40, HOTHDMPLVDL=26,HOTHDMPLVUL=26; A30808-X3247-L230-3-7619 459 Commands Base Station Controller CML:BSC HANDTD The HANDTD object provides services to manage the parameters used in the TD- SCDMA handover control algorithms. GET HANDTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD HANDTD GET HANDTD Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the parameters used to start the handover process in case the reception signal strength, the reception quality level or the interference level are out of limits. Validity ranges of the object addresses "btsmtdn", "btstdn" and handtdn can be found in Appendix A. System Responses: GET HANDTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/HANDTD:hand tdn [,REQATTL=HOTMSRMTD, INTERCH, RXQUALHO,INTRACH, RXLEVHO, DISTHO, HOAVQUAL, HOAVELEVTD, HOAVDIST,HOAVP- WRBTD, HOLTHQUDLTD, HOLTHQUULTD, HOTHR- SCPULIRA, HOTHRSCPDLIRA, HOLTHRSCPDL, HOLTHRSCPUL, HAGSMTOTDSCDMA, ELIMITCH, MAIRACHOTD, MAXFAILHOTD, NOBAKHO, NOFREPHO, PBGTHO, TINOIERCHO, THORQSTTD, EINSYSTEMHO, NCELL, LOTERCH, LOTRACH]; GET ACK: NAME = name HOTMSRMTD = hoThresholdsMsRangeMaxTD INTERCH = enableInterCellHo RXQUALHO = enableRxQualHO INTRACH = enableIntraCellHo RXLEVHO = enableRxLevHO, DISTHO = enableDistanceHO, HOAVQUAL = hoAveragingQual A_Qual_ho W_Qual_ho HOAVLEVTD = hoAveragingLevTD A_Lev_ho 460 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get HANDTD:NAME=BTSMTD:0/BTSTD:0/HANDTD:0,REQATTL=HOTM- SRMTD&INTERCH&RXQUALHO&INTRACH&RXLEVHO&DISTHO&HOAVQUAL&H OAVELEVTD&HOAVDIST&HOAVPWRBTD&HOLTHQUDLTD&HOLTHQ- UULTD&HOTHRSCPULIRA&HOTHRSCPDLIRA&HOLTHRSCPDL&HOLTHR- SCPUL&HAGSMTOTDSCDMA&ELIMITCH&MAIRACHOTD&MAXFAILHOTD&NOBA KHO&NOFREPHO&PBGTHO&TINOIERCHO&THORQSTTD&EINSYS- TEMHO&NCELL&LOTERCH&LOTRACH; W_Lev_ho HOAVDIST = hoAveragingDistance, HOAVPWRBTD = hoAverPwrBudTD HOLTHQUDLTD = hoLowerThresholdQualDLTD HOLTHQUULTD = hoLowerThresholdQualULTD HOTHRSCPULIRA= hoThresholdRSCPULintra HOTHRSCPDLIRA= hoThresholdRSCPDLintra HOLTHRSCPDL= hoLowerThresholdRSCPDL HOLTHRSCPUL= hoLowerThresholdRSCPUL HAGSMTOTDSCDMA= hoAdptGsmToTdscdma ELIMITCH = enableLimitationIntraCellHo, MAIRACHOTD = maxIntraCellHandovTD, MAXFAILHOTD = maxFailHoTD NOBAKHO = enableNobackHo, NOFREPHO = enableNoFailRepHo, PBGTHO = enablePowerBudgetHO, TINOIERCHO = timerNoIntraCellHo; THORQSTTD = timerHORequestTD EINSYSTEMHO = enableInterSystemHO NCELL = nCell, LOTERCH = enableLocalInterCellHo LOTRACH = enableLocalIntraCellHo GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already created. A30808-X3247-L230-3-7619 461 Commands Base Station Controller CML:BSC GET HANDTD BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD HANDTD GET HANDTD BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses "btsmtdn", "btstdn" and handtdn can be found in Appendix A. System Responses: GET HANDTD BASICS: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/HANDTD:hand tdn; GET ACK: NAME = name HOTMSRMTD = hoThresholdsMsRangeMaxTD INTERCH = enableInterCellHo RXQUALHO = enableRxQualHO INTRACH = enableIntraCellHo RXLEVHO = enableRxLevHO, DISTHO = enableDistanceHO, HOAVQUAL = hoAveragingQual A_Qual_ho W_Qual_ho HOAVLEVTD = hoAveragingLevTD A_Lev_ho W_Lev_ho HOAVDIST = hoAveragingDistance, HOAVPWRBTD = hoAverPwrBudTD HOLTHQUDLTD = hoLowerThresholdQualDLTD HOLTHQUULTD = hoLowerThresholdQualULTD HOTHRSCPULIRA= hoThresholdRSCPULintra HOTHRSCPDLIRA= hoThresholdRSCPDLintra HOLTHRSCPDL= hoLowerThresholdRSCPDL HOLTHRSCPUL= hoLowerThresholdRSCPUL HAGSMTOTDSCDMA= hoAdptGsmToTdscdma ELIMITCH = enableLimitationIntraCellHo, MAIRACHOTD = maxIntraCellHandovTD, MAXFAILHOTD = maxFailHoTD NOBAKHO = enableNobackHo, 462 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None Example of Command Execution Get HANDTD BASICS:NAME=BTSMTD:0/BTSTD:0/HANDTD:0; SET HANDTD Command Tree: MANAGED-ELEMENTBSS-FUNCTIONAL BTSMTD BTSTD HANDTD SET HANDTD Applicability: Phase 2. Visibility level 2. Command Description: This command sets the parameters used to start the Handover process in case the reception signal strength, the reception quality level or the interference level are out of bounds. NOFREPHO = enableNoFailRepHo, PBGTHO = enablePowerBudgetHO, TINOIERCHO = timerNoIntraCellHo; THORQSTTD = timerHORequestTD EINSYSTEMHO = enableInterSystemHO NCELL = nCell, LOTERCH = enableLocalInterCellHo LOTRACH = enableLocalIntraCellHo GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already created. SET HANDTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/HANDTD:hand tdn [,HOTMSRMTD=] [,INTERCH=] [,RXQUALHO=] [,INTRACH=] [,RXLEVHO=] [,DISTHO=] [,HOAVQUAL=] [,HOAVELEVTD=] [,HOAVDIST=] [,HOAVPWRBTD=] [,HOLTHQUDLTD=] [,HOLTHQUULTD=] [,HOTHRSCPULIRA=] [,HOTHRSCPDLIRA=] [,HOLTHRSCPDL=] [,HOLTHRSCPUL=] [,HAGSMTOTDSCDMA=] [,ELIMITCH=] [,MAIRACHOTD=] [,MAXFAILHOTD=] [,NOBAKHO=] [,NOFREPHO=] [,PBGTHO=] [,TINOIERCHO=] [,THORQSTTD=] [,EINSYSTEMHO=] [,NCELL=] [,LOTERCH=] [,LOTRACH=]; A30808-X3247-L230-3-7619 463 Commands Base Station Controller CML:BSC Validity ranges of the object addresses "btsmtdn", "btstdn" and handtdn can be found in Appendix A. System Responses: Application Guidelines: 1. The following relationship must be satised between the value of the THORQSTTD timer and the value of the BSCT7 timer (see BSC object): BSCT7 (BSC) < THORQSTTD. 2. The NCELL parameter determines the maximumnumber of neighbour cells that can be sent in the HO_COND_IND message fromthe BTS to the BSC. The MAXNCELL parameter of the BSC object determines the maximum number of cells that can be sent in the HANDOVER_REQUIRED message fromBSC to MSC. Usually the value of NCELL is greater than the value of MAXNCELL. 3. When the inter cell handover is enabled (INTERCH attribute) the following attributes are relevant: if none of the above ags is enabled no inter cell handover will be requested by the BTSTD; otherwise the following attributes are relevant: 4. When the intra cell handover is enabled (INTRACH) the following attributes are rele- vant: SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The following relationship must be fullfilled: HOTMSRMTD < EXCDISTTD (BTSTD object). The following relationship must be fullfilled: HOTHRSCPDLIRA >=HOLTHRSCPDL. The following relationship must be fullfilled: HOTHRSCPULIRA >=HOLTHRSCPUL. enableDistanceHO HANDTD:DISTHO enablePowerBudgetHO HANDTD:PBGTHO enableRxQualHO HANDTD:RXQUALHO enableRxLevHO HANDTD:RXLEVHO nCell HANDTD:NCELL timeHORequestTD HANDTD:THORQSTTD hoThresholdRSCPDLintra HANDTD:HOTHRSCPDLIRA hoThresholdRSCPULintra HANDTD:HOTHRSCPULIRA hoLowerThresholdQualDLTD HANDTD:HOLTHQUDLTD hoLowerThresholdQualULTD HANDTD:HOLTHQUULTD 464 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 5. When the handover due to bad uplink or downlink received quality is enabled (RXQUALHO attribute) the following attributes are relevant: 6. When the handover due to uplink or downlink received low level is enabled (RXLEVHO attribute) the following attributes are relevant: 7. When the handover due to the distance between MS and BTSTD is enabled (DISTHO attribute) the following attributes are relevant: 8. When the handover due to power budget is enabled (PBGTHO attribute) the following attributes are relevant: 9. If the attribute NOBAKHO(enableNobackHO) is set at TRUE, the following attributes are relevant: 10. If the attribute NOFREPHO (enableNoFailrepHo) is set at TRUE, the following attributes are relevant: 11. If the attribute ELIMITCH(enableLimitationIntraCellHo) is set at TRUE, the following attributes are relevant: Furthermore if the ag LOTRACH of HANDTD object is set at FALSE, the present feature can be considered as virtually disabled due the fact that every Intracell Handover will be managed via MSC. 12. The attribute TINOIERCHOshould be set at a value greater than the TIMERT7 (see BSC object) and Timer THORQSTTD (see comand SET HANDTD). timerHORequestTD HANDTD:THORQSTTD hoAveragingLevTD HANDTD:HOAVLEVTD hoAveragingQual HANDTD:HOAVQUAL hoAveragingQual HANDTD:HOAVQUAL hoLowerThresholdQualDLTD HANDTD:HOLTHQUDLTD hoLowerThresholdQualULTD HANDTD:HOLTHQUULTD hoAveragingLevTD HANDTD:HOAVLEVTD hoLowerThresholdRSCPDL HANDTD:HOLTHRSCPDL hoLowerThresholdRSCPUL HANDTD:HOLTHRSCPUL hoAveragingDistance HANDTD:HOAVDIST hoThresholdMsRangeMaxTD HANDTD:HOTMSRMTD hoAvPwrbTD HANDTD:HOAVPWRBTD hoMargin ADJCTD:HOM timerInhibitBackHO ADJCTD:TINHBAKHO maxFailHoTD HANDTD:MAXFAILHOTD timerInhibitFailHO ADJCTD:TINHFAIHO maxIntraCellHOTD HANDTD:MAIRACHOTD timerNoIntraCellHO HANDTD:TINOIERCHO A30808-X3247-L230-3-7619 465 Commands Base Station Controller CML:BSC Example of Command Execution Set HAND:NAME=HAND:0,HOTMSRMTD=15,INTERCH=TRUE, RXQUALHO=TRUE,INTRACH=TRUE,RXLEVHO=FALSE,DISTHO=FALSE, HOAVQUAL=31-3,HOAVLEVTD=31-3,HOAVDIST=31,HOAVPWRBTD=31, HOLTHQUDLTD=7,HOLTHQUULTD=7,HOTHRSCPULIRA=(-90),HOTHRSCPD- LIRA=(-90), HOLTHRSCPDL=(-100),HOLTHRSCPUL=(-100),HAGSMTOTD- SCDMA=(-128),ELIMITCH=FALSE,MAIRACHOTD=10,MAXFAILHOTD=4, NOBAKHO=FALSE,NOFREPHO=FALSE,PBGTHO=TRUE, TINOIERCHO=60,THORQSTTD=31,EINSYSTEMHO=FALSE,NCELL=10, LOTERCH=FALSE,LOTRACH=FALSE; 466 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller IPLI The IPLI functional object represents the IP link used for the communication between the BSC and external network elements (Radio Commander and Cell Broadcast Center). CREATE IPLI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL IPLI CREATE IPLI Applicability: Phase 2. Visibility level 2. Command Description: This command creates an instance of the IPLI object class. The IPLI object instance must be created with the following features: only one instance of the IPLI object can be created; no mixed congurations are allowed: it is possible to create either a X25A/D link or the IPLI one. After having created the IPLI object instance the user can configure the links to RC/CBC applications, creating OMAL and CBCL object instances. The validity range of the object address "iplin" can be found in Appendix A. System Responses: CREATE IPLI: NAME=IPLI:iplin ,PRIMARYIPADDR= , SECONDARYIPADDR= [,GATEWAY0=] [,GATEWAY1=], SUBNETMASK=; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESFUL_ OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. INVALID_COMMAND No mixed configurations are possible, that is, if a X25A or a X25D object is already equipped, the CREATE IPLI command is refused. UNSUCCESSFUL_INVALID_ATTRIBUTES The PRIMARYIPADDR has to be always different by SECONDARY- IPADDR. A30808-X3247-L230-3-7619 467 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Create IPLI:NAME=IPLI:0,PRIMARYIPADDR=172.31.21.88, SECONDARYIPADDR=172.31.21.90, GATEWAY0=<NULL>, GATEWAY1=<NULL>, SUBNETMASK=255.255.255.0; DELETE IPLI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL IPLI DELETE IPLI Applicability: Phase 2. Visibility level 2. Command Description: This command deletes the previously created instance of the IPLI object class. The IPLI object cannot be deleted if either the OMAL object or the CBCL object are still equipped. The validity range of the object address "iplin" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete IPLI:NAME=IPLI:0; DELETE IPLI: NAME=IPLI:iplin; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_SUBORDINATE_EQUIPPED The IPLI object cannot be deleted if either the OMAL object or the CBCL object or both are equipped. 468 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET IPLI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL IPLI GET IPLI Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the parameter values of the instance of the IPLI object class. The validity range of the object address "iplin" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get IPLI:NAME=IPLI:0,REQATTL=PRIMARYIPADDR& SECONDARYIPADDR&GATEWAY0&GATEWAY1&SUBNETMASK; GET IPLI BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL IPLI GET IPLI BASICS GET IPLI: NAME=IPLI:iplin [,REQATTL=PRIMARYIPADDR, SECONDARYIPADDR,GATEWAY0, GATEWAY1, SUBNETMASK]; GET ACK: NAME: name PRIMARYIPADDR: PrimaryIpAddress SECONDARYIPADDR: SecondaryIpAddress GATEWAY0: gateway0 GATEWAY1: gateway1 SUBNETMASK: SubnetMask GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET IPLI BASICS: NAME=IPLI:frln; A30808-X3247-L230-3-7619 469 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "iplin" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get IPLI BASICS:NAME=IPLI:0; GET IPLI STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL IPLI GET IPLI STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the IPLI object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) GET ACK: NAME: name PRIMARYIPADDR: PrimaryIpAddress SECONDARYIPADDR: SecondaryIpAddress GATEWAY0: Gateway0 GATEWAY1: Gateway1 SUBNETMASK: SubnetMask GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET IPLI STAT: NAME=IPLI:iplin; 470 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Control Status (CTS) Unknown Status (UNK). The validity range of the object address "iplin" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get IPLI STAT:NAME=IPLI:0; GETINFO IPLI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL IPLI GETINFO IPLI Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. IP Connection: its the MPCC copy that supports the active IP connection. 2. IP Operational State. 3. IP Availability Status. 4. IP Primary Address: its the IP address assigned to the Providing Service MPCC card (the RC uses this address to transmit with the BSC). 5. IP Second Address: its the IP address assigned to the Standby MPCC card (never used by RC except for the RC-BSC IP link test). 6. IP NetMask Address: its the local LAN address. 7. IP Gateway 0 Address: its the IP address of the default gateway connected to the MPCC copy 0 ( used when RC/CBC doesnt belong to tha same IP sub-network of the BSC). 8. IP Gateway 1 Address: its the IP address of the default gateway connected to the MPCC copy 1 ( used when RC/CBC doesnt belong to tha same IP sub-network of the BSC). 9. OMAL Number: its the copy of OMAL. GET IPLI STAT ACK: GET IPLI STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETINFO IPLI: NAME=IPLI:iplin; A30808-X3247-L230-3-7619 471 Commands Base Station Controller CML:BSC 10. OMAL Operational State. 11. OMAL Availability Status. 12. OMAL Standby Status. 13. Service Type: possible values are FTAM or CMIP. 14. Ftam Connection number. 15. CBCL Number: its the copy of OMAL. 16. CBCL Administrative State. 17. CBCL Operational State. 18. CBCL Availability Status. 19. CBCL Standby Status. The validity range of the object address "iplin" can be found in Appendix A. System Responses: GETINFO IPLI ACK: BSC_CONTROLLER -> LMT_LOCAL 11:41:14 22/03/1999 *** INFORMATION *** GET INFO REPORT IPLI: NAME = IPLI:0 IP CONNECTION: MPCC_0 OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE IP PRIMARY ADDRESS: 123:123:123:123 IP SECONDARY ADDRESS: 124:124:124:4 NETMASK ADDRESS: 255:0:0:0 GATEWAY 0 ADDRESS: 34:56:78:123 GATEWAY 1 ADDRESS: 37:456:123:9 OMAL 0: OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE STANDBY STATUS: NONE SERVICE TYPE: FTAM FTAM CONNECTION: 1 CBCL 1: ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE STANDBY STATUS: NONE END OF REPORT NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED 472 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Getinfo IPLI:NAME=IPLI:0; GETRELATIONSHIP IPLI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL IPLI GETRELATIONSHIP IPLI Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of the all HMOs (Hardware Managed Object) supporting the FMO functionality. The validity range of the object address "iplin" can be found in Appendix A System Responses: Application Guidelines: None. Example of Command Execution Getrelationship IPLI:NAME=IPLI:0; The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. GETRELATIONSHIP IPLI: NAME=IPLI:iplin; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 473 Commands Base Station Controller CML:BSC PING IPLI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL IPLI PING IPLI Applicability: Phase 2. Visibility level 0. Command Description: The PING IPLI command is used in order to allow the operator to test in an easy way the configuration of the BSC IP host. This command is especially useful during the IPLI configuration phase when the oper- ator is in charge of configuring the IPLI attributes according to the LAN topology, the BSC belongs to. This command allows the operator to ping, from the BSC (from either MPCC:0 or MPCC:1), a generic IP address, in order to check the correctness of all the IPLI attribute values. It must be noted, however, that the result of this test is only useful for the operator, but it will never draw to IPLI state and status change. The validity range of the object address "iplin" can be found in Appendix A. System Responses Application Guidelines: None. PING IPLI: NAME=IPLI:iplin, ; PING IPLI ACK: PING IPLI NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The MPCC card not providing service must be unlocked/hot standby UNSUCCESSFUL_COMMAND_REJECTED There is a test already in progress on same MPCCCOPY (not explicity requested from operator). UNSUCCESSFUL_COMMAND_ALREADY_IN_PROGRESS The operator has already requested a ping test on same MPCCCOPY and previous command has not finished. UNSUCCESSFUL_INVALID_ATTRIBUTES The IP address is not syntactly correct; the convention used for his value is the well-known dotted decimal format (e.g.172.31.21.88). The IP address must not be a broadcast address (e.g. xxx.xxx.xxx.255). 474 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Ping IPLI:NAME=IPLI:0; SET IPLI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL IPLI SET IPLI Applicability: Phase 2. Visibility level 2. Command Description: This command modifies the specific parameters of the IPLI object class. No lock proce- dure is foreseen for changing IPLI attributes. The validity range of the object address "iplin" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Set IPLI:NAME=IPLI:0,PRIMARYIPADDR=172.31.21.88, SECONDARYIPADDR=172.31.21.90, GATEWAY0=<NULL>, GATEWAY1=<NULL>, SUBNETMASK=255.255.255.0; SET IPLI: NAME=IPLI:iplin PRIMARYIPADDR= , SECONDARYIPADDR= [,GATEWAY0=] [,GATEWAY1=], SUBNETMASK=; SET IPLI ACK: Successful SET IPLI NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The PRIMARYIPADDR has to be always different by SECONDARYIPADDR. A30808-X3247-L230-3-7619 475 Commands Base Station Controller CML:BSC IXLT The IXLT object represents the Q3 interface module with the RCand X.25 local terminal. GET IXLT STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE IXLT GET IXLT STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the IXLT object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Standby Status (STNDBY) Unknown Status (UNK). The validity range of the object address "ixltn" can be found in Appendix A. System Responses: Application Guidelines: 1. Only sets with raised bits are shown. 2. Explanation of the meaning of IXLT status: The handling of the status attributes may be summarized as follows: GET IXLT STAT: NAME=IXLT:ixltn; GET IXLT STAT ACK: GET IXLT STAT NACK: NACK CAUSES: None. Value IXLT standby PROVIDING SERVICE IXLT UNLOCKEDand ENABLEDconfigured to support OMC and CBC link HOT STANDBY not used COLD STANDBY IXLT UNLOCKED and ENABLED and not configured NULL_STATUS IXLT LOCKED or DISABLED 476 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Get IXLT STAT:NAME=IXLT:0; GETINFO IXLT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE IXLT GETINFO IXLT Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The RSU running object and the RSU version. 2. The states and statuses of the IXLT: AST, OST, AVS, CST, STNDBYST, PRS. 3. The software working mode (SWST), which can assume the following values: UNDEFINED (when the card is disabled), FIRMWARE, SOFTWARE and LOADED. 4. The LMT link connected/not connected information. 5. The X25 is supported/not supported information. The validity range of the object address ixltn can be found in Appendix A. System Responses: GETINFO IXLT ACK: BSC_CONTROLLER -> LMT_LOCAL 11:41:14 22/03/1999 *** INFORMATION *** GET INFO REPORT: NAME = IXLT:0 RSU RUNNING: RSUEXE 4-5 RSU VERSION: 02-06-01-01-00-00_00-01-10 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED availability FAILED IXLT faulted DEGRADED if set, the IXLT is working in FW, else in SW OFF_DUTY if set LMT is not active, else it is DEPENDENCY PWRD is DISABLED or LOCKED procedural INITIALIZING IXLT is being loaded GETINFO IXLT: NAME=IXLT:ixltn; A30808-X3247-L230-3-7619 477 Commands Base Station Controller CML:BSC AVAILABILITY STATUS: NONE CONTROL STATUS: NONE STANDBY STATUS: PROVIDING_SERVICE PROCEDURAL STATUS: NONE SOFTWARE WORKING MODE: SOFTWARE LMT LINK CONNECTED: YES X25 LINK CONNECTED: TRUE END OF REPORT Note: 1. In the manual the CONSISTENCY MAP eld must be reserved for the developer. 2. The SERVICE TYPE eld is abitString map where:0 = Undened; bit 0 set = CMIP; bit 1 set = FTAM. GETINFO IXLT NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack IXLT: name = IXLT:0 nackCause = <nack cause> Application Guidelines: In the manual the CONSISTENCY MAP field must be reserved for the developer. Example of Command Execution Getinfo IXLT:NAME=IXLT:0; NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. 478 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETRELATIONSHIP IXLT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCEIXLTGETRELATIONSHIP IXLT Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected HMO (Hardware Managed Object); the relationship information consist of the all FMOs (Functional Managed Object) using the HMO service. This information is included in the RELATED_FUNCTIONAL_OBJECTS attribute (ATTID parameter) and the attribute value depends on the working state of the target HMO. For the IXLT object the OMAL and CBCL are the related FMOs. The validity range of the object address "ixltn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship IXLT:NAME=IXLT:0, ATTID=RELATED_FUNCTIONAL_OBJECTS; GETTEST IXLT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE IXLT GETTEST IXLT GETRELATIONSHIP IXLT: NAME=IXLT:ixltn,ATTID=; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected HMO the list of related FMOs is displayed (HMO to FMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. GETTEST IXLT: NAME=IXLT:ixltn; A30808-X3247-L230-3-7619 479 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the values of all the attributes belonging to a specified test object; the test object is created by the systemas a result of a request to start a test and it is deleted when the test terminates. The validity range of the object address "ixltn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Gettest IXLT:NAME=IXLT:0; LOCK IXLT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE IXLT LOCK IXLT GETTEST IXLT ACK: GETTEST IXLT:NAME=IXLT:0; name = TEST:<n> mOts = IXLT:0 testState = It can assume one of the following values: not_initialized, idle, initializing, suspended, testing, terminating and disabled. testOutcome = It represents the test result: it can be Inconclusive (meaning-less: that is if the phases already executed were successful) or Fail (if at least one of the executed phases failed). testMonitor phaseId = It is a list of the phases to execute and their status that can be: pass, fail, running or waiting. phaseStatus = phaseId = phaseStatus = .... GETTEST IXLT NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. LOCK IXLT: NAME=IXLT:ixltn; 480 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The command can be rejected due to high criticity of the system state. The validity range of the object address "ixltn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). 3. It is emitted when the PLLH has become synchronized to an external source little time ago, and the switch of the master PLLH (for LOCK or SWITCH command) would leave the frequency of the new active PLLH with a bad value; it can be answered up to 5 minutes after a SYNC or SYNE has gone PROVIDING SERVICE. The same can happen if less than 5 minutes have passed since last switch of NTW. Example of Command Execution Lock IXLT:NAME=IXLT:0; PERFTEST IXLT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE IXLT PERFTEST IXLT Applicability: Phase 2. LOCK IXLT ACK: LOCK IXLT NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. CRITICAL_ALARM_REJECTED The command can be rejected due to high criticity of the system state. PERFTEST IXLT: NAME=IXLT:ixltn; A30808-X3247-L230-3-7619 481 Commands Base Station Controller CML:BSC Visibility level 2. Command Description: This command is used to perform a test on the selected DISK object; the test consists of the following phases: Accessibility Test (start phase), Address Bus Test (WP1), Alarm Register Test (WP2), DUAM Test (WP3), FW Internal Test (WP4), End Test (end phase). The validity range of the object address "ixltn" can be found in Appendix A. System Responses: PERFTEST IXLT ACK: PERFTEST IXLT:NAME=IXLT:0; testObject=TEST:<n> The test results will be displayed at the end of the test phases. Result TEST: name = TEST:<n> testOutcome = This field represents the test result; one of the following values can be displayed: Pass all the test phases are successfully performed. Inconclusive the test is aborted by the system or the test is terminated by the operator. Fail if at least one of the executed phases fail. mOts = It is the identifier of the hardware object under test. testTermination = It specifies how the test is terminated, it can assume the following values: Normal all the test phases are performed. Abort the test is aborted by system. Cancel the test is terminated by operator. executedPhases phaseId = It represents the list of the executed test phases (in case of successful test result, all the test phases will be listed). additionalWords = .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases; they are displayed only for test stopped during it execution. phaseId = .... 482 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked" state, if the diagnostic is intrusive. 2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for test" state. When the test result is: "fail" the object goes in Disabled / Failed operational state; "pass" the object goes in Enabled operational state; "inconclusive" the object returns to the operational state previous to the test or in Enabled operational state. Example of Command Execution Perftest IXLT:NAME=IXLT:0; STOPTEST IXLT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE IXLT STOPTEST IXLT Applicability: Phase 2. Visibility level 2. Command Description: This command allows to terminate the test previously requested; the test can be in progress or in the waiting list (queued). In the first case the process that execute the diagnostic will be interrupted by executing the end phase; in the second case the test will be removed from the waiting list. The validity range of the object address "ixltn" can be found in Appendix A. System Responses: poprosedRepair Action = A list of most probable fail probable causes is shown (max four messages) PERFTEST IXLT NACK: NACK CAUSES: MOTS_NOT_LOCKED The selected object is not in LOCKED administrative state. OTHER_TESTS_RUNNING Other incompatible tests are already running or no more parallel execution of tests possible. STOPTEST IXLT: NAME=IXLT:ixltn; STOPTEST IXLT ACK: STOPTEST IXLT:NAME=IXLT:0; testObject=TEST:<n> A30808-X3247-L230-3-7619 483 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Stoptest IXLT:NAME=IXLT:0; Result TEST: name = TEST:<n> testOutcome = inconclusive mOts = IXLT:0 testTermination = Cancel executedPhases phaseId = It represents the list of the executed test phases; the list is not shown for test in the waiting list (queued). .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases;the list is not shown for test in the waiting list (queued). phaseId = .... STOPTEST IXLT NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNABLE_TO_STOP_TEST The test can not be stopped. 484 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller UNLOCK IXLT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE IXLT UNLOCK IXLT Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "ixltn" can be found in Appendix A. System Responses: Application Guidelines: 1. Unlocking of BTSM causes a full BTS alignment. 2. It is possible to unlock the IXLT card with the status in LOCKED and UNDER TEST. Example of Command Execution Unlock IXLT:NAME=IXLT:0; UNLOCK IXLT: NAME=IXLT:ixltn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. A30808-X3247-L230-3-7619 485 Commands Base Station Controller CML:BSC LICD The LICD object is the interface card for 4 or 12 PCM lines (depending on whether it is implemented by means of a QTLP or a STLP respectively) at 2Mbit/s or 1.544 Mbit/s. The redundancy for this card is provided by the LICDS card and is a N+1 type of redundancy. CREATE LICD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCELICD CREATE LICD Applicability: Phase 2. Visibility level 2. Command Description: This command adds a Line Interface Card (LICD) and sets the threshold values of the system alarm for 2 Mbit/s lines. The validity range of the object address "licdn" can be found in Appendix A. System Responses: CREATE LICD: NAME=LICD:licdn [,ALARMT1=] [,ALARMT2=] [,ALARMT3=] [,ALACOUNT=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The EPWRobject instance must be already equipped in order to submit the CREATE LICD command with instance > 1. UNSUCCESSFUL_EXCEED_OBJECT_NBR LICD instances greater than 8 are allowed only with NTWSNAP_STLP network card. UNSUCCESSFUL_CREATE__DELETE_IN_SEQUENCE The LICD with lower instance number must be EQUIPPED in order to submit the command. When the LICD on the base module (instance 0,1 with the old rack; 0, 1, 2 with the new rack) is created, the LICDS-0 must be already equipped. When the LICDon the expansion module (instance > 1 with the old rack; instance > 2 with the new rack) is created, the LICDS-1 must be already equipped. 486 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. A 2 Mbit/s line is put out of service (disabled) if a line alarm is found set at a period longer than ALARMT2 or ALACOUNT time periods in the ALARMT3 time interval. 2. The line returns in service (enabled) if no alarms is found active for a subsequent ALARMT1 time period. 3. After the creation of the object, the ADMINISTRATIVE state of this object is set at UNLOCKED. The UNLOCK command is NOT required to put this object in service. 4. The timer ALARMT2 must be set shorter than TGUARD (see OPC object) - TSBS (OPC object). Shorter values are useless and can cause a reset procedure at A- interface also for very short link interruption due to the time needed to complete the link realignment. For further information see application guidelines of SET OPC command. 5. The timer ALARMT2 must be set shorter than TSYNC (see BTS object) and TTRAU (BTS and TRAU objects). This is to avoid that, in case of PCM line alarm, the calls are released before the alarm is detected. 6. The SBS detects a PCM link failure depending on the time specied by ALARMT2: if ALARMT2 < 1 sec. and QTLP cards are congured then the detection time is equal to ALARMT2 + 200 ms. Example of Command Execution Create LICD:NAME=LICD:0,ALARMT1=200,ALARMT2=10,ALARMT3=1, ALACOUNT=32; DELETE LICD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD DELETE LICD Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a Line Interface Card (LICD) card previously created with the command CREATE LICD. The validity range of the object address "licdn" can be found in Appendix A. System Responses: DELETE LICD: NAME=LICD:licdn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 487 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Delete LICD:NAME=LICD:1; GET LICD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD GET LICD Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the selected parameters of the Line Interface Card (LICD) related to: the LICD equipped status; the system alarm threshold values for 2 Mbit/s lines. The validity range of the object address "licdn" can be found in Appendix A. System Responses: UNSUCCESSFUL_SUBORDINATE_EQUIPPED There must be no pcm lines connected to that LICD board in order to submit the DELETE LICD command. UNSUCCESSFUL_CREATE__DELETE_IN_SEQUENCE The LICDs with greater instance number must be in NOT EQUIPPED state in order to submit the DELETE LICD. Deletion of LICDs with greater instance number must have been executed before. UNSUCCESSFUL_IN_TEST A diagnostic test is running on the LICD card. UNSUCCESSFUL_INVALID_STATUS Before deleting a LICD, the relative object instance must be in LOCKED state. GET LICD: NAME=LICD:licdn [,REQATTL= ALARMT1, ALARMT2, ALARMT3, ALACOUNT]; GET ACK: NAME: name ALARMT1: alarmTiming1 ALARMT2: alarmTiming2 ALARMT3: alarmTiming3 ALACOUNT: alarmCounter 488 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get LICD:NAME=LICD:0,REQATTL=ALARMT1&ALARMT2&ALARMT3&ALACOUNT; GET LICD BASICS Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD GET LICD BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "licdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get LICD BASICS:NAME=LICD:0; GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET LICD BASICS: NAME=LICD:licdn; GET ACK: NAME: name ALARMT1: alarmTiming1 ALARMT2: alarmTiming2 ALARMT3: alarmTiming3 ALACOUNT: alarmCounter GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. A30808-X3247-L230-3-7619 489 Commands Base Station Controller CML:BSC GET LICD STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCELICD GET LICD STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the LICD object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Unknown Status (UNK). The validity range of the object address "licdn" can be found in Appendix A. System Responses: Application Guidelines: Only sets with raised bits are shown. Example of Command Execution Get LICD STAT:NAME=LICD:0; GETINFO LICD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD GETINFO LICD Applicability: Phase 2. GET LICD STAT: NAME=LICD:licdn; GET LICD STAT ACK: GET LICD STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETINFO LICD: NAME=LICD:licdn; 490 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The states and statuses of the LICD: AST, OST, AVS, CST, STNDBYST, PRS. 2. The licd type. 3. The active NTW copy. 4. The incoming synchronization line, if any. 5. For each PCMline handled by the LICD the command will give the working mode of the circuit (i.e. SINGLE_TRUNK, DOUBLE_TRUNK), the type (PCMB or PCMS), the number, the used trunk (i.e. TRUNK_A, TRUNK_B, BOTH_TRUNK), the administrative/operational states and the availability status. 6. For each PCM line handled the SS7, LAPD, L1CTRLST and X25A links, if any. The validity range of the object address licdn can be found in Appendix A. System Responses: GETINFO LICD ACK: BSC_CONTROLLER -> LMT_LOCAL 11:41:14 22/03/1999 *** INFORMATION *** GETINFO REPORT LICD: NAME = LICD:0 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE STANDBY STATUS: NONE PROCEDURAL STATUS: NONE LICD TYPE: STLP ACTIVE NTW COPY: 0 SYNC PCMC: 5 SYNC TRUNK: TRUNK_A PCMC 0: WORKING MODE: DOUBLE_TRUNK PCMB 0: USED TRUNK: TRUNK_A ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED A30808-X3247-L230-3-7619 491 Commands Base Station Controller CML:BSC AVAILABILITY STATUS: NONE SS7L TIMESLOT: 1 16 22 LPDL TIMESLOT: 2 18 L1CTRLST TIMESLOT: 18 X25A TIMESLOT: 13 PCMB 1: USED TRUNK: TRUNK_B ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE SS7L TIMESLOT: 2 17 25 LPDL TIMESLOT: 1 L1CTRLST TIMESLOT: NONE X25A TIMESLOT: 5 ... ... PCMC 5 WORKING MODE: DOUBLE_TRUNK PCMB 5: USED TRUNK: TRUNK_A ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE SS7L TIMESLOT: 2 13 20 LPDL TIMESLOT: 1 19 L1CTRLST TIMESLOT: 11 X25A TIMESLOT: 15 PCMB 8: USED TRUNK: TRUNK_B ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE SS7L TIMESLOT: 5 14 24 LPDL TIMESLOT: 3 L1CTRLST TIMESLOT: NONE X25A TIMESLOT: 10 492 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller END OF REPORT GETINFO LICD NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack LICD: name = LICD:0 nackCause = <nack cause> Application Guidelines: The attribute SYNC describes the LICD circuit (0 3) and the trunk (A or B) carrying the synchronism if there is one. Example of Command Execution Getinfo LICD:NAME=LICD:0; GETRELATIONSHIP LICD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD GETRELATIONSHIP LICD Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected HMO (Hardware Managed Object); the relationship information consist of all the FMOs (Functional Managed Object) using the HMO service. This information is included in the RELATED_FUNCTIONAL_OBJECTS attribute (ATTID parameter) and the attribute value depends on the working state of the target HMO. NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. GETRELATIONSHIP LICD: NAME=LICD:licdn,ATTID=; A30808-X3247-L230-3-7619 493 Commands Base Station Controller CML:BSC For the LICD object the PCMB, BTSM, LPDLM, BTS, LPDLR, PCMS, TRAU, LPDLS, PCMA and PCMG are the related FMOs. The validity range of the object address "licdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship LICD:NAME=LICD:0,ATTID=RELATED_FUNCTIONAL_OBJECTS; GETSUBO LICD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD GETSUBO LICD Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "licdn" can be found in Appendix A. System Responses: GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected HMO the list of related FMOs is displayed (HMO to FMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. GETSUBO LICD: NAME=LICD:licdn; GETSUBO LICD ACK: The output of the command can be composed by one or more pack with a maximumnumber of ten subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GETSUBO LICD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 494 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Getsubo LICD:NAME=LICD:0; GETTEST LICD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD GETTEST LICD Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the values of all the attributes belonging to a specified test object; the test object is created by the systemas a result of a request to start a test and it is deleted when the test terminates. The validity range of the object address "licdn" can be found in Appendix A. System Responses: GETTEST LICD: NAME=LICD:licdn; GETTEST LICD ACK: GETTEST LICD:NAME=LICD:0; name = TEST:<n> mOts = LICD:0 testState = It can assume one of the following values: not_initialized, idle, initializing, suspended, testing, terminating and disabled. testOutcome = It represents the test result: it can be Inconclusive (meaning-less: that is if the phases already executed were successful) or Fail (if at least one of the executed phases failed). testMonitor phaseId = It is a list of the phases to execute and their status that can be: pass, fail, running or waiting. phaseStatus = phaseId = phaseStatus = .... GETTEST LICD NACK: NACK CAUSES: A30808-X3247-L230-3-7619 495 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Gettest LICD:NAME=LICD:0; LOCK LICD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD LOCK LICD Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "licdn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but , IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock LICD:NAME=LICD:0; NO_SUCH_TEST The test is not active. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. LOCK LICD: NAME=LICD:licdn; LOCK LICD ACK: LOCK LICD NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 496 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PERFTEST LICD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD PERFTEST LICD Applicability: Phase 2. Visibility level 2. Command Description: This command is used to perform a test on the selected LICD object; the test consists of the following phases: Accessibility Test and Card Reset (start phase), FW Protocol and Processor Test (WP1), FW Self Test (WP2), Check Alarm Status (WP3), End Test (end phase). The validity range of the object address "licdn" can be found in Appendix A. System Responses: PERFTEST LICD: NAME=LICD:licdn; PERFTEST LICD ACK: PERFTEST LICD:NAME=LICD:0; testObject=TEST:<n> The test results will be displayed at the end of the test phases. Result TEST: name = TEST:<n> testOutcome = This field represents the test result; one of the following values can be displayed: Pass all the test phases are successfully performed. Inconclusive the test is aborted by the system or the test is terminated by the operator. Fail if at least one of the executed phases fail. mOts = It is the identifier of the hardware object under test. testTermination = It specifies how the test is terminated, it can assume the following values: Normal all the test phases are performed. Abort the test is aborted by system. Cancel the test is terminated by operator. executedPhases phaseId = It represents the list of the executed test phases (in case of successful test result, all the test phases will be listed). additionalWords = .... A30808-X3247-L230-3-7619 497 Commands Base Station Controller CML:BSC Application Guidelines: 1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked" state, if the diagnostic is intrusive. 2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for test" state. When the test result is: "fail" the object goes in Disabled / Failed operational state; "pass" the object goes in Enabled operational state; "inconclusive" the object returns to the operational state previous to the test or in Enabled operational state. Example of Command Execution Perftest LICD:NAME=LICD:0; SET LICD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD SET LICD Applicability: Phase 2. Visibility level 2. failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases; they are displayed only for test stopped during it execution. phaseId = .... poprosedRepair Action = A list of most probable fail probable causes is shown (max four messages) PERFTEST LICD NACK: NACK CAUSES: OTHER_TESTS_RUNNING Other incompatible tests are already running or no more parallel execution of tests possible. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. SET LICD: NAME=LICD:licdn [,ALARMT1=] [,ALARMT2=] [,ALARMT3=] [,ALACOUNT=]; 498 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command modifies the threshold values of the system alarm for 2 Mbit/s lines. The validity range of the object address "licdn" can be found in Appendix A. System Responses: Application Guidelines: 1. A 2 Mbit/s line is put out of service (disabled) if a line alarm is found set at a period longer than ALARMT2 or ALACOUNT time periods in the ALARMT3 time interval. 2. The line returns in service (enabled) if no alarms is found active for a subsequent ALARMT1 time period. 3. The timer ALARMT2 must be set shorter than TGUARD (see OPC object) - TSBS (OPC object). Shorter values are useless and can cause a reset procedure at A- interface also for very short link interruption due to the time needed to complete the link realignment. For further information see application guidelines of SET OPC command. 4. The timer ALARMT2 must be set shorter than TSYNC (see BTS object) and TTRAU (BTS object). This is to avoid that, in case of PCM line alarm, the calls are released before the alarm is detected. 5. The SBS detects a PCM link failure depending on the time specied by ALARMT2: if ALARMT2 < 1 sec. and QTLPcards are congured then the detection time is equal to ALARMT2 + 200 ms. Example of Command Execution Set LICD:NAME=LICD:0,ALARMT1=2,ALARMT2=2,ALARMT3=5,ALACOUNT=2; STOPTEST LICD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD STOPTEST LICD Applicability: Phase 2. Visibility level 2. Command Description: This command allows to terminate the test previously requested; the test can be in progress or in the waiting list (queued). SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. STOPTEST LICD: NAME=LICD:licdn; A30808-X3247-L230-3-7619 499 Commands Base Station Controller CML:BSC In the first case the process that execute the diagnostic will be interrupted by executing the end phase; in the second case the test will be removed from the waiting list. The validity range of the object address "licdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Stoptest LICD:NAME=LICD:0; UNLOCK LICD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD UNLOCK LICD STOPTEST LICD ACK: STOPTEST LICD:NAME=LICD:0; testObject=TEST:<n> Result TEST: name = TEST:<n> testOutcome = inconclusive mOts = LICD:0 testTermination = Cancel executedPhases phaseId = It represents the list of the executed test phases; the list is not shown for test in the waiting list (queued). .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases;the list is not shown for test in the waiting list (queued). phaseId = .... STOPTEST LICD NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNABLE_TO_STOP_TEST The test can not be stopped. UNLOCK LICD: NAME=LICD:licdn; 500 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "licdn" can be found in Appendix A. System Responses: Application Guidelines: It is possible to unlock the LICD card with the status in LOCKED and UNDER TEST. Example of Command Execution Unlock LICD:NAME=LICD:0,FPAR=FORCE; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 501 Commands Base Station Controller CML:BSC LICDS The LICDS object represents the spare LICDcards; two spare LICDcards (one for each BSC frame) exist for the BSC. CREATE LICDS Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICDS CREATE LICDS Applicability: Phase 2. Visibility level 2. Command Description: This command adds a Line Interface Card Spare (LICDS). The validity range of the object address "licdsn" can be found in Appendix A. System Responses: Application Guidelines: After the creation of the object LICDS its administrative state is set at UNLOCKED. The UNLOCK command is NOT required to put the LICDS in service Example of Command Execution Create LICDS:NAME=LICDS:0; CREATE LICDS: NAME=LICDS:licdsn; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_CREATE__DELETE_IN_SEQUENCE The LICDS with lower instance number must be EQUIPPED in order to submit the CREATE LICDS command UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED If the network card is different from NTWSNAP_STLP the additional Power Supply (EPWR) must be already created in order to create LICDS-1. UNSUCCESSFUL_WRONG_LICD_CARD The LICDTYP attribute is not congruent with the NETWTYPE previously assigned to the BSC via a SET BSC command. 502 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DELETE LICDS Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICDS DELETE LICDS Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a Line Interface Card Spare (LICDS) previously created. The validity range of the object address "licdsn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete LICDS:NAME=LICDS:0; DELETE LICDS: NAME=LICDS:licdsn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_CREATE_DELETE_IN_SEQUENCE The LICDS with greater instance number must be in NOT EQUIPPED state in order to submit the DELETE LICDS command. Deletion of LICDS with greater instance number must have been performed before. The LICDS-1 can be deleted only if LICD cards of the expansion module (with instance > 2 if the network card is NTWSNAP_STLP, with instance > 1 otherwise) are in NOT EQUIPPED state. The LICDS-0 can be deleted only if LICD cards of the base module (with instance < 3 if the network card is NTWSNAP_STLP, with instance < 2 otherwise) are in NOT EQUIPPED state. UNSUCCESSFUL_IN_TEST A diagnostic test is running on the LICDS card. UNSUCCESSFUL_INVALID_STATUS Before deleting a LICDS, the relative object instance must be in LOCKED state. A30808-X3247-L230-3-7619 503 Commands Base Station Controller CML:BSC GET LICDS Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICDS GET LICDS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the Line Interface Card Spare (LICDS) equipped status. The validity range of the object address "licdsn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get LICDS:NAME=LICDS:0; GET LICDS STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICDS GET LICDS STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the LICDS object: Administrative State (AST) GET LICDS: NAME=LICDS:licdsn; GET ACK: NAME: name GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET LICDS STAT: NAME=LICDS:licdsn; 504 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Standby Status (STNDBY) Unknown Status (UNK). The validity range of the object address "licdsn" can be found in Appendix A. System Responses: Application Guidelines: Only sets with raised bits are shown. Example of Command Execution Get LICDS STAT:NAME=LICDS:0; GETRELATIONSHIP LICDS Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICDS GETRELATIONSHIP LICDS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected HMO (Hardware Managed Object); the relationship information consist of the all FMOs (Functional Managed Object) using the HMO service. This information is included in the RELATED_FUNCTIONAL_OBJECTS attribute (ATTID parameter) and the attribute value depends on the working state of the target HMO. For the LICDS object the PCMB, BTSM, LPDLM, BTS, LPDLR, PCMS, TRAU, LPDLS, PCMA and PCMG are the related FMOs. The validity range of the object address "licdsn" can be found in Appendix A. GET LICDS STAT ACK: GET LICDS STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETRELATIONSHIP LICDS: NAME=LICDS:licdsn,ATTID=; A30808-X3247-L230-3-7619 505 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Getrelationship LICDS:NAME=LICDS:0,ATTID=RELATED_FUNCTIONAL_OBJECTS; GETSUBO LICDS Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICDS GETSUBO LICDS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "licdsn" can be found in Appendix A. System Responses: Application Guidelines: None. GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected HMO the list of related FMOs is displayed (HMO to FMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. GETSUBO LICDS: NAME=LICDS:licdsn; GETSUBO LICDS ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end there a message is displayed noti- fying the end of the subordinate list. GETSUBO LICDS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 506 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Getsubo LICDS:NAME=LICDS:0; GETTEST LICDS Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICDS GETTEST LICDS Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the values of all the attributes belonging to a specified test object; the test object is created by the systemas a result of a request to start a test and it is deleted when the test terminates. The validity range of the object address "licdsn" can be found in Appendix A. System Responses: GETTEST LICDS: NAME=LICDS:licdsn; GETTEST LICDS ACK: GETTEST LICDS:NAME=LICDS:0; name = TEST:<n> mOts = LICDS:0 testState = It can assume one of the following values: not_initialized, idle, initializing, suspended, testing, terminating and disabled. testOutcome = It represents the test result: it can be Inconclusive (meaning-less: that is if the phases already executed were successful) or Fail (if at least one of the executed phases failed). testMonitor phaseId = It is a list of the phases to execute and their status that can be: pass, fail, running or waiting. phaseStatus = phaseId = phaseStatus = .... GETTEST LICDS NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. A30808-X3247-L230-3-7619 507 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Gettest LICDS:NAME=LICDS:0; LOCK LICDS Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICDS LOCK LICDS Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state "Locked". The validity range of the object address "licdsn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but , IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock LICDS:NAME=LICDS; LOCK LICDS: NAME=LICDS:licdsn; LOCK LICDS ACK: LOCK LICDS NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 508 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PERFTEST LICDS Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICDS PERFTEST LICDS Applicability: Phase 2. Visibility level 2. Command Description: This command is used to perform a test on the selected LICDS object; the test consists of the following phases: Accessibility Test and Card Reset (start phase), FW Protocol and Processor Test (WP1), FW Self Test (WP2), Check Alarm Status (WP3), End Test (end phase). The validity range of the object address "licdsn" can be found in Appendix A. System Responses: PERFTEST LICDS: NAME=LICDS:licdsn; PERFTEST LICDS ACK: PERFTEST LICDS:NAME=LICDS:0; testObject=TEST:<n> The test results will be displayed at the end of the test phases. Result TEST: name = TEST:<n> testOutcome = This field represents the test result; one of the following values can be displayed: Pass all the test phases are successfully performed. Inconclusive the test is aborted by the system or the test is terminated by the operator. Fail if at least one of the executed phases fail. mOts = It is the identifier of the hardware object under test. testTermination = It specifies how the test is terminated, it can assume the following values: Normal all the test phases are performed. Abort the test is aborted by system. Cancel the test is terminated by operator. A30808-X3247-L230-3-7619 509 Commands Base Station Controller CML:BSC Application Guidelines: 1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked" state, if the diagnostic is intrusive. 2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for test" state. When the test result is: "fail" the object goes in Disabled / Failed operational state; "pass" the object goes in Enabled operational state; "inconclusive" the object returns to the operational state previous to the test or in Enabled operational state. Example of Command Execution Perftest LICDS:NAME=LICDS:0; STOPTEST LICDS Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICDS STOPTEST LICDS executedPhases phaseId = It represents the list of the executed test phases (in case of successful test result, all the test phases will be listed). additionalWords = .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases; they are displayed only for test stopped during it execution. phaseId = .... poprosedRepair Action = A list of most probable fail probable causes is shown (max four messages) PERFTEST LICDS NACK: NACK CAUSES: OTHER_TESTS_RUNNING Other incompatible tests are already running or no more parallel execution of tests possible. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. STOPTEST LICDS: NAME=LICDS:licdsn; 510 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 2. Command Description: This command allows to terminate the test previously requested; the test can be in progress or in the waiting list (queued). In the first case the process that execute the diagnostic will be interrupted by executing the end phase; in the second case the test will be removed from the waiting list. The validity range of the object address "licdsn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Stoptest LICDS:NAME=LICDS:0; STOPTEST LICDS ACK: STOPTEST LICDS:NAME=LICDS:0; testObject=TEST:<n> Result TEST: name = TEST:<n> testOutcome = inconclusive mOts = LICDS:0 testTermination = Cancel executedPhases phaseId = It represents the list of the executed test phases; the list is not shown for test in the waiting list (queued). .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases;the list is not shown for test in the waiting list (queued). phaseId = .... STOPTEST LICDS NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNABLE_TO_STOP_TEST The test can not be stopped. A30808-X3247-L230-3-7619 511 Commands Base Station Controller CML:BSC UNLOCK LICDS Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICDS UNLOCK LICDS Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state "Unlocked". The validity range of the object address "licdsn" can be found in Appendix A. System Responses: Application Guidelines: It is possible to unlock the LICD card with the status in LOCKED and UNDER TEST. Example of Command Execution Unlock LICDS:NAME=LICDS:0; UNLOCK LICDS: NAME=LICDS:licdsn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 512 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller LMT-INTERNAL The LMT-INTERNAL object represents the Local Maintenance Terminal. ECHO Command Tree: LMT-INTERNAL ECHO Applicability: Phase 1 and 2. Visibility level 2. Command Description: This command prompts a free string on the user interface. System Responses: None. Application Guidelines: None. Example of Command Execution ECHO:TEXT=The Script has performed all SET commands EXEC Command Tree: LMT-INTERNAL EXEC Applicability: Phase 1 and 2. Visibility level 2. Command Description: This command starts a script execution. System Responses: None. ECHO: TEXT=; EXEC: FILENAME= [,ABORT=] [,DANGEROUS=] [,ERROR=] [,PRIORITY=] [,SYNCHRO=]; A30808-X3247-L230-3-7619 513 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution EXEC:FILENAME=C:\MYSCRIPT.LMT,SYNCHRO=YES; SET Command Tree: LMT-INTERNAL SET Applicability: Phase 1 and 2. Visibility level 2. Command Description: This command configures the CLI System settings. System Responses: None. Application Guidelines: None. Example of Command Execution SET:ABORT=YES,PRIORITY=0; SET: [,ABORT=] [,OUTPUT=] [,CLEAR=] [,SYNCHRO=] [,PRIORITY=]; 514 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller LPDLM The LPDLMobject identifies the logical link used by the BTSE to communicate with the BSC for operation and maintenance purposes. CREATE LPDLM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMLPDLMCREATE LPDLM Applicability: Phase 2. Visibility level 2. Command Description: This command adds a logical LapD connection on a signalling link on Abis interface. It reserves a PCM timeslot for the Abis signalling of the associated BTSM. If optional submultiplexing is used, a LPDLM is associated with a subslot within the slot. Validity ranges of the object addresses "btsmn" and "lpdlmn" can be found in Appendix A. System Responses: CREATE LPDLM: NAME=BTSM:btsmn/LPDLM:lpdlmn ,ABISCH= [,LAPDPOOL=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command.. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The PCMB object instance inserted in the ABISCH attribute must be already equipped. If the network card is different from NTWSNAP or NTWSNAP_STLP two PPLDs must be equipped (one to support the link and one spare for fault recovery). UNSUCCESSFUL_TIME_SLOT_ALREADY_ALLOCATED The timeslot or subslot inserted in the CREATE LPDLM command must be available (neither allocated by other links nor configurated as SUBTSLB object). UNSUCCESSFUL_INVALID_TIME_SLOT The value assigned to the timeSlotNumber field of the ABISCH is not compatible with the PCM line type attribute (parameter PCMTYPE of BSC object). A30808-X3247-L230-3-7619 515 Commands Base Station Controller CML:BSC Application Guidelines: Before configuring a new LPDLM on the BSC side it is necessary to configure the corresponding LPDLE object of the connected BTSE equipment, otherwise the Abis Alignment is going to fail. Example of Command Execution Create LPDLM:NAME=BTSM:0/LPDLM:0,ABISCH=19-19-3,LAPDPOOL=1; DELETE LPDLM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM LPDLM DELETE LPDLM Applicability: Phase 2. Visibility level 2. Command Description: This command deletes an LPDLM instance previously created. Validity ranges of the object addresses "btsmn" and "lpdlmn" can be found in Appendix A. System Responses: UNSUCCESSFUL_LINK_NOT_AVAIL This systemresponse means that the PPLD cards configured in the BSC are insufficient to manage this new LPDLM. UNSUCCESSFUL_VAR_OUT_OF_RANGE If the NTWCARD is set at NTWSN16, the number of different LAPDPOOLs must not exceed the number of equipped PPLDs available (excluding the spare PPLD). If the network card is NTWSNAP or NTWSNAP_STLP the LAPDPOOL cannot be greater than 1. The BS-240XS supports up to 8 LPDLMs. UNSUCCESSFUL_WRONG_PCMB_NUMBER If the BTSM has been created without PCMCON0, the creation of the lpdlm is not allowed. DELETE LPDLM: NAME=BTSM:btsmn/LPDLM:lpdlmn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: 516 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Delete LPDLM:NAME=BTSM:0/LPDLM:0; GET LPDLM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC LPDLM GET LPDLM Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the parameters related to the LPDLM instance spec- ified in the command. Validity ranges of the object addresses "btsmn" and "lpdlmn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get LPDLM:NAME=BTSM:0/LPDLM:0,REQATTL=ABISCH&LAPDPOOL; UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_SUBORDINATE_EQUIPPED An LPDLMobject instance cannot be deleted if an associated SUBTSLB object instance exists. GET LPDLM: NAME=BTSM:btsmn/LPDLM:lpdlmn [,REQATTL= ABISCH, LAPDPOOL]; GET ACK: NAME: name ABISCH: abisChannel LAPDPOOL: lapdPool GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 517 Commands Base Station Controller CML:BSC GET LPDLM BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC LPDLM GET LPDLM BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses "btsmn" and "lpdlmn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get LPDLM BASICS:NAME=BTSM:0/LPDLM:0; GET LPDLM STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMLPDLM GET LPDLM STAT Applicability: Phase 2. Visibility level 0. GET LPDLM BASICS: NAME=BTSM:btsmn/LPDLM:lpdlmn; GET ACK: NAME: name ABISCH: abisChannel LAPDPOOL: lapdPool GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance nust be already equipped. GET LPDLM STAT: NAME=BTSM:btsmn/LPDLM:lpdlmn; 518 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command is used to retrieve the following State/Status attributes related to the LPDLM object: Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Standby Status (STNDBY) Unknown Status (UNK). Validity ranges of the object addresses "btsmn" and "lpdlmn" can be found in Appendix A. System Responses: Application Guidelines: 1. TSYNC should be equal to TTRAU parameter. 2. Only sets with raised bits are shown. Example of Command Execution Get LPDLM STAT:NAME=BTSM:0/LPDLM:0; GETINFO LPDLM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM LPDLM GETINFO LPDLM Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The states and statuses of the LPDLM: OST, AVS, STNDBYST 2. The LPDLM absolute number 3. The TEI number related to the LPDLM 4. The baud rate of the physical lapd GET LPDLM STAT ACK: GET LPDLM STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETINFO LPDLM: NAME=BTSM:btsmn/LPDLM:lpdlmn; A30808-X3247-L230-3-7619 519 Commands Base Station Controller CML:BSC 5. The number and the states and statuses of the PPLD (AST, OST, AVS, CST, STNDBYST and PRS) which handles the LPDLM or the states and statuses of the PPXL (AST, OST, AVS, CST and PRS) which handles the LPDLM 6. The PPLD circuit (or PPXL HDLC circuit and PPXL timeslot) 7. The identity of the subslot on Abis interface 8. The sample pattern transmitted and received by the PPXL/PPLD on the LAPD 9. The sample pattern received and transmitted by the BSC on the PCM line Validity ranges of the object addresses "btsmn" and "lpdlmn" can be found in Appendix A. System Responses GETINFO LPDLM ACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** INFORMATION *** GETINFO REPORT LPDLM: NAME = LPDLM:0 PPLD case: OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE STANDBY STATUS: HOT_STANDBY LPDL ABSOLUTE NR: 5 TEI: 30 BAUD RATE: RATE64KB LAPD POOL: 1 PPLD 1: ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE STANDBY STATUS: PROVIDING_SERVICE PROCEDURAL STATUS: NONE PPLD CIRCUIT: 1 ABIS TIMESLOT: 30 - 1 (PCM NR - TS NR - SUBTS NR) PPXX TX SAMPLE: 0x02 520 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PPXX RX SAMPLE: 0x03 PCMB TX SAMPLE: 0x02 PCMB RX SAMPLE: 0x03 END OF REPORT PPXL case: OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE STANDBY STATUS: HOT_STANDBY LPDL ABSOLUTE NR: 5 TEI: 30 BAUD RATE: RATE16KB LAPD POOL: 1 SERVING PPXL 1: ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE PROCEDURAL STATUS: NONE PPXL HDLC CIRCUIT: 1 PPXL TIMESLOT: 80-3 (TS NR - SUBTS NR) ABIS TIMESLOT: 30-1-0 (PCM NR - TS NR - SUBTS NR) PPXX TX SAMPLE: 0x02 PPXX RX SAMPLE: 0x03 PCMB TX SAMPLE: 0x02 PCMB RX SAMPLE: 0x03 END OF REPORT GETINFO LPDLM NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack LPDLM: name = LPDLM:0 A30808-X3247-L230-3-7619 521 Commands Base Station Controller CML:BSC nackCause = <nack cause> Application Guidelines: None. Example of Command Execution Getinfo LPDLM:NAME=BTSM:0/LPDLM:0; GETRELATIONSHIP LPDLM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM LPDLM GETRELATIONSHIP LPDLM Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of the all HMOs (Hardware Managed Object) supporting the FMO functionality. For the LPDLMobject the related HMOs are the following: LICD/LICDS, EPWR, PPLD, PWRD, MPCC, TDPC, MEMT, NTW and PPXL. Validity ranges of the object addresses "btsmn" and "lpdlmn" can be found in Appendix A. System Responses: NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. GETRELATIONSHIP LPDLM: NAME=BTSM:btsmn/LPDLM:lpdlmn; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: 522 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Getrelationship LPDLM:NAME=BTSM:0/LPDLM:0; GETSUBO LPDLM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM LPDLM GETSUBO LPDLM Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. Validity ranges of the object addresses "btsmn", and "lpdlmn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo LPDLM:NAME=BTSM:0/LPDLM:0; UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. GETSUBO LPDLM: NAME=BTSM:btsmn/LPDLM:lpdlmn; GETSUBO LPDLM ACK: The output of the command can be composed by one or more pack with a maximumnumber of ten subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GET LPDLM STATUS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 523 Commands Base Station Controller CML:BSC SET LPDLM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM LPDLM SET LPDLM Applicability: Phase 2. Visibility level 2. Command Description: This command allows the operator to modify the parameters related to a logical LapD connection on a signalling link on Abis interface. Validity ranges of the object addresses "btsmn" and "lpdlmn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Set LPDLM:NAME=BTSM:0/LPDLM:0,LAPDPOOL=4; SET LPDLM: NAME=BTSM:btsmn/LPDLM:lpdlmn [,LAPDPOOL=]; SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_LINK_NOT_AVAIL This systemresponse means that the PPLD cards configured in the BSC are insufficient to manage this new LPDLM. UNSUCCESSFUL_VAR_OUT_OF_RANGE If the NTWCARD is set at NTWSN16, the number of different LAPDPOOLs must not exceed the number of equipped PPLDs available (excluding the PPLD spare). If the network card is NTWSNAP or NTWSNAP_STLP the LAPDPOOL cannot be greater than 1. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED If the network card is different from NTWSNAP or NTWSNAP_STLP two PPLDs must be equipped (one to support the link and one spare for fault recovery). 524 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller LPDLMTD The LPDLMTD object identifies the logical link used by the BTSC to communicate with the BSC for operation and maintenance purposes. CREATE LPDLMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD LPDLMTD CREATE LPDLMTD Applicability: Phase 2. Visibility level 2. Command Description: This command adds a logical LapD connection on a signalling link on Abis interface. It reserves a PCMtimeslot for the Abis signalling of the associated BTSMTD. If optional submultiplexing is used, a LPDLMTD is associated with a subslot within the slot. Validity ranges of the object addresses "btsmtdn" and "lpdlmtdn" can be found in Appendix A. System Responses: CREATE LPDLMTD: NAME=BTSMTD:btsmtdn/LPDLMTD:lpdlmtdn ,ABISCH=; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command.. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The PCMB object instance inserted in the ABISCH attribute must be already equipped. The BTSMTD instance associated to LPDLMTD must be already created UNSUCCESSFUL_TIME_SLOT_ALREADY_ALLOCATED The timeslot or subslot inserted in the CREATE LPDLMTD command must be available (neither allocated by other links nor configurated as SUBTSLB object). UNSUCCESSFUL_INVALID_TIME_SLOT The value assigned to the timeSlotNumber field of the ABISCH is not compatible with the PCM line type attribute (parameter PCMTYPE of BSC object). A30808-X3247-L230-3-7619 525 Commands Base Station Controller CML:BSC Application Guidelines: Before configuring a new LPDLMTD on the BSC side it is necessary to configure the corresponding LPDLE object of the connected BTSE equipment, otherwise the Abis Alignment is going to fail. Example of Command Execution Create LPDLMTD:NAME=BTSMTD:0/LPDLMTD:0,ABISCH=19-19-3; DELETE LPDLMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD LPDLMTD DELETE LPDLMTD Applicability: Phase 2. Visibility level 2. Command Description: This command deletes an LPDLMTD instance previously created. Validity ranges of the object addresses "btsmtdn" and "lpdlmtdn" can be found in Appendix A. System Responses: UNSUCCESSFUL_LINK_NOT_AVAIL This systemresponse means that the PPXT cards configured in the BSC are insufficient to manage this new LPDLMTD. UNSUCCESSFUL_WRONG_PCMB_NUMBER If the BTSMTD has been created without PCMCON0, the creation of the lpdlmtd is not allowed. DELETE LPDLMTD: NAME=BTSMTD:btsmtdn/LPDLMTD:lpdlmtdn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_SUBORDINATE_EQUIPPED An LPDLMTD object instance cannot be deleted if an associ- ated SUBTSLB object instance exists. The TRXTDs instances associated to LPDLMTD must be previously deleted. 526 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Delete LPDLMTD:NAME=BTSMTD:0/LPDLMTD:0; GET LPDLMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC BTSMTD ---> LPDLMTD GET LPDLMTD Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the parameters related to the LPDLMTD instance specified in the command. Validity ranges of the object addresses "btsmtdn" and "lpdlmtdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get LPDLMTD:NAME=BTSMTD:0/LPDLMTD:0,REQATTL=ABISCH; GET LPDLMTD: NAME=BTSMTD:btsmtdn/LPDLMTD:lpdlmtdn [,REQATTL= ABISCH; GET ACK: NAME: name ABISCH: abisChannel GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 527 Commands Base Station Controller CML:BSC GET LPDLMTD BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC BTSMTD ---> LPDLMTD GET LPDLMTD BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses "btsmtdn" and "lpdlmtdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get LPDLMTD BASICS:NAME=BTSMTD:0/LPDLMTD:0; GET LPDLMTD STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTDLPDLMTD GET LPDLMTD STAT Applicability: Phase 2. Visibility level 0. GET LPDLMTD BASICS: NAME=BTSMTD:btsmtdn/LPDLMTD:lpdlmtdn; GET ACK: NAME: name ABISCH: abisChannel GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance nust be already equipped. GET LPDLMTD STAT: NAME=BTSMTD:btsmtdn/LPDLMTD:lpdlmtdn; 528 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command is used to retrieve the following State/Status attributes related to the LPDLMTD object: Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Standby Status (STNDBY) Unknown Status (UNK). Validity ranges of the object addresses "btsmtdn" and "lpdlmtdn" can be found in Appendix A. System Responses: Application Guidelines: 1. TSYNC should be equal to TTRAU parameter. 2. Only sets with raised bits are shown. Example of Command Execution Get LPDLMTD STAT:NAME=BTSMTD:0/LPDLMTD:0; GETINFO LPDLMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD LPDLMTD GETINFO LPDLMTD Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The states and statuses of the LPDLMTD: OST, AVS, STNDBYST 2. The LPDLMTD absolute number 3. The TEI number related to the LPDLMTD 4. The baud rate of the physical lapd GET LPDLMTD STAT ACK: GET LPDLM STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETINFO LPDLMTD: NAME=BTSMTD:btsmtdn/LPDLMTD:lpdlmtdn; A30808-X3247-L230-3-7619 529 Commands Base Station Controller CML:BSC 5. The number and the states and statuses of the PPXT (AST, OST, AVS, CST, STNDBYST and PRS) which handles the LPDLMTD 6. The PPXT circuit 7. The identity of the subslot on Abis interface 8. The sample pattern transmitted and received by the PPXT on the LAPD 9. The sample pattern received and transmitted by the BSC on the PCM line Validity ranges of the object addresses "btsmtdn" and "lpdlmtdn" can be found in Appendix A. System Responses GETINFO LPDLMTD ACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/2002 *** INFORMATION *** GETINFO REPORT LPDLM: NAME = LPDLMTD:0 OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE STANDBY STATUS: HOT_STANDBY LPDLTD ABSOLUTE NR: 5 TEI: 30 BAUD RATE: RATE64KB PPXT 1: ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE STANDBY STATUS: PROVIDING_SERVICE PROCEDURAL STATUS: NONE PPXT CIRCUIT: 1 ABIS TIMESLOT: 30 - 1 (PCM NR - TS NR - SUBTS NR) PPXT TX SAMPLE: 0x02 PPXT RX SAMPLE: 0x03 PCMB TX SAMPLE: 0x02 PCMB RX SAMPLE: 0x03 530 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller END OF REPORT GETINFO LPDLMTD NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack LPDLMTD: name = LPDLMTD:0 nackCause = <nack cause> Application Guidelines: None. Example of Command Execution Getinfo LPDLMTD:NAME=BTSMTD:0/LPDLMTD:0; GETRELATIONSHIP LPDLMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD LPDLMTD GETRELATIONSHIP LPDLMTD Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of the all HMOs (Hardware Managed Object) supporting the FMO functionality. For the LPDLMTD object the related HMOs are the following: LICD/LICDS, EPWR, PWRD, MPCC, TDPC, MEMT, NTW and PPXT. Validity ranges of the object addresses "btsmtdn" and "lpdlmtdn" can be found in Appendix A. NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. GETRELATIONSHIP LPDLMTD: NAME=BTSMTD:btsmttdn/LPDLMTD:lpdlmtdn; A30808-X3247-L230-3-7619 531 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Getrelationship LPDLMTD:NAME=BTSMTD:0/LPDLMTD:0; GETSUBO LPDLMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD LPDLMTD GETSUBO LPDLMTD Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. Validity ranges of the object addresses "btsmtdn", and "lpdlmtdn" can be found in Appendix A. System Responses: GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. GETSUBO LPDLMTD: NAME=BTSMTD:btsmtdn/LPDLMTD:lpdlmtdn; GETSUBO LPDLMTD ACK: The output of the command can be composed by one or more pack with a maximumnumber of ten subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GET LPDLMTD STATUS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 532 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Getsubo LPDLMTD:NAME=BTSMTD:0/LPDLMTD:0; A30808-X3247-L230-3-7619 533 Commands Base Station Controller CML:BSC LPDLR The LPDLRobject represents the logical link used by a TRX to communicate with a BSC for telecommunication purposes. GET LPDLR STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX LPDLR GET LPDLR STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the BTS object: Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Unknown Status (UNK). Validity ranges of the object addresses btsmn, "btsn", "trxn" and lpdlrn can be found in Appendix A. System Responses: Application Guidelines: 1. TSYNC should be equal to TTRAU parameter. 2. Only sets with raised bits are shown. Example of Command Execution Get LPDLR STAT:NAME=BTSM:0/BTS:0/TRX:0/LPDLR:0; GET LPDLR STAT: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn/LPDLR:lpdlrn; GET LPDLR STAT ACK: GET LPDLR STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 534 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETINFO LPDLR Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX LPDLR GETINFO LPDLR Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The states and statuses of the LPDLR:OST, AVS. 2. The LPDLR absolute number. 3. The TEI number related to the LPDLR. 4. The Primary and the Current position of the LPDLM associated. 5. The baud rate of the physical lapd. 6. The Lapd pool number. 7. The states and statuses of the PPLD (AST, OST, AVS, CST, STNDBYST and PRS) which handles the LPDLR or the states and statuses of the PPXL (AST, OST, AVS, CST and PRS) which handles the LPDLR. 8. The PPLD circuit (or PPXL HDLC circuit and PPXL timeslot). 9. The identity of the subslot on Abis interface. Validity ranges of the object addresses btsmn, "btsn", "trxn" and lpdlrn can be found in Appendix A. System Responses: GETINFO LPDLR ACK: BSC_CONTROLLER -> LMT_LOCAL 16:42:35 20/01/1992 *** INFORMATION *** GET INFO REPORT LPDLR:0 NAME = LPDLR:0 PPLD case: GETINFO LPDLR: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn/LPDLR:lpdlrn; i If the LPDLMassociated to the LPDLR is out of service, the following information is not shown in the Getinfo LPDLR command response: - lpdlm current position; - baud rate; - lapd pool number; - abis timeslot (pcmline, tslt, subslot) - serving PPXL timeslot and serving PPXL subtimeslot; - PPLD information. A30808-X3247-L230-3-7619 535 Commands Base Station Controller CML:BSC OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE LPDL ABSOLUTE NR: 12 TEI: 2 LPDLM PRIMARY POSITION: 0 LPDLM CURRENT POSITION: 0 BAUD RATE: RATE64KB LAPD POOL: 0 PPLD 3: ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE STANDBY STATUS: PROVIDING_SERVICE PROCEDURAL STATUS: NONE PPLD CIRCUIT: 2 ABIS TIMESLOT: 30 - 21 (PCM NR-TS NR-SUBTS NR) END OF REPORT PPXL case: OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE LPDL ABSOLUTE NR: 12 TEI: 2 LPDLM PRIMARY POSITION: 0 LPDLM CURRENT POSITION: 0 BAUD RATE: RATE64KB LAPD POOL: 0 SERVING PPXL 3: 536 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE PROCEDURAL STATUS: NONE PPXL HDLC CIRCUIT: 1 PPXL TIMESLOT: 2 ABIS TIMESLOT: 30 - 21 (PCM NR-TS NR-SUBTS NR) END OF REPORT GETINFO LPDLR NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack LPDLR: name = LPDLR:0 nackCause = <nack cause> Application Guidelines: None. Example of Command Execution Getinfo LPDLR:NAME=BTSM:0/BTS:0/TRX:0/LPDLR:0; GETRELATIONSHIP LPDLR Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX LPDLR GETRELATIONSHIP LPDLR NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. GETRELATIONSHIP LPDLR: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn/LPDLR:lpdlrn; A30808-X3247-L230-3-7619 537 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of all the HMOs (Hardware Managed Object) supporting the FMO functionality. For the LPDLR object the related HMOs are the following: LICD/LICDS, EPWR, PPLD, PWRD, MPCC, TDPC, MEMT, NTW and PPXL. Validity ranges of the object addresses btsmn, "btsn", "trxn" and lpdlrn can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship LPDLR:NAME=BTSM:0/BTS:0/TRX:0/LPDLR:0; GETSUBO LPDLR Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX LPDLR GETSUBO LPDLR Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. GETSUBO LPDLR: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn/LPDLR:lpdlrn; 538 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Validity ranges of the object addresses btsmn, "btsn", "trxn" and lpdlrn can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo LPDLR:NAME=BTSM:0/BTS:0/TRX:0/LPDLR:0; GETSUBO LPDLR ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GETSUBO LPDLR NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The selected object must be created. A30808-X3247-L230-3-7619 539 Commands Base Station Controller CML:BSC LPDLRTD The LPDLRTD object represents the logical link used by a TRXTD to communicate with a BSC for telecommunication purposes. GET LPDLRTD STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD LPDLRTD GET LPDLRTD STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the LPDLRTD object: Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Unknown Status (UNK). Validity ranges of the object addresses btsmtdn, "btstdn", "trxtdn" and lpdlrtdn can be found in Appendix A. System Responses: Application Guidelines: None Example of Command Execution Get LPDLRTD STAT:NAME=BTSMTD:0/BTSTD:0/TRXTD:0/LPDLRTD:0; GET LPDLRTD STAT: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn/ LPDLRTD:lpdlrtdn; GET LPDLRTD STAT ACK: GET LPDLRTD STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 540 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETINFO LPDLRTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD LPDLRTD GETINFO LPDLRTD Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The states and statuses of the LPDLRTD:OST, AVS. 2. The LPDL absolute number. 3. The TEI number related to the LPDLRTD. 4. The Primary and the Current position of the LPDLMTD associated. 5. The baud rate of the physical lapd. 6. The states and statuses of the PPXT (AST, OST, AVS, CST, STNDBYST and PRS) which handles the LPDLRTD. 7. The PPXT circuit. 8. The identity of the subslot on Abis interface. 9. The PCMB where the link is created. its timeslot and subtimeslot; Validity ranges of the object addresses btsmtdn, "btstdn", "trxtdn" and lpdlrtdn can be found in Appendix A. System Responses: GETINFO LPDLRTD ACK: BSC_CONTROLLER -> LMT_LOCAL 16:42:35 20/01/1992 *** INFORMATION *** GET INFO REPORT LPDLRTD:0 NAME = LPDLRTD:0 OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE LPDL ABSOLUTE NR: 12 TEI : 2 LPDLMTD PRIMARY POSITION: 0 LPDLMTD CURRENT POSITION: 0 GETINFO LPDLRTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn/ LPDLRTD:lpdlrtdn; A30808-X3247-L230-3-7619 541 Commands Base Station Controller CML:BSC BAUD RATE: RATE64KB PPXT 3: ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE STANDBY STATUS: PROVIDING_SERVICE PROCEDURAL STATUS: NONE PPXT CIRCUIT: 2 ABIS TIMESLOT: 30 - 21 (PCM NR-TS NR-SUBTS NR) END OF REPORT GETINFO LPDLRTD NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack LPDLRTD: name = LPDLRTD:0 nackCause = <nack cause> Application Guidelines: None. Example of Command Execution Getinfo LPDLRTD:NAME=BTSMTD:0/BTSTD:0/TRXTD:0/LPDLRTD:0; GETRELATIONSHIP LPDLRTD NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. GETRELATIONSHIP LPDLRTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn/LPD LRTD:lpdlrtdn; 542 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD LPDLRTD GETRELATIONSHIP LPDLRTD Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of all the HMOs (Hardware Managed Object) supporting the FMO functionality. For the LPDLRTD object the related HMOs are the following: LICD/LICDS, EPWR, PPLD, PWRD, MPCC, TDPC, MEMT, NTW and PPXT. Validity ranges of the object addresses btsmtdn, "btstdn", "trxtdn" and lpdlrtdn can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship LPDLRTD:NAME=BTSMTD:0/BTSTD:0/TRXTD:0/LPDLRTD:0; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. A30808-X3247-L230-3-7619 543 Commands Base Station Controller CML:BSC GETSUBO LPDLRTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD LPDLRTD GETSUBO LPDLRTD Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. Validity ranges of the object addresses btsmtdn, "btstdn", "trxtdn" and lpdlrtdn can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo LPDLRTD:NAME=BTSMTD:0/BTSTD:0/TRXTD:0/LPDLRTD:0; GETSUBO LPDLRTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn/ LPDLRTD:lpdlrtdn; GETSUBO LPDLRTD ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GETSUBO LPDLR NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The selected object must be created. 544 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller LPDLS The LPDLS object identifies the logical link used by the TRAU to communicate with the BSC for operation and maintenance purposes. CREATE LPDLS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU LPDLS CREATE LPDLS Applicability: Phase 2. Visibility level 2. Command Description: This command adds a logical LAPD connection on a signalling link on Asub interface. It reserves a PCM timeslot for the Asub signalling of the associated TRAU. Validity ranges of the object addresses "traun" and "lpdlsn" can be found in Appendix A. System Responses: CREATE LPDLS: NAME=TRAU:traun/LPDLS:lpdlsn, ASUBCH=, [,LAPDPOOL=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The PCMS object instance inserted in the ASUBCH attribute must be already equipped. If the network card is different fromNTWSNAPor NTWSNAP_STLP two PPLDs must be equipped (one to support the link and one spare for fault recovery). UNSUCCESSFUL_TIME_SLOT_ALREADY_ALLOCATED The timeslot or subslot inserted in the create LPDLScommand must be not allocated by other links. INVALID_ATTRIBUTE_VALUE Every PCMS can support only one LPDLS. A30808-X3247-L230-3-7619 545 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Create LPDLS:NAME=TRAU:0/LPDLS:0,ASUBCH=0-1-3,LAPDPOOL=2; DELETE LPDLS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC LPDLS DELETE LPDLS Applicability: Phase 2. Visibility level 2. Command Description: This command deletes an LPDLS instance previously created. Validity ranges of the object addresses "traun" and "lpdlsn" can be found in Appendix A. System Responses: UNSUCCESSFUL_INVALID_TIME_SLOT The value assigned to the timeSlotNumber field of the ASUBCH is not compatible with the PCM line type attribute (parameter PCMTYPE of BSC object). It is not possible to create a 16 kb/sec LPDLS. UNSUCCESSFUL_LINK_NOT_AVAIL This systemresponse means that the PPLD cards configured in the BSC are insufficient to manage this new LPDLS. UNSUCCESSFUL_VAR_OUT_OF_RANGE If the NTWCARD is set at NTWSN16, the number of different LAPD- POOLs must not exceed the number of equipped PPLDs available (excluding the PPLD spare). If the network card is NTWSNAP or NTWSNAP_STLP the LAPDPOOL cannot be greater than 1. DELETE LPDLS: NAME=TRAU:traun/LPDLS:lpdlsn, DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_SUBORDINATE_EQUIPPED The TRAU object instance associated to the LPDLS object instance must be previously deleted. 546 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Delete LPDLS:NAME=TRAU:0/LPDLS:0; GET LPDLS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU LPDLS GET LPDLS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the parameters related to the LPDLS instance speci- fied in the command. Validity ranges of the object addresses "traun" and "lpdlsn" can be found in Appendix A.. System Responses: Application Guidelines: None. Example of Command Execution Get LPDLS:NAME=TRAU:0/LPDLS:0,REQATTL=ASUBCH&LAPDPOOL; GET LPDLS: NAME=TRAU:traun/LPDLS:lpdlsn [,REQATTL=ASUBCH, LAPDPOOL]; GET ACK: NAME: name ASUBCH: asubChannel LAPDPOOL: lapdPool GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped A30808-X3247-L230-3-7619 547 Commands Base Station Controller CML:BSC GET LPDLS BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU LPDLS GET LPDLS BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses "traun" and "lpdlsn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get LPDLS BASICS:NAME=TRAU:0/LPDLS:0; GET LPDLS STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU LPDLS GET LPDLS STAT Applicability: Phase 2. Visibility level 0. GET LPDLS BASICS: NAME=TRAU:traun/LPDLS:lpdlsn; GET ACK: NAME: name ASUBCH: asubChannel LAPDPOOL: lapdPool GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. GET LPDLS STAT: NAME=TRAU:traun/LPDLS:lpdlsn, 548 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command is used to retrieve the following State/Status attributes related to the LPDLS object: Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Unknown Status (UNK). Validity ranges of the object addresses "traun" and "lpdlsn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get LPDLS STAT:NAME=TRAU:0/LPDLS:0; GETINFO LPDLS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU LPDLS GETINFOLPDLS Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The states and statuses of the LPDLS: OST, AVS. 2. The LPDLS absolute number. 3. The TEI number related to the LPDLS. 4. The baud rate of the physical lapd. 5. The LAPD pool number. 6. The states and statuses of the PPLD (AST, OST, AVS, CST, STNDBYST and PRS) which handles the LPDLR or the states and the statuses of the PPXL (AST, OST, AVS, CST and PRS) which handles the LPDLR. 7. The PPLD circuit (or PPXL HDLC circuit and PPXL timeslot). GET LPDLS STAT ACK: GET LPDLS STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETINFO LPDLS: NAME=TRAU:traun/LPDLS:lpdlsn, A30808-X3247-L230-3-7619 549 Commands Base Station Controller CML:BSC 8. The identity of the subslot on Asub interface. 9. The sample pattern transmitted and received by the PPXL/PPLD on the LAPD. 10. The sample pattern received and transmitted by the BSC on the PCM line. Validity ranges of the object addresses "traun" and "lpdlsn" can be found in Appendix A. System Responses: GETINFO LPDLS ACK: BSC_CONTROLLER -> LMT_LOCAL 11:41:14 22/03/1999 *** INFORMATION *** GET INFO REPORT: NAME = LPDLS:0 PPLD case: OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE LPDL ABSOLUTE NR: 1 TEI: 2 BAUD RATE: RATE64KB LAPD POOL: 1 PPLD 1: ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE STANDBY STATUS: PROVIDING_SERVICE PROCEDURAL STATUS: NONE PPLD CIRCUIT: 0 ASUB TIMESLOT: 1 - 10 (PCM NR - TS NR - SUBTS NR) PPXX TX SAMPLE: 0x02 PPXX RX SAMPLE: 0x03 PCMS TX SAMPLE: 0x02 PCMS RX SAMPLE: 0x03 END OF REPORT 550 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PPXL case: OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE LPDL ABSOLUTE NR: 1 TEI: 2 BAUD RATE: RATE64KB LAPD POOL: 1 SERVING PPXL 1: ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE PROCEDURAL STATUS: NONE PPXL HDLC CIRCUIT: 1 PPXL TIMESLOT: 0 ASUB TIMESLOT: 1-10 (PCM NR - TS NR - SUBTS NR) PPXX TX SAMPLE: 0x02 PPXX RX SAMPLE: 0x03 PCMS TX SAMPLE: 0x02 PCMS RX SAMPLE: 0x03 END OF REPORT GETINFO LPDLS NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack LPDLS: name = LPDLS:0 nackCause = <nack cause> NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 551 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Getinfo LPDLS:NAME=TRAU:0/LPDLS:0; GETRELATIONSHIP LPDLS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU LPDLS GETRELATIONSHIP LPDLS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of the all HMOs (Hardware Managed Object) supporting the FMO functionality. For the LPDLS object the related HMOs are the following: LICD/LICDS, EPWR, BSMS, TPWR, PPLD, PWRD, MPCC, TDPC, MEMT, NTW and PPXL. Validity ranges of the object addresses "traun" and "lpdlsn" can be found in Appendix A. System Responses: Application Guidelines: None. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. GETRELATIONSHIP LPDLS: NAME=TRAU:traun/LPDLS:lpdlsn; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. 552 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Getrelationship LPDLS:NAME=TRAU:0/LPDLS:0; GETSUBO LPDLS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU LPDLS GETSUBO LPDLS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. Validity ranges of the object addresses "traun" and "lpdlsn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo LPDLS:NAME=TRAU:0/LPDLS:0; SET LPDLS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU LPDLS SET LPDLS GETSUBO LPDLS: NAME=TRAU:traun/LPDLS:lpdlsn, GETSUBO LPDLS ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GET LPDLS STATUS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SET LPDLS: NAME=TRAU:traun/LPDLS:lpdlsn [,LAPDPOOL=]; A30808-X3247-L230-3-7619 553 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 2. Command Description: This command allows the operator to modify the parameters related to the logical LAPD connection on a signalling link on Asub interface. Validity ranges of the object addresses "traun" and "lpdlsn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Set LPDLS:NAME=TRAU:0/LPDLS:0,LAPDPOOL=2; SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_LINK_NOT_AVAIL This systemresponse means that the PPLD cards configured in the BSC are insufficient to manage this new LPDLS. UNSUCCESSFUL_VAR_OUT_OF_RANGE If the NTWCARD is set at NTWSN16, the number of different LAPDPOOLs must not exceed the number of equipped PPLDs available (excluding the spare PPLD). If the network card is NTWSNAP or NTWSNAP_STLP the LAPDPOOL cannot be greater than 1. 554 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller MEL The MEL (Managed Element) object represents the entry point of the addressing of the BSS; it is used to distinguish different BSCs at the same Radio Commander. GET MEL Command Tree: MANAGED-ELEMENT MEL GET MEL Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the parameter values selected by means of the REQATTL attribute. The validity range of the object address meln can be found in Appendix A. System Responses: Application Guidelines: 1. Using the LMT dashboard, when the PC time is modied, the NE time is also modied and, when submitting the GET MEL command, the NE time is set back to the original MEL time. This is the only way to correctly reset the NE time. 2. The LMT date range is narrower than BSC range: the LMT restriction on the date is due to the win32 API that cannot support dates greater than 01/19/2038. For this reason, if the user submits a date greater than 01/19/2038 by means of the ETIME parameter of the SET MEL command and subsequently retrieves it (by means of a GET MEL command) the date displayed in the ETIME parameter of the latter command will be different. Example of Command Execution Get MEL:NAME=MEL:0,REQATTL=MELID&ETIME&VER; GET MEL NAME=MEL:meln [,REQATTL=MELID, ETIME, VER]; GET ACK: NAME: name MELID: managedElementId ETIME: externalTime VER: version GET NACK: NACK CAUSES: None. A30808-X3247-L230-3-7619 555 Commands Base Station Controller CML:BSC GET MEL BASICS Command Tree: MANAGED-ELEMENT MEL GET MEL BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address meln can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get MEL BASICS:NAME=MEL:0; SET MEL Command Tree: MANAGED-ELEMENT MEL SET MEL Applicability: Phase 2. Visibility level 2. Command Description: The validity range of the object address meln can be found in Appendix A. GET MEL BASICS: NAME=MEL:meln; GET ACK: NAME: name MELID: managedElementId ETIME: externalTime GET NACK: NACK CAUSES: None. SET MEL: NAME=MEL:meln [,MELID=] [,ETIME=]; 556 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: 1. All the sub-elds of the ETIME parameter must be set by the operator. 2. The LMT date range is narrower than BSC range: the LMT restriction on the date is due to the win32 API that cannot support dates greater than 01/19/2038. For this reason, if the user submits a date greater than 01/19/2038 by means of the ETIME parameter of the SET MEL command and subsequently retrieves it (by means of a GET MEL command) the date displayed in the ETIME parameter of the latter command will be different. 3. If MELID parameter is changed, it is necessary to performa BSC Bring-up after the SET MEL command. Example of Command Execution Set MEL:NAME=MEL:0,MELID=15,ETIME=1-55-00-2-2-2002; SET ACK: SET NACK: NACK CAUSES: None. A30808-X3247-L230-3-7619 557 Commands Base Station Controller CML:BSC MEMT The MEMT object contains a 2 Mbyte RAM memory bank with direct addressing; it has redundancy of the active/standby type and each copy can be attained by both copies of TDPC. GET MEMT STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE MEMT GET MEMT STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the MEMT object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Standby Status (STNDBY) Unknown Status (UNK). The validity range of the object address "memtn" can be found in Appendix A. System Responses: Application Guidelines: Only sets with raised bits are shown. Example of Command Execution Get MEMT STAT:NAME=MEMT:0; GET MEMT STAT: NAME=MEMT:memtn; GET MEMT STAT ACK: GET MEMT STAT NACK: NACK CAUSES: None. 558 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETRELATIONSHIP MEMT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE MEMT GETRELATIONSHIP MEMT Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected HMO (Hardware Managed Object); the relationship information consist of the all FMOs (Functional Managed Object) using the HMO service. This information is included in the RELATED_FUNCTIONAL_OBJECTS attribute (ATTID parameter) and the attribute value depends on the working state of the target HMO. For the MEMT object the MEL is the related FMO. The validity range of the object address "memtn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship MEMT:NAME=MEMT:0,ATTID=RELATED_FUNCTIONAL_OBJECTS; GETSUBO MEMT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE MEMT GETSUBO MEMT GETRELATIONSHIP MEMT: NAME=MEMT:memtn,ATTID=; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected HMO the list of related FMOs is displayed (HMO to FMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. GETSUBO MEMT: NAME=MEMT:memtn; A30808-X3247-L230-3-7619 559 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "memtn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo MEMT:NAME=MEMT:0; GETTEST MEMT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE MEMT GETTEST MEMT Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the values of all the attributes belonging to a specified test object; the test object is created by the systemas a result of a request to start a test and it is deleted when the test terminates. The validity range of the object address "memtn" can be found in Appendix A. System Responses: GETSUBO MEMT ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end there a message is displayed noti- fying the end of the subordinate list. GETSUBO MEMT NACK: NACK CAUSES: None. GETTEST MEMT: NAME=MEMT:memtn; GETTEST MEMT ACK: GETTEST MEMT:NAME=MEMT:0; name = TEST:<n> 560 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Gettest MEMT:NAME=MEMT:0; LOCK MEMT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE MEMT LOCK MEMT Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The command can be rejected due to high criticity of the system state. The validity range of the object address "memtn" can be found in Appendix A. mOts = MEMT:0 testState = It can assume one of the following values: not_initialized, idle, initializing, suspended, testing, terminating and disabled. testOutcome = It represents the test result: it can be Inconclusive (meaning-less: that is if the phases already executed were successful) or Fail (if at least one of the executed phases failed). testMonitor phaseId = It is a list of the phases to execute and their status that can be: pass, fail, running or waiting. phaseStatus = phaseId = phaseStatus = .... GETTEST LICDS NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. LOCK MEMT: NAME=MEMT:memtn; A30808-X3247-L230-3-7619 561 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock MEMT:NAME=MEMT:0; PERFTEST MEMT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE MEMT PERFTEST MEMT Applicability: Phase 2. Visibility level 2. Command Description: This command is used to perform a test on the selected MEMT object; the test consists of the following phases: Accessibility Test (start phase), DUAM Test - MPCC Side (WP1), DUAM Test - TDPC Side (WP2), End Test (end phase). The validity range of the object address "memtn" can be found in Appendix A. System Responses: LOCK MEMT ACK: LOCK MEMT NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. CRITICAL_ALARM_REJECTED The command has been rejected due to high criticity of the system state. PERFTEST MEMT: NAME=MEMT:memtn; PERFTEST MEMT ACK: PERFTEST MEMT:NAME=MEMT:0; testObject=TEST:<n> 562 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked" state, if the diagnostic is intrusive. 2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for test" state. When the test result is: "fail" the object goes in Disabled / Failed operational state; "pass" the object goes in Enabled operational state; "inconclusive" the object returns to the operational state previous to the test or in Enabled operational state. The test results will be displayed at the end of the test phases. Result TEST: name = TEST:<n> testOutcome = This field represents the test result; one of the following values can be displayed: Pass all the test phases are successfully performed. Inconclusive the test is aborted by the system or the test is terminated by the operator. Fail if at least one of the executed phases fail. mOts = It is the identifier of the hardware object under test. testTermination = It specifies how the test is terminated, it can assume the following values: Normal all the test phases are performed. Abort the test is aborted by system. Cancel the test is terminated by operator. executedPhases phaseId = It represents the list of the executed test phases (in case of successful test result, all the test phases will be listed). additionalWords = .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases; they are displayed only for test stopped during it execution. phaseId = .... poprosedRepair Action = A list of most probable fail probable causes is shown (max four messages) PERFTEST MEMT NACK: NACK CAUSES: MOTS_NOT_LOCKED The selected object is not in LOCKED administrative state. OTHER_TESTS_RUNNING Other incompatible tests are already running or no more parallel execution of tests are possible. A30808-X3247-L230-3-7619 563 Commands Base Station Controller CML:BSC Example of Command Execution Perftest MEMT:NAME=MEMT:0; STOPTEST MEMT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE MEMT STOPTEST MEMT Applicability: Phase 2. Visibility level 2. Command Description: This command allows to terminate the test previously requested; the test can be in progress or in the waiting list (queued). In the first case the process that execute the diagnostic will be interrupted by executing the end phase; in the second case the test will be removed from the waiting list. The validity range of the object address "memtn" can be found in Appendix A. System Responses: STOPTEST MEMT: NAME=MEMT:memtn; STOPTEST MEMT ACK: STOPTEST MEMT:NAME=MEMT:0; testObject=TEST:<n> Result TEST: name = TEST:<n> testOutcome = inconclusive mOts = MEMT:0 testTermination = Cancel executedPhases phaseId = It represents the list of the executed test phases; the list is not shown for test in the waiting list (queued). .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases;the list is not shown for test in the waiting list (queued). phaseId = .... STOPTEST MEMT NACK: NACK CAUSES: 564 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Stoptest MEMT:NAME=MEMT:0; SWITCH MEMT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE MEMT SWITCH MEMT Applicability: Phase 2. Visibility level 1. Command Description: This command allows the standby status exchange of the duplicated objects from "Providing Service" to "Hot Standby" and viceversa. The validity range of the object address "memtn" can be found in Appendix A. System Responses: Application Guidelines: The selected object must be equipped and in "enabled-providing service" state and its duplicated copy must be in "enable-cold/hot standby" state. Example of Command Execution Switch MEMT:NAME=MEMT:0; NO_SUCH_TEST The test is not active. UNABLE_TO_STOP_TEST The test can not be stopped. SWITCH MEMT: NAME=MEMT:memtn; SWITCH MEMT ACK: SWITCH MEMT NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE OTHER_COPY_INVALID_STATE UNSUCCESSFUL_COMMAND_REJECTED A30808-X3247-L230-3-7619 565 Commands Base Station Controller CML:BSC UNLOCK MEMT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE MEMT UNLOCK MEMT Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "memtn" can be found in Appendix A. System Responses: Application Guidelines: It is possible to unlock the MEMT card with the status in LOCKED and UNDER TEST. Example of Command Execution Unlock MEMT:NAME=MEMT:0; UNLOCK MEMT: NAME=MEMT:memtn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. 566 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller MPCC The MPCC is the administrative processor of the SBS system; it is based on a 16 MHz 80C386 SX microprocessor. It is a redundant unit in the active/standby mode. GET MPCC STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE MPCC GET MPCC STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the MPCC object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Standby Status (STNDBY) Unknown Status (UNK). This command allows to display the administrative, operational, usage state and all the status attributes of a specified object. The validity range of the object address "mpccn" can be found in Appendix A. System Responses: Application Guidelines: Only sets with raised bits are shown. Example of Command Execution Get MPCC STAT:NAME=MPCC:0; GET MPCC STAT: NAME=MPCC:mpccn; GET MPCC STAT ACK: GET MPCC STAT NACK: NACK CAUSES: A30808-X3247-L230-3-7619 567 Commands Base Station Controller CML:BSC GETINFO MPCC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE MPCC GETINFO MPCC Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The RSU running object and the RSU version. 2. For each MPCC card: the rmware version the states and statuses: AST, OST, STNDBYST, PRS. 3. The board version: old or new. 4. The active processor operational data (Peak Detection, Mobile Average and Variance for several type of processor data). 5. The operational data of the active processor: real time, current OS time, OS time of last Task init, type and OS time of the last exception, number of task init from last full, number of full init from last bring-up, the exception number from last task, full and bring-up init. 6. For all dynamic memory pool type: the used and total buffer numbers. 7. Total and largest block available. The validity range of the object address mpccn can be found in Appendix A. System Responses: GETINFO MPCC ACK: BSC_CONTROLLER -> LMT_LOCAL 02:30:41 02/01/1992 *** INFORMATION *** GETINFO REPORT: NAME = MPCC:0 RSU RUNNING: RSUEXE 0-1 RSU VERSION: 02-06-01-01-00-00_00-01-10 MPCC 0: FIRMWARE VERSION: SFM1101 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED STANDBY STATUS: PROVIDING_SERVICE GETINFO MPCC: NAME=MPCC:mpccn; 568 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PROCEDURAL STATUS: NONE MPCC 1: FIRMWARE VERSION: SFM1101 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED STANDBY STATUS: HOT_STANDBY PROCEDURAL STATUS: NONE PROCESSOR TYPE: OLD_BOARD_VERSION ACTIVE PROCESSOR OPERATIONAL DATA: HIGH SPEED LINK PEAK DETECTION (N/TU) LINK A RETRANSMISSION REQUESTS 1111 LINK B RETRANSMISSION REQUESTS 2222 RX FIFO THRESHOLD COUNTER 0 TX FIFO OVERFLOW COUNTER 0 VALID PACKET COUNTER 0 NOT SHARED RAM ACCESS COUNTER 1 SHARED RAM ACCESS COUNTER 3 SHARED RAM WRITING ACCESS COUNTER 3 HIGH SPEED LINK MOBILE AVERAGE VARIANCE LINK A RETRANSMISSION REQUESTS 1111 1111 LINK B RETRANSMISSION REQUESTS 2222 2222 RX FIFO THRESHOLD COUNTER 3232 65100 TX FIFO OVERFLOW COUNTER 3232 23000 VALID PACKET COUNTER 3232 23000 NOT SHARED RAM ACCESS COUNTER 3232 23000 SHARED RAM ACCESS COUNTER 3232 23000 SHARED RAM WRITING ACCESS COUNTER 3232 23000 REAL TIME LOAD: 31% CURRENT OS TIME: 0049:05:54 OS TIME OF LAST TASK INIT: 0000:00:00 OS TIME OF LAST EXCEPTION: 0000:00:00 TYPE OF LAST EXCEPTION: 244 NUMBER OF TASK INIT SINCE LAST FULL INIT: 0001 A30808-X3247-L230-3-7619 569 Commands Base Station Controller CML:BSC NUMBER OF FULL INIT SINCE LAST BRING-UP: 0001 NUMBER OF EXCEPTION SINCE LAST TASK INIT: 0000 NUMBER OF EXCEPTION SINCE LAST FULL INIT: 0000 NUMBER OF EXCEPTION SINCE LAST BRING-UP INIT: 0000 DYNAMIC MEMORY USAGE: 0: 0017/0050 1: 0057/0100 2: 0019/0064 3: 0012/0030 4: 0017/0031 5: 0000/0001 6: 0000/0001 7: 0001/0068 8: 0002/0200 9: 0000/0070 A: 0000/0014 TOTAL AND LARGEST BLOCK AVAILABLE: 00000001/00022344 END OF REPORT GETINFO MPCC NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack MPCC: name = MPCC:0 nackCause = <nack cause> Application Guidelines: The attribute TYPE OF LAST EXCEPTION is reserved for the developer. Example of Command Execution Getinfo MPCC:NAME=MPCC:0; GETRELATIONSHIP MPCC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE MPCC GETRELATIONSHIP MPCC NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. GETRELATIONSHIP MPCC: NAME=MPCC:mpccn,ATTID=; 570 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected HMO (Hardware Managed Object); the relationship information consist of all the FMOs (Functional Managed Object) using the HMO service. This information is included in the RELATED_FUNCTIONAL_OBJECTS attribute (ATTID parameter) and the attribute value depends on the working state of the target HMO. For the MPCC object the MEL is the related FMO. The validity range of the object address "mpccn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship MPCC:NAME=MPCC:0,ATTID=RELATED_FUNCTIONAL_OBJECTS; GETSUBO MPCC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE MPCC GETSUBO MPCC Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "mpccn" can be found in Appendix A. GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected HMO the list of related FMOs is displayed (HMO to FMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. GETSUBO MPCC: NAME=MPCC:mpccn; A30808-X3247-L230-3-7619 571 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Getsubo MPCC:NAME=MPCC:0; GETTEST MPCC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE MPCC GETTEST MPCC Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the values of all the attributes belonging to a specified test object; the test object is created by the systemas a result of a request to start a test and it is deleted when the test terminates. The validity range of the object address "mpccn" can be found in Appendix A. System Responses: GETSUBO MPPC ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end there a message is displayed noti- fying the end of the subordinate list. GETSUBO MPCC NACK: NACK CAUSES: None. GETTEST MPCC: NAME=MPCC:mpccn; GETTEST MPCC ACK: GETTEST MPCC:NAME=MPCC:0; name = TEST:<n> mOts = MPCC:0 testState = It can assume one of the following values: not_initialized, idle, initializing, suspended, testing, terminating and disabled. testOutcome = It represents the test result: it can be Inconclusive (meaning-less: that is if the phases already executed were successful) or Fail (if at least one of the executed phases failed). testMonitor 572 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Gettest MPCC:NAME=MPCC:0; LOCK MPCC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE MPCC LOCK MPCC Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The command can be rejected due to high criticity of the system state. The validity range of the object address "mpccn" can be found in Appendix A. System Responses: phaseId = It is a list of the phases to execute and their status that can be: pass, fail, running or waiting. phaseStatus = phaseId = phaseStatus = .... GETTEST MPCC NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. LOCK MPCC: NAME=MPCC:mpccn; LOCK MPCC ACK: LOCK MPCC NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. CRITICAL_ALARM_REJECTED The command has bee rejected due to high criticity of the system state. A30808-X3247-L230-3-7619 573 Commands Base Station Controller CML:BSC Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock MPCC:NAME=MPCC:0; PERFTEST MPCC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE MPCC PERFTEST MPCC Applicability: Phase 2. Visibility level 2. Command Description: This command is used to perform a test on the selected MPCC object; the test consists of the following phases: Accessibilty Test (start phase), ESSC2 & Alarm Test (WP1), FW Card & Hot Link Test (WP2), MPCC FW Update (WP3), End Test (end phase). The validity range of the object address "mpccn" can be found in Appendix A. System Responses: PERFTEST MPCC: NAME=MPCC:mpccn; PERFTEST MPCC ACK: PERFTEST MPCC:NAME=MPCC:0; testObject=TEST:<n> The test results will be displayed at the end of the test phases. Result TEST: name = TEST:<n> testOutcome = This field represents the test result; one of the following values can be displayed: Pass all the test phases are successfully performed. Inconclusive the test is aborted by the system or the test is terminated by the operator. 574 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked" state, if the diagnostic is intrusive. 2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for test" state. When the test result is: "fail" the object goes in Disabled / Failed operational state; "pass" the object goes in Enabled operational state; "inconclusive" the object returns to the operational state previous to the test or in Enabled operational state. Example of Command Execution Perftest MPCC:NAME=MPCC:0; Fail if at least one of the executed phases fail. mOts = It is the identifier of the hardware object under test. testTermination = It specifies how the test is terminated, it can assume the following values: Normal all the test phases are performed. Abort the test is aborted by system. Cancel the test is terminated by operator. executedPhases phaseId = It represents the list of the executed test phases (in case of successful test result, all the test phases will be listed). additionalWords = .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases; they are displayed only for test stopped during it execution. phaseId = .... poprosedRepair Action = A list of most probable fail probable causes is shown (max four messages) PERFTEST MPCC NACK: NACK CAUSES: MOTS_NOT_LOCKED The selected object is not in LOCKED administrative state. OTHER_TESTS_RUNNING Other incompatible tests are already running or no more parallel execution of tests possible. A30808-X3247-L230-3-7619 575 Commands Base Station Controller CML:BSC STOPTEST MPCC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE MPCCSTOPTEST MPCC Applicability: Phase 2. Visibility level 2. Command Description: This command allows to terminate the test previously requested; the test can be in progress or in the waiting list (queued). In the first case the process that execute the diagnostic will be interrupted by executing the end phase; in the second case the test will be removed from the waiting list. The validity range of the object address "mpccn" can be found in Appendix A. System Responses: STOPTEST MPCC: NAME=MPCC:mpccn; STOPTEST MPCC ACK: STOPTEST MPCC:NAME=MPCC:0; testObject=TEST:<n> Result TEST: name = TEST:<n> testOutcome = inconclusive mOts = MPCC:0 testTermination = Cancel executedPhases phaseId = It represents the list of the executed test phases; the list is not shown for test in the waiting list (queued). .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases;the list is not shown for test in the waiting list (queued). phaseId = .... STOPTEST MPCC NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNABLE_TO_STOP_TEST The test can not be stopped. 576 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Stoptest MPCC:NAME=MPCC:0; SWITCH MPCC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE MPCC SWITCH MPCC Applicability: Phase 2. Visibility level 1. Command Description: This command allows the standby status exchange of the duplicated objects from "Providing Service" to "Hot Standby" and viceversa. The validity range of the object address "mpccn" can be found in Appendix A. System Responses: Application Guidelines: 1. The selected object must be equipped and in "enabled-providing service" state and its duplicated copy must be in "enable-cold/hot standby" state. 2. The CMISE, FTAM and CBCL services are located on the MPCC processor; so, as a consequence of an MPCC switch, all the established CMISE, FTAM and CBCL connections are lost. At the end of the switch procedure, these services will be avail- able again on the new running MPCC copy. Example of Command Execution Switch MPCC:NAME=MPCC:0; SWITCH MPCC: NAME=MPCC:mpccn; SWITCH MPCC ACK: SWITCH MPCC NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE OTHER_COPY_INVALID_STATE UNSUCCESSFUL_COMMAND_REJECTED A30808-X3247-L230-3-7619 577 Commands Base Station Controller CML:BSC UNLOCK MPCC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE MPCC UNLOCK MPCC Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "mpccn" can be found in Appendix A. System Responses: Application Guidelines: It is possible to unlock the MPCC card with the status in LOCKED and UNDER TEST. Example of Command Execution Unlock MPCC:NAME=MPCC:0; UNLOCK MPCC: NAME=MPCC:mpccn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. 578 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller A30808-X3247-L230-3-7619 579 Commands Base Station Controller CML:BSC NEYESUSW The NEYESUSW instances identify BTSE or TRAUE software loads present on BSC disk which can be loaded on BTSE/TRAUE network entities. All related commands consist of two fields but only one can be used (NAME or USER LABEL SWLH). GET NEYESUSW Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT NEYESUSW GET NEYESUSW Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of the different attributes of BTS and/or TRAU software loads. The validity range of the object address neyesuswn can be found in Appendix A. System Responses: GET NEYESUSW IDNEYESUSW= [,REQATTL=ULAB, VER, NTWEL, RELRSU]; GET ACK: ULAB: userLabel VER: version NTWEL: networkElement RELRSU: relatedRSU GET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another in progress. OBJECT_NOT_FOUND The referenced object does not exist. ABORT_BY_SYSTEM_NCK An internal system abort has occurred. 580 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get NEYESUSW:NAME=NEYESUSW:0, REQATTL=ULAB&VER&NTWEL&RELRSU; Get NEYESUSW:IDNEYESUSW="userLabel"-BTSE, REQATTL=ULAB&VER&NTWEL&RELRSU; GET NEYESUSW BASICS Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT NEYESUSW GET NEYESUSW BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve all the attributes of NEYESUSW object. The validity range of the object address neyesuswn can be found in Appendix A. System Responses: GET NEYESUSW BASICS: IDNEYESUSW=; GET ACK: ULAB: userLabel VER: version NTWEL: networkElement RELRSU: relatedRSU GET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another in progress. OBJECT_NOT_FOUND The referenced object does not exist. ABORT_BY_SYSTEM_NCK An internal system abort has occurred. A30808-X3247-L230-3-7619 581 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get NEYESUSW BASICS:NAME=NEYESUSW:0; Get NEYESUSW BASICS:IDNEYESUSW="userLabel"-BTSE; GET NEYESUSW STAT Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT NEYESUSW GET NEYESUSW STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the NEYESUSW object: Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address neyesuswn can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get NEYESUSW STAT:NAME=NEYESUSW:0; Get NEYESUSW STAT:IDNEYESUSW="userLabel"-BTSE; GET NEYESUSW STAT IDNEYESUSW=; GET NEYESUSW STAT ACK: Refer to command description. GET NEYESUSW NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_SM_TOO_BUSY The message occurs when the Status Handler task is performing the maximum number of commands. 582 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETINFO NEYESUSW Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT NEYESUSW GETINFO NEYESUSW Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. For the related SW load header le: Instance identier, Network element type, User label associated, Version number, Related les, Operational state; 2. For each executable le present in the SW load header: Instance identier, Processor type, Version number, Related les, Operational state; 3. List of Network Elements for which the NEYESUSW instance is backupESU. The validity range of the object address neyesuswn can be found in Appendix A. System Responses: GETINFO NEYESUSW ACK: ... ... SBS RSUSWLH INSTANCE: RSUSWLH 11 NEY TYPE: BTSE USERLABEL: 262LoadBTS1hs011424 VERSION: 01-01-14-00-24-00_02-04-25 RELATEDFILES: HS011424.SWL SBSOPERATIONALSTATE: ENABLED SBS RSUEXE INSTANCE: RSUEXE 0 GETINFO NEYESUSW IDNEYESUSW=; i If the LMT is connected in remote mode, it is not possible to execute this command. A30808-X3247-L230-3-7619 583 Commands Base Station Controller CML:BSC SBSPROCTYPE: VAMBTSE VERSION: 01-01-14-00-24-00_02-04-25 RELATEDFILES: VS011424.VAM SBSOPERATIONALSTATE: ENABLED SBS RSUEXE INSTANCE: RSUEXE 1 SBSPROCTYPE: TRXA VERSION: 01-01-13-00-03-00_00-11-22 RELATEDFILES: BTSARCO1.SWI SBSOPERATIONALSTATE: ENABLED ... ... SBS RSUEXE INSTANCE: RSUEXE 10 SBSPROCTYPE: LI VERSION: 01-04-13-00-05-00_01-09-27 RELATEDFILES: BTSLICO4.SWI SBSOPERATIONALSTATE: ENABLED LIST OF NE: NE_NUMBER_075 NE_NUMBER_152 END OF REPORT Application Guidelines: The attribute relatedFiles displays only the file name without the complete BSC disk storage path. Example of Command Execution Getinfo NEYESUSW:NAME=NEYESUSW:0; Getinfo NEYESUSW:IDNEYESUSW="userLabel"-BTSE; NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. 584 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller NEDOWNLOAD NEYESUSW Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT NEYESUSW NEDOWNLOAD NEYESUSW Applicability: Phase 2. Visibility level 2. Command Description: This command performs Network Element download from BSC disk to BTSM or TRAU EPROMs. System Responses: NEDOWNLOAD NEYESUSW NTWEL=, NELIST=, ULAB=, MODE=; NEDOWNLOAD ACK: NEDOWNLOAD NACK: NACK CAUSES: RELATED_OBJECTS_DISABLED The NEYESUSW is in DISABLED state. CRC_FAILED The CRC control on the files to be downloaded fails. SW_LOAD_HEADER_NOT_FOUND_NCK The SWLH file is not present. INCONSISTENT_STATE_NCK The NEs are in an inconsistent status. INCONSISTENT_DISK_STATE_NCK One or more disk files are not found. PROCESSING_ERROR_NCK A function call (for example allocation of memory) fails. DOWNLOAD_ALREADY_IN_PROGRESS_NCK A download of the same NE is already in progress. INVALID_PARAMETER_NCK The input parameter is not valid. OBJECT_ALREADY_IN_USE The command clashes with another one already in pregress. OBKECT_ NOT_FOUND The object involved in thos command doesnt exist. NO_TASK_AVAILABLE The Network Element download timeout is expired. No free servers to perform the command. NO_ADMITTED_OPERATION A30808-X3247-L230-3-7619 585 Commands Base Station Controller CML:BSC Application Guidelines: 1. This command is performed if Operational State attribute of NEYESUSW is ENABLED. 2. If the command is given with the parameter MODE set at FORCED, the download is always performed; otherwise (option UNFORCEDset) the download is performed or not if a software load not running, on that Network Element, is absent or not. Example of Command Execution Nedownload NEYESUSW:NTWEL=BTSE,NELIST=NE_NUMBER_000 | NE_NUMBER_001,ULAB="useLabel",MODE=FORCED; NEDOWNLOADABO NEYESUSW Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT NEYESUSW NEDOWNLOADABO NEYESUSW Applicability: Phase 2. Visibility level 2. Command Description: This command performs Network Element abort download from BSC disk to BTSM or TRAU EPROMs. The validity range of the object address neyesuswn can be found in Appendix A. System Responses: Waiting for SDSM server activation ABORT_BY_SYSTEM_NCK The command is rejected due to an internal subsystemn abort. NEDOWNLOADABO NEYESUSW NAME=NEYESUSW:neyesuswn; NEDOWNLOADABO ACK: NEDOWNLOADABO NACK: NACK CAUSES: INVALID_PARAMETER_NCK No NE download in progress to abort. NO_ADMITTED_OPERATION Waiting for SDSM server activation. NE download operation can not be aborted. NO_TASKS_AVAILABLE NE download timeout is expired. 586 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: This command is performed if a Network Element download procedure is in progress. Example of Command Execution Nedownloadabo NEYESUSW:NAME=NEYESUSW:0; A30808-X3247-L230-3-7619 587 Commands Base Station Controller CML:BSC NSVC The NSVC (Network Service Virtual Container) functional object represents the end-to-end communication between BSS and SGSN. At each side of Gb interface there is one to one correspondence between NSVC and NSVL, then the NSVL can be seen as an attribute of NSVC. CREATE NSVC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL NSVC CREATE NSVC Applicability: Phase 2. Visibility level 2. Command Description: This command creates an instance of the NSVC object class. It can be done only if FRL is created. The status at creation will be Locked Disabled/Offline. When the GbIC have been aligned with the remote peer the NSVC object will be put in Enabled state. The validity range of the object address "nsvcn" can be found in Appendix A. System Responses: Application Guidelines: None. CREATE NSVC: NAME=NSVC:nsvcn,NSVCI=,NSVLI=; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The FRL object instance must be already equipped. UNSUCCESSFUL_EXCEED_OBJECT_NBR NSVC instances greater than 31 or more than 16 NSVCs for PCU are allowed only if the network card is NTWSNAP or NTWSNAP_STLP. INVALID_ATTRIBUTE_VALUE Different NSVCs of the same PCU/PCUTD cannot have the same NSVCI or the same NSVLI. 588 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Create NSVC:NAME=NSVC:10,NSVCI=3,NSVLI=20-50; DELETE NSVC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL NSVC DELETE NSVC Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a previously created instance of the NSVC object class. It can be done only if the NSVC is in locked state. The validity range of the object address "nsvcn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete NSVC:NAME=NSVC:10; DELETE NSVC: NAME=NSVC:nsvcn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a NSVC, the relative object instance must be in LOCKED state. UNSUCCESSFUL_SUBORDINATE_EQUIPPED The last NSVC can be deleted only if there are no PTPPKFs equipped. A30808-X3247-L230-3-7619 589 Commands Base Station Controller CML:BSC GET NSVC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL NSVC GET NSVC Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameter values of an instance of the NSVC object class. The validity range of the object address "nsvcn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get NSVC:NAME=NSVC:0,REQATTL=NSVCI&NSVLI; GET NSVC BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL NSVC GET NSVC BASICS Applicability: Phase 2. Visibility level 1. GET NSVC: NAME=NSVC:nsvcn [,REQATTL=NSVCI, NSVLI]; GET ACK: NAME: name NSVCI: Network Service Virtual Connection Identifier NSVLI: Network Service Virtual Link Identifier GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET NSVC BASICS: NAME=NSVC:nsvcn; 590 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "nsvcn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get NSVC BASICS:NAME=NSVC:0; GET NSVC STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL NSVC GET NSVC STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the NSVC object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "nsvcn" can be found in Appendix A. System Responses: GET ACK: NAME: name NSVCI: Network Service Virtual Connection Identifier NSVLI: Network Service Virtual Link Identifier GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET NSVC STAT: NAME=NSVC:nsvcn; GET NSVC STAT ACK: GET NSVC STAT NACK: A30808-X3247-L230-3-7619 591 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get NSVC STAT:NAME=NSVC:0; GETINFO NSVC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL NSVC GETINFO NSVC Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The states and statuses of the NSVC: AST, OST, AVS, CST, PRS. 2. The PCU or PCUTD number. 3. Six samples for each type of the following counters for the last 5 minutes: syntactic counter semantic counter error event counter non-error event counter other error event counter congestion counter. 4. The list of max 400 PTPPKFs connected. The validity range of the object address nsvcn can be found in Appendix A. System Responses: GETINFO NSVC ACK: BSC_CONTROLLER -> LMT_LOCAL 11:41:14 22/03/1999 *** INFORMATION *** GETINFO REPORT: NAME = NSVC:0 ADMINISTRATIVE STATE: UNLOCKED NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETINFO NSVC: NAME=NSVC:nsvcn; 592 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE PROCEDURAL STATUS: NONE PCU <or PCUTD> NBR: 2 SYNTACTIC LAST 5 MIN (6 SAMPLES): 2 9 SEMANTIC LAST 5 MIN (6 SAMPLES): 1 ERROR EVENT LAST 5 MIN (6 SAMPLES): 30 45 NON ERROR EVENT LAST 5 MIN (6 SAMPLES): 2 5 10 OTHER ERROR EVENT LAST 5 MIN (6 SAMPLES): 10 CONGESTION LAST 5 MIN (6 SAMPLES): 1 ATTESTED BVCI LIST (MAX 400): 2 15 ... END OF REPORT GETINFO NSVC NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack NSVC: name = NSVC:0 nackCause = <nack cause> Application Guidelines: None. Example of Command Execution Getinfo NSVC:NAME=NSVC:0; NACK CAUSES: UNSUCCESSFUL_OBJECT_NOT_EQUIPPED The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. A30808-X3247-L230-3-7619 593 Commands Base Station Controller CML:BSC GETRELATIONSHIP NSVC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL NSVC GETRELATIONSHIP NSVC Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of all the HMOs (Hardware Managed Object) supporting the FMO functionality. For the NSVC object the related HMOs are the following: LICD/LICDS, EPWR, PPCU, PWRD, MPCC, TDPC, MEMT, NTW, PPXU and if the FRL object is connected via A interfce BSMS and TPWR objects. The validity range of the object address "nsvcn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship NSVC:NAME=NSVC:0; GETSUBO NSVC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL NSVC GETSUBO NSVC GETRELATIONSHIP NSVC: NAME=NSVC:nsvcn; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. GETSUBO NSVC: NAME=NSVC:nsvcn; 594 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "nsvcn" can be found in Appendix A. System Responses Application Guidelines: None. Example of Command Execution Getsubo NSVC:NAME=NSVC:0; LOCK NSVC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL NSVC LOCK NSVC Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". Locking the last NSVC means services interruptions for all PTPPKF attached to the PCU. The command can cuase services interruption. The validity range of the object address "nsvcn" can be found in Appendix A. System Responses: GETSUBO ACK: The output of the command can be composed by one or more pack with a maximumnumber of three subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GETSUBO NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK NSVC: NAME=NSVC:nsvcn; LOCK NSVC ACK: LOCK NSVC NACK: NACK CAUSES: A30808-X3247-L230-3-7619 595 Commands Base Station Controller CML:BSC Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). 3. If the NSVC to be locked is the last available NSVC within the PCU the command is rejected. Example of Command Execution Lock NSVC:NAME=NSVC:0; UNLOCK NSVC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL NSVC UNLOCK NSVC Applicability: Phase 2. Visibility level 1. Command Description: This command removes the operator block and the unit remains in the operational state as it is at the moment of the command. The validity range of the object address "nsvcn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock NSVC:NAME=NSVC:0; UNSUCCESSFUL_INVALID_STATUS ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNLOCK NSVC: NAME=NSVC:nsvcn; UNLOCK ACK: Successful UNLOCK NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_STATUS 596 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller NTW The NTW object represents the switching network of the BSC; it is a redundant unit in the active/standby mode and it is controlled by the MPCC. FORCSYNC NTW Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCENTW FORCSYNC NTW Applicability: Phase 2. Visibility level 2. Command Description: This command allows to force the free-running state of the active PLLH, based on the tune word stored into the internal semi-permanent memory (EEPROM) of the card or based on the DAC (Digit to Analog Converter) output word. The validity range of the object address "ntwn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Forcsync NTW:NAME=NTW:0,WRTYP=Tune; FORCSYNC NTW: NAME=NTW:ntwn, WRTYP=; FORCSYNC ACK: Successful FORCSYNC NACK: NACK CAUSES: UNSUCCESSFUL_NTW_OUTAGE Both copies of network are out of service. UNSUCCESSFUL_WRONG_COPY The command has been sent to standby copy instead of the active one. UNSUCCESSFUL_HW_FAILURE Hardware problems during the execution of command. A30808-X3247-L230-3-7619 597 Commands Base Station Controller CML:BSC GET NTW STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE NTWGET NTW STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the NTW object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Standby Status (STNDBY) Unknown Status (UNK). The validity range of the object address "ntwn" can be found in Appendix A. System Responses: Application Guidelines: Only sets with raised bits are shown. Example of Command Execution Get NTW STAT:NAME=NTW:0; GETRELATIONSHIP NTW Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE NTW GETRELATIONSHIP NTW GET NTW STAT: NAME=NTW:ntwn; GET NTW STAT ACK: GET NTW STAT NACK: NACK CAUSES: GETRELATIONSHIP NTW: NAME=NTW:ntwn,ATTID=; 598 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected HMO (Hardware Managed Object); the relationship information consist of all the FMOs (Functional Managed Object) using the HMO service. This information is included in the RELATED_FUNCTIONAL_OBJECTS attribute (ATTID parameter) and the attribute value depends on the working state of the target HMO. For the NTW object the MEL is the related FMO. The validity range of the object address "ntwn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship NTW:NAME=NTW:0,ATTID=RELATED_FUNCTIONAL_OBJECTS; GETSUBO NTW Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCENTW GETSUBO NTW Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "ntwn" can be found in Appendix A. GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected HMO the list of related FMOs is displayed (HMO to FMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. GETSUBO NTW: NAME=NTW:ntwn; A30808-X3247-L230-3-7619 599 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Getsubo NTW:NAME=NTW:0; GETSYNC NTW Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE NTWGETSYNC NTW Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the currently used synchronization source, the current value of the DAC(Digit to Analog Converter) output word into memory and the tune word into the semi-permanent location. This can give the way to evaluate the quality of the tune word with respect to the currently frequency generated by the system. The validity range of the object address "ntwn" can be found in Appendix A. System Responses: GETSUBO NTW ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end there a message is displayed noti- fying the end of the subordinate list. GETSUBO NTW NACK: NACK CAUSES: None. GETSYNC NTW: NAME=NTW:ntwn; GETSYNC ACK: Successful VERSION This attribute identifies the Hw and Fw version. Validity range: version 20 ASCII characters string; SYNCOPMO This attribute defines the Sync Operation Mode. Validity range: syncOpMode SYNC ASYNC_ON_TUNE ASYNC_ON_DAC SLAVE 600 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Getsync NTW:NAME=NTW:0 GETTEST NTW Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE NTW GETTEST NTW Applicability: Phase 2. Visibility level 2. NAME1 Selected Source SRCFREQ Source Frequency(#KHz) Validity range: sourceFrequency 0-4294967295 ELATIME The Elapsed Time is shown in days, hours, minutes and seconds. Validity range: elapsedTime 0-4294967295 TUNEWR Tune Value. Validity range: tuneWord 0-65535 DACWR DAC value. Validity range: dacWord 0-65535 DELTA Delta PHER PhaseError GETSYNC NACK: NACK CAUSES: UNSUCCESSFUL_NTW_OUTAGE Both copies of network are out of service. UNSUCCESSFUL_HW_FAILURE Hardware problems during the execution of the command. UNSUCCESSFUL_FAILED The NTWcopy which the command has been addressed to is disabled. GETTEST NTW: NAME=NTW:ntwn; A30808-X3247-L230-3-7619 601 Commands Base Station Controller CML:BSC Command Description: This command is used to retrieve the values of all the attributes belonging to a specified test object; the test object is created by the systemas a result of a request to start a test and it is deleted when the test terminates. The validity range of the object address "ntwn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Gettest NTW:NAME=NTW:0; LOCK NTW Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE NTWLOCK NTW Applicability: Phase 2. GETTEST NTW ACK: GETTEST NTW:NAME=NTW:0; name = TEST:<n> mOts = NTW:0 testState = It can assume one of the following values: not_initialized, idle, initializing, suspended, testing, terminating and disabled. testOutcome = It represents the test result: it can be Inconclusive (meaning-less: that is if the phases already executed were successful) or Fail (if at least one of the executed phases failed). testMonitor phaseId = It is a list of the phases to execute and their status that can be: pass, fail, running or waiting. phaseStatus = phaseId = phaseStatus = .... GETTEST NTW NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. LOCK NTW: NAME=NTW:ntwn; 602 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "ntwn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed, no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). 3. It is emitted when the PLLH has become synchronized to an external source little time ago, and the switch of the master PLLH (for LOCK or SWITCH command) would leave the frequency of the new active PLLH with a bad value; it can be answered up to 5 minutes after a SYNC or SYNE has gone PROVIDING SERVICE. The same can happen if less than 5 minutes have passed since last switch of NTW. 4. The LOCK of both NTWobjects leads to an interruption of the whole BSS call trafc. The LOCK command for the second board is not refused and there is no system warning generation. Example of Command Execution Lock NTW:NAME=NTW:0; PERFTEST NTW Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE NTW PERFTEST NTW Applicability: Phase 2. Visibility level 2. Command Description: This command is used to perform a test on the selected NTW object; the test consists of the following phases: Accessibility Test (start phase), LOCK NTW ACK: LOCK NTW NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. PERFTEST NTW: NAME=NTW:ntwn; A30808-X3247-L230-3-7619 603 Commands Base Station Controller CML:BSC UBEX Force Alarm Test (WP1), PLLH Force Alarm Test (WP2), PLLH FW Self Test (WP3), SN Force Alarm Test (WP4), SN16 Speech RAM Adderess Parity Test (WP5), SN16 Speech RAM Data Parity Test (WP6), SN16 Control RAM Adderess Parity Test (WP7), End Test (end phase). The validity range of the object address "ntwn" can be found in Appendix A. System Responses: PERFTEST NTW ACK: PERFTEST NTW:NAME=NTW:0; testObject=TEST:<n> The test results will be displayed at the end of the test phases. Result TEST: name = TEST:<n> testOutcome = This field represents the test result; one of the following values can be displayed: Pass all the test phases are successfully performed. Inconclusive the test is aborted by the system or the test is terminated by the operator. Fail if at least one of the executed phases fail. mOts = It is the identifier of the hardware object under test. testTermination = It specifies how the test is terminated, it can assume the following values: Normal all the test phases are performed. Abort the test is aborted by system. Cancel the test is terminated by operator. executedPhases phaseId = It represents the list of the executed test phases (in case of successful test result, all the test phases will be listed).. additionalWords = .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases; they are displayed only for test stopped during it execution. phaseId = .... poprosedRepair Action = A list of most probable fail probable causes is shown (max four messages) PERFTEST NTW NACK: 604 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked" state, if the diagnostic is intrusive. 2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for test" state. When the test result is: "fail" the object goes in Disabled / Failed operational state; "pass" the object goes in Enabled operational state; "inconclusive" the object returns to the operational state previous to the test or in Enabled operational state. Example of Command Execution Perftest NTW:NAME=NTW:0; STOPTEST NTW Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE NTW STOPTEST NTW Applicability: Phase 2. Visibility level 2. Command Description: This command allows to terminate the test previously requested; the test can be in progress or in the waiting list (queued). In the first case the process that execute the diagnostic will be interrupted by executing the end phase; in the second case the test will be removed from the waiting list. The validity range of the object address "ntwn" can be found in Appendix A. System Responses: NACK CAUSES: MOTS_NOT_LOCKED The selected object is not in LOCKED administrative state. OTHER_TESTS_RUNNING Other incompatible tests are already running or no more parallel executions of tests are possible. STOPTEST NTW: NAME=NTW:ntwn; STOPTEST NTW ACK: STOPTEST NTW:NAME=NTW:0; testObject=TEST:<n> Result TEST: name = TEST:<n> testOutcome = inconclusive A30808-X3247-L230-3-7619 605 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Stoptest NTW:NAME=NTW:0; SWITCH NTW Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE NTW SWITCH NTW Applicability: Phase 2. Visibility level 1. Command Description: This command allows the standby status exchange of the duplicated objects from "Providing Service" to "Hot Standby" and viceversa. The validity range of the object address "ntwn" can be found in Appendix A. System Responses: mOts = NTW:0 testTermination = Cancel executedPhases phaseId = It represents the list of the executed test phases; the list is not shown for test in the waiting list (queued). .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases;the list is not shown for test in the waiting list (queued). phaseId = .... STOPTEST NTW NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNABLE_TO_STOP_TEST The test can not be stopped. SWITCH NTW: NAME=NTW:ntwn; SWITCH NTW ACK: SWITCH NTW NACK: 606 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The selected object must be in "enabled-providing service" state and its duplicated copy must be in "enable-cold/hot standby" state, otherwise the response message will be ALREADY_IN_TARGET_STATE. 2. The network switch command cannot be performed within 5 minutes from the previous one if a SYNC or SYNE object is congured due to hardware constraints. Example of Command Execution Switch NTW:NAME=NTW:0; UNLOCK NTW Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE NTWUNLOCK NTW Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state "Unlocked". The validity range of the object address "ntwn" can be found in Appendix A. System Responses: Application Guidelines: It is possible to unlock the NTW card with the status in LOCKED and UNDER TEST. NACK CAUSES: ALREADY_IN_TARGET_STATE OTHER_COPY_INVALID_STATE UNSUCCESSFUL_COMMAND_REJECTED STANDBY_PLLH_DAC_WORD_EVOLVING It is emitted when the PLLH has become synchronized to an external source little time ago, and the switch of the master PLLH (for LOCK or SWITCH command) would leave the frequency of the new active PLLH with a bad value; it can be answered up to 5 minutes after a SYNC or SYNE has gone PROVIDING SERVICE. The same can happen if less than 5 minutes have passed since last switch of NTW. UNLOCK NTW: NAME=NTW:ntwn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. A30808-X3247-L230-3-7619 607 Commands Base Station Controller CML:BSC Example of Command Execution Unlock NTW:NAME=NTW:0; UPDATETUNE NTW Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE NTWUPDATETUNE NTW Applicability: Phase 2. Visibility level 2. Command Description: This command allows to calibrate the PLLH. Calibrating PLLH means to copy the actual DAC word into a permanent memory, when the card is synchronized, in order to memorize permanently the frequency of the synchronizing signal (the DACvalue is the numerical value corresponding to the frequency of the oscillator when it will work in holdover mode. When synchronized, the DAC value represents the mean frequency of the synchronizing signal). Calibration is not essential into a synchronized network but it is recommended to execute it regularly, especially in case of a poor synchronized network, i.e. when there is some probability to work in ASYNCHRONOUS mode. Even in case of a synchronous network, the well calibrated PLLH will behave better in the transitory phase from ASYNCHRONOUS to SYNCHRONIZED operating mode reducing the amplitude of the transitory phase error. It is also important to have a PLLH not completely un-calibrated because the UPDATETUNE NTW is used by PLLH FW in the initial phase measurement of the external signals (on which synchronize) and for auto-tests. The validity range of the object address "ntwn" can be found in Appendix A. System Responses: UPDATETUNE NTW: NAME=NTW:ntwn; UPDATETUNE ACK: Successful UPDATETUNE NACK: NACK CAUSES: UNSUCCESSFUL_NTW_OUTAGE Both copies of network are out of service. UNSUCCESSFUL_WRONG_COPY The command has been sent to standby copy instead of the active one. UNSUCCESSFUL_HW_FAILURE Hardware problems during the execution of the command. PLL_LOCK_IN PROGRESS 608 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The command must never be given on a PLLH powered for less than half an hour, in order to avoid to un-calibrate the PLLH card. 2. In order to enter the command the following requirements must be fullled: the PLLHcard to be calibrated has to be powered without interruptions for at least one day, better a week or more; the mean frequency accuracy of the synchronizing signal must be better than 1E-9. If the accuracy of the frequency of the PCM line used to synchronize is unknown, the best thing to do is to synchronize BSC externally using the SYNE inputs connected to a local atomic generator (rubidium or cesium standard) and then calibrate the PLLH; the PLLH card must be synchronized since at least 5 minutes (elapsed time) for PLLH-V1 and jitter/wander free synchronization signal (this condition can be veri- ed if the "phase error" parameter on LMT report is 0), since at least 5/7 hours for ITU-T G823 jitter/wander affected signal for PLLH-V2. Example of Command Execution Updatetune NTW:NAME=NTW:0; A30808-X3247-L230-3-7619 609 Commands Base Station Controller CML:BSC NUC The NUC is a logical object that allows the semi-permanent connection between a channel of Asub interface with a channel of Abis or A interface. CREATE NUC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL NUC CREATE NUC Applicability: Phase 2. Visibility level 2. Command Description: This command sets the specific parameters for NUC object. The validity range of the object address "nucn" can be found in Appendix A. System Responses: CREATE NUC: NAME=NUC:nucn, FRTERM=, TOTERM=; CREATE ACK: Successful CREATE NACK: NACK CAUSES: OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. RELATED_PCMA_NOT_EQUIPPED The PCMA, which the timeslot instance belongs to, must be already equipped. RELATED_PCMB_NOT_EQUIPPED The PCMB, which the timeslot instance belongs to, must be already equipped . RELATED_PCMS_NOT_EQUIPPED The PCMS, which the timeslot instance belongs to, must be already equipped. UNSUCCESSFUL_TIME_SLOT_ALREADY_ALLOCATED The timeslot of the PCMB or the PCMS must be not congured as LPDLS or LPDLM or LPDLR. The timeslot of the PCMB must be available (not already congured as SUBTSLB object or Layer1ControlTS). UNSUCCESSFUL_INVALID_CONNECTION The FromTermination and the ToTermination of a NUC object cannot be on the same type of PCM. 610 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: If the NUC connects a PCMB timeslot with a PCMA timeslot, the timeslot of the PCMS with the same number of the selected PCMA timeslot must not carry a X25A/SS7/NUC link. Example of Command Execution Create NUC:NAME=NUC:3,FRTERM=PCMB:2-1,TOTERM=PCMS:3-20; DELETE NUC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL NUC DELETE NUC Applicability: Phase 2. Visibility level 2. At the creation of a NUC between a PCMS and a PCMA, both the PCM lines must belong to the same TRAU. UNSUCCESSFUL_INVALID_FROM_TERM The From Termination of a NUC object can not be a PCMA line. UNSUCCESSFUL_INVALID_TO_TERM The To Termination of a NUC object cannot be a PCMB line. UNSUCCESSFUL_INVALID_TIME_SLOT If the NUC crosses the TRAU Network element, the timeslots of the PCMS and of the PCMA must have the same number. This is due to hardware constraining on TRAU. The timeslot value is not compatible with the PCM line type (PCMTYPE attribute of BSC object). UNSUCCESSFUL_INVALID_STATUS Before creating a NUCthe relative TRAUobject instance, if any, must be in LOCKED state. UNSUCCESSFUL_X25A_LINK The timeslot of the PCMA/PCMS must not carry a X25A link. Make reference to the Application Guideline. UNSUCCESSFUL_SS7L_LINK The timeslot of the PCMA/PCMS must not carry a SS7 link. Make reference to the Application Guideline. UNSUCCESSFUL_NUC_LINK The timeslot of the PCMA/PCMB/PCMS must not carry a NUC link. Make reference to the Application Guideline. UNSUCCESSFUL_WRONG_ME_ID The rst eld of the From Termination/To Termination attribute is incorrect. For more details about its conguration rules see the attribute description (Chapter 4 of this Manual). DELETE NUC: NAME=NUC:nucn; A30808-X3247-L230-3-7619 611 Commands Base Station Controller CML:BSC Command Description: This command deletes a NUC object instance. The validity range of the object address "nucn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete NUC:NAME=NUC:4; GET NUC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL NUC GET NUC Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameter values of a NUC object instance. The validity range of the object address "nucn" can be found in Appendix A. System Responses: DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a NUC, the relative TRAUobject instance, if any, must be in LOCKED state. GET NUC: NAME=NUC:nucn [,REQATTL= FRTERM, TOTERM]; GET ACK: FRTERM: fromTermination TOTERM: toTermination GET NACK: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 612 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get NUC:NAME=NUC:0,REQATTL=FRTERM&TOTERM; GET NUC BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL NUC GET NUC BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "nucn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get NUC BASICS:NAME=NUC:0; GET NUC STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL NUC GET NUC STAT GET NUC BASICS: NAME=NUC:nucn; GET ACK: FRTERM: fromTermination TOTERM: toTermination GET NACK: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET NUC STAT: NAME=NUC.nucn; A30808-X3247-L230-3-7619 613 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the NUC object: Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "nucn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution: Get NUC STAT:NAME=NUC:5; GETRELATIONSHIP NUC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL NUC GETRELATIONSHIP NUC Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of all the HMOs (Hardware Managed Object) supporting the FMO functionality. For the NUC object the related HMOs are the following: LICD/LICDS, EPWR, BSMS, TPWR, PPLD, PWRD, MPCC, TDPC, MEMT, NTW and PPXL. The validity range of the object address "nucn" can be found in Appendix A. GET NUC STAT ACK: GET NUC STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETRELATIONSHIP NUC: NAME=NUC:nucn; 614 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Getrelationship NUC:NAME=NUC:0; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. A30808-X3247-L230-3-7619 615 Commands Base Station Controller CML:BSC OMAL The OMAL object is the link connecting the BSC, through the IXLT, to the RC or LMT with X.25 protocol. CREATE OMAL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL OMAL CREATE OMAL Applicability: Phase 2. Visibility level 2. Command Description: This command adds the OMAL object that represents the logical link for the communi- cation with the RC. The validity range of the object address "omaln" can be found in Appendix A. System Responses: CREATE OMAL: NAME=OMAL:omaln [,LINKTYPE=] ,[X121ADDR=] [,OMCCPT=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_INVALID_ATTRIBUTES Different copies of OMAL must have different X121ADDR. The X121ADDR attribute must be set to a value different from NULL if LINKTYPE attribute is set to X25A/X25D. The X121ADDR attribute cannot be set to a value different from NULL if LINKTYPE attribute is set to IPLI. The OMCCPT attribute cannot be set to NULL if LINKTYPE attribute is set to X25A/X25D. The OMCCPT attribute cannot be set to a value different from NULL if LINKTYPE attribute is set to IPLI. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The X25A/X25D object instance must be already equipped. The IPLI object must be already equipped if the operator sets LINK- TYPE attribute to the value IPLI. UNSUCCESSFUL_COPY_ZERO_NOTEQUIPPED 616 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: The X121ADDR must be a numeric string. Example of Command Execution Create OMAL:NAME=OMAL:0,LINKTYPE=X25D, X121ADDR="123451234512345123451234512345123",OMCCPT=<DEFAULT>; DELETE OMAL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL OMAL DELETE OMAL Applicability: Phase 2. Visibility level 2. Command Description: This command deletes the OMAL object. The validity range of the object address "omaln" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution DELETE OMAL:NAME=OMAL:0; The creation of copy #1 is subordinated to the presence of copy #0. UNSUCCESSFUL_VAR_OUT_OF_RANGE Only one OMAL instance (OMAL:0) can be equipped if the LINK- TYPE attribute is set to IPLI. DELETE OMAL: NAME=OMAL:omaln; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_COPY_ONE_EQUIPPED The deletion of the instance #0 is possible only if the copy #1 is not present. A30808-X3247-L230-3-7619 617 Commands Base Station Controller CML:BSC GET OMAL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL OMAL GET OMAL Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameters of the OMAL object. The validity range of the object address "omaln" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get OMAL:NAME=OMAL:0,REQATTL=LINKTYPE&X121ADDR&OMCCPT; GET OMAL BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL OMAL GET OMAL BASICS Applicability: Phase 2. Visibility level 1. GET OMAL: NAME=OMAL:omaln [,REQATTL= LINKTYPE, X121ADDR, OMCCPT]; GET ACK: NAME: name LINKTYPE: linkType X121ADDR: x121Addr OMCCPT: omcCapabilityTimer GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. GET OMAL BASICS: NAME=OMAL:omaln; 618 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "omaln" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get OMAL BASICS:NAME=OMAL:0; GET OMAL STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL OMAL GET OMAL STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the OMAL object: Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Standby Status (STNDBY) Unknown Status (UNK). The validity range of the object address "omaln" can be found in Appendix A. System Responses: GET ACK: NAME: name X121ADDR: x121Addr OMCCPT: omcCapabilityTimer GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. GET OMAL STAT: NAME=OMAL:omaln; GET OMAL STAT ACK: A30808-X3247-L230-3-7619 619 Commands Base Station Controller CML:BSC Application Guidelines: 1. The object selected must be created. 2. Only sets with raised bits are shown. 3. Explanation of the meaning of OMAL ,IXLT, CBCL, X25A and X25D status: The handling of the status attributes may be summarized as follows: The operational state handling may be summarized as follows: Example of Command Execution Get OMAL STAT:NAME=OMAL:0; GET OMAL X25INFO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL OMAL GET OMAL X25INFO Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve information about a X25 OMAL link. The validity range of the object address "omaln" can be found in Appendix A. GET OMAL STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED Value OMAL standby PROVIDINGSERVICE not used HOTSTANDBY not used COLDSTANDBY not used NULL_STATUS not used availability FAILED CBCL DISABLED layer 7 is down DEGRADED not used OFF_DUTY not used DEPENDENCY X25A/X25D is DISABLED or LOCKED procedural INITIALIZING not used OMAL ENABLED layer 7 up DISABLED layer 7 down GET OMAL X25INFO: NAME=OMAL:omaln; 620 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None Example of Command Execution Get OMAL X25INFO:NAME=OMAL:0; GETRELATIONSHIP OMAL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL OMAL GETRELATIONSHIP OMAL Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of all the HMOs (Hardware Managed Object) supporting the FMO functionality. For the OMAL object the related HMOs are the following: IXLT, PWRD, MPCC, EPWR and either X25D (for direct OMC/BSC connection) or X25A, LICD/LICDS, TDPC, MEMT, NTW, BSMS and TPWR (for OMC/BSC connection via A interface). The validity range of the object address "omaln" can be found in Appendix A. System Responses: GET OMAL X25INFO ACK: GET OMAL X25INFO NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETRELATIONSHIP OMAL: NAME=OMAL:omaln; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED A30808-X3247-L230-3-7619 621 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Getrelationship OMAL:NAME=OMAL:0; GETSUBO OMAL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL OMAL GETSUBO OMAL Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "omaln" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo OMAL:NAME=OMAL:0; The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. GETSUBO OMAL: NAME=OMAL:omaln; GETSUBO OMAL ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end there a message is displayed noti- fying the end of the subordinate list. GETSUBOOMAL NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 622 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SET OMAL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL OMAL SET OMAL Applicability: Phase 2. Visibility level 2. Command Description: This command set the parameters for the OMAL object. The validity range of the object address "omaln" can be found in Appendix A. System Responses: Application Guidelines: The X121ADDR must be a numeric string. Example of Command Execution Set OMAL:NAME=OMAL:0,X121ADDR=956712345123451234512345123451234, OMCCPT=<DEFAULT>; SET OMAL: NAME=OMAL:omaln [,X121ADDR=] [,OMCCPT=]; SET ACK: Successful SET NACK: NACK CAUSES:: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_INVALID_ATTRIBUTES Different copies of OMAL must have different X121ADDR. The X121ADDR attribute cannot be set to NULL if LINKTYPE attribute is set to X25A/X25D. The X121ADDR attribute cannot be set to a value different from NULL if LINKTYPE attribute is set to IPLI. The OMCCPT attribute cannot be set to NULL if LINKTYPE attribute is set to X25A/X25D. The OMCCPT attribute cannot be set to a value different from NULL if LINKTYPE attribute is set to IPLI. A30808-X3247-L230-3-7619 623 Commands Base Station Controller CML:BSC OPC The OPC object is the originating point in the BSC for common channel signalling n. 7. CREATE OPC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL OPC CREATE OPC Applicability: Phase 2. Visibility level 2. Command Description: This command sets the values of the parameters that are used in the Common Channel Signalling System (SS7). The validity range of the object address "bscn" can be found in Appendix A. System Responses: Application Guidelines: 1. OPC, MSCSPC and SMLCSPC attributes must differ fromeach other in at least one eld. CREATE OPC: NAME=OPC:bscn, SS7MTPTYP=, OPC=, MSCSPC= [,NTWIND=] [,BSSAPSSN=] [,MSCPERTFLAG=] [,TCONN=] [,TIAS=] [,TIAR=] [,TREL=] [,TGUARD=] [,TSBS=] [,TWCUSER=] [,TINT=] [,SMLCSPC=] [,APLESSNBSC=] [,APLESSNSMLC=] [,SMLCPERTFLAG=] [,M2T1=] [,M2T2=] [,M2T3=] [,M2T4N=] [,M2T4E=] [,M2T5=] [,M2T6=] [,M2T7=] [,FLOWCTH=] [,CONGTH=] [,SANTIME=] [,ERRCORMTD=] [,N1=] [,N2=] [,M3T1=] [,M3T2=] [,M3T3=] [,M3T4=] [,M3T5=] [,M3T12=] [,M3T13=] [,M3T14=] [,M3T17=] [,M3T19=] [,M3T22OR20=] [,M3T23OR21=] [,M3T1TM=] [,M3T2TM=] [,M3T10=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_INVALID_ATTRIBUTES Make reference to Application Guidelines n. 1, n. 2, n. 3, n. 7, n. 9. UNSUCCESSFUL_VAR_OUT_OF_RANGE Make reference to Application Guidelines n. 4, n. 5, n. 6, n. 8, n. 15. 624 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 2. In CCITT case the subeld NetworkIdentier of OPC, MSCSPC and SMLCSPC attributes is not congurable, while in ANSI case it is mandatory. 3. If the attribute SS7MTPTYP is set at ANSI, the attributeNetworkCluster cannot assume value 0 if 0<NIDEN<6. 4. Depending on the value of the attribute SS7MTPTYP the subelds of the attributes OPC, MSCSPC and SMLCSPC have different ranges, as shown in the following table: 5. If the attribute SS7MTPTYP is set at ANSI, the attribute NETWINDcan assume only the value NAT0. 6. Depending on the value of the attribute SS7MTPTYP of OPC object the timers (except M2T5 timer) have different ranges, as shown in the following table: The value assigned to M2T6 timer must be lower or equal to the M3T1TM one. 7. The following tables show the possible values for CONGTHRE and FLOWCTH parameters and the related percentage of transmit buffer used which cause the request of load reduction measures or the subsequently discarding of messages. ANSI CCITT Network Cluster Member 1-255 0-255 Network Cluster 0-255 0-63 Network Identifier 1-254 NO_CONFIG Timer Name ANSI Range CCITT Range M2T1 129-160 400-500 M2T2 50-300 50-1500 M2T3 50-140 10-15 M2T4N 15-30 75-95 M2T4E 4-7 4-5 M2T6 10-60 30-60 M2T7 5-20 5-20 CONGTHRE (congestion control threshold) FLOWCTH (flow control threshold) value abatment onset discard value abatment onset 0 = = = 0 = = 1 45 50 not used 1 50 60 2 45 50 55 2 50 65 3 30 35 40 3 50 70 4 35 40 45 4 40 50 5 40 45 50 5 40 55 6 45 50 55 6 40 60 7 45 55 8 45 60 9 45 65 Tab. 2.4 Congestion and Flow Control Thresholds A30808-X3247-L230-3-7619 625 Commands Base Station Controller CML:BSC 8. Depending on the value of the attribute SS7MTPTYP of OPC object, the timers M3T22OR20 an M3T22OR21 have different ranges, as shown in the following table: 9. The value assigned to M3T1TM timer must be greater or equal to the M2T6 one (timer of OPC). 10. If a link interruption shorter than TGUARD timer value occurs, busy CIC's will not be released; i.e. existing speech connections will be saved. After link re-alignment (MTP) no reset message will be sent on the A-interface. If a link interruption longer than TGUARD timer value occurs, the existing speech connections will be released and after link re-alignment a reset message will be sent on theA-interface. To save existing calls for a dened period of SS7 link short time failure, the timer values at BSC and MSC side should be equal. 11. After a TDPC SWITCH the timer TIAS and TIAR at BSC side are reset to 0. Under disadvantageous conditions, it may happen that no inactivity test message will be sent towards MSC for more than 2 times of the TIAS interval. To prevent that the MSCreleases the SCCP connections, the TIARtimer fromthe MSCshould be more than 2 times of the TIAS timer fromthe BSC. Please note that, if several switchs are performed in a short period of time, the above mentioned conditions are not suf- cient anymore. 12. The SCCP timer TGUARD has to be set with respect to the procedure of TDPC switch. During this switch the SS7-links at the A-interface are initialized and there- fore timer TGUARD has to be set bigger than 30 seconds. Recommended value is 50 seconds. In the case TGUARD expires the BSSMAP reset procedure will be performed which leads to loss of all calls. Please don't forget to set the appropriate MSC timer accordently. 13. The timer TGUARD must be set longer than ALARMT2 (LICD object) + TSBS. Shorter values are useless and can cause a reset procedure at A interface also for very short link interruption due to the time needed to complete the link realignment. The TGUARD timer is used to supervise the Adjacent Signalling Point inacessibility. It is started when the last SS7 goes down and it is stopped only when the rst link is completely aligned. The procedure to get to the complete alignment takes the following steps: if the failure lasts longer than ALARMT2 (LICD object, default 1 sec.); at the end of the failure the PCM is up at the expiration of the timer ALARMT1 (LICD object, default 20 sec.); after M3T17 (default 1 sec.) plus M2T4E (default 500 ms.) the level 2 is in service; the SLTM - SLTA message are exchanged between the 2 network elements; after that the SST - SSA messages are exchanged between BSC and MSC also the SCCP is aligned. The BSC sends the SST message when receives the SST from MSC or when the TSBS timer expires. The alignment procedure is considered completed and the timer TGUARD is stopped, only after receiving the SSA from the MSC. 14. As during TDPC switch SS7 links are initialized, it is recommandable to set TGUARD at a value of 50 secs in order to allow proper behaviour during load condi- tions too. 15. Depending on the value of the attribute SS7MTPTYP some timers of the OPCobject have different ranges, as shown in the following table: Timer Name ANSI Range CCITT Range M3T22OR20 18-24 36-72 M3T23OR31 18-24 36-72 626 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Create OPC:NAME=OPC:0=,SS7MTPTYP=ANSI,OPC=3-5-10, MSCSPC=2-4-8,NTWIND=NAT0,BSSAPSSN=30,MSCPERTFLAG=FALSE, M2T1=400,M2T2=50,M2T3=10,M2T4N=75,M2T4E=4,M2T5=1, M2T6=30,M2T7=5,FLOWCTH=0,CONGTH=0,SANITIME=0, ERRCORMTD=BASIC_ERROR_CORRECTION,N1=110,N2=2000,TCONN=0, TIAS=0,TIAR=0,TREL=0, TGUARD=0,TSBS=0,TWCUSER=0,TINT=0,SMLCSPC=1- 23-3,APLESSNBSC=<DEFAULT>,APLESSNSMLC=<DEFAULT>, SMLCPERTFLAG=TRUE,M3T10=<DEFAULT>; DELETE OPC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL OPC DELETE OPC Applicability: Phase 2. Visibility level 2. Command Description: This command deletes an OPC previously created through the CREATE OPC command. The validity range of the object address "bscn" can be found in Appendix A. System Responses: Application Guidelines: None. Parameter ANSI CCITT TCONN 1-72 0-255 TIAS 60-120 0-255 TIAR 132-255 0-255 TREL 20-40 0-255 DELETE OPC: NAME=OPC:bscn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_SUBORDINATE_EQUIPPED All equipped SS7 data links must be deleted before submit- ting the command: no SS7L can be equipped. A30808-X3247-L230-3-7619 627 Commands Base Station Controller CML:BSC Example of Command Execution Delete OPC:NAME=OPC:0; GET OPC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL OPC GET OPC Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of the timers for MTP Level 2 and Level 3 Protocol of the Common Channel Signalling System SS7. The validity range of the object address "bscn" can be found in Appendix A. System Responses: GET OPC: NAME=OPC:bscn [,REQATTL=SS7MTPTYP, OPC, MSCSPC, NTWIND, BSSAPSSN, MSCPERTFLAG, T1UNIT, M2T1, T2UNIT, M2T2, T3UNIT, M2T3, T4NUNIT, M2T4N, T4EUNIT, M2T4E, T5UNIT, M2T5, T6UNIT, M2T6, T7UNIT, M2T7, FLOWCTH, CONGTH, SANUNIT, SANTIME, ERRCORMTD, N1, N2, T1UNIT1, M3T1, T2UNIT1, M3T2, T3UNIT1, M3T3, T4UNIT, M3T4, T5UNIT1, M3T5, T12UNIT, M3T12, T13UNIT, M3T13, T14UNIT, M3T14, T17UNIT, M3T17, T19UNIT, M3T19, T22OR20UNIT, M3T22OR20, T23OR21UNIT, M3T23OR21, T1TMUNIT, M3T1TM, T2TMUNIT, M3T2TM, TCONNUNIT, TCONN, TIASUNIT, TIAS, TIARUNIT, TRELUNIT, TREL, TGUARDUNIT, TGUARD, TSBSUNIT, TSBS, TWCUNIT, TWCUSER, TINTUNIT, TINT, SMLCSPC, APLESSNBSC, APLESSNSMLC, SMLCPERTFLAG, T10UNIT, M3T10]; GET ACK: USER NAME: sag COMMAND: Get OPC:NAME=OPC:0; SW RELEASE: 02-06-03-01-00-04_02-05-20 COMMAND RESULT: OPERATION COMPLETED SS7MTPTYP: ss7MtpType OPC: NetworkClusterMember: NetworkClusterMember NetworkCluster: NetworkCluster MSCSPC: networkClusterMember: networkClusterMember networkCluster: networkCluster networkIndicator: networkIndicator 628 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BSSAPSSN: bssapSsn MSCPERTFLAG: mscPeriodicTestFlag T1UNIT: MS100 (read only) M2T1: mt12Timer1 T2UNIT: MS100 (read only) M2T2: mt12Timer2 T3UNIT: MS100 (read only) M2T3: mt12Timer3 T4NUNIT: MS100 (read only) M2T4N: mt12Timer4N T4EUNIT: MS100 (read only) M2T4E: mt12Timer4E T5UNIT: MS100 (read only) M2T5: mt12Timer5 T6UNIT: MS100 (read only) M2T6: mt12Timer6 T7UNIT: MS100 (read only) M2T7: mt12Timer7 FLOWCTH: flowcThreshold CONGTH: congThreshold Sanity UNIT: MS100 (read only) Sanity Timer: sanityTimer ERRCORMTD: CCSS7 ErrorCorrectionMethod N1: n1 N2: n2 T1UNIT1: MS100 (read only) M3T1: mt13Timer1 T2UNIT1: MS100 (read only) M3T2: mt13Timer2 T3UNIT1: MS100 (read only) M3T3: mt13Timer3 T4UNIT: MS100 (read only) M3T4: mt13Timer4 T5UNIT1: MS100 (read only) M3T5: mt13Timer5 T12UNIT: MS100 (read only) M3T12: mt13Timer12 T13UNIT: MS100 (read only) M3T13: mt13Timer13 T14UNIT: MS100(read only) M3T14: mt13Timer14 T17UNIT: MS100 (read only) M3T17: mt13Timer17 T19UNIT: SEC5 (read only) M3T19: mt13Timer19 T22OR20UNIT: SEC5 (read only) M3T22OR20: mt13Timer22or20 A30808-X3247-L230-3-7619 629 Commands Base Station Controller CML:BSC Application Guidelines: Allowed Timer Units are: Example of Command Execution Get OPC:NAME=OPC:0,REQATTL=SS7MTPTYP&OPC&MSCSPC&NTWIND& BSSAPSSN&MSCPERTFLAG&T1UNIT&M2T1&T2UNIT&M2T2&T3UNIT& M2T3&T4NUNIT&M2T4N&T4EUNIT&M2T4E&T5UNIT&M2T5&T6UNIT&M2T6& T7UNIT&M2T7&FLOWCTH&CONGTH&SANUNIT&SANTIME&ERRCORMTD&N1& N2&T1UNIT1&M3T1&T2UNIT1&M3T2&T3UNIT1&M3T3&T4UNIT&M3T4&T5UNIT1& M3T5& T12UNIT&M3T12&T13UNIT&M3T13&T14UNIT&M3T14&T17UNIT&M3T17& T19UNIT&M3T19&T22OR20UNIT&M3T22OR20&T23OR21UNIT&M3T23OR21& T1TMUNIT&M3T1TM&T2TMUNIT&M3T2TM&TCONNUNIT&TCONN&TIASUNIT& TIAS&TIARUNIT&TIAR&TRELUNIT&TREL&TGUARDUNIT&TGUARD&TSBSUNIT& TSBS&TWCUNIT&TWCUSER&TINTUNIT&TINT&SMLCSPC&APLESSNBSC& APLESSNSMLC&SMLCPERTFLAG&M3T10; T23OR21UNIT: SEC5 (read only) M3T23OR21: mt13Timer23or21 T1TMUNIT: MS100 (read only) M3T1TM mt13Timer1TM T2TMUNIT SEC5 (read only) M3T2TM mt13Timer2TM TCONNUNIT: SEC5 (read only) TCONN: tconn TIASUNIT: SEC5 (read only) TIAS: tias TIARUNIT: SEC5 (read only) TIAR: tiar TRELUNIT: HLFSEC (read only) TREL: trel TGUARDUNIT: SEC5 (read only) TGUARD: tGuard TSBSUNIT: HLFSEC (read only) TSBS: tsbs TWCUNIT: HLFSEC (read only) TWCUSER: twcUser TINTUNIT: SEC5 (read only) TINT: tint SMLCSPC: sMLCSignallingPointCode APLESSNBSC: applPartSSNLCSEBSC APLESSNSMLC: applPartSSNLESMLC SMLCPERTFLAG: sMLCPeriocTestFlag T10UNIT: MS100 (read only) M3T10: mtl3Timer10 MS100 hundred of milliseconds SEC5 5 seconds HLFSEC half seconds. 630 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET OPC BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL OPC GET OPC BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "bscn" can be found in Appendix A. System Responses: Application Guidelines: Allowed Timer Units are: Example of Command Execution Get OPC BASICS:NAME=OPC:0; GET OPC BASICS: NAME=OPC:bscn; GET ACK : NAME: name MSCPERTFLAG: mscPeriodicTestFlag TCONN: tconn TIAS: tias TIAR: tiar TREL: trel TGUARD: tGuard TSBS: tsbs TWCUSER: twcUser TINT: tint SMLCSPC: sMLCSignallingPointCode APLESSNBSC: applPartSSNLCSEBSC APLESSNSMLC: applPartSSNLESMLC SMLCPERTFLAG: sMLCPeriocTestFlag M3T10: mtl3Timer10 MS100 hundred of milliseconds SEC5 5 seconds HLFSEC half seconds. A30808-X3247-L230-3-7619 631 Commands Base Station Controller CML:BSC GET OPC MTL2 Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL OPC GET OPC MTL2 Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the MTL2 group. The validity range of the object address "bscn" can be found in Appendix A. System Responses: Application Guidelines: Allowed Timer Units are: Example of Command Execution Get OPC MTL2:NAME=OPC:0; GET OPC: NAME=OPC:opcn; GET ACK: NAME: name M2T1: mtl2Timer1 M2T2: mtl2Timer2 M2T3: mtl2Timer3 M2T4N: mtl2Timer4N M2T4E: mtl2Timer4E M2T5: mtl2Timer5 M2T6: mtl2Timer6 M2T7: mtl2Timer7 FLOWCTH: flowcThreshold CONGTH: congThreshold SANTIME: sanityTimer ERRCORMTD: CCSS7 ErrorCorrectionMethod N1: n1 N2: n2 MS100 hundred of milliseconds SEC5 5 seconds HLFSEC half seconds. 632 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET OPC MTL3 Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL OPC GET OPC MTL3 Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the MTL3 group. The validity range of the object address "bscn" can be found in Appendix A. System Responses: Application Guidelines: Allowed Timer Units are: Example of Command Execution Get OPC MTL3:NAME=OPC:0; GET OPC MTL3: NAME=OPC:bscn; GET ACK: NAME: name M3T1: mtl3Timer1 M3T2: mtl3Timer2 M3T3: mtl3Timer3 M3T4: mtl3Timer4 M3T5: mtl3Timer5 M3T12: mtl3Timer12 M3T13: mtl3Timer13 M3T14: mtl3Timer14 M3T17: mtl3Timer17 M3T19: mtl3T19 M3T22OR20: mtl3T22or20 M3T23OR21: mtl3T23or21 M3T1TM: mtl3T1TM M3T2TM: mtl3T2TM MS100 hundred of milliseconds SEC5 5 seconds HLFSEC half seconds. A30808-X3247-L230-3-7619 633 Commands Base Station Controller CML:BSC GETINFO OPC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL OPC GETINFO OPC Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: Links on A interface; Links on Lb interface; Status of MSC-SPC; Status of SMLC-SPC; Status of congestion of MSC; Level of congestion of MSC; Status of congestion of SMLC; Level of congestion of SMLC. The validity range of the object address "bscn" can be found in Appendix A. System Responses: GETINFO OPC ACK: BSC_CONTROLLER -> LMT_LOCAL 11:41:14 22/03/1999 *** INFORMATION *** GETINFO REPORT OPC: NAME = OPC:0 SS7L ON AINT: 6 SS7L ON LBINT: 1 MSC-SPC STATUS: MTP_INACCESSIBLE SMLC-SPC STATUS MTP: INACCESSIBLE MSC CONGESTION STATUS: MTP_NOT_CONGESTED MSC CONGESTION LEVEL: 0 SMLC CONGESTION STATUS: MTP_NOT_CONGESTED SMLC CONGESTION LEVEL: 0 SCCP-MSC-BSSAP: SCCP_PROHIBITED SCCP-SMLC-BSSAP-LE: SCCP_PROHIBITED GETINFO OPC: NAME=OPC:opcn; 634 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SMG-MSC-BSSAP TEST IN PROGRESS: FALSE SMG-SMLC-BSSAP-LE TEST IN PROGRESS: FALSE TL3-AINT SW STATE: 10 TL3-LBINT SW STATE: 10 TL3-ABIS SW STATE: 10 SCCP-AINT SW STATE: 10 SCCP-LBINT SW STATE: 10 END OF REPORT GETINFO OPC NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack OPC: name = OPC:0 nackCause = <nack cause> Application Guidelines: The attribute relatedFiles displays only the file name without the complete BSC disk storage path. Example of Command Execution Getinfo OPC:NAME=OPC:0; NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. A30808-X3247-L230-3-7619 635 Commands Base Station Controller CML:BSC SET OPC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL OPC SET OPC Applicability: Phase 2. Visibility level 2. Command Description: This command sets the timer values for MTP Level 2 and Level 3 Protocol of the Common Channel Signalling System (SS7) as well as the threshold values used in the PPCC. The validity range of the object address "bscn" can be found in Appendix A. System Responses: Application Guidelines: 1. At least one eld of the OPC attribute must be different from the corresponding one of the SPC attribute. 2. In CCITT case the subeld NetworkIdentier of MSCSPC attributes is not cong- urable, while in ANSI case it is mandatory. SET OPC: NAME=OPC:bscn [,MSCSPC=] [,MSCPERTFLAG=] [,TCONN=] [,TIAS=] [,TIAR=] [,TREL=] [,TGUARD=] [,TSBS=] [,TWCUSER=] [,TINT=] [,SMLCSPC=] [,APLESS- NBSC=] [,APLESSNSMLC=] [,SMLCPERTFLAG=] [,M2T1=] [,M2T2=] [,M2T3=] [,M2T4N=] [,M2T4E=] [,M2T5=] [,M2T6=] [,M2T7=] [,FLOWCTH=] [,CONGTH=] [,SANTIME=] [,ERRCORMTD=] [,N1=] [,N2=] [,M3T1=] [,M3T2=] [,M3T3=] [,M3T4=] [,M3T5=] [,M3T12=] [,M3T13=] [,M3T14=] [,M3T17=] [,M3T19=] [,M3T22OR20=] [,M3T23OR21=] [,M3T1TM=] [,M3T2TM=] [,M3T10=]; SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_INVALID_ATTRIBUTES Make reference to Application Guidelines n. 1, n. 2, n. 5, n. 7, n. 14, n. 15, n. 16. UNSUCCESSFUL_VAR_OUT_OF_RANGE Make reference to Application Guidelines n.3, n. 4, n. 6, n. 13, n. 17. UNSUCCESSFUL_LINKSET_ONE_CONNECTED When SS7L links are congured on linkset 1 the attribute SMLCSPC cannot be set at NULL. 636 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 3. Depending on the value of the attribute SS7MTPTYP of the CREATE command, the subelds of MSCSPC have different ranges, as shown in the following table: 4. Depending on the value of the attribute SS7MTPTYP of OPC object the timers (except M2T5 timer) have different ranges, as shown in the following table: The value assigned to M2T6 timer must be lower or equal to the M3T1TM one. 5. The following tables show the possible values for CONGTHRE and FLOWCTH parameters and the related percentage of transmit buffer used which cause the request of load reduction measures or the subsequently discarding of messages. 6. Depending on the value of the attribute SS7MTPTYP of OPC object, the timers M3T22OR20 an M3T22OR21 have different ranges, as shown in the following table ANSI CCITT Network Cluster Member 1-255 0-255 Network Cluster 0-255 0-63 Network Identifier 1-254 NO_CONFIG Timer Name ANSI Range CCITT Range M2T1 129-160 400-500 M2T2 50-300 50-1500 M2T3 50-140 10-15 M2T4N 15-30 75-95 M2T4E 4-7 4-5 M2T6 10-60 30-60 M2T7 5-20 5-20 CONGTHRE (congestion control threshold) FLOWCTH (flow control threshold) value abatment onset discard value abatment onset 0 = = = 0 = = 1 45 50 not used 1 50 60 2 45 50 55 2 50 65 3 30 35 40 3 50 70 4 35 40 45 4 40 50 5 40 45 50 5 40 55 6 45 50 55 6 40 60 7 45 55 8 45 60 9 45 65 Tab. 2.5 Congestion and Flow Control Thresholds Timer Name ANSI Range CCITT Range M3T22OR20 18-24 36-72 M3T23OR31 18-24 36-72 A30808-X3247-L230-3-7619 637 Commands Base Station Controller CML:BSC 7. The value assigned to M3T1TM timer must be greater or equal to the M2T6 one (timer of OPC object). 8. If a link interruption shorter than TGUARD timer value occurs, busy CIC's will not be released; i.e. existing speech connections will be saved. After link re-alignment (MTP) no reset message will be sent on the A-interface. If a link interruption longer than TGUARD timer value occurs, the existing speech connections will be released and after link re-alignment a reset message will be sent on theA-interface. To save existing calls for a dened period of SS7 link short time failure, the timer values at BSC and MSC side should be equal. 9. After a TDPC SWITCH the timers TIAS and TIAR at BSC side are reset to 0. Under disadvantageous conditions, it may happen that no inactivity test message will be sent towards MSC for more than 2 times of the TIAS interval. To prevent that the MSCreleases the SCCP connections, the TIARtimer fromthe MSCshould be more than 2 times of the TIAS timer fromthe BSC. Please note that, if several switchs are performed in a short period of time, the above mentioned conditions are not suf- cient anymore. 10. The SCCP timer TGUARD has to be set with respect to the procedure of TDPC switch. During this switch the SS7-links at the A-interface are initialized and there- fore timer TGUARD has to be set bigger than 30 seconds. Recommended value is 50 seconds. In the case TGUARD expires the BSSMAP reset procedure will be performed which leads to loss of all calls. Please don't forget to set the appropriate MSC timer accordently. 11. The timer TGUARD must be set longer than ALARMT2 (LICD object) + TSBS. Shorter values are useless and can cause a reset procedure at A interface also for very short link interruption due to the time needed to complete the link realignment. The TGUARD timer is used to supervise the Adjacent Signalling Point inacessibility. It is started when the last SS7 goes down and it is stopped only when the rst link is completely aligned. The procedure to get to the complete alignment takes the following steps: if the failure lasts longer than ALARMT2 (LICD object, default 1 sec.); at the end of the failure the PCM is up at the expiration of the timer ALARMT1 (LICD object, default 20 sec.); after M3T17 (default 1 sec.) plus M2T4E (default 500 ms.) the level 2 is in service; the SLTM - SLTA message are exchanged between the 2 network elements; after that the SST - SSA messages are exchanged between BSC and MSC also the SCCP is aligned. The BSC send the SST message when receives the SST from MSC or when the TSBS timer expires. The alignment procedure is considered completed and the timer TGUARD is stopped, only after receiving the SSA from the MSC. 12. As during TDPC switch SS7 links are initialized, it is recommandable to set TGUARD at a value of 50 secs in order to allow proper behaviour during load condi- tions too. 13. Depending on the value of the attribute SS7MTPTYP some timers of the OPCobject have different ranges, as shown in the following table: Parameter ANSI CCITT TCONN 1-72 0-255 TIAS 60-120 0-255 TIAR 132-255 0-255 TREL 20-40 0-255 638 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 14. OPC, MSCSPC and SMLCSPC attributes must differ fromeach other in at least one eld. 15. In CCITT case the subeld NetworkIdentier of OPC, MSCSPC and SMLCSPC attributes is not congurable, while in ANSI case it is mandatory. 16. If the attribute SS7MTPTYP is set to ANSI, the attributeNetworkCluster cannot assume value 0 if 0<NIDEN<6. 17. Depending on the value of the attribute SS7MTPTYP the subelds of the attributes OPC, MSCSPC and SMLCSPC have different ranges, as shown in the following table: 18. Before setting the ERRCORMTD parameter at PREVENTIVE_CYCLIC_RETRANS_ERR_CORR value the SS7L and PPCC objects must be put in LOCKED state. Example of Command Execution Set OPC:NAME=OPC:0,MSCSPC=2-4-8,MSCPERTFLAG=FALSE, M2T1=400,M2T2=50,M2T3=10, M2T4N=75,M2T4E=4,M2T5=1,M2T6=30,M2T7=5,FLOWCTH=0,CONGTH=0, SANITIME=0, ERRCORMTD=BASIC_ERROR_CORRECTION,N1=110, N2=2000,TCONN=0,TIAS=0,TIAR=0,TREL=0, TGUARD=0,TSBS=0,TWCUSER=0, TINT=0,SMLCSPC=1-23-3,APLESSNBSC=<DEFAULT>, APLESSNSMLC=<DEFAULT>,SMLCPERTFLAG=TRUE,M3T10=<DEFAULT>; ANSI CCITT Network Cluster Member 1-255 0-255 Network Cluster 0-255 0-63 Network Identifier 1-254 NO_CONFIG A30808-X3247-L230-3-7619 639 Commands Base Station Controller CML:BSC PCMA The PCMA object represents one of the PCMlines from/to MSC (A interface), departing from the TRAU. CREATE PCMA Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMA CREATE PCMA Applicability: Phase 2. Visibility level 2. Command Description: This command adds a 2 Mbit PCM line on the "A" interface (PCMA) specifying its parameters. It associates a PCMA with a given PCMT identified by the Transcoder and Rate Adapter Unit (TRAU) number and the circuit number. The validity range of the object address "pcman" can be found in Appendix A. System Responses: CREATE PCMA: NAME=PCMA:pcman, PCMT= [,CRC=] [,BER=] [,HCICN=] [,LOWBER=] [,DEFPOOLTYP=] [,CODE=] [,NUA=] [,BAF=] [,REMAL=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The TRAU object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES Make reference to Application Guidelines n. 1, n. 2, n. 4, n. 5, n. 6, n. 7, n. 9, n. 10, n. 11. UNSUCCESSFUL_INVALID_STATUS Before deleting a PCMA, the relative TRAU object instance must be in LOCKED state. NOT_ENOUGH_SUBSLOTS_IN_PCMS In order to create a PCMA there must be enough PCMS sublots still unmapped to fulll the request of the new PCMA, depending on the DEFPOOLTYP attribute. 640 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. No PCM line has to be connected to the circuit number "circn" of TRAU. 2. The HCIC attribute value has to be a unique identier for a PCM line on the "A" interface. 3. After the creation of the object, the ADMINISTRATIVE state of this object is set at LOCKED. An UNLOCK command is required to put this object in service. 4. The attribute REMAL can be set only with the PCM24 lines (parameter "Pcm Type" of the BSC object). 5. The value assigned to LOWBER attribute must be greater or equal to the BER one. This means that the bit error rate for LOWBER is lower or equal than BER one. E.g. LOWBER=3 , BER=2. 6. The attributes CODE, NUA and BAF can be set only with the PCM30 lines (param- eter PCMTYPE of BSC object). 7. The HCICN attribute cannot assume a value greater than 2047 if the attribute CICFM of the BSC object is set at GSM. 8. For PCM24 lines, the LOWBER threshold can be congured not depending on the type of line interface cards that are being used.However, the alarm for exceeded LOWBER canbe detected only by the MSCI V2 (on TRAU side, for the PCMA). Nevertheless, if these cards are not of the correct edition, there will not be any misbehaviour, except for the fact that, on the network element where the line interface cards is not able to handle this alarm, the related error messages will never be sent to LMT and OMC. 9. When pooling is disabled DEFPOOLTYP attribute cannot be set. 10. If TRAU is AMR the attribute DEFPOOLTYP must be set at POOL_23 or POOL_46, and if TRAU is not AMR the attribute DEFPOOLTYP must not be set at POOL_23 or POOL_46. 11. If TRAU is not S3 (fourth digit of EXPSWV attribute is not 03), the attribute DEFPOOLTYP cannot assume the values from POOL_24 to POOL_35 and the values POOL_47 and POOL_48. Example of Command Execution if PCM30: Create PCMA:NAME=PCMA:2,PCMT:0-3,CRC=FALSE,CODE=AMI,NUA=TRUE, BER=E10_3,BAF=254,HCICN=5,LOWBER=E10_3,DEFPOOLTYP=POOL_1; if PCM24: Create PCMA:NAME=PCMA:2,PCMT:0-3,CRC=FALSE,BER=E10_3,HCICN=5, LOWBER=E10_3,REMAL=CCITT,DEFPOOLTYP=POOL_1; if CICFM=NOTSTRUCT: Create PCMA:NAME=PCMA:2,PCMT:0-3,CRC=FALSE,BER=E10_3,HCICN=2600, LOWBER=E10_3,REMAL=CCITT,DEFPOOLTYP=POOL_1; if CICFM=GSM: Create PCMA:NAME=PCMA:2,PCMT:0-3,CRC=FALSE,BER=E10_3,HCICN=500, LOWBER=1,REMAL=CCITT,DEFPOOLTYP=POOL_1; A30808-X3247-L230-3-7619 641 Commands Base Station Controller CML:BSC DELETE PCMA Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMA DELETE PCMA Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a 2 Mbit PCM line on the "A" interface (PCMA) previously created through the CREATE PCMA command. The validity range of the object address "pcman" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete PCMA:NAME=PCMA:2; DELETE PCMA: NAME=PCMA:pcman; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_LINK_CONNECTED No signalling link (O&M, SS7) has to be implemented on the PCM line. Every NUC instance related to the PCM line must be deleted before. UNSUCCESSFUL_INVALID_STATUS Before deleting a PCMA, the relative object instance must be in LOCKED state. Before deleting a PCMA, the relative TRAU object instance must be in LOCKED state. 642 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET PCMA Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMA GET PCMA Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameters of a 2 Mbit PCM line on the "A" interface previously created through the CREATE PCMA command. The validity range of the object address "pcman" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get PCMA:NAME=PCMA:0,REQATTL=PCMT&CRC&CODE&NUA&BER&BAF& HCICN&LOWBER&REMAL&DEFPOOLTYP&TOPOREL; GET PCMA: NAME=PCMA:pcman [,REQATTL=PCMT, CRC, CODE, NUA, BER, BAF, HCICN, LOWBER, REMAL, DEFPOOLTYP, TOPOREL]; GET ACK: NAME: name PCMT: Traun: traun Circn: circn CRC: crc CODE: code for PCM24 line No-Config is displayed NUA: nua for PCM24 line No-Config is displayed BER: ber BAF: baf for PCM24 line No-Config is displayed HCICN: hCICN LOWBER: lowerBitErrorRate REMAL: remoteAlarmType for PCM30 line No-Config is displayed DEFPOOLTYP: defPoolType TOPOREL: topologicalRelationship GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 643 Commands Base Station Controller CML:BSC GET PCMA BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMA GET PCMA BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "pcman" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get PCMA BASICS:NAME=PCMA:0; GET PCMA PCM24 Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMA GET PCMA PCM24 GET PCMA BASICS: NAME=PCMA:pcman; GET ACK: NAME: name PCMT: Traun: traun Circn: circn CRC: crc BER: ber HCICN: hCICN LOWBER: lowerBitErrorRate DEFPOOLTYP: defaultPoolType GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. GET PCMA PCM24 NAME=PCMA:pcman; 644 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameters of a PCM24 line on the "A" interface. The validity range of the object address "pcman" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get PCMA PCM24:NAME=PCMA:0; GET PCMA PCM30 Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMA GET PCMA PCM30 Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameters of a PCM30 line on the "A" interface. The validity range of the object address "pcman" can be found in Appendix A. System Responses: GET ACK: NAME: name REMAL: remoteAlarmType GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. GET PCMA PCM30 NAME=PCMA:pcman; GET ACK: NAME: name CODE: code NUA: nua BAF: baf A30808-X3247-L230-3-7619 645 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get PCMA PCM30:NAME=PCMA:0; GET PCMA STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMA GET PCMA STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the PCMA object: Administrative State (AST) Operational State (OST) Usage State (UST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "pcman" can be found in Appendix A. System Responses: Application Guidelines: Only sets with raised bits are shown. Example of Command Execution Get PCMA STAT:NAME=PCMA:0; GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. GET PCMA STAT: NAME=PCMA:pcman; GET PCMA STAT ACK: GET PCMA STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 646 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETINFO PCMA Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMA GETINFO PCMA Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following information: 1. The states and statuses of the PCMA: AST, OST, AVS, CST. 2. The identity of the SS7, X25A signalling timeslot on the PCMA line. 3. The identity of the NUC timeslot on the PCMA line. 4. The identity of the FRL timeslot on the PCMA line. 5. The total number of trafc channels. 6. The number of idle and busy trafc channels. 7. The PCMT connected with this PCMA. 8. For each timeslot (TSLA) the POOL TYPE associated. The validity range of the object address pcman can be found in Appendix A. System Responses: GETINFO PCMA ACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** INFORMATION *** GETINFO REPORT PCMA: NAME = PCMA:0 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE SS7L TIMESLOT: 16 29 X25A TIMESLOT: NONE NUC TIMESLOT: 1 7 9 FRL TIMESLOT: 2 6 8 TRAFFIC CH (TOTAL): 27 TRAFFIC CH BUSY: 0 TRAFFIC CH IDLE: 27 PCMT: 0 - 0 TSLA NR POOL TYPE GETINFO PCMA: NAME=PCMA:pcman; A30808-X3247-L230-3-7619 647 Commands Base Station Controller CML:BSC 1 POOL_1 2 NOT DEFINED ... ... ... ... 31 NOT DEFINED END OF REPORT GETINFO PCMA NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack PCMA: name = PCMA:0 nackCause = <nack cause> Application Guidelines: None. Example of Command Execution Getinfo PCMA:NAME=PCMA:0; GETRELATIONSHIP PCMA Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMA GETRELATIONSHIP PCMA Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of all the HMOs (Hardware Managed Object) supporting the FMO functionality. For the PCMA object the related HMOs are the following: LICD/LICDS, EPWR, BSMS, NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. GETRELATIONSHIP PCMA: NAME=PCMA:pcman; 648 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TPWR, PPLD, PWRD, MPCC, TDPC, MEMT, NTW and PPXL. The validity range of the object address "pcman" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship PCMA:NAME=PCMA:0; GETSUBO PCMA Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMA GETSUBO PCMA Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "pcman" can be found in Appendix A. System Responses GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. GETSUBO PCMA: NAME=PCMA:pcman; GETSUBO ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GET PCMA STATUS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 649 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Getsubo PCMA:NAME=PCMA:0; LOCK PCMA Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMA LOCK PCMA Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "pcman" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. If object TRX or CHAN is locked, calls using the concerned objects are dropped. To avoid loss of calls by locking objects TRX or CHAN a request for usage state of this objects should be done previously (e.g. GET state status). In case returned usage state is "active" or "busy" locking should not be done (otherwise calls are dropped). 3. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock PCMA:NAME=PCMA:0; LOCK PCMA: NAME=PCMA:pcman; LOCK PCMA ACK: LOCK PCMA NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 650 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SHUTDOWN PCMA Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMA SHUTDOWN PCMA Applicability: Phase 2. Visibility level 1. Command Description: This command allows the graceful transition of an object from the administrative state "Unlocked" to the administrative state "Locked" after the object has terminated its current activity. The systemattempts to performthe command, every 10 seconds for the next 6 minutes. If after the predefined period (5.5 minutes) the current activity is not terminated, the administrative state will be set at Locked. If one of the objects is still active or busy after the predefined period, ongoing calls will be dropped. The validity range of the object address "pcman" can be found in Appendix A. System Responses: Application Guidelines: 1. If the operator has started too many shutdown commands, the system will display the SM TOO BUSY message. 2. Possible state transitions and timing: a) UNLOCKED -immediately-> SHUTTING DOWN ---------- immediately ----------> LOCKED b) UNLOCKED -immediately-> SHUTTING DOWN ---------- 6 minutes and 10 seconds ----------> LOCKED c) UNLOCKED -immediately-> SHUTTING DOWN ---------- after object went to idle state ----------> LOCKED The state changes described above show all the possible transitions when the shut- down command was performed. SHUTDOWN PCMA: NAME=PCMA:pcman; SHUTDOWN PCMA ACK: SHUTDOWN PCMA NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 651 Commands Base Station Controller CML:BSC The rst column of the table gives the situations which are affected by doing a shutdown of an object. Example of Command Execution Shutdown PCMA:NAME=PCMA:1; UNLOCK PCMA Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMA UNLOCK PCMA Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state "Unlocked". The validity range of the object address "pcman" can be found in Appendix A. System Responses: Application Guidelines: Unlocking of BTSM causes a full BTS alignment. Example of Command Execution Unlock PCMA:NAME=PCMA:0; SITUATIONS TRANSITIONS FORCED/NOT FORCED idle object a) busy object but not released after the SHUTDOWN command b) busy object but released after the SHUTDOWN command c) UNLOCK PCMA: NAME=PCMA:pcman; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 652 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PCMB The PCMB object represents one of the PCM lines from/to BTSE (Abis interface). CREATE PCMB Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMB CREATE PCMB Applicability: Phase 2. Visibility level 2. Command Description: This command adds a 2 Mbit PCM line on the "A-bis" interface (PCMB) specifying its parameters. It associates a PCMBwith a given PCML identified by the LICDnumber and the circuit number. The validity range of the object address "pcmbn" can be found in Appendix A. System Responses: CREATE PCMB: NAME=PCMB:pcmbn, PCML= [,CRC=] [,BER=] ,LREDUNEQ= [,L1CTS=] [,LOWBER=] [,WMOD=] [,CODE=] [,NUA=] [,BAF=][,REMAL=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The LICD object instances must be already equipped. UNSUCCESSFUL_LINK_CONNECTED The trunk of the LICDcard corresponding to the referenced line cannot be already connected to a PCM line. If the PCMB line works in Double Trunk Mode both trunk must be free (i.e no PCMline connected to that LICDcircuit), while if the PCMBline works in Single Trunk Mode, the relative trunk of LICD circuit must be free (i.e no PCMB in Single Trunk mode with the same LREDUNEQ and no other PCM in Double Trunk Mode). In order to connect two PCMB lines to a same LICD circuit, both PCMBs must be in Single Trunk Mode and LREDUNEQ attribute must be SIMPLEXAfor one PCMBand SIMPLEXBfor the other. A30808-X3247-L230-3-7619 653 Commands Base Station Controller CML:BSC Application Guidelines: 1. One PCMB is connected to one BTSM (STAR conguration) or several BTSMs (Multidrop orLoop conguration) and the mapping between Physical Radio Channel and Terrestrial Time Slot, on the "A-bis" interface, is congured by the operator in accordance to the CREATE CHAN command. 2. All parameters without default values are mandatory. 3. After the creation of the object, the ADMINISTRATIVE state of this object is set to LOCKED. 4. The attribute REMAL can be set only with the PCM24 lines (parameter PCMTYPE of BSC object). 5. The value assigned to LOWBERattribute must be greather or equal to the BERone. This means that the bit error rate for LOWBER is lower or equal than the BER one. For example: 6. The attributes CODE, NUA and BAF can be set only with the PCM30 lines (param- eter "Pcm Type" of BSC object). 7. For PCM24 lines, the LOWBER threshold can be congured not depending on the type of line interface cards that are being used. However, the alarmof the exceeded LOWBER can be detected only by the QTLP V2 (on the BSC side, for PCMB). Nevertheless, if these cards are not of the correct edition, there will not be any misbehaviour, except for the fact that, on the network element where the line interface card is not able to handle this alarm, the related error messages will never be sent to LMT and OMC. 8. When the L1CTRLTS (layer1ControlTS) parameter is set at the same value as the abisChannel of the BTSM (O&M signalling link), L1CTS parameter, the BTS is out of service and can no more be accessed via RC or BSC (Abis link). The attribute L1CTRLTS has then to be changed via BTSE-LMT (directly connected at BTSE site). 9. The WMOD attribute cannot be set at SINGLE_TRUNK if the network card is different from NTWSNAP or NTWSNAP_STLP. UNSUCCESSFUL_VAR_OUT_RANGE If the eld TSL of the L1CTS attribute is set, also the led SSL must be set.The L1CTS attribute value must be different from the related BTSM O&M signalling link. UNSUCCESSFUL_INVALID_TIME_SLOT The value assigned to the TimeslotN field of the L1TS attribute is not compatible with the PCM line type attribute (parameter PCMTYPE of BSC object). UNSUCCESSFUL_INVALID_ATTRIBUTES Make reference to Application Guidelines n. 4, n. 5, n. 6, n. 9, n. 10. UNSUCCESSFUL_WRONG_LICD_CARD If the network card is different from SNAP_STLP the circuit of the PCML cannot be greater than 3. UNSUCCESSFUL_EXCEED_OBJECT_NBR The maximum number of configurable PCM lines (PCMB + PCMG + PCMS) is 72 with old MPCC or old BSC rack type. LOWBER = 3 (10-6 bit error rate) BER = 2 (10-5 bit error rate). 654 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 10. The WMOD attribute can be set at SINGLE_TRUNK only if the PCMB attribute LREDUNEQ is not set at DUPLEX. Example of Command Execution For PCM30: Create PCMB:NAME=PCMB:0,PCML=0-0,CRC=FALSE,CODE=HDB3, NUA=FALSE, BER=E10_3,BAF=0,LREDUNEQ=DUPLEX,L1CTS=1-2, LOWBER=E10_3; DELETE PCMB Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMB DELETE PCMB Applicability: Phase 2. Visibility level .2 Command Description: This command deletes a 2 Mbit PCM line on the "A-bis" interface (PCMB) previously created through the CREATE PCMB command. The validity range of the object address "pcmbn" can be found in Appendix A System Responses: Application Guidelines: None. DELETE PCMB: NAME=PCMB:pcmbn; DELETE NACK: Successful DELETE NACK: NACK CAUSES: OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_LINK_CONNECTED No O&M signalling link must be implemented on the instance "pcmbn" of the pcmb line. Every NUC instance related to the PCM line must be deleted defore. UNSUCCESSFUL_INVALID_STATUS Before deleting a PCMB, the relative object instance must be in LOCKED state. UNSUCCESSFUL_INVALID_ATTRIBUTES The PCMB lines cannot be connected as PCMCON1 to any BTSM object. A30808-X3247-L230-3-7619 655 Commands Base Station Controller CML:BSC Example of Command Execution Delete PCMB:NAME=PCMB:0; GET PCMB Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC PCMB GET PCMB Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameters of a 2 Mbit PCM line on the "A-bis" interface (PCMB) previously created through a CREATE PCMB command. The validity range of the object address "pcmbn" can be found in Appendix A. System Responses: Application Guidelines: None. GET PCMB: NAME=PCMB:pcmbn [,REQATTL=PCML, CRC, CODE, NUA, BER, BAF, LREDUNEQ, L1CTS, LOWBER, REMAL, WMOD]; GET ACK: NAME: name PCML: pcmLine CRC: crc CODE: code for PCM24 line No-Config is displayed NUA: nua for PCM24 line No-Config is displayed BER: ber BAF: baf for PCM24 line No-Config is displayed LREDUNEQ: lineRedundancyEquipped L1CTS: layer1ControlTimeslot LOWBER: lowerBitErrorRate REMAL: remoteAlarmType WMOD: workingMode GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. 656 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Get PCMB:NAME=PCMB:0,REQATTL=PCML&CRC&CODE&NUA&BER&BAF& LREDUNEQ&L1CTS&LOWBER&REMAL&WMOD; GET PCMB BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC PCMB GET PCMB BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "pcmbn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get PCMB BASICS:NAME=PCMB:0; GET PCMB BASICS: NAME=PCMB:pcmbn; GET ACK: NAME: name CRC: crc CODE: code for PCM24 line No-Config is displayed NUA: nua for PCM24 line No-Config is displayed BER: ber BAF: baf for PCM24 line No-Config is displayed LREDUNEQ: lineRedundancyEquipped L1CTS: layer1ControlTimeslot LOWBER: lowerBitErrorRate REMAL: remoteAlarmType GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 657 Commands Base Station Controller CML:BSC GET PCMB PCM24 Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC PCMB GET PCMB PCM24 Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameters of a 2 PCM24 line on the "A-bis" inter- face (PCMB). The validity range of the object address "pcmbn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get PCMB PCM24:NAME=PCMB:0; GET PCMB PCM30 Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC PCMB GET PCMB PCM30 Applicability: Phase 2. Visibility level 1. GET PCMB PCM24: NAME=PCMB:pcmbn; GET ACK: NAME: name REMAL: remoteAlarmType GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. GET PCMB PCM30: NAME=PCMB:pcmbn; 658 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command is used to retrieve the parameters of a 2 PCM30 line on the "A-bis" inter- face (PCMB). The validity range of the object address "pcmbn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get PCMB PCM30:NAME=PCMB:0; GET PCMB STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMB GET PCMB STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the PCMB object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "pcmbn" can be found in Appendix A. GET ACK: NAME: name CODE: code for PCM24 line No-Config is displayed NUA: nua for PCM24 line No-Config is displayed BAF: baf for PCM24 line No-Config is displayed GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. GET PCMB STAT: NAME=PCMB:pcmbn; A30808-X3247-L230-3-7619 659 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: Only sets with raised bits are shown. Example of Command Execution Get PCMB STAT:NAME=PCMB:0; GETINFO PCMB Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMB GETINFO PCMB Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The states and statuses of the PCMB: AST, OST, AVS, CTS. 2. The Working Mode. 3. The LICD number and LICD circuit which the PCMB line is connected to. 4. The BTSM or the BTSMTD connected with this PCMB line. 5. For both trunks: if equipped, the number of rising edges and the possible presence for each type of alarms. All the alarms information (except the remote alarm indication) contained in this GETINFO is relevant to the signal received by the BSC. Each counter is increased by one each time the BSC detects the rising of that alarm. 6. For each channel on the PCMB line its rate in kb/s (64 or 16 kbits/s). For TD-SCDMA services the timeslots are reported only when the PPXT cards (that support the links) are available. 7. A timeslot map, that summarizes all the objects/attributes (SUBTSLBs, NUC, LPDLM, LPDLMTD) congured on PCMB timeslots. The validity range of the object address pcmb can be found in Appendix A. System Responses: GETINFO REPORT PCMB: <BSS ID> <PCMB NR> 11:41:14 22/03/1999 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED GET PCMB STAT ACK: GET PCMB STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETINFO PCMB: NAME=PCMB:pcmbn; 660 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller AVAILABILITY STATUS: NONE CONTROL STATUS: NONE WORKING MODE: DOUBLE TRUNK LICD CONNECTED: 0-0 BTSM CONNECTED: 0 49 78 BTSMTD CONNECTED: 3 21 TRUNK A EQUIPPED: TRUE PCM-TRUNK-A ALARMS NR.OF RISING EDGES ALARM PRESENT AIS 0 FALSE CEERAL 0 FALSE RAI 1 TRUE EER 0 FALSE LFA 1 FALSE LOS 1 TRUE LCAAL 0 FALSE RNUA 0 FALSE LNUA 0 FALSE B5 0 FALSE TXAL 0 FALSE LBER 0 FALSE SLIP 0 FALSE L1CTS 1 FALSE TRUNK B EQUIPPED: TRUE PCM-TRUNK-B ALARMS NR.OF RISING EDGES ALARM PRESENT AIS 0 FALSE CEERAL 0 FALSE RAI 1 TRUE EER 0 FALSE LFA 1 FALSE LOS 1 FALSE LCAAL 0 FALSE RNUA 0 FALSE LNUA 0 FALSE B5 0 FALSE TXAL 0 FALSE LBER 0 FALSE SLIP 0 FALSE L1CTS 0 FALSE 16 KBIT/S TIMESLOTS: 2 3 5 6 7 8 9 10 11 12 13 14 15 17 19 20 21 23 24 25 26 27 28 30 31 64 KBIT/S TIMESLOTS: 1 16 18 29 TIMESLOT MAP: TS SUBSLOT 0 SUBSLOT 1 SUBSLOT 2 SUBSLOT 3 A30808-X3247-L230-3-7619 661 Commands Base Station Controller CML:BSC 1 STLSB 1-0 STLSB 1-1 STLSB 1-2 STLSB 1-3 2 STLSB 2-1 STLSB 2-2 STLSB 2-3 ... 29 30 STLSB 30-0 31 STLSB 31-2 STLSB 31-3 END OF REPORT GETINFO PCMB NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack PCMB: name = PCMB:0 nackCause = <nack cause> Application Guidelines: 1. The standard alarms, specied in the GSM recommendations, are the following: AIS: Alarm Indication Signal CEERAL: CRC Excessive Error Rate (only QTLP V1) RAI: Remote Alarm Indication EER: Excessive Error Rate LFA: Loss Of Frame Alignment LOS: Loss Of Signal LCAAL: Loss of CRC Alignment (only QTLP V1) LBER: Low BER threshold exceeded (only QTLP V2 and STLP) SLIP: Slip alarm (some PCM frames are lost only QTLP V2 and STLP) As it can be seen, not all the types of LICD (QTLP V1 and V2) handle some of these alarms. 2. The following alarm can be considered proprietary of BSC, and is present only for QTLP V1: TXAL (Transmission Alarm only QTLP V1) The TX alarm is an internal alarm, and reveals a parity alarm on the bit stream that is sent by the switching matrix to the LICD. 3. The L1CTS alarm (Layer 1 Control Time Slot) means that the pattern received by the BSC on the Layer 1 Control Time Slot is different from the pattern that the BSC has sent to the BTS on the same time slot (this pattern is 0x01). This alarm can arise when a remote interruption, which occurs in the external network, is not detected by means of the standard alarms, due to the fact that the NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. 662 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller network is not transparent for the time slot 0. This alarm is handled only for the PCMB lines, for which the Layer 1 Control Time Slot can be congured in the BSC database. The ltering mechanism for declaring the error rising and ceasing is the same of the other PCM alarms, and uses the ALARMT1 and ALARMT2 parameters of the LICD object (but does not use the ALARMT3 and ALACOUNT). 4. The alarm counters are notied to MPCC by the rmware of the LICD, and they are zeroed when a BSC initialization occurs (full or bring up), when the PCM line is created and when there is a switch of the LICD (from LICD to LICDS or vice versa). The only exceptions are the counters of the SLIP and L1CTS alarms, which are managed by the software of MPCC, and are independent from the LICD which the PCMB is working on. So these two counters are not reset after a switch of LICD. 5. The SLIP alarm, unlikely than the other alarms, is a spot event rather than an alarm state. A "slip" in fact means the loss of one or more layer 1 frames due to the missing synchronization between the two network elements. The "presence" of the SLIP alarmis declared by the MPCC software when 3 frames are lost in an hour, and the alarmdisappears when no frames are lost in 20 minutes. For the SLIP alarmthe counter has the meaning of "number of lost frames since the last BSC initialization or since the creation of the PCM line". 6. For the QTLP V2 with a FW version older than SBS-QF-3-1-06-00, in order to be sure that the counters of the alarms different from L1CTS and SLIP are reset after a switch of LICD, or after a PCMcreation, it is necessary to send, before the switch, a "perform test" command for the LICD or LICDS that is going in service. This is because the older FW versions reset the counters only when the LICD board is reset. Example of Command Execution Getinfo PCMB:NAME=PCMB:0; GETREDSTAT PCMB Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMB GETREDSTAT PCMB Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the State of the links and the configuration of the active channels (received from link A or from link B of the PCM line). This command can be applied to the PCMB lines configured in duplex mode. The validity range of the object address "pcmbn" can be found in Appendix A. GETREDSTAT PCMB: NAME=PCMB:pcmbn; A30808-X3247-L230-3-7619 663 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Get PCMB REDSTAT:NAME=PCMB:1; GETRELATIONSHIP PCMB Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMB GETRELATIONSHIP PCMB Applicability: Phase 2. Visibility level 1. GETREDSTAT PCMB ACK: Successful LKAPCM This attribute is meaningless for the Managed Object PCMB. LKSPCM This attribute represents the State of the link Validity range: linkStatePcm linkAandBOk linkAnotOk linkBnotOk bothNotOk LKCONFPCM This attribute represents the current bit selection. It is meaningful only for PCMB linesBinary values repre- senting the source of data in the PCM line. If the i-th bit is 0 then the i-th channel is receiving data from link A; other- wise from link B. Data will be shown as follows: 7-0 0011001015-8 ..... 127-120 .... GETREDSTAT PCMB NACK: NACK CAUSES: INVALID_COMMAND The syntax of the message received fromLMT is incorrect. OBJECT_NOTEQUIPPED The object instance must be already equipped. PCML_DISABLED_DEPENDENCY The line is disabled because LICD is unavailable, so it can not be monitored. UNSUCCESSFUL_INVALID_ATTRIBUTES The line is congured as simplex. GETRELATIONSHIP PCMB: NAME=PCMB:pcmbn; 664 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of all the HMOs (Hardware Managed Object) supporting the FMO functionality. For the PCMB object the related HMOs are the following: LICD/LICDS, EPWR, PWRD, MPCC, TDPC, MEMT and NTW. The validity range of the object address "pcmbn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship PCMB:NAME=PCMB:0; GETSUBO PCMB Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMB GETSUBO PCMB Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "pcmbn" can be found in Appendix A. GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. GETSUBO PCMB: NAME=PCMB:pcmbn; A30808-X3247-L230-3-7619 665 Commands Base Station Controller CML:BSC System Responses Application Guidelines: None. Example of Command Execution Getsubo PCMB:NAME=PCMB:0; LOCK PCMB Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMB LOCK PCMB Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "pcmbn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). GETSUBO PCMB ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end there a message is displayed noti- fying the end of the subordinate list. GET PCMB STATUS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK PCMB: NAME=PCMB:pcmbn; LOCK PCMB ACK: LOCK PCMB NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 666 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 2. The administrative state LOCKED will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock PCMB:NAME=PCMB:0; SET PCMB Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMB SET PCMB Applicability: Phase 2. Visibility level 2. Command Description: This command modifies a 2 Mbit PCM line LREDUNEQ parameter on the "A-bis" interface (PCMB). The validity range of the object address "pcmbn" can be found in Appendix A. System Responses: SET PCMB: NAME=PCMB:pcmbn [,CRC=] [,LREDUNEQ=] [,L1CTS=] [,BER=] [,LOWBER=] [,BAF=] [,CODE=] [,NUA=] [,REMAL=]; SET ACK: Successful SET NACK: NACK CAUSES: OBJECT_NOTEQUIPPED The object instance must be already equipped. INVALID_COMMAND The LREDUNEQ attribute can be changed only from SIMPLEXA/SIMPLEXB to DUPLEX. No other changes are allowed. UNSUCCESSFUL_INVALID_STATUS When the attributes BAF and CRC4 are changed the PCMB must be in the LOCKED state. Setting of CODE attribute is allowed only if the PCMB is in LOCKED status. UNSUCCESSFUL_VAR_OUT_RANGE The eld SubSlotN of the attribute L1CTS cannot be omitted if the eld TimeSlotN is set. UNSUCCESSFUL_TIME_SLOT_ALREADY_ALLOCATED The time slot assigned to the L1CTS attributes is already allocated. The timeslot chosen for L1CTS is already used by a NUC link. A30808-X3247-L230-3-7619 667 Commands Base Station Controller CML:BSC Application Guidelines: 1. This command fails if all concerned A-bis channels are busy. 2. The attribute BAF can be set only with the PCM30 lines (parameter "Pcm Type" of BSC object). 3. The attribute REMAL can be set only with the PCM24 lines (PCMTYPE attribute of BSC object). 4. The attribute CODEand NUAcan be set only with the PCM30 lines (parameter Pcm Type of BSC object. 5. The value assigned to LOWBER attribute must be greater than or equal to the BER one. This means that the bit error rate for LOWBER is lower or equal than the BER one. For example LOWBER=3(10 -6 bit error rate), BER=2(10 -5 bit error rate). 6. If the PCMB is connected to a BTSM as PCMCON1, then a SET PCMB command removing the Layer 1 Control Timeslot is forbidden. 7. If the PCMB is connected to any BTSMas PCMCON1, then a SET PCMB changing the redundancy conguration from SIMPLEX to DUPLEX is forbidden. 8. When the L1CTRLTS (layer1ControlTS) parameter is set at the same value as the abisChannel of the BTSM (O&M signalling link), L1CTS parameter, the BTS is out of service and can no more be accessed via OMC or BSC (Abis link). The attribute L1CTRLTS has then to be changed via BTSE-LMT (directly connected at BTSE site). Example of Command Execution For PCM30: Set PCMB:NAME=PCMB:0,CRC=FALSE,BAF=1, LREDUNEQ=DUPLEX, L1CTS=1-2, CODE=HDB3,NUA=FALSE,BER=E10_3,LOWBER=E10_3; For PCM24: Set PCMB:NAME=PCMB:0, CRC=FALSE, LREDUNEQ=DUPLEX, L1CTS=1-2, BER=E10_3,LOWBER=E10_3; UNLOCK PCMB Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMB UNLOCK PCMB Applicability: Phase 2. The timeslot chosen for L1CTS is already used by a SUBTSLB object. UNSUCCESSFUL_INVALID_TIME_SLOT The value assigned to the TimeslotNfield of the L1CTRLTS1 attribute is not compatible with the PCM line type attribute (parameter PCMTYPE of BSC object). UNSUCCESSFUL_INVALID_ATTRIBUTES Make reference to Application Guidelines n. 2, n. 3, n. 4, n. 5, n. 7. UNLOCK PCMB: NAME=PCMB:pcmbn; 668 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "pcmbn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock PCMB:NAME=PCMB:0; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 669 Commands Base Station Controller CML:BSC PCMG The PCMG functional object represents the direct physical connection between BSC and SGSN. This line carries 32 time slots of 64 kbit/s that can handle a maximum of 31 FRLs and it can be connected to a single circuit of LICD. The PCMG cannot be redounded. Therefore, unlike the PCMB and PCMS, it does not have the parameter LREDUNEQ. If ASUBENCAP (BSC parameter) is TRUE, then it is possible to create another PCMG or PCMS in the unused trunk (A or B) of the same PCML of the PCMG. Instead, if ASUBENCAP is FALSE, the PCMG takes busy both trunks A and B of the PCML. CREATE PCMG Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMG CREATE PCMG Applicability: Phase 2. Visibility level 2. Command Description: This command creates an instance of the PCMG object class. It can be done only if the LICD is created. Creation of PCMGline means to associate a specific LICD port to a Gb interface connection. The validity range of the object address "pcmgn" can be found in Appendix A. System Responses: CREATE PCMG: NAME=PCMG:pcmgn, PCML= [,CRC=] [,BER=] [,LOWBER=] [,CODE=] [,NUA=] [,BAF=] [,REMAL=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The LICD object instances must be already equipped. UNSUCCESSFUL_LINK_CONNECTED The TRUNK of the LICD card corresponding to the referenced line must not be already connected to a PCM line. UNSUCCESSFUL_EXCEED_OBJECT_NBR The maximumnumber of configurable PCMlines (PCMB + PCMG + PCMS) is 72 with old MPCC or old BSC rack type. 670 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: After the creation of the object the ADMINISTRATIVE state of this object is set at LOCKED. An UNLOCK command is required to put this object in service. Example of Command Execution For PCM30: Create PCMG:NAME=PCMG:0,PCML=0-0-A,CRC=FALSE,CODE=HDB3, NUA=FALSE,BER=0,BAF=0; For PCM24: Create PCMG:NAME=PCMG:3,PCML=1-2-A,CRC=FALSE,CODE=HDB3, NUA=FALSE,BER=0,BAF=0,LOWBER=0,REMAL=CCITT; DELETE PCMG Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMG DELETE PCMG Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a previously created instance of the PCMG object class. It can be done only if all FRL attached to considered PCMG are deleted. The validity range of the object address "pcmgn" can be found in Appendix A. System Responses: UNSUCCESSFUL_INVALID_ATTRIBUTES The attributes REMAL can be set only with the PCM24 lines (parameter PCMTYPE of BSC object). The value assigned to LOWBER attribute must be greater or equal to the BER one. This means that the bit error rate for LOWBER is lower or equal than the BER one. For example: LOWBER = 3 (10- 6 bit error rate) BER = 2 (10-5 bit error rate). The attributes CODE, NUA and BAF can be set only with the PCM30 lines (parameter "Pcm Type" of BSC object). UNSUCCESSFUL_WRONG_LICD_CARD If the network card is different from SNAP_STLP the circuit of the PCML cannot be greater than 3. DELETE PCMG: NAME=PCMG:pcmgn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: A30808-X3247-L230-3-7619 671 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Delete PCMG:NAME=PCMG:0; GET PCMG Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMG GET PCMG Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameter values of an instance of the PCMG object class. The validity range of the object address "pcmgn" can be found in Appendix A. System Responses: OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a PCMG, the relative object instance must be in LOCKED state. SUBORDINATE_EQUIPPED All FRLs attached to this PCMG must be deleted and all the timeslotS related to the PCMG must be free. GET PCMG: NAME=PCMG:pcmgn [,REQATTL= PCML, CRC, CODE, NUA, BER, BAF, LOWBER, REMAL]; GET ACK: NAME: name PCML: pcmLine CRC: crc CODE: code NUA: NotUrgentAlarms BER: BitErrorRate BAF: baf LOWBER: lowerBitErrorRate REMAL: remoteAlarmType GET NACK: 672 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get PCMG:NAME=PCMG:0,REQATTL=PCML&CRC&CODE&NUA&BER&BAF& LOWBER&REMAL; GET PCMG BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMG GET PCMG BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "pcmgn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get PCMG BASICS:NAME=PCMG:0; NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET PCMG BASICS: NAME=PCMG:pcmgn; GET ACK: NAME: name CRC: crc BER: BitErrorRate LOWBER: lowerBitErrorRate GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 673 Commands Base Station Controller CML:BSC GET PCMG PCM24 Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMG GET PCMG PCM24 Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameter values related to the PCM24 lines of the PCMG object class. The validity range of the object address "pcmgn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get PCMG PCM24:NAME=PCMG:0; GET PCMG PCM30 Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMG GET PCMG PCM30 Applicability: Phase 2. Visibility level 1. GET PCMG: NAME=PCMG:pcmgn; GET ACK: NAME: name REMAL: remoteAlarmType GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET PCMG PCM30: NAME=PCMG:pcmgn; 674 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command is used to retrieve the parameter values related to the PCM30 lines of the PCMG object class. The validity range of the object address "pcmgn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get PCMG PCM30:NAME=PCMG:0; GET PCMG STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMG GET PCMG STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the PCMG object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "pcmgn" can be found in Appendix A. GET ACK: NAME: name CODE: code NUA: NotUrgentAlarms BAF: baf GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET PCMG STAT: NAME=PCMG:pcmgn; A30808-X3247-L230-3-7619 675 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Get PCMG STAT:NAME=PCMG:0; GETINFO PCMG Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMG GETINFO PCMG Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The states and statuses of the PCMG: AST, OST, AVS, CTS. 2. The working mode of the PCMG. 3. The LICD and LICD circuit which the PCMG line is connected to. 4. The identity of the FRL timeslot on PCMG line. 5. For both trunks: if equipped, the number of rising edges and the possible presence for each type of alarms. All the alarms information (except the remote alarm indication) contained in this GETINFO is relevant to the signal received by the BSC. Each counter is increased by one each time the BSC detects the rising of that alarm. The validity range of the object address pcmgn can be found in Appendix A. System Responses: GETINFO REPORT PCMG: <BSS ID> <PCMG NR> 11:41:14 22/03/1999 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE WORKING MODE: DOUBLE_TRUNK GET PCMG STAT ACK: GET PCMG STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETINFO PCMG: NAME=PCMG:pcmgn; 676 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller LICD CONNECTED: 0 - 0 FRL TIMESLOT MAP: 1 7 9 TRUNK A EQUIPPED: TRUE PCM-TRUNK-A ALARMS NR.OF RISING EDGES ALARM PRESENT AIS 0 FALSE CEERAL 0 FALSE RAI 1 TRUE EER 0 FALSE LFA 1 FALSE LOS 1 TRUE LCAAL 0 FALSE RNUA 0 FALSE LNUA 0 FALSE B5 0 FALSE TXAL 0 TRUE LBER 0 FALSE SLIP 0 FALSE L1CTS 1 FALSE TRUNK B EQUIPPED: TRUE PCM-TRUNK-B ALARMS NR.OF RISING EDGES ALARM PRESENT AIS 0 FALSE CEERAL 0 FALSE RAI 1 TRUE EER 0 FALSE LFA 1 FALSE LOS 1 FALSE LCAAL 0 FALSE RNUA 0 FALSE LNUA 0 FALSE B5 0 FALSE TXAL 0 TRUE LBER 0 FALSE SLIP 0 FALSE L1CTS 0 FALSE 16 KBIT/S TIMESLOTS: 1 2 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 23 24 25 26 27 28 29 30 31 64 KBIT/S TIMESLOTS: 4 22 END OF REPORT GETINFO PCMG NACK: BSC_CONTROLLER -> LMT_LOCAL A30808-X3247-L230-3-7619 677 Commands Base Station Controller CML:BSC 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack PCMG: name = PCMG:0 nackCause = <nack cause> Application Guidelines: 1. The standard alarms, specied in the GSM recommendations, are the following: AIS: Alarm Indication Signal CEERAL: CRC Excessive Error Rate (only QTLP V1) RAI: Remote Alarm Indication EER: Excessive Error Rate LFA: Loss of Frame Alignment LOS: Loss of Signal LCAAL: Loss of CRC Alignment (only QTLP V1) LBER: Low BER threshold exceeded (only QTLP V2 and STLP) SLIP: Slip alarm (some PCM frames are lost - only QTLP V2 and STLP) As it can be seen, not all the types of LICD (QTLP V1 and QTLP V2) handle some of these alarms. 2. The following alarm can be considered proprietary of BSC, and is present only for QTLP V1): TXAL (Transmission Alarm only QTLP V1) The TX alarm is an internal alarm, and reveals a parity alarm on the bit stream that is sent by the switching matrix to the LICD. 3. The alarm counters are notied to MPCC by the rmware of the LICD, and they are zeroed when a BSC initialization occurs (full or bring up), when the PCM line is created and when there is a switch of the LICD (from LICD to LICDS or vice versa). The only exceptions is the counter of the SLIP, which is managed by the software of MPCC, and is independent from the LICD which the PCMS is working on. So this counter is not reset after a switch of LICD. 4. The SLIP alarm, unlikely than the other alarms, is a spot event rather than an alarm state. A "slip" in fact means the loss of one or more layer 1 frames due to the missing synchronization between the two network elements. The "presence" of the SLIP alarmis declared by the MPCC software when 3 frames are lost in an hour, and the alarmdisappears when no frames are lost in 20 minutes. For the SLIP alarmthe counter has the meaning of "number of lost frames since the last BSC initialization or since the creation of the PCM line". 5. For the QTLP V2 with a FW version older than SBS-QF-3-1-06-00, in order to be sure that the counters of the alarms different from SLIP are reset after a switch of LICD, it is necessary to send, before the switch, a "perform test" command for the NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. 678 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller LICD or LICDS that is going in service. This is because the older FWversions reset the counters only when the LICD board is reset. 6. The information about the 16 kbit/s - 64kbit/s TIMESLOTS is related to the physical usage of the timeslots in a certain moment. This information could be different from the timeslot conguration in the database when the peripheral hardware (PPXU or PPCU or PPXP,according to the conguration) supporting the FRL link related to the involved timeslots is disabled. In this case some timeslots congured as 64 kbit/s in the database are shown as 16 kbit/s timeslots. The example reported in "System Responses:" is due to the following condition: the TIMESLOTS 1..12 have been assigned to FRL: 1 and it results UNLOCKED ENABLED: for this reason the command GETINFO PCMG shows the TIMESLOTS 1..12 as 64 KBIT/S. The TIMESLOTS 13..24 have been assigned to FRL: 0 and it results UNLOCKED/DISABLED/DEPENDENCY because the superordinate PXU or PPCU or PPXP is in DISABLED state, for this reason the command GETINFO PCMG shows the TIMESLOTS 13..24 as 16 KBIT/S. When the FRL: 0 will become UNLOCKED ENABLED, the command GETINFO PCMG will show also the TIMESLOTS 13..24 as 64 KBIT/S. Example of Command Execution Getinfo PCMG:NAME=PCMG:0; GETRELATIONSHIP PCMG Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMG GETRELATIONSHIP PCMG Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of all the HMOs (Hardware Managed Object) supporting the FMO functionality. For the PCMGobject the related HMOs are the following: LICD/LICDS, EPWR, PWRD, MPCC, TDPC, MEMT and NTW. The validity range of the object address "pcmgn" can be found in Appendix A. GETRELATIONSHIP PCMG: NAME=PCMG:pcmgn; A30808-X3247-L230-3-7619 679 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Getrelationship PCMG:NAME=PCMG:0; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. 680 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETSUBO PCMG Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMG GETSUBO PCMG Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "pcmgn" can be found in Appendix A. System Responses Application Guidelines: None. Example of Command Execution Getsubo PCMG:NAME=PCMG:0; LOCK PCMG Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMG LOCK PCMG Applicability: Phase 2. Visibility level 1. GETSUBO PCMG: NAME=PCMG:pcmgn; GETSUBO ACK: The output of the command can be composed by one or more pack with a maximumnumber of three subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GET PCMG STATUS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK PCMG: NAME=PCMG:pcmgn; A30808-X3247-L230-3-7619 681 Commands Base Station Controller CML:BSC Command Description: This command allows to set an object to the administrative state "Locked". All the subordinated units shall be put in Disabled Dependency status. The PCU software shall be informed about unavailability of involved FRL because it has to informthe remote end about new link configuration. The command can cuase services interruption. The validity range of the object address "pcmgn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock PCMG:NAME=PCMG:0; SET PCMG Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMG SET PCMG Applicability: Phase 2. Visibility level 2. Command Description: This command modifies the specific parameters of the PCMG object class. The validity range of the object address "pcmgn" can be found in Appendix A. System Responses: LOCK PCMG ACK: LOCK PCMG NACK: NACK CAUSES: INVALID_STATUS ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. SET PCMG: NAME=PCMG:pcmgn [,CRC=] [,BER=] [,LOWBER=] [,CODE=] [,NUA=] [,BAF=] [,REMAL=]; SET ACK: Successful SET NACK: 682 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution For PCM30: Set PCMG:NAME=PCMG:0,CRC=FALSE,CODE=HDB3,NUA=FALSE,BER=0, BAF=0; For PCM24: Set PCMG:NAME=PCMG:3,CRC=FALSE,CODE=HDB3,NUA=FALSE,BER=0, BAF=0,LOWBER=0,REMAL=CCITT; UNLOCK PCMG Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMG UNLOCK PCMG Applicability: Phase 2. Visibility level 1. Command Description: This command removes the operator block and the unit remains in the operational state as it is at the moment of the command. The PCU software shall be informed about avail- ability of involved FRL because it has to inform the remote end about new link configu- ration. The validity range of the object address "pcmgn" can be found in Appendix A. NACK CAUSES: OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS When the attributes CODE, BAF and CRC are changed the PCMG must be in LOCKED state. UNSUCCESSFUL_INVALID_ATTRIBUTES The attribute REMAL can be set only with the PCM24 lines (parameter PCMTYPE of BSC object). The attributes CODE, NUA and BAF can be set only with the PCM30 lines (parameter PCMTYPE of BSC object). The value assigned to LOWBER attribute must be greater or equal to the BER one. UNLOCK PCMG: NAME=PCMG:pcmgn; A30808-X3247-L230-3-7619 683 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Unlock PCMG:NAME=PCMG:0; UNLOCK ACK: Successful UNLOCK NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_STATUS 684 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PCMS PCMS locates one of the PCM lines from/to TRAU (Asub interface). CREATE PCMS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMS CREATE PCMS Applicability: Phase 2. Visibility level 2. Command Description: This command adds a 2 Mbit PCM line on the Asub interface (PCMS) specifying its parameters. It associates a PCMSwith a given PCML identified by the LICDnumber and the circuit number. The parameter values must be equal to those in the TRAU data base. The validity range of the object address "pcmsn" can be found in Appendix A. System Responses: CREATE PCMS: NAME=PCMS:pcmsn, PCML= [,CRC=] [,BER=] ,LREDUNEQ= [,LOWBER=] [,WMOD=] [,CODE=] [,NUA=] [,BAF=] [,REMAL=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The LICD object instance must be already equipped. UNSUCCESSFUL_WRONG_LICD_CARD If the network card is different from SNAP_STLP the circuit of the PCML cannot be greater than 3. UNSUCCESSFUL_EXCEED_OBJECT_NBR The maximumnumber of configurable PCMlines (PCMB + PCMG + PCMS) is 72 with old MPCC or old BSC rack type. UNSUCCESSFUL_INVALID_ATTRIBUTES Make reference to Application Guidelines n. 3, n. 4, n. 5, n. 7, n. 8. A30808-X3247-L230-3-7619 685 Commands Base Station Controller CML:BSC Application Guidelines: 1. After the creation of the object the ADMINISTRATIVE state of this object is set at LOCKED. An UNLOCK command is required to put this object in service. 2. PCML + LREDUNEQ specify the plug for the PCM line. 3. The attribute REMAL can be set only with the PCM24 lines (parameter PCMTYPE of BSC object). 4. The value assigned to LOWBERattribute must be greather or equal to the BERone. This means that the bit error rate for LOWBER is lower or equal than the BER one. For example: BER=E10 -3 , LOWBER=E10 -5 . 5. The attributes CODE, NUA and BAF can be set only with the PCM30 lines (parameter PCMTYPE of BSC object). 6. For PCMB24 lines, the LOWBER threshold can be congured not depending on the type of line interface cards that are being used. However,the alarm of the exceeded LOWBER can be detected only by the QTLP V2 (on the BSC side, for PCMS), by the BSCI V4 (on the TRAU side, for the PCMS). Nevertheless, if these cards are not of the corrent edition, there will not be any misbehaviour, except for the fact that, on the network element where the line interface card is not able to handle this alarm, the related error messages will never be send to LMT and OMC. 7. The WMOD attribute can be set at SINGLE_TRUNK only if the BSC attribute ASUB- ENCAP is set at TRUE. 8. The WMOD attribute can be set at SINGLE_TRUNK only if the PCMS attribute LREDUNEQ is not set at DUPLEX. Example of Command Execution For PCM30: Create PCMB:NAME=PCMB:0,PCML=0-0,CRC=FALSE,CODE=HDB3, NUA=FALSE, BER=E10_3,BAF=0,LREDUNEQ=DUPLEX,LOWBER=E10_3 For PCM24: Create PCMS:NAME=PCMB:3,PCML=1-2,CRC=FALSE,BER=E10_3, LREDUNEQ=SIMPLEXA, LOWBER=E10_3,REMAL=CCITT; Create PCMS:NAME=PCMS:0,PCML=0-0,LREDUNEQ=SIMPLEXA, WMOD=SINGLE_TRUNK; Create PCMS:NAME=PCMS:1,PCML=0-0, LREDUNEQ=SIMPLEXB, WMOD=SINGLE_TRUNK; UNSUCCESSFUL_LINK_CONNECTED The trunk of the LICD card corresponding to the refer- enced line cannot be already connected to a PCM line. If the PCMS line works in Double Trunk Mode both trunk must be free (i.e no PCM line connected to that LICD circuit), while if the PCMS line works in Single Trunk Mode, the relative trunk of LICD circuit must be free (i.e no PCMS in Single Trunk mode with the same LREDUNEQ and no other PCM in Double Trunk Mode). In order to connect two PCMS lines to a same LICD circuit, both PCMS must be in Single Trunk Mode and LREDUNEQ attribute must be SIMPLEXA for one PCMS and SIMPLEXB for the other. 686 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DELETE PCMS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMS DELETE PCMS Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a 2 Mbit PCM line on the "A-sub" interface (PCMS) previously created through the CREATE PCMS command. The validity range of the object address "pcmsn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete PCMS:NAME=PCMS:0; DELETE PCMS: NAME=PCMS:pcmsn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: OBJECT_NOTEQUIPPED The object instance must be already equipped. SUBORDINATE_EQUIPPED No signalling link (LAPD, SS7, O&M) has to be implemented in the PCM line. All the NUC object instances associated to the PCMS object instance must be previously deleted. UNSUCCESSFUL_INVALID_STATUS Before deleting a PCMS, the relative object instance must be in LOCKED state. A30808-X3247-L230-3-7619 687 Commands Base Station Controller CML:BSC GET PCMS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMS GET PCMS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameters of a 2Mbit PCM line on the "A-sub" interface (PCMS) previously created through a CREATE PCMS command. The validity range of the object address "pcmsn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get PCMS:NAME=PCMS:0,REQATTL=PCML&CRC&CODE&NUA&BER&BAF& LREDUNEQ&LOWBER&REMAL&WMOD&TOPOREL; GET PCMS: NAME=PCMS:pcmsn [,REQATTL= PCML, CRC, CODE, NUA, BER, BAF, LREDUNEQ, LOWBER, REMAL, WMOD, TOPOREL]; GET ACK: NAME: name PCML: pcmLine CRC: crc CODE: code for PCM24 line No-Config is displayed NUA: nua for PCM24 line No-Config is displayed BER: ber BAF: baf for PCM24 line No-Config is displayed LREDUNEQ: lineRedundancyEquipped LOWBER: lowerBitErrorRate REMAL: remoteAlarmType for PCM24 only WMOD: workingMode TOPOREL: topologicalRelationship GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. 688 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET PCMS BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMS GET PCMS BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "pcmsn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get PCMS BASICS:NAME=PCMS:0; GET PCMS PCM24 Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMS GET PCMS PCM24 Applicability: Phase 2. GET PCMS BASICS: NAME=PCMS:pcmsn; GET ACK: NAME: name CRC: crc BER: ber LREDUNEQ: lineRedundancyEquipped LOWBER: lowerBitErrorRate WMOD: workingMode TOPOREL: topologicalRelationship GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. GET PCMS PCM24: NAME=PCMS:pcmsn; A30808-X3247-L230-3-7619 689 Commands Base Station Controller CML:BSC Visibility level 1. Command Description: This command is used to retrieve the parameters of a PCM24 line on the "A-sub" interface (PCMS). The validity range of the object address "pcmsn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get PCMS PCM24:NAME=PCMS:0; GET PCMS PCM30 Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMS GET PCMS PCM30 Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameters of a PCM30 line on the "A-sub" inter- face (PCMS). The validity range of the object address "pcmsn" can be found in Appendix A. System Responses: GET ACK: NAME: name REMAL: remoteAlarmType for PCM24 only GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. GET PCMS PCM30: NAME=PCMS:pcmsn; GET ACK: NAME: name CODE: code NUA: nua BAF: baf 690 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get PCMS PCM30:NAME=PCMS:0; GET PCMS STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMS GET PCMS STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the PCMS object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "pcmsn" can be found in Appendix A. System Responses: Application Guidelines: Only sets with raised bits are shown. Example of Command Execution Get PCMS STAT:NAME=PCMS:1; GET NACK; NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. GET PCMS STAT: NAME=PCMS:pcmsn; GET PCMS STAT ACK: GET PCMS STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object selected must be created. A30808-X3247-L230-3-7619 691 Commands Base Station Controller CML:BSC GETINFO PCMS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMS GETINFO PCMS Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The states and statuses of the PCMS: AST, OST, AVS, CTS. 2. The working mode of the PCMS. 3. The LICD which the PCMS line is connected to and the circuit. 4. The identity of the SS7 signalling timeslots and the LAPD timeslot on the PCMS line. 5. The identity of the X25A signalling timeslots on the PCMS line. 6. The identity of the NUC timeslot on the PCMS line. 7. The identity of the FRL timeslot on the PCMS line. 8. The number of trafc channels. 9. The number of idle and busy channels. 10. The TRAU and PCMT connected with this PCMS line. 11. For both trunks: if equipped, the number of rising edges and the possible presence for each type of alarms. All the alarms information (except the remote alarm indication) contained in this GETINFO is relevant to the signal received by the BSC. Each counter is increased by one each time the BSC detects the rising of that alarm. The validity range of the object address pcmsn can be found in Appendix A. System Responses: GETINFO REPORT PCMS: <BSS ID> <PCMS NR> 11:41:14 22/03/1999 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE WORKING MODE: DOUBLE TRUNK LICD CONNECTED: 0 - 0 (LICD NR - CIRC NR) SS7L TIMESLOT: 16 29 X25A TIMESLOT: NONE LPDL TIMESLOT: 3 NUC TIMESLOT: NONE FRL TIMESLOT: 1 TRAFFIC CH (TOTAL): 27 TRAFFIC CH BUSY: 0 TRAFFIC CH IDLE: 27 GETINFO PCMS: NAME=PCMS:pcmsn; 692 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TRUNK A EQUIPPED TRUE PCM-TRUNK-A ALARMS NR.OF RISING EDGES ALARM PRESENT AIS 0 FALSE CEERAL 0 FALSE RAI 1 TRUE EER 0 FALSE LFA 1 FALSE LOS 1 TRUE LCAAL 0 FALSE RNUA 0 FALSE LNUA 0 FALSE B5 0 FALSE TXAL 0 FALSE LBER 0 FALSE SLIP 0 FALSE L1CTS 1 FALSE TRUNK B EQUIPPED TRUE PCM-TRUNK-B ALARMS NR.OF RISING EDGES ALARM PRESENT AIS 0 FALSE CEERAL 0 FALSE RAI 1 TRUE EER 0 FALSE LFA 1 FALSE LOS 1 FALSE LCAAL 0 FALSE RNUA 0 FALSE LNUA 0 FALSE B5 0 FALSE TXAL 0 FALSE LBER 0 FALSE SLIP 0 FALSE L1CTS 0 FALSE 16 KBIT/S TIMESLOTS: 2 3 5 6 7 8 9 10 11 12 13 14 15 17 19 20 21 23 24 25 26 27 28 30 31 64 KBIT/S TIMESLOTS: 1 16 18 29 END OF REPORT GETINFO PCMS NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack PCMS: name = PCMS:0 nackCause = <nack cause> A30808-X3247-L230-3-7619 693 Commands Base Station Controller CML:BSC Application Guidelines: 1. The standard alarms, specied in the GSM recommendations, are the following: AIS: Alarm Indication Signal CEERAL: CRC Excessive Error Rate (only QTLP V1) RAI: Remote Alarm Indication EER: Excessive Error Rate LFA: Loss of Frame Alignment LOS: Loss Of Signal LCAAL: Loss of CRC Alignment (only QTLP V1) LBER: Low BER threshold exceeded (only QTLP V2 and STLP) SLIP: Slip alarm (some PCM frames are lost only QTLP V2 and STLP) As it can be seen, not all the types of LICD (QTLP V1 and V2) handle some of these alarms 2. The following alarm can be considered proprietary of BSC, and is present only for QTLP V1): TXAL (Transmission Alarm only QTLP V1) The TX alarm is an internal alarm, and reveals a parity alarm on the bit stream that is sent by the switching matrix to the LICD. 3. The alarm counters are notied to MPCC by the rmware of the LICD, and they are zeroed when there is a BSC initialization (full or bring up), when the PCM line is created and when there is a switch of the LICD (from LICD to LICDS or vice versa). The only exception is the counter of the SLIP, which is managed by the software of MPCC, and is independent from the LICD which the PCMS is working on. So these two counters are not reset after a switch of LICD. 4. The SLIP alarm, unlikely than the other alarms, is a spot event rather than an alarm state. A "slip" in fact means the loss of one or more layer 1 frames due to the missing synchronization between the two network elements. The "presence" of the SLIP alarmis declared by the MPCC software when 3 frames are lost in an hour, and the alarmdisappears when no frames are lost in 20 minutes. For the SLIP alarmthe counter has the meaning of "number of lost frames since the last BSC initialization or since the creation of the PCM line". 5. For the QTLP V2 with a FW version older than SBS-QF-3-1-06-00, in order to be sure that the counters of the alarms different from SLIP are reset after a switch of LICD, it is necessary to send, before the switch, a "perform test" command for the LICD or LICDS that is going in service. This is because the older FWversions reset the counters only when the LICD board is reset. NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. 694 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Getinfo PCMS:NAME=PCMS:0; GETREDSTAT PCMS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMS GETREDSTAT PCMS Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve information about the PCMSlines configured in duplex mode. It shows which is the active link. The validity range of the object address "pcmsn" can be found in Appendix A. System Responses: GETREDSTAT PCMS: NAME=PCMS:pcmsn; GETREDSTAT PCMS ACK:: Successful LKAPCM This attribute identifies which PCM link is active. Validity range: linkActivePcm linkA linkB LKSPCM This attribute represents the State of the link Validity range: linkStatePcm linkAandBOk linkAnotOk linkBnotOk bothNotOk LKCONFPCM This attribute represents the current bit selection. It is meaningful only for PCMS linesBinary values repre- senting the source of data in the PCM line. If the i-th bit is 0 then the i-th channel is receiving data from link A; other- wise from link B. Data will be shown as follows: 7-0 0011001015-8 ..... 127-120 .... GETREDSTAT PCMS NACK: NACK CAUSES: INVALID_COMMAND The syntax of the message received fromLMT is incorrect. OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 695 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution GetREDSTAT PCMS:NAME=PCMS:1; GETRELATIONSHIP PCMS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMS GETRELATIONSHIP PCMS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of all the HMOs (Hardware Managed Object) supporting the FMO functionality. For the PCMS object the related HMOs are the following: LICD/LICDS, EPWR, BSMS, TPWR, PWRD, MPCC, TDPC, MEMT and NTW. The validity range of the object address "pcmsn" can be found in Appendix A. System Responses: Application Guidelines: None. PCML_DISABLED_DEPENDENCY The line is disabled because LICD is unavailable so it can not be monitored. UNSUCCESSFUL_INVALID_ATTRIBUTES The line is congured as simplex. GETRELATIONSHIP PCMS: NAME=PCMS:pcmsn; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMOto HMOrelationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. 696 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Getrelationship PCMS:NAME=PCMS:0; GETSUBO PCMS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMS GETSUBO PCMS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "pcmsn" can be found in Appendix A. System Responses Application Guidelines: None. Example of Command Execution Getsubo PCMS:NAME=PCMS:0; LOCK PCMS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMS LOCK PCMS GETSUBO PCMS: NAME=PCMS:pcmsn; GETSUBO PCMS ACK: The output of the command can be composed by one or more pack with a maximumnumber of ten subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GET PCMS STATUS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK PCMS: NAME=PCMS:pcmsn; A30808-X3247-L230-3-7619 697 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "pcmsn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock PCMS:NAME=PCMS:0; SET PCMS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMS SET PCMS Applicability: Phase 2. Visibility level 2. Command Description: This command modifies the redundancy equipment of a PCM line on A sub interface. The parameter values must be equal to those in the TRAU data base. The validity range of the object address "pcmsn" can be found in Appendix A. LOCK PCMS ACK: LOCK PCMS NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SET PCMS: NAME=PCMS:pcmsn [,CRC=] [,LREDUNEQ=] [,BER=] [,LOWBER=] [,BAF=] [,CODE=] [,NUA=] [,REMAL=]; 698 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution For PCM30: Set PCMS:NAME=PCMS:0,CRC=FALSE,BAF=6,LREDUNEQ=DUPLEX, REMAL=CCITT,CODE=HDB3,NUA=FALSE,BER=E10_3,LOWBER=E10_3; For PCM24: Set PCMS:NAME=PCMS0:CRC=FALSE,LREDUNEQ=DUPLEX,BER=E10_3, LOWBER=E10_3; UNLOCK PCMS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMS UNLOCK PCMS SET ACK: Successful SET NACK: NACK CAUSES: OBJECT_NOTEQUIPPED The object instance must be already equipped. INVALID_COMMAND The LREDUNEQ attribute can be changed only from SIMPLEXA or SIMPLEXB to DUPLEX. No other changes are allowed. UNSUCCESSFUL_INVALID_STATUS When the attributes BAF and CRC4 are changed the PCMS must be in LOCKED state. Setting of CODE attribute is allowed only if the PCMS is in LOCKED status. UNSUCCESSFUL_INVALID_ATTRIBUTES The BAF attribute can be set only with the PCM30 lines (param- eter PCMTYPE of BSC object). The REMAL attribute can be set only with the PCM24 lines (PCMTYPE attribute of BSC object). The CODE and NUA attributes can be set only with the PCM30 lines (parameter PCMTYPE of BSC object). The value assigned to LOWBER attribute must be greater than or equal to the BER one. This means that the bit error rate for LOWBER is lower or equal than the BER one. For example LOWBER=3 (10-6 bit error rate), BER=2 (10-5 bit error rate). The LREDUNEQ attribute can be set at DUPLEX only if the WMOD attribute is set at DOUBLE_TRUNK. UNLOCK PCMS: NAME=PCMS:pcmsn; A30808-X3247-L230-3-7619 699 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "pcmsn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock PCMS:NAME=PCMS:0; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 700 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PCU The PCU functional object represents the packet control unit designed to implement GPRS service in SBS; depending on the BSC type PCU can be implemented by means of either PPCU (in case of standard BSC) or PPXU boards (in case of High Capacity BSC). In case of PPCU boards each PCU can handle 64 PDTs on A-bis interface with a maximum of 16 FRLs on Gb interface; in case of PPXU boards each PCU can handle 256 PDTs on A-bis interface with a maximum of 64 FRLs on Gb interface. CREATE PCU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCU CREATE PCU Applicability: Phase 2. Visibility level 2. Command Description: This command creates an instance of the PCU object class. The creation of the PCU object implies the consequent creation of: both PPCU cards (active and standby) if the NTWCARD is NTWSN16; one PPXU (with the same instance number of PCU) if the NTWCARD is either NTWSNAP or NTWSNAP_STLP. So it can be done only if the super-ordinate of PPCU/PPXU is created (EPWR) and, in case of the PPCUs, if the sum of time slots on internal 2 Mbit/s connection required for this unit is really free (PPLD not configured). If NTWCARD = NTWSN16 the system firstly creates the two PPCU objects, starting in Unlocked-Disabled/Not Initialized state, and then the PCU object, that is Locked- Disabled/Dependency/Not Initialized. When the first card will be Providing Service, then the PCU will start the configuration alignment. If NTWCARD = NTWSNAP or NTWSNAP_STLP, the system firstly creates one PPXU object, starting in Unlocked-Disabled/Not Initialized state, and then the PCU object, that is Locked-Disabled/Dependency/Not Initialized. When the card will be Providing Service, then the PCU will start the configuration alignment. CREATE PCU: NAME=PCU:pcun [,NMO=] ,NSEI= [,TNSVCBLK=] [,NNSVCBLKR=] [,NNSVCUBLR=] [,TNSVCR=] [,NNSVCRR=] [,TNSVCTST=] [,TNSVCPTST=] [,NNSVCTSTR=] [,NBVCBR=] [,NBVCUR=] [,NBVCRR=] [,T1=] [,T2=] [,TF1=] [,N3101=] [,N3103=] [,N3105=] [,NRLCMAX=] [,T3141=] [,T3169=] [,T3172=] [,T3191=] [,T3193=] [,T3195=] [,TEMPCH=] [,THPROXT=] [,THSULBAL=] [,TSULBAL=][,TIMEDTBFREL=] [,TEMPPDT=]; A30808-X3247-L230-3-7619 701 Commands Base Station Controller CML:BSC When NTWCARD=NTWSN16, note that: To create one PCU (PCU 0): delete PPLDs from 11 to 14 (if present); create PCU 0. This operation automatically creates the objects PPCU 0 and PPCU 1. To create two PCUs (PCU-0 and PCU-1): delete PPLDs from 11 to 14 (if present); create PCU 0; delete PPLDs from 7 to 10 (if present); create PCU 1. This operation automatically creates the objects PPCU 0, PPCU 1, PPCU 2 and PPCU 3. With NTWSN16, the PPCU boards are inserted in BSC rack in place of some PPLDs with the following correspondence: PPCU:0 in the empty slot corresponding to the unused PPLD:15; PPCU:1 in place of PPLD:12; PPCU:2 in place of PPLD:8; PPCU:3 in place of PPLD:9. When NTWCARD = NTWSNAP or NTWSNAP_STLP, the PPLD cannot be equipped, therefore each PCU can be created with the only precondition that one EPWR is created. To create one PCU (PCU 0): create PCU 0. This operation automatically creates the object PPXU 0. It must be noted that the PPXUs are 6. The PPXU boards are inserted in BSC rack in place of some PPLDs with the following correspondence: PPXU:0 in place of PPLD:4; PPXU:1 in place of PPLD:6; PPXU:2 in place of PPLD:8; PPXU:3 in place of PPLD: 9 PPXU:4 in place of PPLD:11; PPXU:5 in place of PPLD:13. The validity range of the object address "pcun" can be found in Appendix A. System Responses: CREATE ACK: Successful CREATE NACK: NACK CAUSES: OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The superordinate EPWR of PPCU or PPXU object instances must be already equipped. 702 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. All the attributes belonging to PCU object, with the exception of the following ones: NSEI; TNSVCBLK; NNSVCBLKR; NNSVCUBLR; TNSVCR; NNSVCRR; TNSVCTST; TNSVCPTST; NNSVCTSTR. must be set at the same value for all the PCUs present in the system. 2. In case of trouble on redundant NSVC links created on the Gb interface, it could happen that PTPPKF object is disabled while NSVCis still enabled. In order to avoid this situation the following rule has to be followed: TF1*number of ow control retries > TNSVCTST + TNSVCPTST*NNSVCTSTR. T_RESOURCE_CURRENTLY_BUSY The arrangement of the equipped PPLD does not allow the creation of the PCU object. The PPCU boards are inserted in BSC rack in place of some PPLD with the following correspondence (NTWSN16): PCU:0 in place of PPLD: 11, PPLD:12, PPLD:13, PPLD:14. PCU:1 in place of PPLD: 7, PPLD:8, PPLD:9, PPLD:10 The PPXU boards are inserted in BSC rack in place of some PPLD with the following correspondence (NTWSNAP or NTWSNAP_STLP): PPXU:0 in place of PPLD:4 PPXU:1 in place of PPLD:6 PPXU:2 in place of PPLD:8 PPXU:3 in place of PPLD:9 PPXU:4 in place of PPLD:11 PPXU:5 in place of PPLD:13 It is not allowed to have PCU, PCUTDand PPXT equipped with the same instance. UNSUCCESSFUL_INVALID_ATTRIBUTES Different PCU and PCUTD instance must have different NSEI values. The TEMPPDT attribute value must be lower than the TEMPCH attribute value. The arrangement of the equipped PCUTD or PPXT does not allow the creation of the PCU object. PCUTD or PPXT with the same instance are already created UNSUCCESSFUL_EXCEED_OBJECT_NBR The maximum number of PCUs per BSS is 2 if the network card is NTWSN16, 6 if the network card is NTWSNAP or NTWSNAP_STLP with old MPCC board, 12 if the network card is NTWSNAP_STLP with new MPCC board. UNSUCCESSFUL_VAR_OUT_RANGE The max number of PCUs has been reached; no other PCUs can be equipped. A30808-X3247-L230-3-7619 703 Commands Base Station Controller CML:BSC The number fo ow control retries is not manageable by operator and is xed to 15. Default values of all the above attributes are in according with the rule. 3. The NMO value must be the same for all PCUs; it is a task of the operator to guar- antee this condition. Example of Command Execution Create PCU:NAME=PCU:0,NMO=2,NSEI=40,TNSVCBLK=3,NNSVCBLKR=25, NNSVCUBLR=7,TNSVCR=6,NNSVCRR=32,TNSVCTST=20,TNSVCPTST=5, NNSVCTSTR=20,NBVCBR=12,NBVCUR=21,NBVCRR=14,T1=4,T2=6,TF1=50, N3101=32,N3103=23,N3105=23,NRLCMAX=25,T3141=24,T3169=4,T3172=10, T3191=9,T3193=4,T3195=20,TEMPCH=45,THPROXT=30-90-120, TIMEDTBFREL=15,TEMPPDT=15, THSULBAL =1000, TSULBAL = 50; DELETE PCU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCU DELETE PCU Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a previously created instance of the PCU object class. The PPCU/PPXU cards related to this PCU functionality will be implicitly deleted by the system. The validity range of the object address "pcun" can be found in Appendix A. System Responses: Application Guidelines: None. DELETE PCU: NAME=PCU:pcun; DELETE ACK: Successful DELETE NACK: NACK CAUSES: OBJECT_NOTEQUIPPED The object instance must be already equipped. SUBORDINATE_EQUIPPED All the FRL object instances associated to the PCU object instance must be previously deleted. If the PCU object instance is the last equipped in the BSC all PTPPKF object instances must be deleted. 704 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Delete PCU:NAME=PCU:0; A30808-X3247-L230-3-7619 705 Commands Base Station Controller CML:BSC GET PCU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCU GET PCU Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameter values of an instance of the PCUobject class. The validity range of the object address "pcun" can be found in Appendix A. System Responses: GET PCU: NAME=PCU:pcun [,REQATTL=NMO, NSEI, TNSVCBLK, NNSVCBLKR, NNSVCUBLR, TNSVCR, NNSVCRR, TNSVCTST, TNSVCPTST, NNSVCTSTR, NBVCBR, NBVCUR, NBVCRR, T1, T2, TF1, N3101, N3103, N3105, NRLCMAX, T3141, T3169, T3172, T3191, T3193, T3195, TEMPCH, THPROXT, TIMEDTBFREL, TEMPPDT, THSULBAL, TSULBAL]; GET ACK: NAME: name NMO: networkModeOf Operation NSEI: NetworkServiceElementIdentifier TNSVCBLK: timerInNsvcBlockProcedure NNSVCBLKR: numberOfNsvcBlockRetries NNSVCUBLR: numberOfNsvcUnblockRetries TNSVCR: timerNsvcReset NNSVCRR: numberOfNsvcResetRetries TNSVCTST: timerInNsvcTestProcedure TNSVCPTST: timerNsvcPeriodicTestProcedure NNSVCTSTR: NumberOfNsvcTestRetries NBVCBR: NumberOfBvcBlockRetries NBVCUR: NumberOfBvcUnblockRetries NBVCRR: NumberOfBvcResetRetries T1: t1 T2: t2 TF1: tf1 THSULBAL thresholdSwitchULBalanced TSULBAL timeSwitchULBalanced N3101: n3101 N3103: n3103 N3105 n3105 706 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get PCU:NAME=PCU:0,REQATTL=NMO&NSEI&TNSVCBLK&NNSVCBLKR& NNSVCUBLR&TNSVCR&NNSVCRR&TNSVCTST&TNSVCPTST&NNSVCTSTR& NBVCBR&NBVCUR&NBVCRR&T1&T2&TF1&N3101&N3103&N3105&NRLCMAX& T3141&T3169&T3172&T3191&T3193&T3195&TEMPCH&THPROXT& TIMEDTBFREL&TEMPPDT&THSULBAL&TSULBAL; GET PCU BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCU GET PCU BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "pcun" can be found in Appendix A. System Responses: NRLCMAX numberRlcMax T3141 t3141 T3169: t3169 T3172: t3172 T3191: t3191 T3193: t3193 T3195: t3195 TEMPCH: TimerEmptyChannel THPROXT: thresholdProximityTimer TIMEDTBFREL: timeDelayTBFRelease TEMPPDT: timerEmptyPDT GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET PCU BASICS: NAME=PCU:pcun; GET ACK: NAME: name NMO: networkModeOf Operation A30808-X3247-L230-3-7619 707 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get PCU BASICS:NAME=PCU:0; NSEI: NetworkServiceElementIdentifier TNSVCBLK: timerInNsvcBlockProcedure NNSVCBLKR: numberOfNsvcBlockRetries NNSVCUBLR: numberOfNsvcUnblockRetries TNSVCR: timerNsvcReset NNSVCRR: numberOfNsvcResetRetries TNSVCTST: timerInNsvcTestProcedure TNSVCPTST: timerNsvcPeriodicTestProcedure NNSVCTSTR: NumberOfNsvcTestRetries NBVCBR: NumberOfBvcBlockRetries NBVCUR: NumberOfBvcUnblockRetries NBVCRR: NumberOfBvcResetRetries T1: t1 T2: t2 TF1: tf1 THSULBAL thresholdSwitchULBalanced TSULBAL timeSwitchULBalanced N3101: n3101 N3103: n3103 N3105 n3105 NRLCMAX numberRlcMax T3141 t3141 T3169: t3169 T3172: t3172 T3191: t3191 T3193: t3193 T3195: t3195 TEMPCH: TimerEmptyChannel THPROXT: thresholdProximityTimer TIMEDTBFREL: timeDelayTBFRelease TEMPPDT: timerEmptyPDT GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 708 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET PCU STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCU GET PCU STAT Applicability: Phase 2. Visibility level 0. Command Description: This command ais used to retrieve the following State/Status attributes related to the PCU object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Unknown Status (UNK). The validity range of the object address "pcun" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get PCU STAT:NAME=PCU:0; GETINFO PCU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCU GETINFO PCU GET PCU STAT: NAME=PCU:pcun; GET PCU STAT ACK: GET PCU STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETINFO PCU: NAME=PCU:pcun; A30808-X3247-L230-3-7619 709 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The states and statuses of the PCU: AST, OST, AVS, CTS, STNDBY, PRS. 2. The Network Service Element Identier (NSEI) value. 3. For each PDT the following information: the internal timeslot number; the PTPPKF number; the BTSM number; the BTS number; the TRX number; the CHAN number; the type; the usage state; the resync counter. 4. For each FRL the following information: the FRL absolute number; the AST; the OST; the internal timeslot map; the speed; max 12 samples for the transmission load percentage; max 12 samples for the receiving load percentage; max 6 samples for the crc counter in the last 5 minutes; max 6 samples for the invalid counter in the last 5 minutes; max 6 samples for the invalid dlci counter in the last 5 minutes; the DLCI list. The validity range of the object address pcun can be found in Appendix A. System Responses: GETINFO PCU ACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** INFORMATION *** GETINFO REPORT PCU: NAME = PCU:0 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE STANDBY STATUS: PROVIDING_SERVICE i If the LMT is connected in remote mode, it is not possible to execute this command. 710 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PROCEDURAL STATUS: NONE NSEI: 12 PDT NR. INT.TSL NR. PTPPKF NR. BTSM NR. BTS NR. TRX NR. 0 0 0 0 0 0 ... ... ... ... ... ... ... ... ... ... ... ... 255 1 1 1 1 0 PDT NR. CHAN NR. TYPE USAGE RESYNC COUNT. 0 2 PCCCH IDLE 0 ... ... ... ... ... ... ... ... ... ... 255 6 PBCCH IDLE 0 FRL ABSOLUTE NR.: 7 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED INTERNAL TIMESLOT MAP: 66 67 SPEED: 192 KB/S TX LOAD %: 5 3 10 40 50 55 60 65 70 80 90 100 RX LOAD %: 30 CRC LAST 5 MIN: 5 3 10 2 1 3 INVALID LAST 5 MIN: 7 INVALID DLCI LAST 5 MIN: 11 DLCI LIST (MAX 32): 19 20 30 54 60 100 210 221 233 256 315 ... ... FRL ABSOLUTE NR.: 11 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED INTERNAL TIMESLOT MAP: 66 67 SPEED: 128 KB/S TX LOAD %: 10 20 30 35 40 45 50 55 60 70 80 RX LOAD %: 1 CRC LAST 5 MIN: 5 INVALID LAST 5 MIN: 2 5 1 2 5 1 INVALID DLCI LAST 5 MIN: 1 DLCI LIST (MAX 32): 71 END OF REPORT GETINFO PCU NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 A30808-X3247-L230-3-7619 711 Commands Base Station Controller CML:BSC *** RESPONSE TO JOB 1 *** Get Info Report Nack PCU: name = PCU:0 nackCause = <nack cause> Application Guidelines: None. Example of Command Execution Getinfo PCU:NAME=PCU:0; GETRELATIONSHIP PCU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCU GETRELATIONSHIP PCU Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of all the HMOs (Hardware Managed Object) supporting the FMO functionality. For the PCU object the related HMOs are the following: EPWR, PPCU, PWRD, MPCC, TDPC, MEMT, NTW and PPXU. The validity range of the object address "pcun" can be found in Appendix A. System Responses: NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. GETRELATIONSHIP PCU: NAME=PCU:pcun; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMOto HMOrelationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED 712 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Getrelationship PCU:NAME=PCU:0; GETSUBO PCU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCU GETSUBO PCU Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "pcun" can be found in Appendix A. System Responses Application Guidelines: None. Example of Command Execution Getsubo PCU:NAME=PCU:0; The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. GETSUBO PCU: NAME=PCU:pcun; GETSUBO ACK: The output of the command can be composed by one or more pack with a maximum number of three subordinated mnemonics; at the end there a message is displayed notifying the end of the subordi- nate list. GETSUBO NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 713 Commands Base Station Controller CML:BSC LOCK PCU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCU LOCK PCU Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state "Locked". The PCU object becomes DISABLED - Not initialized, while all the subordinated units shall be put in Disabled - Dependency/offline status: on one side the the PTPPKF, directly subordinated to PCU, and on the other the FRL and NSVC. This implies the activation of blocking procedure for NSVC objects towards SGSN. The appropriate system information informing MS about unavailability of the GPRS service in the cell, supported by the PCU, shall be sent. The command can cuase services interruption. The validity range of the object address "pcun" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock PCU:NAME=PCU:0; LOCK PCU: NAME=PCU:pcun; LOCK PCU ACK: LOCK PCU NACK: NACK CAUSES: INVALID_STATUS ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. 714 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SET PCU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCU SET PCU Applicability: Phase 2. Visibility level 2. Command Description: This command modifies the specific parameters of the PCU object class. To change NSEI and NMOparameters, the PCUmust be LOCKEDand the same check like create must be done. In this case the command is not forwarded to PCU because at unlock all the configuration is reloaded. To set the other attributes the PCU object could remain unlocked. The validity range of the object address "pcun" can be found in Appendix A. System Responses: Application Guidelines: 1. All the attributes belonging to PCU object, with the exception of the following ones: NSEI; TNSVCBLK; NNSVCBLKR; SET PCU: NAME=PCU:pcun [,NMO=] [,NSEI=] [,TNSVCBLK=] [,NNSVCBLKR=] [,NNSVCUBLR=] [,TNSVCR=] [,NNSVCRR=] [,TNSVCTST=] [,TNSVCPTST=] [,NNSVCTSTR=] [,NBVCBR=] [,NBVCUR=] [,NBVCRR=] [,T1=] [,T2=] [,TF1=] [,N3101=] [,N3103=] [,N3105=] [,NRLCMAX=] [,T3141=] [,T3169=] [,T3172=] [,T3191=] [,T3193=] [,T3195=] [,TEMPCH=] [,THPROXT=] [,THSULBAL=] [,TSULBAL=] [,TIMEDTBFREL=] [,TEMPPDT=]; SET ACK: Successful SET NACK: NACK CAUSES: OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The NSEI attribute can be set only if the PCU is in LOCKED state. UNSUCCESSFUL_INVALID_ATTRIBUTES Different PCU instances must have different NSEI values. The TEMPPDT attribute value must be lower than the TEMPCH attribute value. A30808-X3247-L230-3-7619 715 Commands Base Station Controller CML:BSC NNSVCUBLR; TNSVCR; NNSVCRR; TNSVCTST; TNSVCPTST; NNSVCTSTR. must be set at the same value for all the PCUs present in the system. 2. In case of trouble on redundant NSVC links created on the Gb interface, it could happen that PTPPKF object is disabled while NSVCis still enabled. In order to avoid this situation the following rule has to be followed: TF1*number of ow control retries > TNSVCTST + TNSVCPTST*NNSVCTSTR. The number fo ow control retries is not manageable by operator and is xed to 15. Default values of all the above attributes are in according with the rule. 3. The NMO value must be the same for all PCUs; it is a task of the operator to guar- antee this condition. Example of Command Execution Set PCU:NAME=PCU:0,NMO=2,NSEI=40,TNSVCBLK=3,NNSVCBLKR=25, NNSVCUBLR=7,TNSVCR=6,NNSVCRR=32,TNSVCTST=20,TNSVCPTST=5, NNSVCTSTR=20,NBVCBR=12,NBVCUR=21,NBVCRR=14,T1=4,T2=6,TF1=50, N3101=32,N3103=23,N3105=10,NRLCMAX=26,T3141=16,T3169=4,T3172=23, T3191=9,T3193=5,T3195=23,TEMPCH=45,THPROXT=30-90-120, TIMEDTBFREL=15,TEMPPDT=15, THSULBAL =1000, TSULBAL = 50; UNLOCK PCU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCU UNLOCK PCU Applicability: Phase 2. Visibility level 1. Command Description: This command removes the operator block and the unit is reloaded of configuration data: the operational state is Disabled - Not Initialized - Initializing. When the PCU will be enabled, the system information shall be sent on BCCH channel in order to inform all MS that the service is available in the cell supported by this PCU. The validity range of the object address "pcun" can be found in Appendix A. System Responses: UNLOCK PCU: NAME=PCU:pcun; UNLOCK ACK: Successful 716 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Unlock PCU:NAME=PCU:0; UNLOCK NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_STATUS A30808-X3247-L230-3-7619 717 Commands Base Station Controller CML:BSC PCUTD The PCUTD functional object represents the packet control unit designed to implement the TD-SCDMA packet switched service in SBS. The PCUTD is implemented by means of PPXP boards. CREATE PCUTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCUTD CREATE PCUTD Applicability: Phase 2. Visibility level 2. Command Description: This command creates an instance of the PCUTD object class. Due to the load balancing redundancy scheme, PCUTD is statically associated to the PPXP with the same instance: the creation of the instance x of PCUTD causes the automatic creation of the instance x of the related PPXP board. The system firstly creates one PPXP object, starting in Unlocked-Disabled/Not Initial- ized state, and then the PCUTD object, that is Locked-Disabled/Dependency/Not Initialized. When the card will be Providing Service, then the PCUTD will start the configuration alignment. Since PPXP cards are located into the expansion frame of the new rack together with PPXT and PPXU cards, the number of equipped/operating PPXP cards depends on the number of equipped PPXT and PPXU cards. The validity range of the object address "pcutdn" can be found in Appendix A. System Responses: CREATE PCUTD: NAME=PCUTD:pcutdn [,NMO=] ,NSEI= [,TNSVCBLK=] [,NNSVCBLKR=] [,NNSVCUBLR=] [,TNSVCR=] [,NNSVCRR=] [,TNSVCTST=] [,TNSVCPTST=] [,NNSVCTSTR=] [,NBVCBR=] [,NBVCUR=] [,NBVCRR=] [,T1=] [,T2=] [,TF1=] [,N3101TD=] [,N3103TD=] [,N3105TD=] [,NRLCMAXTD=] [,T3141TD=] [,T3169TD=] [,T3172TD=] [,T3191TD=] [,T3193TD=] [,T3195TD=] [,TEMPCHTD=] [,THPROXTD=] [,TIMEDTBFREL=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. 718 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. All the attributes belonging to PCUTD object, with the exception of the following ones: NSEI; TNSVCBLK; NNSVCBLKR; NNSVCUBLR; TNSVCR; NNSVCRR; TNSVCTST; TNSVCPTST; NNSVCTSTR. must be set at the same value for all the PCUTDs present in the system. 2. In case of trouble on redundant NSVC links created on the Gb interface, it could happen that PTPPKFTD object is disabled while NSVC is still enabled. In order to avoid this situation the following rule has to be followed: TF1*number of ow control retries > TNSVCTST + TNSVCPTST*NNSVCTSTR. The number fo ow control retries is not manageable by operator and is xed to 15. Default values of all the above attributes are in according with the rule. Example of Command Execution Create PCUTD:NAME=PCUTD:0,NMO=2,NSEI=40,TNSVCBLK=3,NNSVCBLKR=25, NNSVCUBLR=7,TNSVCR=6,NNSVCRR=32,TNSVCTST=20,TNSVCPTST=5, NNSVCTSTR=20,NBVCBR=12,NBVCUR=21,NBVCRR=14,T1=4,T2=6,TF1=50, N3101TD=32,N3103TD=23,N3105TD=23,NRLCMAXTD=25,T3141TD=24,T3169TD= 4,T3172TD=10,T3191TD=9,T3193TD=4,T3195TD=20,TEMPCHTD=45,THPROXTTD =30-90-120,TIMEDTBFREL=15; UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The superordinate EPWR must be already equipped. T_RESOURCE_CURRENTLY_BUSY The arrangement of the equipped PCU or PPXT does not allow the creation of the PCUTD object. PCU or PPXT with the same instance are already created. UNSUCCESSFUL_INVALID_ATTRIBUTES Different PCU and PCUTD instances must have different NSEI values. Feature supported only by new MPCC/TDPC. UNSUCCESSFUL_COMMAND_REJECTED A PCUTD creation is allowed only if the NTWCARD attribute of the BSC object is set to NTWSNAP_STLP. UNSUCCESSFUL_EXCEEDED_OBJECT_NBR The max number of PCUTDs has been reached; no other PCUTDs can be equipped. A30808-X3247-L230-3-7619 719 Commands Base Station Controller CML:BSC DELETE PCUTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCUTD DELETE PCUTD Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a previously created instance of the PCUTD object class. The PPXP card related to this PCUTD functionality will be implicitly deleted by the system. The validity range of the object address "pcutdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete PCUTD:NAME=PCUTD:0; DELETE PCUTD: NAME=PCUTD:pcutdn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: OBJECT_NOTEQUIPPED The object instance must be already equipped. SUBORDINATE_EQUIPPED All the FRL object instances associated to the PCUTD object instance must be previously deleted. If the PCUTD object instance is the last equipped in the BSC all PTPPKFTD object instances must be deleted. 720 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET PCUTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCUTD GET PCUTD Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameter values of an instance of the PCUTD object class. The validity range of the object address "pcutdn" can be found in Appendix A. System Responses: GET PCUTD: NAME=PCUTD:pcutdn [,REQATTL=NMO, NSEI, TNSVCBLK, NNSVCBLKR, NNSVCUBLR, TNSVCR, NNSVCRR, TNSVCTST, TNSVCPTST, NNSVCTSTR, NBVCBR, NBVCUR, NBVCRR, T1, T2, TF1, N3101TD, N3103TD, N3105TD, NRLCMAXTD, T3141TD, T3169TD, T3172TD, T3191TD, T3193TD, T3195TD, TEMPCHTD, THPROXTD, TIMEDTBFREL]; GET ACK: NAME: name NMO: networkModeOf Operation NSEI: NetworkServiceElementIdentifier TNSVCBLK: timerInNsvcBlockProcedure NNSVCBLKR: numberOfNsvcBlockRetries NNSVCUBLR: numberOfNsvcUnblockRetries TNSVCR: timerNsvcReset NNSVCRR: numberOfNsvcResetRetries TNSVCTST: timerInNsvcTestProcedure TNSVCPTST: timerNsvcPeriodicTestProcedure NNSVCTSTR: NumberOfNsvcTestRetries NBVCBR: NumberOfBvcBlockRetries NBVCUR: NumberOfBvcUnblockRetries NBVCRR: NumberOfBvcResetRetries T1: t1 T2: t2 TF1: tf1 N3101TD: n3101TD N3103TD: n3103TD N3105TD n3105TD NRLCMAXTD numberRlcMaxTD T3141TD t3141TD A30808-X3247-L230-3-7619 721 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get PCUTD:NAME=PCUTD:0,REQATTL=NMO&NSEI&TNSVCBLK&NNSVCBLKR& NNSVCUBLR&TNSVCR&NNSVCRR&TNSVCTST&TNSVCPTST&NNSVCTSTR& NBVCBR&NBVCUR&NBVCRR&T1&T2&TF1&N3101TD&N3103TD&N3105TD&NRL CMAXTD&T3141TD&T3169TD&T3172TD&T3191TD&T3193TD&T3195TD&TEMPCH TD&THPROXTTD&TIMEDTBFREL; GET PCUTD BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCUTD GET PCUTD BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "pcutdn" can be found in Appendix A. System Responses: T3169TD: t3169TD T3172TD: t3172TD T3191TD: t3191TD T3193TD: t3193TD T3195TD: t3195TD TEMPCHTD: TimerEmptyChannelTD THPROXTTD: thresholdProximityTimerTD TIMEDTBFREL: timeDelayTBFRelease GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET PCUTD BASICS: NAME=PCUTD:pcutdn; GET ACK: NAME: name NMO: networkModeOf Operation NSEI: NetworkServiceElementIdentifier TNSVCBLK: timerInNsvcBlockProcedure NNSVCBLKR: numberOfNsvcBlockRetries 722 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get PCUTD BASICS:NAME=PCUTD:0; NNSVCUBLR: numberOfNsvcUnblockRetries TNSVCR: timerNsvcReset NNSVCRR: numberOfNsvcResetRetries TNSVCTST: timerInNsvcTestProcedure TNSVCPTST: timerNsvcPeriodicTestProcedure NNSVCTSTR: NumberOfNsvcTestRetries NBVCBR: NumberOfBvcBlockRetries NBVCUR: NumberOfBvcUnblockRetries NBVCRR: NumberOfBvcResetRetries T1: t1 T2: t2 TF1: tf1 N3101TD: n3101TD N3103TD: n3103TD N3105TD n3105TD NRLCMAXTD numberRlcMaxTD T3141TD t3141TD T3169TD: t3169TD T3172TD: t3172TD T3191TD: t3191TD T3193TD: t3193TD T3195TD: t3195TD TEMPCHTD: TimerEmptyChannelTD THPROXTTD: thresholdProximityTimerTD TIMEDTBFREL: timeDelayTBFRelease GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 723 Commands Base Station Controller CML:BSC GET PCUTD STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCUTD GET PCUTD STAT Applicability: Phase 2. Visibility level 0. Command Description: This command ais used to retrieve the following State/Status attributes related to the PCUTD object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Unknown Status (UNK). The validity range of the object address "pcutdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get PCUTD STAT:NAME=PCUTD:0; GETINFO PCUTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCUTD GETINFO PCUTD GET PCUTD STAT: NAME=PCUTD:pcutdn; GET PCUTD STAT ACK: GET PCUTD STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETINFO PCUTD: NAME=PCUTD:pcutdn; 724 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The states and statuses of the PCUTD: AST, OST, AVS, CTS, STNDBY, PRS. 2. The Network Service Element Identier (NSEI) value. 3. For each PDT the following information: the internal timeslot number; the BVCI number; the BTSMTD number; the BTSTD number; the TRXTD number; the Uplink AIRTSTD; the Uplink Virtual Resource Unit; the Downlink AIRTSTD; the Downlink Virtual Resource Unit; the type; the usage state; the resync counter. 4. For each FRL the following information: the FRL absolute number; the AST; the OST; the internal timeslot map; the speed; max 12 samples for the transmission load percentage; max 12 samples for the receiving load percentage; max 6 samples for the crc counter in the last 5 minutes; max 6 samples for the invalid counter in the last 5 minutes; max 6 samples for the invalid dlci counter in the last 5 minutes; the DLCI list. The validity range of the object address pcutdn can be found in Appendix A. System Responses: GETINFO PCUTD ACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** INFORMATION *** GETINFO REPORT PCUTD: NAME = PCUTD:0 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED i If the LMT is connected in remote mode, it is not possible to execute this command. A30808-X3247-L230-3-7619 725 Commands Base Station Controller CML:BSC AVAILABILITY STATUS: NONE CONTROL STATUS: NONE STANDBY STATUS: PROVIDING_SERVICE PROCEDURAL STATUS: NONE NSEI: 12 PDT NR. INT.TSL NR. BVCI NR. BTSMTD NR. BTSTD NR. TRXTD NR. 0 0 0 0 0 0 255 1 1 1 1 0 PDT NR. ULTS NR. ULVRU DLTS DLVRU TYPE USAGE 0 0 15 0 0 PDTCH IDLE 255 6 0 6 15 PBCCH IDLE PDT NR. RESYNC COUNT. 0 0 255 0 FRL ABSOLUTE NR.: 7 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED INTERNAL TIMESLOT MAP: 66 67 SPEED: 192 KB/S TX LOAD %: 5 3 10 40 50 55 60 65 70 80 90 100 RX LOAD %: 30 CRC LAST 5 MIN: 5 3 10 2 1 3 INVALID LAST 5 MIN: 7 INVALID DLCI LAST 5 MIN: 11 DLCI LIST (MAX 32): 19 20 30 54 60 100 210 221 233 256 315 ... ... FRL ABSOLUTE NR.: 11 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED INTERNAL TIMESLOT MAP: 66 67 SPEED: 128 KB/S TX LOAD %: 10 20 30 35 40 45 50 80 80 90 100 RX LOAD %: 1 CRC LAST 5 MIN: 5 INVALID LAST 5 MIN: 2 5 1 2 5 1 INVALID DLCI LAST 5 MIN: 1 726 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DLCI LIST (MAX 32): 71 END OF REPORT GETINFO PCUTD NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack PCUTD: name = PCUTD:0 nackCause = <nack cause> Application Guidelines: None. Example of Command Execution Getinfo PCUTD:NAME=PCUTD:0; GETRELATIONSHIP PCUTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCUTD GETRELATIONSHIP PCUTD Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of all the HMOs (Hardware Managed Object) supporting the FMO functionality. For the PCUTD object the related HMOs are the following: PWRD, MPCC, TDPC, MEMT, NTW and PPXP. The validity range of the object address "pcutdn" can be found in Appendix A. NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. GETRELATIONSHIP PCUTD: NAME=PCUTD:pcutdn; A30808-X3247-L230-3-7619 727 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Getrelationship PCUTD:NAME=PCUTD:0; GETSUBO PCUTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCUTD GETSUBO PCUTD Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "pcutdn" can be found in Appendix A. System Responses Application Guidelines: None. GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMOto HMOrelationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. GETSUBO PCUTD: NAME=PCUTD:pcutdn; GETSUBO ACK: The output of the command can be composed by one or more pack with a maximum number of three subordinated mnemonics; at the end there a message is displayed notifying the end of the subordi- nate list. GETSUBO NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 728 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Getsubo PCUTD:NAME=PCUTD:0; A30808-X3247-L230-3-7619 729 Commands Base Station Controller CML:BSC LOCK PCUTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCUTD LOCK PCUTD Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state "Locked". The PCUTDobject becomes DISABLED- Not initialized, while all the subordinated units shall be put in Disabled - Dependency/offline status: on one side the PTPPKFTD, directly subordinated to PCUTD, and on the other the FRL and NSVC. This implies the activation of blocking procedure for NSVC objects towards SGSN. The appropriate system information informing MS about unavailability of the GPRS service in the cell, supported by the PCUTD, shall be sent. The command can cuase services interruption. The validity range of the object address "pcutdn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock PCUTD:NAME=PCUTD:0; LOCK PCUTD: NAME=PCUTD:pcutdn; LOCK PCUTD ACK: LOCK PCUTD NACK: NACK CAUSES: INVALID_STATUS ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. 730 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SET PCUTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCUTD SET PCUTD Applicability: Phase 2. Visibility level 2. Command Description: This command modifies the specific parameters of the PCUTD object class. To change NSEI and NMO parameters, the PCUTD must be LOCKED and the same check like create must be done. In this case the command is not forwarded to PCUTD because at unlock all the configuration is reloaded. To set the other attributes the PCUTD object could remain unlocked. The validity range of the object address "pcutdn" can be found in Appendix A. System Responses: Application Guidelines: 1. All the attributes belonging to PCUTD object, with the exception of the following ones: NSEI; TNSVCBLK; NNSVCBLKR; NNSVCUBLR; SET PCUTD: NAME=PCUTD:pcutdn [,NMO=] [,NSEI=] [,TNSVCBLK=] [,NNSVCBLKR=] [,NNSVCUBLR=] [,TNSVCR=] [,NNSVCRR=] [,TNSVCTST=] [,TNSVCPTST=] [,NNSVCTSTR=] [,NBVCBR=] [,NBVCUR=] [,NBVCRR=] [,T1=] [,T2=] [,TF1=] [,N3101TD=] [,N3103TD=] [,N3105TD=] [,NRLCMAXTD=] [,T3141TD=] [,T3169TD=] [,T3172TD=] [,T3191TD=] [,T3193TD=] [,T3195TD=] [,TEMPCHTD=] [,THPROXTD=] [,TIMEDTBFREL=]; SET ACK: Successful SET NACK: NACK CAUSES: OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The NSEI attribute can be set only if the PCUTD is in LOCKED state. UNSUCCESSFUL_INVALID_ATTRIBUTES Different PCU and PCUTD instances must have different NSEI values. A30808-X3247-L230-3-7619 731 Commands Base Station Controller CML:BSC TNSVCR; NNSVCRR; TNSVCTST; TNSVCPTST; NNSVCTSTR. must be set at the same value for all the PCUTDs present in the system. 2. In case of trouble on redundant NSVC links created on the Gb interface, it could happen that PTPPKFTD object is disabled while NSVC is still enabled. In order to avoid this situation the following rule has to be followed: TF1*number of ow control retries > TNSVCTST + TNSVCPTST*NNSVCTSTR. The number fo ow control retries is not manageable by operator and is xed to 15. Default values of all the above attributes are in according with the rule. Example of Command Execution Set PCUTD:NAME=PCUTD:0,NMO=2,NSEI=40,TNSVCBLK=3,NNSVCBLKR=25, NNSVCUBLR=7,TNSVCR=6,NNSVCRR=32,TNSVCTST=20,TNSVCPTST=5, NNSVCTSTR=20,NBVCBR=12,NBVCUR=21,NBVCRR=14,T1=4,T2=6,TF1=50, N3101TD=32,N3103TD=23,N3105TD=10,NRLCMAXTD=26,T3141TD=16,T3169TD= 4,T3172TD=23,T3191TD=9,T3193TD=5,T3195TD=23,TEMPCHTD=45,THPROXTTD =30-90-120,TIMEDTBFREL=15; UNLOCK PCUTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCUTD UNLOCK PCUTD Applicability: Phase 2. Visibility level 1. Command Description: This command removes the operator block and the unit is reloaded of configuration data: the operational state is Disabled - Not Initialized - Initializing. When the PCUTD will be enabled, the system information shall be sent on BCCH channel in order to informall MS that the service is available in the cell supported by this PCTDU. The validity range of the object address "pcutdn" can be found in Appendix A. System Responses: UNLOCK PCUTD: NAME=PCUTD:pcutdn; UNLOCK ACK: Successful UNLOCK NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_STATUS 732 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Unlock PCUTD:NAME=PCUTD:0; A30808-X3247-L230-3-7619 733 Commands Base Station Controller CML:BSC PPCC The PPCC object represents the peripheral processor that handles the level 2 of the CCS/ for four channels at 64 kbit/s from/to MSC. GET PPCC STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPCC GET PPCC STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the PPCC object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Unknown Status (UNK). The validity range of the object address "ppccn" can be found in Appendix A. System Responses: Application Guidelines: Only sets with raised bits are shown. Example of Command Execution Get PPCC STAT:NAME=PPCC:0; GET PPCC STAT: NAME=PPCC:ppccn; GET PPCC STAT ACK: GET PPCC STAT NACK: NACK CAUSES: None. 734 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETINFO PPCC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPCC GETINFO PPCC Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The RSU running object and the RSU version. 2. The states and statuses of the PPCC: AST, OST, AVS, STNDBYST, PRS. 3. The software state inside the board; the available are: INSERVICE, OOS_IDLE, OOS_FAULT, START_REQUIRED and LOAD_REQUIRED. 4. For each SS7 link handled by the PPCC: the SS7 number, the states and statuses of the link and the PCMS timeslot. The validity range of the object address ppccn can be found in Appendix A. System Responses: GETINFO PPCC ACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** INFORMATION *** GETINFO REPORT PPCC: NAME = PPCC:0 RSU RUNNING: RSUEXE 0-1 RSU VERSION: 02-06-01-01-00-00_00-01-10 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE STANDBY STATUS: NONE PROCEDURAL STATUS: NONE SOFTWARE STATE: IN_SERVICE SS7L 0: ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE GETINFO PPCC: NAME=PPCC:ppccn; A30808-X3247-L230-3-7619 735 Commands Base Station Controller CML:BSC STANDBY STATUS: NONE PROCEDURAL STATUS: NONE SS7L ASUB TIMESLOT: 0 - 3 (PCM NR - TS NR) ... ... SS7L 3: ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE STANDBY STATUS: NONE PROCEDURAL STATUS: NONE SS7L ASUB TIMESLOT: 0 - 16 (PCM NR - TS NR) END OF REPORT GETINFO PPCC NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack PPCC: name = PPCC:0 nackCause = <nack cause> Application Guidelines: Only equipped SS7 links should be displayed. Example of Command Execution Getinfo PPCC:NAME=PPCC:0; NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. 736 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETRELATIONSHIP PPCC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPCC GETRELATIONSHIP PPCC Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected HMO (Hardware Managed Object); the relationship information consist of all the FMOs (Functional Managed Object) using the HMO service. This information is included in the RELATED_FUNCTIONAL_OBJECTS attribute (ATTID parameter) and the attribute value depends on the working state of the target HMO. For the PPCC object the SS7L is the related FMO. The validity range of the object address "ppccn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship PPCC:NAME=PPCC:0,ATTID=RELATED_FUNCTIONAL_OBJECTS; GETSUBO PPCC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPCC GETSUBO PPCC GETRELATIONSHIP PPCC: NAME=PPCC:ppccn,ATTID=; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected HMO the list of related FMOs is displayed (HMO to FMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_ATTRIBUTES The object instance does not provide any relationship attribute. GETSUBO PPCC: NAME=PPCC:ppccn; A30808-X3247-L230-3-7619 737 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "ppccn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo PPCC:NAME=PPCC:0; GETTEST PPCC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPCC GETTEST PPCC Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the values of all the attributes belonging to a specified test object; the test object is created by the systemas a result of a request to start a test and it is deleted when the test terminates. The validity range of the object address "ppccn" can be found in Appendix A. System Responses: GETSUBO PPCC ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GETSUBO PPCC NACK: NACK CAUSES: None. GETTEST PPCC: NAME=PPCC:ppccn; GETTEST PPCC ACK: GETTEST PPCC:NAME=PPCC:0; name = TEST:<n> 738 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Gettest PPCC:NAME=PPCC:0; LOCK PPCC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPCC LOCK PPCC Applicability: Phase 2. Visibility level 1. Command Description: This command allows to force an object to the administrative state "Locked". The validity range of the object address "ppccn" can be found in Appendix A. mOts = PPCC:0 testState = It can assume one of the following values: not_initialized, idle, initializing, suspended, testing, terminating and disabled. testOutcome = It represents the test result: it can be Inconclusive (meaning-less: that is if the phases already executed were successful) or Fail (if at least one of the executed phases failed). testMonitor phaseId = It is a list of the phases to execute and their status that can be: pass, fail, running or waiting. phaseStatus = phaseId = phaseStatus = .... GETTEST PPCC NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. LOCK PPCC: NAME=PPCC:ppccn; A30808-X3247-L230-3-7619 739 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock PPCC:NAME=PPCC:0; PERFTEST PPCC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPCC PERFTEST PPCC Applicability: Phase 2. Visibility level 2. Command Description: This command is used to perform a test on the selected PPCC object; the test consist of the following phases: Preliminary Tests (start phase), Memory Test (WP1), LCS7 Test (WP2), Loopback Test (WP3), R/W Loopback Register Test (WP4), Force Alarm Test (WP5), Alarm Test - TDPC Side (WP6), End Test (end phase). The validity range of the object address "ppccn" can be found in Appendix A. System Responses: LOCK PPCC ACK: LOCK PPCC NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. PERFTEST PPCC: NAME=PPCC:ppccn; PERFTEST PPCC ACK: PERFTEST PPCC:NAME=PPCC:0; testObject=TEST:<n> 740 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked" state, if the diagnostic is intrusive. 2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for test" state. When the test result is: "fail" the object goes in Disabled / Failed operational state; "pass" the object goes in Enabled operational state; The test results will be displayed at the end of the test phases. Result TEST: name = TEST:<n> testOutcome = This field represents the test result; one of the following values can be displayed: Pass all the test phases are successfully performed. Inconclusive the test is aborted by the system or the test is terminated by the operator. Fail if at least one of the executed phases fail. mOts = It is the identifier of the hardware object under test. testTermination = It specifies how the test is terminated, it can assume the following values: Normal all the test phases are performed. Abort the test is aborted by system. Cancel the test is terminated by operator. executedPhases phaseId = It represents the list of the executed test phases (in case of successful test result, all the test phases will be listed). additionalWords = .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases; they are displayed only for test stopped during it execution. phaseId = .... poprosedRepair Action = A list of most probable fail probable causes is shown (max four messages) PERFTEST PPCC NACK: NACK CAUSES: MOTS_NOT_LOCKED The selected object is not in LOCKED administrative state. OTHER_TESTS_RUNNING Other incompatible tests are already running or no more parallel execution of tests are possible. A30808-X3247-L230-3-7619 741 Commands Base Station Controller CML:BSC "inconclusive" the object returns to the operational state previous to the test or in Enabled operational state. Example of Command Execution Perftest PPCC:NAME=PPCC:0; STOPTEST PPCC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPCC STOPTEST PPCC Applicability: Phase 2. Visibility level 2. Command Description: This command allows to terminate the test previously requested; the test can be in progress or in the waiting list (queued). In the first case the process that execute the diagnostic will be interrupted by executing the end phase; in the second case the test will be removed from the waiting list. The validity range of the object address "ppccn" can be found in Appendix A. System Responses: STOPTEST PPCC: NAME=PPCC:ppccn; STOPTEST PPCC ACK: STOPTEST PPCC:NAME=PPCC:0; testObject=TEST:<n> Result TEST: name = TEST:<n> testOutcome = inconclusive mOts = PPCC:0 testTermination = Cancel executedPhases phaseId = It represents the list of the executed test phases; the list is not shown for test in the waiting list (queued). .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases;the list is not shown for test in the waiting list (queued). phaseId = .... STOPTEST PPCC NACK: 742 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Stoptest PPCC:NAME=PPCC:0; UNLOCK PPCC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPCC UNLOCK PPCC Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". System Responses: Application Guidelines: It is possible to unlock the PPCC card with the status in LOCKED and UNDER TEST. Example of Command Execution UNLOCK PPCC:NAME=PPCC:0; NACK CAUSES: NO_SUCH_TEST The test is not active. UNABLE_TO_STOP_TEST The test can not be stopped. UNLOCK PPCC: NAME=PPCC:ppccn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. A30808-X3247-L230-3-7619 743 Commands Base Station Controller CML:BSC PPCU The PPCU equipment object represent the new card designed to implement the PCU unit; each card is able to handle maximum 2 Mbit/s of data transmission split in two parts: A-bis and Gb interface. These objects are automatically created by means of the CREATE PCU command and therefore no command for creating PPCU exist. GET PPCU STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT PPCU GET PPCU STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the PPCU object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Standby Status (STNDBY) Unknown Status (UNK). The validity range of the object address "ppcun" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get PPCU STAT:NAME=PPCU:0; GET PPCU STAT: NAME=PPCU:ppcun; GET PPCU STAT ACK: GET PPCU STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. 744 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETINFO PPCU Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT PPCU GETINFO PPCU Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The RSU running object and the RSU version. 2. The rmware version. 3. The states and statuses of the PPCU: AST, OST, AVS, CTS, STNDBY, PRS. 4. The software state inside the board; the available are: INSERVICE, OOS_IDLE, OOS_FAULT, START_REQUIRED and LOAD_REQUIRED. 5. The operational data of the GBIC Controller: real time, current OS time, all dynamic memory pool type (the used and total buffer numbers) and the total and largest block available. 6. The operational data of the PCUC processor: real time, current OS time, OS time of last Task init, type and OS time of the last exception, number of task init from last bring-up, number of exceptions since last Bring-up init and number of exceptions since last Task init, all dynamic memory pool type (the used and total buffer numbers from pool 0 to pool 9) and the total and largest block available. The validity range of the object address ppcun can be found in Appendix A. System Responses: GETINFO PPCU ACK: BSC_CONTROLLER -> LMT_LOCAL 11:41:14 22/03/1999 *** INFORMATION *** GET INFO REPORT PPCU: NAME = PPCU:0 RSU RUNNING: RSUEXE 2-1 RSU VERSION: 02-06-01-01-00-00_00-01-10 FW VERSION: sbs-fv-2-1-06-00 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE STANDBY STATUS: PROVIDING_SERVICE PROCEDURAL STATUS: NONE GETINFO PPCU: NAME=PPCU:ppcun; A30808-X3247-L230-3-7619 745 Commands Base Station Controller CML:BSC SOFTWARE STATE: OUT_OF_SERVICE_IDLE GBIC CONTROLLER: REAL TIME LOAD: 31% CURRENT OS TIME: 0049:05:54 DYNAMIC MEMORY USAGE: 0:0017/0500 1:0507/1000 2:0109/0640 3:0102/0300 4:0017/0300 5:0000/0100 6:0000/0200 7:0001/1000 8:0002/0200 9:0000/0500 TOTAL AND LARGEST BLOCK AVAILABLE: 00000001/02234400 PCUC PROCESSOR: REAL TIME LOAD: 31% CURRENT OS TIME: 0049:05:54 OS TIME OF LAST TASK INIT: 0000:00:00 OS TIME OF LAST EXCEPTION: 0000:00:00 TYPE OF LAST EXCEPTION: 244 NUMBER OF TASK INIT SINCE LAST BRING-UP: 0001 NUMBER OF EXCEPTION SINCE LAST BRING-UP INIT: 0000 NUMBER OF EXCEPTION SINCE LAST TASK INIT: 0000 DYNAMIC MEMORY USAGE: 0:0017/0031 1:0057/1000 2:0109/0640 3:0109/0300 4:0017/0200 5:0000/0150 6:0000/0100 7:0001/1000 8:0001/0300 9:0000/0050 A:0000/0150 B:0000/0100 TOTAL AND LARGEST BLOCK AVAILABLE: 00000001/02234400 END OF REPORT GETINFO PPCU NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack PPCU: name = PPCU:0 nackCause = <nack cause> Note: Only equipped SS7 should be displayed. NACK CAUSES:: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. 746 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: Only equipped SS7 links should be displayed. Example of Command Execution Getinfo PPCU:NAME=PPCU:0; GETRELATIONSHIP PPCU Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCEPPCU GETRELATIONSHIP PPCU Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected HMO (Hardware Managed Object); the relationship information consist of the all FMOs (Functional Managed Object) using the HMO service. This information is included in the RELATED_FUNCTIONAL_OBJECTS attribute (ATTID parameter) and the attribute value depends on the working state of the target HMO. For the PPCU object the PCU is the related FMO. The validity range of the object address "ppcun" can be found in Appendix A. System Responses: Application Guidelines: None. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo of the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. GETRELATIONSHIP PPCU: NAME=PPCU:ppcun,ATTID=; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected HMO the list of related FMOs is displayed (HMO to FMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_ATTRIBUTES The object instance does not provide any relationship attribute. A30808-X3247-L230-3-7619 747 Commands Base Station Controller CML:BSC Example of Command Execution Getrelationship PPCU:NAME=PPCU:0,ATTID=RELATED_FUNCTIONAL_OBJECTS; GETSUBO PPCU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC PPCU GETSUBO PPCU Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "ppcun" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo PPCU:NAME=PPCU:0; GETTEST PPCU Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPCU GETTEST PPCU GETSUBO PPCU: NAME=PPCU:ppcun; GETSUBO ACK: The output of the command can be composed by one or more pack with a maximumnumber of three subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GET PPCU STATUS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. GETTEST PPCU: NAME=PPCU:ppcun; 748 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the values of all the attributes belonging to a specified test object; the test object is created by the systemas a result of a request to start a test and it is deleted when the test terminates. The validity range of the object address "ppcun" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Gettest PPCU:NAME=PPCU:0; GETTEST PPCU ACK: GETTEST PPCU:NAME=PPCU:0; name = TEST:<n> mOts = PPCU:0 testState = It can assume one of the following values: not_initialized, idle, initializing, suspended, testing, terminating and disabled. testOutcome = It represents the test result: it can be Inconclusive (meaning-less: that is if the phases already executed were successful) or Fail (if at least one of the executed phases failed). testMonitor phaseId = It is a list of the phases to execute and their status that can be: pass, fail, running or waiting. phaseStatus = phaseId = phaseStatus = .... GETTEST PPCU NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. A30808-X3247-L230-3-7619 749 Commands Base Station Controller CML:BSC LOCK PPCU Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT PPCU LOCK PPCU Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The command related to the Providing Service copy, causes the switch between the PPCU copies; the command related to the Standby copy causes only state transition without affecting service. The command execution induces board resetting. Therefore involved card becomes Disabled / Locked / Not Initialized. The only exception is represented by Lock command during a SWLoad in progress: in this circumstance the card is not reset and load goes on.This command will cause services interruption if it is related to the PPCU Providing Service and the PPCU Standby copy is not Enabled / Unlocked / Cold-Standby. The validity range of the object address "ppcun" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock PPCU:NAME=PPCU:0; LOCK PPCU: NAME=PPCU:ppcun; LOCK PPCU ACK: Successful LOCK PPCU NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. 750 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PERFTEST PPCU Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPCU PERFTEST PPCU Applicability: Phase 2. Visibility level 2. Command Description: This command is used to perform a test on the selected PPCU object; the test consist of the following phases: Preliminary Tests (start phase), MPCC and TDPC DUAM Test (WP1), ABIC Test (WP2), GBIC SW Test (WP3), End Test (end phase). The validity range of the object address "ppcun" can be found in Appendix A. System Responses: PERFTEST PPCU: NAME=PPCU:ppcun; PERFTEST PPCU ACK: PERFTEST PPCU:NAME=PPCU:0; testObject=TEST:<n> The test results will be displayed at the end of the test phases. Result TEST: name = TEST:<n> testOutcome = This field represents the test result; one of the following values can be displayed: Pass all the test phases are successfully performed. Inconclusive the test is aborted by the system or the test is terminated by the operator. Fail if at least one of the executed phases fail. mOts = It is the identifier of the hardware object under test. testTermination = It specifies how the test is terminated, it can assume the following values: Normal all the test phases are performed. Abort the test is aborted by system. Cancel the test is terminated by operator. executedPhases phaseId = It represents the list of the executed test phases (in case of successful test result, all the test phases will be listed). additionalWords = .... A30808-X3247-L230-3-7619 751 Commands Base Station Controller CML:BSC Application Guidelines: 1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked" state, if the diagnostic is intrusive. 2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for test" state. When the test result is: "fail" the object goes in Disabled / Failed operational state; "pass" the object goes in Enabled operational state; "inconclusive" the object returns to the operational state previous to the test or in Enabled operational state. Example of Command Execution Perftest PPCU:NAME=PPCU:0; STOPTEST PPCU Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPCU STOPTEST PPCU Applicability: Phase 2. Visibility level 2. Command Description: This command allows to terminate the test previously requested; the test can be in progress or in the waiting list (queued). In the first case the process that execute the diagnostic will be interrupted by executing failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases; they are displayed only for test stopped during it execution. phaseId = .... poprosedRepair Action = A list of most probable fail probable causes is shown (max four messages) PERFTEST PPCU NACK: NACK CAUSES: MOTS_NOT_LOCKED The selected object is not in LOCKED administrative state. OTHER_TESTS_RUNNING Other incompatible tests are already running or no more parallel execution of tests are possible. STOPTEST PPCU: NAME=PPCU:ppcun; 752 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller the end phase; in the second case the test will be removed from the waiting list. The validity range of the object address "ppcun" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Stoptest PPCU:NAME=PPCU:0; SWITCH PPCU Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT PPCU SWITCH PPCU Applicability: Phase 2. STOPTEST PPCU ACK: STOPTEST PPCU:NAME=PPCU:0; testObject=TEST:<n> Result TEST: name = TEST:<n> testOutcome = inconclusive mOts = PPCU:0 testTermination = Cancel executedPhases phaseId = It represents the list of the executed test phases; the list is not shown for test in the waiting list (queued). .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases;the list is not shown for test in the waiting list (queued). phaseId = .... STOPTEST PPCU NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNABLE_TO_STOP_TEST The test can not be stopped. SWITCH PPCU: NAME=PPCU:ppcun; A30808-X3247-L230-3-7619 753 Commands Base Station Controller CML:BSC Visibility level 1. Command Description: This command can be accepted only if the configuration is one copy UnLocked, Enabled, Providing Service and the opposite on UnLocked, Enabled, Cold-Standby and causes the switch between the PPCU copies. In the standby copy it causes only state transition but the subordinated PCU object is reset and becames DISABLED- Not Initialized/initializing (all GPRS traffic is interrupted if any). The validity range of the object address "ppcun" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Switch PPCU:NAME=PPCU:0; UNLOCK PPCU Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT PPCU UNLOCK PPCU Applicability: Phase 2. Visibility level 1. Command Description: This command removes the operator block and the unit remains in the operational state as it is at the moment of the command. From Disabled/Not Initialized, the unit, whose loading procedure is going on, transits in Enable state. The validity range of the object address "ppcun" can be found in Appendix A. System Responses: SWITCH ACK: Successful SWITCH NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_STATUS UNLOCK PPCU: NAME=PPCU:ppcun; UNLOCK ACK: Successful 754 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: It is possible to unlock the PPCU card with the status in LOCKED and UNDER TEST. Example of Command Execution Unlock PPCU:NAME=PPCU:0; UNLOCK NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_STATUS A30808-X3247-L230-3-7619 755 Commands Base Station Controller CML:BSC PPLD The PPLD object represents the LAPD processing for eight channels from/to TRAU (at 64 kbit/s) or BTS (at 16kbit/s or 64 kbit/s); it interfaces both copies of the TDPC through the Dual Port RAM. CREATE PPLD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPLD CREATE PPLD Applicability: Phase 2. Visibility level 2. Command Description: This command adds a PPLD card to the system. Each card supports the level 2 of the LAPD protocol; the LAPD link can be configured at 64 kbit/s or 16 kbit/s. The LAPD link can be for BTSM (LPDLM), TRX (LPDLR), TRAU (LPDLS); the PPLD card has the following restriction about the managing of these different links: The validity range of the object address "ppldn" can be found in Appendix A. System Responses: CREATE PPLD: NAME=PPLD:ppldn; PDLM number + LPDLS number <= 8 PDLM number + LPDLS number + LPDLR number <= 64 CREATE ACK: Successful LOAD IN PROGRESS: SFWR Processor Type: PPLD Processor: 2 Directory: SYS_BACKUP N.E Software Version: 01-00-01-01-04-04_95-03-01 File Software Version: 01-00-01-01-04-04_95-03-01 CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. 756 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The relevant hardware has to be plugged in the corresponding slot before submitting the command. 2. After the creation of the object, the ADMINISTRATIVE state of this object is set to UNLOCKED. The UNLOCK command is NOT required to put this object in service. 3. The system can support LAPD Links only after the creation of two PPLD cards at least. One PPLD is available to the system whilst the other is a physical spare. Example of Command Execution Create PPLD:NAME=PPLD:2; DELETE PPLD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPLD DELETE PPLD Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a PPLD card previously created through the CREATE PPLD command. The validity range of the object address "ppldn" can be found in Appendix A. System Responses: UNSUCCESSFUL_COMMAND_REJECTED No PPLD instance can be created if the network card is NTWSNAP or NTWSNAP_STLP. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED If the object instance number is greater than 2, the EPWR object instance must be already equipped. DELETE PPLD: NAME=PPLD:ppldn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_VAR_OUT_OF_RANGE If the NTWCARD is set at NTWSN16, the number of different LAPDPOOLs must not exceed the number of equipped PPLDs available (excluding the PPLD spare). A30808-X3247-L230-3-7619 757 Commands Base Station Controller CML:BSC Application Guidelines: The relevant hardware can be unplugged after submitting the command. Example of Command Execution Delete PPLD:NAME=PPLD:2; GET PPLD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPLD GET PPLD Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the EQUIPPED state of the PPLD card. The validity range of the object address "ppldn" can be found in Appendix A. System Responses: Application Guidelines: None. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED A PPLD can not be created when NTWCARD = NTWSNAP (BSC object). UNSUCCESSFUL_INVALID_STATUS Before deleting a PPLD, the relative object instance must be in LOCKED state. UNSUCCESSFUL_IN_TEST The command is rejected if a diagnostic test is running on the PPLD card. UNSUCCESSFUL_SUBORDINATE_EQUIPPED The object must not have subordinate equipped (there must be a logical ppld (see CREATE PPLD command) with all free circuits, in addition to a spare ppld). GET PPLD NAME=PPLD:ppldn; GET ACK: NAME: name GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. 758 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Get PPLD:NAME=PPLD:0; GET PPLD STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPLD GET PPLD STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the PPLD object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Standby Status (STNDBY) Unknown Status (UNK). The validity range of the object address "ppldn" can be found in Appendix A. System Responses: Application Guidelines: Only sets with raised bits are shown. Example of Command Execution Get PPLD STAT:NAME=PPLD:0; GET PPLD STAT: NAME=PPLD:ppldn; GET PPLD STAT ACK: GET PPLD STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. A30808-X3247-L230-3-7619 759 Commands Base Station Controller CML:BSC GETINFO PPLD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPLD GETINFO PPLD Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The RSU running object and the RSU version. 2. The states and statuses of the PPLD: AST, OST, AVS, CST, STNDBYST, PRS. 3. The software inside the board; the available states are: LOAD_REQUIRED, START_REQUIRED, INSERVICE, OOS_IDLE and OOS_FAULT. The rst two values mean PPLD in rmware. 4. For each frame handled by the PPLD if it is running or not. 5. The LAPD pool. 6. For each physical handled lapd: the lapd type and number the operational state the availability status the pcm location where the lapd has been congured the PPLD circuit the lapd baud rate. The validity range of the object address ppldn can be found in Appendix A. System Responses: GETINFO PPLD ACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** INFORMATION *** GETINFO REPORT PPLD: NAME = PPLD:0 RSU RUNNING: RSUEXE 1-1 RSU VERSION: 02-06-01-01-00-00_00-01-10 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE STANDBY STATUS: PROVIDING_SERVICE PROCEDURAL STATUS: NONE GETINFO PPLD: NAME=PPLD:ppldn; 760 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SOFTWARE STATE: IN SERVICE PPLD CIRCUITS RUNNING: 0 1 LAPD POOL: 4 LPDLM 0 - 2: OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE ABIS/ASUB TIMESLOT: 3-10-0 (PCM NR-TS NR-SUBTS NR) PPLD CIRCUIT: 1 PPLD CIRCUIT BAUD RATE: RATE16KB LPDLS 0 - 0: OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE ABIS/ASUB TIMESLOT: 4-10 (PCM NR-TS NR-SUBTS NR) PPLD CIRCUIT: 1 PPLD CIRCUIT BAUD RATE: RATE64KB LPDLM 0 - 1: OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE ABIS/ASUB TIMESLOT: 2-9-1 (PCM NR- TS NR- SUBTS NR) PPLD CIRCUIT: 0 PPLD CIRCUIT BAUD RATE: RATE16KB LPDLS 0 - 1: OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE ABIS/ASUB TIMESLOT: 5-20 (PCM NR-TS NR-SUBTS NR) PPLD CIRCUIT: 2 PPLD CIRCUIT BAUD RATE: RATE64KB ... ... LPDLM 63 - 0: OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE ABIS/ASUB TIMESLOT: 4-15-2 (PCM NR-TS NR-SUBTS NR) PPLD CIRCUIT: 3 PPLD CIRCUIT BAUD RATE: RATE16KB LPDLS 63 - 0: OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE ABIS/ASUB TIMESLOT: 14-16 (PCM NR-TS NR-SUBTS NR) PPLD CIRCUIT: 1 PPLD CIRCUIT BAUD RATE: RATE64KB END OF REPORT A30808-X3247-L230-3-7619 761 Commands Base Station Controller CML:BSC GETINFO PPLD NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack PPLD: name = PPLD:0 nackCause = <nack cause> Application Guidelines: 1. Only equipped LPDLX links (LPDLM/R/S) should be displayed. 2. Numbers of PPLD Circuits Running are separated by spaces. Example of Command Execution Getinfo PPLD:NAME=PPLD:0; GETRELATIONSHIP PPLD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPLD GETRELATIONSHIP PPLD Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected HMO (Hardware Managed Object); the relationship information consist of all the FMOs (Functional Managed Object) using the HMO service. This information is included in the RELATED_FUNCTIONAL_OBJECTS attribute Note: Only equipped LPDLX links (LPDLM/R/S) should be displayed. Numbers of PPLD Circuits Running are separated by spaces. NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. GETRELATIONSHIP PPLD: NAME=PPLD:ppldn,ATTID=; 762 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller (ATTID parameter) and the attribute value depends on the working state of the target HMO. For the PPLD object the BTS, TRAU, PCMA, LPDLS, LPDLR, LPDLM and BTSM are the related FMOs. The validity range of the object address "ppldn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship PPLD:NAME=PPLD:0,ATTID=RELATED_FUNCTIONAL_OBJECTS; GETSUBO PPLD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPLD GETSUBO PPLD Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "ppldn" can be found in Appendix A. System Responses: GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected HMO the list of related FMOs is displayed (HMO to FMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_ATTRIBUTES The object instance does not provide any relationship attribute. GETSUBO PPLD: NAME=PPLD:ppldn; GETSUBO PPLD ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end there a message is displayed noti- fying the end of the subordinate list. GETSUBO PPLD NACK: A30808-X3247-L230-3-7619 763 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Getsubo PPLD:NAME=PPLD:0; GETTEST PPLD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPLD GETTEST PPLD Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the values of all the attributes belonging to a specified test object; the test object is created by the systemas a result of a request to start a test and it is deleted when the test terminates. The validity range of the object address "ppldn" can be found in Appendix A. System Responses: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. GETTEST PPLD: NAME=PPLD:ppldn; GETTEST PPLD ACK: GETTEST PPLD:NAME=PPLD:0; name = TEST:<n> mOts = PPLD:0 testState = It can assume one of the following values: not_initialized, idle, initializing, suspended, testing, terminating and disabled. testOutcome = It represents the test result: it can be Inconclusive (meaning-less: that is if the phases already executed were successful) or Fail (if at least one of the executed phases failed). testMonitor phaseId = It is a list of the phases to execute and their status that can be: pass, fail, running or waiting. phaseStatus = phaseId = phaseStatus = .... 764 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Gettest PPLD:NAME=PPLD:0; LOCK PPLD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPLD LOCK PPLD Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "ppldn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). GETTEST PPLD NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. LOCK PPLD: NAME=PPLD:ppldn; LOCK PPLD ACK: LOCK PPLD NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. A30808-X3247-L230-3-7619 765 Commands Base Station Controller CML:BSC Example of Command Execution Lock PPLD:NAME=PPLD:0; PERFTEST PPLD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPLD PERFTEST PPLD Applicability: Phase 2. Visibility level 2. Command Description: This command is used to performa test on the selected PPLD object; the test consist of the following phases: Preliminary Tests (start phase), Memory Test (WP1), HSCX Test (WP2), Loopback Test (WP3), R/W Loopback Register Test (WP4), Force Alarm Test (WP5), Alarm Test - TDPC Side (WP6), End Test (end phase). The validity range of the object address "ppldn" can be found in Appendix A. System Responses: PERFTEST PPLD: NAME=PPLD:ppldn; PERFTEST PPLD ACK: PERFTEST PPLD:NAME=PPLD:0; testObject=TEST:<n> The test results will be displayed at the end of the test phases. Result TEST: name = TEST:<n> testOutcome = This field represents the test result; one of the following values can be displayed: Pass all the test phases are successfully performed. Inconclusive the test is aborted by the system or the test is terminated by the operator. Fail if at least one of the executed phases fail. mOts = It is the identifier of the hardware object under test. testTermination = It specifies how the test is terminated, it can assume the following values: 766 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked" state, if the diagnostic is intrusive. 2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for test" state. When the test result is: "fail" the object goes in Disabled / Failed operational state; "pass" the object goes in Enabled operational state; "inconclusive" the object returns to the operational state previous to the test or in Enabled operational state. Example of Command Execution Perftest PPLD:NAME=PPLD:0; Normal all the test phases are performed. Abort the test is aborted by system. Cancel the test is terminated by operator. executedPhases phaseId = It represents the list of the executed test phases (in case of successful test result, all the test phases will be listed). additionalWords = .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases; they are displayed only for test stopped during it execution. phaseId = .... poprosedRepair Action = A list of most probable fail probable causes is shown (max four messages) PERFTEST PPLD NACK: NACK CAUSES: OTHER_TESTS_RUNNING Other incompatible tests are already running or no more parallel execution of tests possible. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. A30808-X3247-L230-3-7619 767 Commands Base Station Controller CML:BSC STOPTEST PPLD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPLD STOPTEST PPLD Applicability: Phase 2. Visibility level 2. Command Description: This command allows to terminate the test previously requested; the test can be in progress or in the waiting list (queued). In the first case the process that execute the diagnostic will be interrupted by executing the end phase; in the second case the test will be removed from the waiting list. The validity range of the object address "ppldn" can be found in Appendix A. System Responses: STOPTEST PPLD: NAME=PPLD:ppldn; STOPTEST PPLD ACK: STOPTEST PPLD:NAME=PPLD:0; testObject=TEST:<n> Result TEST: name = TEST:<n> testOutcome = inconclusive mOts = PPLD:0 testTermination = Cancel executedPhases phaseId = It represents the list of the executed test phases; the list is not shown for test in the waiting list (queued). .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases;the list is not shown for test in the waiting list (queued). phaseId = .... STOPTEST PPLD NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNABLE_TO_STOP_TEST The test can not be stopped. 768 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Stoptest PPLD:NAME=PPLD:0; UNLOCK PPLD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPLD UNLOCK PPLD Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "ppldn" can be found in Appendix A. System Responses: Application Guidelines: It is possible to unlock the PPLD card with the status in LOCKED and UNDER TEST. Example of Command Execution Unlock PPLD:NAME=PPLD:0; UNLOCK PPLD: NAME=PPLD:ppldn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. A30808-X3247-L230-3-7619 769 Commands Base Station Controller CML:BSC PPXL The PPXL object represents the high-capacity peripheral processor for LAPD and CCSS#7. GET PPXL STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXL GET PPXL STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the PPXL object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS). The validity range of the object address "ppxln" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get PPXL STAT:NAME=PPXL:0; GET PPXL STAT: NAME=PPXL:ppxln; GET PPXL STAT ACK: GET PPXL STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. 770 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETINFO PPXL Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXL GETINFO PPXL Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The RSU running object and the RSU version. 2. The rmware version. 3. The states and statuses of the PPXL: AST, OST, AVS, CST, PRS. 4. The software inside the board; the available states are: LOAD_REQUIRED, LOADED, INSERVICE, OOS_IDLE and OOS_FAULTED. 5. The operational data of the PPXL processor: real time, current OS time, OS time of last Task init, type and OS time of the last exception, number of task init from last Bring-up, number of exceptions since last Bring-up init and number of exceptions since last Task init, all dynamic memory pool type (the used and total buffer numbers from pool 0 to pool B) and the total and largest block available. 6. A single sweep "photograph" of the bits that are transmitted by the PPXL at a certain random instant. 7. A single sweep "photograph" of the bits that are received by the PPXL at a certain random instant. 8. For each physical handled lapd: the lapd type and number the operational state the availability status the standby status the lapd baud rate. the pcm location where the lapd has been congured the hdlc circuit the internal time slot and sub-time slot of the lapd inside the PPXL the hdlc state: FLAG or NO FLAG. 9. For each SS7 link handled: the ss7 number the operational state the availability status the pcm location where the ss7 has been congured the hdlc circuit the internal time slot of the ss7 inside the PPXL the hdlc state: FLAG or NO FLAG. The validity range of the object address "ppxln" can be found in Appendix A. GETINFO PPXL: NAME=PPXL:ppldn; A30808-X3247-L230-3-7619 771 Commands Base Station Controller CML:BSC System Responses: GETINFO PPXL ACK: BSC_CONTROLLER -> LMT_LOCAL 11:41:14 22/03/1999 *** INFORMATION *** GETINFO REPORT PPXL: NAME = PPXL:0 RSU RUNNING: RSUEXE 2-1 RSU VERSION: 02-06-01-00-00_01-10-09 FW VERSION: SFP1101 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE PROCEDURAL STATUS: NONE SOFTWARE STATE: IN SERVICE PENTIUM PROCESSOR: REAL TIME LOAD: 31% CURRENT OS TIME: 0049:05:54 OS TIME OF LAST TASK INIT: 0000:00:00 OS TIME OF LAST EXCEPTION: 0000:00:00 TYPE OF LAST EXCEPTION: 244 NUMBER OF TASK INIT SINCE LAST BRING-UP: 0001 NUMBER OF EXCEPTION SINCE LAST BRING-UP INIT: 0000 NUMBER OF EXCEPTION SINCE LAST TASK INIT: 0000 DYNAMIC MEMORY USAGE: 0: 0017/0031 1: 0057/1000 2:0109/0640 3: 0109/0300 4: 0017/0200 5: 0000/0150 6:0000/0100 7: 0001/1000 8: 0001/0300 9: 0000/0050 A:0000/0150 B: 0000/0100 TOTAL AND LARGEST BLOCK AVAILABLE: 0000000001/02234400 PPXL LINE TX SAMPLES: FA BC DF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF 772 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF E7 7E FC 3F FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF PPXL LINE RX SAMPLES: FA FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FA BC DF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF E7 7E FC 3F FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF LPDLM 0 - 0: LAPD POOL: 0 OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE STANDBY STATUS: PROVIDING SERVICE HDLC CIRCUIT BAUD RATE: RATE16KB ABIS/ASUB TIMESLOT: 3-10-0 (PCM NR - TS NR - SUBTS NR) HDLC CIRCUIT: 1 PPXL TIMESLOT: 10-3 (TS NR - SUBTS NR) HDLC STATE: FLAG LPDLM 0 - 1: LAPD POOL: 0 OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE STANDBY STATUS: HOT STANDBY HDLC CIRCUIT BAUD RATE: RATE64KB ABIS/ASUB TIMESLOT: 2-7 (PCM NR - TS NR - SUBTS NR) HDLC CIRCUIT: 9 PPXL TIMESLOT: 12 (TS NR - SUBTS NR) HDLC STATE: FLAG ... ... LPDLM 200 - 1: LAPD POOL: 0 OPERATIONAL STATE: ENABLED A30808-X3247-L230-3-7619 773 Commands Base Station Controller CML:BSC AVAILABILITY STATUS: NONE STANDBY STATUS: PROVIDING SERVICE HDLC CIRCUIT BAUD RATE: RATE16KB ABIS/ASUB TIMESLOT: 13-16-1 (PCM NR - TS NR - SUBTS NR) HDLC CIRCUIT: 4 PPXL TIMESLOT: 13-2 (TS NR - SUBTS NR) HDLC STATE: FLAG SS7L 0: OPERATIONAL STATE: DISABLED AVAILABILITY STATUS: FAILED ASUB TIMESLOT: 4-15 (PCM NR - TS NR) HDLC CIRCUIT: 240 PPXL TIMESLOT: 6 HDLC STATE: NO FLAG SS7L 1: OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE ASUB TIMESLOT: 4-16 (PCM NR - TS NR) HDLC CIRCUIT: 241 PPXL TIMESLOT: 127 HDLC STATE: FLAG END OF REPORT GETINFO PPXL NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack PPXL: name = PPXL:0 nackCause = <nack cause> NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 774 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. Only equipped LPDLX links (LPDLM/R/S) should be displayed. 2. Only equipped SS7 links should be displayed. Example of Command Execution Getinfo PPXL:NAME=PPXL:0; GETRELATIONSHIP PPXL Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXL GETRELATIONSHIP PPXL Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected HMO (Hardware Managed Object); the relationship information consist of all the FMOs (Functional Managed Object) using the HMO service. This information is included in the RELATED_FUNCTIONAL_OBJECTS attribute (ATTID parameter) and the attribute value depends on the working state of the target HMO. For the PPXL object the BTS, TRAU, PCMA, LPDLS, LPDLM, BTSMand SS7L are the related FMOs. The validity range of the object address "ppxln" can be found in Appendix A. System Responses: T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. GETRELATIONSHIP PPXL: NAME=PPXL:ppxln, ATTID=; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected HMO the list of related FMOs is displayed (HMO to FMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_ATTRIBUTES The object instance does not provide any relationship attribute. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. A30808-X3247-L230-3-7619 775 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Getrelationship PPXL:NAME=PPXL:0,ATTID=RELATED_FUNCTIONAL_OBJECTS; GETSUBO PPXL Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXL GETSUBO PPXL Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "ppxln" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo PPXL:NAME=PPXL:0; GETSUBO PPXL: NAME=PPXL:ppxln; GETSUBO PPXL ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end there a message is displayed noti- fying the end of the subordinate list. GETSUBO PPXL NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. 776 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETTEST PPXL Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXL GETTEST PPXL Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the values of all the attributes belonging to a specified test object; the test object is created by the systemas a result of a request to start a test and it is deleted when the test terminates. The validity range of the object address "ppxln" can be found in Appendix A. System Responses: Application Guidelines: None. GETTEST PPXL: NAME=PPXL:ppxln; GETTEST PPXL ACK: GETTEST PPXL:NAME=PPXL:0; name = TEST:<n> mOts = PPXL:0 testState = It can assume one of the following values: not_initialized, idle, initializing, suspended, testing, terminating and disabled. testOutcome = It represents the test result: it can be Inconclusive (meaning-less: that is if the phases already executed were successful) or Fail (if at least one of the executed phases failed). testMonitor phaseId = It is a list of the phases to execute and their status that can be: pass, fail, running or waiting. phaseStatus = phaseId = phaseStatus = .... GETTEST PPXL NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. A30808-X3247-L230-3-7619 777 Commands Base Station Controller CML:BSC Example of Command Execution Gettest PPXL:NAME=PPXL:0; LOCK PPXL Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXL LOCK PPXL Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". This command causes the board reset, so the RAM contents will be lost. All the LPDL(M/R/S) and the SS7L running on the locked PPXL are switched to the other PPXL, whereby the LAPD links will be temporary disconnected and a "Fast Alignment" will follow. The lock of PPXL does not cause the drop of the established calls, however the currently signalling processes (call setup and hand over) on the LAPD channels will be interrupted. The validity range of the object address "ppxln" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). 3. The LOCK of both PPXL objects leads to an interruption of the whole BSS call trafc. The LOCK command for the second board is not refused and there is no system warning generation. LOCK PPXL: NAME=PPXL:ppxln; LOCK PPXL ACK: LOCK PPXL NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. 778 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Lock PPXL:NAME=PPXL:0; PERFTEST PPXL Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXL PERFTEST PPXL Applicability: Phase 2. Visibility level 2. Command Description: This command is used to performa test on the selected PPXL object; the test consist of the following phases: Board reset and FW self-test (start phase), MPCC & TDPC Duam Test (WP1), Internal Circuit Test (WP2), ABIC Test (WP3), End Test (end phase). The validity range of the object address "ppxln" can be found in Appendix A. System Responses: PERFTEST PPXL: NAME=PPXL:ppxln; PERFTEST PPXL ACK: PERFTEST PPXL:NAME=PPXL:0; testObject=TEST:<n> The test results will be displayed at the end of the test phases. Result TEST: name = TEST:<n> testOutcome = This field represents the test result; one of the following values can be displayed: Pass all the test phases are successfully performed. Inconclusive the test is aborted by the system or the test is terminated by the operator. Fail if at least one of the executed phases fail. mOts = It is the identifier of the hardware object under test. testTermination = It specifies how the test is terminated, it can assume the following values: Normal all the test phases are performed. Abort the test is aborted by system. Cancel the test is terminated by operator. A30808-X3247-L230-3-7619 779 Commands Base Station Controller CML:BSC Application Guidelines: 1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked" state, if the diagnostic is intrusive. 2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for test" state. When the test result is: "fail" the object goes in Disabled / Failed operational state; "pass" the object goes in Enabled operational state; "inconclusive" the object returns to the operational state previous to the test or in Enabled operational state. Example of Command Execution Perftest PPXL:NAME=PPXL:0; STOPTEST PPXL Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXL STOPTEST PPXL executedPhases phaseId = It represents the list of the executed test phases (in case of successful test result, all the test phases will be listed). additionalWords = .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases; they are displayed only for test stopped during it execution. phaseId = .... poprosedRepair Action = A list of most probable fail probable causes is shown (max four messages) PERFTEST PPXL NACK: NACK CAUSES: OTHER_TESTS_RUNNING Other incompatible tests are already running or no more parallel execution of tests are possible. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. STOPTEST PPXL: NAME=PPXL:ppxln; 780 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 2. Command Description: This command allows to terminate the test previously requested; the test can be in progress or in the waiting list (queued). In the first case the process that execute the diagnostic will be interrupted by executing the end phase; in the second case the test will be removed from the waiting list. The validity range of the object address "ppxln" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Stoptest PPXL:NAME=PPXL:0; STOPTEST PPXL ACK: STOPTEST PPXL:NAME=PPXL:0; testObject=TEST:<n> Result TEST: name = TEST:<n> testOutcome = inconclusive mOts = PPXL:0 testTermination = Cancel executedPhases phaseId = It represents the list of the executed test phases; the list is not shown for test in the waiting list (queued). .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases;the list is not shown for test in the waiting list (queued). phaseId = .... STOPTEST PPXL NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNABLE_TO_STOP_TEST The test can not be stopped. A30808-X3247-L230-3-7619 781 Commands Base Station Controller CML:BSC UNLOCK PPXL Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXL UNLOCK PPXL Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". If the PPXL is not loaded (in this case it is in "disabled-not initialized" state), a SWload will start automatically on the PPXL. The LPDL(M/R/S) and the SS7L that in the BSC database are associated to the PPXL are switched to this PPXL from the other one, whereby the LAPD links will be temporary disconnected and a "Fast Alignment" will follow. The unlock of PPXL does not cause the drop of the established calls, however the currently signalling processes (call setup and hand over) on the LAPD channels will be interrupted. The validity range of the object address "ppxln" can be found in Appendix A. System Responses: Application Guidelines: It is possible to unlock the PPXL card with the status in LOCKED and UNDER TEST. Example of Command Execution Unlock PPXL:NAME=PPXL:0; UNLOCK PPXL: NAME=PPXL:ppxln; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. 782 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PPXP The PPXP object represents the peripheral processor that provides TD-SCDMA packet switched services. PCUTD is implemented by means of the PPXP card. PPXP cards are equipped with a load balancing redundancy scheme. This implies that all PPXP instances share TD- SCDMA packet service. The operator is allowed to configure a single PPXP card, but in such a case the load balancing redundancy scheme is not exploited. GET PPXP STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXP GET PPXP STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the PPXP object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS). The validity range of the object address "ppxpn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get PPXP STAT:NAME=PPXP:0; GET PPXP STAT: NAME=PPXP:ppxpn; GET PPXP STAT ACK: GET PPXP STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. A30808-X3247-L230-3-7619 783 Commands Base Station Controller CML:BSC GETINFO PPXP Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXP GETINFO PPXP Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The RSU running object and the RSU version. 2. The FW version. 3. The states and statuses of the PPXP: AST, OST, AVS, CST, PRS. 4. The software inside the board; the available states are: LOAD_REQUIRED, START_REQUIRED, IN_SERVICE, OUT_OF_SERV_IDLE and OUT_OF_SERV_FAULTED. 5. The operational data of the PPXP processor: real time, current OS time, OS time of last Task init, type and OS time of the last exception, number of task init from last Bring-up, number of exceptions since last Bring-up init and number of exceptions since last Task init, all dynamic memory pool type (the used and total buffer numbers from pool 0 to pool B) and the total and largest block available. 6. A single sweep "photograph" of the bits that are transmitted by the PPXP at a certain random instant. 7. A single sweep "photograph" of the bits that are received by the PPXP at a certain random instant. The validity range of the object address "ppxun" can be found in Appendix A. System Responses: GETINFO PPXP ACK: BSC_CONTROLLER -> LMT_LOCAL 11:41:14 22/03/1999 *** INFORMATION *** GETINFO REPORT PPXP: PPXP :0 RSU RUNNING: RSUEXE 2-1 RSU VERSION: 02-06-01-00-00_01-10-09 FW VERSION: SFP1101 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE GETINFO PPXP: NAME=PPXP:ppxpn; 784 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PROCEDURAL STATUS: NONE SOFTWARE STATE: IN SERVICE PENTIUM PROCESSOR: REAL TIME LOAD: 31% CURRENT OS TIME: 0049:05:54 OS TIME OF LAST TASK INIT: 0000:00:00 OS TIME OF LAST EXCEPTION: 0000:00:00 TYPE OF LAST EXCEPTION: 244 NUMBER OF TASK INIT SINCE LAST BRING-UP: 0001 NUMBER OF EXCEPTION SINCE LAST BRING-UP INIT: 0000 NUMBER OF EXCEPTION SINCE LAST TASK INIT: 0000 DYNAMIC MEMORY USAGE: 0: 0017/0031 1: 0057/1000 2:0109/0640 3: 0109/0300 4: 0017/0200 5: 0000/0150 6:0000/0100 7: 0001/1000 8: 0001/0300 9: 0000/0050 A:0000/0150 B: 0000/0100 TOTAL AND LARGEST BLOCK AVAILABLE: 0000000001/02234400 PPXP LINE TX SAMPLES: FA BC DF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF E7 7E FC 3F FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF PPXP LINE RX SAMPLES: FA FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FA BC DF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF E7 7E FC 3F FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF END OF REPORT GETINFO PPXP NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack PPXP: name = PPXP:0 nackCause = <nack cause> NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. A30808-X3247-L230-3-7619 785 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Getinfo PPXP:NAME=PPXP:0; GETRELATIONSHIP PPXP Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXP GETRELATIONSHIP PPXP Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected HMO (Hardware Managed Object); the relationship information consist of the all FMOs (Functional Managed Object) using the HMO service. This information is included in the RELATED_FUNCTIONAL_OBJECTS attribute (ATTID parameter) and the attribute value depends on the working state of the target HMO. For the PPXP object the PCUTD is the related FMOs. The validity range of the object address "ppxpn" can be found in Appendix A. System Responses: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. GETRELATIONSHIP PPXP: NAME=PPXP:ppxpn, ATTID=; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected HMO the list of related FMOs is displayed (HMO to FMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_ATTRIBUTES The object instance does not provide any relationship attribute. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. 786 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Getrelationship PPXP:NAME=PPXP:0,ATTID=RELATED_FUNCTIONAL_OBJECTS; GETSUBO PPXP Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXP GETSUBO PPXP Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "ppxpn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo PPXP:NAME=PPXP:0; GETSUBO PPXP: NAME=PPXP:ppxpn; GETSUBO PPXP ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end there a message is displayed noti- fying the end of the subordinate list. GETSUBO PPXP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. A30808-X3247-L230-3-7619 787 Commands Base Station Controller CML:BSC GETTEST PPXP Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXP GETTEST PPXP Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the values of all the attributes belonging to a specified test object; the test object is created by the systemas a result of a request to start a test and it is deleted when the test terminates. The validity range of the object address "ppxpn" can be found in Appendix A. System Responses: Application Guidelines: None. GETTEST PPXP: NAME=PPXP:ppxpn; GETTEST PPXP ACK: GETTEST PPXP:NAME=PPXP:0; name = TEST:<n> mOts = PPXP:0 testState = It can assume one of the following values: not_initialized, idle, initializing, suspended, testing, terminating and disabled. testOutcome = It represents the test result: it can be Inconclusive (meaning-less: that is if the phases already executed were successful) or Fail (if at least one of the executed phases failed). testMonitor phaseId = It is a list of the phases to execute and their status that can be: pass, fail, running or waiting. phaseStatus = phaseId = phaseStatus = .... GETTEST PPXP NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. 788 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Gettest PPXP:NAME=PPXP:0; LOCK PPXP Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXP LOCK PPXP Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "ppxpn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock PPXP:NAME=PPXP:0; LOCK PPXP: NAME=PPXP:ppxpn; LOCK PPXP ACK: LOCK PPXP NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. A30808-X3247-L230-3-7619 789 Commands Base Station Controller CML:BSC PERFTEST PPXP Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXP PERFTEST PPXP Applicability: Phase 2. Visibility level 2. Command Description: This command is used to perform a test on the selected PPXP object; the test consists of the following phases: Board reset and FW self-test (start phase), MPCC & TDPC Duam Test (WP1), Internal Circuit Test (WP2), End Test (end phase). The validity range of the object address "ppxpn" can be found in Appendix A. System Responses: PERFTEST PPXP: NAME=PPXP:ppxpn; PERFTEST PPXP ACK: PERFTEST PPXP:NAME=PPXP:0; testObject=TEST:<n> The test results will be displayed at the end of the test phases. Result TEST: name = TEST:<n> testOutcome = This field represents the test result; one of the following values can be displayed: Pass all the test phases are successfully performed. Inconclusive the test is aborted by the system or the test is terminated by the operator. Fail if at least one of the executed phases fail. mOts = It is the identifier of the hardware object under test. testTermination = It specifies how the test is terminated, it can assume the following values: Normal all the test phases are performed. Abort the test is aborted by system. Cancel the test is terminated by operator. executedPhases phaseId = It represents the list of the executed test phases (in case of successful test result, all the test phases will be listed). additionalWords = .... failedPhases 790 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked" state, if the diagnostic is intrusive. 2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for test" state. When the test result is: "fail" the object goes in Disabled / Failed operational state; "pass" the object goes in Enabled operational state; "inconclusive" the object returns to the operational state previous to the test or in Enabled operational state. Example of Command Execution Perftest PPXP:NAME=PPXP:0; STOPTEST PPXP Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXP STOPTEST PPXP Applicability: Phase 2. Visibility level 2. phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases; they are displayed only for test stopped during it execution. phaseId = .... poprosedRepair Action = A list of most probable fail probable causes is shown (max four messages) PERFTEST PPXP NACK: NACK CAUSES: OTHER_TESTS_RUNNING Other incompatible tests are already running or no more parallel execution of tests are possible. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. STOPTEST PPXP: NAME=PPXP:ppxpn; A30808-X3247-L230-3-7619 791 Commands Base Station Controller CML:BSC Command Description: This command allows to terminate the test previously requested; the test can be in progress or in the waiting list (queued). In the first case the process that execute the diagnostic will be interrupted by executing the end phase; in the second case the test will be removed from the waiting list. The validity range of the object address "ppxpn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Stoptest PPXP:NAME=PPXP:0; STOPTEST PPXP ACK: STOPTEST PPXP:NAME=PPXP:0; testObject=TEST:<n> Result TEST: name = TEST:<n> testOutcome = inconclusive mOts = PPXP:0 testTermination = Cancel executedPhases phaseId = It represents the list of the executed test phases; the list is not shown for test in the waiting list (queued). .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases;the list is not shown for test in the waiting list (queued). phaseId = .... STOPTEST PPXU NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNABLE_TO_STOP_TEST The test can not be stopped. 792 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller UNLOCK PPXP Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXP UNLOCK PPXP Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "ppxpn" can be found in Appendix A. System Responses: Application Guidelines: It is possible to unlock the PPXP card with the status in LOCKED and UNDER TEST. Example of Command Execution Unlock PPXP:NAME=PPXP:0; UNLOCK PPXP: NAME=PPXP:ppxpn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. A30808-X3247-L230-3-7619 793 Commands Base Station Controller CML:BSC PPXT The PPXT object represents the card that provides TD-SCDMA circuit switched services. PPXT stands for PPXX when the card is loaded with TD-SCDMA circuit switched software. CREATE PPXT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXT CREATE PPXT Applicability: Phase 2. Visibility level 2. Command Description: This command adds a PPXT card to the system. PPXT cards are present and equipped with a N+1 cold redundancy scheme. The total bandwidth for LAPD Abis channels per PPXT card is equal or less than 4 Mbps; this means that at most 64 LAPD Abis channels at 64kbps can be configured and in that case the maximum number of BTMTD sites per PPXT card is 64. In case of Multiple LAPD feature, up to 256 LAPD Abis channels at 16kbps are then supported. The validity range of the object address "ppxtn" can be found in Appendix A. System Responses: CREATE PPXT: NAME=PPXT:ppxtn; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. T_RESOURCE_CURRENTLY_BUSY The arrangement of the equipped PCU or PCUTD does not allow the creation of the PPXT object. PCU or PCUTD with the same instance are already created. UNSUCCESSFUL_COMMAND_REJECTED A PPXT instance can be created only if the network card (NTWCARD parameter of the BSC object) is NTWSNAP_STLP. UNSUCCESSFUL_EXCEEDED_OBJECT_NBR 794 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Create PPXT:NAME=PPXT:2; DELETE PPXT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXT DELETE PPXT Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a PPXT card previously created through the CREATE PPXT command. The validity range of the object address "ppxtn" can be found in Appendix A. System Responses: Application Guidelines: The relevant hardware can be unplugged after submitting the command. Example of Command Execution Delete PPXT:NAME=PPXT:2; The max number of PPXT has been reached; no other PPXT can be equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES Feature supported only by new MPCC/TDPC. DELETE PPXT: NAME=PPXT:ppxtn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The object instance must be in locked state. UNSUCCESSFUL_EXCEEDED_OBJECT_NBR The total number of PPXT equipped must exceed by 2 the total number of already equipped TDCU. A30808-X3247-L230-3-7619 795 Commands Base Station Controller CML:BSC GET PPXT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXT GET PPXT Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the EQUIPPED state of the PPXT card. The validity range of the object address "ppxtn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get PPXT:NAME=PPXT:0; GET PPXT STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXT GET PPXT STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the PPXT object: Administrative State (AST) Operational State (OST) GET PPXT NAME=PPXT:ppxtn; GET ACK: NAME: name GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. GET PPXT STAT: NAME=PPXT:ppxtn; 796 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Standby Status (STNDBY) Unknown Status (UNK). The validity range of the object address "ppxtn" can be found in Appendix A. System Responses: Application Guidelines: Only sets with raised bits are shown. Example of Command Execution Get PPXT STAT:NAME=PPXT:0; GET PPXT STAT ACK: GET PPXT STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. A30808-X3247-L230-3-7619 797 Commands Base Station Controller CML:BSC GETINFO PPXT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXT GETINFO PPXT Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The RSU running object and the RSU version. 2. The states and statuses of the PPXT: AST, OST, STNDBYST, PRS. 3. The software inside the board; the available states are: LOAD_REQUIRED, START_REQUIRED, INSERVICE, OOS_IDLE and OOS_FAULT. The rst two values mean PPXT in rmware. 4. For each frame handled by the PPXT if it is running or not. 5. The operational data of the PPXT processor: real time, current OS time, OS time of last Task init, type and OS time of the last exception, number of task init from last Bring-up, number of exceptions since last Bring-up init and number of exceptions since last Task init, all dynamic memory pool type (the used and total buffer numbers from pool 0 to pool B) and the total and largest block available. 6. A single sweep "photograph" of the bits that are transmitted by the PPXT at a certain random instant. 7. A single sweep "photograph" of the bits that are received by the PPXT at a certain random instant. 8. For each handled lpdlmtd: the btsmtd nymber the lpdlmtd number the operational state the availability status the standby status the pcm location where the lapd has been congured the internal timeslot and subtimeslot of the lapd inside the PPXL the lapd baud rate. The validity range of the object address ppxtn can be found in Appendix A. System Responses: GETINFO PPXT ACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** INFORMATION *** GETINFO REPORT PPXT: NAME = PPXT:0 GETINFO PPXT: NAME=PPXT:ppxtn; 798 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller RSU RUNNING: RSUEXE 1-1 RSU VERSION: 02-06-01-01-00-00_00-01-10 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED STANDBY STATUS: PROVIDING_SERVICE PROCEDURAL STATUS: NONE SOFTWARE STATE: IN SERVICE PENTIUM PROCESSOR: REAL TIME LOAD: 31% CURRENT OS TIME: 0049:05:54 OS TIME OF LAST TASK INIT: 0000:00:00 OS TIME OF LAST EXCEPTION: 0000:00:00 TYPE OF LAST EXCEPTION: 244 NUMBER OF TASK INIT SINCE LAST BRING-UP: 0001 NUMBER OF EXCEPTION SINCE LAST BRING-UP INIT: 0000 NUMBER OF EXCEPTION SINCE LAST TASK INIT: 0000 DYNAMIC MEMORY USAGE: 0: 0017/0031 1: 0057/1000 2: 0109/0640 3: 0109/0300 4: 0017/0200 5: 0000/0150 6: 0000/0100 7: 0001/1000 8: 0001/0300 9: 0000/0050 A: 0000/0150 B: 0000/0100 TOTAL AND LARGEST BLOCK AVAILABLE: 00000001/02234400 PPXT LINE TX SAMPLES: FA BC DF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF E7 7E FC 3F FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF AF FF FF FF PPXT LINE RX SAMPLES: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF AB BC DF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF E7 7E FC 3F FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF AF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF BTSMTD:20/LAPDMTD:0: OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE A30808-X3247-L230-3-7619 799 Commands Base Station Controller CML:BSC STANDBY STATUS: PROVIDING_SERVICE ABIS/ASUB TIMESLOT: 3-10-0 PPXT TIMESLOT: 3-10 BAUD RATE: RATE16KB BTSMTD:20/LAPDMTD:1: OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE STANDBY STATUS: HOT_STANDBY ABIS/ASUB TIMESLOT: 1-15 PPXT TIMESLOT: 4 BAUD RATE: RATE16KB .... BTSMTD:20/LAPDMTD:63: OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE STANDBY STATUS: HOT_STANDBY ABIS/ASUB TIMESLOT: 2-10 PPXT TIMESLOT: 1 BAUD RATE: RATE16KB END OF REPORT GETINFO PPXT NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack PPXT: name = PPXT:0 nackCause = <nack cause> Application Guidelines: None. Example of Command Execution Getinfo PPXT:NAME=PPXT:0; NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. 800 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETRELATIONSHIP PPXT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXT GETRELATIONSHIP PPXT Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected HMO (Hardware Managed Object); the relationship information consist of all the FMOs (Functional Managed Object) using the HMO service. This information is included in the RELATED_FUNCTIONAL_OBJECTS attribute (ATTID parameter) and the attribute value depends on the working state of the target HMO. The validity range of the object address "ppxtn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship PPXT:NAME=PPXT:0,ATTID=RELATED_FUNCTIONAL_OBJECTS; GETSUBO PPXT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXT GETSUBO PPXT Applicability: Phase 2. GETRELATIONSHIP PPXT: NAME=PPXT:ppxtn,ATTID=; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected HMO the list of related FMOs is displayed (HMO to FMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_ATTRIBUTES The object instance does not provide any relationship attribute. GETSUBO PPXT: NAME=PPXT:ppxtn; A30808-X3247-L230-3-7619 801 Commands Base Station Controller CML:BSC Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "ppxtn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo PPXT:NAME=PPXT:0; GETTEST PPXT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXT GETTEST PPXT Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the values of all the attributes belonging to a specified test object; the test object is created by the systemas a result of a request to start a test and it is deleted when the test terminates. The validity range of the object address "ppxtn" can be found in Appendix A. System Responses: GETSUBO PPXT ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end there a message is displayed noti- fying the end of the subordinate list. GETSUBO PPXT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. GETTEST PPXT: NAME=PPXT:ppxtn; GETTEST PPXT ACK: GETTEST PPXT:NAME=PPXT:0; name = TEST:<n> 802 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Gettest PPXT:NAME=PPXT:0; LOCK PPXT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXT LOCK PPXT Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "ppxtn" can be found in Appendix A. mOts = PPXT:0 testState = It can assume one of the following values: not_initialized, idle, initializing, suspended, testing, terminating and disabled. testOutcome = It represents the test result: it can be Inconclusive (meaning-less: that is if the phases already executed were successful) or Fail (if at least one of the executed phases failed). testMonitor phaseId = It is a list of the phases to execute and their status that can be: pass, fail, running or waiting. phaseStatus = phaseId = phaseStatus = .... GETTEST PPXT NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. LOCK PPXT: NAME=PPXT:ppxtn; A30808-X3247-L230-3-7619 803 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock PPXT:NAME=PPXT:0; PERFTEST PPXT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXT PERFTEST PPXT Applicability: Phase 2. Visibility level 2. Command Description: This command is used to performa test on the selected PPXT object; the test consist of the following phases: Preliminary Tests (start phase), Memory Test (WP1), HSCX Test (WP2), Loopback Test (WP3), R/W Loopback Register Test (WP4), Force Alarm Test (WP5), Alarm Test - TDPC Side (WP6), End Test (end phase). The validity range of the object address "ppxtn" can be found in Appendix A. LOCK PPXT ACK: LOCK PPXT NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. PERFTEST PPXT: NAME=PPXT:ppxtn; 804 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: PERFTEST PPXT ACK: PERFTEST PPXT:NAME=PPXT:0; testObject=TEST:<n> The test results will be displayed at the end of the test phases. Result TEST: name = TEST:<n> testOutcome = This field represents the test result; one of the following values can be displayed: Pass all the test phases are successfully performed. Inconclusive the test is aborted by the system or the test is terminated by the operator. Fail if at least one of the executed phases fail. mOts = It is the identifier of the hardware object under test. testTermination = It specifies how the test is terminated, it can assume the following values: Normal all the test phases are performed. Abort the test is aborted by system. Cancel the test is terminated by operator. executedPhases phaseId = It represents the list of the executed test phases (in case of successful test result, all the test phases will be listed). additionalWords = .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases; they are displayed only for test stopped during it execution. phaseId = .... poprosedRepair Action = A list of most probable fail probable causes is shown (max four messages) PERFTEST PPXT NACK: NACK CAUSES: OTHER_TESTS_RUNNING Other incompatible tests are already running or no more parallel execution of tests possible. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. A30808-X3247-L230-3-7619 805 Commands Base Station Controller CML:BSC Application Guidelines: 1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked" state, if the diagnostic is intrusive. 2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for test" state. When the test result is: "fail" the object goes in Disabled / Failed operational state; "pass" the object goes in Enabled operational state; "inconclusive" the object returns to the operational state previous to the test or in Enabled operational state. Example of Command Execution Perftest PPXT:NAME=PPXT:0; 806 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller STOPTEST PPXT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXT STOPTEST PPXT Applicability: Phase 2. Visibility level 2. Command Description: This command allows to terminate the test previously requested; the test can be in progress or in the waiting list (queued). In the first case the process that execute the diagnostic will be interrupted by executing the end phase; in the second case the test will be removed from the waiting list. The validity range of the object address "ppxtn" can be found in Appendix A. System Responses: STOPTEST PPXT: NAME=PPXT:ppxtn; STOPTEST PPXT ACK: STOPTEST PPXT:NAME=PPXT:0; testObject=TEST:<n> Result TEST: name = TEST:<n> testOutcome = inconclusive mOts = PPXT:0 testTermination = Cancel executedPhases phaseId = It represents the list of the executed test phases; the list is not shown for test in the waiting list (queued). .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases;the list is not shown for test in the waiting list (queued). phaseId = .... STOPTEST PPXT NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNABLE_TO_STOP_TEST The test can not be stopped. A30808-X3247-L230-3-7619 807 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Stoptest PPXT:NAME=PPXT:0; UNLOCK PPXT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXT UNLOCK PPXT Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "ppxtn" can be found in Appendix A. System Responses: Application Guidelines: It is possible to unlock the PPXT card with the status in LOCKED and UNDER TEST. Example of Command Execution Unlock PPXT:NAME=PPXT:0; UNLOCK PPXT: NAME=PPXT:ppxtn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. 808 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PPXU The PPXU object represents the high-capacity peripheral processor for PCU. GET PPXU STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXU GET PPXU STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the PPXU object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS). The validity range of the object address "ppxun" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get PPXU STAT:NAME=PPXU:0; GET PPXU STAT: NAME=PPXU:ppxun; GET PPXU STAT ACK: GET PPXU STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. A30808-X3247-L230-3-7619 809 Commands Base Station Controller CML:BSC GETINFO PPXU Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXU GETINFO PPXU Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The RSU running object and the RSU version. 2. The FW version. 3. The states and statuses of the PPXU: AST, OST, AVS, CST, PRS. 4. The software inside the board; the available states are: LOAD_REQUIRED, START_REQUIRED, IN_SERVICE, OUT_OF_SERV_IDLE and OUT_OF_SERV_FAULTED. 5. The operational data of the PPXU processor: real time, current OS time, OS time of last Task init, type and OS time of the last exception, number of task init from last Bring-up, number of exceptions since last Bring-up init and number of exceptions since last Task init, all dynamic memory pool type (the used and total buffer numbers from pool 0 to pool B) and the total and largest block available. 6. A single sweep "photograph" of the bits that are transmitted by the PPXUat a certain random instant. 7. A single sweep "photograph" of the bits that are received by the PPXU at a certain random instant. The validity range of the object address "ppxun" can be found in Appendix A. System Responses: GETINFO PPXU ACK: BSC_CONTROLLER -> LMT_LOCAL 11:41:14 22/03/1999 *** INFORMATION *** GETINFO REPORT PPXU: PPXU :0 RSU RUNNING: RSUEXE 2-1 RSU VERSION: 02-06-01-00-00_01-10-09 FW VERSION: SFP1101 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE GETINFO PPXU: NAME=PPXU:ppxun; 810 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PROCEDURAL STATUS: NONE SOFTWARE STATE: IN SERVICE PENTIUM PROCESSOR: REAL TIME LOAD: 31% CURRENT OS TIME: 0049:05:54 OS TIME OF LAST TASK INIT: 0000:00:00 OS TIME OF LAST EXCEPTION: 0000:00:00 TYPE OF LAST EXCEPTION: 244 NUMBER OF TASK INIT SINCE LAST BRING-UP: 0001 NUMBER OF EXCEPTION SINCE LAST BRING-UP INIT: 0000 NUMBER OF EXCEPTION SINCE LAST TASK INIT: 0000 DYNAMIC MEMORY USAGE: 0: 0017/0031 1: 0057/1000 2:0109/0640 3: 0109/0300 4: 0017/0200 5: 0000/0150 6:0000/0100 7: 0001/1000 8: 0001/0300 9: 0000/0050 A:0000/0150 B: 0000/0100 TOTAL AND LARGEST BLOCK AVAILABLE: 0000000001/02234400 PPXU LINE TX SAMPLES: FA BC DF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF E7 7E FC 3F FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF PPXU LINE RX SAMPLES: FA FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FA BC DF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF E7 7E FC 3F FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF END OF REPORT GETINFO PPXU NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack PPXU: name = PPXU:0 nackCause = <nack cause> NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. A30808-X3247-L230-3-7619 811 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Getinfo PPXU:NAME=PPXU:0; GETRELATIONSHIP PPXU Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXU GETRELATIONSHIP PPXU Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected HMO (Hardware Managed Object); the relationship information consist of the all FMOs (Functional Managed Object) using the HMO service. This information is included in the RELATED_FUNCTIONAL_OBJECTS attribute (ATTID parameter) and the attribute value depends on the working state of the target HMO. For the PPXU object the PCU is the related FMOs. The validity range of the object address "ppxun" can be found in Appendix A. System Responses: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. GETRELATIONSHIP PPXU: NAME=PPXU:ppxun, ATTID=; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected HMO the list of related FMOs is displayed (HMO to FMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_ATTRIBUTES The object instance does not provide any relationship attribute. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. 812 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Getrelationship PPXU:NAME=PPXU:0,ATTID=RELATED_FUNCTIONAL_OBJECTS; GETSUBO PPXU Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXU GETSUBO PPXU Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "ppxun" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo PPXU:NAME=PPXU:0; GETSUBO PPXU: NAME=PPXU:ppxun; GETSUBO PPXU ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end there a message is displayed noti- fying the end of the subordinate list. GETSUBO PPXU NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. A30808-X3247-L230-3-7619 813 Commands Base Station Controller CML:BSC GETTEST PPXU Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXU GETTEST PPXU Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the values of all the attributes belonging to a specified test object; the test object is created by the systemas a result of a request to start a test and it is deleted when the test terminates. The validity range of the object address "ppxun" can be found in Appendix A. System Responses: Application Guidelines: None. GETTEST PPXU: NAME=PPXU:ppxun; GETTEST PPXU ACK: GETTEST PPXU:NAME=PPXU:0; name = TEST:<n> mOts = PPXU:0 testState = It can assume one of the following values: not_initialized, idle, initializing, suspended, testing, terminating and disabled. testOutcome = It represents the test result: it can be Inconclusive (meaning-less: that is if the phases already executed were successful) or Fail (if at least one of the executed phases failed). testMonitor phaseId = It is a list of the phases to execute and their status that can be: pass, fail, running or waiting. phaseStatus = phaseId = phaseStatus = .... GETTEST PPXU NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. 814 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Gettest PPXU:NAME=PPXU:0; LOCK PPXU Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXU LOCK PPXU Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "ppxun" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock PPXU:NAME=PPXU:0; LOCK PPXU: NAME=PPXU:ppxun; LOCK PPXU ACK: LOCK PPXU NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. A30808-X3247-L230-3-7619 815 Commands Base Station Controller CML:BSC PERFTEST PPXU Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXU PERFTEST PPXU Applicability: Phase 2. Visibility level 2. Command Description: This command is used to perform a test on the selected PPXU object; the test consists of the following phases: Board reset and FW self-test (start phase), MPCC & TDPC Duam Test (WP1), Internal Circuit Test (WP2), End Test (end phase). The validity range of the object address "ppxun" can be found in Appendix A. System Responses: PERFTEST PPXU: NAME=PPXU:ppxun; PERFTEST PPXU ACK: PERFTEST PPXU:NAME=PPXU:0; testObject=TEST:<n> The test results will be displayed at the end of the test phases. Result TEST: name = TEST:<n> testOutcome = This field represents the test result; one of the following values can be displayed: Pass all the test phases are successfully performed. Inconclusive the test is aborted by the system or the test is terminated by the operator. Fail if at least one of the executed phases fail. mOts = It is the identifier of the hardware object under test. testTermination = It specifies how the test is terminated, it can assume the following values: Normal all the test phases are performed. Abort the test is aborted by system. Cancel the test is terminated by operator. executedPhases phaseId = It represents the list of the executed test phases (in case of successful test result, all the test phases will be listed). additionalWords = .... failedPhases 816 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked" state, if the diagnostic is intrusive. 2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for test" state. When the test result is: "fail" the object goes in Disabled / Failed operational state; "pass" the object goes in Enabled operational state; "inconclusive" the object returns to the operational state previous to the test or in Enabled operational state. Example of Command Execution Perftest PPXU:NAME=PPXU:0; STOPTEST PPXU Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXU STOPTEST PPXU Applicability: Phase 2. Visibility level 2. phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases; they are displayed only for test stopped during it execution. phaseId = .... poprosedRepair Action = A list of most probable fail probable causes is shown (max four messages) PERFTEST PPXU NACK: NACK CAUSES: OTHER_TESTS_RUNNING Other incompatible tests are already running or no more parallel execution of tests are possible. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. STOPTEST PPXU: NAME=PPXU:ppxun; A30808-X3247-L230-3-7619 817 Commands Base Station Controller CML:BSC Command Description: This command allows to terminate the test previously requested; the test can be in progress or in the waiting list (queued). In the first case the process that execute the diagnostic will be interrupted by executing the end phase; in the second case the test will be removed from the waiting list. The validity range of the object address "ppxun" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Stoptest PPXU:NAME=PPXU:0; STOPTEST PPXU ACK: STOPTEST PPXU:NAME=PPXU:0; testObject=TEST:<n> Result TEST: name = TEST:<n> testOutcome = inconclusive mOts = PPXU:0 testTermination = Cancel executedPhases phaseId = It represents the list of the executed test phases; the list is not shown for test in the waiting list (queued). .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases;the list is not shown for test in the waiting list (queued). phaseId = .... STOPTEST PPXU NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNABLE_TO_STOP_TEST The test can not be stopped. 818 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller UNLOCK PPXU Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXU UNLOCK PPXU Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "ppxun" can be found in Appendix A. System Responses: Application Guidelines: It is possible to unlock the PPXU card with the status in LOCKED and UNDER TEST. Example of Command Execution Unlock PPXU:NAME=PPXU:0; UNLOCK PPXU: NAME=PPXU:ppxun; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the object must not be already created in order to perform the command. A30808-X3247-L230-3-7619 819 Commands Base Station Controller CML:BSC PTPPKF The PTPPKF functional object represents the point to point service in a cell. In GSM 08.18, for point to point packet transfer, it is specified that a cell is identified by a BVCI so there is a one to one relation between cell and BVCI. CREATE PTPPKF CREATE PTPPKF: NAME=BTSM:btsmn/BTS:btsn/PTPPKF:ptppkfn, RACODE= ,RACOL= [,BSCDVMA=] [,PKTNDEC=] [,PKTNINC=] [,PKTNMA=] [,GRXLAMI=] [,GMSTXPMAC=] [,ABUTYP=] [,RAARET=] [,GPATH=] [,GTXINT=] [,GS=] [,GMANRETS=] [,GMANMSAL=] [,T3168=] [,T3192=] [,INICSCH=] [,NTWCOR=] [,GCELLRESH=] [,C31H=] [,C32QUAL=] [,TRESEL=] [,RARESH=] [,GHCSTH=] [,GHCSPC=] [,ALPHA=] [,TAVGW=] [,TAVGT=] [,PRPBCCH=] [,PCMECH=] [,NAVGI=] [,BSPBBLK=] [,BPAGCHR=] [,BPRACHR=] [,DRXTMA=] [,CACKTYP=] [,GAM=] [,GASTRTH=] [,GPDPDTCHA=] [,QSRHPRI=] [,FDDGQO=] [,GMANPRES=] [,TRFPSCTRLT=] [,NTWCREPPTR=] [,NTWCREPPIDL=] [,NTWCNDRXP=] [,CRESELTRHSOUT=] [,GUMTSSRHPRI=] [,GFDDQMI =] [,TDDGQO=] [,GFDDREPQTY=] [,GNMULBAC=] [,GFDDMURREP=] [,GTDDMURREP=] [,CSCH3CSCH4SUP=] [,BVCBSPPER=] [,BVCBHIPER=] [,BVCBMAPER=] [,BVCBLPER=] [,MSBSPPER=] [,MSBHIPER=] [,MSBMAPER=] [,MSBLPER=] [,ELKADPT=] [,BLERAVEUL=] [,BLERAVEDL=] [,EMFA1UNIR8PSK=] [,EMFAP1UNIR8PSK=] [,EMFB1UNIR8PSK=] [,EMFCUNIR8PSK=] [,EMFGUNIR8PSK=] [,EMFCUNIRGMSK=] [,EMFGUNIRGMSK=] [,EMCSFAMA1DL=] [,EMCSFAMAP1DL=] [,EMCSFAMB1DL=] [,EMCSFAMCDL=] [,EMCSFAMGDL=] [,IMCSULNIR8PSK=] [,IMCSULNIRGMSK=] [,INIMCSDL=] [,RAENV=] [,STGTTLLIINF=] [,INIBLER=] [,SCHWEIPRI1=] [,SCHWEIPRI2=] [,SCHWEIPRI3=] [,SCHWEIPRI4=] [,EBCCHTRX=] [,EEDGE=] [,EGPRS=] [,BEPAVGP=] [,EGWSONETS=] [,EGWSTWOTS=] [,EGWSTHREETS=] [,EGWSFOURTS=] [,EGWSFIVETS=] [,EGWSSIXTS=] [,EGWSSEVENTS=] [,EGWSEIGHTTS=] [,EGPLGPONETS=] [,EGPLGPTWOTS=] [,EGPLGPTHREETS=] [,EGPLGPFOURTS=] [,EGPLGPFIVETS=] [,EGPLGPSIXTS=] [,EGPLGPSEVENTS=] [,EGPLGPEIGHTTS=] [,PERSTLVPRI1=] [,PERSTLVPRI2=] [,PERSTLVPRI3=] [,PERSTLVPRI4=] [,NCC1TH=] [,NCRARESH=] [,NCSARA=] [,NCTRFPSCTH=] [,CRESELTHRINP=] [,PKTMEASREPCNT=]; 820 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF CREATE PTPPKF Applicability: Phase 2. Visibility level 2. Command Description: This command creates an instance of the PTPPKF object class. It can be done only if the super-ordinate BTS and all the necessary NSVCs (at least one) are created. Creation of PTPPKF object means allowing GPRS service in a specific cell. The information to the mobile about the GPRS service in the network are provided via system information. The status at creation will be Locked-Disabled/Offline. On the created PTPPKF, a BVCI reset procedure is performed toward SGSN. After a positive termination of the procedure, the PTPPKF shall became Locked-Enabled and a block procedure is necessary to reflect the locked condition. Validity ranges of the object addresses btsmn, btsn and "ptppkfn" can be found in Appendix A. System Responses: CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The relevant BTS object instance must be already created. At least one PCU instance must already exist. At least one NSVC on a PCU must be created. UNSUCCESSFUL_VAR_OUT_OF_RANGE The ThresholdIdleChanHV field of the GASTRTH attribute has to be lower than the ThresholdIdleChanVH field. The ThresholdIdleChanVH field of the GASTRTH attribute has to be lower than or equal to the ThresholdIdleChanEU field. UNSUCCESSFUL_INVALID_STATUS The command must be done in LOCKED state if the following attributes are changed: RACODE, RACOL, GPDPDTCHA, EEDGE. In order to set the CSCH3CSCH4SUP attribute the PTPPKF object must be in LOCKED state. In order to set the SCHWEIPRI1, SCHWEIPRI2, SCHWEIPRI3, SCHWEIPRI4 attributes the PTPPKF object must be in LOCKED state. INCOMP_NESWLOAD_VS_MESSAGE The CSCH3CSCH4SUP cannot be set at TRUE if the SWVersion running on the superordinated BTSMbelongs to BR6.0 release (see EXPSWV parameter description). A30808-X3247-L230-3-7619 821 Commands Base Station Controller CML:BSC BEPAVGP, EGWSONETS...EGWSEIGHTS, EGPLGPONETS...EGPLGPEIGHTS attributes can not be set at a value different from NULL, if the SW Version running on the superordinated BTSM object belongs to BR6.0 release (see EXPSWV parameter description). The attribute EBCCHTRX can not be set at TRUE if the SWVersion running on the superordinated BTSM object belongs to BR6.0 release (see EXPSWV parameter description). The attribute EEDGE can not be set at TRUE if the SW Version running on the superordinated BTSM object belongs to BR6.0 release (see EXPSWV parameter description). BEPAVGP, EGWSONETS..EGWSEIGHTS, EGPLGPONETS..EGPLGPEIGHTS can not be set at a value different from NULL, if the BTSE is not of one of the following types: BS-240, BS-240SR, BS-241, BS-241SR, BS-240XL, BS-240XLSR, BS-40, BS-41. BEPAVGP, EGWSONETS..EGWSEIGHTS, EGPLGPONETS..EGPLGPEIGHTS can not be set at NULL value , if the BTSE is of one of the following types: BS-240, BS-240SR, BS-241, BS-241SR, BS-240XL, BS-240XLSR, BS-40, BS-41. The attribute EBCCHTRX can not be set at TRUE if the BTSE is not of one of the following types: BS-240, BS-240SR, BS-241, BS-241SR, BS-240XL, BS-240XLSR, BS-40, BS-41. The attribute EEDGE can not be set at TRUE if the BTSE is not of one of the following types: BS-240, BS-240SR, BS-241, BS-241SR, BS-240XL, BS-240XLSR, BS-40, BS-41. The following attributes: EMFA1UNIR8PSK, EMFAP1UNIR8PSK, EMFB1UNIR8PSK, EMFCUNIR8PSK, EMFGUNIR8PSK, EMFCUNIRGMSK, EMFGUNIRGMSK, EMCSFAMA1DL, EMCSFAMAP1DL, EMCSFAMB1DL, EMCSFAMCDL, EMCSFAMGDL, IMCSULNIR8PSK, IMCSULNIRGMSK, INIMCSDL can not be set at a value different from NULL if the SW Version running on the superordinated BTSM object belongs to BR6.0 release (see EXPSWV parameter description). The following attributes: EMFA1UNIR8PSK, EMFAP1UNIR8PSK, EMFB1UNIR8PSK, EMFCUNIR8PSK, EMFGUNIR8PSK, EMFCUNIRGMSK, EMFGUNIRGMSK, EMCSFAMA1DL, EMCSFAMAP1DL, EMCSFAMB1DL, EMCSFAMCDL, EMCSFAMGDL, IMCSULNIR8PSK, IMCSULNIRGMSK, INIMCSDL can not be set at a value different from NULL if the HW Version of the BTSE is different from BTS+. The following attributes: EMFA1UNIR8PSK, EMFAP1UNIR8PSK, EMFB1UNIR8PSK, EMFCUNIR8PSK, EMFGUNIR8PSK, EMFCUNIRGMSK, EMFGUNIRGMSK, EMCSFAMA1DL, EMCSFAMAP1DL, EMCSFAMB1DL, EMCSFAMCDL, EMCSFAMGDL, IMCSULNIR8PSK, IMCSULNIRGMSK, INIMCSDL can not be set at NULL value if the HWVersion of the BTSE is BTS+. If the SWVersion running on the superordinated BTSM object (see EXPSWV parameter description), the ELKADPT attribute must be set to FALSE. UNSUCCESSFUL_CODING_SCHEME_NOT_SUPPORTED In order to set CSCH3CSCH4SUP at TRUE, CSCH3CSCH4SUP in BSC object must be TRUE. 822 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller In order to set CSCH3CSCH4SUP at TRUE, the PUREBBSIG44CONF attribute in BTS object must be TRUE or NULL. The INICSCH attribute cannot be set at CS3 or CS4 if the CSCH3CSCH4SUP attribute is set at FALSE and vice versa. The INICSCH attribute cannot be set to a value greater than CS2 if Bit 25 of MNTBMASK has been set to 1. UNSUCCESSFUL_EDGE_NOT_SUPPORTED The attribute EEDGE can not be set at TRUE if the ESUP attribute of BSC object is set at FALSE or no TRXs in the cell have TRXMD set at EDGE. The attribute EBCCHTRX can not be set at TRUE if the related BCCH TRX has TRXMD set at GSM or the ESUP attribute of BSC object is set at FALSE. UNSUCCESSFUL_GPRS_NOT_SUPPORTED The attribute EGPRS can not be set at TRUE if no TRXs in the cell have GSUP set at TRUE. UNSUCCESSFUL_INVALID_ATTRIBUTES The attribute EGPRS can not be set at FALSE if EEDGE is set at TRUE. The attribute EEDGE can not be set at TRUE if EGPRS is set at FALSE. The attribute EEDGE can not be set at TRUE if CSCH3CSCH4SUP is set at FALSE The following relations between the SCHWEIPRI1, SCHWEIPRI2, SCHWEIPRI3, SCHWEIPRI4 attributes must be satisfied: SCHWEIPRI1 >= SCHWEIPRI2 >= SCHWEIPRI3 >= SCHWEIPRI4. The BVCBHIPER attribute cannot be set at a value lower or equal than BVCBLPER. The MSBHIPER attribute cannot be set at a value lower or equal than MSBLPER. EGWSyTS value must be major or equal than EGWSxTS and minor or equal than EGWSzTS, where x < y< z The ELKADPT attribute cannot be set to TRUE if the NTWCARD parameter (BSC object) is set to NTWSN16. The NCTRFPSCTH attribute must be set to a value less than CRESELTHRSOUT. The NCTRFPSCTH attribute must be set to a value greater than CRESELTHRINP. The STGTTLLINF attribute must be set to a value greater than TRFPSCTRLT. UNSUCCESSFUL_WRONG_MCS The IMCSULNIR8PSKchosen does not belong to the family enabled for Uplink 8PSK without Incremental Redundancy, i.e EMFA1UNIR8PSK, EMFAP1UNIR8PSK, EMFB1UNIR8PSK, EMFCUNIR8PSK, EMFGUNIR8PSK. The IMCSULNIRGMSK chosen does not belong to the family enabled for GSMK without Incremental Redundancy, i.e. EMFCUNIRGMSK and EMFGUNIRGMSK. A30808-X3247-L230-3-7619 823 Commands Base Station Controller CML:BSC Application Guidelines: 1. The value of BSPBBLK, BPAGCHR and BPRACHR parameters has to be set in such a way to have at least one block of each of the following types: PBCCH, PPCH, PAGCH for DL; PRACH for UL. For instance, if BSPBBLK is set at 1 the maximum value for BPAGCHR is 9. 2. The difference between the ThresholdIdleChanVH and ThresholdIdleChanHV fields of GASTRTH parameter has to be set at a value not too much high, in order to have a real hysteresis behaviour. 3. The following relationships must be veried: NCTRFPSCTH < = CRESELTHRSOUT NCTRFPSCTH > CRESELTHRINP 4. The maximum admitted value of the GMANPRES attribute is equal to 190. When setting the value of this attribute, the operator must pay attention about how many TRXs are equipped, and how many timeslots he would like to reserve to GPRS/EGPRS services, otherwise he could lose all circuit switched trafc. For example if a BTS is equipped with two TRXs, the GMANPRES value must not be greater than 14, otherwise CS calls are not allowed in the cell (considering that at least two timeslots are used for BCCH and SDCCH channels). In this case if the operator wants to reserve statically half of the resources for GPRS/EGPRS, he has to set GMANPRES=7. Example of Command Execution Create PTPPKF:NAME=BTSM:0/BTS:0/PTPPKF:0,RACODE=1, RACOL=5,BSCDVMA=5, PKTNDEC=6,PKTNINC=7,PKTNMA=0,GRXLAMI=10, GMSTXPMAC=20,ABUTYP=0,RAARET=0,GPATH=2,GTXINT=9,GS=3, GMANRETS=2, GMANMSAL=7-9,T3166_68=2,T3192=3,INICSCH=CS1, NTWCOR=0,GCELLRESH=7,C31H=0,C31QUAL=TRUE, TRESEL=5,RARESH=6,GHCSTH=11,GHCSPC=4, ALPHA=8,TAVGW=15,TAVGT=7, PRPBCCH=12,PCMECH=0,NAVGI=9, BSPBBLK=0,BPAGCHR=5,PBRACHR=8, DRXTMA=4,CACKTYP=1, GASTRTH=10-20-20,GPDPDTCHA=0,QSRHPRI=UMDB82,FDDGQO=DB08, GMANPRES=0, TRFPSCTRLT=5, NTWCREPPIDL=MSEC480, NTWCREPPIDL=MSEC61440, NTWCNDRXP=MSEC960, CRESELTRHSOUT=85, GUMTSSRHPRI=FALSE, GFDDQMI=MDB18, TDDGQO=DB16, GFDDREPQTY=RSCP, GNMULBAC=2, GFDDMURREP=1, GTDDMURREP=1, CSCH3CSCH4SUP=FALSE, BVCBHIPER=70,BVCBSPPER=PER200, BVCBMAPER=PER100,BVCBLPER=PER60,MSBSPPER=PER200, MSBHIPER=PER70, MSBMAPER=PER100,MSBLPER=PER60,ELKADPT=FALSE, BLERAVEUL=UNIT400, BLERAVEDL=UNIT400, EMFA1UNIR8PSK=TRUE, EMFAP1UNIR8PSK=FALSE, EMFB1UNIR8PSK=FALSE, EMFCUNIR8PSK=FALSE, EMFGUNIR8PSK=FALSE, EMFCUNIRGMSK=FALSE, EMFGUNIR- GMSK=TRUE,EMCSFAMA1DL=TRUE, EMCSFAMAP1DL=FALSE, The INIMCSDL chosen does not belong to the family enabled for EMCSFAMA1DL, i.e. EMCSFAMAP1DL, EMCSFAMB1DL, EMCSFAMCDL, EMCSFAMGDL. UNSUCCESSFUL_HOPPING_SYSTEM_INCONSISTENT If the BCCHis involved in a BBHOP hopping lawand the BCCHTRX has TRXMD=EDGE, EBCCHTRX cannot be set at FALSE. 824 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller EMCSFAMB1DL=FALSE,EMCSFAMCDL=FALSE, EMCSFAMGDL=FALSE,IMCSULNIR8PSK=MCS6,IMCSULNIRGMSK=MCS3, INIMCSDL=MCS9,RAENV=HIGHDIV,STGTTLLIINF=60,INIBLER=PER20, SCHWEIPRI1=7,SCHWEIPRI2=6,SCHWEIPRI3=5,SCHWEIPRI4=2, EBCCHTRX=FALSE,EEDGE=TRUE,EGPRS=TRUE,BEPAVGP=5, EGWSONETS=192,EGWSTWOTS=256,EGWSTHREETS=384,EGWSFOURTS=512, EGWSFIVETS=640,EGWSSIXTS=768,EGWSSEVENTS=896, EGWSEIGHTTS=1024,EGPLGPONETS=16,EGPLGPTWOTS=16, EGPLGPTHREETS=16,EGPLGPFOURTS=16,EGPLGPFIVETS=16, EGPLGPSIXTS=16,EGPLGPSEVENTS=16,EGPLGPEIGHTTS=16, PERSTLVPRI1=5,PERSTLVPRI2=5,PERSTLVPRI3=5,PERSTLVPRI4=5, NCC1TH=DB03,NCRARESH=DB00,NCSAMERA=TRUE, NCTRFPSCTH=75, CRESELTHRINP=66, PKTMEASREPCNT; DELETE PTPPKF Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF DELETE PTPPKF Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a previously created instance of the PTPPKF object class. It can be done only if the object is in Locked state. The appropriate system information shall be sent on Um interface to inform the mobile about availability of the service. Because of also SGSN knows the BVCI connected to this object, appropriate actions to inform it about new PTPPKF configurations should be taken by BSC. Validity ranges of the object addresses btsmn, btsn and "ptppkfn" can be found in Appendix A. System Responses: DELETE PTPPKF NAME=BTSM:btsmn/BTS:btsn/PTPPKF:ptppkfn; DELETE ACK: SUCCESSFUL DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS A30808-X3247-L230-3-7619 825 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Delete PTPPKF:NAME=BTSM:0/BTS:0/PTPPKF:0; Before deleting a PTPPKF, the relative object instance must be in LOCKED state. UNSUCCESSFUL_SUBORDINATE_EQUIPPED The PTPPKF cannot be deleted if there is a subordinate TRX with GSUP set at TRUE. A GPRS handover relationship (ADJC) can be configured only between two GPRS cells (PTPPKF equipped). This means that no incoming relationship must contain GSUPset at TRUE; this parameter cannot be TRUE in any ADJC object in the BSC referring the BTS with the same instance number of the PTPPKF being deleted as TGTCELL. The same nack cause is generated for the outgoing ADJC relationship: GSUP cannot be TRUE in any ADJC instance subordinated to the BTS with the same instance number of the PTPPKF being deleted. 826 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET PTPPKF Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF GET PTPPKF Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameter values of an instance of the PTPPKF object class. Validity ranges of the object addresses btsmn, btsn and "ptppkfn" can be found in Appendix A. GET PTPPKF NAME=BTSM:btsmn/BTS:btsn/PTPPKF:ptppkfn [,REQATTL=RACODE, RACOL, BSCDVMA, PKTNDEC, PKTNINC, PKTNMA,GRXLAMI, GMSTXPMAC, ABUTYP, RAARET, GPATH, GTXINT, GS, GMANRETS, GMANMSAL, T3168, T3192, INICSCH, NTWCOR, GCELLRESH, C31H, C32QUAL, TRESEL, RARESH, GHCSTH, GHCSPC, ALPHA, TAVGW, TAVGT, PRPBCCH, PCMECH, NAVGI, BSPBBLK, BPAGCHR, BPRACHR, DRXTMA, CACKTYP, GAM, GASTRTH, GPDPDTCHA, QSRHPRI, FDDGQO, GMANPRES, TRFPSCTRLT, NTWCREPPTR, NTWCREP- PIDL, NTWCNDRXP, CRESELTRHSOUT, GUMTSSRHPRI, GFDDQMI, TDDGQO, GFDDREPQTY, GNMULBAC, GFDDMURREP, GTDDMURREP, CSCH3CSCH4SUP, BVCBHIPER, BVCBSPPER, BVCBMAPER, BVCBLPER, MSBSPPER, MSBHIPER, MSBMAPER, MSBLPER, ELKADPT, BLERAVEUL, BLERAVEDL, EMFA1UNIR8PSK, EMFAP1UNIR8PSK, EMFB1UNIR8PSK, EMFCUNIR8PSK, EMFGUNIR8PSK, EMFCUNIRGMSK, EMFGUNIRGMSK, EMCSFAMA1DL, EMCSFAMAP1DL, EMCSFAMB1DL, EMCSFAMCDL, EMCSFAMGDL, IMCSULNIR8PSK, IMCSULNIRGMSK, INIMCSDL, RAENV, STGTTLLIINF, INIBLER, SCHWEIPRI1, SCHWEIPRI2, SCHWEIPRI3, SCHWEIPRI4, EBCCHTRX, EEDGE, EGPRS, BEPAVGP, EGWSONETS, EGWSTWOTS, EGWSTHREETS, EGWSFOURTS, EGWSFIVETS, EGWSSIXTS, EGWSSEVENTS, EGWSEIGHTTS, EGPLGPONETS, EGPLGPTWOTS, EGPLGPTHREETS, EGPLGPFOURTS, EGPLGPFIVETS, EGPLGPSIXTS, EGPLGPSEVENTS, EGPLGPEIGHTTS, PERSTLVPRI1, PERSTLVPRI2, PERSTLVPRI3, PERSTLVPRI4,NCC1TH, NCRARESH, NCSARA, NCTRFPSCTH, CRESELTHRINP, PKTMEASREPCNT]; A30808-X3247-L230-3-7619 827 Commands Base Station Controller CML:BSC System Responses: GET ACK: NAME: name RACODE: RoutingAreaCode RACOL: RoutingAreaColour BSCDVMA: bscountdownValueMax PKTNDEC: packetNumberDecrement PKTNINC: packetNumberIncrement PKTNMA: packetNumberMax GRXLAMI: gprsLevAccessMin GMSTXPMAC: gprsMxTxPwrMaxCch ABUTYP: accessBurstType RAARET: randomAccessRetry GPATH: gprsPriorityAccessThreshold GTXINT: gprsTxInterval GS: gprsSlot GMANRETS: gprsMaxNumberRetransmission GMANMSAL: gprsMaxNumberMsAllocated T3168: t3168 T3192: t3192 INICSCH: initialCodingScheme NTWCOR: networKControlOrder GCELLRESH: gprsCellReselectHysteresis C31H: c31Hysteresis C32QUAL: c32Qualifier TRESEL: tResel RARESH: routingAreaReselectHysteresis GHCSTH: gprsHierarchycalCellStructureThreshold GHCSPC: gprsHierarchycalCellStructurePriorityClass ALPHA: alphaPowerControlAlgorithm TAVGW: tAverageWeight TAVGT: AverageTime PRPBCCH: powerRedactionOnPbcch PCMECH: oowerControlMeasurementChannel NAVGI: nAverageInterference BSPBBLK bsPbcchBlocks BPAGCHR: bsPagchBlocksReserved BPRACHR: bsPrachBlocksReserved DRXTXMA: discontinousReceptionTimerMax CACKTYP: controlAcknowledgementType GAM: gamma GASTRTH: gprsAllocationStrategyThresholds GPDPDTCHA: gprsPercentageOfDinamicPdtchAvailable QSRHPRI: qSearchPriority FDDGQO: fddGPRSQOffset GMANPRES: gprsMaxNumberPDCHRes TRFPSCTRLT TrafficPSControlTimer 828 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller NTWCREPPTR: NetworkControlReportPeriodTransfer NTWCREPPIDL: networkControlReportPeriodIdle NTWCNDRXP: networkControlNonDRXPeriod CRESELTRHSOUT: cellReselectionThresholdOutput GUMTSSRHPRI: gprsUmtsSearchPriority GFDDQMI: GprsFddQmin TDDGQO: tddGprsQOffset GFDDREPQTY: GprsFddReportingQuantity GNMULBAC: gprsNMultibandCell GFDDMURREP gprsFddMultiratReporting GTDDMURREP gprsTddMultiratReporting CSCH3CSCH4SUP: codingScheme3CodingScheme4Support BVCBHIPER: bvcBucketHighPercentage BVCBSPPER: bvcBucketSizePcuPercentage BVCBMAPER: bvcBucketMaxPercentage BVCBLPER: bvcBucketLowPercentage MSBSPPER: msBucketSizePcuPercentage MSBHIPER: msBucketHighPercentage MSBMAPER: msBucketMaxPercentage MSBLPER: msBucketLowPercentage ELKADPT: enableLinkAdaptation BLERAVEUL: blockErrorRateAveragingPeriodUplink BLERAVEDL: blockErrorRateAveragingPeriodDownlink EMFA1UNIR8PSK: enMcsFamAMcs1UplinkWoutIncrRed8Psk EMFAP1UNIR8PSK: enMcsFamApMcs1UplinkWoutIncrRed8Psk EMFB1UNIR8PSK: enMcsFamBMcs1UplinkWoutIncRed8Psk EMFCUNIR8PSK: enMcsFamCUplinkWoutIncRed8Psk EMFGUNIR8PSK: enMcsFamGmskUplinkWoutIncRed8Psk EMFCUNIRGMSK: enMcsFamCUplinkWoutIncrRedGmsk EMFGUNIRGMSK: enMcsFamGmskUplinkWoutIncrRedGmsk EMCSFAMA1DL: enMcsFamAMcs1Downlink EMCSFAMAP1DL: enMcsFamAPaddingMcs1Downlink EMCSFAMB1DL: enMcsFamBMcs1Downlink EMCSFAMCDL: enMcsFamCDownlink EMCSFAMGDL: enMcsFamGmskDownlink IMCSULNIR8PSK: initialMcsUplinkWoutIncrRed8psk IMCSULNIRGMSK: initialMcsUplinkWoutIncrRedGmsk INIMCSDL: initialMcsDownlink RAENV: radioEnvironment STGTTLLIINF: storageTimeTLLIInfo INIBLER: initialBLER SCHWEIPRI1: schedulingWeightOfPriority1 SCHWEIPRI2: schedulingWeightOfPriority2 SCHWEIPRI3: schedulingWeightOfPriority3 SCHWEIPRI4: schedulingWeightOfPriority4 EBCCHTRX: egprs8pskOnBcchTrx EEDGE: enableEdge A30808-X3247-L230-3-7619 829 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get PTPPKF:NAME=BTSM:0/BTS:0/PTPPKF:0,REQATTL=RACODE& RACOL&BSCDVMA&PKTNDEC&PKTNINC&PKTNMA&GRXLAMI&GMSTXPMAC& ABUTYP&RAARET&GPATH>XINT&GS&GMANRETS&GMANMSAL& T3168&T3192&INICSCH&NTWCOR&GCELLRESH&C31H&C32QUAL& TRESEL&RARESH&GHCSTH&GHCSPC& ALPHA&TAVGW&TAVGT&PRPBCCH&PCMECH&NAVGI&BSPBBLK&BPAGCHR& BPRACHR&DRXTMA&CACKTYP&GAM&GASTRTH&GPDPDTCHA&QSRHPRI& FDDGQO&GMANPRES&TRFPSCTRLT&NTWCREPPTR&NTWCREP- PIDL&NTWCNDRXP&CRESELTRHSOUT&GUMTSS- RHPRI&GFDDQMI&TDDGQO&GFDDREPQTY&GNMULBAC&GFDDMURREP& EGPRS: enableGprs BEPAVGP: bitErrorProbabilityAveragePeriod EGWSONETS: egprsWindowSizeOneTimeSlot EGWSTWOTS: egprsWindowSizeTwoTimeSlot EGWSTHREETS: egprsWindowSizeThreeTimeSlot EGWSFOURTS: egprsWindowSizeFourTimeSlot EGWSFIVETS: egprsWindowSizeFiveTimeSlot EGWSSIXTS: egprsWindowSizeSixTimeSlot EGWSSEVENTS: egprsWindowSizeSevenTimeSlot EGWSEIGHTTS: egprsWindowSizeEightTimeSlot EGPLGPONETS: egprsPollingPeriodOneTimeSlot EGPLGPTWOTS: egprsPollingPeriodTwoTimeSlot EGPLGPTHREETS: egprsPollingPeriodThreeTimeSlot EGPLGPFOURTS: egprsWindowSizeFourTimeSlot EGPLGPFIVETS: egprsPollingPeriodFiveTimeSlot EGPLGPSIXTS: egprsPollingPeriodSixTimeSlot EGPLGPSEVENTS: egprsPollingPeriodSevenTimeSlot EGPLGPEIGHTTS: egprsPollingPeriodEightTimeSlot PERSTLVPRI1: persistenceLevelPriority1 PERSTLVPRI2: persistenceLevelPriority2 PERSTLVPRI3: persistenceLevelPriority3 PERSTLVPRI4: persistenceLevelPriority4 NCC1TH: NcC1Threshold NCRARESH: NcRaReselectHysteresis NCSAMERA: NcSameRoutingArea NCTRFPSCTH: ncTrafcPSControlThreshold CRESELTHRINP: cellReselectionThresholdInput PKTMEASREPCNT: packetMeasurementReportCounter GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 830 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GTDDMURREP&CSCH3CSCH4SUP&BVCBHIPER&BVCBSPPER&BVCB- MAPER&BVCBLPER&MSBSPPER&MSBHIPER &MSBMAPER&MSBLPER&ELKADPT&BLERAVEUL&BLERAVEDL& EMFA1UNIR8PSK&EMFAP1UNIR8PSK&EMFB1UNIR8PSK&EMFCUNIR8PSK& EMFGUNIR8PSK&EMFCUNIRGMSK&EMFGUNIRGMSK&EMCSFAMA1DL& EMCSFAMAP1DL&EMCSFAMB1DL&EMCSFAMCDL&EMCSFAMGDL &IMCSULNIR8PSK&IMCSULNIRGMSK&INIMCSDL&RAENV&STGT- TLLIINF&INIBLER&SCHWEIPRI1&SCHWEIPRI2&SCHWEIPRI3&SCHWEIPRI4& EBCCHTRX&EEDGE&EGPRS&BEPAVGP&EGWSONETS& EGWSTWOTS&EGWSTHREETS&EGWSFOURTS& EGWSFIVETS&EGWSSIXTS&EGWSSEVENTS&EGWSEIGHTTS& EGPLGPONETS&EGPLGPTWOTS&EGPLGPTHREETS&EGPLGPFOURTS& EGPLGPFIVETS&EGPLGPSIXTS&EGPLGPSEVENTS&EGPLGPEIGHTTS& PERSTLVPRI1&PERSTLVPRI2&PERSTLVPRI3&PERSTLVPRI4&NCC1TH&NCRAR ESH&NCSAMERA&NCTRFPSCTH&CRESELTHRINP&PKTMEASREPCNT; GET PTPPKF BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF GET PTPPKF BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses btsmn, btsn and "ptppkfn" can be found in Appendix A. System Responses: GET PTPPKF BASICS: NAME=BTSM:btsmn/BTS:btsn/PTPPKF:ptppkfn; GET ACK: NAME: name RACODE: RoutingAreaCode RACOL: RoutingAreaColour BSCDVMA: bscountdownValueMax PKTNDEC: packetNumberDecrement PKTNINC: packetNumberIncrement PKTNMA: packetNumberMax GRXLAMI: gprsLevAccessMin GMSTXPMAC: gprsMxTxPwrMaxCch ABUTYP: accessBurstType RAARET: randomAccessRetry A30808-X3247-L230-3-7619 831 Commands Base Station Controller CML:BSC GPATH: gprsPriorityAccessThreshold GTXINT: gprsTxInterval GS: gprsSlot GMANRETS: gprsMaxNumberRetransmission GMANMSAL: gprsMaxNumberMsAllocated T3168: t3168 T3192: t3192 INICSCH: initialCodingScheme NTWCOR: networKControlOrder GCELLRESH: gprsCellReselectHysteresis C31H: c31Hysteresis C32QUAL: c32Qualifier TRESEL: tResel RARESH: routingAreaReselectHysteresis GHCSTH: gprsHierarchycalCellStructureThreshold GHCSPC: gprsHierarchycalCellStructurePriorityClass ALPHA: alphaPowerControlAlgorithm TAVGW: tAverageWeight TAVGT: AverageTime PRPBCCH: powerRedactionOnPbcch PCMECH: oowerControlMeasurementChannel NAVGI: nAverageInterference BSPBBLK: bsPbcchBlocks BPAGCHR: bsPagchBlocksReserved BPRACHR: bsPrachBlocksReserved DRXTXMA: discontinousReceptionTimerMax CACKTYP: controlAcknowledgementType GAM: gamma GASTRTH: gprsAllocationStrategyThresholds GPDPDTCHA: gprsPercentageOfDinamicPdtchAvailable QSRHPRI: qSearchPriority FDDGQO: fddGPRSQOffset GMANPRES: gprsMaxNumberPDCHRes TRFPSCTRLT: TrafficPSControlTimer NTWCREPPR: NetworkControlReportPeriodTransfer NTWCREPPIDL: networkControlReportPeriodIdle NTWCNDRXP: networkControlNonDRXPeriod CRESELTRHSOUT: cellReselectionThresholdOutput GUMTSSRHPRI: gprsUmtsSearchPriority GFDDQMI: GprsFddQmin TDDGQO: tddGprsQOffset GFDDREPQTY: GprsFddReportingQuantity GNMULBAC: gprsNMultibandCell GFDDMURREP gprsFddMultiratReporting GTDDMURREP gprsTddMultiratReporting CSCH3CSCH4SUP: codingScheme3CodingScheme4Support BVCBHIPER: bvcBucketHighPercentage 832 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BVCBSPPER: bvcBucketSizePcuPercentage BVCBMAPER: bvcBucketMaxPercentage BVCBLPER: bvcBucketLowPercentage MSBSPPER: msBucketSizePcuPercentage MSBHIPER: msBucketHighPercentage MSBMAPER: msBucketMaxPercentage MSBLPER: msBucketLowPercentage ELKADPT: enableLinkAdaptation BLERAVEUL: blockErrorRateAveragingPeriodUplink BLERAVEDL: blockErrorRateAveragingPeriodDownlink EMFA1UNIR8PSK: enMcsFamAMcs1UplinkWoutIncrRed8Psk EMFAP1UNIR8PSK: enMcsFamApMcs1UplinkWoutIncrRed8Psk EMFB1UNIR8PSK: enMcsFamBMcs1UplinkWoutIncRed8Psk EMFCUNIR8PSK: enMcsFamCUplinkWoutIncRed8Psk EMFGUNIR8PSK: enMcsFamGmskUplinkWoutIncRed8Psk EMFCUNIRGMSK: enMcsFamCUplinkWoutIncrRedGmsk EMFGUNIRGMSK: enMcsFamGmskUplinkWoutIncrRedGmsk EMCSFAMA1DL: enMcsFamAMcs1Downlink EMCSFAMAP1DL: enMcsFamAPaddingMcs1Downlink EMCSFAMB1DL: enMcsFamBMcs1Downlink EMCSFAMCDL: enMcsFamCDownlink EMCSFAMGDL: enMcsFamGmskDownlink IMCSULNIR8PSK: initialMcsUplinkWoutIncrRed8psk IMCSULNIRGMSK: initialMcsUplinkWoutIncrRedGmsk INIMCSDL: initialMcsDownlink RAENV: radioEnvironment STGTTLLIINF: storageTimeTLLIInfo INIBLER: initialBLER SCHWEIPRI1: schedulingWeightOfPriority1 SCHWEIPRI2: schedulingWeightOfPriority2 SCHWEIPRI3: schedulingWeightOfPriority3 SCHWEIPRI4: schedulingWeightOfPriority4 EBCCHTRX: egprs8pskOnBcchTrx EEDGE: enableEdge EGPRS: enableGprs BEPAVGP: bitErrorProbabilityAveragePeriod EGWSONETS: egprsWindowSizeOneTimeSlot EGWSTWOTS: egprsWindowSizeTwoTimeSlot EGWSTHREETS: egprsWindowSizeThreeTimeSlot EGWSFOURTS: egprsWindowSizeFourTimeSlot EGWSFIVETS: egprsWindowSizeFiveTimeSlot EGWSSIXTS: egprsWindowSizeSixTimeSlot EGWSSEVENTS: egprsWindowSizeSevenTimeSlot EGWSEIGHTTS: egprsWindowSizeEightTimeSlot EGPLGPONETS: egprsPollingPeriodOneTimeSlot EGPLGPTWOTS: egprsPollingPeriodTwoTimeSlot EGPLGPTHREETS: egprsPollingPeriodThreeTimeSlot A30808-X3247-L230-3-7619 833 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get PTPPKF BASICS:NAME=BTSM:0/BTS:0/PTPPKF:0; GET PTPPKF STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF GET PTPPKF STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the PTPPKF object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) EGPLGPFOURTS: egprsWindowSizeFourTimeSlot EGPLGPFIVETS: egprsPollingPeriodFiveTimeSlot EGPLGPSIXTS: egprsPollingPeriodSixTimeSlot EGPLGPSEVENTS: egprsPollingPeriodSevenTimeSlot EGPLGPEIGHTTS: egprsPollingPeriodEightTimeSlot PERSTLVPRI1: persistenceLevelPriority1 PERSTLVPRI2: persistenceLevelPriority2 PERSTLVPRI3: persistenceLevelPriority3 PERSTLVPRI4: persistenceLevelPriority4 NCC1TH: NcC1Threshold NCRARESH: NcRaReselectHysteresis NCSAMERA: NcSameRoutingArea NCTRFPSCTH: ncTrafcPSControlThreshold CRESELTHRINP: cellReselectionThresholdInput PKTMEASREPCNT: packetMeasurementReportCounter GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET PTPPKF STAT: NAME=BTSM:btsmn/BTS:btsn/PTPPKF:ptppkfn; 834 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Control Status (CTS) Unknown Status (UNK). Validity ranges of the object addresses btsmn, btsn and "ptppkfn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get PTPPKF STAT:NAME=BTSM:0/BTS:0/PTPPKF:0; GETINFO PTPPKF Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF GETINFO PTPPKF Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The states and statuses of the PTPPKF: AST, OST, AVS, PRS. 2. The BVCI number. 3. The PCU serving number. 4. The information about GPRS availability (Yes if there is at least one TRX enabled to support GPRS). 5. The bit map to know what TRX is enabled to support GPRS. 6. The number of mobile in packed mode. 7. The mean data ow load percentage. 8. The peak of the data ow load percentage. 9. The mean connected mobiles number in the last 5 minutes. 10. The peak of the connected mobiles number in the last 5 minutes. 11. The Cell Global Identier. 12. The Routing Area (RA) code. GET PTPPKF STAT ACK: Successful GET PTPPKF STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETINFO PTPPKF: NAME=BTSM:btsmn/BTS:btsn/PTPPKF:ptppkfn; A30808-X3247-L230-3-7619 835 Commands Base Station Controller CML:BSC 13. For each NSVC the following information: the NSVC instance number; the AST; the OST; the AVS; 14. For each PDT the following information: the PDT number; the UST. Validity ranges of the object addresses btsmn, btsn and "ptppkfn" can be found in Appendix A. System Responses: GETINFO REPORT PTPPKF: <BSS ID> <BTSM ID> <PTPPKF NR> 11:41:14 22/03/2001 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE PROCEDURAL STATUS: NONE BVCI (PTPPKF ABSOLUTE NR +2): 3 PCU NR: 11 GPRS AVAILABLE: TRUE GPRS TRX MAP: 1 7 20 23 MOBILE NR. IN PACKED MODE: 10 MEAN DATA FLOW LOAD: 30% PEAK DATA FLOW LOAD: 60% MEAN CONNECTED MOBILES NUMBER (LAST 5 MIN): 2 PEAK CONNECTED MOBILES NUMBER (LAST 5 MIN): 7 CELL GLOBAL ID: 123 54 765 334 RA CODE: 24 NSVC NR. ADMINISTRATIVE OPERATIONAL AVAILABILITY(MAX 16 VALUES) 0 UNLOCKED ENABLED NONE 1 LOCKED ENABLED NONE 2 UNLOCKED DISABLED OFF_LINE 3 UNLOCKED ENABLED NONE ... ... 62 UNLOCKED ENABLED NONE PDT NR USAGE 0 IDLE 1 BUSY 2 ACTIVE 3 IDLE ... ... 255 IDLE 836 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller END OF REPORT GETINFO PTPPKF NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack PTPPKF: name = PTPPKF:0 nackCause = <nack cause> Application Guidelines: None. Example of Command Execution Getinfo PTPPKF:NAME=BTSM:0/BTS:0/PTPPKF:0; GETRELATIONSHIP PTPPKF Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF GETRELATIONSHIP PTPPKF Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of the all HMOs (Hardware Managed Object) supporting the FMO functionality. For the PTPPKF object the related HMOs are the following: LICD/LICDS, EPWR, PPLD, PPCU, PWRD, MPCC, TDPC, MEMT, NTW, PPXL, PPXU and all the BTSE HMOs that implement the TRX functionality for a certain BTS. NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. GETRELATIONSHIP PTPPKF: NAME=BTSM:btsmn/BTS:btsn/PTPPKF:ptppkfn; A30808-X3247-L230-3-7619 837 Commands Base Station Controller CML:BSC For BS-2x/6x, the BTSE HMOs are: ACOM, BBSIG, CCLK, CCTRL, FTNF, FVSWR, GPSU, LI, PA, RXMUCO, RXAMOD and TPU. For BS-4x/240/241/240XL, the BTSEHMOs are: COBA, COSA, CU, DIDCTMA, DILNA, DUDCTMA, DULNA, DUVSWR, FTNFP, FVSWRP and TMA. For BS-242, the BTSE HMOs are: CA, CCINT, CCSLINK, COBA, COSA and DCREFE. For the BS-82, the BTSE HMOs are: COBA, CU, DUVSWR and DULNA. Validity ranges of the object addresses btsmn, btsn and "ptppkfn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship PTPPKF:NAME=BTSM:0/BTS:0/PTPPKF:0; GETSUBO PTPPKF Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF GETSUBO PTPPKF Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. Validity ranges of the object addresses btsmn, btsn and "ptppkfn" can be found in Appendix A. GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The object does not provide any relationship attribute. GETSUBO PTPPKF: NAME=BTSM:btsmn/BTS:btsn/PTPPKF:ptppkfn; 838 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses Application Guidelines: None. Example of Command Execution Getsubo PTPPKF:NAME=BTSM:0/BTS:0/PTPPKF:0; LOCK PTPPKF Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF LOCK PTPPKF Applicability: Phase 2. Visibility level 1. Command Description: The information about status of the cell must be notified to MSs via appropriate system information and to SGSN via block procedure. Validity ranges of the object addresses btsmn, btsn and "ptppkfn" can be found in Appendix A. System Responses: GETSUBO ACK: The output of the command can be composed by one or more pack with a maximumnumber of three subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GETSUBO NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK PTPPKF: NAME=BTSM:btsmn/BTS:btsn/PTPPKF:ptppkfn; LOCK PTPPKF ACK: LOCK PTPPKF NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_INVALID_STATUS A30808-X3247-L230-3-7619 839 Commands Base Station Controller CML:BSC Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock PTPPKF:NAME=BTSM:0/BTS:0/PTPPKF:0; 840 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SET PTPPKF Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF SET PTPPKF Applicability: Phase 2. Visibility level 2. SET PTPPKF: NAME=BTSM:btsmn/BTS:btsm/PTPPKF:ptppkfn [,RACODE=] [,RACOL=] [,BSCDVMA=] [,PKTNDEC=] [,PKTNINC=] [,PKTNMA=] [,GRXLAMI=] [,GMSTXPMAC=] [,ABUTYP=] [,RAARET=] [,GPATH=] [,GTXINT=] [,GS=] [,GMANRETS=] [,GMANMSAL=] [,T3168=] [,T3192=] [,INICSCH=] [,NTWCOR=] [,GCELLRESH=] [,C31H=] [,C32QUAL=] [,TRESEL=] [,RARESH=] [,GHCSTH=] [,GHCSPC=] [,ALPHA=] [,TAVGW=] [,TAVGT=] [,PRPBCCH=] [,PCMECH=] [,NAVGI=] [,BSPBBLK=] [,BPAGCHR=] [,BPRACHR=] [,DRXTMA=] [,CACKTYP=] [,GAM=] [,GASTRTH=] [,GPDPDTCHA=] [,QSRHPRI=] [,FDDGQO=][,GMANPRES=] [,TRFPSCTRLT=] [,NTWCREPPTR=] [,NTWCREPPIDL=] [,NTWCNDRXP=] [,CRESELTRHSOUT=] [,GUMTSSRHPRI=] [,GFDDQMI =] [,TDDGQO ][,GFDDREPQTY=] [,GNMULBAC=] [,GFDDMURREP=][,GTDDMURREP=][,CSCH3CSCH4SUP =] [,BVCBHIPER=] [,BVCBSPPER=] [,BVCBMAPER=] [,BVCBLPER=] [,MSBSPPER=] [,MSBHIPER=] [,MSBMAPER=] [,MSBLPER=] [,ELKADPT=] [,BLERAVEUL=] [,BLERAVEDL=] [,EMFA1UNIR8PSK=] [,EMFAP1UNIR8PSK=] [,EMFB1UNIR8PSK=] [,EMFCUNIR8PSK=] [,EMFGUNIR8PSK=] [,EMFCUNIRGMSK=] [,EMFGUNIRGMSK=] [,EMCSFAMA1DL=] [,EMCSFAMAP1DL=] [,EMCSFAMB1DL=] [,EMCSFAMCDL=] [,EMCSFAMGDL=] [,IMCSULNIR8PSK=] [,IMCSULNIRGMSK=] [,INIMCSDL=] [,RAENV=] [,STGTTLLIINF=] [,INIBLER=] [,SCHWEIPRI1=] [,SCHWEIPRI2=] [,SCHWEIPRI3=] [,SCHWEIPRI4=] [,EBCCHTRX=] [,EEDGE=] [,EGPRS=] [,BEPAVGP=] [,EGWSONETS=] [,EGWSTWOTS=] [,EGWSTHREETS=] [,EGWSFOURTS=] [,EGWSFIVETS=] [,EGWSSIXTS=] [,EGWSSEVENTS=] [,EGWSEIGHTTS=] [,EGPLGPONETS=] [,EGPLGPTWOTS=] [,EGPLGPTHREETS=] [,EGPLGPFOURTS=] [,EGPLGPFIVETS=] [,EGPLGPSIXTS=] [,EGPLGPSEVENTS=] [,EGPLGPEIGHTTS=] [,PERSTLVPRI1=] [,PERSTLVPRI2=] [,PERSTLVPRI3=] [,PERSTLVPRI4=] [,NCC1TH=] [,NCRARESH=] [,NCSARA=] [,NCTRFPSCTH=] [,CRESELTHRINP=] [,PKTMEASREPCNT=]; A30808-X3247-L230-3-7619 841 Commands Base Station Controller CML:BSC Command Description: This command modifies the specific parameters of the PTPPKF object class. It is used to change the configuration attributes associated to this object. Some attributes can be changed without the interruption of the service while some other needs interruption of the service. The following attributes can be changed only after PTPPKF locking, that means service interruption: RACODE, RACOL and CACKTYP (reserved for further implementation). Validity ranges of the object addresses btsmn, btsn and "ptppkfn" can be found in Appendix A. System Responses: SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command must be done in LOCKED state if the following attributes are changed: RACODE, RACOL, GPDPDTCHA. In order to set the CSCH3CSCH4SUP attribute the PTPPKF object must be in LOCKED state. The attribute EBCCHTRX can be modified only if the related PTPPKF object is in LOCKED state. The attribute EEDGEcan be modified only if the related PTPPKF object is in LOCKED state. The following attributes can be changed only if the PTPPKF object is in LOCKED state: ELKADPT, BLERAVEDL, BLERAVEUL, EMFA1UNIR8PSK, EMFAP1UNIR8PSK, EMFB1UNIR8PSK, EMFCUNIR8PSK, EMFGUNIR8PSK, EMFCUNIRGMSK, EMFGUNIRGMSK, EMCSFAMA1DL, EMCSFAMAP1DL, EMCSFAMB1DL, EMCSFAMCDL, EMCSFAMGDL, RAENV. In order to set the SCHWEIPRI1, SCHWEIPRI2, SCHWEIPRI3, SCHWEIPRI4 attributes the PTPPKF object must be in LOCKED state. In order to set the BVCBSPER, BVCBHIPER, BVCBMAPER, BVCBLPER, MSBSPER, MSBHIPER, MSBMAPER, MSBLPER attributes the PTPPKF object must be in LOCKED state. UNSUCCESSFUL_VAR_OUT_OF_RANGE The ThresholdIdleChanHV field of the GASTRTH attribute has to be lower than the ThresholdIdleChanVH field. The ThresholdIdleChanVH field of the GASTRTH attribute has to be lower than or equal to the ThresholdIdleChanEU field. INCOMP_NESWLOAD_VS_MESSAGE The CSCH3CSCH4SUP cannot be set at TRUE if the SW Version running on the superordinated BTSM belongs to BR6.0 release (see EXPSWV parameter description). 842 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BEPAVGP, EGWSONETS, EGWSEIGHTS, EGPLGPONETS, EGPLGPEIGHTS can not be set at a value different fromNULL, if the SW Version running on the superordinated BTSM object belongs to BR6.0 release (see EXPSWVparameter description). The attribute EBCCHTRX can not be set at TRUE if the SW Version running on the superordinated BTSM object belongs to BR6.0 release (see EXPSWV parameter description). The attribute EEDGE can not be set at TRUE if the SWVersion running on the superordinated BTSM object belongs to BR6.0 release (see EXPSWV parameter description). BEPAVGP, EGWSONETS, EGWSEIGHTS, EGPLGPONETS, EGPLGPEIGHTS can not be set at a value different fromNULL, if the BTSE is not of one of the following types: BS-240, BS- 240SR, BS-241, BS-241SR, BS-240XL, BS-240XLSR, BS-40, BS-41. BEPAVGP, EGWSONETS, EGWSEIGHTS, EGPLGPONETS, EGPLGPEIGHTS can not be set at NULL value, if the BTSE is of one of the following types: BS-240, BS-240SR, BS-241, BS-241SR, BS-240XL, BS-240XLSR, BS-40, BS-41. The attribute EBCCHTRX can not be set at TRUE if the BTSE is not of one of the following types: BS-240, BS-240SR, BS-241, BS-241SR, BS-240XL, BS-240XLSR, BS-40, BS-41. The attribute EEDGE can not be set at TRUE if the BTSE is not of one of the following types: BS-240, BS-240SR, BS-241, BS-241SR, BS-240XL, BS-240XLSR, BS-40, BS-41. The following attributes: EMFA1UNIR8PSK, EMFAP1UNIR8PSK, EMFB1UNIR8PSK, EMFCUNIR8PSK, EMFGUNIR8PSK, EMFCUNIRGMSK, EMFGUNIRGMSK, EMCSFAMA1DL, EMCSFAMAP1DL, EMCSFAMB1DL, EMCSFAMCDL, EMCSFAMGDL, IMCSULNIR8PSK, IMCSULNIRGMSK, INIMCSDL can not be set at a value different from NULL if the SWVersion running on the superordinated BTSM object belongs to BR6.0 release (see EXPSWV parameter description). The following attributes: EMFA1UNIR8PSK, EMFAP1UNIR8PSK, EMFB1UNIR8PSK, EMFCUNIR8PSK, EMFGUNIR8PSK, EMFCUNIRGMSK, EMFGUNIRGMSK, EMCSFAMA1DL, EMCSFAMAP1DL, EMCSFAMB1DL, EMCSFAMCDL, EMCSFAMGDL, IMCSULNIR8PSK, IMCSULNIRGMSK, INIMCSDL can not be set at a value different from NULL if the HW Version of the BTSE is different from BTS+. The following attributes: EMFA1UNIR8PSK, EMFAP1UNIR8PSK, EMFB1UNIR8PSK, EMFCUNIR8PSK, EMFGUNIR8PSK, EMFCUNIRGMSK, EMFGUNIRGMSK, EMCSFAMA1DL, EMCSFAMAP1DL, EMCSFAMB1DL, EMCSFAMCDL, EMCSFAMGDL, IMCSULNIR8PSK, IMCSULNIRGMSK, INIMCSDL can not be set at NULL value if the HW Version of the BTSE is BTS+. If the SW Version running on the superordinated BTSM object (see EXPSWV parameter description), the ELKADPT attribute must be set to FALSE. UNSUCCESSFUL_CODING_SCHEME_NOT_SUPPORTED A30808-X3247-L230-3-7619 843 Commands Base Station Controller CML:BSC In order to set CSCH3CSCH4SUP at TRUE, CSCH3CSCH4SUP in BSC object must be TRUE. In order to set CSCH3CSCH4SUP at TRUE, the PUREBBSIG44CONF attribute in BTS object must be TRUE or NULL. The INICSCH attribute cannot be set at CS3 or CS4 if the CSCH3CSCH4SUP attribute is set at FALSE and vice versa. The INICSCHattribute cannot be set to a value greater than CS2 if BIT25 of MNTBMASK has been set to 1. UNSUCCESSFUL_EDGE_NOT_SUPPORTED The attribute EEDGE can not be set at TRUE if the ESUP attribute of BSC object is set at FALSE or no TRXs in the cell have TRXMD set at EDGE. The attribute EBCCHTRX can not be set at TRUE if the related BCCH TRX has TRXMD set at GSM or the ESUP attribute of BSC object is set at FALSE. UNSUCCESSFUL_GPRS_NOT_SUPPORTED The attribute EGPRS can not be set at TRUE if no TRXs in the cell have GSUP set at TRUE. UNSUCCESSFUL_INVALID_ATTRIBUTES The attribute EGPRS can not be set at FALSE if EEDGE is set at TRUE. The attribute EEDGE can not be set at TRUE if EGPRS is set at FALSE. The attribute EEDGE can not be set at TRUE if CSCH3CSCH4SUP is set at FALSE. The following relations between the SCHWEIPRI1, SCHWEIPRI2, SCHWEIPRI3, SCHWEIPRI4 attributes must be satisfied: SCHWEIPRI1 >= SCHWEIPRI2 >= SCHWEIPRI3 >= SCHWEIPRI4. The BVCBHIPER attribute cannot be set at a value lower or equal than BVCBLPER. The MSBHIPER attribute cannot be set at a value lower or equal than MSBLPER. EGWSyTS value must be major or equal than EGWSxTS and minor or equal than EGWSzTS, where x < y< z The ELKADPT attribute cannot be set to TRUE if the NTWCARD parameter (BSC object) is set to NTWSN16. The STGTTLLINF attribute must be set to a value greater than TRFPSCTRLT. The NCTRFPSCTH attribute must be set to a value less than CRESELTHRSOUT. The NCTRFPSCTH attribute must be set to a value greater or equal than CRESELTHRINP. UNSUCCESSFUL_WRONG_MCS The IMCSULNIR8PSK chosen does not belong to the family enabled for Uplink 8PSK without Incremental Redundancy, i.e EMFA1UNIR8PSK, EMFAP1UNIR8PSK, EMFB1UNIR8PSK, EMFCUNIR8PSK, EMFGUNIR8PSK. 844 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The value of BSPBBLK, BPAGCHR and BPRACHR parameters has to be set in such a way to have at least one block of each of the following types: PBCCH, PPCH, PAGCH for DL; PRACH for UL. For instance, if BSPBBLK is set at 1 the maximum value for BPAGCHR is 9. 2. The difference between the ThresholdIdleChanVH and ThresholdIdleChanHV fields of GASTRTH parameter has to be set at a value not too much high, in order to have a real hysteresis behaviour. 3. The following relationships must be veried: NCTRFPSCTH < = CRESELTHRSOUT NCTRFPSCTH > CRESELTHRINP 4. The maximum admitted value of the GMANPRES attribute is equal to 190. When setting the value of this attribute, the operator must pay attention about how many TRXs are equipped, and how many timeslots he would like to reserve to GPRS/EGPRS services, otherwise he could lose all circuit switched trafc. For example if a BTS is equipped with two TRXs, the GMANPRES value must not be greater than 14, otherwise CS calls are not allowed in the cell (considering that at least two timeslots are used for BCCH and SDCCH channels). In this case if the operator wants to reserve statically half of the resources for GPRS/EGPRS, he has to set GMANPRES=7. Example of Command Execution Set PTPPKF:NAME=BTSM:0/BTS:0/PTPPKF:0,RACODE=1,RACOL=5,BSCDVMA=5, PKTNDEC=6,PKTNINC=7,PKTNMA=0,GRXLAMI=10,GMSTXPMAC=20,ABUTYP=0, RAARET=0,GPATH=2,GTXINT=9,GS=3,GMANRETS=2,GMANMSAL=7-9, T3166_68=3,T3192=2,INICSCH=CS1,NTWCOR=0, GCELLRESH=7,C31H=0,RARESH=6,GHCSTH=11,GHCSPC=4, ALPHA=8,TAVGW=15,TAVGT=7,PRPBCCH=12,PCMECH=0,NAVGI=9, BSPBBLK=0,BPAGCHR=5,PBRACHR=8,DRXTMA=4,CACKTYP=1, GASTRTH=10-20-20,GPDPDTCHA=0,QSRHPRI=UMDB82,FDDGQO=DB08, GMANPRES=0,TRFPSCTRLT=5, NTWCREPPTR=MSEC480, NTWCREP- PIDL=MSEC61440, NTWCNDRXP=MSEC960, CRESELTRHSOUT=85, GUMTSS- RHPRI=FALSE, GFDDQMI=MDB18, TDDGQO=DB16,GFDDREPQTY=RSCP, GNMULBAC=2, GFDDMURREP=1, GTDDMURREP=1,CSCH3CSCH4SUP=FALSE,BVCBHIPER=70, BVCBSPPER=PER200,BVCBMAPER=PER100,BVCBLPER=PER60, MSBSPPER=PER200,MSBHIPER=PER70,MSBMAPER=PER100, MSBLPER=PER60,ELKADPT=FALSE,BLERAVEUL=UNIT400, BLERAVEDL=UNIT400,EMFA1UNIR8PSK=TRUE,EMFA1UNIR8PSK=FALSE, The IMCSULNIRGMSK chosen does not belong to the family enabled for GSMK without Incremental Redundancy, i.e. EMFCUNIRGMSK and EMFGUNIRGMSK. The INIMCSDL chosen does not belong to the family enabled for EMCSFAMA1DL, i.e. EMCSFAMAP1DL, EMCSFAMB1DL, EMCSFAMCDL, EMCSFAMGDL. UNSUCCESSFUL_HOPPING_SYSTEM_INCONSISTENT If the BCCH is involved in a BBHOP hopping law and the BCCH TRX has TRXMD=EDGE, EBCCHTRX cannot be set at FALSE. A30808-X3247-L230-3-7619 845 Commands Base Station Controller CML:BSC EMFB1UNIR8PSK=FALSE,EMFCUNIR8PSK=FALSE,EMFGUNIR8PSK=FALSE, EMFCUNIRGMSK=FALSE,EMFGUNIRGMSK=TRUE,EMCSFAMA1DL=TRUE, EMCSFAMAP1DL=FALSE,EMCSFAMB1DL=FALSE,EMCSFAMCDL=FALSE, EMCSFAMGDL=FALSE,IMCSULNIR8PSK=MCS6,IMCSULNIRGMSK=MCS3, INIMCSDL=MCS9,RAENV=HIGHDIV,STGTTLLIINF=60,INIBLER=PER20, SCHWEIPRI1=7,SCHWEIPRI2=6,SCHWEIPRI3=5,SCHWEIPRI4=2, EBCCHTRX=FALSE,EEDGE=TRUE,EGPRS=TRUE,BEPAVGP=5, EGWSONETS=192,EGWSTWOTS=256,EGWSTHREETS=384,EGWSFOURTS=512, EGWSFIVETS=640,EGWSSIXTS=768,EGWSSEVENTS=896, EGWSEIGHTTS=1024,EGPLGPONETS=16,EGPLGPTWOTS=16, EGPLGPTHREETS=16,EGPLGPFOURTS=16,EGPLGPFIVETS=16, EGPLGPSIXTS=16,EGPLGPSEVENTS=16,EGPLGPEIGHTTS=16, PERSTLVPRI1=5,PERSTLVPRI2=5,PERSTLVPRI3=5,PERSTLVPRI4=5, NCC1TH=DB03,NCRARESH=DB00,NCSAMERA=TRUE, NCTRFPSCTH=75, CRESELTHRINP=66, PKTMEASREPCNT=1; UNLOCK PTPPKF Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF UNLOCK PTPPKF Applicability: Phase 2. Visibility level 1. Command Description: This command removes the operator block and the unit remains in the operational state as it is at the moment of the command. Validity ranges of the object addresses btsmn, btsn and "ptppkfn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock PTPPKF:NAME=BTSM:0/BTS:0/PTPPKF:0; UNLOCK PTPPKF: NAME=BTSM:btsmn/BTS:btsn/PTPPKF:ptppkfn; UNLOCK ACK: Successful UNLOCK NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_STATUS 846 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PTPPKFTD The PTPPKFTD functional object represents the TD-SCDMA packet switched service in a cell. In TD-SCDMA system, for point to point packet data transfer, a cell is identified by a BVCI, so there is a one to one relation between cell and BVCI. CREATE PTPPKFTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTDBTSTDPTPPKFTD CREATE PTPPKFTD Applicability: Phase 2. Visibility level 2. Command Description: This command creates an instance of the PTPPKFTD object class. It can be done only if the super-ordinate BTSTD and all the necessary NSVCs (at least one) are created. Creation of PTPPKFTD object means allowing TD-SCDMA packet switched service in a specific cell. The information to the mobile about the packet switched service in the network are provided via systeminformation. The status at creation will be Locked-Disabled/Offline. On the created PTPPKFTD, a BVCI reset procedure is performed toward SGSN. After a positive termination of the procedure, the PTPPKFTD shall became Locked-Enabled and a block procedure is necessary to reflect the locked condition. Validity ranges of the object addresses btsmtdn, btstdn and "ptppkftdn" can be found in Appendix A. System Responses: CREATE PTPPKFTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/PTPPKFTD:ptpp- kftdn, RACODE= ,RACOL= [,BSCDVMATD=] [,PKTNDECTD=] PKTNINCTD [,PKTNMATD=] [,PKRXP- LUPDESTD=] [,TPPATHTD=] [,TPMANUEALTD=] [,T3168TD=] [,T3192TD=] [,T3204TD=] [,PKUE=][,T3146TD=] [,INICSCHTD=] [,INIMODETD=] [,TPMANAUUUETD=] [,NTWCORTD=] [,DRXTMATD=] [,ALPHATD=] [,TAVGWTD=] [,TAVGTTD=] [,NAVGITD=] [,TPMASTATIME=] [,TPUECHTS=] [,TPMAAUUSETRES=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED A30808-X3247-L230-3-7619 847 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Create PTPPKFTD:NAME=BTSMTD:0/BTSTD:0/PTPPKFTD:0,RACODE=1, RACOL=5,BSCDVMATD=5, PKTNDECTD=6,PKTNINCTD=7,PKTNMATD=0, PKRXPLUPDESTD=[-100],TPPATHTD=PKAAP4,TPMANUEALTD=15, T3168TD=2,T3192TD=WAIT_105bp,T3204TD=N_0040_ms, PKUE=WAIT_016BP,T3146TD=0,INICSCHTD=CS2,INIMODETD=Mode1, TPMANA- UUUETD=10-10,NTWCORTD=NC0,DRXTMATD=7, ALPHATD=8,TAVGWTD=15,TAVGTTD=7, NAVGITD=9, TPMASTA- TIME=100,TPUECHTS=WEIGHT_50,TPMAAUUSETRES=50; DELETE PTPPKFTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTDBTSTDPTPPKFTD DELETE PTPPKFTD Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a previously created instance of the PTPPKFTD object class. It can be done only if the object is in Locked state. The appropriate system information shall be sent on Um interface to inform the mobile about availability of the service. Because of also SGSN knows the BVCI connected to this object, appropriate actions to inform it about new PTPPKFTD configurations should be taken by BSC. Validity ranges of the object addresses btsmtdn, btstdn and "ptppkftdn" can be found in Appendix A. System Responses: The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The relevant BTSTD object instance must be already created. At least one PCUTD instance must already exist. At least one NSVC on a PCUTD must be created. DELETE PTPP- KFTD NAME=BTSMTD:btsmtdn/BTSTD:btstdn/PTPPKFTD:ptppkftdn; DELETE ACK: SUCCESSFUL DELETE NACK: NACK CAUSES: 848 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Delete PTPPKFTD:NAME=BTSMTD:0/BTSTD:0/PTPPKFTD:0; GET PTPPKFTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTDBTSTDPTPPKFTD GET PTPPKFTD Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameter values of an instance of the PTPPKFTD object class. Validity ranges of the object addresses btsmtdn, btstdn and "ptppkftdn" can be found in Appendix A. System Responses: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a PTPPKFTD, the relative object instance must be in LOCKED state. GET PTPPKFTD NAME=BTSMTD:btsmtdn/BTSTD:btstdn/PTPPKFTD:ptppk- ftdn [,REQATTL=RACODE ,RACOL, BSCDVMATD, PKTNDECTD, PKTNINCTD, PKTNMATD, PKRXPLUP- DESTD, TPPATHTD, TPMANUEALTD, T3168TD, T3192TD, T3204TD, PKUE, T3146TD, INICSCHTD, INIMODETD, TPMANAUUUETD, NTWCORTD, DRXTMATD, ALPHATD, TAVGWTD, TAVGTTD, NAVGITD, TPMASTATIME, TPUECHTS, TPMAAUUSETRES]; GET ACK: NAME: name RACODE: RoutingAreaCode RACOL: RoutingAreaColour BSCDVMATD: bscountdownValueMaxTD PKTNDECTD: packetNumberDecrementTD PKTNINCTD: packetNumberIncrementTD PKTNMATD: packetNumberMaxTD PKRXPLUPDESTD: packetRXPowerLevUplinkDesTD A30808-X3247-L230-3-7619 849 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get PTPPKFTD:NAME=BTSMTD:0/BTSTD:0/PTPPKFTD:0,REQATTL=RACODE& RACOL&BSCDVMATD&PKTNDECTD&PKTNINCTD&PKTNMATD& PKRXPLUPDESTD&TPPATHTD&TPMANUEALTD&T3168TD&T3192TD&T3204TD& PKUE&T3146TD&INICSCHTD&INIMODETD&TPMANAUUUETD& NTWCORTD&DRXTMATD&ALPHATD&TAVGWTD&TAVGTTD&NAVGITD& TPMASTATIME&TPUECHTS&TPMAAUUSETRES; GET PTPPKFTD BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTDBTSTDPTPPKFTD GET PTPPKFTD BASICS TPPATHTD: tdprsPriorityAccessThresholdTD TPMANUEALTD tdprsSMAXUEALLOCATEDTD T3168TD: t3168TD T3192TD: t3192TD T3204TD: t3204TD PKUE: pkUE T3146TD: t3146TD INICSCHTD: initialCodingSchemeTD INIMODETD: initialModeTD TPMANAUUUETD: tdprsMaxAUUsetUETD NTWCORTD: networKControlOrderTD DRXTXMATD: discontinousReceptionTimerMaxTD ALPHATD: alphaPowerControlAlgorithmTD TAVGWTD: tAverageWeightTD TAVGTTD: AverageTimeTD NAVGTDI: nAverageInterferenceTD TPMASTATIME TdprsMaxStartingTime TPUECHTS TdprsUEChangeTimeslot TPMAAUUSETRES: TdprsMaxAUUsetReserved GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET PTPPKFTD BASICS: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/PTPP- KFTD:ptppkftdn; 850 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses btsmtdn, btstdn and "ptppkftdn" can be found in Appendix A. System Responses: Application Guidelines: None. GET ACK: NAME: name RACODE: RoutingAreaCode RACOL: RoutingAreaColour BSCDVMATD: bscountdownValueMaxTD PKTNDECTD: packetNumberDecrementTD PKTNINCTD: packetNumberIncrementTD PKTNMATD: packetNumberMaxTD PKRXPLUPDESTD: packetRXPowerLevUplinkDesTD TPPATHTD: tdprsPriorityAccessThresholdTD TPMANUEALTD tdprsSMAXUEALLOCATEDTD T3168TD: t3168TD T3192TD: t3192TD T3204TD: t3204TD PKUE: pkUE T3146TD: t3146TD INICSCHTD: initialCodingSchemeTD INIMODETD: initialModeTD TPMANAUUUETD: tdprsMaxAUUsetUETD NTWCORTD: networKControlOrderTD DRXTXMATD: discontinousReceptionTimerMaxTD ALPHATD: alphaPowerControlAlgorithmTD TAVGWTD: tAverageWeightTD TAVGTTD: AverageTimeTD NAVGTDI: nAverageInterferenceTD TPMASTATIME TdprsMaxStartingTime TPUECHTS TdprsUEChangeTimeslot TPMAAUUSETRES: TdprsMaxAUUsetReserved GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 851 Commands Base Station Controller CML:BSC Example of Command Execution Get PTPPKFTD BASICS:NAME=BTSMTD:0/BTSTD:0/PTPPKFTD:0; GET PTPPKFTD STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTDBTSTDPTPPKFTD GET PTPPKFTD STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the PTPPKFTD object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). Validity ranges of the object addresses btsmtdn, btstdn and "ptppkftdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get PTPPKFTD STAT:NAME=BTSMTD:0/BTSTD:0/PTPPKFTD:0; GET PTPPKFTD STAT: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/PTPPKFTD:ptppk- ftdn; GET PTPPKFTD STAT ACK: Successful GET PTPPKFTD STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 852 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETINFO PTPPKFTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTDBTSTDPTPPKFTD GETINFO PTPPKFTD Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The states and statuses of the PTPPKFTD: AST, OST, AVS, PRS. 2. The BVCI number. 3. The PCUTD serving number. 4. The number of mobile in packed mode. 5. The mean data ow load percentage. 6. The peak of the data ow load percentage. 7. The mean connected mobiles number in the last 5 minutes. 8. The peak of the connected mobiles number in the last 5 minutes. 9. The Cell Global Identier. 10. The Routing Area (RA) code. 11. For each NSVC the following information: the NSVC instance number; the AST; the OST; the AVS; 12. For each PDT the following information: the PDT number; the UST. Validity ranges of the object addresses btsmtdn, btstdn and "ptppkftdn" can be found in Appendix A. System Responses: GETINFO REPORT PTPPKFTD: <BSS ID> <BTSMTD ID> <PTPPKFTD NR> 11:41:14 22/03/2001 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE PROCEDURAL STATUS: NONE BVCI (PTPPKF ABSOLUTE NR +2): 3 PCUTD NR: 11 MOBILE NR. IN PACKED MODE: 10 GETINFO PTPPKFTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/PTPPKFTD:ptppk- ftdn; A30808-X3247-L230-3-7619 853 Commands Base Station Controller CML:BSC MEAN DATA FLOW LOAD: 30% PEAK DATA FLOW LOAD: 60% MEAN CONNECTED MOBILES NUMBER (LAST 5 MIN): 2 PEAK CONNECTED MOBILES NUMBER (LAST 5 MIN): 7 CELL GLOBAL ID: 123 54 765 334 RA CODE: 24 NSVC NR. ADMINISTRATIVE OPERATIONAL AVAILABILITY(MAX 16 VALUES) 0 UNLOCKED ENABLED NONE 1 LOCKED ENABLED NONE 2 UNLOCKED DISABLED OFF_LINE 3 UNLOCKED ENABLED NONE ... ... 62 UNLOCKED ENABLED NONE PDT NR USAGE 0 IDLE 1 BUSY 2 ACTIVE 3 IDLE ... ... 255 IDLE END OF REPORT GETINFO PTPPKFTD NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack PTPPKFTD: name = PTPPKFTD:0 nackCause = <nack cause> Application Guidelines: None. Example of Command Execution Getinfo PTPPKFTD:NAME=BTSMTD:0/BTSTD:0/PTPPKFTD:0; NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. 854 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETRELATIONSHIP PTPPKFTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTDBTSTDPTPPKFTD GETRELATIONSHIP PTPPKFTD Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of the all HMOs (Hardware Managed Object) supporting the FMO functionality. For the PTPPKFTD object the related HMOs are the following: LICD/LICDS, EPWR, PPXP, PWRD, MPCC, TDPC, MEMT, NTW, and all the BTSE HMOs that implement the TRXTD functionality for the BTSC. Validity ranges of the object addresses btsmtdn, btstdn and "ptppkftdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship PTPPKFTD:NAME=BTSMTD:0/BTSTD:0/PTPPKFTD:0; GETRELATIONSHIP PTPPKFTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/PTPPKFTD:ptppk- ftdn; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The object does not provide any relationship attribute. A30808-X3247-L230-3-7619 855 Commands Base Station Controller CML:BSC GETSUBO PTPPKFTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTDBTSTDPTPPKFTD GETSUBO PTPPKFTD Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. Validity ranges of the object addresses btsmtdn, btstdn and "ptppkftdn" can be found in Appendix A. System Responses Application Guidelines: None. Example of Command Execution Getsubo PTPPKFTD:NAME=BTSMTD:0/BTSTD:0/PTPPKFTD:0; LOCK PTPPKFTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTDBTSTDPTPPKFTD LOCK PTPPKFTD Applicability: Phase 2. GETSUBO PTPP- KFTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/PTPPKFTD:ptppk- ftdn; GETSUBO ACK: The output of the command can be composed by one or more pack with a maximumnumber of three subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GETSUBO NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK PTPPKFTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/PTPPKFTD:ptppk- ftdn; 856 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Visibility level 1. Command Description: The information about status of the cell must be notified to UEs via appropriate system information and to SGSN via block procedure. Validity ranges of the object addresses btsmtdn, btstdn and "ptppkftdn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock PTPPKFTD:NAME=BTSMTD:0/BTSTD:0/PTPPKFTD:0; SET PTPPKFTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTDBTSTDPTPPKFTD SET PTPPKFTD Applicability: Phase 2. Visibility level 2. LOCK PTPPKFTD ACK: LOCK PTPPKFTD NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_INVALID_STATUS SET PTPPKFTD: NAME=BTSMTD:btsmtdn/BTSTD:btsmtdn/PTPP- KFTD:ptppkftdn [RACODE=] ,[RACOL=] [,BSCDVMATD=] [,PKTNDECTD=] PKTNINCTD [,PKTNMATD=] [,PKRXP- LUPDESTD=] [,TPPATHTD=] [,TPMANUEALTD=] [,T3168TD=] [,T3192TD=] [,T3204TD=] [,PKUE=] [,T3146TD=] [,INICSCHTD=] [,INIMODETD=] [,TPMANAU- UUETD=] [,NTWCORTD=] [,DRXTMATD=] [,ALPHATD=] [,TAVGWTD=] [,TAVGTTD=] [,NAVGITD=] [,TPMASTATIME=] [,TPUECHTS=] [,TPMAAUUSETRES=]; A30808-X3247-L230-3-7619 857 Commands Base Station Controller CML:BSC Command Description: This command modifies the specific parameters of the PTPPKFTD object class. It is used to change the configuration attributes associated to this object. Some attributes can be changed without the interruption of the service while some other needs interrup- tion of the service. The following attributes can be changed only after PTPPKFTD locking, that means service interruption: RACODE and RACOL. Validity ranges of the object addresses btsmtdn, btstdn and "ptppkftdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Set PTPPKFTD:NAME=BTSMTD:0/BTSTD:0/PTPPKFTD:0,RACODE=1, RACOL=5,BSCDVMATD=5, PKTNDECTD=6,PKTNINCTD=7,PKTNMATD=0, PKRXPLUPDESTD=[-100],TPPATHTD=PKAAP4,TPMANUEALTD=15, T3168TD=2,T3192TD=WAIT_105bp,T3204TD=N_0040_ms, PKUE=WAIT016BP,T3146TD=0,INICSCHTD=CS2,INIMODETD=Mode1, TPMANAU- UUETD=10-10,NTWCORTD=NC0,DRXTMATD=7, ALPHATD=8,TAVGWTD=15,TAVGTTD=7, NAVGITD=9, TPMASTA- TIME=100,TPUECHTS=WEIGHT_50,TPMAAUUSETRES=50; UNLOCK PTPPKFTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTDBTSTDPTPPKFTD UNLOCK PTPPKFTD Applicability: Phase 2. Visibility level 1. SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The following attributes can be changed only if the PTPPKFTD object is in LOCKED state: RACODE, RACOL, TMASTATIME, TPUECHTS, TPMAAUUSETRES. UNLOCK PTPPKFTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/PTPPKFTD:ptppk- ftdn; 858 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command removes the operator block and the unit remains in the operational state as it is at the moment of the command. Validity ranges of the object addresses btsmtdn, btstdn and "ptppkftdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock PTPPKFTD:NAME=BTSMTD:0/BTSTD:0/PTPPKFTD:0; UNLOCK ACK: Successful UNLOCK NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_STATUS A30808-X3247-L230-3-7619 859 Commands Base Station Controller CML:BSC PWRC The PWRCobject represents the parameters used in the power control algorithm. There is one instance for each cell controlled by the BSC. GET PWRC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PWRC GET PWRC Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the attributes of the powerControl object, modeling the power control algorithm used with a MS/BTS and containing the attributes which are generic to any power control algorithm. Validity ranges of the object addresses btsmn, "btsn" and pwrcn can be found in Appendix A. System Responses: GET PWRC: NAME=BTSM:btsmn/BTS:btsn/PWRC:pwrcn [,REQATTL= EBSPWRC, EMSPWRC, PWRINCSS, PWREDSS, PWRCONF, PCONINT, PAVRLEV, PAVRQUAL, LOWTLEVD, UPTLEVD, LOWTLEVU, UPTLEVU, LOWTQUAD, UPTQUAD, LOWTQUAU, UPTQUAU, RDLNKTBS, EPWCRLFW, PCRLFTH, EBSPWCR, LOWTQUAMRDL, LOWTQUAMRUL, UPTQUAMRDL, UPTQUAMRUL, SG1PCPAR, SG2PCPAR, SG3PCPAR, SG4PCPAR, SG5PCPAR, SG6PCPAR, SG7PCPAR, SG8PCPAR, SG9PCPAR, SG10PCPAR, SG11PCPAR, SG12PCPAR, SG13PCPAR, SG14PCPAR, PCMBSTXPRL]; GET ACK: NAME:name EBSPWRC:enableBsPowerContro EMSPWRC:enableMsPowerContro PWRINCSS:powerIncrStepSize PWREDSS:powerRedStepSize PWRCONF:powerConfirm PCONINT:powerControlInterva PAVRLEV:pcAveragingLev PAVRQUAL:pcAveragingQual LOWTLEVD:pcLowerThresholdLevDL UPTLEVD:pcUpperThresholdLevDL 860 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller LOWTLEVU:pcLowerThresholdLevUL UPTLEVU:pcUpperThresholdLevUL LOWTQUAD:pcLowerThresholdQualDL UPTQUAD:pcUpperThresholdQualDL LOWTQUAU:pcLowerThresholdQualUL UPTQUAU:pcUpperThresholdQualUL RDLNKTBS:radioLinkTimeoutBs EPWCRLFW:enablePowerControlRLFW PCRLFTH:pcRLFThreshold EBSPWCR:enableBsPwrCorrection LOWTQUAMRDL:pcLowerThresQualAMRDL LOWTQUAMRUL:pcLowerThresQualAMRUL UPTQUAMRDL:pcUpperThresQualAMRDL UPTQUAMRUL:pcUpperThresQualAMRUL SG1PCPAR:sg1PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresholdQualDL PcLowerThresholdQualUL PcUpperThresholdQualDL PcUpperThresholdQualUL SG2PCPAR:sg2PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresholdQualDL PcLowerThresholdQualUL PcUpperThresholdQualDL PcUpperThresholdQualUL SG3PCPAR:sg3PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL A30808-X3247-L230-3-7619 861 Commands Base Station Controller CML:BSC PcUpperThresholdLevUL PcRLFThreshold PcLowerThresholdQualDL PcLowerThresholdQualUL PcUpperThresholdQualDL PcUpperThresholdQualUL SG4PCPAR:sg4PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresholdQualDL PcLowerThresholdQualUL PcUpperThresholdQualDL PcUpperThresholdQualUL SG5PCPAR:sg5PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresholdQualDL PcLowerThresholdQualUL PcUpperThresholdQualDL PcUpperThresholdQualUL SG6PCPAR:sg6PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresholdQualDL PcLowerThresholdQualUL PcUpperThresholdQualDL PcUpperThresholdQualUL SG7PCPAR:sg7PowerControlParms EnableBSPowerControl 862 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresholdQualDL PcLowerThresholdQualUL PcUpperThresholdQualDL PcUpperThresholdQualUL SG8PCPAR:sg8PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresholdQualDL PcLowerThresholdQualUL PcUpperThresholdQualDL PcUpperThresholdQualUL SG9PCPAR:sg9PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresholdQualDL PcLowerThresholdQualUL PcUpperThresholdQualDL PcUpperThresholdQualUL SG10PCPAR:sg10PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresholdQualDL A30808-X3247-L230-3-7619 863 Commands Base Station Controller CML:BSC PcLowerThresholdQualUL PcUpperThresholdQualDL PcUpperThresholdQualUL SG11PCPAR:sg11PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresQualAMRDL PcLowerThresQualAMRUL PcUpperThresQualAMRDL PcUpperThresQualAMRUL SG12PCPAR:sg12PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresQualAMRDL PcLowerThresQualAMRUL PcUpperThresQualAMRDL PcUpperThresQualAMRUL SG13PCPAR:sg13PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresQualAMRDL PcLowerThresQualAMRUL PcUpperThresQualAMRDL PcUpperThresQualAMRUL SG14PCPAR:sg14PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL 864 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get PWRC:NAME=BTSM:0/BTS:0/PWRC:0,REQATTL=EBSPWRC&EMSPWRC& PWRINCSS&PWREDSS&PWRCONF&PCONINT&PAVRLEV&PAVRQUAL& LOWTLEVD&UPTLEVD&LOWTLEVU&UPTLEVU&LOWTQUAD&UPTQUAD& LOWTQUAU&UPTQUAU&RDLNKTBS&EPWCRLFW&PCRLFTH&EBSPWCR& LOWTQUAMRDL&LOWTQUAMRUL&UPTQUAMRDL&UPTQUAMRUL& SG1PCPAR&SG2PCPAR&SG3PCPAR&SG4PCPAR&SG5PCPAR&SG6PCPAR& SG7PCPAR&SG8PCPAR&SG9PCPAR&SG10PCPAR&SG11PCPAR& SG12PCPAR&SG13PCPAR&SG14PCPAR&PCMBSTXPRL; GET PWRC BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PWRC GET PWRC BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses btsmn, "btsn" and pwrcn can be found in Appendix A. PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresQualAMRDL PcLowerThresQualAMRUL PcUpperThresQualAMRDL PcUpperThresQualAMRUL PCMBSTXPRL:pcMaxBsTxPowerRedLev GET NACK: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET PWRC BASICS: NAME=BTSM:btsmn/BTS:btsnPWRC:pwrcn; A30808-X3247-L230-3-7619 865 Commands Base Station Controller CML:BSC System Responses: GET ACK: NAME: name EBSPWRC: enableBsPowerControl EMSPWRC: enableMsPowerControl PWRINCSS powerIncrStepSize PWREDSS: powerRedStepSize PWRCONF: powerConfirm PCONINT: powerControlInterval PAVRLEV: pcAverangingLev PAVRQUAL: pcAverangingQual LOWTLEVD: pcLowerThresholdLevDL UPTLEVD: pcUpperThresholdLevDL LOWTLEVU: pcLowerThresholdLevUL UPTLEVU: pcUpperThresholdLevUL LOWTQUAD: pcLowerThresholdQualDL UPTQUAD: pcUpperThresholdQualDL LOWTQUAU: pcLowerThresholdQualUL UPTQUAU: pcUpperThresholdQualUL RDLNKTBS: radioLinkTimeoutBs EPWCRLFW: enablePowerControlRLFW PCRLFTH: pcRLFThreshold EBSPWCR: enableBsPwrCorrection LOWTQUAMRDL:pcLowerThresQualAMRDL LOWTQUAMRUL:pcLowerThresQualAMRUL UPTQUAMRDL:pcUpperThresQualAMRDL UPTQUAMRUL:pcUpperThresQualAMRUL SG1PCPAR:sg1PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresholdQualDL PcLowerThresholdQualUL PcUpperThresholdQualDL PcUpperThresholdQualUL SG2PCPAR:sg2PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL 866 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PcUpperThresholdLevUL PcRLFThreshold PcLowerThresholdQualDL PcLowerThresholdQualUL PcUpperThresholdQualDL PcUpperThresholdQualUL SG3PCPAR:sg3PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresholdQualDL PcLowerThresholdQualUL PcUpperThresholdQualDL PcUpperThresholdQualUL SG4PCPAR:sg4PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresholdQualDL PcLowerThresholdQualUL PcUpperThresholdQualDL PcUpperThresholdQualUL SG5PCPAR:sg5PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresholdQualDL PcLowerThresholdQualUL PcUpperThresholdQualDL PcUpperThresholdQualUL SG6PCPAR:sg6PowerControlParms EnableBSPowerControl A30808-X3247-L230-3-7619 867 Commands Base Station Controller CML:BSC EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresholdQualDL PcLowerThresholdQualUL PcUpperThresholdQualDL PcUpperThresholdQualUL SG7PCPAR:sg7PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresholdQualDL PcLowerThresholdQualUL PcUpperThresholdQualDL PcUpperThresholdQualUL SG8PCPAR:sg8PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresholdQualDL PcLowerThresholdQualUL PcUpperThresholdQualDL PcUpperThresholdQualUL SG9PCPAR:sg9PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresholdQualDL 868 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PcLowerThresholdQualUL PcUpperThresholdQualDL PcUpperThresholdQualUL SG10PCPAR:sg10PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresholdQualDL PcLowerThresholdQualUL PcUpperThresholdQualDL PcUpperThresholdQualUL SG11PCPAR:sg11PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresQualAMRDL PcLowerThresQualAMRUL PcUpperThresQualAMRDL PcUpperThresQualAMRUL SG12PCPAR:sg12PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresQualAMRDL PcLowerThresQualAMRUL PcUpperThresQualAMRDL PcUpperThresQualAMRUL SG13PCPAR:sg13PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL A30808-X3247-L230-3-7619 869 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get PWRC BASICS:NAME=BTSM:0/BTS:0/PWRC:0; PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresQualAMRDL PcLowerThresQualAMRUL PcUpperThresQualAMRDL PcUpperThresQualAMRUL SG14PCPAR:sg14PowerControlParms EnableBSPowerControl EnableMSPowerControl EnablePowerControlRLFW PcLowerThresholdLevDL PcLowerThresholdLevUL PcUpperThresholdLevDL PcUpperThresholdLevUL PcRLFThreshold PcLowerThresQualAMRDL PcLowerThresQualAMRUL PcUpperThresQualAMRDL PcUpperThresQualAMRUL PCMBSTXPRL: pcMaxBsTxPowerRedLev GET NACK: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 870 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SET PWRC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PWRC SET PWRC Applicability: Phase 2. Visibility level 2. Command Description: This command sets the attributes of the powerControl object, modeling the power control algorithmused with a MS/BTS and containing the attributes which are generic to any power control algorithm. Validity ranges of the object addresses btsmn, "btsn" and pwrcn can be found in Appendix A. System Responses: SET PWRC: NAME=BTSM:btsmn/BTS:btsn/PWRC:pwrcn [,EBSPWRC=] [,EMSPWRC=] [,PWRINCSS=] [,PWREDSS=] [,PWRCONF=] [,PCONINT=] [,PAVRLEV=] [,PAVRQUAL=] [,LOWTLEVD=] [,UPTLEVD=] [,LOWTLEVU=] [,UPTLEVU=] [,LOWTQUAD=] [,UPTQUAD=] [,LOWTQUAU=] [,UPTQUAU=] [,RDLNKTBS=] [,EPWCRLFW=] [,PCRLFTH=] [,EBSPWCR=] [,LOWTQUAMRDL=] [,LOWTQUAMRUL=] [,UPTQUAMRDL=] [,UPTQUAMRUL=] [,SG1PCPAR=] [,SG2PCPAR=] [,SG3PCPAR=] [,SG4PCPAR=] [,SG5PCPAR=] [,SG6PCPAR=] [,SG7PCPAR=] [,SG8PCPAR=] [,SG9PCPAR=] [,SG10PCPAR=] [,SG11PCPAR=] [,SG12PCPAR=] [,SG13PCPAR=] [,SG14PCPAR=] [,PCMBSTXPRL=]; SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_VAR_OUT_OF_RANGE - the attribute RDLNKTBS must be a multiple of 4. - the following inequality must be satisfied: PCRLFTH < RDLNKTBS. For every SGXPCPAR, X = 1..14: If SGXPCPAR is different from NULL value, the following inequality must be satisfied: SGXPCPAR.pcRLFThreshold < RDLNKTBS. A30808-X3247-L230-3-7619 871 Commands Base Station Controller CML:BSC Application Guidelines: 1. When the BS power control is enabled (EBSPWRCattribute) the following attributes are relevant: 2. When the MS power control is enabled (EMSPWRC attribute) the following attributes are relevant: 3. When the MS and BS power control procedure due to radio link failure warning is enabled (EPWCRLFW attribute) the following attributes are relevant: INCOMP_NESWLOAD_VS_MESSAGE If the SW Version running on the superordinate BTSM object belongs to BR7.0 release (see EXPSWV parameter description) the NULL value is not allowed for the new parameter PCMBSTXPRL. If the SW Version running on the superordinate BTSM object belongs to BR6.0 release (see EXPSWV parameter description) the only value allowed for the new parameter PCMBSTXPRL is NULL. If the SW Version running on the superordinate BTSM object belongs to BR6.0 release (see EXPSWV parameter description) the EBSPWRC and EMSPWRCattributes can assume only DISABLEDand CLASSICvalues; ADAPTIVE value is not accepted. When the SGXPCPAR attribute, X = 1..14, is different from NULL, SGXPCPAR elds override the unspecic attributes shared among service groups, as shown in Appendix C. For every SGXPCPAR, X = 1..14: the attribute must be set at NULL value if the Expected SW Version (see EXPSWV parameter description) belongs to BR6.0 release. powerIncrStepSize PWRC:PWRINCSS powerRedStepSize PWRC:PWREDSS pcAveragingLev PWRC:PAVRLEV pcAveragingQual PWRC:PAVRQUAL pcLowerThresholdLevDL PWRC:LOWTLEVD pcLowerThresholdQualDL PWRC:LOWTQUAD pcUpperThresholdLevDL PWRC:UPTLEVD pcUpperThresholdQualDL PWRC:UPTQUAD powerControlInterval PWRC:PCONINT powerConfirm PWRC:PWRCONF powerIncrStepSize PWRC:PWRINCSS powerRedStepSize PWRC:PWREDSS pcAveragingLev PWRC:PAVRLEV pcAveragingQual PWRC:PAVRQUAL pcLowerThresholdLevUL PWRC:LOWTLEVU pcLowerThresholdQualUL PWRC:LOWTQUAU pcUpperThresholdLevUL PWRC:UPTLEVU pcUpperThresholdQualUL PWRC:UPTQUAU 872 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 4. Due to the mapping averaged RXQUAL <-> C/I (see Tab. 6.15), the following parameters should not exceed 20 dB or be less than 1 dB: LOWTQUAMRDL, LOWTQUAMRUL, UPTQUAMRDL, UPTQUAMRUL. Any setting above 20 dB will not be rejected by the system, but the related power control process will be affected consequently, as the related threshold will never be reached. 5. For every SGXPCPAR, X = 1..14: if at least one of the SGXPCPAR attribute elds is set at a valid value, also all the other attribute elds must be set at a valid value. Example of Command Execution Set PWRC:NAME=BTSM:0/BTS:0/PWRC:0,EBSPWRC=TRUE,EMSPWRC=TRUE, PWRINCSS=db4,PWREDSS=db2,PWRCONF=31,PCONINT=31,PAVRLEV=31-3, PAVRQUAL=31-3,LOWTLEVD=63,UPTLEVD=63, LOWTLEVU=63,UPTLEVU=63, LOWTQUAD=7,UPTQUAD=7,LOWTQUAU=7,UPTQUAU=7, RDLNKTBS=64, EPWCRLFW=TRUE,PCRLFTH=64,EBSPWCR=FALSE,LOWTQUAMRDL=1, LOWTQUAMRUL=2,UPTQUAMRDL=3,UPTQUAMRUL=4, SG1PCPAR=CLASSIC-CLASSIC-TRUE-20-15-20-5-10-5-5-5-5, SG2PCPAR=CLASSIC-CLASSIC-TRUE-20-15-20-5-10-4-4-4-4, SG3PCPAR=CLASSIC-CLASSIC-TRUE-20-12-20-5-10-4-4-4-4, SG4PCPAR=CLASSIC-CLASSIC-TRUE-20-12-20-5-10-6-6-6-6, SG5PCPAR=CLASSIC-CLASSIC-TRUE-18-12-20-5-10-4-4-4-4, SG6PCPAR=CLASSIC-CLASSIC-TRUE-21-12-20-5-10-4-4-4-4, SG7PCPAR=CLASSIC-CLASSIC-TRUE-21-12-20-5-10-3-3-3-3, SG8PCPAR=CLASSIC-CLASSIC-TRUE-21-14-20-5-10-3-3-3-3, SG9PCPAR=CLASSIC-CLASSIC-TRUE-21-14-20-5-10-3-3-3-3, SG10PCPAR=CLASSIC-CLASSIC-TRUE-21-14-20-5-10-3-3-3-3, SG11PCPAR=CLASSIC-CLASSIC-TRUE-21-14-20-5-10-15-15-15-15, SG12PCPAR=CLASSIC-CLASSIC-TRUE-21-14-20-5-10-15-15-15-15, SG13PCPAR=CLASSIC-CLASSIC-TRUE-21-14-20-5-10-15-15-15-15, SG14PCPAR=CLASSIC-CLASSIC-TRUE-21-14-20-5-10-15-15-15-15, PCMBSTXPRL=15; pcRFLThreshold PWRC:PCRLFTH radioLinkTimeoutBs PWRC:RDLNKTBS A30808-X3247-L230-3-7619 873 Commands Base Station Controller CML:BSC PWRCTD The PWRCTD object represents the parameters used in the power control algorithm. There is one instance for each TD-SCDMA cell controlled by the BSC. GET PWRCTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD PWRCTD GET PWRCTD Applicability: Phase 2. Visibility level 0. Command Description: This command displays the attributes of the Power Control object, modeling the power control algorithmused with a UE/BTSTDand containing the attributes which are generic to any power control algorithm. Validity ranges of the object addresses btsmtdn, "btstdn" and pwrctdn can be found in Appendix A. System Responses: GET PWRCTD NAME=BTSMTD:btsmtdn/BTSTD:btstdn/PWRCTD:pwrctdn [,REQATTL= RDLNKTBSTD, EBSPWRCTD, FASTPCTH, SLOWPCTH, RELATIVEPCR, EDONOPCSSYMDL, EDONOPCSSYMUL, CARRTOIDRACHI, EDONOSCSSYM, CNTUTHTXPUL, CNTUTHTXPDL, CNTLTHTXPUL, PSTEPUL, PSTEPDL, PCLOWTARQDUL, PCLOWTARQPTKUL, PCLOWTARQSHUL, PCUPTARQUDUL, PCUPTARQUPTKUL, PCUPTARQUSHUL, FASTSCTH, SLOWSCTH, PCLOWTHBPTKUL, PCLOWTHBSHUL, PCQUSSDOWN, PCQUSSUP, PCUPTHBPTKUL, PCUPTHBSHUL, AVPRACHINT]; GET ACK: NAME: name RDLNKTBSTD: radioLinkTimeoutBsTD EBSPWRCTD: enableBsPowerControlTD FASTPCTH: fastPCThreshold SLOWPCTH: slowPCThreshold RELATIVEPCR: relativePCRangeDL EDONOPCSSYMDL: enableDoNothingPCSymDL EDONOPCSSYMUL: enableDoNothingPCSymUL CARRTOIDRACHI: carrToIntDesRACHI EDONOSCSSYM: enableDoNothingSCSym CNTUTHTXPUL: cntUpperThresTxPwrUL 874 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get PWRCTD:NAME=BTSMTD:0/BTSTD:0/PWRCTD:0, REQATTL=RDLNKTBSTD&EBSPWRCTD&FASTPCTH&SLOWPCTH& RELATIVEPCR&EDONOPCSSYMDL&EDONOPCSSYMUL& CARRTOIDRACHI&EDONOSCSSYM&CNTUTHTXPUL&CNTUTHTXPDL& CNTLTHTXPUL&PSTEPUL&PSTEPDL&PCLOWTARQDUL& PCLOWTARQPTKUL&PCLOWTARQSHUL&PCUPTARQUDUL& PCUPTARQUPTKUL&PCUPTARQUSHUL&FASTSCTH&SLOWSCTH& PCLOWTHBPTKUL&PCLOWTHBSHUL&PCQUSSDOWN&PCQUSSUP& PCUPTHBPTKUL&PCUPTHBSHUL&AVPRACHINT; CNTUTHTXPDL: cntUpperThresTxPwrDL CNTLTHTXPUL: cntLowerThresTxPwrUL PSTEPUL: powerStepUL PSTEPDL: powerStepDL PCLOWTARQDUL: pcLowTarQualDataUL PCLOWTARQPTKUL: pcLowTarQualPacketUL PCLOWTARQSHUL: PcLowTarQualSpeechUL PCUPTARQUDUL: pcUpTarQualDataUL PCUPTARQUPTKUL: pcUpTarQualPacketUL PCUPTARQUSHUL: pcUpTarQualSpeechUL FASTSCTH: fastSCThreshold SLOWSCTH: slowSCThreshold PCLOWTHBPTKUL: PcLowThrBlerPacketUL PCLOWTHBSHUL: pcLowThrBlerSpeechUL PCQUSSDOWN: pcQualStepSizeDown PCQUSSUP: pcQualStepSizeUp PCUPTHBPTKUL: pcUpThrBlerPacketUL PCUPTHBSHUL: PcUpThrBlerSpeechUL AVPRACHINT: averagePeriodRACHInt GET NACK: NACK CAUSES UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 875 Commands Base Station Controller CML:BSC GET PWRCTD BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD PWRCTD GET PWRCTD BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses btsmtdn, "btstdn" and pwrctdn can be found in Appendix A. System Responses: GET PWRCTD BASICS: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/PWRCTD:pwrctdn; GET ACK: NAME: name RDLNKTBSTD: radioLinkTimeoutBsTD EBSPWRCTD: enableBsPowerControlTD FASTPCTH: fastPCThreshold SLOWPCTH: slowPCThreshold RELATIVEPCR: relativePCRangeDL EDONOPCSSYMDL: enableDoNothingPCSymDL EDONOPCSSYMUL: enableDoNothingPCSymUL CARRTOIDRACHI: carrToIntDesRACHI EDONOSCSSYM: enableDoNothingSCSym CNTUTHTXPUL: cntUpperThresTxPwrUL CNTUTHTXPDL: cntUpperThresTxPwrDL CNTLTHTXPUL: cntLowerThresTxPwrUL PSTEPUL: powerStepUL PSTEPDL: powerStepDL PCLOWTARQDUL: pcLowTarQualDataUL PCLOWTARQPTKUL: pcLowTarQualPacketUL PCLOWTARQSHUL: PcLowTarQualSpeechUL PCUPTARQUDUL: pcUpTarQualDataUL PCUPTARQUPTKUL: pcUpTarQualPacketUL PCUPTARQUSHUL: pcUpTarQualSpeechUL FASTSCTH: fastSCThreshold SLOWSCTH: slowSCThreshold PCLOWTHBPTKUL: PcLowThrBlerPacketUL PCLOWTHBSHUL: pcLowThrBlerSpeechUL PCQUSSDOWN: pcQualStepSizeDown 876 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get PWRCTD BASICS:NAME=BTSMTD:0/BTSTD:0/PWRCTD:0; SET PWRCTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD PWRCTD SET PWRCTD Applicability: Phase 2. Visibility level 2. Command Description: This command sets the attributes of the Power Control object, modeling the power control algorithmused with a UE/BTSTDand containing the attributes which are generic to any power control algorithm. Validity ranges of the object addresses btsmtdn, "btstdn" and pwrctdn can be found in Appendix A. PCQUSSUP: pcQualStepSizeUp PCUPTHBPTKUL: pcUpThrBlerPacketUL PCUPTHBSHUL: PcUpThrBlerSpeechUL AVPRACHINT: averagePeriodRACHInt GET NACK: NACK CAUSES UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SET PWRCTD NAME=BTSMTD:btsmtdn/BTSTD:btstdn/PWRCTD:pwrctdn, RDLNKTBSTD=, EBSPWRCTD=, FASTPCTH=, SLOWPCTH=, RELATIVEPCR=, EDONOPCSSYMDL=, EDONOPCSSYMUL=, CARRTOIDRACHI=, EDONOSCSSYM=, CNTUTHTXPUL=, CNTUTHTXPDL=, CNTLTHTXPUL=, PSTEPUL=, PSTEPDL=, PCLOWTARQDUL=, PCLOWTARQPTKUL=, PCLOWTARQSHUL=, PCUPTARQUDUL=, PCUPTARQUPTKUL=, PCUPTARQUSHUL=, FASTSCTH=, SLOWSCTH=,PCLOWTHBPTKUL=, PCLOWTHBSHUL=, PCQUSSDOWN=, PCQUSSUP=, PCUPTHBPTKUL=,PCUPTHBSHUL=, AVPRACHINT=; A30808-X3247-L230-3-7619 877 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Set PWRCTD:NAME=BTSMTD:0/BTSTD:0/PWRCTD:0,RDLNKTBSTD=4, EBSPWRCTD=TRUE,FASTPCTH=N_03_16,SLOWPCTH=N_12_16, RELATIVEPCR=12,EDONOPCSSYMDL=FALSE, EDONOPCSSYMUL=FALSE,CARRTOIDRACHI=40, EDONOSCSSYM=FALSE,CNTUTHTXPUL=16,CNTUTHTXPDL=16, CNTLTHTXPUL=24,PSTEPUL=N_1_dB,PSTEPDL=N_1_dB, PCLOWTARQDUL=(-0.975),PCLOWTARQPTKUL=(-0.910), PCLOWTARQSHUL=(-0.975),PCUPTARQUDUL=(-0.910), PCUPTARQUPTKUL=(-0.975),PCUPTARQUSHUL=(-0.975),FASTSCTH=N_09_16, SLOWSCTH=N_12_16,PCLOWTHBPTKUL=(-0.975),PCLOWTHBSHUL=(-0.975), PCQUSSDOWN=0.3,PCQUSSUP=1,PCUPTHBPTKUL=(-0.975), PCUPTHBSHUL=(-0.975),AVPRACHINT=1-1-1; SET ACK: Successful SET NACK: NACK CAUSES UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_VAR_OUT_OF_RANGE The attribute RDLNKTBSTD must be a multiple of 4. 878 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PWRD The PWRD object represents the power distributor of the supply voltage for the BSC base module. GET PWRD STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PWRD GET PWRD STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the PWRD object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "pwrdn" can be found in Appendix A. System Responses: Application Guidelines: Only sets with raised bits are shown. Example of Command Execution Get PWRD STAT:NAME=PWRD:0; GET PWRD STAT: NAME=PWRD:pwrdn; GET PWRD STAT ACK: GET PWRD STAT NACK: NACK CAUSES: None. A30808-X3247-L230-3-7619 879 Commands Base Station Controller CML:BSC GETRELATIONSHIP PWRD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCEPWRD GETRELATIONSHIP PWRD Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected HMO (Hardware Managed Object); the relationship information consist of all the FMOs (Functional Managed Object) using the HMO service. This information is included in the RELATED_FUNCTIONAL_OBJECTS attribute (ATTID parameter) and the attribute value depends on the working state of the target HMO. For the PWRD object the MEL is the related FMO. The validity range of the object address "pwrdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship PWRD:NAME=PWRD:0,ATTID=RELATED_FUNCTIONAL_OBJECTS; GETSUBO PWRD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PWRDGETSUBOPWRD GETRELATIONSHIP PWRD: NAME=PWRD:pwrdn, ATTID=; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected HMO the list of related FMOs is displayed (HMO to FMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_ATTRIBUTES The object instance does not provide any relationship attribute. GETSUBO PWRD: NAME=PWRD:pwrdn; 880 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "pwrdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo PWRD:NAME=PWRD:0; GETTEST PWRD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PWRD GETTEST PWRD Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the values of all the attributes belonging to a specified test object; the test object is created by the systemas a result of a request to start a test and it is deleted when the test terminates. The validity range of the object address "pwrdn" can be found in Appendix A. System Responses: GETSUBO PWRD ACK: The output of the command can be composed by one or more pack with a maximumnumber of ten subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GETSUBO PWRD NACK: NACK CAUSES: None. GETTEST PWRD: NAME=PWRD:pwrdn; GETTEST PWRD ACK: GETTEST PWRD:NAME=PWRD:0; name = TEST:<n> A30808-X3247-L230-3-7619 881 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Gettest PWRD:NAME=PWRD:0; LOCK PWRD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PWRD LOCK PWRD Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The command can be rejected due to high criticity of the system state. The validity range of the object address "pwrdn" can be found in Appendix A. mOts = LICDS:0 testState = It can assume one of the following values: not_initialized, idle, initializing, suspended, testing, terminating and disabled. testOutcome = It represents the test result: it can be Inconclusive (meaning-less: that is if the phases already executed were successful) or Fail (if at least one of the executed phases failed). testMonitor phaseId = It is a list of the phases to execute and their status that can be: pass, fail, running or waiting. phaseStatus = phaseId = phaseStatus = .... GETTEST PWRD NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. LOCK PWRD: NAME=PWRD:pwrdn; 882 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock PWRD:NAME=PWRD:0; PERFTEST PWRD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PWRD PERFTEST PWRD Applicability: Phase 2. Visibility level 2. Command Description: This command is used to perform a test on the selected PWRD object; the test consist of the following phases: Power-on Test (start phase), Basic Maintenance Test (WP1), Full Maintenance Test (WP2), End Test (end phase). The validity range of the object address "pwrdn" can be found in Appendix A. System Responses: LOCK PWRD ACK: LOCK PWRD NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. CRITICAL_ALARM_REJECTED The command has been rejected due to high criticity of the system state. PERFTEST PWRD: NAME=PWRD:pwrdn; PERFTEST PWRD ACK: PERFTEST PWRD:NAME=PWRD:0; testObject=TEST:<n> A30808-X3247-L230-3-7619 883 Commands Base Station Controller CML:BSC Application Guidelines: 1. The test can be executed with the object in UNLOCKED administrative state. 2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for test" state. When the test result is: "fail" the object goes in Disabled / Failed operational state; "pass" the object goes in Enabled operational state; "inconclusive" the object returns to the operational state previous to the test or in Enabled operational state. The test results will be displayed at the end of the test phases. Result TEST: name = TEST:<n> testOutcome = This field represents the test result; one of the following values can be displayed: Pass all the test phases are successfully performed. Inconclusive the test is aborted by the system or the test is terminated by the operator. Fail if at least one of the executed phases fail. mOts = It is the identifier of the hardware object under test. testTermination = It specifies how the test is terminated, it can assume the following values: Normal all the test phases are performed. Abort the test is aborted by system. Cancel the test is terminated by operator. executedPhases phaseId = It represents the list of the executed test phases (in case of successful test result, all the test phases will be listed). additionalWords = .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases; they are displayed only for test stopped during it execution. phaseId = .... poprosedRepair Action = A list of most probable fail probable causes is shown (max four messages) PERFTEST PWRD NACK: NACK CAUSES: OTHER_TESTS_RUNNING Other incompatible tests are already running or no more parallel execution of tests are possible. 884 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Perftest PWRD:NAME=PWRD:0; STOPTEST PWRD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PWRD STOPTEST PWRD Applicability: Phase 2. Visibility level 2. Command Description: This command allows to terminate the test previously requested; the test can be in progress or in the waiting list (queued). In the first case the process that execute the diagnostic will be interrupted by executing the end phase; in the second case the test will be removed from the waiting list. The validity range of the object address "pwrdn" can be found in Appendix A. System Responses: STOPTEST PWRD: NAME=PWRD:pwrdn; STOPTEST PWRD ACK: STOPTEST PWRD:NAME=PWRD:0; testObject=TEST:<n> Result TEST: name = TEST:<n> testOutcome = inconclusive mOts = PWRD:0 testTermination = Cancel executedPhases phaseId = It represents the list of the executed test phases; the list is not shown for test in the waiting list (queued). .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases;the list is not shown for test in the waiting list (queued). phaseId = .... STOPTEST PWRD NACK: NACK CAUSES: A30808-X3247-L230-3-7619 885 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Stoptest PWRD:NAME=PWRD:0; UNLOCK PWRD Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE PWRD UNLOCK PWRD Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "pwrdn" can be found in Appendix A. System Responses: Application Guidelines: It is possible to unlock the PWRD card with the status in LOCKED and UNDER TEST. Example of Command Execution Unlock PWRD:NAME=PWRD:0; NO_SUCH_TEST The test is not active. UNABLE_TO_STOP_TEST The test can not be stopped. UNLOCK PWRD: NAME=PWRD:pwrdn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. 886 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller REMINV The REMINV (Remote Inventory) object manages the RCuser Inventory Data File (IDF) request and all its messages flows. ALIGN REMINV Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE REMINV ALIGN REMINV Applicability: Phase 2. Visibility level 2. Command Description: This command performs an upload of the NE IDF from the specified NE instance to the BSC disk to align the central_bsc file. The validity range of the object address "reminvn" can be found in Appendix A. System Responses: Application Guidelines: In order to perform the ALIGN REMINV command, the administrative state of the REMINV object must be LOCKED. ALIGN REMINV: NAME=REMINV:reminvn, NE=; ALIGN ACK: NAME: name ALIGN NACK: NACK CAUSES: ADMINISTRATIVE_STATE_INVALID The command is received during an invalid REMINV state (Init BSC and/or Init NE states). UPLOAD_ALREADY_IN_PROGRESS The command is received while another one is in progress. RESOURCE_NOT_AVAILABLE The command is received when the involved NE is not reachable (BSC-NE link is down or BTSM/BTSMTD is not in unlocked-enable and not in initializing state status). UNSUCCESSFUL_STATUS_BIT_NOT_INITIALIZED The command is occurred when Procedural Status attribute of REMINV object is set at NOT_INITIALIZED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 887 Commands Base Station Controller CML:BSC Example of Command Execution Align REMINV:NAME=REMINV:0,NE=btse((BTSE-1)); Align REMINV:NAME=REMINV:0,NE=btsec((BTSEC-1)); Align REMINV:NAME=REMINV:0,NE=traue((TRAUE-1)); DNLIDFD REMINV Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE REMINV DNLIDFD REMINV Applicability: Phase 2. Visibility level 2. Command Description: This command executes the downloading of the nob-RIU (not on board-Remote Inventory Unit) file (its name must be mandatory BSC_NRIU) fromthe LMT hard-disk to the BSC disk. System Responses: DNLIDFD REMINV: NAME=REMINV:reminvn [,SRCDIR=]; DNLIDFD ACK: The LMT notifies the percentage of the file downloaded in steps of 5%(on the "info line") and the successful completion of the procedure. DNLIDFD NACK: Possible errors, causing the procedure to abort, notified by the LMT are: File Not Found Message Out Of Sequence Aborted By User Time Out Expired Aborted By Network Element File Too Long For Zero Window Size Disk Access Error User Abort Refused Internal SW Error Segment Out Of Sequence Last Segment Expected Disk Write Error Disk Error Crosscopy In Progress Wrong Destination Path 888 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The BSC_NRIU le must be created by means of the IDF editor tool. 2. If a BSC_NRIU le was already present before this command execution, it will be overwritten. 3. This command can be performed with REMINV object both in LOCKED and UNLOCKED administrative state. 4. The directory ../Idf/Dnload, present in the LMT installation, is used for the operation. Example of Command Execution DNLIDFD REMINV:NAME=REMINV:0,SRCDIR="C:\Siemens\ LMT271_10\ Idf\Dnload"; GET REMINV STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE REMINV GET REMINV STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the REMINV object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Control Status (CTS) Procedural Status (PRS) Unknown Status (UNK). The validity range of the object address "reminvn" can be found in Appendix A. Possible errors, causing the procedure to abort, notified by the download task on MPCC and displayed by the LMT are: String Too Long a non-terminated string is present in a message field; Invalid Parameter a message parameter is syntactically incorrect or two message parameters are conflicting; RTE Failure the download task could not obtain an Operating System service; File System Failed the download task could not obtain a File System service; GET REMINV STAT: NAME=REMINV:reminvn; A30808-X3247-L230-3-7619 889 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: The administrative state is handled via LOCK/UNLOCK REMINV commands. The procedural status is handled only at initialization time. The only admitted value is NOT_INITIALIZED, that is also the default initial value and is reset at the end of the initialization phase. Example of Command Execution Get REMINV STAT:NAME=REMINV:0; LOCK REMINV Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE REMINV LOCK REMINV Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set the REMINV object at the administrative state "Locked". The validity range of the object address "reminvn" can be found in Appendix A. System Responses: GET REMINV STAT ACK: USER NAME: COMMAND: SW RELEASE: COMMAND RESULT: GET REMINV STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_SM_TOO_BUSY The message occurs when the Status Handler task is performing the maximum number of commands. LOCK REMINV: NAME=REMINV:reminvn; LOCK REMINV ACK: USER NAME: COMMAND: SW RELEASE: COMMAND RESULT: LOCK REMINV NACK: 890 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state LOCKED will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution: Lock REMINV:NAME=REMINV:0; UNLOCK REMINV Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE REMINV UNLOCK REMINV Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set REMINV object at the administrative state Unlocked. The validity range of the object address "reminvn" can be found in Appendix A. System Responses: Application Guidelines: None. NACK CAUSES: ALREADY_IN_TARGET_STATE The referenced object instance (REMINV:0) is in the administra- tive state LOCKED. UNLOCK REMINV: NAME=REMINV:reminvn; UNLOCK REMINV ACK: USER NAME: COMMAND: SW RELEASE: COMMAND RESULT: UNLOCK REMINV NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The referenced object instance (REMINV:0) is in the adminis- trative state UNLOCKED. A30808-X3247-L230-3-7619 891 Commands Base Station Controller CML:BSC Example of Command Execution: Unlock REMINV:NAME=REMINV:0; UPLCIDF REMINV Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE REMINV UPLCIDF REMINV Applicability: Phase 2. Visibility level 2. Command Description: This command allows the upload of the global IDF file. System Responses: Application Guidelines: 1. The UPLCIDF command can be accepted only if the REMINV object is in LOCKED/ENABLE administrative/operational state. UPLCIDF REMINV: NAME=REMINV:reminvn [,DESTDIR=] [,FILE=] ,OVERWRITE=; UPLCIDF ACK: Uploading File: REMIN6/SBS IDT.CPX From Directory: To: BSC.ZTD On Directory:..\Idf\Upload USER NAME: COMMAND: SW RELEASE: COMMAND RESULT: UPLCIDF NACK: NACK CAUSES: ADMINISTRATIVE_STATE_INVALID The command is occurred when REMINV object is in INIT BSC and or INIT NE state or in UNLOCKED state. UNSUCCESSFUL_STATUS_BIT_NOT_INITIALIZED The command is occurred when Procedural Status attribute of REMINV object is set at NOT_INITIALIZED. UPLOAD_ALREADY_IN_PROGRESS The command is occurred when another UPLOAD procedure is in progress. 892 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 2. When the Upload is in progress, no other operator command on REMINV object can be accepted. 3. The global IDF is built compressing together the local BSC IDF and the IDFs of all the NEs that are created. These IDFs are made using the data present on BSC disk system at the time the UPLCIDF command is in progress.The le name must have .zdt extension. 4. The directory ../Idf/Upload, present in the LMT installation, is used to load the bsc.zdt le. 5. If remote inventory data from a BTSE, BTSEC or TRAU entity are aligned with the ALIGN REMINV command, it is necessary to unlock and lock again the remote inventory to have the data available for upload and the display. Example of Command Execution UPLCIDF REMINV:NAME=REMINV:0,DESTDIR="c:\Siemens\Idf\Upload", FILE="bsc_central.zdt",OVERWRITE=YES; A30808-X3247-L230-3-7619 893 Commands Base Station Controller CML:BSC UPLLIDF REMINV Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE REMINV UPLLIDF REMINV Applicability: Phase 2. Visibility level 2. Command Description: This command allows the upload of the local IDF file. System Responses: Application Guidelines: 1. The UPLLIDF command can be executed only if the REMINV object is in LOCKED/ENABLE administrative/operational state. 2. When the Upload is in progress, no other operator command on REMINV object can be accepted. 3. The le name (FILE parameter) must have .idt extension. 4. The directory ../Idf/Upload, present in the LMT installation, is used to load the bsc.idt le. UPLLIDFREMINV: NAME=REMINV:reminvn [,DESTDIR=] [,FILE=] ,OVERWRITE=; UPLLIDF ACK: Uploading File: REMIN6/BSC IDT From Directory: To: BSC.IDT On Directory:..\Idf\Upload USER NAME: COMMAND: SW RELEASE: COMMAND RESULT: UPLLIDF NACK: NACK CAUSES: ADMINISTRATIVE_STATE_INVALID The command is occurred when REMINV object is in INIT BSC and or INIT NE state or in UNLOCKED state. UNSUCCESSFUL_STATUS_BIT_NOT_INITIALIZED The command is occurred when Procedural Status attribute of REMINV object is set at NOT_INITIALIZED. UPLOAD_ALREADY_IN_PROGRESS The command is occurred when another UPLOAD procedure is in progress. 894 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution UPLLIDF REMINV:NAME=REMINV:0,DESTDIR="c:\Siemens\Idf\Upload", FILE="bsc_local.idt",OVERWRITE=YES; A30808-X3247-L230-3-7619 895 Commands Base Station Controller CML:BSC RFLOOP The RFLOOP object allows the operator to test the complete RF signal path of a BTSE including the cabling and connectors and will thus significantly enhance the overall test coverage. CREATE RFLOOP Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS RFLOOP CREATE RFLOOP Applicability: Phase 2. Visibility level 2. Command Description: This command allows to create the RFLOOP object. Validity ranges of the object addresses btsmn, btsn and "rfloopn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Create RFLOOP:NAME=BTSM:0/BTS:0/RFLOOP:0,START=1-1-2001, STOP=2-2-2002,ALTH=30,MINCCNT=50,MECNT=200,RXLV=10,AUTOREP=TRUE, BANDOFHYS=25; CREATE RFLOOP: NAME=BTSM:btsmn/BTS:btsn/RFLOOP:rfloopn [,START=] [,STOP=] [,ALTH=] [,MINCCNT=] [,MECNT=] [,RXLV=] [,AUTOREP=] [,BANDOFHYS=]; CREATE ACK: SUCCESSFUL CREATE NACK: NACK CAUSES: . OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The superordinate object instances must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. 896 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DELETE RFLOOP Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS RFLOOP DELETE RFLOOP Applicability: Phase 2. Visibility level 2. Command Description: The command deletes a RFLOOP instance which has been previously created. Validity ranges of the object addresses btsmn, btsn and "rfloopn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete RFLOOP:NAME=BTSM:0/BTS:0/RFLOOP:0; GET RFLOOP Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS RFLOOP GET RFLOOP DELETE RFLOOP NAME=BTSM:btsmn/BTS:btsn/RFLOOP:rfloopn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a RFLOOP, the relative object instance must be in LOCKED state. GET RFLOOP NAME=BTSM:btsmn/BTS:btsn/RFLOOP:rfloopn [,REQATTL=START, STOP, ALTH, MINCCNT, MECNT, RXLV, AUTOREP,BANDOFHYS]; A30808-X3247-L230-3-7619 897 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the values of the parameters selected by the operators by means of REQATTL field. Validity ranges of the object addresses btsmn, btsn and "rfloopn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get RFLOOP:NAME=BTSM:0/BTS:0/RFLOOP:0, REQATTL=START&STOP&ALTH& MINCCNT&MECNT&RXLV&AUTOREP&BANDOFHYS; GET RFLOOP BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS RFLOOP GET RFLOOP BASICS Applicability: Phase 2. Visibility level 1. GET ACK: NAME: name START: startDate STOP: stopDate ALTH: alarmThreshold MINCCNT: minCallCount MECNT: measCount RXLV: rxLevel AUTOREP: autoReport BANDOFHYS: bandWidthOfHysteresis GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET RFLOOP BASICS: NAME=BTSM:btsmn/BTS:btsn/RFLOOP:rfloopn; 898 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses btsmn, btsn and "rfloopn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get RFLOOP BASICS:NAME=BTSM:0/BTS:0/RFLOOP:0; GET RFLOOP STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS RFLOOP GET RFLOOP STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the RFLOOP object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) GET ACK: NAME: name START: startDate STOP: stopDate ALTH: alarmThreshold MINCCNT: minCallCount MECNT: measCount RXLV: rxLevel AUTOREP: autoReport BANDOFHYS: bandWidthOfHysteresis GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET RFLOOP STAT: NAME=BTSM:btsmn/BTS:btsn/RFLOOP:rfloopn; A30808-X3247-L230-3-7619 899 Commands Base Station Controller CML:BSC Control Status (CTS) Procedural Status (PRS) Unknown Status (UNK). Validity ranges of the object addresses btsmn, btsn and "rfloopn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get RFLOOP STAT:NAME=BTSM:0/BTS:0/RFLOOP:0; LOCK RFLOOP Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS RFLOOP LOCK RFLOOP Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". Validity ranges of the object addresses btsmn, btsn and "rfloopn" can be found in Appendix A. System Responses: GET RFLOOP STAT ACK: GET RFLOOP STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK RFLOOP: NAME=BTSM:btsmn/BTS:btsn/RFLOOP:rfloopn; LOCK RFLOOP ACK: LOCK RFLOOP NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 900 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock RFLOOP:NAME=BTSM:0/BTS:0/RFLOOP:0; SET RFLOOP Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS RFLOOP SET RFLOOP Applicability: Phase 2. Visibility level 2. Command Description: This command allows the user to change the setting related to a RFLOOP object previously created. Validity ranges of the object addresses btsmn, btsn and "rfloopn" can be found in Appendix A. System Responses: Application Guidelines: None. SET RFLOOP: NAME=BTSM:btsmn/BTS:btsn/RFLOOP:rfloopn [,START=] [,STOP=] [,ALTH=] [,MINCCNT=] [,MECNT=] [,RXLV=] [,AUTOREP=] [,BANDOFHYS=]; SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The superordinate object instances must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. A30808-X3247-L230-3-7619 901 Commands Base Station Controller CML:BSC Example of Command Execution Set RFLOOP:NAME=BTSM:0/BTS:0/RFLOOP:0,START=1-1-2001,STOP=1-2-2001, ALTH=25; UNLOCK RFLOOP Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS RFLOOP UNLOCK RFLOOP Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state "Unlocked". Validity ranges of the object addresses btsmn, btsn and "rfloopn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock RFLOOP:NAME=BTSM:0/BTS:0/RFLOOP:0; UPLOADREQ RFLOOP Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS RFLOOP UPLOADREQ RFLOOP UNLOCK RFLOOP: NAME=BTSM:btsmn/BTS:btsn/RFLOOP:rfloopn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UPLOADREQ RFLOOP: NAME=BTSM:btsmn/BTS:btsn/RFLOOP:rfloopn ,DESTDIR= ,OVERWRITE= ; 902 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 2. Command Description: This command allows the user to upload the files fromthe BSC disk to the LMT disk; the destination directory, the file name and the file overwriting (or not) must be defined by the user. Validity ranges of the object addresses btsmn, btsn and scan" can be found in Appendix A. System Responses: Application Guidelines: 1. If the scannerlogle is uploaded with OVERWRITE parameter set at NOand the le already exists on the LMT disk, the LMT renames the existing one to oldfilename_DayMonthYearHourMinute.Thesameextention and stores the uploaded one to the disk. 2. If the user aborts the upload command or the link (between LMT and BSC) falls down, then it is no more possible to upload the same le: a new measure le will be created until new log les will be produced inside BSC. Example of Command Execution Uploadreq RFLOOP:NAME=BTSM:0/BTS:0/RFLOOP:0,DESTDIR="C:\Siemens", FILE="File_name",OVERWRITE=YES; UPLOADREQ ACK: UPLOADREQ NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before launching this command, the relative object instance must be in LOCKED state. According to the configured stopDate field value, measurement data collection is finished (i.e. the stopDate has been reached): the upload cannot be executed since measures are not present in the BTS equip- ment. A30808-X3247-L230-3-7619 903 Commands Base Station Controller CML:BSC RSUDB The RSUDB (Replaceable Software Unit DataBase) represents an instance of a managed object class identifying database files. All related commands (except CREATE RSUDB) consist of two fields but only one can be used (NAME or USER LABEL DB). CREATE RSUDB Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUDB CREATE RSUDB Applicability: Phase 2. Visibility level 2. Command Description: This command allows to execute the download of a database file on BSC disk. System Responses: CREATE RSUDB: ULAB=, SRCPATH=; CREATE ACK: CREATE NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. No download in progress with this transfer identifier. NO_TASKS_AVAILABLE No free servers are available to perform the command. ABORT_BY_SYSTEM_NCK An internal subsystem abort has occurred. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. INVALID_PARAMETER_NCK The file name is too long (a maximum of 14 characters is admitted). The object address is incorrect. The userLabel attribute (ULAB) already used for another RSUDB. The file related to the new object is already used for another RSU object. The object already exists but with different attributes. NO_INSTANCE_FREE The maximum number of ESUDB instances is already created. 904 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The command is performed if the Related Database le is present on LMT hard-disk. 2. The creation of a RSUDB instance implies the automatic creation of the related BSCESUDB. Example of Command Execution Create RSUDB:ULAB=user_label,SRCPATH=D:\BR61\BSC\hb010140\Dbfile.dba; DELETE RSUDB Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUDB DELETE RSUDB Applicability: Phase 2. Visibility level 2. Command Description: This command performs a deletion of a RSUDB object. The validity range of the object address rsudbn can be found in Appendix A. System Responses: PROCESSING_ERROR_NCK The object address is not available. OBJECT_NOT_FOUND The referenced object instance does not exist. DUPLICATED_OBJECT The involved object instance is already present. DUPLICATED_OBJECT_RSU_DISABLED The involved object instance already exists but a recovery download can be performed. DELETE RSUDB: IDRSUDB; DELETE ACK: DELETE NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. A30808-X3247-L230-3-7619 905 Commands Base Station Controller CML:BSC Application Guidelines: 1. If RSUDB instance is related to a BSCESUDB pointed by backupESU BSCOSUDB attribute or runningESU BSCOSUDB attribute or newESU BSCOSUDB attribute or fallbackESU BSCOSUDB attribute, then the deletion is not allowed. 2. The deletion of RSUDB object implies the automatic deletion of the related BSCESUDB object. Example of Command Execution Delete RSUDB:NAME=RSUDB:0; Delete RSUDB:IDRSUDB="userLabel"; GET RSUDB Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUDB GET RSUDB Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of the different attributes of RSUDB objects. The validity range of the object address rsudbn can be found in Appendix A. System Responses: OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK An internal subsystem abort has occurred. ESU_OBJ_POINTED_BY_OSU_ATTR The related ESUDB object can not be deleted (it is pointed by one of the OSUDB attributes). GET RSUDB IDRSUDB= [,REQATTL=ULAB, RELF, DBVER]; GET ACK: ULAB: userLabel RELF: relatedFiles DBVER: dataBaseVersion GET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. 906 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: If a GET RSUDB command is issued with a wrong USER LABEL DB in the IDRSUDB attribute, the field Object Instance of the LMT Message Browser might include a free RSUDB instance, rather than being n.a.. Example of Command Execution Get RSUDB:NAME=RSUDB:0,REQATTL=ULAB&RELF&DBVER; Get RSUDB:IDRSUDB="16_08",REQATTL=ULAB&RELF&DBVER; GET RSUDB BASICS Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUDB GET RSUDB BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve all the parameters of RSUDB object. The validity range of the object address rsudbn can be found in Appendix A. System Responses: NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK An internal subsystem abort has occurred. NO_INSTANCE_FREE If the command is a GET RSUDB object instance. GET RSUDB BASICS: IDRSUDB=; GET RSUDB BASICS ACK: ULAB: userLabel RELF: relatedFiles DBVER: dataBaseVersion GET RSUDB BASICS NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. A30808-X3247-L230-3-7619 907 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get RSUDB BASICS:NAME=RSUDB:0; Get RSUDB BASICS:IDRSUDB="userLabel"; GET RSUDB STAT Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUDB GET RSUDB STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the RSUDB object: Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Unknown Status (UNK). The validity range of the object address rsudbn can be found in Appendix A. System Responses: NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK An internal system abort has occurred. NO_INSTANCE_FREE If the command is a GET RSUDB object instance. GET RSUDB STAT: IDRSUDB=; GET RSUDB STAT ACK: Refer to command description. GET RSUDB STAT NACK: 908 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get RSUDB STAT:NAME=RSUDB:0; Get RSUDB STAT:IDRSUDB="userLabel"; SET RSUDB Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUDB SET RSUDB Applicability: Phase 2. Visibility level 2. Command Description: This command performs a change value of userLabel RSUDB attribute (ULAB). The validity range of the object address rsudbn can be found in Appendix A. System Responses: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_SM_TOO_BUSY The message occurs when the Status Handler task is performing the maximum number of commands. SET RSUDB: IDRSUDB=, ULAB=; SET ACK: SET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. INVALID_PARAMETER_NCK The userLabel attribute (ULAB) already used for another RSUDB. OBJECT_NOT_FOUND A30808-X3247-L230-3-7619 909 Commands Base Station Controller CML:BSC Application Guidelines: This command is not performed if specific userLabel (ULAB) value is already present; in this case the command is rejected. Example of Command Execution Set RSUDB:NAME=RSUDB:0,ULAB="newUserLabel"; Set RSUDB:IDRSUDB="oldUserLabel",ULAB="newUserLabel"; UPLDFILE RSUDB Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUDB UPLDFILE RSUDB Applicability: Phase 2. Visibility level 2. Command Description: This command performs an upload of the data base object file. The validity range of the object address rsudbn can be found in Appendix A. System Responses: The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK An internal subsystem abort has occurred. UPLDFILE RSUDB: IDRSUDB=, DESTDIR=, OWR=; UPLDFILE ACK: UPLDFILE NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. No upload in progress with this transfer identifier. NO_TASKS_AVAILABLE No free servers are available to perform the command. ABORT_BY_SYSTEM_NCK An internal system abort is occurred. OBJECT_NOT_FOUND The referenced object instance does not exist. INVALID_PARAMETER_NCK The file type is not DATABASE. OBJECT_ALREADY_IN_USE 910 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: To performthis command RSUDB object must be present and no other operation on the Database must be in progress. Example of Command Execution Upldle RSUDB:NAME=RSUDB:0,DESTDIR="D:\",OWR=YES; Upldle RSUDB:IDRSUDB="userLabel",DESTDIR="D:\",OWR=YES; The command clashes with another one already in progress. FILE_NOT_FOUND The file to be transferred is not present. A30808-X3247-L230-3-7619 911 Commands Base Station Controller CML:BSC RSUEXE The RSUEXE (Replaceable Software Unit Executable) represents an instance of a managed object class identifying executable and VAM files. All related commands (except CREATE RSUEXE) consist of two fields but only one can be used (NAME or USER LABEL SWLH). CREATE RSUEXE Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE CREATE RSUEXE Applicability: Phase 2. Visibility level 2. Command Description: This command allows to performthe download of a single executable or VAMfile on the BSC disk. System Responses: CREATE RSUEXE: SRCPATH=, ULABSWLH=, HEADER=; CREATE ACK: CREATE NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. No download in progress with this transfer identifier. NO_TASKS_AVAILABLE No free servers are available to perform the command. ABORT_BY_SYSTEM_NCK An internal system abort is occurred. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. INVALID_PARAMETER_NCK The file name is too long (a maximum of 14 characters is admitted). The object address is incorrect. The RSUEXE Network Element attribute is different from the correspondent RSUSWLH. A creation of two RSUEXE Network Elements with the same software version and processor type and belonging to the same RSUSWLHhas occurred. 912 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: The RSUEXE object instance can be created only if the related RSUSWLH object instance has been already created and if the related executable file is present on the LMT hard disk. Example of Command Execution Create RSUEXE:SRCPATH=D:\BR61\BSC\hb010140\m10140.abs, ULABSWLH=Load13, HEADER=Hb010022.swl; DELETE RSUEXE Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE DELETE RSUEXE Applicability: Phase 2. Visibility level 2. Command Description: This command performs a deletion of the RSUEXE object. Validity ranges of the object addresses rsuswlhn and rsuexen can be found in Appendix A. A creation of two BSC RSUEXEs with the same processor type and belonging to the same RSUSWLH has occurred. The object already exists but with different attributes. A RSUEXE with the same file name and belonging to the same RSUSWLH is already created. The file related to the new object is already used for another RSU object. NO_INSTANCE_FREE The maximum number of RSUEXE instances is already created. SW_LOAD_HEADER_NOT_FOUND_NCK The RSUSWLH owning this RSUEXE is not existent. PROCESSING_ERROR_NCK The creation of the new object instance has failed. OBJECT_NOT_FOUND The referenced object instance does not exist. DUPLICATED_OBJECT The involved object instance is already present. DUPLICATED_OBJECT_RSU_DISABLED The involved object instance already exists but a recovery download can be performed. DELETE RSUEXE: IDRSUEXE=; A30808-X3247-L230-3-7619 913 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: 1. The delete RSUEXE operation is not allowed if the RSUEXE instance is related to a BSCESUSW or a NEYESUSW instance pointed by: backupESU NEYESUSW or BSCESUSW attribute; newESU NEYESUSW or BSCESUSW attribute; fallbackESU NEYESUSW or BSCESUSW attribute; runningESU NEYESUSW or BSCESUSW attribute. 2. The deletion of RSUEXE object implies the deletion of all the RSUPCH objects contained into it. Example of Command Execution Delete RSUEXE:NAME=RSUSWLH:17/RSUEXE:1; Delete RSUEXE:IDRSUEXE="userLabel"-PPXL-"Y10700.ABS"; GET RSUEXE Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE GET RSUEXE Applicability: Phase 2. Visibility level 0. DELETE ACK: DELETE NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK An internal subsystem abort has occurred. ESU_OBJ_POINTED_BY_OSU_ATTR The deletion of a RSUEXE belonging to an ESUSW pointed by an OSUSW attribute is allowed only if the RSUEXE is DISABLED-FAILED. GET RSUEXE IDRSUEXE= [,REQATTL=VER, PROCTYP, RELF]; 914 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command is used to retrieve different attributes of the RSUEXE object. Validity ranges of the object addresses rsuswlhn and rsuexen can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution GET RSUEXE: NAME=RSUSWLH:1/RSUEXE:0,REQATTL=VER&PROCTYP&RELF; GET RSUEXE: IDRSUEXE="userLabel"-MPCC-"M10900.ABS", REQATTL=VER&PROCTYP&RELF; GET RSUEXE BASICS Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE GET RSUEXE BASICS GET ACK: VER: version PROCTYP: processorType RELF: relatedFiles GET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK An internal subsystem abort has occurred. SW_LOAD_HEADER_NOT_FOUND_NCK If the command is a GET RSUEXE object instance. NO_INSTANCE_FREE If the command is a GET RSUEXE object instance. GET RSUEXE BASICS: IDRSUEXE=; A30808-X3247-L230-3-7619 915 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve all the attributes of the RSUEXE object. Validity ranges of the object addresses rsuswlhn and rsuexen can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get RSUEXE BASICS:NAME=RSUSWLH:9/RSUEXE:0; Get RSUEXE BASICS:IDRSUEXE="userLabel"-MPCC-"M10800.ABS"; GET RSUEXE STAT Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUEXE GET RSUEXE STAT GET ACK: VER: version PROCTYP: processorType RELF: relatedFiles GET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK An internal system abort is occurred. NO_INSTANCE_FREE SW_LOAD_HEADER_NOT_FOUND_NCK GET RSUEXE STAT: ,IDRSUEXE=; 916 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the RSUEXE object: Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Unknown Status (UNK). Validity ranges of the object addresses rsuswlhn and rsuexen can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get RSUEXE STAT:NAME=RSUSWLH:9/RSUEXE:0; Get RSUEXE STAT:IDRSUEXE="userLabel"-MPCC-"M10800.ABS"; GET RSUEXE STAT ACK: GET RSUEXE STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_SM_TOO_BUSY The message occurs when the Status Handler task is performing the maximum number of commands. A30808-X3247-L230-3-7619 917 Commands Base Station Controller CML:BSC RSUPCH The RSUPCH (Replaceable Software Unit Patch) represents an instance of a managed object class identifying a software patch related to e.g. MPCC, TDPC or PPCU processor. The RSUPCH object also handles the unpatch (if any) associated to a software patch. The unpatch is a particular patch that allows to remove a patch without any system downtime. Each unpatch is associated to a specific patch. All related commands (except CREATE RSUPCH) consist of two fields but only one can be used (NAME or USER LABEL SWLH). CREATE RSUPCH Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE RSUPCH CREATE RSUPCH Applicability: Phase 2. Visibility level 2. Command Description: This command allows to perform the download of a single patch file (and of the related unpatch file, if any) on the BSC disk. System Responses: CREATE RSUPCH: ULAB= ,PROCTYP= ,PERM= [,PRIOSLOTN=] ,SRCPATH= ,ULABSWLH=; CREATE ACK: CREATE NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. No download in progress with this transfer identifier. Delete command not allowed for a permanent RSUPCH. NO_TASKS_AVAILABLE No free servers are available to perform the command. ABORT_BY_SYSTEM_NCK An internal subsystem abort has occurred. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. INVALID_PARAMETER_NCK The file name is too long (a maximum of 14 characters is admitted). The object address is incorrect. 918 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Wrong processor type specified. Wrong initial letter for the patch file name. File name already used for another RSUPCH. Only the file name extensions .PCH and .BAK are allowed for a RSUPCH object. The creation of a RSUPCH unpatch object without the related RSUPCH patch object is rejected. File name already used for another RSUPCH. Processor type attribute of the RSUPCH is different from RSUEXE one. The RSUPCH has same UserLabel attribute of related RSUSWLH. A creation of two RSUPCHs with the same UserLabel and belonging to the same RSUEXE is occurred. The file related to the new object is already used for another RSU object. The object already exists but with different attributes. The creation of RSUPCH unpatch object with slot attribute different from NULL VALUE is rejected. The creation of a RSUPCH object with a slot number equal to another one already present is rejected. A RSUPCH object with permanent attribute TRUE and slot number NULL is not admitted. The slot number is equal to another already present. Slot value out of range. Max slot number has been assigned to another patch: you must specify a slot for the new patch or modify the max slot for the patch present. NO_INSTANCE_FREE The maximum number of RSUPCH instances is already created. SW_LOAD_HEADER_NOT_FOUND_NCK The RSUEXE owning this RSUPCH is not existent. PROCESSING_ERROR_NCK The creation of the new object instance is failed. OBJECT_NOT_FOUND The referenced object instance does not exist. DUPLICATED_OBJECT The involved object instance is already present. DUPLICATED_OBJECT_RSU_DISABLED The involved object instance already exists but a recovery download can be performed. CREATE_UNPATCH_NOT_ALLOWED_WITHOUT_RELATED_PATCH In case the file name extension is BAK the related patch object must be already present (created). The specific unpatch file has to be available on LMT disk and it must have the same file name of the related patch with the extension PCH. PATCH_SW_VERSION_NOT_COMPATIBLE The patch (unpatch) SW version, contained into the related file, must be compatible with the one of the RSUEXE containing it. If this is not verified the created patch (unpatch) is put in DISABLED-FAILED state. A30808-X3247-L230-3-7619 919 Commands Base Station Controller CML:BSC Application Guidelines: 1. The RSUPCH object instance can be created only if the related RSUEXE object instance has been already created and if the related patch le is present on the LMT hard disk. 2. The specic patch le name extension must be PCH. 3. The specic unpatch le name extension must be BAK. 4. In case the le name extension is BAK the PERM attribute must be set at FALSE. 5. The unpatch cannot have the same userLabel of the SW load that contains it. 6. The RSUPCH unpatch object can be created only if the related RSUPCH patch object instance has been already created. Example of Command Execution Create RSUPCH:ULAB="M1140000",PROCTYP=MPCC,PERM=TRUE, PRIOSLOTN=10, SRCPATH="D:\BR61\BSC\hb010043\M1140000.PCH",ULAB- SWLH="HB010043.SWL"; DELETE RSUPCH Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE RSUPCH DELETE RSUPCH Applicability: Phase 2. Visibility level 2. Command Description: This command deletes the RSUPCH object and also its related (if any) unpatch. Validity ranges of the object addresses rsuswlhn, rsuexen and rsupchn can be found in Appendix A. System Responses: DELETE RSUPCH: IDRSUPCH=; DELETE ACK: DELETE NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. The deletion of a RSUPCH with the permanent attribute TRUE or belonging to a ESUSWpointed by an OSUSWattribute is allowed only if the RSUPCH is DISABLED-FAILED. Delete command not allowed for a RSUPCH whose status is not OFF DUTY. NO_TASKS_AVAILABLE 920 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. If RSUPCH instance has AVS attribute different from OFF_DUTY or it has PERM attribute equal to TRUE and is related to a BSCESUSWor a NEYESUSWinstance pointed by backupESU, runningESU, newESU or fallbackESU attribute of BSCO- SUSW or a NEYESUSW, the command is not allowed. 2. The patch deletion implies an automatic deletion of the related (if any) unpatch. 3. In case the command is applied to unpatch object, the specic unpatch object has to be present. 4. If the RSUPCH object to delete has got .PCH extension, the related RSUPCH unpatch .BAK is deleted too (if any). Example of Command Execution Delete RSUPCH:NAME=RSUSWLH:0/RSUEXE:0/RSUPCH:0; Delete RSUPCH:IDRSUPCH="userLabel SWLH"-"userLabel"-MPCC; GET RSUPCH Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE RSUPCH GET RSUPCH Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve values of the different attributes of the RSUPCH object. Validity ranges of the object addresses rsuswlhn, rsuexen and rsupchn can be found in Appendix A. System Responses: No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK An internal susystem abort has occurred. GET RSUPCH IDRSUPCH= [,REQATTL=ULAB, PROCTYP, PERM, RELF]; GET ACK: ULAB: userLabel PROCTYP: processorType PERM: permanent A30808-X3247-L230-3-7619 921 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get RSUPCH: NAME=RSUSWLH:1/RSUEXE:0/RSUPCH:0, REQATTL=ULAB&PROCTYP&PERM&RELF; Get RSUPCH:IDRSUPCH="userLabel SWLH"-"userLabel"-MPCC; GET RSUPCH BASICS Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE RSUPCH GET RSUPCH BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve all the parameters of the RSUPCH object. Validity ranges of the object addresses rsuswlhn, rsuexen and rsupchn can be found in Appendix A. RELF: relatedFiles GET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK An internal subsystem abort has occurred. INVALID_PARAMETER_NCK If the command is a GET RSUPCH object instance. SW_LOAD_HEADER_NOT_FOUND_NCK If the command is a GET RSUPCH object instance. NO_INSTANCE_FREE If the command is a GET RSUPCH object instance. GET RSUPCH IDRSUPCH=; 922 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Get RSUPCH BASICS:NAME=RSUSWLH:9/RSUEXE:1/RSUPCH:9; Get RSUPCH BASICS: IDRSUPCH="userLabelSWLH"-"userLabelPCH"-TDPC; GET RSUPCH STAT Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE RSUPCH GET RSUPCH STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the RSUPCH object: Operational State (OST) Alarm Status (ALS) Availability Status (AVS) GET ACK: ULAB: userLabel PROCTYP: processorType PERM: permanent RELF: relatedFiles GET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK An internal system abort has occurred. GET RSUPCH STAT: ,IDRSUPCH=; A30808-X3247-L230-3-7619 923 Commands Base Station Controller CML:BSC Control Status (CTS) Procedural Status (PRS) Unknown Status (UNK). Validity ranges of the object addresses rsuswlhn, rsuexen and rsupchn can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get RSUPCH STAT:NAME=RSUSWLH:9/RSUEXE:1/RSUPCH:9; Get RSUPCH STAT:IDRSUPCH="userLabelSWLH"-"userLabelPCH"-TDPC; LOADPATCH RSUPCH Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE RSUPCH LOADPATCH RSUPCH Applicability: Phase 2. Visibility level 2. Command Description: This command allows to the operator to load the patch. A command acknowledge is request by the system by means of a window CLI message (LOADPATCH RSUPCH: EXECUTE COMMAND?); if OK is selected, the command will be executed. Validity ranges of the object addresses rsuswlhn, rsuexen and rsupchn can be found in Appendix A. System Responses: GET RSUPCH STAT ACK: GET RSUPCH STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_SM_TOO_BUSY The message occurs when the Status Handler task is performing the maximum number of commands. LOADPATCH RSUPCH: IDRSUPCH=; LOADPATCH ACK: SUCCESSFUL LOADPATCH NACK: 924 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. To perform this command OperationalState attribute of RSUPCH object must be ENABLED and the Load Usage state attribute of BSCOSUSWobject must be IDLE. 2. The command is allowed only for a RSUPCH patch object with .PCH extension. Example of Command Execution Loadpatch RSUPCH:NAME=RSUSWLH:0/RSUEXE:0/RSUPCH:0; Loadpatch RSUPCH:IDRSUPCH="uselLabelSWLH"-"userLabelPCH"-MPCC; SET RSUPCH Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE RSUPCH SET RSUPCH Applicability: Phase 2. Visibility level 2. Command Description: This command performs enabling or disabling of the RSUPCHobject, that is, referenced patch can be set to permanent or not (PERMparameter). This command performs also a slot number useful to give an order during a bring up operation to the patches to be loaded. NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. The RSUPCH does not belong to the running BSCESUSW. The phase of the BSCOSUSW is different from IDLE. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_NOT_FOUND The referenced object instance does not exist. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. INCONSISTENT_STATE_NCK DISABLED RSUPCH can not be loaded. ABORT_BY_SYSTEM_NCK An internal system abort is occurred. LOAD_PATCH_NOT_ALLOWED_FOR_AN_UNPATCH_OBJ The command is applicable only to a RSUPCH object with file name extension PCH. SET RSUPCH [IDRSUPCH=] [,PERM=] [,PRIOSLOTN=]; A30808-X3247-L230-3-7619 925 Commands Base Station Controller CML:BSC Validity ranges of the object addresses rsuswlhn, rsuexen and rsupchn can be found in Appendix A. System Responses: Application Guidelines: 1. To perform an enabling patch (permanent), OperationalState attribute of the RSUPCH object must be ENABLED and the Load Usage state attribute of BSCOSUSW object must be IDLE. 2. To perform a disabling patch (not permanent), the specic RSUPCH object has to be available on BSC disk and the Load Usage state attribute of BSCOSUSWmust be IDLE. 3. The command is allowed only for a RSUPCH patch object with .PCH extension. 4. It is not allowed to set a RSUPCH patch permanent TRUE and slot NULL. Example of Command Execution Set RSUPCH:NAME=RSUSWLH:0/RSUEXE:0/RSUPCH:0,PERM=TRUE, PRIOSLOTN=10; Set RSUPCH: IDRSUPCH="userLabelSWLH"-"userLabelPCH"-SWLH,PERM=TRUE, PRIOSLOTN=10; SET ACK: SET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. BSCOSUSW phase different from IDLE. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. OBJECT_NOT_FOUND The referenced object instance does not exist. INCONSISTENT_STATE_NCK The PERM attribute of a DISABLE RSUPCH can not be set at TRUE value. INVALID_PARAMETER_NCK A RSUPCH object with permanent attribute TRUE and slot number NULL is not admitted. The slot number is equal to another one already present. Slot value out of range. ABORT_BY_SYSTEM_NCK An internal system abort is occurred. SET_NOT_ALLOWED_FOR_AN_UNPATCH The RSUPCH object contained in the command has to be linked to a file with extension PCH. 926 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller UNLOADPCH RSUPCH Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE RSUPCH UNLOADPCH RSUPCH Applicability: Phase 2. Visibility level 2. Command Description: This command allows to the operator to unload the patch. A command acknowledge is request by the system by means of a window CLI message (UNLOADPATCH RSUPCH: EXECUTE COMMAND?); if it is selected OK, the command will be executed. Validity ranges of the object addresses rsuswlhn, rsuexen and rsupchn can be found in Appendix A. System Responses: UNLOADPCH RSUPCH: IDRSUPCH=; UNLOADPCH ACK: SUCCESSFUL UNLOADPCH NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. The RSUPCH does not belong to the running BSCESUSW. The BSCOSUSW phase is different from IDLE. NO_TASK_AVAILABLE No free servers to perform the command. OBJECT_NOT_FOUND The object involved in this command does not exist. No unload patch command is allowed. The related RSUPCH object with file name extension BAK doesnt exist. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. INCONSISTENT_STATE_NCK A DISABLED RSUPCH can not be loaded. Unload patch command not allowed for a RSUPCHwhose avail. status is not NONE. INVALID_PARAMETER_NCK Unload patch command not allowed for a permanent RSUPCH. ABORT_BY_SYSTEM_NCK A30808-X3247-L230-3-7619 927 Commands Base Station Controller CML:BSC Application Guidelines: 1. The PERM attribute must be set at FALSE. 2. To perform this command the RSUPCH availability status must be NONE and the OperationalState attribute of the related unpatch must be ENABLED. 3. When the unload patch succeeds the patch availability status changes from NONE to OFF DUTY. 4. The command is allowed only for a RSUPCH patch object with .PCH extension. Example of Command Execution Unloadpch RSUPCH:NAME=RSUSWLH:0/RSUEXE:0/RSUPCH:0; Unloadpch RSUPCH:IDRSUPCH="uselLabelSWLH"-"userLabelPCH"-MPCC; This command is rejected due to an internal subsystem abort. UNLOAD_PATCH_NOT_ALLOWED_FOR_AN_UNPATCH_OBJ The command is applicable only to a RSUPCH object with file name extension PCH. 928 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller RSUSWLH The RSUSWLH (Replaceable Software Unit SW Load Headers) object class identifies the software load header files. All related commands (except CREATE RSUSWLH) consist of two fields but only one can be used (NAME or USER LABEL SWLH). CREATE RSUSWLH Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH CREATE RSUSWLH Applicability: Phase 2. Visibility level 2. Command Description: This command allows to execute the download of a software load header file on a BSC disk. System Responses: CREATE RSUSWLH: ULAB=, SRCPATH=, DNLALLEXE=; CREATE ACK: CREATE NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. No download in progress with this transfer identifier. NO_TASKS_AVAILABLE No free servers are available to perform the command. ABORT_BY_SYSTEM_NCK An internal system abort is occurred. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. INVALID_PARAMETER_NCK The file name is too long (a maximum of 14 characters is admitted). The object address is incorrect. The userLabel attribute already used for another RSUSWLH of the same NE type. The software version already used for another RSUSWLHof the same NE type. The NE attribute specified in the command does not exist. A30808-X3247-L230-3-7619 929 Commands Base Station Controller CML:BSC Application Guidelines: 1. A RSUSWLH can not be created if the related le has the same version of another le related to a RSUSWLH object already created. 2. A RSUSWLH can not be created if it has the same user label and Network Element of another one created. 3. The creation of a RSUSWLH instance implies the automatic creation of the related BSCESUSWor NEYESUSWinstance (depending on the fact that the software load belongs to the BSC or to BTSM/TRAU equipment). Example of Command Execution Create RSUSWLH:ULAB="Milano_Test",SRCPATH=D:\BR61\BSC\hb010140\Hb010140.swl ,DNLALLEXE=YES; DELETE RSUSWLH Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH DELETE RSUSWLH Applicability: Phase 2. Visibility level 2. Command Description: This command performs a deletion of a RSUSWLH object. The validity range of the object address rsuswlhn can be found in Appendix A. The file related to the new object is already used for another RSU object. The object is already existing but with different attributes. NO_INSTANCE_FREE The maximum number of ESUSW (NE or BSC) instances is already created. PROCESSING_ERROR_NCK The creation of the new object instance is failed. The object address is not available. OBJECT_NOT_FOUND The referenced object instance does not exist. DUPLICATED_OBJECT The involved object instance is already present. DUPLICATED_OBJECT_RSU_DISABLED The involved object instance already exists but a recovery download can be performed. DELETE RSUSWLH IDRSUSWLH=; 930 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: 1. If the RSUSWLH instance is related to a BSCESUSW or a NEYESUSW instance pointed by: backupESU, runningESU, newESU or fallbackESU attribute of BSCOSUSW or a NEYESUSW, then the deletion is not allowed. 2. The deletion of RSUSWLH object implies the deletion of all the RSUEXE objects contained into it; and consequently implies the deletion of all RSUPCH objects contained into the deleted RSUEXE. 3. After the deletion of RSUSWLH object, the related BSCESUSW or NEYESUSW objects are also deleted. Example of Command Execution Delete RSUSWLH:NAME=RSUSWLH:0; Delete RSUSWLH:IDRSUSWLH="userLabelSWLH"-BSC; GET RSUSWLH Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH GET RSUSWLH Applicability: Phase 2. Visibility level 0. DELETE ACK: DELETE NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK An internal system abort is occurred. ESU_OBJ_POINTED_BY_OSU_ATTR The related BSCESUSWobject can not be deleted (it is pointed by one of the OSUSW attributes). The related NEYESUSWobject can not be deleted (it is pointed by the backup attribute of one of the OSUSW attributes). GET RSUSWLH IDRSUSWLH= [,REQATTL=ULAB, VER, NTWEL, RELF]; A30808-X3247-L230-3-7619 931 Commands Base Station Controller CML:BSC Command Description: This command is used to retrieve the values of the different attributes of RSUSWLH object. The validity range of the object address rsuswlhn can be found in Appendix A. System Responses: Application Guidelines: If a GET RSUSWLH command is issued with a wrong USER LABEL SWLH in the IDRSUSWLH attribute, the field Object Instance of the LMT Message Browser might include a free RSUSWLH instance, rather than being n.a.. Example of Command Execution Get RSUSWLH:NAME=RSUSWLH:0,REQATTL=ULAB&VER&NTWEL&RELF; Get RSUSWLH: IDRSUSWLH="userLABELSWLH"-BSC,REQATTL=ULAB&VER&NTWEL&RELF; GET RSUSWLH BASICS Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH GET RSUSWLH BASICS GET ACK: ULAB: userLabel VER version NTWEL networkElement RELF: relatedFiles GET NACK: NACK CAUSES: NO_INSTANCE_FREE If the command is a GET RSUSWLH object instance. NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK An internal system abort is occurred. GET RSUSWLH BASICS: IDRSUSWLH; 932 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve all the attributes of the RSUSWLH object. The validity range of the object address rsuswlhn can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get RSUSWLH BASICS:NAME=RSUSWLH:0; Get RSUSWLH BASICS:IDRSUSWLH="userLabelSWLH"-BSC; GET RSUSWLH STAT Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH GET RSUSWLH STAT Applicability: Phase 2. GET ACK: VER version NTWEL networkElement RELF: relatedFiles GET NACK: NACK CAUSES: NO_INSTANCE_FREE If the command is performed with object instance request. NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK An internal system abort is occurred. GET RSUSWLH STAT: IDRSUSWLH; A30808-X3247-L230-3-7619 933 Commands Base Station Controller CML:BSC Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the RSUSWLH object: Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Unknown Status (UNK). The validity range of the object address rsuswlhn can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get RSUSWLH STAT:NAME=RSUSWLH:0; Get RSUSWLH STAT:IDRSUSWLH="userLabelSWLH"-BSC; SET RSUSWLH Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH SET RSUSWLH Applicability: Phase 2. Visibility level 2. Command Description: This command performs a change of the userLabel attribute of RSUSWLH object. The validity range of the object address rsuswlhn can be found in Appendix A. GET RSUSWLH STAT ACK: GET RSUSWLH STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_SM_TOO_BUSY The message occurs when the Status Handler task is performing the maximum number of commands. SET RSUSWLH IDRSUSWLH=, ULAB=; 934 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: If the specific userLabel value is already present the command is rejected. Example of Command Execution Set RSUSWLH:NAME=RSUSWLH:0,ULAB="userlabelNEW"; Set RSUSWLH:IDRSUSWLH="userLabelSWLH"-BSC,ULAB="userLabelNEW"; SET ACK: SET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. INVALID_PARAMETER_NCK The userLabel attribute already used for another RSUSWLH of the same NE type. OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK An internal system abort is occurred. A30808-X3247-L230-3-7619 935 Commands Base Station Controller CML:BSC SCA SCA (Smart Carrier Allocation) provides histograms of frequency based measurements and elaborates them to determine a list of ranked frequencies. This list then indicates the best substitute for a frequency that is being tested e.g. for a microcell or to be used in case of interference. The resulting reduction of interference achieved here offers benefits especially for micro cellular and pico cellular layers. The SCA object allows performing up to three newtypes of measures (Normal Measure, Busy Cumulative Measure and Extended Idle Channel Measure). The operator can choose those kind of measure types he wants to trace and also the list of frequencies to put under observation; for the Busy Cumulative Measures, the frequencies list is not required. CREATE SCA Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SCA CREATE SCA Applicability: Phase 2. Visibility level 2. Command Description: This command allows the user to create a SCAN object; this object can be created for each existing BTS. The operator must select the GSM frequency band and he also can select: the measure type, enabling the related ag; the observation period; the accumulation times (up to 4 accumulation times per day in the range 6 a.m. to 23 p.m.); the list of frequencies to be put under observation. The operator can set up to 32 frequencies for each GSM band (P, E, GSM1800, GSMR, GSM1900) and no more than one band at a time. The allowed BAND values for a given SYSID (frequency band used by the cell) are highlighted in the following table; the SYSIDparameter is defined when the user creates the BTS object. CREATE SCA: NAME=BTSM:btsmn/BTS:btsn/SCA:scan ,BAND= [,START=] [,STOP=] [,ATIME<n>=] [,ENMDL=] [,EBUSYCUM=] [,EEICM=] [,NMDLATT<nn>=] [,EICNF<nn>]; (where <n> = 1 to 4 and <nn> = 1 to 32) 936 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Validity ranges of the object addresses btsmn, btsn and scan" can be found in Appendix A. System Responses: BAND P E DCS1800 PCS1900 GSMR GSM850 BB900 X --- --- --- --- --- EXT900 X X --- --- --- --- SYSID F2ONLY X X --- --- --- --- GSMR --- --- --- --- X --- GSMDCS X X X --- --- --- DCS1800 --- --- X --- --- --- PCS1900 --- --- --- X --- --- GSM850 --- --- --- --- --- X GSM850PCS --- --- --- X --- X GSM850DCS X X Tab. 2.6 BAND and SYSID relation CREATE ACK: SUCCESSFUL CREATE NACK: NACK CAUSES: OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The superordinate objects BTSMand BTS must be already equipped. UNSUCCESSFUL_FREQ_OUT_OF_RANGE All the frequencies under observation must belong to the specified band. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. For more details see Application Guidelines n. 3, 4, 5. UNSUCCESSFUL_OVERLAPPED_PERIODS The accumulation time periods must not have intersections. UNSUCCESSFUL_FREQUENCY_ALREADY_TRACED The EICNF<nn> attributes must refer to different frequencies. UNSUCCESSFUL_BCCH_BSIC_ALREADY_TRACED The set bcchFrequency-netColorCode-bsColorCode has already been traced in an other NMDLATT<nn> parameter. FREQUENCY_NOT_ALLOWED The frequencies traced in EICNF<nn> attributes must differ fromeach other at least of more than 200 kHz. A30808-X3247-L230-3-7619 937 Commands Base Station Controller CML:BSC Application Guidelines: 1. The object is created in LOCKED state; if the object is get by BTSM it will be not equipped. To put it in service and to create it on Abis interface an unlock command is required. 2. At least one type of measure must be traced. 3. The STOP attribute must be set at a value greater or equal to the value of START. 4. The STOPTIME eld of ATIME<nn> parameter must be set at a value greater or equal to the value of STARTTIME eld. 5. If the ag ENMDL (or EEICM) is enabled the relative NMDLATT<nn> (or EICNF<nn>) measures must be set; moreover, the EICNF<nn> parameters must refer to different frequencies. 6. BTSs equipped with TPU1 cannot support the EICM Feature. Example of Command Execution Normal Measure Create SCA:NAME=BTSM:0/BTS:0/SCA:0,BAND=DCS,START=1-Jan-2001, STOP=31-Dec-2001,ATIME1=(6-0)-(8-59),ATIME2=(10-0)-(11-59), ATIME3=(13-0)-(15-59),ATIME4=(21-0)-(23-59),ENMDL=TRUE, NMDLATT1=701-0-0,NMDLATT2=701-0-0,NMDLATT3=702-0-0, NMDLATT4=703-0-0,NMDLATT5=704-0-0,NMDLATT6=705-0-0, NMDLATT7=706-0-0,NMDLATT8=707-0-0,NMDLATT9=708-0-0, NMDLATT10=709-0-0,NMDLATT11=710-0-0,NMDLATT12=711-0-0; Extended Idle Channel Measure Create SCA:NAME=BTSM:0/BTS:0/SCA:0,BAND=PCS,START=1-Jan-2001, STOP=31-Dec-2001,ATIME1=(6-0)-(10-59),ATIME2=(12-0)-(16- 59),EEICM=TRUE, EICNF1=512,EICNF2=513,EICNF3=514,EICNF4=515,EICNF5=516,EICNF6=517, EICNF7=518,EICNF8=519,EICNF9=520,EICNF10=521,EICNF11=522, EICNF12=523,EICNF13=524; Busy Cumulative Measure Create SCA:NAME=BTSM:0/BTS:0/SCA:0,BAND=P,START=1-Jan-2001, STOP=31-Dec-2001,ATIME1=(6-0)-(7-59),ATIME2=(12-0)-(13-59), ATIME3=(16-0)-(17-59),ATIME4=(21-0)-(22-59),ENMDL=FALSE, EBUSYCUM=TRUE,EEICM=FALSE; UNSUCCESSFUL_BAND_INCONSISTENT The selected band is not consistent with the SYSID used by the cell (see Tab. 2.6). UNSUCCESSFUL_INVALID_BCCH_FREQUENCY The BCCH frequency specified in the NMDLATT<nn> attribute must belong to an existent ADJC of the cell related to the SCA. 938 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DELETE SCA Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SCA DELETE SCA Applicability: Phase 2. Visibility level 2. Command Description: The command deletes a SCA instance which has been previously created. Validity ranges of the object addresses btsmn, btsn and scan" can be found in Appendix A. System Responses: Application Guidelines: When the state of the SCA object is set at LOCK the relative measurement results will be deleted on BTS, so the operator has to give first an UPLOADREQ SCA command if he does not want to lose any information. Example of Command Execution Delete SCA:NAME=BTSM:0/BTS:0/SCA:0; GET SCA Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SCA GET SCA DELETE SCA: NAME=BTSM:btsmn/BTS:btsn/SCA:scan; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a SCA, the relative object instance must be in LOCKED state. GET SCA: NAME=BTSM:btsmn/BTS:btsn/SCA:scan [,REQATTL= BAND, START, STOP, ATIME<n>, ENMDL, EBUSYCUM, EEICM, NMDLATT<nn>, EICNF<nn>]; (where <n>= 1 to 4 and <nn> = 1 to 32) A30808-X3247-L230-3-7619 939 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the values of the parameters selected by the operators by means of REQATTL field. Validity ranges of the object addresses btsmn, btsn and scan" can be found in Appendix A. System Responses: GET ACK SCAN: NAME: name BAND: band START: startDate STOP: stopDate ATIME1: accumulationTime1 ATIME2: accumulationTime2 ATIME3: accumulationTime3 ATIME4: accumulationTime4 ENMDL: enableNormalMeas EBUSYCUM: enableBusyCumulMeas EEICM: enableExtIdleMeas NMDLATT1: normalMeasAttr1 NMDLATT2: normalMeasAttr2 NMDLATT3: normalMeasAttr3 NMDLATT4: normalMeasAttr4 NMDLATT5: normalMeasAttr5 NMDLATT6: normalMeasAttr6 NMDLATT7: normalMeasAttr7 NMDLATT8: normalMeasAttr8 NMDLATT9: normalMeasAttr9 NMDLATT10: normalMeasAttr10 NMDLATT11: normalMeasAttr11 NMDLATT12: normalMeasAttr12 NMDLATT13: normalMeasAttr13 NMDLATT14: normalMeasAttr14 NMDLATT15: normalMeasAttr15 NMDLATT16: normalMeasAttr16 NMDLATT17: normalMeasAttr17 NMDLATT18: normalMeasAttr18 NMDLATT19: normalMeasAttr19 NMDLATT20: normalMeasAttr20 NMDLATT21: normalMeasAttr21 NMDLATT22: normalMeasAttr22 NMDLATT23: normalMeasAttr23 NMDLATT24: normalMeasAttr24 940 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. NMDLATT25: normalMeasAttr25 NMDLATT26: normalMeasAttr26 NMDLATT27: normalMeasAttr27 NMDLATT28: normalMeasAttr28 NMDLATT29: normalMeasAttr29 NMDLATT30: normalMeasAttr30 NMDLATT31: normalMeasAttr31 EICNF1: extIdleChanFreq1 EICNF2: extIdleChanFreq2 EICNF3: extIdleChanFreq3 EICNF4: extIdleChanFreq4 EICNF5: extIdleChanFreq5 EICNF6: extIdleChanFreq6 EICNF7: extIdleChanFreq7 EICNF8: extIdleChanFreq8 EICNF9: extIdleChanFreq9 EICNF10: extIdleChanFreq10 EICNF11: extIdleChanFreq11 EICNF12: extIdleChanFreq12 EICNF13: extIdleChanFreq13 EICNF14: extIdleChanFreq14 EICNF15: extIdleChanFreq15 EICNF16: extIdleChanFreq16 EICNF17: extIdleChanFreq17 EICNF18: extIdleChanFreq18 EICNF19: extIdleChanFreq19 EICNF20: extIdleChanFreq20 EICNF21: extIdleChanFreq21 EICNF22: extIdleChanFreq22 EICNF23: extIdleChanFreq23 EICNF24: extIdleChanFreq24 EICNF25: extIdleChanFreq25 EICNF26: extIdleChanFreq26 EICNF27: extIdleChanFreq27 EICNF28: extIdleChanFreq28 EICNF29: extIdleChanFreq29 EICNF30: extIdleChanFreq30 EICNF31: extIdleChanFreq31 EICNF32: extIdleChanFreq32 GET NACK NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 941 Commands Base Station Controller CML:BSC Example of Command Execution Get SCA:NAME=BTSM:0/BTS:0/SCA:0,REQATTL=BAND&START&STOP& ATIME1& ATIME2&ATIME3&ATIME4&ENMDL&EBUSYCUM&EEICM&NMDLATT1& NMDLATT2&NMDLATT3&NMDLATT4&NMDLATT5&NMDLATT6&NMDLATT7& NMDLATT8&NMDLATT9&NMDLATT10&NMDLATT11&NMDLATT12&NMDLATT13& NMDLATT14&NMDLATT15&NMDLATT16&NMDLATT17&NMDLATT18& NMDLATT19&NMDLATT20&NMDLATT21&NMDLATT22&NMDLATT23& NMDLATT24&NMDLATT25&NMDLATT26&NMDLATT27&NMDLATT28& NMDLATT29&NMDLATT30&NMDLATT31&NMDLATT32&EICNF1&EICNF2& EICNF3&EICNF4&EICNF5&EICNF6&EICNF7&EICNF8&EICNF9&EICNF10& EICNF11&EICNF12&EICNF13&EICNF14&EICNF15&EICNF16&EICNF17&EICNF18& EICNF19&EICNF20&EICNF21&EICNF22&EICNF23&EICNF24&EICNF25&EICNF26& EICNF27&EICNF28&EICNF29&EICNF30&EICNF31&EICNF32; GET SCA BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SCA GET SCA BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses btsmn, btsn and scan" can be found in Appendix A. System Responses: GET SCA BASICS: NAME=BTSM:btsmn/BTS:btsn/SCA:scan; GET ACK SCAN: NAME: name BAND: band START: startDate STOP: stopDate ATIME1: accumulationTime1 ATIME2: accumulationTime2 ATIME3: accumulationTime3 ATIME4: accumulationTime4 ENMDL: enableNormalMeas EBUSYCUM: enableBusyCumulMeas EEICM: enableExtIdleMeas GET NACK: 942 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get SCA BASICS:NAME=BTSM:0/BTS:0/SCA:0; GET SCA EICM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SCA GET SCA EICM Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the EICM group. Validity ranges of the object addresses btsmn, btsn and scan" can be found in Appendix A. System Responses: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCA EICM: NAME=BTSM:btsmn/BTS:btsn/SCA:scan; GET ACK SCAN: NAME: name EICNF1: extIdleChanFreq1 EICNF2: extIdleChanFreq2 EICNF3: extIdleChanFreq3 EICNF4: extIdleChanFreq4 EICNF5: extIdleChanFreq5 EICNF6: extIdleChanFreq6 EICNF7: extIdleChanFreq7 EICNF8: extIdleChanFreq8 EICNF9: extIdleChanFreq9 EICNF10: extIdleChanFreq10 EICNF11: extIdleChanFreq11 EICNF12: extIdleChanFreq12 EICNF13: extIdleChanFreq13 EICNF14: extIdleChanFreq14 EICNF15: extIdleChanFreq15 EICNF16: extIdleChanFreq16 A30808-X3247-L230-3-7619 943 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get SCA EICM:NAME=BTSM:0/BTS:0/SCA:0; GET SCA NMDL Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SCA GET SCA NMDL Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the NMDL group. Validity ranges of the object addresses btsmn, btsn and scan" can be found in Appendix A. EICNF17: extIdleChanFreq17 EICNF18: extIdleChanFreq18 EICNF19: extIdleChanFreq19 EICNF20: extIdleChanFreq20 EICNF21: extIdleChanFreq21 EICNF22: extIdleChanFreq22 EICNF23: extIdleChanFreq23 EICNF24: extIdleChanFreq24 EICNF25: extIdleChanFreq25 EICNF26: extIdleChanFreq26 EICNF27: extIdleChanFreq27 EICNF28: extIdleChanFreq28 EICNF29: extIdleChanFreq29 EICNF30: extIdleChanFreq30 EICNF31: extIdleChanFreq31 EICNF32: extIdleChanFreq32 GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCA NMDL: NAME=BTSM:btsmn/BTS:btsn/SCA:scan; 944 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Get SCA NMDL:NAME=BTSM:0/BTS:0/SCA:0; GET ACK SCAN: NAME: name NMDLATT1: normalMeasAttr1 NMDLATT2: normalMeasAttr2 NMDLATT3: normalMeasAttr3 NMDLATT4: normalMeasAttr4 NMDLATT5: normalMeasAttr5 NMDLATT6: normalMeasAttr6 NMDLATT7: normalMeasAttr7 NMDLATT8: normalMeasAttr8 NMDLATT9: normalMeasAttr9 NMDLATT10: normalMeasAttr10 NMDLATT11: normalMeasAttr11 NMDLATT12: normalMeasAttr12 NMDLATT13: normalMeasAttr13 NMDLATT14: normalMeasAttr14 NMDLATT15: normalMeasAttr15 NMDLATT16: normalMeasAttr16 NMDLATT17: normalMeasAttr17 NMDLATT18: normalMeasAttr18 NMDLATT19: normalMeasAttr19 NMDLATT20: normalMeasAttr20 NMDLATT21: normalMeasAttr21 NMDLATT22: normalMeasAttr22 NMDLATT23: normalMeasAttr23 NMDLATT24: normalMeasAttr24 NMDLATT25: normalMeasAttr25 NMDLATT26: normalMeasAttr26 NMDLATT27: normalMeasAttr27 NMDLATT28: normalMeasAttr28 NMDLATT29: normalMeasAttr29 NMDLATT30: normalMeasAttr30 NMDLATT31: normalMeasAttr31 GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 945 Commands Base Station Controller CML:BSC GET SCA STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SCA GET SCA STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SCA object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Unknown Status (UNK). Validity ranges of the object addresses btsmn, btsn and scan" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCA STAT:NAME=BTSM:0/BTS:0/SCA:0; LOCK SCA Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SCA LOCK SCA GET SCA STAT: NAME=BTSM:btsmn/BTS:btsn/SCA:scan; GET SCA STAT ACK: GET SCA STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK SCA: NAME=BTSM:btsmn/BTS:btsn/SCA:scan; 946 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". Validity ranges of the object addresses btsmn, btsn and scan" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock SCA:NAME=BTSM:0/BTS:0/SCA:0 SET SCA Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SCA SET SCA Applicability: Phase 2. Visibility level 2. Command Description: This command allows to the user to change the setting related to a SCAN object preiously cretaed. LOCK SCA ACK: LOCK SCA NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SET SCA: NAME=BTSM:btsmn/BTS:btsn/SCA:scan [,START=] [,STOP=] [,ATIME<n>=] [,ENMDL=] [,EBUSYCUM=] [,EEICM=] [,NMDLATT<nn>=] [,EICNF<nn>]; (where <n>= 1 to 4 and <nn> = 1 to 32) A30808-X3247-L230-3-7619 947 Commands Base Station Controller CML:BSC Validity ranges of the object addresses btsmn, btsn and scan" can be found in Appendix A. System Responses: Application Guidelines: 1. At least one type of measure must be traced. 2. The STOP attribute must be set at a value greater or equal to the value of START. 3. The STOPTIME eld of ATIME<nn> parameter must be set at a value greater or equal to the value of STARTTIME eld. 4. If the ag ENMDL (or EBUSYCUM) is enabled the relative NMDLATT<nn> (or EICNF<nn>) measures must be set; moreover, the EICNF<nn> parameters must refer to different frequencies. 5. BTSs equipped with TPU1 cannot support the EICM feature. Example of Command Execution Set SCA:NAME=BTSM:0/BTS:0/SCA:0,BAND=DCS,START=1-Jan-2001, STOP=31- Dec-2001,ATIME1=(6-0)-(8-59),ATIME2=(10-0)-(11-59), ATIME3=(13-0)-(15-59),ATIME4=(21-0)-(23-59),ENMDL=TRUE, NMDLATT1=701-0-0,NMDLATT2=701-0-0,NMDLATT3=702-0-0, NMDLATT4=703-0-0,NMDLATT5=704-0-0,NMDLATT6=705-0-0, NMDLATT7=706-0-0,NMDLATT8=707-0-0,NMDLATT9=708-0-0, NMDLATT10=709-0-0,NMDLATT11=710-0-0,NMDLATT12=711-0-0; SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_STATUS In order to set the selected object it must be in LOCKED state. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_FREQ_OUT_OF_RANGE All the frequencies under observation must belong to the specified band. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. UNSUCCESSFUL_OVERLAPPED_PERIODS The accumulation time periods must not have intersections. UNSUCCESSFUL_FREQUENCY_ALREADY_TRACED The EICNF<nn> attributes must refer to different frequencies. UNSUCCESSFUL_BCCH_BSIC_ALREADY_TRACED The set bcchFrequency-netColorCode-bsColorCode has already been traced in an other NMDLATT<nn> parameter. FREQUENCY_NOT_ALLOWED The frequencies traced in EICNF<nn> attributes must differ fromeach other at least of more than 200 kHz. UNSUCCESSFUL_INVALID_BCCH_FREQUENCY The BCCH frequency specified in the NMDLATT<nn> attribute must belong to an existent ADJC of the cell related to the SCA. 948 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller UNLOCK SCA Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SCA UNLOCK SCA Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". Validity ranges of the object addresses btsmn, btsn and scan" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock SCAN:NAME=SCAN:0; UPLOADREQ SCA Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SCA UPLOADREQ SCA Applicability: Phase 2. Visibility level 1. UNLOCK SCA: NAME=BTSM:btsmn/BTS:btsn/SCA:scan; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The selected object is not created. UPLOADREQ SCA: NAME=BTSM:btsmn/BTS:btsn/SCA:scan,DESTDIR= , OVERWRITE= ; A30808-X3247-L230-3-7619 949 Commands Base Station Controller CML:BSC Command Description: This command allows the user to upload the measure files fromthe BSCdisk to the LMT disk; the destination directory, the file name and the file overwriting (or not) must be defined by the user. Validity ranges of the object addresses btsmn, btsn and scan" can be found in Appendix A. System Responses: Application Guidelines: 1. If the scannerlogle is uploaded with OVERWRITE parameter set at NOand the le already exists on the LMT disk, the LMT renames the existing one to oldfilename_DayMonthYearHourMinute.Thesameextention and stores the uploaded one to the disk. 2. If the user aborts the upload command or the link (between LMT and BSC) falls down, then it is no more possible to upload the same le: a new measure le will be created until new log les will be produced inside BSC. Example of Command Execution Uploadreq SCA:NAME=BTSM:0/BTS:0/SCA:0,DESTDIR="C:\Siemens", FILE="Test_measure",OVERWRITE=YES; UPLOADREQ ACK: UPLOADREQ NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before launching this command, the relative object instance must be in LOCKED state. According to the configured stopDate field value, measurement data collection is finished (i.e. the stopDate has been reached): the upload cannot be executed since measures are not present in the BTS equip- ment. 950 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SCANAIRTSTD The SCANAIRTSTD (Scanner AIRTSTD) is a scanning function on a specific set of AIR TS of the BTSTD managed objects, and is able to report periodically the collected measurements; the raw data are collected at BSC. ADD SCANAIRTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANAIRTSTD ADD SCANAIRTSTD Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add measures and objects to the original configuration of a scanner previously created by the user. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. ADD SCANAIRTSTD: NAME=SCANAIRTSTD:scantdn, MEASOBJLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object have been already configured in an other scanner. WRONG_LIST_OF_MEASURE Some measures are already present inside the scanner measures list. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. Scanner is in selfAdapting mode or exceeded max number of objects. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. A30808-X3247-L230-3-7619 951 Commands Base Station Controller CML:BSC Example of Command Execution Add SCANAIRTSTD:NAME=SCANAIRTSTD:0,MEASOBJLST=measList(TDTAC- CBPRO | TDNACSUCPR | TDSUIMASCA | TDATINHIRC); CREATE SCANAIRTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANAIRTSTD CREATE SCANAIRTSTD Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the SCANAIRTSTD object. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: CREATE SCANAIRTSTD: NAME=SCANAIRTSTD:scantdn, MEASLST= ,OBJLST= [,GRANP=] [,START=] [,STOP=] ,RECINT= [,UTRANRSCPR] [,UERSCPR] [,UTRAN- TSISCPR] [,UETSISCPR] [,RSSILVR] [,TCHBLERR] [,UTRANTXCPR] [,UTRANTXPR] [,UETXPR] [,TCHBERR] ; CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANAIRTSTD:istn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCANAIRTSTD: name = SCANAIRTSTD:istn commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created . UNSUCCESSFUL_INVALID_STATUS 952 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller The measurements have to be applied to already created object instances; after the creation of the object the ADMINISTRATIVE state is UNLOCKED UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in another scanner. UNSUCCESSFUL_LIST_OF_OBJECT The OBJLST contains the same object more times. UNSUCCESSFUL_INVALID_DATE The start date or the stop date are incorrect. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. WRONG_LIST_OF_MEASURE Only one measure can be configured on the same scanner; the same measure cannot be configured on different AIRTSTD belonging to the same TRXTD and on the TRXTD itself. The measure list cannot be empty. UNSUCCESSFUL_WRONG_UTRANRSCPR_RANGE For UTRANRSCPR the following rules must be fulfilled: Inputvalue1 < Inputvalue2 < Inputvalue3 < Inputvalue4 < Inputvalue5 <Inputvalue6 < Inputvalue7 UNSUCCESSFUL_WRONG_UERSCPR_RANGE For UERSCPR the following rules must be fulfilled: Inputvalue1 < Inputvalue2 < Inputvalue3 < Inputvalue4 < Inputvalue5 <Inputvalue6 < Inputvalue7 UNSUCCESSFUL_WRONG_UTRANTSISCPR_RANGE For UTRANTSISCPR the following rules must be fulfilled: Inputvalue1 < Inputvalue2 < Inputvalue3 < Inputvalue4 < Inputvalue5 <Inputvalue6 < Inputvalue7 UNSUCCESSFUL_WRONG_UETSISCPR_RANGE For UETSISCPR the following rules must be fulfilled: Inputvalue1 < Inputvalue2 < Inputvalue3 < Inputvalue4 < Inputvalue5 <Inputvalue6 < Inputvalue7 UNSUCCESSFUL_WRONG_RSSILVR_RANGE A30808-X3247-L230-3-7619 953 Commands Base Station Controller CML:BSC Application Guidelines: When a Restart of BSC is done, the Perfomance Measurements Data collected in the last granularity are not signicant. PM generation report follows the next rules: Reports contain only already created objects counters. If all objects under measure are not already created, a report with objects number equal to zero is always gener- ated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution Create SCANAIRTSTD:NAME=SCANAIRTSTD:0,MEASLST=TDUETSISCP, OBJLST=0-0-0-0&0-0-0-1&0-0-0-2&0-0-0-3&0-0-0-4&0-0-0-5&0-0-0-6&-0&-0&- 0,GRANP=MINUTES_30,START=1-Jan-2003,STOP=1-Mar-2003,RECINT=all(0), RSSILVR=7&15&23&31&39&47&55, TCHBLERR=7&15&23&31&39&47&55, TCHBERR=7&15&23&31&39&47&55; DELETE SCANAIRTSTD For RSSILVR the following rules must be fulfilled: Inputvalue1 < Inputvalue2 < Inputvalue3 < Inputvalue4 < Inputvalue5 <Inputvalue6 < Inputvalue7 UNSUCCESSFUL_WRONG_TCHBLERR_RANGE For TCHBLERR the following rules must be fulfilled: Inputvalue1 < Inputvalue2 < Inputvalue3 < Inputvalue4 < Inputvalue5 <Inputvalue6 < Inputvalue7 UNSUCCESSFUL_WRONG_UTRANTXCPR_RANGE For UTRANTXCPR the following rules must be fulfilled: Inputvalue1 < Inputvalue2 < Inputvalue3 < Inputvalue4 < Inputvalue5 <Inputvalue6 < Inputvalue7 UNSUCCESSFUL_WRONG_UTRANTXPR_RANGE For UTRANTXPR the following rules must be fulfilled: Inputvalue1 < Inputvalue2 < Inputvalue3 < Inputvalue4 < Inputvalue5 <Inputvalue6 < Inputvalue7 UNSUCCESSFUL_WRONG_UETXPR_RANGE For UETXPR the following rules must be fulfilled: Inputvalue1 < Inputvalue2 < Inputvalue3 < Inputvalue4 < Inputvalue5 <Inputvalue6 < Inputvalue7 UNSUCCESSFUL_WRONG_TCHBERR_RANGE For TCHBERR the following rules must be fulfilled: Inputvalue1 < Inputvalue2 < Inputvalue3 < Inputvalue4 < Inputvalue5 <Inputvalue6 < Inputvalue7 UNSUCCESSFUL_VAR_OUT_OF_RANGE Max number of scanner exceeded. DELETE SCANAIRTSTD: NAME=SCANAIRTSTD:scantdn; 954 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANAIRTSTD DELETE SCANAIRTSTD Applicability: Phase 2. Visibility level 2. Command Description: The command deletes a scanner instance which has been previously created. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete SCANAIRTSTD:NAME=SCANAIRTSTD:0; DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. A30808-X3247-L230-3-7619 955 Commands Base Station Controller CML:BSC GET SCANAIRTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANAIRTSTD GET SCANAIRTSTD Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: GET SCANAIRTSTD: NAME=SCANAIRTSTD:scantdn [,REQATTL=MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, UTRANRSCPR, UERSCPR, UTRANTSISCPR, UETSISCPR, RSSILVR, TCHBLERR, UTRANTXCPR, UTRANTXPR, UETXPR, TCHBERR, LSUPDTIME, LSLOTIME, LSULO- TIME]; GET ACK: NAME: SCANAIRTSTD MEASLST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval UTRANRSCPR: utranRscpRange UERSCPR: ueRscpRange UTRANTSISCPR: utranTsIscpRange UETSISCPR: ueTsIscpRange RSSILVR: rssiLevelRange TCHBLERR: tchBlerRange UTRANTXCPR: utranTxCodePowerRange UTRANTXPR: utranTxPowerRange UETXPR: ueTxPowerRange TCHBERR: tchBerRange LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: 956 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get SCANAIRTSTD:NAME=SCANAIRTSTD:0,REQATTL=MEASLST&OBJLST& GRANP&REPMETHD&START&STOP&RECINT&UTRANR- SCPR&UERSCPR&UTRAN- TSISCPR&UETSISCPR&RSSILVR&TCHBLERR&UTRANTXCPR&UTRANTXPR&UE TXPR&TCHBERR&LSUPDTIME&LSLOTIME&LSULOTIME; GET SCANAIRTSTD BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANAIRTSTD GET SCANAIRTSTD BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. GET SCANAIRTSTD BASICS: NAME=SCANAIRTSTD:scantdn; GET ACK: NAME: SCANAIRTSTD MEASLST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval UTRANRSCPR: utranRscpRange UERSCPR: ueRscpRange UTRANTSISCPR: utranTsIscpRange UETSISCPR: ueTsIscpRange RSSILVR: rssiLevelRange A30808-X3247-L230-3-7619 957 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get SCANAIRTSTD BASICS:NAME=SCANAIRTSTD:0; GET SCANAIRTSTD STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANAIRTSTD GET SCANAIRTSTD STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SCANAIRTSTD object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "scantdn" can be found in Appendix A. TCHBLERR: tchBlerRange UTRANTXCPR: utranTxCodePowerRange UTRANTXPR: utranTxPowerRange UETXPR: ueTxPowerRange TCHBERR: tchBerRange LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. GET SCANAIRTSTD STAT: NAME=SCANAIRTSTD:scantdn; 958 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Get SCANAIRTSTD STAT:NAME=SCANAIRTSTD:0; LOCK SCANAIRTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANAIRTSTD LOCK SCANAIRTSTD Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). GET SCANAIRTSTD STAT ACK: GET SCANAIRTSTD STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. LOCK SCANAIRTSTD: NAME=SCANAIRTSTD:scantdn; LOCK SCANAIRTSTD ACK: LOCK SCANAIRTSTD NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. A30808-X3247-L230-3-7619 959 Commands Base Station Controller CML:BSC Example of Command Execution Lock SCANAIRTSTD:NAME=SCANAIRTSTD:0; REMOVE SCANAIRTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANAIRTSTD REMOVE SCANAIRTSTD Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove measures and objects from the original configuration of a scanner previously created by the user. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Remove SCANAIRTSTD:NAME=SCANAIRTSTD:0,MEASOBJLST=0-0-0-0&0-0-0- 1&0-0-0-2&0-0-0-3&0-0-0-4&0-0-0-5&0-0-0-6; REMOVE SCANAIRTSTD: NAME=SCANAIRTSTD:scantdn, MEASOBJLST=; REMOVE ACK: SUCCESSFUL REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. UNSUCCESSFUL_LIST_OF_OBJECT The object in MEASOBJLST is not present in the database or only one object in the allowed range of values. WRONG_LIST_OF_MEASURE The measure in MEASOBJLST is not present in database or only one measure in the allowed range of values. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. 960 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SET SCANAIRTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANAIRTSTD SET SCANAIRTSTD Applicability: Phase 2. Visibility level 2. Command Description: This command is used to change the parameter values, previously defined by the user by means of a create command, for the instance scantdn of the SCANAIRTSTD object. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: SET SCANAIRTSTD: NAME=SCANAIRTSTD:scantdn [,MEASLST=] [,OBJLST=] [,GRANP=] [,START=] [,STOP=] [,RECINT=] [,UTRANRSCPR] [,UERSCPR] [,UTRAN- TSISCPR] [,UETSISCPR] [,RSSILVR] [,TCHBLERR] [,UTRANTXCPR] [,UTRANTXPR] [,UETXPR] [,TCHBERR]; SET ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANAIRTSTD: name = SCANAIRTSTD:<istn> SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created . UNSUCCESSFUL_INVALID_STATUS The measurements have to be applied to already created object instances; after the creation of the object the ADMINISTRATIVE state is UNLOCKED UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in another scanner. UNSUCCESSFUL_LIST_OF_OBJECT The OBJLST contains the same object more times. UNSUCCESSFUL_INVALID_DATE The start date or the stop date are incorrect. UNSUCCESSFUL_TIMEFRAME_INCORRECT A30808-X3247-L230-3-7619 961 Commands Base Station Controller CML:BSC The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. WRONG_LIST_OF_MEASURE Only one measure can be configured on the same scanner; the same measure cannot be configured on different AIRTSTD belonging to the same TRXTD and on the TRXTD itself. The measure list cannot be empty. UNSUCCESSFUL_WRONG_UTRANRSCPR_RANGE For UTRANRSCPR the following rules must be fulfilled: Inputvalue1 < Inputvalue2 < Inputvalue3 < Inputvalue4 < Inputvalue5 <Inputvalue6 < Inputvalue7 UNSUCCESSFUL_WRONG_UERSCPR_RANGE For UERSCPR the following rules must be fulfilled: Inputvalue1 < Inputvalue2 < Inputvalue3 < Inputvalue4 < Inputvalue5 <Inputvalue6 < Inputvalue7 UNSUCCESSFUL_WRONG_UTRANTSISCPR_RANGE For UTRANTSISCPR the following rules must be fulfilled: Inputvalue1 < Inputvalue2 < Inputvalue3 < Inputvalue4 < Inputvalue5 <Inputvalue6 < Inputvalue7 UNSUCCESSFUL_WRONG_UETSISCPR_RANGE For UETSISCPR the following rules must be fulfilled: Inputvalue1 < Inputvalue2 < Inputvalue3 < Inputvalue4 < Inputvalue5 <Inputvalue6 < Inputvalue7 UNSUCCESSFUL_WRONG_RSSILVR_RANGE For RSSILVR the following rules must be fulfilled: Inputvalue1 < Inputvalue2 < Inputvalue3 < Inputvalue4 < Inputvalue5 <Inputvalue6 < Inputvalue7 UNSUCCESSFUL_WRONG_TCHBLERR_RANGE For TCHBLERR the following rules must be fulfilled: Inputvalue1 < Inputvalue2 < Inputvalue3 < Inputvalue4 < Inputvalue5 <Inputvalue6 < Inputvalue7 UNSUCCESSFUL_WRONG_UTRANTXCPR_RANGE For UTRANTXCPR the following rules must be fulfilled: Inputvalue1 < Inputvalue2 < Inputvalue3 < Inputvalue4 < Inputvalue5 <Inputvalue6 < Inputvalue7 UNSUCCESSFUL_WRONG_UTRANTXPR_RANGE 962 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: When a Restart of BSC is done, the Perfomance Measurements Data collected in the last granularity are not signicant. PM generation report follows the next rules: Reports contain only already created objects counters. If all objects under measure are not already created, a report with objects number equal to zero is always gener- ated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution Set SCANAIRTSTD:NAME=SCANAIRTSTD:0,MEASLST=TDUETSISCP,OBJLST=0- 0-0-0&0-0-0-1&0-0-0-2&0-0-0-3&0-0-0-4&0-0-0-5&0-0-0-6&-0&-0&-0,GRANP= MINUTES_30,START=1-Jan-2003,STOP=1-Mar-2003,RECINT=all(0), RSSILVR=7&15&23&31&39&47&55, TCHBLERR=7&15&23&31&39&47&55, TCHBERR=7&15&23&31&39&47&55; UNLOCK SCANAIRTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANAIRTSTD UNLOCK SCANAIRTSTD Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scantdn" can be found in Appendix A. For UTRANTXPR the following rules must be fulfilled: Inputvalue1 < Inputvalue2 < Inputvalue3 < Inputvalue4 < Inputvalue5 <Inputvalue6 < Inputvalue7 UNSUCCESSFUL_WRONG_UETXPR_RANGE For UETXPR the following rules must be fulfilled: Inputvalue1 < Inputvalue2 < Inputvalue3 < Inputvalue4 < Inputvalue5 <Inputvalue6 < Inputvalue7 UNSUCCESSFUL_WRONG_TCHBERR_RANGE For TCHBERR the following rules must be fulfilled: Inputvalue1 < Inputvalue2 < Inputvalue3 < Inputvalue4 < Inputvalue5 <Inputvalue6 < Inputvalue7 UNSUCCESSFUL_VAR_OUT_OF_RANGE Max number of scanner exceeded. UNLOCK SCANAIRTSTD: NAME=SCANAIRTSTD:scantdn; A30808-X3247-L230-3-7619 963 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Unlock SCANAIRTSTD:NAME=SCANAIRTSTD:0; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. 964 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SCANBSC The SCANBSC (Scanner BSC) represents a scanning function on a BSC managed object, and is able to report periodically the collected measurements. ACTIVATE SCANBSC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBSC ACTIVATE SCANBSC Applicability: Phase 2. Visibility level 2. Command Description: This command provides a report of the partial results, collected after the last report, related to the instance. The report mode has been already selected in the configuration phase. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Activate SCANBSC:NAME=SCANBSC:0; ACTIVATE SCANBSC: NAME=SCANBSC:scann; ACTIVATE ACK: ACTIVATE NACK: NACK CAUSES: REJECTED_OTHER_COMMAND_IN_PROGRESS System busy in another PM report generation. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Scanner object is not ON_DUTY. A30808-X3247-L230-3-7619 965 Commands Base Station Controller CML:BSC ADD SCANBSC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBSC ADD SCANBSC Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Add SCANBSC:NAME=SCANBSC:0,MEASOBJLST=SINHOBSC | TMSGREC | TMSHHDL; ADD SCANBSC: NAME=SCANBSC:scann, MEASOBJLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. WRONG_LIST_OF_MEASURE Trying to add a measure already present inside scanner measures list. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object have been already configured in an other scanner. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. 966 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller CREATE SCANBSC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBSC CREATE SCANBSC Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the SCANBSC object. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: CREATE SCANBSC: NAME=SCANBSC:scann, MEASLST=[,GRANP=] [,REPMETHD=] [,START=] [,STOP=] ,RECINT=; CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANBSC:istn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCAN: name = SCANBSC:istn commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: UNSUCCESSFUL_VAR_OUT_OF_RANGE Max number of scanner exceeded. UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. UNSUCCESSFUL_POOL_EXHAUSTED The number of scanner BYMSG is greater than the limitation defined (10). A30808-X3247-L230-3-7619 967 Commands Base Station Controller CML:BSC Application Guidelines: PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution Create SCANBSC:NAME=SCANBSC:0,MEASLST=measList(DLKUNCON | SINHOBSC | NRINHDFL | LOCAUTCH | NASPAVUN | DASPUNT | BSCPRCLD),GRANP=MINUTES_5,REPMETHD=BYMSG,START=1-Jan-2001, STOP=1-Dec-2001,RECINT=daily(1-00-3-59&10-00-12-59&23-4-22-59&8-00-11- 10&14-00-14-59&15-00-18-59&20-00-21-59); DELETE SCANBSC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBSC DELETE SCANBSC Applicability: Phase 2. Visibility level 2. Command Description: The command deletes a scanner instance which has been previously created. The validity range of the object address "scann" can be found in Appendix A. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. DELETE SCANBSC: NAME=SCANBSC:scann; 968 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Delete SCANBSC:NAME=SCANBSC:0; GET SCANBSC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBSC GET SCANBSC Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. The validity range of the object address "scann" can be found in Appendix A. System Responses: DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a SCANBSC, the relative object instance must be in LOCKED state. GET SCANBSC: NAME=SCANBSC:scann [,REQATTL=MEASLST,GRANP, REPMETHD, START, STOP, RECINT, LSUPDTIME, LSLOTIME, LSULOTIME]; GET ACK: NAME: SCANBSC MEASLIST: measureList A30808-X3247-L230-3-7619 969 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get SCANBSC:NAME=SCANBSC:0,REQATTL=MEASLST&GRANP&REPMETHD& START&STOP&RECINT&LSUPDTIME&LSLOTIME&LSULOTIME; GET SCANBSC BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBSC GET SCANBSC BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "scann" can be found in Appendix A. System Responses: GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANBSC BASICS: NAME=SCANBSC:scann; GET SCANBSC BASIC ACK: NAME: SCANBSC MEASLIST: measureList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate 970 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get SCANBSC BASICS:NAME=SCANBSC:0; GET SCANBSC STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBSC GET SCANBSC STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SCANBSC object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "scann" can be found in Appendix A. System Responses: RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET SCANBSC BASIC NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANBSC STAT: NAME=SCANBSC:scann; GET SCANBSC STAT ACK: GET SCANBSC STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 971 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get SCANBSC STAT:NAME=SCANBSC:0; LOCK SCANBSC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBSC LOCK SCANBSC Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock SCANBSC:NAME=SCANBSC:0; LOCK SCANBSC: NAME=SCANBSC:scann; LOCK SCANBSC ACK: LOCK SCANBSC NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 972 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller REMOVE SCANBSC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBSC REMOVE SCANBSC Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Remove SCANBSC:NAME=SCANBSC:0,MEASOBJLST=RFSUBUN; SET SCANBSC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBSC SET SCANBSC REMOVE SCANBSC: NAME=SCANBSC:scann, MEASOBJLST=; REMOVE ACK: Successful REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. WRONG_LIST_OF_MEASURE Measure not present or only one measure within database. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. SET SCANBSC: NAME=SCANBSC:scann [,MEASLST=] [,GRANP=] [,REPMETHD=] [,START=] [,STOP=] [,RECINT=]; A30808-X3247-L230-3-7619 973 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 2. Command Description: This command sets the configuration of instance of the SCANBSCobjct. The parameter specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. SET ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANBSC: name = SCANBSC:<istn> commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. UNSUCCESSFUL_POOL_EXHAUSTED The number of scanner BYMSG is greater than the limitation defined (10). UNSUCCESSFUL_TIMEFRAME_INCORRECT Start date > stop date. UNSUCCESSFUL_TIMEFRAME_ELAPSED Actual date > stop date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START Period start is not a multiple of granularity. UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. 974 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Set SCANBSC:NAME=SCANBSC:0,MEASLST=allMeas(0),GRANP=MINUTES_60, REPMETHD=BYFILE,START=1-Jan-2001,STOP=1-Dec-2001,RECINT=all(0); UNLOCK SCANBSC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBSC UNLOCK SCANBSC Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock SCANBSC:NAME=SCANBSC:0; UNLOCK SCANBSC: NAME=SCANBSC:scann; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 975 Commands Base Station Controller CML:BSC SCANBTS The SCANBTS (Scanner BTS) is a scanning function on a specific set of BTS managed objects, and is able to report periodically the collected measurements; the raw data are collected at BSC. ADD SCANBTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTS ADD SCANBTS Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: ADD SCANBTS: NAME=SCANBTS:scann, MEASOBJLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_WRONG_GRANULARITY With MEASLIST=measlist(MBTCHCHT) the GRANP must be at least MINUTE_15. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object have been already configured in an other scanner. WRONG_LIST_OF_MEASURE Trying to add a measure already present inside scanner measures list. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. Scanner is in selfAdapting mode or exceeded max number of objects. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. 976 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Add SCANBTS:NAME=SCANBTS:0,MEASOBJLST=measList(NRFLSDCC | SINTHITA | TACCBPRO); CREATE SCANBTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTS CREATE SCANBTS Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the SCANBTS object. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: CREATE SCANBTS: NAME=SCANBTS:scann, MEASLST= ,OBJLST= [,GRANP=] [,START=] [,STOP=] ,RECINT=; CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANBTS:istn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCANBTS: name = SCANBTS:istn commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: UNSUCCESSFUL_VAR_OUT_OF_RANGE Max number of scanner exceeded. UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. A30808-X3247-L230-3-7619 977 Commands Base Station Controller CML:BSC Application Guidelines: PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution Create SCANBTS:NAME=SCANBTS:0,MEASLST=allMeas(0), OBJLST=selfAdapting(0),GRANP=MINUTES_15,START=1-Jan-2001, STOP=2-Feb-2002,RECINT=all(0); DELETE SCANBTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTS DELETE SCANBTS UNSUCCESSFUL_WRONG_GRANULARITY With MEASLIST=allMeas(0) or MEASLIST=measlist(MBTCHCHT) GRANP must be at least MINUTE_15. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. UNSUCCESSFUL_LIST_OF_OBJECT The OBJLIST contains more times the same object. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. DELETE SCANBTS: NAME=SCANBTS:scann; 978 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 2. Command Description: The command deletes a scanner instance which has been previously created. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete SCANBTS:NAME=SCANBTS:0; GET SCANBTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTS GET SCANBTS Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a SCANBTS, the relative object instance must be in LOCKED state. GET SCANBTS: NAME=SCANBTS:scann [,REQATTL=MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, LSUPDTIME, LSLOTIME, LSULOTIME]; A30808-X3247-L230-3-7619 979 Commands Base Station Controller CML:BSC The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTS:NAME=SCANBTS:0,REQATTL=MEASLST&OBJLST&GRANP& REPMETHD&START&STOP&RECINT&LSUPDTIME&LSLOTIME&LSULOTIME; GET SCANBTS BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTS GET SCANBTS BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "scann" can be found in Appendix A. GET ACK: NAME: SCANBTS MEASLIST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANBTS BASICS: NAME=SCANBTS:scann; 980 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTS BASICS:NAME=SCANBTS:0; GET SCANBTS STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTS GET SCANBTS STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SCANBTS object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "scann" can be found in Appendix A. GET SCANBTS BASICS ACK: NAME: SCANBTS MEASLIST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET SCANBTS BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANBTS STAT: NAME=SCANBTS:scann; A30808-X3247-L230-3-7619 981 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTS STAT:NAME=SCANBTS:0; LOCK SCANBTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTS LOCK SCANBTS Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). GET SCANBTS STAT ACK: GET SCANBTS STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK SCANBTS: NAME=SCANBTS:scann; LOCK SCANBTS ACK: LOCK SCANBTS NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 982 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Lock SCANBTS:NAME=SCANBTS:0; REMOVE SCANBTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTS REMOVE SCANBTS Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Remove SCANBTS:NAME=SCANBTS:0,MEASOBJLST=measList(NRFLSDCC); REMOVE SCANBTS: NAME=SCANBTS:scann, MEASOBJLST=; REMOVE ACK: SUCCESSFUL REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. WRONG_LIST_OF_MEASURE Measure not present or only one measure within database. UNSUCCESSFUL_LIST_OF_OBJECT The object list must contain at least one object under measure. Object under measure must be present within database or scanner in selfadapting mode. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. A30808-X3247-L230-3-7619 983 Commands Base Station Controller CML:BSC SET SCANBTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTS SET SCANBTS Applicability: Phase 2. Visibility level 2. Command Description: This command sets the configuration of instance of the SCANBTS object. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: SET SCANBTS: NAME=SCANBTS:scann [,MEASLST=] [,OBJLST=] [,GRANP=] [,START=] [,STOP=] [,RECINT=]; SET ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANBTS: name = SCANBTS:<istn> commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_WRONG_GRANULARITY With MEASLIST=allMeas(0) or MEASLIST=measlist(MBTCHCHT) GRANP must be at least MINUTE_15. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. UNSUCCESSFUL_LIST_OF_OBJECT The OBJLIST contains more times the same object. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED 984 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution Set SCANBTS:NAME=SCANBTS:0,MEASLST=allMeas(0),OBJLST=selfAdapting(0), GRANP=MINUTES_15,START=1-Jan-2001,STOP=1-Jan-2002,RECINT=all(0); UNLOCK SCANBTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTS UNLOCK SCANBTS Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scann" can be found in Appendix A. System Responses: The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. UNLOCK SCANBTS: NAME=SCANBTS:scann; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE A30808-X3247-L230-3-7619 985 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Unlock SCANBTS:NAME=SCANBTS:0; The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 986 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SCANBTSABISTD The SCANBTSABISTD (Scanner BTSABISTD) represents a scanning function on a BSC managed object, and is able to report periodically the collected measurements. ADD SCANBTSABISTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSABISTD ADD SCANBT- SABISTD Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add objests to the original configuration of a scanner previously created by the user. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. ADD SCANBTSABISTD: NAME=SCANBTSABISTD:scantdn, MEASOBJLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object have been already configured in an other scanner. WRONG_LIST_OF_MEASURE Some measures are already present inside the scanner measures list. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. Scanner is in selfAdapting mode or exceeded max number of objects. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. A30808-X3247-L230-3-7619 987 Commands Base Station Controller CML:BSC Example of Command Execution Add SCANBTSABISTD:NAME=SCANBTSABISTD:0,MEASOBJLST=5-0&6-0&7-0&8- 0&9-0&10-0&11-0; CREATE SCANBTSABISTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC SCANBTSABISTD CREATE SCANBTSABISTD Applicability: Phase 2. Visibility level 1. Command Description: This command creates the configuration of instance of the SCANBTSABISTD object. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: CREATE SCANBTSABISTD: NAME=SCANBTSABISTD:scantdn, OBJLST= [,GRANP=] [,START=] [,STOP=] ,RECINT= [,TAREDLVR]=; CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANBTSABISTD:scantdn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCANBTSABISTD: name = SCANBTSABISTD:scantdn commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the managed object must not be already created. UNSUCCESSFUL_INVALID_STATUS The measurements have to be applied to already equipped object instances; after the creation of the object the ADMINISTRATIVE state is UNLOCKED 988 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: When a Restart of BSC is done, the Perfomance Measurements Data collected in the last granularity are not signicant. Example of Command Execution Create SCANBTSABISTD:NAME=SCANBTSABISTD:0,OBJLST=ObjectList(0-0&1- 0&2-0&3-0),GRANP=MINUTES_30,START=1-Jan-2003,STOP=1-Mar- 2003,RECINT=daily(0-0-5-59&12-0-17-59),TAREDLVR=0&1&3&5&7&10&13; DELETE SCANBTSABISTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC SCANBTSABISTD DELETE SCANBTSABISTD Applicability: Phase 2. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object has been already configured in another scanner. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. UNSUCCESSFUL_INVALID_DATE The start date or the stop date are incorrect. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. UNSUCCESSFUL_WRONG_TA_RANGE For TAREDLVR the following rules must be fulfilled: Inputvalue1 < Inputvalue2 < Inputvalue3 < Inputvalue4 < Inputvalue5 < Inputvalue6 < Inputvalue7. DELETE SCANBTSABISTD NAME=SCANBTSABISTD:scantdn; A30808-X3247-L230-3-7619 989 Commands Base Station Controller CML:BSC Visibility level 1. Command Description: This command deletes a scanner instance which has been previously created. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete SCANBTSABISTD:NAME=SCANBTSABISTD:0; GET SCANBTSABISTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC SCANBTSABISTD GET SCANBTSABISTD Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameter values of an existing scanner instance. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: DELETE ACK: SUCCESSFUL DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. GET SCANBTSABISTD NAME=SCANBTSABISTD:scantdn [,REQATTL= MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, TAREDLVR, LSUPDTIME, LSLOTIME, LSULOTIME]; GET ACK: NAME: SCANBTSABISTD MEASLST: measureList 990 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get SCANBTSABISTD:NAME=SCANBTSABISTD:0,REQATTL=MEASLST& OBJLST&GRANP&REPMETHD&START&STOP&RECINT&TAREDLVR& LSUPDTIME&LSLOTIME&LSULOTIME; GET SCANBTSABISTD BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC SCANBTSABISTD GET SCANBTSABISTD Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve all the parameter values of the BASICS group of an existing scanner instance. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval TAREDLVR: taRedLevelRange LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. GET SCANBTSABISTD NAME=SCANBTSABISTD:scantdn; GET ACK: NAME: SCANBTSABISTD MEASLST: measureList A30808-X3247-L230-3-7619 991 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get SCANBTSABISTD BASICS:NAME=SCANBTSABISTD:0; GET SCANBTSABISTD STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSABISTD GET SCANBTSABISTD STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SCANBTSABISTD object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "scantdn" can be found in Appendix A. OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval TAREDLVR: taRedLevelRange LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. GET SCANBTSABISTD STAT: NAME=SCANBTSABISTD:scantdn; 992 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSABISTD STAT:NAME=SCANBTSABISTD:0; LOCK SCANBTSABISTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSABISTD LOCK SCAN- BTSABISTD Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). GET SCANBTSABISTD STAT ACK: GET SCANBTSABISTD STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. LOCK SCANBTSABISTD: NAME=SCANBTSABISTD:scantdn; LOCK SCANBTSABISTD ACK: LOCK SCANBTSABISTD NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. A30808-X3247-L230-3-7619 993 Commands Base Station Controller CML:BSC Example of Command Execution Lock SCANBTSABISTD:NAME=SCANBTSMTD:0; REMOVE SCANBTSABISTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSABISTD REMOVE SCANBTSABISTD Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove objects from the original configuration of a scanner previously created by the user. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Remove SCANBTSABISTD:NAME=SCANBTSABISTD:0,MEASOBJLST=objList(1&2) REMOVE SCANBTSABISTD: NAME=SCANBTSABISTD:scantdn, MEASOBJLST=; REMOVE ACK: Successful REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. UNSUCCESSFUL_LIST_OF_OBJECT The object list must contain almost one object under measure. Object under measure must be present within database or scanner in selfadapting mode. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. 994 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SET SCANBTSABISTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSABISTD SET SCANBT- SABISTD Applicability: Phase 2. Visibility level 2. Command Description: This command is used to change the parameter values, previously defined by the user by means of a create command, for the instance scantdn of the SCANBTSABISTD object. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: SET SCANBTSABISTD: NAME=SCANBTSABISTD:scantdn [,OBJLST=] [,GRANP=] [,START=] [,STOP=] [,RECINT=] [,TAREDLVR=]; SET ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANBTSABISTD: name = SCANBTSABISTD:<istn> commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object has been already configured in another scanner. UNSUCCESSFUL_WRONG_LIST_OF_MEASURE The measures list cannot be empty. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. UNSUCCESSFUL_INVALID_DATE The start date or the stop date are incorrect. UNSUCCESSFUL_TIMEFRAME_INCORRECT A30808-X3247-L230-3-7619 995 Commands Base Station Controller CML:BSC Application Guidelines: When a Restart of BSC is done, the Perfomance Measurements Data collected in the last granularity are not signicant. Regarding Abis measurements, PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, no report is generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within START_DATE and STOP_DATE attributes values. Example of Command Execution Set SCANBTSABISTD:NAME=SCANBTSABISTD:0,OBJLST=ObjectList(0-0&1-0&2- 0),GRANP=MINUTES_30,START=1-Jan-2003,STOP=1-Mar-2003,RECINT=daily(2-0- 6-0&11-0-18-30),TAREDLVR=5&8&11&13&17&22&28; UNLOCK SCANBTSABISTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSABISTD UNLOCK SCANBTSABISTD Applicability: Phase 2. Visibility level 1. The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. UNSUCCESSFUL_WRONG_TA_RANGE For TAREDLVR the following rules must be fulfilled: Inputvalue1 < Inputvalue2 < Inputvalue3 < Inputvalue4 < Inputvalue5 < Inputvalue6 < Inputvalue7. UNLOCK SCANBTSABISTD: NAME=SCANBTSABISTD:scantdn; 996 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock SCANBTSABISTD:NAME=SCANBTSABISTD:0; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. A30808-X3247-L230-3-7619 997 Commands Base Station Controller CML:BSC SCANBTSE The SCANBTSE (Scanner BTSE) represents a scanning function on a specific set of BTS managed objects, and is able to report periodically the collected measurements; the raw data are collected at BTSE and forwarded to BSC. ADD SCANBTSE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSE ADD SCANBTSE Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. ADD SCANBTSE: NAME=SCANBTSE:scann ,MEASOBJLST=; ADD ACK: Successful. ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object have been already configured in another scanner. WRONG_LIST_OF_MEASURE Trying to add a measure already present inside scanner measures list. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. Scanner is in selfAdapting mode or exceeded max number of objects. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. 998 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Add SCANBTSE:NAME=SCANBTSE:0,MEASOBJLST=1-1&0-3; CREATE SCANBTSE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSE CREATE SCANBTSE Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the SCANBTS object. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: CREATE SCANBTSE: NAME=SCANBTSE:scann ,MEASLST= ,OBJLST= [,GRANP=] [,START=] [,STOP=] ,RECINT=; CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANBTSE:istn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCANBTSE: name = SCANBTSE:istn commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: UNSUCCESSFUL_VAR_OUT_OF_RANGE Max number of scanner exceeded. UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. A30808-X3247-L230-3-7619 999 Commands Base Station Controller CML:BSC Application Guidelines: Regarding Abis measurements, PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, no report is generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within START_DATE and STOP_DATE attributes values. Example of Command Execution Create SCANBTSE:NAME=SCANBTSE:0,MEASLST=measList(NINVRACH), OBJLST=selfAdapting(0),GRANP=MINUTES_30,START=1-Jan-2001, STOP=31-Dec-2001,RECINT=weekly((suPeriod((5-0-7-59))-moNoSched(0)- tuNoSched(0)-wePeriod((3-0-9-59))-thNoSched(0)--saNoSched(0))); DELETE SCANBTSE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSE DELETE SCANBTSE Applicability: Phase 2. Visibility level 2. Command Description: The command deletes a scanner instance which has been previously created. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. UNSUCCESSFUL_LIST_OF_OBJECT The OBJLIST contains the same object more times. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. DELETE SCANBTSE: NAME=SCANBTSE:scann; 1000 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete SCANBTSE:NAME=SCANBTSE:0; GET SCANBTSE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSE GET SCANBTSE Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. The validity range of the object address "scann" can be found in Appendix A. System Responses: DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a SCANBTSE, the relative object instance must be in LOCKED state. GET SCANBTSE: NAME=SCANBTSE:scann [,REQATTL=MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, LSUPDTIME, LSLOTIME, LSULOTIME]; GET ACK: NAME: SCANBTSE MEASLIST: measureList A30808-X3247-L230-3-7619 1001 Commands Base Station Controller CML:BSC Application Guidelines: None Example of Command Execution Get SCANBTSE:NAME=SCANBTSE:0,REQATTL=MEASLST&OBJLST&GRANP& REPMETHD&START&STOP&RECINT&LSUPDTIME&LSLOTIME&LSULOTIME; GET SCANBTSE BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSE GET SCANBTSE BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "scann" can be found in Appendix A. System Responses: OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANBTSE BASICS: NAME=SCANBTSE:scann; GET SCANBTSE BASICS ACK: NAME: SCANBTSE MEASLIST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod 1002 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get SCANBTSE BASICS:NAME=SCANBTSE:0; GET SCANBTSE STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSE GET SCANBTSE STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SCANBTSE object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "scann" can be found in Appendix A. System Responses: START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET SCANBTSE BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANBTSE STAT: NAME=SCANBTSE:scann; GET SCANBTSE STAT ACK: GET SCANBTSE STAT NACK: A30808-X3247-L230-3-7619 1003 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get SCANBTSE STAT:NAME=SCANBTSE:0; LOCK SCANBTSE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSE LOCK SCANBTSE Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock SCANBTSE:NAME=SCANBTSE:0; NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK SCANBTSE: NAME=SCANBTSE:scann; LOCK SCANBTSE ACK: LOCK SCANBTSE NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1004 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller REMOVE SCANBTSE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSE REMOVE SCANBTSE Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Remove SCANBTSE:NAME=SCANBTSE:0,MEASOBJLST=0-0; REMOVE SCANBTSE: NAME=SCANBTSE:scann ,MEASOBJLST=; REMOVE ACK: Successful REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. WRONG_LIST_OF_MEASURE Measure not present or only one measure within database. UNSUCCESSFUL_LIST_OF_OBJECT The object list must contain at least one object under measure. Object under measure must be present within database or scanner in selfadapting mode. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. A30808-X3247-L230-3-7619 1005 Commands Base Station Controller CML:BSC SET SCANBTSE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSE SET SCANBTSE Applicability: Phase 2. Visibility level 2. Command Description: This command sets the configuration of instance of the SCANBTSE object. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: SET SCANBTSE: NAME=SCANBTSE:scann [,MEASLST=] [,OBJLST=] [,GRANP=] [,START=] [,STOP=] [,RECINT=]; SET ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANBTSE: name = SCANBTSE:<istn> commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. UNSUCCESSFUL_LIST_OF_OBJECT The OBJLIST contains the same object more times. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION 1006 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: Regarding Abis measurements, PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, no report is generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within START_DATE and STOP_DATE attributes values. Example of Command Execution Set SCANBTSE:NAME=SCANBTSE:0,MEASLST=measList(AMRCHDIS), OBJLST=selfAdapting(0),GRANP=MINUTES_15,START=22-Mar-2001, STOP=31-Jun-2002,RECINT=all(0); UNLOCK SCANBTSE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSE UNLOCK SCANBTSE Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scann" can be found in Appendix A. System Responses: Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. UNLOCK SCANBTSE: NAME=SCANBTSE:scann; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1007 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Unlock SCANBTSE:NAME=SCANBTSE:0; 1008 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SCANBTSIHO The SCANBTSIHO(Scanner BTS Incoming HandOver) represents a scanning function on a specific set of origination/destination cells pairs involved in incoming handovers, and is able to report periodically the collected measurements; raw data are collected at BSC. ADD SCANBTSIHO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSIHO ADD SCANBTSIHO Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: ADD SCANBTSIHO: NAME=SCANBTSIHO:scann, MEASOBJLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object have been already configured in an other scanner. WRONG_LIST_OF_MEASURE Trying to add a measure already present inside scanner measures list. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same target BTS more times. On a single adjacent list the same BTS object is present more times. It is not possible to add an adjacents list when the adjacents list is in selfAdapting mode. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. A30808-X3247-L230-3-7619 1009 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Add SCANBTSIHO:NAME=SCANBTSIHO:0,MEASOBJLST=(0-0)-selfAdapting(0); CREATE SCANBTSIHO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSIHO CREATE SCANBTSIHO Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the SCANNER of BTS Incoming Handover class. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: CREATE SCANBTSIHO: NAME=SCANBTSIHO:scann ,MEASLST= [,GRANP=] [,START=] [,STOP=] ,RECINT= ,OBJLST=; CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANBTSIHO:istn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCANBTSIHO: name = SCANBTSIHO:istn commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: UNSUCCESSFUL_VAR_OUT_OF_RANGE Max number of scanner exceeded. 1010 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution Create SCANBTSIHO:NAME=SCANBTSIHO:0,MEASLST=allMeas(0), OBJLST=(0-0)-selfAdapting(0)&(0-1)-selfAdapting(0),GRANP=MINUTES_60, START=1-Jan-2001,STOP=31-Dec-2002,RECINT=all(0); DELETE SCANBTSIHO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSIHO DELETE SCANBTSIHO UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same target BTS more times. On a single adjacent list the same BTS object is present more times. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of gran- ularity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. DELETE SCANBTSIHO: NAME=SCANBTSIHO:scann; A30808-X3247-L230-3-7619 1011 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 2. Command Description: The command deletes a scanner instance which has been previously created. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete SCANBTSIHO:NAME=SCANBTSIHO:0; GET SCANBTSIHO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSIHOGET SCANBTSIHO Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. GET SCANBTSIHO: NAME=SCANBTSIHO:scann [,REQATTL=MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, LSUPDTIME, LSLOTIME, LSULOTIME]; 1012 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSIHO:NAME=SCANBTSIHO:0,REQATTL=MEASLST&OBJLST& GRANP&REPMETHD&START&STOP&RECINT&LSUPDTIME&LSLOTIME& LSULOTIME; GET SCANBTSIHO BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSIHO GET SCANBTSIHO BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "scann" can be found in Appendix A. GET ACK: NAME: SCANBTSIHO MEASLIST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANBTSIHO BASICS: NAME=SCANBTSIHO:scann; A30808-X3247-L230-3-7619 1013 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSIHO BASICS:NAME=SCANBTSIHO:0; GET SCANBTSIHO STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSIHO GET SCANBTSIHO STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SCANBTSIHO object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). GET SCANBTSIHO BASICS ACK: NAME: SCANBTSIHO MEASLIST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET SCANBTSIHO BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANBTSIHO STAT: NAME=SCANBTSIHO:scann; 1014 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSIHO STAT:NAME=SCANBTSIHO:0; LOCK SCANBTSIHO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSIHO LOCK SCANBTSIHO Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). GET SCANBTSIHO STAT ACK: GET SCANBTSIHO STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK SCANBTSIHO: NAME=SCANBTSIHO:scann; LOCK SCANBTSIHO ACK: LOCK SCANBTSIHO NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1015 Commands Base Station Controller CML:BSC 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock SCANBTSIHO:NAME=SCANBTSIHO:0; REMOVE SCANBTSIHO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSIHO REMOVE SCANBTSIHO Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. REMOVE SCANBTSIHO: NAME=SCANBTSIHO:scann, MEASOBJLST=; REMOVE ACK: Successful REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. WRONG_LIST_OF_MEASURE Measure not present or only one measure within database. UNSUCCESSFUL_LIST_OF_OBJECT The object list must contain at least one object under measure. Object under measure must be present within database or scanner in selfadapting mode. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. 1016 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Remove SCANBTSIHO:NAME=SCANBTSIHO:0, MEASOBJLST=(0-0)-selfAdapting(0); SET SCANBTSIHO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSIHOSET SCANBTSIHO Applicability: Phase 2. Visibility level 2. Command Description: This command sets the configuration of instance of the SCANNER of BTS Incoming Handover class. The parameter specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: SET SCANBTSIHO: NAME=SCANBTSIHO:scann [,MEASLST=] [,OBJLST=] [,GRANP=] [,START=] [,STOP=] [,RECINT=]; SET ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANBTSIHO: name = SCANBTSIHO:<istn> commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same target BTS more times. On a single adjacent list the same BTS object is present more times. UNSUCCESSFUL_TIMEFRAME_INCORRECT A30808-X3247-L230-3-7619 1017 Commands Base Station Controller CML:BSC Application Guidelines: 1. When a Restart of BSC is done, the Performance Measurements Data collected in the last granularity are not signicant. 2. The measurements have to be applied to already equipped object instances. Example of Command Execution Set SCANBTSIHO:NAME=SCANBTSIHO:0,MEASLST=measList(AININIRH), OBJLST=(0-0)-selfAdapting(0),GRANP=MINUTES_60,START=22-Dec-2001, STOP=5-Apr-2003,RECINT=all(0); UNLOCK SCANBTSIHO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSIHO UNLOCK SCANBTSIHO Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scann" can be found in Appendix A. The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNLOCK SCANBTSIHO: NAME=SCANBTSIHO:scann; 1018 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Unlock SCANBTSIHO:NAME=SCANBTSIHO:0; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1019 Commands Base Station Controller CML:BSC SCANBTSM The SCANBTSM (Scanner BTSM) represents a scanning function on a specific set of BTSMmanaged objects, and is able to report periodically the collected measurements; the raw data are collected at BTSE and forwarded to BSC. ADD SCANBTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSM ADD SCANBTSM Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. ADD SCANBTSM: NAME=SCANBTSM:scann, MEASOBJLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. Scanner is in selfAdapting mode or exceeded max number of objects. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object have been already configured in an other scanner. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. WRONG_LIST_OF_MEASURE MEASLIST contains other measure besides BTSEPRLD MEASLIST contains other measure besides IFRMABIS 1020 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Add SCANBTSM:NAME=SCANBTSM:0,MEASOBJLST=15&16; CREATE SCANBTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSM CREATE SCANBTSM Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the SCANBTSM object. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: CREATE SCANBTSM: NAME=SCANBTSM:scann ,MEASLST= ,OBJLST= [,GRANP=] [,START=] [,STOP=] ,RECINT=; CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANBTSM:istn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCANBTSM: name = SCANBTSM:istn commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: UNSUCCESSFUL_VAR_OUT_OF_RANGE Max number of scanner exceeded. UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_MEAS_ALREADY_PRESENT A30808-X3247-L230-3-7619 1021 Commands Base Station Controller CML:BSC Application Guidelines: Regarding Abis measurements, PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, no report is generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within START_DATE and STOP_DATE attributes values. Example of Command Execution Create SCANBTSM:NAME=SCANBTSM:0,MEASLST=IFRMABIS, OBJLST=selfAdapting(0),GRANP=MINUTES_15,START=1-Jan-2001,STOP=1-Dec- 2001, RECINT=all(0); DELETE SCANBTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSMDELETE SCANBTSM Applicability: Phase 2. Visibility level 2. The same measure on the same object has been already configured in an other scanner. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. MEASLIST contains other measure besides BTSEPRLD MEASLIST contains other measure besides IFRMABIS UNSUCCESSFUL_LIST_OF_OBJECT The OBJLIST contains the same object more times. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. DELETE SCANBTSM: NAME=SCANBTSM:scann; 1022 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: The command deletes a scanner instance which has been previously created. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete SCANBTSM:NAME=SCANBTSM:0; GET SCANBTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSM GET SCANBTSM Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. The validity range of the object address "scann" can be found in Appendix A. DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a SCANBTSM, the relative object instance must be in LOCKED state. GET SCANBTSM: NAME=SCANBTSM:scann [,REQATTL=MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, LSUPDTIME, LSLOTIME, LSULOTIME]; A30808-X3247-L230-3-7619 1023 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSM:NAME=SCANBTSM:0,REQATTL=MEASLST&OBJLST&GRANP& REPMETHD&START&STOP&RECINT&LSUPDTIME&LSLOTIME&LSULOTIME; GET SCANBTSM BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSM GET SCANBTSM BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "scann" can be found in Appendix A. GET ACK: NAME: SCANBTSM MEASLIST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANBTSM BASICS: NAME=SCANBTSM:scann; 1024 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSM BASICS:NAME=SCANBTSM:0; GET SCANBTSM STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSM GET SCANBTSM STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SCANBTSM object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). GET SCANBTSM BASICS ACK: NAME: SCANBTSM MEASLIST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET SCANBTSM BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANBTSM STAT: NAME=SCANBTSM:scann; A30808-X3247-L230-3-7619 1025 Commands Base Station Controller CML:BSC The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSM STAT:NAME=SCANBTSM:0; LOCK SCANBTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSM LOCK SCANBTSM Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). GET SCANBTSM STAT ACK: GET SCANBTSM STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK SCANBTSM: NAME=SCANBTSM:scann; LOCK SCANBTSM ACK: LOCK SCANBTSM NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1026 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Lock SCANBTSM:NAME=SCANBTSM:0; A30808-X3247-L230-3-7619 1027 Commands Base Station Controller CML:BSC REMOVE SCANBTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSM REMOVE SCANBTSM Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Remove SCANBTSM:NAME=SCANBTSM:0,MEASOBJLST=1&1; REMOVE SCANBTSM: NAME=SCANBTSM:scann, MEASOBJLST=; REMOVE ACK: Successful REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_LIST_OF_OBJECT The object list must contain almost one object under measure. Object under measure must be present within database or scanner in selfadapting mode. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. 1028 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SET SCANBTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSM SET SCANBTSM Applicability: Phase 2. Visibility level 2. Command Description: This command sets the configuration of instance of the SCANBTSM object. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: SET SCANBTSM: NAME=SCANBTSM:scann [,MEASLST=] [,OBJLST=] [,GRANP=] [,START=] [,STOP=] [,RECINT=]; SET ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANBTSM: name = SCANBTSM:<istn> commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. MEASLIST contains other measure besides BTSEPRLD MEASLIST contains other measure besides IFRMABIS UNSUCCESSFUL_LIST_OF_OBJECT The OBJLIST contains the same object more times. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. A30808-X3247-L230-3-7619 1029 Commands Base Station Controller CML:BSC Application Guidelines: Regarding Abis measurements, PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, no report is generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within START_DATE and STOP_DATE attributes values. Example of Command Execution Set SCANBTSM:NAME=SCANBTSM:0,MEASLST=IFRMABIS, OBJLST=selfAdapting(0),GRANP=MINUTES_60,START=1-Jan-2001,STOP=5-Dec- 2001, RECINT=all(0); UNLOCK SCANBTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSM UNLOCK SCANBTSM Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scann" can be found in Appendix A. System Responses: UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. UNLOCK SCANBTSM: NAME=SCANBTSM:scann; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE 1030 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Unlock SCANBTSM:NAME=SCANBTSM:0; The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1031 Commands Base Station Controller CML:BSC SCANBTSMTD The SCANBTSMTD (Scanner BTSMTD) represents a scanning function on a specific set of BTSMTD managed objects, and is able to report periodically the collected measurements; the raw data are collected at BTSE and forwarded to BSC. ADD SCANBTSMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSMTD ADD SCAN- BTSMTD Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add measures and objects to the original configuration of a scanner previously created by the user. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. ADD SCANBTSMTD: NAME=SCANBTSMTD:scantdn, MEASOBJLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object has been already configured in another scanner. UNSUCCESSFUL_LIST_OF_OBJECT Some measures are already present within scanner. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. Scanner is in selfAdapting mode or exceeded max number of objects. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. 1032 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Add SCANBTSMTD:NAME=SCANBTSMTD:0,MEASOBJLST=objlist(15&16); CREATE SCANBTSMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSMTD CREATE SCANBTSMTD Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the SCANBTSMTD object. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: CREATE SCANBTSMTD: NAME=SCANBTSMTD:scantdn, MEASLST= ,OBJLST= [,GRANP=] [,START=] [,STOP=] ,RECINT= CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANBTSMTD:istn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCANBTSMTD: name = SCANBTSMTD:istn commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the managed object must not be already created. UNSUCCESSFUL_INVALID_STATUS The measurements have to be applied to already equipped object instances; after the creation of the object the ADMINISTRATIVE state is UNLOCKED UNSUCCESSFUL_MEAS_ALREADY_PRESENT A30808-X3247-L230-3-7619 1033 Commands Base Station Controller CML:BSC Application Guidelines: When a Restart of BSC is done, the Perfomance Measurements Data collected in the last granularity are not signicant. Regarding Abis measurements, PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, no report is generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within START_DATE and STOP_DATE attributes values. Example of Command Execution Create SCANBTSMTD:NAME=SCANBTSMTD:0,MEASLST=measList(TDBTSEPR LD),OBJLST=selfAdapting(0),GRANP=MINUTES_15,START=1-Jan-2003,STOP=1- Mar-2003,RECINT=all(0); The same measure and the same object has been already configured in another scanner. UNSUCCESSFUL_WRONG_LIST_OF_MEASURE The measures list cannot be empty. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. UNSUCCESSFUL_INVALID_DATE The start date or the stop date are incorrect. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_VAR_OUT_OF_RANGE Max number of scanner exceeded. 1034 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DELETE SCANBTSMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSMTD DELETE SCAN- BTSMTD Applicability: Phase 2. Visibility level 2. Command Description: The command deletes a scanner instance which has been previously created. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete SCANBTSMTD:NAME=SCANBTSMTD:0; DELETE SCANBTSMTD: NAME=SCANBTSMTD:scantdn; DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. A30808-X3247-L230-3-7619 1035 Commands Base Station Controller CML:BSC GETSCANBTSMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSMTD GET SCAN- BTSMTD Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSMTD:NAME=SCANBTSMTD:0,REQATTL=MEASLST&OBJLST& GRANP& REPMETHD&START&STOP&RECINT&LSUPDTIME&LSLOTIME& LSULOTIME; GET SCANBTSMTD: NAME=SCANBTSMTD:scantdn [,REQATTL=MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, LSUPDTIME, LSLOTIME, LSULOTIME]; GET ACK: NAME: SCANBTSMTD MEASLST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. 1036 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET SCANBTSMTD BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSMTD GET SCANBTSMTD BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSMTD BASICS:NAME=SCANBTSMTD:0; GET SCANBTSMTD BASICS: NAME=SCANBTSMTD:scantdn; GET SCANBTSMTD BASICS ACK: NAME: SCANBTSMTD MEASLST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET SCANBTSMTD BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. A30808-X3247-L230-3-7619 1037 Commands Base Station Controller CML:BSC GET SCANBTSMTD STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSMTD GET SCANBTSMTD STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SCANBTSMTD object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSMTD STAT:NAME=SCANBTSMTD:0; LOCK SCANBTSMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSMTD LOCK SCAN- BTSMTD GET SCANBTSMTD STAT: NAME=SCANBTSMTD:scantdn; GET SCANBTSMTD STAT ACK: GET SCANBTSMTD STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. LOCK SCANBTSMTD: NAME=SCANBTSMTD:scantdn; 1038 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock SCANBTSMTD:NAME=SCANBTSMTD:0; REMOVE SCANBTSMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSMTD REMOVE SCANBTSMTD Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove measures and objects from the original configuration of a scanner previously created by the user. The validity range of the object address "scantdn" can be found in Appendix A. LOCK SCANBTSMTD ACK: LOCK SCANBTSMTD NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. REMOVE SCANBTSMTD: NAME=SCANBTSMTD:scantdn, MEASOBJLST=; A30808-X3247-L230-3-7619 1039 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Remove SCANBTSMTD:NAME=SCANBTSMTD:0,MEASOBJLST=objList(1&2) REMOVE ACK: Successful REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. UNSUCCESSFUL_LIST_OF_OBJECT The object list must contain almost one object under measure. Object under measure must be present within database or scanner in selfadapting mode. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. 1040 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SET SCANBTSMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSMTD SET SCAN- BTSMTD Applicability: Phase 2. Visibility level 2. Command Description: This command is used to change the parameter values, previously defined by the user by means of a create command, for the instance scantdn of the SCANBTSMTDobject. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: SET SCANBTSMTD: NAME=SCANBTSMTD:scantdn [,MEASLST=] [,OBJLST=] [,GRANP=] [,START=] [,STOP=] [,RECINT=]; SET ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANBTSMTD: name = SCANBTSMTD:<istn> commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object has been already configured in another scanner. UNSUCCESSFUL_WRONG_LIST_OF_MEASURE The measures list cannot be empty. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. UNSUCCESSFUL_INVALID_DATE The start date or the stop date are incorrect. UNSUCCESSFUL_TIMEFRAME_INCORRECT A30808-X3247-L230-3-7619 1041 Commands Base Station Controller CML:BSC Application Guidelines: When a Restart of BSC is done, the Perfomance Measurements Data collected in the last granularity are not signicant. Regarding Abis measurements, PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, no report is generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within START_DATE and STOP_DATE attributes values. Example of Command Execution Set SCANBTSMTD:NAME=SCANBTSMTD:0,MEASLST=measList(TDBTSEPR LD),OBJLST=selfAdapting(0),GRANP=MINUTES_15,START=1-Jan-2003,STOP=3- Mar-2003,RECINT=all(0); UNLOCK SCANBTSMTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSMTD UNLOCK SCANBTSMTD Applicability: Phase 2. Visibility level 1. The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNLOCK SCANBTSMTD: NAME=SCANBTSMTD:scantdn; 1042 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock SCANBTSMTD:NAME=SCANBTSMTD:0; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. A30808-X3247-L230-3-7619 1043 Commands Base Station Controller CML:BSC SCANBTSOHOI The SCANBTSOHOI (Scanner BTS Outgoing HandOver to Internal cells) represents a scanning function on a specific set of origination/internal-destination cells pairs involved in outgoing handovers, and is able to report periodically the collected measurements; the raw data are collected at BSC. ADD SCANBTSOHOI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOI ADD SCANBTSOHOI Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: ADD SCANBTSOHOI: NAME=SCANBTSOHOI:scann, MEASOBJLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object have been already configured in an other scanner. WRONG_LIST_OF_MEASURE Trying to add a measure already present inside scanner measures list. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same target BTS more times. On a single adjacent list the same ADJC object is present more times. It is not possible to add an adjacents list when the adjacents list is in selfAdapting mode. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. 1044 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Add SCANBTSOHOI:NAME=SCANBTSOHOI:0,MEASOBJLST=measList(SOUINIRH | AOUINIRH); CREATE SCANBTSOHOI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOI CREATE SCANBTSOHOI Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the scanner providing measurement related to BTS outgoing handovers to internal cells. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: CREATE SCANBTSOHOI: NAME=SCANBTSOHOI:scann ,MEASLST=, OBJLST= [,GRANP=] [,START=] [,STOP=], RECINT=; CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANBTSOHOI:istn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCANBTSOHOI: name = SCANBTSOHOI:istn commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: A30808-X3247-L230-3-7619 1045 Commands Base Station Controller CML:BSC Application Guidelines: PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution Create SCANBTSOHOI:NAME=SCANBTSOHOI:0,MEASLST=allMeas(0), OBJLST=(1-1)-selfAdapting(0),GRANP=MINUTES_30,START=1-Jan-2001, STOP=31-Dec-2001,RECINT=all(0); UNSUCCESSFUL_VAR_OUT_OF_RANGE Max number of scanner exceeded. UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same target BTS more times. On a single adjacent list the same ADJC object is present more times. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. 1046 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DELETE SCANBTSOHOI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOI DELETE SCANBTSOHOI Applicability: Phase 2. Visibility level 2. Command Description: The command deletes a scanner instance which has been previously created. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete SCANBTSOHOI:NAME=SCANBTSOHOI:0; DELETE SCANBTSOHOI: NAME=SCANBTSOHOI:scann; DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a SCANBTSHOI, the relative object instance must be in LOCKED state. A30808-X3247-L230-3-7619 1047 Commands Base Station Controller CML:BSC GET SCANBTSOHOI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOI GET SCANBTSOHOI Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSOHOI:NAME=SCANBTSOHOI:0,REQATTL=MEASLST&OBJLST& GRANP&REPMETHD&START&STOP&RECINT&LSUPDTIME&LSLOTIME& LSULOTIME; GET SCANBTSOHOI: NAME=SCANBTSOHOI:scann [,REQATTL= MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, LSUPDTIME, LSLOTIME, LSULOTIME]; GET ACK: NAME: SCANBTSOHOI MEASLIST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1048 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET SCANBTSOHOI BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOI GET SCANBTSOHOI BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSOHOI BASICS:NAME=SCANBTSOHOI:0; GET SCANBTSOHOI BASICS: NAME=SCANBTSOHOI:scann,; GET SCANBTSOHOI BASICS ACK: NAME: SCANBTSOHOI MEASLIST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET SCANBTSOHOI BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1049 Commands Base Station Controller CML:BSC GET SCANBTSOHOI STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOI GET SCANBTSOHOI STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SCANBTSOHOI object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSOHOI STAT:NAME=SCANBTSOHOI:0; LOCK SCANBTSOHOI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOI LOCK SCANBTSOHOI GET SCANBTSOHOI STAT: NAME=SCANBTSOHOI:scann; GET SCANBTSOHOI STAT ACK: GET SCANBTSOHOI STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK SCANBTSOHOI: NAME=SCANBTSOHOI:scann; 1050 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock SCANBTSOHOI:NAME=SCANBTSOHOI:0; REMOVE SCANBTSOHOI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOI REMOVE SCANBTSOHOI Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. LOCK SCANBTSOHOI ACK: LOCK SCANBTSOHOI NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. REMOVE SCANBTSOHOI: NAME=SCANBTSOHOI:scann, MEASOBJLST=; A30808-X3247-L230-3-7619 1051 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Remove SCANBTSOHOI:NAME=SCANBTSOHOI:0, MEASOBJLST=measList(AOUINIRH | UNINHOIE); SET SCANBTSOHOI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOI SET SCANBTSOHOI Applicability: Phase 2. Visibility level 2. Command Description: This command sets the configuration instance of the scanner providing measurement related to BTS outgoing handovers to internal cells. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. REMOVE ACK: Successful REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. WRONG_LIST_OF_MEASURE Measure not present or only one measure within database. UNSUCCESSFUL_LIST_OF_OBJECT The object list must contain at least one object under measure. Object under measure must be present within database or scanner in selfadapting mode. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. SET SCANBTSOHOI: NAME=SCANBTSOHOI:scann [,MEASLST=] [,OBJLST=] [,GRANP=] [,START=] [,STOP=] [,RECINT=]; 1052 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution: Set SCANBTSOHOI:NAME=SCANBTSOHOI:0,MEASLST=allMeas(0), OBJLST=(1-1)-selfAdapting(0),GRANP=MINUTES_30,START=1-Jan-2001, STOP=3-Mar-2002,RECINT=all(0); SET ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANBTSOHOI: name = SCANBTSOHOI:<istn> commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same target BTS more times. On a single adjacent list the same ADJC object is present more times. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. A30808-X3247-L230-3-7619 1053 Commands Base Station Controller CML:BSC UNLOCK SCANBTSOHOI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOI UNLOCK SCANBTSOHOI Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock SCANBTSOHOI:NAME=SCANBTSOHOI:0; UNLOCK SCANBTSOHOI: NAME=SCANBTSOHOI:scann; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1054 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SCANBTSOHON The SCANBTSOHON (Scanner BTS Outgoing HandOver to Neighbour cells) represents a scanning function on a specific set of origination/neighbour-destination cells pairs involved in outgoing handovers, and is able to report periodically the collected measurements; the raw data are collected at BSC. ADD SCANBTSOHON Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHON ADD SCANBTSOHON Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add measures to the original configuration of a scanner previ- ously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: ADD SCANBTSOHON: NAME=SCANBTSOHON:scann, MEASOBJLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object have been already config- ured in an other scanner. WRONG_LIST_OF_MEASURE Trying to add a measure already present inside scanner measures list. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same target BTS more times. On a single adjacent list the same TGTBTS object is present more times. A30808-X3247-L230-3-7619 1055 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Add SCANBTSOHON:NAME=SCANBTSOHON:0, MEASOBJLST=measList(SUINBHDO); CREATE SCANBTSOHON Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHON CREATE SCANBTSOHON Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the scanner providing measurement related to BTS outgoing handovers to neighbour cells. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: It is not possible to add an adjacents list when the adjacents list is in selfAdapting mode. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. CREATE SCANBTSOHON: NAME=SCANBTSOHON:scann ,MEASLST=, OBJLST= [,GRANP=] [,START=] [,STOP=], RECINT=; CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANBTSOHON:istn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCANBTSOHON: name = SCANBTSOHON:istn 1056 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution Create SCANBTSOHON:NAME=SCANBTSOHON:0,MEASLST=allMeas(0), OBJLST=(1-1)-selfAdapting(0)&(2-1)-selfAdapting(0)&(4-22)-selfAdapting(0), GRANP=MINUTES_60,START=1-Jan-2001,STOP=31-Dec-2001,RECINT=all(0); commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: UNSUCCESSFUL_VAR_OUT_OF_RANGE Max number of scanner exceeded. UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same target BTS more times. On a single adjacent list the same TGTBTS object is present more times. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. A30808-X3247-L230-3-7619 1057 Commands Base Station Controller CML:BSC DELETE SCANBTSOHON Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHON DELETE SCANBTSOHON Applicability: Phase 2. Visibility level 2. Command Description: The command deletes a scanner instance which has been previously created. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete SCANBTSOHON:NAME=SCANBTSOHON:0; DELETE SCANBTSOHON: NAME=SCANBTSOHON:scann; DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a SCANBTSOHON, the relative object instance must be in LOCKED state. 1058 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET SCANBTSOHON Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHON GET SCANBTSOHON Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSOHON:NAME=SCANBTSOHON:0,REQATTL=MEASLST&OBJLIST& GRANP& REPMETHD& START&STOP&RECINT&LSUPDTIME&LSLOTIME& LSULOTIME; GET SCANBTSOHON: NAME=SCANBTSOHON:scann [,REQATTL=MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, LSUPDTIME, LSLOTIME, LSULOTIME]; GET ACK: NAME: SCANBTSOHON MEASLIST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1059 Commands Base Station Controller CML:BSC GET SCANBTSOHON BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHON GET SCANBTSOHON BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSOHON BASICS:NAME=SCANBTSOHON:0; GET SCANBTSOHON BASICS: NAME=SCANBTSOHON:scann; GET SCANBTSOHON BASICS ACK: NAME: SCANBTSOHON MEASLIST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET SCANBTSOHON BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1060 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET SCANBTSOHON STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHON GET SCANBTSOHON STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SCANBTSOHON object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSOHON STAT:NAME=SCANBTSOHON:0; LOCK SCANBTSOHON Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHON LOCK SCANBTSOHON GET SCANBTSOHON STAT: NAME=SCANBTSOHON:scann; GET SCANBTSOHON STAT ACK: GET SCANBTSOHON STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK SCANBTSOHON: NAME=SCANBTSOHON:scann; A30808-X3247-L230-3-7619 1061 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock SCANBTSOHON:NAME=SCANBTSOHON:0; REMOVE SCANBTSOHON Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHON REMOVE SCANBTSOHON Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. LOCK SCANBTSOHON ACK: LOCK SCANBTSOHON NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. REMOVE SCANBTSOHON: NAME=SCANBTSOHON:scann, MEASOBJLST=; 1062 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Remove SCANBTSOHON:NAME=SCANBTSOHON:0, MEASOBJLST=measList(NRUNINHD); SET SCANBTSOHON Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHON SET SCANBTSOHON Applicability: Phase 2. Visibility level 2. Command Description: This command sets the configuration of instance of the scanner providing measurement related to BTS outgoing handovers to neighbour cells. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. REMOVE ACK: Successful REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. WRONG_LIST_OF_MEASURE Measure not present or only one measure within database. UNSUCCESSFUL_LIST_OF_OBJECT The object list must contain at least one object under measure. Object under measure must be present within database or scanner in selfadapting mode. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. SET SCANBTSOHON: NAME=SCANBTSOHON:scann [,MEASLST=] [,OBJLST=] [,GRANP=] [,START=] [,STOP=] [,RECINT=]; A30808-X3247-L230-3-7619 1063 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution Set SCANBTSOHON:NAME=SCANBTSOHON:0,MEASLST=measList(ATINBHDO | SUINBHDO | NRUNINHD),OBJLST=(1-1)-selfAdapting(0),GRANP=MINUTES_5, START=1-Feb-2001,STOP=2-Mar-2002,RECINT=all(0); SET ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANBTSOHON: name = SCANBTSOHON:<istn> commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same target BTS more times. On a single adjacent list the same TGTBTS object is present more times. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. 1064 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller UNLOCK SCANBTSOHON Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHON UNLOCK SCANBTSOHON Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock SCANBTSOHON:NAME=SCANBTSOHON:0; UNLOCK SCANBTSOHON: NAME=SCANBTSOHON:scann; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1065 Commands Base Station Controller CML:BSC SCANBTSOHOS The SCANBTSOHOS represents a scanning function on a specific set of origination/neighbour-destination cell pairs involved in outgoing handovers fromGSMto UMTS system, and is able to report periodically the collected measurements; the raw data are collected at BSC. ADD SCANBTSOHOS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOS ADD SCANBTSOHOS Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Add SCANBTSOHOS:NAME=SCANBTSOHOS:0, MEASOBJLST=measList(ATOISHDO); ADD SCANBTSOHOS: NAME=SCANBTSOHOS:scann, MEASOBJLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_LIST_OF_OBJECT The same object instance cannot be repeated in the objList list. WRONG_LIST_OF_MEASURE A measure cannot be duplicated. Measure not present. 1066 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller CREATE SCANBTSOHOS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOS CREATE SCANBTSOHOS Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the scanner providing measurement related to BTS outgoing handovers from GSM to UMTS system. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: CREATE SCANBTSOHOS: NAME=SCANBTSOHOS:scann ,MEASLST=, OBJLST= [,GRANP=] [,START=] [,STOP=], RECINT=; CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANBTSOHOS:istn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCANBTSOHOS: name = SCANBTSOHOS:istn commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. WRONG_LIST_OF_MEASURE The measures list cannot be empty. A measure cannot be duplicated. Measure not present or only one measure within database. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. A30808-X3247-L230-3-7619 1067 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Create SCANBTSOHOS:NAME=SCANBTSOHOS:0,MEASLST=allMeas(0), OBJLST=(1-1)-selfAdapting(0)&(2-1)-selfAdapting(0)&(4-22)-selfAdapting(0), GRANP=MINUTES_60,START=1-Jan-2001,STOP=31-Dec-2001,RECINT=all(0); DELETE SCANBTSOHOS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOS DELETE SCANBTSOHOS Applicability: Phase 2. Visibility level 2. Command Description: The command deletes a scanner instance which has been previously created. The validity range of the object address "scann" can be found in Appendix A. UNSUCCESSFUL_VAR_OUT_OF_RANGE The global number of equipped scanner objects must not exceed a fixed maximum number (90). UNSUCCESSFUL_LIST_OF_OBJECT The same object instance cannot be repeated in the OBJLST list. UNSUCCESSFUL_INVALID_DATE The start date or the stop date are incorrect. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). DELETE SCANBTSOHOS: NAME=SCANBTSOHOS:scann; 1068 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Delete SCANBTSOHOS:NAME=SCANBTSOHOS:0; GET SCANBTSOHOS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOS GET SCANBTSOHOS Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. The validity range of the object address "scann" can be found in Appendix A. System Responses: DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a SCANBTSOHOS, the relative object instance must be in LOCKED state. GET SCANBTSOHOS: NAME=SCANBTSOHOS:scann [,REQATTL=MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, LSUPDTIME, LSLOTIME, LSULOTIME]; GET ACK: NAME: SCANBTSOHON MEASLIST: measureList A30808-X3247-L230-3-7619 1069 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get SCANBTSOHOS:NAME=SCANBTSOHOS:0,REQATTL=MEASLST&OBJLIST& GRANP& REPMETHD& START&STOP&RECINT&LSUPDTIME&LSLOTIME& LSULOTIME; GET SCANBTSOHOS BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOS GET SCANBTSOHOS BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "scann" can be found in Appendix A. System Responses: OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANBTSOHOS BASICS: NAME=SCANBTSOHOS:scann; GET SCANBTSOHOS BASICS ACK: NAME: SCANBTSOHOS MEASLST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod 1070 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get SCANBTSOHOS BASICS:NAME=SCANBTSOHOS:0; GET SCANBTSOHOS STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOS GET SCANBTSOHOS STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SCANBTSOHOS object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "scann" can be found in Appendix A. System Responses: START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET SCANBTSOHOS BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANBTSOHOS STAT: NAME=SCANBTSOHOS:scann; GET SCANBTSOHOS STAT ACK: GET SCANBTSOHOS STAT NACK: A30808-X3247-L230-3-7619 1071 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get SCANBTSOHOS STAT:NAME=SCANBTSOHOS:0; LOCK SCANBTSOHOS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOS LOCK SCANBTSOHOS Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state LOCKED. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed, no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock SCANBTSOHOS:NAME=SCANBTSOHOS:0; NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK SCANBTSOHOS: NAME=SCANBTSOHOS:scann; LOCK SCANBTSOHOS ACK: LOCK SCANBTSOHOS NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1072 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller REMOVE SCANBTSOHOS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOS REMOVE SCANBTSOHOS Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Remove SCANBTSOHOS:NAME=SCANBTSOHOS:0, MEASOBJLST=measList(ATOISHDO); REMOVE SCANBTSOHOS: NAME=SCANBTSOHOS:scann, MEASOBJLST=; REMOVE ACK: Successful REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. WRONG_LIST_OF_MEASURE Measure not present or only one measure within database. UNSUCCESSFUL_LIST_OF_OBJECT The same object instance cannot be repeated in the objList list. A30808-X3247-L230-3-7619 1073 Commands Base Station Controller CML:BSC SET SCANBTSOHOS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOS SET SCANBTSOHOS Applicability: Phase 2. Visibility level 0. Command Description: This command sets the configuration of instance of the scanner providing measurement related to BTS outgoing handovers fromGSMto UMTS system. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: SET SCANBTSOHOS: NAME=SCANBTSOHOS:scann [,MEASLST=] [,OBJLST=] [,GRANP=] [,START=] [,STOP=] [,RECINT=]; SET ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANBTSOHOS: name = SCANBTSOHOS:<istn> commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: WRONG_LIST_OF_MEASURE The measures list cannot be empty. A measure cannot be duplicated. Measure not present or only one measure within database. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. UNSUCCESSFUL_VAR_OUT_OF_RANGE The global number of equipped scanner objects must not exceed a fixed maximum number (90). UNSUCCESSFUL_LIST_OF_OBJECT The same object instance cannot be repeated in the OBJLST list. UNSUCCESSFUL_INVALID_DATE The start date or the stop date are incorrect. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. 1074 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Set SCANBTSOHOS:NAME=SCANBTSOHOS:0,MEASLST=measList(ATOISHDO | SUOISHDO| UNOISHDO),OBJLST=(1-1)-selfAdapting(0),GRANP=MINUTES_5, START=1-Feb-2001,STOP=2-Mar-2002,RECINT=all(0); UNLOCK SCANBTSOHOS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOS UNLOCK SCANBTSOHOS Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state UNLOCKED. The validity range of the object address "scann" can be found in Appendix A. System Responses: UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNLOCK SCANBTSOHOS: NAME=SCANBTSOHOS:scann; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: A30808-X3247-L230-3-7619 1075 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Unlock SCANBTSOHOS:NAME=SCANBTSOHOS:0; ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1076 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SCANBTSTD The SCANBTSTD (Scanner BTSTD) is a scanning function on a specific set of BTSTD managed objects, and is able to report periodically the collected measurements; the raw data are collected at BSC. ADD SCANBTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTD ADD SCANBTSTD Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add measures and objects to the original configuration of a scanner previously created by the user. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. ADD SCANBTSTD: NAME=SCANBTSTD:scantdn, MEASOBJLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object have been already configured in an other scanner. WRONG_LIST_OF_MEASURE Some measures are already present inside the scanner measures list. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. Scanner is in selfAdapting mode or exceeded max number of objects. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. A30808-X3247-L230-3-7619 1077 Commands Base Station Controller CML:BSC Example of Command Execution Add SCANBTSTD:NAME=SCANBTSTD:0,MEASOBJLST=measList(TDTACCBPRO | TDNACSUCPR | TDSUIMASCA | TDATINHIRC); CREATE SCANBTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTD CREATE SCAN- BTSTD Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the SCANBTSTD object. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: CREATE SCANBTSTD: NAME=SCANBTSTD:scantdn, MEASLST= ,OBJLST= [,GRANP=] [,START=] [,STOP=] ,RECINT=; CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANBTSTD:istn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCANBTSTD: name = SCANBTSTD:istn commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the managed object must not be already created. UNSUCCESSFUL_INVALID_STATUS The measurements have to be applied to already created object instances; after the creation of the object the ADMINISTRATIVE state is UNLOCKED UNSUCCESSFUL_MEAS_ALREADY_PRESENT 1078 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: When a Restart of BSC is done, the Perfomance Measurements Data collected in the last granularity are not signicant. PM generation report follows the next rules: Reports contain only already created objects counters. If all objects under measure are not already created, a report with objects number equal to zero is always gener- ated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution Create SCANBTSTD:NAME=SCANBTSTD:0,MEASLST=allMeas(0), OBJLST=selfAdapting(0),GRANP=MINUTES_15,START=1-Jan-2003, STOP=1-Mar-2003,RECINT=all(0); The same measure on the same object has been already configured in another scanner. UNSUCCESSFUL_LIST_OF_OBJECT The OBJLIST contains more times the same object. UNSUCCESSFUL_INVALID_DATE The start date or the stop date are incorrect. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. UNSUCCESSFUL_VAR_OUT_OF_RANGE Max number of scanner exceeded. UNSUCCESSFUL_WRONG_GRANULARITY With MEASLST=allMeas(0) GRANP must be at least MINUTE_15. A30808-X3247-L230-3-7619 1079 Commands Base Station Controller CML:BSC DELETE SCANBTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTD DELETE SCAN- BTSTD Applicability: Phase 2. Visibility level 2. Command Description: The command deletes a scanner instance which has been previously created. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete SCANBTSTD:NAME=SCANBTSTD:0; DELETE SCANBTSTD: NAME=SCANBTSTD:scantdn; DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. 1080 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET SCANBTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTD GET SCANBTSTD Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSTD:NAME=SCANBTSTD:0,REQATTL=MEASLST&OBJLST&GRANP& REPMETHD&START&STOP&RECINT&LSUPDTIME&LSLOTIME&LSULOTIME; GET SCANBTSTD: NAME=SCANBTSTD:scantdn [,REQATTL=MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, LSUPDTIME, LSLOTIME, LSULOTIME]; GET ACK: NAME: SCANBTSTD MEASLST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. A30808-X3247-L230-3-7619 1081 Commands Base Station Controller CML:BSC GET SCANBTSTD BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTD GET SCANBTSTD BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSTD BASICS:NAME=SCANBTSTD:0; GET SCANBTSTD BASICS: NAME=SCANBTSTD:scantdn; GET SCANBTSTD BASICS ACK: NAME: SCANBTSTD MEASLST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET SCANBTSTD BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. 1082 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET SCANBTSTD STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTD GET SCANBTSTD STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SCANBTSTD object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSTD STAT:NAME=SCANBTSTD:0; LOCK SCANBTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTD LOCK SCANBTSTD Applicability: Phase 2. GET SCANBTSTD STAT: NAME=SCANBTSTD:scantdn; GET SCANBTSTD STAT ACK: GET SCANBTSTD STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. LOCK SCANBTSTD: NAME=SCANBTSTD:scantdn; A30808-X3247-L230-3-7619 1083 Commands Base Station Controller CML:BSC Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock SCANBTSTD:NAME=SCANBTSTD:0; REMOVE SCANBTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTD REMOVE SCAN- BTSTD Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove measures and objects from the original configuration of a scanner previously created by the user. The validity range of the object address "scantdn" can be found in Appendix A. LOCK SCANBTSTD ACK: LOCK SCANBTSTD NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. REMOVE SCANBTSTD: NAME=SCANBTSTD:scantdn, MEASOBJLST=; 1084 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Remove SCANBTSTD:NAME=SCANBTSTD:0,MEASOBJLST=measList(TDTAC- CBPRO | TDNACSUCPR); SET SCANBTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTD SET SCANBTSTD Applicability: Phase 2. Visibility level 2. Command Description: This command is used to change the parameter values, previously defined by the user by means of a create command, for the instance scantdn of the SCANBTSTD object. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scantdn" can be found in Appendix A. REMOVE ACK: SUCCESSFUL REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. WRONG_LIST_OF_MEASURE The measure in measlist is not present in database or only one measure in the allowed range of values. UNSUCCESSFUL_LIST_OF_OBJECT The object in objlist is not present in the database or only one object in the allowed range of values. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. SET SCANBTSTD: NAME=SCANBTSTD:scantdn [,MEASLST=] [,OBJLST=] [,GRANP=] [,START=] [,STOP=] [,RECINT=]; A30808-X3247-L230-3-7619 1085 Commands Base Station Controller CML:BSC System Responses: SET ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANBTSTD: name = SCANBTSTD:<istn> commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object has been already configured in another scanner. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. UNSUCCESSFUL_INVALID_DATE The start date or the stop date are incorrect. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_WRONG_LIST_OF_MEASURE The measure list cannot be empty UNSUCCESSFUL_WRONG_GRANULARITY With MEASLST=allMeas(0) GRANP must be at least MINUTE_15. 1086 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: When a Restart of BSC is done, the Perfomance Measurements Data collected in the last granularity are not signicant. PM generation report follows the next rules: Reports contain only already created objects counters. If all objects under measure are not already created, a report with objects number equal to zero is always gener- ated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution Set SCANBTSTD:NAME=SCANBTSTD:0,MEASLST=allMeas(0),OBJLST=self- Adapting(0), GRANP=MINUTES_15,START=1-Jan-2003,STOP=1-Mar- 2003,RECINT=all(0); UNLOCK SCANBTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTD UNLOCK SCAN- BTSTD Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. UNLOCK SCANBTSTD: NAME=SCANBTSTD:scantdn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. A30808-X3247-L230-3-7619 1087 Commands Base Station Controller CML:BSC Example of Command Execution Unlock SCANBTSTD:NAME=SCANBTSTD:0; 1088 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SCANBTSTDIHDO The SCANBTSTDIHDO (Scanner BTSTD Incoming HandOver) represents a scanning function on a specific set of origination/destination cells pairs involved in incoming handovers, and is able to report periodically the collected measurements; raw data are collected at BSC. ADD SCANBTSTDIHDO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDIHDO ADD SCANBTSTDIHDO Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add measures and objects to the original configuration of a scanner previously created by the user. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: ADD SCANBTSTDIHDO: NAME=SCANBTSTDIHDO:scantdn, MEASOBJLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object has been already configured in another scanner. WRONG_LIST_OF_MEASURE Some measures are already present within scanner UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. Scanner is in selfAdapting mode or exceeded max number of objects. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. A30808-X3247-L230-3-7619 1089 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Add SCANBTSTDIHDO:NAME=SCANBTSTDIHDO:0,MEASOBJLST=(0-0)-self- Adapting(0); CREATE SCANBTSTDIHDO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDIHDO CREATE SCANBTSTDIHDO Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the SCANNER of BTSTD Incoming Handover class. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: CREATE SCANBTSTDIHDO: NAME=SCANBTSTDIHDO:scantdn, MEASLST= ,OBJLST= [,GRANP=] [,START=] [,STOP=] ,RECINT=; CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANBTSTDIHDO:istn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCANBTSTDIHDO: name = SCANBTSTDIHDO:istn commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the managed object must not be already created. 1090 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: When a Restart of BSC is done, the Perfomance Measurements Data collected in the last granularity are not signicant. PM generation report follows the next rules: Reports contain only already created objects counters. If all objects under measure are not created, a report with objects number equal to zero is always generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. UNSUCCESSFUL_INVALID_STATUS The measurements have to be applied to already created object instances; after the creation of the object the ADMINISTRATIVE state is UNLOCKED. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object has been already configured in another scanner. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same target BTSTD more times. On a single adjacent list the same ADJC object is present more times. UNSUCCESSFUL_WRONG_LIST_OF_MEASURE The measure list cannot be empty. UNSUCCESSFUL_INVALID_DATE The start date or the stop date are incorrect. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of gran- ularity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_VAR_OUT_OF_RANGE Max number of scanner exceeded. A30808-X3247-L230-3-7619 1091 Commands Base Station Controller CML:BSC Example of Command Execution Create SCANBTSTDIHDO:NAME=SCANBTSTDIHDO:0,MEASLST=allMeas(0), OBJLST=(0-0)-selfAdapting(0)&(0-1)-selfAdapting(0),GRANP=MINUTES_60, START=1-Jan-2003,STOP=3-Ott-2003,RECINT=all(0); DELETE SCANBTSTDIHDO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDIHDO DELETE SCANBTSTDIHDO Applicability: Phase 2. Visibility level 2. Command Description: The command deletes a scanner instance which has been previously created. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete SCANBTSTDIHDO:NAME=SCANBTSTDIHDO:0; DELETE SCANBTSTDIHDO: NAME=SCANBTSTDIHDO:scantdn; DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. 1092 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET SCANBTSTDIHDO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDIHDOGET SCANBT- STDIHDO Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSTDIHDO:NAME=SCANBTSTDIHDO:0,REQATTL=MEASLST& OBJLST& GRANP&REPMETHD&START&STOP&RECINT&LSUPDTIME& LSLOTIME&LSULOTIME; GET SCANBTSTDIHDO: NAME=SCANBTSTDIHDO:scantdn [,REQATTL=MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, LSUPDTIME, LSLOTIME, LSULOTIME]; GET ACK: NAME: SCANBTSTDIHDO MEASLST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. A30808-X3247-L230-3-7619 1093 Commands Base Station Controller CML:BSC GET SCANBTSTDIHDO BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDIHDO GET SCANBTSTDIHDO BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSTDIHDO BASICS:NAME=SCANBTSTDIHDO:0; GET SCANBTSTDIHDO BASICS: NAME=SCANBTSTDIHDO:scantdn; GET SCANBTSTDIHDO BASICS ACK: NAME: SCANBTSTDIHDO MEASLST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET SCANBTSTDIHDO BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. 1094 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET SCANBTSTDIHDO STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDIHDO GET SCANBTSTDIHDO STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SCANBTSTDIHDO object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSTDIHDO STAT:NAME=SCANBTSTDIHDO:0; LOCK SCANBTSTDIHDO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDIHDO LOCK SCANBTSTDIHDO GET SCANBTSTDIHDO STAT: NAME=SCANBTSTDIHDO:scantdn; GET SCANBTSTDIHDO STAT ACK: GET SCANBTSTDIHDO STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. LOCK SCANBTSTDIHDO: NAME=SCANBTSTDIHDO:scantdn; A30808-X3247-L230-3-7619 1095 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock SCANBTSTDIHDO:NAME=SCANBTSTDIHDO:0; REMOVE SCANBTSTDIHDO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDIHDO REMOVE SCANBTSTDIHDO Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove measures and objects from the original configuration of a scanner previously created by the user. The validity range of the object address "scantdn" can be found in Appendix A. LOCK SCANBTSTDIHDO ACK: LOCK SCANBTSTDIHDO NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is already in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. REMOVE SCANBTSTDIHDO: NAME=SCANBTSTDIHDO:scantdn, MEASOBJLST=; 1096 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Remove SCANBTSTDIHDO:NAME=SCANBTSTDIHDO:0,MEASOBJLST= measList(TDSININIRH); SET SCANBTSTDIHDO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDIHDO SET SCANBT- STDIHDO Applicability: Phase 2. Visibility level 2. Command Description: This command is used to change the parameter values, previously defined by the user by means of a create command, for the instance scantdn of the SCANBTSTDIHDO object (Incoming Handover class). The parameter specify the values for the scheduling and reporting activities. The validity range of the object address "scantdn" can be found in Appendix A. REMOVE ACK: Successful REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed objct must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. WRONG_LIST_OF_MEASURE The measure in measlist is not present in database or only one measure in the allowed range of values. UNSUCCESSFUL_LIST_OF_OBJECT The object in objlist is not present in database or only one object in the allowed range of values. Scanner in selfadapting mode. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. SET SCANBTSTDIHDO: NAME=SCANBTSTDIHDO:scantdn [,MEASLST=] [,OBJLST=] [,GRANP=] [,START=] [,STOP=] [,RECINT=]; A30808-X3247-L230-3-7619 1097 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: 1. When a Restart of BSC is done, the Performance Measurements Data collected in the last granularity are not signicant. SET ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANBTSTDIHDO: name = SCANBTSTDIHDO:<istn> commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object has been already configured in another scanner. UNSUCCESSFUL_WRONG_LIST_OF_MEASURE The measure list cannot be empty. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. On a single adjacent list the same BTS object is present more times. UNSUCCESSFUL_INVALID_DATE The start date or the stop date are incorrect. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. 1098 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 2. The measurements have to be applied to already created object instances. Example of Command Execution Set SCANBTSTDIHDO:NAME=SCANBTSTDIHDO:0,MEASLST=measList(TDSI- NINIRH | TDAININIRH), OBJLST=(0-0)-selfAdapting(0),GRANP=MINUTES_60, START=1-Jan-2003,STOP=3-Dec-2003,RECINT=all(0); UNLOCK SCANBTSTDIHDO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDIHDO UNLOCK SCANBTSTDIHDO Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock SCANBTSTDIHDO:NAME=SCANBTSTDIHDO:0; UNLOCK SCANBTSTDIHDO: NAME=SCANBTSTDIHDO:scantdn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is already in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. A30808-X3247-L230-3-7619 1099 Commands Base Station Controller CML:BSC SCANBTSTDOHDOI The SCANBTSTDOHDOI (Scanner BTSTD Outgoing HandOver to Internal cells) repre- sents a scanning function on a specific set of origination/internal-destination cells pairs involved in outgoing handovers, and is able to report periodically the collected measure- ments; the raw data are collected at BSC. ADD SCANBTSTDOHDOI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDOHDOI ADD SCANBTSTDOHDOI Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add measures and objects to the original configuration of a scanner previously created by the user. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: ADD SCANBTSTDOHDOI: NAME=SCANBTSTDOHDOI:scantdn, MEASOBJLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object has been already configured in another scanner. WRONG_LIST_OF_MEASURE Some measures are already present within scanner UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. Scanner is in selfAdapting mode or exceeded max number of objects. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. 1100 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Add SCANBTSTDOHDOI:NAME=SCANBTSTDOHDOI:0,MEASOBJLST=measList (SOUINIRH | AOUINIRH); CREATE SCANBTSTDOHDOI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDOHDOI CREATE SCANBTSTDOHDOI Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the scanner providing measurement related to BTSTD outgoing handovers to internal cells. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: CREATE SCANBTSTDOHDOI: NAME=SCANBTSTDOHDOI:scantdn, MEASLST= ,OBJLST= [,GRANP=] [,START=] [,STOP=] ,RECINT=; CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANBTSTDOHDOI:istn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCANBTSTDOHDOI: name = SCANBTSTDOHDOI:istn commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the managed object must not be already created. A30808-X3247-L230-3-7619 1101 Commands Base Station Controller CML:BSC Application Guidelines: When a Restart of BSC is done, the Perfomance Measurements Data collected in the last granularity are not signicant. PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. UNSUCCESSFUL_INVALID_STAUTUS The measurements have to be applied to already equipped object instances; after the creation of the object the ADMINISTRATIVE state is UNLOCKED UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object has been already configured in another scanner. UNSUCCESSFUL_WRONG_LIST_OF_MEASURE The measure list cannot be empty. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same target BTSTD more times. On a single adjacent list the same ADJC object is present more times. INVALID_DATE The start date or the stop date are incorrect UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_VAR_OUT_OF_RANGE Max number of scanner exceeded. 1102 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Create SCANBTSTDOHDOI:NAME=SCANBTSTDOHDOI:0,MEASLST=allMeas(0), OBJLST=(0-0)-SelfAdapting(0),GRANP=MINUTES_30,START=1-Jan-2003,STOP=1- Mar-2003,RECINT=all(0); A30808-X3247-L230-3-7619 1103 Commands Base Station Controller CML:BSC DELETE SCANBTSTDOHDOI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDOHDOI DELETE SCANBTSTDOHDOI Applicability: Phase 2. Visibility level 2. Command Description: The command deletes a scanner instance which has been previously created. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete SCANBTSTDOHDOI:NAME=SCANBTSTDOHDOI:0; DELETE SCANBTSTDOHDOI: NAME=SCANBTSTDOHDOI:scantdn; DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. 1104 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET SCANBTSTDOHDOI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDOHDOI GET SCANBTSTDOHDOI Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSTDOHDOI:NAME=SCANBTSTDOHDOI:0,REQATTL=MEASLST& OBJLST&GRANP&REPMETHD&START&STOP&RECINT&LSUPDTIME& LSLOTIME&LSULOTIME; GET SCANBTSTDOHDOI: NAME=SCANBTSTDOHDOI:scantdn [,REQATTL= MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, LSUPDTIME, LSLOTIME, LSULOTIME]; GET ACK: NAME: SCANBTSTDOHDOI MEASLST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. A30808-X3247-L230-3-7619 1105 Commands Base Station Controller CML:BSC GET SCANBTSTDOHDOI BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDOHDOI GET SCANBTSTDOHDOI BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSTDOHDOI BASICS:NAME=SCANBTSTDOHDOI:0; GET SCANBTSTDOHDOI BASICS: NAME=SCANBTSOHOI:scantdn; GET SCANBTSTDOHDOI BASICS ACK: NAME: SCANBTSTDOHDOI MEASLST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET SCANBTSTDOHDOI BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. 1106 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET SCANBTSTDOHDOI STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDOHDOI GET SCANBTSTDOHDOI STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SCANBTSTDOHDOI object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSTDOHDOI STAT:NAME=SCANBTSTDOHDOI:0; LOCK SCANBTSTDOHDOI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDOHDOI LOCK SCANBTSTDOHDOI GET SCANBTSTDOHDOI STAT: NAME=SCANBTSTDOHDOI:scantdn; GET SCANBTSTDOHDOI STAT ACK: GET SCANBTSTDOHDOI STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. LOCK SCANBTSTDOHDOI: NAME=SCANBTSTDOHDOI:scantdn; A30808-X3247-L230-3-7619 1107 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock SCANBTSTDOHDOI:NAME=SCANBTSTDOHDOI:0; REMOVE SCANBTSTDOHDOI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDOHDOI REMOVE SCANBTSTDOHDOI Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove measures and objects from the original configuration of a scanner previously created by the user. The validity range of the object address "scantdn" can be found in Appendix A. LOCK SCANBTSTDOHDOI ACK: LOCK SCANBTSTDOHDOI NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. REMOVE SCANBTSTDOHDOI: NAME=SCANBTSTDOHDOI:scantdn, MEASOB- JLST=; 1108 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Remove SCANBTSTDOHDOI:NAME=SCANBTSTDOHDOI:0,MEASOBJLST= MeasList(TDAOUINIRH | TDUNINHOIE); SET SCANBTSTDOHDOI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDOHDOI SET SCANBTSTDOHDOI Applicability: Phase 2. Visibility level 2. Command Description: This command is used to change the parameter values, previously defined by the user by means of a create command, for the instance scantdn of the SCANBTSTDOHDOI object (outgoing handovers to internal cells). The parameters specify the values for the scheduling and reporting activities. REMOVE ACK: Successful REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. WRONG_LIST_OF_MEASURE The measure in measlist is not present in database or only one measure in the allowed ranges of values. UNSUCCESSFUL_LIST_OF_OBJECT The object in objlist is not present in database or only one object in the allowed range of values. Scanner in selfadapting mode. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. SET SCANBTSTDOHDOI: NAME=SCANBTSTDOHDOI:scantdn [,MEASLST=] [,OBJLST=] [,GRANP=] [,START=] [,STOP=] [,RECINT=]; A30808-X3247-L230-3-7619 1109 Commands Base Station Controller CML:BSC The validity range of the object address "scantdn" can be found in Appendix A. System Responses: SET ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANBTSTDOHDOI: name = SCANBTSTDOHDOI:<istn> commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created INVALID_STATUS The Scanner must be in Locked state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object has been already configured in another scanner. UNSUCCESSFUL_WRONG_LIST_OF_MEASURE The measure list cannot be empty UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same target BTSTD more times. On a single adjacent list the same ADJC object is present more times. Scanner in selfAdapting mode. INVALID_DATE The start date or the stop date are incorrect. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. 1110 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: When a Restart of BSC is done, the Perfomance Measurements Data collected in the last granularity are not signicant. PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution: Set SCANBTSTDOHDOI:NAME=SCANBTSTDOHDOI:0,MEASLST=allMeas(0), OBJLST=(1-1)-selfAdapting(0),GRANP=MINUTES_30,START=1-Jan-2003, STOP=1-Mar-2003,RECINT=all(0); UNLOCK SCANBTSTDOHDOI Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDOHDOI UNLOCK SCANBTSTDOHDOI Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock SCANBTSTDOHDOI:NAME=SCANBTSTDOHDOI:0; UNLOCK SCANBTSTDOHDOI: NAME=SCANBTSTDOHDOI:scantdn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. A30808-X3247-L230-3-7619 1111 Commands Base Station Controller CML:BSC SCANBTSTDOHDON The SCANBTSTDOHDON (Scanner BTSTD Outgoing HandOver to Neighbour cells) represents a scanning function on a specific set of origination/neighbour-destination cells pairs involved in outgoing handovers, and is able to report periodically the collected measurements; the raw data are collected at BSC. ADD SCANBTSTDOHDON Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDOHDON ADD SCANBTSTDOHDON Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add measures and objects to the original configuration of a scanner previously created by the user. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: ADD SCANBTSTDOHDON: NAME=SCANBTSTDOHDON:scantdn, MEASOB- JLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object have been already config- ured in an other scanner. WRONG_LIST_OF_MEASURE Some measures are already present within scanner. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same target BTSTD more times. On a single adjacent list the same TGTBTSTD object is present more times. 1112 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Add SCANBTSTDOHDON:NAME=SCANBTSTDOHDON:0,MEASOBJLST=measList (TDATINBHDO | TDSUINBHDO); CREATE SCANBTSTDOHDON Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDOHDON CREATE SCANBTSTDOHDON Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the scanner providing measurement related to BTSTDoutgoing handovers to neighbour cells. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Scanner is in selfAdapting mode or exceeded max number of objects. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. CREATE SCANBTSTDOHDON: NAME=SCANBTSTDOHDON:scantdn, MEASLST= ,OBJLST= [,GRANP=] [,START=] [,STOP=] ,RECINT=; CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANBTSTDOHDON:istn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCANBTSTDOHDON: name = SCANBTSTDOHDON:istn commandResponse = SUCCESSFUL A30808-X3247-L230-3-7619 1113 Commands Base Station Controller CML:BSC Application Guidelines: When a Restart of BSC is done, the Perfomance Measurements Data collected in the last granularity are not signicant. PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated; CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the managed object must not be already created. UNSUCCESSFUL_INVALID_STATUS The measurements have to be applied to already equipped object instances; after the creation of the object the ADMINISTRATIVE state is UNLOCKED. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object has been already configured in another scanner. UNSUCCESSFUL_WRONG_LIST_OF_MEASURE The measure list cannot be empty. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same target BTSTD more times. On a single adjacent list the same TGTBTSTD object is present more times. UNSUCCESSFUL_INVALID_DATE The start date or the stop date are incorrect. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_VAR_OUT_OF_RANGE Max number of scanner exceeded. 1114 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution Create SCANBTSTDOHDON:NAME=SCANBTSTDOHDON:0,MEASLST=allMeas(0), OBJLST=(0-0)-SelectObject(1&2)&(1-0)-SelfAdapting(0)&(2-0)-SelfAdapting(0)&(3-0)- SelectObject(1&2&3),GRANP=MINUTES_60,START=1-Jan-2003,STOP=1-Mar- 2003,RECINT=all(0); DELETE SCANBTSTDOHDON Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDOHDON DELETE SCANBTSTDOHDON Applicability: Phase 2. Visibility level 2. Command Description: The command deletes a scanner instance which has been previously created. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. DELETE SCANBTSTDOHDON: NAME=SCANBTSTDOHDON:scantdn; DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. A30808-X3247-L230-3-7619 1115 Commands Base Station Controller CML:BSC Example of Command Execution Delete SCANBTSTDOHDON:NAME=SCANBTSTDOHDON:0; 1116 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET SCANBTSTDOHON Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDOHDON GET SCANBTSTDOHDON Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSTDOHDON:NAME=SCANBTSTDOHDON:0,REQATTL=MEASLST& OBJLIST& GRANP& REPMETHD&START&STOP&RECINT&LSUPDTIME& LSLOTIME& LSULOTIME; GET SCANBTSTDOHDON: NAME=SCANBTSTDOHDON:scantdn [,REQATTL= MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, LSUPDTIME, LSLOTIME, LSULOTIME]; GET ACK: NAME: SCANBTSTDOHDON MEASLST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. A30808-X3247-L230-3-7619 1117 Commands Base Station Controller CML:BSC GET SCANBTSTDOHDON BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDOHDON GET SCANBTSTDOHDON BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSTDOHDON BASICS:NAME=SCANBTSTDOHDON:0; GET SCANBTSTDOHDON BASICS: NAME=SCANBTSOHON:scantdn; GET SCANBTSTDOHDON BASICS ACK: NAME: SCANBTSTDOHDON MEASLST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET SCANBTSTDOHDON BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. 1118 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET SCANBTSTDOHDON STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDOHDON GET SCANBTSTDOHDON STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SCANBTSTDOHDON object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANBTSTDOHDON STAT:NAME=SCANBTSTDOHDON:0; LOCK SCANBTSTDOHDON Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDOHDON LOCK SCANBTSTDOHDON GET SCANBTSTDOHDON STAT: NAME=SCANBTSTDOHDON:scantdn; GET SCANBTSTDOHDON STAT ACK: GET SCANBTSTDOHDON STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. LOCK SCANBTSTDOHDON: NAME=SCANBTSTDOHDON:scantdn; A30808-X3247-L230-3-7619 1119 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock SCANBTSTDOHDON:NAME=SCANBTSTDOHDON:0; REMOVE SCANBTSTDOHDON Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDOHDON REMOVE SCANBTSTDOHDON Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove measures and objects from the original configuration of a scanner previously created by the user. The validity range of the object address "scantdn" can be found in Appendix A. LOCK SCANBTSTDOHDON ACK: LOCK SCANBTSTDOHDON NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. REMOVE SCANBTSTDOHDON: NAME=SCANBTSTDOHDON:scantdn, MEASOB- JLST=; 1120 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Remove SCANBTSTDOHDON:NAME=SCANBTSTDOHDON:0,MEASOBJLST= measList(TDATINBHDO); SET SCANBTSTDOHDON Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDOHDON SET SCANBTSTDOHDON Applicability: Phase 2. Visibility level 2. Command Description: This command is used to change the parameter values, previously defined by the user by means of a create command, for the instance scantdn of the SCANBTSTDOHDON object (outgoing handovers to neighbour cells). REMOVE ACK: Successful REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. WRONG_LIST_OF_MEASURE The measure in measlist is not present in database or only one measure in the allowed range of values UNSUCCESSFUL_LIST_OF_OBJECT The object in objlist is not present in database or only one object in the allowed range of values The object list must contain at least one object under measure. Scanner in selfadapting mode. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. SET SCANBTSTDOHDON: NAME=SCANBTSTDOHDON:scantdn [,MEASLST=] [,OBJLST=] [,GRANP=] [,START=] [,STOP=] [,RECINT=]; A30808-X3247-L230-3-7619 1121 Commands Base Station Controller CML:BSC The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: SET ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANBTSTDOHDON: name = SCANBTSTDOHDON:<istn> commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object has been already configured in another scanner. UNSUCCESSFUL_WRONG_LIST_OF_MEASURE The measure list cannot be empty. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same target BTSTD more times. On a single adjacent list the same TGTBTSTD object is present more times. UNSUCCESSFUL_INVALID_DATE The start date or the stop date are incorrect. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. 1122 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: When a Restart of BSC is done, the Perfomance Measurements Data collected in the last granularity are not signicant. PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution Set SCANBTSTDOHDON:NAME=SCANBTSTDOHDON:0,MEASLST=measList (TDATINBHDO | TDSUINBHDO),OBJLST=(0-0)-SelfAdapting(0)&(1-0)-SelectOb- ject(1&2&3&4),GRANP=MINUTES_15,START=1-Jan-2003,STOP=1-Mar- 2003,RECINT=daily(0-0-5-0&18-0-23-0); UNLOCK SCANBTSTDOHDON Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSTDOHDON UNLOCK SCANBTSTDOHDON Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. UNLOCK SCANBTSTDOHDON: NAME=SCANBTSTDOHDON:scantdn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. A30808-X3247-L230-3-7619 1123 Commands Base Station Controller CML:BSC Example of Command Execution Unlock SCANBTSTDOHDON:NAME=SCANBTSTDOHDON:0; 1124 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SCANCHAN The SCANCHAN (Scanner Channel) represents a scanning function on a specific set of CHAN objects, and is able to report periodically the collected measurements; the raw data are collected at BTSE and forwarded to BSC. ADD SCANCHAN Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANCHAN ADD SCANCHAN Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: ADD SCANCHAN: NAME=SCANCHAN:scann, MEASOBJLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object have been already configured in an other scanner. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. Exceeded max number of objects. No more than 10 TRXs of the same BTSMcan be specified among all SCANCHAN instances. No more than 80 channels must be under measure among all SCANCHAN instances. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. A30808-X3247-L230-3-7619 1125 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Add SCANCHAN:NAME=SCANCHAN:43,MEASOBJLST=1-1-0-list(Chan2); CREATE SCANCHAN Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANCHAN CREATE SCANCHAN Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the scanner of SCANCHAN objetc. The parameter specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: CREATE SCANCHAN: NAME=SCANCHAN:scann ,OBJLST= [,START=] [,STOP=] ,RECINT=; CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANCHAN:istn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCANCHAN: name = SCANCHAN:istn commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: UNSUCCESSFUL_VAR_OUT_OF_RANGE Max number of scanner exceeded. UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. 1126 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: Regarding Abis measurements, PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, no report is generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within START_DATE and STOP_DATE attributes values. Example of Command Execution Create SCANCHAN:NAME=SCANCHAN:0, OBJLST=0-0-0-list(chan7)&1-1-4-list(chan6),START=1-Jan-2001, STOP=2-Feb-2002,RECINT=all(0); DELETE SCANCHAN Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANCHAN DELETE SCANCHAN UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. No more than 10 TRXs of the same BTSM can be specified among all SCANCHAN instances. No more than 80 channels must be under measure among all SCANCHAN instances. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. DELETE SCANCHAN: NAME=SCANCHAN:scann; A30808-X3247-L230-3-7619 1127 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 2. Command Description: The command deletes a scanner instance which has been previously created. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete SCANCHAN:NAME=SCANCHAN:0; GET SCANCHAN Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANCHAN GET SCANCHAN Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a SCANCHAN, the relative object instance must be in LOCKED state GET SCANCHAN: NAME=SCANCHAN:scann [,REQATTL=MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, LSUPDTIME, LSLOTIME, LSULOTIME]; 1128 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANCHAN:NAME=SCANCHAN:0,REQATTL=MEASLST&OBJLIST&GRANP& REPMETHD& START&STOP&RECINT&LSUPDTIME&LSLOTIME&LSULOTIME; GET SCANCHAN BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANCHAN GET SCANCHAN BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "scann" can be found in Appendix A. GET ACK: NAME: SCANCHAN MEASLIST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANCHAN BASICS: NAME=SCANCHAN:scann; A30808-X3247-L230-3-7619 1129 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Get SCANCHAN BASICS:NAME=SCANCHAN:0; GET SCANCHAN STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANCHAN GET SCANCHAN STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SCANCHN object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). GET SCANCHAN BASICS ACK: NAME: SCANCHAN MEASLIST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET SCANCHAN BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANCHAN STAT: NAME=SCANCHAN:scann; 1130 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANCHAN STAT:NAME=SCANCHAN:0; LOCK SCANCHAN Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANCHAN LOCK SCANCHAN Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). GET SCANCHAN STAT ACK: GET SCANCHAN STAT NACK. NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK SCANCHAN: NAME=SCANCHAN:scann; LOCK SCANCHAN ACK: LOCK SCANCHAN NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1131 Commands Base Station Controller CML:BSC Example of Command Execution Lock SCANCHAN:NAME=SCANCHAN:0; REMOVE SCANCHAN Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANCHAN REMOVE SCANCHAN Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Remove SCANCHAN:NAME=SCANCHAN:0,MEASOBJLST=0-1-4-list(Chan1); REMOVE SCANCHAN: NAME=SCANCHAN:scann, MEASOBJLST=; REMOVE ACK: Successful REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_LIST_OF_OBJECT The object list must contain at least one object under measure. Object under measure must be present within database. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. 1132 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SET SCANCHAN Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANCHAN SET SCANCHAN Applicability: Phase 2. Visibility level 2. Command Description: This command sets the configuration of instance of the scanner of SCANCHAN object. The parameter specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: SET SCANCHAN NAME=SCANCHAN:scann [,OBJLST=] [,START=] [,STOP=] [,RECINT=]; SET ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANCHAN: name = SCANCHAN:<istn> commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. No more than 10 TRXs of the same BTSM can be specified among all SCANCHAN instances. No more than 80 channels must be under measure among all SCANCHAN instances. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION A30808-X3247-L230-3-7619 1133 Commands Base Station Controller CML:BSC Application Guidelines: Regarding Abis measurements, PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, no report is generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within START_DATE and STOP_DATE attributes values. Example of Command Execution Set SCANCHAN:NAME=SCANCHAN:0,OBJLST=1-1-1-allTch(0), START=11-Dec-2001,STOP=2-Feb-2002,RECINT=all(0); UNLOCK SCANCHAN Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANCHAN UNLOCK SCANCHAN Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scann" can be found in Appendix A. System Responses: Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNLOCK SCANCHAN: NAME=SCANCHAN:scann; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1134 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution UNLOCK SCANCHAN:NAME=SCANCHAN:0; A30808-X3247-L230-3-7619 1135 Commands Base Station Controller CML:BSC SCANCO The SCANCOobject is the scanner complex control and it is used to have a report of all the scanner functions. GETINFO SCANCO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANCO GETINFO SCANCO Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve a list of the created scanners and for each scanner its most important data. The information provided in the report are the following: The number of congured scanners The current Performance Measurement logle size The current Performance Measurement temporary logle size The maximum Performance Measurement logle size The esteem of a daily usage which depends on the number and the attributes of already congured SCAN objects The automatic adaptation enabling Scanner id Measure class Scanner states and statuses: AST, AVS Reporting type Granularity A daily foreseen le size or a daily foreseen number of measurement reports Start date Stop date Periodicity Amount of objects dened Automatic adaptation activation The validity range of the object address "scancon" can be found in Appendix A. System Responses: GETINFO SCANCO:NAME=SCANCO:0; (* REPLAY OF THE BSC *) BSC_CONTROLLER -> LMT_LOCAL 11:41:14 22/03/1999 *** RESPONSE TO JOB 1 *** GETINFO REPORT ACK SCANCO: GETINFO SCANCO: NAME=SCANCO:scancon; 1136 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller NAME = SCANCO:0 SCANNER DATA VALUES: NUMBER OF SCANNERS CONFIGURED: 3 CURRENT SIZE OF TMP FILE: 9 KBYTES MAXIMUM SIZE OF LOG FILE: 42 KBYTES SCANNER ATTRIBUTES LIST: NAME: SCANBTS:3 ADMINISTRATIVE STATE: UNLOCKED AVAILABILITY STATUS: NONE GRANULARITY PERIOD: FIFTEEN_MIN REPORT TYPE: BY_EVENT AUTOMATIC ADAPTION ACTIVATION: TRUE START DATE: 01-JAN-1995 STOP DATE: 31-DEC-2099 PERIOD TYPE: ALWAYS_ACTIVE NUMBER OF OBJECTS: 2 NUMBER OF MEASUREMENTS: 1 NAME: SCANBTS:4 ADMINISTRATIVE STATE: UNLOCKED AVAILABILITY STATUS: NONE GRANULARITY PERIOD: SIXTY_MIN REPORT TYPE: BY_EVENT AUTOMATIC ADAPTION ACTIVATION: TRUE START DATE: 31-JAN-1995 STOP DATE: 6-DEC-2099 PERIOD TYPE: WEEKLY_SCHED NUMBER OF OBJECTS: 1 NUMBER OF MEASUREMENTS: 58 ... ... NAME: SCANBSC:12 ADMINISTRATIVE STATE: UNLOCKED AVAILABILITY STATUS: NONE GRANULARITY PERIOD: FIVE_MIN REPORT TYPE: BY_FILE AUTOMATIC ADAPTION ACTIVATION: TRUE START DATE: 31-JAN-1995 STOP DATE: 6-DEC-2099 PERIOD TYPE: ALWAYS_ACTIVE NUMBER OF OBJECTS: 1 NUMBER OF MEASUREMENTS: 1 END OF REPORT GETINFO SCANCO NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** A30808-X3247-L230-3-7619 1137 Commands Base Station Controller CML:BSC Get Info Report Nack SCANCO: name = SCANCO:0 nackCause = <nack cause> Application Guidelines: Due to the amount of information to be provided, it may be required to produce several reports. Example of Command Execution Getinfo SCANCO:NAME=SCANCO:0; UPLMEAS SCANCO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANCO UPLMEAS SCANCO Applicability: Phase 2. Visibility level 3. Command Description: This command allows to upload, from BSC disk to LMT disk, the measure files. The validity range of the object address "scancon" can be found in Appendix A. System Responses: NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. UPLMEAS SCANCO: NAME=SCANCO:scancon ,DESTDIR= , OVERWRITE=; UPLMEAS ACK: UPLMEAS NACK: NACK CAUSES: DIRECTORY_NOT_FOUND FILE_NOT_FOUND UPLOAD_ALREADY_IN_PROGRESS_NCK The command is occurred when another UPLOAD procedure is in progress. 1138 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. If the scannerlogle is uploaded with OVERWRITE parameter set at NOand the le already exists on the LMT disk, the LMT renames the existing one to oldfilename_DayMonthYearHourMinute.Thesameextention and stores the uploaded one to the disk. 2. If the user aborts the upload command or the link (between LMT and BSC) falls down, then it is no more possible to upload the same le: a new measure le will be created until new log les will be produced inside BSC. Example of Command Execution UPLMEAS SCANCO:NAME=SCANCO:0,DESTDIR="C:\Measure",FILE="General", OVERWRITE=NO; A30808-X3247-L230-3-7619 1139 Commands Base Station Controller CML:BSC SCANCTRX The SCANCTRX (Scanner Correlated TRX) represents a scanning function on a specific set of TRX managed objects, and is able to report periodically the collected measurements; the raw data are collected at BTSE and forwarded to BSC. ADD SCANCTRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANCTRX ADD SCANCTRX Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Add SCANCTRX:NAME=SCANCTRX:0,MEASOBJLST=5-17-22; ADD SCANCTRX: NAME=SCANCTRX:scann, MEASOBJLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object have been already configured in an other scanner. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. Scanner is in selfAdapting mode or exceeded max number of objects. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. 1140 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller CREATE SCANCTRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANCTRX CREATE SCANCTRX Applicability: Phase 2. Visibility level 2. Command Description: This command creates an instance of the scanner of SCANCTRX object. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: CREATE SCANCTRX: NAME=SCANCTRX:scann, OBJLST= [,START=] [,STOP=], RECINT= [,RXLVR=] [,TIMADVR=] [,FER=] [,FERSERTYPE=]; CREATE ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANCTRX: name = SCANCTRX:<istn> commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: UNSUCCESSFUL_VAR_OUT_OF_RANGE Max number of scanner exceeded. UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. UNSUCCESSFUL_LIST_OF_OBJECT The OBJLIST contains the same object more times. UNSUCCESSFUL_INVALID_ATTRIBUTES RXLVR, TIMADVR, FER attributes values must be in ascendent order. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION A30808-X3247-L230-3-7619 1141 Commands Base Station Controller CML:BSC Application Guidelines: Regarding Abis measurements, PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, no report is generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within START_DATE and STOP_DATE attributes values. Example of Command Execution Create SCANCTRX:NAME=SCANCTRX:0,OBJLST=selfAdapting(0), START=1-Jan-2001,STOP=1-Jan-2002,RECINT=all(0),RXLVR=7-15-23-31-39-47-55, TIMADVR=1-2-3-4-5-6-7,FER=10-20-30-40-50-100-200,FERSERTYPE=TCH_FULL; DELETE SCANCTRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANCTRX DELETE SCANCTRX Applicability: Phase 2. Visibility level 2. Command Description: The command deletes a scanner instance which has been previously created. The validity range of the object address "scann" can be found in Appendix A. System Responses: Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. UNSUCCESSFUL_TIMEFRAME_INCORRECT DELETE SCANCTRX: NAME=SCANCTRX:scann; DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined 1142 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Delete SCANCTRX:NAME=SCANCTRX:0; GET SCANCTRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANCTRX GET SCANCTRX Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. The validity range of the object address "scann" can be found in Appendix A. System Responses: New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a SCANCTRX, the relative object instance must be in LOCKED state. GET SCANCTRX: NAME=SCANCTRX:scann [,REQATTL= MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, RXLVR, TIMADVR, FER, FERSERTYPE, LSUPDTIME, LSLOTIME, LSULOTIME]; GET ACK: NAME: SCANCTRX MEASLIST: measureList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime A30808-X3247-L230-3-7619 1143 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get SCANCTRX:NAME=SCANCTRX:0,REQATTL=MEASLST&OBJLST& GRANP&REPMETHD&START&STOP&RECINT&RXLVR&TIMADVR&FER& FERSERTYPE&LSUPDTIME&LSLOTIME& LSULOTIME; GET SCANCTRX BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANCTRX GET SCANCTRX BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "scann" can be found in Appendix A. System Responses: RXLVR rxLevRanges TIMADVR timingAdvanceRanges FER frameErasureRate FERSERTYPE ferServiceType GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANCTRX BASICS: NAME=SCANCTRX:scann; GET SCANCTRX BASICS ACK: NAME: SCANCTRX MEASLIST: measureList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime RXLVR: rxLevRanges 1144 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get SCANCTRX BASICS:NAME=SCANCTRX:0; GET SCANCTRX STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANCTRX GET SCANCTRX STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SCANCTRX object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "scann" can be found in Appendix A. System Responses: TIMADVR: timingAdvanceRanges FER: frameErasureRate FERSERTYPE: ferServiceType GET SCANCTRX BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANCTRX STAT: NAME=SCANCTRX:scann; GET SCANCTRX STAT ACK: GET SCANCTRX STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1145 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get SCANCTRX STAT:NAME=SCANCTRX:0; LOCK SCANCTRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANCTRX LOCK SCANCTRX Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock SCANCTRX:NAME=SCANCTRX:0; REMOVE SCANCTRX LOCK SCANCTRX: NAME=SCANCTRX:scann; LOCK SCANCTRX ACK: LOCK SCANCTRX NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. REMOVE SCANCTRX: NAME=SCANCTRX:scann, MEASOBJLST=; 1146 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANCTRX REMOVE SCANCTRX Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Remove SCANCTRX:NAME=SCANCTRX:0,MEASOBJLST=1-1-1; SET SCANCTRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANCTRX SET SCANCTRX REMOVE ACK: Successful REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_LIST_OF_OBJECT The object list must contain at least one object under measure. Object under measure must be present within database or scanner in selfadapting mode. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. SET SCANCTRX: NAME=SCANCTRX:scann [,OBJLST=] [,START=] [,STOP=] [,RECINT=] [,RXLVR=] [,TIMADVR] [,FER=] [,FERSERTYPE=] ; A30808-X3247-L230-3-7619 1147 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 2. Command Description: This command sets the configuration of instance of the scanner of SCANCTRX object. The parameter specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: SET ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANCTRX: name = SCANCTRX:<istn> commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. UNSUCCESSFUL_LIST_OF_OBJECT The OBJLIST contains the same object more times. UNSUCCESSFUL_INVALID_ATTRIBUTES RXLVR, TIMADVR, FER attributes values must be in ascendent order. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. 1148 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: Regarding Abis measurements, PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, no report is generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within START_DATE and STOP_DATE attributes values. Example of Command Execution Set SCANCTRX:NAME=SCANCTRX:0,OBJLST=selfAdapting(0), START=1-Jan-2001,STOP=1-Dec-2002,RECINT=all(0),RXLVR=7-15-23-31-39-47-55, TIMADVR=1-2-3-4-5-6-7,FER=10-20-30-40-50-100-200,FERSERTYPE=TCH_FULL; UNLOCK SCANCTRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANCTRX UNLOCK SCANCTRX Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock SCANCTRX:NAME=SCANCTRX:0; UNLOCK SCANCTRX: NAME=SCANCTRX:scann; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1149 Commands Base Station Controller CML:BSC SCANFBTSM The SCANFBTSM represents a scanning class that collects measures per BTSM in order to support EDGE performances, and is able to report periodically the collected measurements; the raw data are collected at BSC. ADD SCANFBTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANFBTSM ADD SCANFBTSM Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: ADD SCANFBTSM: NAME=SCANFBTSM:scann, MEASOBJLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. WRONG_LIST_OF_MEASURE The measure list cannot be empty. A measure cannot be duplicated. Measure not present or only one measure within database. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured for another SCANFBTSM object or the same measure type is repeated in the measure list of a SCANFBTSM instance. UNSUCCESSFUL_LIST_OF_OBJECT The same object instance cannot be repeated in the OBJLIST list. If the SCANFBTSMis in selfAdapting mode it is not possible to add an object in the objects list. The maximum number of objects in the objects list has been already reached. 1150 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Add SCANFBTSM:NAME=SCANFBTSM:0,MEASOBJLST=measList(ABISPDIS | ABISPSUP); CREATE SCANFBTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANFBTSM CREATE SCANFBTSM Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the scanner of SCANFBTSM object. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: CREATE SCANFBTSM: NAME=SCANFBTSM:scann ,MEASLST= ,OBJLST= [,GRANP=] [,START=] [,STOP=] ,RECINT=; CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANFBTSM:instn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCANFBTSM: NAME = SCANFBTSM:instn commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. A30808-X3247-L230-3-7619 1151 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Create SCANFBTSM:NAME=SCANFBTSM:0,MEASLST=allMeas(0), OBJLST=selfAdapting(0),GRANP=MINUTES_30,START=1-Jan-2001, STOP=31-Dec-2001,RECINT=all(0); DELETE SCANFBTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANFBTSM DELETE SCANFBTSM WRONG_LIST_OF_MEASURE The measure list cannot be empty. A measure cannot be duplicated. Measure not present or only one measure within database. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured for another SCANFBTSM object or the same measure type is repeated in the measure list of a SCANFBTSM instance. UNSUCCESSFUL_VAR_OUT_OF_RANGE The global number of equipped scanner objects must not exceed a fixed maximum number (90). UNSUCCESSFUL_LIST_OF_OBJECT The same object instance cannot be repeated in the OBJLIST list. UNSUCCESSFUL_INVALID_DATE The start date or the stop date are incorrect. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of gran- ularity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). DELETE SCANFBTSM: NAME=SCANFBTSM:scann; 1152 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 2. Command Description: The command deletes a scanner instance which has been previously created. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete SCANFBTSM:NAME=SCANFBTSM:0; GET SCANFBTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANFBTSM GET SCANFBTSM Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a SCANFBTSM, the relative object instance must be in LOCKED state. GET SCANFBTSM: NAME=SCANFBTSM:scann [,REQATTL=MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, LSUPDTIME, LSLOTIME, LSULOTIME]; A30808-X3247-L230-3-7619 1153 Commands Base Station Controller CML:BSC The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANFBTSM:NAME=SCANFBTSM:0, REQATTL=MEASLST&OBJLST&GRANP& REPMETHD& START&STOP&RECINT& LSUPDTIME&LSLOTIME&LSULOTIME; GET SCANFBTSM BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANFBTSM GET SCANFBTSM BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "scann" can be found in Appendix A. GET ACK: NAME: SCANFBTSM MEASLST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANFBTSM BASICS: NAME=SCANFBTSM:scann; 1154 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Get SCANFBTSM BASICS:NAME=SCANFBTSM:0; LOCK SCANFBTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANFBTSMLOCK SCANFBTSM Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked. The validity range of the object address "scann" can be found in Appendix A. System Responses: GET SCANFBTSM BASICS ACK: NAME: SCANFBTSM MEASLST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET SCANFBTSM BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK SCANFBTSM: NAME=SCANFBTSM:scann; LOCK SCANFBTSM ACK: LOCK SCANFBTSM NACK: NACK CAUSES: A30808-X3247-L230-3-7619 1155 Commands Base Station Controller CML:BSC Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock SCANFBTSM:NAME=SCANFBTSM:0; REMOVE SCANFBTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANFBTSM REMOVE SCANFBTSM Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove measures from the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. REMOVE SCANFBTSM: NAME=SCANFBTSM:scann, MEASOBJLST=; REMOVE ACK: Successful REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. WRONG_LIST_OF_MEASURE The measures list cannot be empty. A measure cannot be duplicated. 1156 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Remove SCANFBTSM:NAME=SCANFBTSM:0,MEASOBJLST=measList(ABISPDIP | ABISPSUP); SET SCANFBTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANFBTSM SET SCANFBTSM Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the scanner of SCANFBTSM object. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: Measure not present or only one measure within database. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured for another SCANFBTSM object or the same measure type is repeated in the measure list of a SCANFBTSM instance. UNSUCCESSFUL_LIST_OF_OBJECT The same object instance cannot be repeated in the OBJLIST list. The specified object is not present in the objects list. If the SCANFBTSM is in selfAdapting mode it is not possible to remove an object from the objects list. There is only one object instance under measure and it is not possible to remove it. SET SCANFBTSM: NAME=SCANFBTSM:scann [,MEASLST=] [,OBJLST=] [,GRANP=] [,START=] [,STOP=] [,RECINT=]; SET ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANFBTSM:instn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status A30808-X3247-L230-3-7619 1157 Commands Base Station Controller CML:BSC Application Guidelines: None. New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANFBTSM: NAME = SCANFBTSM:instn commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. WRONG_LIST_OF_MEASURE The measure list cannot be empty. A measure cannot be duplicated. Measure not present or only one measure within database. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured for another SCANFBTSMobject or the same measure type is repeated in the measure list of a SCANFBTSM instance. UNSUCCESSFUL_VAR_OUT_OF_RANGE The global number of equipped scanner objects must not exceed a fixed maximum number (90). UNSUCCESSFUL_LIST_OF_OBJECT The same object instance cannot be repeated in the OBJLIST list. UNSUCCESSFUL_INVALID_DATE The start date or the stop date are incorrect. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of gran- ularity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. 1158 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Set SCANFBTSM:NAME=SCANFBTSM:0,MEASLST=measList(ABISPDIP | ABISPSUP),OBJLST=selfAdapting(0), GRANP=MINUTES_60,START=1-Jan- 2001,STOP=2-Jun-2002,RECINT=all(0); UNLOCK SCANFBTSM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANFBTSM UNLOCK SCANFBTSM Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock SCANFBTSM:NAME=SCANFBTSM:0; UNLOCK SCANFBTSM: NAME=SCANFBTSM:scann; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1159 Commands Base Station Controller CML:BSC SCANGPRS The SCANGPRS (Scanner GPRS) represents a scanning function on a specific set of BTS managed objects performing GPRS functions, and is able to report periodically the collected measurements; the raw data are collected at BSC. ADD SCANGPRS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRS ADD SCANGPRS Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. ADD SCANGPRS: NAME=SCANGPRS:scann, MEASOBJLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object have been already configured in an other scanner. WRONG_LIST_OF_MEASURE Trying to add a measure already present inside scanner measures list. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. Scanner is in selfAdapting mode or exceeded max number of objects. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. 1160 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Add SCANGPRS:NAME=SCANGPRS:0,MEASOBJLST=measList(NRETPDU | NATGPPAG); CREATE SCANGPRS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRS CREATE SCANGPRS Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the scanner of SCANGPRS object. The parameter specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: CREATE SCANGPRS: NAME=SCANGPRS:scann ,MEASLST= ,OBJLST= [,GRANP=] [,START=] [,STOP=] ,RECINT=; CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANGPRS:instn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCANGPRS: NAME = SCANGPRS:instn commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: UNSUCCESSFUL_VAR_OUT_OF_RANGE Max number of scanner exceeded. UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. A30808-X3247-L230-3-7619 1161 Commands Base Station Controller CML:BSC Application Guidelines: PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution Create SCANGPRS:NAME=SCANGPRS:0,MEASLST=allMeas(0), OBJLST=selfAdapting(0),GRANP=MINUTES_30,START=1-Jan-2001, STOP=31-Dec-2001,RECINT=all(0); DELETE SCANGPRS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRS DELETE SCANGPRS UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. UNSUCCESSFUL_LIST_OF_OBJECT The OBJLIST contains the same object more times. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of gran- ularity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. DELETE SCANGPRS: NAME=SCANGPRS:scann; 1162 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 2. Command Description: The command deletes a scanner instance which has been previously created. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete SCANGPRS:NAME=SCANGPRS:0; GET SCANGPRS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRS GET SCANGPRS Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a SCANGPRS, the relative object instance must be in LOCKED state. GET SCANGPRS: NAME=SCANGPRS:scann [,REQATTL=MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, LSUPDTIME, LSLOTIME, LSULOTIME]; A30808-X3247-L230-3-7619 1163 Commands Base Station Controller CML:BSC The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANGPRS:NAME=SCANGPRS:0,REQATTL=MEASLST&OBJLIST&GRANP& REPMETHD& START&STOP&RECINT&LSUPDTIME&LSLOTIME&LSULOTIME; GET SCANGPRS BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRS GET SCANGPRS BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "scann" can be found in Appendix A. GET ACK: NAME: SCANGPRS MEASLIST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANGPRS BASICS: NAME=SCANGPRS:scann; 1164 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Get SCANGPRS BASICS:NAME=SCANGPRS:0; GET SCANGPRS STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRS GET SCANGPRS STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SCANGPRS object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). GET SCANGPRS BASICS ACK: NAME: SCANGPRS MEASLIST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET SCANGPRS BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANGPRS STAT: NAME=SCANGPRS:scann; A30808-X3247-L230-3-7619 1165 Commands Base Station Controller CML:BSC The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANGPRS STAT:NAME=SCANGPRS:0; LOCK SCANGPRS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRS LOCK SCANGPRS Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). GET SCANGPRS STAT ACK: GET SCANGPRS STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK SCANGPRS: NAME=SCANGPRS:scann; LOCK SCANGPRS ACK: LOCK SCANGPRS NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1166 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Lock SCANGPRS:NAME=SCANGPRS:0; REMOVE SCANGPRS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRS REMOVE SCANGPRS Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Remove SCANGPRS:NAME=SCANGPRS:0,MEASOBJLST=measList(SUCPDTSE | NRETPDU | NATGPPAG); REMOVE SCANGPRS: NAME=SCANGPRS:scann, MEASOBJLST=; REMOVE ACK: Successful REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. WRONG_LIST_OF_MEASURE Measure not present or only one measure within database. UNSUCCESSFUL_LIST_OF_OBJECT The object list must contain at least one object under measure. Object under measure must be present within database or scanner in selfadapting mode. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. A30808-X3247-L230-3-7619 1167 Commands Base Station Controller CML:BSC SET SCANGPRS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRS SET SCANGPRS Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the scanner of SCANGPRS object. The parameter specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: SET SCANGPRS: NAME=SCANGPRS:scann [,MEASLST=] [,OBJLST=] [,GRANP=] [,START=] [,STOP=] [,RECINT=]; SET ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANGPRS:instn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANGPRS: NAME = SCANGPRS:instn commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. UNSUCCESSFUL_LIST_OF_OBJECT The OBJLIST contains the same object more times . 1168 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution Set SCANGPRS:NAME=SCANGPRS:0,MEASLST=measList(TNPDTLC| MPDTQLEN | NPMSDISQ | MEAOLPDC | NATPRRE),OBJLST=selfAdapting(0), GRANP=MINUTES_60,START=1-Jan-2001,STOP=2-Feb-2002,RECINT=all(0); UNLOCK SCANGPRS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRS UNLOCK SCANGPRS Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scann" can be found in Appendix A. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of gran- ularity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNLOCK SCANGPRS: NAME=SCANGPRS:scann; A30808-X3247-L230-3-7619 1169 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Unlock SCANGPRS:NAME=SCANGPRS:0; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1170 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SCANGPRSTD The SCANGPRSTD (Scanner GPRSTD) represents a scanning function on a specific set of BTSTD managed objects performing GPRS functions, and is able to report peri- odically the collected measurements; the raw data are collected at BSC. ADD SCANGPRSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRSTD ADD SCANG- PRSTD Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add measures and objects to the original configuration of a scanner previously created by the user. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: ADD SCANGPRSTD: NAME=SCANGPRSTD:scantdn, MEASOBJLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object have been already configured in an other scanner. WRONG_LIST_OF_MEASURE Trying to add a measure already present inside scanner measures list. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same target BTS more times. On a single adjacent list the same ADJC object is present more times. It is not possible to add an adjacents list when the adjacents list is in selfAdapting mode. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. A30808-X3247-L230-3-7619 1171 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Add SCANGPRSTD:NAME=SCANGPRSTD:0,MEASOBJLST=measList(TDNAT- PRRE | TDNSUPRRE | TDMEACTTBF); CREATE SCANGPRSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRSTD CREATE SCANGPRSTD Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the scanner of SCANGPRSTD object. The parameter specify the values for the scheduling and reporting activities. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: CREATE SCANGPRSTD: NAME=SCANGPRSTD:scantdn, MEASLST= ,OBJLST= [,GRANP=] [,START=] [,STOP=] ,RECINT=; CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANGPRSTD:istn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCANGPRSTD: name = SCANGPRSTD:istn commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created. UNSUCCESSFUL_INVALID_STATUS 1172 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: When a Restart of BSC is done, the Perfomance Measurements Data collected in the last granularity are not signicant. PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution CreateSCANGPRSTD:NAME=SCANGPRSTD:0,MEASLST=measList(TDNAVPDCH| TDNTBFRJC | TDTASAGPRS | TDTASUGPRS),OBJLST=ObjectList(0-0&1-0&2-0&3- 0),GRANP=MINUTES_30,START=1-Jan-2003,STOP=1-Mar-2003,RECINT=daily(0-0- 6-0&12-0-18-30); The measurements have to be applied to already created object instances; after the creation of the object the ADMINISTRATIVE state is UNLOCKED UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in another scanner. UNSUCCESSFUL_LIST_OF_OBJECT The OBJLIST contains more times the same object. UNSUCCESSFUL_INVALID_DATE The start date or the stop date are incorrect. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. A30808-X3247-L230-3-7619 1173 Commands Base Station Controller CML:BSC DELETE SCANGPRSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRSTD DELETE SCANGPRSTD Applicability: Phase 2. Visibility level 2. Command Description: The command deletes a scanner instance which has been previously created. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete SCANGPRSTD:NAME=SCANGPRSTD:0; DELETE SCANGPRSTD: NAME=SCANGPRSTD:scantdn; DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. 1174 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET SCANGPRSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRSTD GET SCANG- PRSTD Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANGPRSTD:NAME=SCANGPRSTD:0,REQATTL=MEASLST&OBJLST& GRANP&REPMETHD&START&STOP&RECINT&LSUPDTIME&LSLOTIME& LSULOTIME; GET SCANGPRSTD: NAME=SCANGPRSTD:scantdn [,REQATTL=MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, LSUPDTIME, LSLOTIME, LSULOTIME]; GET ACK: NAME: SCANGPRSTD MEASLST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. A30808-X3247-L230-3-7619 1175 Commands Base Station Controller CML:BSC GET SCANGPRSTDTD BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRSTD GET SCANG- PRSTD BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANGPRSTD BASICS:NAME=SCANGPRSTD:0; GET SCANGPRSTDTD BASICS: NAME=SCANGPRSTD:scantdn; GET SCANGPRSTD BASICS ACK: NAME: SCANGPRSTD MEASLST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET SCANGPRSTD BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. 1176 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET SCANGPRSTD STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRSTD GET SCANGPRSTD STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SCANGPRSTD object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANGPRSTD STAT:NAME=SCANGPRSTD:0; LOCK SCANGPRSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRSTD LOCK SCANG- PRSTD GET SCANGPRSTD STAT: NAME=SCANGPRSTD:scantdn; GET SCANGPRSTD STAT ACK: GET SCANGPRSTD STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. LOCK SCANGPRSTD: NAME=SCANGPRSTD:scantdn; A30808-X3247-L230-3-7619 1177 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock SCANGPRSTD:NAME=SCANGPRSTD:0; REMOVE SCANGPRSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRSTD REMOVE SCANGPRSTD Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove measures and objects from the original configuration of a scanner previously created by the user. The validity range of the object address "scantdn" can be found in Appendix A. LOCK SCANGPRSTD ACK: LOCK SCANGPRSTD NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The instance of the managed object is in the administra- tive state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. REMOVE SCANGPRSTD: NAME=SCANGPRSTD:scantdn, MEASOBJLST=; 1178 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Remove SCANGPRSTD:NAME=SCANGPRSTD:0,MEASOBJLST=measList (TDNAVPDCH | TDNTBFRJC | TDTASAGPRS | TDTASUGPRS | TDNRETPDU | TDNATGPPAG | TDNSUGPPAG | TDMUTHRF | TDMSTHRF | TDMUTHBS | TDMSTHBS | TDNATPRRE | TDNSUPRRE | TDMEACTTBF); SET SCANGPRSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRSTD SET SCANG- PRSTD Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the scanner of SCANGPRSTD object. The parameter specify the values for the scheduling and reporting activities. The validity range of the object address "scantdn" can be found in Appendix A. REMOVE ACK: Successful REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. WRONG_LIST_OF_MEASURE The measure in measlist is not present in database or only one measure in the allowed ranges of values UNSUCCESSFUL_LIST_OF_OBJECT The object in objlist is not present in database or only one object in the allowed ranges of values. SET SCANGPRSTD: NAME=SCANGPRSTD:scantdn [,MEASLST=] [,OBJLST=] [,GRANP=] [,START=] [,STOP=] [,RECINT=]; A30808-X3247-L230-3-7619 1179 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: When a Restart of BSC is done, the Perfomance Measurements Data collected in the last granularity are not signicant. PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated; SET ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANGPRSTD: name = SCANGPRSTD:<istn> commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object has been already configured in another scanner. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. UNSUCCESSFUL_INVALID_DATE The start date or the stop date are incorrect. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. UNSUCCESSFUL_WRONG_LIST_OF_MEASURE The measures list cannot be empty. 1180 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution Set SCANGPRSTD:NAME=SCANGPRSTD:0,MEASLST=measList(TDNAVPDCH | TDNTBFRJC | TDTASAGPRS),OBJLST=ObjectList(0-0&1-0&2-0&3-0),GRANP= MINUTES_15,START=1-Jan-2003,STOP=1-Mar-2003,RECINT=all(0); UNLOCK SCANGPRSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRSTD UNLOCK SCANGPRSTD Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock SCANGPRSTD:NAME=SCANGPRSTD:0; UNLOCK SCANGPRSTD: NAME=SCANGPRSTD:scantdn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. A30808-X3247-L230-3-7619 1181 Commands Base Station Controller CML:BSC SCANSS7L The SCANSS7L (Scanner SS7 Links) represents a scanning function on a specific set of SS7 links, and is able to report periodically the collected measurements; the raw data are collected at BSC. ACTIVATE SCANSS7L Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANSS7L ACTIVATE SCANSS7L Applicability: Phase 2. Visibility level 2. Command Description: This command provides a report of the partial results, collected after the last report, related to the instance. The report mode has been already selected in the configuration phase. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: Please note that when the ACTIVATE SCANSS7L command is executed, objects created after the end of the last completed 5 minutes granularity period, and before the beginning of the next 5 minutes granularity period (i.e. object created during the current 5 minutes granularity period) are not reported. This means that if the ACTIVATE SCANSS7L command is launched, objects created in the 5 minutes that occurs from the end of the last granularity period and the end of the current one are not displayed. ACTIVATE SCANSS7L: NAME=SCANSS7L:scann; ACTIVATE ACK: ACTIVATE NACK: NACK CAUSES: REJECTED_OTHER_COMMAND_IN_PROGRESS System busy in another PM report generation. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Scanner object is not ON_DUTY. 1182 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Activate SCANSS7L:NAME=SCANSS7L:0; ADD SCANSS7L Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANSS7L ADD SCANSS7L Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Add SCANSS7L:NAME=SCANSS7L:0,MEASOBJLST=measList(SLFAILAL); ADD SCANSS7L: NAME=SCANSS7L:scann, MEASOBJLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object have been already configured in an other scanner. WRONG_LIST_OF_MEASURE Trying to add a measure already present inside scanner measures list. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. Scanner is in selfAdapting mode or exceeded max number of objects. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. A30808-X3247-L230-3-7619 1183 Commands Base Station Controller CML:BSC CREATE SCANSS7L Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANSS7L CREATE SCANSS7L Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the scanner of SS7 links. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: CREATE SCANSS7L: NAME=SCANSS7L:scann ,MEASLST= ,OBJLST= [,GRANP=] [,REPMETHD=] [,START=] [,STOP=] ,RECINT=; CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANSS7L:istn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCANSS7L: name = SCANSS7L:istn commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: UNSUCCESSFUL_VAR_OUT_OF_RANGE Max number of scanner exceeded. UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. 1184 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The measurements have to be applied to already equipped object instances; After the creation of the object the ADMINISTRATIVE state is UNLOCKED. 2. When the attribute granularity is set at 0: the report is provided only after entering an Activate Scan Report command (ACTIVATE SCAN). the measurement results are reset after a LOCK/UNLOCK command. in case of overow the measurement results are lost and no output is given to the operator. 3. When a Restart of BSC is done, the Performance Measurements Data collected in the last granularity are not signicant. Example of Command Execution Create SCANSS7L:NAME=SCANSS7L:0,MEASLST=measList(DLKSERST), OBJLST=selfAdapting(0),GRANP=MINUTES_30,REPMETHD=BYMSG, START=1-Jan-2001,STOP=7-Jul-2002,RECINT=all(0); DELETE SCANSS7L Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANSS7L DELETE SCANSS7L Applicability: Phase 2. UNSUCCESSFUL_POOL_EXHAUSTED The number of scanner BYMSG is greater than the limitation defined (10). UNSUCCESSFUL_LIST_OF_OBJECT The OBJLIST contains the same object more times . UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. DELETE SCANSS7L: NAME=SCANSS7L:scann; A30808-X3247-L230-3-7619 1185 Commands Base Station Controller CML:BSC Visibility level 2. Command Description: The command deletes a scanner instance which has been previously created. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete SCANSS7L:NAME=SCANSS7L:0; GET SCANSS7L Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANSS7L GET SCANSS7L Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. The validity range of the object address "scann" can be found in Appendix A. DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a SCANSS7L, the relative object instance must be in LOCKED state. GET SCANSS7L: NAME=SCANSS7L:scann [,REQATTL=MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, LSUPDTIME, LSLOTIME, LSULOTIME]; 1186 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Get SCANSS7L:NAME=SCANSS7L:0,REQATTL=MEASLST&OBJLIST& GRANP&REPMETHD& START&STOP&RECINT&LSUPDTIME&LSLOTIME& LSULOTIME; GET SCANSS7L BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANSS7L GET SCANSS7L BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "scann" can be found in Appendix A. GET ACK: NAME: SCANSS7L MEASLIST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANSS7L BASICS: NAME=SCANSS7L:scann; A30808-X3247-L230-3-7619 1187 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Get SCANSS7L BASICS:NAME=SCANSS7L:0; GET SCANSS7L STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANSS7L GET SCANSS7L STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SCANSS7L object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). GET SCANSS7L BASICS ACK: NAME: SCANSS7L MEASLIST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET SCANSS7L BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANSS7L STAT: NAME=SCANSS7L:scann; 1188 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANSS7L STAT:NAME=SCANSS7L:0; LOCK SCANSS7L Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANSS7L LOCK SCANSS7L Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). GET SCANSS7L STAT ACK: GET SCANSS7L STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK SCANSS7L: NAME=SCANSS7L:scann; LOCK SCANSS7L ACK: LOCK SCANSS7L NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1189 Commands Base Station Controller CML:BSC Example of Command Execution Lock SCANSS7L:NAME=SCANSS7L:0; REMOVE SCANSS7L Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANSS7L REMOVE SCANSS7L Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Remove SCANSS7L:NAME=SCANSS7L:0,MEASOBJLST=measList(DSLUNAV | SLFAILAL); REMOVE SCANSS7L: NAME=SCANSS7L:scann, MEASOBJLST=; REMOVE ACK: Successful REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. WRONG_LIST_OF_MEASURE Measure not present or only one measure within database. UNSUCCESSFUL_LIST_OF_OBJECT The object list must contain at least one object under measure. Object under measure must be present within database or scanner in selfadapting mode. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. 1190 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SET SCANSS7L Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANSS7L LOCK SCANSS7L Applicability: Phase 2. Visibility level 2. Command Description: This command sets the configuration of instance of the SCANNERof SS7LMEAS class. The parameters specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: SET SCANSS7L: NAME=SCANSS7L:scann [,MEASLST=] [,OBJLST=] [,GRANP=] [,REPMETHD=] [,START=] [,STOP=] [,RECINT=]; SET ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANSS7L: name = SCANSS7L:<istn> commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. UNSUCCESSFUL_POOL_EXHAUSTED The number of scanner BYMSG is greater than the limitation defined (10). UNSUCCESSFUL_LIST_OF_OBJECT The OBJLIST contains the same object more times. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED A30808-X3247-L230-3-7619 1191 Commands Base Station Controller CML:BSC Application Guidelines: 1. The measurement activity status has to be in Offduty to submit the SET SCAN command. Use STOPSCAN SCAN command to set the offduty status. 2. The measurements have to be applied to already equipped object instances. 3. When a Restart of BSC is done, the Performance Measurements Data collected in the last granularity are not signicant. Example of Command Execution Set SCANSS7L:NAME=SCANSS7L:0,MEASLST=allMeas(0), OBJLST=selfAdapting(0),GRANP=MINUTES_30,REPMETHD=BYFILE, START=1-Jan-2001,STOP=22-Nov-2002,RECINT=all(0); UNLOCK SCANSS7L Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANSS7L UNLOCK SCANSS7L Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scann" can be found in Appendix A. System Responses: The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. UNLOCK SCANSS7L: NAME=SCANSS7L:scann; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE 1192 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Unlock SCANSS7L:NAME=SCANSS7L:0; The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1193 Commands Base Station Controller CML:BSC SCANTRX The SCANTRX (Scanner TRX) represents a scanning function on a specific set of TRX managed objects, and is able to report periodically the collected measurements; raw data are collected at BSC. ADD SCANTRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRX ADD SCANTRX Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Add SCANTRX:NAME=SCANTRX:0,MEASOBJLST=1-1-0; ADD SCANTRX: NAME=SCANTRX:scann, MEASOBJLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object have been already configured in an other scanner. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. Scanner is in selfAdapting mode or exceeded max number of objects. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. 1194 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller CREATE SCANTRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRX CREATE SCANTRX Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration of instance of the scanner of SCANTRX object. The parameter specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: CREATE SCANTRX: NAME=SCANTRX:scann ,MEASLST= ,OBJLST= [,GRANP=] [,START=] [,STOP=] ,RECINT=; CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANTRX:istn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCANTRX: name = SCANTRX:istn commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: UNSUCCESSFUL_VAR_OUT_OF_RANGE Max number of scanner exceeded. UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. A30808-X3247-L230-3-7619 1195 Commands Base Station Controller CML:BSC Application Guidelines: PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution Create SCANTRX:NAME=SCANTRX:0,MEASLST=TRANAVTI, OBJLST=selfAdapting(0),GRANP=MINUTES_5,START=1-Jan-2001,STOP=2-Feb- 2002, RECINT=all(0); DELETE SCANTRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRX DELETE SCANTRX Applicability: Phase 2. Visibility level 2. UNSUCCESSFUL_LIST_OF_OBJECT The OBJLIST contains the same object more times. UNSUCCESSFUL_WRONG_GRANULARITY With MEASLIST=measlist(ILUPLKIC) the GRANP attribute must be MINUTES_60. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. DELETE SCANTRX: NAME=SCANTRX:scann; 1196 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: The command deletes a scanner instance which has been previously created. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete SCANTRX:NAME=SCANTRX:0; GET SCANTRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRX GET SCANTRX Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. The validity range of the object address "scann" can be found in Appendix A. DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a SCANTRX, the relative object instance must be in LOCKED state. GET SCANTRX: NAME=SCANTRX:scann [,REQATTL=MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, LSUPDTIME, LSLOTIME, LSULOTIME]; A30808-X3247-L230-3-7619 1197 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Get SCANTRX:NAME=SCANTRX:0,REQATTL=MEASLST&GRANP&REPMETHD& START&STOP&RECINT&LSUPDTIME&LSLOTIME&LSULOTIME; GET SCANTRX BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRX GET SCANTRX BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "scann" can be found in Appendix A. GET ACK: NAME: SCANTRX MEASLIST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANTRX BASICS: NAME=SCANTRX:scann; 1198 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Get SCANTRX BASICS:NAME=SCANTRX:0; GET SCANTRX STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRX GET SCANTRX STAT Applicability: Phase 2 Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the BTSM object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "scann" can be found in Appendix A. GET SCANTRX BASICS ACK: NAME: SCANTRX MEASLIST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET SCANTRX BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SCANTRX STAT: NAME=SCANTRX:scann; A30808-X3247-L230-3-7619 1199 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Get SCANTRX STAT:NAME=SCANTRX:0; LOCK SCANTRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRX LOCK SCANTRX Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). GET SCANTRX STAT ACK: GET SCANTRX STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK SCANTRX: NAME=SCANTRX:scann; LOCK SCANTRX ACK: LOCK SCANTRX NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1200 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Lock SCANTRX:NAME=SCANTRX:0; A30808-X3247-L230-3-7619 1201 Commands Base Station Controller CML:BSC REMOVE SCANTRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRX REMOVE SCANTRX Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove measures to the original configuration of a scanner previously created by the user. The validity range of the object address "scann" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Remove SCANTRX:NAME=SCANTRX:0,MEASOBJLST=0-1-4; REMOVE SCANTRX: NAME=SCANTRX:scann, MEASOBJLST=; REMOVE ACK: Successful REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_LIST_OF_OBJECT The object list must contain at least one object under measure. Object under measure must be present within database or scanner in selfadapting mode. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. 1202 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SET SCANTRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRX SET SCANTRX Applicability: Phase 2. Visibility level 2. Command Description: This command sets the configuration of instance of the scanner of SCANTRX object. The parameter specify the values for the scheduling and reporting activities. The validity range of the object address "scann" can be found in Appendix A. System Responses: SET SCANTRX: NAME=SCANTRX:scann [,MEASLST=] [,OBJLST=] [,GRANP=] [,START=] [,STOP=] [,RECINT=]; SET ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANTRX: name = SCANTRX:<istn> commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the object instance is in LOCKED state. UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure on the same object has been already configured in an other scanner. WRONG_LIST_OF_MEASURE Empty MEASLST is not allowed. UNSUCCESSFUL_LIST_OF_OBJECT The OBJLIST contains the same object more times. UNSUCCESSFUL_WRONG_GRANULARITY With MEASLIST=measlist(ILUPLKIC) the GRANP attribute must be MINUTES_60. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. A30808-X3247-L230-3-7619 1203 Commands Base Station Controller CML:BSC Application Guidelines: PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution Set SCANTRX:NAME=SCANTRX:0,MEASLST=ILUPLKIC,OBJLST=selfAdapting(0), GRANP=MINUTES_5,START=3-Mar-2001,STOP=4-Dec-2002,RECINT=all(0); UNLOCK SCANTRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRX UNLOCK SCANTRX Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scann" can be found in Appendix A. System Responses: UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. UNSUCCESSFUL_TIMEFRAME_INCORRECT UNLOCK SCANTRX: NAME=SCANTRX:scann; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE 1204 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Unlock SCANTRX:NAME=SCANTRX:0; The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1205 Commands Base Station Controller CML:BSC SCANTRXABISTD The SCANTRXABISTD (Scanner TRXABISTD) represents a scanning function on a specific set of TRXABISTD managed objects, and is able to report periodically the collected measurements; raw data are collected at BSC. ADD SCANTRXABISTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRXABISTD ADD SCANTRXABISTD Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add objects to the original object list of a scanner previously created by the user. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Add SCANTRXABISTD:NAME=SCANTRXABISTD:0,MEASOBJLST=1-0-0&1-0-1&1- 0-2&2-0-0&2-0-1&2-0-2; ADD SCANTRXABISTD: NAME=SCANTRXABISTD:scantdn, MEASOBJLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. Scanner is in selfAdapting mode or exceeded max number of objects. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. 1206 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller CREATE SCANTRXABISTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRXABISTD CREATE SCANTRXABISTD Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration for a new instance of the SCANTRXABISTD scanner object. The parameter specify the values for the scheduling and reporting activ- ities. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: CREATE SCANTRXABISTD: NAME=SCANTRXABISTD:scantdn, OBJLST= [,GRANP=] [,START=] [,STOP=] ,RECINT=; CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANTRXABISTD:istn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCANTRXABISTD: name = SCANTRXABISTD:istn commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the managed object must not be already created. UNSUCCESSFUL_INVALID_STATUS The measurements have to be applied to already equipped object instances; after the creation of the object the ADMINISTRATIVE state is UNLOCKED UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object has been already configured in another scanner. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. A30808-X3247-L230-3-7619 1207 Commands Base Station Controller CML:BSC Application Guidelines: PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. When a Restart of BSC is done, the Perfomance Measurements Data collected in the lastgranularity are not signicant. Example of Command Execution Create SCANTRXABISTD:NAME=SCANTRXABISTD:0,OBJLST=selectObject(0-0- 0&0-0-1&0-0-2),GRANP=MINUTES_15,START=1-Jan-2003,STOP=1-Mar- 2003,RECINT=all(0); DELETE SCANTRXABISTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRXABISTD DELETE SCANTRXABISTD Applicability: Phase 2. Visibility level 2. Command Description: The command deletes a scanner instance which has been previously created. UNSUCCESSFUL_INVALID_DATE The start date or the stop date are incorrect. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. DELETE SCANTRXABISTD: NAME=SCANTRXABISTD:scantdn; 1208 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete SCANTRXABISTD:NAME=SCANTRXABISTD:0; GET SCANTRXABISTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRXABISTD GET SCANT- RXABISTD Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. The validity range of the object address "scantdn" can be found in Appendix A. DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. GET SCANTRXABISTD: NAME=SCANTRXABISTD:scantdn [,REQATTL= MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, LSUPDTIME, LSLOTIME, LSULOTIME]; A30808-X3247-L230-3-7619 1209 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Get SCANTRXABISTD:NAME=SCANTRXABISTD:0,REQATTL=MEASLST& OBJLST& GRANP&REPMETHD&START&STOP&RECINT&LSUPDTIME& LSLOTIME&LSULOTIME; GET SCANTRXABISTD BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRXABISTD GET SCANT- RXABISTD BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve all the parameter values of the BASICS group. The validity range of the object address "scantdn" can be found in Appendix A. GET ACK: NAME: SCANTRXABISTD MEASLST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. GET SCANTRXABISTD BASICS: NAME=SCANTRX:scantdn; 1210 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Get SCANTRXABISTD BASICS:NAME=SCANTRXABISTD:0; GET SCANTRXABISTD STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRXABISTD GET SCANT- RXABISTD STAT Applicability: Phase 2 Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the BTSM object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) GET SCANTRXABISTD BASICS ACK: NAME: SCANTRXABISTD MEASLST: measureList OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET SCANTRXABISTD BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. GET SCANTRXABISTD STAT: NAME=SCANTRXABISTD:scantdn; A30808-X3247-L230-3-7619 1211 Commands Base Station Controller CML:BSC Unknown Status (UNK). The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SCANTRXABISTD STAT:NAME=SCANTRXABISTD:0; LOCK SCANTRXABISTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRXABISTD LOCK SCANT- RXABISTD Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "scantdn" can be found in Appendix A. System Responses: GET SCANTRXABISTD STAT ACK: GET SCANTRXABISTD STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. LOCK SCANTRX- ABISTD: NAME=SCANTRXABISTD:scantdn; LOCK SCANTRXABISTD ACK: LOCK SCANTRXABISTD NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. 1212 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock SCANTRXABISTD:NAME=SCANTRXABISTD:0; REMOVE SCANTRXABISTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRXABISTD REMOVE SCANTRXABISTD Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove objects fromthe the list of objects of the original config- uration of a scanner previously created by the user. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. REMOVE SCANTRX- ABISTD: NAME=SCANTRXABISTD:scantdn, MEASOBJLST=; REMOVE ACK: Successful REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. UNSUCCESSFUL_LIST_OF_OBJECT The object in objlist is not present in database or only one object in the allowed ranges of values. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. A30808-X3247-L230-3-7619 1213 Commands Base Station Controller CML:BSC Example of Command Execution Remove SCANTRXABISTD:NAME=SCANTRXABISTD:0,MEASOBJLST=2-0-0&2-0- 1&2-0-2&3-0-0&3-0-1&3-0-2; SET SCANTRXABISTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRXABISTD SET SCANT- RXABISTD Applicability: Phase 2. Visibility level 2. Command Description: This command changes the configuration for an instance of SCANTRXABISTDscanner object previously created by the user. The parameter specify the values for the sched- uling and reporting activities. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: SET SCANTRXABISTD: NAME=SCANTRXABISTD:scantdn [,OBJLST=] [,GRANP=] [,START=] [,STOP=] [,RECINT=]; SET ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANTRXABISTD: name = SCANTRXABISTD:<istn> commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The measurements have to be applied to already equipped object instances; after the creation of the object the ADMINISTRATIVE state is UNLOCKED UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object has been already configured in another scanner. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. UNSUCCESSFUL_INVALID_DATE The start date or the stop date are incorrect. 1214 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: When a Restart of BSC is done, the Perfomance Measurements Data collected in the lastgranularity are not signicant. PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated. Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution Set SCANTRXABISTD:NAME=SCANTRXABISTD:0,OBJLST=selectObject(0-0-0&0- 0-1&0-0-2),GRANP=MINUTES_5,START=1-Jan-2003,STOP=1-Mar- 2003,RECINT=daily(5-0-6-0); UNLOCK SCANTRXABISTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRXABISTD UNLOCK SCANTRXABISTD Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scantdn" can be found in Appendix A. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. UNLOCK SCANTRX- ABISTD: NAME=SCANTRXABISTD:scantdn; A30808-X3247-L230-3-7619 1215 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Unlock SCANTRXABISTD:NAME=SCANTRXABISTD:0; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. 1216 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SCANTRXTD The SCANTRXTD (Scanner TRXTD) represents a scanning function on a specific set of TRXTD managed objects, and is able to report periodically the collected measure- ments; raw data are collected at BSC. ADD SCANTRXTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRXTD ADD SCANTRXTD Applicability: Phase 2. Visibility level 2. Command Description: This command allows to add objects to the original object list of a scanner previously created by the user. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Add SCANTRXTD:NAME=SCANTRXTD:0,MEASOBJLST=1-0-0&1-0-1&1-0-2&2-0- 0&2-0-1&2-0-2; ADD SCANTRXTD: NAME=SCANTRXTD:scantdn, MEASOBJLST=; ADD ACK: Successful ADD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. Scanner is in selfAdapting mode or exceeded max number of objects. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. A30808-X3247-L230-3-7619 1217 Commands Base Station Controller CML:BSC CREATE SCANTRXTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRXTD CREATE SCANTRXTD Applicability: Phase 2. Visibility level 2. Command Description: This command creates the configuration for a new instance of the SCANTRXTD scanner object. The parameter specify the values for the scheduling and reporting activ- ities. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: CREATE SCANTRXTD: NAME=SCANTRXTD:scantdn, MEASLST= ,OBJLST= [,GRANP=] [,START=] [,STOP=] ,RECINT=; CREATE ACK: STATUS_MANAGER -> SYSTEM_BROADCAST *** INFORMATION *** CHANGED STATE EVENT REPORT: NAME = SCANTRXTD:istn Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED Operational State = from NO_OPERATIONAL_STATE to ENABLED Old Availability Status = Null Status New Availability Status = Off_Duty DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Create Ack SCANTRXTD: name = SCANTRXTD:istn commandResponse = SUCCESSFUL CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the managed object must not be already created. UNSUCCESSFUL_INVALID_STATUS The measurements have to be applied to already equipped object instances; after the creation of the object the ADMINISTRATIVE state is UNLOCKED UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object has been already configured in another scanner. UNSUCCESSFUL_LIST_OF_OBJECT 1218 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated; Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. When a Restart of BSC is done, the Perfomance Measurements Data collected in the lastgranularity are not signicant. Example of Command Execution Create SCANTRXTD:NAME=SCANTRXTD:0,OBJLST=selectObject(0-0-0&0-0-1&0- 0-2),GRANP=MINUTES_15,START=1-Jan-2003,STOP=1-Mar-2003,RECINT=all(0); DELETE SCANTRXTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRXTD DELETE SCANTRXTD Applicability: Phase 2. Visibility level 2. Command Description: The command deletes a scanner instance which has been previously created. The object list contains the same object more times. UNSUCCESSFUL_INVALID_DATE The start date or the stop date are incorrect. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. DELETE SCANTRXTD: NAME=SCANTRXTD:scantdn; A30808-X3247-L230-3-7619 1219 Commands Base Station Controller CML:BSC The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete SCANTRXTD:NAME=SCANTRXTD:0; GET SCANTRXTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRXTD GET SCANTRXTD Applicability: Phase 2. Visibility level 1. Command Description: The command is used to retrieve the parameters of an existing scanner instance. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: DELETE ACK: Successful ***INFORMATION*** SCAN CHANGED STATUS: SCAN-instn Old Scan Activation: Offduty/Active/Inactive Old Scan Report: Inhibit New Scan Activation: Undefined New Scan Report: NA DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. GET SCANTRXTD: NAME=SCANTRXTD:scantdn [,REQATTL=MEASLST, OBJLST, GRANP, REPMETHD, START, STOP, RECINT, LSUPDTIME, LSLOTIME, LSULOTIME]; GET ACK: NAME: SCANTRXTD MEASLST: measureList 1220 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get SCANTRXTD:NAME=SCANTRXTD:0,REQATTL=MEASLST&OBJLST& GRANP&REPMETHD&START&STOP&RECINT&LSUPDTIME&LSLOTIME&LSULO- TIME; GET SCANTRXTD BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRXTD GET SCANTRXTD BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve all the parameter values of the BASICS group. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: OBJLST: objectList GRANP: granularityPeriod REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. GET SCANTRXTD BASICS: NAME=SCANTRX:scantdn; GET SCANTRXTD BASICS ACK: NAME: SCANTRXTD MEASLST: measureList OBJLST: objectList GRANP: granularityPeriod A30808-X3247-L230-3-7619 1221 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get SCANTRXTD BASICS:NAME=SCANTRXTD:0; GET SCANTRXTD STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRXTD GET SCANTRXTD STAT Applicability: Phase 2 Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the BTSM object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "scantdn" can be found in Appendix A. System Responses: REPMETHD: scannerReportMethod START: startDate STOP: stopDate RECINT: recordingInterval LSUPDTIME: lastUpdTime LSLOTIME: lastLockTime LSULOTIME: lastUnlockTime GET SCANTRXTD BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. GET SCANTRXTD STAT: NAME=SCANTRXTD:scantdn; GET SCANTRXTD STAT ACK: GET SCANTRXTD STAT NACK: 1222 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get SCANTRXTD STAT:NAME=SCANTRXTD:0; LOCK SCANTRXTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRXTD LOCK SCANTRXTD Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock SCANTRXTD:NAME=SCANTRXTD:0; NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. LOCK SCANTRXTD: NAME=SCANTRXTD:scantdn; LOCK SCANTRXTD ACK: LOCK SCANTRXTD NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. A30808-X3247-L230-3-7619 1223 Commands Base Station Controller CML:BSC REMOVE SCANTRXTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRXTD REMOVE SCANT- RXTD Applicability: Phase 2. Visibility level 2. Command Description: This command allows to remove objects fromthe the list of objects of the original config- uration of a scanner previously created by the user. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Remove SCANTRXTD:NAME=SCANTRXTD:0,MEASOBJLST=2-0-0&2-0-1&2-0-2&3- 0-0&3-0-1&3-0-2; SET SCANTRXTD REMOVE SCANTRXTD: NAME=SCANTRXTD:scantdn, MEASOBJLST=; REMOVE ACK: Successful REMOVE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the instance of the managed object is in LOCKED state. UNSUCCESSFUL_LIST_OF_OBJECT The object in objlist is not present in database or only one object in the allowed ranges of values. UNSUCCESSFUL_MEMORY_CORRUPTED Memory not available. SET SCANTRXTD: NAME=SCANTRXTD:scantdn [,OBJLST=] [,GRANP=] [,START=] [,STOP=] [,RECINT=]; 1224 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRXTD SET SCANTRXTD Applicability: Phase 2. Visibility level 2. Command Description: This command changes the configuration for an instance of SCANTRXTD scanner object previously created by the user. The parameter specify the values for the sched- uling and reporting activities. The validity range of the object address "scantdn" can be found in Appendix A. System Responses: SET ACK: DBA -> LMT_LOCAL *** RESPONSE TO JOB 1 *** Set Ack SCANTRXTD: name = SCANTRXTD:<istn> commandResponse = SUCCESSFUL SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. UNSUCCESSFUL_INVALID_STATUS The measurements have to be applied to already equipped object instances; after the creation of the object the ADMINISTRATIVE state is UNLOCKED UNSUCCESSFUL_MEAS_ALREADY_PRESENT The same measure and the same object has been already configured in another scanner. UNSUCCESSFUL_LIST_OF_OBJECT The object list contains the same object more times. UNSUCCESSFUL_INVALID_DATE The start date or the stop date are incorrect. UNSUCCESSFUL_TIMEFRAME_INCORRECT The scheduling stop date has to be equal or greater than start date. At least one day within START and STOP dates should be given a period in a weekly RECINT. UNSUCCESSFUL_TIMEFRAME_ELAPSED The scheduling stop date has to be equal or greater than current date. UNSUCCESSFUL_WRONG_RECORDING_DURATION Recording period is not multiple of granularity or RECINT=weekly() and every daily schedulation is none. UNSUCCESSFUL_WRONG_RECORDING_START The period_start_min of every periodDuration must be a multiple of granu- larity. A30808-X3247-L230-3-7619 1225 Commands Base Station Controller CML:BSC Application Guidelines: When a Restart of BSC is done, the Perfomance Measurements Data collected in the lastgranularity are not signicant. PM generation report follows the next rules: Reports contain only equipped objects counters. If all objects under measure are not equipped, a report with objects number equal to zero is always generated. Availability status is ON_DUTY if and only if scanner is unlocked and current time is within schedulation period. Example of Command Execution Set SCANTRXTD:NAME=SCANTRXTD:0,OBJLST=selectObject(0-0-0&0-0-1&0-0- 2),GRANP=MINUTES_5,START=1-Jan-2003,STOP=1-Mar-2003,RECINT=daily(5-0- 6-0); UNLOCK SCANTRXTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRXTD UNLOCK SCANTRXTD Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "scantdn" can be found in Appendix A. System Responses: UNSUCCESSFUL_WRONG_RECORDING_PERIOD Invalid period in RECINT: (start time must be before stop time). UNSUCCESSFUL_RECORDING_OVERLAPPED Periods must not overlap. UNLOCK SCANTRXTD: NAME=SCANTRXTD:scantdn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The instance of the managed object must be already created. 1226 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Unlock SCANTRXTD:NAME=SCANTRXTD:0; A30808-X3247-L230-3-7619 1227 Commands Base Station Controller CML:BSC SOFTWARE-MANAGEMENT The SOFTWARE-MANAGEMENT object provides the functionality to execute BSS software management and to administrate the BSC file system. DNLFILE Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT DNLFILE Applicability: Phase 2. Visibility level 2. Command Description: This command allows the user to transfer a Data file from the LMT disk to a directory in the BSC disk. If the directory specified in the command does not exist, it is automatically created. System Responses: DNLFILE: SRCPATH=, DESTDIR=, OVERWRITE=; DNLFILE ACK: The LMT notifies the percentage of downloaded files in steps of 5% (on the "info line") and the successful completion of the procedure. DNLFILE Download NACK: Possible errors, causing the procedure to abort, notified by the LMT are: File Not Found Message Out Of Sequence Aborted By User Time Out Expired Aborted By Network Element File Too Long For Zero Window Size Disk Access Error User Abort Refused Internal SW Error Segment Out Of Sequence Last Segment Expected Disk Write Error Disk Error Crosscopy In Progress (DK40) Invalid SVR File Already Exists Wrong Destination Path 1228 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: If the download of a DATA file is required, the source pathname has to be specified. The download of a file should not be performed while another file system operation, involving that file, is in progress, even when required by the RC. Such operation could be: move, copy, delete, network element download, Upload. Example of Command Execution DNLFILE:SRCPATH=D:\Siemens\Fw\MPCC.FWI, DESTDIR=FIRMWARE, OVERWRITE=YES; LOADMPCC Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT LOADMPCC Applicability: Phase 1. Visibility level 1. Command Description: This command is the only one available when the LMT BSC is in Phase 1, that is when the MPCC is running in Firmware. This command loads the software fromLMT disk into the MPCCinternal memory. When the command is completed, the MPCC is running in software. System Responses: Possible errors, causing the procedure to abort, notified by the download task on MPCC and displayed by the LMT are: STRING_TOO_LONG A non-terminated string is present in a message field. INVALID_PARAMETER_NCK A message parameter is syntactically incorrect or two message parameters are conflicting. RTE Failure The download task could not obtain an Operating System service. File System Failed The download task could not obtain a File System service. File Present The user requested an unforced download of a file already stored in the destination directory. LOADMPCC: SRCPATH=, SOURCE=; LOADMPCC NACK: NACK CAUSES: NOT MPCC FILE A30808-X3247-L230-3-7619 1229 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution LOADMPCC:SRCPATH="C:\Load\hb0114zz.swl",SOURCE=LMT; UPLBTSLOG Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT UPLBTSLOG Applicability: Phase 2. Visibility level 1. Command Description: This command allows to upload a BTSE log file. System Responses: ABS CRC ERROR TIMEOUT ERROR MSG SEQUENCE ERROR UPLBTSLOG: INSTANCE=,DESTDIR=,FILE=,FILETYPE=,OVERWRITE=; UPLBTSLOG ACK: The LMT notifies the successful completion of the procedure. UPLBTSLOG NACK: NACK CAUSES: Message Out Of Sequence Aborted By Network Element Aborted By User Disk Error File Already Exists Could not Open Destination File Wrong Packet Number Last segment expected Resource Not Available Invalid File Type File Not Available At Destination File In Use Updating of Flash In Progress 1230 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: Only an upload at the time on a specific network element is allowed. Example of Command Execution UPLBTSLOG:INSTANCE=23,DESTDIR=D:\Siemens\Btslogdir, FILE=Bts-23.log,FILETYPE=ALARM_BUFFER,OVERWRITE=YES; UPLBTSTDLOG Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT UPLBTSTDLOG Applicability: Phase 2. Visibility level 1. Command Description: This command allows to upload a BTSTD log file. System Responses: Message Cannot be Performed File System Error Object not equipped. UPLBTSLOG: INSTANCE=,DESTDIR=,FILE=,FILETYPE=,OVERWRITE=; UPLBTSTDLOG ACK: The LMT notifies the successful completion of the procedure. UPLBTSTDLOG NACK: NACK CAUSES: Message Out Of Sequence Aborted By Network Element Aborted By User Disk Error File Already Exists Could not Open Destination File Wrong Packet Number Last segment expected Resource Not Available Invalid File Type File Not Available At Destination File In Use Updating of Flash In Progress A30808-X3247-L230-3-7619 1231 Commands Base Station Controller CML:BSC Application Guidelines: Only an upload at the time on a specific network element is allowed. Example of Command Execution UPLBTSTDLOG:INSTANCE=23,DESTDIR=D:\Siemens\Btslogdir, FILE=Bts-23.log,FILETYPE=ALARM_BUFFER,OVERWRITE=YES; UPLFILE Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT UPLFILE Applicability: Phase 2. Visibility level 2. Command Description: This command allows to transfer a file froma directory of the BSC disk to the LMT disk. The file must be a Data file (e.g. database, measures, BSC log file...). This command is also used to transfer the BSC log file stored in the BSC disk directory LOG. System Responses: Message Cannot be Performed File System Error Object not equipped UPLFILE: DESTDIR=, FILE=, SRCDIR=, OVERWRITE=; UPLFILE ACK: The LMT notifies the successful completion of the procedure. force NOT_FORCED source file DBFILE.DBA dir. name SYS_BACKUP dest. file DBFILE_UPL.DBA UPLFILE NACK: NACK CAUSES: File Not Found Message Out Of Sequence Aborted By User Time Out Expired Aborted By Network Element Internal SW Error Segment Out Of Sequence 1232 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: The upload of a file should not be performed while another file system operation, involving that file, is in progress, even when required by the RC. Such operation could be: move, copy, delete, download. Example of Command Execution UPLFILE:DESTDIR=D:\Siemens\UploadDir\, FILE=MPCC.FWI, SRCDIR=FIRMWARE, OVERWRITE=YES; UPLTRAULOG Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT UPLTRAULOG Applicability: Phase 2. Visibility level 1. Command Description: This command allows to upload a TRAU log file. System Responses: Last Segment Expected Disk Access Error Disk Write Error Disk Error File Already Exists UPLTRAULOG: INSTANCE=, DESTDIR=, FILE=, FILETYPE=, OVERWRITE=; UPLTRAULOG ACK: The LMT notifies the successful completion of the procedure. UPLTRAULOGNACK: NACK CAUSES: Message Out Of Sequence Aborted By Network Element Aborted By User Disk Error File Already Exists Could not Open Destination File Wrong Packet Number Last segment expected Resource Not Available Invalid File Type File Not Available At Destination A30808-X3247-L230-3-7619 1233 Commands Base Station Controller CML:BSC Application Guidelines: Only an upload at the time on a specific network element is allowed. Example of Command Execution UPLTRAULOG:INSTANCE=23,DESTDIR=D:\Siemens\Traulogdir, FILE=Bts-23.log,FILETYPE=ALARM_BUFFER,OVERWRITE=YES; File In Use Updating of Flash In Progress Message Cannot be Performed File System Error Object not equipped 1234 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SS7L The SS7L object represents an SS7 link. CREATE SS7L Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SS7L CREATE SS7L Applicability: Phase 2. Visibility level 2. Command Description: This command adds a SS7 signalling link to the system specifying the PPCC card number and the circuit number which it has to be connected to. The validity range of the object address "ss7ln" can be found in Appendix A. System Responses: CREATE SS7L: NAME=SS7L:ss7ln [,LNKA= ],TSLA= ,SLC= ,LKSET= ; CREATE ACK: Successful CREATE NACK: NACK CAUSES: SUPERORDINATE_NOTEQUIPPED The OPC object instance must be already equipped. The relevant PCM line used for the link must be already equipped. OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_TIME_SLOT_ALREADY_ALLOCATED The timeslot "timeslotn" of all the pcma lines (or of the pcms line) connected to the TRAU has not to be already reserved in order to submit the CREATE SS7L command. The selected TSLA is already carrying a NUC. UNSUCCESSFUL_LINK_CONNECTED The circuit of PPCC ("circuitn") has not to be already connected in order to submit the command. UNSUCCESSFUL_INVALID_ATTRIBUTES The value assigned to the SLC attribute is already used by another SS7L equipped in the BSC. A30808-X3247-L230-3-7619 1235 Commands Base Station Controller CML:BSC Application Guidelines: After the creation of the object, the ADMINISTRATIVE state of this object is set at LOCKED. An UNLOCK command is required to put this object in service. Example of Command Execution Create SS7L:NAME=SS7L:0,LNKA=0-0,TSLA=0-2,SLC=10,LKSET=0; DELETE SS7L Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SS7L DELETE SS7L Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a SS7 signalling link previously created through the CREATE SS7L command. The validity range of the object address "ss7ln" can be found in Appendix A. System Responses: The LNKA attribute must be equal to NULL if the network card is NTWSNAP or NTWSNAP_STLP, whereas when the network card is NTWSN16 this attribute must necessarily have a value different from NULL. UNSUCCESSFUL_INVALID_TIME_SLOT The value assigned to the tslan field of the TSLA attribute is not compatible with the PCM line type attribute (parameter PCMTYPE of BSC object). UNSUCCESSFUL_INVALID_STATUS The command can be performed only if the TRAU object instance is in LOCKED state. UNSUCCESSFUL_LINKSET_ONE_CONNECTED The rst instance of the SS7L object must be created on linkset 0. No instances of SS7L object can be created on linkset 1 if the SMLCSPC of OPC object is not congured. DELETE SS7L: NAME=SS7L:ss7ln; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1236 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Delete SS7L:NAME=SS7L:0; GET SS7L Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SS7L GET SS7L Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve information about a SS7 signalling link previously created through the CREATE SS7L command. The validity range of the object address "ss7ln" can be found in Appendix A. System Responses: UNSUCCESSFUL_INVALID_STATUS Before deleting a SS7L, the relative object instance must be in LOCKED state. Before deleting a SS7L, the related TRAU object instance must be in LOCKED state. UNSUCCESSFUL_LINKSET_ONE_CONNECTED The SS7L object cannot be deleted with linkset 0 if a SS7L with linkset 1 exists. GET SS7L: NAME=SS7L:ss7ln [,REQATTL= LNKA, TSLA, SLC, TOPOREL, LKSET]; GET ACK: NAME: name LNKA: lnka PPCCN: ppccNumber CIRCN: circNumber TSLA: tsla PCMAN: pcmaNumber TSLAN: tslaNumber SLC: SignallingLinkCode LKSET: linkset GET NACK: A30808-X3247-L230-3-7619 1237 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get SS7L:NAME=SS7L:0,REQATTL=LNKA&TSLA&SLC&TOPOREL&LKSET; GET SS7L BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SS7L GET SS7L BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "ss7ln" can be found in Appendix A. System Responses: Application Guidelines: None. NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SS7L BASICS: NAME=SS7L:ss7ln; GET SS7L BASICS ACK: NAME: name LNKA: lnka PPCCN: ppccNumber CIRCN: circNumber TSLA: tsla PCMAN: pcmaNumber TSLAN: tslaNumber SLC: SignallingLinkCode LKSET: linkset GET SS7L BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1238 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Get SS7L BASICS:NAME=SS7L:0; GET SS7L STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SS7L GET SS7L STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SS7L object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK) S7 Status. The validity range of the object address "ss7ln" can be found in Appendix A. System Responses: Application Guidelines: 1. Only sets with raised bits are shown. 2. If, after an MPCC switch, the SS7 link stays in restoring state, a GET SS7L STAT command has to be performed. If in the result of the previous command adjacent SP status is equal to MTP_ACCESSIBLE, it is necessary to make lock and unlock of the SS7L in order to synchronize the state. Example of Command Execution Get SS7L STAT:NAME=SS7L:1; GET SS7L STAT: NAME=SS7L:ss7ln; GET SS7L STAT ACK: GET SS7L STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1239 Commands Base Station Controller CML:BSC GETRELATIONSHIP SS7L Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SS7L GETRELATIONSHIP SS7L Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of all the HMOs (Hardware Managed Object) supporting the FMO functionality. For the SS7L object the related HMOs are the following: PPCC, PWRD, MPCC, TDPC, MEMT, NTW and PPXL. The validity range of the object address "ss7ln" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship SS7L:NAME=SS7L:0; GETSUBO SS7L Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SS7L GETSUBO SS7L Applicability: Phase 2. Visibility level 0. GETRELATIONSHIP SS7L: NAME=SS7L:ss7ln; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. GETSUBO SS7L: NAME=SS7L:ss7ln;; 1240 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "ss7ln" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo SS7L:NAME=SS7L:0; INHIBIT SS7L Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SS7L INHIBIT SS7L Applicability: Phase 2. Visibility level 1. Command Description: This command allows the inhibition of a SS7 link. The validity range of the object address "ss7ln" can be found in Appendix A. System Responses: GETSUBO SS7L ACK: The output of the command can be composed by one or more packs with a maximum number of ten subordinated mnemonics; at the end there a message is displayed noti- fying the end of the subordinate list. GETSUBO SS7L NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. INHIBIT SS7L: NAME=SS7L:ss7ln; INHIBIT ALLOWED: <object_id> It means that the system has properly checked and inhibited the link specified in the <object_id> field. INHIBIT DENIED: <object_id>, <cause> It indicates that the inhibition of the link is not possible. The meaning of the information fields within the arrowbrackets is as follows: A30808-X3247-L230-3-7619 1241 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Inhibit SS7L:NAME=SS7L:0; LOCK SS7L Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SS7L LOCK SS7L Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state "Locked". The validity range of the object address "ss7ln" can be found in Appendix A. System Responses: <object_id> It indicates the link where the inhibition procedure is executed and has the following format: SS7L-ss7ln where ss7ln can assume the values 0 to 15. cause It indicates where the inhibition has been rejected and can assume the following values: LOCAL: It means that the link cannot be inhibited locally. REMOTE: It means that the link cannot be inhibited at the remote end. LOCK SS7L: NAME=SS7L:ss7ln; LOCK SS7L ACK: LOCK SS7L NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1242 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. If object TRX or CHAN is locked, calls using the concerned objects are dropped. To avoid loss of calls by locking objects TRX or CHAN a request for usage state of this objects should be done previously (e.g. GET state status). In case returned usage state is "active" or "busy" locking should not be done (otherwise calls are dropped). 2. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 3. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock SS7L:NAME=SS7L:0; TESTLINK SS7L Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SS7L TESTLINK SS7L Applicability: Phase 2. Visibility level 1. Command Description: This command allows to diagnose a SS7 link to verify the correct message exchange between signalling points. The validity range of the object address "ss7ln" can be found in Appendix A. System Responses: STANDBY_PLLH_DAC_WORD_EVOLVING It is emitted when the PLLH has become synchronized to an external source little time ago, and the switch of the master PLLH (for LOCK or SWITCH command) would leave the frequency of the new active PLLH with a bad value; it can be answered up to 5 minutes after a SYNC or SYNE has gone PROVIDING SERVICE. The same can happen if less than 5 minutes have passed since last switch of NTW. TESTLINK SS7L: NAME=SS7L:ss7ln; TEST LINK PASSED: <object_id>, <cause> It indicates that the test was unsuccessful. The meaning of the information fields within the arrowbrackets is the following: A30808-X3247-L230-3-7619 1243 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Testlink SS7L:NAME=SS7L:0; UNINHIBIT SS7L Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SS7L UNINHIBIT SS7L Applicability: Phase 2. Visibility level 1. Command Description: This command allows the uninhibited of a SS7 link. The validity range of the object address "ss7ln" can be found in Appendix A. System Responses: object_id It indicates the link where the test procedure is executed and has the following format: SS7L-ss7ln where ss7ln can assume values from 0 to 15. cause It indicates the reason why the test failed and can assume the following values: WRONG PATTERN: It means that the acknowledgment MSU sent from the remote end has the wrong test pattern. TIMER EXPIRED: It means that the acknowledgment MSU did not arrive in the specified time. UNINHIBIT SS7L: NAME=SS7L:ss7ln; UNINHIBIT ALLOWED: <object_id> It means that the systemhas properly checked and uninhibited the link specified in the <object_id> field. UNINHIBIT DENIED: <object_id>, <cause> It indicates that the link must remain inhibited. The meaning of the information fields within the arrowbrackets is as follows: <object_id> It indicates the link where the uninhibited procedure is executed and has the following format: SS7L-ss7ln where ss7ln can assume the values from 0 to 15. cause indicates whether the refusal of the request is local or remote and can assume the following values: 1244 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Uninhibit SS7L:NAME=SS7L:0; UNLOCK SS7L Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SS7L UNLOCK SS7L Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state "Unlocked". The validity range of the object address "ss7ln" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock SS7L:NAME=SS7L:0; LOCAL: It means that the link cannot be uninhibited for local causes. REMOTE: It means that the link cannot be uninhibited for remote causes. UNLOCK SS7L: NAME=SS7L:ss7ln; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1245 Commands Base Station Controller CML:BSC SS7S The SS7S object summarizes the operational state of all the SS7L objects. It is enabled if all the SS7L objects are enabled. GET SS7S STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SS7S GET SS7S STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SS7S object: Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK) S7 Status. The validity range of the object address "ss7sn" can be found in Appendix A. System Responses: Application Guidelines: Only sets with raised bits are shown. Example of Command Execution Get SS7S STAT:NAME=SS7S:0; GET SS7S STAT: NAME=SS7S:ss7sn; GET SS7S STAT ACK: GET SS7S STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1246 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETSUBO SS7S Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SS7S GETSUBO SS7S Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "ss7sn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo SS7S:NAME=SS7S:0; GETSUBO SS7S: NAME=SS7S:ss7sn; GETSUBO SS7S ACK: The output of the command can be composed by one or more packs with a maximum number of ten subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GETSUBO SS7S NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1247 Commands Base Station Controller CML:BSC SUBTSLB The SUBTSLB object provides the functionality of the 16 kbit/s subslots on the Abis interface. Each 16 kbit/s subslot (SUBTSLB instance) is associated to a LAPD channel (LPDLM instance). The set of 16 kbit/s subslots (SUBTSLB instances) reserved to a BTSM for traffic services is called Abis pool. In case of BTS supporting dynamic Abis allocation, Abis subslots are selected from the pool and allocated to radio channels at channel activation. In case of BTS supporting static Abis allocation, Abis subslots are selected from the pool and allocated to radio channels by O&M procedures. An Abis pool is available to all BTSM radio channels and is composed of one or more Abis subpools. An Abis subpool is a set of 16 kbit/s Abis subslots, belonging to a single PCM line, routed together with the associated LPDLM instance on the same PCM line (see below). CREATE SUBTSLB Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMB TSLB SUBTSLB CREATE SUBTSLB Applicability: Phase 2. Visibility level 2. Command Description: This command creates an instance of the SUBTSLB object. By means of the ASSLAPD attribute, the SUBTSLB object instance is associated to a LPDLM/LPDLMTD object instance. Validity ranges of the object addresses "tslbn" and subtslbn can be found in Appendix A. System Responses: CREATE SUBTSLB: NAME=PCMB:pcmbn/TSLB:tslbn/SUBTSLB:subtslbn ,ASSLAPD=; CREATE ACK: Successful CREATE NACK: NACK CAUSES: OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The PCMB object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The associated Lapd must be an equipped LPDLM or LPDLMTD. 1248 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Create SUBTSLB:NAME=PCMB:0/TSLB:1/SUBTSLB:0, ASSLAPD=BTSM:0/LPDLM:0; DELETE SUBTSLB Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMB TSLB SUBTSLB DELETE SUBTSLB Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a SUBTSLB object instance previously created through the CREATE SUBTSLB command. Validity ranges of the object addresses "tslbn" and subtslbn can be found in Appendix A. System Responses: The SUBTSLB object and the associated Lapd must belong to the same PCMB. UNSUCCESSFUL_INVALID_TIME_SLOT The value assigned to the timeslot number must be compatible with the PCM line type (PCM24 or PCM30). UNSUCCESSFUL_TIME_SLOT_ALREADY_ALLOCATED The selected PCMB timeslot must not be already equipped because of the presence of an L1CTS, LPDLM, LPDLMTD or NUC. UNSUCCESSFUL_SUB_SLOT_ALREADY_ALLOCATED If two PCMBs connected to the same port exist, it is not possible to create two SUBTSLBs having the same address on those PCMBs. DELETE SUBTSLB: NAME=PCMB:pcmbn/TSLB:tslbn/SUBTSLB:subtslbn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1249 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Delete SUBTSLB:NAME=PCMB:0/TSLB:1/SUBTSLB:0; GET SUBTSLB Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMB TSLB SUBTSLB GET SUBTSLB Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve information about a SUBTSLB previously created through the CREATE SUBTSLB command. Validity ranges of the object addresses "tslbn" and subtslbn can be found in Appendix A. System Responses: Application Guidelines: None. UNSUCCESSFUL_INVALID_STATUS Before deleting a SUBTSLB, the relative object instance must be in LOCKED state. UNSUCCESSFUL_LINK_CONNECTED If the SWVersion running on the superordinate BTSM belongs to BR6.0 release (see EXPSWV parameter description), that is Abis allocation is static, the command is accepted only if no CHAN is statically associated to that SUBTSLB. GET SUBTSLB: NAME=PCMB:pcmbn/TSLB:tslbn/SUBTSLB:subtslbn [,REQATTL= ASSLAPD]; GET ACK: NAME: name ASSLAPD: associatedLapd GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1250 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Get SUBTSLB:NAME=PCMB:0/TSLB:1/SUBTSLB:0,REQATTL=ASSLAPD; GET SUBTSLB BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMB TSLB SUBTSLB GET SUBTSLB BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses "tslbn" and subtslbn can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SUBTSLB BASICS:NAME=PCMB:0/TSLB:1/SUBTSLB:0; GET SUBTSLB STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMB TSLB SUBTSLB GET SUBTSLB STAT GET SUBTSLB BASICS: NAME=PCMB:pcmbn/TSLB:tslbn/SUBTSLB:subtslbn; GET SUBTSLB BASICS ACK: NAME: name ASSLAPD: associatedLapd GET SUBTSLB BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SUBTSLB STAT: NAME=PCMB:pcmbn/TSLB:tslbn/SUBTSLB:subtslbn; A30808-X3247-L230-3-7619 1251 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SUBTSLB object: Administrative State (AST) Operational State (OST) Usage State (UST) Availability Status (AVS). Validity ranges of the object addresses "tslbn" and subtslbn can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SUBTSLB STAT:NAME=PCMB:0/TSLB:1/SUBTSLB:0; LOCK SUBTSLB Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMB TSLB SUBTSLB LOCK SUBTSLB Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state LOCKED. Validity ranges of the object addresses "tslbn" and subtslbn can be found in Appendix A. GET SUBTSLB STAT ACK: GET SUBTSLB STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK SUBTSLB: NAME=PCMB:pcmbn/TSLB:tslbn/SUBTSLB:subtslbn; 1252 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Lock SUBTSLB:NAME=PCMB:0/TSLB:1/SUBTSLB:0; SHUTDOWN SUBTSLB Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMB TSLB SUBTSLB SHUTDOWN SUBTSLB Applicability: Phase 2. Visibility level 2. Command Description: This command allows the graceful transition of a SUBTSLB object instance from the administrative state UNLOCKED to the administrative state LOCKED after the object has terminated its current activity. After a SHUTDOWN SUBTSLB command, the system tries for 5 minutes the handover of circuit switched services. If the handover is unsuccessful, the call is dropped. The behaviour for packet switched services is the same as in LOCK case. Validity ranges of the object addresses "tslbn" and "subtslbn" can be found in Appendix A. System Responses: Application Guidelines: None. LOCK SUBTSLB ACK: LOCK SUBTSLB NACK: NACK CAUSES: SHUTDOWN SUBTSLB: NAME=PCMB:pcmbn/TSLB:tslbn/SUBTSLB:subtslbn; SHUTDOWN SUBTSLB ACK: SHUTDOWN SUBTSLB NACK: NACK CAUSES: A30808-X3247-L230-3-7619 1253 Commands Base Station Controller CML:BSC Example of Command Execution Shutdown SUBTSLB:NAME=PCMB:0/TSLB:1/SUBTSLB:0; UNLOCK SUBTSLB Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMB TSLB SUBTSLB UNLOCK SUBTSLB Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object at the administrative state UNLOCKED. Validity ranges of the object addresses "tslbn" and subtslbn can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock SUBTSLB:NAME=PCMB:0/TSLB:1/SUBTSLB:0; UNLOCK SUBTSLB: NAME=PCMB:pcmbn/TSLB:tslbn/SUBTSLB:subtslbn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: 1254 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SWIBEAM The SWIBEAM object represents the switched beam functionality. CREATE SWIBEAM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SWIBEAM CREATE SWIBEAM Applicability: Phase 2. Visibility level 2. Command Description: This command creates an instance of the SWIBEAM object. The validity range of the object address swibeamn can be found in Appendix A. System Responses: i At present the SWIBEAM feature can be enabled only via patch for field testing purposes. CREATE SWIBEAM: NAME=BTSM:btsmn/BTS:btsn/SWIBEAM:swibeamn [,ENSWBCS=] [,RXSRS=] [,RXTO=] [,RUNAVGFCTSUBS=] [,RXTH=] [,RXMSUBS=] [,RXDLTSUBS=] [,STATSUBS=] [,NORTSUBS=] [,PTSUBS=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: FEATURE_NOT_RELEASED The feature is not supported by current software loading version. OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The BTS object instance must be already equipped. INCOMP_NESWLOAD_VS_MESSAGE The superordinate BTSM is not of type BTSplus. The SWIBEAMis not supported if the SWVersion running on the superordinate BTSM object belongs to BR6.0 release (see EXPSWV parameter description). A30808-X3247-L230-3-7619 1255 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Create SWIBEAM:NAME=BTSM:0/BTS:1/SWIBEAM:0,ENSWBCS=TRUE, RXSRS=PERIODICAL,RXTO=TDMA_FRAMES_2, RUNAVGFCTSUBS=RUNAVG_05,RXTH=MDB_110,RXMSUBS=4, RXDLTSUBS=RXD_15,STATSUBS=2,NORTSUBS=10,PTSUBS=4; DELETE SWIBEAM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SWIBEAM DELETE SWIBEAM Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a SWIBEAM object instance previously created through the CREATE SWIBEAM command. The validity range of the object address "swibeamn can be found in Appendix A. System Responses: UNSUCCESSFUL_INVALID_ATTRIBUTES The superordinate BTS has been configured as multiband cell, that is with one of the following SYSID values: GSM850PCS, GSMDCS, EXT900, GSM850DCS. Switching beam and multiband cell are mutually exclusive. The ETXDIVTS attribute (see BTS object) is set at TRUE. The superordinate BTS has been configured as extended cell (CELLTYPE = EXTCELL). Switching beam and extended cell are mutually exclusive. DELETE SWIBEAM: NAME=BTSM:btsmn/BTS:btsn/SWIBEAM:swibeamn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: FEATURE_NOT_RELEASED The feature is not supported by current software loading version. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1256 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Delete SWIBEAM:NAME=BTSM:0/BTS:1/SWIBEAM:0; GET SWIBEAM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SWIBEAM GET SWIBEAM Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve information about a SWIBEAM previously created through the CREATE SWIBEAM command. The validity range of the object address "swibeamn can be found in Appendix A. System Responses: GET SWIBEAM: NAME=BTSM:btsmn/BTS:btsn/SWIBEAM:swibeamn [,REQATTL= ENSWBCS, RXSRS, RXTO, RUNAVGFCTSUBS, RXTH, RXMSUBS, RXDLTSUBS, STATSUBS, NORTSUBS, PTSUBS]; GET ACK: NAME: name ENSWBCS: enableSwitchedBeamCS RXSRS: rxSwitchRequiredSetting RXTO: rxToggleFrequency RUNAVGFCTSUBS: runAvrgFactSubsec RXTH: rxThresholdTXDirection RXMSUBS: rxMarginSubsec RXDLTSUBS: rxDeltaSubsec STATSUBS: startTimerSubsec NORTSUBS: noRXTimerSubsec PTSUBS: penaltyTimerSubsec GET NACK: NACK CAUSES: A30808-X3247-L230-3-7619 1257 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get SWIBEAM:NAME=BTSM:0/BTS:1/SWIBEAM:0,REQATTL=ENSWBCS& RXSRS&RXTO&RUNAVGFCTSUBS&RXTH&RXMSUBS&RXDLTSUBS& STATSUBS&NORTSUBS&PTSUBS; GET SWIBEAM BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SWIBEAM GET SWIBEAM BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "swibeamn can be found in Appendix A. System Responses: FEATURE_NOT_RELEASED The feature is not supported by current software loading version. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SWIBEAM BASICS: NAME=BTSM:btsmn/BTS:btsn/SWIBEAM:swibeamn; GET SWIBEAM BASICS ACK: NAME: name ENSWBCS: enableSwitchedBeamCS RXSRS: rxSwitchRequiredSetting RXTO: rxToggleFrequency RUNAVGFCTSUBS: runAvrgFactSubsec RXTH: rxThresholdTXDirection RXMSUBS: rxMarginSubsec RXDLTSUBS: rxDeltaSubsec STATSUBS: startTimerSubsec NORTSUBS: noRXTimerSubsec PTSUBS: penaltyTimerSubsec GET SWIBEAM BASICS NACK: 1258 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get SWIBEAM BASICS:NAME=BTSM:0/BTS:1/SWIBEAM:0; GET SWIBEAM CSSERV Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SWIBEAM GET SWIBEAM CSSERV Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the CSSERV group. The validity range of the object address "swibeamn can be found in Appendix A. System Responses: NACK CAUSES: FEATURE_NOT_RELEASED The feature is not supported by current software loading version. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SWIBEAM CSSERV: NAME=BTSM:btsmn/BTS:btsn/SWIBEAM:swibeamn; GET SWIBEAM CSSERV ACK: NAME: name ENSWBCS: enableSwitchedBeamCS RXSRS: rxSwitchRequiredSetting RXTO: rxToggleFrequency RUNAVGFCTSUBS: runAvrgFactSubsec RXTH: rxThresholdTXDirection RXMSUBS: rxMarginSubsec RXDLTSUBS: rxDeltaSubsec STATSUBS: startTimerSubsec NORTSUBS: noRXTimerSubsec PTSUBS: penaltyTimerSubsec GET SWIBEAM CSSERV NACK: NACK CAUSES: A30808-X3247-L230-3-7619 1259 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get SWIBEAM CSSERV:NAME=BTSM:0/BTS:1/SWIBEAM:0; SET SWIBEAM Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SWIBEAM SET SWIBEAM Applicability: Phase 2. Visibility level 2. Command Description: This command modifies the attributes of a SWIBEAMobject previously created through the CREATE SWIBEAM command. The validity range of the object address "swibeamn can be found in Appendix A. System Responses: Application Guidelines: None. FEATURE_NOT_RELEASED The feature is not supported by current software loading version. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SET SWIBEAM: NAME=BTSM:btsmn/BTS:btsn/SWIBEAM:swibeamn [,ENSWBCS=] [,RXSRS=] [,RXTO=] [,RUNAVGFCTSUBS=] [,RXTH=] [,RXMSUBS=] [,RXDLTSUBS=] [,STATSUBS=] [,NORTSUBS=] [,PTSUBS=]; SET ACK: Successful SET NACK: NACK CAUSES: FEATURE_NOT_RELEASED The feature is not supported by current software loading version. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1260 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Set SWIBEAM:NAME=BTSM:0/BTS:1/SWIBEAM:0,ENSWBCS=TRUE, RXSRS=PERIODICAL,RXTO=TDMA_FRAMES_2, RUNAVGFCTSUBS=RUNAVG_05,RXTH=MDB_110,RXMSUBS=4, RXDLTSUBS=RXD_15,STATSUBS=2,NORTSUBS=10,PTSUBS=4; A30808-X3247-L230-3-7619 1261 Commands Base Station Controller CML:BSC SYNC The SYNC object is the synchronization source which arrives to the BSC Network Clock from the MSC, via A interface - TRAU - Asub interface. CREATE SYNC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SYNC CREATE SYNC Applicability: Phase 2. Visibility level 2. Command Description: This command adds a clock synchronization signal (SYNC) to the system. The synchronization signal is derived fromthe 2048 kbit/s signal of the given PCMS line (PCM line on the "Asub" interface). The validity range of the object address "syncn" can be found in Appendix A. This field identifies the priority too; the value zero is associated with the highest priority. System Responses: Application Guidelines: 1. This synchronization source has lower priority than SYNE synchronization source. 2. After the creation of the object the ADMINISTRATIVE state of this object is set at LOCKED. The UNLOCK command is required to put this object in service. 3. In case of failure at PCM-Line, selected by TRAU as synchronization line, TRAU selects a different line not before one second has expired. Therefore, if BSC detects synchronization problems prior to TRAU, BSC selects a different TRAU (if available) for synchronisation purpose. Example of Command Execution Create SYNC:NAME=SYNC:0,PCMSOBJ=0; CREATE SYNC: NAME=SYNC:syncn ,PCMSOBJ=; CREATE ACK: Successful CREATE NACK: NACK CAUSES: OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. SUPERORDINATE_NOTEQUIPPED The relevant TRAU attached to the PCMS line must be already equipped. 1262 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DELETE SYNC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SYNC DELETE SYNC Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a Synchronization Source (SYNC) previously created through the CREATE SYNC command. The validity range of the object address "syncn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete SYNC:NAME=SYNC:0; GET SYNC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SYNC GET SYNC Applicability: Phase 2. Visibility level 1. DELETE SYNC: NAME=SYNC:syncn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a SYNC, the relative object instance must be in LOCKED state. GET SYNC: NAME=SYNC:syncn [,REQATTL=PCMSOBJ]; A30808-X3247-L230-3-7619 1263 Commands Base Station Controller CML:BSC Command Description: This command is used to retrieve the parameters relevant to the clock synchronization signal. The validity range of the object address "syncn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get SYNC:NAME=SYNC:0,REQATTL=PCMSOBJ; GET SYNC BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SYNC GET SYNC BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "syncn" can be found in Appendix A. System Responses: GET ACK: NAME: name PCMSOBJ: relatedPcmsObject GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SYNC BASICS: NAME=SYNC:syncn; GET ACK: NAME: name PCMSOBJ: relatedPcmsObject GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1264 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get SYNC BASICS:NAME=SYNC:0; GET SYNC STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SYNC GET SYNC STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SYNC object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Standby Status (STNDBY) Unknown Status (UNK). The validity range of the object address "syncn" can be found in Appendix A. System Responses: Application Guidelines: Only sets with raised bits are shown. Example of Command Execution Get SYNC STAT:NAME=SYNC:0; GET SYNC STAT: NAME=SYNC:syncn; GET SYNC STAT ACK: GET SYNC STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1265 Commands Base Station Controller CML:BSC GETRELATIONSHIP SYNC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SYNC GETRELATIONSHIP SYNC Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of the all HMOs (Hardware Managed Object) supporting the FMO functionality. For the SYNC object the related HMOs are the following: LICD/LICDS, EPWR, PWRD, MPCC, TDPC, MEMT, NTW, BSMS and TPWR. The validity range of the object address "syncn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship SYNC:NAME=SYNC:0; GETSUBO SYNC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SYNC GETSUBO SYNC Applicability: Phase 2. Visibility level 0. GETRELATIONSHIP SYNC: NAME=SYNC:syncn; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The object instance does not provide any relationship attribute. GETSUBO SYNC: NAME=SYNC:syncn; 1266 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command is used to retrieve the list of the direct subordinate objects of a specified object. The validity range of the object address "syncn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo SYNC:NAME=SYNC:0; LOCK SYNC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SYNC LOCK SYNC Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "syncn" can be found in Appendix A. System Responses: GETSUBO SYNC ACK: The output of the command can be composed by one or more packs with a maximum number of ten subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GETSUBO SYNC NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK SYNC: NAME=SYNC:syncn; LOCK SYNC ACK: LOCK SYNC NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. A30808-X3247-L230-3-7619 1267 Commands Base Station Controller CML:BSC Application Guidelines: 1. If object TRX or CHAN is locked, calls using the concerned objects are dropped. To avoid loss of calls by locking objects TRX or CHAN a request for usage state of this objects should be done previously (e.g. GET state status). In case returned usage state is "active" or "busy" locking should not be done (otherwise calls are dropped). 2. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 3. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock SYNC:NAME=SYNC:0; UNLOCK SYNC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SYNC UNLOCK SYNC Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "syncn" can be found in Appendix A. System Responses: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. STANDBY_PLLH_DAC_WORD_EVOLVING It is emitted when the PLLH has become synchronized to an external source little time ago, and the switch of the master PLLH (for LOCK or SWITCH command) would leave the frequency of the new active PLLH with a bad value; it can be answered up to 5 minutes after a SYNC or SYNE has gone PROVIDING SERVICE. The same can happen if less than 5 minutes have passed since last switch of NTW. UNLOCK SYNC: NAME=SYNC:syncn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: 1268 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Unlock SYNC:NAME=SYNC:0; ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1269 Commands Base Station Controller CML:BSC SYNCO The SYNCOobject is the synchronization complex control; it consists of synchronization source equipment and functions. GETINFO SYNCO Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SYNCO GETINFO SYNCO Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The states and the standby status for both NTW copies 2. The version of the PLLH card. 3. The synchronization operation mode. 4. The current frequency. 5. The time elapsed since the synchronization operation mode became SYNCHRONIZED. 6. The TUNE WORD value (frequency stored in the EEPROM) and the DAC word value (frequency present output by the PLLH). 7. The DELTA attribute: a signed value which represents the error ratio between the two frequencies controlled by the two previous attributes TUNE and DAC and dependent from the PLLH version: PLLHV1: DELTA=DAC-TUNE PLLHV2:DELTA=(DAC-TUNE)/5 8. The phase error. 9. The states and statuses of each equipped SYNE: AST, OST, AVS, CST, STNDBYST, PRS. 10. For each equipped SYNC: The states and statuses: AST, OST, AVS, CST, STNDBYST, PRS. The TRAU number. The synchronization source (MSC or BSC). The number of PCMA line taking the synchronization signal (if SYNC source is MSC, else no SYNC source from MSC will be displayed). The line interface card (LICD) number and circuit. The working mode (SINGLE_TRUNK, DOUBLE_TRUNK). The used trunk (TRUNK_A, TRUNK_B). The validity range of the object address "syncon" can be found in Appendix A. System Responses: GETINFO SYNCO ACK: GETINFO SYNCO: NAME=SYNCO:syncon; 1270 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BSC_CONTROLLER -> LMT_LOCAL PC Time&DATE = 05:10:39 25/04/1999 *** RESPONSE TO JOB 1*** Get Info Report Ack SYNCO: name = SYNCO:0 BSC_CONTROLLER -> LMT_LOCAL PC Time&DATE = 05:10:39 25/04/1999 NE Time&Date = 14:19:54 26/04/1999 *** INFORMATION *** GET INFO REPORT SYNCO: NAME = SYNCO:0 NTW 0: ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED STANDBY STATUS: PROVIDING_SERVICE NTW 1: ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED STANDBY STATUS: HOT_STANDBY PLLH NR. PLLH VER. SYNC_MODE FREQ 0 12345678901234567890 ASYNC_ON_TUNE 1 1 523676 SLAVE 3 PLLH NR. ELAPSED_TIME TUNE DAC DELTA PHASE ERROR 0 31-09:55:20 432 4367 53 9 1 06-21:11:03 1 7 9645 1 SYNE 0: ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE STANDBY STATUS: NONE PROCEDURAL STATUS: NONE SYNE 1: A30808-X3247-L230-3-7619 1271 Commands Base Station Controller CML:BSC ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE STANDBY STATUS: NONE PROCEDURAL STATUS: NONE SYNC 0: ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE STANDBY STATUS: PROVIDING_SERVICE PROCEDURAL STATUS: NONE TRAU NR: 1 SYNC SOURCE: MSC SYNC PCMA: 3 LICD CIRCUIT: 9 - 5 (LICD NR - CIRC NR) WORKING MODE: DOUBLE_TRUNK USED TRUNK: TRUNK_A SYNC 1: ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE STANDBY STATUS: HOT_STANDBY PROCEDURAL STATUS: NONE TRAU NR: 2 SYNC SOURCE: FREE_RUNNING SYNC PCMA: 12 LICD CIRCUIT: 9 - 4 (LICD NR - CIRC NR) WORKING MODE: SINGLE_TRUNK USED TRUNK: TRUNK_A ... ... 1272 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SYNC 35: ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CONTROL STATUS: NONE STANDBY STATUS: HOT_STANDBY PROCEDURAL STATUS: NONE TRAU NR: 0 SYNC SOURCE: BSC SYNC PCMA: 6 LICD CIRCUIT: 9 - 1 (LICD NR - CIRC NR) WORKING MODE: DOUBLE_TRUNK USED TRUNK: TRUNK_A END OF REPORT GETINFO SYNC NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack SYNC: name = SYNC:0 nackCause = <nack cause> Application Guidelines: The possible values for the attribute SYNC-MODE can be: SYNC, when the synchronism source is external (SYNC or SYNE). ASYNC_ON_TUNE, when the PLLH generates internally the synchronism from DAC value. SLAVE, when the PLLH receives the synchronism from the other PLLH card. The attributes FREQ, ELAPSED-TIME, PHand ERRrepresent if the PLLHis master and only when the value of the attribute SYNC-MODE is SYNC. Example of Command Execution Getinfo SYNCO:NAME=SYNCO:0; NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another GetInfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 GetInfo commands already in progress. A30808-X3247-L230-3-7619 1273 Commands Base Station Controller CML:BSC SYNE The SYNE object is the external synchronization source which may be connected to the BSC clock by the operator. CREATE SYNE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SYNE CREATE SYNE Applicability: Phase 2. Visibility level 2. Command Description: This command adds an external synchronization signal source (SYNE) to the system. The signal is directly connected to one of the two external input accesses of the PLLH card. The validity range of the object address "synen" can be found in Appendix A. System Responses: Application Guidelines: 1. Before submitting the command the relevant hardware has to be plugged in the proper slot. 2. This synchronization source has higher priority than SYNC synchronization source. 3. After the creation of the object the ADMINISTRATIVE state of this object is set at LOCKED. The UNLOCK command is required to put this object in service. Example of Command Execution Create SYNE:NAME=SYNE:0 CREATE SYNE: NAME=SYNE:synen; CREATE ACK: Successful CREATE NACK: NACK CAUSES: OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. 1274 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DELETE SYNE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SYNE DELETE SYNE Applicability: Phase 2. Visibility level 2. Command Description: This command deletes an external synchronization signal source (SYNE) previously created through the CREATE SYNE command. The validity range of the object address "synen" can be found in Appendix A. System Responses: Application Guidelines: The relevant hardware can be unplugged after submitting the command. Example of Command Execution Delete SYNE:NAME=SYNE:0 FREQMEAS SYNE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SYNE FREQMEAS SYNE Applicability: Phase 2. Visibility level 2. DELETE SYNE: NAME=SYNE:synen; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a SYNE, the relative object instance must be in LOCKED state. FREQMEAS SYNE: NAME=SYNE:synen, DUR=; A30808-X3247-L230-3-7619 1275 Commands Base Station Controller CML:BSC Command Description: This command allows to perform a frequency measurement over a specified syne source and report the measurement performed by the system before having selected a certain source of synchronism. The validity range of the object address "synen" can be found in Appendix A. System Responses: Application Guidelines: A spontaneous message is the normal consequence of this command. The message is MEASSYNESPN with three values associated: K and E that form the frequency error like Kx10-E and the phase error P between this source and the current source of synchronism. Example of Command Execution Freqmeas SYNE:NAME=SYNE:1,DUR=17; GET SYNE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SYNE GET SYNE Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the EQUIPPED state of the external synchronization signal source (SYNE) previously created through the CREATE SYNE command. The validity range of the object address "synen" can be found in Appendix A. FREQMEAS ACK: Successful The command has been accepted; a measurement REPORT will follow or an error will be issued. FREQMEAS NACK: NACK CAUSES: UNSUCCESSFUL_HW_FAILURE Hardware problems during the execution of the command. INVALID_CONDITION_FOR_MEASUREMENT The NTW copy is not in the correct state. The NTW copy that has to perform the command must be UNLOCKED/ENABLED/HOT-STANDBY. GET SYNE: NAME=SYNE:synen; 1276 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Get SYNE:NAME=SYNE:0; GET SYNE STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SYNE GET SYNE STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the SYNE object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Standby Status (STNDBY) Unknown Status (UNK). The validity range of the object address "synen" can be found in Appendix A. System Responses: GET ACK: NAME: name GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET SYNE STAT: NAME=SYNE:synen; GET SYNE STAT ACK: GET SYNE STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1277 Commands Base Station Controller CML:BSC Application Guidelines: Only sets with raised bits are shown. Example of Command Execution Get SYNE STAT:NAME=SYNE:0; LOCK SYNE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SYNE LOCK SYNE Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "synen" can be found in Appendix A. System Responses: Application Guidelines: 1. If object TRX or CHAN is locked, calls using the concerned objects are dropped. To avoid loss of calls by locking objects TRX or CHAN a request for usage state of this objects should be done previously (e.g. GET state status). In case returned usage state is "active" or "busy" locking should not be done (otherwise calls are dropped). 2. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). LOCK SYNE: NAME=SYNE:synen; LOCK SYNE ACK: LOCK SYNE NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. STANDBY_PLLH_DAC_WORD_EVOLVING It is emitted when the PLLH has become synchronized to an external source little time ago, and the switch of the master PLLH (for LOCK or SWITCH command) would leave the frequency of the new active PLLH with a bad value; it can be answered up to 5 minutes after a SYNC or SYNE has gone PROVIDINGSERVICE. The same can happen if less than 5 minutes have passed since last switch of NTW. 1278 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 3. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock SYNE:NAME=SYNE:0; UNLOCK SYNE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL SYNE UNLOCK SYNE Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "synen" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock SYNE:NAME=SYNE:0; UNLOCK SYNE: NAME=SYNE:synen; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1279 Commands Base Station Controller CML:BSC SYSINIT The SYSINIT (System Initialization) allows different types of system initializations. SYSINIT SYSINIT Command Tree: MANAGED-ELEMENT SOFTWARE-MANAGEMENT SYSINIT SYSINIT SYSINIT Applicability: Phase 2. Visibility level 3. Command Description: This command allows the system to restart the software from a known state. A command acknowledge is requested by the systemby means of a windowCLI message (SYSINIT SYSINIT:SYSINIT:0...EXECUTE COMMAND?); if OK is selected, the command will be executed. The validity range of the object address sysinitn can be found in Appendix A. System Responses: Application Guidelines: 1. To perform SYSINT command with INITLEV equal to TASK_PRIME or TASK_SPARE the operational preconditions are the following: no Change Version operation must be in progress; no patch loading operation must be in progress; no Database saving operation is in progress. 2. When INITLEV option is set at FULL value, there are no operational preconditions, but if the command is performed during a Bring Up or a Change Version Bring Up, the system initialization is automatically upgraded to INITLEV=BU_ACTIVE otherwise the FULL is performed as soon as possible (system must be in normal exercise). SYSINIT SYSINIT: NAME=SYSINIT:sysinitn, INITLEV=; SYSINIT ACK: NAME: name INITLEV: initLevel SYSINIT NACK: NACK CAUSES: CMND_REJECTED_DUE_OTHER_CMND_IN_PROGRESS Patch loading is in progress. Change Version operation is in progress. Save Data Base operation is in progress. 1280 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 3. If the INITLEV option is set at BU_ACTIVE value, there are no operational preconditions; in this case the command forces the MPCC re-loading. Example of Command Execution Sysinit SYSINIT:NAME=SYSINIT:0,INITLEV=BU_ACTIVE; A30808-X3247-L230-3-7619 1281 Commands Base Station Controller CML:BSC TDCU The TDCU (TD-SCDMA Control Unit) is the functional object which provides the TD- SCDMA circuit switched service in SBS. CREATE TDCU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TDCU CREATE TDCU Applicability: Phase 2. Visibility level 2. Command Description: This command creates an instance of the TDCU object class. The procedure of adding a TDCU in SBS is accomplished in two steps: creation of a PPXT functional object; creation of a TDCU functional object. The TDCU number represents the logical number of PPXT card that is active in that moment and has a range between 0 and 4. There is no static association between the physical number of PPXT and the TDCU number: instance n of TDCU could depend hierarchically on instance m of PPXT with n different from m. The validity range of the object address "tdcun" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Create TDCU:NAME=TDCU:0; CREATE TDCU: NAME=TDCU:tdcun; CREATE ACK: Successful CREATE NACK: NACK CAUSES: OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_EXCEEDED_OBJECT_NBR The total number of PPXT equipped must exceed by 2 the total number of already equipped TDCU. 1282 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DELETE TDCU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TDCU DELETE TDCU Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a previously created instance of the TDCU object class. In order to delete a TDCUinstance, the user must first delete one of the PPXT instances already equipped. The validity range of the object address "tdcun" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete TDCU:NAME=TDCU:0; DELETE TDCU: NAME=TDCU:tdcun; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_SUBORDINATE_EQUIPPED No subordinated BTSMTD must be created. A30808-X3247-L230-3-7619 1283 Commands Base Station Controller CML:BSC GET TDCU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TDCU GET TDCU Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameter values of an instance of the TDCU object class. The validity range of the object address "tdcun" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get TDCU:NAME=TDCU:0; GET TDCU: NAME=TDCU:tdcun; GET ACK: NAME: name GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1284 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET TDCU STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TDCU GET TDCU STAT Applicability: Phase 2. Visibility level 0. Command Description: This command ais used to retrieve the following State/Status attributes related to the TDCU object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Unknown Status (UNK). The validity range of the object address "tdcun" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get TDCU STAT:NAME=TDCU:0; GETINFO TDCU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TDCU GETINFO TDCU GET TDCU STAT: NAME=TDCU:tdcun; GET TDCU STAT ACK: GET TDCU STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETINFO TDCU: NAME=TDCU:tdcun; A30808-X3247-L230-3-7619 1285 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The states and statuses of the TDCU: AST, OST, AVS, CTS, PRS. 2. For each BTSTD supported by the TDCU the following information: the BTSMTD, BTSTD and BTSTD absolute number; the AST; the OST; the USG the AVS the PRS The validity range of the object address tdcun can be found in Appendix A. System Responses: GETINFO TDCU ACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** INFORMATION *** GETINFO REPORT TDCU: NAME = TDCU:0 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE CTRST STATUS: NONE STBST STATUS: NONE PROCEDURAL STATUS : NONE BTSMTD:20/BTSTD:0 BTSTD ABSOLUTE NBR: 123 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED USAGE STATE: IDLE AVAILABILITY STATUS: NONE PROCEDURAL STATUS : NONE BTSMTD:2/BTSTD:0 BTSTD ABSOLUTE NBR: 13 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED USAGE STATE: IDLE AVAILABILITY STATUS: NONE PROCEDURAL STATUS : NONE 1286 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller END OF REPORT GETINFO TDCU NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack TDCU: name = TDCU:0 nackCause = <nack cause> Application Guidelines: None. Example of Command Execution Getinfo TDCU:NAME=TDCU:0; GETRELATIONSHIP TDCU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TDCU GETRELATIONSHIP TDCU Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of all the HMOs (Hardware Managed Object) supporting the FMO functionality. The validity range of the object address "tdcun" can be found in Appendix A. NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. GETRELATIONSHIP TDCU: NAME=TDCU:tdcun; A30808-X3247-L230-3-7619 1287 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Getrelationship TDCU:NAME=TDCU:0; GETSUBO TDCU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TDCU GETSUBO TDCU Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "tdcun" can be found in Appendix A. System Responses Application Guidelines: None. GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMOto HMOrelationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. GETSUBO TDCU: NAME=TDCU:tdcu; GETSUBO ACK: The output of the command can be composed by one or more pack with a maximum number of three subordinated mnemonics; at the end there a message is displayed notifying the end of the subordi- nate list. GETSUBO NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1288 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Getsubo TDCU:NAME=TDCU:0; A30808-X3247-L230-3-7619 1289 Commands Base Station Controller CML:BSC LOCK TDCU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TDCU LOCK TDCU Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set the TDCU object at the administrative state "Locked". The validity range of the object address "tdcun" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock TDCU:NAME=TDCU:0; SHUTDOWN TDCU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TDCU SHUTDOWN TDCU Applicability: Phase 2. Visibility level 1. LOCK TDCU: NAME=TDCU:tdcun; LOCK TDCU ACK: LOCK TDCU NACK: NACK CAUSES: INVALID_STATUS ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. SHUTDOWN TDCU: NAME=TDCU:tdcun; 1290 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command allows the graceful transition of the TDCU object fromthe administrative state "Unlocked" to the administrative state "Locked" after the object has terminated its current activity. The BSS is able to force a mobile station to perform an intracell, intercell or inter-BSC HO by means of the O&MSHUTDOWN command. After the SHUTDOWN command is entered, the system tries to perform an intracell, intercell or inter-BSC HO per mobile station; in case of failure, a further attempt is performed every 30 seconds for the next 5 minutes period. If after the predefined period (5.5 minutes) the current activity is not terminated, the administrative state will be set at Locked. If one of the objects is still active or busy after the predefined period, ongoing calls will be dropped. Validity ranges of the object addresses tdcun can be found in Appendix A. System Responses: Application Guidelines: 1. If the operator has started too many shutdown commands, the system will display the SM TOO BUSY message. 2. Possible state transitions and timing: a) UNLOCKED -immediately-> SHUTTING DOWN ---------- immediately ----------> LOCKED b) UNLOCKED -immediately-> SHUTTING DOWN ---------- 5.5 minutes ----------> LOCKED c) UNLOCKED -immediately-> SHUTTING DOWN ---------- after object went to idle state ----------> LOCKED The state changes described above show all the possible transitions when the shut- down command was performed. The rst column of the table gives the situations which are affected by doing a shutdown of an object. Example of Command Execution Shutdown TDCU:NAME=TDCU:0; SHUTDOWN TDCU ACK: SHUTDOWN TDCU NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SITUATIONS TRANSITIONS FORCED/NOT FORCED idle object a) busy object but not released after the SHUTDOWN command b) busy object but released after the SHUTDOWN command c) A30808-X3247-L230-3-7619 1291 Commands Base Station Controller CML:BSC UNLOCK TDCU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TDCU UNLOCK TDCU Applicability: Phase 2. Visibility level 1. Command Description: This command removes the operator block and the unit is reloaded of configuration data. When the TDCUwill be enabled, the systeminformation shall be sent on BCCHchannel in order to informall UEs that the service is available in the cell supported by this TDCU. The validity range of the object address "tdcun" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock TDCU:NAME=TDCU:0; UNLOCK TDCU: NAME=TDCU:tdcun; UNLOCK ACK: Successful UNLOCK NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_STATUS 1292 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TDPC The TDPC object is the telephonic processor of the BSS system. It is a redundant unit in the active/standby mode; it is under the control of MPCC. GET TDPC STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE TDPC GET TDPC STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the BTSM object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Stnadby Status (STNDBY) Unknown Status (UNK). The validity range of the object address "tdpcn" can be found in Appendix A. System Responses: Application Guidelines: Only sets with raised bits are shown. Example of Command Execution Get TDPC STAT:NAME=TDPC:0; GET TDPC STAT: NAME=TDPC:tdpcn; GET TDPC STAT ACK: GET TDPC STAT NACK: NACK CAUSES: A30808-X3247-L230-3-7619 1293 Commands Base Station Controller CML:BSC GETINFO TDPC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE TDPC GETINFO TDPC Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The RSU running object and the RSU version. 2. For each TDPC card: the rmware version the states and statuses: AST, OST, STNDBYST, PRS. 3. The board version: old or new. 4. The active processor operational data (Peak Detection, Mobile Average and Variance for several types of processor data). 5. The operational data of the active processor: real time, current OS time, OS time of last Task init, type and OS time of the last exception, number of task init from last full, number of full init from last bring-up, the exception number from last task, full and bring-up init. 6. For all dynamic memory pool type: the used and total buffer number. 7. Total and largest block available. The validity range of the object address "tdpcn" can be found in Appendix A. System Responses: GETINFO TDPC ACK: BSC_CONTROLLER -> LMT_LOCAL 02:30:41 02/01/1992 *** INFORMATION *** GETINFO REPORT TDPC: NAME = TDPC:0 RSU RUNNING: RSUEXE 0-1 RSU VERSION: 02-06-01-01-00-00_00-01-10 TDPC 0: FIRMWARE VERSION: SFM1101 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED STANDBY STATUS: PROVIDING_SERVICE GETINFO TDPC: NAME=TDPC:tdpcn; 1294 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PROCEDURAL STATUS: NONE TDPC 1: FIRMWARE VERSION: SFM1101 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED STANDBY STATUS: HOT_STANDBY PROCEDURAL STATUS: NONE PROCESSOR TYPE: OLD_BOARD_VERSION ACTIVE PROCESSOR OPERATIONAL DATA: HIGH SPEED LINK PEAK DETECTION (N/TU) LINK A RETRANSMISSION REQUESTS 1111 LINK B RETRANSMISSION REQUESTS 2222 RX FIFO THRESHOLD COUNTER 0 TX FIFO OVERFLOW COUNTER 0 VALID PACKET COUNTER 0 NOT SHARED RAM ACCESS COUNTER 1 SHARED RAM ACCESS COUNTER 3 SHARED RAM WRITING ACCESS COUNTER 3 HIGH SPEED LINK MOBILE AVERAGE VARIANCE LINK A RETRANSMISSION REQUESTS 1111 1111 LINK B RETRANSMISSION REQUESTS 2222 2222 RX FIFO THRESHOLD COUNTER 3232 65100 TX FIFO OVERFLOW COUNTER 3232 23000 VALID PACKET COUNTER 3232 23000 NOT SHARED RAM ACCESS COUNTER 3232 23000 SHARED RAM ACCESS COUNTER 3232 23000 SHARED RAM WRITING ACCESS COUNTER 3232 REAL TIME LOAD: 31% CURRENT OS TIME: 0049:05:54 OS TIME OF LAST TASK INIT: 0000:00:00 OS TIME OF LAST EXCEPTION: 0000:00:00 TYPE OF LAST EXCEPTION: 244 NUMBER OF TASK INIT SINCE LAST FULL INIT: 0001 A30808-X3247-L230-3-7619 1295 Commands Base Station Controller CML:BSC NUMBER OF FULL INIT SINCE LAST BRING-UP: 0001 NUMBER OF EXCEPTION SINCE LAST TASK INIT: 0000 NUMBER OF EXCEPTION SINCE LAST FULL INIT: 0000 NUMBER OF EXCEPTION SINCE LAST BRING-UP INIT: 0000 DYNAMIC MEMORY USAGE: 0: 0017/0050 1: 0057/0100 2: 0019/0064 3: 0012/0030 4: 0017/0031 5: 0000/0001 6: 0000/0001 7: 0001/0068 8: 0002/0200 9: 0000/0070 A: 0000/0014 TOTAL AND LARGEST BLOCK AVAILABLE: 00000001/00022344 END OF REPORT GETINFO TDPC NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack TDPC: name = TDPC:0 nackCause = <nack cause> Application Guidelines: The attribute TYPE OF LAST EXCEPTION is reserved for the developer. Example of Command Execution Getinfo TDPC:NAME=TDPC:0; GETRELATIONSHIP TDPC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE TDPC GETRELATIONSHIP TDPC NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. GETRELATIONSHIP TDPC: NAME=TDPC:tdpcn, ATTID=; 1296 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected HMO (Hardware Managed Object); the relationship information consist of all the FMOs (Functional Managed Object) using the HMO service. This information is included in the RELATED_FUNCTIONAL_OBJECTS attribute (ATTID parameter) and the attribute value depends on the working state of the target HMO. For the TDPC object the MEL is the related FMO. The validity range of the object address "tdpcn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship TDPC:NAME=TDPC:0, ATTID=RELATED_FUNCTIONAL_OBJECTS; GETSUBO TDPC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE TDPC GETSUBO TDPC Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "tdpcn" can be found in Appendix A. GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected HMO the list of related FMOs is displayed (HMO to FMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_ATTRIBUTES The object instance does not provide any relationship attribute. GETSUBO TDPC: NAME=TDPC:tdpcn; A30808-X3247-L230-3-7619 1297 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Getsubo TDPC:NAME=TDPC:0; GETTEST TDPC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE TDPC GETTEST TDPC Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the values of all the attributes belonging to a specified test object; the test object is created by the systemas a result of a request to start a test and it is deleted when the test terminates. The validity range of the object address "tdpcn" can be found in Appendix A. System Responses: GETSUBO TDPC ACK: The output of the command can be composed by one or more packs with a maximum number of ten subordinated mnemonics; at the end there a message is displayed noti- fying the end of the subordinate list. GETSUBO TDPC NACK: NACK CAUSES: GETTEST TDPC: NAME=TDPC:tdpcn; GETTEST TDPC ACK: GETTEST TDPC:NAME=TDPC:0; name = TEST:<n> mOts = TDPC:0 testState = It can assume one of the following values: not_initialized, idle, initializing, suspended, testing, terminating and disabled. testOutcome = It represents the test result: it can be Inconclusive (meaning-less: that is if the phases already executed were successful) or Fail (if at least one of the executed phases failed). testMonitor phaseId = It is a list of the phases to execute and their status that can be: pass, fail, running or waiting. phaseStatus = 1298 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Gettest TDPC:NAME=TDPC:0; LOCK TDPC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE TDPC LOCK TDPC Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The command can be rejected due to high criticity of the system state. The validity range of the object address "tdpcn" can be found in Appendix A. System Responses: phaseId = phaseStatus = .... GETTEST TDPC NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNSUCCESSFUL_WRONG_ME_ID The object address is incorrect. LOCK TDPC: NAME=TDPC:tdpcn; LOCK TDPC ACK: LOCK TDPC NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. CRITICAL_ALARM_REJECTED The command has been rejected due to high criticity of the system state. A30808-X3247-L230-3-7619 1299 Commands Base Station Controller CML:BSC Application Guidelines: 1. If object TRX or CHAN is locked, calls using the concerned objects are dropped. To avoid loss of calls by locking objects TRX or CHAN a request for usage state of this objects should be done previously (e.g. GET state status). In case returned usage state is "active" or "busy" locking should not be done (otherwise calls are dropped). 2. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 3. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock TDPC:NAME=TDPC:0; PERFTEST TDPC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE TDPC PERFTEST TDPC Applicability: Phase 2. Visibility level 2. Command Description: This command is used to perform a test on the selected TDPC object; the test consists of the following phases: Accessibility Test (start phase), Test MEMT Availability (WP1), Test Alarm Circuit - via MEMT (WP2), Test Alarm Circuit - via TDPC (WP3), End Test (end phase). The validity range of the object address "tdpcn" can be found in Appendix A. STANDBY_PLLH_DAC_WORD_EVOLVING It is emitted when the PLLH has become synchronized to an external source little time ago, and the switch of the master PLLH (for LOCK or SWITCH command) would leave the frequency of the new active PLLH with a bad value; it can be answered up to 5 minutes after a SYNC or SYNE has gone PROVIDING SERVICE. The same can happen if less than 5 minutes have passed since last switch of NTW. PERFTEST TDPC: NAME=TDPC:tdpcn; 1300 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: 1. The unit to be diagnosed must be set, through the LOCK command, to the LOCKED state, if the diagnostic is intrusive. PERFTEST TDPC ACK: PERFTEST TDPC:NAME=TDPC:0; testObject=TEST:<n> The test results will be displayed at the end of the test phases. Result TEST: name = TEST:<n> testOutcome = This field represents the test result; one of the following values can be displayed: Pass all the test phases are successfully performed. Inconclusive the test is aborted by the system or the test is terminated by the operator. Fail if at least one of the executed phases fail. mOts = It is the identifier of the hardware object under test. testTermination = It specifies how the test is terminated, it can assume the following values: Normal all the test phases are performed. Abort the test is aborted by system. Cancel the test is terminated by operator. executedPhases phaseId = It represents the list of the executed test phases (in case of successful test result, all the test phases will be listed). additionalWords = .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases phaseId = It represents the list of the skipped phases; they are displayed only for test stopped during it execution. phaseId = .... poprosedRepair Action = A list of most probable fail probable causes is shown (max four messages) PERFTEST TDPC NACK: NACK CAUSES: MOTS_NOT_LOCKED The selected object is not in LOCKED administrative state. OTHER_TESTS_RUNNING Other incompatible tests are already running or no more parallel execution of tests are possible. A30808-X3247-L230-3-7619 1301 Commands Base Station Controller CML:BSC 2. When a test starts on one object, this one goes in "Locked Disabled/Reserved for test" state. When the test result is: "fail" the object goes in Disabled / Failed operational state; "pass" the object goes in Enabled operational state; "inconclusive" the object returns to the operational state previous to the test or in Enabled operational state. Example of Command Execution Perftest TDPC:NAME=TDPC:0; STOPTEST TDPC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE TDPC STOPTEST TDPC Applicability: Phase 2. Visibility level 2. Command Description: This command allows to terminate the test previously requested; the test can be in progress or in the waiting list (queued). In the first case the process that execute the diagnostic will be interrupted by executing the end phase; in the second case the test will be removed from the waiting list. The validity range of the object address "tdpcn" can be found in Appendix A. System Responses: STOPTEST TDPC: NAME=TDPC:tdpcn; STOPTEST TDPC ACK: STOPTEST TDPC:NAME=TDPC:0; testObject=TEST:<n> Result TEST: name = TEST:<n> testOutcome = inconclusive mOts = TDPC:0 testTermination = Cancel executedPhases phaseId = It represents the list of the executed test phases; the list is not shown for test in the waiting list (queued). .... failedPhases phaseId = It represents the list of the failed test phase; additional information is provided for each phase. phaseId = .... skippedPhases 1302 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Stoptest TDPC:NAME=TDPC:0; SWITCH TDPC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE TDPC SWITCH TDPC Applicability: Phase 2. Visibility level 1. Command Description: This command allows the standby status exchange of the duplicated objects from "Providing Service" to "Hot Standby" and viceversa. The validity range of the object address "tdpcn" can be found in Appendix A. System Responses: phaseId = It represents the list of the skipped phases;the list is not shown for test in the waiting list (queued). phaseId = .... STOPTEST TDPC NACK: NACK CAUSES: NO_SUCH_TEST The test is not active. UNABLE_TO_STOP_TEST The test can not be stopped. SWITCH TDPC: NAME=TDPC:tdpcn; SWITCH TDPC ACK: SWITCH TDPC NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE OTHER_COPY_INVALID_STATE A30808-X3247-L230-3-7619 1303 Commands Base Station Controller CML:BSC Application Guidelines: 1. The selected object must be equipped and in "enabled-providing service" state and its duplicated copy must be in "enable-cold/hot standby" state. 2. It is not possible to enter more than one SWITCH TDPC command per minute. 3. The network switch command cannot be performed within 5 minutes from the previous one if a SYNC or SYNE object is congured due to hardware constraints. Example of Command Execution Switch TDPC:NAME=TDPC:0; UNLOCK TDPC Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT BSCE TDPC UNLOCK TDPC Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "tdpcn" can be found in Appendix A. System Responses: Application Guidelines: 1. Unlocking of BTSM causes a full BTS alignment. 2. It is possible to unlock the TDPC card with the status in LOCKED and UNDER TEST. UNSUCCESSFUL_COMMAND_REJECTED STANDBY_PLLH_DAC_WORD_EVOLVING It is emitted when the PLLH has become synchronized to an external source little time ago, and the switch of the master PLLH (for LOCK or SWITCH command) would leave the frequency of the new active PLLH with a bad value; it can be answered up to 5 minutes after a SYNC or SYNE has gone PROVIDING SERVICE. The same can happen if less than 5 minutes have passed since last switch of NTW. UNLOCK TDPC: NAME=TDPC:tdpcn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. 1304 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Unlock TDPC:NAME=TDPC:0; A30808-X3247-L230-3-7619 1305 Commands Base Station Controller CML:BSC TGTBTS The TGTBTS (Target BTS) managed object instance contains a copy of the attributes involved in the management of the adjacency of an external BTS. Once a TGTBTS is configured it is treated by the system, for the management of the adjacencies, as the other internal target BTSs. This means that, in the case in which the external target BTS is adjacent to more than one internal serving BTS, it is no more necessary to replicate all the attribute values in every ADJC managed object instance, but it is enough that the different ADJCs refer to the same TGTBTS. CREATE TGTBTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTS CREATE TGTBTS Applicability: Phase 2. Visibility level 2. Command Description: This command allows to create a target BTS object used to manage the adjacency. This object will be selected by means of the TGTCELL parameter of the ADJC object. The validity range of the object address tgtbtsn can be found in Appendix A. System Responses: CREATE TGTBTS: NAME=TGTBTS:tgtbtsn, CELLGLID=, BSIC=, BCCHFREQ=, SYSID= [,MSTXPMAXGSM=] [,MSTXPMAXDCS=] [,MSTXPMAXPCS=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. For more details, see Application Guidelines n. 1 and n. 3. UNSUCCESSFUL_CELL_GLOB_ID All the fields (MCC, MNC, LAC, CI) of cellGlobalIdentity must be set. The CELLGLID cannot be equal to the CELLGLID assigned to other adjacent cells (ADJC) and to the serving cell (BTS). The CELLGLIDcannot be equal to the CELLGLIDassigned to another BTS, TGTBTS, BTSTD, or TGTBTSTD. BCCF_AND_BSIC_BELONG_TO_ANOTHER_CELL 1306 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. Three attributes in the TGTBTS object are formatted in digits. The attributes are: the MobileCountryCode (MCC) and the MobileNetworkCode (MNC) contained in the CellGlobalId (CELLGLID) the bSIdentityCode (BSIC) 2. Location Area Identity (LAI) = MCC + MNC + LAC Cell Global Identity = LAI + CI 3. Each of the attributes MSTXPMAXGSM, MSTXPMAXDCS and MSTXPMAXPCS can be set only if the SYSID refers to the corresponding band; otherwise they must be skipped or assume the value <NULL>. 4. For the different SYSID setting, the following msTxPwrMax parameters must be used: ARFCN (bcchFrequency) and BSIC (bsIdentityCode) set values must not belong to another adjacent cell of the BTS. UNSUCCESSFUL_VAR_OUT_OF_RANGE One or more variables have been incorrectly set. For more details see Application Guideline n. 4. WRONG_SYSID The value set for the SYSID parameter is incorrect. For more details, see Application Guideline n. 5. UNSUCCESSFUL_FREQ_OUT_OF_RANGE The selected frequency is out of range. For more details, see Application Guideline n. 6. UNSUCCESSFUL_INVALID_BCCH_FREQUENCY In GSM850DCS cells: the band of BCCH frequency cannot be changed. UNSUCCESSFUL_EXCEED_OBJECT_NBR With MPCCV7 board or old BSC rack type, no more than 650 TGTBTS instances can be created in the whole BSC. CELLGLID = MCC-MNC-LAC-CI Note that: MCC = D1D2D3 MNC = D1D2D3 Dx means digit (only numerical characters shall be used; for numbers from 0 to 9 it must be entered one digit). In fact 9 is different from 09. For MCC and MNC all digits are mandatory. BSIC = D1D2 Dx means digit (only numerical characters 0..7 shall be used) Note that D1 is the NetworkColourCode (NCC) and D2 is the BTSColourCode (BCC) These attributes are stored in the system in their decimal representation (which is the input format) but it is necessary to check the range of each digit: MCC, MNC 0 =< Dx =< 9 BSIC 0 =< Dx =< 7 A30808-X3247-L230-3-7619 1307 Commands Base Station Controller CML:BSC If SYSID equals BB900, EXT900, F2ONLY900, GSMDCS, GSMR, GSM850, GSM850PCS or GSM850DCS the MSTXPMAXGSM must be set. If SYSID equals DCS1800, GSMDCS or GSM850DCS the MSTXPMAXDCS must be set. If SYSID equals PCS1900 or GSM850PCS the MSTXPMAXPCS must be set. If SYSID equals GSMDCS or GSM850DCS the MSTXPMAXGSMmust be set at 2..15 (for the GSMpart of the cell), and the MSTXPMAXDCS must be set at 0..15 (for the DCS part of the cell). If SYSID equals GSM850PCS the MSTXPMAXGSMmust be set at 2..15 (for the GSMpart of the cell), and the MSTXPMAXPCS must be set at 0..15, 30 or 31 (for the PCS part of the cell). 5. The SYSID parameter can assume 10 values: BB900 (GSM Standard Band); F2ONLY900 (GSM Extended Band); EXT900 (GSM Mixed Band) GSMR (Railway Band) PCS1900 DCS1800 GSMDCS GSM850 GSM850PCS GSM850DCS If the NETWTYPE parameter (previously set by the SET BSC command) is GSMDCS then only the BB900, F2ONLY900, EXT900, DCS1800 and GSMDCS values are permitted to the SYSID. If the NETWTYPE parameter is GSMRthen only the GSMRvalue is permitted to the SYSID. If the NETWTYPE parameter is GSMPCS then only the BB900, F2ONLY900, EXT900 and PCS1900 values are permitted to the SYSID. If the NETWTYPEparameter is GSM850PCSthen only GSM850, GSM850PCSand PCS1900 values are permitted to the SYSID. If there are not BB900 BTSs in the BSC the SYSID attribute can be F2ONLY900. If there are not F2ONLY900 BTSs in the BSC the SYSID attribute can be BB900. If the NETWTYPE parameter (previously set by the SET BSC command) is GSM850DCSthen only GSM850, GSM850DCSand DCS1800 values are permitted to the SYSID. 6. The BCCHFREQ attribute must follow these rules: if SYSID = BB900 then 1 =< BCCHFREQ =< 124 if SYSID = F2ONLY900 then 0 =< BCCHFREQ =< 124 975 =< BCCHFREQ =< 1023 if SYSID = EXT900 then 0 =< BCCHFREQ =< 124 975 =< BCCHFREQ =< 1023 if SYSID = DCS1800 then 512 =< BCCHFREQ =< 885 if SYSID = GSMR then 955 =< BCCHFREQ =< 974 if SYSID = PCS1900 then 512 =< BCCHFREQ =< 810 if SYSID = GSMDCS then 0 = < BCCHFREQ =< 124 975 = < BCCHFREQ =< 1023 (GSM extended band) 1308 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 7. Regarding the number of allowed TGTBTS instances the following rules are valid: in case of MPCC V7 (old hardware) the sum: (number of TGTBTS) + (number of TGTTDD) + (number of TGTFDD) must be <= 650, and at most 650 instances (0..649) can be created for all the three classes; in case of MPCC V8 (new hardware) the sum: (number of TGTBTS) + (number of TGTTDD) + (number of TGTFDD) must be <= 1500, and at most 1500 instances (0..1499) can be created for all the three classes. Example of Command Execution Create TGTBTS:NAME=TGTBTS:0,CELLGLID="123"-"45"-1-1,BSIC=1-2, BCCHFREQ=35,SYSID=BB900,MSTXPMAXGSM=2; DELETE TGTBTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTS DELETE TGTBTS Applicability: Phase 2. Visibility level 2. Command Description: This command allow to delete a previously created TGTBTS object. The validity range of the object address tgtbtsn can be found in Appendix A. System Responses: Application Guidelines: None. 512 =< BCCHFREQ =< 885 (DCS 1800) If SYSID = GSM850 then 128 =< BCCHFREQ =< 251 If SYSID = GSM850PCS then 128 =< BCCHFREQ =< 251 512 =< BCCHFREQ =< 810 If SYSID = GSM850DCS then 128 =< frequency =< 251 (GSM_850) 512 =< frequency =< 885 (DCS 1800) DELETE TGTBTS NAME=TGTBTS:tgtbtsn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1309 Commands Base Station Controller CML:BSC Example of Command Execution Delete TGTBTS:NAME=TGTBTS:0; 1310 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET TGTBTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTS GET TGTBTS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of the parameters, selected by the operator, related to the target BTS object. The validity range of the object address tgtbtsn can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get TGTBTS:NAME=TGTBTS:0,REQATTL=CELLGLID&BSIC&BCCHFREQ& SYSID&MSTXPMAXGSM&MSTXPMAXDCS&MSTXPMAXPCS; GET TGTBTS NAME=TGTBTS:tgtbtsn [,REQATTL=CELLGLID, BSIC, BCCHFREQ, SYSID, MSTXPMAXGSM, MSTXPMAXDCS, MSTXPMAXPCS]; GET ACK: NAME: name CELLGLID: cellGlobalIdentity BSIC: bsIdentityCode BCCHFREQ: bcchFrequency SYSID: systemIndicator MSTXPMAXGSM: msTxPwrMaxGsm MSTXPMAXDCS: msTxPwrMaxDcs MSTXPMAXPCS: msTxPwrMaxPcs GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1311 Commands Base Station Controller CML:BSC GET TGTBTS BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTS GET TGTBTS BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address tgtbtsn can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get TGTBTS BASICS:NAME=TGTBTS:0; SET TGTBTS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTS SET TGTBTS GET TGTBTS BASICS: NAME=TGTBTS:tgtbtsn; GET TGTBTS BASICS ACK: NAME: name CELLGLID: cellGlobalIdentity BSIC: bsIdentityCode BCCHFREQ: bcchFrequency SYSID: systemIndicator MSTXPMAXGSM: msTxPwrMaxGsm MSTXPMAXDCS: msTxPwrMaxDcs MSTXPMAXPCS: msTxPwrMaxPcs GET TGTBTS BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SET TGTBTS: NAME=TGTBTS:tgtbtsn [,CELLGLID=] [,BSIC=] [,BCCHFREQ=] [,SYSID=] [,MSTXPMAXGSM=] [,MSTXPMAXDCS=] [,MSTXPMAXPCS=]; 1312 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 2. Command Description: This command allows to modify the specific parameters for a target BTS object. The validity range of the object address tgtbtsn can be found in Appendix A. System Responses: SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. For more details, see Application Guidelines n. 1 and n. 3. UNSUCCESSFUL_CELL_GLOB_ID All the fields (MCC, MNC, LAC, CI) of cellGlobalIdentity must be set. The CELLGLID cannot be equal to the CELLGLID assigned to other adjacent cells (ADJC) and to the serving cell (BTS). The CELLGLIDcannot be equal to the CELLGLIDassigned to another BTS, TGTBTS, BTSTD, or TGTBTSTD. BCCF_AND_BSIC_BELONG_TO_ANOTHER_CELL ARFCN (bcchFrequency) and BSIC (bsIdentityCode) set values must not belong to another adjacent cell of the BTS. UNSUCCESSFUL_BCCF_OUT_OF_RANGE The selected BCCF is not allowed for the selected SYSID value. UNSUCCESSFUL_FREQUENCY_UNDER_MEASURE The BCCH frequency cannot be changed if the TGTBTS is the target cell of an ADJC which has its BCCH frequency traced by the relative SCA (see NMDLATT <nn> parameter of the SCA object). UNSUCCESSFUL_VAR_OUT_RANGE One or more variables have been incorrectly set. For more details, see Application Guideline n. 4. WRONG_SYSID The value set for the SYSID parameter is incorrect. For more details, see Application Guideline n. 5. UNSUCCESSFUL_FREQ_OUT_OF_RANGE The selected frequency is out of range. For more details, see Application Guideline n. 6. UNSUCCESSFUL_INVALID_BCCH_FREQUENCY In GSMDCS, GSM850PCS, GSM850DCS cells the BCCH frequency band cannot be changed. MAX_ADJC_COMPL_BAND_EXCEEDED The number of the adjacent cells having their BCCHFREQ in the complementary band exceeds the allowed maximum number. For more details, see Application Guideline n. 7. A30808-X3247-L230-3-7619 1313 Commands Base Station Controller CML:BSC Application Guidelines: 1. Three attributes in the TGTBTS object are formatted in digits. The attributes are: the MobileCountryCode (MCC) and the MobileNetworkCode (MNC) contained in the CellGlobalId (CELLGLID) the bSIdentityCode (BSIC) 2. Location Area Identity (LAI) = MCC + MNC + LAC Cell Global Identity = LAI + CI 3. Each of the attributes MSTXPMAXGSM, MSTXPMAXDCS and MSTXPMAXPCS can be set only if the SYSID refers to the corresponding band; otherwise they must be skipped or assume the value <NULL>. 4. For the different SYSID setting, the following msTxPwrMax parameters must be used: If SYSID equals BB900, EXT900, F2ONLY900, GSMDCS, GSMR, GSM850, GSM850PCS or GSM850DCS the MSTXPMAXGSM must be set. If SYSID equals DCS1800, GSMDCS or GSM850DCS the MSTXPMAXDCS must be set. If SYSID equals PCS1900 or GSM850PCS the MSTXPMAXPCS must be set. If SYSID equals GSMDCS or GSM850DCS the MSTXPMAXGSMmust be set at 2..15 (for the GSMpart of the cell), and the MSTXPMAXDCS must be set at 0..15 (for the DCS part of the cell). If SYSID equals GSM850PCS the MSTXPMAXGSMmust be set at 2..15 (for the GSMpart of the cell), and the MSTXPMAXPCS must be set at 0..15, 30 or 31 (for the PCS part of the cell). 5. The SYSID parameter can assume 10 values: BB900 (GSM Standard Band); F2ONLY900 (GSM Extended Band); EXT900 (GSM Mixed Band) GSMR (Railway Band) PCS1900 DCS1800 GSMDCS GSM850 CELLGLID = MCC-MNC-LAC-CI Note that: MCC = D1D2D3 MNC = D1D2D3 Dx means digit (only numerical characters shall be used; for numbers from 0 to 9 it must be entered one digit). In fact 9 is different from 09. For MCC and MNC all digits are mandatory. BSIC = D1D2 Dx means digit (only numerical characters 0..7 shall be used) Note that D1 is the NetworkColourCode (NCC) and D2 is the BTSColourCode (BCC) These attributes are stored in the DBC in their decimal representation (which is the input format) but it is necessary to check the range of each digit: MCC,MNC 0 =< Dx =< 9 BSIC 0 =< Dx =< 7 1314 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GSM850PCS GSM850DCS If the NETWTYPE parameter (previously set by the SET BSC command) is GSMDCS then only the BB900, F2ONLY900, EXT900, DCS1800 and GSMDCS values are permitted to the SYSID. If the NETWTYPE parameter is GSMRthen only the GSMRvalue is permitted to the SYSID. If the NETWTYPE parameter is GSMPCS then only the BB900, F2ONLY900, EXT900 and PCS1900 values are permitted to the SYSID. If the NETWTYPEparameter is GSM850PCSthen only GSM850, GSM850PCSand PCS1900 values are permitted to the SYSID. If there are no BB900 BTSs in the BSC the SYSID attribute can be F2ONLY900. If there are no F2ONLY900 BTSs in the BSC the SYSID attribute can be BB900. If the NETWTYPE parameter is GSM850DCS then only GSM850, GSM850DCS and DCS1800 values are permitted to the SYSID. 6. The BCCHFREQ attribute must follow these rules: 7. The maximumnumber of adjacent cells having their BCCHFREQin the complemen- tary band, with respect to the SYSID of the serving cell, depends on the delta between the lowest and the highest frequency of the ADJCs belonging to this subset, as shown in the following table. if SYSID = BB900 then 1 =< BCCHFREQ =< 124 if SYSID = F2ONLY900 then 0 =< BCCHFREQ =< 124 975 =< BCCHFREQ =< 1023 if SYSID = EXT900 then 0 =< BCCHFREQ =< 124 975 =< BCCHFREQ =< 1023 if SYSID = DCS1800 then 512 =< BCCHFREQ =< 885 if SYSID = GSMR then 955 =< BCCHFREQ =< 974 if SYSID = PCS1900 then 512 =< BCCHFREQ =< 810 if SYSID = GSMDCS then 0 = < BCCHFREQ =< 124 975 = < BCCHFREQ =< 1023 (GSM extended band) 512 =< BCCHFREQ =< 885 (DCS 1800) If SYSID = GSM850 then 128 =< BCCHFREQ =< 251 If SYSID = GSM850PCS then 128 =< BCCHFREQ =< 251 512 =< BCCHFREQ =< 810 if SYSID = GSM850DCS then 128 =< BCCHFREQ =< 251 512 =< BCCHFREQ =< 885 (DCS 1800) Max Number of ADJC in complementary Band Delta 16 Any 17 Any, if frequency 0 is present 18 512 22 256 A30808-X3247-L230-3-7619 1315 Commands Base Station Controller CML:BSC Example of Command Execution Set TGTBTS:NAME=TGTBTS:0,CELLGLID="123"-"45"-1-1,BSIC=1-2, BCCHFREQ=35,SYSID=DCS1800,MSTXPMAXDCS=0; 29 128 All 111 or frequency in BB900 band Max Number of ADJC in complementary Band Delta 1316 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TGTBTSTD The TGTBTSTD(Target BTSfor TD-SCDMA) managed object instance contains a copy of the attributes involved in the management of the adjacency of an external BTSTD. Once a TGTBTSTD is configured it is treated by the system, for the management of the adjacencies, as the other internal target BTSTDs. This means that, in the case in which the external target BTSTDis adjacent to more than one internal serving BTSTD, it is no necessary to replicate all the attribute values in every ADJCTD managed object instance, but it is enough that the different ADJCTDs refer to the same TGTBTSTD. CREATE TGTBTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTSTD CREATE TGTBTSTD Applicability: Phase 2. Visibility level 2. Command Description: This command allows to create a target BTSTD object used to manage the adjacency. This object will be selected by means of the TGTCELL parameter of the ADJCTDobject. The validity range of the object address tgtbtstdn can be found in Appendix A. System Responses: CREATE TGTBTSTD: NAME=TGTBTSTD:tgtbtstdn, CELLGLID=, BSIDC=, BCCHFREQTD= [,UETSCPMAC=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. For more details, see Application Guidelines n. 1. UNSUCCESSFUL_CELL_GLOB_ID All the fields (MCC, MNC, LAC, CI) of cellGlobalIdentity must be set. The CELLGLIDcannot be equal to the CELLGLIDassigned to another BTS, TGTBTS, BTSTD, or TGTBTSTD. BCCFTD_AND_BSIDC_BELONG_TO_ANOTHER_CELL The pair BCCHFREQTD - BSIDC is equal to the pair BCCHFREQTD - BSIDC of either an existing cell (BTSTD) or an existing TGTBTSTD. A30808-X3247-L230-3-7619 1317 Commands Base Station Controller CML:BSC Application Guidelines: 1. Three attributes in the TGTBTSTD object are formatted in digits. The attributes are: the MobileCountryCode (MCC) and the MobileNetworkCode (MNC) contained in the CellGlobalId (CELLGLID) the bSIdentityCodeTD (BSIDC) 2. Location Area Identity (LAI) = MCC + MNC + LAC Cell Global Identity = LAI + CI Example of Command Execution Create TGTBTSTD:NAME=TGTBTSTD:0,CELLGLID="123"-"45"-1-1,BSIDC=1-2, BCCHFREQTD=35,UETSCPMAC=[-17]; DELETE TGTBTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTSTD DELETE TGTBTSTD Applicability: Phase 2. Visibility level 2. UNSUCCESSFUL_INVALID_ATTRIBUTES Feature supported only by new MPCC/TDPC. UNSUCCESSFUL_COMMAND_REJECTED Invalid Rack type:feature supported only by NTWSNAP_STLP. CELLGLID = MCC-MNC-LAC-CI Note that: MCC = D1D2D3 MNC = D1D2D3 Dx means digit (only numerical characters shall be used; for numbers from 0 to 9 it must be entered one digit). In fact 9 is different from 09. For MCC and MNC all digits are mandatory. BSIDC = D1D2 Dx means digit (only numerical characters 0..7 shall be used) Note that D1 is the NetworkColourCode (NCC) and D2 is the BTSColourCode (BCC) These attributes are stored in the system in their decimal representation (which is the input format) but it is necessary to check the range of each digit: MCC, MNC 0 =< Dx =< 9 BSIDC 0 =< Dx =< 7 DELETE TGTBTSTD NAME=TGTBTSTD:tgtbtstdn; 1318 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command allows to delete a previously created TGTBTSTD object. The validity range of the object address tgtbtstdn can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete TGTBTSTD:NAME=TGTBTSTD:0; GET TGTBTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTTD GET TGTBTSTD Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of the parameters, selected by the operator, related to the target BTSTD object. The validity range of the object address tgtbtstdn can be found in Appendix A. System Responses: DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_SUBORDINATE_EQUIPPED The TGTBTSTD cannot be deleted if it is referenced as target cell by any ADJCTD. GET TGTBTSTD NAME=TGTBTSTD:tgtbtstdn [,REQATTL=CELLGLID, BSIDC, BCCHFREQTD, UETSCPMAC]; GET ACK: NAME: name CELLGLID: cellGlobalIdentity BSIDC: bsIdentityCodeTD BCCHFREQTD: bcchFrequencyTD UETSCPMAC: ueTSCPMaxCell A30808-X3247-L230-3-7619 1319 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get TGTBTSTD:NAME=TGTBTSTD:0,REQATTL=CELLGLID&BSIDC& BCCHFREQTD&UETSCPMAC; GET TGTBTSTD BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTSTD GET TGTBTSTD BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address tgtbtstdn can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get TGTBTSTD BASICS:NAME=TGTBTSTD:0; GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET TGTBTSTD BASICS: NAME=TGTBTSTD:tgtbtstdn; GET TGTBTSTD BASICS ACK: NAME: name CELLGLID: cellGlobalIdentity BSIDC: bsIdentityCodeTD BCCHFREQTD: bcchFrequencyTD UETSCPMAC: ueTSCPMaxCell GET TGTBTSTD BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1320 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SET TGTBTSTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTSTD SET TGTBTSTD Applicability: Phase 2. Visibility level 2. Command Description: This command allows to modify the specific parameters for a target BTSTD object. The validity range of the object address tgtbtstdn can be found in Appendix A. System Responses: Application Guidelines: 1. Three attributes in the TGTBTSTD object are formatted in digits. The attributes are: the MobileCountryCode (MCC) and the MobileNetworkCode (MNC) contained in the CellGlobalId (CELLGLID) SET TGTBTSTD: NAME=TGTBTSTD:tgtbtstdn [,CELLGLID=] [, BSIDC=] [,BCCHFREQTD=] [,UETSCPMAC=]; SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES One or more attributes have been incorrectly set. For more details, see Application Guidelines n. 1. UNSUCCESSFUL_CELL_GLOB_ID All the fields (MCC, MNC, LAC, CI) of cellGlobalIdentity must be set The CELLGLIDcannot be equal to the CELLGLIDassigned to another BTS, TGTBTS, BTSTD, or TGTBTSTD. BCCFTD_AND_BSIDC_BELONG_TO_ANOTHER_CELL The pair BCCHFREQTD-BSIDC is equal to the pair BCCHFREQTD-BSIDC of either an existing cell (BTSTD) or an existing TGTBTSTD. CELLGLID = MCC-MNC-LAC-CI Note that: MCC = D1D2D3 MNC = D1D2D3 Dx means digit (only numerical characters shall be used; for numbers from 0 to 9 it must be entered one digit). In fact 9 is different from 09. For MCC and MNC all digits are mandatory. A30808-X3247-L230-3-7619 1321 Commands Base Station Controller CML:BSC the bSIdentityCodeTD (BSIDC) 2. Location Area Identity (LAI) = MCC + MNC + LAC Cell Global Identity = LAI + CI Example of Command Execution Set TGTBTSTD:NAME=TGTBTSTD:0,CELLGLID="123"-"45"-1-1,BSIDC=1-2, BCCHFREQTD=35,UETSCPMAC=[-17]; BSIDC = D1D2 Dx means digit (only numerical characters 0..7 shall be used) Note that D1 is the NetworkColourCode (NCC) and D2 is the BTSColourCode (BCC) These attributes are stored in the DBC in their decimal representation (which is the input format) but it is necessary to check the range of each digit: MCC,MNC 0 =< Dx =< 9 BSIDC 0 =< Dx =< 7 1322 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TGTFDD CREATE TGTFDD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTFDD CREATE TGTFDD Applicability: Phase 2. Visibility level 2. Command Description: This command allows to create a target FDD object. The validity range of the object address "tgtfddn" can be found in Appendix A. System Responses: Application Guidelines: Regarding the number of allowed TGTFDD instances the following rules are valid: in case of MPCC V7 (old hardware) the sum: (number of TGTBTS) + (number of TGTTDD) + (number of TGTFDD) must be <= 650, and at most 650 instances (0..649) can be created for all the three classes; in case of MPCC V8 (new hardware) the sum: (number of TGTBTS) + (number of TGTTDD) + (number of TGTFDD) must be <= 1500, and at most 1500 instances (0..1499) can be created for all the three classes. CREATE TGTFDD: NAME=TGTFDD:tgtfddn ,CELLGLID= ,FDDARFCN= ,RNCID= ,FDDSCRMC= ,FDDDIV= [,MSTXPMAXUMTS=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_CELL_GLOB_ID All the fields of CELLGLID attribute must be set. The CELLGLID fields are not in correct format. The pair CELLGLID and RNCID has been already used. UNSUCCESSFUL_INVALID_ATTRIBUTES The pair FDDARFCN and FDDSCRMC has been already used. FDDARFCN value is not included between 9662 and 9938 or between 412 and 687 or between 10562 and 10838. A30808-X3247-L230-3-7619 1323 Commands Base Station Controller CML:BSC Example of Command Execution Create TGTFDD:NAME=TGTFDD:0,CELLGLID="123"-"456"-1-1, FDDARFCN=9662,RNCID=0,FDDSCRMC=2,FDDDIV=NO_DIVERSITY, MSTXPMAXUMTS=49; DELETE TGTFDD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTFDD DELETE TGTFDD Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a previously created instance of the TGTFDD object class. The validity range of the object address "tgtfddn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete TGTFDD:NAME=TGTFDD:0; DELETE TGTFDD NAME=TGTFDD:tgtfddn; DELETE ACK: DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_SUBORDINATE_EQUIPPED The TGTFDD object instance cannot be deleted if is referenced as the target cell by any ADJC3G object instance. 1324 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET TGTFDD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTFDD GET TGTFDD Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameter values of an instance of the TGTFDD object class. The validity range of the object address "tgtfddn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get TGTFDD:NAME=TGTFDD:0,REQATTL=CELLGLID&FDDARFCN& RNCID&FDDSCRMC&FDDDIV&MSTXPMAXUMTS; GET TGTFDD NAME=TGTFDD:tgtfddn [,REQATTL= CELLGLID, FDDARFCN, RNCID, FDDSCRMC, FDDDIV, MSTXPMAXUMTS]; GET ACK: NAME: name CELLGLID: cellGlobalIdentity FDDARFCN: fddArfcn RNCID: rncId FDDSCRMC: fddScramblingCode FDDDIV: fddDiversity MSTXPMAXUMTS:msTxPwrMaxUmts GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1325 Commands Base Station Controller CML:BSC GET TGTFDD BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTFDD GET TGTFDD BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "tgtfddn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get TGTFDD BASICS:NAME=TGTFDD:0; SET TGTFDD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTFDD SET TGTFDD GET TGTFDD BASICS NAME=TGTFDD:tgtfddn; GET TGTFDD BASICS ACK: NAME: name CELLGLID: cellGlobalIdentity FDDARFCN: fddArfcn RNCID: rncId FDDSCRMC: fddScramblingCode FDDDIV: fddDiversity MSTXPMAXUMTS:msTxPwrMaxUmts GET TGTFDD BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SET TGTFDD: NAME=TGTFDD:tgtfddn [,CELLGLID=] [,FDDARFCN=] [,RNCID=] [,FDDSCRMC=] [,FDDDIV=] [,MSTXPMAXUMTS=]; 1326 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 2. Command Description: This command modifies the specific parameters of the TGTFDD object class. The validity range of the object address "tgtfddn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Set TGTFDD:NAME=TGTFDD:0,CELLGLID="123"-"456"-1-1, FDDARFCN=9662,RNCID=0,FDDSCRMC=2,FDDDIV=NO_DIVERSITY, MSTXPMAXUMTS=49; SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_CELL_GLOB_ID The CELLGLID fields are not in correct format. The pair CELLGLID and RNCID has been already used. UNSUCCESSFUL_INVALID_ATTRIBUTES The pair FDDARFCN and FDDSCRMC has been already used. FDDARFCN value is not included between 9662 and 9938 or between 412 and 687 or between 10562 and 10838. A30808-X3247-L230-3-7619 1327 Commands Base Station Controller CML:BSC TGTPTPPKF The TGTPPKF (Target Point-To-Point Packet Frame) is hierarchically dependent by the TGTBTS in the containment tree. A TGTPTPPKF managed object instance contains a copy of the attributes, of an external PTPPKF, involved in the management of the adjacency. Once a TGTPTPPKF is configured, it is treated by the system, for the management of the adjacencies, as the other internal target PTPPKFs. Therefore, in case of internal adjacency, the TGTCELL will identify the PTPPKF target through the reference to the superordinate BTS. In case of external adjacency, the TGTCELL will identify the TGTPTPPKF target through the reference to the superordinate TGTBTS. CREATE TGTPTPPKF Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTS TGTPTPPKF CREATE TGTPTPPKF Applicability: Phase 2. Visibility level 2. Command Description: This command allows to create a target PTPPKF object which identify the target cell that belongs to a BSC different from that of the serving cell. Validity ranges of the object addresses tgtbtsn and "tgtptppkfn" can be found in Appendix A. System Responses: Application Guidelines: If the GPRS service is present in the cells, the order of creation of the objects involved in the adjacency management is the following: The target TGTBTS has no superordinated. CREATE TGTPTPPKF: NAME=TGTBTS:tgtbtsn/TGTPTPPKF:tgtptppkfn ,RACODE= ,RACOL= [,GRXLAMI=] [,GMSTXPMAC=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The TGTBTS object instance must be already created. 1328 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller The target TGTPTPPKF has to be created only after the creation of the superordi- nated TGTBTS. The serving PTPPKF has to be created only after the creation of the superordinated serving BTS. An ADJC, related to an external BTS target, has to be created only after the creation of the superordinated serving BTS and the related serving PTPPKF, target TGTBTS and target TGTPTPPKF. Example of Command Execution Create TGTPTPPKF:NAME=TGTBTS:0/TGTPTPPKF:0,RACODE=22, RACOL=0,GRXLAMI=0,GMSTXPMAC=2; DELETE TGTPTPPKF Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTS TGTPTPPKF DELETE TGTPTPPKF Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a previously created instance of the TGTPTPPKF object class. Validity ranges of the object addresses tgtbtsn and "tgtptppkfn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete TGTPTPPKF:NAME=TGTBTS:0/TGTPTPPKF:0; DELETE TGTPTPPKF NAME=TGTBTS:tgtbtsn/TGTPTPPKF:tgtptppkfn; DELETE ACK: DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1329 Commands Base Station Controller CML:BSC GET TGTPTPPKF Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTS TGTPTPPKF GET TGTPTPPKF Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameter values of an instance of the TGTPTPPKF object class. Validity ranges of the object addresses tgtbtsn and "tgtptppkfn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get TGTPTPPKF:NAME=TGTBTS:0/TGTPTPPKF:0, REQATTL=RACODE&RACOL&GRXLAMI&GMSTXPMAC; GET TGTPTPPKF NAME=TGTBTS:tgtbtsn/TGTPTPPKF:tgtptppkfn [,REQATTL=RACODE, RACOL, GRXLAMI, GMSTXPMAC]; GET ACK: NAME: name RACODE: routingAreaCode RACOL: routingAreaColour GRXLAMI: gprsLevAccessMin GMSTXPMAC: gprsMsTxPwrMaxCch GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1330 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET TGTPTPPKF BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTS TGTPTPPKF GET TGTPTPPKF BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses tgtbtsn and "tgtptppkfn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get TGTPTPPKF BASICS:NAME=TGTBTS:0/TGTPTPPKF:0; SET TGTPTPPKF Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTS TGTPTPPKF SET TGTPTPPKF GET TGTPTPPKF BASICS NAME=TGTBTS:tgtbtsn/TGTPTPPKF:tgtptppkfn; GET TGTPTPPKF BASICS ACK: NAME: name RACODE: routingAreaCode RACOL: routingAreaColour GRXLAMI: gprsLevAccessMin GMSTXPMAC: gprsMsTxPwrMaxCch GET TGTPTPPKF BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SET PTPPKF: NAME=TGTBTS:tgtbtsn/TGTPTPPKF:tgtptppkfn [,RACODE=] [,RACOL=] [,GRXLAMI=] [,GMSTXPMAC=]; A30808-X3247-L230-3-7619 1331 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 2. Command Description: This command modifies the specific parameters of the TGTPTPPKF object class. Validity ranges of the object addresses tgtbtsn and "tgtptppkfn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Set TGTPTPPKF:NAME=TGTBTS:0/TGTPTPPKF:0,RACODE=22,RACOL=0, GRXLAMI=0,GMSTXPMAC=2; SET ACK: SET NACK: NACK CAUSES: UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The relevant TGTBTS object instance must be already created. 1332 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TGTTDD CREATE TGTTDD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTTDD CREATE TGTTDD Applicability: Phase 2. Visibility level 2. Command Description: This command allows to create a target TDD object. The validity range of the object address "tgttddn" can be found in Appendix A. System Responses: Application Guidelines: Regarding the number of allowed TGTTDD instances the following rules are valid: in case of MPCC V7 (old hardware) the sum: (number of TGTBTS) + (number of TGTTDD) + (number of TGTFDD) must be <= 650, and at most 650 instances (0..649) can be created for all the three classes; in case of MPCC V8 (new hardware) the sum: (number of TGTBTS) + (number of TGTTDD) + (number of TGTFDD) must be <= 1500, and at most 1500 instances (0..1499) can be created for all the three classes. CREATE TGTTDD: NAME=TGTTDD:tgttddn ,CELLGLID= ,RNCID= ,BNDWIDTDD= ,TDDARFCN= ,TDDCPAR= ,TDDSYNCCAS= ,TDDDIV= [,MSTXPMAXUMTS=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_INVALID_ATTRIBUTES Two TGTTDD objects cannot have equal pair TDDARFCN - TDDSCRMC. The frequencies must be included in the range: 9262..9638, 9662..9938, 10062..10113. UNSUCCESSFUL_CELL_GLOB_ID All the fields of CELLGLID attribute must be set. Two TGTTDD objects cannot have equal pair RNCID - CELLGLID. A30808-X3247-L230-3-7619 1333 Commands Base Station Controller CML:BSC Example of Command Execution Create TGTTDD:NAME=TGTTDD:0,CELLGLID="123"-"45"-1-1, RNCID=40,BNDWIDTDD=MCPS384, TDDARFCN=9665, TDDCPAR=4, TDDSYNCCAS=SYNC2, TDDDIV=DIVERSITY, MSTXPMAXUMTS=9; DELETE TGTTDD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTTDD DELETE TGTTDD Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a previously created instance of the TGTTDD object class. The validity range of the object address "tgttddn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete TGTTDD:NAME=TGTTDD:0; GET TGTTDD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTTDD GET TGTTDD DELETE TGTTDD: NAME=TGTTDD:tgttddn; DELETE ACK: DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_SUBORDINATE_EQUIPPED The TGTTDD object instance cannot be deleted if is referenced as the target cell by any ADJC3G object instance. GET TGTTDD: NAME=TGTTDD:tgttddn [,REQATTL= CELLGLID, RNCID, BNDWIDTDD, TDDARFCN, TDDCPAR, TDDSYNCCAS, TDDDIV, MSTXPMAXUMTS]; 1334 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameter values of an instance of the TGTTDD object class. The validity range of the object address "tgttddn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get TGTTDD:NAME=TGTTDD:0,REQATTL=CELLGLID&RNCID&BNDWIDTDD& TDDARFCN&TDDCPAR&TDDSYNCCAS&TDDDIV&MSTXPMAXUMTS; GET TGTTDD BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTTDD GET TGTTDD BASICS Applicability: Phase 2. Visibility level 1. GET ACK: NAME: name CELLGLID: cellGlobalIdentity RNCID: rncId BNDWIDTDD: bandwidthTdd TDDARFCN: tddArfcn TDDCPAR: tddCellParameter TDDSYNCCAS: tddSyncCase TDDDIV: tddDiversity MSTXPMAXUMTS:msTxPwrMaxUmts GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET TGTTDD BASICS: NAME=TGTTDD:tgttddn; A30808-X3247-L230-3-7619 1335 Commands Base Station Controller CML:BSC Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "tgttddn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get TGTTDD BASICS:NAME=TGTTDD:0; SET TGTTDD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TGTTDD SET TGTTDD Applicability: Phase 2. Visibility level 2. Command Description: This command modifies the specific parameters of the TGTTDD object class. The validity range of the object address "tgttddn" can be found in Appendix A. GET TGTTDD BASICS ACK: NAME: name CELLGLID: cellGlobalIdentity RNCID: rncId BNDWIDTDD: bandwidthTdd TDDARFCN: tddArfcn TDDCPAR: tddCellParameter TDDSYNCCAS: tddSyncCase TDDDIV: tddDiversity MSTXPMAXUMTS:msTxPwrMaxUmts GET TGTTDD BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SET TGTTDD: NAME=TGTTDD:tgttddn [,CELLGLID=] [,RNCID=] [,BNDWIDTDD=] [,TDDARFCN=] [,TDDCPAR=] [,TDDSYNCCAS=] [,TDDDIV=] [,MSTXPMAXUMTS=]; 1336 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Set TGTTDD:NAME=TGTTDD:0,CELLGLID="123"-"45"-1-1, RNCID=40,BNDWIDTDD=MCPS384, TDDARFCN=9665, TDDCPAR=4, TDDSYNCCAS=SYNC2, TDDDIV=DIVERSITY,MSTXPMAXUMTS=49; SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. UNSUCCESSFUL_INVALID_ATTRIBUTES Two TGTTDD objects cannot have equal pair TDDARFCN - TDDSCRMC. The frequencies must be included in the range: 9262..9638, 9662..9938, 10062..10113. UNSUCCESSFUL_CELL_GLOB_ID Two TGTTDD objects cannot have equal pair RNCID - CELLGLID. A30808-X3247-L230-3-7619 1337 Commands Base Station Controller CML:BSC TRACE The TRACE object represents the object that controls the trace collection for the generation of the trace records. CREATE TRACE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRACE CREATE TRACE Applicability: Phase 2. Visibility level 2. Command Description: This command creates the object TRACE representing the system capability of performing the tracing of subscriber's activities when specific events occur within PLMN. The validity range of the object address "tracen" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Create TRACE:NAME=TRACE:0,RECCRI=NO_CRITERIA DELETE TRACE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRACE DELETE TRACE CREATE TRACE: NAME=TRACE:tracen [,RECCRI=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. DELETE TRACE: NAME=TRACE:tracen; 1338 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 2. Command Description: This command deletes the object TRACE, previously created. The validity range of the object address "tracen" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete TRACE:NAME=TRACE:0; GET TRACE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRACE GET TRACE Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameters of the TRACE object. The validity range of the object address "tracen" can be found in Appendix A. System Responses: DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a TRACE, the relative object instance must be in LOCKED state. GET TRACE: NAME=TRACE:tracen [,REQATTL=RECCRI]; GET ACK: NAME: name RECCRI: recordCriteria A30808-X3247-L230-3-7619 1339 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get TRACE:NAME=TRACE:0 GET TRACE BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRACE GET TRACE BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "tracen" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get TRACE BASICS:NAME=TRACE:0; GET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET TRACE BASICS: NAME=TRACE:tracen; GET TRACE BASICS ACK: NAME: name RECCRI: recordCriteria GET TRACE BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1340 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET TRACE STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRACE GET TRACE STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the TRACE object: Administrative State (AST) Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "tracen" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get TRACE STAT:NAME=TRACE:0; GETINFO TRACE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRACE GETINFO TRACE Applicability: Phase 2. Visibility level 2. GET TRACE STAT: NAME=TRACE:tracen GET TRACE STAT ACK: GET TRACE STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETINFO TRACE NAME=TRACE:tracen; A30808-X3247-L230-3-7619 1341 Commands Base Station Controller CML:BSC Command Description: This command is used to retrieve the whole set of information regarding the TRACE instance active in the system. The given information are organized as follows: 1. TRACE control identier and states: AST, OST, UST 2. Record criteria 3. For each active TRACE and last ve terminated traces the following information are given: TRACE reference, IMSI, current le size, TRACE type, start time and the list of the les already uploaded. The validity range of the object address "tracen" can be found in Appendix A. System Responses: GETINFO TRACE:NAME=TRACE:0; (* Replay of the BSC *) GET INFO REPORT: ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED USAGE STATE: ACTIVE RECORD CRITERIA: NO CRITERIA LIST OF ALL ACTIVE TRACES: TRACE REF: 0 IMSI NR: 555014400000047 CURRENT FILE SIZE: 3 KBYTES TRACE TYPE: 33 START TIME: 31-MAR-2000 16:43:59 TRACE REF: 1 IMSI NR: 555015600000047 CURRENT FILE SIZE: 2 KBYTES TRACE TYPE: 33 START TIME: 31-MAR-2000 16:44:00 TRACE REF: 6 IMSI NR: 556032600000042 CURRENT FILE SIZE: 2 KBYTES TRACE TYPE: 33 START TIME: 31-MAR-2000 16:45:00 LIST OF THE LAST 5 TERMINATED TRACES: 1342 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TRACE REF: 0 IMSI NR: 555014400000047 TRACE TYPE: 33 START TIME: 31-MAR-2000 16:43:59 STOP TIME: 31-MAR-2000 16:43:57 TRACE REF: 4 IMSI NR: 555015600000047 TRACE TYPE: 33 START TIME: 31-MAR-2000 16:44:00 STOP TIME: 31-MAR-2000 16:50:00 END OF REPORT GETINFO TRACE NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack TRACE: name = TRACE:0 nackCause = <nack cause> Application Guidelines: None. Example of Command Execution Getinfo TRACE:NAME=TRACE:0; LOCK TRACE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRACE LOCK TRACE NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another Getinfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 Getinfo commands already in progress. LOCK TRACE: NAME=TRACE:tracen; A30808-X3247-L230-3-7619 1343 Commands Base Station Controller CML:BSC Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "tracen" can be found in Appendix A. System Responses: Application Guidelines: 1. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 2. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock TRACE:NAME=TRACE:0; SHUTDOWN TRACE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRACE SHUTDOWN TRACE Applicability: Phase 2. Visibility level 1. Command Description: This command allows the graceful transition of an object from the administrative state "Unlocked" to the administrative state "Locked" after the object has terminated its current activity. If after the predefined period (5.5 minutes) the current activity is not terminated, the administrative state will be set at Locked. If one of the objects is still active or busy after the predefined period, ongoing calls will be dropped. LOCK TRACE ACK: LOCK TRACE NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SHUTDOWN TRACE: NAME=TRACE:tracen; 1344 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller The validity range of the object address "tracen" can be found in Appendix A. System Responses: Application Guidelines: 1. If the operator has started too many shutdown commands, the system will display the SM TOO BUSY message. 2. Possible state transitions and timing: a) UNLOCKED -immediately-> SHUTTING DOWN ---------- immediately ----------> LOCKED b) UNLOCKED -immediately-> SHUTTING DOWN ---------- 5 minutes ----------> LOCKED c) UNLOCKED -immediately-> SHUTTING DOWN ---------- after object went to idle state ----------> LOCKED The state changes described above show all the possible transitions when the shut- down command was performed. The timer is set at 5 minutes xed value. The rst column of the table gives the situations which are affected by doing a shutdown of an object. Example of Command Execution Shutdown TRACE:NAME=TRACE:0; SHUTDOWN TRACE ACK: SHUTDOWN TRACE NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SITUATIONS TRANSITIONS FORCED/NOT FORCED idle object a) busy object but not released after the SHUTDOWN command b) busy object but released after the SHUTDOWN command c) A30808-X3247-L230-3-7619 1345 Commands Base Station Controller CML:BSC UNLOCK TRACE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRACE UNLOCK TRACE Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "tracen" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock TRACE:NAME=TRACE:0; UPLALLIMSITR TRACE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRACE UPALLIMSITR TRACE Applicability: Phase 2. Visibility level 0. UNLOCK TRACE: NAME=TRACE:tracen; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UPLALLIMSITR TRACE: NAME=TRACE:tracen ,DESTDIR= ,OVERWRITE=; 1346 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command allows to upload, from BSC disk to LMT disk, the information related to the trace activities related to all cells. The validity range of the object address "tracen" can be found in Appendix A. System Responses: Application Guidelines: 1. If the scannerlogle is uploaded with OVERWRITE parameter set at NOand the le already exists on the LMT disk, the LMT renames the existing one to oldfilename_DayMonthYearHourMinute.Thesameextention and stores the uploaded one to the disk. 2. If the user aborts the upload command or the link (between LMT and BSC) falls down, then it is no more possible to upload the same le: a new measure le will be created until new log les will be produced inside BSC. Example of Command Execution UPLALLIMSITR TRACE:NAME=TRACE:0,DESTDIR="C:\Siemens\Trace", FILE="*.*",OVERWRITE=YES; UPLIMSITR TRACE Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRACE UPLIMSITR TRACE Applicability: Phase 2. Visibility level 0. Command Description: This command allows to upload, from BSC disk to LMT disk, the information related to the trace activities related the cell defined by means of the TRACEREF parameter. The validity range of the object address "tracen" can be found in Appendix A. System Responses: UPLALLIMSITR ACK: UPLALLIMSITR NACK: NACK CAUSES: DIRECTORY_NOT_FOUND FILE_NOT_FOUND UPLIMSITR TRACE: NAME=TRACE:tracen ,DESTDIR= ,OVERWRITE=, TRACEREF=; UPLIMSITR ACK: UPLIMSITR NACK: A30808-X3247-L230-3-7619 1347 Commands Base Station Controller CML:BSC Application Guidelines: 1. If the scannerlogle is uploaded with OVERWRITE parameter set at NOand the le already exists on the LMT disk, the LMT renames the existing one to oldfilename_DayMonthYearHourMinute.Thesameextention and stores the uploaded one to the disk. 2. If the user aborts the upload command or the link (between LMT and BSC) falls down, then it is no more possible to upload the same le: a new measure le will be created until new log les will be produced inside BSC. Example of Command Execution UPLIMSITR TRACE:NAME=TRACE:0,DESTDIR="C:\Trace",FILE="General", OVERWRITE=NO,TRACEREF=22; NACK CAUSES: DIRECTORY_NOT_FOUND FILE_NOT_FOUND 1348 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TRAU The TRAU (Transcoder and Rate Adapter Unit) object represents the transcoder connected to a certain BSC. The transcoder receives fromone side a 2 Mbit/s PCMline with 16 kbit/s channels (on the Asub interface) and fromthe other side four 2 Mbit/s PCM lines with 64 kbit/s channels. CREATE TRAU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU CREATE TRAU Applicability: Phase 2. Visibility level 2. Command Description: This command adds a TRAU object to the BSS and specifies its dedicated 2 Mbit PCM line. The validity range of the object address "traun" can be found in Appendix A. System Responses: CREATE TRAU: NAME=TRAU:traun ,PCMSN= ,EXPSWV= [,ALLCRIT=] [,SALUNAME=] ,TEI= [,ETFO=] [,TSYNC=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. SUPERORDINATE_NOTEQUIPPED Each TRAU is connected to BSC through a 2 Mbit PCMS line. As a consequence, the relevant PCMS and the rele- vant LPDLS (LAPD Link) managed object must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The PCMSN indicates the pcms number connected to the TRAU. The pcms must be the same on which the time slot of the LPDLS has been previously allocated. The timer TSYNC must be set longer than ALARMT2 (see LICD object). INCOMP_NESWLOAD_VS_MESSAGE The EXPSWV assigned to the TRAU is not handled by the SW version of BSC. A30808-X3247-L230-3-7619 1349 Commands Base Station Controller CML:BSC Application Guidelines: 1. After the creation of the object the ADMINISTRATIVE state of this object is set at LOCKED. An UNLOCK command is required to put this object in service. 2. In TD-SCDMA congurations, at least 2 TDCUs are needed to support more than 36 TRAUs. Example of Command Execution Create TRAU:NAME=TRAU:0,PCMSN=3,TSYNC=100, EXPSWV="01-00-01-01-04-04_95-03-01", ALLCRIT=NOT_COMPATIBLE_WITH_CROSSCONNECT, SALUNAME="AD042S7449F",TEI=2,ETFO=FALSE; DELETE TRAU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU DELETE TRAU Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a TRAU object in the BSS, previously created. The validity range of the object address "traun" can be found in Appendix A. System Responses: INVALID_SVR The attribute ALLCRIT cannot assume value COMPATIBLE_WITH_CROSS_CONNECT in case of PCM24 (see attribute PCMTYPE of BSC object). A TRAU with BR6.0 SW Version cannot have a value different from 01 or 02 in the fourth digit of EXPSWV attribute. A TRAU with BR7.0 SW Version cannot have a value different from 03 in the fourth digit of EXPSWV attribute. INVALID_SALES_UNIQUE_NAME If the SALUNAME is different fromNOT_DEFINED, it must be different from SALUNAME of the other equipped TRAUs. DELETE TRAU NAME=TRAU:traun; DELETE ACK: Successful DELETE NACK: DELETE NACK: UNSUCCESSFUL_OBJECT_NOTEQUIPPED 1350 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: No clock sychronization signal (SYNC) has to be derived fromthe PCMS line connected to TRAU. Example of Command Execution Delete TRAU:NAME=TRAU:5; GET TRAU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU GET TRAU Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameters of the TRAU object. The validity range of the object address "traun" can be found in Appendix A. System Responses: The object instance must be already equipped. SUBORDINATE_EQUIPPED No 2 Mbit PCM line on "A" interface has to be connected to TRAU. UNSUCCESSFUL_INVALID_STATUS Before deleting a TRAU, the relative object instance must be in LOCKED state. GET TRAU: NAME=TRAU:traun [,REQATTL=PCMSN, TSYNC, EXPSWV, ALLCRIT, SALUNAME, TEI, ETFO, TOPOREL]; GET ACK: NAME: name PCMSN: pcmsn TSYNC: tSync EXPSWV: expectedSwVersion ALLCRIT: tallocationCriteria SALUNAME: salesUniqueName TEI: tei ETFO: enableTFO TOPOREL: topologicalRelationship GET NACK: A30808-X3247-L230-3-7619 1351 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get TRAU:NAME=TRAU:0,REQATTL=PCMSN&TSYNC&EXPSWV& ALLCRIT&SALUNAME&TEI&ETFO&TOPOREL; GET TRAU BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU GET TRAU BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "traun" can be found in Appendix A. System Responses: Application Guidelines: None. NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET TRAU BASICS: NAME=TRAU:traun; GET TRAU BASICS ACK: NAME: name PCMSN: pcmsn TSYNC: tSync EXPSWV: expectedSwVersion ALLCRIT: tallocationCriteria SALUNAME: salesUniqueName TEI: tei ETFO: enableTFO TOPOREL: topologicalRelationship GET TRAU BASICS NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1352 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Get TRAU BASICS:NAME=TRAU:0; GET TRAU STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU GET TRAU STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the TRAU object: Administrative State (AST) Operational State (OST) Usage State (UST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Unknown Status (UNK). The validity range of the object address "traun" can be found in Appendix A. System Responses: Application Guidelines: Only sets with raised bits are shown. Example of Command Execution Get TRAU STAT:NAME=TRAU:0; GET TRAU TIMER GET TRAU STAT: NAME=TRAU:traun; GET TRAU STAT ACK: GET TRAU STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GET TRAU TIMER: NAME=TRAU:traun; A30808-X3247-L230-3-7619 1353 Commands Base Station Controller CML:BSC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU GET TRAU TIMER Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the TIMER group. The validity range of the object address "traun" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get TRAU TIMER:NAME=TRAU:0; GETINFO TRAU Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT TRAU GETINFO TRAU Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The OSU running object and the OSU version. 2. The TRAU name. 3. A transcoder matrix for each of the TRAU pcms timeslots: the number of subslots, the PCMA number and the TSLA number. 4. The allocation criteria used. 5. The number of trafc channels which are really transcoded. 6. The TSYNC time. 7. Synchronization source; values: BSC or MSC. GET TRAU TIMER ACK: GET TRAU TIMER NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETINFO TRAU: NAME=TRAU:traun; 1354 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 8. The synchronization line (that is the PCMT line), but only if the SYNCsource is MSC. 9. The congured transparent channels (SS7L, X25A). 10. The PCMA lines connected with the TRAU. 11. For each equipment object of TRAU the states and statuses: AST, OST, STNDBYST. 12. A transcoder matrix for each of the TRAU pcms timeslots: the number of subslots, the PCMA number and the TSLA number. The validity range of the object address traun can be found in Appendix A. System Responses: GETINFO TRAU ACK: BSC_CONTROLLER -> LMT_LOCAL 11:41:14 22/03/1999 *** INFORMATION *** GET INFO REPORT: NAME = TRAU:0 OSU: TRAUEOSUSW 0 ESU RUNNING VERSION: 02-06-01-01-00-00_00-01-10 SALES UNIQUE NAME: VOGHERA ALLOCATION CRITERIA: < 0 -> NOT_COMPATIBLE_WITH_CROSSCONNECT, 1 -> COMPATIBLE_WITH_CROSSCONNECT > NR. OF TRANSCODED CHANNELS: 27 TSYNC: 0200 SYNC SOURCE: MSC SYNC LINE: 0 SS7L TIMESLOT: 2-4 21-30 (PCM NR-TS NR) X25A TIMESLOT: 10-5 (PCM NR-TS NR) PCMA CONNECTED: 2 10 21 OBJECT ADMINISTRATIVE OPERATIONAL STANDBY TPWR 0 UNLOCKED DISABLED NONE TPWR 1 UNLOCKED ENABLED NONE BSMS 0 UNLOCKED ENABLED HOT_STANDBY BSMS 1 UNLOCKED ENABLED PROVIDING_SERVICE TRAC 0 UNLOCKED ENABLED COLD_STANDBY TRAC 1 UNLOCKED ENABLED PROVIDING_SERVICE ... ... A30808-X3247-L230-3-7619 1355 Commands Base Station Controller CML:BSC TRAC 5 UNLOCKED DISABLED NONE TSLS NR. TSLSUB NR PCMA NR TSLA NR 1 0 1 1 1 1 1 2 1 3 1 0 2 1 2 2 2 3 3 0 3 1 3 2 3 3 4 0 4 1 1 4 4 2 4 3 5 0 5 1 5 2 5 3 6 0 6 1 1 6 6 2 6 3 7 0 7 1 7 2 7 3 8 0 8 1 1 8 8 2 8 3 9 0 9 1 9 2 9 3 1356 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 10 0 10 1 10 2 10 3 11 0 11 1 1 11 11 2 11 3 12 0 12 1 1 12 12 2 12 3 13 0 13 1 1 13 13 2 13 3 14 0 14 1 1 14 14 2 14 3 15 0 15 1 15 2 15 3 16 0 16 1 1 16 16 2 16 3 17 0 17 1 1 17 17 2 17 3 18 0 18 1 1 18 18 2 18 3 19 0 19 1 1 19 19 2 A30808-X3247-L230-3-7619 1357 Commands Base Station Controller CML:BSC 19 3 20 0 20 1 20 2 20 3 21 0 21 1 1 21 21 2 21 3 22 0 22 1 1 22 22 2 22 3 23 0 23 1 1 23 23 2 23 3 24 0 24 1 1 24 24 2 24 3 25 0 25 1 1 25 25 2 25 3 26 0 26 1 1 26 26 2 26 3 27 0 27 1 1 27 27 2 27 3 28 0 28 1 1 28 28 2 28 3 29 0 29 1 1 29 1358 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 29 2 29 3 30 0 30 1 30 2 30 3 31 0 31 1 31 2 31 3 END OF REPORT GETINFO TRAU NACK: BSC_CONTROLLER -> LMT_LOCAL 16:24:45 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack TRAU: name = TRAU:0 nackCause = <nack cause> Application Guidelines: 1. The sequence of the HWobjects will not necessarily be in an alphabetical order and only the equipped instances will be reported. 2. TSYNC is an attribute of the TRAU object (see TRAU object). Example of Command Execution Getinfo TRAU:NAME=TRAU:0; GETRELATIONSHIP TRAU NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another GetInfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 GetInfo commands already in progress. GETRELATIONSHIP TRAU: NAME=TRAU:traun; A30808-X3247-L230-3-7619 1359 Commands Base Station Controller CML:BSC Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU GETRELATIONSHIP TRAU Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of the all HMOs (Hardware Managed Object) supporting the FMO functionality. For the TRAU object the related HMOs are the following: LICD/LICDS, EPWR, BSMS, TPWR, PPLD, PWRD, MPCC, TDPC, MEMT, NTW and PPXL. The validity range of the object address "traun" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship TRAU:NAME=TRAU:0; GETSUBO TRAU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU GETSUBO TRAU Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. The validity range of the object address "traun" can be found in Appendix A. GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. GETSUBO TRAU: NAME=TRAU:traun; 1360 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Getsubo TRAU:NAME=TRAU:0; LOCK TRAU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU LOCK TRAU Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". The validity range of the object address "traun" can be found in Appendix A. System Responses: Application Guidelines: 1. If object TRX or CHAN is locked, calls using the concerned objects are dropped. To avoid loss of calls by locking objects TRX or CHAN a request for usage state of this GETSUBO TRAU ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end there a message is displayed noti- fying the end of the subordinate list. GETSUBO TRAU NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK TRAU: NAME=TRAU:traun; LOCK TRAU ACK: LOCK TRAU NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1361 Commands Base Station Controller CML:BSC objects should be done previously (e.g. GET state status). In case returned usage state is "active" or "busy" locking should not be done (otherwise calls are dropped). 2. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 3. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock TRAU:NAME=TRAU:0; SET TRAU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU SET TRAU Applicability: Phase 2. Visibility level 2. Command Description: This command modifies the attributes of the TRAU object. The validity range of the object address "traun" can be found in Appendix A. System Responses: SET TRAU: NAME=TRAU:traun [,EXPSWV=] [,SALUNAME=] [,ETFO=] [,TSYNC=]; SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. INCOMP_NESWLOAD_VS_MESSAGE The EXPSWV assigned to the TRAU is not handled by the SW version of BSC. INVALID_SALES_UNIQUE_NAME If the SALUNAME is different from NOT_DEFINED, it must be different from SALUNAME of the other equipped TRAUs. UNSUCCESSFUL_INVALID_STATUS In order to set the ETFO (Enable TFO) parameter, the related TRAU must be in the administrative state LOCKED. TRAU SW Version cannot be changed by means of the EXPSWV attribute if the TRAU object instance is not in the administrative state LOCKED. 1362 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. TSYNC should be equal with TSYNC of the BTS object. 2. The timer TSYNC must be set longer than ALARMT2 (see LICD object). Example of Command Execution Set TRAU:NAME=TRAU:0,TSYNC=10,EXPSWV=01-00-01-01-04-04_95-03-01, SALUNAME=AD042S7449F; SHUTDOWN TRAU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU SHUTDOWN TRAU Applicability: Phase 2. Visibility level 1. Command Description: This command allows the graceful transition of an object from the administrative state "Unlocked" to the administrative state "Locked" after the object has terminated its current activity. The systemattempts to performthe command every 10 seconds for the next 6 minutes. If after the predefined period (5.5 minutes) the current activity is not terminated, the administrative state will be set at Locked. If one of the objects is still active or busy after the predefined period, ongoing calls will be dropped. The validity range of the object address "traun" can be found in Appendix A. System Responses: INVALID_SVR A TRAU with BR6.0 SWVersion cannot have a value different from 01 or 02 in the fourth digit of EXPSWV attribute. A TRAU with BR7.0 SWVersion cannot have a value different from 03 in the fourth digit of EXPSWV attribute. SHUTDOWN TRAU: NAME=TRAU:traun; SHUTDOWN TRAU ACK: SHUTDOWN TRAU NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1363 Commands Base Station Controller CML:BSC Application Guidelines: 1. If the operator has started too many shutdown commands, the system will display the SM TOO BUSY message. 2. Possible state transitions and timing: a) UNLOCKED -immediately-> SHUTTING DOWN ---------- immediately ----------> LOCKED b) UNLOCKED -immediately-> SHUTTING DOWN ---------- 6 minutes and 10 seconds ----------> LOCKED c) UNLOCKED -immediately-> SHUTTING DOWN ---------- after object went to idle state ----------> LOCKED The state changes described above show all the possible transitions when the shut- down command was performed. The rst column of the table gives the situations which are affected by doing a shutdown of an object. Example of Command Execution Shutdown TRAU:NAME=TRAU:1; UNLOCK TRAU Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU UNLOCK TRAU Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". The validity range of the object address "traun" can be found in Appendix A. System Responses: SITUATIONS TRANSITIONS FORCED/NOT FORCED idle object a) busy object but not released after the SHUTDOWN command b) busy object but released after the SHUTDOWN command c) UNLOCK TRAU: NAME=TRAU:traun; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE 1364 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Unlock TRAU:NAME=TRAU:0; The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1365 Commands Base Station Controller CML:BSC TRAUOSUSW The TRAUOSUSW (TRAU Operating Software Unit SW) is used to represent the operating software resource for TRAU; the OSUobjects are used to identify which ESUs (Executable Software Unit) are operational. GET TRAUOSUSW Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU TRAUOSUSW GET TRAUOSUSW Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of the parameters selected by the operator by means of the REQATTL correspondent list. Validity ranges of the object addresses traun and trauosuswn can be found in Appendix A. System Responses: GET TRAUOSUSW NAME=TRAU:traun/TRAUOSUSW:trauosuswn [,REQATTL=RUNESU, BCKUPESU, PH]; GET ACK: NAME: name RUNESU: runningESU BCKUPESU: backupESU PH: phase GET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK This command is rejected due to an internal subsystem abort. 1366 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get TRAUOSUSW:NAME=TRAU:0/TRAUOSUSW:0,REQATTL=RUNESU& BCKUPESU&PH; GET TRAUOSUSW BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU TRAUOSUSW GET TRAUOSUSW BASICS Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the values of all the TRAUOSUSW parameters. Validity ranges of the object addresses traun and trauosuswn can be found in Appendix A. System Responses: Application Guidelines: None. GET TRAUOSUSWBASICS NAME=TRAU:traun/TRAUOSUSW:trauosuswn; GET ACK: NAME: name RUNESU: runningESU BCKUPESU: backupESU PH: phase GET NACK: NACK CAUSES: NO_ADMITTED_OPERATION Waiting for SDSM server activation. NO_TASKS_AVAILABLE No free servers are available to perform the command. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. OBJECT_NOT_FOUND The referenced object instance does not exist. ABORT_BY_SYSTEM_NCK An internal system abort is occurred. A30808-X3247-L230-3-7619 1367 Commands Base Station Controller CML:BSC Example of Command Execution Get TRAUOSUSW BASICS:NAME=TRAU:0/TRAUOSUSW:0; GETINFO TRAUOSUSW Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU TRAUOSUSW GETINFO TRAUOSUSW Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information about the running and the backup SW version (all together) for a TRAU network element. The information recovered are: 1. For each NEYESUSW corresponding to runningESU attribute: NEYESUSW instance identier, User label associated, Version number, Operational state; 2. For each NEYESUSW corresponding to backupESU attribute: NEYESUSW instance identier, User label associated, Version number, Operational state; 3. Information about the load usage state. The validity range of the object address trauosuswn can be found in Appendix A. System Responses: GETINFO TRAUOSUSW ACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** INFORMATION *** GETINFO REPORT TRAUOSUSW: NAME = TRAUOSUSW:1 RUNNING ESU INSTANCE: 0 USER LABEL: 62TRAUAS0024 VERSION: 02-06-02-01-00-24_01-12-19 OPERATIONAL STATE: DISABLED GETINFO TRAUOSUSW NAME=TRAU:traun/TRAUOSUSW:trauosuswn; 1368 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BACKUP ESU INSTANCE: 0 USER LABEL: 62BSCHB010024 VERSION: 02-06-02-01-00-24_01-12-19 OPERATIONAL STATE: ENABLED LOAD USAGE STATE: IDLE END OF REPORT GETINFO TRAUOSUSW NACK: BSC_CONTROLLER -> LMT_LOCAL 16:21:29 22/09/1998 *** RESPONSE TO JOB 1 *** Get Info Report Nack TRAUOSUSW: name = TRAUOSUSW:1 nackCause = <nack cause> Application Guidelines: None. Example of Command Execution Getinfo TRAUOSUSW:NAME=TRAU:0/TRAUOSUSW:1; SETRUNBACK TRAUOSUSW Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL TRAU TRAUOSUSW SETRUNBACK TRAUOSUSW Applicability: Phase 2. Visibility level 2. NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another GetInfo on the input object is already in progress. T_RESOURCE_NOT_AVAILABLE If there are 10 GetInfo commands already in progress. SETRUNBACK TRAUOSUSW NAME=TRAU:traun/TRAUOSUSW:trauosuswn; A30808-X3247-L230-3-7619 1369 Commands Base Station Controller CML:BSC Command Description: This command allows the user to perform a run-back procedure: load of the TRAUOSUSW object from OSUSW backupESU object. The validity range of the object address trauosuswn can be found in Appendix A. System Responses: Application Guidelines: The OperationalState attribute of the specific TRAUESUSWmust be ENABLED. If the precondition is not satisfied and/or if the dbVersion required is not stored on BSC disk, then a specific error collector call is performed. Example of Command Execution Setrunback TRAUOSUSW:NAME=TRAU:0/TRAUOSUSW:0; SETRUNBACK ACK: SETRUNBACK NACK: NACK CAUSES: ABORT_BY_SYSTEM_NCK An internal system abort is occurred. OBJECT_NOT_FOUND The referenced object instance does not exist. INVALID_PARAMETER_NCK The involved NE attribute does not exist. The input parameter is out of range. OBJECT_ALREADY_IN_USE The command clashes with another one already in progress. INCONSISTENT_STATE_NCK NE activation time-out is expired. INITIALIZATION_IN_PROGRESS_NCK An initialization of the system is in progress. UNSUCCESSFUL_SYS_CALL A system function call is failed. UNSUCCESSFUL_OBJ_NOTEQUIPPED NE is not equipped. EXPECTED_SWVER_UNDEFINED_NCK Expected SW version is not defined for NE. PROCESSING_ERROR_NCK A function call (for example allocation of memory) fails. UNSUCCESSFUL_LINK_NOT_AVAIL The link with NE is not activated. DOWNLOAD_ALREADY_IN_PROGRESS_NCK A download of the same NE is already in progress. 1370 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TRX The TRX (Transceiver) object locates the transceivers connected to a certain BSC. CREATE TRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC BTS TRX CREATE TRX Applicability: Phase 2. Visibility level 2. Command Description: This command defines the global parameters of the Transceiver (TRX) for the TRX dedicated to both traffic and BCCH functions. Validity ranges of the object addresses btsmn, "btsn" and "trxn" can be found in Appendix A. System Responses: CREATE TRX: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn ,TRXFREQ= [,PWRRED=] [,RADIOMR=] [,RADIOMG=] [,MOEC=] [,TRXAREA=] ,LPDLMN= [,GSUP=] [,TRXMD=]; CREATE ACK: Successful CREATE NACK NACK CAUSES: UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The GSUP can be set at TRUE only if the related PTPPKF is already equipped. UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the TRX managed object must not be already equipped. UNSUCCESSFUL_VAR_OUT_OF_RANGE The maximum number of TRXs per BSS is 500. UNSUCCESSFUL_FREQUENCY_NOT_BELONG_TO_CEL The carrier frequency (TRXFREQ) of the TRX must belong to the set of frequencies assigned to the cell. UNSUCCESSFUL_FREQ_BELONG_TO_ANOTHER_TRX The carrier frequency (TRXFREQ) of the TRX must not be already assigned to another TRX belonging to the same BTS. UNSUCCESSFUL_NO_MORE_FREQ_AVAILABLE The number of available carrier frequencies (set in the CALLF<nn> parameters of the BTS object) has been already reached. A30808-X3247-L230-3-7619 1371 Commands Base Station Controller CML:BSC UNSUCCESSFUL_INVALID_TRX_AREA The attribute TRXAREA cannot be set at NONE value if the CONCELL parameter (see BTS object) is set at TRUE. The attribute TRXAREA cannot be set at INNER/COMPLETE values if the CONCELL parameter (see BTS object) is set at FALSE. The attribute TRXAREA cannot be set at INNER value on the TRX with broadcast functions. In a GSM850DCS concentric cell, all the TRXs belonging to the same band have to belong to the same area (inner or complete). In a GSMDCS or GSM850DCS concentric cell, the GSUP parameter of TRX object can be set at TRUE only if the carrier frequency of the TRX belongs to the same band of BCCH frequency. In case of EXT900, all the TRXs for which the GSUP is set at TRUE must belong to the same band of BCCH frequency. In case of F2ONLY, if the BCCH belongs to BB900 band, all the TRXs for which the GSUP is set at TRUE must belong to the BB900 band. In case of concentric cells all the TRXs for which the GSUP is set at TRUE must always belong to the complete area. UNSUCCESSFUL_INVALID_STATUS Before creating a TRX, the RFLOOP object instance relative to the BTS which the TRX belongs to must be in the administrative state LOCKED. UNSUCCESSFUL_LINK_NOT_AVAIL In case of NTWCARD different fromNTWSNAP, there are no more TEIs available. UNSUCCESSFUL_EXCEED_OBJECT_NBR If the BTSMis a BS-240XS, it is not possible to create for each subordinate BTS a TRX number greater than 2. If the BTSMis a BS-240XS, it is not possible to create for each BTSM a TRX number greater than 6. UNSUCCESSFUL_INVALID_ATTRIBUTES The attribute TRXMD can not be set at EDGE if GSUP attribute is set at FALSE. The attribute GSUP can not be set at FALSE if TRXMD attribute of current TRX is set at EDGE. UNSUCCESSFUL_EDGE_NOT_SUPPORTED The attribute TRXMD can not be set at EDGE if ESUP attribute of BSC object is set at FALSE. UNSUCCESSFUL_EDGE_ENABLED The attribute TRXMD can not be set at GSM if EEDGE attribute of related PTPPKF object is set at TRUE and none of remaining TRXs in the cell has TRXMD set at EDGE. UNSUCCESSFUL_EDGE_ON_BCCH_AVAILABLE The attribute TRXMD (of BCCH TRX) can not be set at GSM if EBCCHTRX is set at TRUE. 1372 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. If the transceiver carrier frequency corresponds to the frequency indicated by the BCCHFREQ parameter (previously set at the creation of the BTS managed object), then it is assumed that the transceiver is the broadcast one. 2. After the creation of the object the ADMINISTRATIVE state of this object is set at LOCKED. An UNLOCK command is required to put this object in service. 3. For concentric cells, the PWRRED parameter of the TRXs belonging to the inner area should be set at a value different from 0. 4. If only one 64 kbit/s LAPD channel is created in BSC and BTSE, the number of full rate and half rate TRXs to be congured is limited and might be lower than the maximum possible of 24 TRXs, in order not to increase the Call Failure Rate (the expression half(full) rate TRXs only means how many TRXs would be covered if the HR(FR) channels were on the same TRXs; the intention is to have a practical and not too detailed result). The maximum allowed number of congured full rate and half rate TRXs can be estimated according to the following rule: 2 * (number of half rate TRXs) + (number of full rate TRXs) <= 32. This rule is valid only if no radio measurements are activated within a BTSM. If two or more 64 kbit/s LAPD channels are created there is no limitation for the number of congured TRXs. 5. Special care has to be applied if the RADIOMR attribute is set at ON for several TRXs. For more details see Appendix B: Group 8. Example of Command Execution Create TRX:NAME=BTSM:0/BTS:0/TRX:0,TRXFREQ=CALLF02,PWRRED=0, RADIOMR=ON,RADIOMG=2,MOEC=TRUE,TRXAREA=NONE,LPDLMN=0, GSUP=FALSE,TRXMD=GSM; INCOMP_NESWLOAD_VS_MESSAGE The attribute TRXMD can not be set at EDGE if the SW Version running on the superordinated BTSM object belongs to BR6.0 release (see EXPSWV parameter description). The attribute TRXMD can not be set at EDGE if the BTSE is not a BTS+. UNSUCCESSFUL_GPRS_ENABLED The attribute GSUP can not be set at FALSE if EGPRS is set at TRUE and none of remaining TRXs in the cell has GSUP set at TRUE. UNSUCCESSFUL_EXCEED_OBJECT_NBR With MPCCV7 board or old BSC rack type, no more than 500 TRX instances can be created in the whole BSC. A30808-X3247-L230-3-7619 1373 Commands Base Station Controller CML:BSC DELETE TRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX DELETE TRX Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a previously created TRX. Validity ranges of the object addresses btsmn, "btsn" and "trxn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete TRX:NAME=BTSM:0/BTS:0/TRX:0; DELETE TRX: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a TRX, the relative object instance must be in LOCKED state. Before deleting a TRX, the RFLOOP object instance configured in the cell which the TRX belongs to must be in LOCKED state. Before deleting a TRX, the SCA object instance configured in the cell which the TRX belongs to must be in LOCKED state. UNSUCCESSFUL_DEL_ALL_CHAN_BEFORE Before deleting a TRX object instance it is necessary to delete all the channels belonging to the involved TRX. UNSUCCESSFUL_HOPP_TRX In case of base band frequency hopping, the TRX carrier frequency must not be assigned to any FHSY instance. 1374 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET TRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX GET TRX Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameters of a previously created TRX. Validity ranges of the object addresses btsmn, "btsn" and "trxn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get TRX:NAME=BTSM:0/BTS:0/TRX:0,REQATTL=TRXFREQ&PWRRED& BCCHTRX&RADIOMR&RADIOMG&MOEC&TRXAREA&TEI&LPDLMN& TRXFREQV&GSUP&TRXMD; GET TRX: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn [,REQATTL= TRXFREQ, PWRRED, BCCHTRX, RADIOMR, RADIOMG, MOEC, TRXAREA, TEI, LPDLMN, TRXFREQV, GSUP, TRXMD]; GET ACK: TRXFREQ: carrierFrequency PWRRED: txPwrMaxReduction BCCHTRX: bcchTransceiver RADIOMR: radioMeasRep RADIOMG: radioMeasGran MOEC: MemberOfEmergencyConfig TEI:tei TRXAREA: trxArea LPDLMN:lapdmNumber TRXFREV:carrierFrequencyValue GSUP:gprsSupported TRXMD:trxMode GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1375 Commands Base Station Controller CML:BSC GET TRX BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX GET TRX BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses btsmn, "btsn" and "trxn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get TRX BASICS:NAME=BTSM:0/BTS:0/TRX:0; GET TRX BASICS: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn; GET TRX BASICS ACK: TRXFREQ: carrierFrequency PWRRED: txPwrMaxReduction BCCHTRX: bcchTransceiver RADIOMR: radioMeasRep RADIOMG: radioMeasGran MOEC: MemberOfEmergencyConfig TEI:tei TRXAREA: trxArea LPDLMN:lapdmNumber TRXFREV:carrierFrequencyValue GSUP:gprsSupported TRXMD:trxMode GET TRX BASICS NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. 1376 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET TRX STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX GET TRX STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the TRX object: Administrative State (AST) Operational State (OST) Usage State (UST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Unknown Status (UNK). Validity ranges of the object addresses btsmn, "btsn" and "trxn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get TRX STAT:NAME=BTSM:0/BTS:0/TRX:0; GET TRX STAT: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn; GET TRX STAT ACK: GET TRX STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1377 Commands Base Station Controller CML:BSC GETINFO TRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX GETINFO TRX Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The report complete indication. 2. The states and statuses of the TRX: AST, OST, UST, AVS, PRS. 3. The TRX absolute number. 4. The TRX capability (UNKNOWN, GSM, EDGE). 5. The TRX mode (GSM, EDGE). 6. The GPRS support (Yes or No). 7. The AntennaHopping Period used. 8. The Antenna Hw list. 9. For each channel of the TRX the type, the pool type, the usage mode and the states and statuses (AST, OST, UST, AVS), the used modality and the list of connected SUBTSLBs. Validity ranges of the object addresses btsmn, "btsn" and "trxn" can be found in Appendix A. System Responses: GETINFO TRX ACK: BSC_CONTROLLER -> LMT_LOCAL 11:41:14 22/03/1999 *** INFORMATION *** GET INFO REPORT TRX: NAME = TRX:0 REPORT COMPLETE: TRUE ADMINISTRATIVE STATE UNLOCKED OPERATIONAL STATE ENABLED USAGE STATE IDLE AVAILABILITY STATUS DEPENDENCY PROCEDURAL STATUS NONE TRX ABSOLUTE NR: 5 GETINFO TRX: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn; 1378 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TRX CAPABILITY: GSM TRX MODE: EDGE GPRS SUPPORTED: TRUE CONFIGURED ANTENNA HOPPING PERIOD: EVERY FOURTH FRAME ANTENNAS LIST (max 23 instances): DUVSWR 0-0 DUVSWR 0-1 DUVSWR 0-2 CHAN 0 TYPE TSC_DH POOL TYPE SDCCH_POOL USAGE MODE MODE_SDCCH ADMINISTRATIVE UNLOCKED OPERATIONAL ENABLED USAGE IDLE AVAILABILITY NONE MODE PACKED CONNECTED ABIS 12-15-0 12-15-1 12-15-2 13-4-0 CHAN 1 TYPE FULL_AND_HALF POOL TYPE NOT_DEFINED USAGE MODE NOT_APPLICABLE ADMINISTRATIVE UNLOCKED OPERATIONAL ENABLED USAGE BUSY AVAILABILITY NONE MODE PACKED CONNECTED ABIS 13-4 ... CHAN 7 TYPE FULL_AND_HALF POOL TYPE NOT_DEFINED USAGE MODE NOT_APPLICABLE ADMINISTRATIVE UNLOCKED OPERATIONAL ENABLED USAGE IDLE AVAILABILITY NONE A30808-X3247-L230-3-7619 1379 Commands Base Station Controller CML:BSC MODE NO_DEDICATED CONNECTED ABIS 13-4 END OF REPORT GETINFO TRX NACK: BSC_CONTROLLER -> LMT_LOCAL 16:24:45 22/09/1998 *** RESPONSE TO JOB 1*** Get Info Report Nack TRX: NAME = TRX:0 nackCause = <nack cause> Application Guidelines: None. Example of Command Execution Getinfo TRX:NAME=BTSM:0/BTS:0/TRX:0; GETRELATIONSHIP TRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX GETRELATIONSHIP TRX Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of the all HMOs (Hardware Managed Object) supporting the FMO functionality. For the TRX object the related HMOs are the following: EPWR, LICD, LICDS, PPLD, PWRD, MPCC, TDPC, MEMT, NTW and all the BTSE HMOs that implement the TRX functionality for a certain BTS. NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another GetInfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 GetInfo commands already in progress. GETRELATIONSHIP TRX: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn; 1380 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller For BS-2x/6x, the BTSE HMOs are: ACOM, BBSIG, CCLK, CCTRL, FTNF, FVSWR, GPSU, LI, PA, RXMUCO, RXAMOD and TPU. For BS-4x/240/241/240XL, the BTSEHMOs are: COBA, COSA, CU, DIDCTMA, DILNA, DUDCTMA, DULNA, DUVSWR, FTNFP, FVSWRP and TMA. For BS-242, the BTSE HMOs are: CA, CCINT, CCSLINK, COBA, COSA and DCREFE. For the BS-82, the BTSE HMOs are: COBA, CU, DUVSWR and DULNA. In case of a switched beam cell the attribute relatedEquipObjects shall include the new HMOs SDUSEC, SDUSUBSEC, SDUTXSW and SDULNA. Validity ranges of the object addresses btsmn, "btsn" and "trxn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship TRX:NAME=BTSM:0/BTS:0/TRX:0; GETSUBO TRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX GETSUBO TRX Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. Validity ranges of the object addresses btsmn, "btsn" and "trxn" can be found in Appendix A. GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. GETSUBO TRX: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn; A30808-X3247-L230-3-7619 1381 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Getsubo TRX:NAME=BTSM:0/BTS:0/TRX:0; LOCK TRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX LOCK TRX Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". Validity ranges of the object addresses btsmn, "btsn" and "trxn" can be found in Appendix A. System Responses: Application Guidelines: 1. If object TRX or CHAN is locked, calls using the concerned objects are dropped. To avoid loss of calls by locking objects TRX or CHAN a request for usage state of this GETSUBO TRX ACK: The output of the command can be composed by one or more pack with a maximumnumber of ten subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GETSUBO TRX NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK TRX: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn; LOCK TRX ACK: LOCK TRX NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1382 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller objects should be done previously (e.g. GET state status). In case returned usage state is "active" or "busy" locking should not be done (otherwise calls are dropped). 2. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 3. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). 4. In case of lock of TRX: a substitute TRX of the same BTS is chosen according to following conditions (if the 1st condition is not available, the following one is chosen): TRX with only TCH; TRX with TCHs & 1 SDCCH; TRX with TCHs & 1 SCBCH; TRX with BCCH, MBCCHC, BCBCH. Example of Command Execution Lock TRX:NAME=BTSM:0/BTS:0/TRX:0; SET TRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX SET TRX Applicability: Phase 2. Visibility level 2. Command Description: This command modifies the global parameters of the Transceiver (TRX) for the TRX dedicated to both traffic and BCCH function. Validity ranges of the object addresses btsmn, "btsn" and "trxn" can be found in Appendix A. System Responses: SET TRX: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn [,TRXFREQ=] [,PWRRED=] [,RADIOMR=] [,RADIOMG=] [,MOEC=] [,TRXAREA=] [,GSUP=] [,TRXMD=]; SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The GSUP can be set at TRUE only if the related PTPPKF is already equipped. UNSUCCESSFUL_SUBORDINATE_EQUIPPED The GSUP can be set at FALSE only when there are no GPRS channels on that TRX (PBCCH, PCCCH). A30808-X3247-L230-3-7619 1383 Commands Base Station Controller CML:BSC UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_FREQUENCY_NOT_BELONG_TO_CEL The carrier frequency (TRXFREQ) of the TRX must belong to the set of frequencies assigned to the cell. UNSUCCESSFUL_FREQ_BELONG_TO_ANOTHER_TRX The carrier frequency (TRXFREQ) of the TRX must not be already assigned to another TRX belonging to the same BTS. UNSUCCESSFUL_INVALID_BCCH_FREQUENCY If the TRX is the broadcast one, then its carrier frequency must be equal to the frequency that has been configured as BCCHFREQ in the BTS (see BTS object). UNSUCCESSFUL_INVALID_STATUS Make reference to APPLICATION GUIDELINES n. 1, n. 4, n. 12, n. 13. UNSUCCESSFUL_VAR_OUT_OF_RANGE In case of EXT900 frequency band, if the TRX has some signalling channels subordinated then the carrier frequency must be in the range 1..124. UNSUCCESSFUL_HOPP_TRX In case of base band frequency hopping, the old carrier frequency cannot be assigned to a FHSY instance. UNSUCCESSFUL_INVALID_TRX_AREA Make reference to APPLICATION GUIDELINES n. 2, n. 3, n. 5, n. 6, n. 7, n. 9, n. 11, n. 14. FREQUENCY_NOT_ALLOWED In case of synthesizer frequency hopping, the new carrierFrequency cannot be already used by any equipped frequency hopping systems. GPRS_TSC_INCONSISTENT All the traffic channels subordinate to a TRX with GSUP set at TRUE must have the same TSC. GPRS_HOPP_INCONSISTENT If the TRX has the GSUP set at TRUE single TCHs must have the same FHSYD and MAIO and if one or more CCCHs have already been equipped, the channels cannot hop (i.e. FHSYD attribute must be 0). UNSUCCESSFUL_INVALID_ATTRIBUTES The attribute TRXMD can not be set at EDGE if GSUP attribute is set at FALSE. The attribute GSUP can not be set at FALSE if TRXMD attribute of current TRX is set at EDGE. UNSUCCESSFUL_EDGE_NOT_SUPPORTED The attribute TRXMD can not be set at EDGE if ESUP attribute of BSC object is set at FALSE. UNSUCCESSFUL_EDGE_ENABLED The attribute TRXMD can not be set at GSM if EEDGE attribute of related PTPPKF object is set at TRUE and none of remaining TRXs in the cell has TRXMD set at EDGE. 1384 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. Before setting the value of the TRXFREQ parameter, the TRX object must be LOCKED. 2. The attribute TRXAREA cannot be set at the NONE value if the CONCELL parameter (see BTS object) is set at TRUE. 3. The attribute TRXAREA cannot be set at the INNER/COMPLETE values if the CONCELL parameter (see BTS object) is set at FALSE. 4. The attribute TRXAREA cannot be changed if the TRX is not in LOCKED status. 5. The attribute TRXAREA cannot be set at the INNER value on the TRX with broadcast functions. 6. The attribute TRXAREA cannot be set at the INNER value if there are subordinated SDCCH channels on the TRX. 7. The attribute TRXAREA cannot be changed (from INNER to COMPLETE and vice versa) if the frequency congured as TRXFREQ is used by frequency hopping and the base band hopping is selected. 8. For the concentric cell it is suggested to set all the txPwrMaxReduction of the inner or complete area at the same value. 9. In a GSMDCS or GSM850DCS concentric cell, all the TRXs belonging to the same band have to belong to the same area (inner or complete). In a GSMDCS concentric cell it is not possible to change the TRXAREA of a transceiver. This is due to the fact that in mixed cells to change the TRXAREA will mean to change the band of the TRX and this cannot be allowed because the HW of a TRX is not able to manage two different frequency bands. 10. In order to create a TRX the RFLOOP relative to the BTS which the TRX belongs to must be set at the administrative state LOCKED. 11. In case of concentric cells all the TRXs for which the GSUP is set at TRUE must always belong to the complete area. 12. In order to set the GSUP attribute all the subordinate TCHs must be in LOCKED state. 13. In order to set the TRXMD all the subordinate TCHs must be in LOCKED state. 14. In a GSMDCS or GSM850DCS concentric cell, the GSUP parameter of TRX object can be set at TRUE only if the carrier frequency of the TRX belongs to the same band of BCCH frequency. UNSUCCESSFUL_EDGE_ON_BCCH_AVAILABLE The attribute TRXMD (of BCCH TRX) can not be set at GSM if EBCCHTRX is set at TRUE. INCOMP_NESWLOAD_VS_MESSAGE The attribute TRXMD can not be set at EDGE if the SWVersion running on the superordinated BTSMobject belongs to BR6.0 release (see EXPSWV parameter description). The attribute TRXMD can not be set at EDGE if the BTSE is not a BTS+. UNSUCCESSFUL_GPRS_ENABLED The attribute GSUP can not be set at FALSE if EGPRS is set at TRUE and none of remaining TRXs in the cell has GSUP set at TRUE. UNSUCCESSFUL_HOPPING_SYSTEM_INCONSISTENT The attribute TRXMD can not be set at GSMor EDGE if the TRX belongs to a hopping law. A30808-X3247-L230-3-7619 1385 Commands Base Station Controller CML:BSC In case of EXT900, all the TRXs for which the GSUP is set at TRUE must belong to the same band of BCCH frequency. In case of F2ONLY, if the BCCH belongs to BB900 band, all the TRXs for which the GSUP is set at TRUE must belong to the BB900 band. 15. If only one 64 kbit/s LAPD channel is created in BSC and BTSE, the number of full rate and half rate TRXs to be congured is limited and might be lower than the maximum possible of 24 TRXs, in order not to increase the Call Failure Rate (the expression half(full) rate TRXs only means how many TRXs would be covered if the HR(FR) channels were on the same TRXs; the intention is to have a practical and not too detailed result). The maximum allowed number of congured full rate and half rate TRXs can be estimated according to the following rule: 2 * (number of half rate TRXs) + (number of full rate TRXs) <= 32. This rule is valid only if no radio measurements are activated within a BTSM. If two or more 64 kbit/s LAPD channels are created there is no limitation for the number of congured TRXs. 16. Special care has to be applied if the RADIOMR attribute is set at ON for several TRXs. For more details see Appendix B: Group 8. Example of Command Execution Set TRX:NAME=BTSM:0/BTS:0/TRX:0,TRXFREQ=BCCHFREQ,PWRRED=0, RADIOMR=ON,RADIOMG=2,MOEC=TRUE,TRXAREA=NONE,GSUP=FALSE, TRXMD=GSM; SHUTDOWN TRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX SHUTDOWN TRX Applicability: Phase 2. Visibility level 1. Command Description: This command allows the graceful transition of an object from the administrative state "Unlocked" to the administrative state "Locked" after the object has terminated its current activity. The BSS is able to force a mobile station to perform an intracell, intercell or inter-BSC HO by means of the O&MSHUTDOWN command. After the SHUTDOWN command is entered, the system tries to perform an intracell, intercell or inter-BSC HO per mobile station; in case of failure, a further attempt is performed every 30 seconds for the next 5 minutes period. If after the predefined period (5.5 minutes) the current activity is not terminated, the administrative state will be set at Locked. If one of the objects is still active or busy after the predefined period, ongoing calls will be dropped. SHUTDOWN TRX: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn; 1386 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Validity ranges of the object addresses btsmn, "btsn" and "trxn" can be found in Appendix A. System Responses: Application Guidelines: 1. If the operator has started too many shutdown commands, the system will display the SM TOO BUSY message. 2. Possible state transitions and timing: a) UNLOCKED -immediately-> SHUTTING DOWN ---------- immediately ----------> LOCKED b) UNLOCKED -immediately-> SHUTTING DOWN ---------- 5.5 minutes ----------> LOCKED c) UNLOCKED -immediately-> SHUTTING DOWN ---------- after object went to idle state ----------> LOCKED The state changes described above show all the possible transitions when the shut- down command was performed. The rst column of the table gives the situations which are affected by doing a shutdown of an object. Example of Command Execution Shutdown TRX:NAME=BTSM:0/BTS:0/TRX:0; SHUTDOWN TRX ACK: SHUTDOWN TRX NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SITUATIONS TRANSITIONS FORCED/NOT FORCED idle object a) busy object but not released after the SHUTDOWN command b) busy object but released after the SHUTDOWN command c) A30808-X3247-L230-3-7619 1387 Commands Base Station Controller CML:BSC UNLOCK TRX Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX UNLOCK TRX Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". Validity ranges of the object addresses btsmn, "btsn" and "trxn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock TRX:NAME=BTSM:0/BTS:0/TRX:0; UNLOCK TRX: NAME=BTSM:btsmn/BTS:btsn/TRX:trxn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1388 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TRXTD The TRXTD (Transceiver) object locates the transceivers connected to a certain BSC. CREATE TRXTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC BTSTD TRXTD CREATE TRXTD Applicability: Phase 2. Visibility level 2. Command Description: This command defines the global parameters of the TD-SCDMA Transceiver (TRXTD) . Validity ranges of the object addresses btsmtdn, "btstdn" and "trxtdn" can be found in Appendix A. System Responses: CREATE TRXTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn ,TRXTDFREQ= [,TXPMAREDTD=][,RADIOMR=] [,RADIOMG=] ,LPDLMTDN=; CREATE ACK: Successful CREATE NACK NACK CAUSES: UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED The relevant BTSTD object instance must be already created. UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED The instance of the TRXTD managed object must not be already equipped. UNSUCCESSFUL_VAR_OUT_OF_RANGE The maximum number of TRXTDs per BSS has been reached; no other TRXTDs can be equipped. UNSUCCESSFUL_FREQUENCY_NOT_BELONG_TO_CEL The carrier frequency (TRXTDFREQ) of the TRXTD must belong to the set of frequencies assigned to the supeordinate BTSTD. UNSUCCESSFUL_FREQ_BELONG_TO_ANOTHER_TRX The carrier frequency (TRXTDFREQ) of the TRXTD must not be already assigned to another TRXTDbelonging to the same BTSTD. A30808-X3247-L230-3-7619 1389 Commands Base Station Controller CML:BSC Application Guidelines: 1. If the transceiver carrier frequency corresponds to the frequency indicated by the BCCHFREQTD parameter (previously set at the creation of the BTSTD managed object), then it is assumed that the transceiver is the broadcast one. 2. After the creation of the object the ADMINISTRATIVE state of this object is set at LOCKED. An UNLOCK command is required to put this object in service. Example of Command Execution Create TRXTD:NAME=BTSMTD:0/BTSTD:0/TRXTD:0,TRXTDFREQ=CALLF01TD, TXPMAREDTD=30,RADIOMR=ON,RADIOMG=2,LPDLMTDN=0; UNSUCCESSFUL_MEMORY_CORRUPTED The maximumnumber of LPDLTD in BSC has been reached; no other LPDLTD can be equipped. UNSUCCESSFUL_NO_MORE_FREQ_AVAILABLE No more frequencies are available to create a new TRXTD. After TRXTD instance 0 is created, if the BTSTD is not prop- erly equipped, it is not possible to create a new TRXTD instance. 1390 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DELETE TRXTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD DELETE TRXTD Applicability: Phase 2. Visibility level 2. Command Description: This command deletes a previously created TRXTD. Validity ranges of the object addresses btsmtdn, "btstdn" and "trxtdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Delete TRXTD:NAME=BTSMTD:0/BTSTD:0/TRXTD:0; DELETE TRXTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_STATUS Before deleting a TRXTD, the relative object instance must be in LOCKED state. UNSUCCESSFUL_DEL_ALL_AIRTSTD_TRXTD_BEFORE Before deleting a TRXTD object instance it is necessary to delete all the airtstds belonging to the involved TRXTD. A30808-X3247-L230-3-7619 1391 Commands Base Station Controller CML:BSC GET TRXTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD GET TRXTD Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameters of a previously created TRXTD. Validity ranges of the object addresses btsmtdn, "btstdn" and "trxtdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get TRXTD:NAME=BTSMTD:0/BTSTD:0/TRXTD:0,REQATTL=TRXTDFREQ& TXPMAREDTD& RADIOMR&RADIOMG&LPDLMTDN&TRXFREQVTD&TEI; GET TRXTD BASICS GET TRXTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn [,REQATTL= TRXTDFREQ, TXPMAREDTD, RADIOMR, RADIOMG, LPDLMTDN, TRXFREQVTD, TEI]; GET ACK: TRXTDFREQ: trxtdFrequency TXPMAREDTD: txPwrMaxReductionTD BCCHTRXTD: bcchTransceiverTD RADIOMR: radioMeasRep RADIOMG: radioMeasGran LPDLMTDN:lapdmtdNumber TRXFREQVTD:carrierFrequencyValueTD TEI:tei GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. GET TRXTD BASICS: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn; 1392 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD GET TRXTD BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. Validity ranges of the object addresses btsmtdn, "btstdn" and "trxtdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get TRXTD BASICS:NAME=BTSMTD:0/BTSTD:0/TRXTD:0; GET ACK: TRXTDFREQ: trxtdFrequency TXPMAREDTD: txPwrMaxReductionTD BCCHTRXTD: bcchTransceiverTD RADIOMR: radioMeasRep RADIOMG: radioMeasGran LPDLMTDN:lapdmtdNumber TRXFREQVTD:carrierFrequencyValueTD TEI:tei GET NACK: NACK CAUSES: NOT_EQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1393 Commands Base Station Controller CML:BSC GET TRXTD STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD GET TRXTD STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the TRXTD object: Administrative State (AST) Operational State (OST) Usage State (UST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Procedural Status (PRS) Unknown Status (UNK). Validity ranges of the object addresses btsmtdn, "btstdn" and "trxtdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get TRXTD STAT:NAME=BTSMTD:0/BTSTD:0/TRXTD:0; GET TRXTD STAT: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn; GET TRXTD STAT ACK: GET TRTDX STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1394 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETINFO TRXTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD GETINFO TRXTD Applicability: Phase 2. Visibility level 2. Command Description: This command is used to retrieve the following information: 1. The report complete indication. 2. The states and statuses of the TRXTD: AST, OST, UST, AVS, PRS. 3. The TRXTD absolute number. 4. For each airtstd of the TRXTD , the states and statuses (AST, OST, UST, AVS), the direction, the current spreading factor, all the resource type and the list of connected abis timeslots. Validity ranges of the object addresses btsmtdn, "btstdn" and "trxtdn" can be found in Appendix A. System Responses: GETINFO TRXTD ACK: BSC_CONTROLLER -> LMT_LOCAL 11:41:14 22/03/1999 *** INFORMATION *** GET INFO REPORT TRXTD: NAME = TRXTD:0 REPORT COMPLETE: TRUE ADMINISTRATIVE STATE UNLOCKED OPERATIONAL STATE ENABLED USAGE STATE IDLE AVAILABILITY STATUS DEPENDENCY PROCEDURAL STATUS NONE TRXTD ABSOLUTE NR: 5 AIRTSTD 0 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE GETINFO TRXTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn; A30808-X3247-L230-3-7619 1395 Commands Base Station Controller CML:BSC USAGE STATE: IDLE DIRECTION: UPLINK CURRENT SF: DYNAMIC SPREADING CODE RESOURCE TYPE 0 P_RACK 1 P_FACH 2 P_SCCPCH 3 TRAFFIC-CIRCUIT-DATA 23 TRAFFIC-CIRCUIT-DATA CONNECTED ABIS: 12-15-0 AIRTSTD 6 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE USAGE STATE: IDLE DIRECTION: DOWNLINK CURRENT SF: N-16 SPREADING CODE RESOURCE TYPE 0 P_RACK 1 IDLE 2 P_SCCPCH 3 TRAFFIC-CIRCUIT-DATA 23 TRAFFIC-CIRCUIT-DATA CONNECTED ABIS: 12-14-0 12-14-1 12-14-2 12-14-3 END OF REPORT GETINFO TRXTD NACK: BSC_CONTROLLER -> LMT_LOCAL 16:24:45 22/09/1998 *** RESPONSE TO JOB 1*** Get Info Report Nack TRXTD: NAME = TRXTD:0 nackCause = <nack cause> NACK CAUSES: UNSUCCESSFUL_WRONG_ME_ID The object received in input is not handled by the subsystem. UNSUCCESSFUL_OBJECT_NOTEQUIPPED 1396 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Getinfo TRXTD:NAME=BTSMTD:0/BTSTD:0/TRXTD:0; GETRELATIONSHIP TRXTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD GETRELATIONSHIP TRXTD Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of the all HMOs (Hardware Managed Object) supporting the FMO functionality. For the TRXTD object the related HMOs are the following: EPWR, LICD, LICDS, PWRD, MPCC, PPXT, MEMT, NTWand all the BTSE HMOs that implement the TRXTD functionality for the BTSC. Validity ranges of the object addresses btsmtdn, "btstdn" and "trxtdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship TRXTD:NAME=BTSMTD:0/BTSTD:0/TRXTD:0; The object instance must be already equipped. T_REQUEST_ALREADY_IN_PROGRESS If another GetInfo on the input object is already running. T_RESOURCE_NOT_AVAILABLE If there are 10 GetInfo commands already in progress. GETRELATIONSHIP TRXTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtd n; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. A30808-X3247-L230-3-7619 1397 Commands Base Station Controller CML:BSC GETSUBO TRXTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD GETSUBO TRX Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. Validity ranges of the object addresses btsmtdn, "btstdn" and "trxtdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getsubo TRXTD:NAME=BTSMTD:0/BTSTD:0/TRXTD:0; LOCK TRXTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD LOCK TRXTD GETSUBO TRXTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn; GETSUBO TRXTD ACK: The output of the command can be composed by one or more pack with a maximumnumber of ten subordinated mnemonics; at the end there a message is displayed notifying the end of the subordinate list. GETSUBO TRXTD NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. LOCK TRXTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn; 1398 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". Validity ranges of the object addresses btsmtdn, "btstdn" and "trxtdn" can be found in Appendix A. System Responses: Application Guidelines: 1. If object TRXTD is locked, calls using the concerned objects are dropped. To avoid loss of calls by locking the TRXTD object a request for usage state of this objects should be done previously (e.g. GET state status). In case returned usage state is "active" or "busy" locking should not be done (otherwise calls are dropped). 2. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. 3. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock TRXTD:NAME=BTSMTD:0/BTSTD:0/TRXTD:0; SET TRXTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD SET TRXTD Applicability: Phase 2. Visibility level 2. LOCK TRXTD ACK: LOCK TRXTD NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SET TRXTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn [,TRXTDFREQ=] [,TXPMAREDTD=][,RADIOMR=] [,RADIOMG=]; A30808-X3247-L230-3-7619 1399 Commands Base Station Controller CML:BSC Command Description: This command modifies the global parameters of the TD-SCDMA Transceiver for the TRXTD dedicated to both traffic and BCCH function. Validity ranges of the object addresses btsmtdn, "btstdn" and "trxtdn" can be found in Appendix A. System Responses: Application Guidelines: None Example of Command Execution Set TRXTD:NAME=BTSMTD:0/BTSTD:0/TRXTD:0,TRXTDFREQ=CALLF01TD, TXPMAREDTD=30,RADIOMR=ON,RADIOMG=2; SHUTDOWN TRXTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD SHUTDOWN TRXTD Applicability: Phase 2. Visibility level 1. SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_FREQUENCY_NOT_BELONG_TO_CEL The carrier frequency (TRXTDFREQ) of the TRXTDmust belong to the set of frequencies assigned to the superordinate BTSTD. UNSUCCESSFUL_FREQ_BELONG_TO_ANOTHER_TRX The carrier frequency (TRXTDFREQ) of the TRXTD must not be already assigned to another TRXTD belonging to the same BTSTD. UNSUCCESSFUL_INVALID_STATUS If the TRXTD is not the broadcast one, then TRXTDFREQ can be set if the TRXTD object is LOCKED. If the TRXTD is the broadcast one, then the TRXTDFREQ attribute can be set if the BTSTD object is LOCKED. UNSUCCESSFUL_DEL_ALL_AIRTSTD_TRXTD_BEFORE If the TRXTD is the broadcast one, then the TRXTDFREQ attribute can be set if all subordinate AIRTSTD are not equipped. SHUTDOWN TRXTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn; 1400 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Command Description: This command allows the graceful transition of an object from the administrative state "Unlocked" to the administrative state "Locked" after the object has terminated its current activity. The BSS is able to force a mobile station to perform an intracell, intercell or inter-BSC HO by means of the O&MSHUTDOWN command. After the SHUTDOWN command is entered, the system tries to perform an intracell, intercell or inter-BSC HO per mobile station; in case of failure, a further attempt is performed every 30 seconds for the next 5 minutes period. If after the predefined period (5.5 minutes) the current activity is not terminated, the administrative state will be set at Locked. If one of the objects is still active or busy after the predefined period, ongoing calls will be dropped. Validity ranges of the object addresses btsmtdn, "btstdn" and "trxtdn" can be found in Appendix A. System Responses: Application Guidelines: 1. If the operator has started too many shutdown commands, the system will display the SM TOO BUSY message. 2. Possible state transitions and timing: a) UNLOCKED -immediately-> SHUTTING DOWN ---------- immediately ----------> LOCKED b) UNLOCKED -immediately-> SHUTTING DOWN ---------- 5.5 minutes ----------> LOCKED c) UNLOCKED -immediately-> SHUTTING DOWN ---------- after object went to idle state ----------> LOCKED The state changes described above show all the possible transitions when the shut- down command was performed. The rst column of the table gives the situations which are affected by doing a shutdown of an object. SHUTDOWN TRXTD ACK: SHUTDOWN TRXTD NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SITUATIONS TRANSITIONS FORCED/NOT FORCED idle object a) busy object but not released after the SHUTDOWN command b) busy object but released after the SHUTDOWN command c) A30808-X3247-L230-3-7619 1401 Commands Base Station Controller CML:BSC Example of Command Execution Shutdown TRXTD:NAME=BTSMTD:0/BTSTD:0/TRXTD:0; 1402 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller UNLOCK TRXTD Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BTSMTD BTSTD TRXTD UNLOCK TRXTD Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". Validity ranges of the object addresses btsmtdn, "btstdn" and "trxtdn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock TRXTD:NAME=BTSMTD:0/BTSTD:0/TRXTD:0; UNLOCK TRXTD: NAME=BTSMTD:btsmtdn/BTSTD:btstdn/TRXTD:trxtdn; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1403 Commands Base Station Controller CML:BSC TSLA The TSLA object represents one of the time slots on the A interface. GET TSLA Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMA TSLA GET TSLA Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameters of the TSLA object. Validity ranges of the object addresses "pcman" and "tsln" can be found in Appendix A. System Responses: Application Guidelines: A command to GET all the TSLA belonging to a PCMA is provided. The command is GET TSLA-pcman-ALL and return for each TSLA spontaneos message with the same format of the GET ACK systemresponse excluded the last time slot for which is returned the GET ACK message. The number of message returned dependes on the PCM type selected. For PCM30 is returned a message for each time slot from 1 to 31 while for PCM24 is returned a message for each time slot from 1 to 24. Example of Command Execution Get TSLA:NAME=PCMA:0/TSLA:1,REQATTL=VOLUL&VOLDL&POOLTYP; GET TSLA: NAME=PCMA:pcman/TSLA:tsln [,REQATTL=VOLUL, VOLDL, POOLTYP]; GET ACK: NAME:name VOLUL: volumeUpLink VOLDL:volumeDownLink POOLTYP:PoolType GET NACK: NOT_EQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_TIME_SLOT The range of address tsln is not compatible with the PCM line type attribute (parameter PCMTYPE of BSC object). 1404 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET TSLA BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMA TSLA GET TSLA BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve all the parameter related to the TSLA object. Validity ranges of the object addresses "pcman" and "tsln" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get TSLA BASICS:NAME=PCMA:0/TSLA:1; GET TSLA STAT Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT PCMA TSLA GET TSLA STAT Applicability: Phase 2. Visibility level 0. GET TSLA BASICS: NAME=PCMA:pcman/TSLA:tsln; GET TSLA BASICS ACK: NAME:name VOLUL: volumeUpLink VOLDL:volumeDownLink POOLTYP:poolType GET TSLA BASICS NACK: NOT_EQUIPPED The object instance must be already equipped. GET TSLA STAT: NAME=PCMA:pcman/TSLA:tsln; A30808-X3247-L230-3-7619 1405 Commands Base Station Controller CML:BSC Command Description: This command is used to retrieve the following State/Status attributes related to the TSLA object: Administrative State (AST) Operational State (OST) Usage State (UST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). Validity ranges of the object addresses "pcman" and "tsln" can be found in Appendix A. System Responses: Application Guidelines: Only sets with raised bits are shown. Example of Command Execution Get TSLA STAT:NAME=PCMA:0/TSLA:1; GETRELATIONSHIP TSLA Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT PCMA TSLA GETRELATIONSHIP TSLA Command Description: This command is used to retrieve the functional relationship information for the selected FMO (Functional Managed Object); the relationship information consist of the all HMOs (Hardware Managed Object) supporting the FMO functionality. This information is included in the RELATED_EQUIPMENT_OBJECTS attribute (ATTID parameter). For the TSLA object the related HMOs are the following: LICD/LICDS, EPWR, BSMS, TPWR, PPLD, TRAC, PWRD, MPCC, TDPC, MEMT and NTW. Validity ranges of the object addresses "pcman" and "tsln" can be found in Appendix A. GET TSLA STAT ACK: GET TSLA STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. GETRELATIONSHIP TSLA: NAME=PCMA:pcman/TSLA:tsln, ATTID=; 1406 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller System Responses: Application Guidelines: None. Example of Command Execution Getrelationship TSLA:NAME=PCMA:0/TSLA:1, ATTID=RELATED_EQUIPMENT_OBJECTS; GETSUBO TSLA Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT PCMA TSLA GETSUBO TSLA Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the list of direct subordinate objects of a specified object. Validity ranges of the object addresses "pcman" and "tsln" can be found in Appendix A. System Responses: GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected FMOthe list of related HMOs is displayed (FMO to HMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. GETSUBO TSLA: NAME=PCMA:pcman/TSLA:tsln; GETSUBO TSLA ACK: The output of the command can be composed by one or more pack with a maximum number of ten subordinated mnemonics; at the end there a message is displayed noti- fying the end of the subordinate list. GETSUBO TSLA NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1407 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Getsubo TSLA:NAME=PCMA:0/TSLA:1; LOCK TSLA Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT PCMA TSLA LOCK TSLA Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Locked". Validity ranges of the object addresses "pcman" and "tsln" can be found in Appendix A. System Responses: Application Guidelines: 1. If object TRX or CHAN is locked, calls using the concerned objects are dropped. To avoid loss of calls by locking objects TRX or CHAN a request for usage state of this objects should be done previously (e.g. GET state status). In case returned usage state is "active" or "busy" locking should not be done (otherwise calls are dropped). 2. The LOCK command is only force type and it is always executed no matter what the conguration of the object is. This is valid for all objects, but MPCC, IXLT, PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected). 3. The administrative state Locked will survive at the Full Init (and consequently to the load database) for a maximum of 200 objects (on a FIFO basis). Example of Command Execution Lock TSLA:NAME=PCMA:0/TSLA:1; LOCK TSLA NAME=PCMA:pcman/TSLA:tsln; LOCK TSLA ACK: LOCK TSLA NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1408 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SET TSLA Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT PCMA TSLA SET TSLA Applicability: Phase 2. Visibility level 2. Command Description: This command sets the desired values of the uplink and downlink volumes on a specified couple pcma_line-time_slot_number (previously created). Validity ranges of the object addresses "pcman" and "tsln" can be found in Appendix A. System Responses: Application Guidelines: None. SET TSLA: NAME=PCMA:pcman/TSLA:tsln [,VOLUL=] [,VOLDL=] [,POOLTYP=]; SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_INVALID_TIME_SLOT Time slot 0 is not allowed. The range of address tsln is not compatible with the PCMline type attribute (parameter PCMTYPE of BSC object). UNSUCCESSFUL_INVALID_ATTRIBUTES In order to set the POOLTYP attribute the pooling must be enabled (attribute EPOOL of BSC object). The attribute POOLTYP cannot assume the value POOL_23 or POOL_46 if the relative TRAU is not AMR and back. If TRAUis not S3 (fourth digit of EXPSWV attribute is not 03), the attribute DEFPOOLTYP cannot assume the values from POOL_24 to POOL_35 and the values POOL_47 and POOL_48 UNSUCCESSFUL_OBJECT_NOTEQUIPPED The superordinate PCMA object instance must be already equipped. In order to set the POOLTYP attribute the related TRAUobject instance must be in LOCKED state. NOT_ENOUGH_SUBSLOTS_IN_PCMS In order to set the POOLTYP attribute there must be enough PCMS subslots still unmapped to fulll the request of the new TSLA pool type. A30808-X3247-L230-3-7619 1409 Commands Base Station Controller CML:BSC Example of Command Execution Set TSLA:NAME=PCMA:0/TSLA:1,THROUGH=4,VOLUL=2,VOLDL=2, POOLTYP=POOL_1; SHUTDOWN TSLA Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT PCMA TSLA SHUTDOWN TSLA Applicability: Phase 2. Visibility level 1. Command Description: This command allows the graceful transition of an object from the administrative state "Unlocked" to the administrative state "Locked" after the object has terminated its current activity. The systemattempts to performthe command every 10 seconds for the next 6 minutes. If after the predefined period (5.5 minutes) the current activity is not terminated, the administrative state will be set at Locked. If one of the objects is still active or busy after the predefined period, ongoing calls will be dropped. Validity ranges of the object addresses "pcman" and "tsln" can be found in Appendix A. System Responses: Application Guidelines: 1. If the operator has started too many shutdown commands, the system will display the SM TOO BUSY message. 2. Possible state transitions and timing: a) UNLOCKED -immediately-> SHUTTING DOWN ---------- immediately ----------> LOCKED b) UNLOCKED -immediately-> SHUTTING DOWN ---------- 6 minutes and 10 seconds ----------> LOCKED c) UNLOCKED -immediately-> SHUTTING DOWN ---------- after object went to idle state ----------> LOCKED The state changes described above show all the possible transitions when the shut- down command was performed. SHUTDOWN TSLA: NAME=PCMA:pcman/TSLA:tsln; SHUTDOWN TSLA ACK: SHUTDOWN TSLA NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state LOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. 1410 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller The rst column of the table gives the situations which are affected by doing a shut- down of an object. Example of Command Execution Shutdown TSLA:NAME=PCMA:0/TSLA:1; UNLOCK TSLA Command Tree: MANAGED-ELEMENT BSS-EQUIPMENT PCMA TSLA UNLOCK TSLA Applicability: Phase 2. Visibility level 1. Command Description: This command allows to set an object to the administrative state "Unlocked". Validity ranges of the object addresses "pcman" and "tsln" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Unlock TSLA:NAME=PCMA:0/TSLA:1; SITUATIONS TRANSITIONS FORCED/NOT FORCED idle object a) busy object but not released after the SHUTDOWN command b) busy object but released after the SHUTDOWN command c) UNLOCK TSLA: NAME=PCMA:pcman/TSLA:tsln; UNLOCK ACK: UNLOCK NACK: NACK CAUSES: ALREADY_IN_TARGET_STATE The object instance is in the administrative state UNLOCKED. UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. A30808-X3247-L230-3-7619 1411 Commands Base Station Controller CML:BSC TSLB The TSLB object is automatically created at the PCMB creation and provides the functionality of the 64 kbit/s time slots on the Abis interface. It has been defined for addressing reasons only and has neither attributes nor commands. GET TSLB Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL PCMB TSLB GET TSLB Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameters of the TSLB object. Validity ranges of the object addresses "tslbn" and "subtslbn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Get TSLB:NAME=PCMB:0/TSLB:1; GET TSLB: NAME=PCMB:0/TSLB:1; GET ACK: NAME:name GET NACK: 1412 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller A30808-X3247-L230-3-7619 1413 Commands Base Station Controller CML:BSC X25A The X25A object represents the physical link - pcma line number, timeslot number - on the PCMA interface used to communicate with the external network elements. CREATE X25A Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL X25A CREATE X25A Applicability: Phase 2. Visibility level 2. Command Description: This command adds the object X25A representing the physical link of A interface to communicate with the external network elements. The validity range of the object address "x25an" can be found in Appendix A. System Responses: CREATE X25A: NAME=X25A:x25an ,ACHAN= [,T1=] [,T4=] [,RETRY=] [,L2WIN=] [,LCN2WC=] [,L3WIN=] [,T20=] [,T21=] [,T22=] [,T23=] [,T26=] [,T28=] [,R20=] [,R22=] [,R23=] [,L3PS=] [,TRACE=] [,N2WC=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. The objects X25A and X25D are mutually exclusive, i.e. if an X25A is already EQUIPPED, an X25D cannot be EQUIPPED and vice versa. SUPERORDINATE_NOTEQUIPPED The PCMA used for the link must be already equipped. UNSUCCESSFUL_INVALID_TIME_SLOT Make reference to APPLICATION GUIDELINE n. 1. UNSUCCESSFUL_TIME_SLOT_ALREADY_ALLOCATED The timeslot of the PCMS to support the SS7L must be free. The selected TSLA is already carrying a NUC. UNSUCCESSFUL_INVALID_STATUS Make reference to APPLICATION GUIDELINES n. 1 and n. 2. 1414 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The range of the eld tslNumber of the attribute ACHAN is different depending on the attribute PCMTYPE of the BSC object. If the attribute PCMTYPE is equal to PCM30, the range is 1..31, otherwise (PCM24) the range is 1..24. 2. In order to create a X25A the related TRAU object must be locked. Example of Command Execution Create X25A:NAME=X25A:0,ACHAN=0-27,T1=27,T4=200,RETRY=8, L2WIN=1,LCN2WC=1,L3WIN=1,T20=1000,T21=1000,T22=1800,T23=3000,T26=400, T28=600,R20=55,R22=4,R23=10,L3PS=Packet_512,TRACE="0101010101"; DELETE X25A Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL X25A DELETE X25A Applicability: Phase 2. Visibility level 2. Command Description: This command deletes the X25A object. The validity range of the object address "x25an" can be found in Appendix A. System Responses: UNSUCCESSFUL_COPY_ZERO_NOTEQUIPPED The creation of copy #1 is subordinated to the presence of copy #0. IXLT_NOT_YET_LOCKED The creation of copy #1 of X25A is possible only if the IXLT -1 is LOCKED. INVALID_COMMAND No mixed configurations are possible, that is, if the IPLI object is already equipped, a CREATE X25A command is refused. DELETE X25A: NAME=X25A:x25an; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SUBORDINATE_EQUIPPED A30808-X3247-L230-3-7619 1415 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Delete X25A:NAME=X25A:0; GET X25A Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL X25A GET X25A Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameters of OSI level 1, level 2 and level 3 of the X25A object. The validity range of the object address "x25an" can be found in Appendix A. System Responses: The OMAL and CBCL object instances using the link asso- ciated to the X25 object instance must be previously deleted. UNSUCCESSFUL_INVALID_STATUS Before deleting an X25A, the relative object instance must be in LOCKED state. UNSUCCESSFUL_COPY_ONE_EQUIPPED The deletion of the instance #0 is possible only if the copy #1 is not present. GET X25A: NAME=X25A:x25an [,REQATTL= ACHAN, L2PV, T1, T4, RETRY, L2WIN, PVC, NIOC, NOOC, LCNIOC, LCN2WC, LCNOOC, L3WIN, T20, T21, T22, T23, T26, T28, R20, R22, R23, L3PV, FCTRL, L3PS, TRACE, N2WC]; GET ACK: NAME: name ACHAN: pcmaNumber pcmaNumber tslNumber: timeslotNumber L2PV: layer2ProtocolVariant T1: timerT1 T4: timerT4 1416 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get X25A:NAME=X25A:0,REQATTL=ACHAN&L2PV&T1&T4&RETRY&L2WIN& PVC&NIOC&NOOC&LCNIOC&LCN2WC&LCNOOC&L3WIN&T20&T21& T22&T23&T26&T28&R20&R22&R23&L3PV&FCTRL&L3PS&TRACE&N2WC; GET X25A BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL X25A GET X25A BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "x25an" can be found in Appendix A. RETRY: retryNumber L2WIN: layer2WindowSize PVC: pvc NIOC: numberOfIncomingOnly NOOC: numberOfOutgoingOnly LCNIOC: lcnOf1stIncomingOnly LCN2WC: lcnOf1st2WayChannels LCNOOC: lcnOf1stOutgoingOnly L3WIN: networkLayerWindowSize T20: restartRequestTimeout T21: callRequestTimeout T22: resetRequestTimeout T23: clearRequestTimeout T26: interruptRequestTimeout T28: registrationRequestTimeout R20: restartRequestRetryCount R22: resetRequestRetryCount R23: clearRequestRetryCount L3PV: networkLayerProtocolVariant FCTRL: flowControlNegotiation L3PS: networkLayerPacketsize TRACE: debuggingCodedString N2WC: numberOf2WayChannels GET X25A BASICS: NAME=X25A:x25an; A30808-X3247-L230-3-7619 1417 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: None. Example of Command Execution Get X25A BASICS:NAME=X25A:0; GET X25A STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL X25A GET X25A STAT GET X25A BASICS ACK: NAME: name ACHAN: pcmaNumber pcmaNumber tslNumber: timeslotNumber L2PV: layer2ProtocolVariant T1: timerT1 T4: timerT4 RETRY: retryNumber L2WIN: layer2WindowSize PVC: pvc NIOC: numberOfIncomingOnly N2WC: numberOf2WayChannels NOOC: numberOfOutgoingOnly LCNIOC: lcnOf1stIncomingOnly LCN2WC: lcnOf1st2WayChannels LCNOOC: lcnOf1stOutgoingOnly L3WIN: networkLayerWindowSize T20: restartRequestTimeout T21: callRequestTimeout T22: resetRequestTimeout T23: clearRequestTimeout T26: interruptRequestTimeout T28: registrationRequestTimeout R20: restartRequestRetryCount R22: resetRequestRetryCount R23: clearRequestRetryCount L3PV: networkLayerProtocolVariant FCTRL: flowControlNegotiation L3PS: networkLayerPacketsize TRACE: debuggingCodedString GET X25A STAT: NAME=X25A:x25an; 1418 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the X25A object: Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "x25an" can be found in Appendix A. System Responses: Application Guidelines: 1. TSYNC should be equal to TTRAU parameter. 2. Only sets with raised bits are shown. 3. Explanation of the meaning of OMAL ,IXLT, CBCL, X25A and X25D status: The handling of the status attributes may be summarized as follows: GET X25A STAT ACK: GET X25A STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. Value X25A standby PROVIDINGSERVICE not used HOT STANDBY not used COLD STANDBY not used NULL_STATUS not used availability FAILED layer 2 is down DEGRADED not used OFF_DUTY not used DEPENDENCY if PCMA is LOCKED or DISABLED procedural INITIALIZING not used Tab. 2.7 Status Attributes Handling of GET X25A STAT X25A ENABLED layer 2 up Tab. 2.8 Enable/Disable X25A A30808-X3247-L230-3-7619 1419 Commands Base Station Controller CML:BSC Example of Command Execution Get X25A STAT:NAME=X25A:0; GETINFO X25A Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL X25A GETINFO X25A Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the whole set of information regarding the X25A object; the given information is organized as follows: For each X25 copies: 1. X25 type: if the X25 is connected via Asub (X25A) or in dedicated way (X25D); 2. X25 Number: its the copy of X25; 3. IXLT Number: its the copy of IXLT that support the X25 link; 4. X25 Operational State 5. X25 Availability Status; 6. PPXX Number: its the number of PPLD/PPXL card that support the LPDLS; 7. PCMS Number: its the number of PCMS where the TRAU is connected to; 8. LICD Number: its the number of LICD card where the PCMS is connected to 9. LICD circuit: its the number of LICD circuit where the PCMS is connected to; 10. PCMA Number: its the PCMA where the X25A is connected; 11. TRAU Number : its the number of TRAU where the PCMA is connected to; 12. TRAU circuit: its the number of TRAU circtuit where the PCMA is connected to. For each OMAL copies: 1. OMAL Number: its the copy of OMAL; 2. IXLT Number: its the copy of IXLT that support the OMAL link; 3. OMAL Operational State; 4. OMAL Availability Status; 5. OMAL Standby Status; 6. Service Type; 7. Ftam Connection number. For each CBCL copies: 1. CBCL Number: its the copy of CBCL; 2. IXLT Number: its the copy of IXLT that support the CBCL link; 3. CBCL Administrative State; DISABLED layer 2 down Tab. 2.8 Enable/Disable X25A GETINFO X25A: NAME=X25A:x25an; 1420 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 4. CBCL Operational State; 5. CBCL Availability Status; 6. CBCL Standby Status. The validity range of the object address "x25an" can be found in Appendix A. System Responses: X25A 0: (X25 TYPE and NUMBER) IXLT NUMBER: 0 OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE PPXX: 0 PCMS: 0 LICD: 9 - 5 (LICD NR - LICD CIRC) PCMA: 0 TRAU-CIRCUIT: 0 - 1 (TRAU NR - PCMT NR) X25A 1: IXLT NUMBER: 1 OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE PPLD: 0 PCMS: 0 LICD: 9 - 5 (LICD NR - LICD CIRC) PCMA: 0 TRAU-CIRCUIT: 0 - 1 (TRAU NR - PCMT NR) OMAL 0: IXLT NUMBER: 1 OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE STANDBY STATUS: NONE SERVICE TYPE: CMIP OMAL 1: IXLT NUMBER: 0 OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE STANDBY STATUS: NONE SERVICE TYPE: FTAM FTAM CONNECTION: 1 A30808-X3247-L230-3-7619 1421 Commands Base Station Controller CML:BSC CBCL 0: IXLT NUMBER: 0 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE STANDBY STATUS: NONE CBCL 1: IXLT NUMBER: 0 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE STANDBY STATUS: NONE END OF REPORT Example of Command Execution Getinfo X25A:NAME=X25A:0; 1422 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETRELATIONSHIP X25A Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL X25A GETRELATIONSHIP X25A Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected HMO (Hardware Managed Object); the relationship information consist of all the FMOs (Functional Managed Object) using the HMO service. This information is included in the RELATED_FUNCTIONAL_OBJECTS attribute (ATTID parameter) and the attribute value depends on the working state of the target HMO. For the X25A object the CBCL and OMAL are the related FMOs. The validity range of the object address "x25an" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship X25A:NAME=X25A:0,ATTID=RELATED_FUNCTIONAL_OBJECTS; GETRELATIONSHIP X25A: NAME=X25A:x25an, ATTID=; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected HMO the list of related FMOs is displayed (HMO to FMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. A30808-X3247-L230-3-7619 1423 Commands Base Station Controller CML:BSC SET X25A Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL X25A SET X25A Applicability: Phase 2. Visibility level 2. Command Description: This command sets the parameters for the OSI level 2 and level 3 of X25A. The validity range of the object address "x25an" can be found in Appendix A. System Responses: Application Guidelines: 1. The value assigned to the timer t4 must be greater than the value of timer t1 or could be equal to 0.The value 0 assigned to the timer indicates that the timer is not managed. 2. The following rules must be respected: SET X25A: NAME=X25A:x25an [,T1=] [,T4=] [,RETRY=] [,L2WIN=] [,LCN2WC=] [,L3WIN=] [,T20=] [,T21=] [,T22=] [,T23=] [,T26=] [,T28=] [,R20=] [,R22=] [,R23=] [,L3PS=] [,TRACE=] [,N2WC=]; SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES Make reference to APPLICATION GUIDELINES n. 1 and n. 2. [(LCNIOC)...(LCNIOC+NIOC-1)] not intersected to (only for NIOC!=0) [(LCN2WC)...(LCN2WC+N2WC-1)] not intersected to (only for N2WC!=0) [(LCNOOC)...(LCNOOC+NOOC-1)] not intersected to (only for NOOC!=0) [(PVC)] E.g LCNIOC=1, NIOC=3 LCN2WC=4, N2WC=6 LCNOOC=10,NOOC=7 PVC=17 1424 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Set X25A:NAME=X25A:X25A:0,T1=27,T4=200,RETRY=8,L2WIN=1,LCN2WC=1, L3WIN=1,T20=1000,T21=1000,T22=1800,T23=3000,T26=400,T28=600,R20=255, R22=4,R23=10,L3PS=Packet_512, TRACE=0101010101; A30808-X3247-L230-3-7619 1425 Commands Base Station Controller CML:BSC X25D X25D represents the physical link of a dedicated line used for communication with the external network elements. CREATE X25D Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL X25D CREATE X25D Applicability: Phase 2. Visibility level 2. Command Description: This command adds the object X25D representing the physical link of a dedicated line used to communicate with the external network elements. The validity range of the object address "x25dn" can be found in Appendix A. System Responses: CREATE X25D: NAME=X25D:x25dn [,CLOCK=] [,BAUDRATE=] [,DTEDCE=] [,T1=] [,T4=] [,RETRY=] [,L2WIN=] [,LCN2WC=] [,L3WIN=] [,T20=] [,T21=] [,T22=] [,T23=] [,T26=] [,T28=] [,R20=] [,R22=] [,R23=] [,L3PS=] [,TRACE=] [,N2WC=]; CREATE ACK: Successful CREATE NACK: NACK CAUSES: OBJECT_ALREADY_EQUIPPED The instance of the object must not be already created in order to perform the command. The objects X25A and X25D are mutually exclusive, i.e. if an X25A is already EQUIPPED, an X25D cannot be EQUIPPED and vice versa. UNSUCCESSFUL_COPY_ZERO_NOTEQUIPPED The creation of copy #1 is subordinated to the presence of copy #0. IXLT_NOT_YET_LOCKED The creation of copy #1 of X25D is possible only if the IXLT-1 is LOCKED. INVALID_COMMAND No mixed configurations are possible, that is, if the IPLI object is already equipped, a CREATE X25D command is refused. 1426 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: 1. The CLOCK parameter must be set to EXTERNAL: in this case an external clock is used for RC-BSC conversation. If the CLOCK parameter is set at INTERNAL, an internal clock generated from IXLT is used. The usage of the internal clock leads to a Network switch every 30 seconds. 2. In case of RC-BSC connection by means of routers it is recommended to set T1, T4 and RETRY parameters at default values, in order to have a correct behaviour. Example of Command Execution Create X25D:NAME=X25D:0,CLOCK=EXTERNAL,BAUDRATE=Baud_64000, DTEDCE=DCE,T1=27,T4=200,RETRY=8,L2WIN=1,LCN2WC=1,L3WIN=1,T20=1000, T21=1000,T22=1800,T23=3000,T26=400,T28=600,R20=255,R22=4,R23=10, L3PS=Packet_512,TRACE=0101010101; DELETE X25D Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL X25D DELETE X25D Applicability: Phase 2. Visibility level 2. Command Description: This command deletes the X25D object. The validity range of the object address "x25dn" can be found in Appendix A. System Responses: Application Guidelines: None. DELETE X25D: NAME=X25D:x25dn; DELETE ACK: Successful DELETE NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. SUBORDINATE_EQUIPPED The OMAL and CBCL object instances using the link asso- ciated to the X25 object instance must be previously deleted. UNSUCCESSFUL_COPY_ONE_EQUIPPED The deletion of the instance #0 is possible only if the copy #1 is not present. A30808-X3247-L230-3-7619 1427 Commands Base Station Controller CML:BSC Example of Command Execution Delete X25D:NAME=X25D:0; 1428 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GET X25D Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC X25D GET X25D Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the parameters of OSI level 1, level 2 and level 3 of the X25D object. The validity range of the object address "x25dn" can be found in Appendix A. System Responses: GET X25D: NAME=X25D:x25dn [,REQATTL=CLOCK, BAUDRATE, DTEDCE,L2PV, T1, T4, RETRY, L2WIN, PVC, NIOC, NOOC, LCNIOC, LCN2WC, LCNOOC, L3WIN, T20, T21, T22, T23, T26, T28, R20, R22, R23, L3PV, FCTRL, L3PS, TRACE, N2WC]; GET ACK: NAME: name CLOCK: clock BAUDRATE: baudrate DTEDCE: dteDce L2PV: layer2ProtocolVariant T1: timerT1 T4: timerT4 RETRY: retryNumber L2WIN: layer2WindowSize PVC: pvc NIOC: numberOfIncomingOnly NOOC: numberOfOutgoingOnly LCNIOC: lcnOf1stIncomingOnly LCN2WC: lcnOf1st2WayChannels LCNOOC: lcnOf1stOutgoingOnly L3WIN: networkLayerWindowSize T20: restartRequestTimeout T21: callRequestTimeout T22: resetRequestTimeout T23: clearRequestTimeout T26: interruptRequestTimeout T28: registrationRequestTimeout R20: restartRequestRetryCount R22: resetRequestRetryCount A30808-X3247-L230-3-7619 1429 Commands Base Station Controller CML:BSC Application Guidelines: None. Example of Command Execution Get X25D:NAME=X25D:0,REQATTL=CLOCK&BAUDRATE&DTEDCE&L2PV& T1&T4&RETRY&L2WIN&PVC&NIOC&NOOC&LCNIOC&LCN2WC& LCNOOC&L3WIN&T20&T21&T22&T23&T26&T28&R20&R22&R23&L3PV&FCTRL& L3PS&TRACE&N2WC; GET X25D BASICS Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC X25D GET X25D BASICS Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the values of all the parameters of the BASICS group. The validity range of the object address "x25dn" can be found in Appendix A. System Responses: R23: clearRequestRetryCount L3PV: networkLayerProtocolVariant FCTRL: flowControlNegotiation L3PS: networkLayerPacketsize TRACE: debuggingCodedString N2WC: numberOf2WayChannels GET X25D BASICS: NAME=X25D:x25dn; GET X25D BASICS ACK: NAME: name CLOCK: clock BAUDRATE: baudrate DTEDCE: dteDce L2PV: layer2ProtocolVariant T1: timerT1 T4: timerT4 RETRY: retryNumber L2WIN: layer2WindowSize PVC: pvc NIOC: numberOfIncomingOnly N2WC: numberOf2WayChannels NOOC: numberOfOutgoingOnly 1430 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Application Guidelines: None. Example of Command Execution Get X25D BASICS:NAME=X25D:0; GET X25D STAT Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL X25D GET X25D STAT Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the following State/Status attributes related to the X25D object: Operational State (OST) Alarm Status (ALS) Availability Status (AVS) Control Status (CTS) Unknown Status (UNK). The validity range of the object address "x25dn" can be found in Appendix A. LCNIOC: lcnOf1stIncomingOnly LCN2WC: lcnOf1st2WayChannels LCNOOC: lcnOf1stOutgoingOnly L3WIN: networkLayerWindowSize T20: restartRequestTimeout T21: callRequestTimeout T22: resetRequestTimeout T23: clearRequestTimeout T26: interruptRequestTimeout T28: registrationRequestTimeout R20: restartRequestRetryCount R22: resetRequestRetryCount R23: clearRequestRetryCount L3PV: networkLayerProtocolVariant FCTRL: flowControlNegotiation L3PS: networkLayerPacketsize TRACE: debuggingCodedString GET X25D STAT: NAME=X25D:x25dn; A30808-X3247-L230-3-7619 1431 Commands Base Station Controller CML:BSC System Responses: Application Guidelines: 1. TSYNC should be equal to TTRAU parameter. 2. Only sets with raised bits are shown. 3. Explanation of the meaning of OMAL ,IXLT, CBCL, X25A and X25D status: The handling of the status attributes may be summarized as follows: Example of Command Execution Get X25D STAT:NAME=X25D:0; GETINFO X25D Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL X25D GETINFO X25D GET X25D STAT ACK: GET X25D STAT NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED Value X25D standby PROVIDINGSERVICE not used HOT STANDBY not used COLD STANDBY not used NULL_STATUS not used availability FAILED layer 2 is down DEGRADED not used OFF_DUTY not used DEPENDENCY not used procedural INITIALIZING not used Tab. 2.9 Status Attributes Handling of GET X25D STAT X25D ENABLED layer 2 up DISABLED layer 2 down Tab. 2.10 Enable/Disable X25D GETINFO X25D: NAME=X25D:x25dn; 1432 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Applicability: Phase 2. Visibility level 0. Command Description: This command is used to retrieve the whole set of information regarding the X25D object; the given information is organized as follows: For each X25 copies: 1. X25 type: if the X25 is connected via Asub (X25A) or in dedicated way (X25D); 2. X25 Number: its the copy of X25; 3. IXLT Number: its the copy of IXLT that support the X25 link; 4. X25 Operational State 5. X25 Availability Status. For each OMAL copies: 1. OMAL Number: its the copy of OMAL; 2. IXLT Number: its the copy of IXLT that support the OMAL link; 3. OMAL Operational State; 4. OMAL Availability Status; 5. OMAL Standby Status; 6. Service Type; 7. Ftam Connection number. For each CBCL copies: 1. CBCL Number: its the copy of CBCL; 2. IXLT Number: its the copy of IXLT that support the CBCL link; 3. CBCL Administrative State; 4. CBCL Operational State; 5. CBCL Availability Status; 6. CBCL Standby Status. The validity range of the object address "x25dn" can be found in Appendix A. System Responses: X25D 0: (X25 TYPE and NUMBER) IXLT NUMBER: 0 OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE PPXX: 0 PCMS: 0 LICD: 9 - 5 (LICD NR - LICD CIRC) PCMA: 0 TRAU-CIRCUIT: 0 - 1 (TRAU NR - PCMT NR) X25D 1: IXLT NUMBER: 1 OPERATIONAL STATE: ENABLED A30808-X3247-L230-3-7619 1433 Commands Base Station Controller CML:BSC AVAILABILITY STATUS: NONE OMAL 0: IXLT NUMBER: 1 OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE STANDBY STATUS: NONE SERVICE TYPE: CMIP OMAL 1: IXLT NUMBER: 0 OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE STANDBY STATUS: NONE SERVICE TYPE: FTAM FTAM CONNECTION: 1 CBCL 0: IXLT NUMBER: 0 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE STANDBY STATUS: NONE CBCL 1: IXLT NUMBER: 0 ADMINISTRATIVE STATE: UNLOCKED OPERATIONAL STATE: ENABLED AVAILABILITY STATUS: NONE STANDBY STATUS: NONE END OF REPORT Example of Command Execution Getinfo X25D:NAME=X25D:0; 1434 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETRELATIONSHIP X25D Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL X25D GETRELATIONSHIP X25D Applicability: Phase 2. Visibility level 1. Command Description: This command is used to retrieve the functional relationship information for the selected HMO (Hardware Managed Object); the relationship information consist of the all FMOs (Functional Managed Object) using the HMO service. This information is included in the RELATED_FUNCTIONAL_OBJECTS attribute (ATTID parameter) and the attribute value depends on the working state of the target HMO. For the X25D object the CBCL and OMAL are the related FMOs. The validity range of the object address "x25dn" can be found in Appendix A. System Responses: Application Guidelines: None. Example of Command Execution Getrelationship X25D:NAME=X25D:0,ATTID=RELATED_FUNCTIONAL_OBJECTS; GETRELATIONSHIP X25D: NAME=X25D:x25dn, ATTID=; GETRELATIONSHIP ACK: The functional relationship information is provided: for the selected HMO the list of related FMOs is displayed (HMO to FMO relationship). GETRELATIONSHIP NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES The managed object does not provide any relationship attribute. A30808-X3247-L230-3-7619 1435 Commands Base Station Controller CML:BSC SET X25D Command Tree: MANAGED-ELEMENT BSS-FUNCTIONAL BSC X25D SET X25D Applicability: Phase 2. Visibility level 2. Command Description: This command sets the parameters for the OSI level 2 and level 3 of X25D. The validity range of the object address "x25dn" can be found in Appendix A. System Responses: Application Guidelines: 1. The value assigned to the timer t4 must be greater than the value of timer t1 or could be equal to 0. The value 0 of timer t4 indicates that the timer is not managed. 2. The following rules must be respected: SET X25D: NAME=X25D:x25n [,T1=] [,T4=] [,RETRY=] [,L2WIN=] [,LCN2WC=] [,L3WIN=] [,T20=] [,T21=] [,T22=] [,T23=] [,T26=] [,T28=] [,R20=] [,R22=] [,R23=] [,L3PS=] [,TRACE=] [,N2WC=]; SET ACK: Successful SET NACK: NACK CAUSES: UNSUCCESSFUL_OBJECT_NOTEQUIPPED The object instance must be already equipped. UNSUCCESSFUL_INVALID_ATTRIBUTES Make reference to APPLICATION GUIDELINES n. 1 and n. 2. [(LCNIOC)...(LCNIOC+NIOC-1)] not intersected to (only for NIOC!=0) [(LCN2WC)...(LCN2WC+N2WC-1)] not intersected to (only for N2WC!=0) [(LCNOOC)...(LCNOOC+NOOC-1)] not intersected to (only for NOOC!=0) [(PVC)] E.g LCNIOC=1, NIOC=3 LCN2WC=4, N2WC=6 LCNOOC=10,NOOC=7 PVC=17 1436 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Example of Command Execution Set X25D:NAME=X25D:0,T1=27,T4=200,RETRY=8,L2WIN=1,LCN2WC=1, L3WIN=1,T20=1000,T21=1000,T22=1800,T23=3000,T26=400,T28=600, R20=255,R22=4,R23=10,L3PS=Packet_512,TRACE=0101010101 A30808-X3247-L230-3-7619 1437 Commands Base Station Controller CML:BSC 3 BTS and TRAU Objects and Commands BTSE The BTSE IW(InterWorking) icon allows the operator to have access to the containment sub-tree of the 1st generation BTS equipment, to perform the interworking commands. The following types of BTS equipment can be selected: BS-20 BS-21E BS-22 BS-60 BS-61E. The BTSEobjects and the related commands, available for the user fromBSC, are listed below. ACDC ACOM i For all BTS commands, if the user has selected a BTS family interface (e.g BTSEP) and then in the related commands he uses a BTS instance that refers to a BTS belonging to another BTS family (e.g. BS-242), the following Nack Cause is displayed: SWLOAD_NOT_BELONG_TO_BTSE. i The BTSE, BTSEP, BTSEPICO, BTSEEMand BTSEXS icons allow the user to access to two different containment sub-trees, one belonging to BR6.x release and the other belonging to BR7.0 release (this is due to the fact that the SW of the BR7.0 BSC is backward compatible with BTS BR6.x SW Versions). The two sub-trees are identical, except for the new objects (e.g. SDULNA, SDUSEC, SDUSUBSEC, SDUTXSW) which have been introduced in BR7.0 release. The BTSECicon allowthe user to access the containment tree related to the BTS equip- ment supporting TD-SCDMA; in this case only the BR7.0 interworkng tree can be opened, because the BTSEC is not supported in BR6.x release. Managed Element Phase 1 Phase 2 CREATE ACDC DELETE ACDC GET ACDC GETTEST ACDC LOCK ACDC PERFTEST ACDC STOPTEST ACDC UNLOCK ACDC CREATE ACOM DELETE ACOM GET ACOM 1438 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GETTEST ACOM LOCK ACOM PERFTEST ACOM A30808-X3247-L230-3-7619 1439 Commands Base Station Controller CML:BSC ACOM (cont.) ALCO BBSIG BPORT BTSE BTSETEST Managed Element Phase 1 Phase 2 SET ACOM STOPTEST ACOM UNLOCK ACOM GET ALCO GETTEST ALCO LOCK ALCO PERFTEST ALCO STOPTEST ALCO UNLOCK ALCO CREATE BBSIG DELETE BBSIG GET BBSIG GETTEST BBSIG LOCK BBSIG PERFTEST BBSIG SET BBSIG STOPTEST BBSIG UNLOCK BBSIG CREATE BPORT DELETE BPORT GET BPORT LOCK BPORT SET BPORT UNLOCK BPORT GET BTSE NOSWL GET BTSE SWL GETACTIVEALARMS BTSE PERFTEST BTSE SET BTSE STOPTEST BTSE GET BTSETEST 1440 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller CCLK CCTRL ENVABTSE FAN FTNF FVSWR Managed Element Phase 1 Phase 2 GET CCLK GET CCTRL CREATE ENVABTSE DELETE ENVABTSE GET ENVABTSE LOCK ENVABTSE SET ENVABTSE UNLOCK ENVABTSE CREATE FAN DELETE FAN GET FAN GETTEST FAN LOCK FAN PERFTEST FAN STOPTEST FAN UNLOCK FAN CREATE FTNF DELETE FTNF GET FTNF GETTEST FTNF LOCK FTNF PERFTEST FTNF STOPTEST FTNF UNLOCK FTNF CREATE FVSWR DELETE FVSWR GET FVSWR GETTEST FVSWR LOCK FVSWR PERFTEST FVSWR STOPTEST FVSWR UNLOCK FVSWR A30808-X3247-L230-3-7619 1441 Commands Base Station Controller CML:BSC GPSU LAPDLE LI LMT-INTERNAL PA RACK Managed Element Phase 1 Phase 2 GET GPSU CREATE LAPDLE DELETE LAPDLE GET LAPDLE GET LI SET LI ECHO EXEC SET CREATE PA DELETE PA GET PA GETTEST PA LOCK PA PERFTEST PA STOPTEST PA UNLOCK PA GET RACK 1442 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller RXAMOD RXMUCO TPU XCONNECT Managed Element Phase 1 Phase 2 CREATE RXAMOD DELETE RXAMOD GET RXAMOD GETTEST RXAMOD LOCK RXAMOD PERFTEST RXAMOD STOPTEST RXAMOD UNLOCK RXAMOD CREATE RXMUCO DELETE RXMUCO GET RXMUCO GETTEST RXMUCO LOCK RXMUCO PERFTEST RXMUCO SET RXMUCO STOPTEST RXMUCO UNLOCK RXMUCO CREATE TPU DELETE TPU GET TPU GETTEST TPU LOCK TPU PERFTEST TPU SET TPU STOPTEST TPU UNLOCK TPU CREATE XCONNECT DELETE XCONNECT GET XCONNECT LOCK XCONNECT SET XCONNECT UNLOCK XCONNECT A30808-X3247-L230-3-7619 1443 Commands Base Station Controller CML:BSC BTSEP The BTSEP IW (InterWorking) icon allows the operator to have access to the contain- ment sub-tree of the BTS Plus equipment, to perform the interworking commands. The following types of BTS equipment can be selected: BS-240 BS-241 BS-240XL BS-40 BS-41. The BTSEP objects and the related commands, available for the user from BSC, are listed below. ACDCP ACT BATTERY Managed Element Phase 1 Phase 2 CREATE ACDCP DELETE ACDCP GET ACDCP GETTEST ACDCP LOCK ACDCP PERFTEST ACDCP STOPTEST ACDCP UNLOCK ACDCP CREATE ACT DELETE ACT GET ACT GETTEST ACT LOCK ACT PERFTEST ACT STOPTEST ACT UNLOCK ACT CREATE BATTERY DELETE BATTERY GET BATTERY GETTEST BATTERY LOCK BATTERY PERFTEST BATTERY STOPTEST BATTERY UNLOCK BATTERY 1444 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BPORT BTSEP BTSETEST COBA COSA Managed Element Phase 1 Phase 2 CREATE BPORT DELETE BPORT GET BPORT LOCK BPORT SET BPORT UNLOCK BPORT GET BTSEP NOSWL GET BTSEP SWL GETACTIVEALARMS BTSEP PERFTEST BTSEP SET BTSEP STOPTEST BTSEP GET BTSETEST CREATE COBA DELETE COBA GET COBA GETTEST COBA LOCK COBA PERFTEST COBA SET COBA STOPTEST COBA SWITCH COBA UNLOCK COBA CREATE COSA DELETE COSA GET COSA GETTEST COSA LOCK COSA PERFTEST COSA STOPTEST COSA UNLOCK COSA A30808-X3247-L230-3-7619 1445 Commands Base Station Controller CML:BSC CU DIDCTMA DILNA DUDCTMA Managed Element Phase 1 Phase 2 CREATE CU DELETE CU GET CU GETTEST CU LOCK CU PERFTEST CU SET CU STOPTEST CU UNLOCK CU CREATE DIDCTMA DELETE DIDCTMA GET DIDCTMA GETTEST DIDCTMA LOCK DIDCTMA PERFTEST DIDCTMA STOPTEST DIDCTMA UNLOCK DIDCTMA CREATE DILNA DELETE DILNA GET DILNA GETTEST DILNA LOCK DILNA PERFTEST DILNA SET DILNA STOPTEST DILNA UNLOCK DILNA CREATE DUDCTMA DELETE DUDCTMA GET DUDCTMA GETTEST DUDCTMA LOCK DUDCTMA PERFTEST DUDCTMA STOPTEST DUDCTMA UNLOCK DUDCTMA 1446 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DULNA DUVSWR ENVABTSE FANP Managed Element Phase 1 Phase 2 CREATE DULNA DELETE DULNA GET DULNA GETTEST DULNA LOCK DULNA PERFTEST DULNA SET DULNA STOPTEST DULNA UNLOCK DULNA CREATE DUVSWR DELETE DUVSWR GET DUVSWR GETTEST DUVSWR LOCK DUVSWR PERFTEST DUVSWR SET DUVSWR STOPTEST DUVSWR UNLOCK DUVSWR CREATE ENVABTSE DELETE ENVABTSE GET ENVABTSE LOCK ENVABTSE SET ENVABTSE UNLOCK ENVABTSE CREATE FANP DELETE FANP GET FANP GETTEST FANP LOCK FANP PERFTEST FANP STOPTEST FANP UNLOCK FANP A30808-X3247-L230-3-7619 1447 Commands Base Station Controller CML:BSC FTNFP FVSWRP LAPDLE LMT-INTERNAL LMU Managed Element Phase 1 Phase 2 CREATE FTNFP DELETE FTNFP GET FTNFP GETTEST FTNFP LOCK FTNFP PERFTEST FTNFP STOPTEST FTNFP UNLOCK FTNFP CREATE FVSWRP DELETE FVSWRP GET FVSWRP GETTEST FVSWRP LOCK FVSWRP PERFTEST FVSWRP STOPTEST FVSWRP UNLOCK FVSWRP CREATE LAPDLE DELETE LAPDLE GET LAPDLE ECHO EXEC SET CREATE LMU DELETE LMU GET LMU GETTEST LMU LOCK LMU PERFTEST LMU STOPTEST LMU UNLOCK LMU 1448 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller RACK SDULNA SDUSEC SDUSUBSEC SDUTXSW Managed Element Phase 1 Phase 2 CREATE RACK DELETE RACK GET RACK LOCK RACK UNLOCK RACK CREATE SDULNA DELETE SDULNA GET SDULNA GETTEST SDULNA LOCK SDULNA PERFTEST SDULNA STOPTEST SDULNA UNLOCK SDULNA CREATE SDUSEC DELETE SDUSEC GET SDUSEC GETTEST SDUSEC LOCK SDUSEC PERFTEST SDUSEC STOPTEST SDUSEC UNLOCK SDUSEC CREATE SDUSUBSEC DELETE SDUSUBSEC GET SDUSUBSEC GETTEST SDUSUBSEC LOCK SDUSUBSEC PERFTEST SDUSUBSEC SET SDUSUBSEC STOPTEST SDUSUBSEC UNLOCK SDUSUBSEC CREATE SDUTXSW DELETE SDUTXSW GET SDUTXSW GETTEST SDUTXSW A30808-X3247-L230-3-7619 1449 Commands Base Station Controller CML:BSC SDUTXSW (cont.) TMA XCONNECT Managed Element Phase 1 Phase 2 LOCK SDUTXSW PERFTEST SDUTXSW STOPTEST SDUTXSW UNLOCK SDUTXSW CREATE TMA DELETE TMA GET TMA GETTEST TMA LOCK TMA PERFTEST TMA STOPTEST TMA UNLOCK TMA CREATE XCONNECT DELETE XCONNECT GET XCONNECT LOCK XCONNECT SET XCONNECT UNLOCK XCONNECT 1450 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BTSEPICO The BTSEPICO IW (InterWorking) icon allows the operator to have access to the containment sub-tree of the BTS PICOequipment (BS-242), to performthe interworking commands. The BTSEPICOobjects and the related commands, available for the user fromBSC, are listed below. ACDCP ACT BATTERY Managed Element Phase 1 Phase 2 CREATE ACDCP DELETE ACDCP GET ACDCP GETTEST ACDCP LOCK ACDCP PERFTEST ACDCP STOPTEST ACDCP UNLOCK ACDCP CREATE ACT DELETE ACT GET ACT GETTEST ACT LOCK ACT PERFTEST ACT STOPTEST ACT UNLOCK ACT CREATE BATTERY DELETE BATTERY GET BATTERY GETTEST BATTERY LOCK BATTERY PERFTEST BATTERY STOPTEST BATTERY UNLOCK BATTERY A30808-X3247-L230-3-7619 1451 Commands Base Station Controller CML:BSC BPORT BTSEPICO BTSETEST CA CCINT Managed Element Phase 1 Phase 2 CREATE BPORT DELETE BPORT GET BPORT LOCK BPORT SET BPORT UNLOCK BPORT GET BTSEPICO NOSWL GET BTSEPICO SWL GETACTIVEALARMS BTSEPICO PERFTEST BTSEPICO SET BTSEPICO STOPTEST BTSEPICO GET BTSETEST CREATE CA DELETE CA GET CA GETTEST CA LOCK CA PERFTEST CA SET CA STOPTEST CA UNLOCK CA CREATE CCINT DELETE CCINT GET CCINT GETTEST CCINT LOCK CCINT PERFTEST CCINT STOPTEST CCINT UNLOCK CCINT 1452 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller CCSLINK COBA COSA DCREFE Managed Element Phase 1 Phase 2 CREATE CCSLINK DELETE CCSLINK GET CCSLINK GETTEST CCSLINK LOCK CCSLINK PERFTEST CCSLINK SET CCSLINK STOPTEST CCSLINK UNLOCK CCSLINK CREATE COBA DELETE COBA GET COBA GETTEST COBA LOCK COBA PERFTEST COBA SET COBA STOPTEST COBA SWITCH COBA UNLOCK COBA CREATE COSA DELETE COSA GET COSA GETTEST COSA LOCK COSA PERFTEST COSA STOPTEST COSA UNLOCK COSA CREATE DCREFE DELETE DCREFE GET DCREFE GETTEST DCREFE LOCK DCREFE PERFTEST DCREFE STOPTEST DCREFE UNLOCK DCREFE A30808-X3247-L230-3-7619 1453 Commands Base Station Controller CML:BSC ENVABTSE FANP LAPDLE LMT-INTERNAL RACK XCONNECT Managed Element Phase 1 Phase 2 CREATE ENVABTSE DELETE ENVABTSE GET ENVABTSE LOCK ENVABTSE SET ENVABTSE UNLOCK ENVABTSE CREATE FANP DELETE FANP GET FANP GETTEST FANP LOCK FANP PERFTEST FANP STOPTEST FANP UNLOCK FANP CREATE LAPDLE DELETE LAPDLE GET LAPDLE ECHO EXEC SET GET RACK CREATE XCONNECT DELETE XCONNECT GET XCONNECT LOCK XCONNECT SET XCONNECT UNLOCK XCONNECT 1454 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BTSEEM The BTSEEM IW (InterWorking) icon allows the operator to have access to the containment sub-tree of the BTS Enhanced Micro (BS-82) equipment, to perform the interworking commands. The BTSEEM objects and the related commands, available for the user from BSC, are listed below. ACDCP ACT BATTERY Managed Element Phase 1 Phase 2 CREATE ACDCP DELETE ACDCP GET ACDCP GETTEST ACDCP LOCK ACDCP PERFTEST ACDCP STOPTEST ACDCP UNLOCK ACDCP CREATE ACT DELETE ACT GET ACT GETTEST ACT LOCK ACT PERFTEST ACT STOPTEST ACT UNLOCK ACT CREATE BATTERY DELETE BATTERY GET BATTERY GETTEST BATTERY LOCK BATTERY PERFTEST BATTERY STOPTEST BATTERY UNLOCK BATTERY A30808-X3247-L230-3-7619 1455 Commands Base Station Controller CML:BSC BPORT BTSEEM BTSETEST COBA CU Managed Element Phase 1 Phase 2 CREATE BPORT DELETE BPORT GET BPORT LOCK BPORT SET BPORT UNLOCK BPORT GET BTSEEM NOSWL GET BTSEEM SWL GETACTIVEALARMS BTSEEM PERFTEST BTSEEM SET BTSEEM STOPTEST BTSEEM GET BTSETEST GET COBA SET COBA CREATE CU DELETE CU GET CU GETTEST CU LOCK CU PERFTEST CU SET CU STOPTEST CU UNLOCK CU 1456 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DILNA DULNA DUVSWR ENVABTSE Managed Element Phase 1 Phase 2 CREATE DILNA DELETE DILNA GET DILNA GETTEST DILNA LOCK DILNA PERFTEST DILNA SET DILNA STOPTEST DILNA UNLOCK DILNA CREATE DULNA DELETE DULNA GET DULNA GETTEST DULNA LOCK DULNA PERFTEST DULNA STOPTEST DULNA UNLOCK DULNA CREATE DUVSWR DELETE DUVSWR GET DUVSWR GETTEST DUVSWR LOCK DUVSWR PERFTEST DUVSWR SET DUVSWR STOPTEST DUVSWR UNLOCK DUVSWR CREATE ENVABTSE DELETE ENVABTSE GET ENVABTSE LOCK ENVABTSE SET ENVABTSE UNLOCK ENVABTSE A30808-X3247-L230-3-7619 1457 Commands Base Station Controller CML:BSC FANP LAPDLE LMT-INTERNAL RACK XCONNECT Managed Element Phase 1 Phase 2 CREATE FANP DELETE FANP GET FANP GETTEST FANP LOCK FANP PERFTEST FANP STOPTEST FANP UNLOCK FANP CREATE LAPDLE DELETE LAPDLE GET LAPDLE ECHO EXEC SET CREATE RACK DELETE RACK GET RACK LOCK RACK UNLOCK RACK CREATE XCONNECT DELETE XCONNECT GET XCONNECT LOCK XCONNECT SET XCONNECT UNLOCK XCONNECT 1458 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BTSEXS The BTSEXS IW (InterWorking) icon allows the operator to have access to the containment sub-tree of the BS-240XS equipment, to perform the interworking commands. The BTSEXS object and the related commands, available for the user from BSC, are listed below. BCOM BPORT BTSETEST BTSEXS COBA Managed Element Phase 1 Phase 2 GET BCOM GETTEST BCOM LOCK BCOM PERFTEST BCOM STOPTEST BCOM UNLOCK BCOM CREATE BPORT DELETE BPORT GET BPORT LOCK BPORT SET BPORT UNLOCK BPORT GET BTSETEST GET BTSEXS NOSWL GET BTSEXS SWL GETACTIVEALARMS BTSEXS PERFTEST BTSEXS SET BTSEXS STOPTEST BTSEXS GET COBA SET COBA A30808-X3247-L230-3-7619 1459 Commands Base Station Controller CML:BSC CU ENVABTSE FANP LAPDLE LMT-INTERNAL Managed Element Phase 1 Phase 2 CREATE CU DELETE CU GET CU GETTEST CU LOCK CU PERFTEST CU SET CU STOPTEST CU UNLOCK CU CREATE ENVABTSE DELETE ENVABTSE GET ENVABTSE LOCK ENVABTSE SET ENVABTSE UNLOCK ENVABTSE CREATE FANP DELETE FANP GET FANP GETTEST FANP LOCK FANP PERFTEST FANP STOPTEST FANP UNLOCK FANP CREATE LAPDLE DELETE LAPDLE GET LAPDLE ECHO EXEC SET 1460 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller LMU RACK XCONNECT Managed Element Phase 1 Phase 2 CREATE LMU DELETE LMU GET LMU GETTEST LMU LOCK LMU PERFTEST LMU STOPTEST LMU UNLOCK LMU GET RACK CREATE XCONNECT DELETE XCONNECT GET XCONNECT LOCK XCONNECT SET XCONNECT UNLOCK XCONNECT A30808-X3247-L230-3-7619 1461 Commands Base Station Controller CML:BSC BTSEC The BTSEC IW (InterWorking) icon allows the operator to have access to the contain- ment sub-tree of the BTS equipment that provides TD-SCDMA functionality, to perform the interworking commands. The BTSEC objects and the related commands, available for the user from BSC, are listed below. ACT ANTENNA BPORT Managed Element Phase 1 Phase 2 CREATE ACT DELETE ACT GET ACT GETTEST ACT LOCK ACT PERFTEST ACT STOPTEST ACT UNLOCK ACT CREATE ANTENNA DELETE ANTENNA GET ANTENNA GETTEST ANTENNA LOCK ANTENNA SET ANTENNA PERFTEST ANTENNA STOPTEST ANTENNA UNLOCK ANTENNA CREATE BPORT DELETE BPORT GET BPORT LOCK BPORT SET BPORT UNLOCK BPORT 1462 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BTSEC BTSETEST COBA COSA Managed Element Phase 1 Phase 2 GET BTSEC NOSWL GET BTSEC SWL GETACTIVEALARMS BTSEC PERFTEST BTSEC SET BTSEC STOPTEST BTSEC GET BTSETEST CREATE COBA DELETE COBA GET COBA GETTEST COBA LOCK COBA PERFTEST COBA SET COBA STOPTEST COBA SWITCH COBA UNLOCK COBA CREATE COSA DELETE COSA GET COSA GETTEST COSA LOCK COSA PERFTEST COSA STOPTEST COSA UNLOCK COSA A30808-X3247-L230-3-7619 1463 Commands Base Station Controller CML:BSC ENVABTSE FANP GPS LAPDLE LMT-INTERNAL Managed Element Phase 1 Phase 2 CREATE ENVABTSE DELETE ENVABTSE GET ENVABTSE LOCK ENVABTSE SET ENVABTSE UNLOCK ENVABTSE CREATE FANP DELETE FANP GET FANP GETTEST FANP LOCK FANP PERFTEST FANP STOPTEST FANP UNLOCK FANP CREATE GPS DELETE GPS GET GPS GETTEST GPS LOCK GPS PERFTEST GPS SET GPS STOPTEST GPS UNLOCK GPS CREATE LAPDLE DELETE LAPDLE GET LAPDLE ECHO EXEC SET 1464 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller LNA MCPA RACK REMINV RFMAIN Managed Element Phase 1 Phase 2 CREATE LNA DELETE LNA GET LNA GETTEST LNA LOCK LNA PERFTEST LNA STOPTEST LNA UNLOCK LNA CREATE MCPA DELETE MCPA GET MCPA GETTEST MCPA LOCK MCPA PERFTEST MCPA STOPTEST MCPA UNLOCK MCPA GET RACK DNLIDFD REMINV UPLLIDF REMINV CREATE RFMAIN DELETE RFMAIN GET RFMAIN GETTEST RFMAIN LOCK RFMAIN PERFTEST RFMAIN STOPTEST RFMAIN UNLOCK RFMAIN A30808-X3247-L230-3-7619 1465 Commands Base Station Controller CML:BSC RFRXPATH RFTXPATH SIPROC Managed Element Phase 1 Phase 2 CREATE RFRXPATH DELETE RFRXPATH GET RFRXPATH GETTEST RFRXPATH LOCK RFRXPATH PERFTEST RFRXPATH STOPTEST RFRXPATH UNLOCK RFRXPATH CREATE RFTXPATH DELETE RFTXPATH GET RFTXPATH GETTEST RFTXPATH LOCK RFTXPATH PERFTEST RFTXPATH STOPTEST RFTXPATH UNLOCK RFTXPATH CREATE SIPROC DELETE SIPROC GET SIPROC GETTEST SIPROC LOCK SIPROC PERFTEST SIPROC STOPTEST SIPROC UNLOCK SIPROC 1466 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SWIPAMAIN SYNCBTSC XCONNECT Managed Element Phase 1 Phase 2 CREATE SWIPAMAIN DELETE SWIPAMAIN GET SWIPAMAIN GETTEST SWIPAMAIN LOCK SWIPAMAIN PERFTEST SWIPAMAIN STOPTEST SWIPAMAIN UNLOCK SWIPAMAIN CREATE SYNCBTSC DELETE SYNCBTSC GET SYNCBTSC LOCK SYNCBTSC SET SYNCBTSC UNLOCK SYNCBTSC CREATE XCONNECT DELETE XCONNECT GET XCONNECT LOCK XCONNECT SET XCONNECT UNLOCK XCONNECT A30808-X3247-L230-3-7619 1467 Commands Base Station Controller CML:BSC TRAUE The TRAUE IW (InterWorking) icon allows the operator to have access to the containment sub-tree of the TRAU equipment, to perform the interworking commands. The TRAUE objects and the related commands available for the user from BSC are listed below. BSMS ENVATRAUE LMT-INTERNAL TPWR i The number of TRAUs needed to achieve the target data of switching capacity of 3500 Erlang, maintaining the balancing between Abis and Asub configuration (maximum of 72 total PCM lines), is 32. Anyway, considering the further evolution and that no drawbacks are foreseen in case of upper limit, the maximum number of TRAUs is already set at 36. Managed Element Phase 1 Phase 2 FORMAT BSMS EPROM GET BSMS GETSUBO BSMS GETTEST BSMS LOCK BSMS PERFTEST BSMS STOPTEST BSMS SWITCH BSMS UNLOCK BSMS CREATE ENVATRAUE DELETE ENVATRAUE GET ENVATRAUE LOCK ENVATRAUE SET ENVATRAUE UNLOCK ENVATRAUE ECHO EXEC SET GET TPWR GETSUBO TPWR GETTEST TPWR LOCK TPWR 1468 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TPWR (cont.) TRAC TRAU TRAUE TRAUETEST Managed Element Phase 1 Phase 2 PERFTEST TPWR STOPTEST TPWR UNLOCK TPWR CREATE TRAC DELETE TRAC GET TRAC GETSUBO TRAC GETTEST TRAC LOCK TRAC PERFTEST TRAC STOPTEST TRAC UNLOCK TRAC ACTIVATE TRAU GET TRAUE GETACTIVEALARMS TRAUE PERFTEST TRAUE SET TRAUE STOPTEST TRAUE i The GETACTIVEALARMS command brings different results at BSC side (interworking LMT command) and TRAU side (local LMT command). The TRAU LMT must be used to have all the TRAU active alarms. GET TRAUETEST A30808-X3247-L230-3-7619 1469 Commands Base Station Controller CML:BSC 4 Parameters/Attributes in Alphabetical Order ABISCH - GTXINT ABISCH ABISHRACTTHR This attribute identifies the PCMslot allocated for the LapD signalling link, for O&M messages, at the Abis interface. When this parameter is used with LPDLR/LPDLRTD object, it identi- fies the physical lapd_link (LPDLM/LPDLMTD) which the LPDLR/LPDLRTD created is mapped to. The slot can be configured as a 64 kbit/s timeslot (the subslot field is skipped), or as a 16 kbit/s timeslot (the subslot field is to be configured). This parameter consists of the three fields: PcmbNumber, TSL (TimeSlotNumber) and SSN (SubSlotNumber). Validity range: PcmbNumber 0..117 Tsl 1..31 for PCM30 line 1..24 for PCM24 line Ssl 0..3 (default value: NOCONFIG) Contained in the following commands: CREATE LPDLM, GET LPDLM, CREATE LPDLMTD, GET LPDLMTD This parameter defines the threshold that indicates the percentage of busy Abis subslots (fully busy + half busy + out of service) in the Abis pool that triggers the Cell Load Dependent Activation of Half Rate in all the cells of the site where the feature is enabled. Validity range: abisHalfRateActivationThreshold 0..100 <NULL> (default value: 60) Contained in the following commands: CREATE BTSM, GET BTSM, SET BTSM, CREATE BTSMTD, GET BTSMTD, SET BTSMTD 1470 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller ABISTRFHITHR ABISTRFLTHR ABORT ABUTYP This parameter defines the Abis high traffic level threshold. In combination with the TRFHITH parameter, it is used to establish if handover for traffic reason has to be enabled/disabled. When the percentage of busy Abis subslots in the BTSM overcomes the value of the parameter, handover for traffic reason is enabled in all the BTSs of the site for which TRFHOE is equal to TRUE. In such a case, if an handover for traffic reason is requested to BSC, it is performed towards a different BTSM. Validity range: abisTrafficHighThreshold 50..100 <NULL> (default value: 90) Contained in the following commands: CREATE BTSM, GET BTSM, SET BTSM This parameter defines the Abis low traffic level in order to establish if a BTSM can be candidate to receive handover for traffic reason. Validity range: abisTrafficLowThreshold 0..80 <NULL> (default value: 70) Contained in the following commands: CREATE BTSM, GET BTSM, SET BTSM This attribute defines whether scripts have to abort or not after a FALSE command (NACK-replied BMML command or failed TEST command). Validity range: YES NO Contained in the following commands: SET, EXEC; This parameter indicates the type of access burst used on uplink PDCH. The value ACBU8BIT means that 8 bits access burst shall be used by mobile station and ACBU11BIT means that 11 bits access burst shall be used by mobile station. Validity range: accessBurstType ACBU11BIT ACBU8BIT <DEFAULT> (default value: ACBU8BIT) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF A30808-X3247-L230-3-7619 1471 Commands Base Station Controller CML:BSC ACCEPTGDEGR ACCTYP ACHAN ACTN This attribute defines, in percentage, the acceptable degradation of packet service throughput (Maximum Sustainable Throughput), before an upgrading of radio resources is attempted. Validity range: acceptableGPRSDegradation PER0 PER10 PER20 PER30 PER40 PER50 PER60 PER70 PER80 PER90 <DEFAULT> (default value: PER0) Contained in the following commands: GET BSC, SET BSC This attribute identifies the reading format. Validity range: accessType BYTE, WORD, DWORD (default value: BYTE) Contained in the following commands: MEMDUMP BSC It indicates the pcma line number and the timeslot number used on the "PCMA Interface". Validity range: PcmaNumber 0..143 TslNumber 1-31 for PCM30 line 1-24 for PCM24 line Contained in the following commands: CREATE X25A, GET X25A This parameter defines the BSC Operating Software Unit attribute which must be set. Validity range: action RUNNING_ESU BACKUP_ESU NEW_ESU FALLBACK_ESU Contained in the following commands: SET BSCOSUDB, SET BSCOSUSW 1472 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller AISAT ALACOUNT ALARMT1 ALARMT2 ALARMT3 This attribute indicates whether the LAPD link on the A interface is satellited or terrestrial. Validity range: aInterfacelsSatellited FALSE TRUE (default value:FALSE) Contained in the following commands: GET BSC, SET BSC Threshold of the N alarm count. Validity range: alarmCount 1..254 <DEFAULT> (default value: 32) Contained in the following commands: CREATE LICD, GET LICD, SET LICD Threshold of the T1 alarm timer. Validity range: alarmTiming1 2..254 (0,1 s step size) <DEFAULT> (default value: 200 [20 s]) Contained in the following commands: CREATE LICD, GET LICD, SET LICD Threshold of the T2 alarm timer. Validity range: alarmTiming2 2..254 (0,1 s step size) <DEFAULT> (default value: 10 [1 s]) Contained in the following commands: CREATE LICD, GET LICD, SET LICD Threshold of the T3 alarm timer. Validity range: alarmTiming3 1..254 (5 minutes step size) <DEFAULT> (default value: 1) Contained in the following commands: CREATE LICD, GET LICD, SET LICD A30808-X3247-L230-3-7619 1473 Commands Base Station Controller CML:BSC ALEVFULHO ALLCRIT ALPHA This is an optional parameter that can be set in the Hand Basic Attribute Group. It defines two averaging parameters for FUHO (Fast Uplink Handover) signal strength measurements, used for fast uplink handover decision. The first field, aLevFuHo, defines the averaging window size (that is smaller than the normal window size), the second one, wLevFuho, indicates the averaging weighting factor. Validity range: averagedLevFastULHo <NULL> ALevFuHo 1..31 (default value: 2) WLevFuHo 1..3 (default value: 1) Contained in the following commands: GET HAND, SET HAND This attribute defines the rule to be used for the transcoder matrix computation. The NOT_COMPATIBLE_WITH_CROSSCONNECT value can be chosen when Cross Connectors between BSC and TRAU are not used. The COMPATIBLE_WITH_CROSSCONNECT value has to be chosen when Cross Connectors between BSC and TRAU are used; that means that timeslots belonging to the same PCMA are mapped onto 8 consecutive PCMS timeslots. Validity range: allocationCriteria NOT_COMPATIBLE_WITH_CROSSCONNECT COMPATIBLE_WITH_CROSS_CONNECT <DEFAULT> (default value: NOT_COMPATIBLE_WITH_CROSSCONNECT) Contained in the following commands: CREATE TRAU, GET TRAU This attribute indicates the ALPHA value applied in the power control algorithm. The step size is 0.1; the value 0 corresponds to 0.0 and the value 10 corresponds to 1.0. Validity range: alpha 0..10 (0.1 step size) <DEFAULT> (default value: 3) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF 1474 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller ALPHATD ALRMSEVBTS ALRMSEVBTSM ALRMSEVBTSMTD This attribute indicates the ALPHA value applied in the power control algorithm. The step size is 0.1; the value 0 corresponds to 0.0 and the value 10 corresponds to 1.0. Validity range: alphaTD 0..10 (0.1 step size) <DEFAULT> (default value: 3) Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD This attribute indicates the alarm severity associated to BTS functional object. Validity range: alarmSeverityBts CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: CRITICAL) Contained in the following commands: GET BSC, SET BSC This attribute indicates the alarm severity associated to BTSM functional object. Validity range: alarmSeverityBtsm CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSC, SET BSC This attribute indicates the alarm severity associated to BTSMTD functional object. Validity range: alarmSeverityBtsmtd CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSC, SET BSC A30808-X3247-L230-3-7619 1475 Commands Base Station Controller CML:BSC ALRMSEVBTSTD ALRMSEVCBCL ALRMSEVCPEX ALRMSEVDISK ALRMSEVDK40 This attribute indicates the alarm severity associated to BTSTD functional object. Validity range: alarmSeverityBtstd CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: CRITICAL) Contained in the following commands: GET BSC, SET BSC This attribute indicates the alarm severity associated to CBCL functional object. Validity range: alarmSeverityCbcl CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSC, SET BSC This attribute indicates the alarm severity associated to CPEX equipment object. Validity range: alarmSeverityCPEX CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MINOR) Contained in the following commands: GET BSCE, SET BSCE This attribute indicates the alarm severity associated to DISK equipment object. Validity range: alarmSeverityDisk CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSCE, SET BSCE This attribute indicates the alarm severity associated to DK40 equipment object. Validity range: alarmSeverityDk40 CRITICAL, MAJOR, MINOR, <DEFAULT> 1476 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller ALRMSEVEPWR ALRMSEVFAN ALRMSEVFRL ALRMSEVIPLI (default value: MAJOR) Contained in the following commands: GET BSCE, SET BSCE This attribute indicates the alarm severity associated to EPWR equipment object. Validity range: alarmSeverityEpwr CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSCE, SET BSCE This attribute indicates the alarm severity associated to FAN equipment object. Validity range: alarmSeverityFAN CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MINOR) Contained in the following commands: GET BSCE, SET BSCE This attribute indicates the alarm severity associated to FRL functional object. Validity range: alarmSeverityFrl CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSC, SET BSC This attribute indicates the alarm severity associated to IPLI functional object. Validity range: alarmSeverityIpli CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSC, SET BSC A30808-X3247-L230-3-7619 1477 Commands Base Station Controller CML:BSC ALRMSEVIXLT ALRMSEVLICD ALRMSEVLICDS ALRMSEVLPDLM ALRMSEVLPDLMTD This attribute indicates the alarm severity associated to IXLT equipment object. Validity range: alarmSeverityIxlt CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSCE, SET BSCE This attribute indicates the alarm severity associated to LICD equipment object. Validity range: alarmSeverityLicd CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MINOR) Contained in the following commands: GET BSCE, SET BSCE This attribute indicates the alarm severity associated to LICDS equipment object. Validity range: alarmSeverityLicds CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MINOR) Contained in the following commands: GET BSCE, SET BSCE This attribute indicates the alarm severity associated to LPDLM functional object. Validity range: alarmSeverityLpdlm CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSC, SET BSC This attribute indicates the alarm severity associated to LPDLMTD functional object. Validity range: alarmSeverityLpdlm CRITICAL, MAJOR, MINOR, <DEFAULT> 1478 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller ALRMSEVLPDLR ALRMSEVLPDLRTD ALRMSEVLPDLS ALRMSEVMEMT (default value: MAJOR) Contained in the following commands: GET BSC, SET BSC This attribute indicates the alarm severity associated to LPDLR functional object. Validity range: alarmSeverityLpdlr CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: CRITICAL) Contained in the following commands: GET BSC, SET BSC This attribute indicates the alarm severity associated to LPDLRTD functional object. Validity range: alarmSeverityLpdlrtd CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: CRITICAL) Contained in the following commands: GET BSC, SET BSC This attribute indicates the alarm severity associated to LPDLS functional object. Validity range: alarmSeverityLpdls CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSC, SET BSC This attribute indicates the alarm severity associated to MEMT equipment object. Validity range: alarmSeverityMemt CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSCE, SET BSCE A30808-X3247-L230-3-7619 1479 Commands Base Station Controller CML:BSC ALRMSEVMPCC ALRMSEVNSVC ALRMSEVNTW ALRMSEVOMAL ALRMSEVPCMA This attribute indicates the alarm severity associated to MPCC equipment object. Validity range: alarmSeverityMpcc CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSCE, SET BSCE This attribute indicates the alarm severity associated to NSVC functional object. Validity range: alarmSeverityNsvc CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSC, SET BSC This attribute indicates the alarm severity associated to NTW equipment object. Validity range: alarmSeverityNtw CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSCE, SET BSCE This attribute indicates the alarm severity associated to OMAL functional object. Validity range: alarmSeverityOmal CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSC, SET BSC This attribute indicates the alarm severity associated to PCMA functional object. Validity range: alarmSeverityPcma CRITICAL, MAJOR, MINOR, <DEFAULT> 1480 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller ALRMSEVPCMB ALRMSEVPCMG ALRMSEVPCMS ALRMSEVPCU (default value: MAJOR) Contained in the following commands: GET BSC, SET BSC This attribute indicates the alarm severity associated to PCMB functional object. Validity range: alarmSeverityPcmb CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSC, SET BSC This attribute indicates the alarm severity associated to PCMG functional object. Validity range: alarmSeverityPcmg CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSC, SET BSC This attribute indicates the alarm severity associated to PCMS functional object. Validity range: alarmSeverityPcms CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSC, SET BSC This attribute indicates the alarm severity associated to PCU functional object. Validity range: alarmSeverityPcu CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSC, SET BSC A30808-X3247-L230-3-7619 1481 Commands Base Station Controller CML:BSC ALRMSEVPCUTD ALRMSEVPPCC ALRMSEVPPCU ALRMSEVPPLD ALRMSEVPPXL This attribute indicates the alarm severity associated to PCUTD functional object. Validity range: alarmSeverityPcutd CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: CRITICAL) Contained in the following commands: GET BSC, SET BSC This attribute indicates the alarm severity associated to PPCC equipment object. Validity range: alarmSeverityPpcc CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSCE, SET BSCE This attribute indicates the alarm severity associated to PPCU equipment object. Validity range: alarmSeverityPpcu CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSCE, SET BSCE This attribute indicates the alarm severity associated to PPLD equipment object. Validity range: alarmSeverityPpld CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MINOR) Contained in the following commands: GET BSCE, SET BSCE This attribute indicates the alarm severity associated to PPXL equipment object. Validity range: 1482 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller ALRMSEVPPXP ALRMSEVPPXT ALRMSEVPPXU ALRMSEVPTPPKF alarmSeverityPpxl CRITICAL, MAJOR, MINOR, <DEFAULT> Contained in the following commands: GET BSCE, SET BSCE This attribute indicates the alarm severity associated to PPXP equipment object. Validity range: alarmSeverityPpxp CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSCE, SET BSCE This attribute indicates the alarm severity associated to PPXT equipment object. Validity range: alarmSeverityPpxt CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSCE, SET BSCE This attribute indicates the alarm severity associated to PPXU equipment object. Validity range: alarmSeverityPpxu CRITICAL, MAJOR, MINOR, <DEFAULT> Contained in the following commands: GET BSCE, SET BSCE This attribute indicates the alarm severity associated to PTPPKF functional object. Validity range: alarmSeverityPtppkf CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSC, SET BSC A30808-X3247-L230-3-7619 1483 Commands Base Station Controller CML:BSC ALRMSEVPTPPKFTD ALRMSEVPWRD ALRMSEVSYNC ALRMSEVSYNE ALRMSEVTDCU This attribute indicates the alarm severity associated to PTPPKFTD functional object. Validity range: alarmSeverityPtppkftd CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSC, SET BSC This attribute indicates the alarm severity associated to PWRD equipment object. Validity range: alarmSeverityPwrd CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSCE, SET BSCE This attribute indicates the alarm severity associated to SYNC equipment object. Validity range: alarmSeveritySync CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSCE, SET BSCE This attribute indicates the alarm severity associated to SYNE equipment object. Validity range: alarmSeveritySyne CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSCE, SET BSCE This attribute indicates the alarm severity associated to TDCU functional object. Validity range: alarmSeverityTdcu CRITICAL, MAJOR, MINOR, <DEFAULT> 1484 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller ALRMSEVTDPC ALRMSEVTRAU ALRMSEVTRX ALRMSEVTRXTD (default value: CRITICAL) Contained in the following commands: GET BSC, SET BSC This attribute indicates the alarm severity associated to TDPC equipment object. Validity range: alarmSeverityTdpc CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSCE, SET BSCE This attribute indicates the alarm severity associated to TRAU functional object. Validity range: alarmSeverityTrau CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: CRITICAL) Contained in the following commands: GET BSC, SET BSC This attribute indicates the alarm severity associated to TRX functional object. Validity range: alarmSeverityTrx CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSC, SET BSC This attribute indicates the alarm severity associated to TRXTD functional object. Validity range: alarmSeverityTrxtd CRITICAL, MAJOR, MINOR, <DEFAULT> (default value: MAJOR) Contained in the following commands: GET BSC, SET BSC A30808-X3247-L230-3-7619 1485 Commands Base Station Controller CML:BSC ALRMSEVX25A ALRMSEVX25D ALTH AMONTH This attribute indicates the alarm severity associated to X25A equipment object. Validity range: alarmSeverityX25a CRITICAL, MAJOR, MINOR (default value: MAJOR) Contained in the following commands: GET BSCE, SET BSCE This attribute indicates the alarm severity associated to X25D equipment object. Validity range: alarmSeverityX25d CRITICAL, MAJOR, MINOR (default value: MAJOR) Contained in the following commands: GET BSCE, SET BSCE This parameter represents the alarm threshold. Validity range: alarmThreshold 14..100 dB <DEFAULT> (default value: 30 dB) Contained in the following commands: CREATE RFLOOP, GET RFLOOP, SET RFLOOP This attribute indicates the A-Int Monitor Thresholds for TSLA. The threshold is the percentage between out of service TSLA on equipped TSLA; that is: AMONTH = (TSLA out of service / TSLA equipped)*100 The threshold values can be assigned only when the flag attribute is set to enabled. Validity range: minor disabled 0..0 enabled 1..100 (default value: 30) major disabled 0..0 enabled 1..100 (default value: 60) critical disabled 0..0 enabled 1..100 (default value: 90) Contained in the following commands: GET BSC, SET BSC 1486 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller AMRACMRDL AMRFRC1 AMRFRC2 This parameter defines the size of the averaging window for Codec Mode Requests (CMRs) received from the MS during an AMR (Adaptive MultiRate) call. Parameter settings larger than 31 are resulting in a size of 31. In case of Satellites Links (Abis or Asub) the parameter is ignored. Validity range: aMRAveragedCMRDL 1..63 (1 CMR step size) <NULL> (default value: 5 CMR) Contained in the following commands: GET HAND, SET HAND This parameter indicates the first (most robust) AMR (Adaptive MultiRate) active codec in case of Full Rate codec. The following bit rate can be set: RATE_01 4.75 kbit/s RATE_02 5.15 kbit/s RATE_03 5.90 kbit/s RATE_04 6.70 kbit/s RATE_05 7.40 kbit/s RATE_06 7.95 kbit/s RATE_07 10.2 kbit/s RATE_08 12.2 kbit/s Validity range: aMRFullRateCodec1 RATE_01 RATE_02 RATE_03 RATE_04 RATE_05 RATE_06 RATE_07 RATE_08 <NULL> (default value: RATE_01 [4.75 kbit/s]) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE FHSY, GET FHSY, SET FHSY This parameter indicates the second AMR (Adaptive MultiRate) active codec in case of Full Rate codec. For the bit rate numerical values refer to AMRFRC1 parameter. Validity range: aMRFullRateCodec2 RATE_01 RATE_02 RATE_03 RATE_04 RATE_05 RATE_06 RATE_07 RATE_08 <NULL> A30808-X3247-L230-3-7619 1487 Commands Base Station Controller CML:BSC AMRFRC3 AMRFRC4 AMRFRIC (default value: RATE_03 [5.90 kbit/s]) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE FHSY, GET FHSY, SET FHSY This parameter indicates the third AMR (Adaptive MultiRate) active codec in case of Full Rate codec. For the bit rate numerical values refer to AMRFRC1 parameter. Validity range: aMRFullRateCodec3 RATE_01 RATE_02 RATE_03 RATE_04 RATE_05 RATE_06 RATE_07 RATE_08 <NULL> (default value: RATE_06 [7.95 kbit/s]) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE FHSY, GET FHSY, SET FHSY This parameter indicates the fourth (least robust) AMR (Adaptive MultiRate) active codec in case of Full Rate codec. For the bit rate numerical values refer to AMRFRC1 parameter. Validity range: aMRFullRateCodec4 RATE_01 RATE_02 RATE_03 RATE_04 RATE_05 RATE_06 RATE_07 RATE_08 <NULL> (default value: RATE_08 [12.2 kbit/s]) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE FHSY, GET FHSY, SET FHSY This parameter defines the Initial Codec Mode, i.e. the Full Rate active codec mode which must be sent at first during a call. START_MODE_FR value depends on the number of codec modes contained in the Active Codec Set, which is equal to the number of AMRFRCi attributes set at a value different from NULL. The rule is the following. If the Active Codec Set contains: 1 mode this is the Initial Codec Mode; 2 or 3 modes the Initial Codec Mode is the most robust mode of the set (i.e. the one with lowest bit rate); 1488 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller AMRFRTH12 AMRFRTH23 4 modes the Initial Codec Mode is the second most robust mode of the set (i.e. the one with second lowest bit rate). CODEC_MODE_0i value corresponds to AMRFRCi value. Validity range: aMRFullRateInitialCodec START_MODE_FR CODEC_MODE_01 CODEC_MODE_02 CODEC_MODE_03 CODEC_MODE_04 <NULL> (default value: START_MODE_FR) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE FHSY, GET FHSY, SET FHSY This parameter defines the couple threshold-hysteresis related to the active codecs specified in the AMRFRC1 and AMRFRC2 attributes in case of Full Rate codec. The numerical range for the threshold is 0 to 31.5 dB and for hysteresis is 0 to 7.5 dB. Validity range: aMRFullRateThresholds12 <NULL> threshold 0..63 (0.5 dB step size) (default value: 7 [3.5 dB]) hysteresis 0..15 (0.5 dB step size) (default value: 4 [2.0 dB]) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE FHSY, GET FHSY, SET FHSY This parameter defines the couple threshold-hysteresis related to the active codecs specified in the AMRFRC2 and AMRFRC3 attributes in case of Full Rate codec. The numerical range for the threshold is 0 to 31.5 dB and for hysteresis is 0 to 7.5 dB. Validity range: aMRFullRateThresholds23 <NULL> threshold 0..63 (0.5 dB step size) (default value: 12 [6.0 dB]) hysteresis 0..15 (0.5 dB step size) (default value: 4 [2.0 dB]) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE FHSY, GET FHSY, SET FHSY A30808-X3247-L230-3-7619 1489 Commands Base Station Controller CML:BSC AMRFRTH34 AMRHRC1 AMRHRC2 This parameter defines the couple threshold-hysteresis related to the active codecs specified in the AMRFRC3 and AMRFRC4 attributes in case of Full Rate codec. The numerical range for the threshold is 0 to 31.5 dB and for hysteresis is 0 to 7.5 dB. Validity range: aMRFullRateThresholds34 <NULL> threshold 0..63 (0.5 dB step size) (default value: 23 [11.5 dB]) hysteresis 0..15 (0.5 dB step size) (default value: 4 [2.0 dB]) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE FHSY, GET FHSY, SET FHSY This attribute indicates the first (most robust) AMR active codec in case of Half Rate codec. The following bit rate can be set: RATE_01 4.75 kbit/s RATE_02 5.15 kbit/s RATE_03 5.90 kbit/s RATE_04 6.70 kbit/s RATE_05 7.40 kbit/s Validity range: aMRHalfRateCodec1 RATE_01 RATE_02 RATE_03 RATE_04 RATE_05 <NULL> (default value: RATE_01 [4.75 kbit/s]) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE FHSY, GET FHSY, SET FHSY This attribute indicates the second AMR active codec in case of Half Rate codec. For the bit rate numerical values refer to AMRHRC1 parameter. Validity range: aMRHalfRateCodec2 RATE_01 RATE_02 RATE_03 RATE_04 RATE_05 <NULL> (default value: RATE_02 [5.15 kbit/s]) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE FHSY, GET FHSY, SET FHSY 1490 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller AMRHRC3 AMRHRC4 AMRHRIC This attribute indicates the third AMR active codec in case of Half Rate codec. For the bit rate numerical values refer to AMRHRC1 parameter. Validity range: aMRHalfRateCodec3 RATE_01 RATE_02 RATE_03 RATE_04 RATE_05 <NULL> (default value: RATE_03 [5.90 kbit/s]) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE FHSY, GET FHSY, SET FHSY This attribute indicates the fourth (least robust) AMR active codec in case of Half Rate codec. For the bit rate numerical values refer to AMRHRC1 parameter. Validity range: aMRHalfRateCodec4 RATE_01 RATE_02 RATE_03 RATE_04 RATE_05 <NULL> (default value: RATE_04 [6.70 kbit/s] for BTS+ family and <NULL> for BTSE type 1 family) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE FHSY, GET FHSY, SET FHSY This parameter defines the Initial Codec Mode, i.e. the Half Rate active codec mode which must be sent at first during a call. START_MODE_HR value depends on the number of codec modes contained in the Active Codec Set, which is equal to the number of AMRHRCi attributes set at a value different from NULL. The rule is the following. If the Active Codec Set contains: 1 mode this is the Initial Codec Mode; 2 or 3 modes the Initial Codec Mode is the most robust mode of the set (i.e. the one with lowest bit rate); 4 modes the Initial Codec Mode is the second most robust mode of the set (i.e. the one with second lowest bit rate). CODEC_MODE_0i value corresponds to AMRHRCi value. Validity range: aMRHRInitialCodec START_MODE_HR CODEC_MODE_01 CODEC_MODE_02 CODEC_MODE_03 A30808-X3247-L230-3-7619 1491 Commands Base Station Controller CML:BSC AMRHRTH12 AMRHRTH23 AMRHRTH34 CODEC_MODE_04 <NULL> (default value: START_MODE_HR) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE FHSY, GET FHSY, SET FHSY This attribute indicates the couple "threshold-hysteresis" related to the active codecs specified in the AMRHRC1 and AMRHRC2 attributes in case of Half Rate codec. Validity range: aMRHalfRateThresholds12 <NULL> threshold 0..63 (0.5 dB step size) (default value: 19 [9.5 dB]) hysteresis 0..15 (0.5 dB step size) (default value: 4 [2.0 dB]) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE FHSY, GET FHSY, SET FHSY This attribute indicates the couple "threshold-hysteresis" related to the active codecs specified in the AMRHRC2 and AMRHRC3 attributes in case of Half Rate codec. Validity range: aMRHalfRateThresholds23 <NULL> threshold 0..63 (0.5 dB step size) (default value: 24 [12.0 dB]) hysteresis 0..15 (0.5 dB step size) (default value: 4 [2.0 dB]) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE FHSY, GET FHSY, SET FHSY This attribute indicates the couple "threshold-hysteresis" related to the active codecs specified in the AMRHRC3 and AMRHRC4 attributes in case of Half Rate codec. Validity range: aMRHalfRateThresholds34 <NULL> threshold 0..63 (0.5 dB step size) (default value: 26 [13.0 dB for BTSP family and <NULL> for BTSE family) hysteresis 0..15 (0.5 dB step size) (default value: 4 [2.0 dB]) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE FHSY, GET FHSY, SET FHSY 1492 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller AMRLKAT ANTHOPMOD ANTHOPP This parameter is used by the AMR Uplink Codec Mode Adaptation in the BTS. It tunes the transition between codec modes determined by internal thresholds. A value higher than the default shifts the transition towards higher carrier-to-interferer ratios. A value lower than the default has the opposite effect. Adaptation of AMR Half Rate and AMRFull Rate is affected simultaneously. All possible transitions between modes are simultaneously shifted by the same amount. The default value is the optimum setting and normally requires no modification. Validity range: aMRLinkAdapTuning 0..200 (0.1 dB step size) where: 0 = -10 dB .. 200 = +10 dB <NULL> (default value: 100 [0 dB]) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter specifies whether the BCCH transceiver has to be included in the hopping sequence for Antenna Hopping or not. Validity range: antennaHoppingMode ALLTRX NOBCCHTRX <NULL> (default value: NOBCCHTRX) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter is used for Antenna Hopping and specifies how many frames are transmitted over each antenna before the next one is used to send the frames. The meaning of the values is the following: ALL Antenna Hopping is performed every frame; SECOND Antenna Hopping is performed every two frames; FOURTH Antenna Hopping is performed every four frames; SEQ_445 the 4-4-5 mode is set, which means that each 3rd Hopping step the period is extended from 4 to 5 frames. Validity range: antennaHoppingPeriod ALL SECOND FOURTH SEQ_445 <NULL> (default value: SECOND) Contained in the following commands: CREATE BTS, GET BTS, SET BTS A30808-X3247-L230-3-7619 1493 Commands Base Station Controller CML:BSC APLESSNBSC APLESSNSMLC ASCIONECHMDL ASCISER This parameter defines the SubsystemNumber for BSSAP-LE (Base Station System Application Part-LCS Extension) for BSC point of view. Validity range: applPartSSNLCSEBSC 15..255 <DEFAULT> (default value: 250) Contained in the following commands: CREATE OPC, GET OPC, SET OPC This parameter defines the SubsystemNumber for BSSAP-LE (Base Station System Application Part-LCS Extension) for SMLC (Serving Mobile Location Center) point of view. Validity range: applPartSSNLESMLC 15..255 <DEFAULT> (default value: 252) Contained in the following commands: CREATE OPC, GET OPC, SET OPC This attribute will assume two values: FALSE that means 1.5 channel mode and TRUE that means 1 channel mode. The option TRUE allows to use the uplink of the common group call channel by the subsequent talker in cae of Voice Group Call Services(1 channel model for VGCS). Validity range: asciOneChannelModel TRUE FALSE <DEFAULT> (default value:FALSE) Contained in the following commands: GET BSC, SET BSC This parameter is used to indicate whether the advancedSpeechCal- lItemsService is enabled in a cell or not. If the value ASCI_ENABLED is set, both VBS and VGCS services are enabled. Validity range: advancedSpeechCallItemsService ASCI_DISABLED ASCI_ENABLED <DEFAULT> (default value: ASCI_DISABLED) Contained in the following commands: CREATE BTS, GET BTS, SET BTS 1494 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller ASCIULR ASEV ASMONTH This parameter is used to enable or disable the uplink reply procedure for both VGCS and VBS. If the ASCISER is disabled the uplink reply procedure must be disabled; if ASCISER is enabled the uplink reply procedure can be enabled or disabled. Validity range: asciUplinkReply ULRDISABLE VBSENABLE VGCSENABLE VBC_VGCSENABLE <NULL> (default value: ULRDISABLE) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This attribute represents the severity associated to the environmental event. Validity range: associatedSeverity CRITICAL MAJOR MINOR <DEFAULT> (default value: CRITICAL) Contained in the following commands: GET ENVA, CREATE ENVA, SET ENVA This attribute indicates the A-Int Monitor Thresholds for SS7 channels. The threshold is the percentage between out of service SS7L on equipped SS7L; that is: ASMONTH = (SS7L out of service / SS7L equipped)*100). The threshold values can be assigned only when the flag attribute is set to enabled. Validity range: minor disabled 0..0 enabled 1..100 (default value: 30) major disabled 0..0 enabled 1..100 (default value: 60) critical disabled 0..0 enabled 1..100 (default value: 90) Contained in the following commands: GET BSC, SET BSC A30808-X3247-L230-3-7619 1495 Commands Base Station Controller CML:BSC ASSLAPD ASTRING ASUBCH ASUBENCAP ASUBISAT This attribute specifies the SUBTSLB control LAPD. Validity range: associatedLapd It is defined as a pathname. Accepted values are: LPDLM, LPDLMTD. Contained in the following commands: CREATE SUBTSLB, GET SUBTSLB This attribute represents further information related to environmental alarm. Validity range: associatedString 0..26 characters string Contained in the following commands: CREATE ENVA, GET ENVA, SET ENVA The ASUBCH (A-sub Channel) parameter identifies the A-Sub signal channel used for O&M messages. It consists of three fields: pcmsNumber, Tsl (Timeslot) and Ssl (Sub-Slot). Validity range: PcmsNumber 0..35 Tsl 1..31 for PCM30 line 1..24 for PCM24 line Ssl 0..3 (reserved for future implementation) Contained in the following commands: CREATE LPDLS, GET LPDLS This attribute indicates whether the creation of PCMS object in single trunk mode is enabled. Validity range: asubEnhancedCapacityAllowed TRUE, FALSE, <NULL> (default value: FALSE) Contained in the following commands: GET BSC, SET BSC This attribute indicates whether the LAPD link on the Asub interface is satellited or terrestrial. Validity range: asubInterfacelsSatellited FALSE, TRUE 1496 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller ATIME<n> ATTID (default value: FALSE) Contained in the following commands: SET BSC, GET BSC Four parameters are provided (<n> from 1 to 4). This parameter defines the daily time intervals (first, second, etc.) of observation of a SCA object (accumulation periods); we can have up to 4 accumulation periods a day and the accumulation time periods must not have intersections. Each parameter consists of two fields: startTime (startHour and startMinute) and stopTime (stopHour and stopMinute). Validity range: accumulationTime<n> startTime startHour 6..23 (default value: 6) startMinute 0..59 (default value: 0) stopTime stopHour 6..23 (default value: 23) stopMinute 0..59 (default value: 59) For ATIME2 to ATIME4 also the value <NULL> can be selected by the user. Contained in the following commands: CREATE SCA, GET SCA, SET SCA This parameter contains the list of the related FMOs (Functional Managed Object) for a certain HMO(Hardware Managed Object); the related value depends on the working state of the target HMO. If the HMO supports some related functionalities, the value will contain the list of FMOs. If the HMO is not providing service, but there is an available spare HMO that supports the functionalities, the value will be an empty FMOs list. If the HMO is faulty, and no spare HMO is available, the value will maintain list of FMOs it had before the fault (in this way the operator can know the list of the lost functionality). Validity range: attributeIdentifier RELATED_FUNCTIONAL_OBJECTS RELATED_EQUIPMENT_OBJECTS * A30808-X3247-L230-3-7619 1497 Commands Base Station Controller CML:BSC AUTOREP AVPNSME AVPRACHINT (*only for TSLA object) Contained in the following commands: GETRELATIONSHIP CPEX, GETRELATIONSHIP DISK, GETRELATIONSHIP DK40, GETRELATIONSHIP FAN, GETRELATIONSHIP IXLT,GETRELATIONSHIP LICD, GETRELATIONSHIP LICDS, GETRELATIONSHIP MEMT, GETRELATIONSHIP MPCC, GETRELATIONSHIP NTW, GETRELATIONSHIP PPCC, GETRELATIONSHIP PPCU, GETRELATIONSHIP PPLD, GETRELATIONSHIP PPXL, GETRELATIONSHIP PPXP, GETRELATIONSHIP PPXT, GETRELATIONSHIP PPXU, GETRELATIONSHIP PWRD, GETRELATIONSHIP TDPC, GETRELATIONSHIP X25A, GETRELATIONSHIP TSLA, GETRELATIONSHIP X25D. This parameter allows the user to enable or disable the automatic file upload. This operation can be activated for no more than 20 cells. Validity range: autoReport TRUE FALSE <DEFAULT> (default value: FALSE) Contained in the following commands: CREATE RFLOOP, GET RFLOOP, SET RFLOOP This parameter defines the average measurement period of noise power. Validity range: averagePeriodNoiseMeas 0..255 frames <DEFAULT> (default value: 10 frames) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter defines the averaging period for the interference power measurement for the RACH. Validity range: averagePeriodRACHInt avp_RACH1 1..127 (default value: 30) avp_RACH2 1..127 (default value: 30) avp_RACH3 1..127 (default value: 30) Contained in the following commands: GET PWRCTD, SET PWRCTD 1498 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller AVPSDMEAS BAF BAND BANDOFHYS BAUDRATE This parameter defines the averaging period of sync detection measurement. Validity range: averagePeriodSDMeas 0..255 frames <DEFAULT> (default value: 48 frames) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD Defines frame alignment bits, called spare bits a4-a7, that can be set by an operator. This attribute is only significant for PCM30 lines and not for PCM24. Validity range: baf 0..255 <NULL> (default value: 0) Contained in the following commands: CREATE PCMA, GET PCMA, CREATE PCMB, GET PCMB, SET PCMB, CREATE PCMG, GET PCMG, SET PCMG, CREATE PCMS, GET PCMS, SET PCMS This parameter defines the band of frequencies observed by a SCA instance. Validity range: band P E DCS GSM_R PCS GSM850 Contained in the following commands: CREATE SCA, GET SCA This parameter defines the bandwidth of hysteresis. The value of this parameter must be lower than the ALTH parameter value. Validity range: bandWidthOfHysteresis 0..100 dB <DEFAULT> (default value: 25 dB) Contained in the following commands: CREATE RFLOOP, GET RFLOOP, SET RFLOOP It is necessary with clock equal to INTERNAL; when clock is equal to EXTERNAL, this parameter must be skipped. Validity range: baudRate BAUD_4800 BAUD_9600 BAUD_19200 BAUD_38400 A30808-X3247-L230-3-7619 1499 Commands Base Station Controller CML:BSC BCCHFREQ BCCHFREQTD BCCHTRX BCIDLERESTH BAUD_64000 <DEFAULT> (default value: BAUD_64000) Contained in the following commands: CREATE X25D, GET X25D This attribute defines the absolute radio frequency channel number of the BCCH channel. Validity range: bcchFrequency 0..1023 For the values see the complete look-up tables in Appendix B: Group 1. Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE TGTBTS, GET TGTBTS, SET TGTBTS This parameter defines BCCH frequency of TD-SCDMA cell defined by Radio Frequency Number. Validity range: bCCHFrequencyTD 0..67 A conversion table to the physical frequency can be found in Appendix B: Group 9. Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD, CREATE TGTBTSTD, GET TGTBTSTD, SET TGTBTSTD This read-only parameter is equal to TRUE when the TRX is the broadcast one (BCCHTRX), otherwise is equal to FALSE. Validity range: bcchTransceiver TRUE FALSE Contained in the following commands: GET TRX This parameter indicates the threshold for the minimumpercentage of resources that are kept in idle state on the BCCH carrier. Validity range: bcchIdleResThr 0..100 <DEFAULT> (default value: 50) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD 1500 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BCKUPESU BEPAVGP BER BHOFOT This read-only parameter indicates which software ESU (Executable Software Unit) will be loaded at next system restart. Validity range: backupESU pathname Contained in the following commands: GET BTSMOSUSW, GET BTSMTDOSUSW, GET BSCOSUDB, GET BSCOSUSW, GET TRAUOSUSW This parameter is sent on systeminformation message to provide MS with BEP_PERIOD value, in order to filter BEP values as written in GSM 05.08. Validity range: bitErrorProbabilityAveragePeriod 0..15 <NULL> (default value: 5) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF Bit Error Rate. Validity range: ber E10_3 E10_4 E10_5 <DEFAULT> (default value: E10_3) Contained in the following commands: CREATE PCMA, GET PCMA, CREATE PCMB, GET PCMB, SET PCMB, CREATE PCMG, GET PCMG, SET PCMG, CREATE PCMS, GET PCMS, SET PCMS This parameter represents the timer used to establish the time for which a back handover due to traffic reason or PBGT (Power Budget) has to be avoided. Validity range: backHoForbiddenTimer 1..120 s <NULL> (default value: 100) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC A30808-X3247-L230-3-7619 1501 Commands Base Station Controller CML:BSC BLERAVEDL BLERAVEUL BMONTH This parameter allows to define the averaging period (TAVG) for BLER calculation for a Downlink TBF. The value is expressed in unit of 20 ms. The averaging period depends also on the number of radio timeslots (#TS) allocated to a radio timeslots, according to the formula: TAVG = BLERAVEDL / #TS. Validity range: blockErrorRateAveragingPeriodDownlink UNIT025 UNIT050 UNIT075 UNIT100 UNIT150 UNIT200 UNIT250 UNIT300 UNIT350 UNIT400 <DEFAULT> (default value: UNIT400) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter allows to define the averaging period (TAVG) for BLER calculation for an Uplink TBF. The value is expressed in unit of 20 ms. The averaging period depends also on the number of radio timeslots (#TS) allocated to a radio timeslots, according to the formula: TAVG = BLERAVEUL / #TS. Validity range: blockErrorRateAveragingPeriodUplink UNIT025 UNIT050 UNIT075 UNIT100 UNIT150 UNIT200 UNIT250 UNIT300 UNIT350 UNIT400 <DEFAULT> (default value: UNIT400) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute indicates the B-Int Monitor Thresholds for traffic channels. It represents the percentage of out of service channels on equipped traffic channels. The threshold values can be assigned only when the previous attribute is enabled. Validity range: minor disabled 0..0 enabled 1..100 (default value: 30) major disabled 0..0 enabled 1..100 (default value: 60) critical disabled 0..0 1502 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BNDWIDTDD BPAGCHR BPRACHR enabled 1..100 (default value: 90) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This attribute defines the bandwidth of the TDD cell. Validity range: bandwidthTdd MCPS384 MCPS128 Contained in the following commands: CREATE TGTTDD, GET TGTTDD, SET TGTTDD This parameter indicates the number of blocks reserved for PAGCH, PDTCH and PACCH for the 52 frames multiframe case (see GSM 05.02). The parameter is coded according to the following table: 0 0 0 0 0 blocks reserved for PAGCH, PDTCH and PACCH; 0 0 0 1 1 blocks reserved for PAGCH, PDTCH and PACCH;
1 1 0 0 12 blocks reserved for PAGCH, PDTCH and PACCH. This parameter also determines the number of mobile stations allocable on PBCCH and PCCCH channels for packet data traffic both for uplink and downlink directions (it will be computed in a proportional way based on the number of free blocks in the control channel). Validity range: bsPagchBlocksReserved 0..12 <DEFAULT> (default value: 7) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter indicates the number of blocks reserved in a fixed way to the PRACH channel on any PDCH carrying PCCCH and PBCCH (Only for 52 type PCCCH) (see GSM05.02). The parameter is coded according to the following table: 0 0 0 0 No blocks reserved for PRACH 0 0 0 1 Block B0 reserved for PRACH 0 0 1 0 Blocks B0, B6 reserved for PRACH 0 0 1 1 Blocks B0, B6, B3 reserved for PRACH 0 1 0 0 Blocks B0, B6, B3, B9 reserved for PRACH 0 1 0 1 Blocks B0, B6, B3, B9, B1 reserved for PRACH 0 1 1 0 Blocks B0, B6, B3, B9, B1, B7 reserved for PRACH 0 1 1 1 Blocks B0, B6, B3, B9, B1, B7, B4 reserved for PRACH A30808-X3247-L230-3-7619 1503 Commands Base Station Controller CML:BSC BSCDVMA BSCDVMATD BSCOVLH 1 0 0 0 Blocks B0, B6, B3, B9, B1, B7, B4, B10 reserved for PRACH 1 0 0 1 Blocks B0, B6, B3, B9, B1, B7, B4, B10, B2 reserved for PRACH 1 0 1 0 Blocks B0, B6, B3, B9, B1, B7, B4, B10, B2, B8 reserved for PRACH 1 0 1 1 Blocks B0, B6, B3, B9, B1, B7, B4, B10, B2, B8, B5 reserved for PRACH 1 1 0 0 Blocks B0, B6, B3, B9, B1, B7, B4, B10, B2, B8, B5, B11 reserved for PRACH This parameter also determines the number of mobile stations allocable on PBCCH and PCCCH channels for packet data traffic both for uplink and downlink directions (it will be computed in a proportional way based on the number of free blocks in the control channel). Validity range: bsPrachBlocksReserved 0..12 <DEFAULT> (default value: 4) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter represents the value of timer T3198, at MS side, expressed in number of RLC blocks. Validity range: bsCountdownValueMax 1..15 <DEFAULT> (default value: 15) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter represents the value of timer T3198, at MS side, expressed in number of RLC blocks. Validity range: bsCountdownValueMaxTD 1..15 <DEFAULT> (default value: 5) Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD This attribute allows a managing systemto enable or disable the BSC Overload Handling. Validity range: bscOvlHand FALSE TRUE (default value: TRUE) Contained in the following commands: GET BSC, SET BSC 1504 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BSCT1 BSCT3 BSCT3121 BSCT4 Time to receive BLOCKING ACK message. Validity range: TunitType HLFSEC (half second unit), SEC5 (5-second unit), (default value: HLFSEC) TvalueType 0-254 (default value: 12) Contained in the following commands: GET BSC, SET BSC RESOURCE INDICATION message sending periodicity. Validity range: TunitType HLFSEC (half second unit), SEC5 (5-second unit), (default value: HLFSEC) TvalueType 0-254 (default value: 50) Contained in the following commands: GET BSC, SET BSC This timer is started by the sending of an INTER SYSTEM TO UTRAN HANDOVER message and is normally stopped when the message HO COMPLETE is received. Validity range: TunitType HLFSEC (half second unit), SEC5 (5-second unit), (default value: HLFSEC) TvalueType 0-254 (default value: 10) Contained in the following commands: GET BSC, SET BSC Time to return RESET ACK message. Validity range: TunitType HLFSEC (half second unit), SEC5 (5-second unit), (default value: HLFSEC) TvalueType 0-254 (default value: 60) Contained in the following commands: GET BSC, SET BSC A30808-X3247-L230-3-7619 1505 Commands Base Station Controller CML:BSC BSCT7 BSCT8 BSCT10 BSCT11 HANDOVER REQUIRED message sending periodicity. Validity range: TunitType HLFSEC (half second unit), SEC5 (5-second unit), (default value: HLFSEC) TvalueType 0-254 (default value: 4) Contained in the following commands: GET BSC, SET BSC Time to receive HANDOVER COMPLETE message. Validity range: TunitType HLFSEC (half second unit), SEC5 (5-second unit), (default value: HLFSEC) TvalueType 0-254 (default value: 10) Contained in the following commands: GET BSC, SET BSC Time to receive ASSIGNMENT COMPLETE message to MS. Validity range: TunitType HLFSEC (half second unit), SEC5 (5-second unit), (default value: HLFSEC) TvalueType 0-254 (default value: 10) Contained in the following commands: GET BSC, SET BSC Maximum allowed queuing time. Validity range: TunitType HLFSEC (half second unit), SEC5 (5-second unit), (default value: HLFSEC) TvalueType 0-254 (default value: 16) Contained in the following commands: GET BSC, SET BSC 1506 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BSCT13 BSCT17 BSCT18 BSCT19 Reset Guard period at BSS. Validity range: TunitType HLFSEC (half second unit), SEC5 (5-second unit), (default value: HLFSEC) TvalueType 0-254 (default value: 50) Contained in the following commands: GET BSC, SET BSC Overload timer. Validity range: TunitType HLFSEC (half second unit), SEC5 (5-second unit), (default value: HLFSEC) TvalueType 0-254 (default value: 20) Contained in the following commands: GET BSC, SET BSC Overload timer. Validity range: TunitType HLFSEC (half second unit), SEC5 (5-second unit), (default value: HLFSEC) TvalueType 0-254 (default value: 60) Contained in the following commands: GET BSC, SET BSC Time to receive RESET CIRCUIT ACKNOWLEDGE at the BSS. Validity range: TunitType HLFSEC (half second unit), SEC5 (5-second unit), (default value: HLFSEC) TvalueType 0-254 (default value: 12) Contained in the following commands: GET BSC, SET BSC A30808-X3247-L230-3-7619 1507 Commands Base Station Controller CML:BSC BSCT20 BSCTQHO BSCTYP BSIC Time to receive CIRCUIT GROUP BLOCKING ACKNOWLEDGE. Validity range: TunitType HLFSEC (half second unit), SEC5 (5-second unit), (default value: HLFSEC) TvalueType 0-254 (default value: 12) Contained in the following commands: GET BSC, SET BSC Maximum allowed queuing time for handover. Validity range: TunitType HLFSEC (half second unit), SEC5 (5-second unit), (default value: HLFSEC) TvalueType 0-254 (default value: 20) Contained in the following commands: GET BSC, SET BSC This read-only parameter defines Validity range: bscType SINGLECELL MULTICELL Contained in the following commands: GET BSC This parameter represents the Base Station Identity Code and it consists of two fields: NCC (Network Colour Code) and BCC (BS Colour Code). Validity range: bsIdentityCode Ncc 0..7 Bcc 0..7 Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE TGTBTS, GET TGTBTS, SET TGTBTS 1508 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BSIDC BSMONTH BSPBBLK This parameter defines the Base Station Identity Code of TS-SCDMA BTSC consisting of BCC (Base Station Colour Code, 5 bit) = Code Group and NCC (Network Colour Code 2 bit) = Basic Midamble Number. Validity range: bsIdentityCodeTD valued TRUE, FALSE (default value: FALSE) NCC 0..3 BCC 0..31 Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD, CREATE TGTBTSTD, GET TGTBTSTD, SET TGTBTSTD. This attribute indicates the B-Int Monitor Thresholds for signalling channels. It represents the percentage of out of service signalling channels on equipped signalling channels. The threshold values can be assigned only when the previous attribute is enabled. Validity range: minor disabled 0..0 enabled 1..100 (default value: 30) major disabled 0..0 enabled 1..100 (default value: 60) critical disabled 0..0 enabled 1..100 (default value: 90) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This attribute indicates the number of blocks allocated to the PBCCH in the multiframe. The parameter is coded according to the following table: 0 0 Block B0 used for PBCCH; 0 1 Block B0, B6 used for PBCCH; 1 0 Block B0, B6, B3 used for PBCCH; 1 1 Block B0, B6, B3, B9 used for PBCCH. This parameter also determines the number of mobile stations allocable on PBCCH and PCCCH channels for packet data traffic both for uplink and downlink directions (it will be computed in a proportional way based on the number of free blocks in the control channel). Validity range: A30808-X3247-L230-3-7619 1509 Commands Base Station Controller CML:BSC BSSAPSSN BTSEFAM BTSHSCSD BTSOVLH bsPbcchBlocks 0..3 <DEFAULT> (default value: 1) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute indicates the Subsystem Number in the SCCP. Validity range: bssapSsn 15..255 <DEFAULT> (default value: 254) Contained in the following commands: CREATE OPC, GET OPC This read-only parameter defines the family of the BTSE equipment. Validity range: btseFamily BTSE BTSEP BTSEPICO BTSEEM BTSEC BTSEXS Contained in the following commands: GET BTSM, GET BTSMTD This attribute indicates whether HSCSDservice is activated in the cell or not. Validity range: btsHSCSD FALSE TRUE <DEFAULT> (default value: FALSE) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD. This attribute allows a managing systemto enable or disable the BTS Overload Handling by BSC. Validity range: btsOvlHand FALSE TRUE (default value: TRUE) Contained in the following commands: GET BSC, SET BSC 1510 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller BTSPO BVCBHIPER BVCBLPER BVCBMAPER This attribute defines the geographical position of the BTSMTD. Validity range: bTSPosition signOfLatitude north, south, notUsed latitue 0..90 signOfLongitude east, west, notUsed longitude 0..180 (default value: signOfLatitude notUsed latitue 0 signOfLongitude notUsed longitude 0) Contained in the following commands: CREATE BTSMTD, GET BTSMTD, SET BTSMTD If BVC Bucket Level is greater than BVCBHIPER * Bucket Size PCU then Bucket Congestion is started. Validity range: bvcBucketHighPercentage PER50 PER60 PER70 PER80 PER90 <DEFAULT> (default value: PER70) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF If BVC Bucket Level is lower than BVCBLPER * Bucket Size PCU then Bucket Congestion is finished. Validity range: bvcBucketLowPercentage PER10 PER20 PER30 PER40 PER50 PER60 PER70 PER80 <DEFAULT> (default value: PER60) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute reduces the value of Bmax automatically computed by BSC. BSC criterion is: (C + 1 sec.) * Rmax, where C is the timer reported in GSM 08.18 recommendation and Rmax is the maximum rate assigned to BVC. Validity range: bvcBucketMaxPercentage PER010 PER020 A30808-X3247-L230-3-7619 1511 Commands Base Station Controller CML:BSC BVCBSPPER C31H C32QUAL PER030 PER040 PER050 PER060 PER070 PER080 PER090 PER100 PER110 PER120 PER130 PER140 PER150 PER160 PER170 PER180 PER190 PER200 <DEFAULT> (default value: PER100) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute assigns the value of Bucket Size PCU as percentage of Bmax (twice and so on). Validity range: bvcBucketSizePcuPercentage PER100 PER110 PER120 PER130 PER140 PER150 PER160 PER170 PER180 PER190 PER200 <DEFAULT> (default value: PER200) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute indicates if the GPRS reselection hysteresis shall be applied to the C31 criterion. Validity range: c31Hysteresis TRUE FALSE <DEFAULT> (default value: TRUE) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF If C32_QUAL is set, positive GPRS_RESELECT_OFFSET values shall only be applied to the neighbor cell with the highest RLA value among those cells for which C32 is compared. Validity range: c32Qualifier TRUE FALSE <DEFAULT> 1512 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller CACKTYP CALLF<nn> CALLF<nn>TD (default value: FALSE) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter indicates the format of the Packet Control Acknowledgement the MS shall transmit when polled. The meaning of the setting values is the following: 0 Packet Control Acknowledgement format is four access bursts 1 Packet Control Acknowledgement format is RLC/MAC control block The value 0 (default value) is hardcoded in the software, so parameter changes have no influence. Validity range: controlAcknowledgementType 0..1 <DEFAULT> (default value: 0) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF Sixty three parameters are provided (<nn> from 01 to 63). This parameter (cell allocation) defines the set, without the Bcch Frequency, of radio frequencies allocated and available to a cell. If this attribute is used in SET command in order to delete all the frequencies, it must be set only to the BCCH frequency value, skip- ping all the other entries. Validity range: cellAllocationF<nn> 0..1023 <NULL> (where <nn>= 01..63) Contained in the following commands: CREATE BTS, GET BTS, SET BTS Two parameters are provided (<nn> 01 and 02). This parameter (cell allocation) defines the set, without the Bcch Frequency, of radio frequencies allocated and available to a TD- SCDMA cell. Validity range: cellAllocationF<nn> 0..67 <DEFAULT> <NULL> (where <nn>= 01..02) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD A30808-X3247-L230-3-7619 1513 Commands Base Station Controller CML:BSC CARRTOIDRACHI CBCLTYPE CBCPH CBQ This parameter defines the C/I target for RACH. The step size is 0.5 dB. Validity range: carrToIntDesRACHI C/I_RACH1 -10.0..53.5 (step 0.5 dB) <DEFAULT> (default value:40) Contained in the following commands: GET PWRCTD, SET PWRCTD This read-only parameter indicates the type of CBC used. Validity range: cbclType CBC_EXTERNAL CBC_INTERNAL (default value:CBC_EXTERNAL) Contained in the following commands: GET CBCL This parameter defines the type of Cell Broadcast Center connected to the BSC. The meaning of the setting values is the following: PH1_CBC the CBC connected to the BSC is a phase 1 PH2_CBC the CBC connected to the BSC is a phase 2 To indicate that the CBC connected to the BSC does not support the extended CBCH, the operator has to set CBCPH=PH1_CBC, otherwise CBCPH=PH2_CBC (the CBC connected to the BSC support the extended CBCH). Validity range: CBCphase PH1_CBC PH2_CBC (default value: PH1_CBC) Contained in the following commands: GET BSC, SET BSC This attribute is used by the network to control mobile station GSM Phase 2 cell selection and reselection. The meaning of the setting values is the following: 0 high priority 1 low priority Validity range: cellBarQualify 0..1 <NULL> (default value: 0) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD. 1514 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller CCDIST CCELL1 CCELL2 CELLBARR The attribute enables/disables whether the distance should also have an impact on the intracell handover decision in addition to the HORXLVDLI/HORXLVDLO within the concentric cell intracell handover algorithm. The distance criteria is NOT applicable for mixed (Dual Band) cells. Validity range: enableConCellDist FALSE TRUE (default value: FALSE) Contained in the following commands: GET HAND, SET HAND The attribute defines the cell belonging to the sectorized concentric cells for which it is possible the intercell handover from inner to inner area. The attribute is meaningless if one cell, serving or target, is not concentric. Validity range: collocatedCell1 Pathname <NULL> (example OBJ1:2/OBJ2:1/OBJ3:5) Contained in the following commands: GET HAND, SET HAND The attribute defines the cell belonging to the sectorized concentric cells for which it is possible the intercell handover from inner to inner area.The attribute is meaningless if one cell, serving or target, is not concentric. Validity range: collocatedCell2 Pathname <NULL> (example OBJ1:2/OBJ2:1/OBJ3:5) Contained in the following commands: GET HAND, SET HAND This attribute indicates whether Mobile Station may camp on the cell. The value "TRUE" indicates that the cell is barred and camping on the cell is forbidden. Validity range: cellBarred FALSE TRUE <DEFAULT> (default value: FALSE) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD A30808-X3247-L230-3-7619 1515 Commands Base Station Controller CML:BSC CELLGLID CELLRESH CELLTYP Cell Global Identity. This attribute contains the Cell Identification (CI) and the Location Area Id of the cell. A Location Area Id is unique within a GSMPLMN; a Cell Identification is unique within a location area. It consists of four fields: MCC Mobile Country Code MNC Mobile Network Code LAC Location Area Code Cl Cell Identity Validity range: MCC string of 3 chars (the three characters are mandatory) MNC string 1..3 chars (at least the first character is set) LAC 0..65535 CI 0..65535 Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE TGTBTS, GET TGTBTS, SET TGTBTS, CREATE TGTBTSTD, GET TGTBTSTD, SET TGTBTSTD CREATE TGTFDD, GET TGTFDD, SET TGTFDD, CREATETGTTDD, GET TGTTDD, SET TGTTDD, CREATEBTSTD, GET BTSTD, SET BTSTD The cellReselectHysteresis attribute indicates the value of the received RF power level hysteresis required for cell reselection. This parameter range is from0 to 14 dB at steps of 2 dB and is coded as an integer number in the range 0 to 7. Validity range: cellReselectHysteresis 0..7 (2 dB step size) <DEFAULT> (default value: 2) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD. It specifies the type of the cell. Validity range: cellType STDCELL ("standard" cell - maximum MS distance: 35 km), EXTCELL ("extended" cell - maximum MS distance:100 km) Contained in the following commands: CREATE BTS, GET BTS, SET BTS 1516 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller CFS CHTYPE This attribute identifies the maximum size (in Mbytes) for each CTR log file. Validity range: ctrFileSize 1..6 (default value:1) Contained in the following commands: GET BSC, SET BSC This attribute defines the logical channel combination mapped onto the physical channel (timeslot). The following are the permitted ways by which the channels can be combined onto basic physical channels (numbers appearing in brackets after channel designations indicate sub-channel numbers; channels and sub-channels need not to be necessarily assigned). Validity range: channelCombination TCHFULL: TCH/F + FACCH/F + SACCH/TF SDCCH: SDCCH/8 + SACCH/C8 MAINBCCH: FCCH + SCH + BCCH + CCCH MBCCHC:FCCH + SCH + BCCH + CCCH +SDCCH/4 (0..3) + SACCH/C4 (0..3) CCCH: BCCH + CCCH SCBCH: SDCCH/8(0..7) + SACCH/C8(0..7) + CBCH BCBCH: FCCH + SCH + BCCH + CCCH + SDCCH/4 + SACCH/4 + CBCH TCHF_HLF: TCH/H(0,1) + FACCH/H(0,1) + SACCH/TH(0,1) or TCH/F + FACCH/F + SACCH/TF TCHSD: SDCCH/8 + SACCH/8 + TCH/H(0,1) + FACCH/H(0,1) + SACCH/TH(0,1) or TCH/F + FACCH/F + SACCH/F * The CBCH channel is the subslot number 2 (D2) of both SDCCH/8 and SDCCH/4. where: TCH Traffic Channel FACCH Fast Associated Control Channel /H Half Rate /F Full Rate SACCH Slow Associated Control Channel SDCCH Standalone Dedicated Control Channel FCCH Frequency Correction Channel SCH Synchronization Channel BCCH Broadcast Control Channel CCCH Common Control Channel (CCCH = PCH + RACH + AGCH) PCH Paging Channel RACH Random Access Channel AGCH Access Grant Channel A30808-X3247-L230-3-7619 1517 Commands Base Station Controller CML:BSC CHPOOLTYP CICFM CID CITASUP CBCH Cell Broadcast Channel TCHSD Combined Channel are all the logical channel types which can be mapped onto physical time slot. Contained in the following commands: CREATE CHAN, GET CHAN This parameter defines the pool type. Validity range: channelPoolType TCHSDPOOL TCHPOOL SDCCHPOOL <NULL> Contained in the following commands: CREATE CHAN, GET CHAN, SET CHAN This attribute specifies the format for the Circuit Identity Code. Validity range: cicFormat NOTSTRUCT GSM (default value: GSM) Contained in the following commands: GET BSC, SET BSC This attribute identifies the cell which a trace shall be started in. It consists of a sequence of two fields: the first field represents the btsm number, the second field represents the bts relative number. Validity range: celIIdentity Pathname (example OBJ1:2/OBJ2:1) Contained in the following commands: CREATE CTRSCHED, GET CTRSCHED, SET CTRSCHED, UPLCELLTR CTRCO This parameter allows to enable/disable the location service for mobiles in idle mode (e.g. emergency call). When this parameter is TRUE the complete Layer 3 Information contains the APDU IE with inside the new BBSLAP TA Layer3 message. Validity range: celIIdTimeAdvSupport TRUE FALSE <DEFAULT> (default value: FALSE) Contained in the following commands: GET BSC, SET BSC 1518 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller CLEAR CLOCK CNTLTHTXPUL CNTTH CNTTHPYUL This attribute overrides output file or appends to it. Validity range: clear YES, NO Contained in the following commands: SET It indicates if the used clock is internal to the IXLT card or coming from somewhere else. Validity range: clock INTERNAL EXTERNAL <DEFAULT> (default value: EXTERNAL) Contained in the following commands: CREATE X25D, GET X25D This parameter defines the threshold of some counters. There is a counter used for each logical user in each uplink timeslot. If the transmit power used for a logical user at uplink is too low, the relative counter is increased by one. If the value of counter is over this threshold, FC generates an alert. Validity range: cntLowerThresTxPwrUL 1..48 <DEFAULT> (default value: 24) Contained in the following commands: GET PWRCTD, SET PWRCTD This parameter, only for detection SYNC1 signature, defines a threshold for the number of points which value fulfill the PeakSideDiffThreshold. Validity range: countThreshold 1..15 <DEFAULT> (default value: 8) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter defines the threshold of some counters. There is a counter in each uplink timeslot to record party effect; if party effect occurs, the relative counter will be increased by one. If the value of counter is over this threshold, FC generates an alert. Validity range: cntThresPartyUL 1..48 <DEFAULT> A30808-X3247-L230-3-7619 1519 Commands Base Station Controller CML:BSC CNTUTHTXPDL CNTUTHTXPUL CODE CONCELL (default value: 16) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter defines the threshold of some counters. There is a counter used for each logical user in each downlink timeslot. If the transmit power used for a logical user at downlink is too high, the rela- tive counter is increased by one. If the value of counter is over this threshold, FC generates an alert. Validity range: cntUpperThresTxPwrDL 1..48 <DEFAULT> (default value: 16) Contained in the following commands: GET PWRCTD, SET PWRCTD This parameter defines the threshold of some counters. There is a counter used for each logical user in each uplink timeslot. If the transmit power used for a logical user at uplink is too high, the relative counter is increased by one. If the value of counter is over this threshold, FC generates an alert. Validity range: cntUpperThresTxPwrUL 1..48 <DEFAULT> (default value: 16) Contained in the following commands: GET PWRCTD, SET PWRCTD This field selects the line code to be provided on the line. Note: for a PCM24 line the attribute value is meaningless because the B8ZS line code is used. Validity range: code HDB3 AMI <NULL> (default value: HDB3) Contained in the following commands: CREATE PCMA, GET PCMA, CREATE PCMB, GET PCMB, SET PCMB, CREATE PCMG, GET PCMG, SET PCMG, CREATE PCMS, GET PCMS, SET PCMS This attribute is a flag defining if the cell is concentric (TRUE) or not (FALSE). Validity range: concentricCell FALSE TRUE <DEFAULT> 1520 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller CONGTH CPOLICY CPPFAC CRC (default value: FALSE) Contained in the following commands: CREATE BTS, GET BTS, SET BTS The congestion control threshold determines the percentage of transmit buffers used, at which layer 2 requests load reduction measures fromlayer3 or subsequently discards messages (not appli- cable). Validity range: congThreshold 0..6 <DEFAULT> (default value: 0) Contained in the following commands: CREATE OPC, GET OPC, SET OPC This attribute specifies the BSC channel allocation policy when different services are required. Validity range: callPolicy DATA_CALL_ON_BCCH SPEECH_CALL_ON_BCCH NO_PREFERENCE <DEFAULT> (default value: NO_PREFERENCE) Contained in the following commands: SET BSC, GET BSC This parameterdefines the configuration priority (normalised to the maximum one retrieved in the cell) below which the Carrier Parti- tioning Criterion is by-passed by Channel Selection algorithm. Validity range: CarrierPartitioningByPass- Factor 0.00..1.00 (step 0.01) <DEFAULT> (default value: 0.00) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD By selecting the TRUE option, the CRC-4 signal handling for a PCM30 line, or the CRC-6 signal handling for a PCM24 line is enabled on the 2 Mbits/s signal. Validity range: crc FALSE TRUE <DEFAULT> A30808-X3247-L230-3-7619 1521 Commands Base Station Controller CML:BSC CREALL CRESELTRHSOUT CRESELTHRINP CRESOFF (default value: FALSE) Contained in the following commands: CREATE PCMA, GET PCMA, CREATE PCMB, GET PCMB, SET PCMB, CREATE PCMG, GET PCMG, SET PCMG, CREATE PCMS, GET PCMS, SET PCMS This attribute indicates whether call re-establishment is allowed in the cell. Validity range: callReestablishment Allowed ALLOWED NOTALLOWED <DEFAULT> (default value: NOTALLOWED) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD This parameter defines the percentage of occupation threshold : when the number of active gprs mobile is over this value , the network controlled cell reselection procedure can order gprs mobiles to rese- lect another cell until number of gprs active mobile is again under the threshold. Validity range: cellReselectionThreshold- Output 50,100 (step 1) <DEFAULT> (default value: 85) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter defines the congestion threshold above which a gprs mobile is not let to enter this adjacent cell. Validity range: cellReselectionThreshold- Input 0,,85 (step 1) <DEFAULT> (default value: 75) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute applies an offset to the C2 reselection criterion. Validity range: cellReselectionOffset 0..63 (2 dB step size) 1522 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller CRESPARI CSCH3CSCH4SUP CSYNCHS DANGEROUS <NULL> (default value: 1 [2 dB]) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD. This attribute indicates the presence of C2 cell reselection parameters; the 1 value means parameters present. Validity range: cellReselectionParamInd 0..1 <DEFAULT> (default value: 1) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter enables/disables the feature CS3/CS4. In case of BSC object it enables/disables the feature at BSC level. In case of PTPPKF object it enables/disables the feature at PTPPKF level. Validity range: codingScheme3CodingScheme4Support TRUE, FALSE <DEFAULT> (default value: FALSE) Contained in the following commands: GET BSC, SET BSC, CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter indicates if the neighbour TD-SCDMA cell is synchronised or not with the current TD -SCDMA cell. Validity range: cellSynchStatus SYNCHRONIZED NOT_SYNCHRONIZED <NULL> (default value: SYNCHRONIZED) Contained in the following commands: CREATE ADJCTD, GET ADJCTD, SET ADJCTD This attribute specifies whether the execution of the command has to be confirmed by the user. Validity range: dangerous YES - the command has to be confirmed by the user NO - the command hasn't to be confirmed by the user Contained in the following commands: EXEC A30808-X3247-L230-3-7619 1523 Commands Base Station Controller CML:BSC DBVER DEFPOOLTYP DEFPRI This read-only parameter defines the database version; it consists of the two parts: the dbStringId (24 characters) and the dbDate (4 characters). Validity range: dbVersion 28 characters string Contained in the following commands: GET BSCESUDB, GET RSUDB This attribute defines the type of the pool assigned to every TSLA of the given PCMA. For pool type meaning see Appendix B: Tab. 6.14. Validity range: defPoolType POOL_NOTDEF POOL_01 POOL_02 POOL_03 POOL_04 POOL_05 POOL_06 POOL_07 POOL_08 POOL_09 POOL_10 POOL_11 POOL_12 POOL_13 POOL_15 POOL_16 POOL_17 POOL_18 POOL_19 POOL_20 POOL_21 POOL_22 POOL_23 POOL_24 POOL_25 POOL_26 POOL_27 POOL_28 POOL_29 POOL_30 POOL_31 POOL_32 POOL_33 POOL_34 POOL_35 POOL_42 POOL_43 POOL_44 POOL_45 POOL_46 POOL_47 POOL_48 <DEFAULT> (default value: POOL_NOTDEF) Contained in the following commands: CREATE PCMA, GET PCMA This parameter defines the timeslot priority when DCA (Dynamic Channel Allocation) is disabled and PrefPriorities (PREFPRIO parameter) is set to default. Validity range: defaultPriority 0..100 1524 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DELOPT DESTDIR DESTPATHNAME DGRSTRGY (default value: 100) Contained in the following commands: CREATE AIRTSTD, GET AIRTSTD, SET AIRTSTD This flag, if TRUE, selects that the input files must be deleted after a successful compression. Validity range: deleteOption TRUE FALSE Contained in the following commands: FILECOM FILEHANDLER This field specifies the directory name of BSC or LMT disk which the file should be transferred to, copied to or moved to. The user can use the Browse Dir button to select the directory on the LMT hard-disk; for the REMINV object commands the button is not available. Validity range: destinationDir 1..80 characters string Contained in the following commands: UPLALLCELLTR CTRCO, UPLCELLTR CTRCO, UPLCIDF REMINV, UPLLIDF REMINV, UPLFILE, UPLBTSLOG, UPLBTSTDLOG, UPLDFILE RSUDB, UPLMEAS SCANCO, DNLFILE, UPLALLIMSITR TRACE, UPLIMSITR TRACE, UPLOADREQ SCA, UPLOADREQ RFLOOP, UPLPRLOG FILEHANDLER This parameter defines the name of the destination path. Validity range: destinationPathName 1..59 characters string Contained in the following commands: COPY FILEHANDLER, MOVE FILEHANDLER This parameter allows the user to define the resource reallocation procedure by selecting the preferred channel for the allocation. Validity range: downgradeStrategy HSCSD_FIRST_DOWNGRADE GPRS_FIRST_DOWNGRADE DOWNGRADE_HSCSD_ONLY DOWNGRADE_GPRS_ONLY NO_DOWNGRADE <DEFAULT> A30808-X3247-L230-3-7619 1525 Commands Base Station Controller CML:BSC DIRNAME DIRTCHASS DLBFTH (default value: NO_DOWNGRADE) Contained in the following commands: GET BSC, SET BSC This parameter defines the directory name on the BSC disk. Validity range: directoryName 1..59 characters string Contained in the following commands: CREATEDIR FILEHANDLER, DIR FILEHANDLER, REMOVEDIR FILEHANDLER This attribute specifies whether the direct assignment of TCHchannel is enabled or disabled. The meaning of the setting values is the following: FALSE Direct TCH assignment disabled SDCCHMS Direct TCH assignment enabled but disabled for "answer to paging-any channel" cause of CHANNEL REQUIRED message (since SDCCHonly MS may be supported by the network) NOSDCCHMS Direct TCHassignment enabled also for "answer to paging-any channel" cause of CHANNEL REQUIRED message (since SDCCHonly MS is not supported by the network) Validity range: directTchAssignment FALSE SDCCHMS NOSDCCHMS <DEFAULT> (default value: FALSE) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter defines the threshold used for variation of downlink beamforming (DLBF). The attribute has no unit and its step size is 1/16. Validity range: dLBFThreshold N_<nn>_16 <nn>= 01 to 16 <DEFAULT> (default value: N_04_16) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD. 1526 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DLDCAST DLSIRACST DONDLPCTH DONULPCTH This parameter defines if the Priority based Admission Control infor- mation for all DL timeslots is sent by the BTSC within the message RF_TS_PRIORITY_UPDATE_IND to the BSC. Validity range: downlinkDCAStatus TRUE FALSE <DEFAULT> (default value: TRUE) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter specifies if the SIR based Admission Control information for all DL timeslots is sent to the BSC. In case of an Immediate Assignment Procedure the information is included in the Channel Required message; in case of an Assignment Procedure the information is included in the Physical Context Confirm message and in case of an Intracell Handover the information is included in the Intracell Handover Condition Indication message. Validity range: downlinkSIRACStatus TRUE FALSE <DEFAULT> (default value: TRUE) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD. This parameter defines the DO NOTHING threshold for downlink power control (DLPC). The attribute has no unit and its step size is 1/16. Validity range: doNothingDLPCThreshold N_<nn>_16 <nn>= 01 to 16 <DEFAULT> (default value: N_08_16) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD. This parameter defines the DO NOTHING threshold for uplink power control (ULPC). The attribute has no unit and its step size is 1/16. Validity range: doNothingULPCThreshold N_<nn>_16 <nn>= 01 to 16 (default value: N_08_16) <DEFAULT> Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD. A30808-X3247-L230-3-7619 1527 Commands Base Station Controller CML:BSC DONULSCTH DISKCOPY DISTHO DLAPDOVL DNLALLEXE This parameter defines the DO NOTHING threshold for uplink synchronisation control (ULSC). The attribute has no unit and its step size is 1/16. Validity range: doNothingULSCThresold N_<nn>_16 <nn>= 01 to 16 <DEFAULT> (default value: N_08_16) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD. This attribute defines whether to format both copies or only one. Validity range: diskCopy BOTH_DISK SELECTED Contained in the following commands: FORMAT DISK This attribute indicates whether handover due to distance between Mobile Station and BTS is enabled or disabled. Validity range: enableDistanceHo FALSE TRUE (default value: TRUE) Contained in the following commands: GET HAND, SET HAND, GET HANDTD, SET HANDTD This parameter allows to enable or disable the procedure that detects the Download Overload. Validity range: downlinkLapdOverload TRUE FALSE (default value: TRUE) Contained in the following commands: GET BSC, SET BSC This parameter allows to enable or disable the download of all executable files. Validity range: DnlAllExe YES NO Contained in the following commands: CREATE RSUSWLH 1528 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DPBGTHO DRXTMA DRXTMATD This parameter indicates whether the speed sensitive handover decision algorithm is enabled or not. Validity range: enableDelayPowerBudgetHo FALSE, TRUE (default value: FALSE) Contained in the following commands: GET HAND, SET HAND This parameter indicates the maximum value allowed for the mobile station to request for Non-DRX mode after packet transfer mode (upper limit for the mobile station timer T3194). 0 0 0 No Non-DRX mode after packet transfer mode 0 0 1 Max. 1 sec. Non-DRX mode after packet transfer mode 0 1 0 Max. 2 sec. 0 1 1 Max. 4 sec. 1 0 0 Max. 8 sec. 1 0 1 Max. 16 sec. 1 1 0 Max. 32 sec. 1 1 1 Max. 64 sec. Validity range: discontinousReceptionTimerMax 0..7 <DEFAULT> (default value: 7) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter indicates the maximum value allowed for the UE to request for Non-DRX mode after packet transfer mode (upper limit for the mobile station timer T3194). 0 0 0 No Non-DRX mode after packet transfer mode 0 0 1 Max. 1 sec. Non-DRX mode after packet transfer mode 0 1 0 Max. 2 sec. 0 1 1 Max. 4 sec. 1 0 0 Max. 8 sec. 1 0 1 Max. 16 sec. 1 1 0 Max. 32 sec. 1 1 1 Max. 64 sec. Validity range: discontinousReceptionTimerMaxTD 0..7 <DEFAULT> A30808-X3247-L230-3-7619 1529 Commands Base Station Controller CML:BSC DTEDCE DTXDLFR DTXDLHR DTXUL (default value: 7) Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD It indicates if IXLT works as Data Terminal Equipment or as Data Communication Equipment. Validity range: dteDce DTE DCE <DEFAULT> (default value: DTE) Contained in the following commands: CREATE X25D, GET X25D The dTxDownLinkFullRate is used to indicate whether this service is enabled or not. Validity range: dTxDownLinkFullRate FALSE TRUE <DEFAULT> (default value: FALSE) Contained in the following commands: CREATE BTS, GET BTS, SET BTS The dTxDownLinkHalfRate is used to indicate whether this service is enabled or not. Validity range: dTxDownLinkHalfRate FALSE TRUE <NULL> (default value: FALSE) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This dTxUpLink is used to indicate whether this service is enabled or not. Validity range: dtxUpLink MAYFSHNH(MS may use DTX for Full Rate TCHs, shall not for Half Rate TCHs). . SHLFSHNH(MS shall use DTX for Full Rate TCHs, shall not for Half Rate TCHs). SHNFSHNH (MS shall not use DTX for Full Rate TCHs, shall not for Half Rate TCHs). MAYFMAYH(MS may use DTX for Full Rate TCHs, may use for Half Rate TCHs). 1530 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller DUR DWPTSCANAINTEX EADVCMPDCMHO EANTHOP SHLFSHLH (MS shall use DTX for Full Rate TCHs, shall for Half Rate TCHs). SHNFSHLH (MS shall not use DTX for Full Rate TCHs, shall for Half Rate TCHs) <DEFAULT> (default value: SHLFSHNH) Contained in the following commands: CREATE BTS, GET BTS, SET BTS Duration of measurement expressed in minutes. Validity range: duration 1..65535; Contained in the following commands: FREQMEAS SYNE This attribute controls the algorithm for averaging the interference signal for each of the 256 chips of DwPTS of each antenna per cell basis. Validity range: dwPtsCancelAvIntensExp 0..8 <DEFAULT> (default value: 4) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This attribute is used to enable/disable the advanced Compres- sion/Decompression Handover algorithm. The advanced algorithm considers the current power control situation when deciding on whether to compress (HO from FR to HR) or decompress (HO from HR to FR) a cell. A change of the attribute becomes effective in the next SACCH multiframe. Validity range: enableAdvComprDecomprHO TRUE FALSE <NULL> (default value: TRUE) Contained in the following commands: GET HAND,SET HAND This parameter indicates whether Antenna Hopping is enabled or disabled for the BTS. Validity range: enableAntennaHopping TRUE FALSE A30808-X3247-L230-3-7619 1531 Commands Base Station Controller CML:BSC EARCLM EBCCHTRX EBEAMFTX EBFONPFACH <NULL> (default value: FALSE) Contained in the following commands: CREATE BTS, GET BTS, SET BTS Flag to enable or disable the early classmark sending: that is this flag enables or disables the Multiband Handovers (from GSM900 to DCS1800 and vice versa). Validity range: enableEarlyClassmark FALSE TRUE <DEFAULT> (default value: TRUE) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD This parameter states if EDGE 8PSK modulation is supported on BCCH TRX. Validity range: egprs8pskOnBcchTrx TRUE FALSE <DEFAULT> (default value: FALSE) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter defines whether downlink beam forming is switched on or not. Validity range: enableBeamformTX TRUE FALSE <DEFAULT> (default value: TRUE) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter defines defines whether the beamforming on PFACH is switched on or not. Validity range: enableBFOnPFACH TRUE FALSE (default value: FALSE) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD 1532 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller EBSPWCR EBSPWRC EBSPWRCTD EBUSYCUM This attribute indicates whether the BS power control indicated must be corrected. The correction of BS power control is applied in the system information message with the following rules: EBSPWRC EBSPWCR SYS INFO TRUE TRUE 0 TRUE FALSE 1 FALSE TRUE 0 FALSE FALSE 0 NOTE: this parameter does not affect AMR calls. Validity range: enableBsPwrCorrection FALSE TRUE (default value: TRUE) Contained in the following commands: GET PWRC, SET PWRC This attribute enables BS Power Control and also indicates the used BS Power Control method. Validity range: enableBsPowerControl DISABLED CLASSIC ADAPTIVE (default value: ADAPTIVE for SW version = BR7.0) (default value: CLASSIC for SWversion = BR6.0) Contained in the following commands: GET PWRC, SET PWRC This attribute enables TD-SCDMA BS Power Control and also indi- cates the used BS Power Control method. Validity range: enableBsPowerControlTD TRUE FALSE <DEFAULT> (default value: TRUE) Contained in the following commands: GET PWRCTD, SET PWRCTD This parameter allows to enable or disable the Busy Cumulative Measures. Validity range: enableBusyCumulMeas TRUE FALSE <DEFAULT> A30808-X3247-L230-3-7619 1533 Commands Base Station Controller CML:BSC EC EDONOPCSSYMDL EDONOPCSSYMUL EDONOSCSSYM (default value: FALSE) Contained in the following commands: CREATE SCA, GET SCA, SET SCA This attribute determines whether emergency calls are allowed to all MSs or restricted to MSs belonging to access classes in the range from 11 to 15. The value TRUE indicates that emergency calls are restricted. The special access class 10 is used to carry the value on the Air interface. Validity range: emergencyCall FALSE TRUE <DEFAULT> (default value: FALSE) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD This parameter defines whether the power control command of downlink, DO NOTHING, is allowed or not. Validity range: enableDoNothingPCSymDL TRUE FALSE <DEFAULT> (default value: TRUE) Contained in the following commands: GET PWRCTD, SET PWRCTD This parameter defines whether the power control command of uplink, DO NOTHING, is allowed or not. Validity range: enableDoNothingPCSymUL TRUE FALSE <DEFAULT> (default value: FALSE) Contained in the following commands: GET PWRCTD, SET PWRCTD This parameter defines whether the synchronisation control command of uplink, DO NOTHING, is allowed or not. Validity range: enableDoNothingSCSym TRUE FALSE <DEFAULT> (default value: FALSE) Contained in the following commands: GET PWRCTD, SET PWRCTD 1534 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller EEICM EEOTD EEXCDIST EFRSUPP EFULHO This parameter allows to enable or disable the Extended Idle Channel Measures. Validity range: enableExtIdleChanMeas TRUE FALSE <DEFAULT> (default value: FALSE) Contained in the following commands: CREATE SCA, GET SCA, SET SCA This parameter represents the flag to enable the setting of TSC (Training Sequence Code) equal to BCC (BS Colour Code) for all channels transmitting on BCCH frequency. Validity range: enableEOTD TRUE FALSE <DEFAULT> (default value: FALSE) Contained in the following commands: CREATE BTS, GET BTS, SET BTS The attribute indicates whether the sending of call release is enabled/disabled when the distance between Mobile Station and BTS exceeds the excessive Distance. Validity range: enableExcessiveDistance FALSE TRUE <DEFAULT> (default value: FALSE) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD. This attribute indicates if the enhanced full rate is supported/allowed in the Network Element controlled by BSC. Validity range: enhanceFullRateSupport FALSE, TRUE (default value: FALSE) Contained in the following commands: GET BSC, SET BSC This parameter allows to enable or disable the Fast Uplink Handover. Validity range: enableFastUpLinkHo TRUE FALSE A30808-X3247-L230-3-7619 1535 Commands Base Station Controller CML:BSC EGPLGPEIGHTTS EGPLGPFIVETS EGPLGPFOURTS EGPLGPONETS EGPLGPSEVENTS <NULL> (default value: FALSE) Contained in the following commands: GET HAND, SET HAND This parameter suggests the polling period to be used if eight timeslots are assigned. Validity range: egprsPollingPeriodEightTimeSlot 8..64 <NULL> (default value: 16) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter suggests the polling period to be used if five timeslots are assigned. Validity range: egprsPollingPeriodFiveTimeSlot 8..64 <NULL> (default value: 16) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter suggests the polling period to be used if four timeslots are assigned. Validity range: egprsWindowSizeFourTimeSlot 8..64 <NULL> (default value: 16) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter suggests the polling period to be used if one timeslot is assigned. Validity range: egprsPollingPeriodOneTimeSlot 8..64 <NULL> (default value: 16) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter suggests the polling period to be used if seven timeslots are assigned. Validity range: egprsPollingPeriodSevenTimeSlot 8..64 <NULL> 1536 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller EGPLGPSIXTS EGPLGPTHREETS EGPLGPTWOTS EGWSEIGHTTS (default value: 16) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter suggests the polling period to be used if six timeslots are assigned. Validity range: egprsPollingPeriodSixTimeSlot 8..64 <NULL> (default value: 16) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter suggests the polling period to be used if three timeslots are assigned. Validity range: egprsPollingPeriodThreeTimeSlot 8..64 <NULL> (default value: 16) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter suggests the polling period to be used if two timeslots are assigned. Validity range: egprsPollingPeriodTwoTimeSlot 8..64 <NULL> (default value: 16) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter suggests the windowsize to be used if eight timeslots are assigned. Validity range: egprsWindowSizeEightTimeSlot WS64 WS96 WS128 WS160 WS192 WS224 WS256 WS288 WS320 WS352 WS384 WS416 WS448 WS480 WS512 WS544 WS576 WS608 WS640 WS672 WS704 WS736 WS768 WS800 A30808-X3247-L230-3-7619 1537 Commands Base Station Controller CML:BSC EGWSFIVETS EGWSFOURTS EGWSONETS WS832 WS864 WS896 WS928 WS960 WS992 WS1024 <NULL> (default value: 192) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter suggests the window size to be used if five timeslots are assigned. Validity range: egprsWindowSizeFiveTimeSlot WS64 WS96 WS128 WS160 WS192 WS224 WS256 WS288 WS320 WS352 WS384 WS416 WS448 WS480 WS512 WS544 WS576 WS608 WS640 <NULL> (default value: 128) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter suggests the window size to be used if four timeslots are assigned. Validity range: egprsWindowSizeFourTimeSlot WS64 WS96 WS128 WS160 WS192 WS224 WS256 WS288 WS320 WS352 WS384 WS416 WS448 WS480 WS512 <NULL> (default value: 96) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter suggests the window size to be used if one timeslot is assigned. Validity range: egprsWindowSizeOneTimeSlot WS64 WS96 1538 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller EGWSSEVENTS EGWSSIXTS WS128 WS160 WS192 <NULL> (default value: 64) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter suggests the window size to be used if seven timeslots are assigned. Validity range: egprsWindowSizeSevenTimeSlot WS64 WS96 WS128 WS160 WS192 WS224 WS256 WS288 WS320 WS352 WS384 WS416 WS448 WS480 WS512 WS544 WS576 WS608 WS640 WS672 WS704 WS736 WS768 WS800 WS832 WS864 WS896 <NULL> (default value: 160) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter suggests the window size to be used if six timeslots are assigned. Validity range: egprsWindowSizeSixTimeSlot WS64 WS96 WS128 WS160 WS192 WS224 WS256 WS288 WS320 WS352 WS384 WS416 WS448 WS480 WS512 WS544 WS576 WS608 WS640 WS672 WS704 WS736 WS768 <NULL> (default value: 160) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF A30808-X3247-L230-3-7619 1539 Commands Base Station Controller CML:BSC EGWSTHREETS EGWSTWOTS EHRACT EHRACTAMR This parameter suggests the windowsize to be used if three timeslots are assigned. Validity range: egprsWindowSizeThreeTimeSlot WS64 WS96 WS128 WS160 WS192 WS224 WS256 WS288 WS320 WS352 WS384 <NULL> (default value: 96) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter suggests the window size to be used if two timeslots are assigned. Validity range: egprsWindowSizeTwoTimeSlot WS64 WS96 WS128 WS160 WS192 WS224 WS256 <NULL> (default value: 64) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter allows to enable or disable the cell load dependent activation of half rate. Validity range: enableHrActivation TRUE FALSE <DEFAULT> (default value: FALSE) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter allows to enable or disable the cell load dependent activation of half rate feature for AMR calls. Validity range: enableHrActivationAmr TRUE FALSE <DEFAULT> (default value: TRUE) Contained in the following commands: GET BSC, SET BSC 1540 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller EICNF<nn> EINSYSTEMHO EISDCCHHO ELEVHOM Thirty two parameters are provided (<nn> from 1 to 32). This parameter defines a frequency for Extended Idle Channel Measures observation. Validity range: extIdleChanFreq<nn> 0..1023 <NULL> Contained in the following commands: CREATE SCA, GET SCA, SET SCA This parameter defines whether BTSC is allowed to request a handover to GSM djacent cells. Validity range: enableInterSystemHO TRUE FALSE <DEFAULT> (default value:FALSE) Contained in the following commands: GET HANDTD, SET HANDTD This attribute allows to enable/disable MSC-controlled SDCCH handovers (Directed Retry). It simply prevents the sending of HO RDQ message for SDCCH connections to the MSC. If it is set to "disable" the BSC skips all cell identifiers of the target cell list of the intercell HO Cond. message which belong to another BSC area. This parameter should be set at "disable" if MSC does not support Directed Retry. Validity range: enableInterSdcchHo ENABLED DISABLED (default value: ENABLED) Contained in the following commands: GET BSC, SET BSC This parameter indicates if level handover margin (RXLEV_NCELL(n) > RXLEV_DL + LHOMARGIN) is enabled or disabled. Validity range: enableLevHOMargin TRUE FALSE <NULL> (default value: FALSE) Contained in the following commands: GET HAND, SET HAND A30808-X3247-L230-3-7619 1541 Commands Base Station Controller CML:BSC ELIMITCH ELKADPT EMCSFAMA1DL EMCSFAMAP1DL EMCSFAMB1DL This attribute is used to enable/disable the Limitation of Intracell Handover repetition feature. Validity range: enableLimitationIntraCellHo FALSE TRUE (default value: TRUE) Contained in the following commands: GET HAND, SET HAND, GET HANDTD, SET HANDTD This parameter enables or disables Link Adaptation algorithm. This could be useful if a BVC has strange radio conditions or for testing purposes. Validity range: enableLinkAdaptation TRUE FALSE (default value: FALSE) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute enables MCS belonging to Family A and MCS1 to be used, in Downlink case. Validity range: enMcsFamAMcs1Downlink TRUE FALSE <NULL> (default value: TRUE) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute enables MCS belonging to Family A padding and MCS1 to be used, in Downlink case. Validity range: enMcsFamAPaddingMcs1Downlink TRUE FALSE <NULL> (default value: FALSE) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute enables MCS belonging to Family B and MCS1 to be used, in Downlink case. Validity range: enMcsFamBMcs1Downlink TRUE FALSE <NULL> 1542 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller EMCSFAMCDL EMCSFAMGDL EMFA1UNIR8PSK EMFAP1UNIR8PSK (default value: FALSE) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute enables MCS belonging to Family C to be used, in Downlink Case. Validity range: enMcsFamCDownlink TRUE FALSE <NULL> (default value: FALSE) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute enables MCS belonging to Family Gmsk to be used, in Downlink case. Validity range: enMcsFamGmskDownlink TRUE FALSE <NULL> (default value: FALSE) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute enables MCS belonging to FamilyA and MCS1 to be used, if MS supports 8PSK modulation in Uplink EGPRS TBF and Incremental Redundancy does not work. Validity range: enMcsFamAMcs1UplinkWoutIncrRed8Psk TRUE FALSE <NULL> (default value: TRUE) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute enables MCS belonging to Family A padding and MCS1 to be used, if MS supports 8PSK modulation in Uplink EGPRS TBF and Incremental Redundancy does not work. Validity range: enMcsFamApMcs1UplinkWoutIncrRed8Psk TRUE FALSE <NULL> (default value: FALSE) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF A30808-X3247-L230-3-7619 1543 Commands Base Station Controller CML:BSC EMFB1UNIR8PSK EMFCUNIR8PSK EMFCUNIRGMSK EMFGUNIR8PSK This attribute enables MCS belonging to Family B and MCS1 to be used, if MS supports 8PSK modulation in Uplink EGPRS TBF and Incremental Redundancy does not work. Validity range: enMcsFamBMcs1UplinkWoutIncRed8Psk TRUE FALSE <NULL> (default value: FALSE) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute enables MCS belonging to Family C to be used, if MS supports 8PSK modulation in Uplink EGPRS TBF and Incremental Redundancy does not work. Validity range: enMcsFamCUplinkWoutIncRed8Psk TRUE FALSE <NULL> (default value: FALSE) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute enables MCS belonging to Family C to be used, if MS does not support 8PSK modulation in Uplink EGPRS TBF and Incremental Redundancy does not work. Validity range: enMcsFamCUplinkWoutIncrRedGmsk TRUE FALSE <NULL> (default value: FALSE) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute enables MCS belonging to Family Gmsk to be used, if MS supports 8PSK modulation in Uplink EGPRS TBF and Incremental Redundancy does not work. Validity range: enMcsFamGmskUplinkWoutIncRed8Psk TRUE FALSE <NULL> (default value: FALSE) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF 1544 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller EMFGUNIRGMSK EMSPWRC EMT1 EMT2 This attribute enables MCS belonging to Family Gmsk to be used, if MS does not support 8PSK modulation in Uplink EGPRS TBF and Incremental Redundancy does not work. Validity range: enMcsFamGmskUplinkWoutIncrRedGmsk TRUE FALSE <NULL> (default value: TRUE) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute enables MS Power Control and also indicates the used MS Power Control method. Validity range: enableMSPowerControl DISABLED CLASSIC ADAPTIVE (default value: ADAPTIVE for SW version = BR7.0) (default value: CLASSIC for SWversion = BR6.0) Contained in the following commands: GET PWRC, SET PWRC This attribute indicates the delay for the transition to the emergency configuration in case of breakdown of the BTSE primary voltage supply if a battery backup is available in the BTSE itself. The transition includes the powerdown of TRX related equipment. Validity range: emergencyTimer1 0..1400 minutes <DEFAULT> (default value: 10 minutes) Contained in the following commands: CREATE BTSM, GET BTSM, SET BTSM This attribute indicates the delay for the transition to the zero carrier configuration in case of breakdown of the BTSE primary voltage supply if a battery backup is available in the BTSE itself. The value 0 means the EMT2 is not valid, i.e. the BTSE will not switch to a zero carrier configuration. Validity range: emergencyTimer2 0..1400 minutes <DEFAULT> (default value: 10 minutes) Contained in the following commands: CREATE BTSM, GET BTSM, SET BTSM A30808-X3247-L230-3-7619 1545 Commands Base Station Controller CML:BSC EEDGE EGPRS ENANCD ENCALSUP This parameter allows to enable/disable EGPRS (EDGE GPRS) on cell basis. Validity range: enableEdge TRUE FALSE <DEFAULT> (default value: FALSE) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter allows to enable/disable GPRS on cell basis. Validity range: enableGprs TRUE FALSE <DEFAULT> (default value: FALSE) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This flag enables or disables the procedure of detection of sleeping cell condition. Validity range: enableNoCallDetection ENABLED DISABLED <DEFAULT> (default value: DISABLED) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD The ENCALSUP (Encryption Algorithm Supported) parameter defines the algorithms for the radio interface ciphering supported by the BSC. It consists of a list of 10 items; for each item the field ENCRALGOR can be set. Validity range: encryptionAlgorSupport 1 to 10 items max list (ENCALSUP1&ENCALSUP2.....) For each item ENCALSUP<n> the ENCRALGOR field can be set at: NOENCR means no ciphering GSMV1 represents the ciphering algorithm A5/1 GSMV2 represents the ciphering algorithm A5/2 (default value: ENCALSUP1=NOENCR, ENCALSUP2=GSMV1, 1546 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller ENMDL ENFOIAHO ENFORCHO ENHSCSD ENCALSUP3 to ENCALSUP10= NOCONFIG) Contained in the following commands: GET BSC, SET BSC This parameter allows to enable or disable the Normal Measures. Validity range: enableNormalMeas TRUE FALSE <DEFAULT> (default value: FALSE) Contained in the following commands: CREATE SCA, GET SCA, SET SCA This attribute indicates whether the Forced Intracell Handover procedure is activated or not. Validity range: enableForcedIntracellHo FALSE TRUE (default value: FALSE) Contained in the following commands: GET BSC, SET BSC This attribute enables/disables the sending of Forced HO Request messages for running SDCCH connections (i.e. queued or not queued ASS REQ's which do not find an empty TCH). It is used to enable/disable Directed Retry. This attribute should be set to "disabled" if in a network the MSC which the BSS is connected to or other adjacent BSSs do not support the prevention of "back-HO". Validity range: enforceHo ENABLED DISABLED (default value: ENABLED) Contained in the following commands: GET BSC, SET BSC This attribute indicates whether the HSCSD service is activated at BSC side or not. Validity range: enableHSCSD FALSE TRUE (default value: FALSE) Contained in the following commands: GET BSC, SET BSC A30808-X3247-L230-3-7619 1547 Commands Base Station Controller CML:BSC EPOOL ENSWBCS ENVANAME EPA The EPOOL (enablePooling) parameter indicates whether the pooling feature is activated on the BSC side. Validity range: enablePooling TRUE FALSE <DEFAULT> (default value: FALSE) Contained in the following commands: GET BSC, SET BSC This parameter allows to enable/disable the switched beams for circuit switched services. Validity range: enableSwitchedBeamCS TRUE FALSE <DEFAULT> (default value: FALSE) Contained in the following commands: CREATE SWIBEAM, GET SWIBEAM, SET SWIBEAM This parameter represents the alarm type identifier. The meaning of the setting values is the following: SMOKE Smoke detection alarm. INTR Intrusion detection alarm. TRANSMEQP Transmission equipment alarm. MAINPWRSUPP Main power supply alarm. OPERATORDEF Operator defined alarm. DOOR_OPEN Enclosure door open alarm. FIRE Fire detected alarm. HEAT_VENT Air conditioning equipment alarm. HUMIDITY Humidity unacceptable alarm. TEMPERATURE Temperature unacceptable alarm. Validity range: envaName SMOKE INTR TRANSMEQP MAINPWRSUPP OPERATORDEF DOOR_OPEN FIRE HEAT_VENT HUMIDITY TEMPERATURE Contained in the following commands: CREATE ENVA, GET ENVA, SET ENVA This parameter allows to enable/disable the Enhanced Pairing for TCH/H channels feature. Validity range: enablePairing TRUE FALSE 1548 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller EPAT1 EPAT2 EPRE EPREHSCSD EPWCRLFW (default value: FALSE) Contained in the following commands: GET BSC, SET BSC This parameter is the threshold that indicates the percentage of idle TCHs in case of standard cell or complete area of a concentric cell. Validity range: enhancedPairingThreshold1 0..10000 <DEFAULT> (default value: 6000) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter is the threshold that indicates the percentage of idle TCHs in case of inner area of a concentric cell or near area of an extended cell. Validity range: enhancedPairingThreshold2 0..10000 <DEFAULT> (default value: 6000) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This attribute is used to enable/disable the Preemption feature. Validity range: enablePreemption DISABLED ENABLED <DEFAULT> (default value: DISABLED) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This attribute enables Preemption for HSCSD requests (is meaningless if ENHSCSD=FALSE). Validity range: enablePreemptionHSCSD ENABLED, DISABLED (default value: DISABLED) Contained in the following commands: GET BSC, SET BSC This attribute indicates whether the MS and BS power control procedure due to radio link failure warning is enabled or disabled. Validity range: enablePowerControlRLFW FALSE TRUE A30808-X3247-L230-3-7619 1549 Commands Base Station Controller CML:BSC EQ EQUPOS ERRACT (default value: TRUE) Contained in the following commands: GET PWRC, SET PWRC This attribute is used to enable/disable queuing for TCH channels. When the Enable Queuing feature is disabled, no TCH request is queued but all TCH channels already queued are considered. Validity range: enableQueuing DISABLED ENABLED <DEFAULT> (default value: DISABLED) Contained in the following commands: CREATE BTS, GET BTS, SET BTS The attribute defines the position of the NE. Validity range: equipmentPosition 6 characters string (default value:010101) Contained in the following commands: GET BSCE, SET BSCE This parameter indicates the event type and it is composed by the following five fields: communicationFailureEvent qualityOfServiceFailureEvent processingFailureEvent equipmentFailureEvent environmentalFailureEvent Validity range: errorAct Each field can assume the following values: CRITICAL MAJOR MINOR WARNING NOFILTER FERMAINT (only for the processingFailureEvent field) (default value: NOFILTER) When errorAct is set to one threshold, all the alarms of lower and equal priority are ignored. The parameter errorAct can assume the value FERMAINT only in case of Processing Failure Event. 1550 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller ERRCORMTD ERROR ERUDGR ESUP The Processing Failure Alarms fromthe Call Processing are normally disabled, but when errorAct assumes the value FERMAINT the Processing Failure alarms from the Call Processing are enabled. Contained in the following commands: GET BSC, SET BSC This parameter defines the error correction method used for CCSS7. Validity range: ccss7ErrorCorrectionMethod BASIC_ERROR_CORRECTION PREVENTIVE_CYCLIC_RETRANS_ERR_CORR <DEFAULT> (default value: BASIC_ERROR_CORRECTION) Contained in the following commands: CREATE OPC, GET OPC, SET OPC This attribute forces the application to ask user confirmation for script abort. Validity range: error YES, NO Contained in the following commands: EXEC This flag indicates whether evaluations for rate up-downgrading for 14.4kbit/s data services are enabled or disabled. Validity range: enableRateUpDowngrade TRUE FALSE <NULL> (default value: FALSE) Contained in the following commands: GET HAND, SET HAND This attribute indicates if BSC supports EDGE. Validity range: edgeSupport TRUE FALSE <DEFAULT> (default value: FALSE) Contained in the following commands: GET BSC, SET BSC A30808-X3247-L230-3-7619 1551 Commands Base Station Controller CML:BSC ETFO ETIME ETXDIVTS EUBCHO The ETFO (Enable Tandem Free Operation) flag allows to enable or disable the TFO mode. In TFO mode the uplink TRAU frames are not decoded to 64kbit/s PCM speech samples but are transmitted in the TFO speech frames which are transported on the A interface between two TRAUs. In addition to these TFO speech frames the signalling information are transferred on the A interface. The TFOoperation is only implemented in all mobile to mobile speech calls where both TRAUs use the same GSM transcoder. Validity range: enableTFO TRUE FALSE <DEFAULT> (default value: FALSE) Contained in the following commands: CREATE TRAU, GET TRAU, SET TRAU This parameter defines the time and date in the BSS. Validity range: externalTime hour 0..23 minute 0..59 second 0..59 day 1..31 month 1..12 year 1992..2099 Contained in the following commands: GET MEL, SET MEL This parameter allows to switch between coverage mode (enabled) and standard mode (disabled). Validity range: enableTxDivTimeShift TRUE FALSE <DEFAULT> (default value: FALSE) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This attribute is used to enable/disable Better Cell HO to UMTS. Validity range: enableBetterCellHoToUmts True False <DEFAULT> <NULL> 1552 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller EUHO EUIMPHO EUSCHO EUSDCHO EXCDIST (default value: FALSE) Contained in the following commands: GET HAND, SET HAND This attribute is used to enable/disable GSM to UMTS handovers. Validity range: enableHoFromGsmToUmts True False <DEFAULT> (default value: FALSE) Contained in the following commands: GET HAND, SET HAND This attribute is used to enable/disable Imperative HO to UMTS . Validity range: enableImperativeHoToUmts True False <DEFAULT> (default value: FALSE) Contained in the following commands: GET HAND, SET HAND This attribute is used to enable/disable Sufficient Coverage Handover to UMTS. Validity range: enableSufficientUmtsCoverageHoToUmts True False <DEFAULT> (default value: FALSE) Contained in the following commands: GET HAND, SET HAND This attribute is used to enable/disable SDCCH Handover to UMTS. Validity range: enableUmtsSdcchHo True False <DEFAULT> <NULL> (default value: FALSE) Contained in the following commands: SET BSC This attribute specifies the distance limit to be used for call release. Validity range: excessiveDistance 1..100 km for Extended cells A30808-X3247-L230-3-7619 1553 Commands Base Station Controller CML:BSC EXCDISTTD EXPSWV (default value: 100 km) 1..35 km for Not Extended cells (default value: 35 km) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This attribute specifies the distance limit to be used for call release in a TD-SCDMA cell. Validity range: excessiveDistanceTD 125..32000 (step 125) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD. This parameter is a 26 characters string having the following format (SS-VV-RR-PR-LL-CL_YY-MM-DD): SS System VV Version RR Release PR Point Release LL Load Level CL Consolidation Level YY Year MM Month DD Day The ESVRString SS, VV, RR, LL and CL have to match with the version of the BTSE software load or of the TRAU software load (in dependence on the command that uses it) stored in the directory of the BSC disk. In case of BTSE software load note that: VV = 01 for BS-20, BS-21E, BS-22, BS-60, BS-61E. VV = 04 for BS-240, BS-241, BS-240SR, BS-241SR, BS-240XL, BS-240XLSR, BS-240XS, BS-242, BS-40, BS-41, BS-82. Regarding RR sub-field, note that: RR = 13, 14, 15 for BR6.0 release RR > 15 for BR7.0 release In case of TRAU software load note that: PR = 03 for BR7.0 release Validity range: expectedSwVersion 26 characters string Contained in the following commands: CREATE BTSM, GET BTSM, SET BTSM, CREATE BTSMTD, GET BTSMTD, SET BTSMTD CREATE TRAU, GET TRAU, SET TRAU 1554 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller EXTCHO EXTMEPROCCLER EXTMODE EVTYP This flag is used to enable the handover handling on the extended cell. Validity range: enableExtendedCellHo FALSE TRUE (default value:FALSE) Contained in the following commands: GET HAND, SET HAND This parameter allows to enable/disable the ISCP Extended Measurements procedure for each of the following signalling scenarios: - first Normal Assignment; - Normal Assignments following the first; - Intracell Handover Validity range: extMeasProcController FirstNormalAss TRUE FALSE (default value:FALSE) FollNormalAss TRUE FALSE (default value:FALSE) IntracellHO TRUE FALSE (default value:FALSE) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD The attribute defines, in case of extended cell, if the channel will be used in extended mode or not. Validity range: extendedMode FALSE TRUE <DEFAULT> (default value:FALSE) Contained in the following commands: CREATE CHAN, GET CHAN This attribute defines the type of monitored event. Validity range: eventType COMMUNICATION_FAILURE_EVENT QUALITY_OF_SERVICE_FAILURE_EVENT PROCESSING_FAILURE_EVENT EQUIPMENT_FAILURE_EVENT A30808-X3247-L230-3-7619 1555 Commands Base Station Controller CML:BSC FACCHQ FACCHQTD FALLBESU FASTPCTH ENVIROMENTAL_FAILURE_EVENT Contained in the following commands: GETACTIVEALARMS BSCE This attribute defines the number of FACCH-halfburst to be received for detecting a FACCH frame. Validity range: facchQual 0..7 <DEFAULT> (default value: 5) Contained in the following commands: CREATE BTS, GET BTS, SET BTS. This attribute defines the number of FACCH-halfburst to be received for detecting a FACCH frame. Validity range: facchQual 0..15 <DEFAULT> (default value: 5) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter defines the ESU (Executable Software Unit) will be used for restoring the backup" . Validity range: fallbackESU Pathname Contained in the following commands: GET BSCOSUDB, GET BSCOSUSW The FASTPCTH parameter defines the Fast Power Control Threshold. For each frame the SIR (Signal-to-Interference Ratio) is measured. If the SIR of consecutive frames is correlated very lightly, i.e. the correlation is below FASTPCTH, the SIR changes originating from fast fading cannot be forecasted and the fast power control is switched off totally. Validity range: fastPCThreshold N_<nn>_16 <nn>=00 to 16 <DEFAULT> (default value: N_03_16) Contained in the following commands: GET PWRCTD, SET PWRCTD 1556 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller FASTSCTH FBFTH FCTRL FDDARFCN FDDDIV The FASTSCTH parameter defines the Fast Synchronisation Control Threshold. For each frame the signal delay is measured; if the delay of consecutive frames is correlated very lightly, i.e. the correlation is below FASTSCTH, the delay changes originating from fast fading cannot be forecasted and the fast synchronisation control is switched off totally. Validity range: fastSCThreshold N_<nn>_16 <nn>=00 to 16 <DEFAULT> (default value: N_03_16) Contained in the following commands: GET PWRCTD, SET PWRCTD This parameter defines the fast Beamforming Threshold (BFT). For each frame the biggest eigenvalue is measured; if the biggest eigenvalue of consecutive frames is correlated very lightly, i.e. the correlation is below fastBFThreshold, the biggest eigenvalue changes originating from fast fading cannot be forecasted and the fast beamforming is switched off totally. Validity range: fastBFThreshold N_<nn>_16 <nn>=00 to 16 (default value: N_03_16) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This read-only parameter shows the status of the flow control negotiation flag. Validity range: flowControlNegotiation NOT YES (default value: YES) Contained in the following commands: GET X25A, GET X25D This parameter represents the carrier frequency. Validity range: fddArfcn 412..10838 Contained in the following commands: CREATE TGTFDD, GET TGTFDD, SET TGTFDD This parameter indicates if diversity is used or not in FDD cell. Validity range: fddDiversity NO_DIVERSITY DIVERSITY A30808-X3247-L230-3-7619 1557 Commands Base Station Controller CML:BSC FDDGQO FDDMURREP FDDQMI <DEFAULT> (default value: NO_DIVERSITY) Contained in the following commands: CREATE TGTFDD, GET TGTFDD, SET TGTFDD This parameter relates multiRAT mobiles; it indicates an offset which is applied for carrier level of serving cell; it has to be combined with the parameter FDDQMI (fddQMin). Validity range: fddGPRSQOffset ALWAYS MDB28 MDB24 MDB20 MDB16 MDB12 MDB08 MDB04 DB00 DB04 DB08 DB12 DB16 DB20 DB24 DB28 <DEFAULT> (default value: DB0) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter indicates the number of FDD UTRAN cells to include in the measurement report. Validity range: fddMultiratReporting 0..3 <DEFAULT> (default value: 0) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter is a threshold for signal Ec/No. When the FDD adjacent level carrier is higher than serving cell of FDDGQO (fddGprsqOffset) and Ec/No is higher than FDDQMI (fddQMin), fdd_ms selects the adjacent FDD cell. Validity range: fddQMin MDB20 MDB19 MDB18 MDB17 MDB16 MDB15 MDB14 MDB13 <DEFAULT> (default value: MDB20) Contained in the following commands: CREATE BTS, GET BTS, SET BTS 1558 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller FDDQO FDDREPQTY FDDSCRMC FER This parameter relates multiRAT mobiles; it indicates an offset which is applied to level of FDD serving cell. Validity range: fddQOffset ALWAYS MDB28 MDB24 MDB20 MDB16 MDB12 MDB08 MDB04 DB00 DB04 DB08 DB12 DB16 DB20 DB24 DB28 <DEFAULT> (default value: DB0) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter indicates the reporting quantity for UTRAN FDD cells. Validity range: fddReportingQuantity RSCP EC_N0 <DEFAULT> (default value: RSCP) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter represents the Primary Scrambling Code. Validity range: fddScramblingCode 0..511 Contained in the following commands: CREATE TGTFDD, GET TGTFDD, SET TGTFDD This parameter requires 7 input values which define the 8 ranges of Frame Erasure Rate (FER), in promille %0, (Input_value1, Input_value2,.., Input_value7); The allowed input values for FER are 0 to 1000, defined by means of rangeBound<n> fields (<n>=1..7). The correspondence between the Input_values and FER is the following: FER_Range0: FER<= Inputvalue1 FER_Range1:Input_value1 <FER<= Inputvalue2 FER_Range2:Input_value2 <FER<= Inputvalue3 FER_Range3:Input_value3 <FER<= Inputvalue4 FER_Range4:Input_value4 <FER<= Inputvalue5 FER_Range5:Input_value5 <FER<= Inputvalue6 A30808-X3247-L230-3-7619 1559 Commands Base Station Controller CML:BSC FERSERTYPE FHORLMO FER_Range6:Input_value6 <FER<= Inputvalue7 FER_Range6:Input_value6 <FER Validity range: frameErasureRate rangeBound1 0..1000 (default value: 10) rangeBound2 0..1000 (default value: 20) rangeBound3 0..1000 (default value: 30) rangeBound4 0..1000 (default value: 40) rangeBound5 0..1000 (default value: 50) rangeBound6 0..1000 (default value: 100) rangeBound7 0..1000 (default value: 200) Contained in the following commands: CREATE SCANCTRX, GET SCANCTRX, SET SCANCTRX, This parameter defines the service type of the TCH connections. Validity range: ferServiceType TCH_FS TCH_HS TCH_EFS TCH_FS_EFS TCH_AFS TCH_AHS TCH_HS_AHS TCH_FS_AFS TCH_EFS_AFS TCH_FS_ESF_AFS <DEFAULT> (default value: TCH_FS) Contained in the following commands: CREATE SCANCTRX, GET SCANCTRX, SET SCANCTRX This attribute defines the 'forced handover received level minimum offset' which is used by the handover decision algorithmto determine whether a neighbour cell is regarded as suitable target cell for forced handover or not. It enhances the minimumcriteria defined by the attribute RXLEVMIN (or RXLEVMINTD for TD-SCDMA system). Validity range: fHORxLevMinOffset 0..24 (1 dB step size) <NULL> 1560 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller FHORSCMIO FHSYID FILE FILENAME (default value: 6 dB) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC, CREATE ADJCTD, GET ADJCTD, SET ADJCTD This attribute defines an offset value used in forced handover. Only if the Received Signal Code Power (RSCP) of a neighbour cells DwPTS exceeds a certain threshold, the neighbour cell can be included in the target cell list. In case of forced handover, the threshold is increased by the value of this attribute. A change of the attribute becomes effective immediately. Validity range: fHORSCPMinOffset 0..24 <NULL> (default value: 6) Contained in the following commands: CREATE ADJCTD, GET ADJCTD, SET ADJCTD This parameter represents the frequency hopping system identifier used by the channel. The 0 value corresponds to no hopping setting. Validity range: frequencyHoppingID 0..10 <DEFAULT> (default value: 0) Contained in the following commands: CREATE CHAN, GET CHAN, SET CHAN This parameters defines the file name. Validity range: file 1..30 characters string (for the UPLFILE, UPLBTSLOG, UPLTRAULOG commands) 0..30 characters string (for the UPLCIDF REMINV, UPLLIDF REMINV commands) Contained in the following commands: UPLCIDF REMINV, UPLFILE, UPLLIDF REMINV, UPLBTSLOG, UPLBTSTDLOG, UPLTRAULOG This attribute defines the file to be executed. Validity range: filename 80 characters string Contained in the following commands: EXEC A30808-X3247-L230-3-7619 1561 Commands Base Station Controller CML:BSC FILETYPE FLAPDOVLTH FLOWCTH FRSTD This attribute specifies the type of file content. This attribute must be set always to EVENT_LOG. Validity range: fileType ALARM_BUFFER only for UPLBTSLOG EVENT_LOG only for UPLTRAULOG Contained in the following commands: UPLBTSLOG, UPLTRAULOG This attribute indicates the first level thresholds (in percentage) of the BTSE Radio Signalling Links (LPDLRs). It consists of two fields: upperThreshold if the signalling traffic overcomes this threshold the BTSE suspends sending measurement report messages. lowerThreshold if the signalling traffic falls below this threshold the BTSE resumes sending measurement report messages. Validity range: firstLapdOverloadThreshold <NULL> upperThreshold 10..100 (default value: 80) lowerThreshold 10..100 (default value: 70) Contained in the following commands: CREATE BTSM, GET BTSM, SET BTSM, CREATE BTSMTD, GET BTSMTD, SET BTSMTD The flow control threshold determines the percentage of receive buffers used and notifies the congestion to the remote MSC (or SMLC). Validity range: flowcThreshold 0..9 <DEFAULT> (default value: 3) (default value: 3) Contained in the following commands: CREATE OPC, GET OPC, SET OPC This attribute identifies the standard of the frame relay. Validity range: frameRelayStandard ITU, ANSI, LMI, <DEFAULT> (default value: ITU) Contained in the following commands: CREATE FRL, GET FRL, SET FRL 1562 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller FRTERM FULHOC FULRXLVMOFF GAM This attribute identifies the termination (timeslot) which the cross connection starts from. It consists of two fields: PcmLine and Tsl (timeslot). Validity range: fromTermination PcmLine Pathname (e.g. PCMA:pcman) Tsl 1..31 (for PCM30) 1..24 (for PCM24) Contained in the following commands: CREATE NUC, GET NUC This parameter indicates whether the adjacent cell is a predefined fast uplink handover cell. When searching a target cell for a fast uplink handover, cells that have the attribute FULHOC set at TRUE will be preferred to cells that have this attribute set to FALSE. Validity range: fastULHoCell TRUE FALSE <NULL> (default value: FALSE) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC The value of this parameter is used to select a target cell for fast uplink handover. The value 0 corresponds to -63 dB and the value 126 corresponds to +63 dB (0 dB correspond to 63 value). Validity range: fastULRxLevMinOffset 0..126 (1 dB step size) <NULL> (default value: 69 [6 dB]) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC This parameter defines the gamma value applied in the power control algorithm. The set value ranges from0 dB to 62 dB (2 dB step size). Validity range: gamma 0..31 <DEFAULT> (default value: 3 [6 dB]) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF A30808-X3247-L230-3-7619 1563 Commands Base Station Controller CML:BSC GASTRABISTH This parameter is used to control the switch from/to vertical/horizontal allocation strategy and the stop/restore of Abis upgrading due to Abis scarcity. It is composed of four fields. The first one (thresholdIdleAbisHV) defines the percentage of idle Abis subslots (over the available Abis subslots) under which the Vertical allocation strategy for Abis scarcity is activated. To activate the vertical allocation in case of Abis scarcity is useful to re-use in multiplexing the already allocated Abis subslots, slowing down the allocation of new Abis resources. The second one (thresholdIdleAbisVH) defines the percentage of idle Abis subslots (over the available Abis subslots) over which the Horizontal allocation can be activated again, if also the thresholds on radio resources allow that. The third one (thresholdIdleAbisSU) defines the percentage of idle Abis subslots (over the available Abis subslots) under which the PCU must disable the Abis upgrading requests to TDPC. When this threshold is overcome, the first allocation of Abis resources to a TBF is performed with the same criteria used under normal conditions (looking at the candidate initial coding scheme), but further upgrading of Abis resources is forbidden. Moreover, in case of runtime Abis release (due to worsening of radio conditions, CSpre-emption or O&M commands), the released Abis is not allowed to be allocated again to running TBFs. The main aimof this threshold is avoiding useless signalling between PCUand TDPCin case of nearly complete Abis congestion, therefore, the default value of the threshold is 0, meaning that the Abis upgrading is disabled only in case of complete Abis congestion. The secondary aim of this threshold is to avoid the allocation of additional Abis resources to running packet services in case of Abis scarcity, so that the residual Abis resources in the pool can be by preference available to set up new CS services (this will be the trend in case of vertical allocation) or even to new PS services (in case horizontal allocation is still active). Note that moving this threshold from the default value, a reduction in PS throughput is expected. The fourth one (thresholdIdleAbisRU) defines the percentage of idle Abis subslots (over the available Abis subslots) over which the Abis upgrade requests to TDPC are restored. Constraints on the Abis thresholds are: thresholdIdleAbisSU <= thresholdIdleAbisRU; thresholdIdleAbisHV <= thresholdIdleAbisVH. Note that there is no constraint between the Abis threshold to switch to vertical allocation and the Abis threshold to disable the Abis upgrade requests; the operator is free to set the one lowest than the other, and vice versa. Validity range: gprsAllocationStrategyAbisThresholds <NULL> thresholdIdleAbisHV 0..100 (default value: 10) thresholdIdleAbisVH 0..100 (default value: 20) 1564 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GASTRTH thresholdIdleAbisSU 0..100 (default value: 0) thresholdIdleAbisRU 0..100 (default value: 10) Contained in the following commands: CREATE BTSM, GET BTSM, SET BTSM The GASTRTH (gprsAllocationStrategyThresholds) parameter concerns the percentage of idle channels in the cell in order to trigger the switch between Horizontal Allocation (HA) and Vertical Allocation (VA) strategy, and in order to enable/disable the allocation of new PDCHs to extend a TBF after the first resource assignment (upgrading of packet radio resources). It consists of three fields: the first (ThresholdIdleChanHV) one indicates the threshold under which the vertical strategy is used and under which the upgrading of radio resources is disabled; note that when the upgrading of radio resources is disabled, the extension of a TBF, if necessary and possible, is performed in multiplexing over already allocated adjacent PDCHs. The second one (ThresholdIdleChanVH) represents the threshold over which the horizontal one is used. The third one (ThresholdIdleChanEU) indicates the threshold over which the upgrading of radio resources is enabled. The first field ThresholdIdleChanHV has to be lower than or equal to the second one ThresholdIdleChanVH. The second field ThresholdIdleChanVH has to be lower than or equal to the third one ThresholdIdleChanEU. The GASTRTH fields have to be intended as a percentage of free PDCHs referred to the number of available channels (TCHs and PDCHs), except the static PDTCHs, in the whole cell. The total number of idle channels changes due to GPRS and CS load. For example it is possible to switch from the horizontal allocation to the vertical one also if no CS call is going on. Validity range: gprsAllocationStrategyThresholds <DEFAULT> ThresholdIdleChanHV 0..100 <DEFAULT> (default value: 10) ThresholdIdleChanVH 0..100 <DEFAULT> (default value: 20) ThresholdIdleChanEU 0..100 <DEFAULT> (default value: 20) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF A30808-X3247-L230-3-7619 1565 Commands Base Station Controller CML:BSC GATEWAY0 GATEWAY1 GCELLRESH GDCH This attribute is the IP address of the default gateway connected to the MPCC copy 0. It is present only if either the RC or the CBC (or both) does not belong to the same IP sub-network of the BSC. The convention used for his value is the well-known dotted decimal format. Validity range: gateway0 string 0..15 chars <DEFAULT> <NULL> (default value: <NULL>) Contained in the following commands: CREATE IPLI, GET IPLI,SET IPLI This attribute is the IP address of the default gateway connected to the MPCC copy 1. It is present only if either the RC or the CBC (or both) does not belong to the same IP sub-network of the BSC. The convention used for his value is the well-known dotted decimal format. Validity range: gateway1 string 0..15 chars <DEFAULT> <NULL> (default value: <NULL>) Contained in the following commands: CREATE IPLI, GET IPLI,SET IPLI This attribute indicates the hysteresis to be subtracted from the C32 value of the neighbouring cell, when the MS is in ready state and the neighbouring cell belongs to the same Routing Area (RA). The set value ranges from 0 dB to 14 dB (2 dB step size). Validity range: gprsCellReselectHysteresis 0..7 <DEFAULT> (default value: 2 [4 dB]) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter is used to statically allocate a GPRS channel for signalling. Validity range: gprsDedicatedChannel PBCCH PCCCH <NULL> Contained in the following commands: CREATE CHAN, GET CHAN, SET CHAN 1566 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GFDDMURREP GFDDQMI GFDDREPQTY GHCSPC This parameter indicates the number FDDUTRANcells to include in the measurement report by gprs_attached mobile. Validity range: gprsFddMultiratReporting: 0...3 (step 1) <DEFAULT> <NULL> (default value: NULL) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter is a threshold for signal Ec/No. When the fdd adjacent level carrier is higher than serving cell of fddgpr- sqoffset and Ec/No is higher than fddqmin , gprs attached fdd_ms selects the adjacent fdd cell: Validity range: GprsFddQmin: MDB20 MDB19 MDB18 MDB17 MDB16 MDB15 MDB14 MDB13 <DEFAULT> <NULL> (default value: NULL) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter indicates the reporting quantity by gprs_attached mobile for UTRAN FDD cells. Validity range: GprsFddReportingQuantity: RSCP Ec_No <DEFAULT> <NULL> (default value: NULL) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute represents the Hierarchical Cell Structure priority for cell reselection. Validity range: gprsHierarchicalCellStructPriorityClass 0..7 <DEFAULT> (default value: 3) A30808-X3247-L230-3-7619 1567 Commands Base Station Controller CML:BSC GHCSTH GLK GMANMSAL <NULL> (for ADJC object only) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC, CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute indicates the signal strength threshold used in HCS cell reselection procedure. The set value ranges from -110 dB to -48 dB. Validity range: gprsHierarchycalCellStructureThreshold 0..31 (2 dB step size) <DEFAULT> (default value: 10) <NULL> (for ADJC object only) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC, CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute defines the PCMline used between SGSN and PCU. It is defined as a pathname. Mixed configuration A-interface or G-interface are admitted. This means that it is possible to create some FRL links on PCMA interface and some others on PCMG. Validity range: gprsLink pathname (e.g. OBJ1:2/OBJ2:1/OBJ3:5 ) Contained in the following commands: CREATE FRL, GET FRL This parameter indicates the maximum number of MSs that can be multiplexed within one PDCH in the cell. It is composed of two fields: the first indicates the maximum number of MSs that can be multiplexed on one PDCH in uplink direction, the second one indicates the maximum number of MSs that can be multiplexed on one PDCH in downlink direction. Validity range: gprsMaxNumberMsAllocated upLink 1..7 (default value: 7) downLink 1..16 (default value: 16) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF 1568 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GMANPRES GMANRETS GMSTXPMAC GNMULBAC The attribute defines the number of traffic channels reserved for GPRS. Validity range: gprsMaxNumberPDCHRes 0..190 <DEFAULT> (default value: 0) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter indicates for each priority level, 1 to 4, the maximum number of retransmissions allowed. Validity range: gprsMaxNumberRetransmission PRIO1 0..3 (default value: 2) PRIO2 0..3 (default value: 2) PRIO3 0..3 (default value: 2) PRIO4 0..3 (default value: 2) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter defines the maximum power level that can be used, at mobile station side, in the cell. Validity range: gprsMsTxPwrMaxCch 0..31 <DEFAULT> (default value: 2) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF, CREATE TGTPTPPKF, GET TGTPTPPKF, SET TGTPTPPKF This parameter indicates for a multiband ms the number of cells for each frequency band supported. Validity range: gprsNMultibandCell 0..3 <DEFAULT> <NULL> (default value: NULL) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF A30808-X3247-L230-3-7619 1569 Commands Base Station Controller CML:BSC GPATH GPDPDTCHA GPENTIME This parameter indicates whether or not a mobile station of a certain priority class is authorized to do a random access for request of a GPRS service. The field is coded according to the following table: PKANA packet access is not allowed in the cell; PKAAP1 packet access is allowed for priority class 1; PKAAP2 packet access is allowed for priority class 1 to 2; PKAAP3 packet access is allowed for priority class 1 to 3; PKAAP4 packet access is allowed for priority class 1 to 4; Validity range: gprsPriorityAccessThreshold PKANA PKAAP1 PKAAP2 PKAAP3 PKAAP4 <DEFAULT> (default value: PKAAP4) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute indicates the percentage of available channels dynamically dedicated by the system to GPRS traffic. These chan- nels are chosen between those traffic channels for which the GDCH is set at NULL and for which the superordinate TRX is in service and available for gprs service (GSUP set at TRUE). In order to set the GPDPDTCHA parameter the PTPPKF object must be locked. Validity range: gprsPercentageOfDinamicPdtchAvailable 0..100 <DEFAULT> (default value: 30) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute gives the duration for which the GPRS_TEMPORARY_ OFFSET is applied in cell reselection procedure. The following list shows the correspondence between selected values and real values: 0 0 0 0 0 10 seconds 0 0 0 0 1 20 seconds ... ... 1 1 1 1 1 320 seconds Validity range: gprsPenaltyTime 0..31 <DEFAULT> (default value: 0 [10 s]) <NULL> (for ADJC object only) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC 1570 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GRANP GRESOFF This attribute represents the duration in minutes of the single period of measurement. The MINUTES_5 value is not available for the SCANBTSE and SCANBTSM objects. Validity range: granularityPeriod MINUTES_5 MINUTES_15 MINUTES_30 MINUTES_ 60 <DEFAULT> (default value: MINUTES_60) Contained in the following commands: CREATE SCANAIRTSTD, GET SCANAIRTSTD, SET SCANAIRTSTD, CREATE SCANBSC, GET SCANBSC, SET SCANBSC, CREATE SCANBTS, GET SCANBTS, SET SCANBTS, CREATE SCANBTSABISTD, GET SCANBTSABISTD, SET SCAN- BTSABISTD, CREATE SCANBTSE, GET SCANBTSE, SET SCAN- BTSE, CREATE SCANBTSIHO, GET SCANBTSIHO, SET SCANBTSIHO, CREATE SCANBTSM, GET SCANBTSM, SET SCANBTSM, CREATE SCANBTSMTD, GETSCANBTSMTD, SET SCANBTSMTD, CREATE SCANBTSOHOI, GET SCANBTSOHOI, SET SCANBTSOHOI, CREATE SCANBTSOHON, GET SCANBTSOHON, SET SCANBTSOHON, CREATE SCANBTSOHOS, SET SCANBTSOHOS, CREATE SCAN- BTSTD, GET SCANBTSTD, SET SCANBTSTD, CREATE SCANBT- STDIHDO, GET SCANBTSTDIHDO, SET SCANBTSTDIHDO, CREATE SCANBTSTDOHDOI, GET SCANBTSTDOHDOI, CREATE SCANBTSTDOHDOI,CREATE SCANBTSTDOHDON, GET SCANBTSTDOHON, SET SCANBTSTDOHDON, GET SCANCHAN, GET SCANCTRX, CREATE SCANFBTSM, GET SCANFBTSM, SET SCANFBTSM, CREATE SCANGPRS, GET SCANGPRS, SET SCANGPRS, CREATE SCANGPRSTD, GET SCANGPRSTD, SET SCANGPRSTD, CREATE SCANSS7L, GET SCANSS7L, SET SCANSS7L, CREATE SCANTRX, GET SCANTRX, SET SCANTRX, CREATE SCANTRXABISTD, GET SCANTRXABISTD, SET SCANTRXABISTD, CREATE SCANT- RXTD, GET SCANTRXTD, SET SCANTRXTD This attribute specifies to mobile station the positive or negative offset and hysteresis to be applied to GPRS Reselection Criterion. The set value ranges from -52 dB to +48 dB; the step size is 4 dB for the first 11 values, 2 dB for the next 12 values and 4 dB for the last 9 values, as shown in the table below: 0 -52 dB 1 -48 dB ..... ...... 10 -12 dB 11 -10 dB ..... ...... 22 +12 dB 23 +16 dB A30808-X3247-L230-3-7619 1571 Commands Base Station Controller CML:BSC GRXLAMI GS GSUP GTDDMURREP ..... ...... 31 +48 dB Validity range: gprsReselecOffset 0..31 <DEFAULT> (default value: 16 [0 dB]) <NULL> (for ADJC object only) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC This parameter defines the minimumreceived level, at mobile station side, required for the access to the cell. Validity range: gprsLevAccessMin 0..63 <DEFAULT> (default value: 6) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF, CREATE TGTPTPPKF, GET TGTPTPPKF, SET TGTPTPPKF This parameter is used for calculation of the number of slots between two successive Channel request messages on PRACH channel. Validity range: gprsSlot 0..9 <DEFAULT> (default value: 8) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute indicates whether the GPRS service is supported or not. In the case of ADJC object it indicates whether the adjacent cell supports the GPRS service or not. In the case of TRX object it indicates whether the TRX of the serving cell supports the GPRS service or not. Validity range: gprsSupported TRUE FALSE <DEFAULT> (default value: FALSE) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC, CREATE TRX, GET TRX, SET TRX This parameter indicates the number TDDUTRANcells to include in the measurement report by gprs_attached mobile. Validity range: gprsTddMultiratReporting: 0...3 (step 1) <DEFAULT> 1572 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller GTEMPOFF GTS GTXINT <NULL> (default value: NULL) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute applies a negative offset to C31 for the duration of GPRS_PENALTY_TIME. The 7 value means infinity; the step size for values between 1 and 6 is 10 dB. Validity range: gprsTemporaryOffset 0..7 <DEFAULT> (default value: 1) <NULL> (for ADJC object only) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC This parameter defines the 64 kbit/s time slots reserved for this specific FRL either on A interface or on G interface as specified with parameter GLK. Even though the parameter consists of a list of max 31 values two different cases are foreseen: in case of PCU equipped with PPCU boards only 16 timeslots can be defined on Gb interface; in case of PCU equipped with PPXU boards up to 31 timeslots can be defined on Gb interface for each PCM line. The values must be separated by character &. Validity range: gprsTimeSlot Tsl1&Tsl2&..Tsl31 (values 1..31) Contained in the following commands: CREATE FRL, GET FRL, SET FRL This parameter defines the number of slots to spread transmission of the random access on PRACH channel. Validity range: gprsTxInterval 0..15 <DEFAULT> (default value: 3) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF A30808-X3247-L230-3-7619 1573 Commands Base Station Controller CML:BSC GUARMABIS GUMTSSRHPRI This attribute specifies the minimum percentage of in service Abis subslots of the Abis pool (configured on BTSMbasis) at disposal of a cell (BTS). When allocating new Abis resources in any cell X of a site the system guarantees that the percentage of Abis subslots still idle and in service after the Abis allocation in the cell X is equal or greater than GUARMABIS y - %BusyAbis y , for every cell Y in the site where: (GUARMABIS y != 0) and (%BusyAbis y <= GUARMABIS y ). %BusyAbis y is the percentage of Abis subslots allocated to the cell Y, calculated with respect to the total number of in service Abis subslots of the Abis pool. GUARMABIS is guaranteed under normal conditions. It is not guaranteed: 1) in case a fault or an operator command causes the outage of service of part of or all the Abis subslots in the Abis pool, as long as the other cells of the site keep allocated most of the residual in service Abis resources. 2) temporarily, after a reconfiguration that reduces the Abis pool size. 3) in case the Abis pool is heavily undersized with respect to the radio configuration. Validity range: guaranteedMinimumAbis 0..20 <NULL> (default value: 0) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter indicates if mobile gprs_attached can search 3G cells when BSIC decoding is required, i.e. if the searching time can be longer than normal value ( 13 sec. Instead of 10 sec. ). Validity range: gprsUmtsSearchPriority: TRUE FALSE <DEFAULT> <NULL> (default value: NULL) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF 1574 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller A30808-X3247-L230-3-7619 1575 Commands Base Station Controller CML:BSC HAGSMTOTDSCDMA - OVLSTTHR HAGSMTOTDSCDMA HCICN HEADER HIERC HIERF This parameter is used by calculation of power budget of GSM adjacent cells. Validity range: hoAdptGsmToTdscdma -128..127 dB (step 1 dB) <DEFAULT> (default value: -128 dB) Contained in the following commands: GET HANDTD, SET HANDTD High part of the CIC. This field identifies one among several 2 Mbit/s lines interconnecting MSC and BSS. Validity range: hCICN 0..2047, if CICFM=GSM 0..2729, if CICFM=NOTSTRUCT (default value: pcman) Contained in the following commands: CREATE PCMA, GET PCMA This parameter defines the defines the software load header file. The user can defines the header either typing the string in the field HEADER FILE or using the button Browse File. Validity range: headerfile 1..59 characters string Contained in the following commands: CREATE RSUEXE The attribute indicates whether the ranking of the target cells based on the priority layer is enabled or disabled. Validity range: enableHierarchicalCellHo FALSE, TRUE (default value: FALSE) Contained in the following commands: GET HAND, SET HAND The attribute is used to switch between two alternative ranking methods in case of imperative handover. Validity range: hierarchicalCellRankFlag 1576 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller HOAVDIST HOAVELEV Rank0 All cells where rxlev_ncell > rxLevMinCell + max(0,PA) are sorted in increasing order of priority where PBGT - hoMargin > 0, followed by those cells where PBGT - hoMargin < 0 in increasing order of priority. Having the same priority the cells are sorted by PBGT - hoMargin. Rank1 All cells where rxlev_ncell > rxLevMinCell + max(0,PA) are subdivided into two sublists 1. The upper sublist consists of all cells with: rxlev_ncell > rxLevMinCell+max(0,PA)+ levelOffsetN- cell 2. The lower sublist consists of all cells with: rxlev_ncell <= rxLevMinCell+max(0,PA)+ levelOffset- Ncell Within each sublist the cells are ordered according to their priority. Cells with the same priority are ordered according to the value of PBGT - hoMargin. (default value: Rank0) Contained in the following commands: GET HAND, SET HAND This attribute defines the averaging window size for timing advance values (absolute MS-BTS distance), used for handover decision. Validity range: hoAveragingDistance 1-31 units of 1 SACCH multiframe (step size 1) <DEFAULT> (default value: 8) Contained in the following commands: GET HAND, SET HAND, GET HANDTD, SET HANDTD This attribute defines two averaging parameters for the uplink and downlink signal strength measurements, used for handover decision. Validity range: aLevHo 1..31 (1 SACCH multiframe step size) (default value: 4) wLevHo 1..3 (1 step size) (default value: 2) Contained in the following commands: GET HAND,SET HAND A30808-X3247-L230-3-7619 1577 Commands Base Station Controller CML:BSC HOAVELEVTD HOAVPWRB HOAVPWRBTD HOAVQUAL This attribute defines two averaging parameters for the uplink and downlink signal strength measurements, used for TD-SCDMA handover decision. Validity range: aLevHo 1..31 (1 SACCH multiframe step size) (default value: 8) wLevHo 1..3 (1 step size) (default value: 2) Contained in the following commands: GET HANDTD,SET HANDTD This attribute defines the averaging window size, in SACCH periods, used for power budget evaluation. Validity range: hoAveragingPowerBudget 1-31(1 SACCH multiframe step size) (default value: 8) Contained in the following commands: GET HAND, SET HAND This attribute defines the averaging window size, in SACCH periods, used for TD-SCDMA power budget evaluation. Validity range: hoAveragingPowerBudgetTD 1-31(1 SACCH multiframe step size) <DEFAULT> (default value: 10) Contained in the following commands: GET HANDTD, SET HANDTD This attribute defines two averaging parameters for the uplink and downlink signal quality measurements, used for handover decision. Validity range: A_Qual_Ho 1-31 (1 SACCH multiframe step size) (default value: 3) w_Qual_Ho 1-3 (step size 1) (default value: 2) Contained in the following commands: GET HAND, SET HAND, GET HANDTD, SET HANDTD 1578 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller HOCCDIST HOLTHLVDL HOLTHLVUL HOLTHQAMRDL This attribute specifies the distance limit between inner and complete area of a concentric cell which is taken into account for the intracell handover in addition to the attribute HORXLVDLI respectively HORXLVDLO: .In case of TRX belonging to the inner area of a concentric cell the additional 'or' condition 'distance > HOCCDIST is evaluated. .In case of a TRX belonging to the complete area of a concentric cell the additional 'and' condition 'distance < HOCCDIST is evaluated. Validity range: hoConcentricCellDistance 0-35 km (default value: 5 km) Contained in the following commands: GET HAND, SET HAND This attribute defines the receive signal strength threshold on downlink for intercell handover decision. Validity range: hoLowerThresholdLevDL 0..63 dBr (default value: 10) For the values make references to Appendix B: Group 2. Contained in the following commands: GET HAND, SET HAND This attribute defines the receive signal strength threshold on uplink for intercell handover decision. Validity range: hoLowerThresholdLevUL 0..63 dBr (default value: 8) For the values make references to Appendix B: Group 2. Contained in the following commands: GET HAND, SET HAND This parameter determines the lower downlink quality handover threshold for AMR calls. In case of an AMR call HOLTHQAMRDL eclipses the threshold HOLTHQUDL, i.e. for AMR calls the handover algorithm triggers a handover due to quality downlink if the quality drops below the threshold determined by HOLTHQAMRDL. As HOLTHQAMRDL is entered in C/I values, but the MS reports the serving cell quality in form of RXQUAL values, the BTS performs an internal mapping of RXQUAL to C/I values prior to the downlink quality handover decision. Validity range: hoLowerThresQualAMRDL 0..30 (1 dB step size) <NULL> A30808-X3247-L230-3-7619 1579 Commands Base Station Controller CML:BSC HOLTHQAMRUL HOLTHQUDL HOLTHQUDLTD HOLTHQUUL (default value: 8) Contained in the following commands: GET HAND, SET HAND This parameter determines the lower uplink quality handover threshold for AMR calls. In case of an AMR call HOLTHQAMRUL eclipses the threshold HOLTHQUUL, i.e. for AMR calls the handover algorithmtriggers a handover due to quality uplink if the quality drops below the threshold determined by HOLTHQAMRUL. As HOLTHQAMRUL is entered in C/I values, but the BTS measures the serving cell quality in form of RXQUAL values, the BTS performs an internal mapping of RXQUAL to C/I values prior to the uplink quality handover decision. Validity range: hoLowerThresQualAMRUL 0..30 (1 dB step) <NULL> (default value: 8) Contained in the following commands: GET HAND, SET HAND This attribute defines the receive signal quality threshold on downlink for intercell handover decision. Validity range: hoLowerThresholdQualDL 0..7 (default value: 5) For the values make references to Appendix B: Group 3. Contained in the following commands: GET HAND, SET HAND This attribute defines the receive signal quality threshold on downlink for TD-SCDMA intercell handover decision. Validity range: hoLowerThresholdQualDLTD 1..63 <DEFAULT> (default value: 33) For the values make references to Appendix B: Group 10. Contained in the following commands: GET HANDTD, SET HANDTD This attribute defines the receive signal quality threshold on uplink for intercell handover decision. Validity range: hoLowerThresholdQualUL 0..7 (default value: 5) 1580 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller HOLTHQUULTD HOLTHRSCPDL HOLTHRSCPUL HOM For the values make references to Appendix B: Group 3. Contained in the following commands: GET HAND, SET HAND This attribute defines the receive signal quality threshold on uplink for TD-SCDMA intercell handover decision. Validity range: hoLowerThresholdQualULTD 1..63 <DEFAULT> (default value: 33) For the values make references to Appendix B: Group 10. Contained in the following commands: GET HANDTD, SET HANDTD This parameter defines the lower threshold of RSCP. If downlink RSCP below the threshold a handover is requested. Validity range: hoLowerThresholdRSCPDL -115..-25 dBm (step 1 dBm) <DEFAULT> (default value: -100 dBm) Contained in the following commands: GET HANDTD, SET HANDTD This parameter defines the threshold for uplink RSCP. If uplink RSCP below the threshold a handover is requested. Validity range: hoLowerThresholdRSCPUL -120.0..-57.0 dBm (step 0.5 dBm) (default value: -100 dBm) Contained in the following commands: GET HANDTD, SET HANDTD The value of this attribute is used as a threshold to prevent repetitive hand-over between adjacent cells, should the handover be caused by received signal level or the power budget process. The set value ranges from -63 dB to +63 dB (1 dB step size). Validity range: hoMargin 0..126 <DEFAULT> (default value: 69 [6 dB]) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC, CREATE ADJC3G, GET ADJC3G, SET ADJC3G, CREATE ADJCTD, GET ADJCTD, SET ADJCTD A30808-X3247-L230-3-7619 1581 Commands Base Station Controller CML:BSC HOMDOFF HOMDTIME HOMRGTA HOMSOFF This parameter is only relevant for speed sensitive handover. It specifies the dynamic offset by which the handover margin is reduced after expiry of the timer HOMDTIME. Validity range: hoMarginDynamicOffset 0..127 (1 dB step size) (default value: 0 dB) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC, CREATE ADJC3G, GET ADJC3G, SET ADJC3G This parameter is relevant for speed sensitive handover; it specifies the time an immediate handover request is delayed when a power budget handover is requested. Validity range: hoMarginDelayTime 0..255 (1 SACCH multiframe step size) <DEFAULT> (default value: 0) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC, CREATE ADJC3G, GET ADJC3G, SET ADJC3G This attribute specifies the threshold for the maximumtiming advance in a single timeslot. Validity range: hoMarginTa 0..35 km (default value: 4 km) Contained in the following commands: GET HAND, SET HAND This parameter is only relevant for speed sensitive handover; it specifies the static offset by which the handover margin is increased as long as the timer HOMDTIME runs. Validity range: hoMarginStaticOffset 0..127 (1 dB step size) <DEFAULT> (default value: 0) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC, CREATE ADJC3G, GET ADJC3G, SET ADJC3G 1582 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller HOMSTAM HOPMODE HOPP HORXLVDLI This attribute specifies the maximum allowed MS-BTS distance to use a single timeslot channel. Validity range: hoMsTaMax 0..34 km (default value: 32 km) Contained in the following commands: GET HAND, SET HAND This attribute indicates whether baseband hopping or synthesizer hopping is to be done. Validity range: hoppingMode BBHOP SYNHOP (default value: BBHOP) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This attribute specifies whether frequency hopping is enabled or not. The actual frequency hopping status is reported in the field BTS IS HOPPING (refer to GETINFO BTS command). Validity range: enableHopping FALSE (frequency hopping not used) TRUE (frequency hopping use) <DEFAULT> (default value: FALSE) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This attribute defines the receive signal strength threshold on downlink which is evaluated for the intracell handover from a TRX belonging to the inner area to a TRX belonging to the complete area of a concentric cell. Validity range: hoRxlevDLinner 0-63 dBr (default value: 26) For the values make reference to Appendix B: Group 2. Contained in the following commands: GET HAND, SET HAND A30808-X3247-L230-3-7619 1583 Commands Base Station Controller CML:BSC HORXLVDLO HOSYNC HOTDLINT HOTHAMRCDL This attribute defines the receive signal threshold level on downlink which is evaluated for the intracell handover froma TRX belonging to the complete area to a TRX belonging to the inner area of a concentric cell. Validity range: hoRxlevDLouter 0-63 dBr (default value: 32) For the values make reference to Appendix B: Group 2. Contained in the following commands: GET HAND, SET HAND This attribute is a flag to enable/disable the synchronized handover between cells belonging to the same site. Validity range: handoverSynchronization NONSYNC SYNC (default value: NONSYNC) Contained in the following commands: GET BSC, SET BSC This attribute defines the receive signal strength threshold on downlink for intracell handover decision. Validity range: hoThresholdLevDLintra 0..63 dBr (default value: 35 dBr) For the values make references to Appendix B: Group 2. Contained in the following commands: GET HAND, SET HAND This parameter represents the downlink quality threshold used to trigger an intracell AMR Compression Handover "fullrate to halfrate". The purpose of this handover is to transfer AMR calls with excellent speech quality that currently occupy an AMR FR TCH to an AMR HR TCH in order to use the TCH resources more efficiently. AMR compression handover (AMR fullrate to AMR halfrate) is triggered only if both the thresholds for UL quality and DL quality (HOTHAMRCDL and HOTHAMRCUL) are exceeded. As HOTHAMRCDL is entered in C/I values, but the MS reports the serving cell quality in form of RXQUAL values, the BTS performs an internal mapping of RXQUAL to C/I values prior to the AMR compression handover decision. Validity range: hoThresAMRComprDL 0..30 (1 dB step) <NULL> 1584 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller HOTHAMRCUL HOTHAMRDDL (default value: 23) Contained in the following commands: GET HAND, SET HAND This parameter represents the uplink quality threshold used to trigger an intracell AMR Compression Handover "fullrate to halfrate". The purpose of this handover is to transfer AMR calls with excellent speech quality that currently occupy an AMR FR TCH to an AMR HR TCH in order to use the TCH resources more efficiently. AMR compression handover (AMR fullrate to AMR halfrate) is triggered only if both the thresholds for UL quality and DL quality (HOTHAMRCDL and HOTHAMRCUL) are exceeded. As HOTHAMRCUL is entered in C/I values, but the BTS measures the serving cell quality in form of RXQUAL values, the BTS performs an internal mapping of RXQUAL to C/I values prior to the AMR compression handover decision. Validity range: hoThresAMRComprUL 0..30 (1 dB step) <NULL> (default value: 23) Contained in the following commands: GET HAND, SET HAND This parameter represents the downlink quality threshold used to trigger an intracell AMR Decompression Handover "halfrate to fullrate". The purpose of this handover is to transfer AMR calls with poor speech quality that currently occupy an AMR HR TCH to an AMR FR TCH in order to improve the speech quality. In contrast to the intracell AMR compression handover (see parameter HOTHAMRCDL), the Intracell AMR decompression handover "halfrate to fullrate" is triggered if either the DL quality drops belowthe threshold HOTHAMRDDL or the UL quality drops belowthe threshold HOTHAMRDUL. As HOTHAMRDDL is entered in C/I values, but the MS reports the serving cell quality in form of RXQUAL values, the BTS performs an internal mapping of RXQUAL to C/I values prior to the AMR decompression handover decision. Validity range: hoThresAMRDecomprDL 0..30 (1 dB step) <NULL> (default value: 10) Contained in the following commands: GET HAND, SET HAND A30808-X3247-L230-3-7619 1585 Commands Base Station Controller CML:BSC HOTHAMRDUL HOTHCMPLVDL HOTHCMPLVUL HOTHDCMLVDL This parameter represents the uplink quality threshold used to trigger an intracell AMR Decompression Handover "halfrate to fullrate". The purpose of this handover is to transfer AMR calls with poor speech quality that currently occupy an AMR HR TCH to an AMR FR TCH in order to improve the speech quality. In contrast to the intracell AMR compression handover (see parameter HOTHAMRCUL), the Intracell AMR decompression handover "halfrate to fullrate" is triggered if either the DL quality drops belowthe threshold HOTHAMRDDL or the UL quality drops below the threshold HOTHAMRDUL. As HOTHAMRDUL is entered in C/I values, but the BTS measures the serving cell quality in form of RXQUAL values, the BTS performs an internal mapping of RXQUAL to C/I values prior to the AMR decompression handover decision. Validity range: hoThresAMRDecomprUL 0..30 (1 dB step) <NULL> (default value: 10) Contained in the following commands: GET HAND, SET HAND This attribute defines the downlink condition for triggering a compres- sion handover. Validity range: hoThresComprLevDL 0..63 (step 1 dBm) (0 = -110 dBm 63 = 48 dBm) <NULL> (default value: 40) Contained in the following commands: GET HAND,SET HAND This attribute defines the uplink condition for triggering a compression handover. Validity range: hoThresComprLevUL 0..63 (step 1 dBm) (0 = -110 dBm 63 = 48 dBm) <NULL> (default value: 40) Contained in the following commands: GET HAND,SET HAND This attribute defines the downlink condition for triggering a decom- pression handover. Validity range: hoThresDecomprLevDL 0..63 (step 1 dBm) (0 = -110 dBm 63 = 48 dBm) 1586 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller HOTHDCMLVUL HOTHRSCPDLIRA HOTHRSCPULIRA HOTMSRM <NULL> (default value: 26) Contained in the following commands: GET HAND,SET HAND This attribute defines the uplink condition for triggering a decompres- sion handover. Validity range: hoThresDecomprLevUL 0..63 (step 1 dBm) (0 = -110 dBm 63 = 48 dBm) <NULL> (default value: 26) Contained in the following commands: GET HAND,SET HAND This parameter defines the threshold of the RSCP on downlink for a intracell handover. If the quality is below a threshold and the RSCP is above the threshold defined by this attribute an intracell handover is requested. Validity range: hoThresholdRSCPDLintra -115..-25 dBm (step 1 dBm) <DEFAULT> (default value: -90 dBm) Contained in the following commands: GET HANDTD, SET HANDTD This parameter defines the threshold of the RSCP on uplink for a intracell handover. If the quality is below a threshold and the RSCP is above the hreshold defined by this attribute an intracell handover is requested. Validity range: hoThresholdRSCPULintra -120.0..-80.0 dBm (step 0.5) <DEFAULT> (default value: -90 dBm) Contained in the following commands: GET HANDTD, SET HANDTD This attribute specifies the maximum allowed MS-BTS distance for the current cell. Validity range: hoThresholdMsRangeMax 0..35 (1 km step size) A30808-X3247-L230-3-7619 1587 Commands Base Station Controller CML:BSC HOTMSRME HOTMSRMTD HOTULINT HRACTAMRT1 (default value: 34) Contained in the following commands: GET HAND, SET HAND This attribute specifies the maximum allowed MS-BTS distance for the extended cell. Validity range: hoThresholdMsRangeMaxExt 35..100 km (1 km step size) (default value: 99 km) Contained in the following commands: GET HAND, SET HAND This attribute specifies the maximum allowed MS-BTS distance for the current TD-SCDMA cell. Validity range: hoThresholdMsRangeMaxTD 0..35 (1 km step size) (default value: 34) Contained in the following commands: GET HANDTD, SET HANDTD This attribute defines the receive signal strength threshold on uplink for intracell handover decision. Validity range: hoThresholdLevULintra 0..63 dBr (default value: 35 dBr) For the values make references to Appendix B: Group 2. Contained in the following commands: GET HAND, SET HAND This parameter is the threshold that indicates, in case of AMRcalls, the percentage of busy TCHs in case of standard cell or complete area of a concentric cell or far area of an extended cell. Validity range: hRActivationAmrThreshold1 0..10000 <DEFAULT> (default value: 6000) Contained in the following commands: CREATE BTS, GET BTS, SET BTS 1588 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller HRACTAMRT2 HRACTT1 HRACTT2 HRDATA HREFRLDTH This parameter is the threshold that indicates, in case of AMRcalls, the percentage of busy TCHs in case of inner area of a concentric cell or near area of an extended cell. Validity range: hRActivationAmrThreshold2 0..10000 <DEFAULT> (default value: 6000) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter is the threshold that indicates the percentage of busy TCHs in case of standard cell or complete area of a concentric cell or far area of an extended cell. Validity range: hRActivationThreshold1 0..10000 <DEFAULT> (default value: 6000) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter is the threshold that indicates the percentage of busy TCHs in case of inner area of a concentric cell or near area of an extended cell. Validity range: hRActivationThreshold2 0..10000 <DEFAULT> (default value: 6000) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This read-only parameter defines whether the half rate data service is supported or not. Validity range: halfRateDataSupported FALSE TRUE (default value: FALSE) Contained in the following commands: GET BSC This parameter defines the percentage threshold of busy RUs; it is used for assignment policy of HR / EFR radio resources. Validity range: hREFRLoadThreshold 0..100 (1/100 s step ize) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD. A30808-X3247-L230-3-7619 1589 Commands Base Station Controller CML:BSC HRSPEECH HSN IDBSCESUDB IDBSCESUSW This attribute controls the Half Rate Speech service activation. Validity range: halfRateSpeechSupported FALSE TRUE (default value: FALSE) Contained in the following commands: GET BSC, SET BSC It determines the sequence in which the hopping is done. When HSN = 0 a cyclic hopping sequence is used, else the value is used as a generator value for pseudo random hopping sequence. Validity range: hoppingSequenceNumber 0..63 Contained in the following commands: CREATE FHSY, GET FHSY, SET FHSY This parameter defines the identifier of the BSC Executable Software Unit DB; it consists of two fields but only one can be used (NAME or USER LABEL DB). The BSCESUDB validity range is 0..19. Validity range: identifierBSCESUDB NAME: Pathname (e.g. BSCESUDB:0) USER LABEL DB: 1..30 characters string Contained in the following commands: GET BSCESUDB, GET BSCESUDB BASICS, GET BSCESUDB STAT,GETINFO BSCESUDB, SET BSCOSUDB This parameter defines the identifier of the BSC Executable Software Unit SW; it consists of two fields but only one can be used (NAME or USER LABEL SWLH). The BSCESUSW validity range is 0..19. Validity range: identifierBSCESUSW NAME: Pathname (e.g. BSCESUSW:0) USER LABEL SWLH: 1..30 characters string Contained in the following commands: GET BSCESUSW, GET BSCESUSW BASICS, GET BSCESUSWSTAT, GETINFOBSCESUSW, SET BSCOSUSW 1590 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller IDNEYESUSW IDRSUDB IDRSUEXE This parameter defines the identifier of the Executable Software Unit SW for the NE; it consists of two fields but only one can be used (NAME or Label Access). The NEYESUSW validity range is 0..39. Validity range: identifierNEYESUSW NAME: pathname (e.g. NEYESUSW:0) Label Access: it consists of the two sub-fields: USER LABEL SWLH: 1..30 characters string NETWORK ELEMENT: BTSE, TRAU Contained in the following commands: GET NEYESUSW, GET NEYESUSW BASICS, GET NEYESUSW STAT, GETINFO NEYESUSW This parameter defines the identifier of the Replaceable Software Unit DataBase; it consists of two fields but only one can be used (NAME or USER LABEL DB). The RSUDB validity range is 0..19. Validity range: identifierRSUDB NAME: pathname (e.g. RSUDB:0) USER LABEL DB: 1..30 characters string Contained in the following commands: DELETE RSUDB, GET RSUDB, GET RSUDB STAT, SET RSUDB, UPLDFILE RSUDB This parameter defines the identifier of the Replaceable Software Unit Executable; it consists of two fields but only one can be used (NAME or Label Access). The user can defines the RELATED FILES either typing the string in the related field or using the button Browse File. The RSUSWLHvalidity range is 0..59 and the RSUEXEvalidity range is 0..259. Validity range: identifierRSUEXE NAME: pathname (e.g. RSUSWLH:0/RSUEXE:0) Label Access: it consists of the three sub-fields: USER LABEL SWLH: 1..30 characters string PROC TYPE: SWLH IXLT RELATED FILES: 1..59 characters string Contained in the following commands: DELETE RSUEXE, GET RSUEXE, GET RSUEXE BASICS, GET RSUEXE STAT A30808-X3247-L230-3-7619 1591 Commands Base Station Controller CML:BSC IDRSUPCH IDRSUSWLH IERCHOSDCCH This parameter defines the identifier of the Replaceable Software Unit Patch; it consists of two fields but only one can be used (NAME or Label Access). The RSUSWLH validity range is 0..59, the RSUEXE validity range is 0..259 and the RSUPCH validity range is 0..199. Validity range: identifierRSUPCH NAME: pathname (e.g. RSUSWLH:0/ RSUEXE:0/RSUPC:0) Label Access: it consists of the three sub-fields: USER LABEL SWLH: 1..30 characters string USER LABEL PCH: 1..30 characters string PROC TYPE: SWLH IXLT PPCU PPCC Contained in the following commands: DELETE RSUPCH, GET RSUPCH, GET RSUPCH BASICS, GET RSUPCH STAT, LOADPATCH RSUPCH, SET RSUPCH This parameter defines the identifier of the Replaceable Software Unit SW Load Headers; it consists of two fields but only one can be used (NAME or Label Access). The RSUSWLH validity range is 0..59. Validity range: identifierRSUSWLH NAME: pathname (e.g. RSUSWLH:0) Label Access: USER LABEL SWLH: 1..30 characters string NETWORK ELEMENT: BSC, BTSE, TRAU Contained in the following commands: DELETE RSUSWLH, GET RSUSWLH, GET RSUSWLH BASICS, GET RSUSWLH STAT, SET RSUSWLH This attribute allows a managing systemto enable or disable inter cell handovers for SDCCH channels. Validity range: enableInterCellHoSdcch FALSE TRUE <NULL> (default value: FALSE) Contained in the following commands: GET HAND, SET HAND 1592 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller IMCSULNIR8PSK IMCSULNIRGMSK IMSIATDT IMSIFSIZ This parameter suggests the MCS to be used in an EDGE TBF if no other information about that MS in that BVC is available. This parameter can be used if MS is an 8PSK MS and Incremental Redundancy is not usable in the BVC and no other information is available about that MS. Validity range: initialMcsUplinkWoutIncrRed8psk MCS1 MCS2 MCS3 MCS4 MCS5 MCS6 MCS7 MCS8 MCS9 <NULL> (default value: MCS6) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter suggests the MCS to be used in an EDGE TBF if no other information about that MS in that BVC is available. This parameter can be used if MS is a GMSK MS, Incremental Redundancy is not usable in the BVC and no other information is available about that MS. Validity range: initialMcsUplinkWoutIncrRedGmsk MCS1 MCS2 MCS3 MCS4 <NULL> (default value: MCS3) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute controls whether the IMSI attach/detach procedure is used in the cell. Validity range: allowImsiAttachDetach FALSE (IMSI attach/detach not used) TRUE (IMSI attach/detach used) <DEFAULT> (default value: TRUE) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD The attribute specifies the maximum file size (in Mbytes) for IMSI files. Validity range: imsiFileSize 0..30 A30808-X3247-L230-3-7619 1593 Commands Base Station Controller CML:BSC INIBLER INICSCH INICSCHTD (default value: 30) Contained in the following commands: GET BSC, SET BSC This attribute defines the initial BLER estimation in a cell to be used in Resource Management to calculate the initial number of radio resources to be assigned to packet services, when no historical information about BLER is available. Validity range: initialBLER PER10 PER20 PER30 PER40 PER50 PER60 PER70 PER80 PER90 <DEFAULT> (default value: PER50) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter indicates the coding scheme to be used when the packet transfer starts. The value is used only if no other information about optimum coding scheme is available. Validity range: initialCodingScheme CS1 CS2 CS3 CS4 <DEFAULT> (default value: CS2) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter indicates the coding scheme to be used when the packet transfer starts. The value is used only if no other information about optimum coding scheme is available. Validity range: initialCodingSchemeTD CS1 CS2 <DEFAULT> (default value: CS1) Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD 1594 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller INIMCSDL INIMODETD ININHO INITLEV This parameter suggests the MCS to be used in an EDGE TBF if no other information about that MS in that BVC is available. This parameter can be used if MS is a GMSK MS, Incremental Redundancy is not usable in the BVC and no other information is available about that MS. Validity range: initialMcsDownlink MCS1 MCS2 MCS3 MCS4 MCS5 MCS6 MCS7 MCS8 MCS9 <NULL> (default value: MCS9) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter defines the Mode of coding scheme to be used in the cell. Validity range: initialModeTD Mode1 Mode2 (default value: Mode1) Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD The attribute enables/disables the intercell handover from inner to inner area in sectorized concentric cells Validity range: enableInnerInnerHo FALSE, TRUE (default value: FALSE) Contained in the following commands: GET HAND, SET HAND This attribute defines the initialization level. Each level provides correction actions and should be applied when hardware and software faults cause a system to have an unstable or non correct behaviour. The following levels are provided: BU_ACTIVE The initialization is performed at the highest level; it is used by the system when starting a bring_up. FULL The initialization involves the processor memory and the hardware. It forces the release of all connections. TASK_PRIME The lower level initializations involve all connections. A30808-X3247-L230-3-7619 1595 Commands Base Station Controller CML:BSC INSTANCE INTAVEPR INTCLASS Prime/Start activities which are restarted. Processor memory and hardware are partially initialized. Connections which are in steady state (talking subscribers) are preserved. Validity range: initLevel BU_ACTIVE FULL , TASK_PRIME Contained in the following commands: SYSINIT SYSINIT This attribute specifies the instance of the Network Element (TRAU or BTSE) which the upload of the log file is related to. Validity range: instance 0..199 for UPLBTSLOG 0..35 for UPLTRAULOG Contained in the following commands: UPLTRAULOG, UPLBTSTDLOG, UPLBTSLOG This attribute contains two parameters used in averaging the interference levels in the unallocated time slots. averagingPeriod indicates the number of SACCH multiframes over which the values are averaged. interferenceThresholdBoundaries<n> (with <n> from1 to 4) indicates boundary limits of four interference bands for the unallocated time slots. The BSS shall map the averaged interference level measurements into these five bands. Validity range: interferenceAveragingProcess averPeriod 1..31 (default value = 31) intThrBou1 0..62 (default value = 2) intThrBou2 0..62 (default value = 6) intThrBou3 0..62 (default value = 12) intThrBou4 0..62 (default value = 22) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This attribute defines whether the interference classification of idle traffic channels is enabled or disabled. Validity range: enableInterferenceClass FALSE TRUE 1596 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller INTDLAVP INTERCH INTINF INTRACH <DEFAULT> (default value: TRUE) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter specifies the averaging period for DL interference measurements. The averaged values are used at the end of the period to update the priority values, which are needed for the Priority based Admission Control, for all DL timeslots. Validity range: interferenceDLAvePer 1..255 multiframes Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This attribute allows a managing systemto enable or disable inter cell handovers for TCH channels in BTS. Validity range: enableInterCellHo FALSE TRUE (default value: FALSE) Contained in the following commands: GET HAND, SET HAND, GET HANDTD, SET HANDTD This parameter identifies the logic interface towards the alarm detection equipment. Validity range: interfaceInformation low high <DEFAULT> (default value: high) Contained in the following commands: CREATE ENVA, GET ENVA, SET ENVA This attribute allows a managing systemto enable or disable intracell handovers for TCH channels in BTS. The attribute is meaningless when the cell is concentric. Validity range: enableIntraCellHo FALSE, TRUE (default value: FALSE) Contained in the following commands: GET HAND, SET HAND, GET HANDTD, SET HANDTD A30808-X3247-L230-3-7619 1597 Commands Base Station Controller CML:BSC INTTHDL INTTHUL INTULAVP IPADDR IRACHOSDCCH This parameter defines the threshold, which is used to compare the interference measurements reported by the UEs to it. The results of the comparisons are averaged for a certain period, which is deter- mined by another attribute. The averaged value is used to update the priority values, which are needed for Priority based Admission Control, of the DL timeslots. Validity range: interferenceThresDL -115..-25 dBm (1 dBm step size) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter defines the threshold, which is used to compare the interference measurements of the BTSC to it. The results of the comparisons are averaged for a certain period, which is determined by another attribute. The averaged value is used to update the priority values, which are needed for Priority based Admission Control, of the UL timeslots. Validity range: interferenceThresUL -120.0..-57.0 dBm (0.5 dBm step size) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter specifies the averaging period for UL interference measurements. The averaged values are used at the end of the period to update the priority values, which are needed for the Priority based Admission Control, for all UL timeslots. Validity range: interferenceULAvePer 1..255 multiframes Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This attribute represents a well known IP address of an external equipment that should be reached by the BSC using a ping operation. Validity range: ipAddress String 7..15 chars Contained in the following commands: PING IPLI This attribute allows a managing systemto enable or disable intracell handovers for SDCCH channels. Validity range: enableIntraCellHoSdcch FALSE TRUE <NULL> 1598 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller L1CTS L2PV L2WIN L3PS (default value: FALSE) Contained in the following commands: GET HAND, SET HAND It defines the layer 1 dedicated 16kbit/s subchannel used for supervision in case of LOOP configuration. Validity range: layer1ControlTimeslot <DEFAULT> <NULL> Tsl TSL_1..TSL_31 (default value: TSL_1) Ssl SSL_0..SSL_3 NOT_DEFINED (default value: SSL_0) Contained in the following commands: CREATE PCMB, GET PCMB, SET PCMB Protocol variant. Validity range: layer2ProtocolVariant ISO_7776 GENPDN DDNTW (default value: ISO_7776) Contained in the following commands: GET X25A, GET X25D Window size. Validity range: layer2WindowSize 1..7 (default value: 7) Contained in the following commands: CREATE X25A, GET X25A, SET X25A, CREATE X25D, GET X25D, SET X25D Network Layer Packet Size. Validity range: networkLayerPacketSize Packet_128 Packet_256 Packet_512 Packet_1024 Packet_2048 Packet_4096 <DEFAULT> A30808-X3247-L230-3-7619 1599 Commands Base Station Controller CML:BSC L3PV L3WIN LAPDOVLT LAPDPOOL (default value: Packet_2048) Contained in the following commands: CREATE X25A, GET X25A, SET X25A, CREATE X25D, GET X25D, SET X25D Protocol Variant. Validity range: networkLayerProtocolVariant ISO8208VER80 PDN1980 DDN1980 ISO8208VER84 (default value: ISO8208VER84) Contained in the following commands: GET X25A, GET X25D Network Layer Window Size. Validity range: l3win 1..7 <DEFAULT> (default value: 7) Contained in the following commands: CREATE X25A, GET X25A, SET X25A, CREATE X25D, GET X25D, SET X25D This parameter defines the overload indication period. Validity range: lapdOverloadTimer 1..60 s <NULL> (default value: 10) Contained in the following commands: CREATE BTSM, GET BTSM, SET BTSM, CREATE BTSMTD, GET BTSMTD, SET BTSMTD If the PPXLs are used, this attribute assumes the meaning of "primary PPXL" (i.e. the PPXL where the LAPD must work if both PPXLs are in service). If case of NTWSN16 the LAPDPOOL value does not have any relationship with the instance of the physical PPLDs equipped. The operator, by means of this attribute, can define a group of LAPDs managed by the same PPLD. If the operator does not set the attribute the value is assigned by the BSC. Validity range: 1600 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller LCBM0 LCBM1 lapdPool 0..13 Contained in the following commands: CREATE LPDLM, GET LPDLM, SET LPDLM, CREATE LPDLS, GET LPDLS, SET LPDLS This attribute specifies the handling and the contents of the Local Cell Broadcast Message. Validity range: localCellBroadcastMessage0 <DEFAULT> <NULL> MSGID 0..65534 PAGE 1..92 characters string REPRATE SEC_0002 SEC_0010 SEC_0030 SEC_0060 SEC_0090 SEC_0120 SEC_0150 SEC_0180 SEC_0240 SEC_0360 SEC_0480 SEC_0960 SEC_1920 SCHEME GERMAN ENGLISH ITALIAN FRENCH SPANISH DUTCH SWEDISH DANISH PORTUGUESE FINNISH NORWEGIAN GREEK TURKISH UNSPECIFIED (default value: <NULL>) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD This attribute specifies the handling and the contents of the Local Cell Broadcast Message. Validity range: localCellBroadcastMessage1 <DEFAULT> <NULL> MSGID 0..65534 PAGE 1..92 characters string REPRATE SEC_0002 SEC_0010 SEC_0030 SEC_0060 SEC_0090 SEC_0120 SEC_0150 SEC_0180 SEC_0240 SEC_0360 SEC_0480 SEC_0960 SEC_1920 SCHEME GERMAN ENGLISH ITALIAN FRENCH A30808-X3247-L230-3-7619 1601 Commands Base Station Controller CML:BSC LCBM2 LCBM3 SPANISH DUTCH SWEDISH DANISH PORTUGUESE FINNISH NORWEGIAN GREEK TURKISH UNSPECIFIED (default value: <NULL>) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD This attribute specifies the handling and the contents of the Local Cell Broadcast Message. Validity range: localCellBroadcastMessage2 <DEFAULT> <NULL> MSGID 0..65534 PAGE 1..92 characters string REPRATE SEC_0002 SEC_0010 SEC_0030 SEC_0060 SEC_0090 SEC_0120 SEC_0150 SEC_0180 SEC_0240 SEC_0360 SEC_0480 SEC_0960 SEC_1920 SCHEME GERMAN ENGLISH ITALIAN FRENCH SPANISH DUTCH SWEDISH DANISH PORTUGUESE FINNISH NORWEGIAN GREEK TURKISH UNSPECIFIED (default value: <NULL>) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD This attribute specifies the handling and the contents of the Local Cell Broadcast Message. Validity range: localCellBroadcastMessage3 <DEFAULT> <NULL> MSGID 0..65534 PAGE 1..92 characters string REPRATE SEC_0002 SEC_0010 SEC_0030 SEC_0060 SEC_0090 SEC_0120 SEC_0150 SEC_0180 1602 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller LCN2WC LCNIOC LCNOOC SEC_0240 SEC_0360 SEC_0480 SEC_0960 SEC_1920 SCHEME GERMAN ENGLISH ITALIAN FRENCH SPANISH DUTCH SWEDISH DANISH PORTUGUESE FINNISH NORWEGIAN GREEK TURKISH UNSPECIFIED (default value: <NULL>) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD LCN of 1st 2 Way Channels. Validity range: lcn2wc 0..4095 <DEFAULT> (default value: 1) Contained in the following commands: CREATE X25A, GET X25A, SET X25A, CREATE X25D, GET X25D, SET X25D This read-only parameter defines the LCN of first incoming only channels, included in the X25A and X25D configuration message (IXLT restart). Validity range: lcnOf1stIncomingOnly 0..4095 (default value: 0) Contained in the following commands: GET X25A, GET X25D This read-only parameter defines the LCN of first outgoing only channels, included in the X25A and X25D configuration message (IXLT restart). Validity range: lcnOf1stOutgoingOnly 0..4095 (default value: 0) Contained in the following commands: GET X25A, GET X25D A30808-X3247-L230-3-7619 1603 Commands Base Station Controller CML:BSC LCSMONTH LCSNSSC LEND LEVHOM The LCSMONTH (LCS Monitor Thresholds) parameter indicates the A-Int Monitor Thresholds for SS7 channels. The threshold is the percentage between out of service SS7S on equipped SS7S; that is: LCSMONTH = (SS7S out of service/SS7S equipped)*100). The threshold values can be assigned only when the flag attribute is set to enabled. Validity range: minor disabled 0..0 enabled 1..100 major disabled 0..0 enabled 1..100 critical disabled 0..0 enabled 1..100 Contained in the following commands: GET BSC, SET BSC This parameter allows to choose the location service type (NSS centric / BSS centric) supported by BSC. If this parameter is set at TRUE, the BSC supports the NSS centric solution and all the BSS requests are rejected, on the contrary if it is set at FALSE the BSC support the BSS centric request and the NSS centric are rejected. Validity range: lcsNssCentric TRUE FALSE (default value: FALSE) Contained in the following commands: SET BSC, GET BSC, This attribute identifies the number of BYTE, WORD or DWORD to read. Validity range: lengthData 1..128 Contained in the following commands: MEMDUMP BSC This parameter represents a threshold to guarantee a handover to a target cell with a higher level than the serving cell, without altering the behaviour of the other handover types. The set value ranges from -63 dB to +63 dB. (1 dB step size). Validity range: levelHOMargin 0..126 <NULL> (default value: 69 [6 dB]) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC 1604 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller LEVONC LFID LINKTYPE LKSET LNKA The attribute defines the level offset that is added to the minimum receive level of an adjacent cell to become a target cell in case the ranking method 1 is specified in the hierarchicalCellRankFlag (object HAND). Validity range: levelOffsetNCell 0..63 dB <DEFAULT> (default value: 0) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC This attribute defines the list of the file names that have to be compressed. It consists of a list of 60 items; for each item, the field attribute has to be set. Validity range: listOfFileIds 1..60 items max list (LFID1&LFID2&......) For each item LFID<n> the following field can be set: field: 1..13 characters string Contained in the following commands: FILECOM FILEHANDLER This parameter indicates the type of the physical link used. Validity range: linkType X25A X25D IPLI <DEFAULT> (default value:X25D) Contained in the following commands: CREATE CBCL, GET CBCL, CREATE OMAL, GET OMAL This parameter defines the linkset number of SS7L link. Validity range: linkSet 0..1 (default value: 0) Contained in the following commands: CREATE SS7L, GET SS7L Circuit on the selected PPCCcard. This parameter is addressed by the PPCC number and circuit number. Validity range: <NULL> A30808-X3247-L230-3-7619 1605 Commands Base Station Controller CML:BSC LOGTYPE LOTERCH LOTRACH LOWBER PPCCN 0..1 circn 0..3 Contained in the following commands: CREATE SS7L, GET SS7L This parameter defines the log file type; two type of log file are available: command responses and events log file. Validity range: Logtype CMDRSPLOG EVTLOG Contained in the following commands: UPLPRLOG FILEHANDLER This attribute allows a managing system to enable or disable BSC controlled inter cell handovers. The attribute takes the following values: TRUE - BSC controlled inter cell handovers are allowed, FALSE- BSCcontrolled inter cell handovers are not allowed (the inter cell handovers are managed by MSC). Validity range: enablelocalInterCellHo FALSE TRUE (default value: TRUE) Contained in the following commands: GET HAND, SET HAND, GET HANDTD, SET HANDTD This attribute allows a managing system to enable or disable BSC controlled intracell handovers. If the attribute values TRUE the BSC controlled intracell handovers are allowed, if it values FALSEthe BSC controlled intracell handovers are not allowed (the intracell handovers are managed by MSC). Note that in case of Extended and Concentric cells the Intracell Handover is always managed by the BSC and so this attribute value is meaningless. Validity range: enableLocalIntraCellHo FALSE TRUE (default value: TRUE) Contained in the following commands: GET HAND, SET HAND, GET HANDTD, SET HANDTD This parameter defines the Lower Bit Error Rate value. Validity range: lowerBitErrorRate E10_3 E10_4 E10_5 E10_6 E10_7 E10_8 1606 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller LOWTLEVD LOWTLEVU LOWTQUAD E10_9 <DEFAULT> (default value: E10_3) Contained in the following commands: CREATE PCMA, GET PCMA, CREATE PCMB, GET PCMB, SET PCMB, CREATE PCMG, GET PCMG, SET PCMG, CREATE PCMS, GET PCMS, SET PCMS This attribute defines the lower threshold of the received signal level on downlink for power increase. Validity range: pcLowerThresholdLevDL 0..63 dBr (default value: 25) For the values make references to Appendix B: Group 2. Contained in the following commands: GET PWRC, SET PWRC This attribute defines the lower threshold of the received signal level on uplink for power increase. Validity range: pcLowerThresholdLevUL 0..63 dBr (default value: 25) For the values make references to Appendix B: Group 2. Contained in the following commands: GET PWRC, SET PWRC This attribute defines the lower threshold of the received signal quality on downlink for power increase. Validity range: pcLowerThresholdQualDL 0..7 (default value: 4) For the values make references to Appendix B: Group 3. Contained in the following commands: GET PWRC, SET PWRC A30808-X3247-L230-3-7619 1607 Commands Base Station Controller CML:BSC LOWTQUAMRDL LOWTQUAMRUL LOWTQUAU This parameter determines the lower power control downlink quality threshold for AMR calls. In case of an AMR call LOWTQUAMRDL eclipses the threshold LOWTQUAD, i.e. for AMR calls the power control algorithmincreases the DL transmit power if the quality drops below the threshold determined by LOWTQUAMRDL. As LOWTQUAMRDL is entered in C/I values, but the MS reports the serving cell quality in form of RXQUAL values, the BTS performs an internal mapping of RXQUAL to C/I values prior to the power control decision. Validity range: pcLowerThresQualAMRDL 0..30 (1 dB step size) <NULL> (default value: 10 dB) Contained in the following commands: GET PWRC, SET PWRC This parameter determines the lower power control uplink quality threshold for AMR calls. In case of an AMR call LOWTQUAMRUL eclipses the threshold LOWTQUAU, i.e. for AMR calls the power control algorithmincreases the UL transmit power if the quality drops below the threshold determined by LOWTQUAMRUL. As LOWTQUAMRUL is entered in C/I values, but the BTS measures the serving cell quality in form of RXQUAL values, the BTS performs an internal mapping of RXQUAL to C/I values prior to the power control decision. Validity range: pcLowerThresQualAMRUL 0..30 (1 dB step size) <NULL> (default value: 10 dB) Contained in the following commands: GET PWRC, SET PWRC This attribute defines the lower threshold for the received signal quality on uplink for power increase. Validity range: pcLowerThresholdQualUL 0..7 (default value: 4) For the values make references to Appendix B: Group 3. Contained in the following commands: GET PWRC, SET PWRC 1608 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller LPDLMN LPDLMTDN LPDLMSAT LREDUNEQ This parameter indicates the "primary" position (pcmb number and TS LAPD number) of the LPDLR links. This "primary" position identifies the physical LAPD link (LPDLM) which the LPDLR link created is mapped to. Validity range: lapdmNumber 0..7 Contained in the following commands: CREATE TRX, GET TRX This parameter indicates the superordinate LPDLMTD (Primary Posi- tion). Validity range: lapdmtdNumber 0..7 Contained in the following commands: CREATE TRXTD, GET TRXTD This attribute indicates whether the LAPD link on the Abis interface is satellited or terrestrial. Validity range: lapdmLinkSatellited FALSE TRUE <DEFAULT> (default value: FALSE) Contained in the following commands: CREATE BTSM, GET BTSM, CREATE BTSMTD, GET BTSMTD This attribute assumes three values depending on the three following PCM line configurations: - only trunk A is equipped (star or multidrop configuration) - only trunk B is equipped (star or multidrop configuration) - both trunk A and B are equipped (loop configuration) Validity range: lineRedundancyEquipped SIMPLEXA SIMPLEXB, DUPLEX The SET PCMB and SET PCMS commands change the parameter only to DUPLEX. Contained in the following commands: CREATE PCMB, GET PCMB, SET PCMB, CREATE PCMS, GET PCMS, SET PCMS A30808-X3247-L230-3-7619 1609 Commands Base Station Controller CML:BSC LSLOTIME LSULOTIME This read-only parameter is the date of the last LOCK command. It consists of the following fields: Day, Month, Year, Hour and Min. Validity range: lastLockTime Day 1..31 Month Jan, Feb, Mar, Apr, May, Jun, Jul, Aug, Sep, Oct, Nov, Dec Year 1992..2099 Hour 0..23 Min 0..59 Contained in the following commands: GET SCANAIRTSTD, GET SCANBSC, GET SCANBTS, GET SCANBTSABISTD, GET SCANBTSE, GET SCANBTSIHO, GET SCANBTSM, GETSCANBTSMTD, GET SCANBTSOHOI, GET SCANBTSOHON, GET SCANBTSOHOS, GET SCANBTSTD, GET SCANBTSTDIHDO, GET SCANBTSTDOHDOI, GET SCANBTSTDOHON, GET SCANCHAN, GET SCANCTRX, GET SCANFBTSM, GET SCANGPRS, GET SCANGPRSTD, GET SCANSS7L, GET SCANTRX, GET SCANTRXABISTD, GET SCANTRXTD This read-only parameter is the date of the last LOCK command. It consists of the following fields: Day, Month, Year, Hour and Min. Validity range: lastUnlockTime Day 1..31 Month Jan, Feb, Mar, Apr, May, Jun, Jul, Aug, Sep, Oct, Nov, Dec Year 1992..2099 Hour 0..23 Min 0..59 Contained in the following commands: GET SCANAIRTSTD, GET SCANBSC, GET SCANBTS, GET SCANBTSABISTD, GET SCANBTSE, GET SCANBTSIHO, GET SCANBTSM, GETSCANBTSMTD, GET SCANBTSOHOI, GET SCANBTSOHON, GET SCANBTSOHOS, GET SCANBTSTD, GET SCANBTSTDIHDO, GET SCANBTSTDOHDOI, GET SCANBTSTDOHON, GET SCANCHAN, GET SCANCTRX, GET SCANFBTSM, GET SCANGPRS, GET SCANGPRSTD, GET SCANSS7L, GET SCANTRX, GET SCANTRXABISTD, GET SCANTRXTD 1610 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller LSUPDTIME M2T1 M2T2 M2T3 This read-only parameter is the date of the last configuration command (CREATE or SET command). It consists of the following fields: Day, Month, Year, Hour and Min. Validity range: lastUpdTime Day 1..31 Month Jan, Feb, Mar, Apr, May, Jun, Jul, Aug, Sep, Oct, Nov, Dec Year 1992..2099 Hour 0..23 Min 0..59 Contained in the following commands: GET CTRSCHED, GET SCANAIRTSTD, GET SCANBSC, GET SCANBTS, GET SCANBTSABISTD, GET SCANBTSE, GET SCANBTSIHO, GET SCANBTSM, GETSCANBTSMTD, GET SCANBTSOHOI, GET SCANBTSOHON, GET SCANBT- SOHOS, GET SCANBTSTD, GET SCANBTSTDIHDO, GET SCANBTSTDOHDOI, GET SCANBTSTDOHON, GET SCANCHAN, GET SCANCTRX, GET SCANFBTSM, GET SCANGPRS, GET SCANGPRSTD, GET SCANSS7L, GET SCANTRX ,GET SCANTRXABISTD, GET SCANTRXTD "Alignment ready" timer Validity range: mtl2Timer1 400-500 hundreds of milliseconds for CCITT 129-160 hundreds of milliseconds for ANSI (default value: 450 for CCITT and 140 for ANSI) Contained in the following commands: CREATE OPC, GET OPC, SET OPC "Not aligned" timer. Validity range: mtl2Timer2 50-1500 hundreds of milliseconds for CCITT 50-300 hundreds of milliseconds for ANSI (default value: 1000 for CCITT and 120 for ANSI) Contained in the following commands: CREATE OPC, GET OPC, SET OPC "Aligned" timer Validity range: mtl2Timer3 10-15 hundreds of milliseconds for CCITT A30808-X3247-L230-3-7619 1611 Commands Base Station Controller CML:BSC M2T4E M2T4N M2T5 M2T6 50-140 hundreds of milliseconds for ANSI (default value: 10 for CCITT and 120 for ANSI) Contained in the following commands: CREATE OPC, GET OPC, SET OPC Emergency proving period timer Validity range: mtl2Timer4E 4-5 hundreds of milliseconds for CCITT 4-7 hundreds of milliseconds for ANSI (default value: 5 for CCITT and 6 for ANSI) Contained in the following commands: CREATE OPC, GET OPC, SET OPC Normal proving period timer. Validity range: mtl2Timer4N 75-95 hundreds of milliseconds for CCITT 15-30 hundreds of milliseconds for ANSI (default value: 80 for CCITT and 24 for ANSI) Contained in the following commands: CREATE OPC, GET OPC, SET OPC SIB Sending timer. Validity range: mtl2Timer5 1..2 (100 ms step size) (default value: 1) Contained in the following commands: CREATE OPC, GET OPC, SET OPC Remote congestion timer. Validity range: mtl2Timer6 30-60 hundreds of milliseconds for CCITT 10-60 hundreds of milliseconds for ANSI (default value: 60 for CCITT and 50 for ANSI) Contained in the following commands: CREATE OPC, GET OPC, SET OPC 1612 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller M2T7 M3T1 M3T1TM M3T2 M3T2TM M3T3 Excessive delay of acknowledgement timer Validity range: mtl2Timer7 5-20 hundreds of milliseconds (default value: 20 for CCITT and 10 for ANSI) Contained in the following commands: CREATE OPC, GET OPC, SET OPC Delay to avoid the out-of-sequence of messages on CO. Validity range: mtl3Timer1 5-12 hundreds of milliseconds (default value: 9) Contained in the following commands: CREATE OPC, GET OPC, SET OPC Supervision timer for signalling link test acknowledgment message. Validity range: mtl3Timert1tm 40-120 hundreds of milliseconds (default value:100 for CCITT and 50 for ANSI) Contained in the following commands: CREATE OPC, GET OPC, SET OPC Wait for CO acknowledgement. Validity range: mtl3Timer2 7-20 hundreds of milliseconds (default value: 13 for CCITT and 14 for ANSI) Contained in the following commands: CREATE OPC, GET OPC, SET OPC Interval timer for sending periodic link test message. Validity range: mtl3Timert2tm 6-18 unit of 5 seconds (default value:6 for CCITT and 17 for ANSI) Contained in the following commands: CREATE OPC, GET OPC, SET OPC Diversion delay controlled by a timer. Validity range: mtl3Timer3 5-12 hundreds of milliseconds A30808-X3247-L230-3-7619 1613 Commands Base Station Controller CML:BSC M3T4 M3T5 M3T10 M3T12 M3T13 (default value: 9) Contained in the following commands: CREATE OPC, GET OPC, SET OPC Wait for CB acknowledgement first attempt. Validity range: mtl3Timer4 5-12 hundreds of milliseconds (default value: 8) Contained in the following commands: CREATE OPC, GET OPC, SET OPC Wait for CB acknowledgement second attempt. Validity range: mtl3Timer5 5..12 (100 ms step size) <DEFAULT> (default value: 8) Contained in the following commands: CREATE OPC, GET OPC, SET OPC This attribute represents the waiting time to repeat the route set test message. Validity range: mtl3Timer10 60..120 (0,5 s step size) <DEFAULT> (default value: 60) Contained in the following commands: CREATE OPC, GET OPC, SET OPC Wait for uninhibit acknowledgement. Validity range: mtl3Timer12 8..15 (100 ms step size) <DEFAULT> (default value: 12) Contained in the following commands: CREATE OPC, GET OPC, SET OPC Wait to force uninhibit. Validity range: mtl3Timer13 8..15 (100 ms step size) <DEFAULT> 1614 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller M3T14 M3T17 M3T19 M3T22OR20 M3T23OR21 (default value: 8) Contained in the following commands: CREATE OPC, GET OPC, SET OPC Wait for inhibit acknowledgement. Validity range: mtl3Timer14 20..30 (100 ms step size) <DEFAULT> (default value: 20) Contained in the following commands: CREATE OPC, GET OPC, SET OPC Delay to avoid oscillation of the initial alignment. Validity range: mtl3Timer17 8..15 (100 ms step size) <DEFAULT> (default value: 10) Contained in the following commands: CREATE OPC, GET OPC, SET OPC Failed link craft referral timer. Validity range: mtl3Timer19 12..120 (5 s unit) <DEFAULT> (default value: 12 [60 s]) Contained in the following commands: CREATE OPC, GET OPC, SET OPC Local inhibit test timer. Validity range: mtl3Timer22or20 36-72 unit of 5 seconds for CCITT 18-24 unit of 5 seconds for ANSI (default value: 36 for CCITT and 22 for ANSI) Contained in the following commands: CREATE OPC, GET OPC, SET OPC Remote inhibit test timer. Validity range: mtl3Timer23or21 36-72 unit of 5 seconds for CCITT 18-24 unit of 5 seconds for ANSI A30808-X3247-L230-3-7619 1615 Commands Base Station Controller CML:BSC MACONN MACRADIUS MADGRLV MAFIRACHO (default value: 36 for CCITT and 22 for ANSI) Contained in the following commands: CREATE OPC, GET OPC, SET OPC This attribute gives the maximum number of connections traced in this particular cell. Validity range: maxConnectionNumber 1-16 Contained in the following commands: CREATE CTRSCHED, GET CTRSCHED, SET CTRSCHED This parameter defines the radius of the cell in units of 125 metres. The correspondence between the field number and the cell radius in meters is: 0 125 m 1 250 m .... 60 7625 m (default value) .... 254 31875 m 255 32000 m Validity range: maxCellRadius 0..255 <DEFAULT> (default value: 60) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD. This attribute indicates the Maximum AIUR (Air Interface User Rate) Downgrade Level for NT data calls from the initial request (is meaningless if ENHSCSD = FALSE). Validity range: maxDowngradeLevel 0..3 (default value: 2) Contained in the following commands: GET BSC, SET BSC This attribute indicates the Maximum Number of Forced Intracell HO procedures to be executed (is meaningless if ENHSCSD = FALSE or ENFOIAHO = FALSE). Validity range: maxForcedIntraCellHo 1..3 1616 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller MAIO MAIRACHO MAIRACHOTD MANBFEVTX (default value: 2) Contained in the following commands: GET BSC, SET BSC Offset of the Mobile Allocation Index used in the generation of the frequency hopping sequence. Validity range: maio 0..63 <DEFAULT> (default value: 0) Contained in the following commands: CREATE CHAN, GET CHAN, SET CHAN This attribute specifies both the maximum number of consecutive successful Quality IntraBSCHandovers and the maximumnumber of consecutive successful compression/decompression AMR Quality IntraBSC Handovers that are permitted in the same BTS for a single connection: the IntraBSC cell Handover is suspended when the threshold MAIRACHO + 1 is reached. In case of normal call, the internal counter is increased for each successful Quality Handover. In case of AMR call, the internal counter is increased for each couple of compression/decompression Handovers, i.e. FR -> HR and HR -> FR. If an AMR call is set up on a HR channel the first decompression handover (HR -> FR) is not taken into account. Validity range: maxIntraCellHandover 1..15 (default value: 2) Contained in the following commands: GET HAND, SET HAND This attribute specifies the maximum number of consecutive successful Quality IntraBSC Handovers. Validity range: maxIntraCellHandoverTD 1..15 <DEFAULT> (default value: 10) Contained in the following commands: GET HANDTD, SET HANDTD This parameter defines the maximum number of BF Eigenvalues used for TX BF. Validity range: maxNumBFEVTX 1..8 (1 step size) <DEFAULT> A30808-X3247-L230-3-7619 1617 Commands Base Station Controller CML:BSC MANOUSRTS MARINTDL MARACHTRANS MARXPP (default value: 3) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter defines the maximumnumber of user per timeslot (UL and DL), thus determining the (minimum) available window length for channel selection and estimation on all DL TSs assigned in the cell. Validity range: maxNofUsersPerTS N_08 N_12 N_16 <DEFAULT> (defaul value: N_16) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter is an absolute logatithmic value needed only in BSC to calculate the initial power level; this value increase/decrease the initial power level according to the quality of radio downlink path. Validity range: marIntDL 0..12 dB (0.5 dB step size) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD. This parameter definesthe maximum number of CHANNEL REQUEST message transmissions during an access procedure. Validity range: maxRachTrans MAX_1_RETRANSM MAX_2_RETRANSM MAX_4_RETRANSM MAX_7_RETRANSM <DEFAULT> (default value: MAX_1_RETRANSM) Contained in the following commands: This parameter defines the maximal received power (dBm) per code in case that the code is of a smaller spreading factor than 16. This power can be 16/Q(Q is spreading factor used) higher in order to compensate party effect. Validity range: maxRXPowerParty -110..-47 dBm (1 dBm step size) <DEFAULT> 1618 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller MASCLOGFS MASONLYC MASY1RETS MATXDLTSX (default value: -80 dBm) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This attributes indicates the maximum size (in Mbytes) for each SCAN log file. Validity range: maxScannerLogFileSize 1..6 (default value: 3) Contained in the following commands: GET BSC, SET BSC This parameter defines the maximum percentage of SF16 codes (both in Uplink and Downlink direction) that can be allocated to signalling only services. Validity range: maxSignallingonlyCodes 5..100 Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD. This parameter defines the maximum number of SYNC1 burst retransmission during an access procedure. Validity range: maxSync1Retrans MAX_1_RETRANSM MAX_2_RETRANSM MAX_4_RETRANSM MAX_7_RETRANSM <DEFAULT> (default value: MAX_1_RETRANSM) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter defines the maximal transmit power in each timeslot except the timeslot in which PCCPCH is located. Validity range: numberOfCarriers 1..3 maxTXDLTSX 0..30 Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD A30808-X3247-L230-3-7619 1619 Commands Base Station Controller CML:BSC MATXULTSX MAXFAILHO MAXFAILHOTD MAXNCELL MAXRETR This parameter defines the maximal transmit power (dBm) of UE in each individual timeslot. Validity range: maxTXULTSX -47..34 dBm (1 dBm step size) <DEFAULT> (default value: 33 dBm) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD. This attribute specifies the maximum number of consecutive failures of Intra and Inter BSC Handovers permitted in the same BTS for a single connection. Validity range: maxFailHo 1..15 (default value: 2) Contained in the following commands: GET HAND, SET HAND This attribute specifies the maximum number of consecutive failures of Intra and Inter BSC Handovers permitted in the same TD-SCDMA cell for a single connection. Validity range: maxFailHoTD 1..15 <DEFAULT> (default value: 2) Contained in the following commands: GET HANDTD, SET HANDTD It is the max number of adjacent cells on which the handover can be performed. Validity range: maxNCell 1..16 (default value: 1) Contained in the following commands: GET BSC,SET BSC This parameter defines the maximum number of retransmissions a MS can perform on the RACH. Validity range: maxNumberRetransmission One Two Four Seven <DEFAULT> 1620 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller MEASLST MEASOBJLST (default value: Four) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter, used by all the scanner types, allows the user to define the list of the measures to be executed by the scanner. It consists of two fields. The first field can be set to measList or to allMeas value. If measList value is selected, the second field shows the measures list related to the type of the selected scanner and the operator can select one or more measures. If allMeas value is selected, the list of measures disappear (field equal to 0..0) and the complete measure list is executed when the scanner will be activated. For the SCANBTSM object, the list of the measures is only present. Validity range: measureList measList list of all measures allMeas 0..0 For the list of the measures related to the different type of scanner, please refer to the chapter 4 of the manual "Performance Measure- ment Counter". Contained in the following commands: CREATE SCANBSC, GET SCANBSC, SET SCANBSC, CREATE SCANBTS, GET SCANBTS, SET SCANBTS, CREATE SCANBTSE, GET SCANBTSE, SET SCANBTSE, CREATE SCANBTSIHO, GET SCANBTSIHO, SET SCANBTSIHO, CREATE SCANBTSM, GET SCANBTSM, SET SCANBTSM, CREATE SCANBTSOHOI, GET SCANBTSOHOI, SET SCANBTSOHOI, CREATE SCANBTSOHON, GET SCANBTSOHON, SET SCANBTSOHON, CREATE SCANBTSOHOS, SET SCANBTSOHOS, GET SCANCHAN, GET SCANCTRX, CREATE SCANFBTSM, GET SCANFBTSM, SET SCANFBTSM, CREATE SCANGPRS, GET SCANGPRS, SET SCANGPRS, CREATE SCANSS7L, GET SCANSS7L, SET SCANSS7L, CREATE SCANTRX, GET SCANTRX, SET SCANTRX This parameter represents the list of the measures that have to be executed. For the list of all measures related to the different type of scanners, please refer to the chapter 4 of the manual "Performance Measure- ment Counter". Validity range: For SCANAIRTSTD: measObjList 1..10 items and for each item we can define: BtsmTdId 0..363 BtsTdld 0..2 A30808-X3247-L230-3-7619 1621 Commands Base Station Controller CML:BSC TrxTdld 0..2 Airtstdld AirtsT- dList all list 0..6 For SCANBSC: measObjList list of all measures For SCANBTS and SCANGPRS: measObjList MeasList list of all measures ObjList Items: 1..50 BtsmIs: 0..199 BtsId: 0..23 For SCANBTSABISTD: measObjList Items: 1..50 btsmTdId: 0..363 btsTdId: 0..2 For SCANBTSE: measObjList measlst list of all measures objlst Items: 1..50 btsmld: 0..199 btsId: 0..23 For SCANBTSM: measObjList List 1..100 of 0..99 For SCANBTSMTD: measObjList measList list of all measures objList List 1..100 of 0..363 For the SCANBTSIHO object: objectList 1..10 items and for each item we can define: btsld btsmld 0..199 btsld 0..23 btsAdjcList selfAdapting 0..0 origBtsGroup: 1..32 items and for each: btsmld 0..199 btsld 0..23 For SCANBTSOHOI and SCANBTSOHON: measObjList measList list of all measures adjcOhList 1..10 items and for each: btsld btsmId 0..199 btsld 0..23 adjcId selfAdapting 0..0 selectObjects List 1..32 of 0..31 For SCANBTSOHOS: measObjList measList list of all measures objList 1..10 items and for each: btsld btsmId 0..199 1622 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller btsRelId 0..23 adjcList selfAdapting 0..0 selectObjects List 1..32 of 0..31 For SCANBTSTD and SCANGPRSTD: measObjList MeasList list of all measures ObjList Items: 1..50 BtsmTdId: 0..363 BtsTdId: 0..2 For SCANBTSTDIHDO: measObjList measlst list of all measures objlst 1..10 items and for each item we can define: btstdld btsmtdId 0..363 btstdld 0..2 BtstdAdjcList selfAdapting 0..0 origBtstdGroup: 1..16 items and for each: BtsmTdId 0..363 BtsTdId 0..2 For SCANBTSTDOHDOI and SCANBTSTDOHDON: measObjList measList list of all measures objList 1..10 items and for each: btstdld btsmtdId 0..363 btstdld 0..2 BtsTd- AdjList selfAdapting 0..0 selectObjects List 1..32 of 0..31 For SCANCHAN: measObjList 1..10 items and for each item we can define: btsmId 0..199 btsId 0..23 trxId 0..23 chanId allTch 0..0 list Chan0..Chan7 For SCANCTRX/SCANTRX: measObjList 1..25 items and for each item we can define: btsmId 0..199 btsld 0..23 trxld 0..23 For SCANFBTSM: measObjList measList list of all measures ObjList 0..100 items and for each: A30808-X3247-L230-3-7619 1623 Commands Base Station Controller CML:BSC MECNT MEDAFUPE BtsmId 0..199 For SCANSS7L: measObjList measList list of all measures objList List 1..16 of 0..15 For SCANTRXABISTD/SCANTRXTD: measObjList 1..25 items and for each item we can define: BtsmTdId 0..363 BtsTdld 0..2 TrxTdld 0..2 Contained in the following commands: ADD SCANAIRTSTD, REMOVE SCANAIRTSTD, ADD SCANBSC, REMOVE SCANBSC, ADD SCANBTS, REMOVE SCANBTS, ADD SCANBTSABISTD, REMOVESCANBTSABISTD, ADDSCANBTSE, REMOVE SCANBTSE, ADD SCANBTSIHO, REMOVE SCAN- BTSIHO, ADD SCANBTSM, REMOVE SCANBTSM, ADD SCAN- BTSMTD, REMOVE SCANBTSMTD, ADD SCANBTSOHOI, REMOVE SCANBTSOHOI, ADD SCANBTSOHON, REMOVE SCANBTSOHON, ADD SCANBTSOHOS, REMOVE SCANBTSOHOS, ADD SCANBTSTD, REMOVE SCAN- BTSTD, ADD SCANBTSTDIHDO, REMOVE SCANBTSTDIHDO, ADD SCANBTSTDOHDOI, REMOVE SCANBTSTDOHDOI, ADD SCANBTSTDOHDON, REMOVE SCANBTSTDOHDON, ADD SCANCHAN, REMOVE SCANCHAN, ADD SCANCTRX, REMOVE SCANCTRX, ADD SCANFBTSM, REMOVE SCANFBTSM, ADD SCANGPRS, REMOVE SCANGPRS, ADD SCANGPRSTD, REMOVE SCANG- PRSTD, ADD SCANSS7L, REMOVE SCANSS7L, ADD SCANTRX, REMOVE SCANTRX, ADD SCANTRXABISTD, REMOVE SCANT- RXABISTD, ADD SCANTRXTD, REMOVE SCANTRXTD, This parameter specifies the minimum required measurement samples. Validity range: measCount 100..1000 <DEFAULT> (default value: 200) Contained in the following commands: CREATE RFLOOP, GET RFLOOP, SET RFLOOP The attribute defines the period between two upload of measure- ments data. Validity range: measurementDataFileUploadPeri UPPE_0H Periodic upload disabled (default value) UPPE_1H Periodic upload every 1 hour UPPE_2H Periodic upload every 2 hours 1624 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller MEDAFUST MELID MICROCELL MIDLPRI UPPE_3H Periodic upload every 3 hours UPPE_4H Periodic upload every 4 hours UPPE_6H Periodic upload every 6 hours UPPE_8H Periodic upload every 8 hours UPPE_12H Periodic upload every 12 hours UPPE_24H Periodic upload every 24 hours Contained in the following commands: GET BSC, SET BSC The attribute defines the start time (hour:minute) for measurements data file upload. Validity range: uploadStartHour 0-23 (default value: 0) uploadStartMin 0-59 (default value: 0) Contained in the following commands: GET BSC, SET BSC This parameter defines the name in the BSS. Validity range: managedElementId 0..47 Contained in the following commands: GET MEL, SET MEL This parameter determines whether the adjacent cell is regarded as a microcell. Only if this parameter is set at TRUE the speed sensitive handover algorithm will be in effect for this neighbour cell. Precondition: the database flag for speed sensitive handover is set at enabled (parameter DPBGTHO = TRUE in SET HAND command). Validity range: microcell TRUE, FALSE, <DEFAULT> (default value: FALSE) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC, CREATE ADJC3G, GET ADJC3G, SET ADJC3G This parameter specifies minimum priority value for an DL radio channel available for allocation; it is used in Priority Based admission control. Validity range: minDLPriority 0..100 (default value: 25) A30808-X3247-L230-3-7619 1625 Commands Base Station Controller CML:BSC MIDLPRIHO MINCCNT MIULPRI MIULPRIHO <DEFAULT> Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter defines the minimum priority value for a DL radio channel available for allocation in case of HO; it is used in Priority Based admission control. Validity range: minDLPriorityHO 0..100 <DEFAULT> (default value: 25) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This attribute specifies the minimum required call count. Validity range: minCallCount 20..250 <DEFAULT> (default value: 50) Contained in the following commands: CREATE RFLOOP, GET RFLOOP, SET RFLOOP This parameter specifies the minimum priority value for an UL radio channel available for allocation; it is used in Priority Based admission control. Validity range: minULPriority 0..100 <DEFAULT> (default value: 25) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter specifies minimum priority value for an UL radio channel available for allocation in case of HO; it is used in Priority Based admission control. Validity range: minULPriorityHO 0..100 <DEFAULT> (default value: 25) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD 1626 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller MNTBMASK MOBALLOC MODE MODLUPDMIPER The command allows to set 30 bits (bit0..bit29), however, only some of themcan be really modified by command. Several bits of the Main- tenance bit mask are fixed to '0' or '1' and cannot be changed. NOTE: Bit10 of MNTBMASK attribute is used to enable/disable Delayed TBF Release during Mobility Management (MM) proce- dures. Bit10 set to 0 (default value) corresponds to Delayed TBF Release disabled during MMprocedures; Bit10 set to 1 corresponds to Delayed TBF Release enabled during MM procedures. Validity range: maintenanceBitMask Bit0, Bit1,..,Bit28, Bit29, Null <DEFAULT> Contained in the following commands: GET BSC, SET BSC A list of absolute frequencies used in hopping sequence: 16 frequen- cies at max (16 for BBHOP and 15 for SYNHOP). Validity range: mobileAllocation BCCHFREQ CALLF<nn> where <nn> = 01 to 63 Contained in the following commands: CREATE FHSY, GET FHSY, SET FHSY This attribute can assume two values: FORCED and UNFORCED. If the FORCED value is set, the files already present on the NEY flash EPROM are overwritten otherwise they are not. Validity range: mode FORCED UNFORCED (default value: UNFORCED) Contained in the following commands: NEDOWNLOAD NEYESUSW This parameter it defines the minimum periodicity for the ISCP Measurements on Demand list updating. Validity range: MoDListUpdatingMinPeri- odicity 10..255 <DEFAULT> (default value: 20) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD A30808-X3247-L230-3-7619 1627 Commands Base Station Controller CML:BSC MOEC MORT MPCCCOPY MSBHIPER The attribute specifies whether a TRX belongs to the emergency configuration or not. If this feature is used, the value TRUE should be used at least for the BCCH-TRX. Validity range: memberOfEmergencyConfig TRUE FALSE <DEFAULT> (default value: TRUE) Contained in the following commands: CREATE TRX, GET TRX, SET TRX This parameter defines the hardware unit to be diagnosed. Validity range: mOTs pathname (mnemonic of all the objects that can be tested). The following objects can be tested: DISK DK40 EPWR IXLT LICD LICDS MEMT MPCC NTW PPCC PPCU PPLD PPXL PPXU PWRD TDPC Contained in the following commands: PERFTEST BSCE, STOPTEST BSCE, GET BSCETEST This parameter specifies from which MPCC board (MPCC:0 or MPCC:1) the ping towards an external network element is executed. Validity range: mpccCopy MPCC_0 MPCC_1 Contained in the following commands: PING IPLI If MS Bucket Level is greater than MSBHIPER * Bucket Size PCU then Bucket Congestion is started. Validity range: msBucketHighPercentage PER50 PER60 PER70 PER80 PER90 <DEFAULT> (default value: PER70) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF 1628 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller MSBLPER MSBMAPER MSBSPPER If BVC Bucket Level is lower than MSBLPER * Bucket Size PCU then Bucket Congestion is finished. Validity range: msBucketLowPercentage PER10 PER20 PER30 PER40 PER50 PER60 PER70 PER80 <DEFAULT> (default value: PER60) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute reduces the value of Bmax automatically computed by BSC. BSC criterion is: (C + 1 sec.) * Rmax, where C is the timer reported in GSM 08.18 recommendation and Rmax is the maximum rate assigned to BVC. Validity range: msBucketMaxPercentage PER010 PER020 PER030 PER040 PER050 PER060 PER070 PER080 PER090 PER100 PER110 PER120 PER130 PER140 PER150 PER160 PER170 PER180 PER190 PER200 <DEFAULT> (default value: PER100) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute assigns the value of Bucket Size PCU as percentage of Bmax (twice and so on). Validity range: msBucketSizePcuPercentage PER100 PER110 PER120 PER130 PER140 PER150 PER160 PER170 PER180 PER190 PER200 <DEFAULT> (default value: PER200) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF A30808-X3247-L230-3-7619 1629 Commands Base Station Controller CML:BSC MSCOVLH MSCPERTFLAG MSCPOOL MSCSPC This attribute allows a managing systemto enable or disable the MSC Overload Handling by BSC. Validity range: mscOvlHand FALSE, TRUE (default value: TRUE) Contained in the following commands: GET BSC, SET BSC This attribute represents the flag to enable the periodic test towards SMLC (SLT procedure). Validity range: mscPeriocTestFlag TRUE FALSE <DEFAULT> (default value: TRUE) Contained in the following commands: CREATE OPC, GET OPC,SET OPC This attribute indicates whether the connected MSC is able to manage the pooling feature or not. Validity range: mscPooling FALSE TRUE (default value: FALSE) Contained in the following commands: GET BSC, SET BSC This attribute identifies the destination system (MSC). It consists of three fields: networkClusterMember, networkCluster and networkIdentifier; the first two fields are mandatory while the third field is optional. Validity range: mscSignallingPointCode networkClusterMember 0..255 0-255 for CCITT 1-255 for ANSI networkCluster 0..255 0-63 for CCITT 0-255 for ANSI networkIdentifier 1..254 1-254 for ANSI NO_CONFIG for CCITT Contained in the following commands: CREATE OPC, GET OPC, SET OPC 1630 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller MSCV MSTXPMAXCH MSTXPMAXDCS It is the identifier of the MSC version. Validity range: mscVersion PHASE1: it indicates a Phase 1 MSC; PHASE2: it indicates a Phase 2 MSC supporting neither Current Channel nor Speech Version IES; PHASE2CC: it indicates a Phase 2 MSC supportingtheCurrent Channel IE; PHASE2EFR: it indicates a Phase 2 MSC supporting the Speech Version used IE; PHASE2CCEFR: It indicates a Phase 2 MSC supporting both Current channel and Speech Version used IES. (default value: PHASE1) Contained in the following commands: GET BSC, SET BSC This parameter is used in order to evaluate the path loss criterion parameter C1 or C2 of a cell. It indicates the maximumtransmit power level a MS can use when getting access to the systemon a CCCH of the cell. Validity range: msTxPwrMaxCcch 0..31 (default value: 5 if the SYSID parameter value is BB900, F2ONLY900, EXT900 or GSMR; 0 if the SYSID parameter value is DCS1800 or PCS1900) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter defines the maximumpower level a MScan use in the serving cell for DCS1800. Validity range: msTxPwrMaxDcs 0..15 <NULL> (default value: 0) For the values make references to Appendix B: Group 4. Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE TGTBTS, GET TGTBTS, SET TGTBTS A30808-X3247-L230-3-7619 1631 Commands Base Station Controller CML:BSC MSTXPMAXGSM MSTXPMAXPCS MSTXPMAXUMTS N1 N2 This parameter defines the maximumpower level a MScan use in the serving cell for the GSM 900, GSM850 and GSMR. Validity range: msTxPwrMaxGsm 2..15 <NULL> (default value:5) For the values make references to Appendix B: Group 4. Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE TGTBTS, GET TGTBTS, SET TGTBTS This parameter defines the maximumpower level a MScan use in the serving cell for the PCS 1900. Validity range: msTxPwrMaxPcs 0..31 <NULL> The selecting values are 0..15, 30 and 31. (default value: 0) For the values make references to Appendix B: Group 4. Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE TGTBTS, GET TGTBTS, SET TGTBTS This parameter indicates the maximum transmission power level a MS is allowed to use in the serving cell for the UMTS. Validity range: msTxPwrMaxUmts 0..19 <DEFAULT> (default value: 0) For the values make references to Appendix B: Group 4. Contained in the following commands: CREATE TGTFDD, GET TGTFDD, SET TGTFDD, CREATE TGTTDD, GET TGTTDD, SET TGTTDD Maximum number of MSU available for retransmission. Validity range: n1 100..127 <DEFAULT> (default value: 110) Contained in the following commands: CREATE OPC, GET OPC, SET OPC Maximum number of MSU octets available for retransmission. Validity range: n2 2000..4000 <DEFAULT> 1632 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller N2WC N3101 N3101TD N3103 (default value: 3000) Contained in the following commands: CREATE OPC, GET OPC, SET OPC This parameter is included in the X25A and X25D configuration message (IXLT restart). Validity range: numberOf2WayChannels 0..4095 <DEFAULT> (default value: 6) Contained in the following commands: CREATE X25A, GET X25A, SET X25A, CREATE X25D, GET X25D, SET X25D This parameter implements the threshold for non valid data error coming by mobile station after having sent USF. In case this threshold is reached, the communication with the associated MS is broken. Validity range: n3101 9..255 <DEFAULT> (default value: 10) Contained in the following commands: CREATE PCU, GET PCU, SET PCU This parameter implements the threshold for non valid data error coming by mobile station after having sent USF. In case this threshold is reached, the communication with the associated MS is broken. Validity range: n3101TD 9..255 <DEFAULT> (default value: 25) Contained in the following commands: CREATE PCUTD, GET PCUTD, SET PCUTD This parameter implements the threshold for not received Packet Control Ack as answer of the Packet Uplink Ack/Nack. In case this threshold is reached, the communication with the associated MS is broken. Validity range: n3103 1..255 <DEFAULT> (default value: 10) Contained in the following commands: CREATE PCU, GET PCU, SET PCU A30808-X3247-L230-3-7619 1633 Commands Base Station Controller CML:BSC N3103TD N3105 N3105TD N391 This parameter implements the threshold for not received Packet Control Ack as answer of the Packet Uplink Ack/Nack. In case this threshold is reached, the communication with the associated MS is broken. Validity range: n3103TD 1..255 <DEFAULT> (default value: 5) Contained in the following commands: CREATE PCUTD, GET PCUTD, SET PCUTD This parameter implements the threshold for not received RLC/MAC control message fromthe MSafter sending a RRBPfield on downlink. If threshold is reached, the communication with the associated MS is broken. Validity range: n3105 1..255 <DEFAULT> (default value: 10) Contained in the following commands: CREATE PCU, GET PCU, SET PCU This parameter implements the threshold for not received RLC/MAC control message fromthe MSafter sending a RRBPfield on downlink. If threshold is reached, the communication with the associated MS is broken. Validity range: n3105TD 1..255 <DEFAULT> (default value: 5) Contained in the following commands: CREATE PCUTD, GET PCUTD, SET PCUTD This parameter represents the polling cycle. It means that after N expirations of T391 a Status Enquiry requiring a full status shall be sent to SGSN. Validity range: n391 1..255 <DEFAULT> (default value: 6) Contained in the following commands: CREATE FRL, GET FRL, SET FRL 1634 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller N392 N393 NALLWACC NAVGI This attribute represents the error threshold on polling procedure (based on N391 counter) used to put the FRL in Disabled state. Validity range: n392 1..255 <DEFAULT> (default value: 3) Contained in the following commands: CREATE FRL, GET FRL, SET FRL This attribute represents the error observation window. If threshold N392 is reached on N393 * T391 timer, the links are put in disabled state. If the threshold is not reached the counters are restarted. Validity range: n393 1..255 <DEFAULT> (default value: 4) Contained in the following commands: CREATE FRL, GET FRL, SET FRL This attribute contains a list of MS Access Classes, which are not allowed to get access to the cell. It should be noted that the access class number na10 does not exist as a normal access class because it is used for emergency calls. Validity range: notAllowedAccessClasses 1 to 15 items max list (NALLWACC1&NALLWACC2..) For each NALLWACC<n> the notAllowedClass field can be set to: na0, na1, na2, na3, na4, na5, na6, na7, na8, na9, na11, na12, na13, na14, na15, ALLALLOWED (na10 is used for Emergency call class) (default value: ALLALLOWED) If ALLALLOWED is set then all the other fields are skipped (Both in SET and in GET Command) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD This attribute represents an interfering signal strength filter constant for power control 2(k/2), k = 0, 1, , 15. Validity range: nAverageInterference 0..15 <DEFAULT> A30808-X3247-L230-3-7619 1635 Commands Base Station Controller CML:BSC NAVGITD NBLKACGR NBVCBR NBVCRR (default value: 10) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute represents an interfering signal strength filter constant for power control 2(k/2), k = 0, 1, , 15. Validity range: nAverageInterferenceTD 0..15 <DEFAULT> (default value: 10) Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD This attribute specifies the number of CCCH blocks reserved for the Access Grant channel within a period of 51 TDMA frames (a multi- frame). A block consists of 4 consecutive TDMA frames. Validity range: noOfBlocksForAccessGrant 0..7 <DEFAULT> (default value: 0) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter, used in BVCI block procedure, indicates the number of repetitions of block procedure in case of not answering fromSGSN, before sending an O&M alarm. Validity range: numberOfBvcBlockRetries 1..30 <DEFAULT> (default value: 3) Contained in the following commands: CREATE PCU, GET PCU, SET PCU, CREATE PCUTD, GET PCUTD, SET PCUTD This parameter, used in BVCI reset procedure, indicates the number of repetitions of reset procedure in case of not answering fromSGSN, before sending an O&M alarm. Validity range: numberOfBvcResetRetries 1..30 <DEFAULT> (default value: 3) Contained in the following commands: CREATE PCU, GET PCU, SET PCU, CREATE PCUTD, GET PCUTD, SET PCUTD 1636 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller NBVCUR NCC1TH NCC1THADJC This parameter, used in BVCI unblock procedure, indicates the number of repetitions of unblock procedure in case of not answering from SGSN, before sending an O&M alarm. Validity range: numberOfBvcUnblockRetries 1..30 <DEFAULT> (default value: 3) Contained in the following commands: CREATE PCU, GET PCU, SET PCU, CREATE PCUTD, GET PCUTD, SET PCUTD This attribute establishes the threshold concerning the C1 value: when a mobile has its C1 value under this threshold , it is moved to an adjacent suitable cell. The following list shows the correspondence between selected values and real values: DB00 0 dB DB01 1 dB .... .... .... DB63 63 dB Validity range: NcC1Threshold DB00...DB63 <DEFAULT> (default value: DB03 [3 dB]) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute establishes the threshold concerning the C1 value for an adjacent cell. The following list shows the correspondence between selected values and real values: DB00 0 dB DB01 1 dB .... .... .... DB63 63 dB Validity range: NcC1ThresholdAdjacent DB00...DB63 <DEFAULT> (default value: DB05 [5 dB]) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC A30808-X3247-L230-3-7619 1637 Commands Base Station Controller CML:BSC NCDP1 NCDP2 NCELL NCGPENTIME The attribute allows to configure the first time-frame for the sleeping cell detection procedure. StartTime1 represents the beginning of the time-frame.TimerNoCall1 represents the observation period. Validity range: startTime1 H0 ... H23 (default value: H5) timerNoCall1 1..432 (periods of 10 min) (default value: 1) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD The attribute allows to configure the second time-frame for the sleeping cell detection procedure. StartTime2 represents the begin- ning of the time-frame. TimerNoCall2 represents the observation period. Validity range: startTime2 H1..H23, NOTUSED (default value: NOTUSED) timerNoCall2 1..138 (periods of 10 min) (default value:<NULL>) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD This attribute defines the number of preferred cells for the evaluation of the target cell list in the HO_COND_IND message. Validity range: nCell 0..15 (default value: 6) Contained in the following commands: GET HAND, SET HAND, GET HANDTD, SET HANDTD This attribute gives the duration for which the NcGprsTemporary- Offset is applied in GPRS Network Controlled Cell Reselection proce- dure. The following list shows the correspondence between selected values and real values: SEC000 0 seconds SEC001 1 second SEC002 2 seconds 1638 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller NCGRESOFF NCGTEMPOFF SEC320 320 seconds Validity range: NcGprsPenaltyTime SEC000...SEC320 <DEFAULT> (default value: SEC000 [0 s]) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC This attribute specifies to mobile station the positive or negative offset and hysteresis to be applied to C32 value in the GPRS Netwrok Controlled Cell Reselection procedure . The set value ranges from -52 dB to +48 dB. MDB52 -52 dB MDB51 -51 dB ..... ...... MDB10 -10 dB MDB9 -9 dB ..... ...... DB22 +22 dB DB23 +23 dB ..... ...... DB48 +48 dB Validity range: ncGprsReselecOffset MDB52....DB48 <DEFAULT> (default value: DB00 [0 dB]) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC This attribute applies a negative offset to C32 for the duration of NcGprsPenaltyTime in GPRS Network Controlled Cell Reselection Procedure .. The set value ranges from 0 dB to 60 dB. The value NEVER means infinity. DB00 0 dB DB01 1 dB ..... ...... ..... ...... DB59 +59 dB DB60 +60 dB Validity range: ncGprsTemporaryOffset MDB52....DB48 NEVER <DEFAULT> (default value: DB00 [0 dB]) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC A30808-X3247-L230-3-7619 1639 Commands Base Station Controller CML:BSC NCRARESH NCRESELFLAG NCSARA This attribute specifies the offset to apply to C32 of adjacent cell not belonging to the same routing area of serving cell .It has to be set to 0 (its default value ), when the NcSameRoutingArea (NCSARA parameter) is set to TRUE The following list shows the correspondence between selected values and real values: DB00 0 dB DB01 1 dB .... .... .... DB30 30 dB Validity range: ncRaReselectHysteresis DB00...DB63 <DEFAULT> (default value: DB00 [0 dB]) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter enable/disable the network cell reselection feature Validity range: ncReselectionFlag DISABLE, ENABLE <DEFAULT> (default value: DISABLE) Contained in the following commands: SET BSC, GET BSC When this attribute is set to TRUE , the adjacent cell is searched before among the cells belonging to same routing area of serving cell. When this attribute is set to FALSE , the adjacent cells of the same routing area have not priority compared to the adjacent cells of other routing areas When this attribute is set to TRUE , the attribute sbsN- cRaReselectHysteresis has to be set to 0 (DB00) , which is its default value Validity range: ncSameRoutingArea TRUE FALSE <DEFAULT> (default value: TRUE) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF 1640 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller NCTRFPSCTH NE NECI NELIST This attribute indicates the threshold under which no other gprs mobiles are ordered to change cell. Validity range: ncTrafcPSControlTh- reshold 30,,100 (step 1) <DEFAULT> (default value: 75) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute defines the type and the instance number of the Network Element, connected to the BSC, that must be aligned. Validity range: networkEntity Ne: BTSE TRAUE BTSEC Addr1: 0..363 Contained in the following commands: ALIGN REMINV The parameter defines if new establishment causes are supported by the network. Validity range: newEstablishCauseIndication TRUE FALSE <DEFAULT> (default value: FALSE) Contained in the following commands: GET BSC, SET BSC This attribute defines the set of identifiers where downloading the software load. The max number of elements in NELIST is 100 for BTSE and 20 for TRAU. Validity range: neList NE_NUMBER_000..NE_NUMBER_199 Contained in the following commands: NEDOWNLOAD NEYESUSW A30808-X3247-L230-3-7619 1641 Commands Base Station Controller CML:BSC NETWTYPE NEWESU NF1 NFLPD This parameter indicates the type of network. Validity range: networkType GSMDCS GSMPCS GSMR GSM850PCS GSM850DCS GSMRAILPUB GSMDCSTSM GSMPCSTSM <DEFAULT> (default value: GSMDCS) Contained in the following commands: GET BSC, SET BSC This read-only parameter defines indicates which software will be used in the next change version operation. Validity range: newESU pathname Contained in the following commands: GET BSCOSUDB, GET BSCOSUSW This parameter, during handover, indicates the maximum number of downlink FRAME NUMBER INFO messages on the air interface. The user equipment must establish the LAPDm link for signalling within this time. Otherwise the handover failed and this is signalled on the Abis inter- face in an connectio failure indication message with cause Handover Access Failure Validity range: nf1 1..254 (default value:127) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter defines the number of frame advance used for linear prediction. Validity range: numOfFrLinPreDelay 0..15 <DEFAULT> (default value: 3) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD 1642 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller NFRAMEPG NIOC NMDLATT<nn> NMO This value specifies the number of multiframes (51 frames) between two transmissions of the same paging message to mobiles of the same paging group. Validity range: noOfMultiFramesBetweenPaging 2..9 <DEFAULT> (default value: 2) Contained in the following commands: CREATE BTS,GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD This read-only parameter defines the number of incoming only channels, included in the X25A and X25D configuration message (IXLT restart). Validity range: numberOfIncomingOnly 0..4095 (default value: 3) Contained in the following commands: GET X25A, GET X25D Therty two parameters are provided (<nn> from 1 to 32). This parameter defines a pair of BCCH frequencies-BSIC for Normal Measures observation. Each parameter consists of three fields: bcchFrequency, netColorCode and bsColorCode. Validity range: normalMeasAttr<nn> bcchFrequency 0..1023 netColorCode 0..7 bsColorCode 0..7 The <NULL> value can be set for each NMDLATT<nn> parameter. Contained in the following commands: CREATE SCA, GET SCA, SET SCA Network mode of operation (I, II and III). Validity range: networkModeOfOperation NMO_1 NMO_2 NMO_3 <DEFAULT> (default value: NMO_2) Contained in the following commands: CREATE PCU, GET PCU, SET PCU, CREATE PCUTD, GET PCUTD, SET PCUTD A30808-X3247-L230-3-7619 1643 Commands Base Station Controller CML:BSC NMULBAC NNSVCBLKR NNSVCRR NNSVCTSTR This attribute specifies the minimum number of neighbour cells reported by MS not belonging the frequency band of the serving cell (see Recc. GSM 5.08 v4.18.1 par. 8.4 for more detailed description). Validity range: nMultibandcell 0..3 <DEFAULT> (default value: 0) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD This parameter specifies the maximum number of retries performed in the NSVC block procedure. If the SGSN does not answer to block procedure, the procedure shall be retried for NNSVCBLKR times. Validity range: numberOfNsvcBlockRetries 1..254 <DEFAULT> (default value: 3) Contained in the following commands: CREATE PCU, GET PCU, SET PCU, CREATE PCUTD, GET PCUTD, SET PCUTD This parameter specifies the maximum number of retries performed in the NSVC reset procedure before generating any alarm. If the SGSN does not answer to reset procedure, the procedure shall be retried infinitely but after NNSVCRR times an O&M alarm shall be notified. Validity range: numberOfNsvcResetRetries 1..254 <DEFAULT> (default value: 10) Contained in the following commands: CREATE PCU, GET PCU, SET PCU, CREATE PCUTD, GET PCUTD, SET PCUTD This parameter defines the number of consecutive retries performed for test procedure before declaring link not available. Validity range: numberOfNsvcTestRetries 1..30 <DEFAULT> (default value: 10) Contained in the following commands: CREATE PCU, GET PCU, SET PCU, CREATE PCUTD, GET PCUTD, SET PCUTD 1644 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller NNSVCUBLR NOBAKHO NOCHBLKN NOCHFBLK NOFREPHO This parameter specifies the maximum number of retries performed in the NSVC block procedure. If the SGSN does not answer to unblock procedure, the procedure shall be retried for NNSVCUBLR times. Validity range: numberOfNsvcUnblockRetries 1..254 <DEFAULT> (default value: 3) Contained in the following commands: CREATE PCU, GET PCU, SET PCU, CREATE PCUTD, GET PCUTD, SET PCUTD This attribute is used to enable/disable the Prevention of Back Handover feature. Validity range: enableNobackHo TRUE FALSE (default value: TRUE) Contained in the following commands: GET HAND, SET HAND, GET HANDTD, SET HANDTD This parameter indicates the number of CCCH blocks to be used for the NCH channel (a block consists of 4 consecutive TDMA frames). Validity range: notificationChannelBlockNumber 1..4 <DEFAULT> (default value: 1) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter indicates the first CCCHblock to be used for the NCH channel (a block consists of 4 consecutive TDMA frames). Validity range: notificationChannelFirstBlock 1..7 <DEFAULT> (default value: 1) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This attribute is used to enable/disable the Prevention of Handover failures repetition feature. Validity range: enableNoFailRepHo FALSE TRUE A30808-X3247-L230-3-7619 1645 Commands Base Station Controller CML:BSC NOOC NORTSUBS NOTFACCH (default value: TRUE) Contained in the following commands: GET HAND, SET HAND, GET HANDTD, SET HANDTD This read-only parameter defines the number of outgoing only chan- nels, included in the X25A and X25D configuration message (IXLT restart). Validity range: numberOfOutgoingOnly 0..4095 (default value: 0) Contained in the following commands: GET X25A, GET X25D This timer is started and incremented if no receive signal is detected. If the timer elapses the sector antenna is used. Validity range: noRXTimerSubsec 1..10 (measurement reporting period unit) <DEFAULT> (default value: 10) Contained in the following commands: CREATE SWIBEAM, GET SWIBEAM, SET SWIBEAM This parameter indicates the Notification/FACCH message that will be sent for some kind of calls. Validity range: notificationOnFACCH ALWAYS (Notification/FACCH will always be sent) HIGHEQ4 (Notification/FACCH will always be sent for calls having priority equal or higher than 4) HIGHEQ3 (Notification/FACCH will always be sent for calls having priority equal or higher than 3) HIGHEQ2 (Notification/FACCH will always be sent for calls having priority equal or higher than 2) HIGHEQ1 (Notification/FACCH will always be sent for calls having priority equal or higher than 1) HIGHEQ0 (Notification/FACCH will always be sent for calls having priority equal or higher than 0) HIGHEQB (Notification/FACCH will always be sent for calls having priority equal or higher than B) 1646 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller NREPEV NREPIEV NRLCMAX NRLCMAXTD EQA (Notification/FACCH will always be sent for calls having priority equal to A) NOSUPP (Notification/FACCH not supported) (default value: NOSUPP) Contained in the following commands: GET BSC, SET BSC This parameter defines the maximal number of reported eigenvalues of signal matrix. Validity range: numRepEV 1..8 <DEFAULT> (default value: 3) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter defines the maximal number of eported eigenvalues of interference matrix. Validity range: numRepIntEV 1..8 <DEFAULT> (default value: 1) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD When N_RLC_MAX Uplink RLC Blocks are received, one PACKET UPLINK ACK/NACK is sent in acknowledged mode. Validity range: numberRlcMax 20..64 <DEFAULT> (default value: 20) Contained in the following commands: CREATE PCU, GET PCU, SET PCU When N_RLC_MAX Uplink RLC Blocks are received, one PACKET UPLINK ACK/NACK is sent in acknowledged mode. Validity range: numberRlcMaxTD 20..64 (default value: 20) Contained in the following commands: CREATE PCUTD, GET PCUTD, SET PCUTD A30808-X3247-L230-3-7619 1647 Commands Base Station Controller CML:BSC NRPGRANT NSEI NSLOTST NSVCI NSVLI The numberRepetitionGrant used maximumnumber of the repetition of the VGCS_UPLINK_GRANT message during an uplink access procedure.. Validity range: numberRepetitionGrant 1..254 <DEFAULT> (default value: 20) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter represents the PCU area identification. This attribute can be set only if the object PCU is in locked state. Validity range: networkServiceElementIdentifier 0..65534 Contained in the following commands: CREATE PCU, GET PCU, SET PCU, CREATE PCUTD, GET PCUTD, SET PCUTD This attribute is used to represent the maximum number of RACH slots an MS must wait, after an unsuccessful randomaccess attempt, before a new random access. The MS draws a random number between 0 and the value of this parameter allows the access retransmission to be spread over a fixed number of RACH slots. Validity range: numberOfSlotSpreadTrans 0..15 <DEFAULT> (default value: 10) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter represents the common identification of the virtual connection between SGSN and BSS. Validity range: nsvcIdentifier 0..65535 Contained in the following commands: CREATE NSVC, GET NSVC The NSVCI (Network Service Virtual Link Identifier) parameter defines the association of the FR-DLCI (Data Link Connection Identifier) and the FRL (Frame Relay Link). It consists of two mandatory fields: FRLN and DLCIN. Validity range: nsvlIdentifier FRLN 0..377 1648 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller NTWCARD NTWCOR NTWCORTD DLCIN 16..991 Contained in the following commands: CREATE NSVC, GET NSVC This attribute indicates the network card in use. Validity range: networkCard NTWSN16, NTWSNAP, NTWSNAP_STLP (default value: NTWSN16) Contained in the following commands: GET BSC, SET BSC This parameter, reported in SI 13, PSI 1 and PSI 5, informs the mobile about the control of cell reselection. Validity range: networkControlOrder NC0: MS controlled cell reselection, no meas reporting; NC1: MS controlled cell reselection, MS sends meas report; <DEFAULT> (default value: NC0) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter, reported in SI 13, informs the mobile about the control of cell reselection. In BR7.0 only NC0 and NC1 will be consid- ered. Validity range: networkCon- trolOrderTD NC0: UE controlled cell reselection, no meas reporting; NC1: UE controlled cell reselection, MS sends meas report; NC2: NTWcontrolled cell reselection, UE sends meas report; <DEFAULT> (default value: NC1) Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD A30808-X3247-L230-3-7619 1649 Commands Base Station Controller CML:BSC NTWCNDRXP NTWCREPPIDL NTWCREPPTR NTWEL This parameter indicates the minimum time the mobile station shall stay in non-DRX mode after an NCmeasurement report has been sent. Validity range: networkControlNonDRXPe- riod NODRX, MSEC240, MSEC480, MSEC720, MSEC960, MSEC1200, MSEC1440, MSEC1920 <DEFAULT> (default value: MSEC480) Contained in the following commands: CREATE PTPPKF, SET PTPPKF, GET PTPPKF This field indicates the time period for cell reselection measurement reporting when ms is in packet idle mode Validity range: networkControlReportPeri- odIdle MSEC480 , MSEC960 ,MSEC1920 ,MSEC3840,MSEC7680,MSEC15360, MSEC30720, MSEC61440 <DEFAULT> (default value: MSEC61440) Contained in the following commands: CREATE PTPPKF, SET PTPPKF, GET PTPPKF This field indicates the time period for cell reselection measurement reporting when ms is in packet transfer mode Validity range: networkControlReportPeri- odTransfer MSEC480 , MSEC960 ,MSEC1920 ,MSEC3840,MSEC7680,MSEC15360, MSEC30720, MSEC61440 <DEFAULT> (default value: MSEC3840) Contained in the following commands: CREATE PTPPKF, SET PTPPKF, GET PTPPKF This attribute specifies the Network Element. Validity range: networkElement BTSE TRAUE BTSEC Contained in the following commands: GET NEYESUSW, NEDOWNLOAD NEYESUSW, GET RSUSWLH 1650 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller NTWIND NUA NY1 OBJLST (Network Indicator) Signalling Network Indicator where the BSS is connected. Validity range: networkIndicator INAT0,INAT1,NAT0,NAT1 for CCITT NAT0 for ANSI <DEFAULT> (default value:NAT0) Contained in the following commands: CREATE OPC, GET OPC Not Urgent Alarm: it is used to enable or disable the handling of Not Urgent Alarm on the 2 Mbit/s port. This attribute is significative only for PCM30 lines Validity range: nua FALSE: disabled, TRUE: enabled <NULL> (default value: FALSE) Contained in the following commands: CREATE PCMA, GET PCMA, CREATE PCMB, GET PCMB, SET PCMB, CREATE PCMG, GET PCMG, SET PCMG, CREATE PCMS, GET PCMS, SET PCMS This attribute indicates the maximum number of repetitions of the PHYSICAL INFORMATION message on the radio interface. This message is sent by the BTS to the MS during a handover procedure between two not synchronized cells, in order to establish a physical channel connection on the new cell. Validity range: ny1 1..254 <DEFAULT> (default value: 50) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter provides choices for the definition of monitored object; it is mandatory for the CREATE commands. Validity range: objectList selfAdapting 0..0 selectObjects the max number of items and the fields displayed depend on the scanner type. A30808-X3247-L230-3-7619 1651 Commands Base Station Controller CML:BSC SCANAIRTSTD Items: 1..10 BtsmTdld: 0..363 BtsTdld: 0..2 TrxTdld: 0..2 AirtsTdList: All List: 0..6 SCANBTS and SCANGPRS Items: 1..50 btsmld: 0..199 btsld: 0..23 SCANBTSABISTD Items: 1..50 btsmTdld: 0..363 btsTdld: 0..2 SCANBTSM List 1..100 of 0..199 SCANBTSMTD List 1..100 of 0..363 SCANFBTSM Items: 1..100 Btsmld: 0..199 SCANSS7L List 1..16 of 0..15 SCANTRX Items: 1..25 btsmld: 0..199 btsld: 0..23 trxld: 0..23 SCANTRXTD and SCANTRXABISTD Items: 1..25 BtsmTdld: 0..363 BtsTdld: 0..2 TrxTdld: 0..2 For the SCANBTSE object: objectList selfAdapting 0..0 btsList 1..50 items and for each: btsmld: 0..199 btsld: 0..23 For the SCANCTRX object: objectList selfAdapting 0..0 trxList 1..25 items and for each: btsmId: 0..199 btsId: 0..23 trxId: 0..23 For the SCANBTSOHOI and SCANBTSOHON objects: objectList 1..10 items and for each item we can define: btsld btsmId 0..199 btsId 0..23 adjcId selfAdapting 0..0 selectObjects List 1..32 of 0..31 For the SCANBTSOHOS object: objectList 1..10 items and for each item we can define: btsld btsmId 0..199 1652 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller btsId 0..23 adjc3gList selfAdapting 0..0 selectObjects List 1..32 of 0..31 For the SCANBTSTD and SCANGPRSTD object: objectList 1..50 items and for each item we can define: btsmTdId 0..363 btsTdId 0..2 For the SCANBTSTDIHDO object: objectList 1..10 items and for each item we can define: Btstdld Btsmtdld 0..363 Btstdld 0..2 BtsTdAdjcList selfAdapting 0..0 origBtsGroup: 1..16 items and for each: Btsmtdld 0..363 Btstdld 0..2 For the SCANBTSOHDOI and SCANBTSOHDON objects: objectList 1..10 items and for each item we can define: btstdld btsmtdId 0..363 btstdId 0..2 BtstdAdjcList selfAdapting 0..0 selectObjects List 1..32 of 0..31 For the SCANCHAN object: objectList 1..10 items and for each item we can define: btsmId 0..199 btsId 0..23 trxId 0..23 chanId allTch 0..0 list: chan0..chan7 Contained in the following commands: CREATE SCANAIRTSTD, GET SCANAIRTSTD, SET SCANAIRTSTD, CREATE SCANBTS, GET SCANBTS, SET SCANBTS, CREATE SCANBTSABISTD, GET SCANBTSABISTD, SET SCANBTSABISTD, CREATE SCANBTSE, GET SCANBTSE, SET SCANBTSE, CREATE SCANBTSM, GET SCANBTSM, SET SCANBTSM, CREATE SCANBTSMTD, GETSCANBTSMTD, SET SCAN- BTSMTD, CREATE SCANBTSOHOI, GET SCANBTSOHOI, SET SCANBTSOHOI, CREATE SCANBTSOHON, GET SCANBTSOHON, SET SCANBTSOHON, CREATE SCANBTSOHOS, SET SCANBTSOHOS, CREATE SCAN- BTSTD, GET SCANBTSTD, SET SCANBTSTD, CREATE SCANBT- STDIHDO, GET SCANBTSTDIHDO, SET SCANBTSTDIHDO, CREATE SCANBTSTDOHDOI, GET SCANBTSTDOHDOI, CREATE SCANBTSTDOHDOI,CREATE SCANBTSTDOHDON, GET SCANBTSTDOHON, SET SCANBTSTDOHDON, A30808-X3247-L230-3-7619 1653 Commands Base Station Controller CML:BSC OMCCPT OMLAPDRT OPC CREATE SCANCHAN, GET SCANCHAN, SET SCANCHAN, CREATE SCANCTRX, GET SCANCTRX, SET SCANCTRX, CREATE SCANFBTSM, GET SCANFBTSM, SET SCANFBTSM, CREATE SCANGPRS, GET SCANGPRS, SET SCANGPRS, CREATE SCANGPRSTD, GET SCANGPRSTD, SET SCANG- PRSTD, CREATE SCANSS7L, GET SCANSS7L, SET SCANSS7L, CREATE SCANTRX, GET SCANTRX, SET SCANTRX CREATE SCANTRXABISTD, GET SCANTRXABISTD, SET SCANT- RXABISTD, CREATE SCANTRXTD, GET SCANTRXTD, SET SCANTRXTD This parameter represents the time period of the reachability test performed by RC on the "cold standby" OMAL. Validity range: omcCapabilityTimer 1..60 (1 minute step size) <DEFAULT> <NULL> (default value: 60) Contained in the following commands: CREATE OMAL, GET OMAL, SET OMAL At the detection time of the Abis link failure the BTSE starts the timer OMLAPDRT and the BSC starts the timer SHLAPDIT. If the timer OMLAPDRT expires, the BTSE blocks the cell processing. After that the BTSE forces the BSC (via a RestartSendingEventReports - NACK message) to performa complete Abis alignment. If none of the two timers expire, the BSC performs a "Short Abis alignment". Validity range: omLapdRelTimer 3..300 (1 s step size) <DEFAULT> (default value: 30) Contained in the following commands: CREATE BTSM, GET BTSM, SET BTSM, CREATE BTSMTD, GET BTSMTD, SET BTSMTD This attribute identifies the originating system (BSS). It consists of three fields: NetworkClusterMember, NetworkCluster, NetworkIdentifier. Validity range: networkClusterMember 0-255 for CCITT 1-255 for ANSI networkCluster 0-63 for CCITT 0-255 for ANSI networkIdentifier NO_CONFIG for CCITT 1654 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller OUTPUT OVERWRITE OVLENTHR OVLSTTHR 1-254 for ANSI Contained in the following commands: CREATE OPC, GET OPC This attribute identifies the file name where to store ECHO outputs. Validity range: output 80 characters string Contained in the following commands: SET This parameter specifies if the file has to be overwritten or not. Validity range: overWrite YES NO Contained in the following commands: DNLFILE, UPLALLCELLTR CTRCO, UPLCELLTR CTRCO, UPLCIDF REMINV, UPLLIDF REMINV, UPLFILE, UPLBTSLOG, UPLBTSTDLOG, UPLMEAS SCANCO, UPLTRAULOG, UPLALLIM- SITR TRACE, UPLIMSITR TRACE, UPLOADREQ SCA, UPLOA- DREQ RFLOOP, UPLPRLOG FILEHANDLER End threshold for Overload Handling within BSC. The value refer to TDPC processor load, expressed as 100 * <TDPC processor real- time> (e.g. 8000 means TDPC real-time = 80%). Validity range: ovlEndThreshold 7000..10000 (default value: 8500) Contained in the following commands: GET BSC, SET BSC Start threshold for Overload Handling within BSC. The value refer to TDPC processor load, expressed as 100 * <TDPC processor real-time> (e.g. 8000 means TDPC real-time = 80%). Validity range: ovlStartThreshold 7000..10000 (default value: 9500) Contained in the following commands: GET BSC, SET BSC A30808-X3247-L230-3-7619 1655 Commands Base Station Controller CML:BSC OWR This parameter defines if the file present in the destination directory (DESTDIR parameter) ha to be overwritten or not. Validity range: overWrite YES NO Contained in the following commands: UPLDFILE RSUDB 1656 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller A30808-X3247-L230-3-7619 1657 Commands Base Station Controller CML:BSC PATHNAME - X121ADDR PATHNAME PATHLSLOPE This parameter defines the pathname of the file which must be deleted. Validity range: pathName 1..59 characters string Contained in the following commands: DELETE FILEHANDLER GENFILE This parameter defines The path loss slope is approximated by a function: where: y = a log (bx) where: a is given in dB: 20, 22.5, 57.5. b is 0.1/(4000 pi) and it is varying by +0, 2.5, 37.5 dB. x represents the UE-network distance and it is measured in km. Validity range: pathLossSlope <DEFAULT> aPar N_0 N_1 N_2 bPar N_0 N_1 N_2 Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD. 1658 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PAVRLEV PAVRQUAL The PAVRLEV (Power Control Averaging Level) defines the averaging parameters for the signal level measurements. All the level-measurements concerning power-control pass an averaging algorithm. The algorithm can be described as a window. All values inside the window are used to calculate the arithmetic average. The window is a queue: when a new measurement is received, the oldest measurement is removed from the window. The parameter used in the process are the averaging period (in SACCH periods) and the DTX weighting factor. The averaging period is the size of the window, the DTX weighting factor determines how much more measurements with DTX not active (i.e. speech transmitted) are weighted than those with DTX active (i.e. no speech transmitted). For the latter case (DTX active) the weighting factor is always 1. The values entered for this parameter are valid for both the uplink and downlink measurement. This parameter consists of two mandatory fields: A_Lev_PC (Averaging Level Power Control) and w_Lev_PC (Weighting Level Power Control). Validity range: pcAverangingLev A_Lev_PC 1..31 (unit of 1 SACCH multiframe, step size 1) (default value: 2) w_Lev_PC 1..3 (step size 1) (default value: 2) Contained in the following commands: GET PWRC, SET PWRC The PAVRQUAL (Power Control Averaging Parameters Quality) defines the averaging parameters for the signal quality measurements. All the quality-measurements concerning power-control pass an averaging algorithm. For the averaging principle, parameter format and parameter meaning please refer to the explanation given for the previous parameter PAVRLEV. The values entered for this parameter are valid for both the uplink and downlink measurement reports. This parameter consists of two mandatory fields: A_Qual_PC (Averaging Quality Power Control) and w_Qual_PC (Weighting Quality Power Control). Validity range: pcAverangingQual A_Qual_PC 1..31 (unit of 1 SACCH multiframe, step size 1) (default value: 2) w_Qual_PC 1..3 (step size 1) A30808-X3247-L230-3-7619 1659 Commands Base Station Controller CML:BSC PBGTHO PCCCHLDI PCCPCHDESC PCLOWTARQDUL (default value: 2) Contained in the following commands: GET PWRC, SET PWRC This attribute indicates whether handover due to power budget is enabled or disabled. Validity range: enablePowerBudgetHo FALSE TRUE (default value: TRUE) Contained in the following commands: GET HAND, SET HAND, GET HANDTD, SET HANDTD This value indicates the frequency which the CCCH load indication is sent to the BSC. The CCCH load indication is sent to BSC only when the threshold TCCCHLDI is reached. Validity range: periodCcchLoadIndication 0..255 (1 s step size) <DEFAULT> (default value: 255) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD This parameter defines It defines the number of blocks per multiframe on P-CCPCH reserved for BCCH, AGCH, CBCH, other use ( e.g. NCH ). Validity range: pCCPCHDesc Blk_BCCH 1..2 Blk_AGCH 0..7 Blk_CBCH 0..1 Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD. This parameter defines the lower BER threshold on uplink. Relevant for circuit switched data services. If the reported BER is below this threshold, the UL signal power is decreased. Validity range: pcLowTarQualFacDataUL -4.030..0.000 (step 0.065) <DEFAULT> 1660 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PCLOWTARQPTKUL PCLOWTARQSHUL PCLOWTHBPTKUL PCLOWTHBSHUL (default value: -0.13) Contained in the following commands: GET PWRCTD, SET PWRCTD This parameter defines the lower BER threshold on uplink. Relevant for packet switched dataservices. If the reported BER is below this threshold, the UL signal power is decreased. Validity range: pcLowTarQualFacPack- etUL -4.030..0.000 (step 0.065) <DEFAULT> (default value: -0.13) Contained in the following commands: GET PWRCTD, SET PWRCTD This parameter defines the lower BER threshold on uplink; relevant for speech services. If the reported BER is below this threshold, the UL signal power will be decreased. Validity range: PcLowTarQualFacSpee- chUL -4.030..0.000 (step 0.065) <DEFAULT> (default value: -0.13) Contained in the following commands: GET PWRCTD, SET PWRCTD This parameter defines the lower BLER threshold on uplink; relevant for packet switched data services. If the reported BLER is below this threshold, the pcUpTarQualPacketUL (PCUPTARQUPTKUL parameter) is increased by pcQualStepSizeUp (PCQUSSUP parameter) dB. Validity range: PcLowThrBlerPacketUL -4.030..0.000 (step 0.065) <DEFAULT> (default value: -0.975) Contained in the following commands: GET PWRCTD, SET PWRCTD This parameter defines the lower BLER threshold on uplink; relevant for speech services. If the reported BLER is below this threshold, the pcUpTarQualSpeechUL (PCUPTARQUSHUL parameter) is increased by pcQualStepSizeUp (PCQUSSUP parameter) dB. Validity range: pcLowThrBlerSpeechUL -4.030..0.000 (step 0.065) A30808-X3247-L230-3-7619 1661 Commands Base Station Controller CML:BSC PCMBSTXPRL PCMCON0 PCMCON1 <DEFAULT> (default value: -0.975) Contained in the following commands: GET PWRCTD, SET PWRCTD This attribute defines the absolute maximum base station transmis- sion power reduction level (in 2dB steps). Validity range: pcMaxBsTxPowerRedLev 0..15 <NULL> (default value: 15) Contained in the following commands: GET PWRC, SET PWRC This attribute indicates the main PCMconnection for the given BTSM. Validity range: pcmConnection0 <DEFAULT> <NULL> PcmbNumber PCMB_0, ..., PCMB_117; PortNumber PORT_0, (see Application Guide- lines n. 5. and n. 6. of the CREATE BTSM command) PORT_2, PORT_4, PORT_6 (default value: <NULL>) Contained in the following commands: CREATE BTSM, GET BTSM, SET BTSM, CREATE BTSMTD, GET BTSMTD, SET BTSMTD This attribute indicates the first auxiliar PCMconnection for the given BTSM. Validity range: pcmConnection1 <DEFAULT> <NULL> PcmbNumber PCMB_0, ..., PCMB_117; PortNumber PORT_0, (see Application Guide- lines n. 5. and n. 6. of the CREATE BTSM command) PORT_2, PORT_4, PORT_6 1662 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PCMCON2 PCMCON3 PCMECH (default value: <NULL>) Contained in the following commands: CREATE BTSM, GET BTSM, SET BTSM, CREATE BTSMTD, GET BTSMTD, SET BTSMTD This attribute indicates the second auxiliar PCM connection for the given BTSM (it is not allowed for BS-82). Validity range: pcmConnection2 <DEFAULT> <NULL> PcmbNumber PCMB_000, ..., PCMB_117; PortNumber PORT_0, PORT_2, PORT_4, PORT_6 (default value: <NULL>) Contained in the following commands: CREATE BTSM, GET BTSM, SET BTSM, CREATE BTSMTD, GET BTSMTD, SET BTSMTD This attribute indicates the third auxiliar PCMconnection for the given BTSM (it is not allowed for BS-82). Validity range: pcmConnection3 <DEFAULT> <NULL> PcmbNumber PCMB_000, ..., PCMB_117; PortNumber PORT_0, PORT_2, PORT_4, PORT_6 (default value: <NULL>) Contained in the following commands: CREATE BTSM, GET BTSM, SET BTSM, CREATE BTSMTD, GET BTSMTD, SET BTSMTD This attribute indicates where the mobile station shall measure the received power level on the downlink for the purpose of the uplink power control. Validity range: powerControlMeasurementChannel A30808-X3247-L230-3-7619 1663 Commands Base Station Controller CML:BSC PCML PCMSN PCMSOBJ PCMT MEABCCH means downlink measurements for power control shall be made on BCCH; MEAPDTCH means downlink measurements for power control shall be made on PDCH. <DEFAULT> (default value: MEABCCH) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF PCMline identity: it defines the LICD number, the circuit number and the trunk which the pcm line is connected to. Validity range: pcmLine Licdn 0..9 Circn 0..3 (QTLP) 0..5 (STLP) Trunk TRUNKA (only for PCMG object) TRUNKB (only for PCMG object). Contained in the following commands: CREATE PCMB, GET PCMB, CREATE PCMG, GET PCMG, CREATE PCMS, GET PCMS This parameter identifies the PCMline on A-sub interface connected to TRAU. Validity range: pcmsNumber 0..35 Contained in the following commands: CREATE TRAU, GET TRAU This parameter specifies the PCMS line which the synchronization signal is derived from. Validity range: relatedPcmsObject 0..35 Contained in the following commands: CREATE SYNC, GET SYNC This parameter defines the TRAU number and the circuit number where the PCMA line (PCM line of A interface) is connected to. It consists of two mandatory fields: Traun and Circn. Validity range: pcmt Traun 0..35 1664 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PCMTYPE PCONINT PCQUSSDOWN Circn 0..3 Contained in the following commands: CREATE PCMA, GET PCMA This attribute specifies the maximumnumber of timeslots available of each PCM line. Validity range: pcmType PCM30 (line with time slots from 0 to 31) PCM24 (line with a time slot from 1 to 24) (default value: PCM30) Contained in the following commands: GET BSC, SET BSC This attribute contains the minimum time period between two successive modifications of the RF power level of one MS, i.e. before expiring of that timer started after setting up a power command, new power control decision processes are suspended. Validity range: powerControlInterval 0-31 unit of 2 SACCH multiframes (default value: 2) Contained in the following commands: GET PWRC, SET PWRC This parameter defines the Down Stepsize for Uplink Power Control used for: Decrease SIRTarget in case of reported bit error rate is below a given threshold: pcLowTarQualData, pcLowTarQualPacket or pcLowTarQualSpeech. Decrease 'BER Upper Threshold' in case of reported block error rate (BLER) is below a given threshold pcLowThrBler- Packet or pcLowThrBlerSpeech. Validity range: pcQualStepSizeDown 0.1..3.0 dB (step 0.1) <DEFAULT> (default value: 0.3 dB) Contained in the following commands: GET PWRCTD, SET PWRCTD A30808-X3247-L230-3-7619 1665 Commands Base Station Controller CML:BSC PCQUSSUP PCRLFTH PCUID PCUPTARQUDUL This parameter defines the Up Stepsize for Uplink Power Control used for: Increase SIR Target in case of reported bit error rate is above a given threshold pcUpTarQualData, pcUpTarQualPacket or pcUpTarQualSpeech. Increase BER Upper Threshold in case of reported block error rate (BLER) is above a given threshold pcUpThrBler- Packet or pcUpThrBlerSpeech. Validity range: pcQualStepSizeUp 0.1..3.0 dB (step 0.1) <DEFAULT> (default value: 1.0 dB) Contained in the following commands: GET PWRCTD, SET PWRCTD This attribute defines the threshold value for the radio link counter for RLF warning detection. Validity range: pcRLFThreshold 0..64 (1 SACCH multiframe step size) (default value: 18) Contained in the following commands: GET PWRC, SET PWRC This attribute defines which PCU or PCUTD the FRL is connected to. Validity range: pcuIdentifier Pathname Contained in the following commands: CREATE FRL, GET FRL This parameter defines the upper BER threshold on uplink; relevant for circuit switched data services. If the reported BER is above this threshold, the UL signal power is increased. Validity range: pcUpTarQualDataUL -4.030..0.000 (step 0.065) <DEFAULT> (default value: -0.975) Contained in the following commands: GET PWRCTD, SET PWRCTD 1666 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PCUPTARQUPTKUL PCUPTARQUSHUL PCUPTHBPTKUL PCUPTHBSHUL This parameter defines the upper BER threshold on uplink; relevant for packet switched dataservices. If the reported BER is above this threshold, the UL signal power is increased. Validity range: pcUpTarQualPacketUL -4.030..0.000 (step 0.065) <DEFAULT> (default value: -0.975) Contained in the following commands: GET PWRCTD, SET PWRCTD This parameter defines the upper BER threshold on uplink; relevant for speech services. If the reported BER is above this threshold, the UL signal power is increased. Validity range: pcUpTarQualSpeechUL -4.030..0.000 (step 0.065) <DEFAULT> (default value: -0.975) Contained in the following commands: GET PWRCTD, SET PWRCTD This parameter defines the upper BLER threshold on uplink; relevant for packet data services. If the reported BLERis above this threshold, the pcUpTarQualPacketUL (PCUPTARQUPTKUL)is decreased by pcQualStepSizeDown (PCQUSSDOWN parameter) dB Validity range: pcUpThrBlerPacketUL -4.030..0.000 (step 0.065) <DEFAULT> (default value: -0.975) Contained in the following commands: GET PWRCTD, SET PWRCTD This parameter defines the lower BLER threshold on uplink; relevant for speech services. If the reported BLER is below this threshold, the pcUpTarQualSpeechUL (PCUPTARQUSHUL parameter) is ncreased by pcQualStepSizeUp (PCQUSSUP parameter) dB. Validity range: PcUpThrBlerSpeechUL -4.030..0.000 (step 0.065) <DEFAULT> (default value: -0.975) Contained in the following commands: GET PWRCTD, SET PWRCTD A30808-X3247-L230-3-7619 1667 Commands Base Station Controller CML:BSC PENTIME PERM PERSTLVPRI1 PERSTLVPRI2 This attribute gives the duration for which the temporary offset is applied. Validity range: penaltyTime 0..30 (20 s step size) : (20..260 s) 31: this value indicates that CellReselectOffset is subtracted from C2 and temporaryOffset is ignored <NULL> (default value: 0) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD. This parameter can be equal to TRUE or FALSE. If it is set equal to TRUE the patch is automatically loaded at the next bring-up operation; otherwise it is not loaded. Validity range: permanent TRUE FALSE Contained in the following commands: CREATE RSUPCH, GET RSUPCH, SET RSUPCH This parameter is put in System Information in order to inform MS about Channel Request/Packet Channel Request/EGPRS Packet Channel Request retransmission in case of TBF with priority 1. Validity range: persistenceLevelPriority1 0..15 <DEFAULT> (default value: 5) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter is put in system Information in order to inform MS about Channel Request/Packet Channel Request/EGPRS Packet Channel Request retransmission in case of TBF with priority 2. Validity range: persistenceLevelPriority2 0..15 <DEFAULT> (default value: 5) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF 1668 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PERSTLVPRI3 PERSTLVPRI4 PERWEEK PFACHDESC This parameter is put in system Information in order to inform MS about Channel Request/Packet Channel Request/EGPRS Packet Channel Request retransmission in case of TBF with priority 3. Validity range: persistenceLevelPriority3 0..15 <DEFAULT> (default value: 5) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter is put in system Information in order to inform MS about Channel Request/Packet Channel Request/EGPRS Packet Channel Request retransmission in case of TBF with priority 4. Validity range: persistenceLevelPriority4 0..15 <DEFAULT> (default value: 5) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute identifies a list of periods, one for every day of the week. Every period has start time and stop time. Validity range: periodWeekly all 0..0 weekly: <day_of_week> noSched 0..0 suPeriod: startHour 0..23 startMinute 0..59 stopHour 0..23 stopMinute 0..59 where <day_of_week> is equal to: sunday, monday, tuesday, wednesday, thursday, friday, saturday. Contained in the following commands: CREATE CTRSCHED, GET CTRSCHED, SET CTRSCHED This parameter describes each configured P-FACH in term of assigned RUs, associated P-RACH. Validity range: pFACHDesc timeSlot 4..6 TSC 0..15 Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD A30808-X3247-L230-3-7619 1669 Commands Base Station Controller CML:BSC PH PHYADDR PKAVDRELTH PKAVDTH This read-only parameter is used to identify the current loading phase. Validity range: phase IDLE LOAD_BACKUP_ESU_SW LOAD_NEW_ESU_SW ACCEPT_NEW_ESU_SW WAIT_FOR_ACCEPT_NEW_ESU_SW LOAD_BACKUP_ESU_DB LOAD_NEW_ESU_DB SAVE_DB_IN_PROGRESS DOWNLOAD_NE ACTIVATE_NE ALIGN_NE ABORT_ALIGN_NE Contained in the following commands: GET BTSMOSUSW, GET BTSMTDOSUSW, GET BSCOSUSW, GET TRAUOSUSW This attribute identifies the physical address where to read data. Validity range: physicalAddress 0..FFFFFFF (hexadecimal value) Contained in the following commands: MEMDUMP BSC This parameter defines a threshold that is used for detection of SYNC1 signature. Validity range: peakAverDiffRelThres 11..21 dB (1 dB step size) <DEFAULT> (default value: 15 dB) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD. This parameter defines a threshold for that is used for detection of SYNC1 signature. Validity range: peakAverageDiffThres 8..18 dB (1 dB step size) <DEFAULT> (default value: 12 dB) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD 1670 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PKNWK PKRXPLUPDESTD PKSDDCOLLTH PKSDDTH This attribute defines the initial value of Pk counter at network side on an uplink primary channel. The network initialises the counter Pk to pkNWK value decreasing them by 1 if it is unable to decode a radio block and increasing them by 2 in the case of a successful reception of one radio block. This counter shall never exceed the pkNWK value. If Pk counter reaches 0 the network releases the packet connection. A change of the attribute becomes effective at the next packet access. Validity range: pkNWK 1..255 RLC/MAC blocks, where RLC (Radio Link Control) MAC (Medium Access Control) (default value: 20) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter represents the expected receive power level on the UpLink PDPCH and it is coded as the RSCP measured at the BSS. The network insert this value on IMMEDIATE ASSIGNMENT message. Validity range: packetRXPowerLevU- plinkDesTD -120.5 .. 80 dBm (0.5 dBm step size) <DEFAULT> Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD This parameter defines a threshold that is used for detection SYNC1 signature. Validity range: peakSideDiffCollThres 1..9 dB (1 dB step size) <DEFAULT> (default value: 6 dB) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter defines a threshold that is used for detection of SYNC1 signature. Validity range: peakSideDiffThres 2..6 dB (1 dB step size) <DEFAULT> (default value: 4 dB) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD A30808-X3247-L230-3-7619 1671 Commands Base Station Controller CML:BSC PKTMEASREPCNT PKSIDEDTH PKTNDEC PKTNDECTD This attribute indicates the number of consecutive serving cells BCCH carrier measurements under threshold NCC1TRSH , which are necessary to order a cell change. Validity range: packetMeasurementRe- portCounter 1..10 (step 1) <DEFAULT> (default value: 1) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter defines, for detection SYNC1 collision, a threshold for the time difference between peak point and side points. Validity range: peakSideTimeDiffThres 0..16 <DEFAULT> (default value: 6 dB) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter defines the number of decrements for counter N3102, performed if the T3182 expires without reception of packet uplink ACK/NACK. It is used for RLC layer at MS side. If PKTNDEC is set at zero the N3102 counter shall be disabled by the mobile station. Validity range: packetNumberDecrement 0..7 <DEFAULT> (default value: 2) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter defines the number of decrements for counter N3102, performed if the T3182 expires without reception of packet uplink ACK/NACK. It is used for RLC layer at MS side. If PKTNDECTD is set at zero the N3102 counter shall be disabled by the mobile station. Validity range: packetNumberDecre- mentTD 0..7 <DEFAULT> (default value: 2) Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD 1672 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PKTNINC PKTNINCTD PKTNMA PKTNMATD This parameter defines the number of increments for counter N3102 performed after receiving the packet uplink ACK/NACK. It is used for RLC layer at MS side. If PKTNINC is set at zero the N3102 counter shall be disabled by the mobile station. Validity range: packetNumberIncrement 0..7 <DEFAULT> (default value: 2) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter defines the number of increments for counter N3102 performed after receiving the packet uplink ACK/NACK. It is used for RLC layer at MS side. If PKTNINCTD is set at zero the N3102 counter shall be disabled by the mobile station. Validity range: packetNumberIncre- mentTD 0..7 <DEFAULT> (default value: 2) Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD This parameter defines the maximum value for counter N3102. If N3102 exceeds PAKTNMA or N3102 reaches 0 or less than 0, a RLC abnormal release shall be performed. If PANDECor PANINCor PKTNMAare set at zero the N3102 counter shall be disabled by the mobile station. Validity range: packetNumberMax 0..7 <DEFAULT> (default value: 4) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter defines the maximum value for counter N3102. If N3102 exceeds PAKTNMATD or N3102 reaches 0 or less than 0, a RLC abnormal release shall be performed. If PKTNDECTD or PKTNINCTD or PAKTNMATD are set at zero the N3102 counter shall be disabled by the mobile station. Validity range: packetNumberMaxTD 0..7 <DEFAULT> (default value: 4) Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD A30808-X3247-L230-3-7619 1673 Commands Base Station Controller CML:BSC PKUE PL PLMNP This parameter represents a counter that controls the P-PDCH main- tenance procedure at the UE side. Validity range: pkUE WAIT_002BP WAIT_032BP WAIT_004BP WAIT_064BP WAIT_008BP WAIT_128BP WAIT_016BP WAIT_256BP <DEFAULT> Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD The attribute defines the priority layer of the serving cell. Validity range: priorityLayer 0..15 (0 highest priority, 15 lowest priority) (default value: 0) Contained in the following commands: GET HAND, SET HAND The PLMNP(PLMNPermitted) parameter corresponds to the IENCC Permitted. The decimal value entered is sent to the MS as an 8-bit string on the BCCH(SYS_INFO_Type 2) in order to indicate allowed NCCs for cell selection (idle) or on the SACCH (SYS_INFO_Type6) in order to indicate allowed NCCs for measurement reports (busy). The 8-bit string is used as a bit-map; every 1 bit indicates that the NCC corresponding to the bit position is allowed. i j The value of the PLMNP is equal to the sum of i*2exp(j) where: i = 0 or i = 1 is the value of a single bit 0 <= j <= 7 is the value of the position of the bit. Validity range: plmnPermitted 0..255 <DEFAULT> (default value: 255) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD. 1674 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PLNC POOLTYP PPLNC The attribute defines the priority layer of the neighbour cell (0 highest priority; 15 lowest priority). Validity range: priorityLayerNCell 0..15 <DEFAULT> (default value: 0) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC, CREATE ADJC3G, GET ADJC3G, SET ADJC3G The attribute defines the type of the pool assigned to the given TSLA. For pool type meaning see Appendix B: Tab. 6.14. Validity range: PoolType POOL_NOTDEF POOL_1 POOL_2 POOL_3 POOL_4 POOL_5 POOL_6 POOL_7 POOL_8 POOL_9 POOL_10 POOL_11 POOL_12 POOL_13 POOL_15 POOL_16 POOL_17 POOL_18 POOL_19 POOL_20 POOL_21 POOL_22 POOL_23 POOL_24 POOL_25 POOL_26 POOL_27 POOL_28 POOL_29 POOL_30 POOL_31 POOL_32 POOL_33 POOL_34 POOL_35 POOL_42 POOL_43 POOL_44 POOL_45 POOL_46 POOL_47 POOL_48 (default value: POOL_NOTDEF) Contained in the following commands: GET TSLA, SET TSLA This parameter is relevant for speed sensitive handover; it determines the temporary priority layer of the neighbour cell. Validity range: penalityPriorityLayerNCell 0..15 <DEFAULT> A30808-X3247-L230-3-7619 1675 Commands Base Station Controller CML:BSC PRACHDESC PREFPRIO PREFSF PRIDLFG (default value: 0) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC, CREATE ADJC3G, GET ADJC3G, SET ADJC3G This parameter describes each configured P-RACH in term of assigned RUs, associated AGCH. Validity range: pRACHDesc timeSlot 1..3 TSC 0..15 SC 0..23 p_RACH_AGCH 0..1 Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter is used by BSC to decide if either current or default priorities are to be considered in priority based admission control when DCA is disabled. Validity range: prefPriorities DEFAULT CURRENT <DEFAULT> (default value: DEFAULT) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter specifies which SF (Spreading Factor) has to be preferred in case an even number of resource units is required and the selected Timeslot is fully idle. Validity range: preferredSF SF_ALL_8 SF_ALL_16 SF_DYNAMIC <DEFAULT> (default value: SF_DYNAMIC) Contained in the following commands: CREATE AIRTSTD, GET AIRTSTD, SET AIRTSTD This parameter defines the forgetting factor, which is used in the recursive averaging algorithm for updating the priority values of the DL timeslots. The priority values are based on interference measurements. They are needed for Priority based Admission Control. Validity range: 1676 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PRIMARYIPADDR PRIORITY PRIOSLOTN PRIUDPDL priorityDLForget 0..100 (1/100 step size) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This attribute is the Ip address that is assigned to the Providing service MPCC port. The RC and CBC always use this address when calling the BSC. The convention used for his value is the well-known dotted decimal format (e.g. 172.31.21.88). Validity range: PrimaryIpAddress string 7..15 chars Contained in the following commands: CREATE IPLI, GET IPLI,SET IPLI This attribute assigns a priority to the script execution (0 = fastest, 10 = slowest). Validity range: priority 0..10 Contained in the following commands: SET, EXEC This attribute stores an integer value; at bring up, the loading sequence of the patches will be determined by sorting the patches in function of the slot number. Validity range: prioritySlotNumber 0..65000 <NULL> (default value: <NULL> for the unpatches; a value which will cause the patch to be loaded after the ones currently created (i.e. the current maximumslot number plus one) for the patches. Contained in the following commands: CREATE RSUPCH, SET RSUPCH This parameter defines the sending rate of the message RF_TS_PRIORITY_UPDATE_IND to the BSC. The message contains the priority values for DL timeslots, which are needed for Priority based Admission Control. Validity range: priorityUpdatePeriodDL 1..255 s Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD A30808-X3247-L230-3-7619 1677 Commands Base Station Controller CML:BSC PRIUDPUL PRIULFG PROCTYP PRPBCCH This parameter defines the sending rate of the message RF_TS_PRIORITY_UPDATE_IND to the BSC. The message contains the priority values for UL timeslots, which are needed for Priority based Admission Control. Validity range: priorityUpdatePeriodUL 1..255 s Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter defines the forgetting factor, which is used in the recursive averaging algorithm for updating the priority values of the UL (Uplink) timeslots. The priority values are based on interference measurements and they are needed for priority based admission control. Validity range: priorityULForget 0..100 (1/100 s step size) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD. This field identifies the processor type for the file to be transferred in the BSC disk. Validity range: processorType BSCI SWLH IXLT PPCU PPCC PPLD TDPC MSCI DSP ACTAM ALCO BBSIG CCTRL CCLK LI TRXA TRAC TRXD VAMBSC VAMBTSE VAMTRAU PPXL (*) PPXU (*) MPCC GENERICEXE (*) Prepared in advance. Contained in the following commands: GET RSUEXE, CREATE RSUPCH, GET RSUPCH This attribute indicates the power reduction value used by the BTS on PBCCH blocks, relative to the output power used on BCCH. Validity range: powerReductionOnPbcch 0..15 (-2 dB step size) 1678 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PSTEPDL PSTEPUL PTSUBS PUREBBSIG44CONF <DEFAULT> (default value: 0) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter defines the step size for downlink power control. Validity range: powerStepDL N_1_dB N_2_dB N_3_dB <DEFAULT> (default value: N_1_dB) Contained in the following commands: GET PWRCTD, SET PWRCTD This parameter defines the step size of adjustment when doing uplink power control. Validity range: powerStepUL N_1_dB N_2_dB N_3_dB <DEFAULT> (default value: N_1_dB) Contained in the following commands: GET PWRCTD, SET PWRCTD This timer is started and incremented after a switch to the sector antenna. A switch back is not performed before the timer elapses, in order to avoid too many switches. Validity range: penaltyTimerSubsec 0..10 (measurement reporting period unit) <DEFAULT> (default value: 4) Contained in the following commands: CREATE SWIBEAM, GET SWIBEAM, SET SWIBEAM This attribute states if a BTS1 is equipped with all BBSIG44 (TRUE) or equipped with at least one old BBSIG (FALSE). It is up to the operator to ensure the consistency between the attribute value and the BS-2x/6x equipment. In case of BS-4x/240/241/240XL, BS-82 and BS-242 the attribute is not meaningful, and its value must be <NULL>. Validity range: pureBbsig44Config TRUE FALSE <NULL> A30808-X3247-L230-3-7619 1679 Commands Base Station Controller CML:BSC PVC PWRCONF PWREDSS PWRINCSS PWROFS (default value: FALSE) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This read-only parameter defines the number of PVCs, included in the X25A and X25D configuration message (IXLT restart). Validity range: pvc 0..4095 (default value: 0) Contained in the following commands: GET X25A, GET X25D This attribute defines the maximum interval for confirmation of the new RF power level in units of two SACCH multiframes. Validity range: powerConfirm 1-31 (unit of 2 SACCH multiframes) (default value: 2) Contained in the following commands: GET PWRC, SET PWRC This attribute defines the step size used when reducing the MS transmit power. Validity range: powerRedStepSize db2,db4 (default value: db2) Contained in the following commands: GET PWRC, SET PWRC This attribute defines the step size used when increasing the MS transmit power. Validity range: powerIncrStepSize db2,db4,db6 (default value: db6) Contained in the following commands: GET PWRC, SET PWRC This parameter defines the additional power to MS on RACH access.The attribute is meaningless for all the cells not DCS1800. Validity range: powerOffset 0..3 (unit of dB, step size 2 dB) <DEFAULT> 1680 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller PWROUT PWRPFACH PWRRED (default value: 0) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This attribute defines the three power output thresholds: - oPwrFaultThreshold: defines the minimal output power level "transmitter-fault" which results in generating an alarm to the CCTRL. - redOutPwrThreshold: defines the power level when a warning is generated. - excesOutPwrThresh: defines the power level when a major alarm is generated due to too much power level at the PA output. Validity range: oPwrFaultThreshold m10db, m8db (default value: m10db) redOutPwrThreshold m10db, m8db, m6db, m4db (default value: m6db) excesOutPwrThresh db3, db5 (default value: db5) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter defines the transmit power on PFACH. Validity range: pwrPFACH -12..0 dBm (step 1) <DEFAULT> (default value: ) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This attribute specifies the number of 2 dB steps the TX power should be reduced from the maximum transmit power, for tuning the cell coverage. The resulting attenuated transmit power is the maximum nominal power Pn. Validity range: txPwrMaxReduction 0..6 (2 dB step size) <DEFAULT> (default value: 6) Contained in the following commands: CREATE TRX, GET TRX, SET TRX A30808-X3247-L230-3-7619 1681 Commands Base Station Controller CML:BSC QL QSRHCINI QSRHC QSRHI This attribute specifies the maximum number of TCH requests that can be queued in the cell. Validity range: queuingLength 1..100 <DEFAULT> (default value: 50) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This attribute indicates the value to be used before the Qsearch_c value is received in measurement information message. Validity range: qSearchCinitial QSEARCHI ALWAYS <DEFAULT> (default value: QSEARCHI) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This attribute defines a threshold which enables the searching for 3G cells in case of handover measurements on other radio access technologies. Validity range: qSearchC UMDB98 UMDB94 UMDB90 UMDB86 UMDB82 UMDB78 UMDB74 ALWAYS OMDB78 OMDB74 OMDB70 OMDB66 OMDB62 OMDB58 OMDB54 NEVER <DEFAULT> (default value: NEVER) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This attribute defines a threshold which enables the searching for 3G cells with regard to cell reselection; it has to be handled because it is the default value of the attribute QSRHCINI (qSearchCinitial). Validity range: qSearchI UMDB98 UMDB94 UMDB90 UMDB86 UMDB82 UMDB78 UMDB74 ALWAYS 1682 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller QSRHPRI R20 R22 OMDB78 OMDB74 OMDB70 OMDB66 OMDB62 OMDB58 OMDB54 NEVER <DEFAULT> (default value: NEVER) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter defines a threshold and it indicates if the measurements have to be made by mobile when the signal is under or above the threshold; the value is expressed in dB. Validity range: qSearchPriority UMDB98 UMDB94 UMDB90 UMDB86 UMDB82 UMDB78 UMDB74 ALWAYS OMDB78 OMDB74 OMDB70 OMDB66 OMDB62 OMDB58 OMDB54 NEVER <DEFAULT> (default value: NEVER) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF Restart request retry count. Validity range: restartRequestRetryCount 1..255 <DEFAULT> (default value: 3) Contained in the following commands: CREATE X25A, GET X25A, SET X25A, CREATE X25D, GET X25D, SET X25D Reset request retry count. Validity range: resetRequestRetryCount 1..255 <DEFAULT> (default value: 3) Contained in the following commands: CREATE X25A, GET X25A, SET X25A, CREATE X25D, GET X25D, SET X25D A30808-X3247-L230-3-7619 1683 Commands Base Station Controller CML:BSC R23 RAARET RACHBT RACHLAS Clear request retry count. Validity range: clearRequestRetryCount 1..255 <DEFAULT> (default value: 3) Contained in the following commands: CREATE X25A, GET X25A, SET X25A, CREATE X25D, GET X25D, SET X25D This parameter indicates whether randomaccess retry to another cell is allowed (TRUE value) or not (FALSE value). Validity range: randomAccessRetry FALSE, TRUE, <DEFAULT> (default value: TRUE) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute defines a threshold for the received signal level during network access and handover access. A signal level exceeding this threshold is interpreted as a busy RACH or a busy FACCH (when transmitting CHANNEL REQUEST (RACH) or Handover ACCESS (FACCH)). Validity range: rachBusyThreshold 0..127 (-1 dBm step size) <DEFAULT> (default value: 109) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD. This attribute defines the number of RACH bursts over which RACH measurements are performed. Validity range: rachLoadAverangingSlots 102..65535 <DEFAULT> (default value: 204) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD. 1684 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller RACODE RACOL RADIOMG RADIOMR This attribute represents the identification of the RA which this cell belongs to. Validity range: routingAreaCode 0..255 Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF, CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD CREATE TGTPTPPKF, GET TGTPTPPKF, SET TGTPTPPKF This attribute is used by the mobile to identify the specific routing area. Validity range: routingAreaColour 0..7 (default value: 0) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF, CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD, CREATE TGTPTPPKF, GET TGTPTPPKF, SET TGTPTPPKF This attribute specifies the granularity in which the radio measurements have to be transmitted on the A-bis interface in case they are enabled. Validity range: radioMeasGran 1..254 (1 SACCH multiframe step size) <DEFAULT> (default value: 254) Contained in the following commands: CREATETRX, GET TRX, SET TRX, CREATETRXTD, GET TRXTD, SET TRXTD This parameter specifies whether the radio measurements have to be transmitted on the A-bis interface. Validity range: radioMeasRep ON, OFF, <DEFAULT> (default value: OFF) Contained in the following commands: CREATETRX, GET TRX, SET TRX, CREATETRXTD, GET TRXTD, SET TRXTD A30808-X3247-L230-3-7619 1685 Commands Base Station Controller CML:BSC RAENV RARESH RAVEW RDGRDL This parameter specifies the radio environment in the cell. It is an indicator of user mobility. Two values are possible: LOWDIV (lowDiversity): it means that for a MS radio conditions can change slowly, because the cell is characterized by low user mobility (pico cells, indoor cells, or MSs have a speed lower than 50 km/h). HIGHDIV (highDiversity): it means that for a MS radio conditions can change fast, because MSs have a speed higher than 50 km/h. Validity range: radioEnvironment LOWDIV, HIGHDIV, <DEFAULT> (default value: HIGHDIV) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter indicates the additional hysteresis to be subtracted from C32, when the mobile is selecting a cell in a new Routing Area (RA). Validity range: routingAreaReselectHysteresis 0..7 (2 dB step size) (default value: 2 [4 dB]) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF The attribute specifies the averaging windowsize, in SACCHperiods, (how many measurement samples) used in the gliding averaging process for rate up-downgrading for 14.4 kbit/s data services. Validity range: rateAveragingWindow 4..32 <NULL> (default value: 8) Contained in the following commands: GET HAND, SET HAND Downgrade threshold (14.4 kbit/s -> 9.6 kbit/s) for downlink direction. Validity range: rateDowngradeDownlink 1..6 <NULL> (default value: 2) For the values make references to Appendix B: Group 3. Contained in the following commands: GET HAND, SET HAND 1686 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller RDGRUL RDLNKTBS RDLNKTBSTD Downgrade threshold (14.4 kbit/s -> 9.6 kbit/s) for uplink direction. Validity range: rateDowngradeUplink 1..6 <NULL> (default value: 2) For the values make references to Appendix B: Group 3. Contained in the following commands: GET HAND, SET HAND The radioLinkTimeout attribute is used to indicate the maximumvalue of the radio link counter needed to detect a radio link failure in the BS. The radio link failure criterion is based on the radio link counter called 'S'. If the BS is unable to decode a SACCH message, S is decreased by 1, while in the case of a successful reception of a SACCH message, S is increased by 2. In any case, S shall not exceed the value of RDLNKTBS. If S reaches 0, a radio link failure shall be signalled to BSC. Validity range: radioLinkTimeoutBs 4..64 (step size 4) (default value: 20) Contained in the following commands: GET PWRC, SET PWRC The radioLinkTimeout attribute is used to indicate the maximumvalue of the radio link counter needed to detect a radio link failure in the BS. The radio link failure criterion is based on the radio link counter called 'S'. If the BS is unable to decode a SACCH message, S is decreased by 1, while in the case of a successful reception of a SACCH message, S is increased by 2. In any case, S shall not exceed the value of RDLNKTBSTD. If S reaches 0, a radio link failure shall be signalled to BSC. Validity range: radioLinkTimeoutBsTD 4..64 (step size 4) <DEFAULT> (default value: 20) Contained in the following commands: GET PWRCTD, SET PWRCTD A30808-X3247-L230-3-7619 1687 Commands Base Station Controller CML:BSC RDLNKTO RECCRI RECINT The radioLinkTimeout attribute is used to indicate the maximumvalue of the radio link counter needed to detect a radio link failure. This value is used by the MS procedure and may also be used for the BSS procedure. This attribute corresponds to the radio sub-system link control parameter RADIO_LINK_TIMEOUT. The radio link failure criterion is based on the radio link counter called 'S'. If the MS is unable to decode a SACCH message, S is decreased by 1, while in the case of a successful reception of a SACCH message, S is increased by 2. In any case, S shall not exceed the value of RADIO_LINK_TIMEOUT. If S reaches 0, a radio link failure shall be declared. The radio-link-timeout parameter ranges from 4 to 64 SACCH blocks at steps of 4 SACCH blocks. Note that S=4+RDLNKTO*4. Validity range: radioLinkTimeout 0..15 <DEFAULT> (default value: 4) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD This attribute specifies the criteria in which the trace are collected in the BSC. Validity range: recordCriteria NO_CRITERIA, <DEFAULT> Contained in the following commands: CREATE TRACE, GET TRACE This parameter specifies the type of periods (recording intervals) in which scanner must be activated. Validity range: recordingInterval all 0..0 daily: items 1..7 and for each item: startHour 0..23 startMinute 0..59 stopHour 0..23 stopMinute 0..59 weekly: sunday: noSched 0..0 period: startHour 0..23 startMinute 0..59 stopHour 0..23 stopMinute 0..59 monday: noSched 0..0 period: startHour 0..23 startMinute 0..59 1688 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller stopHour 0..23 stopMinute 0..59 tuesday: noSched 0..0 period: startHour 0..23 startMinute 0..59 stopHour 0..23 stopMinute 0..59 wednesday: noSched 0..0 period: startHour 0..23 startMinute 0..59 stopHour 0..23 stopMinute 0..59 thursday: noSched 0..0 period: startHour 0..23 startMinute 0..59 stopHour 0..23 stopMinute 0..59 friday: noSched 0..0 period: startHour 0..23 startMinute 0..59 stopHour 0..23 stopMinute 0..59 saturday: noSched 0..0 period: startHour 0..23 startMinute 0..59 stopHour 0..23 stopMinute 0..59 (default value: all) Contained in the following commands: CREATE SCANAIRTSTD, GET SCANAIRTSTD, SET SCANAIRTSTD, CREATE SCANBSC, GET SCANBSC, SET SCANBSC, CREATE SCANBTS, GET SCANBTS, SET SCANBTS, CREATE SCANBTSABISTD, GET SCANBTSABISTD, SET SCAN- BTSABISTD, CREATE SCANBTSE, GET SCANBTSE, SET SCAN- BTSE, CREATE SCANBTSIHO, GET SCANBTSIHO, SET SCANBTSIHO, CREATE SCANBTSM, GET SCANBTSM, SET SCANBTSM, CREATE SCANBTSMTD, GETSCANBTSMTD, SET SCANBTSMTD, CREATE SCANBTSOHOI, GET SCANBT- SOHOI, SET SCANBTSOHOI, CREATE SCANBTSOHON, A30808-X3247-L230-3-7619 1689 Commands Base Station Controller CML:BSC RELATIVEPCR RELF GET SCANBTSOHON, SET SCANBTSOHON, CREATE SCANBTSOHOS, SET SCANBTSOHOS, CREATE SCAN- BTSTD, GET SCANBTSTD, SET SCANBTSTD, CREATE SCANBT- STDIHDO, GET SCANBTSTDIHDO, SET SCANBTSTDIHDO, CREATE SCANBTSTDOHDOI, GET SCANBTSTDOHDOI, CREATE SCANBTSTDOHDOI,CREATE SCANBTSTDOHDON, GET SCANBTSTDOHON, SET SCANBTSTDOHDON, CREATE SCANCHAN, GET SCANCHAN, SET SCANCHAN, CREATE SCANCTRX, GET SCANCTRX, SET SCANCTRX, CREATE SCANFBTSM, GET SCANFBTSM, SET SCANFBTSM, CREATE SCANGPRS, GET SCANGPRS, SET SCANGPRS, CREATE SCANGPRSTD, GET SCANGPRSTD, SET SCANG- PRSTD, CREATE SCANSS7L, GET SCANSS7L, SET SCANSS7L, CREATE SCANTRX, GET SCANTRX, SET SCANTRX, CREATE SCANTRXABISTD, GET SCANTRXABISTD, SET SCANTRX- ABISTD, CREATE SCANTRXTD, GET SCANTRXTD, SET SCANT- RXTD This parameter defines the maximal transmit power difference between any two users within a time slot during ownlink power control. The step size is 1 dB and its range is from0 dB to 31 dB and its initial value is set to 12dB currently. Validity range: relativePCRangeDL 0..31 <DEFAULT> (default value:12) Contained in the following commands: GET PWRCTD, SET PWRCTD This attribute univocally identifies a physical file on the BSCdisk. The file can be: - a software load header file (related to a RSUSWLH object instance) - an executable file (related to a RSUEXE object instance) - a database file (related to a RSUDB object instance) - a patch file (related to a RSUPCH object instance). After the download procedure (i.e. after the CREATE command of a RSUobject instance), the relatedFiles field of the created RSUobject instance contains the completed path of the physical file stored on BSC disk. Validity range: relatedFiles 1..59 characters string Contained in the following commands: GET RSUDB, GET RSUSWLH, GET RSUEXE,GET RSUPCH 1690 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller RELRSU REMAL REPMETHD This read-only parameter defines the instance of Reusable Software Unit DB that is related to the BSC Executable Software Unit DB. Validity range: relatedRSU pathname Contained in the following commands: GET BSCESUDB, GET BSCESUSW, GET NEYESUSW Remote alarm type. This attribute is significative only for PCM24 lines. Validity range: remoteAlarmType CCITT BELLCORE <NULL> (default value: CCITT) Contained in the following commands: CREATE PCMA, GET PCMA, CREATE PCMB, GET PCMB, SET PCMB, CREATE PCMG, GET PCMG, SET PCMG, CREATE PCMS, GET PCMS, SET PCMS This attribute specifies whether reports have to be shown through spontaneous messages or through files. The selected value BYMSG means that the reports are sent to OMC/LTPC by spontaneous messages. The selected value BYFILE means that the reports are stored on BSC disk. Validity range: scannerReportMethod BYMSG, BYFILE, <DEFAULT> (default value: BYFILE) Contained in the following commands: GET SCANAIRTSTD, CREATE SCANBSC, GET SCANBSC, SET SCANBSC, GET SCANBTS, GET SCANBTSABISTD, GET SCAN- BTSE, GET SCANBTSIHO, GET SCANBTSM, GETSCANBTSMTD, GET SCANBTSOHOI, GET SCANBTSOHON, GET SCANBTSOHOS, GET SCANBTSTD, GET SCANBTST- DIHDO, GET SCANBTSTDOHDOI, GET SCANBTSTDOHON, GET SCANCHAN, GET SCANCTRX, GET SCANFBTSM, GET SCANGPRS, GET SCANGPRSTD, CREATE SCANSS7L, GET SCANSS7L, SET SCANSS7L, GET SCANTRX, GET SCANTRXABISTD, GET SCANTRXTD A30808-X3247-L230-3-7619 1691 Commands Base Station Controller CML:BSC REPTYP REQATTL RETRY RFRSINDP RHOLTQDL This attribute indicates to the mobile to use the ENHANCED MEASUREMENT REPORT or MEASUREMENT REPORT messages for measurements reporting. Validity range: reportType NORMAL ENHANCED (default value: NORMAL) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter defines the list of the attributes whose status or value can be displayed by the operator. Validity range: listOfRequiredAttributes list of the parameters related to the selected object Contained in the following commands: GET commands Retry Number. Validity range: retryNumber 1..254 <DEFAULT> (default value: 8) Contained in the following commands: CREATE X25A, GET X25A, SET X25A, CREATE X25D, GET X25D, SET X25D This attribute defines the sending rate of the radio signalling message RFRESIND to the BSC. Validity range: rfResourceIndicationPeriod 1..254 (1 SACCH multiframe step size) <DEFAULT> (default value: 60) Contained in the following commands: CREATE BTS, GET BTS, SET BTS The attribute defines the receive signal quality threshold on downlink for handover decision for data calls where the rate up/downgrading mechanism is applied. Validity range: rateHoLowerThresholdQualDownlink 2..7 <NULL> (default value: 3) 1692 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller RHOLTQUL RNCID RSCPMIC RSSILVR For the values make references to Appendix B: Group 3. Contained in the following commands: GET HAND, SET HAND The attribute defines the receive signal quality threshold on uplink for handover decision for data calls where the rate up/downgrading mechanism is applied. Validity range: rateHoLowerThresholdQualUplink 2..7 <NULL> (default value: 3) For the values make references to Appendix B: Group 3. Contained in the following commands: GET HAND, SET HAND This attribute represents the RNC. Validity range: rncId 0..4095 <DEFAULT> (default value: 0) Contained in the following commands: CREATE TGTFDD, GET TGTFDD,SET TGTFDD, CREATE TGTTDD, GET TGTTDD, SET TGTTDD This attribute defines the minimumRSCPof the DwPTSof a neighbor cell that is neccessary for a handover to that cell. Validity range: rSCPMinCell -120..-25 (step 1) <NULL> Contained in the following commands: CREATE ADJCTD, GET ADJCTD, SET ADJCTD This attribute specifies the ranges for counters for RSSI Measure. Validity range: utranTxCodePowerRange List 7..7 of 0..63 (default value: 7-15-23-31-39-47-55) Contained in the following commands: CREATE SCANAIRTSTD, GET SCANAIRTSTD, SET SCANAIRTSTD. A30808-X3247-L230-3-7619 1693 Commands Base Station Controller CML:BSC RUGRDL RUGRUL RUNAVGFCTSUBS RUNESU Upgrade threshold (9.6 kbit/s -> 14.4 kbit/s) for downlink direction. Validity range: rateUpgradeDownlink 0..5 <NULL> (default value: 1) For the values make references to Appendix B: Group 3. Contained in the following commands: GET HAND, SET HAND Upgrade threshold (9.6 kbit/s -> 14.4 kbit/s) for uplink direction. Validity range: rateUpgradeUplink 0..5 <NULL> (default value: 1) For the values make references to Appendix B: Group 3. Contained in the following commands: GET HAND, SET HAND This attribute determines the factor for running average filter. Validity range: runAvrgFactSubsec RUNAVG_00 RUNAVG_01 RUNAVG_02 RUNAVG_03 RUNAVG_04 RUNAVG_05 RUNAVG_06 RUNAVG_07 RUNAVG_08 RUNAVG_09 RUNAVG_10 <DEFAULT> (default value: RUNAVG_05) Contained in the following commands: CREATE SWIBEAM, GET SWIBEAM, SET SWIBEAM This read-only parameter defines the currently running ESU (Executable Software Unit). Validity range: runningESU pathname Contained in the following commands: GET BTSMOSUSW, GET BTSMTDOSUSW, GET BSCOSUDB, GET BSCOSUSW, GET TRAUOSUSW 1694 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller RXDLTSUBS RXLVR Switch to a different subsector antenna is only performed if the receive level of the new subsector is at least better than RXDLTSUBS. The step value is 0.5 dB. The range corresponds to 0.0 ... 5.0 dB (RXD_00 -> 0 dB, RXD_05 -> 0.5 dB, ..., RXD_50 -> 5 dB). Validity range: rxDeltaSubsec RXD_00 RXD_05 RXD_10 RXD_15 RXD_20 RXD_25 RXD_30 RXD_35 RXD_40 RXD_45 RXD_50 <DEFAULT> (default value: RXD_15) Contained in the following commands: CREATE SWIBEAM, GET SWIBEAM, SET SWIBEAM This parameter requires 7 input values which define the 8 ranges for RXLEVred (Input_value1, Input_value2....Input_value7); the input_values are defined by means of the "rangeBound<n> fields (<n>=1..7) of the RXLEV_RED parameter. The allowed input values for RXLEV are 0 to 63, as defined in GSM. The correspondence between the Input_values, RXLED_RED and RXLEV is the following: RXLEV_RED_Range0: RXLEV<= Inputvalue1 RXLEV_RED_Range1:Input_value1 <RXLEV<= Inputvalue2 RXLEV_RED_Range2:Input_value2 <RXLEV<= Inputvalue3 RXLEV_RED_Range3:Input_value3 <RXLEV<= Inputvalue4 RXLEV_RED_Range4:Input_value4 <RXLEV<= Inputvalue5 RXLEV_RED_Range5:Input_value5 <RXLEV<= Inputvalue6 RXLEV_RED_Range6:Input_value6 <RXLEV<= Inputvalue7 RXLEV_RED_Range6:Input_value6 <RXLEV Validity range: rxLevRanges rangeBound1 0..63 (default value = 7) rangeBound2 0..63 (default value = 15) rangeBound3 0..63 (default value = 23) rangeBound4 0..63 (default value = 31) rangeBound5 0..63 (default value = 39) rangeBound6 0..63 (default value = 47) rangeBound7 0..63 A30808-X3247-L230-3-7619 1695 Commands Base Station Controller CML:BSC RXLEVAMI RXLEVAMITD RXLEVHO RXLEVMIN (default value = 55) Contained in the following commands: CREATE SCANCTRX, GET SCANCTRX, SET SCANCTRX, This parameter is used in order to evaluate the path loss criterion parameter C1 of a cell. It indicates the minimumreceived level at the MS required for the access to the system. The value is an integer number in the range 0 to 63. Validity range: rxLevAccessMin 0..63 <DEFAULT> (default value: 6) For the values make reference to Appendix B: Group 2. Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter is used in order to evaluate the path loss criterion parameter C1 of a cell. It indicates the minimumreceived level at the MS required for the access to the system. The value is an integer number in the range 0 to 63. Validity range: rxLevAccessMin 0..63 <DEFAULT> (default value: 6) For the values make reference to Appendix B: Group 2. Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD. This attribute indicates whether handover due to uplink or downlink received low level is enabled or disabled. Validity range: enableRxLevHo FALSE TRUE (default value: TRUE) Contained in the following commands: SET HAND, GET HAND, GET HANDTD, SET HANDTD This attribute holds the minimumreceived signal strength in a cell for a MS to be handed over to that cell. It is the minimum RXLEV (Reception Level) required from an MS to perform the handover to adjacent cell "adjcn". This parameter is used in the handover preprocessing function. Validity range: rxLevMinCell 0..63 dBr (default value: 12 dBr) 1696 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller RXLEVMINC RXLEVMINTD RXLV For the values make references to Appendix B: Group 2. Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC This parameter determines the minimum received signal level the adjacent UMTS cell must provide to be regarded as suitable target cell for handover. The parameter is coded according to the following table: 0 RSCP < - 115 dBm 1 - 115 dBm <= RSCP < - 114 dBm ... ... 62 - 54 dBm <= RSCP < - 53 dBm 63 - 53 dBm <= RSCP Validity range: rxLevMinCell 0..63 (default value: 5 for FDD, 15 for TDD) Contained in the following commands: CREATE ADJC3G, GET ADJC3G, SET ADJC3G This attribute holds the minimum received signal strength in a TD- SCDMA cell for a UE to be handed over to that cell. It is the minimum reception level required from an UE to perform the handover to adja- cent cell "adjctdn". This parameter is used in the handover preprocessing function. Validity range: rxLevMinCellTD 0..63 dBr <NULL> (default value: 12 dBr) For the values make references to Appendix B: Group 2. Contained in the following commands: CREATE ADJCTD, GET ADJCTD, SET ADJCTD This attribute specifies above which level RXLEV values are taken into account. Validity range: rxLevel 1..62 <DEFAULT> (default value: 10) Contained in the following commands: CREATE RFLOOP, GET RFLOOP, SET RFLOOP A30808-X3247-L230-3-7619 1697 Commands Base Station Controller CML:BSC RXMSUBS RXPWRDES RXQUALHO RXSRS This attribute determines the quality threshold for best subsector selection. The step value is 0.5 dB. The range corresponds to 1.0 ... 10.0 dB (0 -> 1 dB, 1 -> 1.5 dB, ..., 18 -> 10 dB). Validity range: rxMarginSubsec 0..18 <DEFAULT> (default value: 4) Contained in the following commands: CREATE SWIBEAM, GET SWIBEAM, SET SWIBEAM This parameter defines the target value for the receive power at the UE (given in dBm). It is needed to determine the transmit power during handover . Validity range: rxPWRDes -120.0..-56.5 dBm (0.5 dBm step size) (default value: -110.5 dBm) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD. This attribute indicates whether handover due to bad uplink or downlink received quality is enabled or disabled. Validity range: enableRxQualHo FALSE TRUE (default value: TRUE) Contained in the following commands: GET HAND, SET HAND, GET HANDTD, SET HANDTD This attribute indicates the working formality of RX-switch. If set at periodical the RX-switch is toggled with the frequency defined by the RXTOattribute, otherwise RX-switch in both SDUAMCOs is statically switched to the required direction. Validity range: rxSwitchRequiredSetting PERIODICAL NORMAL DIVERSITY (default value: PERIODICAL) Contained in the following commands: CREATE SWIBEAM, GET SWIBEAM, SET SWIBEAM 1698 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller RXTH RXTO SALUNAME This attribute determines the threshold considered for calculating the TX direction. Values are expressed in dBm(MDB_80 -> - 80 dBm, ..., MDB_110 -> - 110 dBm, ..., MDB_120 -> - 120 dBm). Validity range: rxThresholdTXDirection MDB_80 MDB_81 MDB_82 MDB_83 MDB_84 MDB_85 MDB_86 MDB_87 MDB_88 MDB_89 MDB_90 MDB_91 MDB_92 MDB_93 MDB_94 MDB_95 MDB_96 MDB_97 MDB_98 MDB_99 MDB_100 MDB_101 MDB_102 MDB_103 MDB_104 MDB_105 MDB_106 MDB_107 MDB_108 MDB_109 MDB_110 MDB_111 MDB_112 MDB_113 MDB_114 MDB_115 MDB_116 MDB_117 MDB_118 MDB_119 MDB_120 <DEFAULT> (default value: MDB_110) Contained in the following commands: CREATE SWIBEAM, GET SWIBEAM, SET SWIBEAM This attribute determines whether the RX-switch is toggled after 1, 2, 4 or 8 TDMA frames. Validity range: rxToggleFrequency TDMA_FRAMES_1 TDMA_FRAMES_2 TDMA_FRAMES_4 TDMA_FRAMES_8 (default value: TDMA_FRAMES_2) Contained in the following commands: CREATE SWIBEAM, GET SWIBEAM, SET SWIBEAM This attribute defines every Network Element by its unique name. When it appears in the BTSMand TRAU commands, it is used during the network element alignment phase to verify its identity. Validity range: salesUniqueName 0..11 characters string <DEFAULT> A30808-X3247-L230-3-7619 1699 Commands Base Station Controller CML:BSC SANTIME SANUNIT SCCPCHDESC SCHWEIPRI1 (default value: NOT_DEFINED) Contained in the following commands: GET BSCE, SET BSCE, CREATE BTSM, GET BTSM, SET BTSM, CREATE BTSMTD, GET BTSMTD, SET BTSMTD CREATE TRAU, GET TRAU, SET TRAU Sanity timer to control the Level 2 Processor (PPCC) outage. Value 0 means timer disabled. Validity range: sanityTimer 0..255 hundreds of milliseconds (default value: 10) Contained in the following commands: CREATE OPC, GET OPC, SET OPC This read-only parameter defines the measurement unit for the SANTIME timer. Validity range: SanityUnit MS100 100 msec unit Contained in the following commands: GET OPC This parameter gives the channel physical description of S-CCPCH and defines the number of blocks reserved for AGCH, CBCH, other use ( e.g. NCH ). Validity range: sCCPCHDESC Items 0..1 (default value: 0) timeSlot 4..6 TSC 0..15 Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This field indicates the scheduling weight associated to scheduling priorities 1. Validity range: schedulingWeightOfPriority1 1..16 <DEFAULT> (default value: 8) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF 1700 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SCHWEIPRI2 SCHWEIPRI3 SCHWEIPRI4 SDCCHCONGTH SECONDARYIPADDR This field indicates the scheduling weight associated to scheduling priorities 2. Validity range: schedulingWeightOfPriority2 1..16 <DEFAULT> (default value: 4) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This field indicates the scheduling weight associated to scheduling priorities 3. Validity range: schedulingWeightOfPriority3 1..16 <DEFAULT> (default value: 2) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This field indicates the scheduling weight associated to scheduling priorities 4. Validity range: schedulingWeightOfPriority4 1..16 <DEFAULT> (default value: 1) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter represents the threshold which is set on a per cell basis and moves sub-channels from the TCHSDPOOL (see CHPOOLTYP parameter) to the SDCCH_BACKUP_POOL. Validity range: sdcchCongestionThreshold 70..100 <NULL> Contained in the following commands: CREATE BTS, GET BTS, SET BTS This attribute is the Ip address that is assigned to the standby MPCC port. The RC and CBC will never use this address when calling the BSC. It will be used in order to performthe periodical Ip link test. The convention used for this value is the well-known dotted decimal format (e.g. 172.31.21.88). Validity range: SecondaryIpAddress string 7..15 chars Contained in the following commands: CREATE IPLI, GET IPLI,SET IPLI A30808-X3247-L230-3-7619 1701 Commands Base Station Controller CML:BSC SG1HOPAR SG1PCPAR This attribute specifies the set of Handover parameters for Service Group 1. For the parameters make reference to Tab. 6.16 of Appendix B: Group 7. Validity range: sg1HandoverParms <DEFAULT> <NULL> hoLowerThresholdLevDL 0..63 hoLowerThresholdLevUL 0..63 hoThresholdLevDLintra 0..63 hoThresholdLevULintra 0..63 hoRxlevDLinner 0..63 hoRxlevDLouter 0..63 hoLowerThresholdQualDL 0..7 hoLowerThresholdQualUL 0..7 (default value: <NULL>) Contained in the following commands: GET HAND, SET HAND This attribute specifies the set of Power Control parameters for Service Group 1. For the parameters make reference to Tab. 6.20 of Appendix B: Group 7. Validity range: sg1PowerControlParms <DEFAULT> <NULL> EnableBSPowerControl DISABLED, CLASSIC, ADAPTIVE EnableMSPowerControl DISABLED, CLASSIC, ADAPTIVE EnablePowerControlRLFW TRUE, FALSE PcLowerThresholdLevDL 0..63 PcLowerThresholdLevUL 0..63 PcUpperThresholdLevDL 0..63 PcUpperThresholdLevUL 0..63 PcRLFThreshold 0..64 PcLowerThresholdQualDL 0..7 PcLowerThresholdQualUL 0..7 PcUpperThresholdQualDL 0..7 PcUpperThresholdQualUL 0..7 (default value: <NULL>) Contained in the following commands: GET PWRC, SET PWRC 1702 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SG2HOPAR SG2PCPAR This attribute specifies the set of Handover parameters for Service Group 2. For the parameters make reference to Tab. 6.16 of Appendix B: Group 7. Validity range: sg2HandoverParms <DEFAULT> <NULL> hoLowerThresholdLevDL 0..63 hoLowerThresholdLevUL 0..63 hoThresholdLevDLintra 0..63 hoThresholdLevULintra 0..63 hoRxlevDLinner 0..63 hoRxlevDLouter 0..63 hoLowerThresholdQualDL 0..7 hoLowerThresholdQualUL 0..7 (default value: <NULL>) Contained in the following commands: GET HAND, SET HAND This attribute specifies the set of Power Control parameters for Service Group 2. For the parameters make reference to Tab. 6.20 of Appendix B: Group 7. Validity range: sg2PowerControlParms <DEFAULT> <NULL> EnableBSPowerControl DISABLED, CLASSIC, ADAPTIVE EnableMSPowerControl DISABLED, CLASSIC, ADAPTIVE EnablePowerControlRLFW TRUE, FALSE PcLowerThresholdLevDL 0..63 PcLowerThresholdLevUL 0..63 PcUpperThresholdLevDL 0..63 PcUpperThresholdLevUL 0..63 PcRLFThreshold 0..64 PcLowerThresholdQualDL 0..7 PcLowerThresholdQualUL 0..7 PcUpperThresholdQualDL 0..7 PcUpperThresholdQualUL 0..7 (default value: <NULL>) Contained in the following commands: GET PWRC, SET PWRC A30808-X3247-L230-3-7619 1703 Commands Base Station Controller CML:BSC SG3HOPAR SG3PCPAR This attribute specifies the set of Handover parameters for Service Group 3. For the parameters make reference to Tab. 6.16 of Appendix B: Group 7. Validity range: sg3HandoverParms <DEFAULT> <NULL> hoLowerThresholdLevDL 0..63 hoLowerThresholdLevUL 0..63 hoThresholdLevDLintra 0..63 hoThresholdLevULintra 0..63 hoRxlevDLinner 0..63 hoRxlevDLouter 0..63 hoLowerThresholdQualDL 0..7 hoLowerThresholdQualUL 0..7 (default value: <NULL>) Contained in the following commands: GET HAND, SET HAND This attribute specifies the set of Power Control parameters for Service Group 3. For the parameters make reference to Tab. 6.20 of Appendix B: Group 7. Validity range: sg3PowerControlParms <DEFAULT> <NULL> EnableBSPowerControl DISABLED, CLASSIC, ADAPTIVE EnableMSPowerControl DISABLED, CLASSIC, ADAPTIVE EnablePowerControlRLFW TRUE, FALSE PcLowerThresholdLevDL 0..63 PcLowerThresholdLevUL 0..63 PcUpperThresholdLevDL 0..63 PcUpperThresholdLevUL 0..63 PcRLFThreshold 0..64 PcLowerThresholdQualDL 0..7 PcLowerThresholdQualUL 0..7 PcUpperThresholdQualDL 0..7 PcUpperThresholdQualUL 0..7 (default value: <NULL>) Contained in the following commands: GET PWRC, SET PWRC 1704 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SG4HOPAR SG4PCPAR This attribute specifies the set of Handover parameters for Service Group 4. For the parameters make reference to Tab. 6.16 of Appendix B: Group 7. Validity range: sg4HandoverParms <DEFAULT> <NULL> hoLowerThresholdLevDL 0..63 hoLowerThresholdLevUL 0..63 hoThresholdLevDLintra 0..63 hoThresholdLevULintra 0..63 hoRxlevDLinner 0..63 hoRxlevDLouter 0..63 hoLowerThresholdQualDL 0..7 hoLowerThresholdQualUL 0..7 (default value: <NULL>) Contained in the following commands: GET HAND, SET HAND This attribute specifies the set of Power Control parameters for Service Group 4. For the parameters make reference to Tab. 6.20 of Appendix B: Group 7. Validity range: sg4PowerControlParms <DEFAULT> <NULL> EnableBSPowerControl DISABLED, CLASSIC, ADAPTIVE EnableMSPowerControl DISABLED, CLASSIC, ADAPTIVE EnablePowerControlRLFW TRUE, FALSE PcLowerThresholdLevDL 0..63 PcLowerThresholdLevUL 0..63 PcUpperThresholdLevDL 0..63 PcUpperThresholdLevUL 0..63 PcRLFThreshold 0..64 PcLowerThresholdQualDL 0..7 PcLowerThresholdQualUL 0..7 PcUpperThresholdQualDL 0..7 PcUpperThresholdQualUL 0..7 (default value: <NULL>) Contained in the following commands: GET PWRC, SET PWRC A30808-X3247-L230-3-7619 1705 Commands Base Station Controller CML:BSC SG5HOPAR SG5PCPAR This attribute specifies the set of Handover parameters for Service Group 5. For the parameters make reference to Tab. 6.16 of Appendix B: Group 7. Validity range: sg5HandoverParms <DEFAULT> <NULL> hoLowerThresholdLevDL 0..63 hoLowerThresholdLevUL 0..63 hoThresholdLevDLintra 0..63 hoThresholdLevULintra 0..63 hoRxlevDLinner 0..63 hoRxlevDLouter 0..63 hoLowerThresholdQualDL 0..7 hoLowerThresholdQualUL 0..7 (default value: <NULL>) Contained in the following commands: GET HAND, SET HAND This attribute specifies the set of Power Control parameters for Service Group 5. For the parameters make reference to Tab. 6.20 of Appendix B: Group 7. Validity range: sg5PowerControlParms <DEFAULT> <NULL> EnableBSPowerControl DISABLED, CLASSIC, ADAPTIVE EnableMSPowerControl DISABLED, CLASSIC, ADAPTIVE EnablePowerControlRLFW TRUE, FALSE PcLowerThresholdLevDL 0..63 PcLowerThresholdLevUL 0..63 PcUpperThresholdLevDL 0..63 PcUpperThresholdLevUL 0..63 PcRLFThreshold 0..64 PcLowerThresholdQualDL 0..7 PcLowerThresholdQualUL 0..7 PcUpperThresholdQualDL 0..7 PcUpperThresholdQualUL 0..7 (default value: <NULL>) Contained in the following commands: GET PWRC, SET PWRC 1706 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SG6HOPAR SG6PCPAR This attribute specifies the set of Handover parameters for Service Group 6. For the parameters make reference to Tab. 6.16 of Appendix B: Group 7. Validity range: sg6HandoverParms <DEFAULT> <NULL> hoLowerThresholdLevDL 0..63 hoLowerThresholdLevUL 0..63 hoThresholdLevDLintra 0..63 hoThresholdLevULintra 0..63 hoRxlevDLinner 0..63 hoRxlevDLouter 0..63 hoLowerThresholdQualDL 0..7 hoLowerThresholdQualUL 0..7 (default value: <NULL>) Contained in the following commands: GET HAND, SET HAND This attribute specifies the set of Power Control parameters for Service Group 6. For the parameters make reference to Tab. 6.20 of Appendix B: Group 7. Validity range: sg6PowerControlParms <DEFAULT> <NULL> EnableBSPowerControl DISABLED, CLASSIC, ADAPTIVE EnableMSPowerControl DISABLED, CLASSIC, ADAPTIVE EnablePowerControlRLFW TRUE, FALSE PcLowerThresholdLevDL 0..63 PcLowerThresholdLevUL 0..63 PcUpperThresholdLevDL 0..63 PcUpperThresholdLevUL 0..63 PcRLFThreshold 0..64 PcLowerThresholdQualDL 0..7 PcLowerThresholdQualUL 0..7 PcUpperThresholdQualDL 0..7 PcUpperThresholdQualUL 0..7 (default value: <NULL>) Contained in the following commands: GET PWRC, SET PWRC A30808-X3247-L230-3-7619 1707 Commands Base Station Controller CML:BSC SG7HOPAR SG7PCPAR This attribute specifies the set of Handover parameters for Service Group 7. For the parameters make reference to Tab. 6.17 of Appendix B: Group 7. Validity range: sg7HandoverParms <DEFAULT> <NULL> hoLowerThresholdLevDL 0..63 hoLowerThresholdLevUL 0..63 hoThresholdLevDLintra 0..63 hoThresholdLevULintra 0..63 hoRxlevDLinner 0..63 hoRxlevDLouter 0..63 hoLowerThresholdQualDL 0..7 hoLowerThresholdQualUL 0..7 rateHoLowerThresholdQualDL 2..7 rateHoLowerThresholdQualUL 2..7 (default value: <NULL>) Contained in the following commands: GET HAND, SET HAND This attribute specifies the set of Power Control parameters for Service Group 7. For the parameters make reference to Tab. 6.20 of Appendix B: Group 7. Validity range: sg7PowerControlParms <DEFAULT> <NULL> EnableBSPowerControl DISABLED, CLASSIC, ADAPTIVE EnableMSPowerControl DISABLED, CLASSIC, ADAPTIVE EnablePowerControlRLFW TRUE, FALSE PcLowerThresholdLevDL 0..63 PcLowerThresholdLevUL 0..63 PcUpperThresholdLevDL 0..63 PcUpperThresholdLevUL 0..63 PcRLFThreshold 0..64 PcLowerThresholdQualDL 0..7 PcLowerThresholdQualUL 0..7 PcUpperThresholdQualDL 0..7 PcUpperThresholdQualUL 0..7 (default value: <NULL>) Contained in the following commands: GET PWRC, SET PWRC 1708 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SG8HOPAR SG8PCPAR This attribute specifies the set of Handover parameters for Service Group 8. For the parameters make reference to Tab. 6.17 of Appendix B: Group 7. Validity range: sg8HandoverParms <DEFAULT> <NULL> hoLowerThresholdLevDL 0..63 hoLowerThresholdLevUL 0..63 hoThresholdLevDLintra 0..63 hoThresholdLevULintra 0..63 hoRxlevDLinner 0..63 hoRxlevDLouter 0..63 hoLowerThresholdQualDL 0..7 hoLowerThresholdQualUL 0..7 rateHoLowerThresholdQualDL 2..7 rateHoLowerThresholdQualUL 2..7 (default value: <NULL>) Contained in the following commands: GET HAND, SET HAND This attribute specifies the set of Power Control parameters for Service Group 8. For the parameters make reference to Tab. 6.20 of Appendix B: Group 7. Validity range: sg8PowerControlParms <DEFAULT> <NULL> EnableBSPowerControl DISABLED, CLASSIC, ADAPTIVE EnableMSPowerControl DISABLED, CLASSIC, ADAPTIVE EnablePowerControlRLFW TRUE, FALSE PcLowerThresholdLevDL 0..63 PcLowerThresholdLevUL 0..63 PcUpperThresholdLevDL 0..63 PcUpperThresholdLevUL 0..63 PcRLFThreshold 0..64 PcLowerThresholdQualDL 0..7 PcLowerThresholdQualUL 0..7 PcUpperThresholdQualDL 0..7 PcUpperThresholdQualUL 0..7 (default value: <NULL>) Contained in the following commands: GET PWRC, SET PWRC A30808-X3247-L230-3-7619 1709 Commands Base Station Controller CML:BSC SG9HOPAR SG9PCPAR This attribute specifies the set of Handover parameters for Service Group 9. For the parameters make reference to Tab. 6.17 of Appendix B: Group 7. Validity range: sg9HandoverParms <DEFAULT> <NULL> hoLowerThresholdLevDL 0..63 hoLowerThresholdLevUL 0..63 hoThresholdLevDLintra 0..63 hoThresholdLevULintra 0..63 hoRxlevDLinner 0..63 hoRxlevDLouter 0..63 hoLowerThresholdQualDL 0..7 hoLowerThresholdQualUL 0..7 rateHoLowerThresholdQualDL 2..7 rateHoLowerThresholdQualUL 2..7 (default value: <NULL>) Contained in the following commands: GET HAND, SET HAND This attribute specifies the set of Power Control parameters for Service Group 9. For the parameters make reference to Tab. 6.20 of Appendix B: Group 7. Validity range: sg9PowerControlParms <DEFAULT> <NULL> EnableBSPowerControl DISABLED, CLASSIC, ADAPTIVE EnableMSPowerControl DISABLED, CLASSIC, ADAPTIVE EnablePowerControlRLFW TRUE, FALSE PcLowerThresholdLevDL 0..63 PcLowerThresholdLevUL 0..63 PcUpperThresholdLevDL 0..63 PcUpperThresholdLevUL 0..63 PcRLFThreshold 0..64 PcLowerThresholdQualDL 0..7 PcLowerThresholdQualUL 0..7 PcUpperThresholdQualDL 0..7 PcUpperThresholdQualUL 0..7 (default value: <NULL>) Contained in the following commands: GET PWRC, SET PWRC 1710 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SG10HOPAR SG10PCPAR This attribute specifies the set of Handover parameters for Service Group 10. For the parameters make reference to Tab. 6.17 of Appendix B: Group 7. Validity range: sg10HandoverParms <DEFAULT> <NULL> hoLowerThresholdLevDL 0..63 hoLowerThresholdLevUL 0..63 hoThresholdLevDLintra 0..63 hoThresholdLevULintra 0..63 hoRxlevDLinner 0..63 hoRxlevDLouter 0..63 hoLowerThresholdQualDL 0..7 hoLowerThresholdQualUL 0..7 rateHoLowerThresholdQualDL 2..7 rateHoLowerThresholdQualUL 2..7 (default value: <NULL>) Contained in the following commands: GET HAND, SET HAND This attribute specifies the set of Power Control parameters for Service Group 10. For the parameters make reference to Tab. 6.20 of Appendix B: Group 7. Validity range: sg10PowerControlParms <DEFAULT> <NULL> EnableBSPowerControl DISABLED, CLASSIC, ADAPTIVE EnableMSPowerControl DISABLED, CLASSIC, ADAPTIVE EnablePowerControlRLFW TRUE, FALSE PcLowerThresholdLevDL 0..63 PcLowerThresholdLevUL 0..63 PcUpperThresholdLevDL 0..63 PcUpperThresholdLevUL 0..63 PcRLFThreshold 0..64 PcLowerThresholdQualDL 0..7 PcLowerThresholdQualUL 0..7 PcUpperThresholdQualDL 0..7 PcUpperThresholdQualUL 0..7 (default value: <NULL>) Contained in the following commands: GET PWRC, SET PWRC A30808-X3247-L230-3-7619 1711 Commands Base Station Controller CML:BSC SG11HOPAR SG11PCPAR This attribute specifies the set of Handover parameters for Service Group 11. For the parameters make reference to Tab. 6.18 of Appendix B: Group 7. Validity range: sg11HandoverParms <DEFAULT> <NULL> hoLowerThresholdLevDL 0..63 hoLowerThresholdLevUL 0..63 hoThresholdLevDLintra 0..63 hoThresholdLevULintra 0..63 hoRxlevDLinner 0..63 hoRxlevDLouter 0..63 hoLowerThresQualAMRDL 0..30 hoLowerThresQualAMRUL 0..30 hoThresAMRComprDL 0..30 hoThresAMRComprUL 0..30 (default value: <NULL>) Contained in the following commands: GET HAND, SET HAND This attribute specifies the set of Power Control parameters for Service Group 11. For the parameters make reference to Tab. 6.21 of Appendix B: Group 7. Validity range: sg11PowerControlParms <DEFAULT> <NULL> EnableBSPowerControl DISABLED, CLASSIC, ADAPTIVE EnableMSPowerControl DISABLED, CLASSIC, ADAPTIVE EnablePowerControlRLFW TRUE, FALSE PcLowerThresholdLevDL 0..63 PcLowerThresholdLevUL 0..63 PcUpperThresholdLevDL 0..63 PcUpperThresholdLevUL 0..63 PcRLFThreshold 0..64 PcLowerThresQualAMRDL 0..30 PcLowerThresQualAMRUL 0..30 PcUpperThresQualAMRDL 0..30 PcUpperThresQualAMRUL 0..30 (default value: <NULL>) Contained in the following commands: GET PWRC, SET PWRC 1712 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SG12HOPAR SG12PCPAR This attribute specifies the set of Handover parameters for Service Group 12. For the parameters make reference to Tab. 6.18 of Appendix B: Group 7. Validity range: sg12HandoverParms <DEFAULT> <NULL> hoLowerThresholdLevDL 0..63 hoLowerThresholdLevUL 0..63 hoThresholdLevDLintra 0..63 hoThresholdLevULintra 0..63 hoRxlevDLinner 0..63 hoRxlevDLouter 0..63 hoLowerThresQualAMRDL 0..30 hoLowerThresQualAMRUL 0..30 hoThresAMRComprDL 0..30 hoThresAMRComprUL 0..30 (default value: <NULL>) Contained in the following commands: GET HAND, SET HAND This attribute specifies the set of Power Control parameters for Service Group 12. For the parameters make reference to Tab. 6.21 of Appendix B: Group 7. Validity range: sg12PowerControlParms <DEFAULT> <NULL> EnableBSPowerControl DISABLED, CLASSIC, ADAPTIVE EnableMSPowerControl DISABLED, CLASSIC, ADAPTIVE EnablePowerControlRLFW TRUE, FALSE PcLowerThresholdLevDL 0..63 PcLowerThresholdLevUL 0..63 PcUpperThresholdLevDL 0..63 PcUpperThresholdLevUL 0..63 PcRLFThreshold 0..64 PcLowerThresQualAMRDL 0..30 PcLowerThresQualAMRUL 0..30 PcUpperThresQualAMRDL 0..30 PcUpperThresQualAMRUL 0..30 (default value: <NULL>) Contained in the following commands: GET PWRC, SET PWRC A30808-X3247-L230-3-7619 1713 Commands Base Station Controller CML:BSC SG13HOPAR SG13PCPAR This attribute specifies the set of Handover parameters for Service Group 13. For the parameters make reference to Tab. 6.19 of Appendix B: Group 7. Validity range: sg13HandoverParms <DEFAULT> <NULL> hoLowerThresholdLevDL 0..63 hoLowerThresholdLevUL 0..63 hoThresholdLevDLintra 0..63 hoThresholdLevULintra 0..63 hoRxlevDLinner 0..63 hoRxlevDLouter 0..63 hoLowerThresQualAMRDL 0..30 hoLowerThresQualAMRUL 0..30 hoThreshAMRDecomprDL 0..30 hoThreshAMRDecomprUL 0..30 (default value: <NULL>) Contained in the following commands: GET HAND, SET HAND This attribute specifies the set of Power Control parameters for Service Group 13. For the parameters make reference to Tab. 6.21 of Appendix B: Group 7. Validity range: sg13PowerControlParms <DEFAULT> <NULL> EnableBSPowerControl DISABLED, CLASSIC, ADAPTIVE EnableMSPowerControl DISABLED, CLASSIC, ADAPTIVE EnablePowerControlRLFW TRUE, FALSE PcLowerThresholdLevDL 0..63 PcLowerThresholdLevUL 0..63 PcUpperThresholdLevDL 0..63 PcUpperThresholdLevUL 0..63 PcRLFThreshold 0..64 PcLowerThresQualAMRDL 0..30 PcLowerThresQualAMRUL 0..30 PcUpperThresQualAMRDL 0..30 PcUpperThresQualAMRUL 0..30 (default value: <NULL>) Contained in the following commands: GET PWRC, SET PWRC 1714 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SG14HOPAR SG14PCPAR This attribute specifies the set of Handover parameters for Service Group 14. For the parameters make reference to Tab. 6.19 of Appendix B: Group 7. Validity range: sg14HandoverParms <DEFAULT> <NULL> hoLowerThresholdLevDL 0..63 hoLowerThresholdLevUL 0..63 hoThresholdLevDLintra 0..63 hoThresholdLevULintra 0..63 hoRxlevDLinner 0..63 hoRxlevDLouter 0..63 hoLowerThresQualAMRDL 0..30 hoLowerThresQualAMRUL 0..30 hoThreshAMRDecomprDL 0..30 hoThreshAMRDecomprUL 0..30 (default value: <NULL>) Contained in the following commands: GET HAND, SET HAND This attribute specifies the set of Power Control parameters for Service Group 14. For the parameters make reference to Tab. 6.21 of Appendix B: Group 7. Validity range: sg14PowerControlParms <DEFAULT> <NULL> EnableBSPowerControl DISABLED, CLASSIC, ADAPTIVE EnableMSPowerControl DISABLED, CLASSIC, ADAPTIVE EnablePowerControlRLFW TRUE, FALSE PcLowerThresholdLevDL 0..63 PcLowerThresholdLevUL 0..63 PcUpperThresholdLevDL 0..63 PcUpperThresholdLevUL 0..63 PcRLFThreshold 0..64 PcLowerThresQualAMRDL 0..30 PcLowerThresQualAMRUL 0..30 PcUpperThresQualAMRDL 0..30 PcUpperThresQualAMRUL 0..30 (default value: <NULL>) Contained in the following commands: GET PWRC, SET PWRC A30808-X3247-L230-3-7619 1715 Commands Base Station Controller CML:BSC SHLAPDIT SIMSCREL99 SISGSNREL99 SLAPDOVLTH This parameter is used by the BTSE to calculate the value of timer T202 which is used for the TEI assignment procedure. Validity range: shortLapdIntTimer 3..20 (1 sec step size) <DEFAULT> (default value: 15) Contained in the following commands: CREATE BTSM, GET BTSM, SET BTSM, CREATE BTSMTD, GET BTSMTD, SET BTSMTD When the value of this attribute changes the system information 3 is updated and resent on all cells belonging to the BSC to inform MSs about MSC release. This new procedure is allowed only with release 99 or onwards MSC. Validity range: systemInfoMscRel99 TRUE FALSE <DEFAULT> (default value: FALSE) Contained in the following commands: GET BSC, SET BSC This attribute is used to informMS about SGSNcapabilities. Possible values are: FALSE, i.e. SGSN is aligned to a version earlier than Release 99; TRUE, i.e. SGSN is aligned to Release 99 version. Validity range: systemInfoSgsnRelease99 TRUE FALSE <DEFAULT> (default value: FALSE) Contained in the following commands: GET BSC, SET BSC This attribute indicates the second level thresholds (in percentage) of the BTSE Radio Signalling links (LPDLRs). It consists of two fields: secondLevelUpperThreshold if the signalling traffic overcomes this threshold the BTSE starts periodic sending LAPD overload message. secondLevelLowerThreshold if the signalling traffic falls below this threshold the BTSE stops periodic sending LAPD overload message. Validity range: secondLapdOverloadThreshold <NULL> secondLevelUpperThreshold 10..100 (default value: 90) 1716 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SLC SLOWBFTH SLOWPCTH secondLevelLowerThreshold 10..100 (default value: 80) Contained in the following commands: CREATE BTSM, GET BTSM, SET BTSM, CREATE BTSMTD, GET BTSMTD, SET BTSMTD The Signalling Link Code is a logical number which identifies the signalling link. Validity range: signallingLinkCode 0..15 Contained in the following commands: CREATE SS7L, GET SS7L This parameter defines the slow Beamforming Threshold (BFT). For each frame the biggest eigenvalue is measured; if the biggest eigenvalue of consecutive frames is correlated very lightly, i.e. the correlation is above slowBFThreshold, the biggest eigenvalue changes originating from slow fading cannot be forecasted and the slow beamforming is switched off totally. Validity range: slowBFThreshold N_<nn>_16 <nn>=00 to 16 <DEFAULT> (defualt value: N_13_16) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD The SLOWPCTH parameter defines the Slow PowerControl threshold. For each frame the SIR (Signal-to-Interference Ratio) is measured. If the SIR of consecutive frames is correlated very lightly,i.e.the correlation is above SLOWPCTH, the SIR changes orig- inating from slow fading cannot be forecasted and the slow power control is switched off totally. Validity range: slowPCThreshold N_<nn>_16 <nn>=00 to 16 <DEFAULT> (default value: N_12_16) Contained in the following commands: GET PWRCTD, SET PWRCTD A30808-X3247-L230-3-7619 1717 Commands Base Station Controller CML:BSC SLOWSCTH SMSCBUSE SMLCPERTFLAG SMLCSPC The SLOWSCTH parameter defines the Slow Synchronisation Control Threshold. For each frame the signal delay is measured; if the delay of consecutive frames is correlated very lightly, i.e. the correla- tion is above SLOWSCTH, the delay changes originating from slow fading cannot be forecasted and the slow synchronisation control is switched off totally. Validity range: slowSCThreshold N_<nn>_16 <nn>=00 to 16 <DEFAULT> (default value: N_12_16) Contained in the following commands: GET PWRCTD, SET PWRCTD This attribute indicates if the Short Message Service Cell Broadcast is enabled or disabled. Validity range: smsCBUsed FALSE, TRUE, <DEFAULT> (default value: FALSE) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD This attribute represents the flag to enable the periodic test towards SMLC (SLT procedure). Validity range: sMLCPeriocTestFlag TRUE FALSE <DEFAULT> (default value: TRUE) Contained in the following commands: CREATE OPC, GET OPC, SET OPC This attribute identifies the Signalling Point Code (SPC) of the SMLC (Serving Mobile Location Center). It consists of three fields: networkClusterMember, networkCluster and networkIdentifier; the first two fields are mandatory while the third field is optional. Validity range: sMLCSignallingPointCode <NULL> networkClusterMember 0..255 0..255 for CCITT 1..255 for ANSI networkCluster 0..255 0..63 for CCITT 0..255 for ANSI networkIdentifier 1..254 1..254 for ANSI NO_CONFIG for CCITT 1718 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SNRIMPRETH SOURCE SPEED145 SPENLAW (default value: <NULL>) Contained in the following commands: CREATE OPC, GET OPC, SET OPC This parameter defines the SNR (Signal-to-Noise Ratio) threshold which is used to determine the start and end position of channel impulse response. Validity range: snrOfImpulseRespThres 0.0..8.0 dB (0.5 dB step size) <DEFAULT> (default value: 5.0 dB) Contained in the following commands: This attribute identifies the source from which the MPCC executable file is loaded. Validity range: source SYS_FALLBACK LMT Contained in the following commands: LOADMPCC This attribute controls the 14.4 kbit/s data service activation. Validity range: speedSupported_14_5 FALSE TRUE (default value: FALSE) Contained in the following commands: GET BSC, SET BSC This attribute specifies the type of G.711 speech encoding law used. Validity range: speechEncodingLaw A_LAW U_LAW (default value: 0) Contained in the following commands: GET BSC, SET BSC A30808-X3247-L230-3-7619 1719 Commands Base Station Controller CML:BSC SRCDIR SRCFILE SRCPATH SRCPATHNAME This parameter specifies the name of the directory on the BSC disk or LMT disk which the file has to be transferred from. The user can use the Browse Dir button to select the directory on the LMT disk; this button is not available for the FILEHANDLER object commands and for the UPLFILE command. For the DNLIDFD command, this parameter specifies the source directory where the BSC_NRIU file is stored. Validity range: sourceDirectory 0..80 characters string For FILEHANDLER object: 1..45 characters string Contained in the following commands: DNLIDFD REMINV, FILECOM FILEHANDLER, FILEDECOM FILE- HANDLER, UPLFILE This attribute defines the name of the compressed file. Validity range: sourceFile 1..13 characters strings Contained in the following commands: FILEDECOM FILEHANDLER This parameter represents the source path of the files which are copied. It consists of two fields divided by \ symbol: the first file is the path while the second field represents the file name; the user can use the Browse File Path button to select the directory on the LMT disk. Validity range: relatedFiles 1..79 characters string \ 1..12 characters string for the LOADMPCC command; 1..79 characters string \ 1..60 for all the other commands Contained in the following commands: LOADMPCC, CREATE RSUDB, CREATE RSUEXE, CREATE RSUPCH, CREATE RSUSWLH This parameter represents the source path of the files which are to be copied or moved. Validity range: sourcePathName 1..59 characters string Contained in the following commands: COPY FILEHANDLER, MOVE FILEHANDLER 1720 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SS7MTPTYP SSUPPTS START This attribute indicates the type of link at the A interface (ANSI or CCITT). Validity range: ss7MtpType CCITT ANSI (default value: CCITT) Contained in the following commands: CREATE OPC, GET OPC A UE executing the immediate assignment procedure repeats the transmission of the SYNC1 message if it received no answer fromthe network in a given time. The parameter SSUPPTS defines of howmuch the UE shall increase transmission power at each SYNC1 burst repetition. Validity range: stepSizeUpPTS NO_CHANGE INCR_BY_1DB INCR_BY_2DB INCR_BY_3DB <DEFAULT> (default value: INCR_BY_1DB) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter represents the starting day of the collecting activity for the scanner or SCA instance; it consists of three fields: day, month and year. Validity range: day 1..31 (default value = 1) month january..december (default value = january) year 1992..2099 (default value = 1995) Contained in the following commands: CREATE CTRSCHED, GET CTRSCHED, SET CTRSCHED, CREATE RFLOOP, GET RFLOOP, SET RFLOOP, CREATE SCA, GET SCA, SET SCA, CREATE SCANAIRTSTD, GET SCANAIRTSTD, SET SCANAIRTSTD, CREATE SCANBSC, GET SCANBSC, SET SCANBSC, CREATE SCANBTS, GET SCANBTS, SET SCANBTS, CREATE SCANBTSABISTD, GET SCANBT- SABISTD, SET SCANBTSABISTD, CREATE SCANBTSE, GET SCANBTSE, SET SCANBTSE, CREATE SCANBTSM, GET SCAN- BTSM, SET SCANBTSM, CREATE SCANBTSMTD, GETSCAN- BTSMTD, SET SCANBTSMTD, CREATE SCANBTSIHO, GET SCANBTSIHO, SET SCANBTSIHO, A30808-X3247-L230-3-7619 1721 Commands Base Station Controller CML:BSC STATSUBS STGTTLLIINF CREATE SCANBTSOHOI, GET SCANBTSOHOI, SET SCANBTSOHOI, CREATE SCANBTSOHON, GET SCANBTSOHON, SET SCANBTSOHON, CREATE SCANBTSOHOS, SET SCANBTSOHOS, CREATE SCANBTSTD, GET SCANBTSTD, SET SCANBTSTD, CREATE SCANBTSTDIHDO, GET SCANBTSTDIHDO, SET SCAN- BTSTDIHDO, CREATE SCANBTSTDOHDOI, GET SCANBTST- DOHDOI, CREATE SCANBTSTDOHDOI,CREATE SCANBTSTDOHDON, GET SCANBTSTDOHON, SET SCANBTST- DOHDON, CREATE SCANCHAN, GET SCANCHAN, SET SCAN- CHAN, CREATE SCANCTRX, GET SCANCTRX, SET SCANCTRX, CREATE SCANFBTSM, GET SCANFBTSM, SET SCANFBTSM, CREATE SCANGPRS, GET SCANGPRS, SET SCANGPRS, CREATE SCANGPRSTD, GET SCANGPRSTD, SET SCANG- PRSTD, CREATE SCANSS7L, GET SCANSS7L, SET SCANSS7L, CREATE SCANTRX, GET SCANTRX, SET SCANTRX CREATE SCANTRXABISTD, GET SCANTRXABISTD, SET SCANTRX- ABISTD, CREATE SCANTRXTD, GET SCANTRXTD, SET SCANT- RXTD Subsector antennas are not used until this timer has elapsed. Validity range: startTimerSubsec 1..20 (measurement reporting period unit) <DEFAULT> (default value: 2) Contained in the following commands: CREATE SWIBEAM, GET SWIBEAM, SET SWIBEAM This attribute indicates the time (in seconds) for which the BSCstores the information about TLLI (last used coding scheme and BLER) after the end of each TBF for that TLLI. Validity range: storageTimeTLLIInfo 10..90 (default value: 10) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF 1722 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller STOP SUBNETMASK This parameter represents the last day of the collecting activity for the scanner or SCA instance; it consists of three fields: day, month and year. Validity range: day 1..31 (default value = 31) month january..december (default value = december) year 1992..2099 (default value = 2099) Contained in the following commands: CREATE CTRSCHED, GET CTRSCHED, SET CTRSCHED, CREATE RFLOOP, GET RFLOOP, SET RFLOOP, CREATE SCA, GET SCA, SET SCA, CREATE SCANAIRTSTD, GET SCANAIRTSTD, SET SCANAIRTSTD, CREATE SCANBSC, GET SCANBSC, SET SCANBSC, CREATE SCANBTS, GET SCANBTS, SET SCANBTS, CREATE SCANBTSABISTD, GET SCANBTSABISTD, SET SCANBTSABISTD, CREATE SCANBTSE, GET SCANBTSE, SET SCANBTSE, CREATE SCANBTSIHO, GET SCANBTSIHO, SET SCANBTSIHO, CREATE SCANBTSM, GET SCANBTSM, CREATE SCANBTSMTD, GETSCANBTSMTD, SET SCANBTSMTD, SET SCANBTSM, CREATE SCANBTSOHOI, GET SCANBTSOHOI, SET SCANBTSOHOI, CREATE SCANBTSOHON, GET SCANBTSOHON, SET SCANBTSOHON, CREATE SCANBTSOHOS, SET SCANBTSOHOS, CREATE SCAN- BTSTD, GET SCANBTSTD, SET SCANBTSTD, CREATE SCANBT- STDIHDO, GET SCANBTSTDIHDO, SET SCANBTSTDIHDO, CREATE SCANBTSTDOHDOI, GET SCANBTSTDOHDOI, CREATE SCANBTSTDOHDOI,CREATE SCANBTSTDOHDON, GET SCANBTSTDOHON, SET SCANBTSTDOHDON, CREATE SCANCHAN, GET SCANCHAN, SET SCANCHAN, CREATE SCANCTRX, GET SCANCTRX, SET SCANCTRX, CREATE SCANFBTSM, GET SCANFBTSM, SET SCANFBTSM, CREATE SCANGPRS, GET SCANGPRS, SET SCANGPRS CREATE SCANGPRSTD, GET SCANGPRSTD, SET SCANG- PRSTD, CREATE SCANSS7L, GET SCANSS7L, SET SCANSS7L, CREATE SCANTRX, GET SCANTRX, SET SCANTRX, CREATE SCANTRXABISTD, GET SCANTRXABISTD, SET SCANTRX- ABISTD, CREATE SCANTRXTD, GET SCANTRXTD, SET SCANT- RXTD This attribute is the NetMask that is assigned to both the MPCC port copies. The value must be assigned according to the local LAN configuration. The convention used for this value is the well-known dotted decimal format (e.g. 255.255.255.0). Validity range: A30808-X3247-L230-3-7619 1723 Commands Base Station Controller CML:BSC SYNC1LDAVS SYNCHRO SYSID SubnetMask string 7..15 chars Contained in the following commands: CREATE IPLI, GET IPLI,SET IPLI This parameter defines the number of SYNC1 bursts over which SYNC1 measurements are performed. Since there are 8 possible SYNC1 bursts per frame, the step size is 8; a change of the attribute becomes effective immediately. Validity range: sync1LoadAverSlots 96..65520 (8 step size) <DEFAULT> (default value: 192) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD. This attribute sets scripts execution mode: in synchronous scripts, each command is not executed until the previous one has been replied by the Network Element; in asynchronous scripts, all commands are sent at once. Validity range: synchro YES, NO Contained in the following commands: SET, EXEC; It indicates the frequency band used by the cell. Validity range: systemIndicator BB900 (GSM Standard Band) DCS1800 F2ONLY900 (GSM Extended Band) EXT900 (GSM Mixed Band) PCS1900 GSMR (Railway Band) GSMDCS GSM850 GSM850PCS GSM850DCS Contained in the following commands: CREATE BTS, GET BTS, CREATE TGTBTS, GET TGTBTS, SET TGTBTS 1724 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller T1 T1TMUNIT T1UNIT1 T1UNIT This parameter identifies the Timer T1. For PCU, this timer defines the waiting time for BVCI block/unblock procedure; after a BVCI block/unblock message sent, the PCU waits T1 seconds for acknowledge. Validity range: t1 for X25A and X25D: 1..3000 (100 ms unit) <DEFAULT> (default value: 80) for PCU: 2..29 s <DEFAULT> (default value: 10 s) Contained in the following commands: CREATE PCU, GET PCU, SET PCU, CREATE PCUTD, GET PCUTD, SET PCUTD CREATE X25A, GET X25A, SET X25A, CREATE X25D, GET X25D, SET X25D This read-only parameter defines the measurement unit for the M3T1TM timer. Validity range: t1tmUnit MS100 100 msec unit Contained in the following commands: GET OPC This read-only parameter defines the measurement unit for the M3T1 timer. Validity range: t1Unit1 MS100 100 msec unit Contained in the following commands: GET OPC This read-only parameter defines the measurement unit for the M2T1 timer. Validity range: t1Unit MS100 100 msec unit Contained in the following commands: GET OPC A30808-X3247-L230-3-7619 1725 Commands Base Station Controller CML:BSC T2 T2TMUNIT T2UNIT1 T2UNIT T3UNIT1 This timer defines the waiting time for BVCI reset procedure. After a BVCI reset message sent, the PCU waits T2 seconds for acknowledge. Validity range: t2 2..119 s <DEFAULT> (default value: 10 s) Contained in the following commands: CREATE PCU, GET PCU, SET PCU, CREATE PCUTD, GET PCUTD, SET PCUTD This read-only parameter defines the measurement unit for the M3T2TM timer. Validity range: t2tmUnit SEC5 5 sec unit Contained in the following commands: GET OPC This read-only parameter defines the measurement unit for the M3T2 timer. Validity range: t2Unit1 MS100 100 msec unit Contained in the following commands: GET OPC This read-only parameter defines the measurement unit for the M2T2 timer. Validity range: t2Unit MS100 100 msec unit Contained in the following commands: GET OPC This read-only parameter defines the measurement unit for the M3T3 timer. Validity range: t3Unit1 MS100 100 msec unit Contained in the following commands: GET OPC 1726 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller T3UNIT T4 T4EUNIT T4NUNIT T4UNIT This read-only parameter defines the measurement unit for the M2T3 timer. Validity range: t3Unit MS100 100 msec unit Contained in the following commands: GET OPC Timer T4. Validity range: t4 0..9000 100 msec unit (t4 >= t1 * 2 value recommended) <DEFAULT> (default value: 200) Contained in the following commands: CREATE X25A, GET X25A, SET X25A, CREATE X25D, GET X25D, SET X25D This read-only parameter defines the measurement unit for the M2T4E timer. Validity range: t4EUnit MS100 100 msec unit Contained in the following commands: GET OPC This read-only parameter defines the measurement unit for the M2T4N timer. Validity range: t4NUnit MS100 100 msec unit Contained in the following commands: GET OPC This read-only parameter defines the measurement unit for the M3T4 timer. Validity range: t4Unit MS100 100 msec unit Contained in the following commands: GET OPC A30808-X3247-L230-3-7619 1727 Commands Base Station Controller CML:BSC T5UNIT1 T5UNIT T6UNIT T7UNIT T10UNIT T12UNIT This read-only parameter defines the measurement unit for the M3T5 timer. Validity range: t5Unit1 MS100 100 msec unit Contained in the following commands: GET OPC This read-only parameter defines the measurement unit for the M2T5 timer. Validity range: t5Unit MS100 100 msec unit Contained in the following commands: GET OPC This read-only parameter defines the measurement unit for the M2T6 timer. Validity range: t6Unit MS100 100 msec unit Contained in the following commands: GET OPC This read-only parameter defines the measurement unit for the M2T7 timer. Validity range: t7Unit MS100 100 msec unit Contained in the following commands: GET OPC This read-only parameter defines the measurement unit for the M3T10 timer. Validity range: t10Unit MS100 100 msec unit Contained in the following commands: GET OPC This read-only parameter defines the measurement unit for the M3T12 timer. Validity range: 1728 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller T13UNIT T14UNIT T17UNIT T19UNIT T20 t12Unit MS100 100 msec unit Contained in the following commands: GET OPC This read-only parameter defines the measurement unit for the M3T13 timer. Validity range: t13Unit MS100 100 msec unit Contained in the following commands: GET OPC This read-only parameter defines the measurement unit for the M3T14 timer. Validity range: t14Unit MS100 100 msec unit Contained in the following commands: GET OPC This read-only parameter defines the measurement unit for the M3T17 timer. Validity range: t17Unit MS100 100 msec unit Contained in the following commands: GET OPC This read-only parameter defines the measurement unit for the M3T19 timer. Validity range: t19Unit SEC5 5 sec unit Contained in the following commands: GET OPC Restart request time-out. Validity range: restartRequestTimeout 0..3000 (100 msec step size) <DEFAULT> (default value: 1800) Contained in the following commands: CREATE X25A, GET X25A, SET X25A, CREATE X25D, GET X25D, SET X25D A30808-X3247-L230-3-7619 1729 Commands Base Station Controller CML:BSC T21 T22 T22OR20UNIT T23 T23OR21UNIT Call request time-out. Validity range: callRequestTimeout 0..3000 (100 msec unit) <DEFAULT> (default value: 2000) Contained in the following commands: CREATE X25A, GET X25A, SET X25A, CREATE X25D, GET X25D, SET X25D Reset request time-out. Validity range: resetRequestTimeout 0..3000 (100 msec unit) <DEFAULT> (default value: 1800) Contained in the following commands: CREATE X25A, GET X25A, SET X25A, CREATE X25D, GET X25D, SET X25D This read-only parameter defines the measurement unit for the M3T22OR20 timer. Validity range: t22or20Unit SEC5 5 sec unit Contained in the following commands: GET OPC Clear request time-out. Validity range: clearRequestTimeout 0..3000 (100 msec unit) <DEFAULT> (default value: 1800) Contained in the following commands: CREATE X25A, GET X25A, SET X25A, CREATE X25D, GET X25D, SET X25D This read-only parameter defines the measurement unit for the M3T23OR21 timer. Validity range: t23or21Unit SEC5 5 sec unit Contained in the following commands: GET OPC 1730 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller T26 T28 T200 T200TD Interrupt request time-out. Validity range: interruptRequestTimeout 0..3000 (100 msec unit) <DEFAULT> (default value: 1800) Contained in the following commands: CREATE X25A, GET X25A, SET X25A, CREATE X25D, GET X25D, SET X25D Registration request time-out. Validity range: registrationRequestTimeout 0..3000 (100 msec unit) <DEFAULT> (default value: 0) Contained in the following commands: CREATE X25A, GET X25A, SET X25A, CREATE X25D, GET X25D, SET X25D This attribute contains values for the LapDm Timer 200, to be used on the different control channels. Validity range: sdcchSAPIO 0..255 (5 ms step size) (default value: 44) facchTCHF 0..255 (5 ms step size) (default value: 31) facchTCHH 0..255 (5 ms step size) (default value: 41) sacchTCHSAPIO 0..255 (10 ms step size) (default value: 90) sacchSDCCH 0..255 (10 ms step size) (default value: 90) sdcchSAPI3 0..255 (5 ms step size) (default value: 90) sacchTCHSAPI3 0..255 (10 ms step size) (default value: 135) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This attribute contains values for the LapDm Timer 200, to be used on the different control channels. Validity range: sdcchSAPIO 0..255 (5 ms step size) (default value: 44) A30808-X3247-L230-3-7619 1731 Commands Base Station Controller CML:BSC T391 T3101 T3105 facchTCHF 0..255 (5 ms step size) (default value: 31) facchTCHH 0..255 (5 ms step size) (default value: 41) sacchTCHSAPIO 0..255 (10 ms step size) (default value: 90) sacchSDCCH 0..255 (10 ms step size) (default value: 90) sdcchSAPI3 0..255 (5 ms step size) (default value: 90) sacchTCHSAPI3 0..255 (10 ms step size) (default value: 135) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This timer represents the link integrity verification repetition. Validity range: t391 1..60 <DEFAULT> (default value: 10) i The value of the timer T391 set on the BSC side must be lower than the value of the timer T392 set either on the SGSNor the network side of the Frame Relay link. Contained in the following commands: CREATE FRL, GET FRL, SET FRL This timer (btsTimer3101) is started when a channel is allocated with an IMMEDIATE ASSIGNMENT message and stopped when MS has correctly seized the channels. Validity range: tunit MS100 HLFSEC SEC5 tvalue 0..255 (default value: HLFSEC-6) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD Timer used to repeat the PHYSICAL INFORMATION message during handover procedure. T3105 * NY1 must be greater than the maximum Um Layer 2 response time. Validity range: tunit MS10 1732 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller T3107 T3109 T3111 tvalue 1..254 (default value = MS10-4) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This read-only parameter defines It consists of two fields: tunit and tvalue. Validity range: btsTimer3107 tunit MS100 HLFSEC SEC5 tvalue 0..255 Contained in the following commands: GET BTS Note Its recommended to set the related values of timers T3109 and TSYNC respecting the following rule: T3109+2sec<TSYNC If default values are set not respecting the above rule, please change the values with SET command. Timer started when a lower layer failure is detected by the network to permit a correct release of the channel in case of loss of communication. Validity range: tunit MS100 HLFSEC SEC5 tvalue 0..255 (default value = HLFSEC-24) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD Timer used to delay the channel deactivation after disconnection of the main signalling link. Its purpose is to let a sufficient time for possible repetition of the disconnection. Validity range: tunit MS100 HLFSEC SEC5 tvalue 0..255 (default value = HLFSEC-1) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD A30808-X3247-L230-3-7619 1733 Commands Base Station Controller CML:BSC T3122 T3126 T3141 T3141TD T3146TD Wait indication: this timer sets the MS (Mobile Station) waiting time before attempting another channel request after reception of the IMMEDIATE ASSIGNMENT REJECT message. Validity range: waitIndication 0..255 s (default value: 5) Contained in the following commands: GET BSC, SET BSC This parameter setting value plus one must be multiplied by 20 msec to obtain the real value used in RACH Control Parameters. Validity range: t3126 0..63 <DEFAULT> (default value: 63) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This timer is started when a tbf is assigned with an immediate assignment during a packet access procedure; it is stopped when the ms has correctly seized the tbf. Validity range: t3141 1..30 s <DEFAULT> (default value: 5) Contained in the following commands: CREATE PCU, GET PCU, SET PCU This timer is started when a tbf is assigned with an immediate assignment during a packet access procedure; it is stopped when the ms has correctly seized the tbf. Validity range: t3141TD 1..30 s <DEFAULT> (default value: 5) Contained in the following commands: CREATE PCUTD, GET PCUTD, SET PCUTD This parameter represents the maximumtime a UE has to wait to get an IMMEDIATE ASSIGNMENT (-REJECT) message from the network during a packet access procedure. Validity range: t3146TD 0..7 <DEFAULT> (default value: 6) 1734 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller T3168 T3168TD T3169 T3169TD The following list shows the correspondence between selected values and real values: 0 40 ms 1 80 ms 2 160 ms 3 320 ms 4 640 ms 5 1280 ms 6 2560 ms 7 5120 ms Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD This value plus one must be multiplied by 500 msec. to obtain the real value used in PSI messages. Validity range: t3168 0..7 <DEFAULT> (default value: 7) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This value plus one must be multiplied by 500 msec. to obtain the real value used in TD-SCDMA PSI messages. Validity range: t3168TD 0..7 <DEFAULT> (default value: 6) Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD This timer defines the waiting time for reuse TFI and USF after the thresholds N3101 and N3103 are reached. Validity range: t3169 1..30 s <DEFAULT> (default value: 5) Contained in the following commands: CREATE PCU, GET PCU, SET PCU This timer defines the waiting time for reuse TFI and USF after the thresholds N3101TD and N3103TD are reached. Validity range: t3169TD 1..30 s <DEFAULT> A30808-X3247-L230-3-7619 1735 Commands Base Station Controller CML:BSC T3172 T3172TD T3191 T3191TD (default value: 1) Contained in the following commands: CREATE PCUTD, GET PCUTD, SET PCUTD This timer is set after the reception of a PACKET ACCESS REJECT message and defines the MS waiting time before attempting another access to the cell. The timer is stopped if the MS receives a PACKET UPLINK ASSIGNMENT message. Validity range: t3172 0..255 s <DEFAULT> (default value: 5) Contained in the following commands: CREATE PCU, GET PCU, SET PCU This timer is set after the reception of a PACKET ACCESS REJECT message and defines the MS waiting time before attempting another access to the cell. The timer is stopped if the MS receives a PACKET UPLINK ASSIGNMENT message. Validity range: t3172TD 0..255 s <DEFAULT> (default value: 5) Contained in the following commands: CREATE PCUTD, GET PCUTD, SET PCUTD This timer defines the waiting time for reuse TFI and USF after having sent the last RLC block. Validity range: t3191 1..30 s <DEFAULT> (default value: 5) Contained in the following commands: CREATE PCU, GET PCU, SET PCU This timer defines the waiting time for reuse TFI and USF after having sent the last RLC block. Validity range: t3191TD 1..30 s <DEFAULT> (default value: 5) Contained in the following commands: CREATE PCUTD, GET PCUTD, SET PCUTD 1736 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller T3192 T3192TD T3193 T3193TD This parameter is used in the PSI (Packet System Information) messages. If it is set at the 3 value (corresponding to 0 ms), the timer is not started. Validity range: t3192 0..7 <DEFAULT> (default value: 0) The following list shows the correspondence between selected values and real values: 0 500 ms 1 1000 ms 2 1500 ms 3 0 ms 4 80 ms 5 120 ms 6 160 ms 7 200 ms Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter is used in the TD-SCDMA Packet SystemInformation messages. Validity range: t3192TD RELEASE WAIT_035bp WAIT_070bp WAIT_105bp WAIT_140bp WAIT_175bp WAIT_210bp WAIT_250bp <DEFAULT> (default value: WAIT_105bp) Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD This time-out timer must be set at a greater value than the timer T3192. Validity range: t3193 1..42 (100 ms unit) <DEFAULT> (default value: 4) Contained in the following commands: CREATE PCU, GET PCU, SET PCU This time-out timer must be set at a greater value than the timer T3192. Validity range: t3193TD 1..42 (100 ms unit) <DEFAULT> A30808-X3247-L230-3-7619 1737 Commands Base Station Controller CML:BSC T3195 T3195TD T3204TD T3208 (default value: 4) Contained in the following commands: CREATE PCUTD, GET PCUTD, SET PCUTD PSI Count High Rate. Validity range: t3195 0..255 s <DEFAULT> (default value: 5) Contained in the following commands: CREATE PCU, GET PCU, SET PCU PSI Count High Rate. Validity range: t3195TD 0..255 s <DEFAULT> (default value: 1) Contained in the following commands: CREATE PCUTD, GET PCUTD, SET PCUTD This timer controls the P-PDCH packet access procedure, at the UE side. Validity range: t3204TD N_0040_ms N_0080_ms N_0160_ms N_0320_ms N_0640_ms N_1280_ms N_2560_ms N_5120_ms <DEFAULT> (default value: N_1280_ms) Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD This parameter defines the waiting time for reception of the PACKET ACCESS message from the 12 UE. The network starts the timer at the starting time received in the assignment command and stops it at the reception of the PACKET ACCESS message. If T3208 expires the network releases 14 the "Packet Connection" internally. A change of the parameter becomes effective at the next packet access. Validity range: t3208 1..255 RLC/MAC blocks, where RLC (Radio Link Control) MAC (Medium Access Control) 1738 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller T3212 TAADJ TAREDLVR TARGDIR (default value: 64) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD It specifies the interval for the MS periodic location updates. The value zero indicates the MS should not performany periodic location updates. Validity range: timerPeriodicUpdateMS 0..255 in decihours (0..25.5 hours) <DEFAULT> (default value: 10) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD This attribute takes into account the propagation delay created on the BTS internal signal path in both directions. Validity range: taAdjust 0..100 (100 ns step size) <NULL> (default value: 0 if the BTS SW = BR7.0, <NULL> otherwise) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This attribute specifies the ranges for counters for TA measure. Validity range: List 7..7 of 0..255 Contained in the following commands: CREATE SCANBTSABISTD, GET SCANBTSABISTD, SET SCAN- BTSABISTD For the FILECOM software command, this parameter defines the directory name of the BSC disk of the compressed file. For the FILEDECOM software command, it defines the directory name where the decompressed files must be placed. Validity range: targetDirectory 1..45 characters string Contained in the following commands: FILECOM FILEHANDLER, FILEDECOM FILEHANDLER A30808-X3247-L230-3-7619 1739 Commands Base Station Controller CML:BSC TARGF TAVGT TAVGTTD TAVGW TAVGWTD This attribute defines the name of target compressed file. Validity range: targetFile 1..13 characters string Contained in the following commands: FILECOM FILEHANDLER This attribute indicates the signal strength filter period for power control in packet transfer mode. Validity range: tAverageTime 0..25 <DEFAULT> (default value: 5) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute indicates the signal strength filter period for power control in packet transfer mode. Validity range: tAverageTimeTD 0..25 <DEFAULT> (default value: 5) Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD This attribute indicates the signal strength filter period for power control in packet idle mode. Validity range: tAverageWeight 0..25 <DEFAULT> (default value: 15) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This attribute indicates the signal strength filter period for power control in packet idle mode. Validity range: tAverageWeight 0..25 <DEFAULT> (default value: 15) Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD 1740 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TCBCSI TCCCHLDI TCHBERR TCHBLERR This timer defines the time a BTS can remain out of service without BSC clearing of all messages concerning that particular cell. Validity range: timerForCBCServiceInterruption 0..1440 minutes Value 0 means: No message clearing from BSC' (default value: 1) Contained in the following commands: GET BSC, SET BSC This value is a threshold used by the BTS to inform the BSC about the load of CCCH. It is used in PCH and RACH load measurements. For the PCH it determines the percentage of possible paging requests stored in the BTS before CCCH load indication is sent to BSC. For the RACH the parameter determines the percentage of RACH slots related to rachLoadAveragingSlots that have to be considered busy before a CCCH load indication is sent to BSC. Validity range: thresholdCcchLoadIndication 0..100 (1% step size) (default value: 100) <DEFAULT> Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD. This attribute specifies the ranges for counters for TCH BER measure. Validity range: tchBerRange List 7..7 of 0..63 (default value: 7-15-23-31-39-47-55) Contained in the following commands: CREATE SCANAIRTSTD, GET SCANAIRTSTD, SET SCANAIRTSTD. This attribute specifies the ranges for counters for TCH BLER Measure. Validity range: tchBlerRange List 7..7 of 0..63 A30808-X3247-L230-3-7619 1741 Commands Base Station Controller CML:BSC TCONG TCONN TCONNUNIT TCONOFF (default value: 7-15-23-31-39-47-55) Contained in the following commands: CREATE SCANAIRTSTD, GET SCANAIRTSTD, SET SCANAIRTSTD. It specifies the observation windowfor the congestion detection. If the frames coming from SGSN containing congestion are equal or greater than the frame indicating no congestion, the congestion state is notified to upper layers. Validity range: timeCongestion 1..30 s <DEFAULT> (default value: 10) Contained in the following commands: CREATE FRL, GET FRL, SET FRL Wait for connection confirmation message. Validity range: tconn 0..255 units of 5 seconds for CCITT 1..72 units of 5 seconds for ANSI <DEFAULT> (default value: 3) Contained in the following commands: CREATE OPC, GET OPC, SET OPC This read-only parameter defines the measurement unit for the TCONN timer. Validity range: tConnUnit SEC5 5 sec unit Contained in the following commands: GET OPC This attribute specifies the window for congestion abatement. After a congestion notification, no other notifications are foreseen for the time configured in this parameter. This timer is needed to provide a hysteresis time in order to ensure that the traffic reduction at mobile station can be effective. Validity range: timeCongestionOff 0..30 seconds (with step 1), plus 0 value; 0 means no hysteresis time used <DEFAULT> 1742 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TDCUN TDDARFCN TDDCPAR TDDDIV TDDGQO (default value: 20) Contained in the following commands: CREATE FRL, GET FRL, SET FRL This attribute represents the number of TDCU to which the BTSMTD object must be assigned to. Validity range: tdcuNumber 0..4 Contained in the following commands: CREATE BTSMTD, GET BTSMTD This parameter defines the frequency of the TDD cell: the rule is tddArfcn = 5 * freq_uplink (or freq_downlink). Validity range: tddArfcn 9262..10113 Contained in the following commands: CREATE TGTTDD, GET TGTTDD, SET TGTTDD This parameter defines the Cell Parameter. Validity range: tddCellParameter 0..127 Contained in the following commands: CREATE TGTTDD, GET TGTTDD, SET TGTTDD This parameter indicates if diversity is used or not in TDD cell. Validity range: tddDiversity NODIVERSITY DIVERSITY Contained in the following commands: CREATE TGTTDD, GET TGTTDD, SET TGTTDD This parameter relates multiRAT mobiles; it indicates an offset which is applied for carrier level of the TDD serving cell. Validity range: tddGprsQOffset ALWAYS MDB28 MDB24 MDB20 MDB16 MDB12 MDB08 MDB04 DB00 DB04 DB08 DB12 DB16 DB20 DB24 DB28 A30808-X3247-L230-3-7619 1743 Commands Base Station Controller CML:BSC TDDMURREP TDDQO TDDSYNCCAS TDNCCPERMI <DEFAULT> (default value: DB00) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF This parameter indicates the number of TDD UTRAN cells to include in the measurement report. Validity range: tddMultiratReporting 0, 1, 2, 3 <DEFAULT> (default value: 0) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter relates multiRAT mobiles; it indicates an offset which is applied for carrier level of the TDD serving cell. Validity range: tddQOffset ALWAYS MDB28 MDB24 MDB20 MDB16 MDB12 MDB08 MDB04 DB00 DB04 DB08 DB12 DB16 DB20 DB24 DB28 <DEFAULT> (default value: DB00) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter defines the Cell Parameter. Validity range: tddSyncCase SYNC1 SYNC2 Contained in the following commands: CREATE TGTTDD, GET TGTTDD, SET TGTTDD This parameter defines the allowed Network Colour Codes (NCC) with respect to the frequency band for which measurements are allowed to be reported by the UE in the cell. Validity range: tdnccPermitted 0..15 Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD 1744 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TEI TEMPCH TEMPCHTD TEMPOFF This parameter defines the TEI (Terminal Endpoint Identifier) number. Validity range: tei 063 Contained in the following commands: CREATE BTSM, GET BTSM, CREATE BTSMTD, GET BTSMTD, GET TRX, GET TRXTD CREATE TRAU, GET TRAU This specifies the time for releasing PDCHs if no activities are done. This timer should prevent a faster PDCH channel allocation/release that can increase TDPC load. Validity range: timerEmptyChannel 1..254 s <DEFAULT> (default value: 90) Contained in the following commands: CREATE PCU, GET PCU, SET PCU This specifies the time for releasing PDCHs if no activities are done. This timer should prevent a faster PDCH channel allocation/release that can increase PPXT load. Validity range: timerEmptyChannelTD 1..254 s <DEFAULT> (default value: 90) Contained in the following commands: CREATE PCUTD, GET PCUTD, SET PCUTD This attribute applies a negative offset to C2 for the duration of penaltyTime. Validity range: temporaryOffset 0..6 (0-60 dB, unit of 10 dB), <NULL> 7 (means infinity) (default value: 1) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD. A30808-X3247-L230-3-7619 1745 Commands Base Station Controller CML:BSC TEMPPDT TEXT TF1 TGRANT TGTCELL This attribute defines the time in units of seconds for releasing a PDT with Subframe Counter > 0 if no TBF is actually using it to transfer payload. Validity range: timerEmptyPDT 1..30, <DEFAULT> (default value: 15) Contained in the following commands: CREATE PCU, GET PCU, SET PCU This attribute defines the double quoted string BMML command or failed TEST command. Validity range: text 1..256 character double quoted string Contained in the following commands: ECHO This timer defines the time for capacity reporting period used in flow control algorithm. It corresponds to the C timer reported in the GSM 08.18 recommendation. Validity range: tf1 2..9 s extremes excluded <DEFAULT> (default value: 9 s) Contained in the following commands: CREATE PCU, GET PCU, SET PCU, CREATE PCUTD, GET PCUTD, SET PCUTD This timer is used for the repetition of the VGCS_UPLINK_GRANT message during an uplink access procedure. Validity range: timerGrant 1..254 <DEFAULT> (default value: 4) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This attribute indicates the adjacent cell, namely the BTS object if it belongs to the same BSC (TGTCELL = BTSM:#/BTS:#) or the TGTBTSif it belongs to another BSC(TGTCELL = TGTBTS:#), or the TGTFDD if it is a UMTS one. Validity range: 1746 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TGUARD TGUARDTCHSD TGUARDUNIT THLEVFULHO targetCell pathname (i.e. OBJ1:2/OBJ2:1/OBJ3:5) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC, CREATE ADJC3G, GET ADJC3G, SET ADJC3G Wait to resume normal procedures for the temporary connection sections, during the restart procedure. Validity range: tGuard 0..255 units of 5 seconds <DEFAULT> (default value: 36) Contained in the following commands: CREATE OPC, GET OPC, SET OPC This timer defines the time to wait before returning TCHSD channels to TCHSDPOOL when the sub-channel to be released is coming from the SDCCHBACKUPPOOL and is the last busy sub-channel in the TCHSD. Validity range: timerGuardTchsd SEC00 SEC10 SEC11 SEC12 SEC13 SEC14 SEC15 Contained in the following commands: GET BSC, SET BSC This read-only parameter defines the measurement unit for the TGUARD timer. Validity range: tGuardUnit SEC5 5 sec unit Contained in the following commands: GET OPC This parameter defines the receive signal strength threshold for an inter-cell fast uplink HO decision. Validity range: thresholdLevFastULHo 0..63 <NULL> Contained in the following commands: GET HAND, SET HAND A30808-X3247-L230-3-7619 1747 Commands Base Station Controller CML:BSC THORQST THORQSTTD THPP THPROXT This attribute defines the minimuminterval between HO_COND_IND messages related to the same connection. Validity range: timerHoRequest 0..31 (2 SACCH multiframes step size) (default value: 5) Contained in the following commands: GET HAND, SET HAND This attribute defines the minimuminterval between HO_COND_IND messages related to the same TD-SCDMA connection. Validity range: timerHoRequestTD 0..31 (2 SACCH multiframes step size) (default value: 5) Contained in the following commands: GET HANDTD, SET HANDTD This attribute controls the post processing of the channel impulse reponse. The post processing of the channel impulse response improves the detection reliability. The attribute has two functions: - to switch the post processing on and off; - to provide a threshold in case the post processing is enabled. This threshold describes the relative power the channel impulse response has to be higher than the noise in order to be accepted. Validity range: thresPostProcessing 0.0..20.0 dB (0.5 dB step size) <DEFAULT> <NULL> (default value: 3.0 dB) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter implements 3 thresholds for TH-proximity evaluation. The first threshold range is from10 msec. to 1000 msec., the second threshold range is from 1 sec. to 100 sec., the third threshold range is from 100 sec. to 1000 sec. This parameter was introduced for an older SMG version and is no longer used starting from Release BR6.0. Validity range: thresholdProximityTimer THPROXT1 10..999 (ms) (default value: 500) THPROXT2 1..100 s (default value: 50) THPROXT3 101..1000 s 1748 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller THPROXTD THPWREV THR THSULBAL (default value: 550) Contained in the following commands: CREATE PCU, GET PCU, SET PCU This parameter implements 3 thresholds for TH-proximity evaluation. The first threshold range is from10 msec. to 1000 msec., the second threshold range is from 1 sec. to 100 sec., the third threshold range is from 100 sec. to 1000 sec Validity range: thresholdProximityTimerTD THPROXT1 10..999 (ms) (default value: 500) THPROXT2 1..100 s (default value: 50) THPROXT3 101..1000 s (default value: 550) Contained in the following commands: CREATE PCUTD, GET PCUTD, SET PCUTD This parameter defines a power threshold. If any eigenvalue is not less thresPowerEV than the biggest eigenvalue, it will be reported. Validity range: thresPowerEV 0.0..15.0 dB (0.5 dB step size) <DEFAULT> (default value: 5.0 dB) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This attribute indicates the time (in seconds) of persistency of the detected alarm before it is notified through a FER. Validity range: threshold 2..65534 <DEFAULT> (default value: 2) Contained in the following commands: CREATE ENVA, GET ENVA, SET ENVA This attribute represents the threshold to switch to UL balanced method. Validity range: thresholdSwitchULBalanced 0..2000 (unit:octects) <DEFAULT> A30808-X3247-L230-3-7619 1749 Commands Base Station Controller CML:BSC THTXBF TIAR TIARUNIT TIAS (default value: 587) Contained in the following commands: CREATE PCU, GET PCU, SET PCU, GET PCU BASICS This parameter defines the power threshold of transmit beamforming. If the ratio of signal to the biggest eigenvalue is less than thresTXBF, the transmit beamforming algorithm will ignore this signal. Validity range: thresTXBF 0.0..15.0 dB (0.5 dB step size) <DEFAULT> (default value: 5.0 dB) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD Wait for reception of a message on a connection section. Inactivity test receive timer. The SCCP connection will be released if there is no inactivity test message received within the TIAR interval. Validity range: tiar 0..255 units of 5 seconds for CCITT 132..255 units of 5 seconds for ANSI <DEFAULT> (default value: 180) Contained in the following commands: CREATE OPC, GET OPC, SET OPC This read-only parameter defines the measurement unit for the TIAR timer. Validity range: tiarUnit SEC5 5 sec unit Contained in the following commands: GET OPC Delay in sending a message on a connection section. Inactivity test sent timer. The inactivity test message is sent every TIAS interval. Validity range: tias 0..255 units of 5 seconds for CCITT 60..120 units of 5 seconds for ANSI <DEFAULT> (default value: 96) Contained in the following commands: CREATE OPC, GET OPC, SET OPC 1750 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TIASUNIT TIMADVR This read-only parameter defines the measurement unit for the TIAS timer. Validity range: tiasUnit SEC5 5 sec unit Contained in the following commands: GET OPC This parameter requires 7 input values which define the 8 ranges of Timing Advance TAred (Input_value1, Input_value2, .. , Input_value7); the input_values are related to the Timing Advance (TA) and Timing Offset (TO) of the measurement report. TA = TO_measurement_report + TA_measurement_report The TAvalue is then related to steps of 512 meters. The allowed input values for TA are 0 to 216, defined by means of rangeBound<n> fields (<n>=1..7). The correspondence between the Input_values, TA_RED and TA is the following: TA_RED_Range0: TA<= Inputvalue1 TA_RED_Range1:Input_value1 <TA<= Inputvalue2 TA_RED_Range2:Input_value2 <TA<= Inputvalue3 TA_RED_Range3:Input_value3 <TA<= Inputvalue4 TA_RED_Range4:Input_value4 <TA<= Inputvalue5 TA_RED_Range5:Input_value5 <TA<= Inputvalue6 TA_RED_Range6:Input_value6 <TA<= Inputvalue7 TA_RED_Range6:Input_value6 <TA Validity range: timingAdvanceRanges rangeBound1 0..216 (default value = 1) rangeBound2 0..216 (default value = 2) rangeBound3 0..216 (default value = 3) rangeBound4 0..216 (default value = 4) rangeBound5 0..216 (default value = 5) rangeBound6 0..216 (default value = 6) rangeBound7 0..216 (default value = 7) Contained in the following commands: CREATE SCANCTRX, GET SCANCTRX, SET SCANCTRX A30808-X3247-L230-3-7619 1751 Commands Base Station Controller CML:BSC TIMEDTBFREL TIMERFHO TIMERFHOTD TINHBAKHO This attribute is used to delay the release of a DL Temporary Block Flow (TBF). Validity range: timeDelayTBFRelease 0..49 (100 msec step size), <DEFAULT> (default value: 15) Contained in the following commands: CREATE PCU, GET PCU, SET PCU, CREATE PCUTD, GET PCUTD, SET PCUTD This attribute specifies the timer running in the BTS that controls the duration of how long a former serving cell, from which forced handover was performed to the new serving cell, may not be considered in the handover decision algorithm for power budget handovers of the new serving cell and may not be contained in the target cell list. It is started during the Directed Retry procedure at the reception of a Channel Activation message containing a Cell Identifier (no target) IE in the 'directed retry target BTS'. Validity range: timerFHO 1..320 (10 sec step size), <NULL> (default value: 12 - that is 2 minutes) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC This attribute specifies the timer running in the BTSTD that controls the duration of how long a former serving cell, from which forced handover was performed to the new serving cell, may not be considered in the handover decision algorithm for power budget handovers of the new serving cell and may not be contained in the target cell list. It is started during the Directed Retry procedure at the reception of a Channel Activation message containing a Cell Identifier (no target) IE in the 'directed retry target BTSTD'. Validity range: timerFHOTD 0..65279, <NULL> (default value: 7) Contained in the following commands: CREATE ADJCTD, GET ADJCTD, SET ADJCTD The attribute specifies the timer used by the BTS/BTSTD to penalize a cell in order to avoid back Handovers due to Power Budget. Validity range: timerInhibitBackHo 1..254 (1 second unit) <DEFAULT> 1752 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TINHFAIHO TINHRDGR TINHRUGR TINOIERCHO (default value: 30) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC, CREATE ADJCTD, GET ADJCTD, SET ADJCTD The attribute specifies the timer used by the BTS (BTSTD in case of TD-SCDMA) to exclude a cell from the target cell list, when the threshold MAXFAILHO (MAXFAILHOTD in case of TD-SCDMA) has been reached. Validity range: timerInhibitFailHo 1..254 (1 second unit) <DEFAULT> (default value: 7) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC, CREATE ADJC3G, GET ADJC3G, SET ADJC3G, CREATE ADJCTD, GET ADJCTD, SET ADJCTD The attribute specifies the minimum time between an upgrade to 14.4kbit/s and the next downgrade request. Validity range: timerInhibitRateDowngrade 2..100 (2 SACCH multiframes unit) <NULL> (default value: 52 SACCH multiframes) Contained in the following commands: GET HAND, SET HAND The attribute specifies the minimumtime between a downgrade to 9.6 kbit/s and the next upgrade request. Validity range: timerInhibitRateUpgrade 2..100 (2 SACCH multiframes unit) <NULL> (default value: 10 2SACCH multiframes) Contained in the following commands: GET HAND, SET HAND This attribute specifies the timer used by the cell to indicate how long no quality or AMR Intracell Handover has to be generated for a specific connection in the cell if the threshold MAIRACHO + 1 is reached. Validity range: timerNoIntraCellHo 1..254 (1 s step size) A30808-X3247-L230-3-7619 1753 Commands Base Station Controller CML:BSC TINT TINTUNIT TNOCH TNSVCBLK (default value: 60 s) Contained in the following commands: GET HAND, SET HAND, GET HANDTD, SET HANDTD Wait to report the abnormal release to the maintenance function. Validity range: tint 0..255 units of 5 s <DEFAULT> (default value: 36) Contained in the following commands: CREATE OPC, GET OPC, SET OPC This read-only parameter defines the measurement unit for the TINT timer. Validity range: tIntUnit SEC5 5 sec unit Contained in the following commands: GET OPC The timerNotificationChannel is used for the minimum repetition period for notification message. Validity range: timerNotificationChannel 1..254 <DEFAULT> (default value: 16) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This timer defines the waiting time for NSVC block/unblock procedure. After a NSVCblock/unblock message sent, the PCUwaits TNSVCBLK seconds for acknowledge. Validity range: timerInNsvcBlockProcedure 1..10 s <DEFAULT> (default value: 3) Contained in the following commands: CREATE PCU, GET PCU, SET PCU, CREATE PCUTD, GET PCUTD, SET PCUTD 1754 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TNSVCPTST TNSVCR TNSVCTST TO This timer defines the waiting time for NSVC test procedure. If after TNSVCPTST sec. no answers to test procedure are received, the test procedure shall be retried. Validity range: timerInNsvcPeriodicTestProcedure 1..10 s <DEFAULT> (default value: 3) Contained in the following commands: CREATE PCU, GET PCU, SET PCU, CREATE PCUTD, GET PCUTD, SET PCUTD This timer defines the waiting time for NSVC reset procedure. After a NSVC reset message sent, the PCU waits TNSVCR seconds for acknowledge. Validity range: timerInNsvcResetProcedure 1..10 s <DEFAULT> (default value: 3) Contained in the following commands: CREATE PCU, GET PCU, SET PCU, CREATE PCUTD, GET PCUTD, SET PCUTD This timer defines the periodicity of the NSVCtest procedure. The test messages are sent to SGSN when NSVC is available every TNSVCTST times. Validity range: timerInNsvcTestProcedure 1..60 s <DEFAULT> (default value: 30) Contained in the following commands: CREATE PCU, GET PCU, SET PCU, CREATE PCUTD, GET PCUTD, SET PCUTD This attribute defines the test number. This number is shown after the execution of the PERFTEST command in the field BSCETEST:<test_n>. Validity range: testObject Pathname defined by means of BSCETEST:<bscetest_n>, where <bscetest_n> is equal to 0..255. Contained in the following commands: STOPTEST BSCE A30808-X3247-L230-3-7619 1755 Commands Base Station Controller CML:BSC TOPOREL TOTERM TPMAAUUSETRES TPMANAUUUETD This is a read-only parameter which represents the topological relationship between the selected object and the other managed objects that are physically or functionally joined to it, according to the real network configuration. Validity range: topologicalRelationship sequence of addressobj Contained in the following commands: GET BTSM, GET BTSMTD, GET PCMA, GET PCMS, GET TRAU, GET SS7L, This attribute identifies the timeslot to which the cross connection ends (the information is spilled out). Validity range: It consists of two fields: pcmline and timeslot, where: PcmLine pathname: PCMA:pcma# PCMB:pcmb# PCMS:pcms# Tsl 1..31 (for PCM30) 1..24 (for PCM24) Contained in the following commands: CREATE NUC, GET NUC This attribute indicates the maximum number of AUUset with SF16 Uplink and Downlink VRU that can be allocated in the cell, in percentage respect to all AUUsets available for TDCircuit and Packet Radio Service. Validity range: TdprsMaxAUUse- tReserved 1..100 (step 1) <DEFAULT> (default value: 50) Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD This parameter indicates the maximum number of AUUset with a SF16 Uplink and Downlink VRU that can be allocated to one UE. It is composed by two fields: the first (maxAUUsetUL) indicates the maximum number of AUUset that can be allocated to one UE in Uplink direction; the second one (maxAUUsetDL) indicates the maximum number of AUUset that can be allocated to one UE in Downlink direction Validity range: tdprsMaxAUUsetUETD <DEFAULT> 1756 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TPMANUEALTD TPMASTATIME TPPATHTD maxAUUsetUL 1..42 (default value: 16) maxAUUsetDL 1..42 (default value: 16) Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD This parameter defines the maximum number of UEs that can be multiplexed within one secondary Downlink PDPCH. Validity range: tdprsSMAXUEALLOCAT- EDTD 1..15 <DEFAULT> (default value: 15) Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD This attribute indicates the number of RLC/MAC radio blocks after which the change timeslot allocation has to be performed, otherwise the UE connection is interrupted. Validity range: TdprsMaxStar- tingTime 5..255 (step 1) <DEFAULT> (default value: 100) Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD This parameter indicates whether or not a mobile station of a certain priority class is authorised to do a randomaccess for request of a TD- SCDMA packet switched service. The field is coded according to the following table: PKANA packet access is not allowed in the cell; PKAAP1 packet access is allowed for priority class 1; PKAAP2 packet access is allowed for priority class 1 to 2; PKAAP3 packet access is allowed for priority class 1 to 3; PKAAP4 packet access is allowed for priority class 1 to 4; Validity range: tdprsPriorityAccessThresholdTD PKANA PKAAP1 PKAAP2 PKAAP3 PKAAP4 <DEFAULT> (default value: PKAAP4) Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD A30808-X3247-L230-3-7619 1757 Commands Base Station Controller CML:BSC TPUECHTS TRACE TRACEMG TRACEMR TRACERECTYP This attribute indicates the number of RLC/MAC radio blocks after which the change timeslot allocation has to be performed, otherwise the UE connection is interrupted. Validity range: TdprsMaxStar- tingTime WEIGHT_00, WEIGHT_50 <DEFAULT> (default value: WEIGHT_50) Contained in the following commands: CREATE PTPPKFTD, GET PTPPKFTD, SET PTPPKFTD Debugging coded string. Validity range: debuggingCodedString alphanumeric string (10 characters) (default value: NULL string) Contained in the following commands: CREATE X25A, GET X25A, SET X25A, CREATE X25D, GET X25D, SET X25D This parameter allows to modify the granularity of time for trace measurement reports. Validity range: traceMeasureGranularity 1..254 (default value: 1) Contained in the following commands: GET BSC, SET BSC This parameter allows to enable or disable the trace measurement reports. Validity range: traceMeasureReport TRUE FALSE (default value: TRUE) Contained in the following commands: GET BSC, SET BSC This attribute specifies the kind of data to be collected. Validity range: traceRecordType Message All Contained in the following commands: CREATE CTRSCHED, GET CTRSCHED, SET CTRSCHED 1758 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TRACEREF TREL TRELUNIT TRESEL This parameter defines the trace reference. Validity range: traceReference 0..65535 (default value: NULL string) Contained in the following commands: UPLIMSITR TRACE Wait for release complete message. Validity range: trel 0..255 units of half a second for CCITT 20..40 units of half a second for ANSI (default value: 20 for CCITT and 30 for ANSI) Contained in the following commands: CREATE OPC, GET OPC, SET OPC This read-only parameter defines the measurement unit for the TREL timer. Validity range: trelUnit HLFSEC half a second unit Contained in the following commands: GET OPC If the MS has performed an abnormal release with cell reselection from this cell, the MS is not allowed to reselect this cell for TRESEL seconds if another cell is available. The following list shows the correspondence between selected values and real values: 0 5 s 1 10 s 2 15 s 3 20 s 4 30 s 5 60 s 6 120 s 7 300 s Validity range: timerReselection 0..7 <DEFAULT> (default value: 0 [5 s]) Contained in the following commands: CREATE PTPPKF, GET PTPPKF, SET PTPPKF A30808-X3247-L230-3-7619 1759 Commands Base Station Controller CML:BSC TRFCT TRFHITH TRFHOE TRFHOM TRFHORXLVMOFF This parameter establishes for each BTS the period of time to wait before evaluating the traffic level. Validity range: trafficControlTimer 10..200 half-seconds <DEFAULT> (default value: 20 [10 s]) Contained in the following commands: GET BSC, SET BSC This parameter defines the high traffic level threshold in order to establish if the handover for traffic reason has to be enabled/disabled. The value of the parameter is given in percentage form. Validity range: trafficHighThreshold 50..100 <NULL> (default value: 90) Contained in the following commands: GET HAND, SET HAND This parameter allows to enable/disable the handover for traffic reason feature in the BTS. Validity range: trafficHandoverEnable TRUE FALSE <NULL> (default value: FALSE) Contained in the following commands: GET HAND, SET HAND This parameter defines the nominal cell border between cells. The set value ranges from -63 dB to +63 dB (1 dB step size). Validity range: trafficHandoverMargin 0..126 <NULL> (default value: 67 [+4 dB]) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC This attribute defines a neighbour cell specific level offset that is added to RXLREVMIN value of a particular neighbour cell, during the target cell list generation for traffic handover. Iis foreseen in order to make sure that a traffic handover is only attempted towards those target cells that provide sufficient service quality conditions It enhances the minimumcriteria defined by the attribute RXLEVMIN. Validity range: trafficHoRxLevMinOffset -24...+24 dB (1 dB step size) 1760 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TRFHOT TRFKPRI TRFLTH TRFMMA <DEFAULT> <NULL> (default value: 6 dB) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC This parameter represents the timer which is used to establish the period of time to wait before updating the m value. The m value is increased if the handover for traffic reason is enabled and decreased if the handover for traffic reason is disabled, m is updated until it reaches value 0. Validity range: trafficHandoverTimer 2..20 s <NULL> (default value: 10) Contained in the following commands: GET HAND, SET HAND This parameter determines whether candidate cells have to be of the same priority as the serving cell or may be of the same or higher priority. Validity range: trafficKeepPriority TRUE FALSE <NULL> (default value: FALSE) Contained in the following commands: GET HAND, SET HAND This parameter defines the low traffic level threshold in order to establish if a cell can be a candidate to receive handover for traffic reason. The value of the parameter is given in percentage form. Validity range: trafficLowThreshold 0..85 <NULL> (default value: 70) Contained in the following commands: GET HAND, SET HAND This parameter establishes the maximum reduction for TRFHOM. Validity range: trafficMarginMaximum 1..48 dB <NULL> (default value: 9) Contained in the following commands: GET HAND, SET HAND A30808-X3247-L230-3-7619 1761 Commands Base Station Controller CML:BSC TRFMS TRFPS TRFPSCTRLT TRXAREA TRXFREQ This parameter establishes the minimum reduction for TRFHOM. Validity range: trafficMarginStep 1..6 dB <NULL> (default value: 3) Contained in the following commands: GET HAND, SET HAND This parameter defines the flag enbling the traffic control algorithm Validity range: trafficPs FALSE, TRUE <DEFAULT> (default value: FALSE) Contained in the following commands: SET BSC, GET BSC This field indicates the time period for the estimate of gprs cell occupa- tion. NOTE: in the current release this attribute is NOT significant. Validity range: trafficPsControlTimer 1,2,....,100 <DEFAULT> (default value: 5) Contained in the following commands: CREATE PTPPKF, SET PTPPKF, GET PTPPKF The attribute specifies whether a TRX belongs to a concentric cell and to which area it belongs. Validity range: trxArea NONE INNER COMPLETE <DEFAULT> (default value: NONE) Contained in the following commands: CREATE TRX, GET TRX, SET TRX This attribute is used to assign a constant radio frequency to a transceiver. The significance of this attribute is implementation dependent. Validity range: carrierFrequency BCCHFREQ CALLF<nn> where <nn> = 01 to 63 The frequencies set to "cellAllocation" attribute must follow these rules: 1762 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TRXFREQV TRXFREQVTD TRXMD if SYSID = BB900 then 1 =< frequency =< 124 if SYSID = F2ONLY900 then 0 =< frequency =< 124 975 =< frequency =< 1023 if SYSID = EXT900 then 0 =< frequency =< 124 975 =< frequency =< 1023 if SYSID = DCS1800 then 512 =< frequency =< 885 if SYSID = GSMR then 955 =< frequency =< 974 if SYSID = PCS1900 then 512 =< frequency =< 810 The difference between the frequency bands of F2ONLY900 and EXT900 is that in the second case the extended band (frequencies 0, 975...1023) can be used only for the traffic purposes and for phase 2 mobile, no interaction between the two bands (base and extended) is foreseen and the base band can be used also by phase 1 mobile. In case of F2ONLY900 the phase 1 mobiles cannot support this config- uration that is reserved for phase 2 mobiles. Contained in the following commands: CREATE TRX, GET TRX, SET TRX This read-only parameter defines the value of TRX frequency. Validity range: carrierFrequencyValue 0..1023 Contained in the following commands: GET TRX This read-only parameter defines the value of TRXTD frequency. Validity range: freqBandNum 5..5 radioFreqNum 0..67 Contained in the following commands: GET TRXTD This parameter states if TRX should be associated to a board with EDGE capabilities. Validity range: trxMode GSM EDGE <DEFAULT> (default value: GSM) Contained in the following commands: CREATE TRX, GET TRX, SET TRX A30808-X3247-L230-3-7619 1763 Commands Base Station Controller CML:BSC TRXTDFREQ TSBS TSBSUNIT TSC TSLA This parameter defines the transmit and receive frequency of TD- SCDMA transceiver (TRXTD). Validity range: trxtdFrequency BCCHFREQTD CALLF01TD CALLF02TD Contained in the following commands: CREATE TRXTD, GET TRXTD, SET TRXTD State information. Validity range: tsbs 0..255 units of half a second <DEFAULT> (default value: 60) Contained in the following commands: CREATE OPC, GET OPC, SET OPC This read-only parameter defines the measurement unit for the TSBS timer. Validity range: tsbsUnit HLFSEC half a second unit Contained in the following commands: GET OPC Specifies the Training Sequence Code of a radio channel. If TSC is not set the training sequence code is taken fromthe BCC of the BSIC attribute in the BTS command. Validity range: trainingSequenceCode 0..7 <DEFAULT> <NULL> (default value: this value indicates that the attribute is equal to BCC value of BSIC attribute in BTS object) Contained in the following commands: CREATE CHAN, GET CHAN, SET CHAN Identifies the pcma number and the timeslot number for allocation of ss7 link. Validity range: pcmaNumber 0..143 tslNumber 1..31 for PCM30 line 1764 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TSPRILVBOUN TSULBAL TSYNC 1..24 for PCM24 line Contained in the following commands: CREATE SS7L, GET SS7L This parameter pecifies boundary limits of five priority bands for UL and DL timeslots. The BSC shall map the received priorities values into these five bands. Validity range: tSPriorityLevelBoundaries priorityBounderie1 0..100 (default value: 80) priorityBounderie2 0..100 (default value: 60) priorityBounderie3 0..100 (default value: 40) priorityBounderie4 0..100 (default value: 20) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This attribute represents the timer to switch to UL balanced method. Validity range: timeSwitchULBalanced 0..100 (unit: 100 ms) <DEFAULT> (default value: 20) Contained in the following commands: CREATE PCU, GET PCU, SET PCU, GET PCU BASICS Note Its recommended to set the related values of timers T3109 and TSYNC respecting the following rule: T3109+2sec<TSYNC If default values are set not respecting the above rule, please change the values with SET command. This attribute defines the timer value which is used by the BTS to supervise time-out of TRAU frame handling. This timer is used only if a BTS-TRAU traffic connection is already established. It is started after 3 TRAU-frames have not been correctly received and is cleared if a frame is received again. If it expires at BTS side, a connection failure indication is reported to the BSC; if it expires at TRAU side a warning is generated. Validity range: tSync 10..10000 (10 ms step size) (default value: 1000) A30808-X3247-L230-3-7619 1765 Commands Base Station Controller CML:BSC TSYNCDL TSYNCR TSYNCUL (recommended value 200) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE TRAU, GET TRAU, SET TRAU, CREATE BTSTD, GET BTSTD, SET BTSTD If tSyncDL expires a Connection Failure with cause Remote Transcoder Failure is sent to the BSC. Validity range: tSynchronizationDownlink 10..10000 (10 ms unit) <NULL> (default value: 1000) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD The timer starts if the control bit uplink frame error (UFE) indicates an error and no error on the synchronization pattern is detected. If tSyncR expires the BTS starts sending data frames. Validity range: tSynchronizationR 10..10000 (10 ms unit) <NULL> (default value: 400) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD The timer starts if the control bit uplink frame error (UFE) indicates an error and no error on the synchronization pattern is detected. If tSyncUL expires a Connection Failure with cause Remote Transcoder Failure is sent to the BSC. Validity range: tSynchronizationUplink 10..10000 (10 ms unit) <NULL> (default value: 1000) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD 1766 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TTRAU TUPLREP TWCUNIT TWCUSER TXDIVTSEXCPT This attribute defines the timer value which is used by the BTS to supervise time-out of TRAU datalink (traffic) at connection establishment or handover. It is set when sending the first TRAUdata frame uplink and cleared when the first frame downlink arrives. If it expires, a connection failure indication is reported to the BSC. Validity range: tTrau 10..10000 10 milliseconds step size (default value: 1000) (recommended value 150) Contained in the following commands: CREATE BTS, GET BTS, SET BTS, CREATE BTSTD, GET BTSTD, SET BTSTD This timer is used by BTS for starting the uplink reply procedure. Validity range: timerUplinkReply 5..60 s <NULL> (default value: 20 s) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This read-only parameter defines the measurement unit for the TWCUSER timer. Validity range: twcUnit HLFSEC half a second unit Contained in the following commands: GET OPC Manufacturer dependent timer. Validity range: twcUser 0..255 units of half a second (default value: 20) Contained in the following commands: CREATE OPC, GET OPC, SET OPC This parameter allows to configure time slots or logical channels which are excluded from being sent in TX diversity Time Shift mode. Validity range: txDivTimeShiftExcept NONE SCH BCCHTRXTS0 BCCHTRX <DEFAULT> A30808-X3247-L230-3-7619 1767 Commands Base Station Controller CML:BSC TXDIVTSPAR TXINT (default value: NONE) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter defines the time shift of the TX signals of master and slave CU. The attribute is meaningless if ETXDIVTS parameter is set at FALSE. Validity range: txDivTimeShiftParam MDB5 MDB475 MDB45 MDB425 MDB4 MDB375 MDB35 MDB325 MDB3 MDB275 MDB25 MDB225 MDB2 MDB175 MDB15 MDB125 MDB1 MDB075 MDB05 MDB025 DB0 DB025 DB05 DB075 DB1 DB125 DB15 DB175 DB2 DB225 DB25 DB275 DB3 DB325 DB35 DB375 DB4 DB425 DB45 DB475 DB5 <DEFAULT> (default value: MDB1) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This parameter defines the number of frames before sending the first SYNC1 burst during the access procedure. Validity range: txInteger 0..15 <DEFAULT> (default value: 4) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD 1768 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller TXPMAREDTD TXPPCCPCH TXPWRDLPTS TYPPROC UADJ This parameter is used for determination of minimal transmit power of base station and UE. Validity range: txPwrMaxReductionTD 0..30 (1 dB step) <DEFAULT> (default value: 30) Contained in the following commands: CREATE TRXTD, GET TRXTD, SET TRXTD This parameter defines the relative power transmitted level on the PCCPCH channel referred to the value indicate in TXPWRDLPTS parameter. Validity range: txPwrOfPCCPCH -1.0..28.5 (step 0.5) (default value: 23 dB) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD. This parameter defines the transmit power on DwPTS(downlink pilot timeslot). Validity range: txPwrOfDwPTS 30..89 dBm (step 1 dBm) <DEFAULT> (default value: 76 dBm) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This attribute identifies the processor. Validity range: typeProcessor MPCC_ACT,MPCC_SBY,TDPC_ACT,TDPC_SB Y (default value: MPCC_ACT) Contained in the following commands: MEMDUMP BSC This attribute is used in Better Cell Handover fromGSMto UMTS to adjust the carrier level of the related UMTS adjacent cell compared to the carrier level of the serving cell. The parameter is coded according to the following table: 0 - 63 dB 1 - 62 dB
62 - 1 dB A30808-X3247-L230-3-7619 1769 Commands Base Station Controller CML:BSC UERSCPR UETSCPMA UETSCPMAC UETSISCPR 63 0 dB 64 + 1 dB ... ... 125 + 62 dB 126 + 63 dB Validity range: umtsAdjust 0..126 <DEFAULT> (default value: 63) Contained in the following commands: CREATE ADJC3G, GET ADJC3G, SET ADJC3G This attribute specifies the ranges for counters for UE RSCP Measure. Validity range: ueRscpRange List 7..7 of 0..91 (default value: 12-23-34-45-56-67-78) Contained in the following commands: CREATE SCANAIRTSTD, GET SCANAIRTSTD, SET SCANAIRTSTD. This parameter defines maximumTSCP the UE (User Equipment) is allowed to use in the cell. Validity range: ueTSCPMax -49..34 dBm (1 dBm step size) (default value: -17 dBm) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter defines the maximum TSCP that a UE (User Equipment) is allowed to use in the adjacent cell. Validity range: ueTSCPMaxCell -49..34 dbm (default value: -17dBm) Contained in the following commands: CREATE TGTBTSTD, GET TGTBTSTD, SET TGTBTSTD This attribute specifies the ranges for counters for UE TS RSCP Measure. Validity range: tueTsIscpRange List 7..7 of 0..91 1770 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller UETXPMACC UETXPR ULAB (default value: 12-23-34-45-56-67-78) Contained in the following commands: CREATE SCANAIRTSTD, GET SCANAIRTSTD, SET SCANAIRTSTD. This parameter defines the maximum TX power an UE (User Equipment) may use when transmitting on a Common Channel, also including the SYNC1 burst transmission on the UpPTS. The parameter values are coded according to the following table: 00 -50 dBm =< UE Transmitted Power < -49 dBm 01 -49 dBm =< UE Transmitted Power < -48 dBm 02 -48 dBm =< UE Transmitted Power < -47 dBm ... ... 81 31 dBm =< UE Transmitted Power < 32 dBm 82 32 dBm =< UE Transmitted Power < 33 dBm 83 33 dBm =< UE Transmitted Power Validity range: uETxPwrMaxCcch 0..83 <DEFAULT> (default value: 83) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This attribute specifies the ranges for counters for UE TX POWER Measure. Validity range: ueTxPowerRange List 7..7 of 21..104 (default value: 31-42-53-64-75-86-97) Contained in the following commands: CREATE SCANAIRTSTD, GET SCANAIRTSTD, SET SCANAIRTSTD. This parameter assigns a user friendly name (is a user-defined string) to the BSC Executable Software Unit DB (note it is the same of the related BSC Reusable Software Unit DB). Validity range: userLabel 1..30 characters string Contained in the following commands: GETBSCESUDB, GETNEYESUSW, NEDOWNLOADNEYESUSW, CREATERSUDB, GET RSUDB, SET RSUDB, CREATERSUSWLH, GET BSCESUSW, GET RSUSWLH, SET RSUSWLH, CREATE RSUPCH, GET RSUPCH A30808-X3247-L230-3-7619 1771 Commands Base Station Controller CML:BSC ULABSWLH ULDCAST ULSIRACST ULSRP This parameter defines the user label of the software load header and it consists of 30 characters string. Validity range: userLabelSwLoadHeader 1..30 characters string Contained in the following commands: CREATE RSUEXE, CREATE RSUPCH This parameter defines if the Priority based Admission Control information for all UL timeslots is sent by the BTSC within the message RF_TS_PRIORITY_UPDATE_IND to the BSC. Validity range: uplinkDCAStatus TRUE FALSE <DEFAULT> (default value: TRUE) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter defines if the SIR based Admission Control information for all UL timeslots is sent to the BSC. In case of an Immediate Assignment Procedure the information is included in the Channel Required message; in case of an Assignment Procedure the information is included in the Physical Context Confirm message and in case of an Intracell Handover the information is included in the Intracell Handover Condition Indication message. Validity range: uplinkSIRACStatus TRUE FALSE <DEFAULT> (default value: TRUE) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This parameter defines the repetition times of SS(Synchronisation Shift) command. Validity range: uLSCRep 0..7 <DEFAULT> (default value: 0) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD 1772 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller ULSS UMECNO UMTSSRHPRI UPGRFREQ This parameter defines the step size of adjustment when doing uplink synchronisation control. Validity range: uLSCStep N_<nn>_8 <nn>=1 to 8 <DEFAULT> (default value: N_01_8) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This attribute defines the minimum level which is required to include an UMTS FDD cell into the handover target cell list in case of an Imperative HO; it is valid only for FDD cells in case FDDREPQTY = EC_N0. The parameter is coded according to the following table: 0 CPICH Ec/No < - 24 dB 1 - 24 dB <= CPICH Ec/No < - 23.5 dB
48 - 0.5 dB <= CPICH Ec/No < 0 dB 49 0 dB <= CPICH Ec/No Validity range: umtsMinEcNo 0..49 <DEFAULT> (default value: 19) Contained in the following commands: CREATE ADJC3G, GET ADJC3G, SET ADJC3G This parameter indicates if mobile can search 3G cells when BSIC decoding is required, i.e. if the searching time can be longer than normal value (13 s instead of 10 s). Validity range: umtsSearchPriority FALSE TRUE <DEFAULT> (default value: TRUE) Contained in the following commands: CREATE BTS, GET BTS, SET BTS This attribute defines the periodicity of radio resources upgrade attempts on packet services. Validity range: UpgradeFrequency <DEFAULT> Uplink SEC1 SEC2 SEC3 SEC4 SEC5 SEC6 A30808-X3247-L230-3-7619 1773 Commands Base Station Controller CML:BSC UPPTSRXPL UPTLEVD UPTLEVU UPTQUAD SEC7 SEC8 (default value: SEC1) Downlink SEC1 SEC2 SEC3 SEC4 SEC5 SEC6 SEC7 SEC8 (default value: SEC1) Contained in the following commands: GET BSC, SET BSC This parameter defines the expected receive power level on the UpPTSphysical channel. This value is used by the UEto compute the transmit power level when sending the first SYNC1 burst. Validity range: upPTSRXPL -120.5..-57.0 dBm (0.5 dBm step size) <DEFAULT> (default value: -110 dBm) Contained in the following commands: CREATE BTSTD, GET BTSTD, SET BTSTD This attribute defines the upper threshold of the received signal level on downlink for power reduction. Validity range: pcUpperThresholdLevDL 0..63 dBr (default value: 35) For the values make references to Appendix B: Group 2. Contained in the following commands: GET PWRC, SET PWRC This attribute defines the upper threshold of the received signal level on uplink for power reduction. Validity range: pcUpperThresholdLevUL 0..63 dBr (default value: 35) For the values make references to Appendix B: Group 2. Contained in the following commands: GET PWRC, SET PWRC This attribute defines the upper threshold of the received signal quality on downlink for power reduction. Validity range: pcUpperThresholdQualDL 0..7 (default value: 2) 1774 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller UPTQUAMRDL UPTQUAMRUL UPTQUAU For the values make references to Appendix B: Group 3. Contained in the following commands: GET PWRC, SET PWRC This parameter determines the upper power control downlink quality threshold for AMR calls. In case of an AMR call UPTQUAMRDL eclipses the threshold UPTQUAD, i.e. for AMRcalls the power control algorithmdecreases the DL transmit power if the quality exceeds the threshold determined by UPTQUAMRDL. As UPTQUAMRDL is entered in C/I values, but the MS reports the serving cell quality in form of RXQUAL values, the BTS performs an internal mapping of RXQUAL to C/I values prior to the power control decision. Validity range: pcUpperThresQualAMRDL 0..30 (1 dB step size) <NULL> (default value: 13) Contained in the following commands: GET PWRC, SET PWRC This parameter determines the upper power control uplink quality threshold for AMR calls. In case of an AMR call UPTQUAMRUL eclipses the threshold UPTQUAU, i.e. for AMRcalls the power control algorithmdecreases the UL transmit power if the quality exceeds the threshold determined by UPTQUAMRUL. As UPTQUAMRUL is entered in C/I values, but the BTS measures the serving cell quality in formof RXQUAL values, the BTS performs an internal mapping of RXQUAL to C/I values prior to the power control decision. Validity range: pcUpperThresQualAMRUL 0..30 (1 dB step size) <NULL> (default value: 13) Contained in the following commands: GET PWRC, SET PWRC This attribute defines the upper threshold of the received signal quality on uplink for power reduction. Validity range: pcUpperThresholdQualUL 0..7 (default value: 2) For the values make references to Appendix B: Group 3. Contained in the following commands: GET PWRC, SET PWRC A30808-X3247-L230-3-7619 1775 Commands Base Station Controller CML:BSC USECNO USG USRSCP This attribute defines the threshold above which BTS initiates a Sufficient UMTS Coverage HO fromGSMto UMTS in case of FDD when FDDREPQTY attribute is set at EC_N0 value. The parameter is coded according to the following table: 0 CPICH Ec/No < - 24 dB 1 - 24 dB <= CPICH Ec/No < - 23.5 dB
48 - 0.5 dB <= CPICH Ec/No < 0 dB 49 0 dB <= CPICH Ec/No Validity range: umtsSuffEcNo 0..49 <DEFAULT> (default value: 23) Contained in the following commands: CREATE ADJC3G, GET ADJC3G, SET ADJC3G This attribute indicates whether the adjacent cell must be sent over system information 2, 5 or both. Validity range: usage SI_2 SI_5 SI_2_5 <DEFAULT> (default value: SI_2_5) Contained in the following commands: CREATE ADJC, GET ADJC, SET ADJC This attribute defines the threshold above which BTS initiates a Sufficient UMTS Coverage HO fromGSMto UMTS in case of TDD adjacent cell or in case of FDD when FDDREPQTY attribute is set at RSCP value. The variable default must be managed depending on whether the adjacent cell is a TDD or a FDD one. The parameter is coded according to the following table: 0 RSCP < - 115 dBm 1 - 115 dBm <= RSCP < - 114 dBm
62 - 54 dBm <= RSCP < - 53 dBm 63 - 53 dBm <= RSCP Validity range: umtsSuffRscp 0..63 <NULL> (default value: 8 for FDD, 24 for TDD) Contained in the following commands: CREATE ADJC3G, GET ADJC3G, SET ADJC3G 1776 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller UTRANRSCPR UTRANTSISCPR UTRANTXCPR UTRANTXPR This attribute specifies the ranges for counters for UTRAN RSCP Measure. Validity range: utranRscpRange List 7..7 of 0..81 (default value: 10-20-30-40-50-60-70) Contained in the following commands: CREATE SCANAIRTSTD, GET SCANAIRTSTD, SET SCANAIRTSTD. This attribute specifies the ranges for counters for UTRAN TS ISCP Measure. Validity range: utranTsIscpRange List 7..7 of 0..81 (default value: 10-20-30-40-50-60-70) Contained in the following commands: CREATE SCANAIRTSTD, GET SCANAIRTSTD, SET SCANAIRTSTD. This attribute specifies the ranges for counters for UTRAN TX CODE POWER Measure. Validity range: utranTxCodePowerRange List 7..7 of 10..122 (default value: 24-39-54-69-84-99-104) Contained in the following commands: CREATE SCANAIRTSTD, GET SCANAIRTSTD, SET SCANAIRTSTD. This attribute specifies the ranges for counters for UTRAN TX Measure. Validity range: utranTxPowerRange List 7..7 of 16..116 (default value: 24-39-54-69-84-99-104) Contained in the following commands: CREATE SCANAIRTSTD, GET SCANAIRTSTD, SET SCANAIRTSTD. A30808-X3247-L230-3-7619 1777 Commands Base Station Controller CML:BSC VER VGRULF VOLDL VOLUL This read-only parameter defines the version of the managed element. Validity range: version 1..26 characters string Contained in the following commands: GET BSCESUSW, GET MEL, GET NEYESUSW, GET RSUSWLH, GET RSUEXE The voice GroupUplinkFree is used for the repetition of the UPLINK_FREE message. Validity range: voiceGroupUplinkFree 1..254 <DEFAULT> (default value: 2) Contained in the following commands: CREATE BTS, GET BTS, SET BTS Indicates a value for the time slot volume attenuation in downlink direction (MSC ---> MS). Validity range: volumeDownlink 0..24 (1 dB step size) where: 0 = -12 dB 24 = 12 dB (default value: 12 = 0 dB) Contained in the following commands: GET TSLA, SET TSLA Indicates a value for the time slot volume attenuation in uplink direc- tion (MS --> MSC). Validity range: volumeUplink 0..24 (1 dB step size) where: 0 = -12 dB 24 = 12 dB (default value: 12 = 0 dB) Contained in the following commands: GET TSLA, SET TSLA 1778 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller WMOD WRTYP X121ADDR This attribute indicates whether the created PCMS or PCMB will be required to work in Single Trunk Mode or in Double Trunk Mode. Validity range: workingMode SINGLE_TRUNK DOUBLE_TRUNK <DEFAULT> (default value: DOUBLE_TRUNK) Contained in the following commands: CREATE PCMB, GET PCMB, CREATE PCMS, GET PCMS This parameter forces the type of asynchronous mode of PLLH. Validity range: wordType Tune DAC Contained in the following commands: FORCSYNC NTW This attribute indicates the X25 network address. Validity range: x121Addr <NULL> string 1..33 chars Contained in the following commands: CREATE CBCL, GET CBCL, CREATE OMAL, GET OMAL, SET OMAL A30808-X3247-L230-3-7619 1779 Commands Base Station Controller CML:BSC 5 Appendix A: ME-Address Value List This appendix contains the list of the ME (Maintenance Entity) address accepted values for the relevant managed objects. ME-Address Accepted Values <adjcn> 0..31 <adjc3gn> 0..63 <adjctdn> 0..31 <airtstdn> 0..6 <bscen> 0..0 <bscn> 0..0 <bscesudbn> 0..19 <bscesuswn> 0..19 <bscetestn> 0..255 <bscosudbn> 0..0 <bscosuswn> 0..0 <btsen> 0..199 <btsmn> 0..199 <btsmosuswn> 0..0 <btsmtdn 0...363 <btsmtdosuswn> 0..0 <btsn> 0..23 <btstdn> 0..2 <cbcln> 0..1 <cpexn> 0..1 <ctrcon> 0..0 <ctrschedn> 0..31 <dk40n> 0..0 <diskn> 0..1 <envan> 0..20 <epwrn> 0..1 <fann> 0..0 <fhsyn> 1..10 <filehandlern> 0..0 <frln> 0..755 <handn> 0..0 <handtdn> 0..0 <instn> 0..89 <ipli> 0..0 <ixltn> 0..1 <licdn> 0..9 <licdsn> 0..1 <lpdlmn> 0..7 <lpdlmntd> 0..7 <lpdlrn> 0..0 1780 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller <lpdlrtdn> 0..0 <lpdlsn> 0..0 <meln> 0..0 <memtn> 0..1 <mpccn> 0..1 <neyesuswn> 0..39 <nsvcn> 0..755 <ntwn> 0..1 <nucn> 0..29 <omaln> 0..1 <opcn> 0..0 <pcman> 0..191 <pcmbn> 0..117 <pcmgn> 0..31 <pcmsn> 0..47 <pcun> 0..11 <pcutdn> 0..11 <ppccn> 0..1 <ppcun> 0..3 <ppldn> 0..14 <ppxln> 0..1 <ppxpn> 0..11 <ppxtn> 0..11 <ppxun> 0..11 <ptppkfn> 0..0 <ptppkftdn> 0..0 <pwrcn> 0..0 <pwrctdn> 0..0 <pwrdn> 0..1 <reminvn> 0..0 <rfloopn> 0..0 <rsudbn> 0..19 <rsuexen> 0..249 <rsupchn> 0..399 <rsuswlhn> 0..59 <rtsln> 0..7 <scann> 0..89 <scann> 0..4 (SCANGPRS case) <scan> 0..0 <scancon> 0..0 <scantdn> 0..89 <scantdn> 0..4 (SCANGPRSTD case) <ss7ln> 0..15 <ss7sn> 0..1 <subtslbn> 0..3 <swibeamn> 0..0 <syncn> 0..35 A30808-X3247-L230-3-7619 1781 Commands Base Station Controller CML:BSC <syncon> 0..0 <synen> 0..1 <sysinitn> 0..0 <tdcun> 0..4 <tdpcn> 0..1 <tgtbtsn> 0..1499 <tgtbtstdn> 0..499 <tgtfddn> 0..1499 <tgttddn> 0..1499 <tgtptppkfn> 0..0 <tracen> 0..0 <trauen> 0..35 <traun> 0..47 <trauosuswn> 0..0 <trxn> 0..23 <trxtdn> 0..2 <tslbn> 1..31 <tsln> 1..31 <x25an> 0..1 <x25dn> 0..1 1782 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller A30808-X3247-L230-3-7619 1783 Commands Base Station Controller CML:BSC 6 Appendix B: Special Parameter Values This appendix contains complete tables with all values for the particular groups of parameters which are listed below. Group 1 BCCHFREQ bcchFrequency Group 2 HOLTHLVDL hoLowerThresholdLevDL HOLTHLVUL hoLowerThresholdLevUL HOTDLINT hoThresholdLevDLintra HOTULINT hoThresholdLevULintra LOWTLEVD pcLowerThresholdLevDL LOWTLEVU pcLowerThresholdLevUL UPTLEVD pcUpperThresholdLevDL UPTLEVU pcUpperThresholdLevUL RXLEVMIN rxLevMinCell RXLEVMINTD rxLevMinCellTD Group 3 HOLTHQUDL hoLowerThresholdQualDL HOLTHQUUL hoLowerThresholdQualUL LOWTQUAD pcLowerThresholdQualDL LOWTQUAU pcLowerThresholdQualUL UPTQUAD pcUpperThresholdQualDL UPTQUAU pcUpperThresholdQualUL RUGRDL rateUpgradeDownlink RUGRUL rateUpgradeUplink RDGRDL rateDowngradeDownlink RDGRUL rateDowngradeUplink RHOLTQDL rateHoLowerThresholdQualDownlink RHOLTQUL rateHoLowerThresholdQualUplink Group 4 MSTXPMAXGSM mSTxPwrMaxGsm MSTXPMAXDCS mSTxPwrMaxDcs MSTXPMAXPCS mSTxPwrMaxPcs MSTXPMAXUMTS msTxPwrMaxUmts Group 5 EPOOL enablePooling DEFPOOLTYP defPoolType POOLTYP poolType Group 6 HOLTHQAMRDL hoLowerThresQualAMRDL HOLTHQAMRUL hoLowerThresQualAMRUL HOTHAMRCDL hoThresAMRComprDL 1784 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller HOTHAMRCUL hoThresAMRComprUL HOTHAMRDDL hoThresAMRDecomprDL HOTHAMRDUL hoThresAMRDecomprUL LOWTQUAMRDL pcLowerThresQualAMRDL LOWTQUAMRUL pcLowerThresQualAMRUL UPTQUAMRDL pcUpperThresQualAMRDL UPTQUAMRUL pcUpperThresQualAMRUL Group 7 SG1HOPAR sg1HandoverParms SG2HOPAR sg2HandoverParms SG3HOPAR sg3HandoverParms SG4HOPAR sg4HandoverParms SG5HOPAR sg5HandoverParms SG6HOPAR sg6HandoverParms SG7HOPAR sg7HandoverParms SG8HOPAR sg8HandoverParms SG9HOPAR sg9HandoverParms SG10HOPAR sg10HandoverParms SG11HOPAR sg11HandoverParms SG12HOPAR sg12HandoverParms SG13HOPAR sg13HandoverParms SG14HOPAR sg14HandoverParms SG1PCPAR sg1PowerControlParms SG2PCPAR sg2PowerControlParms SG3PCPAR sg3PowerControlParms SG4PCPAR sg4PowerControlParms SG5PCPAR sg5PowerControlParms SG6PCPAR sg6PowerControlParms SG7PCPAR sg7PowerControlParms SG8PCPAR sg8PowerControlParms SG9PCPAR sg9PowerControlParms SG10PCPAR Sg10PowerControlParms SG11PCPAR sg11PowerControlParms SG12PCPAR sg12PowerControlParms SG13PCPAR sg13PowerControlParms SG14PCPAR sg14PowerControlParms Group 8 RADIOMG radioMeasGran RADIOMR radioMeasRep Group 9 BCCHFREQTD bcchFrequencyTD Group 10 A30808-X3247-L230-3-7619 1785 Commands Base Station Controller CML:BSC HOLTHQUDLTD hoLowerThresholdQualDLTD HOLTHQUULTD hoLowerThresholdQualULTD 1786 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Special Parameter Values - Group 1 Group 1 BCCHFREQ = bcchFrequency The formula to retrieve the Uplink (Fu) and Downlink (Fd) frequencies is the following: Range: 1-124 for P-GSM 900 (Tab. 6.1) 0-124, 975-1023 for E-GSM 900 (Tab. 6.2, Tab. 6.3) 512-885 for DCS 1800 (Tab. 6.4) 955-974 for GSM-R (Tab. 6.5) 512-810 for PCS 1900 (Tab. 6.6) 128-251 for GSM 850 (Tab. 6.7) Frequency Band Type ARFCN (N) Fu Fd P-GSM 900 1-124 Fu(N) = 890.2 + 0.2*(N-1) Fd(N)=Fu(N)+45 E-GSM 900 0-124 Fu(N) = 890.0 + 0.2*N Fd(N)=Fu(N)+45 E-GSM 900 975-1023 Fu(N) = 880.2 + 0.2*(N-975) Fd(N)=Fu(N)+45 DCS 1800 512-885 Fu(N) = 1710.2 + 0.2*(N-512) Fd(N)=Fu(N)+95 GSM-R 955-974 Fu(N) = 876.2 + 0.2*(N-955) Fd(N)=Fu(N)+45 PCS 1900 512-810 Fu(N) = 1850.2 + 0.2*(N-512) Fd(N)=Fu(N)+80 GSM 850 128-251 Fu(N) = 824.2 + 0.2*(N-128) Fd(N)=Fu(N)+45 Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) 1 0001 890.2 935.2 2 0002 890.4 935.4 3 0003 890.6 935.6 4 0004 890.8 935.8 5 0005 891.0 936.0 6 0006 891.2 936.2 7 0007 891.4 936.4 8 0008 891.6 936.6 9 0009 891.8 936.8 10 000A 892.0 937.0 11 000B 892.2 937.2 12 000C 892.4 937.4 13 000D 892.6 937.6 14 000E 892.8 937.8 15 000F 893.0 938.0 16 0010 893.2 938.2 17 0011 893.4 938.4 18 0012 893.6 938.6 19 0013 893.8 938.8 20 0014 894.0 939.0 21 0015 894.2 939.2 22 0016 894.4 939.4 23 0017 894.6 939.6 24 0018 894.8 939.8 25 0019 895.0 940.0 26 001A 895.2 940.2 27 001B 895.4 940.4 28 001C 895.6 940.6 29 001D 895.8 940.8 30 001E 896.0 941.0 Tab. 6.1 Frequency values for P-GSM 900 A30808-X3247-L230-3-7619 1787 Commands Base Station Controller CML:BSC 31 001F 896.2 941.2 32 0020 896.4 941.4 33 0021 896.6 941.6 34 0022 896.8 941.8 35 0023 897.0 942.0 36 0024 897.2 942.2 37 0025 897.4 942.4 38 0026 897.6 942.6 39 0027 897.8 942.8 40 0028 898.0 943.0 41 0029 898.2 943.2 42 002A 898.4 943.4 43 002B 898.6 943.6 44 002C 898.8 943.8 45 002D 899.0 944.0 46 002E 899.2 944.2 47 002F 899.4 944.4 48 0030 899.6 944.6 49 0031 899.8 944.8 50 0032 900.0 945.0 51 0033 900.2 945.2 52 0034 900.4 945.4 53 0035 900.6 945.6 54 0036 900.8 945.8 55 0037 901.0 946.0 56 0038 901.2 946.2 57 0039 901.4 946.4 58 003A 901.6 946.6 59 003B 901.8 946.8 60 003C 902.0 947.0 61 003D 902.2 947.2 62 003E 902.4 947.4 63 003F 902.6 947.6 64 0040 902.8 947.8 65 0041 903.0 948.0 66 0042 903.2 948.2 67 0043 903.4 948.4 68 0044 903.6 948.6 69 0045 903.8 948.8 70 0046 904.0 949.0 71 0047 904.2 949.2 72 0048 904.4 949.4 73 0049 904.6 949.6 74 004A 904.8 949.8 75 004B 905.0 950.0 76 004C 905.2 950.2 77 004D 905.4 950.4 78 004E 905.6 950.6 79 004F 905.8 950.8 80 0050 906.0 951.0 81 0051 906.2 951.2 82 0052 906.4 951.4 83 0053 906.6 951.6 84 0054 906.8 951.8 85 0055 907.0 952.0 86 0056 907.2 952.2 87 0057 907.4 952.4 88 0058 907.6 952.6 89 0059 907.8 952.8 90 005A 908.0 953.0 91 005B 908.2 953.2 92 005C 908.4 953.4 93 005D 908.6 953.6 94 005E 908.8 953.8 95 005F 909.0 954.0 96 0060 909.2 954.2 Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) Tab. 6.1 Frequency values for P-GSM 900 1788 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 97 0061 909.4 954.4 98 0062 909.6 954.6 99 0063 909.8 954.8 100 0064 910.0 955.0 101 0065 910.2 955.2 102 0066 910.4 955.4 103 0067 910.6 955.6 104 0068 910.8 955.8 105 0069 911.0 956.0 106 006A 911.2 956.2 107 006B 911.4 956.4 108 006C 911.6 956.6 109 006D 911.8 956.8 110 006E 912.0 957.0 111 006F 912.2 957.2 112 0070 912.4 957.4 113 0071 912.6 957.6 114 0072 912.8 957.8 115 0073 913.0 958.0 116 0074 913.2 958.2 117 0075 913.4 958.4 118 0076 913.6 958.6 119 0077 913.8 958.8 120 0078 914.0 959.0 121 0079 914.2 959.2 122 007A 914.4 959.4 123 007B 914.6 959.6 124 007C 914.8 959.8 Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) 0 0000 890.0 935.0 1 0001 890.2 935.2 2 0002 890.4 935.4 3 0003 890.6 935.6 4 0004 890.8 935.8 5 0005 891.0 936.0 6 0006 891.2 936.2 7 0007 891.4 936.4 8 0008 891.6 936.6 9 0009 891.8 936.8 10 000A 892.0 937.0 11 000B 892.2 937.2 12 000C 892.4 937.4 13 000D 892.6 937.6 14 000E 892.8 937.8 15 000F 893.0 938.0 16 0010 893.2 938.2 17 0011 893.4 938.4 18 0012 893.6 938.6 19 0013 893.8 938.8 20 0014 894.0 939.0 21 0015 894.2 939.2 22 0016 894.4 939.4 23 0017 894.6 939.6 24 0018 894.8 939.8 25 0019 895.0 940.0 26 001A 895.2 940.2 27 001B 895.4 940.4 Tab. 6.2 Frequency values for E-GSM 900 (from 0 to 124) Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) Tab. 6.1 Frequency values for P-GSM 900 A30808-X3247-L230-3-7619 1789 Commands Base Station Controller CML:BSC 28 001C 895.6 940.6 29 001D 895.8 940.8 30 001E 896.0 941.0 31 001F 896.2 941.2 32 0020 896.4 941.4 33 0021 896.6 941.6 34 0022 896.8 941.8 35 0023 897.0 942.0 36 0024 897.2 942.2 37 0025 897.4 942.4 38 0026 897.6 942.6 39 0027 897.8 942.8 40 0028 898.0 943.0 41 0029 898.2 943.2 42 002A 898.4 943.4 43 002B 898.6 943.6 44 002C 898.8 943.8 45 002D 899.0 944.0 46 002E 899.2 944.2 47 002F 899.4 944.4 48 0030 899.6 944.6 49 0031 899.8 944.8 50 0032 900.0 945.0 51 0033 900.2 945.2 52 0034 900.4 945.4 53 0035 900.6 945.6 54 0036 900.8 945.8 55 0037 901.0 946.0 56 0038 901.2 946.2 57 0039 901.4 946.4 58 003A 901.6 946.6 59 003B 901.8 946.8 60 003C 902.0 947.0 61 003D 902.2 947.2 62 003E 902.4 947.4 63 003F 902.6 947.6 64 0040 902.8 947.8 65 0041 903.0 948.0 66 0042 903.2 948.2 67 0043 903.4 948.4 68 0044 903.6 948.6 69 0045 903.8 948.8 70 0046 904.0 949.0 71 0047 904.2 949.2 72 0048 904.4 949.4 73 0049 904.6 949.6 74 004A 904.8 949.8 75 004B 905.0 950.0 76 004C 905.2 950.2 77 004D 905.4 950.4 78 004E 905.6 950.6 79 004F 905.8 950.8 80 0050 906.0 951.0 81 0051 906.2 951.2 82 0052 906.4 951.4 83 0053 906.6 951.6 84 0054 906.8 951.8 85 0055 907.0 952.0 86 0056 907.2 952.2 87 0057 907.4 952.4 88 0058 907.6 952.6 89 0059 907.8 952.8 90 005A 908.0 953.0 91 005B 908.2 953.2 92 005C 908.4 953.4 93 005D 908.6 953.6 Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) Tab. 6.2 Frequency values for E-GSM 900 (from 0 to 124) 1790 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 94 005E 908.8 953.8 95 005F 909.0 954.0 96 0060 909.2 954.2 97 0061 909.4 954.4 98 0062 909.6 954.6 99 0063 909.8 954.8 100 0064 910.0 955.0 101 0065 910.2 955.2 102 0066 910.4 955.4 103 0067 910.6 955.6 104 0068 910.8 955.8 105 0069 911.0 956.0 106 006A 911.2 956.2 107 006B 911.4 956.4 108 006C 911.6 956.6 109 006D 911.8 956.8 110 006E 912.0 957.0 111 006F 912.2 957.2 112 0070 912.4 957.4 113 0071 912.6 957.6 114 0072 912.8 957.8 115 0073 913.0 958.0 116 0074 913.2 958.2 117 0075 913.4 958.4 118 0076 913.6 958.6 119 0077 913.8 958.8 120 0078 914.0 959.0 121 0079 914.2 959.2 122 007A 914.4 959.4 123 007B 914.6 959.6 124 007C 914.8 959.8 Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) 975 03CF 880.2 925.2 976 03D0 880.4 925.4 977 03D1 880.6 925.6 978 03D2 880.8 925.8 979 03D3 881.0 926.0 980 03D4 881.2 926.2 981 03D5 881.4 926.4 982 03D6 881.6 926.6 983 03D7 881.8 926.8 984 03D8 882.0 927.0 985 03D9 882.2 927.2 986 03DA 882.4 927.4 987 03DB 882.6 927.6 988 03DC 882.8 927.8 989 03DD 883.0 928.0 990 03DE 883.2 928.2 991 03DF 883.4 928.4 992 03E0 883.6 928.6 993 03E1 883.8 928.8 994 03E2 884.0 929.0 995 03E3 884.2 929.2 996 03E4 884.4 929.4 997 03E5 884.6 929.6 998 03E6 884.8 929.8 Tab. 6.3 Frequency values for E-GSM 900 (from 975 to 1023) Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) Tab. 6.2 Frequency values for E-GSM 900 (from 0 to 124) A30808-X3247-L230-3-7619 1791 Commands Base Station Controller CML:BSC 999 03E7 885.0 930.0 1000 03E8 885.2 930.2 1001 03E9 885.4 930.4 1002 03EA 885.6 930.6 1003 03EB 885.8 930.8 1004 03EC 886.0 931.0 1005 03ED 886.2 931.2 1006 03EE 886.4 931.4 1007 03EF 886.6 931.6 1008 03F0 886.8 931.8 1009 03F1 887.0 932.0 1010 03F2 887.2 932.2 1011 03F3 887.4 932.4 1012 03F4 887.6 932.6 1013 03F5 887.8 932.8 1014 03F6 888.0 933.0 1015 03F7 888.2 933.2 1016 03F8 888.4 933.4 1017 03F9 888.6 933.6 1018 03FA 888.8 933.8 1019 03FB 889.0 934.0 1020 03FC 889.2 934.2 1021 03FD 889.4 934.4 1022 03FE 889.6 934.6 1023 03FF 889.8 934.8 Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) 512 0200 1710.2 1805.2 513 0201 1710.4 1805.4 514 0202 1710.6 1805.6 515 0203 1710.8 1805.8 516 0204 1711.0 1806.0 517 0205 1711.2 1806.2 518 0206 1711.4 1806.4 519 0207 1711.6 1806.6 520 0208 1711.8 1806.8 521 0209 1712.0 1807.0 522 020A 1712.2 1807.2 523 020B 1712.4 1807.4 524 020C 1712.6 1807.6 525 020D 1712.8 1807.8 526 020E 1713.0 1808.0 527 020F 1713.2 1808.2 528 0210 1713.4 1808.4 529 0211 1713.6 1808.6 530 0212 1713.8 1808.8 531 0213 1714.0 1809.0 532 0214 1714.2 1809.2 533 0215 1714.4 1809.4 534 0216 1714.6 1809.6 535 0217 1714.8 1809.8 536 0218 1715.0 1810.0 537 0219 1715.2 1810.2 538 021A 1715.4 1810.4 539 021B 1715.6 1810.6 540 021C 1715.8 1810.8 541 021D 1716.0 1811.0 Tab. 6.4 Frequency values for DCS 1800 Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) Tab. 6.3 Frequency values for E-GSM 900 (from 975 to 1023) 1792 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 542 021E 1716.2 1811.2 543 021F 1716.4 1811.4 544 0220 1716.6 1811.6 545 0221 1716.8 1811.8 546 0222 1717.0 1812.0 547 0223 1717.2 1812.2 548 0224 1717.4 1812.4 549 0225 1717.6 1812.6 550 0226 1717.8 1812.8 551 0227 1718.0 1813.0 552 0228 1718.2 1813.2 553 0229 1718.4 1813.4 554 022A 1718.6 1813.6 555 022B 1718.8 1813.8 556 022C 1719.0 1814.0 557 022D 1719.2 1814.2 558 022E 1719.4 1814.4 559 022F 1719.6 1814.6 560 0230 1719.8 1814.8 561 0231 1720.0 1815.0 562 0232 1720.2 1815.2 563 0233 1720.4 1815.4 564 0234 1720.6 1815.6 565 0235 1720.8 1815.8 566 0236 1721.0 1816.0 567 0237 1721.2 1816.2 568 0238 1721.4 1816.4 569 0239 1721.6 1816.6 570 023A 1721.8 1816.8 571 023B 1722.0 1817.0 572 023C 1722.2 1817.2 573 023D 1722.4 1817.4 574 023E 1722.6 1817.6 575 023F 1722.8 1817.8 576 0240 1723.0 1818.0 577 0241 1723.2 1818.2 578 0242 1723.4 1818.4 579 0243 1723.6 1818.6 580 0244 1723.8 1818.8 581 0245 1724.0 1819.0 582 0246 1724.2 1819.2 583 0247 1724.4 1819.4 584 0248 1724.6 1819.6 585 0249 1724.8 1819.8 586 024A 1725.0 1820.0 587 024B 1725.2 1820.2 588 024C 1725.4 1820.4 589 024D 1725.6 1820.6 590 024E 1725.8 1820.8 591 024F 1726.0 1821.0 592 0250 1726.2 1821.2 593 0251 1726.4 1821.4 594 0252 1726.6 1821.6 595 0253 1726.8 1821.8 596 0254 1727.0 1822.0 597 0255 1727.2 1822.2 598 0256 1727.4 1822.4 599 0257 1727.6 1822.6 600 0258 1727.8 1822.8 601 0259 1728.0 1823.0 602 025A 1728.2 1823.2 603 025B 1728.4 1823.4 604 025C 1728.6 1823.6 605 025D 1728.8 1823.8 606 025E 1729.0 1824.0 607 025F 1729.2 1824.2 Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) Tab. 6.4 Frequency values for DCS 1800 A30808-X3247-L230-3-7619 1793 Commands Base Station Controller CML:BSC 608 0260 1729.4 1824.4 609 0261 1729.6 1824.6 610 0262 1729.8 1824.8 611 0263 1730.0 1825.0 612 0264 1730.2 1825.2 613 0265 1730.4 1825.4 614 0266 1730.6 1825.6 615 0267 1730.8 1825.8 616 0268 1731.0 1826.0 617 0269 1731.2 1826.2 618 026A 1731.4 1826.4 619 026B 1731.6 1826.6 620 026C 1731.8 1826.8 621 026D 1732.0 1827.0 622 026E 1732.2 1827.2 623 026F 1732.4 1827.4 624 0270 1732.6 1827.6 625 0271 1732.8 1827.8 626 0272 1733.0 1828.0 627 0273 1733.2 1828.2 628 0274 1733.4 1828.4 629 0275 1733.6 1828.6 630 0276 1733.8 1828.8 631 0277 1734.0 1829.0 632 0278 1734.2 1829.2 633 0279 1734.4 1829.4 634 027A 1734.6 1829.6 635 027B 1734.8 1829.8 636 027C 1735.0 1830.0 637 027D 1735.2 1830.2 638 027E 1735.4 1830.4 639 027F 1735.6 1830.6 640 0280 1735.8 1830.8 641 0281 1736.0 1831.0 642 0282 1736.2 1831.2 643 0283 1736.4 1831.4 644 0284 1736.6 1831.6 645 0285 1736.8 1831.8 646 0286 1737.0 1832.0 647 0287 1737.2 1832.2 648 0288 1737.4 1832.4 649 0289 1737.6 1832.6 650 028A 1737.8 1832.8 651 028B 1738.0 1833.0 652 028C 1738.2 1833.2 653 028D 1738.4 1833.4 654 028E 1738.6 1833.6 655 028F 1738.8 1833.8 656 0290 1739.0 1834.0 657 0291 1739.2 1834.2 658 0292 1739.4 1834.4 659 0293 1739.6 1834.6 660 0294 1739.8 1834.8 661 0295 1740.0 1835.0 662 0296 1740.2 1835.2 663 0297 1740.4 1835.4 664 0298 1740.6 1835.6 665 0299 1740.8 1835.8 666 029A 1741.0 1836.0 667 029B 1741.2 1836.2 668 029C 1741.4 1836.4 669 029D 1741.6 1836.6 670 029E 1741.8 1836.8 671 029F 1742.0 1837.0 672 02A0 1742.2 1837.2 673 02A1 1742.4 1837.4 Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) Tab. 6.4 Frequency values for DCS 1800 1794 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 674 02A2 1742.6 1837.6 675 02A3 1742.8 1837.8 676 02A4 1743.0 1838.0 677 02A5 1743.2 1838.2 678 02A6 1743.4 1838.4 679 02A7 1743.6 1838.6 680 02A8 1743.8 1838.8 681 02A9 1744.0 1839.0 682 02AA 1744.2 1839.2 683 02AB 1744.4 1839.4 684 02AC 1744.6 1839.6 685 02AD 1744.8 1839.8 686 02AE 1745.0 1840.0 687 02AF 1745.2 1840.2 688 02B0 1745.4 1840.4 689 02B1 1745.6 1840.6 690 02B2 1745.8 1840.8 691 02B3 1746.0 1841.0 692 02B4 1746.2 1841.2 693 02B5 1746.4 1841.4 694 02B6 1746.6 1841.6 695 02B7 1746.8 1841.8 696 02B8 1747.0 1842.0 697 02B9 1747.2 1842.2 698 02BA 1747.4 1842.4 699 02BB 1747.6 1842.6 700 02BC 1747.8 1842.8 701 02BD 1748.0 1843.0 702 02BE 1748.2 1843.2 703 02BF 1748.4 1843.4 704 02C0 1748.6 1843.6 705 02C1 1748.8 1843.8 706 02C2 1749.0 1844.0 707 02C3 1749.2 1844.2 708 02C4 1749.4 1844.4 709 02C5 1749.6 1844.6 710 02C6 1749.8 1844.8 711 02C7 1750.0 1845.0 712 02C8 1750.2 1845.2 713 02C9 1750.4 1845.4 714 02CA 1750.6 1845.6 715 02CB 1750.8 1845.8 716 02CC 1751.0 1846.0 717 02CD 1751.2 1846.2 718 02CE 1751.4 1846.4 719 02CF 1751.6 1846.6 720 02D0 1751.8 1846.8 721 02D1 1752.0 1847.0 722 02D2 1752.2 1847.2 723 02D3 1752.4 1847.4 724 02D4 1752.6 1847.6 725 02D5 1752.8 1847.8 726 02D6 1753.0 1848.0 727 02D7 1753.2 1848.2 728 02D8 1753.4 1848.4 729 02D9 1753.6 1848.6 730 02DA 1753.8 1848.8 731 02DB 1754.0 1849.0 732 02DC 1754.2 1849.2 733 02DD 1754.4 1849.4 734 02DE 1754.6 1849.6 735 02DF 1754.8 1849.8 736 02E0 1755.0 1850.0 737 02E1 1755.2 1850.2 738 02E2 1755.4 1850.4 739 02E3 1755.6 1850.6 Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) Tab. 6.4 Frequency values for DCS 1800 A30808-X3247-L230-3-7619 1795 Commands Base Station Controller CML:BSC 740 02E4 1755.8 1850.8 741 02E5 1756.0 1851.0 742 02E6 1756.2 1851.2 743 02E7 1756.4 1851.4 744 02E8 1756.6 1851.6 745 02E9 1756.8 1851.8 746 02EA 1757.0 1852.0 747 02EB 1757.2 1852.2 748 02EC 1757.4 1852.4 749 02ED 1757.6 1852.6 750 02EE 1757.8 1852.8 751 02EF 1758.0 1853.0 752 02F0 1758.2 1853.2 753 02F1 1758.4 1853.4 754 02F2 1758.6 1853.6 755 02F3 1758.8 1853.8 756 02F4 1759.0 1854.0 757 02F5 1759.2 1854.2 758 02F6 1759.4 1854.4 759 02F7 1759.6 1854.6 760 02F8 1759.8 1854.8 761 02F9 1760.0 1855.0 762 02FA 1760.2 1855.2 763 02FB 1760.4 1855.4 764 02FC 1760.6 1855.6 765 02FD 1760.8 1855.8 766 02FE 1761.0 1856.0 767 02FF 1761.2 1856.2 768 0300 1761.4 1856.4 769 0301 1761.6 1856.6 770 0302 1761.8 1856.8 771 0303 1762.0 1857.0 772 0304 1762.2 1857.2 773 0305 1762.4 1857.4 774 0306 1762.6 1857.6 775 0307 1762.8 1857.8 776 0308 1763.0 1858.0 777 0309 1763.2 1858.2 778 030A 1763.4 1858.4 779 030B 1763.6 1858.6 780 030C 1763.8 1858.8 781 030D 1764.0 1859.0 782 030E 1764.2 1859.2 783 030F 1764.4 1859.4 784 0310 1764.6 1859.6 785 0311 1764.8 1859.8 786 0312 1765.0 1860.0 787 0313 1765.2 1860.2 788 0314 1765.4 1860.4 789 0315 1765.6 1860.6 790 0316 1765.8 1860.8 791 0317 1766.0 1861.0 792 0318 1766.2 1861.2 793 0319 1766.4 1861.4 794 031A 1766.6 1861.6 795 031B 1766.8 1861.8 796 031C 1767.0 1862.0 797 031D 1767.2 1862.2 798 031E 1767.4 1862.4 799 031F 1767.6 1862.6 800 0320 1767.8 1862.8 801 0321 1768.0 1863.0 802 0322 1768.2 1863.2 803 0323 1768.4 1863.4 804 0324 1768.6 1863.6 805 0325 1768.8 1863.8 Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) Tab. 6.4 Frequency values for DCS 1800 1796 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 806 0326 1769.0 1864.0 807 0327 1769.2 1864.2 808 0328 1769.4 1864.4 809 0329 1769.6 1864.6 810 032A 1769.8 1864.8 811 032B 1770.0 1865.0 812 032C 1770.2 1865.2 813 032D 1770.4 1865.4 814 032E 1770.6 1865.6 815 032F 1770.8 1865.8 816 0330 1771.0 1866.0 817 0331 1771.2 1866.2 818 0332 1771.4 1866.4 819 0333 1771.6 1866.6 820 0334 1771.8 1866.8 821 0335 1772.0 1867.0 822 0336 1772.2 1867.2 823 0337 1772.4 1867.4 824 0338 1772.6 1867.6 825 0339 1772.8 1867.8 826 033A 1773.0 1868.0 827 033B 1773.2 1868.2 828 033C 1773.4 1868.4 829 033D 1773.6 1868.6 830 033E 1773.8 1868.8 831 033F 1774.0 1869.0 832 0340 1774.2 1869.2 833 0341 1774.4 1869.4 834 0342 1774.6 1869.6 835 0343 1774.8 1869.8 836 0344 1775.0 1870.0 837 0345 1775.2 1870.2 838 0346 1775.4 1870.4 839 0347 1775.6 1870.6 840 0348 1775.8 1870.8 841 0349 1776.0 1871.0 842 034A 1776.2 1871.2 843 034B 1776.4 1871.4 844 034C 1776.6 1871.6 845 034D 1776.8 1871.8 846 034E 1777.0 1872.0 847 034F 1777.2 1872.2 848 0350 1777.4 1872.4 849 0351 1777.6 1872.6 850 0352 1777.8 1872.8 851 0353 1778.0 1873.0 852 0354 1778.2 1873.2 853 0355 1778.4 1873.4 854 0356 1778.6 1873.6 855 0357 1778.8 1873.8 856 0358 1779.0 1874.0 857 0359 1779.2 1874.2 858 035A 1779.4 1874.4 859 035B 1779.6 1874.6 860 035C 1779.8 1874.8 861 035D 1780.0 1875.0 862 035E 1780.2 1875.2 863 035F 1780.4 1875.4 864 0360 1780.6 1875.6 865 0361 1780.8 1875.8 866 0362 1781.0 1876.0 867 0363 1781.2 1876.2 868 0364 1781.4 1876.4 869 0365 1781.6 1876.6 870 0366 1781.8 1876.8 871 0367 1782.0 1877.0 Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) Tab. 6.4 Frequency values for DCS 1800 A30808-X3247-L230-3-7619 1797 Commands Base Station Controller CML:BSC 872 0368 1782.2 1877.2 873 0369 1782.4 1877.4 874 036A 1782.6 1877.6 875 036B 1782.8 1877.8 876 036C 1783.0 1878.0 877 036D 1783.2 1878.2 878 036E 1783.4 1878.4 879 036F 1783.6 1878.6 880 0370 1783.8 1878.8 881 0371 1784.0 1879.0 882 0372 1784.2 1879.2 883 0373 1784.4 1879.4 884 0374 1784.6 1879.6 885 0375 1784.8 1879.8 Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) 955 03BB 876.2 921.2 956 03BC 876.4 921.4 957 03BD 876.6 921.6 958 03BE 876.8 921.8 959 03BF 877.0 922.0 960 03C0 877.2 922.2 961 03C1 877.4 922.4 962 03C2 877.6 922.6 963 03C3 877.8 922.8 964 03C4 878.0 923.0 965 03C5 878.2 923.2 966 03C6 878.4 923.4 967 03C7 878.6 923.6 968 03C8 878.8 923.8 969 03C9 879.0 924.0 970 03CA 879.2 924.2 971 03CB 879.4 924.4 972 03CC 879.6 924.6 973 03CD 879.8 924.8 974 03CE 880.0 925.0 Tab. 6.5 Frequency values for GSM-R Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) 512 0200 1850.2 1930.2 513 0201 1850.4 1930.4 514 0202 1850.6 1930.6 515 0203 1850.8 1930.8 516 0204 1851.0 1931.0 517 0205 1851.2 1931.2 518 0206 1851.4 1931.4 519 0207 1851.6 1931.6 520 0208 1851.8 1931.8 521 0209 1852.0 1932.0 522 020A 1852.2 1932.2 523 020B 1852.4 1932.4 Tab. 6.6 Frequency values for PCS 1900 Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) Tab. 6.4 Frequency values for DCS 1800 1798 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 524 020C 1852.6 1932.6 525 020D 1852.8 1932.8 526 020E 1853.0 1933.0 527 020F 1853.2 1933.2 528 0210 1853.4 1933.4 529 0211 1853.6 1933.6 530 0212 1853.8 1933.8 531 0213 1854.0 1934.0 532 0214 1854.2 1934.2 533 0215 1854.4 1934.4 534 0216 1854.6 1934.6 535 0217 1854.8 1934.8 536 0218 1855.0 1935.0 537 0219 1855.2 1935.2 538 021A 1855.4 1935.4 539 021B 1855.6 1935.6 540 021C 1855.8 1935.8 541 021D 1856.0 1936.0 542 021E 1856.2 1936.2 543 021F 1856.4 1936.4 544 0220 1856.6 1936.6 545 0221 1856.8 1936.8 546 0222 1857.0 1937.0 547 0223 1857.2 1937.2 548 0224 1857.4 1937.4 549 0225 1857.6 1937.6 550 0226 1857.8 1937.8 551 0227 1858.0 1938.0 552 0228 1858.2 1938.2 553 0229 1858.4 1938.4 554 022A 1858.6 1938.6 555 022B 1858.8 1938.8 556 022C 1859.0 1939.0 557 022D 1859.2 1939.2 558 022E 1859.4 1939.4 559 022F 1859.6 1939.6 560 0230 1859.8 1939.8 561 0231 1860.0 1940.0 562 0232 1860.2 1940.2 563 0233 1860.4 1940.4 564 0234 1860.6 1940.6 565 0235 1860.8 1940.8 566 0236 1861.0 1941.0 567 0237 1861.2 1941.2 568 0238 1861.4 1941.4 569 0239 1861.6 1941.6 570 023A 1861.8 1941.8 571 023B 1862.0 1942.0 572 023C 1862.2 1942.2 573 023D 1862.4 1942.4 574 023E 1862.6 1942.6 575 023F 1862.8 1942.8 576 0240 1863.0 1943.0 577 0241 1863.2 1943.2 578 0242 1863.4 1943.4 579 0243 1863.6 1943.6 580 0244 1863.8 1943.8 581 0245 1864.0 1944.0 582 0246 1864.2 1944.2 583 0247 1864.4 1944.4 584 0248 1864.6 1944.6 585 0249 1864.8 1944.8 586 024A 1865.0 1945.0 587 024B 1865.2 1945.2 588 024C 1865.4 1945.4 589 024D 1865.6 1945.6 Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) Tab. 6.6 Frequency values for PCS 1900 A30808-X3247-L230-3-7619 1799 Commands Base Station Controller CML:BSC 590 024E 1865.8 1945.8 591 024F 1866.0 1946.0 592 0250 1866.2 1946.2 593 0251 1866.4 1946.4 594 0252 1866.6 1946.6 595 0253 1866.8 1946.8 596 0254 1867.0 1947.0 597 0255 1867.2 1947.2 598 0256 1867.4 1947.4 599 0257 1867.6 1947.6 600 0258 1867.8 1947.8 601 0259 1868.0 1948.0 602 025A 1868.2 1948.2 603 025B 1868.4 1948.4 604 025C 1868.6 1948.6 605 025D 1868.8 1948.8 606 025E 1869.0 1949.0 607 025F 1869.2 1949.2 608 0260 1869.4 1949.4 609 0261 1869.6 1949.6 610 0262 1869.8 1949.8 611 0263 1870.0 1950.0 612 0264 1870.2 1950.2 613 0265 1870.4 1950.4 614 0266 1870.6 1950.6 615 0267 1870.8 1950.8 616 0268 1871.0 1951.0 617 0269 1871.2 1951.2 618 026A 1871.4 1951.4 619 026B 1871.6 1951.6 620 026C 1871.8 1951.8 621 026D 1872.0 1952.0 622 026E 1872.2 1952.2 623 026F 1872.4 1952.4 624 0270 1872.6 1952.6 625 0271 1872.8 1952.8 626 0272 1873.0 1953.0 627 0273 1873.2 1953.2 628 0274 1873.4 1953.4 629 0275 1873.6 1953.6 630 0276 1873.8 1953.8 631 0277 1874.0 1954.0 632 0278 1874.2 1954.2 633 0279 1874.4 1954.4 634 027A 1874.6 1954.6 635 027B 1874.8 1954.8 636 027C 1875.0 1955.0 637 027D 1875.2 1955.2 638 027E 1875.4 1955.4 639 027F 1875.6 1955.6 640 0280 1875.8 1955.8 641 0281 1876.0 1956.0 642 0282 1876.2 1956.2 643 0283 1876.4 1956.4 644 0284 1876.6 1956.6 645 0285 1876.8 1956.8 646 0286 1877.0 1957.0 647 0287 1877.2 1957.2 648 0288 1877.4 1957.4 649 0289 1877.6 1957.6 650 028A 1877.8 1957.8 651 028B 1878.0 1958.0 652 028C 1878.2 1958.2 653 028D 1878.4 1958.4 654 028E 1878.6 1958.6 655 028F 1878.8 1958.8 Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) Tab. 6.6 Frequency values for PCS 1900 1800 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 656 0290 1879.0 1959.0 657 0291 1879.2 1959.2 658 0292 1879.4 1959.4 659 0293 1879.6 1959.6 660 0294 1879.8 1959.8 661 0295 1880.0 1960.0 662 0296 1880.2 1960.2 663 0297 1880.4 1960.4 664 0298 1880.6 1960.6 665 0299 1880.8 1960.8 666 029A 1881.0 1961.0 667 029B 1881.2 1961.2 668 029C 1881.4 1961.4 669 029D 1881.6 1961.6 670 029E 1881.8 1961.8 671 029F 1882.0 1962.0 672 02A0 1882.2 1962.2 673 02A1 1882.4 1962.4 674 02A2 1882.6 1962.6 675 02A3 1882.8 1962.8 676 02A4 1883.0 1963.0 677 02A5 1883.2 1963.2 678 02A6 1883.4 1963.4 679 02A7 1883.6 1963.6 680 02A8 1883.8 1963.8 681 02A9 1884.0 1964.0 682 02AA 1884.2 1964.2 683 02AB 1884.4 1964.4 684 02AC 1884.6 1964.6 685 02AD 1884.8 1964.8 686 02AE 1885.0 1965.0 687 02AF 1885.2 1965.2 688 02B0 1885.4 1965.4 689 02B1 1885.6 1965.6 690 02B2 1885.8 1965.8 691 02B3 1886.0 1966.0 692 02B4 1886.2 1966.2 693 02B5 1886.4 1966.4 694 02B6 1886.6 1966.6 695 02B7 1886.8 1966.8 696 02B8 1887.0 1967.0 697 02B9 1887.2 1967.2 698 02BA 1887.4 1967.4 699 02BB 1887.6 1967.6 700 02BC 1887.8 1967.8 701 02BD 1888.0 1968.0 702 02BE 1888.2 1968.2 703 02BF 1888.4 1968.4 704 02C0 1888.6 1968.6 705 02C1 1888.8 1968.8 706 02C2 1889.0 1969.0 707 02C3 1889.2 1969.2 708 02C4 1889.4 1969.4 709 02C5 1889.6 1969.6 710 02C6 1889.8 1969.8 711 02C7 1890.0 1970.0 712 02C8 1890.2 1970.2 713 02C9 1890.4 1970.4 714 02CA 1890.6 1970.6 715 02CB 1890.8 1970.8 716 02CC 1891.0 1971.0 717 02CD 1891.2 1971.2 718 02CE 1891.4 1971.4 719 02CF 1891.6 1971.6 720 02D0 1891.8 1971.8 721 02D1 1892.0 1972.0 Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) Tab. 6.6 Frequency values for PCS 1900 A30808-X3247-L230-3-7619 1801 Commands Base Station Controller CML:BSC 722 02D2 1892.2 1972.2 723 02D3 1892.4 1972.4 724 02D4 1892.6 1972.6 725 02D5 1892.8 1972.8 726 02D6 1893.0 1973.0 727 02D7 1893.2 1973.2 728 02D8 1893.4 1973.4 729 02D9 1893.6 1973.6 730 02DA 1893.8 1973.8 731 02DB 1894.0 1974.0 732 02DC 1894.2 1974.2 733 02DD 1894.4 1974.4 734 02DE 1894.6 1974.6 735 02DF 1894.8 1974.8 736 02E0 1895.0 1975.0 737 02E1 1895.2 1975.2 738 02E2 1895.4 1975.4 739 02E3 1895.6 1975.6 740 02E4 1895.8 1975.8 741 02E5 1896.0 1976.0 742 02E6 1896.2 1976.2 743 02E7 1896.4 1976.4 744 02E8 1896.6 1976.6 745 02E9 1896.8 1976.8 746 02EA 1897.0 1977.0 747 02EB 1897.2 1977.2 748 02EC 1897.4 1977.4 749 02ED 1897.6 1977.6 750 02EE 1897.8 1977.8 751 02EF 1898.0 1978.0 752 02F0 1898.2 1978.2 753 02F1 1898.4 1978.4 754 02F2 1898.6 1978.6 755 02F3 1898.8 1978.8 756 02F4 1899.0 1979.0 757 02F5 1899.2 1979.2 758 02F6 1899.4 1979.4 759 02F7 1899.6 1979.6 760 02F8 1899.8 1979.8 761 02F9 1900.0 1980.0 762 02FA 1900.2 1980.2 763 02FB 1900.4 1980.4 764 02FC 1900.6 1980.6 765 02FD 1900.8 1980.8 766 02FE 1901.0 1981.0 767 02FF 1901.2 1981.2 768 0300 1901.4 1981.4 769 0301 1901.6 1981.6 770 0302 1901.8 1981.8 771 0303 1902.0 1982.0 772 0304 1902.2 1982.2 773 0305 1902.4 1982.4 774 0306 1902.6 1982.6 775 0307 1902.8 1982.8 776 0308 1903.0 1983.0 777 0309 1903.2 1983.2 778 030A 1903.4 1983.4 779 030B 1903.6 1983.6 780 030C 1903.8 1983.8 781 030D 1904.0 1984.0 782 030E 1904.2 1984.2 783 030F 1904.4 1984.4 784 0310 1904.6 1984.6 785 0311 1904.8 1984.8 786 0312 1905.0 1985.0 787 0313 1905.2 1985.2 Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) Tab. 6.6 Frequency values for PCS 1900 1802 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 788 0314 1905.4 1985.4 789 0315 1905.6 1985.6 790 0316 1905.8 1985.8 791 0317 1906.0 1986.0 792 0318 1906.2 1986.2 793 0319 1906.4 1986.4 794 031A 1906.6 1986.6 795 031B 1906.8 1986.8 796 031C 1907.0 1987.0 797 031D 1907.2 1987.2 798 031E 1907.4 1987.4 799 031F 1907.6 1987.6 800 0320 1907.8 1987.8 801 0321 1908.0 1988.0 802 0322 1908.2 1988.2 803 0323 1908.4 1988.4 804 0324 1908.6 1988.6 805 0325 1908.8 1988.8 806 0326 1909.0 1989.0 807 0327 1909.2 1989.2 808 0328 1909.4 1989.4 809 0329 1909.6 1989.6 810 032A 1909.8 1989.8 Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) 128 0080 824.2 869.2 129 0081 824.4 869.4 130 0082 824.6 869.6 131 0083 824.8 869.8 132 0084 825.0 870.0 133 0085 825.2 870.2 134 0086 825.4 870.4 135 0087 825.6 870.6 136 0088 825.8 870.8 137 0089 826.0 871.0 138 008A 826.2 871.2 139 008B 826.4 871.4 140 008C 826.6 871.6 141 008D 826.8 871.8 142 008E 827.0 872.0 143 008F 827.2 872.2 144 0090 827.4 872.4 145 0091 827.6 872.6 146 0092 827.8 872.8 147 0093 828.0 873.0 148 0094 828.2 873.2 149 0095 828.4 873.4 150 0096 828.6 873.6 151 0097 828.8 873.8 152 0098 829.0 874.0 153 0099 829.2 874.2 154 009A 829.4 874.4 155 009B 829.6 874.6 156 009C 829.8 874.8 157 009D 830.0 875.0 158 009E 830.2 875.2 159 009F 830.4 875.4 Tab. 6.7 Frequency values for GSM 850 Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) Tab. 6.6 Frequency values for PCS 1900 A30808-X3247-L230-3-7619 1803 Commands Base Station Controller CML:BSC 160 00A0 830.6 875.6 161 00A1 830.8 875.8 162 00A2 831.0 876.0 163 00A3 831.2 876.2 164 00A4 831.4 876.4 165 00A5 831.6 876.6 166 00A6 831.8 876.8 167 00A7 832.0 877.0 168 00A8 832.2 877.2 169 00A9 832.4 877.4 170 00AA 832.6 877.6 171 00AB 832.8 877.8 172 00AC 833.0 878.0 173 00AD 833.2 878.2 174 00AE 833.4 878.4 175 00AF 833.6 878.6 176 00B0 833.8 878.8 177 00B1 834.0 879.0 178 00B2 834.2 879.2 179 00B3 834.4 879.4 180 00B4 834.6 879.6 181 00B5 834.8 879.8 182 00B6 835.0 880.0 183 00B7 835.2 880.2 184 00B8 835.4 880.4 185 00B9 835.6 880.6 186 00BA 835.8 880.8 187 00BB 836.0 881.0 188 00BC 836.2 881.2 189 00BD 836.4 881.4 190 00BE 836.6 881.6 191 00BF 836.8 881.8 192 00C0 837.0 882.0 193 00C1 837.2 882.2 194 00C2 837.4 882.4 195 00C3 837.6 882.6 196 00C4 837.8 882.8 197 00C5 838.0 883.0 198 00C6 838.2 883.2 199 00C7 838.4 883.4 200 00C8 838.6 883.6 201 00C9 838.8 883.8 202 00CA 839.0 884.0 203 00CB 839.2 884.2 204 00CC 839.4 884.4 205 00CD 839.6 884.6 206 00CE 839.8 884.8 207 00CF 840.0 885.0 208 00D0 840.2 885.2 209 00D1 840.4 885.4 210 00D2 840.6 885.6 211 00D3 840.8 885.8 212 00D4 841.0 886.0 213 00D5 841.2 886.2 214 00D6 841.4 886.4 215 00D7 841.6 886.6 216 00D8 841.8 886.8 217 00D9 842.0 887.0 218 00DA 842.2 887.2 219 00DB 842.4 887.4 220 00DC 842.6 887.6 221 00DD 842.8 887.8 222 00DE 843.0 888.0 223 00DF 843.2 888.2 224 00E0 843.4 888.4 225 00E1 843.6 888.6 Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) Tab. 6.7 Frequency values for GSM 850 1804 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 226 00E2 843.8 888.8 227 00E3 844.0 889.0 228 00E4 844.2 889.2 229 00E5 844.4 889.4 230 00E6 844.6 889.6 231 00E7 844.8 889.8 232 00E8 845.0 890.0 233 00E9 845.2 890.2 234 00EA 845.4 890.4 235 00EB 845.6 890.6 236 00EC 845.8 890.8 237 00ED 846.0 891.0 238 00EE 846.2 891.2 239 00EF 846.4 891.4 240 00F0 846.6 891.6 241 00F1 846.8 891.8 242 00F2 847.0 892.0 243 00F3 847.2 892.2 244 00F4 847.4 892.4 245 00F5 847.6 892.6 246 00F6 847.8 892.8 247 00F7 848.0 893.0 248 00F8 848.2 893.2 249 00F9 848.4 893.4 250 00FA 848.6 893.6 251 00FB 848.8 893.8 Dec. Hex. Fu (MHz) Fd (MHz) Dec. Hex. Fu (MHz) Fd (MHz) Tab. 6.7 Frequency values for GSM 850 A30808-X3247-L230-3-7619 1805 Commands Base Station Controller CML:BSC Special Parameter Values - Group 2 Group 2 HOLTHLVDL: hoLowerThresholdLevDL HOLTHLVUL: hoLowerThresholdLevUL HOTDLINT: hoThresholdLevDLintra HOTULINT: hoThresholdLevULintra LOWTLEVD: pcLowerThresholdLevDL LOWTLEVU: pcLowerThresholdLevUL UPTLEVD: pcUpperThresholdLevDL UPTLEVU: pcUpperThresholdLevUL RXLEVMIN: rxLevMinCell RXLEVMINTD: rxLevMinCellTD Range: 0-63 dBr (Tab. 6.8) Dec. dBm value dBm range Dec. dBmvalue dBm range 0 -110 -|...<= -110 32 -78 -79<...<=-78 1 -109 -110<...<= -109 33 -77 -78<...<=-77 2 -108 -109<...<= -108 34 -76 -77<...<=-76 3 -107 -108<...<= -107 35 -75 -76<...<=-75 4 -106 -107<...<= -106 36 -74 -75<...<=-74 5 -105 -106<...<= -105 37 -73 -74<...<=-73 6 -104 -105<...<= -104 38 -72 -73<...<=-72 7 -103 -104<...<= -103 39 -71 -72<...<=-71 8 -102 -103<...<= -102 40 -70 -71<...<=-70 9 -101 -102<...<= -101 41 -69 -70<...<=-69 10 -100 -101<...<= -100 42 -68 -69<...<=-68 11 -99 -100<...<= -99 43 -67 -68<...<=-67 12 -98 -99<...<= -98 44 -66 -67<...<=-66 13 -97 -98<...<= -97 45 -65 -66<...<=-65 14 -96 -97<...<= -96 46 -64 -65<...<=-64 15 -95 -96<...<= -95 47 -63 -64<...<=-63 16 -94 -95<...<= -94 48 -62 -63<...<=-62 17 -93 -94<...<= -93 49 -61 -62<...<=-61 Tab. 6.8 Values for received signal threshold 1806 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 18 -92 -93<...<= -92 50 -60 -61<...<=-60 19 -91 -92<...<= -91 51 -59 -60<...<=-59 20 -90 -91<...<= -90 52 -58 -59<...<=-58 21 -89 -90<...<= -89 53 -57 -58<...<=-57 22 -88 -89<...<= -88 54 -56 -57<...<=-56 23 -87 -88<...<= -87 55 -55 -56<...<=-55 24 -86 -87<...<= -86 56 -54 -55<...<=-54 25 -85 -86<...<= -85 57 -53 -54<...<=-53 26 -84 -85<...<= -84 58 -52 -53<...<=-52 27 -83 -84<...<= -83 59 -51 -52<...<=-51 28 -82 -83<...<= -82 60 -50 -51<...<=-50 29 -81 -82<...<= -81 61 -49 -50<...<=-49 30 -80 -81<...<= -80 62 -48 -49<...<=-48 31 -79 -80<...<= -79 63 -47 -48<...+| Dec. dBm value dBm range Dec. dBmvalue dBm range Tab. 6.8 Values for received signal threshold A30808-X3247-L230-3-7619 1807 Commands Base Station Controller CML:BSC Special Parameter Values - Group 3 Group 3 Handover thresholds: HOLTHQUDL: hoLowerThresholdQualDL (range: 0..7) HOLTHQUUL: hoLowerThresholdQualUL (range: 0..7) LOWTQUAD: pcLowerThresholdQualDL (range: 0..7) LOWTQUAU: pcLowerThresholdQualUL (range: 0..7) UPTQUAD: pcUpperThresholdQualDL (range: 0..7) UPTQUAU: pcUpperThresholdQualUL (range: 0..7) Configuration rules for service independent attributes: HOLTHQUDL > LOWTQUAD > UPTQUAD HOLTHQUUL > LOWTQUAU > UPTQUAU Configuration rules for SGXHOPAR and/or the SGXPCPAR (X = 1..10) service dependent attributes: When the service dependent SGXHOPAR and/or the SGXPCPAR attributes are different fromNULL, the configuration rules above apply to the fields of the SGXHOPAR and SGXPCPAR attributes. See in Group 7 description of Service Groups and service dependent attributes. Example 1: if SG3HOPAR is different from NULL value and SG3PCPAR attribute is equal to NULL value: SG3HOPAR.hoLowerThresholdQualDL > LOWTQUAD > UPTQUAD SG3HOPAR.hoLowerThresholdQualUL > LOWTQUAU > UPTQUAU Example 2: if SG5HOPAR is equal to NULL value and SG5PCPAR attribute is different from NULL value: HOLTHQUDL > SG5PCPAR.pcLowerThresholdQualDL > > SG5PCPAR.pcUpperThresholdQualDL HOLTHQUUL > SG5PCPAR.pcLowerThresholdQualUL > > SG5PCPAR.pcUpperThresholdQualUL Example 3: if both SG10HOPAR and SG10PCPAR are different from NULL value: SG10HOPAR.hoLowerThresholdQualDL > > SG10PCPAR.pcLowerThresholdQualDL SG10PCPAR.pcLowerThresholdQualDL > > SG10PCPAR.pcUpperThresholdQualDL SG10HOPAR.hoLowerThresholdQualUL > > SG10PCPAR.pcLowerThresholdQualUL SG10PCPAR.pcLowerThresholdQualUL > > SG10PCPAR.pcUpperThresholdQualUL Rate 14.4 kbit/s, 9.6 kbit/s upgrade/downgrade thresholds: RUGRDL: rateUpgradeDownlink (range: 0..5) RUGRUL: rateUpgradeUplink (range: 0..5) RDGRDL: rateDowngradeDownlink (range: 1..6) RDGRUL: rateDowngradeUplink (range: 1..6) RHOLTQDL: rateHoLowerThresholdQualDownlink (range: 2..7) RHOLTQUL: rateHoLowerThresholdQualUplink (range: 2..7) Configuration rules for service independent attributes: RUGRDL < RDGRDL < RHOLTQDL 1808 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller RUGRUL < RDGRUL < RHOLTQUL Configuration rules for SGXHOPAR (X = 7..10) service dependent attributes: When the service dependent SGXHOPAR is different from NULL, the configuration rules above apply to the fields of the SGXHOPAR attribute. See in Group 7 description of Service Groups and service dependent attributes. Example: if SG7HOPAR is different from NULL value: RUGRDL > RDGRDL > SG7HOPAR.rateHoLowerThresholdQualDL RUGRUL > RDGRUL > SG7HOPAR.rateHoLowerThresholdQualUL. Threshold Signal Quality Range for Bit Error Rate 00 BER < 0,2 % 01 0,2 % < BER < 0,4 % 02 0,4 % < BER < 0,8 % 03 0,8 % < BER < 1,6 % 04 1,6 % < BER < 3,2 % 05 3,2 % < BER < 6,4 % 06 6,4 % < BER < 12,8 % 07 12,8 % < BER Tab. 6.9 Relationship between Signal Quality and BER A30808-X3247-L230-3-7619 1809 Commands Base Station Controller CML:BSC Special Parameter Values - Group 4 Group 4 MSTXPMAXGSM: msTxPwrMaxGsm MSTXPMAXDCS: msTxPwrMaxDcs MSTXPMAXPCS: msTxPwrMaxPcs MSTXPMAXUMTS: msTxPwrMaxUmts Range: 2-15 for GSM 900, GSM 850 and R-GSM (Tab. 6.10) 0-15 for DCS 1800 (Tab. 6.11) 0-15, 30-31 for PCS 1900 (Tab. 6.12) 0-19 for UMTS (Tab. 6.13) Dec. (Hex.) Power Level 02 (02) 39 dBm 03 (03) 37 dBm 04 (04) 35 dBm 05 (05) 33 dBm 06 (06) 31 dBm 07 (07) 29 dBm 08 (08) 27 dBm 09 (09) 25 dBm 10 (0A) 23 dBm 11 (0B) 21 dBm 12 (0C) 19 dBm 13 (0D) 17 dBm 14 (0E) 15 dBm 15 (0F) 13 dBm Tab. 6.10 Values for GSM and R-GSM Dec. (Hex.) Power Level 00 (00) 30 dBm 01 (01) 28 dBm 02 (02) 26 dBm 03 (03) 24 dBm Tab. 6.11 Values for DCS 1800 1810 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller 04 (04) 22 dBm 05 (05) 20 dBm 06 (06) 18 dBm 07 (07) 16 dBm 08 (08) 14 dBm 09 (09) 12 dBm 10 (0A) 10 dBm 11 (0B) 08 dBm 12 (0C) 06 dBm 13 (0D) 04 dBm 14 (0E) 02 dBm 15 (0F) 00 dBm Dec. (Hex.) Power Level 00 (00) 30 dBm 01 (01) 28 dBm 02 (02) 26 dBm 03 (03) 24 dBm 04 (04) 22 dBm 05 (05) 20 dBm 06 (06) 18 dBm 07 (07) 16 dBm 08 (08) 14 dBm 09 (09) 12 dBm 10 (0A) 10 dBm 11 (0B) 08 dBm 12 (0C) 06 dBm 13 (0D) 04 dBm 14 (0E) 02 dBm 15 (0F) 00 dBm 30 (1E) 33 dBm 31 (1F) 32 dBm Tab. 6.12 Values for PCS 1900 Dec. (Hex.) Power Level Tab. 6.11 Values for DCS 1800 A30808-X3247-L230-3-7619 1811 Commands Base Station Controller CML:BSC Dec. (Hex.) Power Level 00 (00) 43 dBm 01 (01) 41 dBm 02 (02) 39 dBm 03 (03) 37 dBm 04 (04) 35 dBm 05 (05) 33 dBm 06 (06) 31 dBm 07 (07) 29 dBm 08 (08) 27 dBm 09 (09) 25 dBm 10 (0A) 23 dBm 11 (0B) 21 dBm 12 (0C) 19 dBm 13 (0D) 17 dBm 14 (0E) 15 dBm 15 (0F) 13 dBm 16 (10) 11 dBm 17 (11) 9 dBm 18 (12) 7 dBm 19 (13) 5 dBm Tab. 6.13 Values for UMTS 1812 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Special Parameter Values - Group 5 Group 5 Tab. 6.14 shows the circuit pool number (1 to 48) with the corresponding supported channels and speech coding algorithms. The following O&M parameters are used to enable and define the pooling feature: EPOOL: enablePooling (BSC object) DEFPOOLTYP: defPoolType (PCMA object) POOLTYP: poolType (TSLA object) Pool Number (POOL_<n>) Supported Channels and Speech Coding Algorithms Circuit pool n. 1 FR speech version 1 FR data (12, 6, 3.6 kbit/s) Circuit pool n. 2 HR speech version 1 HR data (6, 3.6 kbit/s) Circuit pool n. 3 FR speech version 1 FR data (12, 6, 3.6 kbit/s) HR speech version 1 HR data (6, 3.6 kbit/s) Circuit pool n. 4 FR speech version 2 FR data (12, 6, 3.6 kbit/s) Circuit pool n. 5 FR speech version 1 FR speech version 2 FR data (12, 6, 3.6 kbit/s) Circuit pool n. 6 FR speech version 2 FR data (12, 6, 3.6 kbit/s) HR speech version 1 HR data (6, 3.6 kbit/s) Circuit pool n. 7 FR speech version 1 FR speech version 2 FR data (12, 6, 3.6 kbit/s) HR speech version 1 HR data (6, 3.6 kbit/s) Circuit pool n. 8 HSCSD max 2 x FR data (12, 6 kbit/s) Circuit pool n. 9 FR data (12, 6, 3.6 kbit/s) HR data (6, 3.6 kbit/s) HSCSD max 2 x FR data (12, 6 kbit/s) Circuit pool n. 10 FR speech version 1 FR speech version 2 FR data (12, 6, 3.6 kbit/s) HR speech version 1 HR data (6, 3.6 kbit/s) HSCSD max 2 x FR data (12, 6 kbit/s) Tab. 6.14 Circuit Pool Coding A30808-X3247-L230-3-7619 1813 Commands Base Station Controller CML:BSC Circuit pool n. 11 HSCSD max 4 x FR data (12, 6 kbit/s) Circuit pool n. 12 FR data (12, 6, 3.6 kbit/s) HR data (6, 3.6 kbit/s) HSCSD max 4 x FR data (12, 6 kbit/s) Circuit pool n. 13 FR speech version 1 FR speech version 2 FR data (12, 6, 3.6 kbit/s) HR speech version 1 HR data (6, 3.6 kbit/s) HSCSD max 4 x FR data (12, 6 kbit/s) Circuit pool n. 14 (not used) HSCSD max 6 x FR data (12, 6 kbit/s) EDGE max 2 x FR data (32.0 kbit/s) Circuit pool n. 15 FR data (14.5 kbit/s) Circuit pool n. 16 HSCSD max 2 x FR data (14.5 kbit/s) EDGE FR data (29.0 kbit/s) Circuit pool n. 17 HSCSD max 4 x FR data (14.5 kbit/s) EDGE max 2 x FR data (29.0 kbit/s) EDGE FR data (43.5 kbit/s) Circuit pool n. 18 FR data (14.5, 12, 6, 3.6 kbit/s) HR data (6, 3.6 kbit/s) HSCSD max 2 x FR data (14.5, 12, 6 kbit/s) EDGE FR data (29.0 kbit/s) Circuit pool n. 19 FR data (14.5, 12, 6, 3.6 kbit/s) HR data (6, 3.6 kbit/s) HSCSD max 4 x FR data (14.5, 12, 6 kbit/s) EDGE max 2 x FR data (29.0 kbit/s) EDGE FR data (43.5 kbit/s) Circuit pool n. 20 FR speech version 1 FR speech version 2 FR data (14.5, 12, 6, 3.6 kbit/s) HR speech version 1 HR data (6, 3.6 kbit/s) Circuit pool n. 21 FR speech version 1 FR speech version 2 FR data (14.5, 12, 6, 3.6 kbit/s) HR speech version 1 HR data (6, 3.6 kbit/s) HSCSD max 2 x FR data (14.5, 12, 6 kbit/s) EDGE FR data (29.0 kbit/s) Pool Number (POOL_<n>) Supported Channels and Speech Coding Algorithms Tab. 6.14 Circuit Pool Coding 1814 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Circuit pool n. 22 FR speech version 1 FR speech version 2 FR data (14.5, 12, 6, 3.6 kbit/s) HR speech version 1 HR data (6, 3.6 kbit/s) HSCSD max 4 x FR data (14.5, 12, 6 kbit/s) EDGE max 2 x FR data (29.0 kbit/s) EDGE FR data (43.5 kbit/s) Circuit pool n. 23 Speech Version 3 Circuit pool n. 24 FR speech version 3 FR data (12, 6, 3.6 kbit/s) HR speech version 3 Circuit pool n. 25 FR speech version 1 FR speech version 2 FR speech version 3 FR data (12, 6, 3.6 kbit/s) HR speech version 3 Circuit pool n. 26 FR speech version 1 FR speech version 2 FR speech version 3 FR data (14.5, 12, 6, 3.6 kbit/s) HR speech version 3 Circuit pool n. 27 FR speech version 1 FR speech version 2 FR speech version 3 FR data (12, 6, 3.6 kbit/s) HR speech version 1 HR speech version 3 HR data (6, 3.6 kbit/s) Circuit pool n. 28 FR speech version 1 FR speech version 2 FR speech version 3 FR data (14.5, 12, 6, 3.6 kbit/s) HR speech version 1 HR speech version 3 HR data (6, 3.6 kbit/s) Circuit pool n. 29 FR speech version 1 FR speech version 2 FR speech version 3 FR data (12, 6, 3.6 kbit/s) HR speech version 1 HR speech version 3 HR data (6, 3.6 kbit/s) HSCSD max 2 * FR data (12, 6 kbit/s) Pool Number (POOL_<n>) Supported Channels and Speech Coding Algorithms Tab. 6.14 Circuit Pool Coding A30808-X3247-L230-3-7619 1815 Commands Base Station Controller CML:BSC Circuit pool n. 30 FR speech version 1 FR speech version 2 FR speech version 3 FR data (14.5, 12, 6, 3.6 kbit/s) HR speech version 1 HR speech version 3 HR data (6, 3.6 kbit/s) HSCSD max 2 * FR data (14.5, 12, 6 kbit/s) EDGE FR data (29 kbit/s) Circuit pool n. 31 FR speech version 1 FR speech version 2 FR speech version 3 FR data (12, 6, 3.6 kbit/s) HR speech version 1 HR speech version 3 HR data (6, 3.6 kbit/s) HSCSD max 4 * FR data (12, 6 kbit/s) Circuit pool n. 32 FR speech version 1 FR speech version 2 FR speech version 3 FR data (14.5, 12, 6, 3.6 kbit/s) HR speech version 1 HR speech version 3 HR data (6, 3.6 kbit/s) HSCSD max 4 * FR data (14.5, 12, 6 kbit/s) EDGE max 2 * FR data (29 kbit/s) EDGE FR data (43.5 kbit/s) Circuit pool n. 33 FR data (14.5, 12, 6, 3.6 kbit/s) HR data (6, 3.6 kbit/s) HSCSD max 4 * FR data (14.5, 12, 6 kbit/s) EDGE max 2 * FR data (29 kbit/s) EDGE FR data (43.5 kbit/s) EDGE max 2 * FR data (32 kbit/s) Circuit pool n. 34 FR speech version 1 FR speech version 2 FR data (14.5, 12, 6, 3.6 kbit/s) HR speech version 1 HR data (6, 3.6 kbit/s) HSCSD max 4 * FR data (14.5, 12, 6 kbit/s) EDGE max 2 * FR data (29 kbit/s) EDGE FR data (43.5 kbit/s) EDGE max 2 * FR data (32 kbit/s) Pool Number (POOL_<n>) Supported Channels and Speech Coding Algorithms Tab. 6.14 Circuit Pool Coding 1816 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Circuit pool n. 35 FR speech version 1 FR speech version 2 FR speech version 3 FR data (14.5, 12, 6, 3.6 kbit/s) HR speech version 1 HR speech version 3 HR data (6, 3.6 kbit/s) HSCSD max 4 * FR data (14.5, 12, 6 kbit/s) EDGE max 2 * FR data (29 kbit/s) EDGE FR data (43.5 kbit/s) EDGE max 2 * FR data (32 kbit/s) Circuit pool n. 42 FR speech version 1 + CTM Circuit pool n. 43 FR speech version 2 + CTM Circuit pool n. 44 FR speech version 1 + CTM FR speech version 2 + CTM Circuit pool n. 45 FR speech version 1 + CTM FR speech version 2 + CTM HR speech version 1 + CTM Circuit pool n. 46 FR speech version 3 + CTM HR speech version 3 + CTM Circuit pool n. 47 FR speech version 1 + CTM FR speech version 2 + CTM FR speech version 3 + CTM HR speech version 3 + CTM Circuit pool n. 48 FR speech version 1 + CTM FR speech version 2 + CTM FR speech version 3 + CTM HR speech version 1 + CTM HR speech version 3 + CTM i When the EPOOL parameter of the BSC object is set to TRUE, if all the TSLAs of a TRAU are set to the NOT-DEFINED value, all TRAC boards of this TRAU go to cold standby state, and the TRAU loses its functionality. Pool Number (POOL_<n>) Supported Channels and Speech Coding Algorithms Tab. 6.14 Circuit Pool Coding A30808-X3247-L230-3-7619 1817 Commands Base Station Controller CML:BSC Special Parameter Values - Group 6 Group 6 HOLTHQAMRDL: hoLowerThresQualAMRDL HOLTHQAMRUL: hoLowerThresQualAMRUL HOTHAMRCDL: hoThresAMRComprDL HOTHAMRCUL: hoThresAMRComprUL HOTHAMRDDL: hoThresAMRDecomprDL HOTHAMRDUL: hoThresAMRDecomprUL LOWTQUAMRDL: pcLowerThresQualAMRDL LOWTQUAMRUL: pcLowerThresQualAMRUL UPTQUAMRDL: pcUpperThresQualAMRDL UPTQUAMRUL: pcUpperThresQualAMRUL The following table shows the conversion of RXQUAL to C/I for database settings related to the above listed parameters: RXQUAL medium RXQUAL calculated C/I 6.88 .... 7 7.00 1 6.63 .... 6.87 6.75 2 6.38 .... 6.62 6.50 4 6.13 .... 6.37 6.25 5 5.88 .... 6.12 6.00 6 5.63 .... 5.87 5.75 7 5.38 .... 5.62 5.50 8 5.13 .... 5.37 5.25 8 4.88 .... 5.12 5.00 9 4.63 .... 4.87 4.75 10 4.38 .... 4.62 4.50 11 4.13 .... 4.37 4.25 11 3.88 .... 4.12 4.00 12 3.63 .... 3.87 3.75 13 3.38 .... 3.62 3.50 13 3.13 .... 3.37 3.25 14 2.88 .... 3.12 3.00 14 2.63 .... 2.87 2.75 15 2.38 .... 2.62 2.50 16 Tab. 6.15 Conversion of RXQUAL to C/I for settings related to AMR HO and PWRC parameters. 1818 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller The C/I delivered by this mapping should be seen as Channel Quality Indicator in the sense of 3GPP 45.009 (section 3.3.1) rather than an estimation of true C/I. 2.13 .... 2.37 2.25 16 1.88 .... 2.12 2.00 17 1.63 .... 1.87 1.75 17 1.38 .... 1.62 1.50 18 1.13 .... 1.37 1.25 18 0.88 .... 1.12 1.00 19 0.63 .... 0.87 0.75 19 0.38 .... 0.62 0.50 19 0.13 .... 0.37 0.25 20 0 .... 0.12 0.00 20 RXQUAL medium RXQUAL calculated C/I Tab. 6.15 Conversion of RXQUAL to C/I for settings related to AMR HO and PWRC parameters. A30808-X3247-L230-3-7619 1819 Commands Base Station Controller CML:BSC Special Parameter Values - Group 7 Group 7 The following Service Groups are identified: SG-1: Signalling on hopping channel SG-2: Signalling on non hopping channel SG-3: CS speech FR - EFR - ASCI VBS - ASCI VGCS on hopping channel SG-4: CS speech FR - EFR - ASCI VBS - ASCI VGCS on non hopping channel SG-5: CS speech HR on hopping channel SG-6: CS speech HR on non hopping channel SG-7: CS data until 9.6 kbit/s or HSCSD 9.6 kbit/s on hopping channel SG-8: CS data until 9.6 kbit/s or HSCSD 9.6 kbit/s on non hopping channel SG-9: CS data until 14.4 kbit/s or HSCSD 14.4 kbit/s on hopping channel SG-10: CS data until 14.4 kbit/s or HSCSD 14.4 kbit/s on non hopping channel SG-11: CS speech AMR - FR on hopping channel SG-12: CS speech AMR - FR on non hopping channel SG-13: CS speech AMR - HR on hopping channel SG-14: CS speech AMR - HR on non hopping channel The following Service Dependent attributes are used to handle Service Groups: SG1HOPAR: sg1HandoverParms SG2HOPAR: sg2HandoverParms SG3HOPAR: sg3HandoverParms SG4HOPAR: sg4HandoverParms SG5HOPAR: sg5HandoverParms SG6HOPAR: sg6HandoverParms SG7HOPAR: sg7HandoverParms SG8HOPAR: sg8HandoverParms SG9HOPAR: sg9HandoverParms SG10HOPAR: sg10HandoverParms SG11HOPAR: sg11HandoverParms SG12HOPAR: sg12HandoverParms SG13HOPAR: sg13HandoverParms SG14HOPAR: sg14HandoverParms SG1PCPAR: sg1PowerControlParms SG2PCPAR: sg2PowerControlParms SG3PCPAR: sg3PowerControlParms SG4PCPAR: sg4PowerControlParms 1820 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller SG5PCPAR: sg5PowerControlParms SG6PCPAR: sg6PowerControlParms SG7PCPAR: sg7PowerControlParms SG8PCPAR: sg8PowerControlParms SG9PCPAR: sg9PowerControlParms SG10PCPAR: sg10PowerControlParms SG11PCPAR: sg11PowerControlParms SG12PCPAR: sg12PowerControlParms SG13PCPAR: sg13PowerControlParms SG14PCPAR: sg14PowerControlParms In order to have a great flexibility in Handover and Power Control algorithmdefinition the operator can differentiate thresholds and flags for Handover and Power Control on service basis using a set of specific attributes. These service dependent values override the service independent attributes shared among services, as shown in the following tables: When the HAND:SGXHOPAR (X = 1..6) is different from NULL, SGXHOPAR fields override the unspecific attributes shared among Service Groups, as shown in the following table: When the HAND:SGXHOPAR (X = 7, 8, 9, 10) is different from NULL, SGXHOPAR fields override the unspecific attributes shared among Service Groups, as shown in the following table: HAND:SGXHOPAR elds Service Independent Attributes hoLowerThresholdLevDL HAND:HOLTHLVDL hoLowerThresholdLevUL HAND:HOLTHLVUL hoThresholdLevDLintra HAND:HOTDLINT hoThresholdLevULintra HAND:HOTULINT hoRxlevDLinner HAND:HORXLVDLI hoRxlevDLouter HAND:HORXLVDLO hoLowerThresholdQualDL HAND:HOLTHQUDL hoLowerThresholdQualUL HAND:HOLTHQUUL Tab. 6.16 Correspondence between service dependent and service independent attributes (SGXHOPAR, X =1..6) A30808-X3247-L230-3-7619 1821 Commands Base Station Controller CML:BSC When the HAND:SGXHOPAR (X = 11, 12) is different from NULL, SGXHOPAR fields override the unspecific attributes shared among Service Groups, as shown in the following table: When the HAND:SGXHOPAR (X = 13, 14) is different from NULL, SGXHOPAR fields override the unspecific attributes shared among Service Groups, as shown in the following table: HAND:SGXHOPAR elds Service Independent Attributes hoLowerThresholdLevDL HAND:HOLTHLVDL hoLowerThresholdLevUL HAND:HOLTHLVUL hoThresholdLevDLintra HAND:HOTDLINT hoThresholdLevULintra HAND:HOTULINT hoRxlevDLinner HAND:HORXLVDLI hoRxlevDLouter HAND:HORXLVDLO hoLowerThresholdQualDL HAND:HOLTHQUDL hoLowerThresholdQualUL HAND:HOLTHQUUL rateHoLowerThresholdQualDL HAND:RHOLTQDL rateHoLowerThresholdQualUL HAND:RHOLTQUL Tab. 6.17 Correspondence between service dependent and service independent attributes (SGXHOPAR, X = 7, 8, 9, 10) HAND:SGXHOPAR elds Service Independent Attributes hoLowerThresholdLevDL HAND:HOLTHLVDL hoLowerThresholdLevUL HAND:HOLTHLVUL hoThresholdLevDLintra HAND:HOTDLINT hoThresholdLevULintra HAND:HOTULINT hoRxlevDLinner HAND:HORXLVDLI hoRxlevDLouter HAND:HORXLVDLO hoLowerThresQualAMRDL HAND:HOLTHQAMRDL hoLowerThresQualAMRUL HAND:HOLTHQAMRUL hoThresAMRComprDL HAND:HOTHAMRCDL hoThresAMRComprUL HAND:HOTHAMRCUL Tab. 6.18 Correspondence between service dependent and service independent attributes (SGXHOPAR, X = 11, 12) 1822 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller When the PWRC:SGXPCPAR (X = 1..10) is different from NULL, SGXPCPAR fields override the unspecific attributes shared among Service Groups, as shown in the following table: When the PWRC:SGXPCPAR (X = 11..14) is different from NULL, SGXPCPAR fields override the unspecific attributes shared among Service Groups, as shown in the following table: HAND:SGXHOPAR elds Service Independent Attributes hoLowerThresholdLevDL HAND:HOLTHLVDL hoLowerThresholdLevUL HAND:HOLTHLVUL hoThresholdLevDLintra HAND:HOTDLINT hoThresholdLevULintra HAND:HOTULINT hoRxlevDLinner HAND:HORXLVDLI hoRxlevDLouter HAND:HORXLVDLO hoLowerThresQualAMRDL HAND:HOLTHQAMRDL hoLowerThresQualAMRUL HAND:HOLTHQAMRUL hoThreshAMRDecomprDL HAND:HOTHAMRDDL hoThreshAMRDecomprUL HAND:HOTHAMRDUL Tab. 6.19 Correspondence between service dependent and service independent attributes (SGXHOPAR, X = 13, 14) PWRC:SGXPCPAR elds Service Independent Attributes EnableBSPowerControl PWRC:EBSPWRC EnableMSPowerControl PWRC:EMSPWRC EnablePowerControlRLFW PWRC:EPWCRLFW PcLowerThresholdLevDL PWRC:LOWTLEVD PcLowerThresholdLevUL PWRC:LOWTLEVU PcUpperThresholdLevDL PWRC:UPTLEVD PcUpperThresholdLevUL PWRC:UPTLEVU PcRLFThreshold PWRC:PCRLFTH PcLowerThresholdQualDL PWRC:LOWTQUAD PcLowerThresholdQualUL PWRC:LOWTQUAU PcUpperThresholdQualDL PWRC:UPTQUAD PcUpperThresholdQualUL PWRC:UPTQUAU Tab. 6.20 Correspondence between service dependent and service independent attributes (SGXPCPAR, X = 1..10) A30808-X3247-L230-3-7619 1823 Commands Base Station Controller CML:BSC PWRC:SGXPCPAR elds Service Independent Attributes EnableBSPowerControl PWRC:EBSPWRC EnableMSPowerControl PWRC:EMSPWRC EnablePowerControlRLFW PWRC:EPWCRLFW PcLowerThresholdLevDL PWRC:LOWTLEVD PcLowerThresholdLevUL PWRC:LOWTLEVU PcUpperThresholdLevDL PWRC:UPTLEVD PcUpperThresholdLevUL PWRC:UPTLEVU PcRLFThreshold PWRC:PCRLFTH PcLowerThresQualAMRDL PWRC:LOWTQUAMRDL PcLowerThresQualAMRUL PWRC:LOWTQUAMRUL PcUpperThresQualAMRDL PWRC:UPTQUAMRDL PcUpperThresQualAMRUL PWRC:UPTQUAMRUL Tab. 6.21 Correspondence between service dependent and service independent attributes (SGXPCPAR, X = 11..14) 1824 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Special Parameter Values - Group 8 Group 8 RADIOMG: radioMeasGran RADIOMR: radioMeasRep Special care has to be applied if the RADIOMR attribute is set at ON for several TRXs, because the measurement result messages increase considerably the LAPD load (increased delay times in the BTSE LAPD queues due to the huge amount of measurement result messages lead to more CHANNEL REQUIRED messages because of a too late IMMEDIATE ASSIGNMENT command, etc.). If only one 64 kbit/s LAPD channel is created in BSC and BTSE, the number of full rate and half rate TRXs for which radio measurements are allowed is limited. Within one BTSM the maximum number of TRXs for which radio measurements are allowed with RADIOMG set at 1 (corresponding to 480 ms) can be evaluated from the following rules and from the table below: i The expression half(full) rate TRXs only means how many TRXs would be covered if the HR(FR) channels were on the same TRXs. The intention is to have a practical and not too detailed result. N_TRX = N_FR_TRX + 2 * N_HR_TRX Max_Meas_TRX = Max_MeasFR_TRX + 2 * Max_MeasHR_TRX Max_MeasFR_TRX = Max_Meas_TRX - 2 * Max_MeasHR_TRX Max_MeasHR_TRX = (Max_Meas_TRX - Max_MeasFR_TRX) / 2 Meaning: N_FR_TRX: Number of full rate TRXs N_HR_TRX: Number of half rate TRXs Max_MeasFR_TRX: Maximum number of full rate TRXs for which RADIOMR may be set at ON value. Max_MeasHR_TRX: Maximum number of half rate TRXs for which RADIOMR may be set at ON value. N_TRX Max_Meas_TRX 1 ... 8 N_TRX 9 ... 11 7 12 ... 15 6 16 ... 18 5 19 ... 21 4 22 ... 24 3 25 ... 28 2 29 1 30 ... 32 0 A30808-X3247-L230-3-7619 1825 Commands Base Station Controller CML:BSC Example: 12 full rate TRXs and 4 half rate TRXs are installed and configured: N_FR_TRX = 12 N_HR_TRX = 4 N_TRX = N_FR_TRX + 2 * N_HR_TRX = 12 + 2 * 4 = 20 From the table Max_Meas_TRX = 4 This means that when the radio measurements are activated for 2 full rate TRXs (Max_MeasFR_TRX = 2), the radio measurements are allowed to be activated for one additional half rate TRX, as Max_MeasHR_TRX = (Max_MeasFR_TRX) / 2 = 1. If two LAPD channels (64 kbit/s each) are created, the values for Max_Meas_TRX are as follows: N_TRX Max_Meas_TRX 1 ... 16 N_TRX 17 ... 22 16 23 ... 35 15 36 ... 48 14 1826 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller Special parameters values - Group 9 Group 9 BCCHFREQTD = bCCHFrequencyTD For the TD-SCDMA mobile system the carrier frequency is designated by a Frequency Band Number field (FBN) and by a Radio Frequency Number field (RFqN) within the band. The carrier spacing is 1.6 MHz, while the carrier raster is 200 KHz. The value part of a Frequency Band information element is coded as shown in Tab. 6.22. Band FBN Lower Band RFqN F range [MHz] Secondary 0000 (0) F(RFqN)=1785.8+0.2* (RFqN) 0<= RFqN <=92 1785.8-1804.2 Extended 1 0001 (1) F(RFqN)=1900.8+0.2* (RFqN) 0<= RFqN <= 92 1900.8-1919.2 Extended 2 (Part A) 0010 (2) F(RFqN)=1920.8+0.2* (RFqN) 0<= RFqN <=255 1920.8-1979.2 (Part B) 0011 (3) F(RFqN)=1971.8+0.2* (RFqN+1) 0<= RFqN <=36 Extended 3 0100 (4) F(RFqN)=1980.8+0.2* (RFqN) 0<= RFqN <=142 1980.8-2009.2 Primary 0101 (5) F(RFqN)=2010.8+0.2* (RFqN) 0<= RFqN <=67 2010.8-2024.2 Extended 4 (Part A) 0110 (6) F(RFqN)=2110.8+0.2* (RFqN) 0<= RFqN <=255 2110.8-2169.2 (Part B) 0111 (7) F(RFqN)=2161.8+0.2* (RFqN+1) 0<= RFqN <=36 Extended 5 1000 (8) F(RFqN)=2170.8+0.2* (RFqN) 0<= RFqN <=242 2170.8-2219.2 Tab. 6.22 Occupation of the Frequency Bands for the TD-SCDMA A30808-X3247-L230-3-7619 1827 Commands Base Station Controller CML:BSC Special parameters values - Group 10 Group 10 Handover thresholds: HOLTHQUDLTD: hoLowerThresholdQualDL (range: 1..63) HOLTHQUULTD: hoLowerThresholdQualUL (range: 1..63) Threshold Signal Quality Range for Bit Error Rate 01 Log 10 (Channel BER) < -4.030 02 -4.030 < Log 10 (Channel BER) < -3.965 03 -3.965 < Log 10 (Channel BER) < -3.900 .... -3.900 < Log 10 (Channel BER) < .... < Log 10 (Channel BER) < -0.195 61 -0.195 < Log 10 (Channel BER) < -0.130 62 -0.130 < Log 10 (Channel BER) < -0.065 63 -0.065 < Log 10 (Channel BER) <= 0.000 Tab. 6.23 Relationship between Signal Quality and BER 1828 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller A30808-X3247-L230-3-7619 1829 Commands Base Station Controller CML:BSC 7 Abbreviations LMT Local Maintenance Terminal 1830 A30808-X3247-L230-3-7619 CML:BSC Commands Base Station Controller
Predictive Maintenance Attempts To Detect The Onset of A Degradation Mechanism With The Goal of Correcting That Degradation Prior To Signiicant Deterioration in The Component or Equipment