This phenomenon is not discussed further in this paper; it suffices to say that, in such cases,
eliminating the excessive vibrations is the only practical solution.
The following sections address the aerodynamic noise generation in valves and
demonstrate that it can be reduced by controlling the characteristics of turbulence in the flow
path. Control valves that are selected and designed to follow the criteria for fluid kinetic energy
leaving the valve trim as outlined by Miller
1
are less likely to have noise problems than those
that do not follow this guideline. This provides the designers a first screen in the design process.
This approach is dependable, easy-to-understand and verifiable for the stand-point of the end-
users. As a result, it empowers practicing engineers to make good selection of control valves
without getting smoked by the details of noise prediction, which is a complex subject.
A. ISA Guidelines for Control Valves
There is no industry standard as far as how best to achieve pressure reduction in valves. However,
the guidelines in Table 1 serve as good screening criteria, especially for severe service valve
applications, and have been recommended for practice
1
. Several well documented analysis of
practical experiences have demonstrated that limiting fluid kinetic energy (rV
2
/2) exiting the
valve trim is a key requirement in assuring good performance in severe service applications
2 3
.
Table 1: Trim Outlet Kinetic Energy Criteria
1
Service Conditions Kinetic Energy
Criteria
Equivalent Water
Velocity
psi kPa ft/s m/s
Continuous Service, Single-
phase Fluids
70 480 100 30
Cavitating and Multi-phase
Fluid Outlet
40 275 75 23
Vibration-sensitive System 11 75 40 12
This unified criterion addresses several problems that are chronic in high fluid energy
applications; it is simple to understand, easily specified and verifiable. Most of all, it maintains
the key essence of the physics of the phenomena being addressed in the selection and design
process
4
.
2. NOISE GENERATED BY FLOW
Turbulence in the flow is a primary source of noise in the case of valves and piping systems. The
nature of turbulence varies in different flow; hence, the characteristics of noise generated by
different sources also vary accordingly. In this context, the flows can be broadly categorized as:
(1) jets, and, (2) flows with no separation, or with a closed separation bubble.
The major difference between these two categories is the nature of the shear flow
development downstream. The nature of turbulence varies in each case. Typical values of
turbulence intensity, which is the ratio of the turbulent velocity of the fluid to its mean flow
velocity, and length scales vary widely. The turbulence intensity for jets in about 25% to 30%,
while it is only 5% to 8% for fully developed turbulent pipe flows (flow with no separation).
The large length scales in jet flows are of the order of the jet diameter; for pipe flows, the length
scales are of the order of the pipe diameter. Such marked differences have significant impact on
noise generation.
Jets may be confined or unconfined (free). From the stand-point of noise generation, they
are considered to be very similar. The turbulence level in the shear layers of jets is high and is a
primary source of noise. Flows separated from the wall behave similar to jets as far as noise
production.
In the same manner, the action in a closed separation bubble is very local and its impact on
noise generation can be neglected, i.e. it may be treated like flow with no separation.
At times, resonance in the system is the source of high noise; however, that is not the focus of
the discussion here.
A. Basic Features of Valve Construction and Resulting Flow Path
Typical construction of globe style, linear control valves is illustrated in Figure 1. These valves
can be constructed with different configurations of trims, some of which are shown in Figure 2.
Predominant noise source is aerodynamic fluid jet(s) exiting the throttling point in the valve trim.
Figure 1: Basic construction of a linear sliding stem globe valve
Figure 2: Different trim types used in control valves; A
t
denotes throttling areas that create jets.
The multi-stage trim forms of the type shown in Figure 3 were specially developed for
severe service applications; in such designs, the total pressure drop is broken down into many
stages. This causes pressure drop across individual stages to be much smaller; most importantly,
pressure drop across the last stage, which is the key for noise generation, can be controlled
through design.
Figure 3: Multi-stage, multi-path trim for severe service applications
Some valve manufacturers use orifice plates and/or pressure-reducing diffusers to limit the
pressure drop across the trim. They are placed downstream of the valve throttling element and
force the flow through many small jets. So, taking a significant pressure drop is a primary
function of such elements.
Flow distributors, when used, are located in the regions of abrupt area transitions
downstream of the valve throttling element. Their primary function is to avoid large jets, or flow
separation, that would otherwise take place in the flow path. Pressure drop associated with flow
distributors is generally small, and incidental this feature differentiates flow distributors from
orifice plates and pressure-reducing diffusers. A typical geometry of a flow distributor is shown
in Figure 4.
B. Noise Generating Flow Features in Valves and Associated Piping
The noise generation takes place within the physical envelope of the valve and also in the piping
systems. The flow characteristics of major sources that cause noise generation are described
below.
Valve trim Predominant noise source is aerodynamic fluid jet(s) exiting the throttling
point in the valve trim. High speed fluid jet(s) at the trim exit are in place by design for the
purpose of the pressure reduction process; the resulting noise may be described as collateral
damage. The turbulence and noise generation characteristics of this source are modeled after jet
theory.
Figure 4: Typical geometry of a flow distributor.
.
Transitions at valve-piping joints Another predominant noise source may be expansion
noise caused by the flow exiting the valve outlet into much larger outlet piping (as illustrated in
Figure 5). It is a problem only when flow separates from the pipe wall to form a jet and the fluid
energy is high. Valve sizes are often not the same size as the pipe lines in which they are located.
Severe service control valves take a significant percentage of the system pressure drop. As a
result, they often have reduced-size trims or are smaller in size than the surrounding pipes. The
transition at the valve inlet is rarely a problem since the area is decreasing and tendency for flow
separation is suppressed. On the other hand, a number of factors are at play at the valve outlet.
One, the density is lower at the valve outlet (compared to the inlet) so the velocities, and by
extension the kinetic energy, are higher at the valve outlet. Also, any area increase in the
transition from valve outlet to the line size has high potential for flow separation. The net result
is that the turbulence intensity in this region can be high and, if uncontrolled, can be a major
source of high noise.
n
a
M E K W . (2)
This form illustrates the huge importance of fluid kinetic energy in noise generation in
valves. The fluid kinetic energy term appears explicitly in noise generation equations. In
addition, it is related to the Mach number for given conditions of local pressure and temperature.
Lower kinetic energy means lower Mach number. As a result, lowering of fluid kinetic energy
has a multiplier effect on noise reduction. When these relationships are applied to the jet(s)
exiting the valve trim, the benefit of controlling kinetic energy at the trim exit is evident.
The close relationship between noise power and the jet kinetic energy is also evident in
Figure 6
4
. It shows the measurements made for a 3 mm diameter jet issuing into ambient air for
isentropic Mach numbers of up to 2. Also shown in this plot are predictions based on standard
equations for jet noise.
Figure 6: Sound power and the kinetic energy at the exit for a jet issuing into ambient
4
.
Noise produced by other (non-jet) types of flows - The noise produced by flows that remain
attached to the boundary walls is proportional to the pressure drop in approximate terms. Since
pressure drop is proportional to fluid kinetic energy, the noise thus produced is also proportional
to fluid kinetic energy.
Disturbances in the flow path add to noise. Disturbances in piping systems may be caused
by abrupt changes in fluid path. The effect of fittings and obstructions in these flows is similar.
They result in strong secondary motion and/or increased turbulence and mixing, which become
additional sources of noise. The increase in noise due to these effects has also been shown to be
roughly proportional to the pressure drop, and hence to fluid kinetic energy.
3. APPLICATION TO CONTROL VALVE DESIGN AND SELECTION
It is evident that the primary noise sources in valves are from jets flows exiting the trim and, in
some cases, the jet from the valve outlet. From the basic noise equations for predicting noise, it is
possible to derive the effect of trim exit kinetic energy on valve noise generation.
Trim noise Equation (2) can be written in the form below to compare the difference in
noise power from two different types of valve trims:
( ) | | ( ) ( ) ( ) ( ) | |
1 1 2 2 1 2
log 2 log 2 10 . . . . log 10 dB M n M n E K E K W
a
+ = A . (3)
Subscripts 1 and 2 in the equation above refer to the two trims being compared. The first term in
this equation may be considered as the effect of different fluid kinetic energy levels. The trim
exit jet Mach numbers, M
1
and M
2
, in the second term are also related the respective fluid kinetic
energies K.E.
1
and K.E.
2
. The variation of second term with fluid kinetic energy depends on the
outlet pressure and is a bit complex; however, its contribution is in the same direction as the first
term.
Calculations were made for a high pressure, steam turbine bypass valve which reduces
pressure from 18 MPa to 4 MPa. A conventional valve in such service would be very noisy and
selection of sufficient number of pressure reducing stages in the trim is important to keeping
noise low. Figure 7 illustrates the dependence of noise on trim exit kinetic energy; using 1030
kPa as a reference, this plot shows the increase in noise as the trim exit kinetic energy increases.
Figure 7: Dependence of trim exit kinetic energy on noise for a high pressure turbine bypass application.
Figure 7 illustrates that limiting trim exit kinetic energy to 1030 kPa will always result in a
quieter valve when compared to a design where this parameter exceeds that value. In general,
the effect of trim exit kinetic energy on noise generation becomes increasingly significant as the
valve outlet valve outlet pressure gets higher. For a the range of control valve designs seen in
high pressure (HP) turbine bypass (TB) to cold reheat service, Figure 7 suggests that the
difference in noise generation can be over 15 dB between a conventional valve and one in which
a 1030 kPa limit is set on the fluid kinetic energy exiting the valve trim.
Fluid kinetic energy is a controllable parameter in valve design which strongly influences
noise generation. Therefore, it becomes an easy, and useful, screening criterion in selection of
valves for users. An estimate of expected difference in noise for different design options based
on Figure 7, or on Equation 3, is useful in comparing various design options. Although such a
check is approximate, it is: (a) independent of suppliers biases, and, (b) does not require detailed
noise calculations.
A limit on trim exit kinetic energy is intended as a screening criterion only not as the only,
and an absolute, criterion. Good engineering practices and standards must be followed as well.
Valve outlet jet noise It is a significant noise source from two different perspectives. First,
the jet noise adds to the noise from other sources in the valve thereby increasing the overall noise
power. Second, the jet noise is distributed in low frequency regions because of the large diameter
of the jet; low frequency components attenuate less through the pipe walls and also have lowered
benefit of A-weighting as far as the noise propagated to the outside. In addition, high energy
valve outlet jets have a potential to cause serious vibration in the system. As a result, a high
energy jet at the valve outlet is undesirable. Flow distributor is preferred over high pressure drop
devices (for e.g., orifice plates, flow diffuser, pressure-reducing cylinders etc) to avoid any
significant additional noise generation.
Piping noise Noise produced by high speed flow in piping, and through fittings such as
elbows, tees etc, is often a concern. It is often addressed by limiting the Mach number of the
flow in the pipe. However, these noise sources are also strongly dependant on fluid kinetic
energy, and in the similar way as the trim noise. As a result, a limit on the fluid kinetic energy in
the piping makes a superior criterion for pipe size rather than just the Mach number.
For low pressure, pipe selection based on a fluid kinetic energy limit has successfully
resulted in the selection of smaller pipe sizes than that based only on a conservative Mach
number limit. Therefore, it is recommended as a design criterion in the selection of pipe size.
4. CONCLUSIONS
Fluid kinetic energy at the trim exit is closely related to valve noise generation. Noise
requirements are more likely to be met when ISA Guidelines for trim exit kinetic energy are
followed than otherwise.
The recommended fluid kinetic energy exiting the trim for intermittent service, high
pressure turbine bypass valves is 1030 kPa. Following these guidelines results in noise levels that
are over 15 dB less when compared to conventional single-stage pressure drop designs.
The high energy jet from the valve outlet into a much larger piping should be avoided. It is
a source of high noise generation. To eliminate this large, low frequency jet, flow distributors are
preferred over orifice-plates, or pressure-reducing diffusers which are themselves a source of
noise.
REFERENCES
1
Herbert L. Miller, Control Valve Applications, Chap.12, Pgs 434-438, in Control Valves Practical Guides for
Measurement and Control, edited by Guy Borden, Jr. and Paul G Friedmann (Instrument Society of America,
North Carolina, 1998).
2
Herbert L. Miller and Laurence R. Stratton, Kinetic Energy as a Selection Criteria for Control Valves, ASME
Fluids Engineering Division, Summer Meeting, Paper FEDSM97-3464, Vancouver, B.C., Canada, June 22-26,
1997.
3
Herbert L. Miller, Laurence R. Stratton, and Mark A. Hollerbach, The Case for a Kinetic Energy Criterion in
Control Valves Part 1, ISA EXPO 2005, Paper ISA 2005-P133, The Instrument, Systems and Automation
Society, Research Triangle Park, North Carolina, Chicago, October 25-27, 2005.
4
Sanjay V. Sherikar and Vinay K. Nagpal, Fluid Kinetic Energy Based Limits in the Design of Control Valves and
Valve-Related Systems, 5TH ASME/JSME Joint Fluids Engineering Conference, Paper FEDSM 2007-
37690,San Diego, CA, USA, July 30-August 2, 2007.
5
Noise considerations Control Valve Aerodynamic Noise Prediction Method, Part 8-3, IEC Standard 60534-8-3,
Second Edition, International Electrotechnical Commission, Geneva, Switzerland (2000)
6
Barry N. Taylor, Guide for the Use of the International System of Units (SI), NIST Special Publication 811,