Вы находитесь на странице: 1из 1

Location Plan: Not To Scale

+425
+1105
+1275
+0
HOF-01-10: HEROES OF FIRE - SECTION AA THROUGH AUDITORIUM
Event Communications Ltd
India House, 45 Curlew Street
London SE1 2ND
Telephone +44 (020) 7378 9900
Fax +44 (020) 7378 9911
email info@eventcomm.com
original scale : 100mm This drawing may have been reduced
100 0
Reference Drawings Legend Notes
Drawing number
A
p
p
ro
v
e
d
Approved
Date
Revision Project number
Scale
Date
Drawn
Title
Date
Checked
Project
D
a
te
C
h
e
c
k
e
d
D
ra
w
n Description
Revisions
R
e
v
is
io
n
(when plotted @A1)
EA / 1703
KUWAIT OIL CO.
K. S. C.
NEW DISPLAY CENTRE
AHMADI, KUWAIT
SDA - HOF-01-10
18.07.08
DS
1:25
SECTION AA THROUGH AUDITORIUM
HEROES OF FIRE
issue for tender B2
B2
'lean seating' made of
tubular stainless
steel for approximately
50 people. See specification
EX05720 Ornamental Hand Rails
and Guard Rails
Curving setwork barrier,
with angled top-lip to
prevent visitors seeing
re effect equipment in
the pit below
Faux ame steam
effect unit, mounted
onto individual
stands. All units link
to central drainage
channel
Propane ame shooter, mounted
to a low level stand which xes
directly into slab oor
3no. soft edged projections on
curved wall of theatre - combines to
create one overall wide panoramic
view.
Heroes of Fire
perimeter
enclosure forms part
of base build package
Handrail
with
low-level
inll at
1100mm
Tiered and radiused
auditorium floor levels
at 6no. 170mm depth
increments, beginning at
1275mm. Floor surface
clad with steel
treadplate.
Area to rear of
auditorium designated
for wheelchair viewers
3149
3410
4
3
1
8
C
le
a
r
v
ie
w
in
g
a
r
e
a
Handrail at
1100mm
xed to
radiused wall
Propane ame
Faux ame
FROM CENTRUM
Steam supply
pipe and
drainage
channel xed
to rear side
of setwork
barrier
SAFETY ZONE
Radiused fireproof canopy
high-temperature boarding to
capture steam and gas jet
exhaust from below - Provided
as part of basebuild package.
Nitrogen cannon suspended from
ceiling rig. Cannon rotates to
extreme points of projection area.
Drip tray suspended beneath front
nozzle to drain excess liquid into
HOF general drain
Circular array of 3no. projectors,
xed to steel supports under the
overhead suspended access gantry
Projector access gantry that spans
the entire theater. Gantry supports
the projectors / nitrogen fog cannon
and lighting for the theatre.
Balustrade set at 1100mm with the
lower rail set @ 300 off the gantry
oor to allow space for lights to
move during show.
Direct lighting for nitrogen cannon
suspended from front of projector
access gantry
Access door to effects
pit and high-level
projection gantry
Wall within exhibition
package.
NOTE: DRAWING TO BE READ IN CONJUNCTION WITH:
HOF-01-01 GENERAL ARRANGEMENT
HOF-01-03SPECIAL EFFECTS GENERAL LAYOUT
HOF-01-04 HVAC INTERGRATION OVERLAY
HOF-01-05 SCREEN & PROJECTION GANTRY
HOF-01-08 STAGE & UPSTAND PLAN (SHOWING UNDERFLOOR ACCESS)
HOF-01-09 SECTION A-A THROUGH AUDITORIUM WITH HVAC OVERLAY
HOF-01-10 SECTION THROUGH AUDITORIUM ONLY
HOF-01-11 EXTENDED ELEVATIONS
HOF-01-13 HIGH LEVEL PROJECTOR / EFFECTS / LIGHTING GANTRY
HOF-01-14 FOG CANON DRIP TRAYS
HOF-01-15 THEATRE LEAN BARS & DETAILS
HOF-01-16 MECHANICAL RISING PLASMA SCREEN LIFT DETAILS
HOF-01-17 THEATRE ZONE PLAN
HOF-01-18 BGB CONTROL UNIT
HOF-01-19 PROPANE / CRYO SUPPLY ROUTES
DO NOT SCALE FROM THIS DRAWING
THIS DRAWING IS SET UP AT A1 SIZE
THIS DRAWING IS TO BE READ IN CONJUNCTION
WITH THE THE FOLLOWING SPECIFICATION NUMBERS:
EX100 SETWORKS
EX120 SPECIAL EFFECTS
EX125 SHOW EFFECTS CONTROL PANEL
EX150 MODEL MAKING
EX200 GRAPHIC PRODUCTION
EX300 AV/IT HARDWARE
EX500 EXHIBITION LIGHTING
EX900 SPARE COMPONENTS
EX05720 ORNAMENTAL HANDRAILS AND GUARDRAILS
30.09.08
CC
15.05.09
CC
15.05.09
D
S
/G
B
C
C
C
C
+9350
+765
+595
TOP LINE OF PROJECTION BEAM.
BASE LINE OF PROJECTION BEAM
.
'SC' denotes circular array of 5no.
plasma screens in landscape
orientation. Screens are mounted to
individual rising mechanical arms
bolted to the oor of the re pit to
raise and lower into the visitors line of
view. This is a Contractor design item.
General arrangement shop drawings
and component references to be
submitted to the Superintendent prior
to fabrication. See drawing
HOF-01-16 for details.
Dotted perimeter lines indicate extent
of arm when hidden and needs to be
totally free of equipment and/or
pipework
Line of fire canopy.

Вам также может понравиться