Accreditation Number : LK-064-IDN


Address : Jl. Jendal Ahmad Yani No.245, lt III, Bandung
Telephone : 022-7234688
Facsimile : 022-7234688
Contact Person : Miftachul Huda; Suyitno
Temperature
No. Instrument to be calibrated Methods/Specifications Notes
1 Liquid in glass thermometer 0 C ~ 150 C 0.25 C ASTM E77: 1998
2 Temperture sensor with display unit 0 C ~ 150 C 0.25 C BS 5235: 1992
150 C ~ 400 C 0.8 C OIML D 11: 1994
400 C ~ 1000 C 1.8 C
3
Temperature indicator without sensor
(for thermocouple sensor)
-200 C ~ 2000 C 0.2 C
ASTM E 230: 2002;
ASTM E1137: 2002;
EA 10/11: 2000
4 Thermometer Resistance Sensor 0 C ~ 150 C 0.25 C ASTM E 644: 2002
150 C ~ 400 C 0.5 C ASTM E 1137: 2002
400 C ~ 1000 C 1 C
5 Thermocouple Sensor (K,J,R,S,T) 0 C 1000 C 2.5 C
ASTM E220: 2002;
ASTM E230: 2002;
ASTM E608: 2000;
EAL G31: 1997
6 Temperature enclosure
(incubator, autoclave, bath, oven, 0 C ~ 400 C 1.3 C
AS 2853: 1986
furnace) 400 C ~ 1000 C 2.5 C
Mass
No. Instrument to be calibrated Methods/Specifications Notes
2 Balance 0 g ~ 100 g 0.26 mg
The Calibration of Balance
(electronic; mechanic) 100 g ~ 200 g 0.52 mg
NML-CSIRO: 1995
200 g ~ 600 g 1.4 mg
600 g ~ 1200 g 2.5 mg
1200 g ~ 2100 g 4.4 mg
2100 g ~ 3000 g 8.5 mg
3000 g 5000 g 10 mg
5000 g ~ 10000 g 75 mg
Pressure
No. Instrument to be calibrated Methods/Specifications Notes
1 Pressure gauge; 0 psi ~ 60 psi 1.2 psi BS EN 837-1: 1998
Pressure recorder; 0 psi ~ 150 psi 1.6 psi EA 10/17: 2002
Pressure Transducer 0 psi ~ 800 psi 4.7 psi
PT. INDOCAL LABORATORI SISTEM
Measurement Range
Best Measurement
Capability *)
Measurement Range
Best Measurement
Capability *)
(1 psi = 6894,76 Pa)
Measurement Range
Best Measurement
Capability *)
1 of 2
Force LK-064-IDN
No. Instrument to be calibrated Methods/Specifications Notes
1 Force Testing Machine 0 kgf ~ 50000 kgf 36 kgf
(Tension/Compression) 0 kN ~ 60 kN 0.33 kN BS EN 1610 part 1-2: 92
60 kN ~ 1000 kN 2.8 kN BS EN 10002-2 : 1992
1000 kN ~ 2000 kN 3.4 kN EAL G-22: 1996
Notes:
Best Measurement Capability is stated as Expanded Uncertainty at approximately 95% confidence level, calculated using
coverage factor of k = 2, includes uncertainty contribution due to reference standards used by the laboratory, measurement process
at the laboratory, and contribution due to typical characteristic of nearly ideal device under calibration respective to the laboratory
The actual characteristic of device under calibration shall also be considered for individual calibration certificate issued
by the laboratory
( 1 kgf = 9,80665

N)
Measurement Range
Best Measurement
Capability *)
2 of 2