Вы находитесь на странице: 1из 21

1 | P a g e

2013 Geo Products, LLC



























Design and Installation Guidelines
for Retaining Walls

Geo Products, LLC
8615 Golden Spike Lane
Houston, TX 77086
Phone: 281.820.5493
Fax: 281.820.5499
www.geoproducts.org

2 | P a g e
2013 Geo Products, LLC


Design Considerations 6-10
Economics & Aesthetics 11
Environmental Merit 12-15
Installation 16-21
Mechanics of Retaining Walls 3-4
The EnviroGrid Solution 5
3 | P a g e
2013 Geo Products, LLC







Mechanics of Retaining Walls
The growing scarcity of land that is affordable and easy to build upon is causing engineers,
contractors, and developers to find innovative ways to use less desirable parcels of land. Areas
with rough terrain and/or steep slopes were once considered as being unusable for
development. Many of these areas can be made virtually flat, and thereby usable, through the
employment of structures such as retaining walls and steepened slopes.
The two basic types of retaining walls are cantilever
and gravity. Most cantilever retaining walls are
made of cast-in-place, steel-reinforced concrete.
This type of structure is able to retain the earth
behind it by virtue of its internal strength and
rigidity. Reinforced concrete retaining walls are
expensive to build, cannot be built in very cold
weather, and are not especially attractive. These
walls are brittle, and if stresses resulting from
differential settlement exceed the strength of the
concrete, cracks develop affecting the structures
stability and appearance.
Gravity retaining walls are constructed principally of soil
that is stabilized with man-made materials such as
EnviroGrid. This type of structure is able to retain the
earth behind it by virtue of its weight. Gravity retaining
walls are typically inexpensive to build and can be built in
nearly all weather conditions. In addition, they have a
degree of flexibility that allows them to adjust to small
amounts of differential settlement without suffering
structural damage.

4 | P a g e
2013 Geo Products, LLC


EnviroGrid can also be used to create a steepened
slope. Steepened slopes are slopes which are
constructed much steeper than the soil alone would
allow. A steepened slope made with EnviroGrid can be
considered to be a retaining wall with a face inclination
greater than 70














5 | P a g e
2013 Geo Products, LLC




The EnviroGrid Solution

An EnviroGrid retaining wall or steepened slope can be constructed in almost any situation
where a rapid change of grade is desired. EnviroGrid confines the soil or other fill material
allowing the material to behave as a reinforced mass.

EnviroGrid can be used in both fill and cut applications. In a
project where the structure is built with fill material, it is
usually more cost-effective to use EnviroGrid in conjunction
with a geogrid. The geogrid acts as a tieback in the reinforced
zone. EnviroGrid assumes the role of the facing element, such
as concrete blocks in a modular block retaining wall. Unlike
modular block, EnviroGrid is easy to handle, flexible, and can
be planted with grass or shrubbery to give the face a natural
look.

In cut situations, the exposed face is unstable because the soil
holding it in place has been removed. Some of this weight
needs to be replaced but in a much smaller area. In this
circumstance it is often more economical to use EnviroGrid in
lieu of other methods such as gabion baskets. When used in
this manner, the stack of filled EnviroGrid panels acts as a
near vertical, heavy, reinforced mass
6 | P a g e
2013 Geo Products, LLC
Design Considerations
A gravity retaining wall must have sufficient weight and width or be otherwise supported so
that it does not overturn or slide forward due to external forces being exerted upon it. The wall
must also be able to hold together as a unit in order to function. That is, the wall must be stable
with respect to both the external forces that might cause it to fall and the internal forces that
might cause it to lose its shape and/or deformed
External Stability
EnviroGrid retaining walls must be designed to be stable with respect to four potential
external failure modes: global stability, base sliding, overturning, and bearing capacity.





GLOBAL STABILITY refers to the stability of the wall,
the soil behind it, and the soil below it. The design
engineer must be certain that the entire area
including the wall does not collapse. A thorough soil
analysis must be performed to eliminate the
possibility of global failure.










7 | P a g e
2013 Geo Products, LLC







BASE SLIDING refers to the outward movement of
the bottom of the retaining wall as a result of the
lateral forces generated by earth pressure and, if
present, water pressure. The force resisting base
sliding is the friction between the fill in the bottom
layer of EnviroGrid and the foundation soil beneath
the bottom layer. The designer may increase the
front-to-back dimension of the wall if calculations
show that the resisting force is less than required.
This will increase the area available to develop the
resisting force. A second option would be to use a fill
with greater frictional characteristics.

OVERTURNING refers to the tipping over of the
retaining wall as it rotates about the toe of the
structure. The overturning force is the sum of
each destabilizing force times its moment arm.
The stabilizing force, or righting moment, is the
product of the weight of the retaining wall and
its moment arm, which is the horizontal distance
from the toe to the center of gravity of the wall.
If calculations show that the righting moment is
less than required, one option is to increase the
front-to-back dimension of the wall, thereby
increasing its overall weight and the magnitude
of its moment arm.
8 | P a g e
2013 Geo Products, LLC

BEARING CAPACITY refers to the ability of the
foundation soil to support the weight of the
retaining wall placed upon it. The analysis is
the same as for shallow foundations. It is
necessary to increase the area of the base if
calculations show that the soil beneath the
wall is too weak. This will decrease the
pressure (force per unit of area) on the
foundation. Another option is to increase the
depth into the ground of the retaining wall,
thus increasing the ability of the foundation
soil to resist the imposed weight.

For each of these considerations, the resisting or stabilizing forces must exceed the forces that
would cause failure by a predetermined factor of safety for each of these considerations. The
selected factors of safety should reflect the consequences of failure and the designers
confidence in the accuracy of the input parameters. The following factors of safety are normally
used in the design of gravity retaining walls:

Global Stability FS
gl
= 1.3
Base Sliding FS
sl
= 1.5
Overturning FS
ot
= 2.0
Bearing Capacity FS
bc
= 2.0

If the minimum front-to-back dimension of a wall that uses
EnviroGrid is at least 0.6 times the wall height, the above
factors of safety will be achieved in almost any design.
9 | P a g e
2013 Geo Products, LLC








Internal Stability
Internal stability refers to the ability of the individual parts of the wall to act as a single unit.
The wall must be designed so that the individual pieces of the wall do not pullout, separate, or
slide apart. In a modular block wall, the designer must be concerned with the potential of the
tieback failing under tension or pulling out from the soil or the fascia. Also, a failure can occur if
the fascia bulges out. The only internal stability consideration for walls consisting of
EnviroGrid and soil is the potential for sliding between panels. If a factor of safety of 1.5 or
greater is not achieved with the initial design, the sections need to be made longer to increase
the surface area or change the fill material to one with greater frictional characteristics.




10 | P a g e
2013 Geo Products, LLC





















NOTE: For detailed design guidelines for retaining walls using EnviroGrid, please contact your
local EnviroGrid distributor or Geo Products, LLC. The final design of any retaining wall must be
developed by an engineer registered in the state where the project is located.

Typical Design
11 | P a g e
2013 Geo Products, LLC
Economics
In many projects such as highway widening, rapid changes in grade are a necessity. In other
projects such as apartment complexes on a steep slope, a rapid change in grade is the most
efficient means of putting the available land area to economic use. A cost effective way to
achieve a rapid change in grade is to construct a reinforced earth gravity wall or slope.
EnviroGrid, by itself or in combination with a geogrid, can be as effective as more expensive
alternatives such as cast-in-place, steel-reinforced concrete retaining walls, modular block
walls, or gabion baskets. EnviroGrid is lightweight, easy to handle, can be filled with on-site
materials, and does not require any special equipment for installation.


Filling and Cutting to Put Available Land Areas to Economical Use

Aesthetics
The outer cells of an EnviroGrid panel are available in non-perforated black, tan, or green cells
that can be filled with topsoil and planted with grass, shrubs, or flowers. A vegetated
EnviroGrid wall or steepened slope can give a look that blends in with the local surroundings,
adds color to the area, and softens the appearance of the wall face.
In addition, a vegetated wall will absorb much of the volume and force of any water that flows
down the slope. This can have a significant impact on the potential consequences of a large
quantity of water pouring down a steep wall face.

12 | P a g e
2013 Geo Products, LLC
Environmental Merit

The EnviroGrid geocell is designed and implemented in order to maximize environmental
benefit. Geo Products recognizes that construction generally leaves a significant footprint upon
the environment, and therefore seeks to reduce any impact that our EnviroGrid incurs upon
the landscape. The limited amount of infill required for EnviroGrid as opposed to conventional
construction methods, as well as the lower quality needed, offers not only a much softened
blow to the environment but also reduces project engineering, length, and cost.
In addition to a significantly lower construction and carbon footprint upon the environment,
EnviroGrid acts as a green building practice in diminishing erosion along slopes and
embankments. The vegetative cover encouraged by EnviroGrid is another source of soil
stabilization as well as aesthetic value more difficult to achieve with conventional
construction.

As an innovative method to facilitate green thinking, EnviroGrid is an effective solution to
protect and preserve the environment when such a mindset is growing ever more desirable.
LEED Green Building Credits

The Leadership in Energy and Environmental Design (LEED) system for designing and certifying
environmentally sustainable buildings is the national standard for rating environmentally
responsible construction. Introduced and enabled by the United States Green Building Council,
LEED takes into account materials and resources used, site location and development, air
quality, and water and energy use in its evaluation of green buildings.

Geo Products' EnviroGrid cellular confinement system is designed and implemented with
environmental merit as a top priority, and contributes heavily to a higher LEED rating for your
green building project. Please refer to the US Green Building Council Website for further details
on the LEED certification system at www.usgbc.com.

LEED Sustainable Site Credit 5.1: Site Development--Protect or Restore Habitat

Requirements:
For Greenfield sites--sites not previously developed and remain in a natural state--limit all site
disturbance to the specified parameters. For previously developed areas, restore or protect a
specified area of the site with acceptable vegetation.


13 | P a g e
2013 Geo Products, LLC
Geo Products Solution and LEED Credit Opportunities:
EnviroGrid provides options for pervious paving in parking and access road functions, thus
reducing disruption to existing ecosystems and minimizing the construction footprint. Also,
through the stabilization of steepened slopes and of storm water detention facilities, EnviroGrid
is able to reduce the construction footprint and keep site disturbance within the necessary
parameters.
For previously developed building areas, use of the EnviroGrid geocell allows for the restoration
or promotion of vegetation, thus contributing to the ecosystem and further minimizing site
disturbance.
The retaining wall and slope stabilization features of EnviroGrid reduce valuable land
consumption in an environmentally-friendly fashion.
LEED Sustainable Site Credit 5.2: Site Development--Maximize Open Space

Requirements:
To provide acceptable, vegetated open space within the project boundary in accordance with
specified parameters, and to reduce development footprint.

Geo Products Solution and LEED Credit Opportunities:
EnviroGrid is ideal for encouraging useful vegetated open space whether with green parking
areas through load support functions or by reducing land consumption with environmentally
friendly slope stabilization and earth retention purposes. In any application, EnviroGrid is
designed to provide the most open space by eliminating the need for further drainage facilities
or by allowing for steeper slopes with minimized environmental damage.
LEED Sustainable Site Credit 6.1 and 6.2: Stormwater Design--Quantity and
Quality Control

Requirements:
Implement a stormwater management plan to limit disruption of the ecosystem by limiting the
area of impervious cover and increasing the area's drainage capability according to specified
guidelines. Also, to reduce the pollution and erosion associated with stormwater runoff.

Geo Products Solution and LEED Credit Opportunities:
EnviroGrid is designed to ensure natural water flows--porous pavement, earth retention, and
slope stabilization applications all allow stormwater to drain in an environmentally responsible
manner. Use of EnviroGrid reduces the use of impervious cover and impervious concrete
retention walls, thereby reducing pollutant loadings. EnviroGrid is also useful in creating
natural treatment systems of stormwater runoff.
14 | P a g e
2013 Geo Products, LLC


LEED Sustainable Site Credit 7.1: Heat Island Effect--Nonroof

Requirements:
To reduce the heat island impact on microclimates and surrounding habitat, measures must be
taken to reduce the heat absorption of exterior materials.

Geo Products Solution and LEED Credit Opportunities:
US Green Builders Council suggests the use of vegetated or permeable surfaces such as
EnviroGrid instead of constructed hardscape, thereby reducing the area's tendency to absorb
heat significantly. The promotion of vegetative cover also contributes to the overall reduction
of heat island effects.

















15 | P a g e
2013 Geo Products, LLC
LEED Materials & Resources Credit 5.1 and 5.2: Regional Materials

Requirements:
To reduce the environmental impact resulting from transportation of construction materials by
using materials and products that are extracted and manufactured within the region.

Geo Products Solution and LEED Credit Opportunities:
EnviroGrid allows the use of virtually any local aggregate, eliminating the need to import higher
quality infill materials. Construction within 500 miles of GeoProducts' Houston, Texas
manufacturing facility can also apply the EnviroGrid geocell itself to the percentage contributing
to LEED credit.

Please visit our website (http://www.geoproducts.org/EnvironmentalMerit.aspx)for additional
information on the sustainability and environmental merit of EnviroGrid including LEED Green
Building Credits and more.














16 | P a g e
2013 Geo Products, LLC
Installation Procedures
Before Starting
1. Ensure that the site conditions and the EnviroGrid earth retention system layout are as
indicated on the construction drawings.
2. Ensure that all specified materials and system components are delivered to the site.
Site and Subgrade Preparation
1. Start site preparation for the EnviroGrid earth retention system installation by removing
debris and vegetative cover from the installation area.
2. Complete initial earthworks, excavation, or fills, according to plans.
3. Remove in-situ soils that are unacceptable for the EnviroGrid earth retention system
foundation and replace with suitable materials.
4. Prepare the foundation soils as specified prior to base material placement.
Installation of the Footing
1. Expand the specified EnviroGrid footing section into its designated position.
2. Hold the expanded EnviroGrid footing section open using one of the following options:
Straight stakes or J-Pins
Envirobars
Other options are also acceptable.






Envirobars
17 | P a g e
2013 Geo Products, LLC
3. Overfill the EnviroGrid footing section with the specified infill material and level to
approximately 50 mm (2 inches) above the cell wall.






4. Place infill material around the EnviroGrid footing section. Ensure that placement of this
material does not conflict with placement of the drainage system.
5. Compact fill and infill material to 95% of SPDD (Standard Proctor Dry Density) using
conventional equipment and materials.
Installation of the Drainage System
1. Install specified sub-drain pipe at the location and elevation shown on the construction
drawings ensuring that a minimum gradient of 2% is maintained to all free outlets.
2. Ensure that all pipe connections are properly made and that the sub-drain pipe is connected
to outlet pipes or an existing and functional subsurface drainage system.
3. Where specified, encapsulate the sub-drain pipe with a geotextile wrapped bedding material.
(e.g. sand, pea gravel, clear stone, etc.)
4. Wrap all outlet pipes passing through the wall face with a suitable geotextile to prevent loss
of the cell infill material.
5. Ensure that the discharge of the outlet end will not cause localized erosion that may affect
the stability of the EnviroGrid wall.




18 | P a g e
2013 Geo Products, LLC
Excavation Protection and Drainage
1. Where specified, place a suitable geotextile over the base and on the cut slope behind the
EnviroGrid wall.
2. Where specified, install the appropriate drainage composite materials. Ensure that the
system is functional and connected to a suitable outlet or sub-drain system.
Installation of the EnviroGrid Sections
1. Expand the specified EnviroGrid wall section into its designated position.
2. Hold the expanded EnviroGrid wall section open using one of the following options. Other
options are also acceptable.
Straight stakes or J-Pins
Evirobars
3. Check each EnviroGrid wall section to ensure that it is fully expanded.
4. Correctly align and interleaf edges of adjoining EnviroGrid wall sections and ensure that the
upper surface of the adjoining sections is flush.







5. Fasten EnviroGrid wall sections together with staples or as
specified on the construction drawings.
6. Overfill the EnviroGrid wall section with the specified infill
material and level to approximately 50 mm (2 inches) above
the cell wall.
19 | P a g e
2013 Geo Products, LLC
7. Compact the infill material to 95% of SPDD using conventional compaction equipment and
methods.




8. Place specified backfill material behind the EnviroGrid wall sections and compact to 95% of
SPDD.
In cut areas, extend the backfill materials back to the cut slope.
In fill areas, place backfill materials as specified on the construction drawings.
9. Heavy compaction equipment can be used to compact backfill materials to within 1 meter (3
feet) of the EnviroGrid wall sections. Use lighter walk-behind compaction equipment to
compact infill and backfill materials directly behind the wall sections.
10. After compaction of each layer, remove excess materials off the top of the EnviroGrid wall
section so that the top of the cellular structure is visible.
11. When positioning the next layer, ensure that:
* The proper setback of each layer is maintained.
* Proper side-to-side cell alignment is maintained to prevent loss of cell infill material.
12. When installing freestanding or very steep EnviroGrid wall structures, a 40 cm (16 inch)
strip of non-woven geotextile should be laid over the outer row of cells in each layer to prevent
loss of infill material.
13. When special infill material (such as topsoil) is required in the exposed row of face cells, the
following construction techniques may be employed:
Cover the outer cells with movable boards to prevent the interior-cell infill material
from spilling into the cells requiring the special infill. After completing compaction
remove the boards and fill the empty cells with the special infill.
Each layer should be opened and infilled separately starting with the lowest layer and
working to the upper layers.
20 | P a g e
2013 Geo Products, LLC













Installation of Geosynthetic Reinforcement (when required by design)
1. Place precut sections of geosynthetic reinforcement (woven geotextiles or geogrids),
dimensioned and oriented according to construction drawings, between the specified
EnviroGrid layers. It is important that reinforcement layers are:
Placed horizontally with the high-strength axis perpendicular to the wall face.
Flat and free from folds after placement.
Placed so that the leading edge is within 150 mm (6 inches) minimum of the front of the wall
and extend horizontally into the compacted backfill zone.
Place and infill the next EnviroGrid wall section layer.
Manually tension the reinforcement by pulling it back from the in filled EnviroGrid wall
sections.
Pin the back edge of the reinforcement layer so that it is taut and free from loose folds.
21 | P a g e
2013 Geo Products, LLC
Tracked equipment should operate within the reinforced backfill zone only after a minimum
150 mm (6 inches) have been placed over each reinforcement layer.
Rubber tired equipment can operate directly on the reinforcement using care to avoid sudden
stops and sharp turns.
Place backfill over the reinforcement in lifts of 250 mm (10 inches) starting from behind the
EnviroGrid wall sections and spreading the backfill towards the back of the reinforced zone.
Ensure that excessive displacement of the reinforcement does not occur during backfill
placement.
Shape and compact the infill material to 95% SPDD using conventional equipment and
methods.
Continue with this sequence until the EnviroGrid retaining wall is complete.


Geo Products, LLC provides this information only as an accommodation to our customers. No warranty or other
representation regarding the suitability of the application procedures is made due to the fact that each installation has
specific requirements that may not have been considered in this generalized procedure. Geo Products, LLC makes no
warranties or representations regarding the suitability of its EnviroGrid for specific uses or applications. Our liability is
limited to furnishing, without charge, a replacement for any EnviroGrid that is proven defective under normal use and
service.