The Thermo Scientic ISQ Single
Quadrupole Mass Spectrometer
system with ExtractaBrite

ion source
offers unstoppable productivity and
performance. The mass spectrometer
comes paired with the Thermo
Scientic TRACE 1300 GC or
TRACE 1310 GC, which both offer
the unique exibility of injector and
detector modularity. Add a Thermo
Scientic AI/AS 1310 autosampler
for automated liquid injection or
the Thermo Scientic TriPlus RSH
autosampler for automated sample
handling to obtain the ultimate in
analytical productivity.
C H R O M A T O G R A P H Y
Thermo Scientic
ISQ Single Quadrupole GC-MS
Advanced GC-MS system designed for continuous
high-throughput operation
ISQ

Single Quadrupole Mass


Spectrometer
Mode (Standard)
Electron Ionization (EI), with full scan, SIM, and
sequential full scan/SIM
Modes (Optional)
Chemical ionization, including PCI, NCI, Thermo
Scientic PPINICI and EI/CI Combination
Ion Source Type
Thermo Scientic ExtractaBrite EI source,
with repeller, source lenses, RF lens and dual
laments in all ionization modes, programmable
to 350 C
Source Access
Vacuum probe interlock to remove entire source
or change ionization modes without venting
Optional combination EI/CI source used for both
modes without interchange
Mass Filter
Dual-stage mass lter with off-axis ion guide
for noise reduction and solid, homogeneous
non-coated quadrupole rods
Detector
DynaMax XR detection system, with off-axis
dynode, discrete dynode electron multiplier and
electrometer, linear from 0 to 68 A
Mass Range
1.21100 u with unit mass resolution
Acquisition Rate
Ability to acquire more than 240 scans/sec
in SIM
Ability to acquire more than 65 scans/sec in full
scan when scanning over a range of 125 u
Pumping Systems
Standard capacity (>60 L/s), or extended
capacity (300 L/s) turbomolecular pump with
3.3 m
3
/h mechanical pump
Optional oil-free scroll pump
Reagent Gas Capabilities
Software-switchable dual reagent gas with digital
ow control
Ammonia, methane, isobutane and carbon
dioxide presets
Electron Energy
Adjustable from 0 eV to 150 eV
Emission Current
Up to 350 A, with improved regulation at low
current
Transfer Line Temperature
Up to 400 C
Gas Chromatograph
(TRACE

1300 GC or TRACE 1310 GC)


Please refer to GC and autosampler specication
sheets for additional details
TRACE 1300 GC: Intuitive, single-button start/
stop instrument for ease of use with minimal
local instrument interaction
TRACE 1310 GC: Complete icon-driven touch
screen user interface for direct local instrument
control
Instant Connect Injector Modules
Ability to swap or replace entire injector assembly
in less than 2 minutes.
Split/Splitless and multi-mode (including
on-column) Programmed Temperature Vaporizing
(PTV) available
Integrated backush optional for both S/SL
and PTV
1000 kpa digitally controlled carrier gas with
gas saver and septum purge
Autosampler
AI/AS 1310, TriPlus

RSH, and more


Oven Temperature
Operating temperature Range: Ambient +3 C
to 450 C
Cryogenic Option Minimum Temperature:
-100 C with LN
2
; -50 C with liquid CO
2
Oven Ramps/Plateaus Cool down
Number of ramps/plateaus: 32/33
Maximum heating rate: 125 C/min
T Range C Heating Rate C/min
Model: 220 Volts Model: 110 Volts
50 to 70 125 90
70 to 115 100 65
115 to 175 80 50
175 to 300 50 30
300 to 450* 35 20
GC Analytical Performance
Retention Time Repeatability: <0.0008 min
Peak Area Repeatability: <0.5 % RSD
Hydrogen Sensor Option
Optional hydrogen sensor suggested for use with
hydrogen carrier gas on both TRACE 1300 and
TRACE 1310 GC with the ISQ MS
Instant Connect Detector Modules
Detectors Available: Flame Ionization Detector,
Thermal Conductivity Detector, Electron Capture
Detector, Nitrogen Phosphorus Detector
Ability to add, swap or replace entire detector
assembly in less than 2 minutes
Fast Data Acquisition Rate: up to 300 Hz for FID,
TCD, ECD, and NPD
Data System Software and Options
Thermo Scientic Xcalibur Data system, common
platform for all Thermo Scientic MS systems
Thermo Scientic TraceFinder Software for
routine GC-MS quantication
TraceFinder

Software for Environmental and


Food Safety
TraceFinder Software for Clinical Research
Instrument control and data connection via Ethernet
Computer supplied with instrument equipped
with three Ethernet (8P8C RJ-45) ports
Commercial mass spectral library options,
including the following:
NIST libraries
Wiley libraries
Mass Spectral and GC Data of Drugs,
Poisons, Pesticides, Pollutants and Their
Metabolites (Maurer-Peger-Weber library)
Direct Sample Probe System Option
Switch to probe in under three minutes with GC
interface undisturbed
Available in two styles: rapid heating lament
Direct-Exposure Probe (DEP, capable of ash
vaporization or pyrolysis at up to 1000 C) or
slower volatilization Direct-Insertion Probe (DIP,
capable of accommodating powders and solid
samples in a quartz crucible)
Standard Installation Specications*
Electron Ionization
1 L of 1 pg/L octauoronaphthalene (OFN) will
produce the following minimum signal to noise
for m/z 272 when scanning from 50 to 300 u:
600:1 using helium as carrier gas
Positive Chemical Ionization
1 L of 100 pg/L benzophenone will produce the
following minimum signal to noise for m/z 183
when scanning from 80 to 230 u using methane
reagent gas: 300:1 using helium as carrier gas
Negative Chemical Ionization
2 L of 100 fg/L of OFN will produce the
following minimum signal to noise for m/z 272
when scanning from 50 to 300 u using methane
reagent gas: 600:1 using helium as carrier gas
System Dimensions/Weights
Total width of the connected GC/MS system is
80 cm (31 in). Allow 16 cm (6 in) of clearance
behind the instrument (32 cm if using autosampler).
Additional space should be allotted for data system
and printer.
Mass Spectrometer
(height width depth)
44 33 63 cm (17.5 13 24.5 in)
Weight: 43 kg (94 lbs)
TRACE 1300 GC
45 44 60 cm (18 17 24 in)
Weight: 35 kg (77 lbs)
TRACE 1310 GC
45 44 67 cm (18 17 26 in)
Weight: 35 kg (77 lbs)
P
r
o
d
u
c
t

S
p
e
c
i
f
i
c
a
t
i
o
n
s
* Helium standard specications are performed using a 15 0.25 mm i.d. 0.25 mm System Qualication Column (SQC).
PS51872_E 05/12M
Africa-Other +27 11 570 1840
Australia +61 3 9757 4300
Austria +43 1 333 50 34 0
Belgium +32 53 73 42 41
Canada +1 800 530 8447
China +86 10 8419 3588
Denmark +45 70 23 62 60
Europe-Other +43 1 333 50 34 0
Finland/Norway/Sweden
+46 8 556 468 00
France +33 1 60 92 48 00
Germany +49 6103 408 1014
India +91 22 6742 9434
Italy +39 02 950 591
Japan +81 45 453 9100
Latin America +1 561 688 8700
Middle East +43 1 333 50 34 0
Netherlands +31 76 579 55 55
New Zealand +64 9 980 6700
Russia/CIS +43 1 333 50 34 0
South Africa +27 11 570 1840
Spain +34 914 845 965
Switzerland +41 61 716 77 00
UK +44 1442 233555
USA +1 800 532 4752
thermoscientific.com
2012 Thermo Fisher Scientic Inc. All rights reserved. ISO is a trademark of the International Standards Organization.
All other trademarks are the property of Thermo Fisher Scientic Inc. and its subsidiaries. Specications, terms and pricing are
subject to change. Not all products are available in all countries. Please consult your local sales representative for details.
Thermo Fisher Scientic,
Austin, TX USA is ISO Certied.

Вам также может понравиться