Вы находитесь на странице: 1из 31

ControlMaestro

2013
Release Notes




Release notes of the new features and
improvements of the new ControlMaestro
2013 version






ControlMaestro 2013 Release notes v01A 26/06/2013 Page 1
ControlMaestro 2013
Release Notes v01A
Contents

1. Prerequisites for installation ........................................................................................................... 3
2. Installation instructions .................................................................................................................. 3
3. New features ................................................................................................................................... 4
3.1. Studio ...................................................................................................................................... 4
3.1.1. Multi Edit Tags and Alarms ................................................................................................. 4
3.1.2. Image Shortcuts .................................................................................................................. 4
3.1.3. PNG support ........................................................................................................................ 4
3.1.4. Image Animation Format .................................................................................................... 5
3.1.5. Remote Desktop.................................................................................................................. 5
3.1.6. Online Logged User ............................................................................................................. 6
3.1.7. Errors Files ........................................................................................................................... 6
3.2. LDAP ........................................................................................................................................ 6
3.2.1. Online connection ............................................................................................................... 6
3.2.2. Offline connection ............................................................................................................... 6
3.2.3. New user management parameters ................................................................................... 7
3.2.4. Changing LDAP password from ControlMaestro ................................................................ 7
3.2.5. Password expiration notification ........................................................................................ 9
3.3. HTML template ..................................................................................................................... 10
3.4. Alarms ................................................................................................................................... 11
3.4.1. Alarms in SQL .................................................................................................................... 11
3.4.2. Remote SQL ....................................................................................................................... 11
3.4.3. Station Properties VFI .................................................................................................... 11
3.4.4. SQL Server setup ............................................................................................................... 12
3.4.5. SQL Management Tools .................................................................................................... 12





ControlMaestro 2013 Release notes v01A 26/06/2013 Page 2
ControlMaestro 2013 Technical notes
3.4.6. Alarms Acknowledgment .................................................................................................. 13
3.4.7. Alarms Inhibition with Time Out ....................................................................................... 14
3.4.8. System Alarms ................................................................................................................... 14
3.4.8.1. Central UM Connection Loss System Alarm ................................................................. 14
3.4.8.2. Hardware Protection Loss System Alarm ...................................................................... 15
3.5. Audit Trail .............................................................................................................................. 15
3.5.1. Alarm Management actions .............................................................................................. 15
3.5.2. Filter actions to log............................................................................................................ 16
3.5.3. Tag Assign action ............................................................................................................... 17
3.6. New languages: Hungarian and Portuguese ......................................................................... 17
3.7. Drivers ................................................................................................................................... 17
3.7.1. OPC Generating custom alarms ........................................................................................ 17
3.8. BACnet B-AWS certification .................................................................................................. 20
3.8.1. BACstac update ................................................................................................................. 20
3.8.2. BACnet BAWS 2009 Certification ...................................................................................... 20
3.8.3. Improved BACnet COVP .................................................................................................... 20
3.8.4. BACnet dynamic window .................................................................................................. 20
3.8.5. Other driver enhancements .............................................................................................. 21
3.9. Web Components ................................................................................................................. 22
3.9.1. EWP Web Service Configuration ....................................................................................... 22
3.9.2. EWP Web Components Log on ......................................................................................... 23
3.9.3. List Viewer ......................................................................................................................... 23
3.9.3.1. Configuration ............................................................................................................ 24
3.9.3.2. Actions....................................................................................................................... 24
3.9.4. BACnet UI HTML ................................................................................................................ 24
3.9.5. Event Viewer ..................................................................................................................... 25
3.9.6. Configuration ................................................................................................................ 25
3.9.7. Actions........................................................................................................................... 27
4. Changelog...................................................................................................................................... 28








ControlMaestro 2013 Release notes v01A 26/06/2013 Page 3
1. Prerequisites for installation
A back-up of the existing installation must be made prior to installation.

Supported Operating Systems and SQL servers
Windows 2008 server R2 (multi-language, 64 bit)
Windows 2003 server R2 SP1 (multi-language, 32 bit)
Windows 7 SP1 or higher (multi-language, 32 bit and 64 bits)
Windows XP SP3 or higher (multi-language, 32 bit)
SQL Server 2005, 2008, 2008 R2, 2012 : all versions including Express Edition

Operating environment
It is strongly recommended that you install ControlMaestro only on the machine (hardware or virtual)
used for your project. It is also recommended to use a 64 bit operating system.

System requirements
N.B.: The Windows Operating System installed may require more resources than those
recommended for ControlMaestro (for example Windows 2008 R2 Server I7 processor / 8GB RAM).

Processor: Intel I5 2.1 GHz (recommended: Intel I7 2.4 GHz or higher). ControlMaestro
supports multi-processor architectures, dual-core processors, chipsets using 'hyper-
threading' technology.
Memory: 4 GB (8 GB recommended).
Hard disk: min. 500 GB.
Graphic card: 512 MB (1 GB recommended).
Monitor resolution: 1280 x 1024 or higher (1920 x 1080 recommended).
Mouse: any PC-compatible mouse.
USB port: required for the dongle.
TCP/IP configuration: IP address can be fixed or provided by a DHCP server.
Web server: a web server is required for publishing the application. MS IIS (Internet
Information Server) version 7 or higher is recommended.
Browser: Java and JavaScript must be activated. Cookies should be allowed. For Control
Maestro web pages, any browser with JAVA plug-in is supported.
Internet Explorer version 8 minimum
2. Installation instructions
1. Close all ControlMaestro applications.
2. Close all other applications and disable any anti-virus programs.
3. If an existing application has been upgraded, read the document carefully.
4. Run the installation program.
5. Follow the instructions.





ControlMaestro 2013 Release notes v01A 26/06/2013 Page 4
ControlMaestro 2013 Technical notes
3. New features
3.1. Studio
3.1.1. Multi Edit Tags and Alarms
It is possible to select multiple elements and change their common properties to do so, select
multiple tags or alarms, right click and select Modify.

Properties that can be changed:
Tag: group, sample, tag type, record, start-up value, lock, alarm, multi-state, SoftPLC
(without name and address);
Alarm: All properties except alarm condition and alarm description.

The properties that cannot be changed are locked (disable).
The properties that have been changed are highlighted in yellow.
3.1.2. Image Shortcuts
In Image editing mode, the following shortcuts are added:
Ctrl+E Display the selected item(s) Properties.
Ctrl+PageUp Bring to Foreground the selected item(s).
Ctrl+PageDown Send to Background the selected item(s).
F11 Toggle display of toolboxes (hide the toolboxes currently displayed / restore the hidden
toolboxes).
F12 Toggle full-window mode (remove all the toolbars, status bar, and border / restore the
hidden bars and border).
Shift+<Arrow> Move the selected item(s) in the direction given by the <Arrow>. <Arrow> can
be one of the following keys: Left, Right, Up or Down.
Ctrl+Shift+<Arrow> Same as Shift+<Arrow>, but 'faster' (step of moving is higher).

All these new shortcuts are enabled by default. They can be disabled by adding the following line in
apptune.dat:
DISABLE_SHORTCUTS=YES
Note: adding this option will disable only these new shortcuts. The shortcuts from former releases
will remain active.
3.1.3. PNG support
PNG Image file format is now supported for the images. It can be used in both Web and Studio
images.
Please note that when PNG images are used in web, they will use the alpha transparency channel
contained in the image itself, whereas in the studio background transparency has to be defined.







ControlMaestro 2013 Release notes v01A 26/06/2013 Page 5
3.1.4. Image Animation Format
It is possible to create an animation based on a .zip package containing several png pictures.
When importing the ILS file, it will rely on the existing OBJECT SGF type. A .zip package will be
referenced. The .zip package will be standard zip with no password. ZIP Package will contain flat files
with no hierarchy. The PNG files must have the same size in width/height.
The transparency color (R,G,B) will apply to all images in the package, so they must be created that
way. One file will be used for configuration, config.xml.

ILS Example:
OBJECTS:
OBJECT SGF 1 {
TRANSPARENT COLOR = (255,255,255) LAYER="BASE" [ <5120,-19968> <22759,3561> ]
".\ventilation_on.zip|mytagName_canBeOptional "
}

Config.xml example:
<?xml version="1.0" encoding="UTF-8" ?>
<Animation>
<Default timer="500">
<Image filename=001.png/>
<Image filename=002.png/>
<Image filename=003.png/>
</Default>
<Interval start="10" end="19" timer="500">
<Image filename=004.png/>
<Image filename=005.png/>
<Image filename=006.png/>
<Image filename=007.png/>
</Interval>
<Interval start="20" end="49" timer="300">
<Image filename=004.png/>
<Image filename=005.png/>
</Interval>
<Interval start="50" end="100" timer="100">
<Image filename=004.png/>
<Image filename=007.png/>
</Interval>
</Animation>
3.1.5. Remote Desktop
Dongle can be used with Remote Desktop. User can use the RUS tool and start ControlMaestro
while working through RDP connection.





ControlMaestro 2013 Release notes v01A 26/06/2013 Page 6
ControlMaestro 2013 Technical notes
3.1.6. Online Logged User
In a Web project, it is possible to display the local logged-in user. The tag SYS_OPERATOR is used to
display the user name online when the internet browser is being used, and it works per session.
3.1.7. Errors Files
Errors files management has been improved:
A new folder "\Logs" is created in the project and will contains per sessions logs file in compressed
format (zip). At application start-up, errors.dat file from previous session is zipped and moved to the
Logs folder. The file is renamed as errors_YYYY-MM-DD_hh-mm-ss.zip with date and time of the
zipping action.
Errors parameters are now applied to the \Logs folder:
Size of files in Logs folder exceed the Maximum Historical Size, the oldest files are deleted.
Number of files in Logs folder exceed the Maximum Session Count, the oldest files are
deleted.
3.2. LDAP
LDAP import from Active Directory has been improved:
User interface enhancements for synchronization:
- Possibility to filter users and groups list for easier selection.
Performance improvements for synchronization:
- Using SSL connection for security and paginated mode to retrieve users in order to
handle big directories efficiently.
Use of password expiration from LDAP:
- Password validity is using expiration date from LDAP server. If server is offline, a
grace period can be set to allow offline login.
3.2.1. Online connection
When an operator or an application developer successfully authenticates in ControlMaestro with his
LDAP identity, he will be prompted to change his password if it has expired. Until the user enters a
correct new password, he will not be able to authenticate himself.
When an operator or an application developer successfully authenticates in ControlMaestro with his
LDAP identity, if his password reached its expiration date notification, the user will
be notified and be offered to change his password.
From now on, once a user is authenticated, his LDAP user name and password will be cached in
ControlMaestro. For security reasons, the password is encrypted using MD5. These data is valid for a
fixed limit of time.
3.2.2. Offline connection
An operator or an application developer will be able to authenticate in ControlMaestro when the
LDAP is not reachable. This feature requires two conditions:
The user must have authenticated himself in online mode in a previous session in order to have his
identity cached in ControlMaestro.
The cached data needs to still be valid: it expires when the expiration date has passed.
The offline connection status will be notified to the current user by displaying a warning dialog box.






ControlMaestro 2013 Release notes v01A 26/06/2013 Page 7
Note: the reason why the Windows AD server is not reachable will not be displayed to the user.
3.2.3. New user management parameters
In user management properties, a new group box LDAP bidirectional connection management is
added. Inside this group box, two new fields are created:
Cached data is valid for [10..30]: days
Password expiration reminder [3..14]: days


3.2.4. Changing LDAP password from ControlMaestro
An operator will be able to change his LDAP account password inside ControlMaestro in runtime
mode only (not available from the studio), using the new fast action: ChangeLdapPassword. This
feature will be available both in studio image and web application.









ControlMaestro 2013 Release notes v01A 26/06/2013 Page 8
ControlMaestro 2013 Technical notes
This fast action can be called in two different configurations:
Change current user password: user name field is disabled.
Change user password: user name is enabled, allowing any LDAP user to change his
password.

ChangeLdapPassword will inform the user of the following events by displaying a warning dialog box:
Unknown user or incorrect old password.
New password and confirm password do not match.
Password cannot be changed, cached password is not valid: this might happen if the user did
change his LDAP password on a different station whereas he was authenticated in
ControlMaestro.

Note: No other error message will be displayed.
Important: Modifying user password requires the Windows AD to support TLS in 128 bits on port
636.







ControlMaestro 2013 Release notes v01A 26/06/2013 Page 9
3.2.5. Password expiration notification
Notification of current user password expiration will be processed in a system alarm object. The
alarm will be raised when ControlMaestro detects that the current user password has expired. The
expiration date notification will be displayed on login in online mode only.

A new tab is added for LDAP password expiration.


Password expiration notification.







ControlMaestro 2013 Release notes v01A 26/06/2013 Page 10
ControlMaestro 2013 Technical notes
3.3. HTML template
The HTML template has been redesigned to allow users to use their own report template and
perfect the printed version.

It is now possible to add some HTML types which can be defined as header, footer and approval.
Three directories: Header, Footer and Approval files are found in the product installation
HTML template folder.

These files can be chosen when generating a new HTML Template.


It is now possible to choose between the following modes:
Default: as previously, the configuration from the event summary is used.
Start: a new summary is added with the filters saved in the event summary properties, but
all alarms started in the date range are defined during generation.
End: a new summary is added with the filters saved in the event summary properties, but all
alarms ended in the date range are defined during generation.
Ack: a new summary is added with the filters saved in the event summary properties, but all
alarms acknowledged in the date range are defined during generation.

Note:
When printing an event summary which displays comments: a new row containing the full comment
is added below the alarm.







ControlMaestro 2013 Release notes v01A 26/06/2013 Page 11
3.4. Alarms
3.4.1. Alarms in SQL
Alarms history can now be archived in SQL Database. SQL History format is applied for Tags and
Alarms at the same time.
Note project on migration:
At start-up, if the project was using SQL for Tags history, then Alarms history will also use SQL. By
default the DSN will be the same as the one used for Tags.
3.4.2. Remote SQL
ControlMaestro can now relies on distant SQL Server Databases.
In order to allow multiple applications to connect to the same remote server and to avoid any
overwriting of databases, a prefix must be added to the database name for each application.
Note:
When a remote server is used to store the databases, it is not allowed to attach and detach them.
Before launching the application, the databases must be created or attached manually on the distant
server. Naming convention: prefix_VfiTag and prefix_VfiAlarm.
3.4.3. Station Properties VFI
When SQL format is selected, it is no longer allowed to use back other formats. Therefore, all
controls related to Other Formats are disabled.







ControlMaestro 2013 Release notes v01A 26/06/2013 Page 12
ControlMaestro 2013 Technical notes
3.4.4. SQL Server setup
The SQL Server Setup dialog box is now used to configure Tags or Alarms connections for both local
and remote SQL Servers.



In that example, the databases will be named MASTER1_VfiTag or MASTER1_VfiAlarm.
3.4.5. SQL Management Tools
As for Tags, actions available for Alarms management are: backup/restore/import.







ControlMaestro 2013 Release notes v01A 26/06/2013 Page 13
3.4.6. Alarms Acknowledgment
Two options, Force Comment and Force Sign In are added to the alarms definition, in order to
force the user to sign in and/or to enter a comment to the alarm when acknowledging.



When acknowledging, the Force Sign in dialog box asks the user to confirm its password, when at
least one of the selected alarms has the option Force Sign In activated.



When acknowledging, the Force Comment Dialog Box asks the user to enter a comment when at
least one of the selected alarms has the option Force Comment activated.







ControlMaestro 2013 Release notes v01A 26/06/2013 Page 14
ControlMaestro 2013 Technical notes
3.4.7. Alarms Inhibition with Time Out
After a defined timeout, in millisecond, a tag will not inhibit an alarm anymore even if the condition
is still valid.



The maximum value is 4294967295 milliseconds (about 49 days).
3.4.8. System Alarms
The System Alarms configuration has been improved, all system alarms tabs are grouped into one
tab System Alarms.



3.4.8.1. Central UM Connection Loss System Alarm
When the application loose the connection to the central UM database, a system alarm "Connection
to the User Management central database has been lost" is raised.






ControlMaestro 2013 Release notes v01A 26/06/2013 Page 15
3.4.8.2. Hardware Protection Loss System Alarm
When the application loses its hardware Protection dongle, a system alarm "License hardware key
could not be found!" is raised.
3.5. Audit Trail
3.5.1. Alarm Management actions
The category Alarm Management Actions is added to the audit trail, with 4 actions:
Acknowledge alarm from Image, Event Summary or Auto acknowledgement:
o Time = Acknowledge time
o User = User that acknowledged the alarm (for AutoAck alarm, User = AutoAck)
o Info1 = Alarm description
o Info2 = Alarm family
Note: All alarm information can be retrieved with Alarm history.
Alarm Definition Modification:
o Info1 = Previous alarm Family
o PreviousTagStr = Previous alarm Condition
o Info2 = New alarm Family
o TagStr = New alarm Condition
o User = User that modified the alarm
Alarm Definition Creation:
o Info2 = New alarm Family
o TagStr = New alarm Condition
o User = User that created the alarm
Alarm Definition Deletion:
o Info1 = Previous alarm Family
o PreviousTagStr = Previous alarm Condition
o User = User that deleted the alarm






ControlMaestro 2013 Release notes v01A 26/06/2013 Page 16
ControlMaestro 2013 Technical notes

3.5.2. Filter actions to log
Audit Trail actions can be filtered for logging.
The dialog box has been updated: Station Properties Audit Trail.

By default, Enable Filter Actions to Log is unchecked all types of Audit Trail actions are logged.







ControlMaestro 2013 Release notes v01A 26/06/2013 Page 17
3.5.3. Tag Assign action
The Tag Assign action is now logged from:
Single Tag dialog box in Studio
MultipleTag dialog box in Studio
TagLock dialog box in Image
Fast action Set tag Value
List Viewer
3.6. New languages: Hungarian and Portuguese
ControlMaestro is now available in Hungarian and Portuguese.
This language has been added to the current set of available languages:
English
French
German
Italian
Spanish
Hebrew
Japanese
Korean
Czech
Polish
Russian
Chinese
Hungarian
Portuguese
3.7. Drivers
3.7.1. OPC Generating custom alarms
The OPC AE client has been improved to allow the user to choose all attributes of the generated
alarm.







ControlMaestro 2013 Release notes v01A 26/06/2013 Page 18
ControlMaestro 2013 Technical notes


The new dialogue box enables the selection of all attributes of the alarm:



Notes:
For the Text and Family edit fields it is now possible to choose a combination of the OPC Event
properties. By typing the % character a context menu appears with the available event properties,
and once validated the chosen property is enclosed by the% character (so when the alarm is
generated all the properties enclosed by % are replaced by the value of the chosen property of the
released event). For a list of all available properties and their description, see section 5.6.1.1.1 of the
OPC AE 1.1 Specification. The properties are listed below:
wChangeMask, wNewState, szSourceName, ftTime, szMessage, dwEventType, dwEventCategory, dwSeverity,
szConditionName, szSubconditionName, wQuality, bAckRequired, ftActiveTime, dwCookie, szActorID.

The following dialogue boxes appear by clicking consecutively on the buttons Edit groups, Edit
user fields and Action on alarm:







ControlMaestro 2013 Release notes v01A 26/06/2013 Page 19









ControlMaestro 2013 Release notes v01A 26/06/2013 Page 20
ControlMaestro 2013 Technical notes
3.8. BACnet B-AWS certification
3.8.1. BACstac update
The ControlMaestro BACnet driver now uses the latest version of BACstac. (version 6.3d).
The BACstac setup is located under the program installation folder: \Bin\Drivers\Bacnet install
3.8.2. BACnet BAWS 2009 Certification
ControlMaestro 2013 and its BACnet driver are BACnet BAWS 2009 certified. The product
successfully passed the tests for Certification 2009. To qualify for this, we added some features:

Using DS-WPM-A
Upgrade for DS-AV-A & DS-AM-A
Upgrade for AE-AVN-A
Upgrade for AE-AVM-A
Using AE-ELVM-A & T-AVM-A
Check SCHED-AVMA
3.8.3. Improved BACnet COVP
To use the complete capabilities of ELUTIONS and BACnet devices, the driver uses the COVP feature.
Define a tag In Monitor linked to a BACnet Object Property in COV mode, and it will automatically be
used as in monitoring with COV mode. That means that dynamic subscription is performed on the
device.
3.8.4. BACnet dynamic window
The BACnet dynamic window has been completely redesigned. It is available both in Java and HTML.
It allows viewing and modifying all property values of an object.

As an example, here is the LOOP object displayed in the BACnet HTML window.






ControlMaestro 2013 Release notes v01A 26/06/2013 Page 21


3.8.5. Other driver enhancements
COV in monitor: this allows to subscribe COV for a tag only when its used (viewed in an
image for example).
New objects and properties of 2009 standard version are integrated.
Display of ControlMaestro alarm classes and user field names in interface.
Better handling of master/backup.
Object Generator: use of max-pres-value and min-pres-value of EDE to set tag limits.
New value types like octet-string, timestamp, address-binding are now editable.
Ability to store string values from trend-log into tag history, and support for trendlog-
multiple objects.
Single array item edition is now possible from BCC.
Support of record-access method to read and write file objects.
BACnet event details can be stored as comments in alarm history.
And many fixes to improve reliability, performance.






ControlMaestro 2013 Release notes v01A 26/06/2013 Page 22
ControlMaestro 2013 Technical notes
3.9. Web Components
3.9.1. EWP Web Service Configuration
The EWP Service Configuration is a wizard to configure the EWP Web Service. The configuration
interface is launched from the control Panel of ControlMaestro 2013.


The interface allows you to configure a database. You can select a local or remote database server,
his name, and configure the connection to the database. After validating the connection, you can
Start/Stop/Restart the EWP service and select the log level.









ControlMaestro 2013 Release notes v01A 26/06/2013 Page 23
3.9.2. EWP Web Components Log on
From the toolbar, click on the following button to start EWP web site.

3.9.3. List Viewer
The List Viewer is a new web application based completely on HTML 5 (works on all web browsers as
well as smartphones and tablets) that allows users to display data point lists with values. Within the
viewer it is possible to open Java images, Java charts and other elements where a data point is used.
The data point values can be modified from here and all data point information is displayed, such as
alarms, etc.










ControlMaestro 2013 Release notes v01A 26/06/2013 Page 24
ControlMaestro 2013 Technical notes
3.9.3.1. Configuration


Allows to choose data points to be displayed directly through filters.
Allows to configure the column filters, etc.
3.9.3.2. Actions
The list of possible actions on selected one data point is:
Refresh : Unit is in seconds, refresh the list of data points displayed for the current tab
Clear Search : Clears the filters from the column headings and refreshes the grid
Event Summary : Displays the Event Summary defined in the configuration dialog
Configure : Shows the configure dialog above
Add to CMTrends : Adds the tag to the CMTrends addon (optional)
BACnet Object View : displays the BACnet object viewer for the selected tag
Goto Image : Loads an image linked to the tag
Tag Value : To set the tag value
History Viewer : Shows history of selected tag
Print Preview : Displays a prevent preview of loaded data.
Export : Exports loaded data as CSV
3.9.4. BACnet UI HTML
Allows to display Bacnet Objects in HTML from ListViewer.







ControlMaestro 2013 Release notes v01A 26/06/2013 Page 25
3.9.5. Event Viewer
The Event Viewer is a new web application based completely on HTML 5 (works on all web browsers
as well as smartphones and tablets) that allows users to display and control alarms. It relies on major
features from Event Summary.


Note:
Event Viewer will require to create new configurations, as it is independent from event summary.
3.9.6. Configuration
The Event Viewer requires that Alarms history are configured to use SQL. See Alarms in SQL,
above.

Filter Selection







ControlMaestro 2013 Release notes v01A 26/06/2013 Page 26
ControlMaestro 2013 Technical notes
Display Options

Configure Options







ControlMaestro 2013 Release notes v01A 26/06/2013 Page 27
3.9.7. Actions
The list of possible actions on one or multiple selected alarms is:
Refresh : Refresh the list of events displayed
Filters : Choose between live or historical events. Select live alarm filter. Select historical event
period, status, target, etc parameters
Display : Choose font, columns displayed, color of text and background, loading and access options
Configure : Choose allowed operations, action on double click, number of alarms to display, etc
Go to Zone : Loads the Java web image for an alarm
Assist : Displays an assist text file if defined in the alarm
Ack Selected : Acknowledges an alarm
Ack All : Acknowledges all alarms displayed in the Event Viewer
Force End : Ends an alarm
Messages : Allows user to add a message to the alarm list (or edit one that already exists)
Comments : Add comments to an alarm. View existing comments on an alarm
Inhibit Selected Alarm Levels : Inhibit the selected alarm
Alarm Level Inhibition : Inhibit alarms by their level
Set Handler Name : Set the handler name for an alarm
Print : Prints the alarms in the grid
Export : Exports the alarms in the grid








ControlMaestro 2013 Release notes v01A 26/06/2013 Page 28
ControlMaestro 2013 Technical notes
4. Changelog
ControlMaestro 2013 integrates all fixes from ControlMaestro 2011 update 28 plus the following
additional list.
Ticket
Number
Description
6203 Alarm texts with accents are corrupted in history alarm files after migration from CM2008 to CM20011.
6262 Macro are lost during a migration from CM2008 to CM2011 pp28 or CM2013 beta.
6250 History status filters from print menu from event summary in history mode has no sens
6244 Window "Alarm Definition: New alarm" opened after creation of a new alarm
6243 State property from tag with context has wrong animation through network
6241 LDAP: merge or overwrite possibility
6232 Multilanguage import gives wrong tag name
6231 In history mode, charts shows time and value in the future (using crosshair)
6227 Multi State displaying is limited to 100 in the tree view in the studio.
6219 Problem when more than one multistate defined
6190 BCC:Trendlog only after Restart visible in BBC history card
6154 German : The button Quiet in the web popup is not well translated
6107 Distant server should be replaced by remote server in VFI.
6106 Local server are not shown when using VFI with Windows 7 64 bits.
6105 Multi states not visible when we want to add it to a tag.
6053 Active Directory : Label fail on first popup
6050 BACnet schedule state name with more than 6 characters are not correctly displayed (truncated)
5991 Crosshair behaves different in real time mode and non real time mode
5990 Number of BACnet alarms is false in event summary with web desktop
5966 Filteredtrigger use position of screen resolution
5950 When minimizing an image which was in full screen it is reloaded in small window.
5904 Severity of the event summary is changing (ex: from 100 to 50 000)
5890 Tooltips with tag context doesn't work in web
5868 No error message when 2 stations with same name and ID on the same Network.
5844 Alarm History are no more visible in the Web, but there are displayed in the event summary
5795 Audit Trail : Crash when trying to activate Audit Trail function
5766 Station Properties, User tab - Allow edit boxes (Default and logout user/password) to process Unicode
5758 Cluster: If you are using a formula 1-@ in the cluster definition, the instance will not correctly
5753 The Fast Action LoadHtmlPage use a default path instead of browsed path
5703 Charts : crash if we close a chart when the properties window is open
5702 HTML template: UTF8 user name doesn't supported in the Header and the Print Preview
5679 Missing macro in image is only showing 'missing macro (trigger)' in the .mis file without the Macro name
4415 Popup buzz for severity 50000 does not work
4238 On web image, transparent buttons have been displayed with white color.
3119 Default timeformat in alarm properties should be "DATE+TIME" instead of "DAY+TIME"
2027 AAM - user properties - there is a mix of icons for the different services



















www.elutions.com

ELUTIONS Inc.
601 E Twiggs Street,
Suite 300
Tampa, Fl 33602
USA
tel +1 (813) 419-5500
fax +1 (813) 419-5501
info@elutions.com
ELUTIONS
Parc Technologique de Lyon
12 alle Irne Joliot-Curie, Bt. B1
F-69791 Saint-Priest Cedex
France
tel +33 (0)4 72 47 98 98
fax +33 (0)4 72 47 98 99
info@elutions-europe.com
ELUTIONS BV
Concordiaweg 149-151
Postbus 351
NL-4200 AJ Gorinchem
Nederland
tel +31 (0)183 646 303
fax +31 (0)183 621 601
ELUTIONS Ltd
The Gate Hotel, Scotland Gate
Northumberland
NE62 5SS
UK
tel +44 (0)7730 767355

ELUTIONS Inc.
601 E Twiggs Street,
Suite 300
Tampa, Fl 33602
USA
tel +1 (813) 419-5500
fax +1 (813) 419-5501
info@elutions.com
ELUTIONS
Parc Technologique de Lyon
12 alle Irne Joliot-Curie, Bt. B1
F-69791 Saint-Priest Cedex
France
tel +33 (0)4 72 47 98 98
fax +33 (0)4 72 47 98 99
info@elutions-europe.com
ELUTIONS BV
Concordiaweg 149-151
Postbus 351
NL-4200 AJ Gorinchem
Nederland
tel +31 (0)183 646 303
fax +31 (0)183 621 601
ELUTIONS Ltd
The Gate Hotel, Scotland Gate
Northumberland
NE62 5SS
UK
tel +44 (0)7730 767355

Вам также может понравиться