Вы находитесь на странице: 1из 50

ROI-S05748-05GE CONTENTS

February, 2008
CL-1
PASOLINK NEO
6-52 GHz PDH/SDH DIGITAL RADIO SYSTEM
Section I DESCRIPTION
CONTENTS
TITLE PAGE
1 GENERAL DESCRIPTION 1-1
2 SYSTEM CONFIGURATION AND CHARACTERISTICS 2-1
2.1 System Configuration 2-1
2.2 Performance Characteristics 2-19
2.2.1 General System 2-19
2.2.2 LAN Interface (10/100 Base-T(X)) 2-21
2.2.3 LAN Interface (1000Base-SX/LX, 1000Base-T) (GbE) 2-25
2.2.4 Service Channel (SC) 2-26
2.2.5 LCT (PNMT) Interface 2-26
2.2.6 PNMS Interface 2-26
2.2.7 RF I/O Port 2-26
2.2.8 Parallel Alarm Interface 2-27
2.2.9 Wayside 2-27
2.2.10 ODU (Outdoor Unit) and System performance 2-28
2.2.11 IDU (Indoor Unit) and System performance 2-32
2.3 Interconnection between ODU and IDU 2-36
2.4 Hybrid Combiner/Divider 2-37
2.4.1 10 dB Coupler 2-38
2.4.2 OMT (Ortho-Mode Transducer) 2-39
2.5 RF Channel Plan 2-40
2.6 Power Supply 2-41
CONTENTS ROI-S05748
CL-2
2 pages
(This page is intentionally left blank.)
ROI-S05748 GENERAL DESCRIPTION
1-1
1. GENERAL DESCRIPTION
This section provides descriptive information on the PASOLINK NEO
radios which are used for the wide/narrow band point-to-point digital
microwave radio links.
The Indoor Unit (IDU) provides digital PDH (5-48 E1, 1/2 E3), SDH
(1 STM-1) and/or LAN (2P 10/100BASE-T(X), 4P 10/100BASE-
T(X) or 1P (1000BASE-SX/LX or 1000BASE-T)) signal transmission
by the change of the data signal interface card. It can select the modulation
method QPSK/16QAM/32QAM/128QAM, by software selection
depending on the transmission capacity that is configured in the
modulator/demodulator unit.
Note: For 52 GHz band, only QPSK is available.
The Outdoor Unit (ODU) can be applied for a wide range of RF frequency
bands from 6/7/8/10/11/13/15/18/23/26/32/38/52 GHz.
Applications using the following redundancy configurations, Unprotected
(1+0), 2 (1+0)*1, Protected (1+1), 2 (1+1)*1 and 2-WAY*2 are
available for PASOLINK NEO radio systems.
Notes: *1; XPIC
*2; 2-WAY/Cross-connect
Cross Polarization Interference Canceller (XPIC) system is applied for
dual polarized systems using the same frequency in 2 (1+0) and 2
(1+1) configurations.
GENERAL DESCRIPTION ROI-S05748
1-2
PASOLINK NEO
SELV
!
100M
AUX/ALM LCT NMS NE SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PASOLINK NEO
PORT 1 PORT 2 100M
ALM
2MIN/OUT-A 2MIN/OUT-B
PULL
G
G
G
IDU 1+1
SELV
!
100M
AUX/ALM LCT NMS NE SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PASOLINK NEO
PORT 1 PORT 2 100M
ALM
2MIN/OUT-A 2MIN/OUT-B
PULL
SELV
!
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PULL
G
G
G
G
IDU 1+0
(Blank)
MDP-150MB-1AA
WEIGHT: 4 kg
SER. No. 123456
INDOOR UNIT
48 V 2.5A
NEC Corporation TOKYO J APAN MADE IN J APAN
IDU Package Label
(Example)
IDU Name Plate
Note *1: When a 2-WAY label is put on the 16E1
INTFC, the 2-WAY/XC mode is available.
2-WAY
*1
0678
DATE 2007-09 (H2930)
(WITH OPTION)
(WITH ODU & OPTION)
(IDU)
ROI-S05748 GENERAL DESCRIPTION
1-3
TRP-6G-1B
OUTDOOR UNIT
SHIFT FREQ 161MHz SUB BAND
(NWA-009024)
0.5A
NEC Corporation MADE IN JAPAN
CAUTION
Non-ionizing
radiation
-48V INPUT
Power down IDU before
disconnection or
connection of cable.
PASOLINK NEO
SERIAL No.
PASOLINK NEO
FG
IFL MON
RX LEV
ODU NHG Type (For 6-38 GHz Band)
ODU Name Plate
For 52 GHz band, the TRP-52G-5A ODU
(Pasolink Mx) is used for NEO.
(ODU)
0678
(NHG)
TX LOW
123456
- 48V WEIGHT 4kg /
TX FREQ
DATE
A
7725MHz
2007-09
TOKYO JAPAN
TRP-52G-5A
OUTDOOR UNIT
SHIFT FREQ 661MHz SUB BAND
(H0356B)
0.5A
NEC Corporation MADE IN JAPAN
CAUTION
Non-ionizing
radiation
-48V INPUT
Power down IDU before
disconnection or
connection of cable.
PASOLINK Mx
SERIAL No.
0678
TX LOW
123456
- 48V WEIGHT 4kg /
TX FREQ
DATE
A
51454MHz
2007-09
TOKYO JAPAN
ODU Package Label
(Example)
-48V
IFL RX LEV MON
ODU NHG2 Type (For 6/7/8 GHz Band)
ODU NHG2 Type (For 13-38 GHz Band)
ODU Mx Type (For 52 GHz Band)
TRP-13G-5B
OUTDOOR UNIT
SHIFT FREQ 266MHz SUB BAND
(NWA-034278)
0.5A
NEC Corporation MADE IN JAPAN
CAUTION
Non-ionizi ng
radiation
PASOLINK NEO
SERIAL No.
0678
(NHG2)
TX LOW
123456
- 48V WEIGHT 3kg /
DATE
A
2008-01
TOKYO JAPAN
ODU NHG Type
ODU NHG2 Type
CAUTION
HOT SURFACE
Avoid contact.
TRP-13G-5B (NHG2)
266MHz
TRP-13G-5B SERIAL No.123456(NWA-034278-010-001)
NWA-34278-010-001
TRP-13G-5B
GENERAL DESCRIPTION ROI-S05748
1-4
4 pages
(This page is intentionally left blank.)
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-1
2. SYSTEM CONFIGURATION AND
CHARACTERISTICS
This section provides outline of the system configuration, system
performance, RF channel plan, external alarm items and House keeping
input/output, and power supply.
2.1 System Configuration
The system consists of the MDP-150MB-1AA Modulator-Demodulator
(Indoor Unit (IDU)) and TRP-(*1)G-1B/5B Transmitter-Receiver (Outdoor
Unit (ODU)), Hybrid Combiner/Devider*2 or Orthogonal Mode
Transducer (OMT)*3 and the antenna.
The TRP-( )G-1B (NHG Type) or TRP-( )G-5B (NHG2 Type) is available
with frequency bands of 6 GHz to 38 GHz. band and the TRP-52G-5A is
for 52 GHz.
Notes: *1:ODU Type depends on the frequency band used, such as
TRP-(13)G-1B (NHG Type) or TRP-(13)G-5B (NHG2 Type)
is applied for 13 GHz band.
*2:The Combiner/Divider is used in (1+1) single antenna
configuration for antenna direct mount type ODUs.
*3:The OMT is used in XPIC systems with antenna direct
mounting ODUs.
*4:The IDU CTRL F/W Ver3.4.xx or later version is required
when the TRP-( )G-5B ODU NHG2 Type is connected with
the NEO IDU. (Refer to 1.1 Accessing the PASOLINK NEO
in Section IV Appendix LCT Operation.)
Refer to
Fig. 2-1 Protected/Unprotected System Configuration (1/3)
Fig. 2-2 Signal Interface/Capacity (1/2)
Fig. 2-3 IDU e/w Standard and Optional Interface (1/3)
Fig. 2-4 Configuration of the ODU (1/4)
Fig. 2-6 System Block Diagram (1/5)
Fig. 2-7 Hybrid
Fig. 2-8 10 dB Coupler
Fig. 2-9 OMT Transducer
Fig. 2-10 Power Supply System Block Diagram (1/3)
Table 2-1 System General Performance (1/2)
Table 2-2 2 Port LAN 150 Mbps (128QAM)
Table 2-17 System Performance for 128QAM/ODU
Table 2-18 System Performance for IDU
Table 2-19 Alarm & House Keeping Output Items
Table 2-20 House keeping input Items
Table 2-22 Characteristics
Table 2-23 Characteristics
Table 2-24 Characteristics
Table 2-25 RF Frequencies
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-2
Fig. 2-1 Protected/Unprotected System Configuration (1/3)
ODU IDU
DATA
IN/OUT
1+0 IDU
IF Cable
ODU IDU
DATA
IN/OUT
1+0 IDU
IF Cable
ODU (Working)
HYB
No.1
DATA
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
IF Cable
No.2
ODU IDU
DATA
IN/OUT
1+0 IDU
IF Cable
ODU IDU
DATA
IN/OUT
1+0 IDU
IF Cable
f1
f1
ODU (Working)
HYB
No.1
DATA
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
IF Cable
No.2
f1
f1
f1
f1
ODU (Working)
HYB
No.1
DATA
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
IF Cable
No.2
ODU (Working)
No.1
DATA
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
IF Cable
No.2
f1
ODU (Working)
HYB
No.1
DATA
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
IF Cable
f1
f1
RF Cable
No.2
ODU (Working)
HYB
No.1
DATA
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
IF Cable
RF Cable
No.2
ODU (Working)
No.1
DATA
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
IF Cable
No.2
f1 ODU (Working)
No.1
DATA
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
IF Cable
No.2
f1
f1
f1
ODU (Working)
HYB
No.1
DATA
IN/OUT
ODU (Working)
1+1 IDU
IF Cable
IF Cable
No.2
ODU (Working)
HYB
No.1
DATA
IN/OUT
ODU (Working)
1+1 IDU
IF Cable
IF Cable
No.2
f1
f1
f2
f2
RF Cable
RF Cable
1+0 with Waveguide/Coaxial Cable Connection
1+0 with Antenna Direct Connection
1+1HS/HS with Coaxial Cable Connection
1+1 HS/HS with Antenna Direct Connection
1+1 HS/Hybrid SD with Antenna Direct Connection
1+1 HS SD with Antenna Direct Connection
1+1 Twin-path FD with Antenna Direct Connection
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-3
Fig. 2-1 Protected/Unprotected System Configuration (2/3)
ODU (Working) IDU
DATA1
IN/OUT
ODU (Working)
IDU DATA2
IN/OUT
IDU
X IF Cable
1+0 IDU
IF Cable
IF Cable
1+0 IDU
V (H)
H (V)
H (V)
ODU (Working)
OMT
IDU
DATA1
IN/OUT
ODU (Working)
IDU
DATA2
IN/OUT
IDU
X IF Cable
1+0 IDU
IF Cable
IF Cable
1+0 IDU
V (H)
H (V)
ODU (Working)
OMT
IDU
DATA1
IN/OUT
ODU (Working)
IDU DATA2
IN/OUT
IDU
X IF Cable
1+0 IDU
IF Cable
IF Cable
1+0 IDU
V (H)
H (V)
ODU (Working)
HYB
No.1
DATA1
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
No.2
ODU (Working)
HYB
No.1
DATA2
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
No.2
IDU
X IF Cable
IDU XPIC
CTRL
Cable
No. 1
No. 2
No. 1
No. 2
H (V)
V (H)
V (H)
H (V)
ODU (Working)
OMT
IDU
DATA1
IN/OUT
ODU (Working)
IDU DATA2
IN/OUT
IDU
X IF Cable
1+0 IDU
IF Cable
IF Cable
1+0 IDU
V (H)
H (V)
ODU (Working)
OMT
IDU
DATA1
IN/OUT
ODU (Working)
IDU DATA2
IN/OUT
IDU
X IF Cable
1+0 IDU
IF Cable
IF Cable
1+0 IDU
V (H)
H (V)
RF Cable
ODU (Working) IDU
DATA1
IN/OUT
ODU (Working)
IDU DATA2
IN/OUT
IDU
X IF Cable
1+0 IDU
IF Cable
IF Cable
1+0 IDU
V (H)
H (V)
RF Cable
2(1+0) XPIC with Antenna Direct Connection
2(1+0) XPIC with Waveguide/Coaxial Cable Connection
2(1+0) XPIC with Waveguide/Coaxial Cable Connection
2(1+1) XPIC with Waveguide/Coaxial Cable Connection
ODU (Working)
HYB
No.1
DATA1
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
No.2
ODU (Working)
HYB
No.1
DATA2
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
No.2
IDU
X IF Cable
IDU XPIC
CTRL
Cable
No. 1
No. 2
No. 1
No. 2
H (V)
V (H)
V (H)
H (V)
IDU XPIC
CTRL
Cable
IDU XPIC
CTRL
Cable
IDU XPIC
CTRL
Cable
IDU XPIC
CTRL
Cable
IDU XPIC
CTRL
Cable
IDU XPIC
CTRL
Cable
f1
f1
f1
f1
f1
f1
f1
f1
f1
f1
f1
f1
f1
f1
f1
f1
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-4
Fig. 2-1 Protected/Unprotected System Configuration (3/3)
IF
Cable
ODU
IDU
E1/LAN
DATA
IN/OUT
IDU
2-WAY/Cross-conect (XC) Configuration
ODU
MODEM (No.1)
16E1 INTFC
2-WAY/XC PKG
(e/w LAN)
MODEM (No.2)
E1/LAN
DATA
IN/OUT
IF
Cable
ODU
IF
Cable
IF
Cable
ODU
IDU
E1/LAN
DATA
IN/OUT
DIR-A DIR-B
Tributary
(2-WAY/XC System)
For the details description, refer to APPENDIX 2-WAY/XC Application and Setting.
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-5
Fig. 2-2 Signal Interface/Capacity (1/2)
ODU
IDU
16E1 (0 to 16 2 MB G.703 +80 to 8 MB 10/100 Base T(x)
IEEE 802.3)
MAIN DATA INTFC (Selectable)
48E1 (5/10/20/40/48 2 MB) G.703
STM-1 (155 MB ELE) G.703
16E1 (5/10/16 2 MB) G.703
STM-1 (155 MB OPT) G.957, S-1.1/L-1.1
SC (2 64 KB V.11 +2 9.6 KB RS-232C) +
EOW (1)
1000 Base T/SX IEEE 802.3z
6 to 52 GHz
128QAM
QPSK/16/32/128QAM
E3 (1/2 34 MB +4/8 2 MB) G.703
QPSK/16QAM/32QAM
ALM/HK/SC (AUX) INTFC
6 ALM OUT (4 HK OUT/4 Cluster OUT)
QPSK/16/32/128QAM
6 HK IN/4 Cluster IN
QPSK/16/32/128QAM
10/100 Base T(X) 2-Port LAN IEEE802.3
WS (1 2 MB) +64/128/192/256 KB SC- LAN 128QAM
WS/LAN INTFC (Additional)
STM-1 (155 MB OPT) ITU-T G.957, S-1.1/L-1.1
128QAM
MAIN DATA INTFC (for APS)
QPSK/16QAM
1+0/1+1 Configuration
32QAM
10/100 Base T(X) 4-Port LAN (100 MB) IEEE802.3 +
4E1 (4 2 MB) G.703
10/100 Base T(x) 4-Port LAN IEEE802.3 +8E1 (8 2 MB)
32E1 (0 to 32 2 MB G.703 +100 to 16 MB 10/100 Base T(x)
IEEE 802.3)
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-6
Fig. 2-2 Signal Interface/Capacity (2/2)
ODU
ODU
6 to 52 GHz
OMT
STM-1 (155 MB ELE) G.703
STM-1 (155 MB OPT) G.957, S-1.1/L-1.1
SC (2 64 KB V.11 +2 9.6 KB RS-232C) +
EOW (1 )
1000 Base T/SX IEEE 802.3z
128QAM
ALM/HK/SC(AUX)
6 ALM OUT (4 HK OUT/4 Cluster OUT)
6 HK IN/4 Cluster IN
10/100 Base T(X) 2-Port LAN IEEE 802.3
WS (1 2 MB) +64/128/192/256 KB SC- LAN
WS/SC-LAN INTFC (Additional)
STM-1 (155 MB OPT) G.957, S-1.1/L-1.1
MAIN DATA INTFC (for APS)
MAIN DATA INTFC (Selectable)
STM-1 (155 MB ELE) G.703
STM-1 (155 MB OPT) G.957, S-1.1/L-1.1
SC (2 64 KB V.11 +2 64 KB RS-232C) +
EOW (1)
1000 Base T/SX IEEE 802.3z
128QAM
ALM/HK/SC(AUX)
6 ALM OUT (4 HK OUT/4 Cluster OUT)
6 HK IN/4 Cluster IN
10/100 Base T(X) 2-Port LAN
WS (1 2 MB) +64/128/192/256 KB SC- LAN
WS/SC-LAN INTFC (Additional)
STM-1 (155 MB OPT) G.957, S-1.1/L-1.1
MAIN DATA INTFC (for APS)
MAIN DATA INTFC (Selectable)
No.2
No.1
IDU
IDU
XPIC Configuration
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-7
Fig. 2-3 IDU e/w Standard and Optional Interface (1/3)
Unprotected System (IDU)
SELV
!
STM-1 IN STM-1 OUT
AUX/ALM NMS NE
ALM
SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PULL
PWR
PASOLINK NEO
SELV
!
100M
AUX/ALM LCT NMS NE SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PASOLINK NEO
PORT 1 PORT 2 100M
ALM
2MIN/OUT-A 2MIN/OUT-B
SELV
!
AUX/ALM NMS NE SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PASOLINK NEO
ALM
2MIN/OUT-C
LCT
LCT
SELV
!
AUX/ALM NMS NE
ALM
SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PASOLINK NEO
LCT
2MIN/OUT-A 2MIN/OUT-B
STM-1 IN STM-1 OUT
PULL
PULL
PULL
Equipped with STM-1 Electrical Interface
Equipped with STM-1 Optical Interface for APS
Equipped with 16E1 Interface with 2 Port LAN Interface
Equipped with 48E1 Interface
SELV
!
STM-1 IN STM-1 OUT
AUX/ALM NMS NE
ALM
SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PULL
PWR
PASOLINK NEO
LCT
Equipped with STM-1 Electrical Interface in XPIC
SELV
!
STM-1 IN STM-1 OUT
AUX/ALM NMS NE
ALM
SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PULL
PWR
PASOLINK NEO
LCT
ALM
STM-1 IN STM-1 OUT
(Blank)
(Blank)
(Blank)
(Blank)
(Blank)
(Blank)
(Blank)
(Blank)
SELV
!
AUX/ALM NMS NE SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PULL
PWR
PASOLINK NEO
LCT
Equipped with DC-DC CONV
SELV
PWR PULL
PWR
ALM
FUSE (250V/8AH)
43V
G
OUT
ONLINE
ONLINE
(Blank)
G
G
G
G
G
G
G
G
G
G
G
G
G
G
STD
G
G
G
G
G
G
G
G
SELV
!
AUX/ALM NMS NE SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PASOLINK NEO
ALM
LCT
PULL
Equipped with E3 Interface
(Blank)
G
G
G
100M PORT 1 PORT 2 100M
WS IN/OUT IN OUT
E3 CH1
IN OUT
E3 CH2
STM-1 IN STM-1 OUT
ALM (Blank)
SELV
!
100M
AUX/ALM LCT NMS NE SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PASOLINK NEO
PORT 1 PORT 2 100M
ALM
2MIN/OUT-A 2MIN/OUT-B
PULL
Equipped with 32E1 Interface with 2 Port LAN Interface
(Blank)
G
G
G
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-8
Fig. 2-3 IDU e/w Standard and Optional Interface (2/3)
Protected System (IDU)
SELV
!
STM-1 IN STM-1 OUT
AUX/ALM NMS NE
ALM
SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PULL
PWR
PASOLINK NEO
SELV
!
100M
AUX/ALM LCT NMS NE SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PASOLINK NEO
PORT 1 PORT 2 100M
ALM
2MIN/OUT-A 2MIN/OUT-B
SELV
!
AUX/ALM NMS NE SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PASOLINK NEO
ALM
2MIN/OUT-C
LCT
LCT
SELV
!
AUX/ALM NMS NE
ALM
SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PASOLINK NEO
LCT
2MIN/OUT-A 2MIN/OUT-B
STM-1 OUT STM-1 IN
PULL
PULL
PULL
Equipped with STM-1 Electrical Interface
Equipped with STM-1 Optical Interface in APS
Equipped with 16E1 Interface with 2 Port LAN Interface
Equipped with 48E1 Interface
SELV
!
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PULL
SELV
!
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PULL
SELV
!
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PULL
SELV
!
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PULL
SELV
!
STM-1 IN STM-1 OUT
AUX/ALM NMS NE
ALM
SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PULL
PWR
PASOLINK NEO
LCT
Equipped with STM-1 Electrical Interface in XPIC
SELV
!
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PULL
SELV
!
STM-1 IN STM-1 OUT
AUX/ALM NMS NE
ALM
SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PULL
PWR
PASOLINK NEO
LCT
SELV
!
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PULL
ALM
STM-1 OUT STM-1 IN
(Blank)
(Blank)
(Blank)
ONLINE ONLINE
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
SELV
!
AUX/ALM NMS NE SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PASOLINK NEO
ALM
LCT
PULL
Equipped with E3 Interface
G
G
G
100M PORT 1 PORT 2 100M
WS IN/OUT IN OUT
E3 CH1
IN OUT
E3 CH2
SELV
!
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PULL G
SELV
!
100M
AUX/ALM LCT NMS NE SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PASOLINK NEO
PORT 1 PORT 2 100M
ALM
2MIN/OUT-A 2MIN/OUT-B
PULL
Equipped with 32E1 Interface with 2 Port LAN Interface
SELV
!
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PULL
G
G
G
G
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-9
Fig. 2-3 IDU e/w Standard and Optional Interface (3/3)
SELV
!
AUX/ALM NMS NE SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PULL
PWR
PASOLINK NEO
LCT
SELV
!
AUX/ALM NMS NE SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PASOLINK NEO
LCT
PULL
Equipped with STM-1 Optical Interface with LAN/WS Interface (SDH)
Equipped with GbE Interface with LAN/WS Interface (SDH)
G
G
G
G
G
G
ALM
WS IN/OUT
100M PORT 1 PORT 2 100M
WS ALM
STM-1 OUT STM-1 IN
ONLINE
ALM
WS IN/OUT
100M PORT 1 PORT 2 100M
WS ALM
OUT
1000BASE-SX/LX
PORT IN
(Blank)
(Blank)
SELV
!
AUX/ALM NMS NE SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PASOLINK NEO
ALM
LCT
PULL
Equipped with 4P LAN Interface (PDH)
(Blank)
G
G
G
100M PORT 3 PORT4 100M
2M IN/OUT
100M PORT 1 PORT 2 100M
SELV
!
100M
AUX/ALM LCT NMS NE SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PASOLINK NEO
PORT 1 PORT 2 100M
ALM
2MIN/OUT-A 2MIN/OUT-B
PULL
SELV
!
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL PWR
PULL
G
G
G
G
Equipped with 16E1 Interface with 2 Port LAN for 2-WAY/XC (PDH)
2-WAY
SELV
!
AUX/ALM NMS NE SC IN/OUT EOW
PROTECT
CALL MMC
MAINT
MEMORY
IDU
XIF IN XIF OUT
IF IN/OUT
TX
RX
RESET XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PULL
PWR
PASOLINK NEO
LCT
Equipped with LAN/WS Interface for Main LAN (SDH)
G
G
ALM
WS IN/OUT
100M PORT 1 PORT 2 100M
WS
(Blank)
MS .
G
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-10
Fig. 2-4 Configuration of the ODU (1/4)
Waveguide Connection (1+0)
(11-38 GHz NHG)
ODU
Coaxial Cable Connection 6/7/8GHz (1+0)
ODU


Antenna
Antenna Direct Mounting (1+0)
(11-52 GHz NHG)
ODU
Antenna Direct Mounting (1+0)
(13-38 GHz NHG2)
ODU
Waveguide Connection (1+0)
(13-38 GHz NHG2)
ODU
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-11
Fig. 2-5 Configuration of the ODU (2/4)
Antenna Direct Mounting 2(1+0)
(ODU NHG Type)
ODU
OMT
Coaxial Cable Connection 6/7/8GHz 2(1+0)
(ODU NHG or NHG2 Type)
ODU
OMT
Dual Pol. Antenna
Dual Pol. Antenna
Dual Pol. Antenna
Antenna Direct Mounting 2(1+0)
(ODU NHG2 Type)
OMT
Waveguide Connection 2(1+0)
(ODU
ODU
Dual Pol. Antenna
Dual Pol. Antenna
ODU
Waveguide Connection 2(1+0)
(ODU NHG2 Type)
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-12
Fig. 2-5 Configuration of the ODU (3/4)
Waveguide Connection (1+1 SD)
ODU
ODU
Antenna Direct Mounting (1+1)
(ODU NHG Type)
ODU
HYB
Coaxial Cable Connection 6/7/8 GHz (1+1)
ODU
HYB
Antenna Direct Mounting (1+1)
(ODU NHG2 Type)
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-13
Fig. 2-5 Configuration of the ODU (4/4)
Waveguide Connection 2(1+1) XPIC
(ODU NHG Type)
ODU
ODU
ODU
ODU
Dual Pol. Antenna
Dual Pol. Antenna
(REG)
(PROT)
Waveguide Connection 2(1+1) XPIC
(ODU NHG2 Type)
Dual Pol. Antenna
ODU
Dual Pol. Antenna
ODU
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-14
Fig. 2-6 System Block Diagram (1/5)
IN/OUT
( )INTFC *
CTRL
NMS
LCT
EOW
MODEM
DC-DC
CONV
RF
PS
CKT
SYNTH
(LO)
CTRL
IDU ODU
48E1/
1/2E3
ALM IN/OUT
BPF
(TX)
BPF
(RX)
ODU
INTFC
ODU
INTFC
DPU/
FEC
SC IN/OUT
NE
IN/OUT
STM-1 (ELE)/
( )INTFC *1
CTRL NMS
LCT
EOW
MODEM
DC-DC
CONV
LAN/WS INTFC *3 WS/SC-LAN
RF
PS
CKT
SYNTH
(LO)
CTRL
IDU ODU
ALM IN/OUT
STM-1 (OPT)/
BPF
(TX)
BPF
(RX)
ODU
INTFC
ODU
INTFC
DPU/
FEC
SC IN/OUT
NE
128QAM
MODEM
1+0 CONFIGURATION FOR PDH
STM-1 (OPT)
1+0 CONFIGURATION FOR SDH
2-PORT LAN/WS
f
H(L)
f
L(H)
f
H(L)
f
L(H)
6 to 52 GHz
6 to 52 GHz
QPSK/
16QAM/
32QAM/
MODEM
16E1+2PORT LAN/
GbE
EOW
(J ACK)
EOW
(J ACK)
EOW
(J ACK)
LPF/EQL
LPF/EQL
PS IN
PS IN
Note: * Optional
Notes: *1 :Optional
*2:Provides for APS
*3:Provides for auxiliary signals
( )INTFC *2
32E1+2PORT LAN/
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-15
Fig. 2-6 System Block Diagram (2/5)
IN/OUT
( )INTFC *
CTRL NMS
LCT
EOW
MODEM
DC-DC
CONV
RF
PS
CKT
SYNTH
(LO)
CTRL
IDU ODU
EOW
48E1/
1/2E3
ALM IN/OUT
BPF
(TX)
BPF
(RX)
ODU
INTFC
ODU
INTFC
DPU/
FEC
SC IN/OUT
NE
1+1 CONFIGURATION FOR PDH
QPSK/
16QAM/
32QAM/
MODEM
16E1+2PORT LAN/
RF
PS
CKT
SYNTH
(LO)
CTRL
ODU
BPF
(TX)
BPF
(RX)
ODU
INTFC
(J ACK)
f
H(L)
f
L(H)
6 to 52 GHz
HYB
MODEM
DC-DC
CONV
ODU
INTFC
DPU/
FEC
MODEM
QPSK/
16QAM/
32QAM/
LPF/EQL
LPF/EQL
PS IN
PS IN
Note: * :Optional
32E1+2PORT LAN/
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-16
Fig. 2-6 System Block Diagram (3/5)
RF
PS
CKT
SYNTH
(LO)
CTRL
ODU
BPF
(TX)
BPF
(RX)
ODU
INTFC
RF
PS
CKT
SYNTH
(LO)
CTRL
ODU
BPF
(TX)
BPF
(RX)
ODU
INTFC
f
H(L)
f
L(H)
6 to 52 GHz
HYB
IN/OUT
STM-1 (ELE)/
( )INTFC *1
CTRL NMS
LCT
EOW
MODEM
DC-DC
CONV
LAN/WS INTFC *3 WS/SC-LAN
IDU
ALM IN/OUT
STM-1 (OPT)/
ODU
INTFC
DPU/
FEC
SC IN/OUT
NE
128QAM/
MODEM
( )INTFC *2
STM-1 (OPT)
2-PORT LAN/WS
GbE
EOW
(J ACK)
MODEM
DC-DC
CONV
ODU
INTFC
DPU/
FEC
MODEM
128QAM/
1+1 CONFIGURATION FOR SDH
LPF/EQL
LPF/EQL
PS IN
PS IN
Notes: *1 :Optional
*2:Provides for APS
*3:Provides for auxiliary signals
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-17
Fig. 2-6 System Block Diagram (4/5)
RF
PS
CKT
SYNTH
(LO)
CTRL
ODU
BPF
(TX)
BPF
(RX)
ODU
INTFC
1+0 CONFIGURATION FOR XPIC SDH
RF
PS
CKT
SYNTH
(LO)
CTRL
ODU
BPF
(TX)
BPF
(RX)
ODU
INTFC
f
H(L)
f
L(H)
6 to 52 GHz
OMT
IN/OUT
STM-1 (ELE)/
( )INTFC *1
CTRL NMS
LCT
EOW
MODEM
DC-DC
CONV
LAN/WS INTFC *3 WS/SC-LAN
IDU
ALM IN/OUT
STM-1 (OPT)/
ODU
INTFC
DPU/
FEC
SC IN/OUT
NE
128QAM/
MODEM
( )INTFC *2
STM-1 (OPT)
2-PORT LAN/WS
GbE
EOW
(J ACK)
MODEM
DC-DC
CONV
ODU
INTFC
DPU/
FEC
MODEM
128QAM/
H(V)
V(H)
V(H)
H(V)
IN/OUT
STM-1 (ELE)/
( )INTFC *1
CTRL NMS
LCT
EOW
LAN/WS INTFC *3 WS/SC-LAN
ALM IN/OUT
STM-1 (OPT)/
SC IN/OUT
NE
( )INTFC *2
STM-1 (OPT)
2-PORT LAN/WS
GbE
EOW
(J ACK)
IDU
LPF/EQL
LPF/EQL
PS IN
PS IN
Notes: *1 :Optional
*2:Provides for APS
*3:Provides for auxiliary signals
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-18
Fig. 2-6 System Block Diagram (5/5)
IN/OUT
16E1 INTFC *
CTRL NMS
LCT
EOW
No.1 MODEM (DIR-A)
DC-DC
CONV
RF
PS
CKT
SYNTH
(LO)
CTRL
IDU ODU (DIR-A)
EOW
ALM IN/OUT
BPF
(TX)
BPF
(RX)
ODU
INTFC
ODU
INTFC
DPU/
FEC
SC IN/OUT
NE
2-WAY CONFIGURATION FOR PDH
QPSK/
16QAM
MODEM 16E1+2PORT LAN
RF
PS
CKT
SYNTH
(LO)
CTRL
ODU (DIR-B)
BPF
(TX)
BPF
(RX)
ODU
INTFC
(J ACK)
f
H(L)
f
L(H)
6 to 52 GHz
No.2 MODEM (DIR-B)
DC-DC
CONV
ODU
INTFC
DPU/
FEC
MODEM
QPSK/
16QAM
LPF/EQL
LPF/EQL
PS IN
PS IN
Note: * :Optional
f
H(L)
f
L(H)
6 to 52 GHz
DIR-A
DIR-B
TRIB
2-WAY/XC
PKG (e/w LAN)
XC
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-19
2.2 Performance Characteristics
2.2.1 General System
Table 2-1 System General Performance (1/2)
STANDARD (STD)
ITEM PDH LAN *2
Capacity Up to 100 Mbps
Interface D-sub 37: 16 E1/MDR68:32/ 48E1/
IEC 169-29(1.0/2.3): 1/2E3
RJ -45 (2/4 Ports):
10/100 Base-T(X)
Interconnecting Connector, Cable
impedance and Cable length
(IDU-ODU)
ODU side: N type female, 50 ohms (Coaxial)
IDU side: TNC type female, 50 ohms (Coaxial)
300m (in case 8D-FB cable or equivalent cable)
Channel Spacing
*1
QPSK 7 MHz, 14 (13.75) MHz, 28 (27.5) MHz
16 QAM 3.5 MHz, 7 MHz, 14 (13.75) MHz, 28 (27.5) MHz
32 QAM 28 (27.5) MHz
128 QAM Not Applicable
Environmental
Requirement
Guaranteed
Operation
ODU: 33 to +50C
IDU: 5 to +50C
Workable
Operation
ODU: 40 to +55C
IDU: 10 to +55C
Transportation/
Storage
ODU, IDU: 40 to +70C
Relative
humidity
ODU: 100% applicable
IDU: Less than 90% at +50C (Non-codensing)
EMC Conforms to EN301 489-4
Safety Conforms to EN60950
Power Requirement 48 VDC (40.5 to 57 VDC), Conforms to EN300 132-2
Power Consumption (Typical)
ODU/Unit 30 W (6 to 11 GHz), 23 W (13 to 52 GHz)
IDU Card/Unit
MODEM 10 W
48E1 INTFC (for 48 E1) 8 W
32E1 INTFC (for 32 E1) 8 W
16E1 INTFC (for 16 E1) 8 W
E3 INTFC 8 W
4P LAN INTFC 8 W
CTRL 7 W
Weight/Card MODEM: 0.5 kg, 48E1 INTFC (for 48 E1): 0.4 kg, 16E1 INTFC (for 16 E1): 0.4 kg,
32E1 INTFC (for 32 E1): 0.4 kg, E3 INTFC (for E3): 0.4 kg, CTRL: 0.4 kg,
4P INTFC (for 4 Port LAN): 0.4 kg
Mechanical
Dimension
ODU (NHG 6-52 GHz)/(NHG2 6/7/8 GHz) 237(W) 237(H) 101(D): Approx. 3.5 kg/Unit
(NHG2 13-38 GHz) 239(W) 247(H) 68(D): Approx. 3.0 kg/Unit
IDU 482(W) 44(H) 240(D): Approx.4 kg
Notes *1: 13.75 or 27.5 MHz is applied for 18 GHz.
*2: For 48E1 INTFC, the LAN is not applicable.
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-20
Table 2-1 System Performance Characteristics (2/2)
STANDARD (STD)
ITEM SDH LAN
Capacity 155 Mbps *2 Up to 150 Mbps
Interface Optical: LC
Electrical: IEC 169-29(1.0/2.3)
Up to 2 STM-1 *3
RJ -45 (2 Ports): 10/100 BASE-T(X)
RJ -45: 1000 BASE-T
LC: 1000 BASE-SX/LX
Interconnecting Connector, Cable
impedance and Cable length
(IDU-ODU)
ODU side: N type female, 50 ohms (Coaxial)
IDU side: TNC type female, 50 ohms (Coaxial)
300m (in case 8D-FB cable or equivalent cable)
Channel Spacing
*1
QPSK (PDH)
Not Applicable
16QAM (PDH)
32QAM (PDH)
128QAM 28 (27.5) MHz 28 (27.5) MHz
Environmental
Requirement
Guaranteed
Operation
ODU: 33 to +50C
IDU: 5 to +50C
Workable
Operation
ODU: 40 to +55C
IDU: 10 to +55C
Transportation/
Storage
ODU, IDU: 40 to +70C
Relative
humidity
ODU: 100% applicable
IDU: Less than 90% at +50C (Non-codensing)
EMC Conforms to EN301 489-4
Safety Conforms to EN60950
Power Requirement 48 VDC (40.5 to 57 VDC), Conforms to EN300 132-2
Power Consumption (Typical)
ODU/Unit 30 W (6 to 11GHz), 23 W (13 to 38 GHz)
IDU Card/Unit
MODEM 10 W
STM-1O INTFC 5 W -
STM-1E INTFC 5 W -
LAN/WS INTFC - 5 W
GbE INTFC - 5 W
CTRL 7 W
Weight/Card MODEM: 0.5 kg, STM-1O INTFC: 0.3 kg, STM-1E INTFC: 0.3 kg,
LAN/WS INTFC: 0.3 kg, CTRL: 0.4 kg , GbE INTFC: 0.3 kg
Mechanical
Dimension
ODU (NHG 6-52 GHz)/(NHG2 6/7/8 GHz) 237(W) 237(H) 101(D): Approx. 3.5 kg/Unit
(NHG2 13-38 GHz) 239(W) 247(H) 68(D): Approx. 3.0 kg/Unit
IDU 482(W) 44(H) 240(D): Approx.4 kg
Notes *1: 27.5 MHz is applied for 18 GHz.
*2: 25Mbps using 2 sets for XPIC
*3: 2 for APS configuration
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-21
2.2.2 LAN Interface (10/100 Base-T(X))
Type : 10 Base-T/100 Base-TX (Auto-sensing or fixed)
Port Number and Interface
: 2 (Each port is separated) RJ -45
Transmission Rate: Selectable and rest E1 channels
Flow control : Full duplex or Half duplex (Backpressure)
Forwarding Mode: Store-and-Forwarding
(This interface card work as a LAN Bridge and
compliant with IEEE802.3)
Note: In case of employing main traffic LAN interface, LAN ports and
E1 ports can be used at the same time. However, the numbers of
E1 port are limited depending on the selected LAN transmission
rate as shown in the following tables.
Note: There are three (3) types 2 Port LAN/WS INTFC as follows.
: Unavailable
: Available
Main: w/o STM-1
Sub: e/w STM-1
*1 : Mounting position is Slot1 (for Main).
*2: Mounting position is Slot2 (for Sub).
(1) 2 Port LAN with WS INTFC
Table 2-2 2 Port LAN 150 Mbps (128QAM)
LAN Setting
LAN Capacity
[Mbps]
Port 1 Port 2
P1 & P2 =150 M Best effort (separated) 150
P1 =75 M separated P2 =75 M separated 150
P1 =100 M separated P2 =50 M separated 150
P1 =100 M separated Disabled 100
Type
Function
Remarks
Main LAN *1 Sub LAN *2 E1 WS *2
A Exclusive Sub CH for WS/LAN
B Exclusive Sub CH for WS
C Either Slot for Main or Sub CH for WS/LAN
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-22
*1 LAN capacity can be set in 2 Mbps step. (P1 & P2 Shared mode)
*2 For the Star and Mixed mode in 2-WAY, P1 & P2 capacities are the same values with shared mode.
*1 LAN capacity can be set in 2 Mbps step. (P1 & P2 Shared mode)
*2 For the Star and Mixed mode in 2-WAY, P1 & P2 capacities are the same values with shared mode.
(2) 2 Port LAN with E1 INTFC
Table 2-3 2 Port LAN 80 Mbps (16QAM)
LAN Setting Capacity
Port 1 Port 2 LAN [Mbps] E1 [CHs]
P1 & P2 =80 M shared *1 80 0
P1 & P2=shared from 80M to 48M (2 Mbps step) (1 CH step)
P1 & P2 =48M shared 48 16
P1 =40M separated P2 =40M separated 80 0
P1 =30M separated P2 =30M separated 60 10
P1 =24M separated P2 =24M separated 48 16
Disabled Disabled 0 16
Table 2-4 2 Port LAN 40 Mbps (16QAM/QPSK)
LAN Setting Capacity
Port 1 Port 2 LAN [Mbps] E1 [CHs]
P1 & P2 =40 M shared *1 40 0
P1 & P2=shared from 40M to 8M (2 Mbps step) (1 CH step)
P1 & P2 =8M shared 8 16
P1 =20M separated P2 =20M separated 40 0
P1 =10M separated P2 =10M separated 20 10
P1 =4M separated P2 =4M separated 8 16
Disabled Disabled 0 16
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-23
*1 For the Star and Mixed mode in 2-WAY, P1 & P2 capacities are the same values with shared mode.
*1 For the Star and Mixed mode in 2-WAY, P1 & P2 capacities are the same values with shared mode.
*1 LAN capacity can be set in 2 Mbps step. (P1 & P2 Shared mode)
Table 2-5 2 Port LAN 20 Mbps (16QAM/QPSK)
LAN Setting Capacity
Port 1 Port 2 LAN [Mbps] E1 [CHs]
P1 & P2 =20M shared 20 0
P1 & P2=shared from 20M to 2M (2 Mbps step) (1 CH step)
P1 & P2 =2M shared 2 9
P1 =10M separated P2 =10M separated 20 0
Disabled Disabled 0 10
Table 2-6 2 Port LAN 10 Mbps (16QAM/QPSK)
LAN Setting Capacity
Port 1 Port 2 LAN [Mbps] E1 [CHs]
P1 & P2 =10M shared 10 0
P1 & P2 =shared from 10M to 2M (2 Mbps step) (1 CH step)
P1 & P2 =2M shared 2 4
Disabled Disabled 0 5
Table 2-7 2 Port LAN 100 Mbps (32QAM) for 2 port LAN Only
LAN Setting Capacity
Port 1 Port 2 LAN [Mbps] E1 [CHs]
P1 & P2 =100 M shared *1 100 0
P1 & P2=shared from 100M to 36M (2 Mbps step) (1 CH step)
P1 & P2 =36M shared 36 32
P1 =50M separated P2 =50M separated 100 0
P1 =40M separated P2 =40M separated 80 10
P1 =30M separated P2 =30M separated 60 20
P1 =20M separated P2 =20M separated 40 30
P1 =18M separated P2 =18M separated 36 32
Disabled Disabled 0 32
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-24
Note: * Total capacity: 108 Mbps.
(3) 4 Port LAN with E1 INTFC
Table 2-8 4 Port LAN 100 Mbps (32QAM)
LAN Setting Capacity *
Port 1 Port 2 Port 3 Port 4 LAN [Mbps] E1 [CHs]
P1 - P4 =100 M shared 100 4
P1 & P2=50M separated P3 & P4=50M separated 100 4
P1 =25M
separated
P2 =25M
separated
P3 =25M
separated
P4 =25M
separated
100 4
Disabled Disabled Disabled Disabled 0 4
Table 2-9 4 Port LAN 80 Mbps (16QAM)
LAN Setting Capacity
Port 1 Port 2 Port 3 Port 4 LAN [Mbps] E1 [CHs]
P1 - P4 = 80M shared 80 0
P1 - P4 =shared from 64M to 80M (2 Mbps step) (1 CH step)
P1 & P2=40M shared P3 & P4=40M shared 80 0
P1 & P2=32M shared P3 & P4=32M shared 64 8
P1 =20M
separated
P2 =20M
separated
P3 =20M
separated
P4 =20M
separated
80 0
P1 =16M
separated
P2 =16M
separated
P3 =16M
separated
P4 =16M
separated
64 8
Disabled Disabled Disabled Disabled 0 8
Table 2-10 4 Port LAN 40 Mbps (16QAM/QPSK)
LAN Setting Capacity
Port 1 Port 2 Port 3 Port 4 LAN [Mbps] E1 [CHs]
P1 - P4 =40M 40 0
P1 - P4 =shared from 24M to 40M (2 Mbps step) (1 CH step)
P1 & P2=20M shared P3 & P4=20M shared 40 0
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-25
2.2.3 LAN Interface (1000Base-SX/LX, 1000Base-T) (GbE)
P1 & P2=12M shared P3 & P4=12M shared 24 8
P1 =10M
separated
P2 =10M
separated
P3 =10M
separated
P4 =10M
separated
40 0
P1 =6M
separated
P2 =6M
separated
P3 =6M
separated
P4 =6M
separated
24 8
Disabled Disabled Disabled Disabled 0 8
Table 2-11 4 Port LAN 20 Mbps (16QAM/QPSK)
LAN Setting Capacity
Port 1 Port 2 Port 3 Port 4 LAN [Mbps] E1 [CHs]
P1 - P4 =20M shared 20 0
P1 - P4 =shared from 4M to 20M (2 Mbps step) (1 CH step)
P1 & P2=10M shared P3 & P4=10M shared 20 0
Disabled Disabled Disabled Disabled 0 8
Table 2-12 4 Port LAN 10 Mbps (16QAM/QPSK)
LAN Setting Capacity
Port 1 Port 2 Port 3 Port 4 LAN [Mbps] E1 [CHs]
P1 - P4 =10M shared 10 0
P1 - P4 =shared from 2M to 10M (2 Mbps step) (1 CH step)
Disabled Disabled Disabled Disabled 0 5
Table 2-13 GbE LAN
Type 1000 Base-SX/LX (IEEE 802.3z) 1000 Base-T (IEEE 802.3ab)
Throughput 150 Mbps 150 Mbps
Connector type LC RJ -45
Port Number 1 port 1 port
Table 2-10 4 Port LAN 40 Mbps (16QAM/QPSK)
LAN Setting Capacity
Port 1 Port 2 Port 3 Port 4 LAN [Mbps] E1 [CHs]
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-26
2.2.4 Service Channel (SC)
SC1 to SC4 : RS-232C, 9.6 kbps async.,
: V.11, 64 kbps (Contra/Co-directional: Selectable)
SC5 : EOW 1 channel
Connector : High Density D-sub 44 ways
LAN Interface : SC LAN Interface
(throughput: 64/128/256 kbps)
2.2.5 LCT (PNMT) Interface
Serial Interface : Connector type USB-B
2.2.6 PNMS Interface
10 Base T : Connector RJ -45
2.2.7 RF I/O Port
Interface Port Type:
Antenna direct mount interface:exclusive NEC flange (11-52 GHz)
is attached to the RF IN/OUT port in
standard
Coaxial cable interface : 6/7/8 GHz: N (Female)
Waveguide feeder interface* (Remote mount):
6 GHz: PDR70
7/8 GHz: PDR84
10/11 GHz: PDR100
13 GHz: PBR120 or PBR140
15 GHz: PBR140
18/23 GHz: PBR220
26 GHz: PBR260
28/32/38 GHz: PBR320
52 GHz: WRJ 500
Polarization : Field changeable (Vertical or Horizontal)
Note: For the ODU of waveguide connection type, waveguide flange
adapter is attached to the RF IN/OUT port of remote mount ODU
in standard.
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-27
2.2.8 Parallel Alarm Interface
Output port : Relay Contact (Form-C); 6 outputs max.
(assignable 4 outputs for multiple items)
Input port : Photo coupler; 6 items max.
Cluster ALM
IN/OUT : 4 items (max.)
(Up to four cluster alarms are provided. For each
cluster alarm IN corresponding cluster alarm OUT
should be assigned in the opposite station.
Connector : High Density D-sub 44 ways
2.2.9 Wayside
In case of 155 Mbps capacity, one (1) wayside channel can be used as E1
or LAN interface.
In case of 2E3 INTFC, eight (8) wayside channels can be used as E1 or
LAN interface.
In case of 1E3 INTFC, four (4) wayside channels can be used as E1 or
LAN interface.
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-28
2.2.10ODU (Outdoor Unit) and System performance
*1 13.75 MHz and 27.5 MHz are applied for 18 GHz.
*2 For the ODU of waveguide connection type, flange adapter
is attached to the RF IN/OUT port of remote mount ODU in
standard.
*3 Additional attenuation is unavailable.
Table 2-14 System Performance for QPSK/ODU
Frequency Band (GHz) 6 7-8 10-11 13 15 18 23 26 28 32 38 52 Guaranteed
Range [GHz] 5.925-
7.125
7.125-
8.5
10.15-
11.7
12.75-
13.25
14.2-
15.35
17.7-
19.7
21.2-
23.6
24.25-
26.5
27.5-
29.5
31.8-
33.4
37.0-
40.0
51.4-
52.6

Interface
type
Direct
Mount
PDR 70 PDR 84 NEC Original
Remote
mount
*2
N type
or
PDR 70
N type
or
PDR 84
PDR
100
PBR
120
PBR
140
PBR
220
PBR
220
PBR
260
PBR
320
PBR
320
PBR
320
N/A
Output Power, nominal
(dBm) (Measured at ODU
output port)
+29 +25 +25 +23 +24 +24 +22 +22 +22 +18 +3 6-28G:1.5 dB
32-52G:+1.5/2.5 dB
Power Control (1 dB step,
variable)
0 to 30 dB
*3
0 to 25 dB
*3
0 to 10 dB 1.0 dB
ATPC (1 dB step) 0 to 30 dB
*3
0 to 25 dB
*3
0 to 10 dB
Frequency Stability 6 ppm 10 ppm
Threshold Level (dBm), (Measured at ODU input port) at BER =10
-6
+3.0 dB
Channel Separation (CS)=
28 (27.5)
*1
MHz (40 Mbps)
84 83 83 83.5 83.5 83.5 83 83 81.5 81.5 78
14 (13.75)
*1
MHz
(20 Mbps)
87 86 86 86.5 86.5 86.5 86 86 84.5 84.5 81
7 MHz (10 Mbps) 90 89 89 89.5 89.5 89.5 89 89 87.5 87.5 84
BER =10
-3 Above value 1.5 dB
SystemGain (dB), (Measured at ODU input port) at BER =10
-6
6-26G:3.0 dB
28-52G:4.0 dB
Channel Separation (CS)=
28 (27.5)
*1
MHz
113 108 108 106.5 107.5 107.5 105 105 103.5 99.5 81
14 (13.75)
*1
MHz
116 111 111 109.5 110.5 110.5 108 108 106.5 102.5 84
7 MHz 119 114 114 112.5 113.5 113.5 111 111 109.5 105.5 87
BER =10
-3 Above value +1.5 dB
MaximumInput Level 15 dBm(No Error)
Residual BER Less than 10
-12
at RSL=30 dBm
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-29
*1 13.75 MHz and 27.5 MHz are applied for 18 GHz.
*2 For the ODU of waveguide connection type, flange adapter
is attached to the RF IN/OUT port of remote mount ODU in
standard.
*3 Additional attenuation is unavailable.
Table 2-15 System Performance for 16QAM/ODU
Frequency Band (GHz) 6 7-8 10-11 13 15 18 23 26 28 32 38 Guaranteed
Range [GHz] 5.925-
7.125
7.125-
8.5
10.15-
11.7
12.75-
13.25
14.2-
15.35
17.7-
19.7
21.2-
23.6
24.25-
26.5
27.5-
29.5
31.8-
33.4
37.0-
40.0

Interface
type
Direct
Mount
PDR 70 PDR 84 NEC Original
Remote
mount
*2
N type
or
PDR 70
N type
or
PDR 84
PDR
100
PBR
120
PBR
140
PBR
220
PBR
220
PBR
260
PBR
320
PBR
320
PBR
320

Output Power, nominal (dBm)


(Measured at ODU output port)
+27 +21.5 +22.5 +22.5 +22 +22 +20 +18 +17 +14.5 6-28G:1.5 dB
32-38G:+1.5/2.5 dB
Power Control (1 dB step,
variable)
0 to 24 dB
*3
1.0 dB
ATPC (1 dB step) 0 to 24 dB
*3

Frequency Stability 6 ppm 10 ppm


Threshold Level (dBm), (Measured at ODU input port) at BER =10
-6
+3.0 dB
Channel Separation (CS) =
28 (27.5)
*1
MHz
77 76 76 76.5 76.5 76.5 76 76 74.5 74.5
14 (13.75)
*1
MHz
80 79 79 79.5 79.5 79.5 79 79 77.5 77.5
7 MHz 83 82 82 82.5 82.5 82.5 82 82 80.5 80.5
3.5 MHz 86 85 85 85.5 85.5 85.5 85 85 83.5 83.5
BER =10
-3
Above value 1.5 dB
SystemGain (dB), (Measured at ODU input port) at BER =10
-6
3.0 dB
Channel Separation (CS)=
28 (27.5)
*1
MHz (80 Mbps)
104 97.5 98.5 99 98.5 98.5 96 94 91.5 89
14 (13.75)
*1
MHz (40 Mbps)
107 100.5 101.5 102 101.5 101.5 99 97 94.5 92
7 MHz (20 Mbps) 110 103.5 104.5 105 104.5 104.5 102 100 97.5 95
3.5 MHz (10 Mbps) 113 106.5 107.5 108 107.5 107.5 105 103 100.5 98
BER =10
-3
Above value +1.5 dB
MaximumInput Level 20 dBmfor the BER less than 10
-3

Residual BER Less than 10


-12
at RSL =30 dBm
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-30
*1 27.5 MHz is applied for 18 GHz.
*2 For the ODU of waveguide connection type, flange adapter
is attached to the RF IN/OUT port of remote mount ODU in
standard.
*3 Additional attenuation (5 dB maximum) is available.
*4 Additional attenuation is unavailable.
Table 2-16 System Performance for 32QAM/ODU
Frequency Band (GHz) 6 7-8 10-11 13 15 18 23 26 28 32 38 Guaranteed
Range [GHz] 5.925-
7.125
7.125-
8.5
10.15-
11.7
12.75-
13.25
14.2-
15.35
17.7-
19.7
21.2-
23.6
24.25-
26.5
27.5-
29.5
31.8-
33.4
37.0-
40.0

Interface
type
Direct
Mount
PDR 70 PDR 84 NEC Original
Remote
mount
*2
N type
or
PDR 70
N type
or
PDR 84
PDR
100
PBR
120
PBR
140
PBR
220
PBR
220
PBR
260
PBR
320
PBR
320
PBR
320

Output Power, nominal


(dBm) (Measured at ODU
output port)
+25 +21 +21 +21 +19 +19 +18 +18 +17 +14.5 6-28G:1.5 dB
32-38G:+1.5/2.5 dB
Power Control (1 dB step,
variable)
0 to 23 dB
*3
0 to 23 dB
*4 1.0 dB
ATPC (1 dB step) 0 to 23 dB
*4

Frequency Stability 6 ppm 10 ppm


Threshold Level (dBm), (Measured at ODU input port) at BER =10
-6
+3.0 dB
Channel Separation (CS)=
28 (27.5)
*1
MHz
75.5 74.5 74.5 75 75 75 74.5 74.5 73 73
BER =10
-3 Above value 1.5 dB
SystemGain (dB), (Measured at ODU input port) at BER =10
-6
3.0 dB
Channel Separation (CS)=
28 (27.5)
*1
MHz
100.5 100.5 95.5 95.5 96 94 94 92.5 92.5 90 87.5
BER =10
-3 Above value +1.5 dB
MaximumInput Level 20 dBmfor the BER less than 10
-3

Residual BER Less than 10


-12
at RSL=30 dBm
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-31
*1 27.5 MHz is applied for 18 GHz.
*2 For the ODU of waveguide connection type, flange adapter
is attached to the RF IN/OUT port in standard.
*3 Additional attenuation (5 dB maximum) is available.
*4 Additional attenuation is unavailable.
Note: XPIC system has the same condition as above.
Table 2-17 System Performance for 128QAM/ODU
Frequency Band (GHz) 6 7-8 10-11 13 15 18 23 26 28 32 38 Guaranteed
Range [GHz] 5.925-
7.125
7.125-
8.5
10.15-
11.7
12.75-
13.25
14.2-
15.35
17.7-
19.7
21.2-
23.6
24.25-
26.5
27.5-
29.5
31.8-
33.4
37.0-
40.0

Interface
type
Direct
Mount
PDR 70 PDR 84 NEC Original
Remote
mount
*2
N type
or
PDR 70
N type
or
PDR 84
PDR
100
PBR
120
PBR
140
PBR
220
PBR
220
PBR
260
PBR
320
PBR
320
PBR
320

Output Power, nominal


(dBm) (Measured at ODU
output port)
+25 +21 +21 +21 +19 +19 +18 +18 +17 +14.5 6-28G:1.5 dB
32-38G:+1.5/2.5 dB
Power Control (1 dB step,
variable)
0 to 20 dB
*3
0 to 20 dB
*4
1.0 dB
ATPC (1 dB step) 0 to 20 dB
*4
0 to 20 dB
*4

Frequency Stability 6 ppm 10 ppm


Threshold Level (dBm), (Measured at ODU input port) at BER =10
-6
+3.0 dB
Channel Separation (CS)=
28 (27.5)
*1
MHz
69.5 68.5 68.5 69 69 69 68.5 68.5 67 67
BER =10
-3 Above value 1.5 dB
SystemGain (dB), (Measured at ODU input port) at BER =10
-6
-3.0 dB
Channel Separation =
28 (27.5)
*1
MHz
94.5 89.5 89.5 90 88 88 86.5 86.5 84 81.5
BER =10
-3 Above value +1.5 dB
MaximumInput Level 20 dBmfor the BER less than 10
-3

Residual BER Less than 10


-12
at RSL=30 dBm
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-32
2.2.11IDU (Indoor Unit) and System performance
* This value is available with 2 IDUs per 1 RF CH with
XPIC system.
** This indicates the online status which is selected from
Working/Standby in APS system or Working in w/o APS
system.
Table 2-18 System Performance for IDU
No. Item
Specification
PDH SDH LAN
1 IDU type 1+0 Expandable/1+1
2 Modulation Type QPSK/16/32QAM 128QAM QPSK/16/32/128QAM
3 Baseband Interface E1:
2.048 Mbps 50 ppm
E3:
34.368 Mbps 20 ppm
155.52 Mbps 20 ppm 10/100 Base-T(X)
1000 Base-SX/LX
1000 Base-T
75 ohm/120 ohm 75 ohm 75 ohm/S-1.1/L-1.1
D-sub37/MDR68 IEC 169-29 (1.0/2.3) IEC 169-29 (1.0/2.3) RJ -45 (10/100/1000 Base-T(X))
LC (1000 Base-SX/LX)
Channel Number 5/10/16/20/32/40/48 1/2 1/2* 1/2
Total Capacity 10/20/32/40/80/96
Mbps
34/68 Mbps 155 Mbps 10/20/40/80/100/100+50,
75+75 Mbps
4 Service Channels V.11 (Contra/Co-directional) 2 channels, RS-232C 2 channels
5 EOW IDU-IDU
6 External alarm &
House keeping
See table below
7 Security level by LCT 2 levels
8 Control &Setting by
LCT/PNMT
Serial Interface (USB connector)
Loop Back a) Far End Baseband Loop Back
b) Near End Baseband Loop Back
c) IF Loop back
BER Alarm Adjustable 10
-3
/ 10
-4
/ 10
-5
(High BER) 10
-6
/ 10
-7
/ 10
-8
/ 10
-9
(Low BER)

Frequency setting Direct entry or Table Download entry: Available when using PNMx (optional)
TX output Control Manual control, Automatic control, Mute control
9 Performance
monitoring (PMON)
/Metering
PMON Items;
a) OFS, b) BBE, c) ES, d) SES, e) SEP, f) UAS
Metering Items
a) Output power level (TX PWR), b) Received signal level (AGC V) c) Bit error rate (BER MON)
LAN monitoring Items;
a) RX Unicast, b) RX Broadcast, c) RX Multicast, d) RX Pause, e) RX CRC error
10 LED Display CTRL IDU Alarm (Red)
Maintenance (Amber)
Memory Access (Amber)
MODEM Operating PWR (Green)
ODU Alarm (Red)
MD/CBL Alarm (Red)
TX status (Green)
RX status (Green)
XPIC Reset (Amber)*
PDH INTFC Module alarm (Red)
SDH INTFC Module alarm (Red)
Online (Green)**
LAN/WS INTFC Module alarm (Red)
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-33
Table 2-19 Alarm & House Keeping Output Items
#
Alarm Item
displayed
on LCT/PNMT
Condition
ALM LED
Indication
(IDUs front)
Summarized Alarm Output
(Form-C) <Note 3,4,5,10>
RL1 RL2 RL3 RL4 RL5 RL6
1 MAINT System under maintenance MAINT MASK MASK MASK MASK
2 IDU CPU ALM IDU CPU failure -
3 PS ALM1 PS1 failure (only1+1) PWR
4 PS ALM2 PS2 failure (only1+1) -
5 ODU ALM1 ODU1 total alarm ODU

6 ODU ALM2 ODU2 total alarm


7 ODU CPU/CBL
OPN ALM1
ODU1 CPU failure or IF cable is
open
ODU
Blinking

8 ODU CPU/CBL
OPN ALM2
ODU2 CPU failure or IF cable is
open

9 TX PWR ALM1 ODU1 output power decrease ODU


10 TX PWR ALM2 ODU2 output power decrease
11 TX INPUT ALM1 ODU1 TX IF input level decrease ODU
12 TX INPUT ALM2 ODU2 TX IF input level decrease
13 APC ALM1 ODU1 LO OSC APC loop out of
lock
ODU
14 APC ALM2 ODU2 LO OSC APC loop out of
lock
15 RX LEV ALM1 ODU1 Receiving level decrease ODU
16 RX LEV ALM2 ODU2 Receiving level decrease
17 IF CABLE SHORT
ALM1
IF Cable connected to ODU1 short IDU
MD/CBL
Blinking
18 IF CABLE SHORT
ALM2
IF Cable connected to ODU2 short
19 IDU ALM IDU total alarm IDU
20 MOD ALM1 MOD PLL APC loop out of lock,
MOD output level down or TX
DPU CLK loss in MODEM1
IDU
MD/CBL
21 MOD ALM2 MOD PLL APC loop out of lock,
MOD output level down or TX
DPU CLK loss in MODEM2
22 DEM ALM1 Carrier Asynchronous,
Frame Asynchronous at DPU in
MODEM1
IDU
MD/CBL
23 DEM ALM2 Carrier Asynchronous,
Frame Asynchronous at DPU in
MODEM2
24 HIGH BER ALM1 BER >10E-3 to -5 (selectable) in
MODEM1
IDU
MD/CBL

25 HIGH BER ALM2 BER >10E-3 to -5 (selectable) in


MODEM2

26 LOW BER ALM1 BER >10E-6 to -9 (selectable) in


MODEM1
IDU
MD/CBL
27 LOW BER ALM2 BER >10E-6 to -9 (selectable) in
MODEM2
28 LOF1 Loss of Radio frame
synchronization in MODEM1
IDU
MD/CBL
29 LOF2 Loss of Radio frame
synchronization in MODEM2
30 INPUT LOSS
CH 1-48
Loss of input data stream
from DTE <Note 1>
IDU INTFC
<Note7>
31 AIS RCVD
CH 1-48
AIS (all 1) is received
from DTE <Note 1>
IDU INTFC
<Note7>
32 AIS GENERATED
CH 1-48
AIS (all 1) is sent to
DTE <Note 1>
IDU INTFC
<Note7>
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-34
Note 1: Apply to each channel of E1/E3.
Note 2: Unused channel/interface is masked according to the bit rate.
Note 3: It is possible to change capacity between E1 and Ethernet under working
condition.
Note 4: In MAINT status, excepting HK-OUT and Cluster ALM, alarm outputs are masked
to normal condition.
Note 5: The summarization of alarm outputs is fully user programmable; The sign in
above table shows fixed item and can not be changed. The sign only shows the
factory settings. The sign output can be assigned for plural items. The sign
input/output can not be assigned. Either HK output or Cluster ALM output
in each channel can be assigned.
Note 6: Above Table shows Alarm output matrix for 1+1 configuration
Note 7: Only apply to PDH system.
Note 8: Only apply to SDH system.
Note 9: Only apply to XPIC system.
Note 10:Assign to relays 3 to 6 only one category, either Pasolink Alarm, House Keeping
Control out or Cluster Alarm out.
Note 11:In the 2-WAY mode,
DIR-A: Cluster ALM out 3(RL4) and Cluster ALM out 4(RL3)
DIR-B: Cluster ALM out 1(RL6) and Cluster ALM out 2(RL5)
33 CH USAGE ERROR
CH 1-48
Use of a channel set as not used
(E1 channel) <Note 2>
IDU INTFC
<Note7>
34 LAN LINK PORT
1-4
Loss of Main LAN Link <Note 3> IDU INTFC
<Note7>
35 STM-1(1/2) LOS
(MUX)
Loss of input data stream
from MUX <Note 3>
IDU INTFC
<Note8>
36 STM-1(1/2) LOS
(DMR)
Loss of input data stream
from DMR <Note 3>
IDU INTFC
<Note8>
37 STM-1(1/2) TF
ALM
Loss of STM-1 signal output to
MUX <Note 3>
IDU INTFC
<Note8>
38 WS INPUT LOSS Loss of Wayside signal input IDU INTFC
<Note8>
39 INTFC (1/2) LAN
LINK PORT
Loss of SC LAN Link IDU INTFC
<Note8>
40 XCTRL ALM1 Control failure or REF
Signal failure
IDU INTFC
<Note9>
41 XCTRL ALM2 Control failure or REF
Signal failure
IDU INTFC
<Note9>
42 XREF ALM1 Control failure or REF
Signal failure
IDU INTFC
<Note9>
43 XREF ALM2 Control failure or REF
Signal failure
IDU INTFC
<Note9>
44 HK-OUT1 House keeping Control out1 Only show
PNMT
45 HK-OUT2 House keeping Control out2 Only show
PNMT
46 HK-OUT3 House keeping Control out3 Only show
PNMT
47 HK-OUT4 House keeping Control out4 Only show
PNMT
48 Cluster ALM out1
This item received from
opposite site. Item 1
Only show
PNMT
49 Cluster ALM out2
This item received from
opposite site. Item 2
Only show
PNMT
50 Cluster ALM out3
This item received from
opposite site. Item 3
Only show
PNMT
51 Cluster ALM out4
This item received from
opposite site. Item 4
Only show
PNMT
Table 2-19 Alarm & House Keeping Output Items (Contd)
#
Alarm Item
displayed
on LCT/PNMT
Condition
ALM LED
Indication
(IDUs front)
Summarized Alarm Output
(Form-C) <Note 3,4,5,10>
RL1 RL2 RL3 RL4 RL5 RL6
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-35

Note 1: Unused channel/interface is masked according to the bit rate.
Note 2: In the 2-WAY mode, Cluster ALM is transmitted in parallel for DIR-A and DIR-B.
Table 2-20 House keeping input Items
#
House keeping Item
displayed
on LCT/PNMT
Condition Event Indication
Summarized Alarm Input
(Photo coupler)
IN1 IN2 IN3 IN4 IN5 IN6
1 HK-IN1 House keeping Event inport1 Only show PNMT
2 HK-IN2 House keeping Event inport2 Only show PNMT
3 HK-IN3 House keeping Event inport3 Only show PNMT
4 HK-IN4 House keeping Event inport4 Only show PNMT
5 HK-IN5 House keeping Event inport5 Only show PNMT
6 HK-IN6 House keeping Event inport6 Only show PNMT
7 Cluster ALM input1 This item transmits to opposite site. Item 1 Only show PNMT
8 Cluster ALM input2 This item transmits to opposite site. Item 2 Only show PNMT
9 Cluster ALM input3 This item transmits to opposite site. Item 3 Only show PNMT
10 Cluster ALM input4 This item transmits to opposite site. Item 4 Only show PNMT
Output Port condition
Interface circuit: Relay Form C
Maximum Current: 0.2 A
Maximum Voltage: 100 V (AC+DC)
Event/ Alarm Open
(Normally closed)
Event/ Alarm Close
(Normally open)
COM
Relay
Normally Open
Control Closed
+3.3 V +3.3 V
Input Port condition
Normal OPEN (> 200 k ohms)
Control CLOSE (< 50 ohms)
Interface circuit: photo coupler with bias circuit
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-36
2.3 Interconnection between ODU and IDU
Note 1 : In case of employing hitless protection, set each length
of two IF cables same or the difference of their cable
length shall be less than 100 meters.
Note 2 : Salt damage (custom order)
In case of operating in the sea or around the coast area
(within 3 km from coastline), measure must be taken for
the ODU against salt damage. Please contact NEC for
the countermeasure.
Note 3 : Water Proof N type connector
The waterproof N type connectors must be used for IF
cable of ODU side, because DC voltage power is
supplied in it.
Note 4 : IDU IF connector = TNC (Female),
ODU IF connector = N (Female)
Note 5 : TNC (Male) L-angle connector for the 8D-FB IF cable
is used to connect it to the IDU. When the N (Male)
straight connector is attached to the 5D-FB or 10D-FB
IF cable, the TNC (Male) - N (Female) L-angle adapter
is used.
Table 2-21 IF Cable
No. Item Specification
1 Interconnection Single coaxial cable /50 ohms
2 Standard Type of Cable 5D-FB, 8D-FB (standard), 10D-FB
3 Signals IF signal, alarms, control, monitoring and power source
4 Maximum Cable Length 150 m (5D-FB)
300 m (8D-FB)
350 m (10D-FB)
5 Cable Equalization Automatic level equalization
6 Guaranteed temperature range 33C to +50C (workable : 40C to +55C)
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-37
2.4 Hybrid Combiner/Divider
There are two types of hybrid combiner/divider used in 1+1 protected
systems, one is coaxial cable connection type for 6/7/8 GHz Bands and the
other is ODU Direct Mount type for 11 - 52 GHz Bands. The following
NEC Hybrid Combiner/Divider is suited for Andrew or RFS Antenna, and
all NEC ODUs.
Fig. 2-7 Hybrid
* Custom ordered for 28 GHz.
6/7/8 GHz Hybrid 11 - 52 GHz Hybrid
Table 2-22 Characteristics
Frequency
Band
[GHz]
Frequency
Range
[GHz]
1-2 PORT
Variation
Max.(dB)
Loss Max.
(dB)
Isolation
Min.(dB)
VSWR Max. Interface
(ANT Side) (ODU Side)
L6 5.925 - 6.425 0.5 3.7 20 1.3 UDR70 N Connector
U6 6.43 - 7.11 0.5 3.7 20 1.3 UDR70 N Connector
7 7.125 - 7.9 0.5 3.7 20 1.3 UDR84 N Connector
8 7.7 - 8.5 0.5 3.7 20 1.3 UDR84 N Connector
11 10.5 - 11.7 0.5 3.5 20 1.2
NEC
original
NEC
original
13 12.75 - 13.25 0.5 3.5 20 1.2
15 14.5 - 15.35 0.5 3.5 20 1.2
18 17.7 - 19.7 0.5 3.5 20 1.2
23 21.2 - 23.6 0.5 3.5 20 1.2
26 24.5 - 26.5 0.5 3.8 20 1.2
32 31.8 - 33.4 0.5 3.8 20 1.2
38 37 - 39.5 0.5 3.8 20 1.2
52 51.4 - 52.6 0.5 4.5 20 1.3
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-38
2.4.1 10 dB Coupler
There are two types of NEC 10 dB Coupler; one is coaxial cable
connection type for 6/7/8 GHz bands and the other is ODU Direct Mount
type for 11 - 38 GHz Bands. The following 10 dB Coupler is suited for
Andrew or RFS Antenna, and all NEC ODUs.
Fig. 2-8 10 dB Coupler
* ODU for 6/7/8 GHz: Separate Type
* ODU for 11 - 38 GHz: Direct Mount Type
* Custom ordered for 28 GHz.
Table 2-23 Characteristics
Frequency
Band
[GHz]
Frequency
Range
[GHz]
1-2 PORT
Variation
Max.(dB)
Loss Max.
(dB)
Isolation
Min.(dB)
VSWR Max.
Interface
(ANT Side) (ODU Side)
L6/U6 5.925 - 7.125 0.5 1.2 20 1.3 UDR70 N Connector
7/8 7.125 - 8.5 0.5 1.2 20 1.3 UDR84 N Connector
11 10.5 - 11.7 0.5 1.2 20 1.2
NEC original NEC original
13 12.75 - 13.25 0.5 1.2 20 1.2
15 14.5 - 15.35 0.5 1.2 20 1.2
18 17.7 - 19.7 0.5 1.2 20 1.2
23 21.2 - 23.6 0.5 1.2 20 1.2
26 24.5 - 26.5 0.5 1.2 20 1.2
32 31.8 - 33.4 0.5 1.2 20 1.2
38 37 - 39.5 0.5 1.2 20 1.2
6/7/8 GHz Coupler (N-Type) 11 - 38 GHz Coupler
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-39
2.4.2 OMT (Ortho-Mode Transducer)
The OMT enables dual polarization feature to double the transmission
capacity for the PASOLINK system using the same frequency. The
following NEC OMT has ODU Direct Mount type for 11-38 GHz Bands,
which is suited for RFS Antenna and all NEC ODUs.
Fig. 2-9 OMT Transducer
Table 2-24 Characteristics
Frequency
Band
[GHz]
Frequency
Range
[GHz]
XPD Min.
[dB]
LOSS Max.
[dB]
P-P
ISOLATION
Min.[dB]
VSWR Max.
INTERFACE WG
INNER DIA. (mm)
(ANT Side)
INTERFACE (ODU
Side)
11 10.5 - 11.7 35 0.6 38 1.3 18.0
NEC original
13 12.75 - 13.25 35 0.6 38 1.3 15.0
15 14.5 - 15.35 35 0.6 38 1.3 13.5
18 17.7 - 19.7 35 0.6 38 1.3 10.5
23 21.2 - 23.6 35 0.6 38 1.3 9.0
26 24.5 - 26.5 35 0.8 38 1.3 8.0
32 31.8 - 33.4 35 1.0 38 1.3 6.5
38 37 - 39.5 35 1.0 38 1.3 5.5
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-40
2.5 RF Channel Plan
Radio frequencies in 6 to 52 GHz applicable to PASOLINK NEO are
shown in the following Table: For details of frequency range in each Sub
Band RF frequency band listed below, refer to the Appendix attached in
this Section 1.
Table 2-25 RF Frequencies
RF BAND [GHz] Tx-Rx Shift Frequency [MHz]
L6 GHz : 5.925 - 6.425 252.04/
266
U6 GHz : 6.43 - 7.11 340
7 GHz : 7.125 - 7.9 154/
161/
196/
245
8 GHz : 7.7 - 8.5 119/
126/
151.614/
154/
266/
294.44/
305.56/
310
311.32
10-11 GHz : 10.15 - 11.7 530
13 GHz : 12.75 - 13.25 266
15 GHz : 14.5 - 15.35 315/
420/
470/
490/
644/
728
18 GHz : 17.7 - 19.7 340/
750/
1008/
1010/
1092.5/
1120/
1250/
1560
23 GHz : 21.2 - 23.6 600/
1008/
1200/
1232
26 GHz : 24.5 - 26.5 855/
1008/
1123.5
28 GHz : 27.5 - 29.5 1008
32 GHz : 31.8 - 33.4 812
38 GHz : 37 - 39.5 700/
1000/
1260/
52 GHz : 51.4 - 52.6 616
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-41
2.6 Power Supply
The power supply systems are shown in Fig. 2-9 (1/3) to (3/3). The DC-
DC CONV module in the MODEM module produces regulated +3.6 V DC
from 48 V *1 DC input for the component modules on the IDU. Also,
this module supplies a 48 V DC to the ODU.
Caution: * 1 The 48 V power supply system for the PASOLINK
NEO must be separated from existing power supply
system. The PASOLINK, PASOLINK
+
, PASOLINK
Mx (excluding 52 GHz ODU for NEO), etc. That uses
43 V DC and floating polarities.
The DC V to the ODU is supplied through the coaxial cable which is also
used for the IF and other signals. The PS circuit on the ODU produces +7/
+8/+9/7/8/9 * and 15 V DC for the component modules from the 48
V DC supplied from the IDU.
Note: *: Necessary voltages in the ODU vary depending on the ODU
type.
Fig. 2-10 Power Supply System Block Diagram (1/3)
DC
INPUT
(1/3)
(2/4)
ODU (NEO)
PS SELV
48 V
TX IF
15 V
MODEM
DC-DC
IDU
48 V
SEP/
COMB
FIL
CTRL, STM-1 INTFC, 16E1 INTFC, 32E1INTFC,
48E1 INTFC, E3 INTFC, LAN/WS INTFC, GbE INTFC
CONV
ODU INTFC
G
48 V SEP/
COMB
FIL
RX IF
SV/CTRL
TX IF
RX IF
SV/CTRL
FUSE
PWR
7/8/9 V
+7/+8/+9 V
48 V
*
1
*
1
*
2
Notes: *1: The inner voltages vary depending on the ODU type.
*2: Optional
For 1+0 Configuration
For 1+0 Configuration
+3.6 V
48 V
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-42
Fig. 2-10 Power Supply System Block Diagram (2/3)
DC
INPUT
(1/3)
(2/4)
ODU (NEO)
SELV
48 V
TX IF
15 V
MODEM
DC-DC
IDU
48 V
SEP/
COMB
FIL
CTRL, STM-1 INTFC, 16E1 INTFC, 32E1 INTFC, 48E1
INTFC, E3 INTFC, LAN/WS INTFC, GbE INTFC
CONV
ODU INTFC
G
48 V SEP/
COMB
FIL
RX IF
SV/CTRL
TX IF
RX IF
SV/CTRL
FUSE
PWR
7/8/9 V
+7/+8/+9 V
48 V
*
1
*
1
DC
INPUT
(1/3)
(2/4)
ODU (NEO)
SELV
48 V
TX IF
15 V
MODEM
DC-DC
48 V
SEP/
COMB
FIL
CONV
ODU INTFC
G
48 V SEP/
COMB
FIL
RX IF
SV/CTRL
TX IF
RX IF
SV/CTRL
FUSE
PWR
7/8/9 V
+7/+8/+9 V
48 V
*
1
*
1
Notes: *1: The inner voltages vary depending on the ODU type.
*2: Optional
For 1+1 Configuration
*
2
PS
PS
+3.6 V
+3.6 V
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-43
Fig. 2-10 Power Supply System Block Diagram (3/3)
DC
INPUT
(1/3)
(2/4)
ODU (Excepting NEO)
PS SELV
()
TX IF
15 V
MODEM
DC-DC
IDU
43 V
SEP/
COMB
FIL
CTRL, STM-1 INTFC, 16E1 INTFC, 32E1 INTFC, 48E1
INTFC, E3 INTFC, LAN/WS INTFC, GbE INTFC
CONV
ODU INTFC
(+) 43 V SEP/
COMB
FIL
RX IF
SV/CTRL
TX IF
RX IF
SV/CTRL
FUSE
PWR
+3.6 V
7/8/9 V
+7/+8/+9 V
43 V
*
1
*
1
Notes: *1: The inner voltages vary depending on the ODU type.
*2: Optional
DC-DC
CONV
(1/3)
(2/4)
SELV
FUSE
PWR
FUSE
20 to 60 V/
+20 to +60 V
(1)
(2) 43 V
OUT
G
*
2
DC-DC CONV
*
2
For 1+0 Configuration
Connecting Other Type Pasolink ODU
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-44
44 pages
(This page is intentionally left blank.)