Artemis

Version 2.0
General Description, Specifications, and
Installation Manual

407506-2901-023-A00




Artemis Installation and Maintenance Manual
V2.0
Catalog No: X38833
June 2011
2 nd Edition






Copyright by ECI Telecom, 2010-2011. All rights reserved worldwide.
This is a legal agreement between you, the end user, and ECI Telecom Ltd. (ECI Telecom). BY OPENING THE
DOCUMENTATION AND/OR DISK PACKAGE, YOU ARE AGREEING TO BE BOUND BY THE TERMS OF THIS
AGREEMENT. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, PROMPTLY RETURN THE
UNOPENED DOCUMENTATION AND/OR DISK PACKAGE AND THE ACCOMPANYING ITEMS (INCLUDING
WRITTEN MATERIALS AND BINDERS OR OTHER CONTAINERS), TO THE PLACE FROM WHICH YOU
OBTAINED THEM.
The information contained in the documentation and/or disk is proprietary and is subject to all relevant copyright,
patent, and other laws protecting intellectual property, as well as any specific agreement protecting ECI Telecom's
rights in the aforesaid information. Neither this document nor the information contained in the documentation and/or
disk may be published, reproduced, or disclosed to third parties, in whole or in part, without the express prior
written permission of ECI Telecom. In addition, any use of this document, the documentation and/or the disk, or the
information contained therein for any purposes other than those for which it was disclosed, is strictly forbidden.
ECI Telecom reserves the right, without prior notice or liability, to make changes in equipment design or
specifications. Information supplied by ECI Telecom is believed to be accurate and reliable. However, no
responsibility whatsoever is assumed by ECI Telecom for the use thereof, nor for the rights of third parties, which
may be affected in any way by the use and/or dissemination thereof.
Any representation(s) in the documentation and/or disk concerning performance of ECI Telecom product(s) are for
informational purposes only and are not warranties of product performance or otherwise, either express or implied.
ECI Telecom's standard limited warranty, stated in its sales contract or order confirmation form, is the only warranty
offered by ECI Telecom.
The documentation and/or disk is provided AS IS and may contain flaws, omissions, or typesetting errors. No
warranty is granted nor liability assumed in relation thereto, unless specifically undertaken in ECI Telecom's sales
contract or order confirmation. Information contained in the documentation and in the disk is periodically updated,
and changes will be incorporated in subsequent editions. If you have encountered an error, please notify ECI
Telecom. All specifications are subject to change without prior notice.
The documentation and/or disk and all information contained therein is owned by ECI Telecom and is protected by
all relevant copyright, patent, and other applicable laws and international treaty provisions. Therefore, you must
treat the information contained in the documentation and disk as any other copyrighted material (for example, a
book or musical recording).
Other Restrictions. You may not rent, lease, sell, or otherwise dispose of the documentation and disk, as
applicable. YOU MAY NOT USE, COPY, MODIFY, OR TRANSFER THE DOCUMENTATION AND/OR DISK OR
ANY COPY IN WHOLE OR PART, EXCEPT AS EXPRESSLY PROVIDED IN THIS LICENSE. ALL RIGHTS NOT
EXPRESSLY GRANTED ARE RESERVED BY ECI Telecom.
All trademarks mentioned herein are the property of their respective holders.
ECI Telecom shall not be liable to you or to any other party for any loss or damage whatsoever or howsoever
caused, arising directly or indirectly in connection with this documentation and/or disk, the information contained
therein, its use, or otherwise. Notwithstanding the generality of the aforementioned, you expressly waive any claim
and/or demand regarding liability for indirect, special, incidental, or consequential loss or damage which may arise
in respect of the documentation and/or disk and/or the information contained therein, howsoever caused, even if
advised of the possibility of such damages.
The end user hereby undertakes and acknowledges that they read the "Before You Start/Safety Guidelines"
instructions and that such instructions were understood by them.
It is hereby clarified that ECI Telecom shall not be liable to you or to any other party for any loss or damage
whatsoever or howsoever caused, arising directly or indirectly in connection with you fulfilling and/or failed to fulfill
in whole or in part the "Before You Start/Safety Guidelines" instructions.


407506-2901-023-A00 ECI Telecom Ltd. Proprietary i

Contents
About This Manual .................................................................... ix
Overview ............................................................................................................. ix
Intended Audience .............................................................................................. ix
Document Organization ........................................................................................ x
Document Conventions ........................................................................................ x
Obtaining Technical Documentation ................................................................... xi
Technical Assistance .......................................................................................... xii
Introducing the Artemis .......................................................... 1-1
Overview .......................................................................................................... 1-1
Artemis Product Line ........................................................................................ 1-3
Features and Functions .................................................................................... 1-4
Shelf Layout ..................................................................................................... 1-5
Artemis Modules ...................................................................... 2-1
Overview .......................................................................................................... 2-1
Naming Convention .......................................................................................... 2-2
Passive OADM Modules .................................................................................. 2-3
Passive Mux/DeMux Modules ........................................................................ 2-13
Passive Optical Splitters/Couplers, Interleaver, and M-DCF Modules ........... 2-26
Accessories .................................................................................................... 2-35
Installing Artemis: Before You Start Safety Guidelines ....... 3-1
Overview .......................................................................................................... 3-1
General Safety Requirements .......................................................................... 3-1
Site Preparation and Rack Installation .................................. 4-1
Overview .......................................................................................................... 4-1
Unpacking and Performing Visual Inspection ................................................... 4-3
Rack Installation Options .................................................................................. 4-4
Preparing Cables and Fibers ............................................................................ 4-5
Equipment Installation ...................................................................................... 4-7
Rack Installation ............................................................................................... 4-8
Installing Ancillary Units in Racks ................................................................... 4-14
Installing Shelves and Modules ............................................. 5-1
Artemis Shelves Installation Options ................................................................ 5-1
Installing Modules in Artemis-1P and Artemis-2P ............................................ 5-8
Configuring the Artemis-2PE and Installing Modules ..................................... 5-15
Routing and Connecting Optical Fibers .......................................................... 5-25
Contents Artemis

ii ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Applications ............................................................................. 6-1
Overview .......................................................................................................... 6-1
Data Services Multiplexing ............................................................................... 6-2
Adding/Dropping Wavelengths ......................................................................... 6-3
Passive Optical Modules Complementary Solution for AccessWave ............... 6-4
Expanding CWDM Channels to DWDM ........................................................... 6-5
Single Fiber Application .................................................................................... 6-7
OADM Use as a Mux/DeMux ........................................................................... 6-9
Back-to-Back Connectivity ............................................................................. 6-11
Support for 32-Channel Multiplexing on Day One .......................................... 6-13
Artemis System Specifications ............................................. A-1
Overview .......................................................................................................... A-1
Physical Specifications ..................................................................................... A-6
Environmental Operation Conditions ................................................................ A-7
Standards and References ............................................................................... A-7


407506-2901-023-A00 ECI Telecom Ltd. Proprietary iii

List of Figures
Figure 1-1: Typical Artemis-1P shelf .............................................................................. 1-3
Figure 1-2: Typical Artemis-2P shelf .............................................................................. 1-3
Figure 1-3: Typical Artemis-2PE shelf ........................................................................... 1-3
Figure 1-4: Artemis-1P shelf general view ..................................................................... 1-5
Figure 1-5: Artemis-1P two single slot (default) configuration ....................................... 1-6
Figure 1-6: Artemis-1P four min-slot configuration ........................................................ 1-6
Figure 1-7: Artemis-1P double slot configuration ........................................................... 1-6
Figure 1-8: Artemis-2P shelf general view ..................................................................... 1-7
Figure 1-9: Artemis-2P four single slot (default) configuration ....................................... 1-7
Figure 1-10: Artemis-2P two single slot and four mini-slot configuration ....................... 1-8
Figure 1-11: Artemis-2PE shelf general view ................................................................. 1-8
Figure 1-12: Artemis-2PE eight mini-slot configuration ................................................. 1-9
Figure 1-13: Artemis-2PE two double slot configuration ................................................ 1-9
Figure 1-14: Artemis-2PE mixed slot configuration ....................................................... 1-9
Figure 1-15: Artemis-2PE quad slot (default) configuration ........................................... 1-9
Figure 2-1: Artemis OADM and Mux/DeMux naming .................................................... 2-2
Figure 2-2: C_OADM_S front panel ............................................................................... 2-4
Figure 2-3: 1-channel OADM functional block diagram ................................................. 2-4
Figure 2-4: C_OADM_D front panel ............................................................................... 2-5
Figure 2-5: 2-channel OADM functional block diagram ................................................. 2-6
Figure 2-6: C_OADM_Q front panel .............................................................................. 2-7
Figure 2-7: 4-channel OADM functional block diagram ................................................. 2-7
Figure 2-8: D_OADM_S front panel ............................................................................... 2-8
Figure 2-9: D_OADM_D front panel ............................................................................... 2-9
Figure 2-10: D_OADM_Q front panel .......................................................................... 2-10
Figure 2-11: Typical F_OADM850_xx front panel........................................................ 2-11
Figure 2-12: F_OADM850_xx functional block diagram .............................................. 2-12
Figure 2-13: CMD_O1 front panel ................................................................................ 2-14
Figure 2-14: C_MD_O1 functional block diagram ........................................................ 2-15
Figure 2-15: CMD_O2 front panel ................................................................................ 2-16
Figure 2-16: C_MD_O2 functional block diagram ........................................................ 2-17
Figure 2-17: DMD_H1 front panel ................................................................................ 2-18
Figure 2-18: 16-ch. Red band Mux/Demux block diagram .......................................... 2-19
Figure 2-19: D_MD_H2 front panel .............................................................................. 2-20
Figure 2-20: 16-ch. Red band Mux/Demux block diagram .......................................... 2-21
Figure 2-21: D_MD_40 front panel .............................................................................. 2-22
List of Figures Artemis

iv ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Figure 2-22: 40-channel C band Mux/Demux functional block diagram ...................... 2-23
Figure 2-23: D_MD_80 front panel .............................................................................. 2-24
Figure 2-24: 80-channel C band Mux/Demux functional block diagram ...................... 2-25
Figure 2-25: RB_FLTR front panel ............................................................................... 2-27
Figure 2-26: RB_FLTR functional block diagram ......................................................... 2-27
Figure 2-27: CT_FLTR 1310 nm front panel ................................................................ 2-28
Figure 2-28: CT_FLTR 1310 functional block diagram ................................................ 2-28
Figure 2-29: CT_FLTR 1510 nm front panel ................................................................ 2-29
Figure 2-30: CT_FLTR 1510 functional block diagram ................................................ 2-29
Figure 2-31: S/C-50_D front panel ............................................................................... 2-30
Figure 2-32: S/C-50_D functional block diagram ......................................................... 2-31
Figure 2-33: SPL-99_D front panel .............................................................................. 2-32
Figure 2-34: SPL-99_D functional block diagram ........................................................ 2-32
Figure 2-35: INTRLVR front panel ............................................................................... 2-33
Figure 2-36: INTRLVR functional block diagram ......................................................... 2-34
Figure 2-37: Example of an M-DCF_40 front panel ..................................................... 2-35
Figure 2-38: Spooler front view .................................................................................... 2-35
Figure 2-39: Spooler side view..................................................................................... 2-36
Figure 2-40: ETSI Fiber/Cable guide used below equipment ...................................... 2-37
Figure 2-41: ETSI Fiber/Cable guide used above equipment ...................................... 2-37
Figure 2-42: 19" Above/Below fiber guide ................................................................... 2-38
Figure 3-1: Laser warning label...................................................................................... 3-3
Figure 4-1: Mounting diagrams for ETSI racks ............................................................ 4-10
Figure 4-2: Mounting diagrams for 19" and 23" racks.................................................. 4-11
Figure 4-3: Rack mounting diagram for attachment to suspended overhead
tray (2200 mm rack) ..................................................................................................... 4-12
Figure 4-4: Example of an approved European 19" rack ............................................. 4-13
Figure 5-1: Artemis shelf with accessories installed in a rack ....................................... 5-2
Figure 5-2: Artemis-1P typical installation in a rack ....................................................... 5-3
Figure 5-3: Artemis-2P/E typical installation in a rack ................................................... 5-4
Figure 5-4: Attaching ETSI brackets to the Artemis-2P/E .............................................. 5-5
Figure 5-5: Attaching 23" ANSI brackets to the Artemis-2P/E ....................................... 5-6
Figure 5-6: Attaching ANSI 19" brackets to the Artemis-2P .......................................... 5-7
Figure 5-7: Installing a single slot module in an Artemis shelf ....................................... 5-9
Figure 5-8: Divider bracket identification ...................................................................... 5-10
Figure 5-9: Installing a divider bracket ......................................................................... 5-11
Figure 5-10: Installing a mini-slot module in an Artemis shelf ..................................... 5-12
Figure 5-11: Removing the divider bracket from the Artemis-1P ................................. 5-13
Figure 5-12: Installing a double slot module in the Artemis-1P shelf ........................... 5-14
Artemis List of Figures

407506-2901-023-A00 ECI Telecom Ltd. Proprietary v

Figure 5-13: Artemis-1P with a double slot module installed ....................................... 5-15
Figure 5-14: Installing a double slot module in the Artemis-2PE ................................. 5-16
Figure 5-15: Installing a quad slot module in the Artemis-2PE .................................... 5-17
Figure 5-16: Artemis-2PE default configuration ........................................................... 5-18
Figure 5-17: Lower and upper bracket general view ................................................... 5-19
Figure 5-18: Upper bracket identification ..................................................................... 5-20
Figure 5-19: Installing an upper bracket ...................................................................... 5-20
Figure 5-20: Lower bracket identification ..................................................................... 5-21
Figure 5-21: Removing a lower bracket cover ............................................................. 5-22
Figure 5-22: Installing a lower bracket ......................................................................... 5-22
Figure 5-23: Installing a single slot module in the Artemis-2PE .................................. 5-23
Figure 5-24: Installing a mini-slot module in the Artemis-2PE ..................................... 5-24
Figure 5-25: Fiber route for Artemis-1P installation ..................................................... 5-26
Figure 5-26: Fiber route for Artemis-2P installation ..................................................... 5-28
Figure 6-1: Data services multiplexing ........................................................................... 6-2
Figure 6-2: Wavelengths add/drop application .............................................................. 6-3
Figure 6-3: Passive optical cards complementary solution for AW ................................ 6-4
Figure 6-4: CWDM channels .......................................................................................... 6-5
Figure 6-5: Artemis CWDM to DWDM channel expansion ............................................ 6-6
Figure 6-6: Transmission system with a fiber pair ......................................................... 6-7
Figure 6-7: Transmission system with a single fiber ...................................................... 6-8
Figure 6-8: Artemis single fiber application .................................................................... 6-8
Figure 6-9: Artemis OADM use as a Mux/Demux ........................................................ 6-10
Figure 6-10: Artemis 8-channel multiplexing using two OADMs .................................. 6-11
Figure 6-11: Artemis back-to-back application ............................................................. 6-12
Figure 6-12: 32-channel multiplexing support .............................................................. 6-13
List of Figures Artemis

vi ECI Telecom Ltd. Proprietary 407506-2901-023-A00



407506-2901-023-A00 ECI Telecom Ltd. Proprietary vii

List of Tables
Table 2-1: Artemis OADM modules ........................................................................ 2-3
Table 2-2: F_OADM850_xx card types, add/drop, and blocked channels ........... 2-11
Table 2-3: Artemis Mux/Demux cards .................................................................. 2-14
Table 2-4: Artemis filter, splitter/coupler modules, and DCM card ....................... 2-26
Table 4-1: Main equipment dimensions .................................................................. 4-2
Table 4-2: Equipment rack data .............................................................................. 4-4
Table A-1: CWDM 1-, 2-, and 4-channel OADM specifications .............................. A-1
Table A-2: DWDM 1-, 2-, and 4-channel OADM specifications .............................. A-2
Table A-3: F_OADM850_xx card types, add/drop, and blocked channels ............. A-2
Table A-4: F_OADM850_xx specifications ............................................................. A-3
Table A-5: F_OADM850_xx environmental specifications ..................................... A-3
Table A-6: CWDM Mux/Demux 8-channel specifications ....................................... A-3
Table A-7: DWDM Mux/Demux FT 16-Ch. Red/Blue band and 40-Ch.
C band specifications ..................................................................................................... A-4
Table A-8: Coupler/Splitter 50%/50% SM specifications ........................................ A-4
Table A-9: Splitter 99%/1% SM specifications ........................................................ A-4
Table A-10: C/T Filter 1510 nm Mux/DeMux specifications ...................................... A-5
Table A-11: Red/Blue Filter specifications ................................................................ A-5
Table A-12: INTRLVR specifications ......................................................................... A-5
Table A-13: M-DCF_xx specifications ....................................................................... A-6
List of Tables Artemis

viii ECI Telecom Ltd. Proprietary 407506-2901-023-A00



407506-2901-023-A00 ECI Telecom Ltd. Proprietary ix

In this chapter:
Overview ........................................................................................................... ix
Intended Audience ............................................................................................. ix
Document Organization ...................................................................................... x
Document Conventions ...................................................................................... x
Obtaining Technical Documentation ................................................................. xi
Technical Assistance ........................................................................................ xii
Overview
The Artemis General Description and Installation describes the key
components of the Artemis, including, modules, accessories, and related
capabilities, and how to set up, configure, and install Artemis shelves and their
components.
The manual also provides task-oriented instructions for replacing hardware
components (modules, accessories).
Intended Audience
This manual is intended for optical network designers responsible for network
planning and for those responsible for installing the system and its accessories.
The instructions require you to understand and follow the safety practices
described here, as well as applicable national regulations and others enforced at
your site. They also require that you understand the physical, optical, and
electrical requirements of the installation site.
About This Manual
About This Manual Artemis

x ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Document Organization
This manual contains the following information:
Artemis shelves overview
Modules used in the Artemis shelves
Installation
Applications
System specifications
Document Conventions
When applicable, this manual uses the following conventions.
Convention Indicates Example
Bold Names of windows, dialog
boxes, menus, buttons, and
most other GUI elements
In the Alarms menu...
Menu > Option Selection from a menu, or
leading to another
command
Select Update > View
Objects
Italics New terms, emphasized
text, and names of manuals
and documents
Examples in text
Borders around text Notes, cautions, and
warnings
See examples below


NOTE: Text set off in this manner presents clarifying
information, specific instructions, commentary, sidelights, or
interesting points of information.


CAUTION: Text set off in this manner indicates that failure
to follow directions could result in damage to equipment or
loss of information.


WARNING: Text set off in this manner indicates that failure
to follow directions could result in bodily harm or loss of life.

Artemis About This Manual

407506-2901-023-A00 ECI Telecom Ltd. Proprietary xi


LASER WARNING: Text set off in this manner indicates
how to avoid personal injury. All personnel involved in
equipment installation, operation, and maintenance must be
aware that laser radiation is invisible. Therefore, although
protective devices generally prevent direct exposure to the
beam, personnel must strictly observe the applicable safety
precautions and, in particular, must avoid staring into optical
connectors, either directly or using optical instruments.


ESD: Text set off in this manner indicates information on
how to avoid discharge of static electricity and subsequent
damage to the unit.


TIP: Text set off in this manner includes helpful information
and handy hints that can make your task easier.


IMPORTANT: Text set off in this manner presents essential
information to which you must pay attention.
Obtaining Technical
Documentation
To obtain technical documentation related to ECI Telecom products, contact:
ECI Telecom Ltd.
Documentation Department
30 Hasivim St.
Petach Tikva 49130
Israel
Fax: +972-3-9268060
Email: techdoc.feedback@ecitele.com
About This Manual Artemis

xii ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Technical Assistance
The installation of the Artemis and its operation in a network are highly
specialized processes. Due to the different nature of each installation, some
planning aspects may not be covered in this manual.
If you have questions or concerns about your network design or if you require
installation personnel to perform the actual installation process, ECI Telecom
maintains a staff of design engineers and highly trained field service personnel.
The services of this group are available to customers at any time.
If you are interested in obtaining design assistance or a network installation
plan from ECI Telecom's Customer Support team, contact your ECI Telecom
sales representative. With any support related issues, technical or logistic,
contact the ECI Telecom Customer Support center at your location. If you are
not familiar with that location, contact our central customer support center
action line at:

Telephone +972-3-9266000

Telefax +972-3-9266370

Email on.support@ecitele.com


407506-2901-023-A00 ECI Telecom Ltd. Proprietary 1-1

In this chapter:
Overview ......................................................................................................... 1-1
Artemis Product Line....................................................................................... 1-3
Features and Functions .................................................................................... 1-4
Shelf Layout .................................................................................................... 1-5
Overview
ECI Telecom's Artemis is a family of platforms that accommodate a wide range
of optical passive components for CWDM and DWDM, including
Muxes/DeMuxes, OADMs, splitters/couplers, filters, and more.
The massive growth in data, video, and packet voice traffic creates significant
challenges for service providers. Expanding the transmission infrastructure to
accommodate more bandwidth requirements is essential. Wireline, wireless,
cable operators, and competitive carriers all face several problems, including:
Adding more bandwidth using the existing fiber plant
Investing in new telecom infrastructure that will be both cost-optimized and
future-proof
Reducing operating and maintenance costs
Responding quickly to new and unexpected traffic demands
Implementing new technologies without risking network reliability and
using the same infrastructure
1
Introducing the Artemis
Introducing the Artemis Artemis

1-2 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

To cope with these demands, service providers are looking for effective ways
to expand their network. They have significant fiber plant used to provide
customer services that are at exhaust or near-exhaust conditions. To reduce
capital expenditure (CAPEX) and operational expenditure (OPEX) and
increase profitability, service providers must offer both traditional and new
value-added services. CWDM and DWDM provide cost-effective and
easy-to-install and maintain bandwidth solutions that take full advantage of
existing fibers. Since fiber optic cabling is expensive to implement for each
individual service, a solution is to use WDM for expanding the capacity of the
fiber to carry multiple client interfaces. WDM is protocol transparent and
enables to carry different services, without interfering to each other, on the
same fiber.
ECI Telecom's Artemis shelves are fully passive optical platforms that
complement ECI Telecom's existing XDM, AccessWave, and CESR
families for optical passive components.
The Artemis is designed with the most advanced filtering technology, resulting
in lower attenuation, longer signal reach, and reduced total network cost. It
supports interworking with any product that complies with ITU-T G.694.2
(CWDM) and ITU-T G.694.1 (DWDM) standards, including all XDM
Mux/DeMux modules, AccessWave, and CESR platforms. The Artemis
platforms feature low cost, high modularity, small footprint, and very high
density.
Using the Artemis passive optical modules enables the customer to free slots in
existing platforms (like XDM, AccessWave, etc.) for more active modules
required to expand his network. This results in reduced total cost of ownership.
Artemis modules provide basic building blocks for the xWDM multiplexing
system. It can be used in most DWDM applications, such as triple play,
business connectivity, and more, mostly for access and metro networks.
Artemis Introducing the Artemis

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 1-3

Artemis Product Line
The Artemis product line includes fully passive optical platforms that address
all your passive optical component needs for all size ranges and configurations.
The Artemis-P product line is available in three shelf types:
Artemis-1P: compact 1U shelf with two single slots
Artemis-2P: compact 2U shelf with four single slots
Artemis-2PE: compact 2U shelf with enhanced slot configuration options
Each single slot in the Artemis-1P and in the upper section (only) in the
Artemis-2P can be divided into two mini-slots.
The Artemis-2PE comes in a basic configuration of a quad slot. The quad slot
can be configured as four single slots, or two double slots, or eight mini-slots.
The Artemis-2PE is designed with high flexibility, enabling to configure the
shelf with any mix of slot types according to the specific requirements.
The Artemis shelves can be installed in different rack types, including ETSI,
19", and 23". They are fully passive, don't require any power supply, and
feature an extended operating temperature range of -5 C to +60 C that makes
them ideal for deployment in street cabinets for outdoor applications.

Figure 1-1: Typical Artemis-1P shelf

Figure 1-2: Typical Artemis-2P shelf

Figure 1-3: Typical Artemis-2PE shelf
Introducing the Artemis Artemis

1-4 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

A wide range of CWDM and DWDM Mux/DeMux, OADMs,
splitters/couplers, M-DCFs, and filters are available for use with the Artemis
shelves. Most of them can be used in both shelves.
The passive optical components are available in four different module sizes:
Mini slot
Single slot
Double slot (only for Artemis-1P and Artemis-2PE)
Quad slot (only for the Artemis-2PE)
Features and Functions
Artemis shelves support a wide range of features and functionalities for
building an advanced cost-effective optical network, including:
Support of both CWDM and DWDM.
No need for power installation (fully passive elements).
Used with a range of optical modules, including:
CWDM and DWDM OADM filters (1, 2, 4 channels).
Fixed OADM modules.
CWDM and DWDM Mux/DeMux modules.
Splitters and couplers.
Interleaver module.
Micro Dispersion Compensation Fiber (M-DCF) for 5, 10, 20, 30, 40,
80, 100, and 120 km.
All filters (OADMs and Mux/DeMux), CWDM and DWDM, include two
monitoring points, which is extremely useful in the process of wavelength
equalization.
CWDM Mux/DeMux also has an internal 1310 nm OSC port.
Mux/DeMux modules are based on flat-top technology, especially designed
to support back-to-back connectivity, with minimal loss.
OADMs are based on East-West configuration, allowing network designers
and users to use them as small Mux/DeMux modules.
Although designed for high density, the Artemis uses LC connectors so that
adapters are not required.
Artemis meets the CE mark, a mandatory requirement in different parts of
the globe.
Artemis Introducing the Artemis

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 1-5

Shelf Layout
This section describes the layout of each shelf in the Artemis platforms.
Artemis shelves have been designed to facilitate simple installation and easy
maintenance. Live insertion of modules is allowed to support quick
maintenance and repair activities without affecting traffic. The cage design and
mechanical practice of all platforms conform to international mechanical
standards and specifications.
Artemis-1P Shelf
The Artemis-1P is a 1U shelf housed in a 239.5 mm (9.43 in.) deep, 443 mm
(17.4 in.) wide, and 43.4 mm (1.7 in.) high equipment cage. The Artemis-1P
features a highly flexible structure with a significantly small footprint. All
modules can be inserted even when the shelf delivers live traffic without
affecting it.

Figure 1-4: Artemis-1P shelf general view
The Artemis-1P shelf has a default configuration of two single slots. At the
customer site each single slot can be divided, into two mini-slots, by using a
divider bracket. The Artemis-1P can accommodate two single slot; or four
mini-slot modules or a combination, or one double slot module, by removing
the divider bracket between the single slots.
Introducing the Artemis Artemis

1-6 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

The following figures show these possible configurations. Combinations of
single slots and mini-slots in the same shelf are possible according to
requirements.


NOTE: Mix of single slot and two mini-slot modules is
possible, provided the mini-slot modules share the same
single slot space.


Figure 1-5: Artemis-1P two single slot (default) configuration

Figure 1-6: Artemis-1P four min-slot configuration

Figure 1-7: Artemis-1P double slot configuration
Artemis Introducing the Artemis

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 1-7

Artemis-2P Shelf
The Artemis-2P shelf is housed in a 239.5 mm (9.43 in.) deep, 443 mm (17.4
in.) wide, and 87.9 mm (3.46 in.) high equipment cage. The Artemis-2P
features a highly flexible structure with a significantly small footprint.

Figure 1-8: Artemis-2P shelf general view
The Artemis-2P shelf has a default configuration of four single slots. At the
customer site, each of the upper single slots can be divided into two mini-slots
by using a divider bracket. The lower slots cannot be modified to mini slots.
The Artemis-2P can accommodate four single slot, or two single slot and four
mini-slot modules, or a combination. The Artemis-2P doesn't support double
slot modules.
The following figures show these possible configurations. Combinations of
single slots and mini-slots in the same shelf are possible according to
requirements.


NOTE: Mix of single slot and two mini-slot modules in the
upper slots of the Artemis-2P is possible, provided the
mini-slot modules share the same single slot space.


Figure 1-9: Artemis-2P four single slot (default) configuration
Introducing the Artemis Artemis

1-8 ECI Telecom Ltd. Proprietary 407506-2901-023-A00


Figure 1-10: Artemis-2P two single slot and four mini-slot configuration
Artemis-2PE Shelf
The Artemis-2PE shelf is housed in a 239.5 mm (9.43 in.) deep, 443 mm (17.4
in.) wide, and 87.9 mm (3.46 in.) high equipment cage. The Artemis-2PE
features a highly flexible structure with a significantly small footprint.

Figure 1-11: Artemis-2PE shelf general view
The Artemis-2PE shelf has a default configuration of a quad slot. At the
customer site, the shelf can be configured into any configuration of required
slots, using appropriate divider brackets.
The Artemis-2PE was designed with very high flexibility options, which
enables each single slots to be configured as two mini-slots by using a divider
bracket. Each couple of horizontal adjacent single slots can be configured as a
double slot. The high flexibility of the Artemis-2PE means that any mix of
mini-slot, single slot and double slot modules is possible.
Artemis Introducing the Artemis

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 1-9

The following figures show just a few of the possible configurations in the
Artemis-2PE.

Figure 1-12: Artemis-2PE eight mini-slot configuration

Figure 1-13: Artemis-2PE two double slot configuration

Figure 1-14: Artemis-2PE mixed slot configuration

Figure 1-15: Artemis-2PE quad slot (default) configuration

Introducing the Artemis Artemis

1-10 ECI Telecom Ltd. Proprietary 407506-2901-023-A00



407506-2901-023-A00 ECI Telecom Ltd. Proprietary 2-1

In this chapter:
Overview ......................................................................................................... 2-1
Naming Convention ......................................................................................... 2-2
Passive OADM Modules ................................................................................. 2-3
Passive Mux/DeMux Modules ...................................................................... 2-13
Passive Optical Splitters/Couplers, Interleaver, and M-DCF Modules ......... 2-26
Accessories .................................................................................................... 2-35
Overview
This chapter provides a detailed description of the passive optical modules
available for the Artemis-1P and Artemis-2P shelves. Most of the modules can
be installed in either shelf.
2
Artemis Modules
Artemis Modules Artemis

2-2 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Naming Convention
The Artemis system uses a very simple method for naming filter modules
consisting of four strings. From its name, you can immediately identify the
module functions.

Figure 2-1: Artemis OADM and Mux/DeMux naming
The first letter represents the technology: D = DWDM, C = CWDM.
The second string represents the filter type: OADM or MD = Mux/DeMux.
The third letter indicates the port density in the module: S = Single, D =
Double, Q = Quad, O = Octet, H = Hex.
The last string consists two digits representing the first channel in the
ITU-T grid. For example, in a quad OADM designed for channels 21-24,
the last two digits are 21.
Only OADM modules use channel numbers. For Mux/DeMux naming
convection is H1 to represent the first section (channels 21 to 36) and H2 to
represent the second section (channels 45 to 60) of the DWDM ITU-T grid.
The following are examples of OADM and Mux/DeMux naming:
C_OADM_Q_55 - is a CWDM OADM module with four channels: 55, 57,
59, 61 (this is the ITU-T grid for CWDM).
D_MD_H2 - is a DWDM Mux/DeMux module with 16 channels in the
second section of the ITU-T grid (Ch. #45-60), Blue section.
D_MD_40 - is a double slot DWDM Mux/DeMux that supports a full
range of 40 channels.
Additional naming convections that apply to the Artemis shelves and other
modules (beside OADM or Mux/DeMux) are as follows:
Artemis-1P and Artemis-2P stand for passive chassis, 1U and 2U
respectively.
S/C-50 is a quad splitter/coupler module with 50% splitting ratio for Single
Mode fibers. It can be used as a splitter or a coupler.
D_SP-99/1 is a dual splitter module with 1% monitoring port for Single
Mode fibers.
Artemis Artemis Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 2-3

CT_FILTER_1310 is a single optical supervisory filter for 1310 nm.
CT_FILTER_1510 is a single optical supervisory filter for 1510 nm.
RB_FILTER are Red/Blue filters that enable expansion of D_MD_H1 (16
first section channels) with D_MD_H2 (16 second section channels) to
provide 32 channels.
M-DCF_xx is a Micro Dispersion Compensation Fiber. The last digits (xx)
designate the compensation distance in km.
Passive OADM Modules
The passive Optical ADM module (OADM) performs the channel add and drop
function. ECI Telecom offers a wide range of passive OADM modules for
Artemis platforms. Different OADM modules are available for CWDM and
DWDM. All OADM modules can be installed in any of the Artemis shelves.
As a standard, OADM modules for the Artemis are offered with different
numbers of channels:
1-channel
2-channel
4-channel
The following table lists the OADM modules available for the Artemis
platforms:
Table 2-1: Artemis OADM modules
Module Description Size (slots)
C_OADM_S CWDM OADM 1-channel, E/W, with 1%
monitoring point
Mini slot
C_OADM_D CWDM OADM 2-channel, E/W, with 1%
monitoring point
Mini slot
C_OADM_Q CWDM OADM 4-channel, E/W, with 1%
monitoring point
Mini slot
D_OADM_S DWDM OADM 1-channel, E/W, with 1%
monitoring point
Mini slot
D_OADM_D DWDM OADM 2-channel, E/W, with 1%
monitoring point
Mini slot
D_OADM_Q DWDM OADM 4-channel, E/W, with 2.5%
monitoring point
Mini slot
F_OADM850_xx DWDM OADM for fixed 7-channels, E/W , with
-20 dB (1 %) monitoring point
Single slot
Artemis Modules Artemis

2-4 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

C_OADM_S
The C_OADM_S is a CWDM OADM module with a single add/drop channel
for E/W configuration that occupies a mini slot in the Artemis shelf. All
connections to the module are made from the front panel and all connectors are
LC type.


NOTE: The C_OADM_S can be installed only in the upper
slots of the Artemis-2P shelf and in any slot of the
Artemis-1P.

The following figure shows the front panel of the C_OADM_S.

Figure 2-2: C_OADM_S front panel
Functional Block Diagram

Figure 2-3: 1-channel OADM functional block diagram
Artemis Artemis Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 2-5

The C_OADM_S module is designed to operate in an E/W configuration. The
module has two sections (drop and add), each with its own line input and line
output connectors.
The incoming line signal is applied to the LN IN connector of the drop
section. The drop section includes a DeMux that extracts the channel signal
from the LN IN signal.
The dropped channel signal appears at the CH Dxx connector (xx
designates the specific channel).
The output signal of the DeMux appears at the PT (Path-Through) OUT
connector of the drop section.
The add section includes a Mux which combines the channel add signal
applied to the CH Axx (xx designates the specific channel) connector with
the signal applied to the PT IN connector. The resulting signal appears at
the LN OUT connector.
In addition, 1%/99% splitters are installed at the drop line side and at the add
line side, enabling the monitoring of the OADM line input and output signals.
The drop line side monitoring signal appears at the MON LN 1% IN connector
and the add line side monitoring signal at the MON LN 1% OUT connector.
C_OADM_D
The C_OADM_D is a CWDM OADM module with two add/drop channels for
E/W configuration that occupies a mini slot in the Artemis shelf. All
connections to the module are made from the front panel and all connectors are
LC type.


NOTE: The C_OADM_D can be installed only in the upper
slots of the Artemis-2P 2U shelf and in any slot of the
Artemis-1P.

The following figure shows the front panel of the C_OADM_D.

Figure 2-4: C_OADM_D front panel
Artemis Modules Artemis

2-6 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Functional Block Diagram

Figure 2-5: 2-channel OADM functional block diagram
The C_OADM_D module is designed to operate in an E/W configuration. The
module has two sections (drop and add), each with its own line input and line
output connectors.
The incoming line signal is applied to the LN IN connector of the drop
section. The drop section includes a DeMux that extracts the channel
signals from the LN IN signal.
The dropped channel signals appear at the CH Dxx and CH Dyy connectors
(xx, yy designate the specific channels).
The output signal of the DeMux appears at the PT (Path-Through) OUT
connector of the drop section.
The add section includes a Mux which combines the channel add signals
applied to the CH Axx and CH Ayy (xx, yy designates the specific
channels) connectors with the signal applied to the PT IN connector. The
resulting signal appears at the LN OUT connector.
In addition, 1%/99% splitters are installed at the drop line side and at the add
line side, enabling the monitoring of the OADM line input and output signals.
The drop line side monitoring signal appears at the MON LN 1% IN connector
and the add line side monitoring signal at the MON LN 1% OUT connector.
Artemis Artemis Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 2-7

C_OADM_Q
The C_OADM_Q is a CWDM OADM module with four add/drop channels for
E/W configuration that occupies a mini slot in the Artemis shelf. All
connections to the module are made from the front panel and all connectors are
LC type.


NOTE: The C_OADM_Q can be installed only in the upper
slots of the Artemis-2P 2U shelf and in any slot of the
Artemis-1P.

The following figure shows the front panel of the C_OADM_Q.

Figure 2-6: C_OADM_Q front panel
Functional Block Diagram

Figure 2-7: 4-channel OADM functional block diagram
Artemis Modules Artemis

2-8 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

The C_OADM_Q module is designed to operate in an E/W configuration. The
module has two sections (drop and add), each with its own line input and line
output connectors.
The incoming line signal is applied to the LN IN connector of the drop
section. The drop section includes a DeMux that extracts the channel
signals from the LN IN signal.
The dropped channel signals appear at the CH Dxx to CH Dww connectors
(xx to ww designate the specific channels).
The output signal of the DeMux appears at the PT (Path-Through) OUT
connector of the drop section.
The add section includes a Mux which combines the channel add signals
applied to the CH Axx to CH Aww (xx to ww designate the specific
channels) connectors with the signal applied to the PT IN connector. The
resulting signal appears at the LN OUT connector.
In addition, 1%/99% splitters are installed at the drop line side and at the add
line side, enabling the monitoring of the OADM line input and output signals.
The drop line side monitoring signal appears at the MON LN 1% IN connector
and the add line side monitoring signal at the MON LN 1% OUT connector.
D_OADM_S
The D_OADM_S is a DWDM OADM module with a single add/drop channel
for E/W configuration that occupies a mini slot in the Artemis shelf. All
connections to the module are made from the front panel and all connectors are
LC type.


NOTE: The D_OADM_S can be installed only in the upper
slots of the Artemis-2P shelf and in any slot of the
Artemis-1P.

The following figure shows the front panel of the D_OADM_S.

Figure 2-8: D_OADM_S front panel
The D_OADM_S functional block diagram and functionality is identical to the
C_OADM_S (see Functional Block Diagram (page 2-4)).
Artemis Artemis Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 2-9

D_OADM_D
The D_OADM_D is a DWDM OADM module with dual add/drop channels
for E/W configuration that occupies a mini slot in the Artemis shelf. All
connections to the module are made from the front panel and all connectors are
LC type.


NOTE: The D_OADM_D can be installed only in the upper
slots of the Artemis-2P shelf and in any slot of the
Artemis-1P or Artemis-2PE.

The following figure shows the front panel of the D_OADM_D.

Figure 2-9: D_OADM_D front panel
The D_OADM_D functional block diagram and functionality is identical to the
C_OADM_D (see Functional Block Diagram (page 2-6)).
Artemis Modules Artemis

2-10 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

D_OADM_Q
The D_OADM_Q is a DWDM OADM module with four add/drop channels for
E/W configuration that occupies a mini slot in the Artemis shelf. All
connections to the module are made from the front panel and all connectors are
LC type.


NOTE: The D_OADM_Q can be installed only in the upper
slots of the Artemis-2P shelf and in any slot of the
Artemis-1P orArtemis-2PE shelves.

The following figure shows the front panel of the D_OADM_Q.

Figure 2-10: D_OADM_Q front panel
The D_OADM_Q functional block diagram and functionality is very similar to
the C_OADM_Q (see Functional Block Diagram (page 2-7)). The only
difference is that the monitoring points at the input and the output lines take a
sample of 2.5% of the input (or output) signals for monitoring purposes and not
1% as in the C_OADM_Q.
F_OADM850_xx
The F_OADM850_xx is a Fixed OADM module with seven add/drop channels
for E/W configuration that occupies one slot in the Artemis shelf. The module
adds/drops seven adjacent DWDM 50 GHz spaced channel; the eighth channel
is cut by the module's filter and can not be used. All connections to the module
are made from the front panel and all connectors are LC type.


NOTE: The F_OADM850_xx can be installed only in the
lower slots of the Artemis-2P shelf and in any slot of the
Artemis-2PE shelf.

Artemis Artemis Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 2-11

The F_OADM850_xx enables operators to add/drop of several of the
propagating channels, as a low-cost alternative to the more expensive ROADM
cards.


NOTE: The xx in the F_OADM850_xx designates the
number of the first add/drop channel in the ITU-T grid.

The F_OADM850_xx family includes 11 members corresponding to 11
combinations of eight adjacent channels. Note that in the F_OADM850_xx the
channels are spaced 50 GHz from each other (0.5 increments in the ITU-T
grid). Each card adds/drops seven channels. The closest channel to these seven
channels (at both ends) is blocked by the FOADM and does not come out on
any port.
The card types, add/drop, and blocked channels are listed in the following
table.
Table 2-2: F_OADM850_xx card types, add/drop, and blocked channels
Card type Add/Drop channels Blocked channels
F_OADM850_21 21, 21.5, 22, 22.5, 23, 23.5, 24 20.5, 24.5
F_OADM850_25 25, 25.5, 26, 26.5, 27, 27.5, 28 24.5, 28.5
F_OADM850_29 29, 29.5, 30, 30.5, 31, 31.5, 32 28.5, 32.5
F_OADM850_33 33, 33.5, 34, 34.5, 35, 35.5, 36 32.5, 36.5
F_OADM850_37 37, 37.5, 38, 38.5, 39, 39.5, 40 36.5, 40.5
F_OADM850_41 41, 41.5, 42, 42.5, 43, 43.5, 44 40.5, 44.5
F_OADM850_45 45, 45.5, 46, 46.5, 47, 47.5, 48 44.5, 48.5
F_OADM850_49 49, 49.5, 50, 50.5, 51, 51.5, 52 48.5, 52.5
F_OADM850_53 53, 53.5, 54, 54.5, 55, 55.5, 56 52.5, 56.5
F_OADM850_57 57, 57.5, 58, 58.5, 59, 59.5, 60 56.5, 60.5
The following figure shows a typical front panel of an F_OADM850_xx.

Figure 2-11: Typical F_OADM850_xx front panel
Artemis Modules Artemis

2-12 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Functional Block Diagram

Figure 2-12: F_OADM850_xx functional block diagram
The F_OADM850_xx module is designed to operate in an E/W configuration.
The module has two sections (drop and add), each with its own line input and
line output connectors.
The incoming line signal is applied to the LINE IN connector of the drop
section. The drop function is performed by a 7-skip-1 bandpass filter
followed by an 8 channel AWG filter that extract the channel signals from
the LINE IN signal.
The dropped channel signals appear at the CHxx, CHxx+0.5, CHxx+1,... to
CHxx+3 connectors (xx designate the first drop channel, the marking D
designates the drop channel output).
Artemis Artemis Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 2-13

The resulting signal after the channels drop appears at the EXP OUT
(Express output) connector of the drop section.
The input signal to the add section is applied to the EXP IN (Express input)
connector of the add section. The add function is performed by a 1 x 7
coupler followed by a 7-skip-1 bandpass filter.
The add signals are applied through the CHxx, CHxx+0.5, CHxx+1,... to
CHxx+3 connectors to the coupler (xx designate the first add channel, the
marking A designates the add channel input).
The resulting signal of the express input with the added channels appears at
the LINE OUT connector.
In addition, - 20 db/0 dB splitters are installed at the drop line side and at the
add line side, enabling the monitoring of the OADM line input and output
signals. The drop line side monitoring signal appears at the MON - 20 dB IN
connector and the add line side monitoring signal at the MON - 20 dB OUT
connector.
Passive Mux/DeMux Modules
ECI Telecom offers a wide range of passive Mux/DeMux modules for the
Artemis platforms. The DWDM Mux/DeMux modules are based on flat-top
technology, enabling back-to-back connectivity with lower attenuation
compared to other technologies. With this configuration, minimal (if any)
regeneration is required for the back-to-back Mux/DeMux connectivity.
Mux/DeMux modules are available for CWDM and DWDM with 8 (CWDM),
16 (DWDM), or 40 (DWDM) channels. The 8-channel and 16-channel
Mux/DeMux modules can be installed in any of the Artemis shelves, while the
40-channel Mux/DeMux can be installed in the Artemis-1P only.
Artemis Modules Artemis

2-14 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

The following table lists the Mux/DeMux modules available for the Artemis
platforms.
Table 2-3: Artemis Mux/Demux cards
Module Description Size (slots)
C_MD_O1 CWDM Mux/DeMux, 8 channels (47-61), with
OSC 1310 nm port and 1% monitoring point
Single slot
C_MD_O2 CWDM Mux/DeMux, 8 channels (27-45), with 1%
monitoring point
Single slot
D_MD_H1 DWDM Mux/DeMux, 16 channels (21-36) for the
Red band, with 1% monitoring point
Single slot
D_MD_H2 DWDM Mux/DeMux, 16 channels (45-60) for the
Blue band, with 1% monitoring point
Single slot
D_MD_40 DWDM Mux/DeMux, 40 channels (21-60) for the
full band, with 1% monitoring point
Double slot
D_MD_80 DWDM Mux/DeMux, 80 channels (20.5-60 with
50 GHz spacing) for the full band, with 1%
monitoring point
Quad slot
C_MD_O1
The C_MD_O1 is a CWDM Mux/DeMux module for eight channels with OSC
support. The module covers channels 47-61 of the CWDM ITU-T grid and can
be installed in any of the Artemis platforms. The C_MD_O1 occupies a single
slot in the Artemis shelf. All connections to the module are made from the front
panel and all connectors are LC type.
The following figure shows the front panel of the C_MD_O1.

Figure 2-13: CMD_O1 front panel
Artemis Artemis Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 2-15

The module has two sections:
Mux: Operates as an 8-channel CWDM multiplexer with an additional
OSC channel at 1310 nm. This section has a group of eight CH Mxx
connectors (xx designates the channel number), each marked with the
number of the channel in accordance with the ITU T Recommendation
G.694.2 grid. In addition, the Mux has a ninth input channel marked OSC
IN. The Mux output connector is identified as LN OUT. The LN OUT level
can be monitored at the MON 1% OUT connector.
DeMux: Operates as an 8-channel demultiplexer with an additional OSC
channel output at 1310 nm. This section has a group of eight CH Dxx
connectors (xx designates the channel number) also marked with the
G.694.2 channel number. The ninth connector is for the OSC channel
output and is marked OSC OUT. The DeMux input connector is identified
as LN IN. The LN IN level can be monitored at the MON 1% IN
connector.
Functional Block Diagram

Figure 2-14: C_MD_O1 functional block diagram
Artemis Modules Artemis

2-16 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

The C_MD_O1 module consists of a Mux section and a DeMux section with
an OSC capability:
The Mux section, whose functional block diagram is shown in part A of the
previous figure, combines the optical signals applied to the CH Mxx
connectors (xx designates the channel number) with the OSC signal (1310
nm) applied to the OSC IN connector, and provides the resulting signal at
the connector marked LN OUT.
The 1%/99% splitter connected in the line output path provides a 1%
sample of the optical output signal to the MON 1% OUT connector,
thereby enabling monitoring of the optical Mux output signal.
The DeMux section, whose functional block diagram is shown in part B of
the previous figure, separates the optical signals applied to the LN IN
connector in accordance with their wavelength and provides the resulting
signals at the CH Dxx connectors (xx designates the channel number). The
supervisory channel (OSC 1310 nm) output appears at the OSC OUT
connector.
The 1%/99% splitter connected in the line input path provides a 1% sample
of the optical input signal to the MON 1% IN connector, thereby enabling
monitoring of the optical DeMux input signal.
The module's OSC ports enable to manage the module from a remote
management station, without occupying any of the eight CWDM channels
used for data transmission.
C_MD_O2
The C_MD_O2 is a CWDM Mux/DeMux module for 8 channels. The module
covers channels 27-45 of the CWDM ITU-T grid and can be installed in any of
the Artemis platforms. The C_MD_O2 occupies one slot in the Artemis shelf.
All connections to the module are made from the front panel and all connectors
are LC type.
The following figure shows the front panel of the C_MD_O2.

Figure 2-15: CMD_O2 front panel
Artemis Artemis Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 2-17

The module has two sections:
Mux: Operates as an 8-channel CWDM multiplexer. This section has a
group of eight CH Mxx connectors (xx designates the channel number),
each marked with the number of the channel in accordance with the ITU T
Recommendation G.694.2 grid. The Mux output connector is identified as
LN OUT. The LN OUT level can be monitored at the MON 1% OUT
connector.
DeMux: Operates as an 8-channel demultiplexer. This section has a group
of eight CH Dxx connectors (xx designates the channel number) also
marked with the ITU-T G.694.2 channel number. The DeMux input
connector is identified as LN IN. The LN IN level can be monitored at the
MON 1% IN connector.
Functional Block Diagram

Figure 2-16: C_MD_O2 functional block diagram
Artemis Modules Artemis

2-18 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

The C_MD_O2 module consists of a Mux section and a DeMux section:
The Mux section, whose functional block diagram is shown in part A of the
previous figure, combines the optical signals applied to the CH Mxx
connectors (xx designates the channel number) and provides the resulting
signal at the connector marked LN OUT.
The 1%/99% splitter connected in the line output path provides a 1%
sample of the optical output signal to the MON 1% OUT connector,
thereby enabling monitoring of the optical Mux output signal.
The DeMux section, whose functional block diagram is shown in part B of
the previous figure, separates the optical signals applied to the LN IN
connector in accordance with their wavelength and provides the resulting
signals at the CH Dxx connectors (xx designates the channel number).
The 1%/99% splitter connected in the line input path provides a 1% sample
of the optical input signal to the MON 1% IN connector, thereby enabling
monitoring of the optical DeMux input signal.
D_MD_H1
The D_MD_H1 is a DWDM Mux/DeMux module for 16 channels in the Red
band (Ch. 21-Ch. 36). The module can be installed in any of the Artemis
platforms. The D_MD_H1 occupies one slot in the Artemis shelf. All
connections to the module are made from the front panel and all connectors are
LC type.
The following figure shows the front panel of the D_MD_H1.

Figure 2-17: DMD_H1 front panel
The module has two sections:
Mux: Operates as a 16-channel Red band multiplexer. This section has a
group of 16 CH Mxx connectors (xx designates the channel number), each
marked with the number of the channel in accordance with the ITU-T
Recommendation G.694.1 grid. The Mux output connector is identified as
LN OUT. The LN OUT level can be monitored at the MON 1% OUT
connector.
DeMux: Operates as a 16-channel Red band demultiplexer. This section has
a group of 16 CH Dxx connectors (xx designates the channel number) also
marked with the ITU-T G.694.1 channel number. The DeMux input
connector is identified as LN IN. The LN IN level can be monitored at the
MON 1% IN connector.
Artemis Artemis Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 2-19

The maximum number of channels in a system can be expanded from 16 to 32
during service by adding 16 channels in the Blue band to the 16 channels
available in the Red band. To support this application ECI Telecom offers
Mux/DeMux modules in the Blue band (D_MD_H2) and an RB Filter
(RB_FLTR) module. To avoid traffic affecting, while adding Blue band
channels it is essential to connect the RB_FLTR to the D_MD_H1 from day
one. For more details see Support for 32-Channel Multiplexing on Day One
(page 6-13).
Functional Block Diagram

Figure 2-18: 16-ch. Red band Mux/Demux block diagram
The D_MD_H1 module consists of a Mux section and a DeMux section:
The Mux section, whose functional block diagram is shown in part A of the
preceding figure, combines the optical signals applied to the CH Mxx
connectors (xx designates the channel number) and provides the resulting
signal at the connector marked LN OUT.
The 1%/99% splitter connected in the line output path provides a 1%
sample of the optical output signal to the MON 1% OUT connector,
thereby enabling monitoring of the optical Mux output signal.
Artemis Modules Artemis

2-20 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

The DeMux section, whose functional block diagram is shown in part B of
the previous figure, separates the optical signals applied to the LN IN
connector in accordance with their wavelength and provides the resulting
signals at the CH Dxx connectors (xx designates the channel number).
The 1%/99% splitter connected in the line input path provides a 1% sample
of the optical input signal to the MON 1% IN connector, thereby enabling
monitoring of the optical DeMux input signal.
D_MD_H2
The D_MD_H2 is a DWDM Mux/DeMux module for 16 channels in the Blue
band (Ch. 45-Ch. 60). The module can be installed in any of the Artemis
platforms. The D_MD_H2 occupies one slot in the Artemis shelf. All
connections to the module are made from the front panel and all connectors are
LC type.
The following figure shows the front panel of the D_MD_H2.


NOTE: The front panel of the D_MD_H2 is very similar to
the panel of the D_MD_H1; the only difference is the channel
numbering. For convenience the D_MD_H1 is also shown in
the following drawing.


Figure 2-19: D_MD_H2 front panel
The module has two sections:
Mux: Operates as a 16-channel Blue band multiplexer. This section has a
group of 16 CH Mxx connectors (xx designates the channel number), each
marked with the number of the channel in accordance with the ITU T
Recommendation G.694.1 grid. The Mux output connector is identified as
LN OUT. The LN OUT level can be monitored at the MON 1% OUT
connector.
DeMux: Operates as a 16-channel Blue band demultiplexer. This section
has a group of 16 CH Dxx connectors (xx designates the channel number)
also marked with the G.694.1 channel number. The DeMux input connector
is identified as LN IN. The LN IN level can be monitored at the MON 1%
IN connector.
Artemis Artemis Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 2-21

The maximum number of channels in a system can be expanded from 16 to 32
during service by adding 16 channels in the Blue band to the 16 channels
available in the Red band. To support this application ECI Telecom offers
Mux/DeMux modules in the Blue band and a RB Filter module. For more
information refer to D_MD_H1 (page 2-18) and RB_FLTR (page 2-27).


NOTE: The use of the D_MD_H1 and D_MD_H2
Mux/DeMux enables to support 32 channels in the ITU-T
G.649.1 grid, however the supported channels are not
continues as there is a gap of nine channels (channels 37 to
45) between the two sections. To avoid this gap it is
recommended to use the D_MD_40.
Functional Block Diagram
The D_MD_H2 functional block diagram is very similar to that of the
D_MD_H, which is shown in the following figure for convenience. The only
differences are the corresponding channel numbering.

Figure 2-20: 16-ch. Red band Mux/Demux block diagram
Artemis Modules Artemis

2-22 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

The D_MD_H2 module consists of a Mux section and a DeMux section:
The Mux section, whose functional block diagram is shown in part A of the
previous figure, combines the optical signals applied to the CH Mxx
connectors (xx designates the channel number) and provides the resulting
signal at the connector marked LN OUT.
The 1%/99% splitter connected in the line output path provides a 1%
sample of the optical output signal to the MON 1% OUT connector,
thereby enabling monitoring of the optical Mux output signal.
The DeMux section, whose functional block diagram is shown in part B of
the previous figure, separates the optical signals applied to the LN IN
connector in accordance with their wavelength and provides the resulting
signals at the CH Dxx connectors (xx designates the channel number).
The 1%/99% splitter connected in the line input path provides a 1% sample
of the optical input signal to the MON 1% IN connector, thereby enabling
monitoring of the optical DeMux input signal.
D_MD_40
The D_MD_40 is a DWDM Mux/DeMux module for 40 channels in the C
band (Ch. 21-Ch. 60). The module can be installed only in the Artemis-1P
shelf. The D_MD_40 occupies two slots in the Artemis-1P shelf. All
connections to the module are made from the front panel and all connectors are
LC type.


NOTE: The D_MD_40 can be installed only in the
Artemis-1P or Artemis-2PE shelves.

The following figure shows the front panel of the D_MD_40.

Figure 2-21: D_MD_40 front panel
Artemis Artemis Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 2-23

The module has two sections:
Mux: Operates as a 40-channel C band multiplexer. This section has a
group of 40 CH Mxx connectors (xx designates the channel number), each
marked with the number of the channel in accordance with the ITU T
Recommendation G.694.1 grid. The Mux output connector is identified as
LN OUT. The LN OUT level can be monitored at the MON 1% OUT
connector.
DeMux: Operates as a 40-channel C band demultiplexer. This section has a
group of 40 CH Dxx connectors (xx designates the channel number) also
marked with the G.694.1 channel number. The DeMux input connector is
identified as LN IN. The LN IN level can be monitored at the MON 1% IN
connector.
Functional Block Diagram

Figure 2-22: 40-channel C band Mux/Demux functional block diagram
The D_MD_40 module consists of a Mux section and a DeMux section:
The Mux section, whose functional block diagram is shown in part A of the
preceding figure, combines the optical signals applied to the CH Mxx
connectors (xx designates the channel number) and provides the resulting
signal at the connector marked LN OUT.
The 1%/99% splitter connected in the line output path provides a 1%
sample of the optical output signal to the MON 1% OUT connector,
thereby enabling monitoring of the optical Mux output signal.
Artemis Modules Artemis

2-24 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

The DeMux section, whose functional block diagram is shown in part B of
the previous figure, separates the optical signals applied to the LN IN
connector in accordance with their wavelength and provides the resulting
signals at the CH Dxx connectors (xx designates the channel number).
The 1%/99% splitter connected in the line input path provides a 1% sample
of the optical input signal to the MON 1% IN connector, thereby enabling
monitoring of the optical DeMux input signal.
D_MD_80
The D_MD_80 is a DWDM Mux/DeMux module for 80 channels in the C
band (includes Ch. 20.5 to Ch. 60 with 50 GHz spacing). The module can be
installed only in the Artemis-2PE shelf. The D_MD_80 occupies four (quad)
slots in the Artemis-2PE shelf. All connections to the module are made from
the front panel and all connectors are LC type.


NOTE: The D_MD_80 can be installed only in the
Artemis-2PE shelf.

The following figure shows the front panel of the D_MD_80.

Figure 2-23: D_MD_80 front panel
The module has two sections:
Mux: Operates as an 80-channel (50 GHz spacing) C band multiplexer.
This section has a group of 80 CH Mxx connectors (xx designates the
channel number), each marked with the number of the channel in
accordance with the ITU T Recommendation G.694.1 grid. The Mux
output connector is identified as LN OUT. The LN OUT level can be
monitored at the MON 1% OUT connector.
Artemis Artemis Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 2-25

DeMux: Operates as an 80-channel (50 GHz spacing) C band
demultiplexer. This section has a group of 80 CH Dxx connectors (xx
designates the channel number) also marked with the G.694.1 channel
number. The DeMux input connector is identified as LN IN. The LN IN
level can be monitored at the MON 1% IN connector.
Functional Block Diagram

Figure 2-24: 80-channel C band Mux/Demux functional block diagram
The D_MD_80 module consists of a Mux section and a DeMux section:
The Mux section, whose functional block diagram is shown in part A of the
preceding figure, combines the optical signals applied to the CH Mxx
connectors (xx designates the channel number) and provides the resulting
signal at the connector marked LN OUT.
The 1%/99% splitter connected in the line output path provides a 1%
sample of the optical output signal to the MON 1% OUT connector,
thereby enabling monitoring of the optical Mux output signal.
The DeMux section, whose functional block diagram is shown in part B of
the previous figure, separates the optical signals applied to the LN IN
connector in accordance with their wavelength and provides the resulting
signals at the CH Dxx connectors (xx designates the channel number).
The 1%/99% splitter connected in the line input path provides a 1% sample
of the optical input signal to the MON 1% IN connector, thereby enabling
monitoring of the optical DeMux input signal.
Artemis Modules Artemis

2-26 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Passive Optical
Splitters/Couplers, Interleaver,
and M-DCF Modules
Optical filters are used to separate or combine Red and Blue signals in the C
band. Splitters are used to divide an input signal into two equal signals and
couplers are used to combine two input signals. The Interleaver is used to
combine two streams of 40 channel signals, each with a 100 GHz spacing, into
one stream of 80 channels with 50 GHz spacing. M-DCF modules are required
to correct excessive dispersion on long fibers. All these module and module
types are required for various applications in optical networks.
ECI Telecom offers a wide range of these modules and modules for the
Artemis shelves. All modules can be installed in any Artemis shelf.
The following table lists the optical filters, splitter/coupler modules and
M-DCF modules available for the Artemis platforms.
Table 2-4: Artemis filter, splitter/coupler modules, and DCM card
Module Description Size (slots)
RB_Filter Red/Blue filter for expanding D_MD_H1 with
D_MD_H2 to 32 channels
Mini slot
CT_FLTR 1310 Single optical filter with an 1310 nm OSC port Mini slot
CT_FLTR 1510 Single optical filter with an 1510 nm OSC port Mini slot
S/C-50_D Dual splitter/coupler modules (2+2) with 50%
splitting ratio
Mini slot
SPL-99_D Dual splitter modules with 99%/1% ratio for
monitoring
Mini slot
INTRLVR Interleaver module for 40 Odd (100 GHz spacing)
and 40 Even (100 GHz spacing) channels
Single slot
M-DCF_xx
1
Dispersion compensation module for 5, 10, 20, 30,
40, 60, 80, 100, and 120 km
Single slot

1
xx designates the distance in Km.
Artemis Artemis Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 2-27

RB_FLTR
The RB_FLTR is a passive optical filter used to separate or combine a C band
input signal into Red and Blue signals. The module can be installed in any of
the Artemis platforms and occupies a mini slot. All connections to the module
are made from the front panel and all connectors are LC type.
The following figure shows the front panel of the RB_FLTR.

Figure 2-25: RB_FLTR front panel
The RB_FLTR incorporates a pair of Mux and DeMux:
The DeMux is used to separate a C band signal into a Red band signal and
a Blue band signal. The DeMux has one input (LN IN) and two output
connectors, R OUT (Red band) and B OUT (Blue band).
The Mux is used to combine the Red and Blue signals before they are sent
to the line. The Mux has two input (R IN and B IN), and one output
connector (LN OUT).
The following figure shows a functional block diagram of the RB_FLTR.

Figure 2-26: RB_FLTR functional block diagram
Artemis Modules Artemis

2-28 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

CT_FLTR 1310
The CT_FLTR 1310 is a single optical filter with an 1310 nm OSC port that
can be installed in any of the Artemis platforms and occupies a mini slot. All
connections to the module are made from the front panel and all connectors are
LC type.
The following figure shows the front panel of the CT_FLTR 1310.

Figure 2-27: CT_FLTR 1310 nm front panel
The module works with an OSC Mux/DeMux pair:
The OSC DeMux is used to separate the 1310 nm optical OSC from the C
band payload signal (in the 1550 nm range). The DeMux has one input
connector (LN IN) and two output connectors, C OUT (C band) and OSC
(1310 nm) OUT (OSC signal).
The OSC Mux is used to combine the two signals before they are sent to
the line. The Mux has two input connectors, C IN (C band) and OSC (1310
nm) IN (OSC signal), and one output connector, LN OUT.
The following figure shows the functional block diagram of the CT_FLTR
1310.

Figure 2-28: CT_FLTR 1310 functional block diagram
Artemis Artemis Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 2-29

CT_FLTR 1510
The CT_FLTR 1510 is a single optical filter with an 1510 nm OSC port that
can be installed in any of the Artemis platforms and occupies a mini slot. All
connections to the module are made from the front panel and all connectors are
LC type.
The following figure shows the front panel of the CT_FLTR 1510.

Figure 2-29: CT_FLTR 1510 nm front panel
The module works with an OSC Mux/DeMux pair:
The OSC DeMux is used to separate the 1510 nm optical OSC from the C
band payload signal (in the 1550 nm range). The DeMux has one input
connector (LN IN) and two output connectors, C OUT (C band) and OSC
(1510 nm) OUT (OSC signal).
The OSC Mux is used to combine the two signals before they are sent to
the line. The Mux has two input connectors, C IN (C band) and OSC (1510
nm) IN (OSC signal), and one output connector, LN OUT.
The following figure shows the functional block diagram of the CT_FLTR
1510.

Figure 2-30: CT_FLTR 1510 functional block diagram
Artemis Modules Artemis

2-30 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

S/C-50_D
The S/C-50_D is a dual splitter/coupler with 50% ratio module that includes
four identical splitter/coupler units. The module can be installed in any of the
Artemis platforms and occupies a mini slot. All connections to the module are
made from the front panel and all connectors are LC type.
The splitters divide an input signal into two equal signals. The couplers
combine two input signals. The S/C-50_D provides dual splitter/coupler units,
supporting up to two fixed protected services simultaneously.


NOTE: The S/C-50_D can also be used as a quad splitter or
quad coupler.

The following figure shows the front panel of the S/C-50_D.

Figure 2-31: S/C-50_D front panel
The front panel markings do not refer to splitter or coupler but rather to Units,
because each splitter can function as a coupler, depending on the direction of
the signals provided by the user.
Artemis Artemis Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 2-31

The following figure shows the functional block diagram of the S/C-50_D.

Figure 2-32: S/C-50_D functional block diagram
The module has four splitters/couplers, each marked Unit_A, Unit_B, Unit_C,
and Unit_D. Each unit has three connectors, marked P1, P2, and Agg. When
Unit_A is used as a splitter, the input signal is connected to its Agg. connector
and two equal output signals are received at connectors P1 and P2. When
Unit_A is used as a coupler, two signals are connected to connectors P1 and P2
and the resulting combined signal is provided at connector Agg.
Artemis Modules Artemis

2-32 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

SPL-99_D
The SPL-99_D is dual 99%/1% splitters for signal monitoring. The module can
be installed in any of the Artemis platforms and occupies a mini slot. All
connections to the module are made from the front panel and all connectors are
LC type.
The following figure shows the front panel of the SPL-99_D.

Figure 2-33: SPL-99_D front panel
The following figure shows the functional block diagram of the SPL-99_D.

Figure 2-34: SPL-99_D functional block diagram
The SPL-99_D can be installed in series with an optical line output or input in
order to monitor the optical signal level. The line signal is connected to the
SPA IN or SPB IN connectors. The continuing line is connected to the SPA
OUT 99% or SPB OUT 99% connectors, which provide 99% of the original
line power. An optical measurement device can be connected for monitoring to
the output connectors Mon A 1% or Mon B 1%, which provide 1% sample of
the input power signal.
Artemis Artemis Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 2-33

INTRLVR
The INTRLVR is an interleaver module that enables customers that have 40
channels to expand their system to 80 channels, with non-traffic affecting
scalability. The module can be installed in any of the Artemis platforms and
occupies a single slot. All connections to the module are from the front panel
and all connectors are LC type.
Basically, the C band is split into two groups of 40 ITU-T channels, both
spaced 100 GHz apart. Each group is offset by 50 GHz from the other. The first
group has channel numbers from 21, 22, 23, etc., through 60, with channel 21
signifying 192.1 THz. These are also designated Even channels. The second
group has channel numbers from 20.5, 21.5, 22.5, etc., through 59.5, with
channel 20.5 signifying 192.05 THz. These channels are also designated Odd
channels.
The two groups of 40 channels can be combined into an 80 channel system
using the INTRLVR module. The following figure shows the front panel of the
INTRLVR.

Figure 2-35: INTRLVR front panel
The module has two sections:
Interleaver: Operates as a 2 input multiplexer. This section has two input
connectors, marked ODD IN and EVEN IN, which connect to the
corresponding Odd channels signal (channel 20.5 to 59.5 in ITU-T G.694.1
grid), and Even channels signal (channel 21 to 60 in ITU-T G.694.1 grid).
The resulting interleaved 80 channels signal is provided through the LN
OUT connector.
DeInterleaver: Operates as a 2 output demultiplexer. This section has two
output connectors marked ODD OUT and EVEN OUT, which provides to
the corresponding Odd channels signal (channel 20.5 to 59.5 in ITU-T
G.694.1 grid), and Even channels signal (channel 21 to 60 in ITU-T
G.694.1 grid). The deinterleaver input connector is identified as LN IN.
Artemis Modules Artemis

2-34 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Functional Block Diagram

Figure 2-36: INTRLVR functional block diagram
The INTRLVR module consists of an Interleaver section and a DeInterleaver
section:
The Interleaver section, whose functional block diagram is shown in part A
of the preceding figure, takes the two multiplexed signals with 100-GHz
spacing connected to the corresponding ODD IN and EVEN IN connectors
and interleaves them. The resulting DWDM signal with channels spaced 50
GHz apart is provided through the connector marked LN OUT.
The DeInterleaver section, whose functional block diagram is shown in part
B of the previous figure, separates the optical signal applied to the LN IN
connector in accordance with their wavelength and provides the resulting
signals at the ODD OUT and EVEN OUT connectors.
Artemis Artemis Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 2-35

M-DCF_xx
The M-DCF_xx is a Micro Dispersion Compensation Fiber used to correct
excessive dispersion (for compensation values, refer to M-DCF_xx
specifications) on long fibers. The M-DCF_xx is available for several distance
ranges: 5, 10, 20, 30, 40, 60, 80, 100, and 120 km (xx in the module name
designates the distance in km). The module can be installed in any of the
Artemis platforms and occupies a single slot. All connections to the module are
made from the front panel and all connectors are LC type.
The following figure shows an example of the front panel of the M-DCF_xx
module.

Figure 2-37: Example of an M-DCF_40 front panel
Accessories
ECI Telecom offers several accessories, described in this section, to help you
carry out an efficient and optimal installation of the Artemis-P equipment in
racks. If you need custom modification to standard items, contact ECI
Telecom's support team or your ECI Telecom sales representative.
Fiber Spooler
The fiber spooler is used to roll and store excess optical fibers. Depending on
the spooler configuration, several hundreds of optical fibers can be stored (each
stored fiber can be max. 2.5 meters (8.1 feet) long). The following figure shows
a front view of the spooler.

Figure 2-38: Spooler front view
Artemis Modules Artemis

2-36 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

The spooler units are attached to the rack frame using the two anchoring panels
on the two sides. Fiber cables are wrapped in a figure-eight pattern around the
four storage posts in the spooler. These posts are large enough to accommodate
a large number of fibers that can be part of a typical installation. The following
figure illustrates the depth of the fiber storage area available within the spooler.

Figure 2-39: Spooler side view
Fiber/Cable Guide
The Fiber/Cable guide is a dual-purpose unit that can be used for both fiber and
cable routing. The Fiber/Cable guide helps to neatly route fibers connected
between front panels of modules installed in racks into ducts installed on the
sides of the rack. The guide also helps keep the recommended bending radius
of the routed fibers to prevent fiber break or signal degradation within the fiber.
Routing the fibers through fiber guides cancels the load resulting from the
fibers self-weight on the optical connectors. It also enables optimal
distribution of fiber bundles in accordance with the location of the modules
they serve, and comfortable module removal for maintenance or repair
purposes. This fiber guide has a significant advantage as it features arched
radius-keeping movable elements through which the fibers pass. If a module
needs to be extracted for maintenance or repair, access is easy by releasing
these elements and moving the fibers aside. After the activity, the fibers are
returned to the radius-keeping elements. The use of Fiber/Cable guides gives an
organize look-and-feel of the system, especially in installations with multiple
fibers/cables.
ECI Telecom Fiber/Cable guides are available in four versions according to
rack type and location relative to the equipment:
For ETSI racks above the equipment shelf
For ETSI racks below the equipment shelf
For 19" racks above the equipment shelf
For 19" racks below the equipment shelf
Artemis Artemis Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 2-37

The following figures show the ETSI Fiber/Cable guide. The 19" Fiber/Cable
guide is very similar.

Figure 2-40: ETSI Fiber/Cable guide used below equipment

Figure 2-41: ETSI Fiber/Cable guide used above equipment
These Fiber/Cable guides can also be adapted for use in other racks. The 19"
guides can be installed in ANSI 19" racks using a spacer adapter kit. The ETSI
guides can be installed in ANSI 23" racks using a bracket kit.
Above/Below Fiber Guide
The Above/Below fiber guide can be installed directly above or below the
equipment it serves. The same unit used for installation above the equipment
can be used under the equipment simply by reversing its position.
The above/below fiber guide can be used to route fibers up or down the shelf.
In applications in which it is installed below the equipment, fibers connected to
the modules are routed downwards to the fiber guide, directed to the ducts on
both sides of the rack, and upwards. The lower part of the fiber guide serves as
a tray and prevents the fibers from falling down. When required to route fibers
upwards, the fiber guide is installed above the equipment. In this case fibers are
routed from the equipment upwards to the fiber guide and directed left or right,
as required.
Artemis Modules Artemis

2-38 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

ECI Telecom offers the Above/Below fiber guide in two versions according to
rack type:
For ETSI racks
For 19" racks
The fiber guides are very similar.

Figure 2-42: 19" Above/Below fiber guide
These fiber guides can be adapted for use in other racks. The 19" fiber guide
can be installed in ANSI 19" racks using a spacer adapter kit. The ETSI fiber
guide can be installed in ANSI 23" racks using a bracket kit.


407506-2901-023-A00 ECI Telecom Ltd. Proprietary 3-1

In this chapter:
Overview ......................................................................................................... 3-1
General Safety Requirements .......................................................................... 3-1
Overview
This chapter describes the Artemis safety guidelines. Read the safety rules and
warnings carefully before beginning any platform installation or maintenance
work. These safety guidelines must be adhered.
General Safety Requirements


NOTE: Though the Artemis shelves are fully passive, you
must be familiar with the safety requirements because
equipment connected to power sources, like test equipment,
may operate near the Artemis shelves.

Make sure to install the platform in compliance with the following guidelines:
Be sure to use the equipment in restricted-access locations only.
Note that the equipment racks and Artemis platforms are suitable for
mounting on concrete or other noncombustible surfaces only.
Ensure the integrity of the grounding connections.
Artemis platforms must be installed in accordance with the National
Electrical Code.
3
Installing Artemis: Before
You Start Safety Guidelines
Installing Artemis: Before You Start
Safety Guidelines
Artemis

3-2 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Make sure that sufficient lighting is available while working on the
equipment.
Do not work on any equipment when it is connected to a voltage source
(DC or AC), except for inserting/removing modules; these activities can be
performed on operating equipment.
Ensure that the maximum working temperature does not exceed 50C.
Use only insulated tools during installation.
Wear protective clothing as required by the requisite safety regulations.
Do not install or maintain equipment connected to external lines (for
example, electrical tributaries) during thunderstorms.
Avoid contact with high voltage sources when installing platform and
modules.
Make sure you are familiar with the warning signals and labels affixed to
the equipment and observe the procedures strictly.
Grounding Requirements
Rack Grounding Requirements
Connect the rack to the site grounding bar with a ground cable according to
ETSI recommendations (top/bottom connection).
The rack is supplied with a main copper or brass grounding bolt welded to the
rack frame. The grounding stud is identified on the rack by the ground symbol
label.
The rack grounding bolt must be connected to the site grounding bar by a 35
mm
2
(2 AWG) grounding cable or thicker, as short as possible, complying with
UL/ETSI recommendations. The bolt must be free of paint. The cable must be
made of copper strands and terminated on both sides with bolt terminals.
The rack mounting rails must be free of paint and provide electrical continuity
to the main grounding bolt. The resistance between any rail and the rack main
grounding bolt must be less than 0.1 .
Artemis Installing Artemis: Before You Start
Safety Guidelines

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 3-3

Laser Safety Requirements
Laser Classification
The equipment and components with laser devices described in this manual
comply with the International Electrotechnical Commission (IEC) safety
standards, including IEC-60825-1 - Safety of Laser Products (AS/NZS 2211.2)
and IEC-825 Safety of Optical Fiber Communication Systems.
With specific regard to the laser, Artemis equipment complies with laser
product performance standards set by government agencies for Class 1 laser
products. The product and its accessories do not emit hazardous light, and the
beam is totally enclosed during all operating modes and maintenance.
Warning Labels for Laser Products
The following labels are affixed to the shelf front panel. The labels indicate that
the product is classified as a Class 1 Laser Product, Hazard Class 1M.

Figure 3-1: Laser warning label
Laser Safety Statutory Warning
All personnel involved in equipment installation and maintenance must be
aware that laser radiation is invisible. Therefore, although protective devices
generally prevent direct exposure to the beam, personnel must strictly observe
the applicable safety precautions and in particular must avoid staring into
optical connectors, either directly or through optical instruments.
Installing Artemis: Before You Start
Safety Guidelines
Artemis

3-4 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Laser Device Operating Precautions
In addition to the general precautions described in this section, be sure to
observe the following warnings when operating a product equipped with a laser
device. Failure to observe these warnings could result in fire, bodily injury, and
damage to the equipment.


WARNING: To reduce the risk of exposure to hazardous
radiation, note the following:
When performing maintenance and other activities on
equipment using lasers, it is recommended that you use
protection goggles for the wavelength range of 1300 nm to
1600 nm.
Only authorized personnel must carry out hot insertion or
swapping of an optical module or optical interface
module.
To prevent irremediable damage to your eyes, avoid
looking into the fiber when hot-removing and/or inserting
a fiber termination.
Place plastic covers on module fiber ports and fiber
terminations that are not currently in use.
Do not operate controls, make adjustments, or perform
procedures associated with the laser device other than
those specified herein.
It is strictly forbidden to interfere with any protective devices
and interlocks that are used to prevent direct exposure to the
laser beam.


407506-2901-023-A00 ECI Telecom Ltd. Proprietary 4-1

In this chapter:
Overview ......................................................................................................... 4-1
Unpacking and Performing Visual Inspection ................................................. 4-3
Rack Installation Options ................................................................................ 4-4
Preparing Cables and Fibers ............................................................................ 4-5
Equipment Installation ..................................................................................... 4-7
Rack Installation .............................................................................................. 4-8
Installing Ancillary Units in Racks ............................................................... 4-14
Overview
The following sections describe the conditions required for installing the
equipment at the site, including site preparation, power sources, rack
installation, preparing cables and fibers, installing ancillary units and more.
Site Preparation
Perform a preliminary survey of the installation site, taking into consideration
the following issues:
System environmental requirements
Physical location of the Artemis shelves
Location of power sources
Types of interfaces used at the site (optical, management, and so on)
Work and equipment safety requirements
4
Site Preparation and Rack
Installation
Site Preparation and Rack
Installation
Artemis

4-2 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Site Environmental Requirements
The following environmental conditions must be provided at the installation
site.
Parameter Compliance requirements
Electromagnetic interference FTZ 1TR9, EN 55022-2/2003, EN 50082-1/97
Temperature ETSI ETS 300-19-2-3 Test Spec. T3.1
Main Equipment Dimensions
Table 4-1: Main equipment dimensions
Equipment type Height
(mm)
Width
(mm)
Depth
(mm)
Max. weight (kg)
Artemis-1P 43.4 443 239.5 6.2
Artemis-2P 87.9 443 239.5 10.4
Artemis-2PE 88 443 239.5 8.5
Physical Location


WARNING: Artemis shelves are intended for installation in
restricted-access areas only.

Choose the physical location of the Artemis shelves, taking the following
aspects into consideration:
1. Equipment dimensions, as specified in Main Equipment Dimensions (page
4-2).
2. Routing requirements for power and management cables and optical fibers.
To ensure convenient access to cables and fibers, it is recommended to use
overhead cable ladders when ever possible to bring the cables/fibers to the
top of each rack.
Artemis Site Preparation and Rack
Installation

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 4-3

Unpacking and Performing
Visual Inspection
Before you start:
Before unpacking, make a preliminary inspection of the shipping boxes.
Immediately report evidence of damage to the carrier, the project manager, and
your local ECI Telecom representative.
You must unpack the equipment on a clean flat surface.
To unpack the equipment:
1. Place the shipping boxes with the top upwards, cut the sealing tape using a
short knife so as not to damage the internal items, and open the top flaps.
2. Remove the items contained in the box and inspect each item for damage.
Check for loose parts or any visual damage to the rack, shelf, and auxiliary
equipment. Also check the integrity of all the connectors, leads, and cables.


NOTE: Do not remove plastic covers from optical connectors
until optical cables are connected to them.

3. Search the shipping boxes for any additional small items that may be
present.
4. Open each of the module packages for inspection but do not remove the
modules from their individual protective packages until they can be
inserted in the shelf.
5. Check the contents of the shipping boxes against the packing list attached
to each box. If damaged parts are detected or if any parts are missing,
notify the project manager and your local ECI Telecom representative.
Site Preparation and Rack
Installation
Artemis

4-4 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Rack Installation Options
Artemis platforms can be installed in the following rack types:
ECI Telecom's recommended enhanced ETSI optical rack (hereafter
referred to as the optical rack) or the improved ETSI rack (hereafter
referred to as ETSI A). These racks have been specially adapted by ECI
Telecom and are tailored to meet platform requirements and simplify
platform installation and maintenance, including the following benefits:
Removable rear and side panels for tidy routing and efficient
maintenance of all rack cables, including:
Control cables
Power cables
Data cables (where relevant)
Two channels on the racks front rails for routing up to 400 (ETSI A) or
800 (optical rack) optical fibers.
Open frame top and bottom for easy routing of cables from suspension
floors and/or ceiling ladders.
Perforated door for free air flow to the installed equipment (see
Environmental Requirements).
Front door for left or right opening mounting.
Standard ETSI rack (hereafter referred to as ETSI B).
ISO 19 rack and standard US rack. These racks should be used only in
consultation with and when approved by ECI Telecom's Mechanical
Department.
Artemis rack options are summarized in the following table.
Table 4-2: Equipment rack data
Type Height Width Depth Available space
Optical
Rack
2200 mm 600 mm 300 mm 47U (2100 mm)
ETSI A 2200 mm 600 mm 300 mm 46U (2050 mm)
ETSI A 2600 mm 600 mm 300 mm 55U (2450 mm)
ETSI B 2200 mm 600 mm 300 mm 46U (2050 mm)
ETSI B 2600 mm 600 mm 300 mm 55U (2450 mm)
US 7 ft.
(2134 mm)
23 in.
(585 mm)
12 in.
(305 mm)
44U
(6.5 ft./1960 mm)
US 7 ft.
(2134 mm)
19 in.
(483 mm)
12 in.
(305 mm)
44U
(6.5 ft./1960 mm)
ISO 19 7.25 ft.
(2200 mm)
24 in.
(600 mm)
24 in.
(600 mm)
47U
(6.85 ft./2089 mm)

Artemis Site Preparation and Rack
Installation

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 4-5

The loading of a fully equipped rack is 7.35 kn/m
2
, or 55.35 kn/ft.
2
.


NOTES:
Not all Artemis platforms can be installed in all types of racks.
This section includes a general list of the rack options
available. The installation instructions for each platform
include a list of the racks appropriate for that platform.
The installation instructions in this manual are written on the
basis of an installation using an ECI Telecom enhanced rack.
Some of these instructions may not be relevant if you are
using a standard rack supplied by other vendors.
Before any installation plan can be completed, a site survey by
ECI Telecom technical support team is required to verify rack
accessibility and accessory compatibility at that site. If you are
working with standard racks from other vendors, the site
survey is also essential to determine what changes are required
to adapt the rack to Artemis platform installation
requirements.

All ECI Telecom Artemis equipment racks may be installed on wooden,
concrete, or suspended floors, or suspended from overhead mountings. Some of
these installation options are described in Installing Equipment Racks. If your
facility uses a different installation paradigm, contact the ECI Telecom
Technical Support team for additional information.
Preparing Cables and Fibers


NOTE: This section provides information for preparing cables
and optical fibers. The necessary cables can also be ordered from
ECI Telecom. For details, contact ECI Telecoms Customer
Support team or your ECI Telecom sales representative.

The main cables required for installing the Artemis include:
Grounding cables
Optical fibers
Some of these cables are supplied by ECI Telecom as part of the Artemis
equipment, while others must be prepared on site or ordered separately from
ECI Telecom.


WARNING: Only qualified trained personnel may prepare the
various cable types. Personnel must only use approved
procedures in accordance with the applicable workmanship
practice.
Site Preparation and Rack
Installation
Artemis

4-6 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Grounding Cables


NOTE: Although the Artemis shelves are fully passive, racks
in which they are installed must always be grounded because
equipment connected to power sources, like test equipment,
may operate in them.

Equipment installed in racks is bonded through the screws used to fasten the
equipment chassis to the frame of the rack. Therefore, it is necessary to provide
a reliable low-impedance connection between the rack frame and the site
grounding bus using copper conductors.
Make the connection between the rack grounding screw and the site grounding
bar by means of a copper lead with green/yellow insulation having the same
diameter as the power source input power cable or thicker, in compliance with
UL/ETSI recommendations.
The end of the lead connected to the power source, as used in the rack, must be
terminated in an M8 lug.
Route grounding conductors along the shortest possible route. Treat the bare
portion of the conductor with antioxidant and connect a listed two-hole
compression lug. If the lug is not plated, bring it to a bright finish and coat it
with antioxidant before connecting it to the frame of the rack.
Optical Fibers
Optical fibers can be prepared on site. Use only 2 mm optical fibers to connect
to optical interfaces. For each optical interface, ECI Telecom supplies patch
cords with mating optical connectors already attached to the fiber. Therefore,
only the optical termination on the other side, which is installation-dependent,
must be installed on site.
The optical fibers should enter the rack from the top, be threaded through cable
guides running along the rack side rails, and end at the spooler unit. The
spooler must contain enough fiber length for extracting modules from the
Artemis shelves and for replacing fiber in case of damage (splicing repairs).
When routing fibers, make sure to observe the minimum bending radius (35
mm).
Artemis Site Preparation and Rack
Installation

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 4-7

Equipment Installation
The following sections provide general instructions for the installation of the
Artemis and auxiliary equipment.
The procedures for equipment replacement and upgrades are similar to those
described for installation of the equipment, and when relevant, notes regarding
live replacement or upgrade are inserted in these procedures.
The information appearing in these sections should be used in conjunction with
specific site installation plans in the particular customer network. If you are
interested in obtaining design or installation assistance from ECI Telecom
Network Solutions Divisions Customer Support team or want to prepare a
network installation plan, contact your ECI Telecom sales representative.
Preliminary Preparations
The installation procedures provided in this chapter assume that:
The sites at which the installation procedures are carried out comply with
the requirements listed in Site Preparation and Rack Installation (page 4-1).
The preliminary preparations specified in Before You Start/Safety
Guidelines (page 3-1) have been completed.
Before you start, determine what equipment is to be installed in the rack by
referring to the site installation plan, and note the exact position of each unit.
To avoid errors, it is recommended that you mark the prescribed positions on
the rack rails using a soft pencil.
Site Preparation and Rack
Installation
Artemis

4-8 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Rack Installation
Installing Equipment Racks


NOTE: The instructions in this section are relevant to the
installation of all rack types. However, it is recommended that
Artemis shelves be installed in ETSI A racks.
Rack Floor Marking
You need to mark out the rack floor plan before installing the rack.
Before you start:
Before starting, find the prescribed location of each equipment rack.
If you have not yet unpacked the rack and the associated mounting kits, do so
now (see Unpacking and Performing Visual Inspection).
To mark out the rack floor plan:
1. For each rack, mark out the floor at the rack location(s) according to the
floor plan template corresponding to the type of rack being installed:
ETSI A racks: Use template of diagram a. of Mounting diagrams for
ETSI racks (page 4-10).
23 in. rack: Use template of diagram a. of Mounting diagrams for 19"
and 23" racks (page 4-11).
19 in. rack: Use template of diagram b. of Mounting diagrams for 19"
and 23" racks (page 4-11).
The marked locations are a helpful guide for positioning the racks.
2. If the installation is located at a site with a floating (suspended) floor, also
mark out all cable entry slots.
3. For concrete or wooden floors, mark out all the points designated for
equipment bolting.
Artemis Site Preparation and Rack
Installation

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 4-9

Rack Installation on Concrete Floors
This section describes how to install racks on concrete floors.
To mount the rack on a concrete floor:
1. Drill the required mounting holes in accordance with the appropriate
template (diagram a. of Mounting diagrams for ETSI racks (page 4-10)
diagram a. or b. of Mounting diagrams for 19" and 23" racks (page 4-11)).
2. Insert expansion shields into the holes.
3. Position the rack over the mounting holes.
4. Secure the rack to the floor with the bolts supplied in the mounting kit, in
accordance with diagram b. of Mounting diagrams for ETSI racks, or
diagram c. of Mounting diagrams for 19 in. and 23 in. racks.
Rack Installation on Wooden Floors
This section describes how to install racks on wooden floors.
To mount the rack on a wooden floor:
1. Drill the required mounting holes in accordance with the appropriate
template (see the following figures), using a 5-mm drill bit.
2. Position the rack over the mounting holes.
3. Secure the rack to the floor using the appropriate wood screws (see the
following figures).
Site Preparation and Rack
Installation
Artemis

4-10 ECI Telecom Ltd. Proprietary 407506-2901-023-A00


Figure 4-1: Mounting diagrams for ETSI racks

Artemis Site Preparation and Rack
Installation

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 4-11

a. 23 wide bay mounting hole drilling template
6-1/2 9-29/32
18-1/2
25-7/8
1-45/64
3-11/16
12 mm - 4 places
c. Bolting diagram concrete floor
SCREW M12X50
FLAT WASHER
SPACER
FLOOR LEVEL
M12 EXPANSION SHIELD
b. 19 wide bay mounting hole drilling template
6-1/2 9-29/32
14-1/2
21-7/8
1-45/64
3-11/16
SQUARE WASHER
ANCHOR BRACKET
UNEQUAL FLANGE RACK
4 STAGE
OPEN DUCT
12 mm - 4 places

Figure 4-2: Mounting diagrams for 19" and 23" racks
Site Preparation and Rack
Installation
Artemis

4-12 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Rack Installation on Floating (Suspended)
Floors
This section describes how to install racks on floating (suspended) floors.
To mount the rack on a floating (suspended) floor:
1. Drill the required mounting holes in the suspended floor in accordance with
the appropriate template.
2. Position the rack over the mounting holes.
3. Secure the rack to the floor in accordance with diagram c. of Mounting
diagrams for ETSI racks (page 4-10).
Suspended Overhead Tray Assembly
This section describes how to install racks on a suspended overhead tray.
To mount the rack on a suspended overhead tray:
1. Refer to the suspended overhead tray diagram (see the following figure)
and position the overhead rack securing brackets.
2. Secure the rack to the overhead cabling trays, using the adjustable brackets.
2200 mm high racks may also be attached to the ceiling; 2600 mm racks
are generally attached only to the ceiling.

Figure 4-3: Rack mounting diagram for attachment to suspended overhead
tray (2200 mm rack)
Artemis Site Preparation and Rack
Installation

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 4-13

Installing Extendable Rails
In high-density installations, it may be necessary to install the xRAP above the
rack using the extendable installation rails available from ECI Telecom.
In this case, attach the extendable installation rails to the top of the rack before
installing the equipment.
Rack Grounding
Immediately after installing the rack, connect its grounding stud to the
prescribed grounding point on the site grounding bar. Use a grounding lead that
meets the Rack grounding requirements listed in section Before You Start.
19 in. Rack Installation
The Artemis can also be installed in European 19 in. racks. This is accepted
under the limitations that the rack's general dimensions are according to the
following figure. Any other European 19 in. rack must first be examined and
approved by ECI Telecoms Network Solutions Division Mechanical
Department.

Figure 4-4: Example of an approved European 19" rack
Site Preparation and Rack
Installation
Artemis

4-14 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Installing Ancillary Units in
Racks
ECI Telecom offers various accessories for efficient installation of equipment
in racks. Contact ECI Telecoms Customer Support team or your ECI Telecom
sales representative if you need custom modifications to standard items or
additional items.
This section includes instructions for the installation of ancillary units. The
same units are used in Optical ETSI, ETSI A and ETSI B racks. The
installation procedures for the units used in these rack types are identical. The
specific units you will need to install depend on your site installation plan and
may include one or more of the following:
Spooler unit
Cable/Fiber guide
Above/Below fiber guide
In general, ancillary units are attached to the rack side rails by four M6 Philips
screws. No preparation is required before installation. The following sections
provide mechanical installation instructions for units that require additional
procedures. Skip sections that are not relevant to your particular application.
Installing the Cable/Fiber Guide
The Fiber/Cable guide is supplied for installation above or below the Artemis
shelf and with default ETSI or IEC 19" brackets according to the order. If the
fiber guide is to be installed in a rack type it is intended for, it can be installed
directly in the rack without any workaround. If it is to be installed in a different
rack type, first adapt it with the corresponding kit.
ECI Telecom offers adapter spacer kits and bracket kits for installing the
Cable/Fiber guide in ANSI 19" or 23". If the guide has to be installed in these
rack types, make sure to order the appropriate kit from ECI Telecom. Remove
the default brackets and attach the ANSI brackets to the guide in the
corresponding position (for 19" or 23").
To prepare the IEC 19" Cable/Fiber guide for ANSI 19" rack
installation:
1. Identify the prescribed location of the Cable/Fiber guide in the rack.
2. Take a spacer from the installation kit and screw it into the rack.
3. Repeat Step 2 to attach the other three spacers to the prescribed location on
the rack.
4. Place the Cable/Fiber guide on the spacers and attach it to the rack with
four screws from the installation kit.
Artemis Site Preparation and Rack
Installation

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 4-15

To prepare the ETSI Cable/Fiber guide for ANSI 23"rack
installation:
1. Identify the prescribed location of the Cable/Fiber guide in the rack.
2. Take the appropriate bracket from the installation kit and attach it to the
right side of the Cable/Fiber guide with two screws, washers, and nuts from
the installation kit.
3. Take the appropriate bracket from the installation kit and attach it to the left
side of the Cable/Fiber guide with two screws, washers, and nuts from the
installation kit.
4. Place the Cable/Fiber guide on the prescribed location and attach it to the
rack with four screws from the installation kit
Installing the Above/Below Fiber Guide
The Above/Below fiber guide can be installed above or below the Artemis
shelf according to the fiber route requirements. The fiber guide is supplied by
default with brackets for installation in ETSI, or IEC 19" racks.
ECI Telecom offers adapter spacer kits and bracket kits for installing the
Above/Below fiber guide in ANSI 19" or 23". If the fiber guide is to be
installed in these rack types, make sure to order the appropriate kit from ECI
Telecom. Remove the default brackets and attach the ANSI brackets to the
guide in the corresponding position (for 19" or 23").
To prepare the IEC 19" Above/Below fiber guide for ANSI
19" rack installation:
1. Identify the prescribed location of the Above/Below fiber guide in the rack.
2. Take a spacer from the installation kit and screw it into the rack.
3. Repeat Step 2 to attach the other three spacers to the prescribed location on
the rack.
4. Place the Above/Below fiber guide on the spacers and attach it to the rack
with four screws from the installation kit.
Site Preparation and Rack
Installation
Artemis

4-16 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

To prepare the ETSI Above/Below fiber guide for ANSI
23"rack installation:
1. Identify the prescribed location of the Above/Below fiber guide in the rack.
2. Take the appropriate bracket from the installation kit and attach it to the
right side of the Above/Below fiber guide with two screws, washers, and
nuts from the installation kit.
3. Take the appropriate bracket from the installation kit and attach it to the left
side of the Above/Below fiber guide with two screws, washers, and nuts
from the installation kit.
4. Place the Above/Below fiber guide on the prescribed location and attach it
to the rack with four screws from the installation kit.
Installing the Spooler Unit
The spooler unit is supplied by default with reversible ETSI brackets that can
also be used for installation in IEC 19" racks. The ETSI brackets must be
removed from the spooler, reversed, and reattached for use in 19" racks.
ECI Telecom offers another reversible bracket kit for installing the spooler in
19" or 23" ANSI (open frame) racks. In case the spooler has to be installed in
these rack types, make sure to order the kit from ECI Telecom. The default
brackets must be removed and the ANSI brackets attached to the spooler in the
corresponding position (for 19" or 23").
To prepare the spooler unit for IEC 19" rack installation:
1. Open the four screws attaching the brackets to the spooler; keep the screws.
2. Reverse the brackets and reattach them to the spooler in the position for
IEC 19" rack.
To prepare the spooler unit for 19" or 23" ANSI rack
installation:
1. Open the four screws attaching the brackets to the spooler.
2. Take the 19"/23" ANSI brackets from the installation kit.
3. Identify the required position of the brackets according to the application
(19" or 23").
4. Attach the brackets to the spooler in the corresponding position.
To install the spooler in the rack:
Install the spooler in the rack in the prescribed position and fasten it to the
side rails of the rack with four screws.


407506-2901-023-A00 ECI Telecom Ltd. Proprietary 5-1

In this chapter:
Artemis Shelves Installation Options .............................................................. 5-1
Installing Modules in Artemis-1P and Artemis-2P ......................................... 5-8
Configuring the Artemis-2PE and Installing Modules .................................. 5-15
Routing and Connecting Optical Fibers ........................................................ 5-25
Artemis Shelves Installation
Options
Artemis shelves can be installed in ETSI, IEC 19", and ANSI 19" and 23"
racks. These racks can be installed on wooden, concrete, or suspended floors,
or suspended from overhead mountings. An example of an approved 19" rack
and rack installation procedures are given in Rack Installation (page 4-8).
You can install up to three Artemis shelves in ETSI A racks.
If necessary, contact ECI Telecom's Customer Support team or your ECI
Telecom sales representative for help in meeting your specific installation
requirements.
5
Installing Shelves and
Modules
Installing Shelves and Modules Artemis

5-2 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

A general view of an Artemis shelf with accessories installed in a rack is shown
in the following figure.

Figure 5-1: Artemis shelf with accessories installed in a rack
Artemis Installing Shelves and Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 5-3

Typical Artemis Installation
The typical installation differs according to the Artemis shelf size:
For Artemis-1P, which typically includes a low fiber count, additional
equipment installed in the rack includes:
One Above/Below fiber guide installed above or below the shelf.
One spooler unit installed above or below the Above/Below fiber guide.
A typical installation of the Artemis-1P in a rack is shown in the following
figure.

Figure 5-2: Artemis-1P typical installation in a rack
Installing Shelves and Modules Artemis

5-4 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

additional equipment installed in the rack with the Artemis-2P/E shelf
includes:
One Fiber/Cable guide installed above or below the shelf.
One spooler unit installed above or below the Fiber/Cable guide.
A typical installation of the Artemis-2P/E in a rack is shown in the following
figure.

Figure 5-3: Artemis-2P/E typical installation in a rack
Artemis Installing Shelves and Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 5-5

Preparing the Artemis-1P or Artemis-2P/E
for installation in ETSI and ANSI 23" racks
Before you start:
By default, the Artemis shelves are supplied with two installation kits, one for
ETSI/23" ANSI racks and the other for 19" ANSI racks. The ETSI/23" ANSI
kit includes reversible brackets that can be used for installation in ETSI or 23"
ANSI racks, by attaching the corresponding part of the bracket to the Artemis
shelf. Use the ETSI/23" ANSI kit from the supplied parts for this installation.



NOTES:
The Artemis-2P and Artemis-2PE have identical dimensions
and differ mainly in the high flexibility of slot configuration
in the later. The marking Artemis-2P/E will be used to
description is valid for both.
The installation of the Artemis-1P and Artemis-2P/E shelves
is very similar. The following sections describe the
Artemis-2P/E installation only.
To prepare the Artemis-2P/E for installation in an ETSI
rack:
1. Identify the wide part of the reversible brackets in the installation kit
according to the following figure.

Figure 5-4: Attaching ETSI brackets to the Artemis-2P/E
2. Attach the wide part of the brackets to the Artemis-2P/E with six screws
(three on each side), as shown in the preceding figure.
3. Fasten the brackets to the shelf with the screws.
Installing Shelves and Modules Artemis

5-6 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

To prepare the Artemis-2P/E for installation in a 23" ANSI
rack:
1. Identify the narrow part of the reversible brackets in the installation kit
according to the following figure.

Figure 5-5: Attaching 23" ANSI brackets to the Artemis-2P/E
2. Attach the narrow part of the brackets to the Artemis-2P/E with six screws
(three on each side), as shown in the preceding figure.
3. Fasten the brackets to the shelf with the screws.
Artemis Installing Shelves and Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 5-7

Preparing the Artemis-1P or Artemis-2P/E
for installation in ANSI 19" racks
Before you start:
By default, the Artemis shelves are supplied with two installation kits, one for
ETSI/23" ANSI racks and the other for 19" ANSI racks. Use the 19" ANSI kit
from the supplied parts for this installation.


NOTE: The installation of the Artemis-1P and Artemis-2P/E
shelves is very similar. The following sections describe the
Artemis-2P/E installation only.
To prepare the Artemis-2P/E for installation in an ANSI 19"
rack:
1. Take the ANSI 19" brackets from the installation kit and attach them to the
Artemis-2P/E with six screws (three on each side), as shown in the
following figure.

Figure 5-6: Attaching ANSI 19" brackets to the Artemis-2P
2. Fasten the brackets to the shelf with the screws.
Installing Shelves and Modules Artemis

5-8 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Installing the Artemis-1P or Artemis-2P/E in
a rack
To install the Artemis-1P or Artemis-2P/E shelf in a rack:
1. Identify the prescribed location of the shelf in the rack.
2. Attach the shelf to the rack side rails, using four screws from the
installation kit.
3. Fasten the shelf to the rack.
Installing Modules in Artemis-1P
and Artemis-2P
This section describes the installation of the Artemis Modules (page 2-1) in
Artemis-1P and Artemis-2P shelves.
Installing a Single Slot Module
The following procedure can also be used to replace modules in an operating
shelf, provided the general safety precautions listed in General Safety
Requirements (page 3-1) and the module specific warnings listed for each
module are strictly followed.
The installation of a single slot module in the Artemis-1P or Artemis-2P is very
similar and therefore described only for the Artemis-2P.
Single slot modules can be installed in both Artemis-1P and Artemis-2P.
Artemis Installing Shelves and Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 5-9

Before you start:
Make sure that all modules specified for installation in the shelf in accordance
with the shelf installation plan are available.
When inserting a module, make sure to carefully align it with the modules
guide rails. Hold the module straight during insertion and removal, and pull or
push it slowly and carefully to avoid touching components located on adjacent
modules.

Figure 5-7: Installing a single slot module in an Artemis shelf
To install a single slot module in the shelf:
1. Check that the single slot module has not been physically damaged during
shipment, and that the antistatic protection bag of the original packaging is
sealed.
2. Remove the single slot module from its antistatic protection packaging and
perform a visual inspection to detect damage during shipping. Report any
problems.
3. Hold the single slot module handle and insert its rear end into the module
guides.
4. Push the module in until the front of the module is flush with the front of
the shelf. If resistance is felt, pull the module out and repeat the procedure.
5. Secure the module in place by tightening its two captive screws.
Installing Shelves and Modules Artemis

5-10 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Configuring a Single Slot as Two Mini-Slots
In their default configuration, the Artemis-1P has two single slots and the
Artemis-2P four single slots. Each single slot in the Artemis-1P and in the
upper section only of the Artemis-2P can be divided into two mini-slots, using
a mechanical divider bracket kit.


NOTE: The lower single slots of the Artemis-2P cannot be
configured as mini-slots.

This section explains how to configure a single slot as two mini-slots. The
procedure is very similar in both shelves and is described only for the
Artemis-2P.
Before you start:
Make sure that the divider bracket kit is available in the required quantity for
the mini-slot configuration.
To configure a single slot as two mini-slots:
1. Identify the pin guide at the rear of the divider bracket according to the
following figure.

Figure 5-8: Divider bracket identification
Artemis Installing Shelves and Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 5-11

2. Identify the single slot to be divided.
3. Identify the divider bracket's intended location in the shelf. This location is
indicated by four screw holes in the shelf's frame (see the following figure).

Figure 5-9: Installing a divider bracket
4. Hold the divider bracket opposite the four holes and carefully insert it into
the shelf, taking care that the pin guide is inserted into the corresponding
hole at the back of the shelf, as illustrated in the preceding figure.
5. Fasten the bracket to the shelf with four screws from the divider bracket
installation kit.
Installing a Mini-Slot Module in the Shelf
The following procedure can also be used to replace modules in an operating
shelf, provided the general safety precautions listed in General Safety
Requirements (page 3-1) and the module specific warnings listed for each
module are strictly followed.
The installation of a mini-slot module in the Artemis-1P or Artemis-2P is very
similar and therefore described only for the Artemis-2P shelf.
Mini-slot modules can be installed in the Artemis-1P or in the upper section
(only) of the Artemis-2P, provided the corresponding slot was configured as a
mini-slot.
Installing Shelves and Modules Artemis

5-12 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Before you start:
Make sure that all the modules specified for installation in theArtemis-1P or
Artemis-2P shelf in accordance with the shelf installation plan are available.
When inserting a module, make sure to carefully align it with the modules
guide rails. Hold the module straight during insertion and removal, and pull or
push it slowly and carefully to avoid touching components located on adjacent
modules.

Figure 5-10: Installing a mini-slot module in an Artemis shelf
To install a mini-slot module in the shelf:
1. Check that the mini-slot module has not been physically damaged during
shipment, and that the antistatic protection bag of the original packaging is
sealed.
2. Remove the mini-slot module from its antistatic protection packaging and
perform a visual inspection to detect damage during shipping. Report any
problems.
3. Hold the mini-slot module handle and insert its rear end into the module
guides.
4. Push the module in until the front of the module is flush with the front of
the shelf. If resistance is felt, pull the module out and repeat the procedure.
5. Secure the module in place by tightening its two captive screws.
Artemis Installing Shelves and Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 5-13

Configuring Two Single Slots as a Double
Slot
In its default configuration, the Artemis-1P has two single slots. These slots can
be configured as a double slot, to enable the installation of a double slot
module in the shelf. The configuration is performed by removing the bracket
between the two slots.


NOTE: The configuration of two single slots as a double slot
is supported only in the Artemis-1P.

This section explains how to configure two single slots as a double slot.
To configure two single slots as a double slot:
1. Identify the two single slots and the divider bracket in the Artemis-1P
according to the following figure.

Figure 5-11: Removing the divider bracket from the Artemis-1P
2. Open the four screws fastening the bracket to the Artemis-1P (see the
preceding figure).
3. Remove the bracket from the shelf.
Installing Shelves and Modules Artemis

5-14 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Installing a Double Slot Module
The following procedure can also be used to replace modules in an operating
shelf, provided the general safety precautions listed in General Safety
Requirements (page 3-1) and the module specific warnings listed for each
module are strictly followed.


NOTE: Installation of double slot modules is supported only
in the Artemis-1P.
Before you start:
Make sure that the module specified for installation in the shelf in accordance
with the shelf installation plan is available.
When inserting a module, make sure to carefully align it with the modules
guide rails. Hold the module straight during insertion and removal, and pull or
push it slowly and carefully.

Figure 5-12: Installing a double slot module in the Artemis-1P shelf
To install a double slot module in the shelf:
1. Check that the double slot module has not been physically damaged during
shipment, and that the antistatic protection bag of the original packaging is
sealed.
2. Remove the double slot module from its antistatic protection packaging and
perform a visual inspection to detect damage during shipping. Report any
problems.
3. Hold the double slot module handle and insert its rear end into the module
guides.
Artemis Installing Shelves and Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 5-15

4. Push the module in until the front of the module is flush with the front of
the shelf. If resistance is felt, pull the module out and repeat the procedure.
5. Secure the module in place by tightening its two captive screws.

Figure 5-13: Artemis-1P with a double slot module installed
Configuring the Artemis-2PE and
Installing Modules
The Artemis-2PE features a highly flexible structure that enables you to
configure different slots (single, mini) in the shelf. Mix of different slots in the
same shelf is supported as well. The following sections describe the structure
of the Artemis-2PE and explain how to configure slots and install Artemis
modules.
The Artemis-2PE comes with a default configuration of a quad slot. The shelf
is designed such that no partition is required between modules installed in the
upper and lower parts. This means that the default configuration is ready for
direct installation of one quad module or two double slot modules.
Installing a Double Slot Module
The following procedure can also be used to replace modules in an operating
shelf, provided the general safety precautions listed in General Safety
Requirements (page 3-1) and the module specific warnings listed for each
module are strictly followed.
Installing Shelves and Modules Artemis

5-16 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Before you start:
Make sure that the module specified for installation in the shelf in accordance
with the shelf installation plan is available.
When inserting a module, make sure to carefully align it with the modules
guide rails. Hold the module straight during insertion and removal, and pull or
push it slowly and carefully.

Figure 5-14: Installing a double slot module in the Artemis-2PE
To install a double slot module in the Artemis-2PE shelf:
1. Check that the double slot module has not been physically damaged during
shipment, and that the antistatic protection bag of the original packaging is
sealed.
2. Remove the double slot module from its antistatic protection packaging and
perform a visual inspection to detect damage during shipping. Report any
problems.
3. Hold the double slot module handles on both sides and insert its rear end
into the module guides.
4. Push the module in until the front of the module is flush with the front of
the shelf. If resistance is felt, pull the module out and repeat the procedure.
5. Secure the module in place by tightening its two captive screws.
Artemis Installing Shelves and Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 5-17

Installing a Quad Slot Module
The following procedure can also be used to replace a module in an operating
shelf, provided the general safety precautions listed in General Safety
Requirements (page 3-1) and the module specific warnings listed for each
module are strictly followed.
Before you start:
Make sure that the module specified for installation in the shelf in accordance
with the shelf installation plan is available.
When inserting a module, make sure to carefully align it with the modules
guide rails. Hold the module straight during insertion and removal, and pull or
push it slowly and carefully.

Figure 5-15: Installing a quad slot module in the Artemis-2PE
To install a quad slot module in the Artemis-2PE shelf:
1. Check that the quad slot module has not been physically damaged during
shipment, and that the antistatic protection bag of the original packaging is
sealed.
2. Remove the quad slot module from its antistatic protection packaging and
perform a visual inspection to detect damage during shipping. Report any
problems.
3. Hold the quad slot module handles on both sides and insert its rear end into
the module guides.
4. Push the module in until the front of the module is flush with the front of
the shelf. If resistance is felt, pull the module out and repeat the procedure.
5. Secure the module in place by tightening its four captive screws.
Installing Shelves and Modules Artemis

5-18 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Artemis-2PE Structure
The Artemis-2PE comes by default without any separating bracket. This
configuration is suitable for installing a quad slot module (like the D_MD_80),
or two double slot modules (D_MD_40). Note that in contrast to the
Artemis-2P there is no partition between modules in the upper and lower parts
of the shelf.
The following figure shows a general view of the Artemis-2PE in its default
configuration.

Figure 5-16: Artemis-2PE default configuration
When installation of single or min-slot modules is required you must first
install divider brackets to form the appropriate slots.
The Artemis-2PE has three positions for installing divider brackets at the upper
side and three at the lower side of the shelf. Each position for an upper bracket
is indicated by two screw holes in the shelf frame. The positions for the lower
brackets are regularly concealed behind covers that must be removed before
installing brackets. Different types of brackets are used to form slots at the
upper and at the lower parts of the shelf. The required configuration is obtained
by installing (or not installing) brackets in these positions.
Artemis Installing Shelves and Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 5-19

The following figure shows a general view of the lower and upper brackets.

Figure 5-17: Lower and upper bracket general view
Each bracket has rails that match corresponding guides in the shelf's frame. The
bracket is attached to the shelf with two screws. Note that the Lower bracket is
higher than the Upper one.
Configuring Slots in the Artemis-2PE Upper
Part
The Artemis-2PE comes with a default configuration of a quad slot (no
brackets installed). Different slot size can be configured by installing brackets
at the upper positions of the shelf. For example if you need to configure two
single slots, you have to install a bracket at the middle position.
Before you start:
Make sure that the upper divider bracket kit is available in the required quantity
for the needed configuration.
Installing Shelves and Modules Artemis

5-20 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

To configure a slot at the Artemis-2PE upper side:
1. Identify the upper bracket according to the following drawing.

Figure 5-18: Upper bracket identification
2. Identify the divider bracket's intended location in the shelf. This location is
indicated by two screw holes in the shelf's frame (see the following figure).

Figure 5-19: Installing an upper bracket
3. Hold the divider bracket opposite the two holes and carefully slide it into
the shelf, taking care that the rails are aligned with the corresponding
guides in the shelf's frame.
4. Push the bracket in and make sure that the pin guide is inserted into the
corresponding hole at the back of the shelf, as illustrated in the preceding
figure.
5. Fasten the bracket to the shelf with two screws from the divider bracket
installation kit.
Artemis Installing Shelves and Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 5-21

Configuring Slots in the Artemis-2PE Lower
Part
The Artemis-2PE comes with a default configuration of a quad slot (no
brackets installed). Different slot size can be configured by installing brackets
at the lower positions of the shelf. For example if you need to configure two
single slots, you have to install a bracket at the middle position.
Before you start:
Make sure that the lower divider bracket kit is available in the required quantity
for the required configuration.
To configure a slot at the Artemis-2PE upper side:
1. Identify the lower bracket according to the following drawing.

Figure 5-20: Lower bracket identification
Installing Shelves and Modules Artemis

5-22 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

2. Identify the divider bracket's intended location in the shelf. This location is
indicated by a cover at the lower part of the shelf (see the following figure).

Figure 5-21: Removing a lower bracket cover
3. Open the two screws fastening the corresponding cover to the shelf and
remove the cover (see the preceding figure). After removing the cover two
screw holes are exposed.

Figure 5-22: Installing a lower bracket
4. Hold the divider bracket opposite the two holes and carefully slide it into
the shelf, taking care that the rails are aligned with the corresponding
guides in the shelf's frame and that the pin guide is inserted into the
corresponding hole at the back of the shelf, as illustrated in the preceding
figure.
5. Fasten the bracket to the shelf with two screws from the divider bracket
installation kit.
Artemis Installing Shelves and Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 5-23

Installing a Single Slot Module in the Shelf
The following procedure can also be used to replace modules in an operating
shelf, provided the general safety precautions listed in General Safety
Requirements (page 3-1) and the module specific warnings listed for each
module are strictly followed.
Before you start:
Make sure that all modules specified for installation in the shelf in accordance
with the shelf installation plan are available.
When inserting a module, make sure to carefully align it with the modules
guide rails. Hold the module straight during insertion and removal, and pull or
push it slowly and carefully.

Figure 5-23: Installing a single slot module in the Artemis-2PE
To install a single slot module in the Artemis-2PE shelf:
1. Check that the single slot module has not been physically damaged during
shipment, and that the antistatic protection bag of the original packaging is
sealed.
2. Remove the single slot module from its antistatic protection packaging and
perform a visual inspection to detect damage during shipping. Report any
problems.
3. Hold the single slot module handle and insert its rear end into the module
guides.
Installing Shelves and Modules Artemis

5-24 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

4. Push the module in until the front of the module is flush with the front of
the shelf. If resistance is felt, pull the module out and repeat the procedure.
5. Secure the module in place by tightening its two captive screws.
Installing a Mini-Slot Module in the Shelf
The following procedure can also be used to replace modules in an operating
shelf, provided the general safety precautions listed in General Safety
Requirements (page 3-1) and the module specific warnings listed for each
module are strictly followed.
The installation of a mini-slot module in the Artemis-2PE is very similar to its
installation in the Artemis-2P shelf.
Before you start:
Make sure that all the modules specified for installation in the Artemis-2PE
shelf in accordance with the shelf installation plan are available.
When inserting a module, make sure to carefully align it with the modules
guide rails. Hold the module straight during insertion and removal, and pull or
push it slowly and carefully to avoid touching components located on adjacent
modules.

Figure 5-24: Installing a mini-slot module in the Artemis-2PE
Artemis Installing Shelves and Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 5-25

To install a mini-slot module in the Artemis-2PE shelf:
1. Check that the mini-slot module has not been physically damaged during
shipment, and that the antistatic protection bag of the original packaging is
sealed.
2. Remove the mini-slot module from its antistatic protection packaging and
perform a visual inspection to detect damage during shipping. Report any
problems.
3. Hold the mini-slot module handle and insert its rear end into the module
guides.
4. Push the module in until the front of the module is flush with the front of
the shelf. If resistance is felt, pull the module out and repeat the procedure.
5. Secure the module in place by tightening its two captive screws.
Routing and Connecting Optical
Fibers
In general, all optical fibers must be routed through the conduits running along
the front supports of the rack in which the Artemis is installed. From the
conduits, the fibers are routed into the spooler unit above the Artemis shelf and
then routed back into the rack's conduits. From the conduits, the fibers are then
passed into the corresponding fiber guide and connected to the LC connector
on the particular Artemis module.
Connecting Fibers to Modules in the
Artemis-1P
All optical fibers in the Artemis-1P are connected to the LC connectors on its
modules.
Before you start:
Before installing the Artemis-1P shelf and modules, all optical fibers must be
routed through the conduits running along the front supports of the rack. From
the conduits, the fibers are routed into the spooler above the Artemis-1P shelf
you are installing.
Obtain the site cabling diagram and the detailed cabling diagrams or tables. If
internal fiber connections are required you also need the internal cabling
diagrams for each platform. Fibers must be labeled according to the cabling
diagrams or tables.
Before installing optical fibers, it is recommended to thoroughly clean their
connectors using an approved cleaning kit.
Installing Shelves and Modules Artemis

5-26 ECI Telecom Ltd. Proprietary 407506-2901-023-A00


CAUTION: Make sure that all the optical connectors are
closed at all times by the appropriate protective caps or by the
mating cable connector. Do not remove the protective cap
until an optical fiber is connected to the corresponding
connector, and immediately install a protective cap after a
cable is disconnected.
The minimum bending radius of optical fibers is 35 mm (1.4
in.). Sharp bending of fibers may degrade the optical
transmission characteristics.

The following figure shows the fiber routing for a typical Artemis-1P
installation.

Figure 5-25: Fiber route for Artemis-1P installation
Artemis Installing Shelves and Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 5-27

To route an optical fiber to the desired location on an
Artemis-1P:
1. Slowly pull the fiber end from the conduit and route it to the spooler unit.
2. Wrap the required spare fiber around the storage posts on the spooler in a
figure 8 pattern.
3. Insert the end of the fiber into the Above/Below fiber guide and pass it on
one of the arched elements.
4. Bring the end of the fiber to the LC connector on the designated module.
Leave some slack to prevent stress.
5. Remove the cover from the module connector and connect the fiber
connector to it.
6. Repeat Steps 1 through 5 for all modules in the Artemis-1P.


NOTE: It is recommended to fasten the bundles of fibers with
Velcro strips. Make sure to avoid stressing the fibers,
especially while bending.
Connecting Fibers to Modules in the
Artemis-2P
All optical fibers in the Artemis-2P are connected to the LC connectors on its
modules.
Before you start:
Before installing the Artemis-2P shelf and modules, all optical fibers must be
routed through the conduits running along the front supports of the rack. From
the conduits, the fibers are routed into the spooler above the Artemis-2P shelf
you are installing.
Obtain the site cabling diagram and the detailed cabling diagrams or tables. If
internal fiber connections are required, you also need the internal cabling
diagrams for each platform. Fibers must be labeled according to the cabling
diagrams or tables.
Before installing optical fibers, it is recommended to thoroughly clean their
connectors using an approved cleaning kit.

Installing Shelves and Modules Artemis

5-28 ECI Telecom Ltd. Proprietary 407506-2901-023-A00


CAUTION: Make sure that all the optical connectors are
closed at all times by the appropriate protective caps or by the
mating cable connector. Do not remove the protective cap
until an optical fiber is connected to the corresponding
connector, and immediately install a protective cap after a
cable is disconnected.
The minimum bending radius of optical fibers is 35 mm (1.4
in.). Sharp bending of fibers may degrade the optical
transmission characteristics.

The following figure shows the fiber routing for a typical Artemis-2P
installation.

Figure 5-26: Fiber route for Artemis-2P installation
Artemis Installing Shelves and Modules

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 5-29

To route an optical fiber to the desired location on an
Artemis-2P:
1. Slowly pull the fiber end from the conduit and route it to the spooler unit.
2. Wrap the required spare fiber around the storage posts on the spooler in a
figure 8 pattern.
3. Insert the end of the fiber into the Fiber/Cable guide and pass it on one of
the arched radius-keeping elements. If the fiber has to be connected to an
inner module, pass it on one of the fixed elements. If it has to be connected
to an outer module, pass it on one of the movable elements.
4. Bring the end of the fiber to the LC connector on the designated module.
Leave some slack to prevent stress.
5. Remove the cover from the module connector and connect the fiber
connector to it.
6. Repeat Steps 1 through 5 for all modules in the Artemis-2P.


NOTE: It is recommended to fasten the bundles of fibers with
Velcro strips. Make sure to avoid stressing the fibers,
especially while bending.



Installing Shelves and Modules Artemis

5-30 ECI Telecom Ltd. Proprietary 407506-2901-023-A00






407506-2901-023-A00 ECI Telecom Ltd. Proprietary 6-1

In this chapter:
Overview ......................................................................................................... 6-1
Data Services Multiplexing ............................................................................. 6-2
Adding/Dropping Wavelengths ....................................................................... 6-3
Passive Optical Modules Complementary Solution for AccessWave ............. 6-4
Expanding CWDM Channels to DWDM ........................................................ 6-5
Single Fiber Application .................................................................................. 6-7
OADM Use as a Mux/DeMux ......................................................................... 6-9
Back-to-Back Connectivity ........................................................................... 6-11
Support for 32-Channel Multiplexing on Day One ....................................... 6-13
Overview
The Artemis passive optical platforms can be used in various multiplexing and
demultiplexing applications, including capacity expansion of a fiber to 40
channels, overlay of new services on existing fibers, single fiber application,
and more. These applications add higher flexibility for customer, allowing
them to consolidate and scale data, video, voice storage, and other services.
This chapter provides information about the applications supported by the
Artemis platforms.
6
Applications
Applications Artemis

6-2 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

Data Services Multiplexing
Carrier Ethernet Switch/Routers (CESR), such as ECI Telecom's SR9700
family product line, enable operators to build a Carrier Ethernet infrastructure
for IP transport over metro networks and provide private and business
customers alike with a variety of services in a more cost-effective way than do
existing technologies. These services include very high bandwidth data
applications, IP telephony, IPTV and VoD (Triple Play) with high quality of
service. CESR platforms that are equipped with colored optical interfaces may
transmit their data on different wavelengths that must be multiplexed in order
to provide connectivity to the network, via an optical ring or point-to-point
link.
The benefit of this solution is the optimized utilization of the existing fiber
infrastructure. In the event that a wavelength carries a full 10 Gbps and there is
a need for more capacity, the customer can add additional data cards that
transmit the data on different wavelengths, each carrying 10 Gbps. This
solution enables the addition of up to 40 channels or a total of 400 Gbps over a
single fiber pair.
ECI's CESR platforms (like SR9700 or SR9200) provide a wide range of Layer
2 capabilities; the Artemis product line accomplishes its WDM capabilities,
enabling the CESR platforms to connect to the physical layer.
The following figure illustrates an example of the Artemis application for
multiplexing data services from SR9700 and SR9200 platforms in ring and
point-to-point topologies.

Figure 6-1: Data services multiplexing
Artemis Applications

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 6-3

The solution can be implemented using the passive optical Artemis's
Mux/DeMux modules in a 1U or 2U shelf. The Artemis platforms are
unmanaged products and can, therefore, be added to any family of these
products. Moreover, the Artemis components need no power supply for their
operation, which makes them ideal for deployment in almost any site. The
Artemis supports applications that require dropping or adding channels in
different locations in the network. In such cases the Artemis's OADM modules
can be used.
Adding/Dropping Wavelengths
In many optical network applications it is often required to drop or/and add
wavelengths at different site locations. The location (indoors or out), available
space for additional equipment, and need for power sources all play a
significant role determining a solution.
It is recommended to use passive OADMs when only several lambdas are
needed and Mux/DeMux modules when a higher wavelength count has to be
handled.
The Artemis, with its small footprint, high density, and no need for power, is
the ideal solution for such applications. An example of using the Artemis to
add/drop channels and enhance the xWDM filter offering is shown in the
following figure.

Figure 6-2: Wavelengths add/drop application
Applications Artemis

6-4 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

The XDM on the left side carries traffic over a long span, using optical power
amplifiers in its module cage. The link passes through a DSLAM site housed in
a street cabinet (Site A). Several wavelengths have to be dropped and others
continue from this site. The simple and cost-effective solution in this case is to
add a 1U or 2U Artemis shelf in the street cabinet. Its OADM modules,
extended temperature range, and lack of power source makes the Artemis
optimal to handle this application.
A similar application that requires adding and dropping several wavelengths is
shown at Site B that has very limited space. Using XDM available slots may be
required in the future to house optical power amplifiers or other active
modules, so they must be used wisely.
The preferred solutions in this case is to install an Artemis shelf at Site C,
which has a small footprint and can accommodate OADMs in a high density,
while saving slot positions in the XDM shelf that may be required for future
expansions.
Another possible use of the Artemis is to increase the XDM filter offering. This
application is shown in Site C. The Artemis shelf is co located with the XDM
and accommodates different passive optical modules (Mux/DeMux, OADMs,
CT filters, etc.) in high density. In this solution we can house many passive
optical modules as possible in the Artemis shelf, sparing the XDM module
slots for future optical amplifiers.
Passive Optical Modules
Complementary Solution for
AccessWave
The Artemis platforms provide a complementary solution for AccessWave
(AW) family products AW-30 and AW-60 for CWDM and DWDM passive
optical modules. The Artemis 1U or 2U shelves are unmanaged products and
can easily be added to the AW-30 or AW-60 for passive components like
Mux/DeMux, OADMs, splitters/couplers, and other filters.

Figure 6-3: Passive optical cards complementary solution for AW
Artemis Applications

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 6-5

Expanding CWDM Channels to
DWDM
The Artemis supports integration of CWDM and DWDM channels on the same
fiber, increasing the available capacity that can be delivered over the existing
equipment and infrastructure. The following section describes the motivation
for offering this application, and its practical implementation.
Some customers are using legacy CWDM equipment installed base and
infrastructure to transmit 8 channels, in the best case. In other cases they utilize
only a few of these channels. The massive growth in data, video, and voice
traffic, driven by the increasing demand from business and private customers
for higher bandwidth to support these services, generates major challenges for
the providers how to handle these demands. They therefore look for ways to
expand their network without the need for additional investments.
Another scenario may involve customers that have leased dark fibers connected
to CWDM equipment that is only partly utilized, and they want to leverage
their investment to supply more services over the same infrastructure without
the need to replace the equipment.
The following figure illustrates the channels available for CWDM applications.

Figure 6-4: CWDM channels
Applications Artemis

6-6 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

The CWDM utilizes 16 channels spread over different bands, eight on the S, C
and L Bands (right side) and 8 on the E and O Bands (left side). The eight right
channels are preferred as they feature better characteristics in terms of
attenuation and bandwidth. Typically, CWDM networks use first the eight right
channels and then the left. As can be seen from the preceding figure, there is an
overlap between two CWDM grid channels in the C Band (1531 nm and 1551
nm) and DWDM channels. The 1531 nm channel overlaps 10 DWDM channels
(Ch. 51-60) and the 1551 nm channel overlaps 12 DWDM channels (Ch.
25-36). This means that by giving up these two channels, the network can
significantly be expanded with 22 DWDM channels, while allowing the
customer to keep use of the remaining 14 CWDM channels.
The practical implementation of this solution is shown in the following figure.

Figure 6-5: Artemis CWDM to DWDM channel expansion
The Artemis components provide an optimal and cost-effective solution for
such applications. It requires the use of two DWDM and one CWDM
Mux/DeMux modules. The 12 DWDM channels according to ITU-T G.694.1
(Ch. 25 to Ch. 36) are connected to a D_MD_H1 module and the other 10
DWDM channels (Ch. 51 to Ch. 60) are connected to a D_DMD_H2 module.
A CWDM Mux/DeMux C_MD_O1 is used to connect the output of the
D_MD_M1 at 1551 nm to the corresponding wavelength input, and the output
of the D_DMD_M2 at 1531 nm to the corresponding port. In addition the other
14 CWDM wavelengths are connected to the C_MD_O1.
Artemis Applications

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 6-7

The C_MD_O1 also has a 1311 nm OSC input that enables optical channel
management. The ratio behind selecting this channel, located in the left
8-channel zone, is to keep the right most channels (with the better
characteristics) for data transmission.
Notice that the solution has a penalty, reflected in the fact that the output signal
encounters additional attenuation by the C_MD_O1.
Single Fiber Application
The Artemis supports bidirectional traffic transmission over a single fiber by
smart utilization of the infrastructure. The following section describes the
motivation for offering this application, and its practical implementation.
Regular communication systems use two fibers, one for transmission and one
for reception. Although single fiber is rarely used, there may be cases that
customers need to connect systems with a single fiber (due to the relatively
high fiber cost in the past).
The following figure shows a regular communication system connected with a
fiber pair. In this system we can transmit the same channels, for example Ch.
21 to Ch. 36, in both directions.

Figure 6-6: Transmission system with a fiber pair
When we use a system connected with a single fiber, we cannot implement the
same solution. If we transmit the same channels in both directions on a single
fiber, they will collide in the fiber and no signals will be received at both ends.
If we choose to transmit odd channels from one side and even channels from
the other, the wavelengths will be able to pass the media from side to side
without colliding.
Applications Artemis

6-8 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

The solution is based on using the Mux/DeMux modules as filters, and the SFP
transmitting and receiving characters. The SFP transmits a very coherent and
clear color wavelength, while its receiver has a wideband character. The
principal scheme of the solutions is shown in the following figure.

Figure 6-7: Transmission system with a single fiber
The even Channels 22, 24, 26, etc. are transmitted from left to right, and the
odd Channels 21, 23, 25 etc. from right to left. For example, Ch. 22 is
transmitted from left to right. The corresponding SFP in the right Mux/DeMux
is set for channel 21 but is able to receive Ch. 22 due to the wideband character
of its receiver. This means that, even though the SFP is formally intended for
Ch. 21 it is able to receive Ch. 22. The Mux/DeMux provides a filtering
function for the signal so that the SFP can separate the required signal more
easily. Similarly, Ch. 21 is transmitted from right to left and the corresponding
SFP in the left Mux/DeMux set for channel 22 is able to receive Ch. 22.
The above is a simple solution when no amplifiers are needed. In the event
amplifiers are required, the solution is a little bit complicated as shown in the
following figure.

Figure 6-8: Artemis single fiber application
Artemis Applications

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 6-9

The even channels are transmitted through the left D_MD_H1 Mux/DeMux
from left to right. In the left section, between the output from the Mux and the
fiber we have two branches: the transmit signal is amplified in the upper
amplifier which also blocks the receive signal (in the lower branch), and
connected to a coupler/splitter (C/S). The receive signal arriving from the fiber
passes the left C/S, amplified in the lower amplifier, connected to a DCM, and
enters the DeMux section of the left D_MD_H1. The transmit and receive
signals must be combined in order to pass the single fiber. The C/S acts as a
combiner for this purpose. The odd channels are transmitted through the right
D_MD_H1 Mux/DeMux from right to left in a similar way. The path of the
transmit and receive signals from the right Mux/DeMux to the fiber is also
similar.


NOTE: Each C/S adds additional attenuation of 4 dB, totaling
8 dB for the link.
OADM Use as a Mux/DeMux
The use of Artemis Mux/DeMux is cost-effective for applications with a high
count wavelength. However, when it is necessary to multiplex low count
wavelength (up to four channels), the use of Mux/DeMux grants a costly
solution. A much better cost-effective solution is to use the Artemis OADMs.
The Artemis OADMs are built in East-West technology and can be used as
Mux/DeMux.
This has the following benefits:
The OADM is cheaper than the Mux/DeMux.
The OADM occupies less space (mini-slot) compared to Mux/DeMux
module (one slot).
Holding a single type of module (for example, a 4-channel OADM) in the
inventory for Mux/DeMux and OADM reduces the customer's OPEX cost.
Applications Artemis

6-10 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

The following figure shows the OADM used as a Mux/DeMux for up to four
channels.

Figure 6-9: Artemis OADM use as a Mux/Demux
The add ports are used as the Mux input ports; the Line Out port is used as the
Mux output. The Line In port is used as the DeMux input and the drop ports are
used as the DeMux outputs. The Path-Through (PT) input and output are not
used.
This solution is optimal for up to four channels. When more channels (for
example, eight) have to be multiplexed, customers should add an additional
OADM and use the Pass-Through (PT) ports.


NOTE: When cascading two OADMs, pay attention that the
four channels of the second OADM encounter additional
attenuation due to the PT ports loss.

Artemis Applications

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 6-11


Figure 6-10: Artemis 8-channel multiplexing using two OADMs
Back-to-Back Connectivity
The back-to-back application is used in sites where customers need to open all
wavelengths of a link. The Artemis Mux/DeMux is built in Flat Top
technology that has relatively low attenuation and enables the implementation
of the back-to-back connectivity.
The reasons for a customer to use this application may be part or a combination
of the following:
Several wavelengths have to be regenerated at the site.
Several wavelengths are terminated at the site.
There is a need to split wavelengths to other locations.
Some wavelengths have to be demultiplexed and multiplexed again for
network flexibility.
Applications Artemis

6-12 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

The following figure illustrates the back-to-back application.

Figure 6-11: Artemis back-to-back application
The application also provides a central control point that gives the customer
high flexibility to implement future network changes. It has a significant
advantage compared to the use of OADMs, as it affects less traffic in cases of
changes or maintenance. This application has a penalty of the cumulative
attenuation of two Mux/DeMux compared to an OADM, which is relatively
lower.
Artemis Applications

407506-2901-023-A00 ECI Telecom Ltd. Proprietary 6-13

Support for 32-Channel
Multiplexing on Day One
The Artemis components support the upgrade of a 16-channel Mux/DeMux to
32 channels from day one without affecting traffic. The following figure shows
the solution for this application.

Figure 6-12: 32-channel multiplexing support
The D_MD_H1 and the RB_FLTR are connected at customer's site from day
one, in order to ensure future smooth expansion possibility without affecting
traffic. The customer can connect the 16 first channels to the D_MD_H1
according to his needs. After all channels are connected to the D_MD_H1 and
he needs to expand, he can connect the D_MD_H2 to the RB_FLTR and
additional channels to the M_MD_H2.


NOTE: Ch. 37 to Ch. 44 are not supported in this application.

Applications Artemis

6-14 ECI Telecom Ltd. Proprietary 407506-2901-023-A00



407506-2901-023-A00 ECI Telecom Ltd. Proprietary A-1

In this appendix:
Overview ........................................................................................................ A-1
Physical Specifications ................................................................................... A-6
Environmental Operation Conditions ............................................................. A-7
Standards and References ............................................................................... A-7
Overview
The following chapter contains specifications and additional information for
the Artemis shelves and modules.
CWDM OADMs
The following table lists the CWDM 1-, 2-, and 4-channel OADM modules
specifications.
Table A-1: CWDM 1-, 2-, and 4-channel OADM specifications
Module type
Insertion Loss
Through Drop Add
C_OADM_S (dB) 1.2 1.4 1.4
C_OADM_D (dB) 1.6 1.9 1.9
C_OADM_Q (dB) 2.2 2.4 2.4
Adjacent isolation (dB): -30
Non-adjacent isolation (dB): -40
PDL (dB) 0.25 4-Ch. 0.2 2-Ch. 0.15 1-Ch.
PMD (ps) 0.2
A
Artemis System
Specifications
Artemis System Specifications Artemis

A-2 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

DWDM OADMs
The following table lists the DWDM 1-, 2-, and 4-channel OADM module
specifications.
Table A-2: DWDM 1-, 2-, and 4-channel OADM specifications
Module type
Insertion Loss
Through Drop Add
D_OADM_S (dB) 1 1.4 1.4
D_OADM_D (dB) 1.1A 0.9D 3.1 3.1
D_OADM_Q (dB) 1.1A 0.9D 3.1 3.1
Adjacent isolation (dB): -30
Non-adjacent isolation (dB): -40
PDL (dB) 0.25 4-Ch. 0.2 2-Ch. 0.15 1-Ch.
PMD (ps) 0.2
FOADMs
The following table lists the F_OADM850_xx types and channels.
Table A-3: F_OADM850_xx card types, add/drop, and blocked channels
Card type Add/Drop channels Blocked channels
F_OADM850_21 21, 21.5, 22, 22.5, 23, 23.5, 24 20.5, 24.5
F_OADM850_25 25, 25.5, 26, 26.5, 27, 27.5, 28 24.5, 28.5
F_OADM850_29 29, 29.5, 30, 30.5, 31, 31.5, 32 28.5, 32.5
F_OADM850_33 33, 33.5, 34, 34.5, 35, 35.5, 36 32.5, 36.5
F_OADM850_37 37, 37.5, 38, 38.5, 39, 39.5, 40 36.5, 40.5
F_OADM850_41 41, 41.5, 42, 42.5, 43, 43.5, 44 40.5, 44.5
F_OADM850_45 45, 45.5, 46, 46.5, 47, 47.5, 48 44.5, 48.5
F_OADM850_49 49, 49.5, 50, 50.5, 51, 51.5, 52 48.5, 52.5
F_OADM850_53 53, 53.5, 54, 54.5, 55, 55.5, 56 52.5, 56.5
F_OADM850_57 57, 57.5, 58, 58.5, 59, 59.5, 60 56.5, 60.5
Artemis Artemis System Specifications

407506-2901-023-A00 ECI Telecom Ltd. Proprietary A-3

The following table lists the F_OADM850_xx specifications.
Table A-4: F_OADM850_xx specifications
Module type
Insertion Loss
Through Drop Add
1.0A 0.9D 7 10
Adjacent isolation (dB): -25
Non-adjacent isolation (dB): -30
PDL (dB) 0.3
PMD (ps) 0.5
Table A-5: F_OADM850_xx environmental specifications
Parameter Specification
Operation temperature - 25 - 75 C
Operation humidity 5 - 95 % RH
Storage temperature - 40 ~ + 85 C
Storage humidity 5 ~ 100 % RH
CWDM Mux/DeMux 8-Channel
The following table lists the CWDM Mux/DeMux 8-channel specifications.
Table A-6: CWDM Mux/Demux 8-channel specifications
Module C_MD_O1 C_MD_O2
Insertion loss mux + demux (dB) 2.5M
3.5D
3.5M
3.5D
Return loss (dB) 50 45
Directivity (dB) 50 50
Artemis System Specifications Artemis

A-4 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

DWDM Mux/DeMux FT 16-Ch. Red/Blue
Band, 40-Ch., and 80-Ch. C Band
The following table lists the DWDM Mux/DeMux Flat Top (FT) 16-channel
Red/Blue band and 40-channel C band specifications.
Table A-7: DWDM Mux/Demux FT 16-Ch. Red/Blue band and 40-Ch. C band
specifications
Module D_MD_H1 D_MD_H2 D_MD_40 D_MD_80
Insertion loss mux + demux (dB) 5.5M
5.5D
5.5M
5.5D
6.0 M
6.0 D
6.5M
6.5D
Return loss (dB) 45 45 45
Directivity (dB) -- -- -- --
Coupler/Splitter 50%/50% SM
The following table lists the Coupler/Splitter 50%/50% SM specifications.
Table A-8: Coupler/Splitter 50%/50% SM specifications
Parameter Ch.
Insertion loss (dB) Splitter in - out < 3.7

Coupler in - out < 3.7
Splitter 99%/1% SM
The following table lists the Splitter 99%/1% SM specifications.
Table A-9: Splitter 99%/1% SM specifications
Parameter Ch.
Insertion loss (dB) Splitter in - out 99% < 0.5

Splitter in - out 1% < 21
Artemis Artemis System Specifications

407506-2901-023-A00 ECI Telecom Ltd. Proprietary A-5

C/T Filter 1510 nm Mux/DeMux
The following table lists the C/T Filter 1510 nm Mux/DeMux specifications.
Table A-10: C/T Filter 1510 nm Mux/DeMux specifications
Parameter Ch.
Insertion loss (dB) In C to Line Out < 0.6

In SV to Line Out < 0.9

Line In to Out C < 0.9

Line In to Out SV < 1.8
PMD (ps) PMD < 0.1
Red/Blue Filter
The following table lists the Red/Blue Filter specifications.
Table A-11: Red/Blue Filter specifications
Parameter Ch.
Insertion loss (dB) Line In to Out B < 0.8

Line In to Out R < 1.2

In B to Line Out < 1.2

In R to Line Out < 0.8
PMD (ps) PMD < 0.1
INTRLVR Module
The following table lists the INTRLVR specifications.
Table A-12: INTRLVR specifications
Module type
Insertion Loss
Through Drop Add
1.0A 0.9D < 2.2 < 2.2
Adjacent isolation (dB): > 27
Non-adjacent isolation (dB):
PDL (dB) < 0.5
PMD (ps) < 0.5
Artemis System Specifications Artemis

A-6 ECI Telecom Ltd. Proprietary 407506-2901-023-A00

M-DCF_xx
The M-DCF_xx modules are available for dispersion compensation in several
types according to the distance, where xx designates the distance (nominal
compensation length) in km.
The following section provides the M-DCF_xx modules specifications.
Operating wavelength ........................................................... 1530 nm to 1565 nm
Table A-13: M-DCF_xx specifications
Nominal
compensation
length
Typical dispersion @
1550 nm [ps/nm]
Max. insertion loss [dB] Max. Polarization Mode
Dispersion (PMD) [ps]
5 km -85 1.9 0.22
10 km -170 2.0 0.25
20 km -340 2.6 0.29
30 km -510 3.2 0.35
40 km -680 3.8 0.41
60 km -1020 5.0 0.50
80 km -1360 6.2 0.60
100 km -1700 7.6 0.65
120 km -2040 9.0 0.72
Return Loss:
Connector ................................................................................................ < -45 dB
Fiber ......................................................................................................... < -27 dB
Physical Specifications
Dimensions (H x W x D)
Artemis-1P ........................................................................ 43.4 x 443 x 239.5 mm
Artemis-2P ........................................................................... 88 x 443 x 239.5 mm
Artemis-2PE ........................................................................ 88 x 443 x 239.5 mm
Mini slot module ....................................................................... 35 x 89 x 221 mm
Single slot module .................................................................. 35 x 185 x 237 mm
Double slot module ........................................................... 35 x 376.2 x 253.1 mm
Quad slot module .............................................................. 71 x 376.2 x 253.1 mm
Weight
Artemis-1P ........................................................................................ 6.2 kg (max.)
Artemis-2P ...................................................................................... 10.4 kg (max.)
Artemis Artemis System Specifications

407506-2901-023-A00 ECI Telecom Ltd. Proprietary A-7

Artemis-2PE ..................................................................................... 8.5 kg (max.)
Mini slot module ........................................................................... 0.385 kg (max.)
Single slot module .......................................................................... 1.34 kg (max.)
Double slot module ........................................................................... 1.8 kg (max.)
Quad slot module .............................................................................. 2.3 kg (max.)
Environmental Operation
Conditions
Applicable specification ........................................... ETS 300 019-1-3 Class 3.1E
Temperature range ......................................................................... -5 C to +60 C
Shock/Vibration ....................... Earthquake zone-4 GR-63-CORE, GR-78-CORE
Standards and References
The following is a list of standards and reference documents that relate to the
Artemis family platforms.
1. EN 300 019-1-1 (2003/04): Environmental Engineering (EE);
Environmental Conditions and Environmental Tests for
Telecommunications Equipment; Storage.
2. EN 300 019-1-2 (2003/04): Environmental Engineering (EE);
Environmental Conditions and Environmental Tests for
Telecommunications Equipment; Transportation.
3. ETSI EN 300 019-1-2 (2004/07) Environmental Engineering (EE);
Environmental Conditions and Environmental Tests for
Telecommunications Equipment; Stationary use at weather protected
location.
4. EN 300 132 -2 (2003/03): Environmental Engineering (EE); Power
Supply Interface at the Input to Telecommunications Equipment.
5. EN 300 386 (2003/01): Electromagnetic compatibility and Radio
spectrum Matters (ERM); Telecommunication network equipment;
Electromagnetic Compatibility (EMC) requirements.
6. EN- 60950-ed1 (2001/10) Electrical Safety.
7. ETR 114: Functional Architecture of SDH Transport Networks.
8. FTZ 1 TR9 (2002/06) - Deutsche Telekom A.G. EMC Requirements
9. IEC 60825-1 and IEC 60825-2 Safety of Laser Products.
10. UL- 60950-1 ed2 (2001/10) Electrical Safety.


Artemis System Specifications Artemis

A-8 ECI Telecom Ltd. Proprietary 407506-2901-023-A00