CHAPTER 1
INTRODUCTION TO TELECOMMUNICATION
1.1 DEFINITION OF TELECOMMUNICATION
Telecommunication is the transmission of information over significant distance to
communicate. In earlier times, telecommunications involved the use of visual signals, such as
beacons, smoke signals, semaphore telegraphs, signal flags, and optical heliographs, or audio
messages via coded drumbeats, lung-blown horns, or sent by loud whistles, for example. In
the modern age of electricity and electronics, telecommunications now also includes the use
of electrical devices such as the telegraph, telephone, and teleprinter, as well as the use of
radio and microwave communications, as well as fiber optics and their associated electronics,
plus the use of the orbiting satellites and the Internet.
In modern times, this process almost always involves the sending of electromagnetic waves
by electronic transmitters but in earlier years it may have involved the use of smoke signals.
Today, telecommunication is widespread and devices that assist the process, such as the
television, radio and telephone, are common in many parts of the world. There is also a vast
array of networks that connect these devices, including computer networks, public telephone
networks, radio networks and television networks. Computer communication across the
Internet, such as e-mail and instant messaging, is just one of many examples of
telecommunication.
CDMA is the only one of the three technologies that can efficiently utilize spectrum
allocation and offer service to many subscribers without requiring extensive frequency
planning.
All CDMA users can share the same frequency channel because their conversations are
distinguished only by digital code, while TDMA operators have to coordinate the allocation
of channels in each cell in order to avoid interfering with adjacent channels. The average
transmitted power required by CDMA is much lower than what is required by analog, FDMA
and TDMA technologies.




2

1.2 CLASSIFICATION













Figure 1.1 Classification of Telecommunication

1.2.1 GSM
GSM (Global System for Mobile communication) is a digital mobile telephony system that is
widely used in Europe and other parts of the world. GSM uses a variation of time division
multiple access (TDMA) and is the most widely used of the three digital wireless telephony
technologies (TDMA, GSM, and CDMA). GSM digitizes and compresses data, then sends it
down a channel with two other streams of user data, each in its own time slot.
GSM networks operate in a number of different frequency ranges (separated into GSM
frequency ranges for 2G and UMTS frequency bands for 3G). Most 2G GSM networks
operate in the 900 MHz or 1800 MHz bands. Some countries in the Americas (including
Canada and the United States) use the 850 MHz and 1900 MHz bands because the 900 and
1800 MHz frequency bands were already allocated. Most 3G GSM networks in Europe
operate in the 2100 MHz frequency band.

1.2.2 CDMA
CDMA (Code-Division Multiple Access) refers to any of several protocols used in so-called
second-generation (2G) and third-generation (3G) wireless communications. As the term
Telecommunication
Wireline Wireless
CDMA
GSM
DLC
PRI
BRI
ILL
MPLS
LL
NPLC
3

implies, CDMA is a form of multiplexing, which allows numerous signals to occupy a single
transmission channel, optimizing the use of available bandwidth. The technology is used in
ultra-high-frequency (UHF) cellular telephone systems in the 800-MHz and 1.9-GHz bands.
CDMA employs analog-to-digital conversion (ADC) in combination with spread spectrum
technology. Audio input is first digitized into binary elements. The frequency of the
transmitted signal is then made to vary according to a defined pattern (code), so it can be
intercepted only by a receiver whose frequency response is programmed with the same code,
so it follows exactly along with the transmitter frequency. There are trillions of possible
frequency-sequencing code, which enhances privacy and makes cloning difficult.
The CDMA channel is nominally 1.23 MHz wide. CDMA networks use a scheme called soft
handoff, which minimizes signal breakup as a handset passes from one cell to another. The
combination of digital and spread-spectrum modes supports several times as many signals
per unit bandwidth as analog modes. The original CDMA standard, also known as CDMA
One and still common in cellular telephones in the U.S., offers a transmission speed of only
up to 14.4 Kbps in its single channel form and up to 115 Kbps in an eight-channel form.
CDMA uses a radically different approach. It assigns each subscriber a unique "code" to put
multiple users on the same wideband channel at the same time. Both the mobile station and
the base station, to distinguish between conversations use the codes, called pseudo-random
codes.
Depending on the level of mobility of the system, it provides 10 to 20 times the capacity of
AMPS, and 4 to 7 times the capacity of TDMA.


Figure 1.2 CDMA technique


4








Figure 1.3 CDMA users separated by codes

CDMA is the only one of the three technologies that can efficiently utilize spectrum
allocation and offer service to many subscribers without requiring extensive frequency
planning.
All CDMA users can share the same frequency channel because their conversations are
distinguished only by digital code, while TDMA operators have to coordinate the allocation
of channels in each cell in order to avoid interfering with adjacent channels. The average
transmitted power required by CDMA is much lower than what is required by analog, FDMA
and TDMA technologies.

1.3 CDMA TECHNOLOGY
CDMA technology is most developing technology in nowadays world. Earlier it was only
used for military purpose because of its message security property but now we are using it for
commercial use also. RELIANCE and TATA, both service providers are using this
technology. We are using CDMA technology because of its great advantages which are listed
here under.
CDMA technology has numerous advantages including:
1. Coverage
2. Capacity
3. Clarity
4. Cost
5. Compatibility

Here we will take brief description of each advantage of the CDMA technology:
5

1.3.1 CDMA Coverage
CDMA's features result in coverage that is between 1.7 and 3 times that of TDMA:
Power control helps the network dynamically expand the coverage area.
Coding and interleaving provide the ability to cover a larger area for the same amount
of available power used in other systems.
1.3.2 CDMA Capacity
CDMA capacity is ten to twenty times that of analog systems, and it's up to four times that of
TDMA. Reasons for this include:
CDMA's universal frequency reuse.
CDMA users are separated by codes, not frequencies.
Power control minimizes interference, resulting in maximized capacity.
CDMA's soft handoff also helps increase capacity. This is because a soft handoff
requires less power.

Figure 1.4 Comparison of various techniques
1.3.3 CDMA Clarity
Often CDMA systems can achieve "wire line" clarity because of CDMA's strong digital
processing. Specifically,
The rake receiver reduces errors.
The variable rate vocoder reduces the amount of data transmitted per person, reducing
interference.
The soft handoff also reduces power requirements and interference.
Power control reduces errors by keeping power at an optimal level.
CDMA's wide band signal reduces fading.

6

1.3.4 CDMA Cost
CDMA's better coverage and capacity result in cost benefits:
Increased coverage per BTS means fewer BTS are needed to cover a given area. This
reduces infrastructure costs for the providers.
Increased capacity increases the service provider's revenue potential.
CDMA costs per subscriber have steadily declined since 1995 for both cellular and
PCS applications.
1.3.5 CDMA Compatibility
CDMA phones are usually dual mode. This means they can work in both CDMA systems and
analog cellular systems. Some CDMA phones are dual band as well as dual mode. They can
work in CDMA mode in the PCS band, CDMA mode in the cellular band, or analog mode in
an analog cellular network.

1.4 CDMA WORKING
As the name suggest this technique uses mathematical codes to allow multiple access Instead
of using frequencies or time slots, as do traditional technologies. However, because the
conversations taking place are distinguished by digital codes, many users can share the same
bandwidth simultaneously.
The advanced methods used in commercial CDMA technology improve capacity, coverage
and voice quality, leading to a new generation of wireless networks.
CDMA receivers, conversely, separates communication channels by a pseudo-random
modulation that is applied and removed in the digital domain. Multiple users can therefore
occupy the same frequency band. This universal frequency reuse is crucial to CDMA's
distinguishing high spectral efficiency. Central to the cellular concept is frequency reuse,
which is critically dependent upon the fact that the carrier wave power decreases with
increasing distance. With this information, a cellular division of frequency channels can be
implemented. The channel is allocated to another radio station far enough apart where signals
won't interfere with each other. By reusing channels in multiple cells, the system can grow
without geographical limits.



7



F2
F1 F3
F4
F5 F6
F7





Figure 1.5 Frequency Reuse Pattern-7 Frequency Reuse Pattern-1

CDMA assigns one distinct spreading code to each user. As long as the codes are
orthogonal or almost orthogonal all users can send and receive their signal through
the same wide band channel.
Other users signals appear like noise.
A CDMA system allows multiple access using a single CDMA channel.
The same channel can be used in adjacent cells. Thus CDMA allows a universal reuse
pattern, or reuse of one.
Because of spread spectrum nature of signals all co-channel interference appear like
noise to intended user.
Since different base stations or users use different codes with almost zero correlation,
the receivers can reject co-channel interference as part of De-spreading.

1.5 CDMA BENEFITS
When implemented in a cellular telephone system, CDMA technology offers numerous
benefits to the cellular operators and their subscribers. The following is an overview of the
benefits of CDMA.
Capacity increases of 8 to 10 times that of an AMPS analog system and 4 to 5 times
that of a GSM system.
8

Improved call quality, with better and more consistent sound as compared to AMPS
systems.
Simplified system planning through the use of the same frequency in every sector of
every cell.
Enhanced privacy.
Improved coverage characteristics, allowing for the possibility of fewer cell sites.
1.6 CDMA CODES
As the technology, it is known as spread spectrum technology so for spreading the
information we have to consider some points, they are as followed:
A CDMA signal uses many chips to convey just one bit of information.
Each user has unique pattern, in fact a code channel.
To receive or recover a bit, integrate a large number of chips known by the code
pattern.
Other users code pattern appears random and integrates in a self-canceling fashion;
dont disturb the decoding decision being made with the proper code pattern.
Uplink Identification
On the uplink, the base station uses the long code to identify the mobile unit that is using a
particular CDMA channel. The long code also provides spreading and encryption.
The uplink signal uses the short code for quadrature spreading and to allow the base station
to obtain bit synchronization. The Walsh functions are used on the uplink to provide for
better signal reception through spreading gain.
Downlink Identification
Now consider downlink identification. On the downlink, the mobile unit must identify the
base station as well as the call itself. The following are used on the downlink:
Long code for encryption
Short code for base station identification
Walsh functions for channel assignment




9

1.7 PN CODES
Forward link of IS-95 CDMA has pilot and sync channels to aid synchronization, but the
reverse link does not have pilot and sync channels. Thus, Walsh codes cannot be used on the
reverse link. The incoherent nature of the reverse link calls for the use of another class of
codes, PN codes, for Channelization. PN codes have very sharp autocorrelation.

Generation of PN Codes
PN code sets can be generated from linear feedback shift registers. Binary bits are shifted
through the different stages of the register. The output of the last stage and the output of one
intermediate stage are combined and fed as input to the first stage. The register starts with an
initial sequence of bits, or initial state, stored in its stages. Then the register is clocked, and
bits are moved through the stages. This way, the register continues to generate output bits and
feed input bits to its first stage. The output bits of the last stage form the PN code.
Here we show the code generation using the register Figure 1.6. Let initial state is [1, 0, 1]
for register. The output of stage 3 is the output of the register.








Figure 1.6 PN code generation through shift registers

1.8 HANDOFF IN CDMA
The act of transferring support of a mobile from one base station to another is termed
Handoff. Handoff occurs when a call has to be handed off from one cell to another as the
user moves between cells.

10

Figure 1.7 Handoff between two cells

Types of Handoff
Hard Handoff
Soft Handoff
Handover occurs when a call has to be passed from one cell to another as the user moves
between cells. The connection to the current cell is broken, and then the connection to the
new cell is made. This is known as a "break-before-make" handover. This is also known as
hard hand over. Since all cells in CDMA use the same frequency, it is possible to make the
connection to the new cell before leaving the current cell. This is known as a "make-before-
break" or "soft" handover. Soft handovers require less power, which reduces interference
and increases capacity. Mobile can be connected to more than two BTS at the time of
handover. This is sometimes called "softer" handover.






HARD HANDOFF Figure 1.8 SOFT HANDOFF
Break before make (a) Make-before-break (b)
One of the main advantages of CDMA systems is the capability of using signals that arrive in
the receivers with different time delays. This phenomenon is called multi path. FDMA and
TDMA, which are narrow band systems, cannot discriminate between the multi path arrivals,
and resort to equalization to mitigate the negative effects of multi path.
Due to its wide bandwidth and rake receivers, CDMA uses the multi path signals and
combines them to make an even stronger signal at the receivers. CDMA subscriber units use
11

rake receivers. This is essentially a set of several receivers. One of the receivers constantly
searches for different multi paths and feeds the information to the other three fingers. Each
receiver then demodulates the signal corresponding to a strong multi path. The results are
then combined together to make the signal stronger.
Figure 1.9 Use of Rake receiver
Soft Handoff
This handoff requires the mobile to constantly search for multi paths from different base
stations even while actively receiving and sending traffic. Soft handoff can be costly for
network capacity if not implemented properly, as each base station that the mobile is in
simultaneous contact with must allocate resources for the communications link.
To make Handoff Mobile Station maintains four types of different sets.
Active Set: It contain pilot offset of sector whose channel is currently monitored by
mobile.
Candidate Set: It contain pilot that are not in the active set, but have sufficient signal
strength for demodulation.
Neighbor Set: It contain pilot of base station of neighboring cell that are indicated by
network through paging channel.
Remaining Set: This set contains all pilot offset in system excluding active and
neighbor set.
The active set is the set of base stations that the mobile may be in simultaneous contact. The
base station based on measurement information relayed by the mobile controls this set. The
candidate set entails pilots that are not in the active set but can be successfully demodulated
by the mobile. The maximum number of pilots in either the active or candidate sets is 6.
12

The neighbor set is based on predetermined pilots that are in the vicinity of the base station
or base stations the mobile is currently in contact with. This may have as many as 20 pilots in
it. The remaining set covers all other pilots.
The base station must drop pilots from the active set whose strength has dropped below a
certain threshold, T_DROP. This is also another event that can trigger the mobile to send a
PSMM. Threshold comparisons to drop a pilot are timer based, meaning that the pilot must
be below T-DROP for a certain amount of time (given by T_TDROP) before the pilot is
demoted. In addition, the mobile may search for multi paths at certain PN offsets given the
network deployment. For instance, if the base station knows the PN offsets of neighboring
base stations, it may provide the mobile with search windows.
Hard Handoff
The third is the hard handoff. The CDMA system uses two types of hard handoffs. CDMA-
to-CDMA handoff occurs when the mobile is transitioning between two CDMA carriers (i.e.,
two spread-spectrum channels that are centered at different frequencies). This hard handoff
can also occur when the mobile is transitioning between two different operators systems.
CDMA-to-CDMA handoff is sometimes called D-to-D handoff. On the other hand, CDMA-
to-analog handoff occurs when a CDMA call is handed down to an analog network. This can
occur when the mobile is traveling into an area where there is analog service but no CDMA
service. CDMA-to-analog handoff is sometimes called D-to-A handoff.
Other CDMA Handoff
CDMA uses soft handoff whenever possible because the performance is very much superior
to other forms of handoff. However, there are several forms of handoff that cannot be done
softly.
Inter Frequency Handoff
If there are multiple CDMA carrier frequencies active, then handoffs between them must be
hard. Inter-frequency hard handoffs are probably best accomplished by doing so within one
geographical site, rather than trying to handoff to a neighboring site. The inter-frequency
handoff can first be executed intra-site, where the mobiles timing is already known, followed
immediately by a soft handoff to the neighbor without frequency change on the new
frequency.


13

Softer Handoff
Each BTS sector has unique PN offset & pilot. If multiple sectors of one BTS simultaneously
serve a handset, this is called Softer Handoff.
CDMA Handoff Advantage over AMPS Handoff
It is soft meaning that communication is not interrupted by the handoff. This means
fewer dropped calls for users and higher customer satisfaction for operators.
The handoff is not abrupt, but rather it is a prolonged call state during which there is
communication via two or more base stations. The multi-way communication
diversity improves the link performance during the handoff, the diversity gain
partially compensates for the large path loss at the cell boundary.

















14

CHAPTER 2
DIGITAL TRANSMISSION
2.1 TRANSPORT NETWORK
The network that carries communication and information signals from one place to another
is called the Transport Network.
TABLE 2.1
Comparison between Early & Modern Transmission Network

Modern definition of Transmission network:
The purpose of a transmission network is to multiplex together multiple low bit rate digital
traffic streams into higher bit rate traffic streams for efficient transport between access points.
Medium: Carries signals from one place to another. Eg. air, copper, optical fiber, etc.

2.2 EVOLUTION OF DIGITAL TRANSMISSION NETWORKS
Main principles:
1. Pulse Code Modulation
2. Time Division Multiplexing
3. Standard Multiplexing Hierarchies (E.g. PDH, SDH).

Early Transmission Network

Modern Transmission Network

1. Supports Voice only

2. Analog
3. Covered short distances
4. Operate at very slower speed
5. Could only accommodate few
users.
6. Network availability is not
ensured.

1. Provide multiple services like
digital voice, video and data.
2. digital
3. Cover long distances
4. Operate at very high speed
5. Accommodate millions of users

6. Ensure 99.999% network
availability.

15



2.2.1 Pulse Code Modulation
PCM is the method to convert analog signals into digital signals by means of
sampling according to Nyquist criteria , quantizing and then encoding analog signal
and transmitting it at a bit rate of 64 Kbit/s.
A transmission rate of 2.048 Mbit/s (known as E1) results when 30 such coded
channels are collected together into a frame along with the necessary signaling
information. This so-called primary rate is used throughout the world.
Only the USA, Canada and Japan use a primary rate of 1.544 Mbit/s, formed by
combining 24 channels (known as T1 carrier system) instead of 30.

2.2.2 Time Division Multiplexing
Multiplexing is the assembly of a group of lower bit rate individual channels into a higher bit
rate aggregate.
32 channels x 64Kbps = 2048 Kbps = 2 Mbps

2.2.3 Introduction to E1 Interface
A communication line that was developed by European standards is, that multiplexes thirty
voice channels and two control channels onto a single communication line. The E1 line uses
256 bit frames and transmits at 2.048 Mbps. The E1 interface is independent standardized
TDM technology. This technology enables transmission of several (multiplexed) voice/data
channel simultaneously on the same transmission facility. The E1 standard is mostly
deployed in Europe.


Fig 2.1 E1 frame structure


16









Figure 2.2 A communication network without E1




E1 Link





Figure 2.3 A communication network with E1

Suppose we have 32 channels, each with a rate of 64Kbs that we wish to transfer to the other
end. The multiplexing takes from each of the 32 lines a single byte and sends then one after
the other. After doing so; it takes the next byte from every channel, and so on. The

Phone
System
FAX
FAX

PC

PC

Phone
System

Phone
System

Phone
System
FAX FAX

PC

PC

M
U
X

M
U
X

17

multiplexer must be able to send all the 32*8 bits from the 32 channels without the second
byte of the first channel getting lost.
This implies that output rate of the multiplexer should be at least 32*64 Kbps or 2048Kbps.
This method is called Time Division Multiplexing (TDM). Because the multiplexer took
there 1/8000 second for transferring a single byte of a single channel, and divided it between
the 32 channels by increasing the rate so that each byte of a channel will take 1/ (8000*32)
second to send.

2.2.4 Multiplexing Hierarchies
Traffic over the past decade has demanded that more and more of these basic E1s be
multiplexed together to provide increased capacity.
PDH (Plesionchronous Digital Hierarchy):
As bandwidth demand grew, the technology called Plesionchronous Digital Hierarchy
(PDH) was developed by ITU-T G.702, whereby the basic primary multiplexer 2.048 Mb/s
trunks were joined together by adding bits (bit stuffing) which synchronized the trunks at
each level of the PDH. This hierarchy is based on multiples of 4 E1s.
E2, 4 x E1 - 8Mb/s
E3, 4 x E2 - 34Mb/s
E4, 4 x E3 - 140Mb/s
E5, 4 x E4 - 565Mb/s
18


Figure 2.4 PDH (Plesionchronous Digital Hierarchy)
Limitations of PDH:
Data sources are nominally synchronous.
Tributary signals can only be accessed at the level from which they were multiplexed.
The use of Justification bits (added bits which tell the multiplexers which bits are
data and which are spare) at each level at PDH, means that identifying the exact
location of the frames from a single 2 Mb/s line within a 140 Mb/s channel is
impossible.
In order to access a single 2 Mb/s line, the 140 Mb/s channel must be completely de-
multiplexed to its 64 constituent 2 Mb/s lines via 34 and 8Mb/s.
Once the required 2 Mb/s has been identified and extracted, the channels must be then
be re-multiplexed back up to 140 Mp/s for onward transmission.
SDH (Synchronous Digital Hierarchy):
As management in PDH is very inflexible, SDH was developed. Synchronous Digital
Hierarchy (SDH) originates from Synchronous Optical Network (SONET) in the US.
Telecommunications technologies are generally explained using so called layer models. SDH
can also be depicted in this way. SDH networks are subdivided into various layers that are
directly related to the network topology.
19

The lowest layer is the physical layer, which represents the transmission medium. This is
usually a glass fiber or possibly a radio-link or satellite link. The regenerator section is the
path between regenerators. Part of the overhead (RSOH, regenerator section overhead) is
available for the signaling required within this layer.
The remainder of the overhead (MSOH, multiplex section overhead) is used for the needs of
the multiplex section. The multiplex section covers the part of the SDH link between
multiplexers.






Fig 2.5 SDH layer model
The carriers (VC, virtual containers) are available as payload at the two ends of this section.
The two VC layers represent a part of the mapping process. Mapping is the procedure
whereby the tributary signals, such as PDH and ATM signals are packed into the SDH
transport modules. VC-4 mapping is used for 140 Mbit/s or ATM signals and VC-12 mapping
is used for 2 Mbit/s signals.

2.3 SDH FRAME STRUCTURE
STM-1 frame
In SDH the basic rate is 155.52 Mb/s. This is called the Synchronous Transport Module
Level 1(STM-1). Higher rates are designated by STM-M where values of M by the ITU-T
recommendations are M=1, 4, 16 and 64.
Overheads bytes (first 3*3 columns of frame) carry Network Management
Information such as:
Trail Trace - misconnection of the physical media most common
Error Monitoring
Automatic Protection Switching
Framing, Multiplexing

20


Fig 2.6 SDH STM-1 Frame Format

Synchronous Payload Envelope (SPE) (261(87*3) columns) carry User Data i.e.
PDH frames plus 27(9*3) bytes of path overhead.
Path overhead
In transmission, a path is defined as a circuit joining two nodes that may pass trough a
number of intermediate nodes. In SDH, extra capacity is reserved to carry monitoring and
management information associated with the path. This extra information associated with the
path is called Path Overhead.
It allows the checking of aspect such as,
Quality of the overall end to end transmission.
Existence of path between two termination points.
Section Overhead
A section can be considered as one stage of an end path. It is defined as node to node
transmission. A path may be a number of sections .One section may be a path. The SDH also
reserves some extra capacity within the defined bit rates to carry information relating to the
section. This extra information associated with a section is called Section Overhead.
It contains data to control node-to-node transmission.
Protection switching
Error monitoring
Network management

21


Fig 2.7 Logical mapping of signals

How Is The Frame Composed ?
PDH Payload = Container (C)

Container + Path Overhead (POH) = Virtual Container (VC)

Virtual Container + TU Pointer = Tributary Unit (TU)

more than 1 Tributary Unit = Tributary Unit Group (TUG)

biggest Tributary Unit Group = Administrative Unit (AU)
Tributary Unit Group + AU Pointer = Administrative Unit (AU)

more than 1 Administrative Unit = Administrative Unit Group

Administrative Unit Group +
Section Overhead (SOH) = SDH Frame


TABLE 2.2
SDH denominations
PDH Standard SDH SDH Transport Corresponding
22





(Bit rates) Denomination Capacity SDH Bit rate
64 kbps VC-0 -
1.5 mbps VC-1 -
2 mbps VC-1 -
6 mbps VC-2 -
34/45 mbps VC-3 -
140 mbps VC-4 STM-1 155 mbps
VC-4x4 STM-4 620 mbps
VC-4x16 STM-16 2500 mbps
VC-4x64 STM-64 10 gbps
23


Figure 2.8 SDH Hierarchy - TUG Structure

2.4 BENEFITS OF SDH TRANSMISSION

High transmission rates
Transmission rates of up to 10 Gbit/s can be achieved in modern SDH systems. SDH is
therefore the most suitable technology for backbones.
Simplified add & drop function
Compared with the older PDH system, it is much easier to extract and insert low-bit rate
channels from or into the high-speed bit streams in SDH. It is no longer necessary to de-
multiplex and then re-multiplex the plesiochronous structure, a complex and costly
procedure at the best of times.
High availability and capacity matching
With SDH, network providers can react quickly and easily to the requirements of their
customers. For example, leased lines can be switched in a matter of minutes. The network
provider can use standardized network elements that can be controlled and monitored
24

from a central location by means of a telecommunications network management (TNM)
system.

Reliability
Modern SDH networks include various automatic back-up and repair mechanisms to
cope with system faults. Failure of a link or a network element does not lead to failure of
the entire network which could be a financial disaster for the network provider. These
back-up circuits are also monitored by a management system.
Future-proof platform for new services
Right now, SDH is the ideal platform for services ranging from POTS, ISDN and mobile
radio through, to data communications (LAN, WAN, etc.), and it is able to handle the
very latest services, such as video on demand and digital video broadcasting via ATM
that are gradually becoming established.
Interconnection
SDH makes it much easier to set up gateways between different network providers and to
SONET systems. The SDH interfaces are globally standardized, making it possible to
combine network elements from different manufacturers into a network. The result is a
reduction in equipment costs as compared with PDH.












25

CHAPTER 3
NETWORK MANAGEMENT

3.1 NETWORK TOPOLOGIES
Basic topologies possible in SDH are shown in figure below.


Figure 3.1 Possible topology in SDH architecture
Point-to-point:
The simplest topology is a permanent link between two endpoints. Switched point-to-point
topologies are the basic model of conventional telephony. The value of a permanent point-to-
point network is the value of guaranteed, or nearly so, communication between the two
endpoints. This topology doesnt provide redundancy. If the path is broken then the
communication will be over.

Ring:
The type of network topology in which each of the nodes of the network is connected to two
other nodes in the network and with the first and last nodes being connected to each other,
forming a ring all data that is transmitted between nodes in the network travels from one
node to the next node in a circular manner and the data generally flows in a single direction
only. But if any fault occurs in the transmission, then data will flow through the reverse
direction and provide redundancy.
26

Dual-ring
The type of network topology in which each of the nodes of the network is connected to two
other nodes in the network, with two connections to each of these nodes, and with the first
and last nodes being connected to each other with two connections, forming a double ring
the data flows in opposite directions around the two rings, although, generally, only one of
the rings carries data during normal operation, and the two rings are independent unless there
is a failure or break in one of the rings, at which time the two rings are joined (by the stations
on either side of the fault) to enable the flow of data to continue using a segment of the
second ring to bypass the fault in the primary ring.

Mesh
In this topology each node is connected to every node in the network. This topology gives
redundancy path but the network becomes very complex as the no. of nodes increases.

3.2 OPTICAL ADD DROP MULTIPLEXER
The main function of optical multiplexers is to couple two or more wavelengths into the
same fiber. It is clear that if a de-multiplexer is placed and properly aligned back to back with
a multiplexer, one could remove an individual wavelength and also insert an individual
wavelength. Such a function is called an optical add-drop multiplexer (OADM.).
The OADM selectively removes (drops) a wavelength from a multiplicity of wavelength in
the fiber, and thus traffic on this channel. It then adds in the same direction of dataflow the
same wavelengths, but with different data content.







Fig 3.2 OADM

27

OADMs are classified as fixed wavelength and as dynamically wavelength selectable
OADMs. In a fixed wavelength OADM, the wavelength has been selected and remains the
same until human intervention changes it. In dynamically selectable wavelength OADM, the
wavelengths between the optical de-multiplexer/multiplexer may be dynamically directed
from the outputs of the de-multiplexer to any of the inputs of the multiplexer.

3.3 COMPONENTS OF A SYNCHRONOUS NETWORK

Figure 3.3 Components of Synchronous network

Figure shows a schematic diagram of a SDH ring structure with various tributaries. The
mixture of different applications is typical of the data transported by SDH. Synchronous
networks must be able to transmit plesionchronous signals and at the same time, be capable
of handling future services such as ATM.
Current SDH networks are basically made up from four different types of network element.
3.3.1 Regenerators




Fig 3.4 Regenerators
28

Regenerator regenerates the clock and amplitude relationships of the incoming data signals
that have been attenuated and distorted by dispersion. They derive their clock signals from
the incoming data stream. Messages are received by extracting various 64 Kbit/s channels
(e.g. service channels E1) in the RSOH (regenerator section overhead). Messages can also be
outputed using these channels.

3.3.2 Terminal Multiplexers
Terminal multiplexers are used to combine plesionchronous and synchronous input signals
into higher bit rate STM-N signals.


Fig 3.5 Terminal multiplexers

3.3.3 Add/Drop Multiplexers (ADM)
Plesionchronous and lower bit rate synchronous signals can be extracted from or inserted into
high speed SDH bit streams by means of ADMs. This feature makes it possible to set up ring
structures, which have the advantage that automatic back-up path switching is possible using
elements in the ring in the event of a fault.


Fig 3.6 ADM



29

3.3.4 Digital Cross Connects (DXC)
This network element has the widest range of functions. It allows mapping of PDH tributary
signals into virtual containers as well as switching of various containers up to and including
VC-4.

Fig 3.7 DXC
The telecommunications management network (TMN) is considered as a further element in
the synchronous network. All the SDH network elements mentioned so far are software-
controlled. This means that they can be monitored and remotely controlled, one of the most
important features of SDH.

3.4 PROTECTION IN RING ARCHITECTURE
Two basic types of protection architecture are distinguished in APS (Automatic Protection
Switching). One is the linear protection mechanism used for point-to-point connections. The
other basic form is the so-called ring protection mechanism which can take on many
different forms. Both mechanisms use spare circuits or components to provide the back-up
path. Switching is controlled by the overhead bytes K1 and K2.

3.4.1 Linear Protection
The simplest form of back-up is the so-called 1 + 1 APS. Here, each working line is
protected by one protection line. If a defect occurs, the protection agents in the network
elements at both ends switch the circuit over to the protection line. The switchover is
triggered by a defect such as LOS. Switching at the far end is initiated by the return of an
acknowledgment in the backward channel. 1+1 architecture includes 100% redundancy, as
there is a spare line for each working line.
Economic considerations have led to the preferential use of 1: N architecture, particularly for
long-distance paths. In this case, several working lines are protected by a single back-up line.
30

If switching is necessary, the two ends of the affected path are switched over to the back-up
line.
The 1+1 and 1: N protection mechanisms are standardized in ITU-T Recommendation G.783.
The reserve circuits can be used for lower-priority traffic, which is simply interrupted if the
circuit is needed to replace a failed working line.

Fig 3.8 1:3 Linear Protection

3.4.2 Ring Protection
The greater the communication bandwidth carried by optical fibers, the greater the cost
advantages of ring structures as compared with linear structures. A ring is the simplest and
most cost-effective way of linking a number of network elements. Various protection
mechanisms are available for this type of network architecture, only some of which have
been standardized in ITU-T Recommendation G.841. A basic distinction must be made
between ring structures with unidirectional and bi-directional connections.

Unidirectional rings
Figure shows the basic principle of APS for unidirectional rings. Let us assume that there is
an interruption in the circuit between the network elements A and B. Direction y is unaffected
by this fault. An alternative path must, however, be found for direction x. The connection is
therefore switched to the alternative path in network elements A and B.
31

The other network elements (C and D) switch through the back-up path. This switching
process is referred to as line switched. A simpler method is to use the so-called path
switched ring. Traffic is transmitted simultaneously over both the working line and the
protection line. If there is an interruption, the receiver (in this case A) switches to the
protection line and immediately takes up the connection.

Fig 3.9 Two fiber unidirectional path switched ring

Bi-directional rings







Fig 3.10 Two fiber bi-directional line switched ring

In this network structure, connections between network elements are bi-directional. This is
indicated in the figure by the absence of arrows when compared with above figure. The
overall capacity of the network can be split up for several paths each with one bi-directional
working line, while for unidirectional rings, an entire virtual ring is required for each path. If
a fault occurs between neighboring elements A and B, network element B triggers protection
switching and controls network element A by means of the K1 and K2 bytes in the SOH.
32

Even greater protection is provided by bi-directional rings with 4 fibers. Each pair of fibers
transports working and protection channels. This results in 1:1 protection, i.e. 100 %
redundancy. This improved protection is coupled with relatively high cost.

Retentive and Non Retentive Switch

Retentive Switch: Automatically takes its original path after recovery of the path in case of
breakup.
Non Retentive Switch: In case of break up alternate path will work and it will continue to
work in spite of original path is now ready to work.




















33

CHAPTER 4
STRUCTURE OF BTS

4.1 BTS (BASE TRANSCEIVER STATION)
The Base Transceiver (BTS) belongs to the radio part of a base station system. Controlled by
BSC, it serves the radio transceiving equipment of a certain cell, implements the conversion
between BSC and radio channels, radio transmission through air interface between BTS and
MS and related control, and communicates with BSC through the Abis interface.
4.1.1 Overview of the HUAWEI BTS3900
A cellular Base Transceiver Subsystem (BTS) is one part of a cellular infrastructure system.
The Basic functions of cellular infrastructure equipment are to provide the fixed end of the
Radio interface to subscribe cellular phones and to route voice and data traffic up to the
Public Switched Telephone Network (PSTN). The BTS3900 is an indoor macro base station
developed by Huawei. The BTS3900 mainly consists of the BBU3900 and the RFUs.
Compared with traditional BTSs, the BTS3900 features simpler structure and higher
integration.
The BTS3900 has the following features:
1. It is developed on the basis of the unified BTS platform for Huawei wireless products
and enables the smooth evolution from 2G to 3G.
2. It supports the Abis IP/FE interface in hardware and enables Abis over IP through
software upgrade if required.
3. It shares the BBU3900 sub rack, which is the central processing unit, with the
DBS3900 to minimize the number of spare parts and reduces the cost.
4. It can be flexibly installed in a small footprint and can be easily maintained with low
cost.
5. It supports 2-way and 4-way RX diversity (not supported by the GRFU) to improve
the uplink coverage.
6. It supports the GPRS and the EGPRS.
7. It supports Omni directional cells and directional cells.
8. It supports multiple topologies, such as star, tree, chain, ring, and hybrid topologies.
9. It supports the cell broadcast SMS and point-to-point SMS.
34

4.1.2 Structure of the BTS Cabinet
The BTS3900 cabinet adopts the module structure. It consists of the BBU3900, CRFU, FAN,
DCDU-01, and SLPU (optional). A space is reserved at the bottom of the cabinet for the
installation of user devices such as the transmission equipment.


Figure 4.1 Internal structure of the BTS3900 cabinet

4.1.3 Configuration of the BTS Cabinet
The BTS3900 cabinet supports the typical configuration with three CRFUs and the full
configuration with six CRFUs. The SLPU is an optional component of the BTS3900 cabinet.
Typical configuration of BTS 3900 is as shown in figure 4.2 below. Different cards for BTS
are as shown below used in BTS configuration.
35


Figure 4.2 Typical configuration of the BTS3900 cabinet

TABLE 4.1
Describes the functions of the main components of the BTS3900 cabinet.

Component Description

CRFU CRFU is the CDMA RF unit of the BTS3900. It receives and sends
radio signals for communication between network system and MS.
FAN The FAN is the fan unit of the BTS3900. It houses fans for heat
dissipation in the BTS3900 cabinet.
BBU3900 The BBU3900 is the baseband unit of the BTS3900. It performs
resource management, operation maintenance, and environment
monitoring for the BTS.
DCDU-01 The DCDU-01 is the direct current distribution unit of the BTS3900.
It supports one DC input and multiple DC outputs.
SLPU
(optional)

It is the protection unit of the BTS3900 cabinet, and it houses the
UELP and UFLP board for protecting the E1/T1 and FE signals from
lightning

36



4.1.4 Logical Structure of the BTS
This describes the logical structure of the BTS. Logically, the BTS consists of the baseband
system, RF system, power system, and antenna system.


Figure 4.3 Logical structure of the BTS3900

4.1.5 Baseband System
The baseband system consists mainly of BBU3900s and performs the following functions:
1. Providing the physical interface for data exchange between the BTS and the BSC.
2. Modulating and demodulating baseband data and CDMA channel signals.
3. Providing system synchronization clock signals.
4. Implementing resource management, operation and maintenance, and environment
monitoring.

4.1.6 RF System
The RF system consists mainly of CRFUs and performs the following functions:
1. On the forward link, implementing up-conversion and power amplification for
modulated transmitted signals and filtering the transmitted signals to make them meet
the requirements of the Um interface protocol.
2. On the reverse link, filtering the signals received by the antenna to suppress out-band
interference and performing low noise amplification, channel division, down-
conversion, and channel-selective filtering.
37

4.1.7 Power Supply System
The power supply system consists mainly of DCDUs and performs the following functions:
1. The DCDU is a DC power distribution unit and provides -48 V DC power input for
the components in the cabinet.
4.1.8 Antenna System
The antenna system consists of the RF antenna system and satellite antenna system. The
antenna system performs the following functions:
Satellite antenna system
Through the satellite synchronization antenna, the BTS receives signals from the GPS or
GLONASS system and performs wireless synchronization.
RF antenna system
The RF antenna system transmits modulated RF signals and receives the signals from the
MS.
4.1.9 Clock Synchronization Modes of BTS
The BTS supports various clock sources, such as the GPS clock source, interface clock
source, Abis interface clock source, and internal clock source.
TABLE 4.2
Clock synchronization modes supported by the BTS
Clock
Synchronization
Type
Description
GPS clock source The BTS provides the GPS clock input port and obtains
clock signals through the external GPS equipment.
Abis interface clock
Source
The BBU3900 supports the extraction of clock signals
directly from ports such as the E1/T1 port. The clock module
performs frequency division, phase locking, and phase
adjustment for the clock signals. In this way, precise 2 MHz
and 8 KHz clock signals are obtained and used for frame
synchronization and bit synchronization inside the BTS.
Internal clock signals When external clock sources are not available, the crystal
oscillators of the BBU3900 boards provides 10 MHz clock
signals to guarantee the normal running of the BTS.
38

4.1.10 Performance Specification of the BTS
This describes the performance specifications of the BTS in terms of transmitter and receiver
specifications, CRFU cascading specifications, and BERs on transmission links.
Transmitter and Receiver Specifications:
The transmitter and receiver specifications refer to the technical parameters of the transceiver
of the BTS. The receiver and transmitter specifications of the BTS in different band classes
are as follows:

TABLE 4.3
Transmitter specifications (800 MHz)
Item Specification
Working frequency band 869 MHz to 889 MHz
Channel bandwidth 1.2288 MHz
Channel precision 30 kHz
Frequency tolerance 0.05 ppm
Transmit power 80 W


TABLE4.4
Receiver specifications (800 MHz)

Item Specification
Working frequency band 824 MHz to 844 MHz
Channel bandwidth Channel bandwidth
Channel precision 30 kHz
Signal receiving sensitivity Better than -130 dBm (main and diversity
receiving at RC3)







39

CHAPTER 5
DIFFERENT TYPES OF MULTIPLEXERS


5.1 CLASS OF MUXS USED BY TTSL

Micro SDM
BG 20B/E/C
XDM 100
XDM 300
XDM 500
XDM 1000
Common Functionality

Most cross-connect, timing, and control functionality is integrated and internal to the
main card in BG-20, the MXC20. No separate card is used to control these operational
aspects of the unit. Besides this common functionality, the MXC20 also supports
various traffic interfaces, such as STM-1/4 aggregates, E1, and FE interfaces.

MXC20 functionality includes:

Integrated cross connection, timing, system control, and overhead processing
(including DCC and Clear Channel)

Communication with and control of a daughterboard in the Dslot and extension cards in
the BG-20E shelf through the backplane

Control-related functions

Communications and control (by the CPU)

Alarms and maintenance

Fan control

SDH-related functions

SDH timing and synchronization


40


5.2 SDM-1E


Figure 5.1 MicroSDM MUX

These are third generation Broad gate multiplexers, optimally designed for installation in
street cabinets and customer premises locations. This type of equipment enables the
implementation of small and simple Access network topologies that are fully managed,
flexible, and very cost-effective. With Lights cape Networks new SDM-1E multiplexers,
telecom operators can achieve a high level of service and increased revenues, as they benefit
from the following advantages:
1. Low cost per line
2. Advanced fiber and copper technologies
3. Integrated management system
4. Support of a wide range of services.
5. Flexible configuration and easy upgradability.
The maximum capacity of this mux is 63 E1 and it does not provide Ethernet interface.
MAC CARD
The MAC card houses one or two O/E modules which are piggyback mounted mini-boards.
The O/E modules provide the SDH line interfaces (optical or electrical). An additional card
41

mounted on the MAC is the Timing Module Unit (TMU).
The CDB Card
The CDB provides control and processing functions to the MAC card and the TEX card
(when fitted). It houses the power supply as well as various memory modules (including the
NVM, which is mounted on the CDB). The central processing unit is a state-of-the-art
PowerPC RISC processor.
The TEX Card
The TEX card is an optional expansion card fitted into the SDM-1E which provides tributaries
interfaces expansion as follows TEX 2_42 support Up to 42 E1.

5.3 BG-20B (BROADGATE-20)

Figure 5.2 BG-20B

ECI Telecoms BG-20 miniature MSPP delivers a cost-effective and affordable mix of
Ethernet, SDH, PDH, and PCM services, resulting in new revenue-generating opportunities.
It offers a wide variety of features and benefits, including:
1. Ultra-high scalability based on coupling the BG-20E to the BG-20B to make a
build-as-you-grow solution.
2. Gradual capacity expansion based on service provisioning needs. More STM-1
interfaces can be added very conveniently and ADM-1s can be upgraded to
ADM-4s without affecting traffic. This highly adaptable and flexible architecture
translates into significant savings in both operational and capital expenditures
(OPEX and CAPEX).
42

3. Provides a carrier class Ethernet-over-WAN/MAN solution (including Ethernet
over SDH and Ethernet over PDH) with SDH reliability, security, and
management of data services.
4. PCM service interfaces and 1/0 digital cross-connect functions to facilitate the
construction and maintenance of various private networks.
5. Multi-ADM and cross-connect functionality, ideal for deployment in flexible
network topologies like ring, mesh, and star.
6. Compactness and resiliency, perfectly suited for both indoor and outdoor
enclosures. Due to its extended operating temperature range, it is also most
suitable for harsh environmental conditions.
7. The maximum capacity of BG-20 is STM-4. When the capacity increase beyond
the STM-4 than we directly use the XDM-100
MXC20 Card
The MXC20 supports the following interfaces: 21xE1, 6 Ethernet port, 2 ports forSTM-1/4,
MNG for local login, RS-232, housekeeping alarms. In addition to these interfaces, the
MXC20 has LED indicators and one push button. It also consist one D-slot for providing
more interface. As the BG-20 is a front-access shelf, all its interfaces, LEDs, and push button
are located on the front panel of the MXC20. Now we discuss about the cards that are
inserted into the D-slot.
ME1_21H card
ME1_21H is a D-slot module with 21 x E1 (2.048 Mbps) balanced electrical interfaces. The
cabling of the ME1_21H module is directly from the front panel with a twin 68-pin VHDCI
female connector.
ME1_42H Module
The ME1_42 is a D-slot module with 42 x E1 (2.048 Mbps) balanced electrical interfaces.
The cabling of the ME1_42 module is directly from the front panel with two twin 68-pin
VHDCI female connectors.
SMD1H Module
43

The SMD1H is an SDH D-slot module with two STM-1 (155 Mbps) interfaces (either optical
or electrical).
OMS4H Module
The OMS4H is an SDH D-slot module with one STM-4 (622 Mbps) optical interface.
MEoP_4 Module
The MEoP is an L1 data Dslot module with four 10/100BaseT interfaces on the LAN side
and four EoP interfaces on the WAN side. The total WAN bandwidth is 32xE1.

5.4 BG-20E (BROADGATE-20)
BG-20E is same as the BG-20B but the only difference is that we expand the cards in the
BG-20E. Remaining all the things are same in both cases. Three extension slots are available
in the BG-20E to accommodate the various types of extension cards. These cards are:
PE1_63 Card
The PE1_63 is an electrical traffic card with 63 x E1 (2 Mbps) balanced electrical interfaces.
A maximum of three PE1_63 cards can be installed in one BG-20E shelf. The cabling of the
PE1_63 card is directly from the front panel with three twin 68-pin VHDCI female
connectors.
S1_4 Card
The S1_4 card is an SDH extension card with four STM-1 (155 Mbps) interfaces (either
optical or electrical).
ESW_2G_8F_E Card
The ESW_2G_8F_E is an EoS Metro Ethernet L2 switching card with 8 x 10/100BaseT
LAN interfaces, 2 x GbE LAN interfaces, and 16 EoS WAN interfaces. The total WAN
bandwidth is up to 4 x VC-4. A maximum of three ESW_2G_8F_E cards can be installed in
one BG-20E shelf.

5.5 BG-20C (BROADGATE-20)
It is same as the BG-20B but the only difference is that it does not have the D-slot and it
contains only four Ethernet port.





44

5.6 XDM-100

Figure 5.3 XDM-100

ECI Telecom's XDM-100 miniature MSPP delivers a cost-effective and affordable mix of
Ethernet, SDH and PDH services, resulting in new revenue-generating opportunities. It offers
a wide variety of features and benefits, including:
1. Gradual in-service capacity expansion based on service provisioning needs. An
optical connection operating at a specific STM rate can be upgraded from STM-1
to STM-4/16 without affecting traffic. This high adaptability and "build-as-you-
grow architecture means significant savings in both OPEX and CAPEX.
2. Multi-ADM and cross-connect functionality makes XDM-100 ideal for
deployment in flexible network topologies, such as ring, mesh and star.
3. The XDM-100 is compact and resilient, making it perfectly suited for both indoor
and outdoor enclosures, as well as for harsh environmental conditions, due to its
extended operating temperature range.
All electrical connections are located directly in the tributary modules; therefore, the XDM-
100 does not need additional electrical interface connections.
To support system redundancy, each MXC card contains an integrated xINF (XDM Input
Filter) unit with connectors for two input power sources.
The xFCU-100 fan control unit at the right side of the shelf provides cooling air to the
system. It contains nine separate fans for added system redundancy. Air is drawn in by the
fans from the right side of the chassis and exhausted through the horizontally mounted cards
and modules and through the left side of the chassis. Redundant controllers, located on the
two MXC cards, activate the fans. The xFCU-100 can be extracted and replaced without
45

interrupting the multiplexer operation, provided the replacement does not exceed a few
minutes.
The basic XDM-100 cage contains slots for I/O interface modules, and dedicated slots for the
MXC cards and the ECU. The cages design and mechanical practice conform to
international mechanical standards and specifications. The modules and cards are distributed
as follows:
1. Eight (8) slots, I1 to I8, optimally allocated for I/O interface modules.
2. Two (2) slots, A and B respectively, allocated for the MXC cards (main and
protection). Each MXC card has two slots (A1 and A2 and B1 and B2) to
accommodate SDH aggregate modules.
3. One (1) slot allocated for the ECU card.
The ECU is located beneath the MXC cards. Its front panel features several interface
connectors for management, external timing, alarms, order wire and overhead (future
release). It also includes alarm severity colored LED indicators and selectors plus a display
for selecting specific modules and ports for monitoring purposes.
MXC(MAIN CROSS-CONNECT AND CONTROL) CARD
The basic and expanded versions of the XDM-100 shelf accommodate two identical
MXC cards. By default, the MXC-A is the main card and MXC-B is the protection card.
Both cards perform the following functions simultaneously in a 1+1 protection
configuration:
1. Communications and control
2. Alarm and maintenance
3. Cross-connect
4. Timing and synchronization
5. Distribution of power supply to all modules (xINF function)
6. Routing and handling of 32 DCC channels
In addition, the MXC accommodates the NVM compact flash memory card and houses SDH
aggregate modules (SAM). The additional MXC card provides 1+1 protection to the cross
connect matrix and full 1:1 protection to all other functions, since the standby MXC has an
identical database to the active MXC.
46

In case of a hardware failure in the active MXC or its traffic interconnection, the I/O
interface modules switch to the protection MXC within 50 ms. Similarly, in case of a
hardware failure in the Timing Unit (TMU) of the operational MXC card, the backup TMU
takes over the timing control with no disruption in traffic.
ECU(EXTERNAL CONNECTION UNIT) CARD
The ECU connects management, alarms, overhead access, and order wire interfaces to the
active MXC card. This card also provides the physical connections for these interfaces. Two
types of ECU cards are available for the XDM-100: ECU-F and ECU (reduced cost). The
ECU-F supports the following management and alarm interfaces and functions:
1. Ethernet interface to XDM element management system
2. Ethernet hub for multiple NE connections
3. USB interface (future option)
4. Synchronization inputs and outputs
5. Alarm severity outputs (Critical, Major, Minor, Warning)
6. External alarm outputs and inputs
7. Operation and alarms LEDs
8. Selection and display of traffic interfaces for monitoring purposes
9. Multiplexer reset.
AGGREGATE MODULES
Two SDH aggregate modules (SAM) plug into each MXC. The MXC provides the aggregate
modules with power and control. The traffic buses of each SAM are connected to both MXC
cards. A variety of aggregate modules with electrical, optical and mixed interfaces, and at bit
rates from STM-1 to STM-16 are available.
I/O MODULES
Eight slots are available in the XDM-100 shelf to accommodate the various types of I/O
modules. Each type of module (PIM, SIM or EIS-M) can be inserted in any of the I1 through
I8 positions without limitation (the EIS-M module occupies two slots). PIM and SIM
modules, with electrical interfaces, fully supports direct connection to the module without
other external connection modules.



47

TABLE 5.1
List of the XDM-100 I/O modules

















48

CHAPTER 6
ANTENNAS
6.1 PATCH ANTENNA

Figure 6.1 Patch Antenna

GMS offers variety of Patch (Panel) antennas in bands from 1.7-6 GHz. They are light-
weight and housed in a weather-proof housing. The Messenger Antenna Patch (MAP) is
a precision, high gain antenna designed for broadband receivers and transmitters where wide
bandwidth and high efficiency are key system parameters. They are designed to either output
RF directly, or can be configured to include an internally-mounted GMS LNA or Block-
Down Converter. GMS also supplies this Antenna in a 360 degree array configuration called
Messenger Antenna Array (MAA) for tracking applications with the Messenger Smart
Receiver (MSR).

6.2 OMNI DIRECTIONAL ANTENNA
GMS offers variety of Omni antennas in bands from 1.7-16 GHz. They are light-weight and
housed in a strong weather-proof PVC housing.

49


Figure 6.2 Omni Directional Antenna

6.3 HELICAL ANTENNA


Figure 6.3 Helical Antenna

GMS Helical (Rod) antennas Right Hand Circular Polarization (RHCP) and range in gain
from 6, 12 and 16 dBic. They are lightweight and constructed from strong, gel-coated
fiberglass and have an aluminum mounting plate.

6.4 DISK ANTENNA
GMS offers high accuracy parabolic spun aluminum dishes that are designed with rugged
portability in mind. The dish sizes are 24 or 30 inches in diameter and come with tripod or
pole-mount hardware. A wide selection of Linear or Circular feeds that cover 1.7-16 GHz
with quick-release option are also available.
50



Figure 6.4 Disk Antenna

6.5 YAGI ANTENNA

Figure 6.5 Yagi Antenna

GMS offers variety of Yagi antennas in bands from 1.7-5 GHz with typical gain of 10 or 14
dBic. They are light-weight and housed in a weather-proof radome.




51

CHAPTER 7
DIFFERENT CONNECTERS AND CORDS

7.1 PATCH CORDS
A patch cable or patch cord is an electrical or optical cable used to connect ("patch-in") one
electronic or optical device to another for signal routing. Devices of different types (e.g., a
switch connected to a computer, or a switch to a router) are connected with patch cords.
Patch cords are usually produced in many different colors so as to be easily distinguishable.
Types of patch cords include microphone cables, headphone extension cables, XLR
connector, Tiny Telephone (TT) connector, RCA connector and " TRS connector cables (as
well as modular Ethernet cables), and thicker, hose-like cords (snake cable) used to
carry video or amplified signals. However, patch cords typically refer only to short cords
used with patch panels.
Patch cords can be as short as 3 inches (ca. 8 cm), to connect stacked components or route
signals through a patch bay, or as long as twenty feet (ca. 6 m) or more in length for snake
cables. As length increases, the cables are usually thicker and/or made with more shielding,
to prevent signal loss (attenuation) and the introduction of unwanted radio frequencies and
hum (electromagnetic interference).
Patch cords are often made of coaxial cables, with the signal carried through a shielded core,
and the electrical ground or earthed return connection carried through a wire mesh
surrounding the core. Each end of the cable is attached to a connector so that the cord may be
plugged in. Connector types may vary widely, particularly with adapting cables.
Various Patch Cords are:
LC
SC
FC
E2000
ST
52




Figure 7.1 Various Patch Cords

7.2 CONNECTORS
An electrical connector is an electro-mechanical device for joining electrical circuits as
an interface using a mechanical assembly. The connection may be temporary, as for portable
equipment, require a tool for assembly and removal, or serve as a permanent electrical joint
between two wires or devices.
There are hundreds of types of electrical connectors. Connectors may join two lengths of
flexible copper wire or cable, or connect a wire or cable or optical interface to an
electrical terminal.
In computing, an electrical connector can also be known as a physical
interface (compare Physical Layer in OSI model of networking). Cable glands, known
as cable connectors in the U.S., connect wires to devices mechanically rather than
electrically and are distinct from quick-disconnects performing the latter.


53




Figure 7.2 Different types of Connectors



















54

CHAPTER 8
WIRELESS LINKS

8.1 MICROWAVE LINK
8.1.1 Overview of Microwave Link
Microwaves in a descriptive term, is used to identify electromagnetic waves in the frequency
spectrum ranging from 1 GHz to 30 GHz (telecom). Microwaves frequency characteristics
are very similar to light, depending upon propagation in different ways causing attenuation to
the original wave. Microwave communication systems require high frequency signals for
effective transmission of information. There are several factors that lead to this requirement.
For example, an antenna radiates effectively if its size is comparable to the signal
wavelength, since the signal frequency is inversely related to its wavelength, antennas
operating at higher radiation efficiencies. Further their size is relatively small and hence
convenient for mobile communication. Another factor that favours RF and microwaves is
that the transmission of broadband information requires high frequency signal.
The ionosphere does not reflect microwaves and the signals propagate at line of sight. Hence,
curvature of earth limits the range of microwave communication link to less than 50 km. One
way of increasing the range of microwave link is to place the repeater intervals. This is
known as terrestrial communication.
As TTSL communication is using two Types of technology for transportation of data and
voice traffic. It is not possible to make OFC network everywhere at city areas because fiber is
very costly. Two types of network technology is responsible for making connectivity between
one BTS (base transceiver station) to its next BTS. Such a ring connectivity network reaches
to MSC (mobile switching centre). Microwave antennas 0.6m to 0.8m are generally used to
make point to point connection between two BTS.
55


Figure 8.1 Real time Microwave connectivity

When there is a customer group available in some area out of the radiation coverage then all
the times it will not be economical to install another BTS with fiber ring connectivity and use
all transport equipment again. In such cases we can install nearby BTS with Microwave
connectivity. This will be point to point link provided by drum antennas. It will use
appropriate ODU and IDU for conversion from RF signals to E1 lines. Then using this E1s,
again we can serve customers as mentioned above.
8.1.2 Frequency Allocation
6 and 7 GHz frequency bands are used for intercity backbone routes. Nominal hop
distances are 5-50 Kms.
15, 18 and 23 GHz frequency bands are used for access network. Hop distances are 1-
10 Kms.
Frequency spots in 6 and 7 GHz are extremely crowded. Hence frequency allocation
in this band is subjective from place to place. The Tx/Rx separation is fixed at 152
and 154 MHz.
The frequency spectrum in 15 GHz is from 14.25 to 15.35 GHz. The frequencies are
further classified into various sub bands with channel numbers.
In long run OFC would be the right choice, as it will attract no recurring license cost.
56

8.1.3 Pasolink System Features
Single chip modulator/ demodulator (fully digital)
High reliability
Low power consumption
Allows smaller antenna and reduced system cost
With PASOLINK PDH (QPSK) and PASOLINK PLUS SDH (32 QAM)
Forward error correction (FEC)
Transmit power controlled in two ways: Automatic transmit power control(ATPC)
and Manual transmit power control(MTPC)
Common IDU for different RF frequencies.
Remote monitoring of ODU operation.
Local and remote supervision function on IDU.
Local monitor and maintenance using Local Craft Terminal (LCT).
8.1.4 IDU (Indoor Unit)


IDU is an Indoor Unit placed inside the shelter and connected to ODU (Outdoor Unit) with
help of IF cable, with maximum distance of approx. 300 mts. IDU is connected to electric
cable called E1.


IDU
alarms
ODU
alarms
Power
alarms
maintenance
alarms
Reset switch
Router
connection
Optional
Ethernet
connection
optional
Engineering order
wire connection (
EOW)
Buzzer
Waysid
e
optional
IF connection
to ODU
Earthing Point
Red LED
Indicates Alarm
Figure 8.2 IDU
57

PRINCIPLE
Principle of IDU is to convert IF signal into optical or electrical signal. There are two types
of IDU:
1. SDH pasolink IDU
2. PDH pasolink IDU
In SDH IDU, we do not get directly electric E1 but first the optical output of IDU is given to
MUX which converts optical output to electric and from Mux we get electrical output from
DDF (Digital Distribution Frame), then the output is given to customer. So, SDH gives
optical output which is converted to electric with help of DDF. In PDH we directly get the
electric output and there is no need to use DDF. But the capacity of PDH IDU is less then
SDH IDU. It supports up to 16 E1 only, whereas SDH IDU can support upto STM-1
capacity.

8.1.5 ODU (Outdoor Unit)
PRINCIPLE
Principle of ODU is to convert IF (Intermediate Frequency) into RF and vice versa. Its design
depends on requirement. Microwave frequency ranges from 6 GHz to 18 GHz.

Figure 8.3 Outdoor Unit
The actual TX frequency of the ODU should be within the TX radio frequency band of the
ODU and is entered using the local craft terminal (LCT). The corresponding RX frequency is
automatically set after the TX frequency is entered. For 6/7/8 GHz band ODU, the frequency
setting should be the same as that written on the ODU label.
PASOLINK provides point-to-point wireless solution that fit in a variety of network
applications. All the PASOLINK systems feature simple installation and fast rollout, reliable
operation, and offer high-speed transmission, scalable future.
58

8.1.6 Antenna (ODU) Alignment
During alignment of the antenna always refer NDD for alignment planning and
antenna angles. (Latitude, Longitude, Azimuth, Elevation, Height of antenna etc.)
Make a short check of adjustability and free rotation in all directions.
For the azimuth adjustment of short (urban) distance links, use of a geographic map is
most efficient.
Use compass for coarse direction finding.
If the opposite antenna is not visible, define a remarkable / noticeable object (e.g.
building, tree, street-crossing, etc) which is in line with the opposite site and can be
found with the above mentioned tools (maps, compass).
Install the antenna at proper height for LOS clear visible.
Proper route IF cable and check the cable connector connection is proper.
Install IDU in Rack and give -48v dc input voltage
Connect DDF with IDU if PDH site or with MUX if SDH site.

8.1.7 System Configuration
System protection is required to ensure robustness and survivability of the data link in the
case of any radio links problem:
Equipment problems (hardware / software failure)
Propagation problems (fading / obstruction)
The protected configuration would assure the link is up in case of hardware failure and allow
maintenance and repair of the redundant (standby) units.





59

8.1.8 Non Protected System

Figure 8.4 Non-Protected System
One IDU with modulation / demodulation channel
One ODU
One antenna
The system has no protection channel (no switching over)
8.1.9 Protected System: Single Antenna Configuration

Figure 8.5 Protection by two ODUs
One IDU with two modulation / demodulation module
Two ODU working at the same spot frequency
One antenna
On each side only one ODU sends TX power and both ODUs receive the RX power
Only one system is selected to carry the traffic and the other system is standby
TX & RX switching is available manually and automatically to control switch over
function
TX & RX switching over does not affect the traffic.
8.2 FREE BAND RADIO LINK
8.2.1 Introduction
FBR (Free band radio) can be used to provide services like, leased line, PRI etc. Bandwidth
up to 8 Mbps (two ways) can be provided using FBR. Varieties of customer services can be
60

provided using FBR. It can also be used for DLC. FBR are actually useful at the place where
fiber cannot be deployed and hence communication is required to be done through air
interface.

Figure 8.6 Structure of FBR
The free band radio delivers up to 8 Mbps of total data rate for Ethernet and E1/T1 traffic.
The system supports a variety of spectrum bands and can be configured to operate in any
channel on the band with a carrier step resolution of 20 MHz.
The unlicensed band radio employs Time Division Duplex (TDD) transmission. This
technology simplifies the installation and configuration procedure. There is no need to plan
and to allocate separate channels for the uplink and downlink data streams. Operation over
2.4GHz and 5.8GHz bands is not affected by harsh weather conditions, such as fog, heavy
rain etc.

8.2.2 Need of FBR
FBR is called free band because we dont have to pay for this band (2.4Ghz and 5.8Ghz). In
other words, if one wants, one can start service almost immediately using unlicensed band
radios and one need not wait for one year for frequency clearance. This presents great
opportunities for service providers.
61

Free Band Radio offers advantages such as
Immediate and hassle free deployment of services as no clearance from WPC are
required.
Radios are very cost effective.
Fast realization of revenue (as a result of rapid deployment)
Demand-based build-out.
Cost shifts from fixed to variable components (with traditional wire-line systems,
most of the capital investment is in the infrastructure, while with radio a greater
percentage of the investment is shifted to CPE, which means an operator spends
money only when a revenue-paying customer signs on)
No stranded capital when customers churn
Cost-effective network maintenance, management, and operating costs.
Limitations Of free band radio
Since radio operates in unlicensed band, protection from interference is not
guaranteed. Since it is intended to be deployed in very remote areas, where not much
interference is expected and also the parabolic antennas have very narrow beam,
which provides an additional protection against interference.
Lack of standards.
8.2.3 Physical Installation of the FBR
Installation of antennas.
Install ODU at both sites of the link.
Install ODU cable and connecting ODU to IDU at both sites.
Connect power.
Install the management program on the network management station.
Run the Installation wizard from the management program.
Alignment of the antennas.
Connect network and customer equipment to the local and remote IDUs respectively.
Proper grounding of all equipments.


62

8.2.4 IDU (Indoor Unit)
Indoor unit is installed in the customer premise. This is the unit, which interfaces with
customer equipment, which in most of the cases is a router. This unit receives modulated
digital signal over Cat5 cable from ODU. It then de-multiplexes payload, FEC, Management
data etc from the digital steam and reconstructs and retimes E1s or similar signals, which are
then send to customer equipment. IDU is independent of frequency and hence ODU. IDU can
work with any frequency band ODU like 2.4 GHz or 5.8 GHz.

Figure 8.7 IDU
Different types of IDUs and their applications,
2E1+FE IDU
This IDU provides 2E1 and One Fast Ethernet ports. This can be used where up to 2E1 ports
are required. In such cases, FE port at Hub can be used for monitoring.
2E1+2FE IDU
This IDU provides Two E1s and Two Fast Ethernet ports. This IDU will replace the old
2E1+FE for all the new cases. This can be used where up to 2E1+ One FE services are
required.
4E1+2FE IDU
This IDU provides Four E1s and Two Fast Ethernet solution. This can be used where up to
4E1+ One FE services are required. Note that more than 2 E1, in normal circumstances is not
recommended because of high S/I requirement.

8.2.5 ODU (Outdoor Unit)
This is radio frequency unit, which is mounted on a pole on the rooftop of the building or on
the tower. This unit receives radio signal, down converts and after demodulation recovers the
63

digital signal. The recovered digital signal is send to IDU over Cat5 cable. In the transmit
direction the similar reverse process is done by the ODU.
In TTSL network now two type of ODU are deployed:
1. 2.4GHz
2. 5.8GHz

Figure 8.8 ODU
8.2.6 Various Connections
CONNECTION BETWEEN THE ODU AND IDU
The ODU-IDU cable is Ultraviolet Proof CAT-5e, 4 twisted-pair 24 AWG FTP. It is
terminated with RJ-45 connectors on both ends. It is covered by a cable gland on the ODU
side for hermetic sealing. It conducts all the user traffic between the IDU and the ODU and
also provides -48 VDC supply to the ODU. The maximum length for one leg of the cable is
100m (328ft) in accordance with10/100BaseT standards.
The cable should be clamped directly on the surface with cable ties at 600mm interval. The
cable will be laid inside the building through PVC channel. Make sure that some spare length
is left for future maintenance purpose.
CONNECTION BETWEEN THE ODU AND ANTENNA
The external antenna is connected to the ODU using a co-axial RF cable. An N type RF
connector is provided on the ODU for this. Both ends of the RF cable are to be tightly sealed
with weather proofing tape.
DATA CABLE
ODU and IDU are connected by Cat5 cable. This cable carries not only the IF signal but also
DC Voltage to power ODU. It means that IDU is also used for POE ( Power over Ethernet).
Thus a separate power cable for ODU is not required.
8.2.7 How Interface can be Overcome?
KEEP THE LINK DISTANCE SMALL IN URBAN AREAS
64

Small link distance is possible in TSL network, as the numbers of CDMA BTS, which are the
take-off point for FBR, are large. Thus probability of finding a BTS in reasonable radius,
around potential customer site, is very high. C/I will not get affected adversely unless there is
very close source interference near the prospective UBR site.
EMPLOY HIGH GAIN ANTENNAS
High gain parabolic antennas provide dual protection. By virtue of high gain they increase
the signal quality and by small beam width they reject interfering signals.



















65

CHAPTER 9
REPEATER
9.1 INTRODUCTION
Repeaters are bi-directional amplifiers used with highly directional antennas to increase the
coverage area of a base station. Repeaters are not designed to increase the base station
capacity but will improve signal strength out past the normal operating area for both uplink
and downlink traffic.
Repeaters are normally located at the outer limit of the base station coverage area and
retransmit both the base station downlink signal to mobiles and the mobiles uplink signal
back to the base station. Repeaters can also be used to boost signal strength inside a building
where mobile users are operating in a highly attenuated area behind coated windows that
reflect RF energy or lossy cement and steel walls.
What is need of Repeater?
Cell enhancing solution with lower cost.
Many kinds of cell enhancing applications are available from small room to large
coverage.
Lower cost cell coverage extension solution than BTS.
Flexible cell coverage planning.
Easy maintenance of Repeater than BTS



Figure 9.1 shrinking area
Shrinking Area
In Shrinking Area
- Good Rx level
- Weak Ec/Io
- No dominate pilot
- High call drop rate
- Frequent Hand-off
66


Figure 9.2 To remove above Shrinking Area, Repeater installed

9.2 TYPES OF REPEATERS
RF Repeaters:
RF stands for Radio Frequency as the transmission path between the donor BTS and the
Repeater is used in RF Repeater system. No wires are used for this path. RF repeaters can be
divided into two types with respect to whether donor link frequency is same to service signal
frequency or not, On-frequency and frequency conversion type.
On-Frequency Repeaters:
A repeater is, in a simplified view, a bi-directional amplifier with filters that amplifies weak
signal in both paths, down link and up link. There is no change between input and output
frequencies of on-frequency repeater. Type of repeaters are classified as broadband, band
selective or channel selective by method of the filtering processes for limiting frequency
bandwidth and removing spurious.
On-frequency repeater plays a role of extending the outdoor coverage of a Macro-cell. The
repeater is installed at the coverage border of the donor BTS cell where the mobile user
receives signals close to the acceptable level and re-transmits the amplified signal to
additional coverage to extend.

67


Figure 9.3 Setup of On-frequency repeater:

In the downlink path, an antenna receives signals from a donor BTS. The link antenna is
connected to the input of the repeater. The signals are filtered, amplified and transmitted into
the service area via a service antenna. The uplink path of the repeater works in the same way.
The service antenna takes up signals from mobile stations within the service area and re-
radiates the amplified signals through the link antenna to the donor BTS.
Broadband RF Repeaters:
The filters in a broadband RF repeater are designed to cover the whole actual operating RF
band. The filtering and amplification are on the RF band. Band pass filters of RF band are
used of which filtering characteristic meets minimum requirements for operating. The
broadband RF repeaters are installed in areas with low traffic and where the risk for
interference with users directly outside the band is low. The broadband RF repeaters have
generally lower gain and lower output power. Propagation delay time in RF band pass filter is
short as less than 1 microsecond.
Band Selective RF Repeaters:
The incoming RF signals are down-converted to an intermediate frequency (IF) with filters
that more sharply and effectively blocks signals directly outside the actual band. The band
selective RF repeater handles a defined specific band within the total operating band, and any
frequency or any numbers of FA can be handled in specific band without changes on
hardware. The SAW filter is used as filtering and time delay is generally around 5
microseconds.

68

Channel Selective RF Repeaters:
A channel selective RF repeater is equipped with a number of one channel up-down
converter units. The incoming RF signals are down-converted to an intermediate frequency
(IF) with filters that more sharply and effectively blocks any signals directly outside the
specified channels bandwidth in operating band. IF SAW filter is used as filtering process
and time delay is generally around 5 microseconds. The number of channel up-down
converter units shall be equal to (or more than) the number of carriers that the operator wants
to use.

Example of Repeater solution with low o/p power repeater:

Figure 9.4 Repeater installation for low o/p power

Another type of repeater is low power and low cost repeater. This type of repeater is
available with 15 dBm, 17dbm and 27 dBm gains and is employed for providing in-building
solutions. Premises such as basement, tunnel, go down, operating rooms in industries and
some type of closed offices remain uncovered from coverage of BTS due to the shadow
effect.
In such type of buildings it is necessary to provide coverage inside the premises by means of
low power repeater. Low power repeater receives signals from nearby donor BTS and
amplifies it and then provides it inside the building with the help of panel antenna. The panel
antenna and repeater module are mounted on the wall inside the structure where the coverage
is to be provided. Depending on the area and geographic condition the antenna with suitable
gain in selected ex. 15 dBm, 17 dBm.
To install the yogi antenna intensity of the coverage is checked on the terrace with CDMA
monitor and then yogi is located at proper point.
69

9.3 FIBER OPTIC REPEATER
Another basic type of repeater is the Fiber Optical repeater. The transmission path between
the donor BTS and the repeater is fiber optic cables. Optical repeater first convert RF BTS
signal into fiber optic signal & transmit the converted signal afterwards retransmit the RF
signal at remote.
Fiber Optical repeater system also provides,
effective solution for extending cell coverage,
Solving multi PN problem and eliminating shadow areas instead of BTS.
Seamless service provided into the rural area and on highway.
The system consists of Master unit and Slave unit, and installation of fiber optic cable
between Master unit and Slave unit is required. The forward link signal of BTS is coupled to
the master unit and translated into optic wave in Master Unit. The optic wave goes through
optical cable to the Slave unit. Slave unit translates optic signal to service RF signal again
and radiates the RF signal to desired service area. Reverse link signal from mobile handset is
picked up by service antenna of Slave Unit and translated into optic wave. The optic wave
goes through optical cable to the Master Unit. Master unit recovers optic signal to reverse
link RF signal and feeds RF signal to Receiver stage of BTS. By using different Medias for
service and link signal, RF and optic wave.
Fiber optical repeater system can have extreme isolation between input and output stage.
Stable and high power of repeater system can be achieved by such a concept of optic
conversion. Time delay of optic wave propagation in optic cable is longer than that of air.
Consideration should be taken carefully to deploy this type of repeater system.
Merits:
No limit of FAs
Long link distance
Not degrade the BTS performance
High reliability which has excellent electrical characteristic



70



Figure 9.5 Set up of optical repeater:

Demerits:
High rental cost using Optical Fiber
FOR Configuration:
MU (Master Unit)
OFD (Optical Fiber Distributor)
SU (Slave Unit)
FOR Total Path Connection:
Forward Path
MU ~ Patch chord ~ OFD ~ Optical Link ~ OF ~Patch chord ~ SU
71

Reveres Path
SU ~ Patch chord ~ OFD ~ Optical Link ~ OFD ~ Patch chord ~ MU
9.4 FREQUENCY SHIFT REPEATER
Frequency Conversion Repeater system provides effective solution for extending cell
coverage, solving multi PN problem and eliminating shadow areas. The system consists of
Donor unit and Remote unit, and assignment of additional link channel between Donor unit
and Remote unit is required.
The down link signal of service channel frequency from BTS is translated to the link channel
frequency and transmitted to the Remote unit by Donor Unit. Remote unit translates link
channel signal to original service channel frequency and radiates the signal to the mobile
handset.
The reverse link signal of service channel frequency from mobile station is converted to the
link channel frequency and transmitted to the Donor unit by Remote unit. And Donor unit
translates link channel signal to service channel frequency and feeds to the BTS coupling
port. The empty channel in the Permitted band is used for assigning link channel.
By using different frequencies for link and service channel, frequency shifting repeater
system can have higher isolation and higher gain than on-frequency repeaters. Stable, longer
distance and higher power of repeater system can be achieved by such a concept of frequency
conversion. The system handles the signal processing by channel conversion unit and low
frequency SAW filter is adapted for filtering channels of which delay time is around 5 to 13
microseconds











72

Figure 9.6 Set up of frequency Shift Repeater:
Merits:
Utilize unoccupied FA as link FA
High antenna isolation between a link antenna & service antenna is not required
Demerits:
Limited service FA
Likely to degrade performance of a BTS due to using adjacent FA

SR Total Path Connection:
Forward Path
DU ~ Link antenna cable ~ Link antenna (Donor site) ~ RF link ~Link antenna
(Remote site) ~ Link antenna able ~ RU.
Reverse Path
RU ~ Link antenna cable ~ Link antenna (Remote site) ~ RF link ~ Link antenna (Donor
sit) ~ Link antenna able ~ RU.

Site Selection condition for FSR:
Recommendation to choose installation location as below; Ensure that link loss between
Donor Unit site and Remote Unit site is no more than 17kms.
Easily installed antenna with proper height
Less interference from other BTS Cells
Easy access and maintenance of the equipment
Avoiding direct sunlight to protect equipment
73

Easy access to electrical power
Figure 9.7 connection between BTS and FSR

9.5 IBS (IN BUILDING SOLUTION)
Introduction:
IBS is stands for IN BUILDING SOLUTION, as the name implies we are using IBS for to
recover poor coverage in the congested indoor areas. We are providing IBS service to those
service users whose monthly revenue of used service is very much high. So generally, we are
providing this service to the small scale and big scale based companies, in which all of the
users use mobile phone service, which are provided by us.

Three basic equipments are used for IBS, which are Out Door pick up antenna, Repeater and
Indoor antenna. Here Yagi antenna used as outdoor picks up antenna. And Panel antenna,
Omni antenna used as an indoor antenna. Panel used for a small cabin while omni antenna
used in large hall. IBS connection flow is shown in below diagram.









74















Figure 9.8 repeater block

Survey:
If the company decided to establish the new BTS tower than before that, survey of the
particular area is required.
In the survey, we use the GPS antenna, by which we can note down the latitude and
longitude position of the particular point.
We have to determine height of tower, orientation of antenna to be mounted on that tower
according to clutter of area.
During the survey, we must keep in mind that the distance between the two BTS tower is
not too large or to small.
If the distance between the two towers is so large than the signal can be weak and
coverage might be poor in between and if distance is less than the it will be wastage of
resources in addition to interface between two channels can be possible.
Equipments used in IBS:
Indoor antenna
Outdoor antenna
Repeater
75

RF cable
Connectors
Splitter

C

Figure 9.9 Outdoor Yagi antenna Figure 9.10 Omni Directional, Panel antenna


These are the two types of antenna which is used as a indoor antenna:
Panel antenna generally used in small cabin or small room type area,
Omni antenna used generally used at large hall type area. Above figure shows both
type of antenna. For IBS the setup is as shown in below figure. At the field we use
following set up. The procedure for the same is as follows:










76






















Figure 9.11 Set up Of IBS (In Building Solution)

Procedure:
Step1:
First by using calibrated CDMA phone we check which are PN we getting at that particular
place where we are going to use IBS solution, then we check that which PN giving us better
CDMA parameter performance. According to that conclusion we clamp our Yagi pick up
antenna on the terrace to fetch that particular PN coverage.
Step2:
Yagi
Anten
na

repeat
er
Panel
or
Omni
Antena
na
Panel
or
Omni
antena


Anten
na
spliter
77

After getting better coverage signals through pick up antenna we route those signals through
RF cable to the repeater, here repeater amplifies those signals up to required level and then
fed it to the indoor panel antenna.
Step3:
Here panel indoor antenna re radiate it in the indoor locations where we need to give good
coverage.
Step4:
Sometimes we keep more than one panel indoor antenna inside the building to give better
coverage at different places, so at that time we are using splitter to split signals for to give
each indoor antenna.

























78

CHAPTER 10
WIRELINE PRODUCTS
Wireline Line products are:
Primary Rate Interface (PRI).
Basic Rate Interface (BRI).
Leased Line (LL).
Internet Lease Line (ILL).
Digital Loop Carrier (DLC).
National Private Lease Circuit (NPLC).
Multi Protocol Label Switching (MPLS).

10.1 PRIMARY RATE INTERFACE (PRI)
This is a special service provided to commercial customers. It is a high value service. Call
centers, Hostels, and all the big offices need many phones with intercom facility. So PRI
provides this service.
To provide the PRI service, one special card called a PRI card is kept in the DLC. It also uses
the E1 technology for communication. At the customer end, this E1 line gets terminated in
their EPBX (Electronic Private Branch Exchange). There are 8 maximum possible customers
in one card, and each can get a maximum band width of 2 Mbps.
In E1, 2 slots are reserved. So we are left with 30 slots. So PRI can connect 30 fixed line
phones at a time.
If a customer needs more than 30 numbers, 2 slots of a card is given to customer. But pilot
number is kept same as much as possible.
When a user takes PRI service, he is allotted a pool of numbers containing 30 numbers in a
pool ideally. There is one master number, which is common for all the phones. The first 4
digits are master number. Then the number varies inside the group.
Facts:
1. When any call is made inside the group, we just have to dial the digits after master
number. And only the digits, after master number appears on the receivers phone.
2. When we make a call outside the group, we have to dial the whole number. But, on
the receivers side, he will get the first number of the pool.
79

3. When any user calls from outside, he will have to dial the precise number, in order to
reach to a particular user.
10.2 BASIC RATE INTERFACE (BRI)
This service is used for customers who, has less equipments to be connected, but importance
of each is high.
To give BRI service, one BRI card is kept in the RT. It can serve up to 8 customers. It also
uses E1 technology to get the connectivity. The range of this is also 300 meters, since E1s
range is 300 meters only.
The ISDN Basic Rate Interface (BRI) service offers two B channel and one D channel
(2B+D). BRI channel service operates at 64 kbps and is meant to carry user data; BRI D
channel service operates at 16 kbps and is meant to carry control and signaling information,
although it can support user data transmission under certain circumstances. So for BRI
service 144 kbps bandwidth is given. From this bandwidth, 16 kbps is used for signaling and
synchronization and remaining 128 kbps is divided into 2 slots of 64 kbps. We can connect
either 2 computers with it to get the data service, or can connect one computer and one phone
or 2 phones also.

10.3 LEASED LINE (LL)
It is used for point to point link.
Typically, leased lines are used by businesses to connect geographically distant
offices.
Unlike dial-up connections, a leased line is always active.
The primary factor affecting the monthly fee is distance between end points.

80


Figure 10.1 Leased Line
10.4 NATIONAL PRIVATE LEASE CIRCUIT (NPLC)
Features are same with Leased line but it will connect inter circle locations.


Figure 10.2 NPLC

10.5 MULTI PROTOCOL LABEL SWITCHING (MPLS)
MPLS is a highly scalable, protocol independent, data-carrying mechanism.
81

MPLS network, data packets are assigned labels. Packet-forwarding decisions are
made completely on the contents of this label, without the need to examine the packet
itself.
When you have multiple branches across a state or a country, you would definitely
want to connect all these branches together to facilitate data transfer/ access between
them in order to accelerate the speed of business transactions.

10.6 INTERNET LEASED LINE (ILL)
It provides permanent, reliable, high-speed connectivity as compared to the temporary
connectivity of dial up access.
The quality of the connection is far superior to what is normally available through
dialup, because of the digital signaling, less noise, fewer exchanges etc.


10.7 DIGITAL LOOP CARRIER (DLC)
Digital loop carrier (DLC) is equipment that bundles a number of individual phone
line signals into a single multiplexed digital signal for local traffic between a telephone
company central office and a business complex or other outlying service area. Analog voice
calls are combined into a single signal and transmitted over a single copper T-carrier system
or E-carrier line, an optical fiber cable, or a wireless connection. In a home, business, or
other installation using digital loop carrier, the analog phone lines of individual users are
connected to a local DLC box which then converts the analog signals into digital and
combines (multiplexes) them into one signal that it sent to the phone company's central office
on the single line. Thus DLC serves bridge between Backbone network and customers
premises.
In competitive era, for a telecommunication provider to remain a provider of choice, require
end to end infrastructure must be reliable and survivable while providing the required band
width / services & should be cost effective.
Digital loop carrier (DLC) technology was started in the early 1970s as a cost-effective
method for providing voice services.
Also known as Access Node (Network).
82

CTs are in Control of the Local Exchange.
RTs are in Control of the CT.
Type (Wall Mount, Indoor, Outdoor)
Currently, the DLC market is evolving rapidly with new DLC
Broadband Loop Carriers (BLCs)
As well as third-generation (3G) DLCs
Basic Connectivity

Figure 10.3 Basic Connectivity
Responsibility
CT .
Physical connect to each subscriber
It has maintenance and testing capability
Signaling detections for RTs
83

Signaling generations for RTs
Message/Alarm receiving and display.
Responsible for Link Status (NMS)
LE .
Incharge of call processing. (LE to COT)
Resp. for forwarding dial tone to subscriber.
Resp. for billing/charging mechanism of each subscriber.
Resp. for Sub Database and Facility management.
Resp. for Announcement generation.
Effects
Benefits.
To reduce copper cable pair requirements.
Overcome electrical constraints.
Save Expense due to cable cost and the associated labour, installation work.
Quick provisioning of multiple service.
Cost + Space effective solutions.
Effective use of available resources.
Issues can be.
Dependent on Local Exchange. (Sub Data, Centrex, Dial tone, etc)
Can lead to multiple subscriber outage.



84

10.8 POINTS OF DIFFERENCE BETWEEN DLC AND EPBX
OPTIONS DLC EPBX
Dial Tone No Dial Tone (dep. LE) Possible
Centrex / Internal
Calling
Not Possible (dep. LE) Possible
External Calling Not Possible (dep. LE) Not Possible (dep. LE)
Sub. Line Provision Possible (dep. LE) Possible (dep. LE )
During Link Failure Calling get's stop Only outer calling get's stop
Time Slot Usages Require while Int. & Ext calling Only while external calling
Individual Line Feature
(call waiting, fw, div etc)
Possible (dep. LE)
Not Possible
(Apply to whole Range (DID)













85

CHAPTER 11
CONFIGURATION OF MUX

11.1 BG-20 CONFIGURATION PROCEDURE


Fig 11.1 BG 20 B
Change IP address of your PC to last four digit of serial no. (make sure it is 1 less or
more then original)
E.g. if your IP is 192.100.45.37 and last four digit of your serial no is 6296 then
change your IP to 192.100.62.97 or 192.100.62.95
Enter in BOOT CONFIGURATION TOOL.
Enter IP (last four digit are serial no) e.g. if serial no is 6296 then IP is
192.100.62.96
And before Click on OK, power OFF the mux and then ON when orange LED blink
which is called minor mode and at that time click OK.
Click on BASIC PARAMETER CONFIGURATION then enter GET and APPLY so
we get the NEID number and IP, if we want to change the IP and NEID to use the
mux at different location we change it from here.
Click on DOWNLOAD EMBEDED SOFTWARE
Select UPPER BANK.
Select latest embedded version file and then DOWNLOAD and APPLY.
Select LOWER BANK.
Enter DOWNLOAD and APPLY.
Exit.
Now, for Login in mux we have to change IP of PC to 194.194.194.194.
Enter in LCT-BGF software for BG-20 mux.
Enter IP 194.194.194.193 is the default IP of mux and password (sdh123456).
86

Click on ADVANCE->REQUEST LOGIN AS MASTER
Click CONFIGURATION -> NE TIME, enter GET and APPLY.
Click CONFIGURATION -> NE ATTRIBUTE
Change NAME, LOCATION etc and then APPLY.
Click CONFIGURATION -> NE CONNECTION SETTING, Enter GET and
APPLY.
Click CONFIGURATION -> SLOT ASSIGNMENT.
Select PHYSICAL and then click on GET PHYSICAL CARD and then click on
APPLY.
Select LOGICAL and then click on GET & APPLY.
Click on XC -> DCC XC
In A1 SAM select MDCC & COM_MDCC1 then click on ADD ITEM
In A2 SAM select MDCC & COM_MDCC2 then click on ADD ITEM
Then click on ACTIVATE
Click on CONFIGURATION -> ANY CONFIGURATION DATA MANAGER ->
FULLY UPLOAD
Right click on MXC CARD -> DOWNLOAD EMBEEDED SOFTWARE, Enter
GET (version should be same).













87

11.2 SNAPSHOTS OF THE CONFIGURATION PROCEDURE:





88





89





90





91


















92

CHAPTER 12
MEASURING EQUIPMENTS

There are many measuring equipments used in transport, such as, OTDR (Optical Time
Domain Reflecto meter), Multi meter, E1 tester, Power meter etc.

12.1 OTDR (OPTICAL TIME DOMAIN REFLECTOMETER):
This equipment is mainly used when there is a cut in fiber. In this equipment a laser is
transmitted through fiber and the distance is calculated where the cut is there with the help of
time delay between transmission and received reflected wave.


Fig 12.1 Optical Time Domain Reflectometer (OTDR)

The OTDR is used for making single ended measurements of optical link characteristics such
as:
1. Fiber attenuation
2. Connector and splice losses
3. Reflectance levels from link components
4. Chromatic dispersion
5. Locate fiber breaks quickly and accurately.
93

OTDR Trace:

Fig 12.2 Screen indicating various parameters

Vertical axis is logarithmic and measures the returning (back reflected) signal in
decibels.
Horizontal axis denotes the distance between the instrument and the measurement
point in the fiber.

Performance Parameters of an OTDR:
Dynamic range:
Difference between the initial back scatter power level and noise level after 3
minutes of measurement time.
Provide information on the maximum fiber loss that can be measured and denotes
the time required to measure a given fiber loss.
Expressed in decibel of one way fiber loss.
Measurement range:
Identifies number of events in the link, such as splice points, connection points, or
fiber breaks.
Defined as maximum allowable attenuation between an OTDR and an event that stills
enable the OTDR to measure the event accurately.
0.5 dB splice is the acceptable event.

94

12.2 OPTICAL POWER METER (OPM)
This equipment is used when there is power related problem. This is mainly used for power
measurement, attenuation testing, if any fiber loss is there etc. It has four parts:
1. Protective cover
2. Adapter, where patch code is connected for measuring power.
3. Display, displays power in dB or dBm.
4. Keypad, used for on/off, changing wavelength, changing in dB or dBm.








Fig 12.3 Power meter

It supports two wavelength, one of 1310 nm and other of 1550 nm.


Fig 12.4 Power measurement Fig 12.5 Attenuation measurement

For measuring power this equipment is connected with the equipment for which the power
measurement is carried. In this adapter is connected to the equipment TX, from where we get
the power received by equipment.

95

In attenuation measurement, equipment sensitivity is measured. In this test, a variable
attenuator is used to find sensitivity. A variable attenuator is connected between power meter
and equipment. Now power is transmitted through patch code and received power is
measured at equipment. This process is carried until we get loss at equipment. When loss is
found, the power is noted and accordingly equipment sensitivity is measured.

12.3 E1 SERVICE TESTER (EST)
This equipment is designed to provide all the test functions required by engineers installing
and maintaining SDH systems in the Access Network. It can be fitted with the optical and
electrical interfaces listed below. It has independent transmitters & receivers for connection
to the following interfaces:

SDH:
STM-1 electrical line interface
Optional STM-1 optical interfaces, 1310nm and/or 1550nm wavelengths
Optional STM-4 optical interfaces, 1310nm and 1550nm wavelengths



Figure 12.6 E1 Service Tester (EST)

PDH:
E4 electrical line interface, 140 Mbit/s
DS3 electrical line interface, 45 Mbit/s
E3 electrical line interface, 34 Mbit/s
E1 electrical line interface, 2048 Kbit/s (balanced and unbalanced)
96

When any E1 is established it is tested with this equipment. If the E1 is working properly, it
will show OK on screen. If not then it will give error accordingly. Other parameter such as
LOS, LOF, data rate, Power level etc can also be measured with help of this equipment.

12.4 VSWR METER

The VSWR meter measures the standing wave (a single-frequency mode of vibration of a
body or physical system in which the amplitude varies from place to place) ratio in a
transmission line in order to check the quality of radio equipment. The meter refers to the
match between the antenna and the transmission line. A VSWR meter should be installed
near the antenna to avoid loss of transmission, which happens because transmission lines
have a certain amount of loss. The reflected power travels back to the cable, producing a low
reading on a VSWR meter.
"VSWR" stands for Voltage Standing Wave Ratio. It is an RF (radio frequency) signal
source, a coaxial cable (i.e., a transmission line that consists of a tube of electrically
conducting material surrounding a central conductor held in place by insulators) with some
sort of mechanism to allow access to the center conductor at various lengths, load impedance
for the other end of the coaxial cable, and some kind of meter to be able to measure the RF
voltage as a probe selecting various points along the coaxial cable. The VSWR is a measure
of impendence mismatch between the transmission line and its load. A transmission line can
be defined as a device which transmits or leads energy from one point to another. The desired
outcome is the highest efficiency. The intention is to diminish the loss through heat and
radiation at its maximum.
The voltage component of a standing wave in a transmission line consists of forward wave
superimposed on the reflected wave. The signal source is generally set to a fixed frequency
and is tuned up for a good output voltage.
An ideal system would transmit energy without any loss along the way. This requires an
exact match between the source impedance, the characteristic impedance of the transmission
line and all its connectors as well as the loads impedance. The signals AC (alternate current)
voltage will be the same from end to end since it runs through without interference.
97


Figure 12.7 VSWR Meter

12.5 ETHERNET TESTER
Whenever customer requires Ethernet output then we use Ethernet Tester. In this we set data
rate as per the requirement of customer and machine transmits set data rate signal. We have
to give soft loop at another end. Our NMS team does this activity of giving soft loop and we
can receive data as per transmitted data rate if our transmission media is ok. Else we get
some data loss. In this way we check if Ethernet link is working properly or not.


Figure 12.8 Ethernet Tester


98

CHAPTER 13
TROUBLESHOOTING

1. PROBLEM:
Coverage issue
SOLUTION:
We had visited a site at Vapi where a yarn company had demanded for the coverage as the
coverage was very weak i.e. next to negligible in that area. The company was situated at a far
away distance from the main city location so signal strength was very poor. We asked if we
can install a BTS site in their premises, so that the nearby area can also be served. But they
refused for this.
Other option was to install a repeater in that premise. So we checked the RSSI and PN using
CDMA mobile phone. RSSI strength was proper and then PN was checked. The received PN
was verified and it was deduced that the received signal was of Maharashtra BTS. PN is a
pilot number which is unique for each BTS and from the PN code we can know about the
donor BTS of the received signal. CDMA mobile was also receiving other signals of different
PNs which were of Gujarat BTSs. But their RSSI was very poor. So we checked RSSI and
PN outside of the compound and we got nearly sufficient RSSI with PN of BTS of Haria
Park (site situated at Vapi).
We installed a Yagi antenna as a receiving antenna and connected it to the repeater, which
was installed inside the building. Then the received signal from the repeater was divided
using splitter. The splitted signal was used to provide coverage in four different rooms using
panel antenna. Panel antenna is used as transmitting antenna.

2. PROBLEM:
Link was down and all the services were closed down.
SOLUTION:
We have a ODU and IDU unit. IDU is at the base and ODU is connected at the top of the
building. Alarm was seen at IDU that was ODU link alarm. So we logged into the software
named RADWIN. In this we saw that frequency was changed from previously being set so
we reset the frequency by using this software. But problem was not yet solved so we went to
another BTS site to check the connection between ODU and BTS.
99

This site was located at LOS of the customer end where problem had occured. There we
found the cable broken between ODU and BTS. It was repaired. Then here also the frequency
was reset. And the link came up.

3. PROBLEM:
Problem in AC to DC convertor.
SOLUTION:
Here, at this site we had given 3-E1s through PRI. Due to large increase in voltage, the
convertor was short circuited. So the services were interrupted. The converter unit was
replaced with another. And the services started again.

4. PROBLEM:
LOS was not clear
SOLUTION:
We had provided Lease Line (LL) service at a site in Daman. It was a leading bank. This site
was not getting proper service as LOS was not clear. Initially when the site was installed,
there were no obstacles between BTS site and Customer site. But as the time elapsed,
obstructions like long trees had grown up. They could not be cut down. So another option
was to rotate antenna a little or rather shift antenna so that it can receive microwave signal
from the BTS site. NEC IDU was connected here. We logged into it and then shifted antenna
and checked for various angles of rotation. The angle for which maximum RSSI was
achieved, at that angle we kept the antenna. And the service started again as it was working
previously.

5. PROBLEM:
Signal received was weak.
SOLUTION:
TTSLs main fiber is running from Surat to Valsad. At the main site at Valsad in Gundlav, the
received signal through fiber was weak due to long distance between fiber ends. So for
amplification of the signal, we had inserted a booster card. This card works same as a
repeater. This card is named as MO_DC_BAS. After this card was inserted, signal strength
was measured by Optical Power Meter (OPM). It was within the acceptable range.
100

6. DEMAND FOR PRI SERVICE:
At another site a customer had demanded for PRI services. So we had to install a new site
over there. This site was demanding for a SDH service. So we had to install the whole
hardware including MUX also.
PRI service is basically providing E1 for voice calls only. So there we first installed the
whole hardware consisting of MUX, DDF, FMS etc. FMS port which has to be connected to
the input of the MUX, is predefined by NMS. So we connect the FMS port to the MUX by
patch code which is optical input to the MUX. Then electrical output from MUX is given to
DDF. From there PRI service is provided.
We also use AC to DC converters to provide power supply to the equipments.





















101

CONCLUSION

During the duration of my training at TATA TELESERVICES LTD., I was involved in
TRANSMISSION Department. I have learned many things as my first step towards Telecom
industries, regarding mobile communication and Internet.
It is really a great advantage for me that I got opportunity to work on a live system in such a
good organization. I learned about the telecom network and how practically the telecom
industry works. I have learned different equipments used in TRANSMISSION such as
MUX, Microwave IDU, ODU, installation of link between two end, DLC (Digital Loop
carrier) and Lease Line services. I have also learned how to configure and manage these
equipments using software. I have also seen how this whole system is monitored using
software Lightsoft. I got opportunity to practically get interacted with BTS. Most of the
knowledge I gained was because of troubleshooting at various sites and obtained practical
experience from this itself.
I also become familiar with industrial environment. I really enjoyed working with this team. I
have learnt many new things here. This development helped me to improve in me qualities
such as time management, sincerity and scheduling.















102




REFERENCES
Books
Wireless Communications, Principles and Practice, by Theodore S. Rappaport
Modern Analog and Digital Communication, by B. P. Lathi
Benefits of Soft Switch Concept by TATA product Description Manual

Websites
1. www.ecitelecom.com/ouroffering/products/pages/BG-20b.aspx