Вы находитесь на странице: 1из 1

Design of Micropile

GEOPROFOUND ENGINEERING SDN BHD

PILE CAPACITY Design using SPT Values


Round Pile =

1000 mm

Skin Area per m, As=

3.142

Base Area, Ab =

Factor of Safety (FoS) =


Depth
Interval (m)

Avg SPT
Value, N

1
2
3
4
5
6
7
8
9
10
11
12
13.5
15
16.5
18
19.5
21
23
24

11
11
2
2
2
13
26
21
21
1
12
5
6
6
1
3
1
2
2
2

0.785

m2

2.000

Unit
Pile Allowable
End Bear at Pile Ultimate
End Bear at depth,
Skin
Skin
Cumulative
Fric, fs Fric, Fs Skin Fric, Fs qb=min(400N/3, 10000) depth, Qb Capacity, Qult = Capacity, Qall =
(kN/m2)
= 2N
(kN)
(kN)
Qult/FoS (kN)
(kN)
Fs+Qb (kN)
(kN/m2)
22
22
4
4
4
26
52
42
42
2
24
10
12
12
2
6
2
4
4
2464.8

69.1
69.1
12.6
12.6
12.6
81.7
163.4
131.9
131.9
6.3
75.4
31.4
56.5
56.5
9.4
28.3
9.4
17.0
22.6
7743.2

69.1
138.2
150.8
163.4
175.9
257.6
421.0
552.9
684.9
691.2
766.5
798.0
854.5
911.1
920.5
948.8
958.2
975.2
997.8
8741.0

1466.7
1466.7
266.7
266.7
266.7
1733.3
3466.7
2800.0
2800.0
133.3
1600.0
666.7
800.0
800.0
133.3
400.0
133.3
240.0
240.0
10000.0

1151.9
1151.9
209.4
209.4
209.4
1361.4
2722.7
2199.1
2199.1
104.7
1256.6
523.6
628.3
628.3
104.7
314.2
104.7
188.5
188.5
7854.0

1221.0
1290.1
360.2
372.8
385.4
1619.0
3143.7
2752.0
2884.0
795.9
2023.2
1321.6
1482.8
1539.4
1025.2
1262.9
1062.9
1163.6
1186.3
16595.0

610.5
645.1
180.1
186.4
192.7
809.5
1571.8
1376.0
1442.0
397.9
1011.6
660.8
741.4
769.7
512.6
631.5
531.5
581.8
593.1
8297.5

07/13/2014