Peak Hour Timer
D. Mohan Kumar
Electrical appliances like refrigerators and air-conditioners consume heavy current if the line voltage drops during the peak
hours between 6 pm and 9 pm. If there is no low-voltage cut-off in these appliances, it will cause wastage of current and
heating of the appliances. Over-heating may, in turn, reduce the efficiency of the compressors of these appliances.
This circuit proves useful here in that it automatically turns an appliance off during the peak hours. After three hours, the
appliance will turn on again.
An LDR-based switch is used for automatic switching off of power to the circuit. During daytime, LDR1 offers low
resistance, so transistor T1 forward biases to pull its collector voltage to the ground and inhibit T2 from forward biasing.
In this state, the remaining circuit is switched off and power to the appliance is obtained from the normally-closed (N/C)
contacts of relay RL1.
When the daylight reduces around 6 pm, LDR1 offers increased resistance and transistor T1 is cut off. Then transistor T2
provides power to the circuit. Using preset VR1, you can adjust the sensitivity of LDR1 for the desired light level.
The timer circuit is designed using the 14-stage ripple counter CD4060 (IC1) to give 3-hour timing by taking pin 1 (Q11) as
the output. When IC1 gets power from transistor T2, it resets through C1 and R3 and starts oscillating. Reservoir
capacitor C2 maintains the voltage to IC1 stable so that the oscillation is not affected by slight variations in the power
supply. Resistor R4 along with capacitor C3 maintains the oscillation of IC1, as indicated by the blinking of LED1 connected
to its output pin 7 (Q3).
The timeout period of the timer can be calculated using the relationship:
T = 2
n
/f
osc
in seconds
where n is the selected output number and f
osc
= 1/2.3(R4.C3)
Hotels in Munnar
www.cleartrip.com/Munnar
Upto Rs 2000 Cashback On Your Hotel Booking. Use Code CTHTLSEM. Hurry!
1
4 1 6
Post Comment | 0 Comments
The latest in SMD LEDs and LED lamps
Top 5 trends in Taiwans electronics industry
New manufacturing facility & solar plants
Tools and Equipment: New products (December 2013)
LED & LED Lights: New products (December 2013)
Resistor R4 is connected to pin 10 and capacitor C3 is connected to pin 9 of IC1. When Q11 output becomes high, diode
D1 inhibits further oscillation of IC1. Q11 output remains high until IC1 resets in the morning.
IC2 is a bistable latch using timer NE555. Its trigger input pin 2 and threshold input pin 6 are tied together so that at
power-on, the output of IC2 goes high and latches since its trigger and threshold inputs are floating. Relay driver
transistor T3 conducts to energise relay RL1 and the appliance, say, refrigerator, is disconnected from mains. This
condition persists for three hours during the peak hours.
After the timeout period of IC1, its Q11 pin goes high to send a positive pulse to the threshold input of IC2 through
resistor R7. This high-going pulse resets IC2 and its output becomes low. Transistor T3 cuts off and relay RL1 de-
energises to turn the appliance on through N/C contacts of relay RL1. Capacitor C4 maintains the base current of
transistor T3 for clean switching and avoiding chattering of the relay. Freewheeling diode D2 removes back emf of the
relay.
Assemble the circuit on any general-purpose PCB and enclose in a suitable cabinet. Relay contacts should have a current
rating that is sufficient to handle the load. Use wires of proper guage for connecting the relay contacts to AC mains wire.
Earth properly and use a three-pin socket to take AC from the unit. Fix the unit at a place where sufficient daylight
illuminates the LDR.

Related Circuits
Water Pump Controller
Views: 15782
Security System Switcher
Views: 7235
Battery-Low Indicator
Views: 11356
Timer for Mosquito Destroyer
Views: 7647
PC Timer
Views: 2492
Electronics Buzz

Share Share Share Share More
Power
Inverters
myluminousindia.
UPS and Inverter for
Commercial use
User Friendly,
Automatic. Buy Now!


Magazines
Electronics for You
LINUX for You
Facts for You
Electronics Bazaar
Portals
electronicsforu.com
efytimes.com
bpotimes.com
linuxforu.com
Directories
Electronics Annual
Guide
Events
EFY EXPO
EFY Awards
EduTech Expo
OSIWEEK Expo
News Verticals
Electronics
Infotech
Linux & Open
Source
Consumer
Electronics
Science &
Technology
BPO
Educational Institute
EFY Techcenter
Kitsnspares.com

Copyright 2012 EFY Enterprises Pvt. Ltd. All rights reserved.
Reproduction in whole or in part in any form or medium without written permission is prohibited. Usage of the content from the web site is subjectT etor ms and Conditions

Вам также может понравиться