Вы находитесь на странице: 1из 4

Three-Phase Control Panels

Applications
Franklins heavy duty three-phase panels are
optimized for water and irrigation applications.
The spacious layout makes installation and
maintenance simple and easy, so theres no
need to spend time wrestling with wires, and
adding components is easy. With a Franklin
three-phase control panel, you can be sure
that your system is set-up according to
Franklins recommendations.
Franklin Electric three-phase control panels
are available from 3 to 200 hp, in ratings from
200 to 575 Volts.

Basic Features

UL approved, heavy-duty NEMA 3R enclosure

Class R fusible disconnect

Service entrance rated

Lightning arrestor

Motor logic or Franklin SubMonitor protected

NEMA contactor

Door wind hinge

Pilot device and alarm terminal block

H-O-A switch

Manual push-to-start switch

Easy hook-up

64

Three-Phase Control Panels


Models
HP

DESCRIPTION VOLTS HZ AMPS

MODEL

WT

200
230
460
575
200
230
460
575
200
230
460
575
200
230
460
575
200
230
460
575
200
230
460
575
200
230
460
575
200
230
460
575
200
230
460
575
200
230
460
575
200
230
460
575
200
230
460
575

281 101 2203


281 101 3303
281 101 4402
281 101 5502
281 101 2200
281 101 3300
281 101 4400
281 101 5500
281 101 2204
281 104 3304
281 101 4402
281 101 5502
281 101 2200
281 101 3300
281 101 4400
281 101 5500
281 104 2206
281 104 3306
281 101 4403
281 101 5503
281 104 2200
281 104 3300
281 101 4400
281 101 5500
281 104 2206
281 104 3306
281 101 4404
281 101 5503
281 104 2200
281 104 3300
281 101 4400
281 101 5500
281 204 2208
281 204 3308
281 104 4406
281 104 5506
281 204 2200
281 204 3300
281 103 4400
281 104 5500
281 205 2208
281 205 3308
281 104 4406
281 104 5506
281 205 2200
281 205 3300
281 103 4400
281 104 5500

56
56
56
56
59
59
59
59
56
56
56
56
59
59
59
59
60
60
56
56
63
63
59
59
60
60
56
56
63
63
59
59
147
145
60
60
150
148
63
59
145
145
60
60
148
148
63
59

MOTOR
LOGIC

3 hp
SUBMONITOR

MOTOR
LOGIC

5 hp
SUBMONITOR

MOTOR
LOGIC

7.5 hp
SUBMONITOR

MOTOR
LOGIC

10 hp
SUBMONITOR

MOTOR
LOGIC

15 hp
SUBMONITOR

MOTOR
LOGIC

20 hp
SUBMONITOR

60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60

6-18
6-18
3-9
3-9
ALL
ALL
ALL
ALL
9-27
9-27
3-9
3-9
ALL
ALL
ALL
ALL
15-45
15-45
6-18
6-18
ALL
ALL
ALL
ALL
15-45
15-45
9-27
6-18
ALL
ALL
ALL
ALL
45-135
30-90
15-45
15-45
ALL
ALL
ALL
ALL
30-90
30-90
15-45
15-45
ALL
ALL
ALL
ALL

HP

DESCRIPTION VOLTS HZ AMPS

MODEL

WT

200
230
460
575
200
230
460
575
200
230
460
575
200
230
460
575
460
575
460
575
460
575
460
575
460
575
460
575
460
575
460
575
460
575
460
575
460
575
460
575
460
575
460
575
460
575
460
575
460
575
460
575

281 206 2208


281 206 3308
281 104 4406
281 104 5506
281 206 2200
281 206 3300
281 104 4400
281 104 5500
281 207 2209
281 207 3309
281 104 4407
281 204 5507
281 207 2200
281 207 3300
281 106 4400
281 204 5500
281 205 4408
281 204 5507
281 205 4400
281 204 5500
281 206 4408
281 205 5508
281 206 4400
281 205 5500
281 207 4409
281 307 5510
281 207 4400
281 307 5500
281 207 4409
281 307 5510
281 207 4400
281 307 5500
281 308 4411
281 307 5510
281 308 4400
281 307 5500
281 309 4411
281 309 5511
281 309 4400
281 309 5500
281 310 4412
281 309 5511
281 310 4400
281 309 5500
2813104412
2813105512
2813104400
2813105500
2813114413
2813105512
2813114400
2813105500

145
145
60
60
148
148
63
63
147
147
145
145
151
151
148
148
145
145
148
148
145
145
148
148
147
147
150
150
147
147
150
150
390
147
393
150
390
390
393
393
390
390
393
393
390
390
393
393
660
390
663
393

MOTOR
LOGIC

25 hp
SUBMONITOR

MOTOR
LOGIC

30 hp
SUBMONITOR

40 hp
50 hp
60 hp
75 hp
100 hp
125 hp
150 hp
175 hp
200 hp

MOTOR
LOGIC
SUBMONITOR
MOTOR
LOGIC
SUBMONITOR
MOTOR
LOGIC
SUBMONITOR
MOTOR
LOGIC
SUBMONITOR
MOTOR
LOGIC
SUBMONITOR
MOTOR
LOGIC
SUBMONITOR
MOTOR
LOGIC
SUBMONITOR
MOTOR
LOGIC
SUBMONITOR
MOTOR
LOGIC
SUBMONITOR

60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60

30-90
30-90
15-45
15-45
ALL
ALL
ALL
ALL
45-135
45-135
30-90
30-90
ALL
ALL
ALL
ALL
30-90
30-90
ALL
ALL
30-90
30-90
ALL
ALL
45-135
45-135
ALL
ALL
45-135
45-135
ALL
ALL
90-270
45-135
ALL
ALL
90-270
90-270
ALL
ALL
90-270
90-270
ALL
ALL
90-270
90-270
ALL
ALL
18-540
90-270
ALL
ALL

65

Three-Phase Control Panels


Three-Phase Control Panel Accessories
Omega CN7500 Digital Reader for PT100 Sensor*

225 552 107

The Omega CN7500 digital reader displays the temperature from Franklin Electrics
PT100. The PT100 is a precision platinum wire resistor that is optional in Franklins sixand eight-inch motors as a temperature input for process control equipment. The CN7500
digitally displays the temperature and can be set for certain temperature ranges. It trips
the panel contactor in an over-temperature condition and resets the contactor once the
temperature returns to the desired level.
See page 74 for PT100 sensor details
* Due to space limitations, only auxiliary contacts and/or padlock attachments are available for NEMA 1 and 2
panels when a PT100 reader is selected.

Control Circuit Transformers


Control circuit transformers convert the supply voltage required to power a piece of
equipment to a voltage that is needed for various control circuits (pilot lights, selector
switches, push buttons, etc.). The line voltage supplying the equipment is converted to
control voltage by the transformer, eliminating the need to bring in a second source of
power. (Note: Fuses are not supplied.)
PART #

NEMA SIZE

PRIMARY

SECONDARY

VOLT AMPS

225552131

240

120

100

225552141

480

120

100

225552132

240

120

100

225552142

480

120

100

225552133

240

120

150

225552143

480

120

150

225552134

240

120

300

225552144

480

120

300

225552135

240

120*

50

225552145

480

120*

50

NOTE:
For additional voltages, please specify both primary and
secondary voltages.
* Equipped with a NEMA rated AC control relay (open
style) with two normally-open convertible instantaneous
contacts (8501 XO20 Relay).

Pilot Lights
Mounted on the enclosure door, the pilot light indicates when power is on/off or when a
motor is in operation. It can easily be seen from the front of the panel. Choose your color
to fit your application.

66

PART #

NEMA RATED

SIZE

LENS COLOR

225552101

Yes

30 mm

Red

225552102

Yes

30 mm

Green

225552103

Yes

30 mm

Amber

225552104

Yes

30 mm

Clear

Three-Phase Control Panels


Three-Phase Control Panel Accessories Cont.
Contacts
When adding control devices, auxiliary contacts may be required. These contacts
mount on the side of the contactor and include one normally-open and one
normally-closed auxiliary contact.

225 552 110

Padlock Attachment for H-O-A Switch


The padlock attachment allows the owner to lock the hand-off auto switch in the on or
off position to prevent tampering with the pump panel.

225 552 105

Analog Style Elapsed Time Meter


The elapsed time meter keeps track of the total running time of the motor in hours. It is
ideal for applications which require routine maintenance.
225 552 171

SubMonitor
See page 68 for details

cUL Rating
Panels can be equipped with the cUL rating to meet Canadian requirements.

225 552 108

67

Вам также может понравиться