Вы находитесь на странице: 1из 68

CATALOGUE

2014 Revision 1.0


UNINTERRUPTIBLE
POWER SUPPLY (UPS)
Protecting Your Data
Your Inspirations. Our Innovations.
Table of Contents
Table of
Contents
About Us - Company Prole
Online UPS
Professional Series (1P/1P) - Tower
Professional Series (1P/1P) - Dual
Master Series (1P/1P) - Tower
Master Series (1P/1P) - Combo
Master Series (1P/1P) - 2-in-1 Rack/ Tower
Master Series (3P/1P) - Tower
Master Series (3P/1P) - Rack Mount
Master Series (3P/3P) - Tower
Power Series
PPM Series
Line Interactive UPS
PRO SFC Series
PRO Series
PRO-L Series
PRO Rack/ Tower Series
Inverter UPS
LCD Inverter Series
Auto Voltage Regulator
PVR Series
DC UPS
PDC Series
PBU Series
Solar UPS
Zonne Series
PPS Series
PCC Series
PSI Hybrid Series
PSI On-Grid Amnets Series
PSI Off-Grid Offnetz Series
PSI Off-Grid Haus Series
PSS Series
Software & Accessories
Appendix
02
04
04
06
08
12
14
18
21
23
25
30
33
33
35
37
39
41
41
43
43
44
44
45
46
46
48
49
50
51
52
53
54
55
59
01
About Us - Company Prole
Our Mission
Accentuate The Best For The E-generation
PROLiNK

aspires to accentuate the best for the e-generation. With technology becoming an essential aspect of
modern living, the e-generation concept has gradually become ingrained in our lives and digital literacy is
becoming more and more commonplace.
PROLiNK products are designed to make technology work for the e-generation. Created with the end-user in mind,
our products are crafted to enhance performance whether you are at work or play our products work harder,
while you work smarter to achieve your desired results with less effort and better efciency.
Providing value to our consumers whether home or business users, remains a rm commitment of PROLiNK.
With its wide range of quality products, PROLiNK makes it easy for home users to nd user-friendly yet affordable
solutions for their technological needs, while business users are assured of reliable and secure solutions for their
network infrastructure.
Our Vision
Ideas, Innovation and Information
PROLiNK

aims to be the key driving force behind technological changes and improvements in both developing
and developed countries. With its strong focus on technology, our team sets high standards for itself in the areas
of innovation, change and improvement so as to provide the next generation of users with products that are suita-
ble for their technology advanced environments.
The small i in PROLiNK represents ideas, innovation and information three key pillars of growth that drive us
towards achieving excellence in our eld of expertise and challenges us to think beyond our usual boundaries.
Fida International (S) Pte Ltd has been a provider of technologically innovative and user-friendly products
manufactured under the brand name PROLiNK

since 1991. With more than two decades of professional


experience in the information communications sector, PROLiNK is now renowned as a specialist in its eld,
especially in the area of Back-up UPS products.
Over the years, PROLiNK has built its presence through a strong foundation of technological leadership within the
South Asian, South-east Asian and Middle Eastern regions and is continuing to build its presence worldwide. With
its current network of sales ofces in more than 20 countries, customers can be assured that PROLiNK is able to
provide the right solutions to meet the needs of both home and business users within each geographical location
both efciently and effectively.
The companys quest for continuous improvement and quality assurance to its customers has earned us the
ISO9001 quality certication since 1999. With its consistently strong commitment to quality, customers can be
assured of they are getting true value - superior quality products at affordable prices.
02
Core Values
Secured Information Management
With more than two decades of professional experience in providing backup power solutions to our customers, we
are able to support our customers with superior technological know-how and expertise, as well as advice on
market trends. At the same time, we are also fully committed to protecting the privacy of our customers and to
manage condential information discreetly.
Innovative Design
Our products are carefully thought out to ensure that each item is designed to meet the needs of our customers.
With the teams solid experience in the UPS market, customers can be certain that our designs are innovative yet
functional, and suitable for each dynamic market that we have a presence in.
Superior Service Standards
Strict and rigorous testing makes up a huge part of our quality control procedures. We ensure that every item
meets our strict standards from the individual components to the actual nished product.
Total Quality Assurance System
Our products go through careful planning and checks at every stage of the production cycle - from the beginning
stages of product design to the manufacturing and nally the actual delivery of the goods. This guarantees that
our customers receive only the best quality goods of high reliability and durability. Our total quality system has
been audited and approved by globally recognized bodies.
Range of UPS
The wide range of our products gives you an innite range of solutions:
1. Online UPS
2. Line Interactive UPS
3. Inverter UPS
4. DC UPS
4. Solar UPS
03
About Us - Company Prole
Online UPS
Professional Series (1P/1P) - Tower
Online Professional Series
1kVA 6kVA
Professional Series (1P/1P) is an advanced yet affordable
single-phase UPS system that uses on-line double conversion
technology. It is designed to protect against power outages,
disturbances and spikes, making them most suitable for voltage
fluctuating environments. This device is able to provide
high-efciency charging with its high input power factor correction.
Professional Series is available in capacities ranging from 1000VA to
6000VA. High voltage battery chargers and battery extension
assembly are made available for longer runtime applications. Users
can also have the option to top-up an additional isolation
transformer to obtain pure and clean power for their sensitive
devices.
True Double-Conversion Online UPS
Wide input voltage range (110~300VAC)
Input Power Factor correction of 0.98
Output Power Factor of 0.80
Generator compatible
LCD User Interface
Choice between RS-232 communication port or USB / RS-232 / AS400 / SNMP interface
Smart battery charger designed to optimize battery performance
Isolation transformer (optional)
Work-Stations Servers Local Area
Network (LAN)
Small Computer
Network
Rear Panel
For 1kVA to 6kVA model
1. Output receptacles
2. AC input
3. Input circuit breaker
4. Network/Fax Modem Surge Protection
5. Intelligent slot for communication port/
SNMP. (standard come with USB port)
6. External battery connection (only available for L model)
7. Output terminal
8. Output circuit breaker
9. Fan
5
6
9
4
3
2
1
5
9
3
2
7
1
8
4
6
PRO901S/L
PRO902S/L
PRO903S/L
5
9
1
8
4
6
2 7
PRO906S/L
04
Online UPS
Full Specications
RS-232 Port (communication interface).
AS-400 Card (External alarm indicator).
SNMP Card for data communication via network connection.
Output Isolation Transformer.
External PDU & Maintenance Bypass Switch. (suitable for UPS up to 3kVA only)
Options
50 or 60Hz
110VAC < Vin < 290VAC @ 50% LOAD/ 168VAC < Vin < 300VAC @ 100% LOAD
208/ 220/ 230/ 240VAC Nominal Voltage
Voltage Range
Nominal Frequency
Frequency Range
Power Factor
40 ~ 70Hz
0.98
6000 VA/ 4800 W Capacity 1000 VA/ 800 W 2000 VA/ 1600 W 3000 VA/ 2400 W
Valve regulated Lead Acid battery (Maintenance free batteries) Type
Capacity
Liner Load
Non-Liner Load
Recharge Time (Typical)
Charging Current
Standard Model
Input / Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
Safety: EN62040-1-1; EMI62040-2; EN62040-3 Regulations
INPUT
MODELS PRO906S/ L PRO901S/ L PRO902S/ L PRO903S/ L
OUTPUT
BATTERY
MANAGEMENT
ENVIRONMENT
PHYSICAL
OVERLOAD
INDICATORS
EFFICIENCY
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB
1.5 seconds >130%
100% < Load < 110%
LCD Display
AC Mode
1% 3%
0.8
Static Regulation
Frequency Range
Frequency
Power Factor
Current Crest Ratio
Voltage Distortion
3% THD
6% THD 7% THD
4% THD
Waveform
1.0 A (max)
47 ~ 53 Hz or 57 ~ 63 Hz
50Hz or 60Hz auto selection
Pure Sinewave
9AH
9 hours recover to 90% capacity
Up to 88%
3:1
10AH
Type
Long-Run Model Capacity
Charging Current 8.0 A (max) 6.0 A (max)
Overload warning only (No shutdown)
110% < Load <130% 30 seconds
Depending on the application
Depending on the application
200/ 208/ 220/ 230/ 240VAC Output Voltage
397145220
17.2
8.9
421 190 318
421190318
28
13.5
426 190 318
426190318
35.3
14.3
<90% non-condensing
0C - +40C
Operation Humidity
Ambient Temperature
45dBA @ 1 Meter Noise Level
397 x 145 x 220
9.3
4.8
Dimension (mm) D x W H
Net Weight (kgs)
Dimension (mm) D W H
Net Weight (kgs)
Standard Model
Long-Run Model
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specications, designs and contents are subject to change without prior notice.
05
06
Professional Series (1P/1P) - Dual
Online Professional Series
1kVA 3kVA
Online True double-conversion
Accepts Ultra Low Voltage inputs for special power environment
Wide input voltage range (88-144VAC and 176-288VAC) at full load
Input Power factor correction of 0.99
Output Power Factor of 0.80
LCD User Interface
Complete galvanic isolation design offers full isolation and complete
common mode noise rejection
Choice between RS-232 communication port or USB / RS-232 /
AS400 / SNMP interface
Professional Series (1P/1P) - Dual is an advanced yet affordable
single-phase UPS system that uses on-line double conversion
technology with 2 different input voltage ranges. It is designed to
protect against power outages, disturbances and spikes, making
them most suitable for voltage fluctuating environments.
Professional Series (1P/1P) Dual is most suitable to be used in
areas that are plagued by voltages that are as low as 100V. With the
advanced double-conversion technology, the dual series is able to
regulate and maintain consistent output even when it is fully loaded.
Also, this device is able to provide full isolation and complete
common mode noise rejection from complementary equipment. The
Dual Series is available in various capacities, ranging from 1000VA
to 3000VA.
Online UPS
Rear Panel
PRO902D S/L PRO903D S/L
Work-Stations Servers Local Area
Network (LAN)
Small Computer
Network
For 1kVA to 3kVA model
1. Output receptacles
2. AC input
3. Input circuit breaker
4. Network/Fax/Modem surge protection
5. Intelligent slot for communication port/SNMP
(standard come with USB port)
6. External battery terminal
(only available for Long-run model)
7. Output terminal
8. Output circuit breaker
9. Fan PRO901D S/L
5
9
9
6
1
2
3
4
5
9
9 6
1
2
9
4
5
9
9
9
8
6
1
2 7
4
07
Online UPS
Full Specications
50 or 60Hz
88VAC ~ 144VAC and 176VAC ~ 288VAC (auto sensing)
208/ 220/ 230/ 240VAC Nominal Voltage
Voltage Range
Nominal Frequency
Frequency Range
Power Factor
45 ~ 65Hz
0.99
Capacity 1000 VA/ 800 W 3000 VA/ 2400 W
Valve regulated Lead Acid battery (Maintenance free batteries) Type
Capacity
Recharge Time (Typical)
Charging Current
Standard Model
Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3 Regulations
INPUT
MODELS PRO901D S/L
2000 VA/ 1600 W
PRO902D S/L PRO903D S/L
OUTPUT
BATTERY
MANAGEMENT
ENVIRONMENT
PHYSICAL
OVERLOAD
INDICATORS
EFFICIENCY
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB/ RS-232
1.5 seconds >130%
100% < Load < 110%
LCD Display
AC Mode
1%
0.8
Static Regulation
Frequency Range
Frequency
Power Factor
Current Crest Ratio
Voltage Distortion
Linear Load
Non-Linear Load 6% THD
2% THD
Waveform
1.0 A (max)
47 ~ 53 Hz or 57 ~ 63 Hz
50Hz or 60Hz auto selection or selectable
Pure Sinewave
9AH
4 hours recover to 90% capacity
Up to 88%
3:1
Type
Long-Run Model Capacity
Charging Current
Overload warning only (No shutdown)
110% < Load < 130% 30 seconds
Depending on the application
4.0 A or 8.0 A (max.)
Depending on the application
208/ 220/ 230/ 240VAC Output Voltage
423 x 145 x 332
426 x 190 x 448
421 x 190 x 448
<95% non-condensing
0C - +40C
Operation Humidity
Ambient Temperature
50dBA @ 1 Meter Noise Level
423 x 145 x 320
26.5 34 56
21.5 23 41
Dimension (mm) D x W H
Net Weight (kgs)
Dimension (mm) D W H
Net Weight (kgs)
Standard Model
Long-Run Model
RS-232 Port (communication interface)
AS-400 Card (External alarm indicator)
SNMP Card for data communication via network connection.
External PDU & Maintenance Bypass Switch. (suitable for UPS up to 3kVA only)
Options
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specications, designs and contents are subject to change without prior notice.
08
Online UPS
Master Series (1P/1P) - Tower
Online Master Series
1kVA 10kVA
Master Series (1P/1P) is a single-phase UPS system that employs a true
online double-conversion technology. It is designed to deliver clean and
high quality electrical power for devices such as small computer centres,
servers, telecom applications, lab testing equipments and industrial
applications. The Master series (1P/1P) comes with a wide input voltage
range that protects devices against outages, disturbances and spikes. In
addition, this device comes with a smart battery charger that optimizes
the battery performance, ensuring longer lasting battery life. High voltage
battery chargers and battery extension assembly are made available for
longer runtime applications. The Master series (1P/1P) also comes in
various capacities ranging from 1kVA to 10kVA to suit your needs.

The 6kVA and 10kVA UPS system comes with 2 additional features; an
internal bypass system and a parallel redundant system. An internal
bypass system allowing continuous power is integrated for convenience
when maintenance is necessary and a parallel redundant system that
allows two UPS models to operate in parallel as backup for each other.
True Double-Conversion Online UPS
Wide input voltage range (110~300VAC)
Input Power Factor correction of 0.99
Output Power Factor 0.80
Generator compatible
LCD User Interface
Choice between RS-232 communication port or USB / RS-232 / AS400 / SNMP interface
Smart battery charger designed to optimize battery performance
Work-Stations Servers Local Area
Network (LAN)
Small Computer
Network
Rear Panel
For 1kVA to 3kVA model
1. Programmable outlets: connect to non-critical loads
2. Output receptacles: connect to mission critical loads
3. AC input
4. Input circuit breaker
5. Network/ Fax/ Modem surge protection
6. Emergency power off function connector (EPO)
7. USB communication port
8. RS-232 communication port
9. SNMP intelligent slot
10. External battery connection (only available for L model)
11. Output terminal
12. Output circuit breaker
13. Fan
PRO802S/L PRO803S/L PRO801S/L
PRO8015S/L
9
5
6
8 7
13
10
4
3
2
1
9
5
2 1
7 8
6
4
3
10
13
13
9
5
2 1
7 8
6
3
4
10
12
11
13
13
09
Online UPS
For 6kVA to 10kVA model
1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Share current port (only available for parallel model)
5. Parallel port (only available for parallel model)
6. Intelligent slot
7. Charger fan
8. Power stage fan
9. Maintenance bypass switch
10. Input circuit breaker
11. Input/Output terminal
12. Output terminal 1
13. Output terminal 2
14. External battery terminal (only available for Long-run model)
15. Utility input terminal
16. Output IEC Socket
9
5 5 2 1
7 8
8
6
4 3
15 12 13
14
16
11
10
PRO806S/L
PRO810S/L
Battery Pack
For 1kVA to 3kVA model
For 6kVA to 10kVA model
Model
Battery Type
Battery Number (max)
Dimension (DxWxH) mm
Weight (kg)
G6
6 pcs
18
6 pcs
397 145 220
20
12 pcs
36
G18 G12
12 pcs 18 pcs 18 pcs
421 190 318
40 55
12V9AH 12V7AH 12V7AH 12V9AH 12V7AH 12V9AH
535 190 318
61
Model
Battery Type
Battery Number (max)
Dimension (DxWxH) mm
Weight (kg)
40 pcs
109
G40 G60
40 pcs 60 pcs 60 pcs
592 250 576
125 166
12V7AH 12V9AH 12V7AH / 12V90AH
830 250 576
190
10
Online UPS
Full Specications
Options
AS-400 Card (External alarm indicator)
SNMP Card for data communication via network connection.
Output Isolation Transformer.
External PDU & Maintenance Bypass Switch. (Only suitable for UPS that are up to 3kVA)
A derate will occur during the Frequency converter mode (Capacity is reduced to 60%) and when the output voltage is adjusted to 208VAC (Capacity is reduced to 80%).
If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered.
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specications, designs and contents are subject to change without prior notice.
50 or 60Hz
110VAC <Vin<290VAC @ 50% LOAD / 175VAC <Vin<300VAC @ 100% LOAD
208/ 220/ 230/ 240VAC Nominal Voltage
Voltage Range
Nominal Frequency
Frequency Range
Power Factor
40 ~ 70Hz
0.99
3000 VA/ 2400 W Capacity 1000 VA/ 800 W 1500 VA/ 1200 W 2000 VA/ 1600 W
Valve regulated Lead Acid battery (Maintenance free batteries) Type
Capacity
Recharge Time (Typical)
Charging Current
Standard Model
Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3 Regulations
INPUT
MODELS PRO803S/ L
6000 VA/ 4800 W
PRO806S/ L
10000 VA/ 8000 W
PRO810S/ L PRO801S/ L PRO8015S/ L PRO802S/ L
OUTPUT
BATTERY
MANAGEMENT
ENVIRONMENT
PHYSICAL
OVERLOAD
INDICATORS
EFFICIENCY
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB/ RS-232
2 seconds >130%
100% < Load < 110%
LCD Display
AC Mode
1%
0.8
Static Regulation
Frequency Range
Frequency
Power Factor
Current Crest Ratio
Voltage Distortion
Linear Load
Non-Linear Load
2% THD 3% THD
4% THD 6% THD
Waveform
1.0 A (max)
47 ~ 53Hz or 57 ~ 63Hz
50Hz or 60Hz auto selection or selectable
Pure Sinewave
9AH 9AH 7AH 7AH 7AH
9 hours recover to 90% capacity
Up to 90%
3:1
9AH
Type
Long-Run Model Capacity
Charging Current 8.0 A (max) 4.0 A (max)
Overload warning only (No shutdown)
110% < Load < 130% 30 seconds
Depending on the application
Depending on the application
200/ 208/ 220/ 230/ 240VAC Output Voltage
397145220
26 28
13
421 190 318
421190318
81
13
592 x 250 x 576
592 x 250 x 576
83
25 27
<90% non-condensing
0C - +40C
Operation Humidity
Ambient Temperature
45dBA @ 1 Meter 55dBA @ 1 Meter 58dBA @ 1 Meter Noise Level
397 x 145 x 220
13 14
7 7
Dimension (mm) D x W H
Net Weight (kgs)
Dimension (mm) D W H
Net Weight (kgs)
Standard Model
Long-Run Model
11
Online UPS
Programmable Outlets (P1)
- connect to non-critical devices
True double-conversion Online UPS
A true double conversion UPS will provide clean, high
level quality power to fully protect mission-critical
devices such as sensitive networks, small computer
centers, servers, telecom applications, as well as for
industrial applications.
Higher Accuracy for Output Voltage
The advanced control rmware allows the Master Series
(1P/1P) to achieve higher accuracy with the output
voltage tolerance of +/- 1%. The device is applicable for
the use with critical test and IT equipments.
Smart Battery Charger Design to Optimise
Battery Performance
Master Series (1P/1P) 1-3kVA models are equipped with
a 2-stage charger design to guarantee precise battery
discharge time. The charging voltage is also
automatically adjusted according to the ambient
temperature, to lengthen the service life of the battery.
The 6kVA and 10kVA models come with an additional
extendable charger that allows for large-capacity battery
charging.
DSP Technology (Applies for the above
models)
A DSP controller improves the performance and
efciency of the UPS.
Maintenance Bypass Available For 6kVA And
Above Models
Internal bypass assures continuous power to critical
devices during UPS maintenance.
Optional Hot Standby and N+X Parallel
Redundant System (Available for Models
ranging from 6kVA and above)
An internal bypass system allowing continuous power is
integrated for convenience when maintenance is
necessary and a parallel redundant system that allows
two UPS models to operate in parallel as backup for each
other.
Output Power factor of 0.8
As compared to the online UPS models in the current
market, the Master Series (1P/1P) provides better output
power factor of up to 0.8. This unit is able to offer higher
performance and efciency for your critical applications.
Wide Input Voltage Range (110 V -300 V)
Master Series (1P/1P) can still provide stable power to
connected devices under unstable power environments.
50/60 Hz Frequency Converter Mode
Lock output frequency at 50Hz or 60Hz to suit power
sensitive equipments.
ECO Mode Operation For Energy Saving
Offers efciency as high as 97% to cut energy usage &
cost. UPS power application via static bypass, timely
returning to online double conversion when the need
arises.
Emergency Power Off (EPO) Function
This feature can protect the personnel and the
equipment in the case of re outbreak or other types of
emergency.
SNMP + USB + RS-232 Multiple
Communication port for Models ranging from 1
to 3kVA.
This feature allows either the USB or RS-232
communication port to simultaneously operate with the
SNMP interface.
Programmable Power Management Outlets
The programmable power
management outlets allow users to
easily and independently control the
load segment. In the event of a
power failure, this feature enables
users to manage and extend the
battery time for mission critical
devices by shutting down the
non-critical devices.
12
Online UPS
Master Series (1P/1P) - Combo
Online Master Series
6kVA 10kVA
True double-conversion on line UPS
DSP technology guarantees high performance
Wide input voltage range (110-300 VAC)
Active input power factor correction of 0.99
Output power factor of 0.8
50Hz/60Hz frequency converter mode
Standard backup UPS and long backup UPS in one integrated unit
Charging current can be adjusted via LCD or software (1A~6A)
Emergency power off function (EPO)
Comes with a USB and PS-232 communication port
Comes with a mini slot for AS-400 / SNMP communication card
Comes with a maintenance bypass function
Work-Stations Servers Local Area
Network (LAN)
Small Computer
Network
Rear Panel
For 6kVA to 10kVA model
1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Intelligent slot
5. Power stage fan
6. Maintenance bypass switch
7. Input circuit breaker
8. Input/Output terminal
9. External battery terminal (only available for Long-run model)
10. Battery Compartment (only available for Standard model)
Master Series (1P/1P) - Combo is a single-phase UPS system that employs a true
online double-conversion technology. It is designed to deliver clean and high
quality electrical power for devices such as small computer centres, servers,
telecom applications and industrial applications. Designed with a small footprint,
this device ensures that it will t into any corner of your small ofce.
Master Series (1P/1P) - Combo series comes with a wide input voltage range that
protects devices against the outages, disturbances and spikes. Fitted with a smart
battery charger design, this device is able to optimize its battery performance,
ensuring longer lasting battery life. High voltage battery chargers and battery
extension assembly are made available for longer runtime applications. The
Combo series are available in the following capacities; 6kVA and 10kVA.
PRO806C/
PRO810C
PRO806CL/
PRO810CL
9
5
6
8
7
4
3 2 1
5
6
8
7
4
3 2 1
10
13
Online UPS
Options
AS-400 Card (External alarm indicator)
SNMP Card for data communication via network connection.
Output Isolation Transformer.
50 or 60Hz
110VAC <Vin<290VAC @ 50% LOAD / 176VAC <Vin<300VAC @ 100% LOAD
208/ 220/ 230/ 240VAC Nominal Voltage
Voltage Range
Nominal Frequency
Frequency Range
Power Factor
46 ~ 64Hz
0.99
Capacity 6000 VA/ 4800 W 10000 VA/ 8000 W
Valve regulated Lead Acid battery (Maintenance free batteries) Type
Capacity
Recharge Time (Typical)
Charging Current
Standard Model
Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3 Regulations
INPUT
MODELS PRO806C/ CL PRO810C/ CL
OUTPUT
BATTERY
MANAGEMENT
ENVIRONMENT
PHYSICAL
OVERLOAD
INDICATORS
EFFICIENCY
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB/ RS-232
1 second >130%
100% < Load < 110%
LCD Display
AC Mode
1%
0.8
Static Regulation
Frequency Range
Frequency
Power Factor
Current Crest Ratio
Voltage Distortion
Linear Load
Non-Linear Load 5% THD
3% THD
Waveform
1.0 A (max)
46 ~ 54Hz or 56 ~ 64Hz
50Hz or 60Hz auto selection or selectable
Pure Sinewave
9AH
9 hours recover to 90% capacity
Up to 90%
3:1
Type
Long-Run Model Capacity
Charging Current 6.0 A (max)
10 minutes
110% < Load < 130% 1 minute
Depending on the application
Depending on the application
200/ 208/ 220/ 230/ 240VAC Output Voltage
360 x 192 x 318
440 x 192 x 688
440 x 192 x 318
<95% non-condensing
0C - +40C
Operation Humidity
Ambient Temperature
55dBA @ 1 Meter 58dBA @ 1 Meter Noise Level
360 x 192 x 688
60 75
21 23
Dimension (mm) D x W H
Net Weight (kgs)
Dimension (mm) D W H
Net Weight (kgs)
Standard Model
Long-Run Model
Full Specications
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specications, designs and contents are subject to change without prior notice.
14
Online UPS
Master Series (1P/1P) - 2-in-1 Rack/ Tower
Online Master Series 1kVA 10kVA
Master Series (1P/1P) 2-in-1 Rack/Tower is a single-phase UPS system that employs a true online
double-conversion technology. This device comes with a practical 2U universal-mount case that provides an
option for the user to either install it as a floor-standing tower or in a mounted position using a 19-inch rack mount
bracket. With its high density output power factor of 0.9, this device is able to provide outstanding performance
and efciency to meet the requirements of a mission critical environment.
This 2-in-1 Rank/Tower UPS is brilliantly designed with a hot-swapping battery feature to facilitate the
replacement of the existing batteries without the hassle of having to shut the devices down. On top of that, models
with a 6kVA and 10kVA capacity comes with a parallel redundant system that allows two UPS models to operate
in parallel and as backup for each other. High voltage battery chargers and battery extension assembly are made
available for longer runtime applications. The PROLiNK 2-in-1 Rank/Tower UPS comes with a wide range of
capacities from as low as 1kVA to as high as 10kVA to accommodate to your every need.
True Double-Conversion Online UPS
Rack or Tower design
Wide input voltage range (110~300VAC)
Input Power Factor correction of 0.99
Output Power factor of 0.90
50/60Hz frequency converter mode
Hot-Swappable battery design
Emergency Power Off (EPO) function
ECO Operation Mode provides energy conservation
Generator Compatible
Option available for long-run models to expand the charger capacity to 8A
Multiple communication interface (SNMP/USB/RS-232)
Smart battery charger is designed to optimize overall battery performance
Selectable output voltage via LCD panel
Work-Stations Servers 19 Rack
Mount
Local Area
Network (LAN)
Small Computer
Network
15
Online UPS
Rear Panel
For 1kVA to 3kVA model
1. Programmable outlets: Connect to non-critical loads
2. Output receptacles: Connect to mission-critical loads
3. AC input
4. Input circuit breaker
5. Network/Fax/Modem surge protection
6. Emergency power off function connector (EPO)
7. USB communication port
8. RS-232 communication port
9. SNMP intelligent slot
10. External battery terminal (only available for Long-run model)
11. Output IEC320-C20 connector
12. Fan
For 6kVA to 10kVA model
1. Programmable outlets: Connect to non-critical loads
2. Output receptacles: Connect to mission-critical loads
3. AC input
4. Input circuit breaker
5. Network/Fax/Modem surge protection
6. Emergency power off function connector (EPO)
7. USB communication port
8. RS-232 communication port
9. SNMP intelligent slot
10. Battery connection
11. Input terminal
12. Fan
13. Parallel port (only available for parallel model)
14. External maintenance by-pass switch connection
15. Output Terminal
16. Ground
PRO806RS/RL
PRO810RS/RL
6
9
4
7
7
12
10 14
13
11 16 15
Battery Pack
For 1kVA to 10kVA model
Model
Battery Type
Battery Number (max)
Dimension (DxWxH) mm
Weight (kg)
G8R
8 pcs
480 438 88
31.1
G12R G20R
12 pcs 20 pcs
43.3 57
12V9AH 12V7AH 12V9AH
580 438 133 600 438 88
63
PRO803RS/RL
5 12 12 10
6
7
8
9
1
2
3
11
4
PRO801RS/RL PRO8015RS/RL PRO802RS/RL
5 12 10
6
7
8
9
1
2
3
4
16
Online UPS
AS-400 Card (External alarm indicator)
SNMP Card for data communication via network connection
MODBUS Card (communication interface)
Universal Rackmount Slider for installation in rack cabinets
External PDU & Maintenance Bypass Switch (Only suitable for UPS that are up to 3kVA)
Maintenance Bypass Switch [MBS] (Only available in UPS ranging from 6 to 10kVA)
External Automatic Transfer Switch (ATS)
Options
Full Specications
50 or 60Hz
110VAC <Vin<290VAC @ 50% LOAD / 170VAC <Vin<300VAC @ 100% LOAD
208/ 220/ 230/ 240VAC Nominal Voltage
Voltage Range
Nominal Frequency
Frequency Range
Power Factor
40 ~ 70Hz
0.99
3000 VA
Capacity Active Power (Standard Model)
Active Power (Long-Run Model)
Apparent Power 1000 VA 1500 VA 2000 VA
Valve regulated Lead Acid battery (Maintenance free batteries) Type
Capacity
Recharge Time (Typical)
Charging Current
Standard Model
Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3 Regulations
INPUT
MODELS PRO803RS/ RL
6000 VA
PRO806RS/ RL
10000 VA
2700 W 900 W 1350 W 1800 W 5400 W 9000 W
2400 W 800 W 1200 W 1600 W 5400 W 9000 W
PRO810RS/ RL PRO801RS/ RL PRO8015RS/ RL PRO802RS/ RL
OUTPUT
BATTERY
MANAGEMENT
ENVIRONMENT
PHYSICAL
OVERLOAD
INDICATORS
EFFICIENCY
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB/ RS-232
2 seconds 1 second >130%
100% < Load < 110%
LCD Display
AC Mode
1%
0.9 @ Standard Model, 0.8 @ Long-Run Model 0.9 for Standard and Long-Run Model
Static Regulation
Frequency Range
Frequency
Power Factor
Current Crest Ratio
Voltage Distortion
Linear Load
Non-Linear Load 8% THD 4% THD 6% THD
2% THD
Waveform
1.0 A (max)
47 ~ 53Hz or 57 ~ 63Hz
50Hz or 60Hz auto selection or selectable
Pure Sinewave
9AH
4 hours recover to 90% capacity 9 hours recover to 90% capacity
Up to 90%
3:1 5:1 3:1 5:1
7AH 9AH
Type
Long-Run Model Capacity
Charging Current 8.0 A (max) 4.0 A (max) 6.0 A (max)
Overload warning only (No shutdown) 10 minutes
110% < Load < 130% 30 seconds 1 minute
Depending on the application
Depending on the application
200/ 208/ 220/ 230/ 240VAC Output Voltage
380x438x88 (2U) 480x438x88 (2U)
20.6 28
11.3
480x438x88 (2U)
600x43x88(2U)
UPS Unit: 17
Battery Pack: 57
UPS Unit: 20
Battery Pack: 63
13.8
Battery Unit:
580x438x133 (3U)
UPS Unit:
580x438x133 (3U)
Battery Unit:
580x438x133 (3U)
UPS Unit:
688x438x133 (3U)
600x438x88 (2U)
580x438x133 (3U) 668x438x133 (3U)
17 20
<90% non-condensing
0C - +40C
Operation Humidity
Ambient Temperature
50dBA @ 1 Meter Noise Level
380x438x88 (2U)
12.9 17.6
8.6 10.7
Dimension (mm) D x W H
Net Weight (kgs)
Dimension (mm) D W H
Net Weight (kgs)
Standard Model
Long-Run Model
L stands for Long-run model
S stands for Standard model
*All specications, designs and contents are subject to change without prior notice.
17
Online UPS
Programmable Outlets (P1)
- connect to non-critical
devices
True Double-conversion Online UPS
A true double conversion UPS system will provide clean
and high quality electrical power to fully protect mission
critical systems such as sensitive networks, small
computer centers, servers, telecom applications and
industrial applications.
Programmable Power Management Outlets
The programmable power management outlets allow
users to easily and independently control the load
segment. In the event of a power failure, this feature
enables users to manage and extend the battery time for
mission critical devices by shutting down the non-critical
devices.
ECO and Advanced ECO Mode for Energy Saving
It allows the UPS to operate in high efciency of up to
97% during energy saving ECO mode and 98% in
operation mode. In the event of an electrical AC failure,
the inverter will automatically step-in and provide
electrical supply to the connected systems.
Emergency Power Off Function (EPO)
This feature provides adequate protection for the user
and the equipment against hazards such as re
break-out or other emergencies.
Hot-swapping Battery Design
The hot-swapping battery feature helps to facilitate the
replacement of the existing batteries without the hassle
of having to shut the devices down.
Long Battery Runtime Models Available
Our Long Battery Runtime Models offers the flexibility to
add-on additional external batteries to provide a longer
back-up time.
User-friendly LCD Display
The front panel digital display comes with an auto-
rotation feature that caters to your installation
preference; either vertically or wall mounted.
Rack / Tower Design
This device comes with a practical 2U universal-mount
case that provides an option for the user to either install
it as a floor-standing tower or in a mounting position
using a 19-inch rack mount bracket.
High Output Crest Ratio
The Master (1P/1P) 2-in-1 Rack/Tower Series is
designed with a high output crest ratio of 5:1 that allows
the device to be extremely compatible with equipment
such as compressors, generators and motors.
Output Voltage Regulation (tolerance +/- 1%)
The Master (1P/1P) 2-in-1 rack / Tower Series is able to
produce extremely stable and clean electrical power with
its high efciency output voltage regulator. This regulator
is able to achieve a tolerance of +/- 1%, making it
extremely compatible even with sensitive power
supplies.
Output power factor 0.9
Master (1P/1P) 2-in-1 rack/Tower Series is a
high-density UPS system with an output power factor of
0.9. With this high power factor, the Master series is able
to provide higher performance to critical applications.
Rack Display
Tower Display
19 Rack-mounting Floor-standing Tower
18
Online UPS
Master Series (3P/1P) - Tower
Online Master Series
10kVA 30kVA
True Double-Conversion Online UPS
DSP technology guarantees high performance
Input Power Factor Correction 0.99
Active power factor correction in all phases
50/60Hz frequency converter mode
Multiple communication interface (SNMP/USB/RS-232)
Wide input voltage range
Output Power Factor 0.80
Comes with a maintenance bypass function
Optional N+X parallel redundancy
Emergency Power Off (EPO) function
Isolation transformer (Optional)
Data
Centre
Electro-Medical
Device
Storage
PLCS
Emergency
Alarm
Devices
E-Business
(Server Farms,
ISP/ASP/POP)
Local Area
Network
(LAN)
Telecommunication
Devices
PRO83110S/L
Rear Panel
For 10kVA model
1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Share current port (only available for parallel model)
5. Parallel port (only available for parallel model)
6. Intelligent slot
7. Charger fan
8. Power stage fan
9. Maintenance by-pass switch
10. Input circuit breaker
11. Output circuit breaker for receptacles
12. Output receptacles: connect to mission-critical loads
13. Input/Output terminal
14. External battery connector (Only available for Long-run Model)
5 5
13
14
12
10
7
8
8
9
6
1 2 3 4
11
Master Series (3P/1P) three-phase input / single-phase output, true online double
conversion UPS system guarantees consistent and quality electrical power to protect
your mission critical applications such as mid-sized business servers,
telecommunication systems and industrial equipment. The (3P/1P) UPS is designed with
a wide input voltage range to handle voltage fluctuating situations and a high accuracy
output voltage to fail-safe your equipment.
This Voltage Frequency Independent (VFI) system is available in capacities from 10kVA to
30kVA. By adopting the latest IGBT technology, this device is able offer excellent voltage
switching characteristics during generator operation. An internal bypass system allowing
continuous power is also integrated for convenience when maintenance is necessary. In
addition, this device comes with a parallel redundant system that allows two UPS models
to operate in parallel and as backup for each other. The Master series (3P/1P) UPS also
offers the option of adding on an isolation transformer to suit your requirements.
19
Online UPS
PRO83115L
PRO83120L
PRO83115S
PRO83120S
PRO83130S/L
PRO83130L
For 15kVA to 30kVA model
1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Share current port (only available for parallel model)
5. Parallel port (only available for parallel model)
6. Intelligent slot
7. Charger fan
8. Power stage fan
9. Maintenance by-pass switch
10. Input circuit breaker
11. Output circuit breaker for receptacles
12. Output receptacles: connect to mission-critical loads
13. Input/Output terminal
14. Output Terminal: Connect to mission-critical loads
15. Programmable Output terminal: Connect to non-critical loads
16. External battery terminal (only available for Long-run model)
17. Utility input terminal
18. Grounding terminal (only available for parallel system)
5 5
11
18
10
7
7
8
8
9
6
1 2 3 4
5 5
11
10
7
7
8
8
9
6
1 2 3 4
For 15K & 30K model For 10K model
14 15 17
15 16 17 14
18
AS-400 Card (External alarm indicator)
SNMP Card for data communication via network connection
MODBUS Card (Communication interface)
Output Isolation Transformer
Options
20
Online UPS
50 or 60Hz
300VAC < Vin < 480VAC
360/ 380/ 400/ 415VAC Nominal Voltage
Voltage Range
Nominal Frequency
Frequency Range
Power Factor
46 ~ 64Hz
0.99
Capacity 10 kVA/ 8 KW 15 kVA/ 12 KW 20 kVA/ 16 KW
Valve regulated Lead Acid battery (Maintenance free batteries) Type
Capacity
Liner Load
Non-Liner Load
Recharge Time (Typical)
Charging Current
Standard Model
Input / Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3 Regulations
INPUT
MODELS PRO83110S/ L PRO83115S/ L PRO83120S/ L
30kVA / 24kW
PRO83130 (S/L)
OUTPUT
BATTERY
MANAGEMENT
ENVIRONMENT
PHYSICAL
OVERLOAD
INDICATORS
EFFICIENCY
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB
1 second >130%
100% < Load < 110%
LCD Display
AC Mode
1%
0.8
Static Regulation
Frequency Range
Frequency
Power Factor
Current Crest Ratio
Voltage Distortion
2% THD
6% THD 5% THD 5% THD 7% THD
Waveform
1.0 A (max) 2.0 A (max) 4.0 A (max)
4.0 A (max) 12.0 A (max)
50 ~ 60Hz 0.1 Hz
50Hz or 60Hz auto selection or selectable
Pure Sinewave
9AH
9 hours recover to 90% capacity
Up to 89%
3:1
Type
Long-Run Model Capacity
Charging Current
10 minutes
110% < Load < 130% 1 minute
Depending on the application
Depending on the application
200/ 208/ 220/ 230/ 240VAC Output Voltage
592 250 576
164
37
815 250 826
592 250 826
234
64
815 300 1000
815 250 826
IP20
<95% non-condensing Operation Humidity
Protection
Ambient Temperature 0C - +40C
Noise Level
592 x 250 x 576
83
28
60dBA @ 1 Meter
Dimension (mm) D x W H
Net Weight (kgs)
Dimension (mm) D W H
Net Weight (kgs)
Standard Model
Long-Run Model
Full Specications
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specications, designs and contents are subject to change without prior notice.
21
Master Series (3P/1P) - Rack Mount
Online Master Series 10kVA 20kVA
True double-conversion
DSP technology guarantees high performance
Output Power Factor 0.8
Wide input voltage range
Active power factor correction in all phases
50Hz/60Hz frequency converter mode
Eco mode operation for energy saving (ECO)
Emergency power off function (EPO)
Generator compatible
Multiple communication interface (SNMP/USB/RS-232)
Adjustable battery numbers
Optional N+X parallel redundancy
Master Series (3P/1P) Rack three-phase input / single-phase output, true online double conversion UPS system
guarantees consistent and quality electrical power to protect your mission critical applications such as mid-sized
business servers, telecommunication systems and industrial equipments. This (3P/1P) UPS is designed with a wide
input voltage range to handle voltage fluctuating situations and a high accuracy output voltage to fail-safe your
equipment.
This Voltage Frequency Independent (VFI) system is available in capacities from 10kVA to 20kVA. By adopting the latest
IGBT technology, this device is able offer excellent voltage switching characteristics during generator operation. An
internal bypass system allowing continuous power is also integrated for convenience when maintenance is necessary.
In addition, this device comes with a parallel redundant system that allows two UPS models to operate in parallel and as
backup for each other. The Master series (3P/1P) Rack UPS also offers the option of adding on an isolation transformer
to suit your requirements.
Online UPS
Data
Centre
19 Rack
Mount
Storage
PLCS
Emergency
Alarm
Devices
Local Area
Network
(LAN)
Telecommunication
Devices
5
12 10
7
8
9
6 6
1
2
3
4 4 4
11
5
12
10
7
8
9
6 6
6 6
1
2
3
4
4
4
11
Rear Panel
For 10kVA to 20kVA model
1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Parallel port (only available for parallel model)
5. Intelligent slot
6. Fan
7. External maintenance by-pass switch connection
8. Input circuit breaker
9. Input/Output terminal
10. Output terminal
11. Battery terminal
12. Input terminal
PRO83110RS/RL
PRO83120RS/RL
22
Online UPS
AS-400 Card (External Alarm Indicator)
SNMP Card for data communication via network connection
MODBUS Card (Communication interface)
Universal Rackmount Slider for installation in rack cabinets
External Maintenance Bypass Switch (Only available with 10kVA model)
Options
Full Specications
50 or 60Hz
300VAC <Vin <480VAC
360/ 380 /400/ 415VAC Nominal Voltage
Voltage Range
Nominal Frequency
Frequency Range
Power Factor
46 ~ 64Hz
0.99
Capacity 10kVA/ 8kW 20kVA/ 16kW
Valve regulated Lead Acid battery (Maintenance free batteries) Type
Capacity
Recharge Time (Typical)
Charging Current
Standard Model
Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3 Regulations
INPUT
MODELS PRO83110RS/ RL PRO83120RS/ RL
OUTPUT
BATTERY
MANAGEMENT
ENVIRONMENT
PHYSICAL
OVERLOAD
INDICATORS
EFFICIENCY
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB/ RS-232
1 second >130%
100% < Load < 110%
LCD Display
AC Mode
1%
0.8
Static Regulation
Frequency Range
Frequency
Power Factor
Current Crest Ratio
Voltage Distortion
Linear Load
Non-Linear Load 5% THD
2% THD
Waveform
1.0 A (max) 2.0A (max)
46 ~ 54Hz or 56 ~ 64Hz
50Hz or 60Hz auto selection or selectable
Pure Sinewave
9AH
9 hours recover to 90% capacity
Up to 89%
3:1
Type
Long-Run Model Capacity
Charging Current
10 minutes
110% < Load < 130% 1 minute
Depending on the application
4.0 A (max)
Depending on the application
200/ 208/ 220/ 230/ 240VAC Output Voltage
668 x 438 x 133 (3U)
UPS Unit: 668 x 438 x 266 (6U)
BatteryPack: 580 x 438 x 133 (3U) x 2
668 x 438 x 266 (6U)
<95% non-condensing
0C - +40C
Operation Humidity
IP20 Protection
Ambient Temperature
58dBA @ 1 Meter 60dBA @ 1 Meter Noise Level
UPS Unit: 668 x 438 x 133 (3U)
Battery Pack: 580 x 438 x 133 (3U)
UPS Unit: 23
Battery Pack: 63
UPS Unit: 23
Battery Pack: 63 x 2
23 38
Dimension (mm) D x W H
Net Weight (kgs)
Dimension (mm) D W H
Net Weight (kgs)
Standard Model
Long-Run Model
L stands for Long-run model
S stands for Standard model
*All specications, designs and contents are subject to change without prior notice.
23
Online UPS
Master Series (3P/3P) - Tower
Online Master Series
10kVA 30kVA
True Double-Conversion Online UPS
DSP technology guarantees high performance
Input Power Factor Correction 0.99
Active power factor correction in all phases
50/60Hz frequency converter mode
Multiple communication interface (SNMP/USB/RS-232)
Wide input voltage range
Output Power Factor of 0.80
Comes with a maintenance bypass feature
Optional N+X parallel redundancy
Emergency Power Off (EPO) function
Isolation transformer (Optional)
Data
Centre
Electro-Medical
Device
Storage
PLCS
Emergency
Alarm
Devices
E-Business
(Server Farms,
ISP/ASP/POP)
Local Area
Network
(LAN)
Telecommunication
Devices
Master Series (3P/3P) Tower three-phase input / three-phase output, true
online double conversion UPS system guarantees consistent and quality
electrical power to protect your mission critical applications such as small
server room, medical devices, telecommunication facilities and industrial
processes. This (3P/3P) UPS is designed with a wide input voltage range to
handle voltage fluctuating situations and a high accuracy output voltage to
fail-safe your equipment.
The Master Series (3P/3P) UPS system is available in capacities from 10kVA to
30kVA. By adopting the latest IGBT technology, this device is able offer excellent
voltage-switching characteristics during generator operation. An internal
bypass system allowing continuous power is also integrated for convenience
when maintenance is necessary. In addition, this device comes with a parallel
redundant system that allows two UPS models to operate in parallel and as
backup for each other. The Tower series UPS also offers the option of adding on
an isolation transformer to suit your requirements.
Rear Panel
For 10kVA to 30kVA model
1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Share current port (only available for parallel model)
5. Parallel port (only available for parallel model)
6. Intelligent slot
7. Charger fan
8. Power stage fan
9. Maintenance bypass switch
10. Bypass Input Circuit Breaker (Only available for dual input unit)
11. Input circuit breaker
12. Input/Output terminal
13. External battery terminal (only available for Long-run model)
12
10
13
7
7
6
8
8
9
1 2 3 4
11
5
PRO83310S/L
PRO83320S/L
PRO83330S/L
24
Online UPS
AS-400 Card (External Alarm Indicator)
SNMP Card for data communication via network connection
MODBUS Card (Communication interface)
Output Isolation Transformer
Options
Full Specications
50 or 60Hz
300VAC <Vin <480VAC
360/ 380 /400/ 415VAC Nominal Voltage
Voltage Range
Nominal Frequency
Frequency Range
Power Factor
46 ~ 64Hz
0.99
Capacity 10kVA/ 8kW 30kVA/ 24kW
Valve regulated Lead Acid battery (Maintenance free batteries) Type
Capacity
Recharge Time (Typical)
Charging Current
Standard Model
Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3 Regulations
INPUT
MODELS PRO83310S/ L PRO83330S/ L
20kVA/ 16kW
PRO83320S/ L
OUTPUT
BATTERY
MANAGEMENT
ENVIRONMENT
PHYSICAL
OVERLOAD
INDICATORS
EFFICIENCY
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB/ RS-232
1 second >130%
100% < Load < 110%
LCD Display
AC Mode
1%
0.8
Static Regulation
Frequency Range
Frequency
Power Factor
Current Crest Ratio
Voltage Distortion
Linear Load
Non-Linear Load 5% THD
2% THD
Waveform
1.0 A (max) 2.0 A (max) 4.0 A (max)
46 ~ 54Hz or 56 ~ 64Hz
50Hz or 60Hz auto selection or selectable
Pure Sinewave
9AH
9 hours recover to 90% capacity
Up to 89%
3:1
Type
Long-Run Model Capacity
Charging Current 12.0A (max) 4.0 A (max)
10 minutes
110% < Load < 130% 1 minute
Depending on the application
Depending on the application
360/ 380/ 400/ 415VAC Output Voltage
592 x 250 x 576
815 x 250 x 826
815 x 250 x 826
815 x 300 x 1000
<95% non-condensing
0C - +40C
Operation Humidity
IP20 Protection
Ambient Temperature
65dBA @ 1 Meter Noise Level
234 164 109
38 64 40
Dimension (mm) D x W H
Net Weight (kgs)
Dimension (mm) D W H
Net Weight (kgs)
Standard Model
Long-Run Model
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specications, designs and contents are subject to change without prior notice.
25
Online UPS
Power Series
Online Power Series
15kVA 120kVA
Online double conversion technology with DSP control
Harmful effects of harmonic injection are eliminated with the employment
of Adaptive Feed Forward Cancellation (AFC) technology
Very low input current distortion (THDi < 1%)
Input power factor 0.99 at 10% load
Output efciency up to 95%
Control designed to withstand all kinds of loads
Variety of communication options available
Optional N+X parallel redundancy
Remaining backup time calculation
Optional isolation transformer
Data
Centre
Electro-Medical
Device
Storage
PLCS
Emergency
Alarm
Devices
E-Business
(Server Farms,
ISP/ASP/POP)
Local Area
Network
(LAN)
Telecommunication
Devices
Power Series (3P/3P) three-phase input / three-phase output, true online double conversion
UPS system guarantees to supply consistent and quality electrical power to protect your
mission critical applications such as data centres, medical equipments and call centres.
Harmful effects of harmonic injection are eliminated with the employment of Adaptive Feed
Forward Cancellation (AFC) technology. With a UPS system that reflects low harmonic
distortion and high input power factor, it is able to lower installation costs by utilizing smaller
cables and miniature circuit breakers (MCB).
Our team of specialists has gathered together to revolutionize the UPS usability by adding in a
5.7 LCD monitor display with all information and alarm notications viewable within a single
display. To ensure our products are user centered, our group of specialist has also adopted a
front access concept to create a UPS system that is easy for users to carry out preventative
maintenance and replacement activities. In addition, this device comes with a parallel
redundant system that allows four UPS models to operate in parallel. An option of an
additional isolation transformer is also available to suit your requirements. The Power series is
available in models ranging from 15kVA to 120kVA.
Rear Panel (Internal)
For 15kVA to 80kVA model
1. Relay interface
2. Emergency Power Off (EPO)
3. RS-232 COM ports
4. Intelligent Slow
5. Input circuit breaker
6. Maintenance bypass switch
7. Output switch
8. Battery switch
9. System Terminal
10. Parallel port (only available for parallel model)
5
10
7 6
9
1
2
3
8
4
PRO73315S/SI
PRO73320S/SI
PRO73330S/SI
PRO73340S/SI
5
10
7 6
9
1
2
3
8
4
PRO73360S/SI
PRO73380S/SI
5
10
7 6
9
1
2
3
8
4
PRO733100S
PRO733120S
Full Specications
50 or 60Hz
300VAC <Vin <480VAC
360/ 380 /400/ 415VAC Nominal Voltage
Voltage Range
Nominal Frequency
Frequency Range
Power Factor
46 ~ 64Hz
1.0
THDi <1.5%
Capacity 15kVA/ 12KW 60kVA/ 48KW
Depending on the application Type
Capacity
Temperature Compensation
Charging Current
Safety: EN62040-1-1; EMI: EN62040-2; EN61000-1 Regulations
INPUT
MODELS PRO73315S/ SI
20kVA/ 16KW
PRO73320S/ SI
30kVA/ 24KW
PRO73330S/ SI
40kVA/ 32KW
PRO73340S/ SI PRO73360S/ SI
80kVA/ 64KW
PRO73380S/ SI
OUTPUT
BATTERY
MANAGEMENT
ENVIRONMENT
PHYSICAL
OVERLOAD
EFFICIENCY
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB/ RS-232
20 seconds >150%
100% < Load < 125%
AC Mode
1%
5% in 10 ms
0.8
Static Regulation
Dynamic Stability
Frequency Stability
Frequency
Power Factor
Current Crest Ratio
Voltage Distortion
Linear Load
Non-Linear Load 1.5% THD
0.5% THD
Phase
Displacement
Balanced Load
Unbalanced Load 120 2%
120 1%
Waveform
23 A (max) 47 A (max) 70 A (max)
0.05%
50Hz or 60Hz auto selection or selectable
Pure Sinewave
Depending on the application
-18mV/C
Up to 94%
3.2:1
10 minutes
125% < Load < 135%
135% < Load < 150%
5 minutes
1 minute
360/ 380/ 400/ 415VAC Output Voltage
805 x 590 x 1320 700 x 450 x 1100
<95% non-condensing
0C - +40C
Operation Humidity
IP20 Protection
Ambient Temperature
42 ~ 69dBA @ 1 Meter Noise Level
300 180 200 110
Dimension (mm) D x W H
Net Weight (kgs)*
Online UPS
For 100kVA to 120kVA model
1. Relay interface
2. Emergency Power Off (EPO)
3. RS-232 COM ports
4. Intelligent Slow
5. Input circuit breaker
6. Maintenance bypass switch
7. Output switch
8. Battery switch
9. System Terminal
10. Parallel port (only available for parallel model)
5
10
7 6
9
1
2
3
8
4
If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered.
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specications, designs and contents are subject to change without prior notice.
26
Online UPS
SNMP Card for data communication via network connection
MODBUS Card (Communication interface)
Output Isolation Transformer
Options
50 or 60Hz
300VAC <Vin <480VAC
360/ 380 /400/ 415VAC Nominal Voltage
Voltage Range
Nominal Frequency
Frequency Range
Power Factor
46 ~ 64Hz
1.0
THDi <1.5%
Capacity 120kVA/ 96KW
Depending on the application Type
Capacity
Temperature Compensation
Charging Current
Safety: EN62040-1-1; EMI: EN62040-2; EN61000-1 Regulations
INPUT
MODELS
100kVA/ 80KW
PRO733100S PRO733120S
OUTPUT
BATTERY
MANAGEMENT
ENVIRONMENT
PHYSICAL
OVERLOAD
EFFICIENCY
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB/ RS-232
20 seconds >150%
100% < Load < 125%
AC Mode
1%
5% in 10 ms
0.8
Static Regulation
Dynamic Stability
Frequency Stability
Frequency
Power Factor
Current Crest Ratio
Voltage Distortion
Linear Load
Non-Linear Load 1.5% THD
0.5% THD
Phase
Displacement
Balanced Load
Unbalanced Load 120 2%
120 1%
Waveform
70 A (max) 150 A (max)
0.05%
50Hz or 60Hz auto selection or selectable
Pure Sinewave
Depending on the application
-18mV/C
Up to 93%
3.2:1
10 minutes
125% < Load < 135%
135% < Load < 150%
5 minutes
1 minute
360/ 380/ 400/ 415VAC Output Voltage
805 x 590 x 1320
<95% non-condensing
0C - +40C
Operation Humidity
IP20 Protection
Ambient Temperature
69dBA @ 1 Meter Noise Level
255
Dimension (mm) D x W H
Net Weight (kgs)*
If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered.
L stands for Long-run model
S stands for Standard model
I stands for Isolation Transformer (Optional)
*All specications, designs and contents are subject to change without prior notice.
27
Online UPS
The Most Versatile Solution For Power
Protection
The Power Series is designed with the new state of art
transformerless PWM technology that can be easily
adapted to any kinds of complicated loads such as the
non-linear systems (IT systems), highly inductive/
capacitive loads, high-density discharge lamps and
induction motors. The Power series is designed with 2
important criterions in mind; maximum efciency and
energy conservation. The unit also comes with a small
form factor to allow for minimum installation effort.
Furthermore, a parallel redundant system is integrated to
allow two UPS models to operate in parallel as backup
for each other. The Power Series is available in
capacities ranging from 15 to 120kVA.
Online Double Conversion Technology with
DSP Control
The Power Series is able provide a higher load up-time
and effective insulation against network disturbance
with its online double conversion technology. A Digital
Signal Processor (DSP) controller improves the
performance and efciency of the UPS.
Advanced Control with Adaptive Feed Forward
Cancellation (AFC) Technology
By cancelling both the input current and the output
voltage harmonics, the harmful effects of harmonic
injection can be eliminated and this enhances the load
integrity.
Low Input Current Distortion (THDi < 1%)
AFC cells are used to achieve extremely low distortion
values. The Power series is able to obtain a low input
current distortion at THDi < 1% under full load and a THDi
< 5% under smaller load (i.e. 10% of load). This will
prevent distortion of electrical network upstream and
thus, result in the reduction of cable usage and protective
devices in the electrical network.
Input Power Factor 0.99 At 10% Load
Lower power losses would result in reduced
consumption, lower operation and maintenance costs.
Output Efciency of up to 95%
Designed with a DSP controller and fourth generation
IGBT transistors, the UPS is able to achieve extremely
high efciency of up to 95%. With such high ratings,
components in the UPS are not only protected but also
prolonged due to the decrease in heat losses.
Small Form Factor
Utilizes a transformerless technology allows the design
of the UPS to be lighter and smaller.
1,20
1,00
0,80
0,60
0,40
0,20
0,00
0% 25% 50%
LOAD
INPUT POWER FACTOR
P
F
i
n
100%
75%
50%
25%
0%
0%
SERIES TIPICAL EFFICIENCY
25% 50%
E
F
F
I
C
I
E
N
C
Y
LOAD
28
Online UPS
Front Access concept
An important consideration
has been given during the
UPS design phase to create a
system that allows users to
access the units electronic
cards and power
components with minimum
effort. All electronic boards
and components can be
accessed from the front
panel for easy maintenance
and replacement activities.
Versatile Single-Phase / Three-Phase set-ups
This highly versatile UPS is designed with different types
of setting-up options;
Three-phase input / Three-phase output (III/III)
Three-phase input / Single phase output (III/I)
Control Components are designed to
with stand all kinds of loads
In the Power Series, the control components are
designed to withstand all types of loads. These include
loads such as; resistive, capacitive, non-linear,
high-density discharge lamps, induction motors, speed
drives etc. This makes the UPS extremely compatible
with many types of electronics. Better yet, the UPS
comes with a wide array of parameters that can be
programmed locally or remotely to t different types of
environment.
N+1 Redundancy
A parallel redundant system allows 4 UPS models to
operate in parallel and as backup for each other.
Variety Of Communications And Option
Available
The UPS has provided the following standard
communication selections:
Relay interface
RS-232/485 port
1 SNMP slot
Modbus RTU / SEC protocol
2 connectors for parallel connection
Made of 60% Recyclable
Materials
When it comes to conserving the
environment, PROLiNK is committed to
play a part by designing their UPS
products using recyclable materials.
Back-up Time indicator
With the use of simple algorithms, an estimated
remaining back-up time can be calculated and
indications will be reflected on a LCD panel.
5.7 Multiple Languages Graphical LCD
Display
Our team of specialists has gathered together to
revolutionize the UPS usability by adding in a 5.7 LCD
monitor display with all information and alarm
notications viewable within a single display.
29
30
Online UPS
PPM Series
PROLiNK Power
Modular (PPM)
UPS System
N+1 parallel redundancy
Online double conversion technology
Output Power Factor of 1
Modular design decreases MTTR
High scalability
Internal maintenance bypass available
Adjustable charging current
Highly interactive 5.7" LCD design
PROLiNK PPM Series modular three-phase input / three-phase output
online double conversion UPS takes scalability to a whole new level. Based
on a scalable design, the PPM comes with a wide range of capacity, ranging
from as low as 30kVA to as high as 210kVA. The PPM series is designed with
a N+X parallel redundancy system that allows two or more UPS modules to
operate in parallel and as back-up for each other. This unit provides an ideal
protection for data centers, telecommunication facilities and other critical
applications. Up to seven 30kVA modules can be tted into a standard
cabinet to simplify maintenance and replacement activities. The PPM Series
guarantees a low mean-time-to-repair (MTTR), giving users a shorter
elapsed time between the point of repair and the point of equipment
recovery.
High Efciency Online Double Conversion
Technology
PROLiNK PPM is designed with the latest online double
conversion technology that provides a high efciency
rating of 96%. With such a high efciency rating, the PPM
can save you hundreds of dollars each year.
High Scalability
Based on a scalable design, the PPM Series simplies
future expansion by making UPS units easily upgradable.
This architecture allows you to meet power demands by
adding additional modules vertically in a single rack
enclosure.
Unity Output Power Factor
With a unity output factor (kVA = kW), the PROLiNK PPM
UPS system is 100% compatible with today's high power
factor loads. It is able to meet the latest server
requirements, giving the best value for your IT
investments.
Modular Design Lowers MTTR
The modular design ensures uninterrupted power supply
during UPS maintaining and replacing activities. Also, the
PPM Series guarantees a low mean-time-to-repair
(MTTR), giving users a shorter elapsed time between the
point of repair and the point of equipment recovery.
Data
Centre
Electro-Medical
Device
Storage
PLCS
Emergency
Alarm
Devices
E-Business
(Server Farms,
ISP/ASP/POP)
Local Area
Network
(LAN)
Telecommunication
Devices
31
Online UPS
N+X Parallel Redundancy
The PPM series is designed with a N+X parallel
redundancy system that allows two or more UPS
modules to operate in parallel and as back-up for each
other.
Ease Of Installation and Maintenance
With a built-in maintenance bypass feature, the UPS is
able to deliver continuous power to the critical load
during maintenance. Better yet, the PPS comes with a
front access concept to facilitate installation.
Adjustable Charging Current
PROLiNK PPM comes with a maximum charging current
of up to 8A for each individual module. The charging
current can be adjusted based on the necessary
requirement.
High Overload Capability
PROLiNK PPM supports 110% overload for 60 minutes,
120% for 10 minutes and 150% for 1 minute.
5.7 LCD Graphic Mimic Panel
A multilingual 5.7" graphic
LCD screen is integrated as
part of the design to provide
users with visual information
and advanced control
abilities.
The PROLiNK PPM90 is a compact stand alone UPS system that provides the
best backup solution for small and medium loads. This unit comes with a
standard EIA height of 30U and is able to t capacities ranging from 30kVA to
90kVA in the same cabinet. With features such as N+1 redundancy and the
capability for future expansion, the PROLiNK PPM90 is denitely able to make
your backup experience an absolute cinch.
PPM90
No. Of Module
1
2
3
Capacity
60kVA
90kVA
Dimension
600 x 1100 x 1485 (30U) mm
30kVA
Exterior Interior
The PROLiNK PPM210 is a standalone UPS system that comes with a standard
EIA height of 42U. This unit is able to t 7 x 30kVA modular redundancy in the
same cabinet. Even better, the PPM210 has the capability to manage future
capacity expansion of up to 210kVA, making the PPM210 the best backup
solution for greater loads.
PPM210
No. Of Module
1
2
3
4
5
6
7
Capacity
60kVA
90kVA
120kVA
150kVA
180kVA
210kVA
Dimension
600 x 1100 x 2030 (42U) mm
30kVA
Exterior Interior
32
Full Specications
50/60Hz (auto-selectable)
40Hz ~70Hz
> 0.99
< 3%
305 ~ 477 Vac @Full load, 208 ~ 477 Vac @ <70% load
3 x 400 VAC (3Ph+N) Nominal Voltage
Voltage Range
Nominal Frequency
Frequency Range
Power Factor
Harmonic Distortion (THDi)
PHASE
TOPOLOGY
+/- 240V (12V x 20 Pcs) Nominal Voltage
Float Charging Voltage
Boost Charging Voltage
Temperature Compensation
Apparent Power (watt)*
Max. Battery Charging Current
Operation Temperature
Relative Humidity
Altitude
IP Class
RS-232/USB
Optional SNMP
Supports Windows 2000/2003/XP/Vista/2008/7, Linux, Unix and MAC
Power management from SNMP manager and web browser
INPUT
MODELS
3-phase in/3-phase out
True Double-Conversion Online
PPM
OUTPUT
BATTERY
MODULE
STANDARDS
ENVIRONMENT
MANAGEMENT
50/60Hz
46Hz ~ 54Hz or 56Hz ~ 64Hz (Synchronized)
1 hour for 110%,
10 mins for 120%,
1 min for 150%,
200ms for >150%
1% THD (Linear Load);
4% THD (Non-linear Load)
> 96%
Voltage Regulation (Transient)
Voltage Regulation (Steady state)
Nominal Frequency
Frequency Range
Overload Capability
Harmonic Distortion
Efciency
5% Typical
1% Typical (balanced load); 2% Typical (unbalanced load)
Active Power (VA) 30kVA
30kWatt
8A (Adjustable)
2.25V/Cell
2.35V/Cell
Yes
0 ~ 40C
0 ~ 95% non-condensing
<1000m for Nominal power
IP 20
3 x 400 VAC (3Ph+N) Nominal Voltage
IEC/EN 60950-1; IEC/EN 62040-1
IEC/EN 62040-2 Category C34.9
Safety
EMC
When temperature above 30C, the system output power factory will become 0.8
One power module provides 30kW power capacity. One battery module contains 10 pcs of 12V7Ah, 12V9Ah or 12V10Ah (subject to requirement) Valve Regulated Lead Acid batteries.
All specications, designs and contents are subjected to changes without prior notice.
Online UPS
33
Line Interactive UPS
PRO SFC Series
Super Fast Charging
Line Interactive Series
650VA - 1200VA
Built-in super fast charger, battery can be recharged to 90% of
its capacity within 2-4 hours
Excellent microprocessor control guarantees high reliability
Boost and buck AVR for voltage stabilization
Auto restart while AC is recovering
Simulated sine wave
Off-mode charging
Cold start function
Optional USB/RS-232 communication port and RJ-11/RJ-45 protection
PROLiNK SFC series is a single-phase input/ single-phase output
Line-Interactive UPS system with PROLiNKs latest Super-Fast
Charging technology. This cutting-edge technology is able to
recharge the battery back to 90% of its capacity within 2-4 hours,
and is ideal for providing stable backup power to home/ small
ofce applications. A wide input voltage range is supported due to
the integrated 3-Step AVR which features 2 boosts and 1 buck to
regulate output voltage. This prevents under voltage brownouts
and over voltage surges. The unit also comes with universal
sockets to provide better compatibility with a wider range of
devices.
Rear Panel
For 650VA to 1200VA model
1. AC Input
2. Backup Output
3. Bypass Output (without battery back up)
4. USB Port (Only available in SFCU series)
5. RJ11
PC Printer Work-Stations
PRO1200SFC/ SFCU
5
1 2
2 3
4
PRO700SFC/ SFCU PRO850SFCU
1
2
2
4
5
1
2
2
4
34
Line Interactive UPS
Full Specications
50 or 60Hz (Auto Sensing)
25%
220/ 230/ 240VAC Nominal Voltage
Voltage Range
Nominal Frequency
Capacity
650 VA
Watt
1200
1 x 12V8.2AH 1 x 12V10AH 2 x 12V8.2AH Number of Battery
Recharge Time (Typical)
Battery Mode Sounding every 10 seconds
Low Battery Sounding every second
Overload Sounding every 0.5 seconds
Battery Replacement Alarm Sounding every 2 seconds
Fault Continuously Sounding
INPUT
MODELS PRO700SFC/ SFCU
850
360 600 480
PRO850SFCU PRO1200SSFC/ SFCU
OUTPUT
BATTERY
PROTECTION
MANAGEMENT
ENVIRONMENT
PHYSICAL
INDICATION
ALARM
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB/ RS-232
LED Display
Sounding
Simulated Sinewave
Transfer Time (Typical)
Frequency
Waveform
2 - 8ms 2 - 6ms, 10ms (max)
50Hz or 60Hz 1Hz
Full Protection Short Circuit, Overload, Discharge and Overcharge Protection
2 4 hours recover to 90% capacity
AC Mode Green Lighting
Battery Mode Yellow Lighting
Charging Mode Green Flashing every 2 seconds
Overload Red Flashing every 0.5 seconds
Fault Red Lighting
10% Output Voltage Regulation (Battery Mode)
350 x 146 x 160 287 x 100 x 142
Less than 40dBA Noise Level
0-90% relative Humidity, 0C - +40C Humidity
8 4.25 4.9
Dimension (mm) D x W H
Net Weight (kgs)
*All specications, designs and contents are subject to change without prior notice.
35
Line Interactive UPS
PRO Series
Line Interactive Series
650VA 1200VA
Built-in super smart charger, shorten 50% of charging time
Excellent microprocessor control guarantees high reliability
Boost and buck AVR for voltage stabilization
Auto restart while AC is recovering
Simulated sine wave
Off-mode charging
Cold start function
Optional USB/RS-232 communication port and RJ-11/RJ-45 protection
Offering LED and LCD panels for selections
PRO Series is a single-phase input / single-phase output
line-interactive UPS system. It is able to provide clean
electrical power and is ideal for home / small ofce
applications. A wide input voltage range is supported due to
the integrated 3-Step AVR which features 2 boosts and 1
buck to regulate output voltage. This prevents under voltage
brownouts and over voltage surges. The unit also comes
with universal sockets to provide better compatibility with a
wider range of devices.
Rear Panel
For 650VA to 1200VA model
1. AC Input
2. Backup Output
3. Bypass Output (without battery back up)
4. USB Port (Only available in VU and SVU series)
5. RJ11
PC Printer Work-Stations
PRO700V/ VU PRO850VU PRO850SU PRO1200SV/ SVU
1
2
2
4
5
1 2
2 3
4
1
2
2
3
5
1
2
2
4
36
Line Interactive UPS
Full Specications
50 or 60Hz (Auto Sensing)
25%
220/ 230/ 240VAC Nominal Voltage
Voltage Range
Nominal Frequency
Capacity
650 VA
Watt
1200
1 x 12V8.2AH 1 x 12V10AH 2 x 12V8.2AH Number of Battery
Recharge Time (Typical)
Battery Mode Sounding every 10 seconds
Low Battery Sounding every second
Overload Sounding every 0.5 seconds
Battery Replacement Alarm Sounding every 2 seconds
Fault Continuously Sounding
INPUT
MODELS PRO700V/ VU
850
360 600 480
PRO850VU/ SU PRO1200SV/ SVU
OUTPUT
BATTERY
PROTECTION
MANAGEMENT
ENVIRONMENT
PHYSICAL
INDICATION
ALARM
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB/ RS-232
LED Display
Sounding
Simulated Sinewave
Transfer Time (Typical)
Frequency
Waveform
2 - 8ms 2 - 6ms, 10ms (max)
50Hz or 60Hz 1Hz
Full Protection Short Circuit, Overload, Discharge and Overcharge Protection
4 - 6 hours recover to 90% capacity
AC Mode Green Lighting
Battery Mode Yellow Lighting
Charging Mode Green Flashing every 2 seconds
Overload Red Flashing every 0.5 seconds
Fault Red Lighting
10% Output Voltage Regulation (Battery Mode)
350 x 146 x 160 287 x 100 x 142
Less than 40dBA Noise Level
0-90% relative Humidity, 0C - +40C Humidity
8 4.25 4.9
Dimension (mm) D x W H
Net Weight (kgs)
*All specications, designs and contents are subject to change without prior notice.
37
PRO-L Series
Line Interactive Series
600VA 2000VA
Excellent microprocessor control guarantees high reliability
Boost and buck AVR for voltage stabilization
Adjustable battery charging current
Auto restart which AC is recovering
Off-mode charging
Cold start charging
Simulated sine wave
PRO-L Series is a single-phase input / single-phase output
line-interactive UPS system that provides clean and reliable
back-up power for longer periods of time. It is able to provide
clean electrical power and is ideal for home / small ofce
applications. A wide input voltage range is supported due to
the integrated 3-Step AVR which features 2 boosts and 1
buck to regulate output voltage. High voltage battery
chargers and battery extension assembly are made
available for longer runtime applications. The PRO-L Series
with capacities of up to 850VA also comes with universal
sockets to provide better compatibility with a wider range of
devices.
Rear Panel
For 600VA to 2000VA model
1. AC input
2. Input protection
3. Output outlet
4. Battery Connection
5. Fan
PC Printer Work-Stations
Line Interactive UPS
PRO1000L/
PRO2000L
PRO700L
5
1
2
3
4
5
1
2
3 3
4
38
Line Interactive UPS
Battery Pack
For 600VA to 2000VA model
Model
Battery Type
Battery Number
Dimension (DxWxH) mm
G6
6 pcs
397 145 220
12 pcs
G12 G18 G60
18 pcs 60 pcs
421 190 318 535 190 318
12V7AH/ 12V9AH/ 12V10AH
830 x 250 x 576
Full Specications
50 or 60Hz (Auto Sensing)
25%
220/ 230/ 240VAC Nominal Voltage
Voltage Range
Nominal Frequency
Capacity
600 VA
Watt
2000
12VDC 24VDC Battery Voltage
Battery Capacity
Charging Current (max.)
Battery Mode Sounding every 10 seconds
Low Battery Sounding every second
Overload Sounding every 0.5 seconds
Battery Replacement Alarm Sounding every 2 seconds
Fault Continuously Sounding
INPUT
MODELS PRO700L
1000
360 1200 600
PRO1000L PRO2000L
OUTPUT
BATTERY
Dimension (mm) D x W H
PROTECTION
ENVIRONMENT
PHYSICAL
INDICATION
ALARM
LED Display
Sounding
Simulated Sinewave
Transfer Time (Typical)
Frequency
Waveform
50Hz or 60Hz 1Hz
Typical 2-6ms, 10ms max.
Full Protection Short Circuit, Overload, Discharge and Overcharge Protection
Depending on the application
AC Mode Green Lighting
Battery Mode Yellow Lighting
Charging Mode Green Flashing every 2 seconds
Overload Red Flashing every 0.5 seconds
Fault Red Lighting
10% Output Voltage Regulation (Battery Mode)
395 x 145 x 220 358.5 x 96.8 x 146.5
5A/ 10A/ 15A/ 20A (adjustable) 2.5A/ 6A/ 10A (adjustable)
Less than 40dBA Noise Level
0-90% relative Humidity, 0C - +40C Humidity
9.5 5.8 9.0 Net Weight (kgs)
*All specications, designs and contents are subject to change without prior notice.
39
PRO Rack/ Tower Series
Line Interactive Series 800VA 3000VA
Microprocessor-based line interactive design
Pure sine wave output online mode and battery mode
User-friendly and easy-shift LCD display
Rack/Tower design
Built-in boost and buck AVR
Output power factor 0.8
Hot-swappable battery design
Programmable power management outlets
Emergency Power Off Function (EPO)
Long-run models available
Multiple communication available
Option for SNMP communication.
PRO Rack / Tower series is a single-phase input / single-phase output UPS that employs a line-interactive technology.
This device comes with a practical 2U universal-mount case that provides an option for the user to either install it as a
floor-standing tower or in a mounting position using a 19-inch rack mount bracket. With its high density output power
factor of 0.8, this device is able to provide outstanding performance and efciency for any home / small ofce applica-
tions. A wide input voltage range is supported due to the integrated 3-Step AVR which features 2 boosts and 1 buck to
regulate output voltage.
Rear Panel
For 800VA to 3000VA model
1. Programmable outlets: Connect to non-critical loads
2. Output receptacles: Connect to mission-critical loads
3. AC input
4. Input circuit breaker
5. Network/Fax/Modem surge protection
6. Emergency power off function connector (EPO)
7. USB communication port
8. RS-232 communication port
9. SNMP intelligent slot
10. Battery Compartment (only available for Standard model)
11. Output terminal (IEC320-14)
12. Fan
13. External battery pack numbers detection port
Line Interactive UPS
PC Printer Work-Stations 19 Rack
Mount
PRT800S
PRT1100S/ PRT1100L/ PRT2000S/ PRT2000L
PRT3000S/ PRT3000L
5
1
6
7
8
9 12
13
2
3 4
5
1
6
7
8
9 12
10
13
2
3 4
5
1
6
7
8
9 12 12
10
13
2
11
3
4
40
Line Interactive UPS
Battery Pack
For 1.1kVA to 3kVA model
Model
Battery Type
Battery Number
Dimension (DxWxH) mm
G8R G12R G20R
480 x 438 x 88
8 pcs 12 pcs 20 pcs
12V7AH/ 12V9AH/ 12V10AH
580 x 438 x 133 600 x 438 x 88
Full Specications
50 or 60Hz
162 ~ 290VAC
208/ 220/ 230/ 240VAC Nominal Voltage
Voltage Range
Nominal Frequency
Capacity 800 VA/ 640 W 3000 VA/ 2400 W
15% THD
8% THD
Waveform
4.0 A (max.)
Depending on the application
Depending on the application
Charging Current
Capacity
Type
AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery
380 x 438 x 88
INPUT
MODELS PRT800S
1100 VA/ 880 W
PRT1100S/ L PRT3000S/ L
2000 VA/ 1600 W
PRT2000S/ L
OUTPUT
Voltage Distortion
Liner Load
Non-Liner Load
EFFICIENCY
MANAGEMENT
ENVIRONMENT
PHYSICAL
INDICATORS
BATTERY
Long-Run Model
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB/ RS-232
Standard Model
LCD Display
3:1
Power Factor
Frequency
Current Crest Ratio
0.8
50Hz or 60Hz 1Hz
AC Mode Up to 97%
Pure Sinewave
Value regulated Lead Acid battery (Maintenance free batteries)
4 hours recover to 90% capacity
1.0 A (max.)
Type
Capacity
Recharge Time (Typical)
Charging Current
3% Static Regulation (Battery Mode)
600 x 438 x 88 380 x 438 x 88
45dBA @ 1 Meter
0C - +40C
Noise Level
Ambient Temperature
0-90% non-condensing Operation Humidity
18
480 x 438 x 88
14
N/A
10.8
Long-Run Model
Dimension (mm) D x W H
Standard Model
Dimension (mm) D W H
Net Weight (kgs)
Net Weight (kgs) 12.9 14.23
480 x 438 x 88
23.11
600 x 438 x 88
32.24
7AH 9AH
*All specications, designs and contents are subject to change without prior notice.
41
Inverter UPS
IPS Series
LCD Inverter Series
Simulated sine wave inverter
10 A or 20 A charging current
Auto restart while AC is recovering
Overload and short circuit protection
Generators & Computer-related devices compatible
LCD and LED indicators
Cold start function
PROLiNK IPS LCD Series is a compact inverter system that delivers high efciency conversion from DC to AC power. This
economically ideal system provides clean and stable power for home appliances and electronic devices. With a built-in
20Amp DC charger current, this unit is able to charge a VRLA battery of up to 200Ah. In addition, the PROLiNK IPS LCD
series comes with a universal socket outlet that provides the versatility to be utilized in various situations.
Rear Panel
For 1200VA to 5000VA model
1. Battery Connector
2. Input Protector
3. AC Input
4. Inverter Output
5. Narrow/ Wide Selector (only available for
IPS1200 and IPS2400)
6. 10Amp/20Amp Charging Current Selector
(only available for IPS1200 and IPS2400)
IPS1200/ IP2400
5
6
1
2
3
IPS3000 IPS5000
1
2
3 4
1
2
3 4
4
42
Full Specications
*All specications, designs and contents are subject to change without prior notice.
Inverter UPS
170 - 280VAC 162 - 290VAC
90 - 280VAC
220/ 230/ 240VAC Nominal Voltage
Voltage Range
Narrow Range
Wide Range
VA
Watt
Capacity
5000
10Amp / 20Amp (selectable) 20Amp Charging Current
DC Voltage
INPUT
MODELS
1200
IPS1200
2400
IPS2400
3000
4200 720 1440 2500
IPS3000 IPS5000
OUTPUT
BATTERY
ENVIRONMENT
PHYSICAL
EFFICIENCY
Alarm
Sounding
INDICATION
LED Display
LCD Display
10%
50Hz or 60Hz
Output Voltage Regulation (Battery Mode)
Frequency
1Hz Frequency Regulation (Battery Mode)
Waveform
Transfer Time
Simulated Sinewave Pure Sine Wave
10ms Typical, 20ms (max)
24V 48V 12V
Overcharge Protec 30V 60V 15V
AC Mode - Green
Battery Mode - Yellow
Low Battery Yellow flashing
Shutdown Mode Yellow flashing
Charging Mode - Green flashing
Charging Mode - Green flashing
Overload - Red flashing
AC Mode, Inverter Mode,
Charger Mode, Load Level, Fault
Input Voltage, Output Voltage,
Load level, Battery level, Fault alarm
Overload - Sounding every 0.5 seconds
Low Battery - Sounding every 2 seconds
Overcharging Fault Continuously sounding
AC to AC >95%
DC to AC >80%
Overload - Sounding every 0.5 seconds
Low Battery - Sounding every 2 seconds
High DC Voltage - Continuously sounding
Fan fault Sounding 2 time every 2 second
N/A
230VAC Nominal Voltage
407 x 350 x 110 268 x 330 x 76 293 x 231.5 x 82.5
0~90% Relative Humidity. 0~40C
Less than 50dBA Less than 60dBA
Humidity
Noise Level
9.0 2.55 4.9 2.35
Dimension (mm) D x W H
Net Weight (kgs)
43
Full Specications
PROLiNK PVR
PVR Series
Microprocessor control
Accepts wide input voltage range
Time delay function eliminates transient that can effect
connected equipment
Provides stable output voltage
Provides under-voltage, over-voltage, over-heat and over
current protection
High voltage cut off
PROLiNK PVR Series is designed to automatically maintain a
constant voltage level to protect sensitive electronics from
brownouts, under voltages and over voltages. The PROLiNK PVR
takes efciency to a new level with its microprocessor controller
tailored to allow extremely fast response for detecting and
regulating voltage. Equipped with a time-delay function, the PVR
is able to protect connected devices from power-back surges.
This high performance AVR comes with the versatility to t all
kinds of equipment with its wide input voltage range selection.
The PROLiNK PVR provides you with the optimum solution for
your everyday needs.
Auto Voltage Regulator
110VAC ~ 270VAC or 140VAC ~ 260VAC (selectable)
50 or 60 Hz (Auto Sensing)
Norminal Voltage
Voltage Range
Nominal Frequency
Capacity VA
INPUT
MODELS
500
PVR500 D/M
1000
PVR1000 D/M
2000
92%
PVR2000 D/M
3000
PVR3000 D/M
220 VAC
OUTPUT
Humidity
ENVIRONMENT
PHYSICAL
INDICATION
Operating Temperature
LCD/Meter Display
Dimension, D X W X H (mm)
Net Weight (kgs)
220 VAC
10%
2.4 6.55 8.56 3.91
95%
Voltage
Output Voltage Regulation
Normal Mode
AVR Mode
10 seconds
Short Circuit, Overload and Overvoltage Protection.
Normal indicator, AVR indicator, delay time setting and Fault indicator
Input and Output voltage
196.8 x 110 x 123.5 233.6 x 134 x 181 297.1 x 150 x 199
0C - +40C
0-90% relative Humidity (Non-condensing)
Delay Time
Full Protection
PROTECTION
EFFICIENCY
LED Display
D = LCD display, M = Analogue display
*All specications, designs and contents are subject to change without prior notice.
44
DC UPS
Full Specications
160 - 280VAC
50 or 60Hz
220VAC Nominal Voltage
Voltage Range
Frenquency
Capacity
12V9AH x 1 Battery Type
Charging Voltage
Charging Current
Typical Recharge Time
INPUT
MODELS
50W
PDC50
OUTPUT
BATTERY
AC Mode
Battery Mode
EFFICIENCY
ENVIRONMENT
PHYSICAL
PROTECTION
Battery Mode
Low Battery
Fault
INDICATION
AC Mode
10V ~ 13.7V
0ms
>75% at Nominal Voltage (Battery Fully Charged)
>95% at Full Load
Output Voltage Regulation
Transfer Time
13.7V 0.25V
2.8A or 2.3A at Nominal Voltage without Load
4 ~ 6 hours recover to 90% capacity
Green Lighting
Yellow Lighting
Red Lighting
Yellow Flashing
Full Protection Short Circuit and Overload Protection
12VDC Nominal Voltage
228 x 82.5 x 207
0 ~ 90%
0C ~ 40C
Humidity
Temperature
3
Dimension (mm) D x W H @ Vertically Stand
Net Weight (kgs)
PROLiNK DC UPS
PDC Series - DC UPS
Dual DC Outputs
Microprocessor control guarantees high reliability
Compact size for standing and mounting flexibility
Supports solar powered devices and communication applications
Auto restart while AC is recovering
Off-mode charging
Overload protection and short circuit protection
PROLiNK PDC series is a compact DC UPS system that
converts AC to DC power. This device comes with a built-in
dynamic voltage regulator that ensures the voltage from
the power source is kept within acceptable limits. The PDC
Series is ideal for devices such as switches, hubs, routers
and modems. With the built-in DC start function, the PDC
UPS can be started up with the absence of AC power. The
PROLiNK PDC series is denitely your number one choice
for back-up power solution.
45
Full Specications
PROLiNK DC BACK-UP UNIT
PBU Series
40W DC UPS
DC-powered outlets for 11watts energy saving bulb
3 sets DC-powered outlets for energy saving light bulbs
Off mode charging
Overload protection in battery mode and short circuit protection
LED indication
3-step charging design for extended battery life
PROLiNK Back-Up (PBU) unit is a user-friendly lighting power supply
unit that is suitable for home/ outdoor settings. This portable-sized unit
is compact in size but it comes with a powerful 230VDC output that can
be used for powering up energy saving light bulbs of up to 11W. The unit
is designed with the flexibility to be powered by regular AC supply or via
the supplied battery. The PROLiNK PBU units potential is best realized
for users that commonly experience power blackouts.
The unit is also brilliantly designed to allow a range of flexible display
methods: vertically or horizontally standing, wall-mounted or as a
portable display; as well as a choice to select between a B22 or E27 light
bulb terminal. The PROLiNK Back-Up unit is the perfect cost-effective
solution for your lighting requirements.
DC UPS
100VAC 300VAC
Voltage
Voltage Range
Rated Power
INPUT
MODELS
50VA/40W
PBU5022 / PBU5027
4 hours recover to 90% capacity
230 VAC
OUTPUT
Humidity
OPERATING ENVIRONMENT
PHYSICAL
PROTECTION
Operating Temperature
Dimension, D X W X H (mm)
Net Weight (kgs)
230 VDC
160-230 VDC 10%
DC Output
0.67
230 VAC
12V7Ah x 1
12 VDC
2-pin Sockets
Battery Type and Number
Battery Voltage
Output Voltage (Batt. Mode)
Waveform
Output Voltage (AC Mode)
Typical Recharge Time
Battery Mode Yellow Lighting
AC Mode Green Lighting
Output Short-circuited Red Lighting
Charging Mode Green Flashing every 3 seconds
Low Battery Yellow Flashing every 2 seconds
Overload Red Flashing every 0.5 seconds
Overcharge Red Flashing every 5 seconds
Battery weak at start-up Red and Yellow Flashing 3 times and then shut down
Overload Protection and short circuit protection
228 x 82.5 x 207
0C to 40C
0-90% relative Humidity (Non-condensing)
LED Display
INDICATORS
BATTERY & CHARGER
Full Protection
Backup Time Table:
PBU5022 = for B22 light bulb terminal.
PBU5027 = for E27 light bulb terminal.
*All specications, designs and contents are subject to change without prior notice.
11W Safe Energy Light Bulb x 1 no
11W Safe energy light bulb x 2 nos
11W Safe energy light bulb x 3 nos
11W Safe energy light bulb x 4 nos
Up to 6 hours
Up to 2 hours
Up to 3 hours
Up to 1.5 hours
B22 Connector E27 Connector
46
All specications, designs and contents are subjected to changes without prior notice.
The above Battery back-up calculation is based on estimated values and will be subject to change (Variables include; load consumption, sunshine duration and PV panel peak power supply).
Solar
PROLiNK Solar Inverter
Zonne Series
450W Inverter
PWM technology solar charger
Off mode charging
Overload protection and short circuit protection in battery mode
Universal socket
PROLiNK Zonne 450 unit is a compact and
user-friendly solar power unit that is suitable for use
in home like settings. The Zonne series is designed
with a built-in charger controller that facilitates
proper charging of the battery, enhancing the overall
lifespan of the battery.
Also, the PROLiNK Portable Solar unit comes with the
flexibility to be powered by regular AC supply, solar
PV modules or via the supplied battery. The Zonne
unit is capable of supporting up to one block of
100AH battery, giving users ample amount of power
supply to operate multiple home appliances.



External Battery
Solar Panel
Utility Supply
Home Appliance
Backup Time Table:
Battery Type Effective Sunshine Duration Application / Load Battery back-up
1 block x 12V40AH 5 hours
2 x energy saving light bulb 8 hours per day
1 x energy saving light bulb
1 x Fan
6 hours per day
2 x energy saving light bulb
1x Fan
4 hours per day
Battery Type Effective Sunshine Duration Application / Load Battery back-up
1 block x 12V65AH 5 hours
2 x energy saving light bulb 10 hours per day
1 x energy saving light bulb
1 x Fan
8 hours per day
2 x energy saving light bulb
1x Fan
6 hours per day
47
*All specications, designs and contents are subjected to changes without prior notice.
*Above mentioned Back-up timetable is for reference purpose only.
Solar
Full Specications
90 or 280 VAC (INV. Mode)
162-290 VAC (UPS Mode)
220/ 230/ 240VAC
450W
Zonne 450
Voltage
Voltage Range
Rated Power
12 VDC
10Amp
Battery Voltage
Floating Voltage
Maximum Charge Current
AC INPUT
MODELS
OUTPUT
BATTERY & CHARGER
PROTECTION
PHYSICAL
INDICATORS
Line Mode
Battery Mode
Low Battery
Shutdown Mode
Charging Mode at Power On
Charging Mode at Power Off
Overload
Overcharging
Fault
Simulated Sinewave
Voltage Regulation (Batt.Mode)
Waveform
Full Protection Overload and Short Circuit Protection
13.4VDC 1.5%
Green Lighting
Yellow Lighting
Yellow Flashing every 2 seconds
Yellow Flashing every 5 seconds
Green Flashing every 2 seconds
Green Flashing every 5 seconds
Red Flashing for 0.5sec. every seconds
Red Flashing every 5 seconds
Red lighting
230VAC
10%
Output Voltage
293 x 231.5 x 82.5
2.35
Dimension (mm) D x W H
Net Weight (kgs)
SOLAR CHARGER
10Amp
12VDC
Charging Current
System Voltage
48
Full Specications
PROLiNK PORTABLE SOLAR
PPS Series
70W DC UPS
DC-powered outlets for 11watts energy
saving bulb
3 x 5V USB charger ports for mobile phones
PWM technology solar charger
Off mode charging
Overload protection and short circuit protection in
battery mode
12VDC round pin connector output for 12VDC
equipment
Option for lamp holder with 2m cable
Option for 24W Solar PV panel
PROLiNK Portable Solar (PPS) unit is a compact and user-friendly lighting
solar power supply unit that is suitable for use in home / outdoor settings.
This portable-sized unit is compact in size but it comes with a powerful
230VDC output that can be used for powering up energy saving light bulbs
of up to 11W. In addition, there is also a 5VDC USB port for charging your
mobile devices and a 12VDC round pin connector for equipment such as DC
fans. The unit is designed with the flexibility to be powered by regular AC
supply, solar PC modules or via the supplied battery.
PROLiNK Portable Solar unit provides you the option of doubling up your
backup duration by adding another block of 7AH battery on top of the
existing supplied battery. The PPS is the perfect device for users living in
rural locations where the power supply is often inconsistent and unstable.
Solar
2 A
Maximum PV Array Open Circuit Voltage
Maximum Solar Charging Current
Capacity
PV INPUT
MODELS
70W
PPS70
12VDC 2A x 1 pc
5VDC 1A x 3 pcs
30 VDC
AC INPUT
Humidity
OPERATING ENVIRONMENT
PHYSICAL
PROTECTION
Operating Temperature
Dimension, D X W X H (mm)
Net Weight (kgs)
230 VAC
50 Hz or 60 Hz (auto sensing)
3.8
230 VDC
160-230 VDC 10%
DC Output
Voltage
Frequency Range
2-pin Sockets Output Voltage (Batt. Mode)
Waveform
Output Voltage (AC Mode)
DC Connector
USB Charger
12V7Ah x 1 (Optional external battery)
12 VDC
4 hours recover to 90% capacity
Overload Protection and short circuit protection
229 x 110 x 123.5
0C to 40C
0-90% relative Humidity (Non-condensing)
Battery Type and Number
Battery Voltage
Typical Recharge Time
BATTERY & CHARGER
OUTPUT
Full Protection
*All specications, designs and contents are subject to change without prior notice.
Solar
Mobile Phone
Utility Supply
12VDC Supply
3 Outlet For Energy Saving Bulb
External Battery
49
Full Specications
PROLiNK Solar System
PCC Series
Intelligent Maximum Power Point Tracking technology
Built-in DSP controller with high performance
Automatic battery voltage detection
Multi-functional LCD
Reverse polarity protection for solar panel and battery
Overcharge and overload protection
Suitable for battery types such as sealed lead acid, vented Gel and NiCd
Standard RJ45 port or optional RS-485 communication port for remote monitoring

*All specications, designs and contents are subject to change without prior notice.
PCC Series is a Solar Installation System that combines the benets of both the
Maximum Power Point Tracking (MPPT) technology and DSP controller system.
The MPPT enhances the PCC Series by transferring the most power from its PV
solar modules and the DSP controller system provides a high level of
computational performance for real-time signal processing in the solar power
inverters. This allows your solar panels to operate at their optimum power output
voltage, thereby increasing the level of efciency to 97.7% and at the same time
lowering power loss.
Users can start generating green energy for their home applications by integrating
the PCC Series with solar panels, inverter and external battery packs. Batteries are
compatible with up to 4 types; sealed lead acid, vented, gel and NiCad.
Solar
75V 150VDC 50V
18A 45A
30 ~ 66V @ 24V 60 ~ 132VDC 15 ~ 33V @ 12V MPPT Range @ Operating Voltage
Maximum PV Array Open Circuit Voltage
Maximum Current
Capacity
>110%: Audiable Alarm Yes Overload Protection
Overcharge Protection
Polarity Reversal Protection @ Solar Cell & Battery
INPUT
MODELS
600W
PCC600
3000W
PCC3000
300W
PCC300
OUTPUT
PROTECTIONS
ENVIRONMENT
PHYSICAL
INDICATION
LCD Panel
LED Display
Sealed Lead Acid, Vented, Gel, MiCd Battery
<1V
Three Stages: Bulk, Absorption & Floating
25A 60A
97.8%
Three indiators: Solar, Charging & Load Status
Three indiators: Solar, Battery &
Wiring Fault
98%
IP43 IP21
Connected Battery Type
Maximum Charging Current
Ripple Voltage
Maximum Efciency
Stanby Power Consumption
Charging Method
Yes
Yes
LCD Panel indicating Solar Power, Output Power, Battery Voltage, Charging Current, and Fault Conditions
24V 48V 12V
1W 2W
Nominal Battery Voltage
220 x 170 x 57.5
Input or Output Terminal Block
180 x 210 x 80 135 x 170 x 57.5
1.28 0.92
0~90% Relative Humidity (non-condensing)
-20C to 55C
-40C to 75C
0 ~ 3000m
Humidity
Operating Temperature
Storage Temperature
Altitude
1.85
Dimension (mm) D x W H
Net Weight (kgs)
Connector
Type of Mechanical Protection
50
Full Specications
PROLiNK Solar System
PSI Hybrid
HYBRID Series
Works as an On-grid inverter during the day
Works as an Off-grid inverter during the night or rainy conditions
Pure sine wave output
Multiple operations: Grid tie, Off grid, and grid-tie with backup
Built-in MPPT solar charger
LCD display panel for comprehensive information
Multiple communication interface
Green substitution for generators
PSI Hybrid Series is a hybrid inverter that combines the solar power
system, AC utility and battery power source to supply continuous power to
your home / ofce applications. This device is most suitable for rural areas
where electrical supply is unstable and inconsistent. The PSI Hybrid series
comes with a grid-tie operation mode where surplus electricity can be fed
back to the main grid, making it an economic and cost-effective power
option. If gaining access on the grid is not possible, the PSI Hybrid Series
also comes with an off-grid operation mode where power can be stored
directly to the back-up battery, making the Hybrid series one of most
versatile solar inverters in the market.
Solar
250VDC ~ 450VDC
360VDC
13A
500VDC Maximum DC Voltage
MPP Voltage Range
DC Nominal Voltage
Maximum Input Current
Capacity
47.5 ~ 50.2Hz AC Grid Frequency Range
Nominal AC Voltage/ Range
Nominal Output Current
Power Factor
INPUT (DC)
MODELS
3000W
HYBRID 3K
GRID/ UTILITY INPUT (AC)
GRID OUTPUT (AC)
ENVIRONMENT
INTERFACE
PHYSICAL
BATTERY & CHARGE
Nominal DC Voltage
Maximum Charging Current
BATTERY MODE OUTPUT (AC)
Output Voltage
Output Frequency
Output Waveform
Efciency (DC to AC)
20A
208/ 220/ 230/ 240VAC / 184 ~ 265VAC
Maximum Input Current
13A
>0.99
208/220/230/240 VAC
50Hz
Pure Sinewave
92%
48VDC
25A
Dimension (mm) D x W H 420 x 415 x 170
Net Weight (kgs) 15.5
208/ 220/ 230/ 240VAC / 175 ~ 280 VAC Nominal AC Voltage/ Range
RS-485/ RS-232
0~90% Relative Humidity (non-condensing)
0 ~ 1000m (Power derating 1% every 100m when altitude is over 1000m)
-25C to 60C
Humidity
Altitude
Operating Temperature
Optional SNMP Card and Modbus Card available
Optional Zigbee Card and Wireless device available
Communication Port
Intelligent Slot
Wireless Connection
*All specications, designs and contents are subject to change without prior notice.
51
Full Specications
PROLiNK Solar System
PSI On-Grid
AMNETS Series
1.5KW/2KW/3KW/5KW & 3-phase 10KW on-grid PV inverter
Advanced DSP control technology delivers accurate data
Smart MPPT technology enhances overall efciency
Modular design for easy maintenance
Industrial-grade components used for robust operation
Up to 15 years of data logging
Ingress Protection rated 65 (good for any type of environmental conditions)
Comprehensive LCD monitor for easy-reading
Free monitoring software
PSI On-Grid Series is a grid-connected photovoltaic power system that is
designed to operate at its optimum power output voltage even under
unfavourable weather conditions. This device uses high quality Amnetz
PV inverters to convert DC to AC power at a maximum conversion
efciency of up to 96%. On top of that, this user-friendly device is bundled
with a monitoring software kit that allows users to observe from a
graphical overview of the module voltage/current and temperature.
Solar
500VDC
150 ~ 500VDC
370VDC 600VDC 360VDC
116/ 150VDC 125/ 150VDC
11A 10A 16A 17A
250/ 250VDC
Maximum DC Power
Maximum DC Voltage
MPP Voltage Range
Nominal DC Voltage
Start-up Voltage/ Initial Feeding Voltage
Maximum Input Current/ Per String
Capacity
Phase
Maximum Efciency
DC Reverse-Polarity Protection
Ground Fault Monitoring
INPUT (DC)
MODELS
1500W
AMNETZ 1500
2000W
AMNETZ 2000
3000W
1 Phase-In 1 Phase-Out
>0.99
3 Phase-In 3 Phase-Out
AMNETZ 3000
5000W
AMNETZ 5000
10000W
1650W 2200W 3200W 5300W 11000W
450VDC 500VDC 500VDC 900VDC
230VAC 230VAC 230VAC 3/ N/ PE, 230/ 400VAC
6.6A 8.7A 21.7A 14.5A
150 ~ 400VDC 200 ~ 450VDC 320 ~ 800VDC
AMNETZ 10K
OUTPUT (AC)
EFFICIENCY
COMPLIANCE
ENVIRONMENT
INTERFACE
PHYSICAL
Intelligent Slot
PROTECTION
AC Short Circuit Protection
Grid Monitoring
Dimension (mm) D x W H
Net Weight (kgs)
230VAC
-20% ~ +15%
50Hz / 60Hz
13A
Nominal AC Voltage
AC Voltage Range
AC Grid Frequency
Nominal Output Current
Power Factor
96.0% 96.5% 98.0%
Yes
Yes
Yes
Yes
160 x 270 x 450 182 x 308 x 515 171.2 x 503.5 x 653.3 136.5 x 268.5 x 410
20 40 11.5 15
USB Card/ Optional: SNMP, RS-232, AS-400 and GPRS Cards
Operating Temperature
Humidity
-25 ~ 55C -25 ~ 60C -25 ~ 60C
0 ~ 100% Relative Humidity (Non-condesing)
Altitude 0 ~ 1000m (Power derating 1% every 100m when altitude is over 1000m)
CE, VDE 0126-1-1, IEC62109, ENEL Guide 2009, RD 1663, G83/ 1-1, AS3100/ AS4777 Standard
*All specications, designs and contents are subject to change without prior notice.
52
Full Specications
PROLiNK Solar System
PSI Off-Grid
OFFNETZ Series
DSP plus microprocessor redundant controllers
Pure sine wave output
Isolation design between inverter and battery
LCD Display and records data up to 15 years
Provides multiple communication ports for remote monitoring with software
Optional Modbus, SNMP, GPRS communication and AS400 dry contact
Option: On-Grid
PSI OFFNETZ Series is an off grid PV inverter that is best used in remote
locations without utility services. The device is able to supply generous
amount of electrical power to the load via PV modules, battery sources
and AC powered sources. The OFFNETZ Series is able to fully utilize the
energy from the sun to convert stable electrical power to any home /
commercial applications. In the event where it is not possible to draw
power from PV modules and battery sources, an AC power source can
still be supplied by a generator to get you through a rainy day.
Solar
*All specications, designs and contents are subject to change without prior notice.
250 ~ 450VDC
13A
100/ 110/ 120/ 127VAC
85 ~ 145VAC
208/ 220/ 230/ 240VAC
175 ~ 265VAC/ 175 ~ 280VAC
57.5 ~ 62.5Hz 47.5 ~ 52.2Hz
31A 20A
Maximum DC Voltage
Full Load MPP Voltage Range
Maximum Input Current
Nominal AC Voltage
Acceptable Voltage Range
Capacity
Overload Capability
Nominal DC Voltage
Dimension (mm) D x W H (Without Wheels)
PV INPUT (DC)
MODELS
2000W
OFFNETZ 2000
90% 92%
3000W
OFFNETZ 3000
500VDC 500VDC
100/ 110/ 120/ 127VAC 208/ 220VAC or 230/ 240VAC
170 ~ 450VDC
Acceptable Frequency Range
AC INPUT
BATTERY MODE OUTPUT (AC)
BATTERY & CHARGER
Humidity 0 ~ 90% Relative Humidity (non-condensing)
ENVIROMENT
INTERFACE
Communication Port
PHYSICAL
Operating Temperature
Altitude
Maximum Charging Current
Net Weight (kgs)
Intelligent Slot
60Hz 50Hz
Pure Sinewave
<3% @ Linear Load
>0.99
>110%: 5minutes; >150%: 1minute, 200%: Immediately
Output Voltage
Output Frequency
Output Waveform
THDv
Power Factor
Efciency (DC to AC)
48VDC
25A
15.5
RS-232/ USB
420 x 415 x 170
Optional SNMP Card, ModBus Card, GPRS, And AS-400 Card Available
0 ~ 40C
0 ~ 1000m (Power derating 1% every 100m when altitude is over 1000m)
Maximum Input Current
53
Full Specications
PROLiNK Solar System
PSI Off-Grid
HAUS Series
Pure sine wave inverter
Selectable input voltage range
Selectable charging current
Utility or Solar input priority conguration via LCD setting
Generator compatible
Auto restart while AC is recovering
Overload and short circuit protection
Cold start function
Optional N+1 parallel redundancy
The PSI HAUS Series is a wall-mounted off grid PV inverter that
employs a PWM technology. It is best used in remote locations
without utility services. The device is able to supply generous
amount of electrical power to the load via PV modules, battery
sources and AC powered sources. The HAUS Series is able to fully
utilize the energy from the sun to convert stable electrical power to
any home / commercial applications. In the event where it is
inapplicable to draw power from PV modules and battery sources,
an AC power source can still be supplied by a generator to get you
through a rainy day.
Solar
170 - 280 VAC (For Personal Computers)
90 - 280 VAC (For Home Applicances)
50 Hz / 60 Hz (Auto Sensing)
Voltage
Selectable Voltage Range
Frequency Range
Rated Power
INPUT
MODELS
1kVA / 800W
HAUS 1000
2kVA / 1.6kW
HAUS 2000
3kVA / 2.4kW
Pure sine wave
HAUS 3000
4kVA / 3.2kW
HAUS 4000
5kVA / 4kW
2000VA 4000VA 8000VA 10000VA
320 VAC
HAUS 5000
OUTPUT
Storage Temperature
Net Weight (kgs)
PHYSICAL
SOLAR CHARGER (OPTION)
Dimension, D X W X H (mm)
Maximum Charge Current
Charging Current
Maximum PV Array Open Circuit Voltage
230VAC 15%
6000VA
4.0 4.5 7.5 8.5 5.0
93%
10 ms (For Personal Computers)
AC Voltage Regulation (Batt. Mode)
Surge Power
Efciency (Peak)
Transfer Time
Waveform
12 VDC 24 VDC 48 VDC
13.5 VDC 27 VDC 48 VDC
10.5 VDC 21 VDC 42 VDC
15 VDC 30 VDC 60 VDC
10 A or 20 A 20 A or 30 A 20 A or 30 A
50A
125 VDC
92 x 272 x 347 110 x 300 x 455
Humidity
OPERATING ENVIRONMENT
5% to 95% Relative Humidity (Non-condensing)
Operating Temperature 0C to 55C
-15C to 60C
Battery Voltage
Floating Charge Voltage
BATTERY
Overcharge Protection
Low Battery Alarm Voltage
*All specications, designs and contents are subject to change without prior notice.
54
Full Specications
PROLiNK Solar System
PSS Series
Easy installation (No technicians needed)
Low cost
Converts solar energy to clean and usable electrical power
System is expandable (based on project requirements)
The PSS Series is a standalone solar power station that consists
of a solar charge controller, inverter and a battery pack. This cost
effective solar power station is able to provide clean power to
your home / commercial application. Sonnensys is designed
with a small footprint for easy installation and will surely t into
any corner of your limited workspace.
Solar
*All specications, designs and contents are subject to change without prior notice.
100 ~ 300VAC
50/ 60Hz (Auto-Sensing)
100 ~ 120VAC 5% or 200 ~ 2300VAC 5%
20ms Typical
200 ~ 230VAC 5% 230VAC 5%
Simulated Sinawave Pure Sinewave
Voltage
Selectable
Voltage Range
Ferquency Range
AC Voltage Regulation (Battery Mode)
Transfer Time
Capacity Volt-Amp/ Watt
For PCs
For Home Appliances
Floating Charge Voltage
INPUT (AC)
MODELS
850VA/ 480W
SONNENSYS 850
12VDC 24VDC
1500VA/ 1050W
SONNENSYS 1500 SONNENSYS 1500 PRO
120VAC or 230VAC 230VAC
95 ~ 145VAC or 180 ~ 260VAC 180 ~ 260VAC
50VDC 75VDC
50 ~ 160VAC or 100 ~ 300VAC
Waveform (Battery Mode)
OUTPUT (AC)
MPPT Range @ Operating Voltage 15 ~ 33VDC 30 ~ 66V
SOLAR CHARGER
BATTERY
Fault Continuously Sounding
Battery Replacement
ALARM
PHYSICAL
OPERATING EBVIRONMENT
PROTECTION
Low Battery
Maximum Charging Current 35A (10A AC Charger + 25A Solar Charger) or 45A (20A AC Charger + 25A Solar Charger)
Dimension (mm) D x W x H (Without Wheels)
Net Weight (kgs)
Humidity
Operating
Storage
Temperature
Full Protection
Overload
300W 600W
18A
1 x 12V100AH 2 x 12V100AH
13.7VDC 2% 27.4VDC 2%
Maximum PV Array Open Circuit Voltage
Maximum PV Array Power
Maximum Charging Current
Number & Type of Battery
Battery Voltage
Overload & Short Circuit Protection
Sounding every second
Sounding every 0.5 seconds
Sounding every 2 seconds
480 x 250 x 450
53 92
0 ~ 90% Relative Humidity (Non-condensing)
0C ~ 50C
-15C ~ 70C
94
480 x 420 x 420
55
16A maximum input current
Powered by two separate independent power sources
Dual power supply for redundancy
Provides seamless power switch for IT equipment
Preferred source selection on front panel
19 rack-mount design (1U)
Built-in USB and RS-232 interface
Full Specications
PROLiNK Online UPS Accessories
Automatic Transfer Switch
PROLiNK Automatic Transfer Switch (ATS) is designed to allow two independent power inputs to supply power to the
connected load. In the event where the primary power source fails, the ATS automatically transfers the backup
connection to the secondary power source without any interruption, providing seamless electrical power and the highest
protection for your equipment. The PROLiNK ATS is also designed to automatically transfer the connection back to the
primary power source once it has detected restored power.
Software & Accessories
*All specications, designs and contents are subject to change without prior notice.
207 ~ 253VAC
50Hz/ 60Hz
230VAC Input Voltage
Acceptable Input Voltage
Input Frequency
Current Rating
8xIEC-C13; 1xIEC-C19 Output
Input
Communication
Transfer Time
INPUT
MODELS
16A
ATS16-R
OUTPUT
CONNECTION
ENVIRONMENT
Operating Temperature
PHYSICAL
Dimension (mm) D x W x H
Net Weight (kgs)
10A for IEC-C13 Outlets; 16A for IEC-C19 Outlets
2xIEC-C20 Inlets
Maximum Output Current
USB/ RS-232
9 ~ 12ms (Typical)
310 x 430 x 44
3.65
20 ~ 95% Relative Humidity @ -5C ~ 45C (non-condensing)
230VAC Output Voltage
56
16A for 208/220/230/240 VAC
Provides continuous power to connecting equipment during UPS maintenance
Easy operation with simple rotary switch and indicators
Master-slave function for energy saving
Multiple sockets to support more devices
Choose between a rack or tower design to t into any working environment
Simple installation with plug-and-play socket type
Suitable for all UPSs up to 3kVA
Full Specications
PROLiNK Online UPS Accessories
PDU & Maintenance
Bypass Switch
The PDU & Maintenance Bypass Switch is an external power
distribution unit used in conjunction with UPS systems or
large-scale voltage regulators. This device enables the UPS to be
isolated for scheduled maintenance or replacement without
interrupting the power to the load. Designed with a
master-controller concept, the PROLiNK PDU is able to handle
both the maintenance bypass function and power saving function
effectively.
Software & Accessories
I = IEC, U = UK, S = EU, N = Nema
*All specications, designs and contents are subject to change without prior notice.
IEC

UK NEMA Schuko
Yes. When power consumption in Master Outlet is lower
than 20W (5W), it will shut off the power for slave outlets.
NA Master/ Slave Function
Current Rating
5 x NEMA 20A Sockets 6 x NEMA 20A Sockets
PHYSICAL
Voltage Rating 208/ 220/ 230/ 240/VAC
MODELS
16A
MBS16-R (I/U/S/N) (*) MBS16-T (I/U/S/N) (*)
Output
Net Weight (kgs)
CONNECTION
ENVIRONMENT
Operating Temperature
Dimension (mm)
D x W x H
IEC
Schuko
UK
NEMA
5 x IEC 10A Socket + 1 x IEC 16A Socket (with 2 circuit breakers) 8 x IEC 10A Socket + 1 x IEC 16A Socket (with 2 circuit breakers)
4 x Schuko 16A Sockets
4 x UK 13A Sockets
80 x 438 x 50 180 x 160 x 50
80 x 438 x 60 180 x 200 x 50
80 x 438 x 50 180 x 160 x 50
1.50 1.30
20 ~ 95% Relative Humidity @ -0C ~ 40C (non-condensing)
1 x IEC (16A) Connector & 1 x Customized Plug Cable
1 x IEC (16A) Connector & 1 x Cable (16A ~ 10A IEC Cable for 1k/ 2k, 16A ~ 16A IEC cable for 3k)
Input
NEMA
UK
UPS Input
Schuko
IEC
UPS Output
AC Power
57
Allows control and monitoring of multiple UPSs through RJ-45 network connection
Real-time dynamic graphs reflecting UPS data (Voltage, frequency, load level and
battery level)
Warning notications via audible alarm, broadcast, mobile messenger,
e-mail and SNMP traps
Historical data logging
One click easy rmware upgrade
Password security protection and remote access management
Supports optional environmental monitoring detector for temperature, humidity and smoke
PROLiNK Online UPS Accessories
SNMP Card
Software & Accessories
Integrated with our latest ViewPower software, the SNMP manager operates as an enhanced
communication solution for your UPS system. It allows you to remotely manage and monitor
your UPS system via internet connectivity. Once connected to the internet, the ViewPower
software provides you access to remotely program or even shut down your UPS system.
Adopts ModBus RTU Protocol
Comes with functions that includes read Holding Registers and write Registers
RS232 and RS485 interface
Modbus Card
The ModBus Card provides UPS and PV inverter systems with the functionality to
communicate with PCs through the ModBus Protocol.
Capable of selecting the status of the dry-contact signal by setting the jumper to meet
different application requirements
Suitable applications include; IBM Server, Personal PC & Workstations equipments,
Auto-controlled industrial equipment & communication applications
AS-400 Card
The AS-400 communication card is designed with a high quality contact closure board that
accurately converts UPS signals into dry contacts for users to monitor UPS events that are
most concerned to them. By setting the jumper, the AS-400 communication card allows you to
select various status indicators such as; UPS alarm, UPS failure, Bypass, Low Battery etc.
Simple and easy installation
Suitable for PROLiNK Rack Mount Online UPS system
Slider length available in 700mm and 11100mm to suit different types of cabinet
Rack Mount Slider
The PROLiNK Rack-mount slider kit offers you the best solution to install a PROLiNK UPS
system into a 19 server rack enclosure. This kit comes with a pair of heavy duty sliders that
are attached with quality assured ball bearings to ensure that your server can slide effortlessly
into and out of the rack. Furthermore, the PROLiNK Rack-mount slider kit includes a superior
quality front and rear mounting brackets to withstand the weight of your UPS.
58
Allows control and monitoring of multiple UPSs via
LAN and INTERNET
User-friendly power analysis graphs
Real-time dynamic graphs of UPS data
Safety OS shutdown to prevent data losses during
power failure
Warning notications via audible alarm, broadcast,
mobile messenger, and e-mail
Scheduled UPS on/off, battery test, programmable
outlet control, and audible alarm control
Password security protection and remote access
management
Supports multiple OS and local languages
PROLiNK Online UPS Software
Viewpower UPS Management Software
Software & Accessories
ViewPower is an advanced UPS management software that is designed for users to remotely monitor and manage
multiple UPS units in a networked environment, either by LAN or INTERNET. The ViewPower software is able to protect
your important data by executing a safety OS shutdown during power failure. Better yet, this software gives users the
ability to store programming data and also scheduled a UPS shutdown when necessary.
Allows control and monitoring of multiple devices
via LAN and INTERNET
Automatic and real-time data acquisition
Secure data logging
Graphic display of device data for quick and easy
reading
Warning notications or fault alarms via audible
alarm, pop-up screen, broadcast, mobile messenger,
tray message and e-mail
Easy diagnosis from event statistics and amount
calculation for energy saving
Maximum data log up to 10 billion records
Supports online upgrade and manually upgrade
Supports multiple languages: English, Chinese,
French, German, Spanish, Russian, Portuguese,
Ukrainian, Italian, Polish
Solar Power Management Software
SolarPower Pro is a solar inverter monitoring software that is capable of monitoring up to 247 devices via a modbus
interface. When connected to a networking environment, users are able to monitor the Solar inverter via a web browser. The
SolarPower Pro comes with a variety of features including; data logging, ability to generate statistical data, alarm
notications, prompting fault messages and parameter control for devices.
59
PROLiNK UPS Battery Backup Conguration List
1. Professional Series (1P/1P) - Tower
Appendix
PRO903L
PRO906L
PRO901L
PRO902L
6/72VDC
8/96VDC
2/24VDC
4/48VDC
C1*1
12V26AH*2
C2*1
12V26AH*4
C3*1
12V26AH*6
C4*1
12V17AH*16
C1*1
12V17AH*4
C2*1
12V17AH*8
C3*1
12V17AH*12
C8*1
12V26AH*16
C2*1
12V65AH*2
C4*1
12V65AH*4
C6*1
12V65AH*6
C8*1
12V100AH*8
C3*1
12V100AH*2
C4*1
12V100AH*4
C6*1
12V100AH*6
C24*1
12V65AH*24
PC96*1
C6*1
12V65AH*6
PEC20-24*1
C12*1
12V65AH*12
PEC15-48*1
C20*1
12V65AH*18
PEC12-72*1
C32*1
12V65AH*32
PEC10-96*2
POWER
RATING
BACK UP
TIME
1. Without cable from
UPS system to
battery bank.
2. All batteries supply
are without battery
cables.
BATTERY
GROUP
QUANTITY
15 MINUTES
QUANTITY
30 MINUTES
QUANTITY
1 HOUR
QUANTITY
2 HOURS
QUANTITY
3 HOURS
C8*1
12V65AH*8
PEC20-24*1
C16*1
12V65AH*16
PEC15-48*1
C24*1
12V65AH*24
PEC12-72*1
C20*2
12V65AH*40
PEC10-96*3
QUANTITY
4 HOURS
REMARK
DC BUS
(VDC)
2. Master Series (1P/1P) - Tower
PRO802L
PRO803L
PRO801L
PRO8015L
6/72VDC
6/72VDC
3/36VDC
3/36VDC
C1*1
12V17AH*3
C1*1
12V26AH*3
C2*1
12V17AH*6
C3*1
12V26AH*6
C1*1
12V26AH*3
C2*1
12V17AH*6
C3*1
12V26AH*6
C3*1
12V17AH*12
C3*1
12V26AH*6
C3*1
12V65AH*3
C6*1
12V26AH*12
C6*1
12V65AH*6
C3*1
12V65AH*3
C3*1
12V100AH*3
C6*1
12V65AH*6
C6*1
12V100AH*6
PEC12-72*1
C6*1
12V100AH*6
PEC15-36*1
C12*1
12V65AH*12
PEC15-36*2
C12*1
12V100AH*12
PEC12-72*1
C20*1
12V65AH*18
PEC12-72*1
PRO806L 20/240VDC
C6*1
12V17AH*20
C12*1
12V26AH*20
C4*2
12V18AH*40
C20*1
12V26AH*40
PEC24-240*1
C20*2
12V65AH*40
PEC24-240*1
PRO810L 20/240VDC
C12*1
12V26AH*20
C6*2
12V17AH*40
C20*1
12V65AH*20
C20*1
12V100AH*20
PEC24-240*2
C20*2
12V100AH*40
PEC24-240*1
POWER
RATING
BACK UP
TIME
1. Without cable from
UPS system to
battery bank.
2. All batteries supply
are without battery
cables.
BATTERY
GROUP
QUANTITY
15 MINUTES
QUANTITY
30 MINUTES
QUANTITY
1 HOURS
QUANTITY
2 HOURS
QUANTITY
4 HOURS
C6*1
12V65AH*6
PEC15-36*1
C6*1
12V100AH*6
PEC15-36*1
C20*1
12V26AH*36
PEC12-72*1
C12*1
12V100AH*12
PEC12-72*1
C20*1
12V100AH*20
PEC24-240*1
C20*3
12V65AH*60
PEC24-240*1
QUANTITY
4 HOURS
REMARK
DC BUS
(VDC)
3. Master Series (1P/1P) - Combo
PRO806CL
PRO810CL
20/240VDC
20/240VDC
C6*1
12V17AH*20
C12*1
12V26AH*20
C12*1
12V26AH*20
C6*2
12V17AH*40
C6*2
12V17AH*40
C20*1
12V65AH*20
C20*1
12V26AH*40
PEC24-240*1
C20*1
12V100AH*20
C20*2
12V65AH*40
PEC24-240*1
C20*2
12V100AH*40
PEC24-240*1
POWER
RATING
BACK UP
TIME
1. Without cable from UPS
system to battery bank.
2. All batteries supply are
without battery cables.
BATTERY
GROUP
QUANTITY
15 MINUTES
QUANTITY
30 MINUTES
QUANTITY
1 HOURS
QUANTITY
2 HOURS
QUANTITY
4 HOURS
C20*1
12V100AH*20
PEC24-240*1
C20*3
12V65AH*60
PEC24-240*1
QUANTITY
3 HOURS
REMARK
DC BUS
(VDC)
The above battery backup conguration list is only applicable to the isolation transformer UPS version.
All specications, designs and contents are subjected to changes without prior notice.
60
4. Master Series (1P/1P) - 2-in-1 Rack/ Tower
Appendix
5. Master Series (3P/1P) - Tower
6. Master Series (3P/1P) - Rack Mount
PRO83110RL
PRO83120RL
20
20
G20R*3
12V9AH*60
C12*2
12V26AH*40
C4*2
12V17AH*40
C12*3
12V26AH*60
C20*1
12V65AH*20
C20*2
12V65AH*40
PEC24-240*1
C20*1
12V100AH*20
PEC24-240*1
C20*2
12V100AH*40
PEC24-240*1
C20*2
12V100AH*40
PEC24-240*1
C20*4
12V100AH*80
PEC24-240*2
POWER
RATING
BACK UP
TIME
BATTERY
GROUP
QUANTITY
15 MINUTES
QUANTITY
30 MINUTES
QUANTITY
1 HOURS
QUANTITY
2 HOURS
QUANTITY
4 HOURS
C20*3
12V65AH*60
PEC24-240*1
C20*6
12V65AH*120
PEC24-240*2
QUANTITY
3 HOURS
REMARK
DC BUS
(VDC)
1. Without cable from UPS
system to battery bank.
2. All batteries supply are
without battery cables.
The above battery backup conguration list is only applicable to the isolation transformer UPS version.
*All specications, designs and contents are subject to change without prior notice.
PRO802RL
PRO803RL
PRO801RL
PRO8015RL
4/48VDC
6/72VDC
2/24VDC
3/36VDC
G8R*1
12V7AH*8
G12R*1
12V7AH*12
G20R*1
12V7AH*16
G12R*2
12V7AH*24
C1*1
12V17AH*4
C2*1
12V17AH*6
C2*1
12V17AH*8
C3*1
12V17AH*12
C2*1
12V65AH*2
C3*1
12V65AH*3
C4*1
12V65AH*4
C6*1
12V65AH*6
C3*1
12V100AH*2
PEC20-24*1
C3*1
12V100AH*3
PEC15-36*1
C4*1
12V100AH*4
PEC15-48*1
C6*1
12V100AH*6
PEC12-72*1
C8*1
12V65AH*8
PEC20-24*1
C12*1
12V65AH*12
PEC15-36*2
C16*1
12V65AH*16
PEC15-48*2
C24*1
12V65AH*24
PEC12-72*2
PRO806RL 20/240VDC
G20R*2
12V9AH*40
C12*1
12V26AH*20
C20*1
12V26AH*40
PEC24-240*1
C20*1
12V65AH*20
PEC24-240*1
C20*3
12V65AH*60
PEC24-240*1
PRO810RL 20/240VDC
G20R*4
12V7AH*80
C20*1
12V26AH*40
C20*1
12V100AH*20
PEC24-240*1
C20*2
12V65AH*40
PEC24-240*1
C20*4
12V65AH*80
PEC24-240*1
POWER
RATING
BACK UP
TIME
BATTERY
GROUP
QUANTITY
15 MINUTES
QUANTITY
30 MINUTES
QUANTITY
1 HOURS
QUANTITY
2 HOURS
QUANTITY
4 HOURS
C6*1
12V65AH*6
PEC20-24*1
C6*1
12V100AH*6
PEC15-36*1
C12*1
12V65AH*12
PEC15-48*1
C20*1
12V65AH*18
PEC12-72*1
C20*2
12V65AH*40
PEC24-240*1
C20*2
12V100AH*40
PEC24-240*1
QUANTITY
3 HOURS
DC BUS
(VDC)
1. Without cable from
UPS system to
battery bank.
2. All batteries supply
are without battery
cables.
REMARK
PRO83120L
PRO83110L
PRO83115L
20
20
20
C12*1
12V26AH*20
C6*2
12V17AH*40
C12*2
12V26AH*40
C6*2
12V17AH*40
C20*1
12V26AH*40
C12*3
12V26AH*60
C20*1
12V65AH*20
C20*1
12V100AH*20
C20*2
12V65AH*40
PEC24-240*1
C20*1
12V100AH*20
PEC24-240*1
C20*2
12V100AH*40
PEC24-240*1
C20*2
12V100AH*40
PEC24-240*1
C20*2
12V100AH*40
PEC24-240*1
C20*3
12V100AH*60
PEC24-240*1
C20*4
12V100AH*80
PEC24-240*2
POWER
RATING
BACK UP
TIME
1. Without cable from
UPS system to
battery bank.
2. All batteries supply
are without battery
cables.
BATTERY
GROUP
QUANTITY
15 MINUTES
QUANTITY
30 MINUTES
QUANTITY
1 HOURS
QUANTITY
2 HOURS
QUANTITY
4 HOURS
C20*3
12V65AH*60
PEC24-240*1
C20*4
12V65AH*80
PEC24-240*1
C20*6
12V65AH*120
PEC24-240*2
QUANTITY
3 HOURS
REMARK
DC BUS
(VDC)
PRO83130L 20
C20*1
12V65AH*20
C20*1
12V100AH*20
PEC24-240*1
C20*2
12V100AH*40
PEC24-240*1
C20*3
12V100AH*60
PEC24-240*1
C20*7
12V100AH*140
PEC24-240*3
C20*5
12V100AH*100
PEC24-240*2
1. Without cable from UPS
system to battery bank.
2. All batteries supply are
without battery cables.
61
8. Power Series (3P/3P)
The above battery backup conguration list is only applicable to the isolation transformer UPS version.
*All specications, designs and contents are subject to change without prior notice.
PRO73330S
PRO73340S
PRO73315S
PRO73320S
62
62
62
62
C16*1
12V17AH*62
C16*1
12V17AH*62
C32*1
12V26AH*62
C16*2
12V17AH*124
C32*1
12V26AH*62
C16*2
12V17AH*124
C32*2
12V26AH*124
C16*2
12V17AH*124
C16*2
12V17AH*124
C32*2
12V65AH*62
C32*2
12V100AH*62
C32*2
12V26AH*124
C32*2
12V65AH*62
C32*2
12V100AH*62
C32*4
12V65AH*124
C32*4
12V65AH*124
C32*4
12V65AH*124
C32*4
12V100AH*124
C32*8
12V65AH*248
PRO73360S 62
C32*1
12V26AH*124
C32*2
12V65AH*62
C32*4
12V65AH*124
C32*4
12V100AH*124
C32*8
12V100AH*248
PRO73380S 62
C32*2
12V65AH*62
C32*2
12V100AH*62
C32*6
12V65AH*186
C32*8
12V65AH*248
C32*10
12V100AH*310
POWER
RATING
BACK UP
TIME
1. Without cable from
UPS system to
battery bank.
2. All batteries supply
are without battery
cables.
BATTERY
GROUP
QUANTITY
15 MINUTES
QUANTITY
30 MINUTES
QUANTITY
1 HOURS
QUANTITY
2 HOURS
C32*2
12V100AH*62
C32*2
12V100AH*62
C32*6
12V65AH*186
C32*4
12V100AH*124
C32*6
12V100AH*186
C32*8
12V100AH*248
QUANTITY
3 HOURS
QUANTITY
4 HOURS
REMARK
DC BUS
(VDC)
PRO733100S 62
C32*2
12V65AH*62
C32*4
12V65AH*124
C32*4
12V100AH*124
C32*6
12V100AH*186
C32*14
12V100AH*434
C32*10
12V100AH*310
PRO733120S 62
C32*2
12V65AH*62
C32*4
12V100AH*124
C32*8
12V65AH*248
C32*8
12V100AH*248
C32*16
12V100AH*496
C32*12
12V100AH*372
PRO83320L
PRO83310L
PRO83315L
20
20
20
C12*1
12V26AH*20
C6*2
12V17AH*40
C12*2
12V26AH*40
C4*2
12V17AH*40
C20*1
12V26AH*40
C12*3
12V26AH*60
C20*1
12V65AH*20
C20*1
12V100AH*20
C20*2
12V65AH*40
PEC24-240*1
C20*1
12V100AH*20
PEC24-240*1
C20*2
12V100AH*40
PEC24-240*1
C20*2
12V100AH*40
PEC24-240*1
C20*2
12V100AH*40
PEC24-240*1
C20*3
12V100AH*60
PEC24-240*1
C20*4
12V100AH*80
PEC24-240*2
POWER
RATING
BACK UP
TIME
1. Without cable from
UPS system to
battery bank.
2. All batteries supply
are without battery
cables.
BATTERY
GROUP
QUANTITY
15 MINUTES
QUANTITY
30 MINUTES
QUANTITY
1 HOURS
QUANTITY
2 HOURS
QUANTITY
4 HOURS
C20*3
12V65AH*60
PEC24-240*1
C20*4
12V65AH*80
PEC24-240*1
C20*6
12V65AH*120
PEC24-240*2
QUANTITY
3 HOURS
DC BUS
(VDC)
REMARK
PRO83330L 20
C20*1
12V65AH*20
C20*1
12V100AH*20
PEC24-240*1
C20*2
12V100AH*40
PEC24-240*1
C20*3
12V100AH*60
PEC24-240*1
C20*7
12V100AH*140
PEC24-240*3
C20*5
12V100AH*100
PEC24-240*2
7. Master Series (3P/3P) - Tower
Appendix
1. Without cable from UPS
system to battery bank.
2. All batteries supply are
without battery cables.
62
The above battery backup conguration list is only applicable to the isolation transformer UPS version.
*All specications, designs and contents are subject to change without prior notice.
Battery Congurations
MODEL NO
1. Option for DC
switch/protection
2. Option for battery
cable inter
connection.
For Power Series
Included cables,
without switch
CABINET
DIMENSION
(D * W * H)
100AH 65AH 38AH
Available Battery Quantity
24AH 17AH
12V7AH or
12V9AH or 10Ah
CABINET WEIGHT
REMARK
CI
C2
C3
C4
C6
C8
C12
C16
C20
C24
C32
G6
G12
G18
G60
G8R
G12R
G20R
/
/
/
/
/
/
/
/
/
/
/
6
12
18
60
8
12
20
Completed assembled
Completed assembled
Completed assembled
completed assembled
Completed assembled
Completed assembled
Completed assembled
435*210*270
450*470*320
585*470*320
450*470*615
585*470*615
780*470*615
780*470*900
780*470*1190
950*470*1190
1150*470*1190
780*880*1190
1
1
3
4
6
8
12
16
20
24
32
1
2
3
4
6
8
12
16
20
24
32
2
4
6
8
12
16
24
32
40
/
62
3
4
6
8
12
16
24
32
40
/
62
5
10
14
20
28
36
/
62
/
/
/
3.5kg
6kg
8kg
18kg
22kg
25kg
32kg
45kg
45kg
75kg
95kg
Appendix
63
Note
Note
64
SINGAPORE
FIDA INTERNATIONAL (S) PTE LTD
Block 16 Kallang Place
#06-02, Singapore 339156
Tel: (65) 6357 0668
MALAYSIA
FIDA SYSTEMS (M) SDN BHD
Tel: (60) 3 8024 9151
INDONESIA
PROLiNK INDONESIA
Tel: (62) 21 3483 1777
Technical Support Hotline:
Singapore (65) 6357 0666
Malaysia (60) 3 8023 9151
Indonesia (62) 21 3482 1717
Operating Hours
Monday - Friday: 9.00am - 6.00pm
Closed on Saturdays, Sundays & Public Holidays

Вам также может понравиться