Вы находитесь на странице: 1из 12

EUREKA

FIREWATER PUMP SYSTEMS


STATFJORD A, STATOIL
SNORRE B, STATOIL
TROLL C, SHELL
CLAIR, BP
FPSO FARWAH, TOTAL
OSEBERG SR, STATOIL
SGARD A, STATOIL
KRISTIN, STATOIL
AGBAMI FPSO, CHEVRON
OVER 120 FIREWATER PUMP SYSTEMS
delivered to the offshore oil & gas industry
ENSURE SAFETY THROUGH EXPERIENCE
Fire protection for all offshore units
SKARV, BP GOLIAT, ENI GRANE, STATOIL
2
Diesel direct driven dry mounted pump
Diesel electric driven deepwell pump
(dry-mounted motor)
Diesel-electric driven deepwell pump with
angle gear (Caisson mounted)
Diesel electric driven dry-mounted pump
THE FEATURES OF
EUREKA FIREWATER PUMP SYSTEMS
EUREKA PUMPS AS
supplies firewater pump packages with
pumps powered either directly by diesel
engines, by diesel-electric generators, or
by electric dry mounted motors.
The Eureka firewater system includes a
driver, a pump, and a control system with
no need for utility consumption in
operation mode.
The systems and pumps are in accordance
with NFPA 20 regulations.
NFPA20 designed systems: We are
following the guidelines and principles
of the NFPA 20 standard. The pump is
rated for for 150% capacity on 65%
of the rated head output. The drivers
used are either diesel-electric or diesel
direct driven. No hydraulics are used.
Large capacities and high
pressures: The firewater pumps are
designed for high output and low
energy demand. The Eureka Pumps
has no limitation to capacity and
pressures required for firewater pump
applications on offshore units today.
Low System complexity: Through
simplicity we achieve higher reliability
and lesser possible failure modes. The
Eureka firewater system design is clean
with few parts and few interfaces. Due
to the high output of our pumps we
can do the job with only one pump.
Complete systems: We supply
complete firewater pump packages. All
types of enclosures can be delivered.
Control systems may be simple NFPA
20 controllers or PLC systems with
multiple functions. Extra fuel tanks, fin
fan coolers and AFFF systems can be
supplied.
Self contained systems: The Eureka
firewater pump systems are self-
contained and fully operational for 24
hours with all auxiliary equipment. No
external influence can stop the
firewater pump in a fire emergency
situation.
Firewater pump system configurations
3
DIRECT DIESEL DRIVEN DEEPWELL
FIREWATER PUMP WITH ANGLE GEAR
The most reliable offshore firewater pump system today
Features
Space, weight and cost efficient due to
few and simple components.
Simple installation and easy alignment.

Reinforced vertical bearing
arrangement and non-reverse ratchet.
Driver and control equipment is located
away from flood exposed areas with
solid connection to the submerged
pump.
Non-return valve.
Robust, complete and fully mechanical
NFPA 20 designed system.
- Option for operation in hazardous area.
The pump is a line shaft, end suction
multistage centrifugal pump driven by a
high-speed direct injection turbo charged
diesel engine. The cooling water taken
from pump discharge and the complete
system is independent of external cooling
water.
Pump drive is through a short cardan
shaft from engine to a right angle gear.
The common base plate for pump, engine,
gear and accessories is fitted with a large
capacity drip pan.
Control Panel, start batteries, fuel tank
and other accessories can be mounted on
the base plate.
Description
Firewater Pump
Type : Vertical multi-stage deepwell centrifugal
Standard : API 610
Capacity : up to 5000 m
3
/h
Total head : up to 220mlc
Shaft seal : Labyrinth seal
Material : Duplex, Superduplex or NI-Al br
Driver : High speed turbocharged diesel engine through right
bevel type angle gear
4
Pump Unit
None retuern valve
Shaft
Sleeve coupling
Split ring
Riser column
Shaft key
Riser column flange
Spider bearing
Journal bearing
Pump Bowl
Pump Shaft
Sleeve bearings
Impeller
Shaft sleeve
Wear rings
Split ring
Impeller cap
Locking screw
Suction bell
DIRECT DIESEL DRIVEN DEEPWELL
FIREWATER PUMP WITH ANGLE GEAR
The most reliable offshore firewater pump system today
As the only supplier in the world Eureka
can deliver a unique non-return valve
located next to the submerged firewater
pump. The non-return valve will keep the
firewater piping system filled at all times,
and hence, reduce the water hammering
effects
Non return valve Deepwell API 610 type
(length to 50 meters)
The Eureka deepwell pump is a vertical
turbine product lubricated line shaft type
pump. It is designed according to API 610
for continuous pumping duty under all
operating conditions. For seawater duty
the pump is delivered in 25%Cr Duplex or
22%Cr Duplex or Ni-Al Bronze material.
The drive shaft is always delivered in
25%Cr Duplex
Top Unit & Gear
Riser/transmission
Trust
bearing
Input shaft
Lub oil
sump
Non-reverse
ratchet
Water leakage
drain
Pump bend
Pump top
shaft
Flange to
top riser
Lub oil pump
Lub oil inlet
Angle gear
housing
Bevel gear
Hollow shaft
Lub oil outlet
Shaft oil seal
Deflector ring
Shaft seal
Cooling water outlet
Labyrinth seal
5
SYSTEM COMPONENTS
Control system is fully NFPA 20 controller
based PLC systems with multiple
functions and easy interfacing.
Control system
Standard electric start motor fitted to the
engine and hooked up to battery banks Air
driven start system and hydraulic start
system can also be supplied
Start Systems
Combustion Exhaust
Silencer & Cooler
Fuel day tank for 12, 18 or 24 hours
operation. Skid mounted or loose supply.
Fuel Day tank
High-speed direct injection
turbocharged marine diesel engines
rated for 12-24 hours (according to
requirements) for continuous operation
plus 10% overload capacity.
Complete units for fire-water or
generator set duties.
Engine systems supplied for direct drive
of pumps or generators. Generator
drives may be used for electric drive of
pumps or as emergency generator sets.
Mounted on skids or in complete A60 to
H120 enclosures.
Diesel drivers
Fire extinguishing Arrangement.
Fire extinguishing system with local and
remote release (gas).
AFFF skid
Combined A60/H60 and sound damping
module with full width walkways around
engine and pump. Access doors and
removable hatches for easy installation/
removal and maintenance.
Enclosures
Main and standby ventilation fans for
enclosure ventilation.
Ventilation Fans
Made in SS316 L. Installed in/on
enclosure. Baffle type combustion air
silencer for sound reduction to 85 (75)
dB(A).
Combustion air silencer
6
SELECTED REFERENCES FOR DIRECT DRIVEN
LINE SHAFT FIREWATER PUMP PACKAGES
The most reliable offshore firewater pump system today
Grane
Statfjord A
Maui B
Clair
Year of Order 2000
End-User Norwegian Hydro
Location Grane
Units 4
Model/size CD450-2
Motor size (kW) 1850
Length (m) 43
Diff. Head (mLC) 185
Capacity (m
3
/h) 2350
Speed (rpm) 1550
Year of Order 1975
End-User Statoil
Location Statfjord A
Units 2
Model/size CL-250-4
Motor size (kW) 670
Length (m) 48
Diff. Head (mLC) 148
Capacity (m
3
/h) 960
Speed (rpm) 1170
Year of Order 1990
End-User Shell
Location Maui B
Units 1
Model/size CL200-4
Motor size (kW) 475
Length (m) 37
Diff. Head (mLC) 158
Capacity (m
3
/h) 630/905
Speed (rpm) 1650
Year of Order 2002
End-User BP
Location Clair
Units 2
Model/size CD250-3
Motor size (kW) 800
Length (m) 44,5
Diff. Head (mLC) 165
Capacity (m3/h) 1050
Speed (rpm) 1410
7
DIRECT DIESEL DRIVEN DRY-MOUNTED
FIREWATER PUMP SYSTEM
Simple mechanical pump room solution
Features
Low system complexity with few
components and direct drive.
Easy accessible for maintenance.
Large capacity range.
Straight forward NFPA 20 design.
- Option for operation in hazardous area.
The firewater pump is a dry mounted
single or double suction single stage
centrifugal pump in horizontal version
for standby operation. Driven by high-
speed direct injection turbo charged and
after cooled diesel engine. The cooling
water taken from pump discharge and
the complete system is independent of
external cooling water.
Pump drive through a flexible cardan
coupling arrangement to simplify
installation/alignment and to permit the
diesel engine to move freely on its
flexible supports. A heavy duty,
lightweight base frame fitted with drip
pan with drain connection.
A 4-point standard skid mounting
arrangement with spherical rubber
bushings and weld pad supports.
Description
Firewater Pump - Marine
Type : Single or double suction, singel stage
centrifugal
Standard : Marine class
Capacity : up to 4000m
3
/h
Total head : up to 200mlc
Shaft seal : Single mechanical
Material : Ni-Al Br (recommended)
Driver : High speed turbocharged diesel engine
Firewater Pump - API610
Type : Double suction single stage radial split
centrifugal
Standard : API 610
Capacity : up to 10.000 m
3
/h
Total head : up to - 400mlc
Shaft seal : Single mechanical
Material : Ni-Al-Br, Duplex, or SuperDuplex
Driver : High speed turbocharged diesel engine
8
DIESEL -ELECTRIC DRIVEN DRY-MOUNTED
FIREWATER PUMP SYSTEM
The flexible pump room firewater solution
Dry mounted firewater pump diesel electric
drive unit for standby or marine duty. Diesel
engine drive through a flanged on
generator.
Driven by high speed direct injection
turbocharged and after cooled diesel
engine. The cooling water taken from pump
discharge and the complete system is
independent of external cooling water
Water cooled generator flanged onto engine
fly wheel housing and supported in flexible
mounts matched to engine mounts.
Freshwater cooled double tube heat
exchanger in CuNi complete with leakage
alarm.
Heavy duty, light weight frame fabricated in
carbon steel. Fitted with large capacity drip
pan with drain connection.
Skid mounted NFPA20 type controller,
microprocessor based, with built in
instrument battery. Full generator
instrumentation.
Description
Features
Straight NFPA 20 system design.
Flexibility in installation arrangement.
Possibility for combined Firewater and
Seawater Lift pump duty, and
combined power supply.
- Option for operation in hazardous area.
Dry-mounted
marine type
Electrical or diesel driven single or double
stage, double suction, double volute, radial
split pump. It is available both in vertical and
horizontal execution. From a performance
point of view, the pump is designed with high
efficiency.
Dry-mounted API 610 type
Direct electric or direct diesel driven API 610
vertical or horizontal skid mounted FW pump.
The pump is a single stage, double suction,
double volute, radial split centrifugal pump.
The pump can be delivered in a wide range of
capacity and head specification.
Firewater Pump - API610
Type : Double suction single stage radial
split centrifugal
Standard : API 610
Capacity : up to 10.000 m3/h
Total head : up to - 400mlc
Shaft seal : Single mechanical
Material : Ni-Al-Br, Duplex or SuperDuplex
Driver : High speed turbocharged diesel
engine
Firewater Pump - Marine
Type : Single or double suction, single
stage centrifugal
Standard : Marine class
Capacity : up to 4000m3/h
Total head : up to 200mlc
Shaft seal : Single mechanical
Material : Ni-Al Br (recommended)
Driver : High speed turbocharged diesel
engine
9
MODIFICATION OF
FIRE WATER PUMP SYSTEMS IN OPERATION
10
Detail knowledge of NFPA20 Fire Water
Pump System configurations:
Required Power consumption and
efficiency
Dynamic considerations of total system
Control and instrumentation according to
NFPA20
System HSE requirements
SIL/PED/ATEX requirements
Maintenance philosophy
Detail knowledge of all components in
Fire Water pump system train for all
NFPA20 configurations. Pump, Diesel
engine, Generator, Elmotor, Angle gear,
Control unit, Auxiliaries
Firewater Pump upgrading for
increased capacity and head according
to new requirements.
Upgrade of existing control system or
replacement with new control system
to meet new requirements.
Upgrading of diesel engine to improve
reliability and increased power output.
Tailor maid maintenance systems of
diesel engine, generator, gear, elmotor
and pump according to manufacturer
requirements
Evaluation of optimal system or
component selection for modification
of existing firewater equipment.
Cooperation with manufacturers for
key components.
Conditional monitoring to evaluate
optimal working conditions
Capacity measurement
Conditional monitoring
11
3MW diesel generator set to BP FPSO Skarv - Fire Water Pump package
Part of
EUREKA PUMPS AS
Agent
Oslo
Rio
Houston
Korea
Malaysia
Singapore
India
Dubai
Stavanger
Kristiansund N
France
|
0
0
1
0
EUREKA PUMPS AS, Magnus Poulssons vei 7, NO-1366 Lysaker, Telephone: + 47 815 31 002, www.eureka.no
EUREKA PUMPS AS is a pump supplier with 30 years experience in the oil and gas industry, offering a
range of pumps that covers the majority of pump applications. EUREKA PUMPS supplies newbuildings
and operates advanced maintenance and service. The company also offers services within upgrading,
modifications, equipment testing, and installation. EUREKA PUMPS is a market leader among
companies operating on the Norwegian Continental shelf, and it is also present in international markets
with selected applications based on own technology. EUREKA PUMPS main office is at Lysaker, and it
has branch offices at strategic locations along the Norwegian coast. EUREKA PUMPS also has offices in
Houston and Rio.
EUREKA PUMPS is one of five companies in the ALIGN group, a leading supplier of production
equipment and safety critical products and solutions. ALIGN offers services ensuring continuous
production, a perspective that safeguards optimal operations and lower life-cycle costs. ALIGN is a result
of the demerger of Bjrge AS, which was carried out in December 2010. The ALIGN group is owned by
Converto Capital and HitecVision. ALIGN is a result of the demerger of Bjrge AS, which was carried out
in December 2010.

Вам также может понравиться