Intertek Testing Services Taiwan Ltd.

Intertek 5F, No. 423, Ruiguang Road, Neihu District,


Taipei 114, Taiwan
Tel.: (+886-2) 6602 2888

Fax: (+886-2) 6602 2415

Test Verification of Conformity

On the basis of the tests undertaken, the sample(s) of the below product have been found
to comply with the essential requirements of the referenced specifications at the time the
tests were carried out.

Applicant Name & Address Tranwo Technology Corp.


6F., No. 49, Guangming e" Rd., Jubei City, Hsinchu 302, Taiwan
Product(s) Tested Digital Wireless Video Baby Monitor
Ratings and principal Monitor: 6 Vdc, 800 mA

characteristics
Camera: 6 Vdc, 800 mA
Class III
Model(s) Monitor: TTD-61 R

Camera: TTD-41T

Brand name TRANWO


Relevant EN 60950-1: 2001 + A11: 2004

Standard(s)/Speclfication(s)

NOTE: The equipment covered by this document is, subject .to


mandatory compliance with - the European LVD Directive
2006/95/EC.

Verification Issuing Office Name & Intertek Testing Services Taiwan Ltd.

Address 5F, No. 423, Ruiguang Road, Neihu District, Taipei 114, Taiwan

Verification/Report Number(s) TP08100045-ETS (TP081 00045-ETS)

NOTE 1: This verification is part of the full test report(s) and should be read in conjunction with it.

NOTE 2: See Annex for additional infonnation

NOTE: This annex is part of the Test Verification of Conformity and should be read in conjunction with it.

This Verification is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility
and liability are limited to the terms and conditions of the agreement. Inertek assumes no liability to any party, other than to the Client in accordance with the
agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to copy or distribute this Verification.
Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by
Intertek. The observations and test results referenced from this Verification are relevant only to the sample tested. This Verification by itself does not imply
that the material, product, or service is or has ever been under an Intertek certification program.

SAMMY WU
SENIOR MANAGER
q j SEMKO DIVISION

October 30, 2008

www.intertek.com Page 1 of 2
Intertek Testing Services Taiwan ltd.
SF, No. 423, Ruiguang Road, Neihu District,
Intertek Taipei 114, Taiwan
Tel.: (+886-2) 6602 2888

Fax: (+886-2) 6602 2415

Annex to Test Verification of Conformity

This is an Annex to Test Verification of Conformity with Verification/Report Number(s):


TP0810004S-ETS (TP0810004S-ETS). The issuing office Is Intertek Testing Services Taiwan Ltd.
(Address: SF, No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan).

Additional information Monitor and Camera:


For use only with power supply, mfr. LINKE, Type LK-D060080.
Monitor:
For use only with Battery pack, mfr. L1CO, Type H11T19.

NOTE: This annex is part of the Test Verification of Conformity and should be read in conjunction with it.
This Verification is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility
and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the
agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to copy or distribute this Verification.
Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by
Intertek. The observations and test results referenced from this Verification are relevant only to the sample tested. This Verification by itself does not imply
that the material, product, or service is or has ever been under an Intertek certification program.

SAMMY WU
SENIOR MANAGER
FTl SEMKO DIVISION

October 30,2008

www.intertek.com Page 2 of 2
Intertek

Page 1 of 56 TP08100045-ETS

TEST REPORT

iac 60950-1 and/or EN 60950-1

Information technology equipment - Safety ­

Part 1: General requirements

Report reference No : TP08100045-ETS


Tested by
/Jd ~
(printed name and signature) : Una Lin ........... l.~~ .
~
Approved by
(printed name and signature) : Albert Wang .. .
Date of issue : October 30, 2008
Contents : : 56 oaces test report + Photos, 11 pages.
Testing laboratory name . Intertek Testing Services Taiwan Ltd.
Address : 5F, No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan
Testing location : CBTL ~ CCATL 0 SMT 0 TMP 0
Address : Same as above
Applicant's name .
Tranwo Technology Corp.
Address : 6F., No. 49, Guangming s" Rd., Jubei City, Hsinchu 302, Taiwan

Test specification
Standard : IEC 60950-1: 2001, First Edition and/or EN 60950-1: 2001 + A11:
2004
Test procedure : CE marking service
Procedure deviation Group differences and special national deviations of all CENELEC
countries.
Non-standard test method N/A
Test Report Form No : IECEN60950_1 B
TRF originator : SGS Fimko Ltd
Master TRF : dated 2003-03
Copyright © 2003 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE),
Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposesas long as the IECEE is acknowledged as copyright
owner and source of the material. IECEEtakes no responsibility for and will not assume liabilityfor damages resulting from the reader's
interpretation of the reproduced materialdue to its placement and context.

Test item description : Digital Wireless Video Baby Monitor


Trademark : TRANWO
Manufacturer : Same as applicant
Model and/or type reference : Monitor: TTD-61R
Camera: TTD-41 T
Serial number : -
Rating(s) : Monitor: 6 Vdc, 800 mA
Camera: 6 Vdc, 800 mA
Class III

TRF No.: IECEN60950_1B


Page 2 of 56 TP08100045-ETS

Copy of marking plate:


(Representative)
(Monitor)

(Camera)

Below Sentence is necessary while the flammability class HB enclosure is used.


Monitor and Camera: For use only with power supply, mfr. LINKE, Type LK-D060080.
Monitor: For use only with Battery pack, mfr. LICO, Type H11T19.
Note:
The above markings are the minimum requirements required by the safety standard. For the final
production sample, the additional markings which do not give rise to misunderstanding may be added.

TRF No.: IECEN60950_1B


Page 3 of 56 TP08100045-ETS

Summary of testing:
The sample(s) tested complies with the requirements of EN 60950-1: 2001 + A11: 2004.
Compliance with the National requirements of “(countries)” as given in CB Bulletin "(112A)" was also
confirmed.
1.6.2 Input current test
1.7.13 Marking durability test
2.2.2 Voltage under normal conditions test
2.2.3 Voltage under Fault Conditions Test
2.5 Limited power source test
4.1 EUT stabilization - 10° tilted test
4.2.4 Mechanical strength – steady force test, 250 N
4.2.5 Mechanical strength – steel ball impact test
4.2.6 Mechanical strength – drop test
4.2.7 Mechanical strength – stress relief test
4.2.10 Mechanical strength – mounting means test
4.3.8 Batteries charging circuit test
4.5.1 Normal operating test
5.3 Abnormal operating and fault conditions test

TRF No.: IECEN60950_1B


Page 4 of 56 TP08100045-ETS

Particulars: test item vs. test requirements


Equipment mobility ..................................... : Moveable (Transportable)
Operating condition ..................................... : Continuous
Mains supply tolerance (%) ......................... : ⎯
Tested for IT power systems ...................... : No
IT testing, phase-phase voltage (V) ........... : ⎯
Class of equipment ..................................... : Class III
Mass of equipment (kg) ............................... : Monitor: approx. 120 g (with battery)
Camera: approx. 240 g (with battery and Supporting Stand)
Protection against ingress of water ............ : IPX0
Test case verdicts
Test case does not apply to the test object : N/A (Not Applicable)
Test item does meet the requirement ......... : P (Pass)
Test item does not meet the requirement ... : F (Fail)
Testing
Date of receipt of test item .......................... : October 15, 2008
Date(s) of performance of test .................... : October 22, 2008 ~ October 27, 2008
General remarks
“This report is not valid as a CB Test Report unless appended by an approved CB Testing
Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02”.
The test result presented in this report relate only to the object(s) tested.
This report shall not be reproduced, except in full, without the written approval of the issuing testing
laboratory.
“(see Appendix #)” refers to additional information appended to the report.
“(see appended table #)” refers to a table appended to the report.
Throughout this report a comma (point) is used as the decimal separator.
Throughout this report a comma (point) is used as the decimal separator.
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between
Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the
agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the
agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is
authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek
name or one of its marks for the sale or advertisement of the tested material, product or service must first
be approved in writing by Intertek. The observations and test results in this report are relevant only to the
sample tested. This report by itself does not imply that the material, product, or service is or has ever been
under an Intertek certification program.
The test report only allows to be revised within three years from its original issued date unless further
standard or the requirement was noticed.
When determining the test conclusion, the Measurement Uncertainty of test has been considered.

TRF No.: IECEN60950_1B


Page 5 of 56 TP08100045-ETS

General product information:


The equipment is a Digital Wireless Video Baby Monitor for residential or commercial environment use and
considered as movable and transportable Class III equipment.
Monitor and Camera: For use only with power supply, mfr. LINKE, Type LK-D060080.
Monitor: For use only with Battery pack, mfr. LICO, Type H11T19.
The equipment was submitted and evaluated for maximum manufacturer’s recommended ambient (Tmra)
of 35 °C.

TRF No.: IECEN60950_1B


Page 6 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

1 GENERAL

1.5 Components
1.5.1 General P
Comply with IEC 60950-1 or relevant component (see appended table 1.5.1) P
standard
1.5.2 Evaluation and testing of components P
1.5.3 Thermal controls No such component within the N/A
EUT
1.5.4 Transformers No such component within the N/A
EUT
1.5.5 Interconnecting cables No such component within the N/A
EUT
1.5.6 Capacitors in primary circuits ............................. : No such component within the N/A
EUT
1.5.7 Double insulation or reinforced insulation bridged No such component within the N/A
by components EUT
1.5.7.1 General N/A
1.5.7.2 Bridging capacitors N/A
1.5.7.3 Bridging resistors N/A
1.5.7.4 Accessible parts N/A
1.5.8 Components in equipment for IT power systems N/A

1.6 Power interface


1.6.1 AC power distribution systems Class III equipment N/A
1.6.2 Input current (see appended table 1.6.2) P
1.6.3 Voltage limit of hand-held equipment The EUT is not hand-held N/A
equipment
1.6.4 Neutral conductor The EUT is Class III equipmet N/A

TRF No.: IECEN60950_1B


Page 7 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

1.7 Marking and instructions


1.7.1 Power rating The EUT is not directly supplied N/A
by AC mains
Rated voltage(s) or voltage range(s) (V) ............ : Same as above N/A
Symbol for nature of supply, for d.c. only............ : Same as above N/A
Rated frequency or rated frequency range (Hz) : Same as above N/A
Rated current (mA or A) ..................................... : Same as above N/A
Manufacturer’s name or trademark or TRANWO P
identification mark .............................................. :
Monitor: TTD-61R
Type/model or type reference ............................. : P
Camera: TTD-41T
Symbol of for Class II equipment only ............... : The EUT is Class III equipment N/A
Other symbols .................................................... : Additional symbols or marking P
do not give rise to
misunderstanding
Certification marks ............................................. : N/A
1.7.2 Safety instructions P
1.7.3 Short duty cycles The EUT is continuous N/A
operating type
1.7.4 Supply voltage adjustment ................................. : Only one power supply voltage N/A
1.7.5 Power outlets on the equipment ........................ : No such component within the N/A
EUT
1.7.6 Fuse identification .............................................. : No such component within the N/A
EUT
1.7.7 Wiring terminals The EUT is Class III equipment N/A
1.7.7.1 Protective earthing and bonding terminals ........ : N/A
1.7.7.2 Terminal for a.c. mains supply conductors N/A
1.7.7.3 Terminals for d.c. mains supply conductors N/A
1.7.8 Controls and indicators P
1.7.8.1 Identification, location and marking .................... : No safety relevant control or N/A
indicator
1.7.8.2 Colours .............................................................. : The LED is illuminated when P
the EUT is operating and colour
is only used for functional
indicator

TRF No.: IECEN60950_1B


Page 8 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

1.7.8.3 Symbols according to IEC 60417........................ : N/A


1.7.8.4 Markings using figures ...................................... : No figures used as marking N/A
1.7.9 Isolation of multiple power sources .................... : The EUT is Class III equipment N/A
1.7.10 IT power distribution systems N/A
1.7.11 Thermostats and other regulating devices No such device within the EUT N/A
1.7.12 Language ........................................................... : English. However, the local ⎯
language for each country that
would be marketed shall be
provided before the national
approval
1.7.13 Durability After rubbing test by water and P
petroleum spirit, the marking
still legible; it is not easily
possible to remove the marking
plate and show no curling
1.7.14 Removable parts The marking is located on the P
enclosure can not be replaced
1.7.15 Replaceable batteries The warning for replaceable P
lithium battery is marked in both
the operating and the service
instructions
Language ............................................................ : English. However, the local ⎯
language for each country that
would be marketed shall be
provided before the national
approval
1.7.16 Operator access with a tool ................................ : No such area N/A
1.7.17 Equipment for restricted access locations .......... : The EUT is not such type N/A

TRF No.: IECEN60950_1B


Page 9 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

2 PROTECTION FROM HAZARDS

2.1 Protection from electric shock and energy hazards


2.1.1 Protection in operator access areas The EUT is Class III equipment, P
no hazardous live parts within
the EUT
2.1.1.1 Access to energized parts N/A
Test by inspection .............................................. : N/A
Test with test finger ............................................ : N/A
Test with test pin ................................................ : N/A
Test with test probe ............................................ : N/A
2.1.1.2 Battery compartments ........................................ : No TNV circuits within the EUT N/A
2.1.1.3 Access to ELV wiring No ELV circuits within the EUT N/A
Working voltage (V); minimum distance (mm) ⎯
through insulation
2.1.1.4 Access to hazardous voltage circuit wiring N/A
2.1.1.5 Energy hazards .................................................. : No energy hazard in operator P
access area
2.1.1.6 Manual controls No such device N/A
2.1.1.7 Discharge of capacitors in equipment The EUT is Class III equipment N/A
Time-constant (s); measured voltage (V)............ : ⎯
2.1.2 Protection in service access areas N/A
2.1.3 Protection in restricted access locations N/A

2.2 SELV circuits


2.2.1 General requirements P
2.2.2 Voltages under normal conditions (V)................. : All accessible voltages are less P
42.4 Vpeak or 60 Vdc and are
classified as SELV circuits

TRF No.: IECEN60950_1B


Page 10 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

2.2.3 Voltages under fault conditions (V) ..................... : Single fault did not cause P
excessive voltage in accessible
SELV circuits. Limits of 71
Vpeak and 120 Vdc were not
exceeded within 0.2 s and limits
42.4 Vpeak and 60 Vdc were
not exceeded for longer than 0.2
s
2.2.3.1 Separation by double insulation or reinforced N/A
insulation (method 1)
2.2.3.2 Separation by earthed screen (method 2) N/A
2.2.3.3 Protection by earthing of the SELV circuit N/A
(method 3)
2.2.4 Connection of SELV circuits to other circuits ...... : SELV circuits only connected to P
SELV circuits

2.3 TNV circuits


2.3.1 Limits No TNV circuits within the EUT N/A
Type of TNV circuits............................................ : ⎯
2.3.2 Separation from other circuits and from N/A
accessible parts
Insulation employed ............................................ : ⎯
2.3.3 Separation from hazardous voltages N/A
Insulation employed ............................................ : ⎯
2.3.4 Connection of TNV circuits to other circuits N/A
Insulation employed ............................................ : ⎯
2.3.5 Test for operating voltages generated externally N/A

2.4 Limited current circuits


2.4.1 General requirements No considered N/A
2.4.2 Limit values N/A
Frequency (Hz) ................................................... : ⎯
Measured current (mA) ....................................... : ⎯
Measured voltage (V).......................................... : ⎯
Measured capacitance (μF) ................................ : ⎯

TRF No.: IECEN60950_1B


Page 11 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

2.4.3 Connection of limited current circuits to other N/A


circuits

2.5 Limited power sources


Inherently limited output Test with battery pack which is P
complied with Limited Power
Source
Impedance limited output N/A
Overcurrent protective device limited output N/A
Regulating network limited output under normal P
operating and single fault condition
Regulating network limited output under normal N/A
operating conditions and overcurrent protective
device limited output under single fault condition
Output voltage (V), output current (A), apparent (see appended tables 25) ⎯
power (VA) .........................................................:
Current rating of overcurrent protective device (A) ⎯

2.6 Provisions for earthing and bonding


2.6.1 Protective earthing The EUT is Class III equipment N/A
2.6.2 Functional earthing N/A
2.6.3 Protective earthing and protective bonding N/A
conductors
2.6.3.1 General N/A
2.6.3.2 Size of protective earthing conductors N/A
2
Rated current (A), cross-sectional area (mm ), ⎯
AWG.................................................................... :
2.6.3.3 Size of protective bonding conductors N/A
Rated current (A), cross-sectional area (mm2), ⎯
AWG.................................................................... :
2.6.3.4 Resistance (Ω) of earthing conductors and their N/A
terminations, test current (A)............................... :
2.6.3.5 Colour of insulation ............................................. : N/A
2.6.4 Terminals N/A
2.6.4.1 General N/A

TRF No.: IECEN60950_1B


Page 12 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

2.6.4.2 Protective earthing and bonding terminals N/A


Rated current (A), type and nominal thread ⎯
diameter (mm)..................................................... :
2.6.4.3 Separation of the protective earthing conductor N/A
from protective bonding conductors
2.6.5 Integrity of protective earthing N/A
2.6.5.1 Interconnection of equipment N/A
2.6.5.2 Components in protective earthing conductors N/A
and protective bonding conductors
2.6.5.3 Disconnection of protective earth N/A
2.6.5.4 Parts that can be removed by an operator N/A
2.6.5.5 Parts removed during servicing N/A
2.6.5.6 Corrosion resistance N/A
2.6.5.7 Screws for protective bonding N/A
2.6.5.8 Reliance on telecommunication network or cable N/A
distribution system

2.7 Overcurrent and earth fault protection in primary circuits


2.7.1 Basic requirements The EUT is Class III equipment N/A
Instructions when protection relies on building N/A
installation
2.7.2 Faults not covered in 5.3 N/A
2.7.3 Short-circuit backup protection N/A
2.7.4 Number and location of protective devices ........ : N/A
2.7.5 Protection by several devices N/A
2.7.6 Warning to service personnel ............................. : N/A

2.8 Safety interlocks


2.8.1 General principles No safety interlock or similar N/A
devices used within the EUT
2.8.2 Protection requirements N/A
2.8.3 Inadvertent reactivation N/A

TRF No.: IECEN60950_1B


Page 13 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

2.8.4 Fail-safe operation N/A


2.8.5 Moving parts N/A
2.8.6 Overriding N/A
2.8.7 Switches and relays N/A
2.8.7.1 Contact gaps (mm) ............................................. : N/A
2.8.7.2 Overload test N/A
2.8.7.3 Endurance test N/A
2.8.7.4 Electric strength test N/A
2.8.8 Mechanical actuators N/A

2.9 Electrical insulation


2.9.1 Properties of insulating materials Only Functional Insulation is P
considered and complied with
sub-clause 5.3.4
2.9.2 Humidity conditioning N/A
Humidity (%) ....................................................... : ⎯
Temperature (°C) ............................................... : ⎯
2.9.3 Grade of insulation P

2.10 Clearances, creepage distances and distances through insulation


2.10.1 General Only Functional Insulation is P
considered and complied with
sub-clause 5.3.4
2.10.2 Determination of working voltage N/A
2.10.3 Clearances N/A
2.10.3.1 General N/A
2.10.3.2 Clearances in primary circuit N/A
2.10.3.3 Clearances in secondary circuits N/A
2.10.3.4 Measurement of transient voltage levels N/A
2.10.4 Creepage distances N/A
CTI tests.............................................................. : ⎯

TRF No.: IECEN60950_1B


Page 14 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

2.10.5 Solid insulation N/A


2.10.5.1 Minimum distance through insulation N/A
2.10.5.2 Thin sheet material N/A
Number of layers (pcs)........................................ : ⎯
Electric strength test ⎯
2.10.5.3 Printed boards N/A
Distance through insulation N/A
Electric strength test for thin sheet insulating ⎯
material
Number of layers (pcs)........................................ : N/A
2.10.5.4 Wound components N/A
Number of layers (pcs)........................................ : N/A
Two wires in contact inside wound component; N/A
angle between 45° and 90° ................................:
2.10.6 Coated printed boards N/A
2.10.6.1 General N/A
2.10.6.2 Sample preparation and preliminary inspection N/A
2.10.6.3 Thermal cycling N/A
2.10.6.4 Thermal ageing (°C)............................................: N/A
2.10.6.5 Electric strength test ⎯
2.10.6.6 Abrasion resistance test N/A
Electric strength test ⎯
2.10.7 Enclosed and sealed parts..................................: N/A
Temperature T1=T2 = Tma – Tamb +10K (°C)........: N/A
2.10.8 Spacings filled by insulating compound..............: N/A
Electric strength test ⎯
2.10.9 Component external terminations N/A
2.10.10 Insulation with varying dimensions N/A

TRF No.: IECEN60950_1B


Page 15 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

3 WIRING, CONNECTIONS AND SUPPLY

3.1 General
3.1.1 Current rating and overcurrent protection P
3.1.2 Protection against mechanical damage Smooth wireways P
3.1.3 Securing of internal wiring All internal wirings are suitable P
fixed
3.1.4 Insulation of conductors The insulation of the individual P
conductors is suitable for the
application and the working
voltage. For the insulation
material see 3.1.1
3.1.5 Beads and ceramic insulators N/A
3.1.6 Screws for electrical contact pressure N/A
3.1.7 Insulating materials in electrical connections N/A
3.1.8 Self-tapping and spaced thread screws N/A
3.1.9 Termination of conductors N/A
10 N pull test N/A
3.1.10 Sleeving on wiring N/A

3.2 Connection to an a.c. mains supply or a d.c. mains supply


3.2.1 Means of connection .......................................... : The EUT is Class III equipment N/A
3.2.1.1 Connection to an a.c. mains supply N/A
3.2.1.2 Connection to a d.c. mains supply N/A
3.2.2 Multiple supply connections N/A
3.2.3 Permanently connected equipment N/A
Number of conductors, diameter (mm) of cable ⎯
and conduits ....................................................... :
3.2.4 Appliance inlets N/A
3.2.5 Power supply cords N/A

TRF No.: IECEN60950_1B


Page 16 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

3.2.5.1 AC power supply cords N/A


Type .................................................................... : ⎯
2
Rated current (A), cross-sectional area (mm ), ⎯
AWG....................................................................:
3.2.5.2 DC power supply cords N/A
3.2.6 Cord anchorages and strain relief N/A
Mass of equipment (kg), pull (N) .......................: ⎯
Longitudinal displacement (mm) ........................: ⎯
3.2.7 Protection against mechanical damage N/A
3.2.8 Cord guards N/A
D (mm); test mass (g) ........................................: ⎯
Radius of curvature of cord (mm) .......................: ⎯
3.2.9 Supply wiring space N/A

3.3 Wiring terminals for connection of external conductors


3.3.1 Wiring terminals No wiring terminal N/A
3.3.2 Connection of non-detachable power supply N/A
cords
3.3.3 Screw terminals N/A
3.3.4 Conductor sizes to be connected N/A
Rated current (A), cord/cable type, cross- ⎯
sectional area (mm2) ........................................... :
3.3.5 Wiring terminal sizes N/A
Rated current (A), type and nominal thread ⎯
diameter (mm) .................................................... :
3.3.6 Wiring terminals design N/A
3.3.7 Grouping of wiring terminals N/A
3.3.8 Stranded wire N/A

TRF No.: IECEN60950_1B


Page 17 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

3.4 Disconnection from the mains supply


3.4.1 General requirement The EUT is Class III equipment N/A
3.4.2 Disconnect devices N/A
3.4.3 Permanently connected equipment N/A
3.4.4 Parts which remain energized N/A
3.4.5 Switches in flexible cords N/A
3.4.6 Single-phase equipment and d.c. equipment N/A
3.4.7 Three-phase equipment N/A
3.4.8 Switches as disconnect devices N/A
3.4.9 Plugs as disconnect devices N/A
3.4.10 Interconnected equipment N/A
3.4.11 Multiple power sources N/A

3.5 Interconnection of equipment


3.5.1 General requirements SELV to SELV P
3.5.2 Types of interconnection circuits......................... : SELV circuits P
3.5.3 ELV circuits as interconnection circuits No ELV interconnection circuits N/A

TRF No.: IECEN60950_1B


Page 18 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

4 PHYSICAL REQUIREMENTS

4.1 Stability
Angle of 10° The cradle does not P
overbalance at 10°
Test: force (N) ..................................................... : The mass of EUT is less than N/A
25 kg and not a floor-standing
unit

4.2 Mechanical strength


4.2.1 General No safety concerns about P
electric shock, mechanical and
chemical hazards in this unit
4.2.2 Steady force test, 10 N N/A
4.2.3 Steady force test, 30 N N/A
4.2.4 Steady force test, 250 N The EUT is still complying with P
relevant requirements of this
standard
4.2.5 Impact test P
Fall test P
Swing test P
4.2.6 Drop test After 1 m drop, EUT are still P
complying with relevant
requirements of this standard
4.2.7 Stress relief test 70 °C / 7 hours, all the P
enclosure materials listed in the
table 1.5.1 are tested. No risk
of shrinkage or distortion on
enclosures due to release of
internal stresses
4.2.8 Cathode ray tubes No such device within the EUT N/A
Picture tube separately certified..........................: N/A
4.2.9 High pressure lamps No such device within the EUT N/A
4.2.10 Wall or ceiling mounted equipment; force (N) ....: 50 N P

TRF No.: IECEN60950_1B


Page 19 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

4.3 Design and construction


4.3.1 Edges and corners The outer surface of the EUT is P
smoothed. No sharp edges and
corners
4.3.2 Handles and manual controls; force (N) .............: No such device within the EUT N/A
4.3.3 Adjustable controls No such device within the EUT N/A
4.3.4 Securing of parts The enclosures are fixed P
together by screws
4.3.5 Connection of plugs and sockets No such device within the EUT N/A
4.3.6 Direct plug-in equipment The EUT is not direct plug-in N/A
equipment
Dimensions (mm) of mains plug for direct N/A
plug-in .............................................................. :
Torque and pull test of mains plug for direct N/A
plug-in; torque (Nm); pull (N) .............................. :
4.3.7 Heating elements in earthed equipment No such device within the EUT N/A
4.3.8 Batteries The protective device for P
battery cell is provided within
the battery pack
4.3.9 Oil and grease No such material within the N/A
EUT
4.3.10 Dust, powders, liquids and gases The EUT does not produce N/A
such thing
4.3.11 Containers for liquids or gases No such device within the EUT N/A
4.3.12 Flammable liquids ...............................................: No such material is used N/A
Quantity of liquid (l) .............................................: N/A
Flash point (°C) ...................................................: N/A
4.3.13 Radiation; type of radiation ................................: See sub-clause 4.3.13.5 P
4.3.13.1 General P
4.3.13.2 Ionizing radiation The EUT does not generate N/A
ionizing radiation
Measured radiation (pA/kg) ................................ : ⎯
Measured high-voltage (kV) ............................... : ⎯
Measured focus voltage (kV) ............................. : ⎯
CRT markings .................................................... : ⎯

TRF No.: IECEN60950_1B


Page 20 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

4.3.13.3 Effect of ultraviolet (UV) radiation on materials N/A


Part, property, retention after test, flammability N/A
classification ....................................................... :
4.3.13.4 Human exposure to ultraviolet (UV) radiation .... : N/A
4.3.13.5 Laser (including LEDs) P
Laser class ......................................................... : The LEDs are considered as ⎯
complying with the requirement
of Class 1 LED product
4.3.13.6 Other types ......................................................... : N/A

4.4 Protection against hazardous moving parts


4.4.1 General No hazardous moving parts N/A
within the EUT
4.4.2 Protection in operator access areas N/A
4.4.3 Protection in restricted access locations N/A
4.4.4 Protection in service access areas N/A

4.5 Thermal requirements


4.5.1 Maximum temperatures (see appended table 4.5) P
Normal load condition per Annex L..................... : See Annex L.7 P
4.5.2 Resistance to abnormal heat N/A

4.6 Openings in enclosures


4.6.1 Top and side openings P
Dimensions (mm) ............................................... : (see appended table 4.6.4) ⎯
4.6.2 Bottoms of fire enclosures All components in secondary N/A
circuits are supplied by LPS
and mounted on V-1 class
material, so fire enclosure is
unnecessary
Construction of the bottom .................................. : ⎯
4.6.3 Doors or covers in fire enclosures No such device within the EUT N/A
4.6.4 Openings in transportable equipment (see appended table 4.6.4) P
4.6.5 Adhesives for constructional purposes N/A
Conditioning temperature (°C)/time (weeks)....... : ⎯

TRF No.: IECEN60950_1B


Page 21 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

4.7 Resistance to fire


4.7.1 Reducing the risk of ignition and spread of flame See sub-clause 4.7.2.2 P
Method 1, selection and application of (see appended table 4.7) P
components wiring and materials
Method 2, application of all of simulated fault N/A
condition tests
4.7.2 Conditions for a fire enclosure N/A
4.7.2.1 Parts requiring a fire enclosure N/A
4.7.2.2 Parts not requiring a fire enclosure Supplied by limited power P
source complying with sub-
clause 2.5 and mounted on
materials of flammability class
min. V-1
4.7.3 Materials P
4.7.3.1 General (see appended table 1.5.1) P
4.7.3.2 Materials for fire enclosures See clause 4.7.2.2 N/A
4.7.3.3 Materials for components and other parts outside N/A
fire enclosures
4.7.3.4 Materials for components and other parts inside N/A
fire enclosures
4.7.3.5 Materials for air filter assemblies No such assembly within the N/A
EUT
4.7.3.6 Materials used in high-voltage components No such component within the N/A
EUT

TRF No.: IECEN60950_1B


Page 22 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS

5.1 Touch current and protective conductor current


5.1.1 General The EUT is Class III equipment N/A
5.1.2 Equipment under test (EUT) N/A
5.1.3 Test circuit N/A
5.1.4 Application of measuring instrument N/A
5.1.5 Test procedure N/A
5.1.6 Test measurements N/A
Test voltage (V) ..................................................: ⎯
Measured touch current (mA) ............................: ⎯
Max. allowed touch current (mA) .......................: ⎯
Measured protective conductor current (mA) ....: ⎯
Max. allowed protective conductor current (mA) : ⎯
5.1.7 Equipment with touch current exceeding The EUT is not such equipment N/A
3.5 mA ..............................................................:
5.1.8 Touch currents to and from telecommunication No TNV circuits within the EUT N/A
networks and cable distribution systems and from
telecommunication networks
5.1.8.1 Limitation of the touch current to a No TNV circuits within the EUT N/A
telecommunication network and a cable
distribution system
Test voltage (V) ..................................................: ⎯
Measured touch current (mA) ............................: ⎯
Max. allowed touch current (mA) .......................: ⎯
5.1.8.2 Summation of touch currents from No TNV circuits within the EUT N/A
telecommunication networks.............................. :

5.2 Electric strength


5.2.1 General The EUT is Class III equipment N/A
5.2.2 Test procedure N/A

TRF No.: IECEN60950_1B


Page 23 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

5.3 Abnormal operating and fault conditions


5.3.1 Protection against overload and abnormal The EUT is Class III P
operation equipment, no hazardous live
parts or hazardous energy level
within the EUT
5.3.2 Motors No such devices N/A
5.3.3 Transformers No such devices N/A
5.3.4 Functional insulation ...........................................: Method c) P
5.3.5 Electromechanical components No such component within EUT N/A
5.3.6 Simulation of faults P
5.3.7 Unattended equipment There are no thermostats and N/A
similar components within the
EUT
5.3.8 Compliance criteria for abnormal operating and P
fault conditions
5.3.8.1 During the tests P
5.3.8.2 After the tests P

TRF No.: IECEN60950_1B


Page 24 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

6 CONNECTION TO TELECOMMUNICATION NETWORKS

6.1 Protection of telecommunication network service persons, and users of


other equipment connected to the network, from hazards in the equipment
6.1.1 Protection from hazardous voltages N/A
6.1.2 Separation of the telecommunication network from earth N/A
6.1.2.1 Requirements No TNV circuits with the EUT N/A
Test voltage (V) ..................................................: ⎯
Current in the test circuit (mA) .........................: ⎯
6.1.2.2 Exclusions ...........................................................: N/A

6.2 Protection of equipment users from overvoltages on telecommunication


networks
6.2.1 Separation requirements No TNV circuits with the EUT N/A
6.2.2 Electric strength test procedure N/A
6.2.2.1 Impulse test N/A
6.2.2.2 Steady-state test N/A
6.2.2.3 Compliance criteria N/A

6.3 Protection of the telecommunication wiring system from overheating


Max. output current (A) .......................................: No TNV circuits with the EUT ⎯
Current limiting method .......................................: ⎯

TRF No.: IECEN60950_1B


Page 25 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

7 CONNECTION TO CABLE DISTRIBUTION SYSTEMS

7.1 Protection of cable distribution system service N/A


persons, and users of other equipment
connected to the system, from hazardous
voltages in the equipment
7.2 Protection of equipment users from overvoltages N/A
on the cable distribution system
7.3 Insulation between primary circuits and cable N/A
distribution systems
7.3.1 General N/A
7.3.2 Voltage surge test N/A
7.3.3 Impulse test N/A

TRF No.: IECEN60950_1B


Page 26 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

A ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE N/A


A.1 Flammability test for fire enclosures of movable equipment having a total mass N/A
exceeding 18 kg, and of stationary equipment (see 4.7.3.2)
A.1.1 Samples ..............................................................: The EUT is not such equipment ⎯
Wall thickness (mm)............................................: ⎯
A.1.2 Conditioning of samples; temperature (°C).........: N/A
A.1.3 Mounting of samples ...........................................: N/A
A.1.4 Test flame (see IEC 60695-11-3) N/A
Flame A, B, C or D .............................................: ⎯
A.1.5 Test procedure N/A
A.1.6 Compliance criteria N/A
Sample 1 burning time (s) ...................................: ⎯
Sample 2 burning time (s) ...................................: ⎯
Sample 3 burning time (s) ...................................: ⎯
A.2 Flammability test for fire enclosures of movable equipment having a total mass not N/A
exceeding 18 kg, and for material and components located inside fire enclosures
(see 4.7.3.2 and 4.7.3.4)
A.2.1 Samples, material ............................................... : ⎯
Wall thickness (mm)............................................: ⎯
A.2.2 Conditioning of samples N/A
A.2.3 Mounting of samples N/A
A.2.4 Test flame (see IEC 60695-11-4) N/A
Flame A, B or C ..................................................: ⎯
A.2.5 Test procedure N/A
A.2.6 Compliance criteria N/A
Sample 1 burning time (s) ...................................: ⎯
Sample 2 burning time (s) ...................................: ⎯
Sample 3 burning time (s) ...................................: ⎯
A.2.7 Alternative test acc. to IEC 60695-2-2, cl. 4 and 8 N/A
Sample 1 burning time (s) ...................................: ⎯
Sample 2 burning time (s) ...................................: ⎯
Sample 3 burning time (s) ...................................: ⎯
A.3 Hot flaming oil test (see 4.6.2) N/A

TRF No.: IECEN60950_1B


Page 27 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

A.3.1 Mounting of samples N/A


A.3.2 Test procedure N/A
A.3.3 Compliance criterion N/A

B ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see 4.7.2.2 and N/A
5.3.2)
B.1 General requirements The EUT is not such equipment N/A
Position .............................................................. : ⎯
Manufacturer ...................................................... : ⎯
Type ................................................................... : ⎯
Rated values ..................................................... : ⎯
B.2 Test conditions N/A
B.3 Maximum temperatures N/A
B.4 Running overload test N/A
B.5 Locked-rotor overload test N/A
Test duration (days) ........................................... : ⎯
Electric strength test: test voltage (V) ................ : ⎯
B.6 Running overload test for d.c. motors in N/A
secondary circuits
B.7 Locked-rotor overload test for d.c. motors in secondary circuits N/A
B.7.1 Test procedure N/A
B.7.2 Alternative test procedure; test time (h).............. : N/A
B.7.3 Electric strength test N/A
B.8 Test for motors with capacitors N/A
B.9 Test for three-phase motors N/A
B.10 Test for series motors N/A
Operating voltage (V) ......................................... : ⎯

C ANNEX C, TRANSFORMERS (see 1.5.4 and 5.3.3) N/A


Position .............................................................. : No such device within the EUT ⎯
Manufacturer ...................................................... : ⎯
Type ................................................................... : ⎯

TRF No.: IECEN60950_1B


Page 28 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

Rated values ..................................................... : ⎯


Method of protection ........................................... : ⎯
C.1 Overload test N/A
C.2 Insulation N/A
Protection from displacement of windings .......... : N/A

D ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS N/A


D.1 Measuring instrument N/A
D.2 Alternative measuring instrument N/A

E ANNEX E, TEMPERATURE RISE OF A WINDING N/A

F ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES N/A


(see 2.10)

G ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM N/A


CLEARANCES
G.1 Summary of the procedure for determining N/A
minimum clearances
G.2 Determination of mains transient voltage (V)...... : N/A
G.2.1 AC mains supply N/A
G.2.2 DC mains supply N/A
G.3 Determination of telecommunication network N/A
transient voltage (V) ............................................ :
G.4 Determination of required withstand voltage (V). : N/A
G.5 Measurement of transient levels (V) ................... : N/A
G.6 Determination of minimum clearances................ : N/A

H ANNEX H, IONIZING RADIATION (see 4.3.13) N/A

J ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6) N/A


Metal used .......................................................... : ⎯

TRF No.: IECEN60950_1B


Page 29 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

K ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.7) N/A


K.1 Making and breaking capacity No such component within the N/A
EUT
K.2 Thermostat reliability; operating voltage (V) ....... : N/A
K.3 Thermostat endurance test; operating voltage N/A
(V) ..................................................................... :
K.4 Temperature limiter endurance; operating voltage N/A
(V) ....................................................................... :
K.5 Thermal cut-out reliability N/A
K.6 Stability of operation N/A

L ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL P


BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.1)
L.1 Typewriters N/A
L.2 Adding machines and cash registers N/A
L.3 Erasers N/A
L.4 Pencil sharpeners N/A
L.5 Duplicators and copy machines N/A
L.6 Motor-operated files N/A
L.7 Other business equipment Max. normal load P

M ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1) N/A


M.1 Introduction N/A
M.2 Method A N/A
M.3 Method B N/A
M.3.1 Ringing signal N/A
M.3.1.1 Frequency (Hz) .................................................. : ⎯
M.3.1.2 Voltage (V) ......................................................... : ⎯
M.3.1.3 Cadence; time (s), voltage (V) ........................... : ⎯
M.3.1.4 Single fault current (mA) ..................................... : ⎯
M.3.2 Tripping device and monitoring voltage .............. : N/A
M.3.2.1 Conditions for use of a tripping device or a N/A
monitoring voltage

TRF No.: IECEN60950_1B


Page 30 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

M.3.2.2 Tripping device N/A


M.3.2.3 Monitoring voltage (V)......................................... : N/A

N ANNEX N, IMPULSE TEST GENERATORS (see 2.10.3.4, 6.2.2.1, 7.3.2 and N/A
clause G.5)
N.1 ITU-T impulse test generators N/A
N.2 IEC 60065 impulse test generator N/A

P ANNEX P, NORMATIVE REFERENCES P

Q ANNEX Q, BIBLIOGRAPHY P

R ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL N/A


PROGRAMMES
R.1 Minimum separation distances for unpopulated N/A
coated printed boards (see 2.10.6)
R.2 Reduced clearances (see 2.10.3) N/A

S ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3) N/A


S.1 Test equipment N/A
S.2 Test procedure N/A
S.3 Examples of waveforms during impulse testing N/A

T ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER N/A


(see 1.1.2)
Separate test report ⎯

U ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED N/A


INSULATION (see 2.10.5.4)
Separate test report ⎯

TRF No.: IECEN60950_1B


Page 31 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

V ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1) N/A


V.1 Introduction The EUT is Class III equipment N/A
V.2 TN power distribution systems N/A
V.3 TT power distribution systems N/A
V.4 IT power distribution systems N/A

W ANNEX W, SUMMATION OF TOUCH CURRENTS N/A


W.1 Touch current from electronic circuits N/A
W.1.2 Earthed circuits N/A
W.2 Interconnection of several equipments N/A
W.2.1 Isolation N/A
W.2.2 Common return, isolated from earth N/A
W.2.3 Common return, connected to protective earth N/A

X ANNEX X, MAXIMUM HEATING EFFECT IN TRANSRORMER TESTS N/A


(see clause C.1)
X.1 Determination of maximum input current N/A
X.2 Overload test procedure N/A

Y ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3) N/A


Y.1 Test apparatus ................................................... : N/A
Y.2 Mounting of test samples ................................... : N/A
Y.3 Carbon-arc light-exposure apparatus ................ : N/A
Y.4 Xenon-arc light exposure apparatus .................. : N/A

TRF No.: IECEN60950_1B


Page 32 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

CENELEC COMMON MODIFICATIONS [C],


SPECIAL NATIONAL CONDITIONS [S] AND A-DEVIATIONS (NATIONAL DEVIATIONS) [A]
(EN 60950-1:2001+A11:2004, Annex ZB and Annex ZC)

General C: Delete all the "country" notes in the reference Considered P


document according to the following list:
1.1.5 Note 2 1.5.8 Note 2 1.6.1 Note
1.7.2 Note 4 1.7.12 Note 2 2.6 Note
2.2.3 Note 2.2.4 Note 2.3.2 Note 2, 7, 8
2.3.3 Note 1, 2 2.3.4 Note 2,3 2.7.1 Note
2.10.3.1 Note 4 3.2.1.1 Note 3.2.3 Note 1, 2
3.2.5.1 Note 2 4.3.6 Note 1,2 4.7.2.2 Note
4.7.3.1 Note 2 6.1.2.1 Note 6.1.2.2 Note
6.2.2 Note 6.2.2.1 Note 2 6.2.2.2 Note
7 Note 4 7.1 Note
G2.1 Note 1, 2 Annex H Note 2

1.2.4.1 S (DK): In Denmark, certain types of Class I The EUT is Class III equipment N/A
appliances (see 3.2.1.1) may be provided with a
plug not establishing earthing conditions when
inserted into Danish socket-outlets.
1.5.1 A (CH): The following is added: No such device within the EUT N/A
Switzerland (Ordinance on environmentally
hazardous substances SR 814.013, Annex 3.2,
Mercury):
NOTE- In Switzerland, switches containing
mercury such as thermostats, relays and level
controllers are not allowed.
A (SE): The following is added: No such device within the EUT N/A
Sweden (Ordinance (1990:944)
NOTE- In Sweden, switches containing mercury
such as thermostats, relays and level controllers
are not allowed.

TRF No.: IECEN60950_1B


Page 33 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

1.5.8 S (NO): In Norway, due to the IT power system The EUT is Class III equipment N/A
used (see annex V, Fig. V.7), capacitors are
required to be rated for the applicable line-to-line
voltage (230 V).
1.7.2 A (DK): Denmark (Heavy Current Regulations) The EUT is Class III equipment N/A
Supply cords of CLASS I EQUIPMENT, which is
delivered without a plug, must be provided with a
visible tag with the following text:
Vigtigt!
Lederen med grøn/gul isolation må kun tilsluttes
en klemme mærket

eller
If essential for the safety of the equipment, the
tag must in addition be provided with a diagram
which shows the connection of the other
conductors, or be provided with the following text:
"For tilslutning af de øvrige ledere, se
medfølgende instalationsvejledning."
S (FI): In Finland, CLASS I PLUGGABLE The EUT is Class III equipment N/A
EQUIPMENT TYPE A intended for connection to
other equipment or a network shall, if safety
relies on connection to protective earth or if surge
suppressors are connected between the network
terminals and accessible parts, have a marking
stating that the equipment must be connected to
an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follows:
"Laite on liitettävä suojamaadoituskoskettimilla
varustettuun pistorasiaan"
S (NO): In Norway, CLASS I PLUGGABLE The EUT is Class III equipment N/A
EQUIPMENT TYPE A intended for connection to
other equipment or a network shall, if safety
relies on connection to protective earth or if surge
suppressors are connected between the network
terminals and accessible parts, have a marking
stating that the equipment must be connected to
an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follows:
"Apparatet må tilkoples jordet stikkontakt"

TRF No.: IECEN60950_1B


Page 34 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

S (SE): The following is added: The EUT is Class III equipment N/A
NOTE- In Sweden, CLASS I PLUGGABLE
EQUIPMENT TYPE A intended for connection to
other equipment or a network shall, if safety
relies on connection to protective earth or if surge
suppressors are connected between the network
terminals and accessible parts, have a marking
stating that the equipment must be connected to
an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follows:
"Apparaten skall anslutas till jordat uttag"
1.7.5 A (DK): Denmark (Heavy Current Regulations) The EUT is Class III equipment N/A
CLASS II EQUIPMENT shall not be fitted with
socket-outlets for providing power to other
equipment.
S (DK): In Denmark, socket-outlets for providing N/A
power to other equipment shall be in accordance
with the Heavy Current Regulations, Section 107-
2-D1, Standard Sheet DK 1-3a, DK 1-5a or DK 1-
7a, when used on Class I equipment. For
STATIONARY EQUIPMENT the socket-outlet
shall be in accordance with Standard Sheet DK
1-1b or DK 1-5a.
1.7.12 A (DE): Germany (Gesetz über techische N/A
Arbeitsmittel (Gerätesicherheitsgesetz) [Law on
technical labour equipment {Equipment safety
law}], of 23rd October 1992, Article 3, 3rd
paragraph, 2nd sentence, together with the
"Allgemeine Verwaltungsvorschrift zur
Durchführung des Zweiten Abschnitts des
Gerätesicherheitsgesetzes" [General
administrative regulation on the execution of the
Second Section of the Equipment safety law], of
10th January 1996, article 2, 4th paragraph, item
2).
Directions for use with rules to prevent certain
hazards for (among others) maintenance of the
technical labour equipment, also for imported
technical labour equipment shall be written in the
German language.
NOTE Of this requirement, rules for use even
only by service personnel are not exempted.

TRF No.: IECEN60950_1B


Page 35 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

1.7.15 A (CH): Switzerland (Ordinance on P


environmentally hazardous substances SR
814.013):
Annex 4.10 of SR 814.013 applies for batteries.
2.2.4 S (NO): In Norway, requirements according to N/A
this annex, 1.7.2 and 6.1.2.1 apply.
2.3.2 S (NO): In Norway, requirements according to N/A
this annex, 6.1.2.1 apply.
2.3.3 S (NO): In Norway, requirements according to N/A
this annex, 1.7.2 and 6.1.2.1 apply.
2.3.4 S (NO): In Norway, requirements according to N/A
this annex, 1.7.2 and 6.1.2.1 apply.
2.6.3.3 S (GB): In the United Kingdom, the current N/A
rating of the circuit shall be taken as 13 A, not 16
A.

TRF No.: IECEN60950_1B


Page 36 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

2.7.1 C: Replace the subclause as follows: The EUT is Class III equipment N/A
Basic requirements
To protect against excessive current, short-
circuits and earth faults in PRIMARY CIRCUITS,
protective devices shall be included either as
integral parts of the equipment or as parts of the
building installation, subject to the following, a),
b) and c):
a) except as detailed in b) and c), protective
devices necessary to comply with the
requirements of 5.3 shall be included as
parts of the equipment;
b) for components in series with the mains input
to the equipment such as the supply cord,
appliance coupler, r.f.i. filter and switch,
short-circuit and earth fault protection may be
provided by protective devices in the building
installation;
c) it is permitted for PLUGGABLE EQUIPMENT
TYPE B or PERMANENTLY CONNECTED
EQUIPMENT, to rely on dedicated
overcurrent and short-circuit protection in the
building installation, provided that the means
of protection, e.g. fuses or circuit breakers, is
fully specified in the installation instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for PLUGGABLE EQUIPMENT
TYPE A the building installation shall be
regarded as providing protection in accordance
with the rating of the wall socket outlet.
S (GB): In the United Kingdom, to protect The EUT is not direct plug-in N/A
against excessive currents and short-circuits in equipment
the PRIMARY CIRCUIT OF DIRECT PLUG-IN
EQUIPMENT, protective device shall be included
as integral parts of the DIRECT PLUG-IN
EQUIPMENT.
2.7.2 C: This subclause has been declared 'void'. N/A
2.10.2 C: Replace in the first line "(see also 1.4.7)" by N/A
"(see also 1.4.8)".

TRF No.: IECEN60950_1B


Page 37 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

2.10.3.1 S (NO): In Norway, due to the IT power N/A


distribution system used (see annex V, Fig. V.7),
the A.C. MAINS SUPPLY voltage is considered to be
equal to the line-to-line voltage and will remain at
230 V in case of a single earth fault.
3.2.1.1 S (CH): In Switzerland, supply cords of The EUT is Class III equipment N/A
equipment having a RATED CURRENT not
exceeding 10 A shall be provided with a plug
complying with SEV 1011 or IEC 60884-1 and
one of the following dimension sheets:
SEV 6532-2.1991, Plug type 15, 3P+N+PE 250/400 V, 10 A
SEV 6533-2.1991, Plug type 11, L+N 250 V, 10 A
SEV 6534-2.1991, Plug type 12, L+N+PE 250 V, 10 A

In general, EN 60309 applies for plugs for


currents exceeding 10A. However, a 16 A plug
and socket-outlet system is being introduced in
Switzerland, the plugs of which are according to
the following dimension sheets, published in
February 1998:
SEV 5932-2.1998, Plug type 25, 3L+N+PE 230/400 V, 16 A
SEV 5933-2.1998, Plug type 21, L+N 250 V, 16 A
SEV 5934-2.1998, Plug type 23, L+N+PE 250 V, 16 A

S (DK): In Denmark, supply cords of single- The EUT is Class III equipment N/A
phase equipment having a rated current not
exceeding 13 A shall be provided with a plug
according to the Heavy Current
Regulations,Section 107-2-D1.
CLASS I EQUIPMENT provided with socket-
outlets with earth contacts or which are intended
to be used in locations where protection against
indirect contact is required according to the
wiring rules shall be provided with a plug in
accordance with standard sheet DK 2-1a or DK
2-5a.
If poly-phase equipment and single-phase
equipment having a RATED CURRENT
exceeding 13 A is provided with a supply cord
with a plug, this plug shall be in accordance with
the Heavy Current Regulations, Section 107-2-
D1 or EN 60309-2.

TRF No.: IECEN60950_1B


Page 38 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

S (ES): In Spain, supply cords of single-phase The EUT is Class III equipment N/A
equipment having a rated current not exceeding
10 A shall be provided with a plug according to
UNE 20315:1994.
Supply cords of single-phase equipment having a
rated current not exceeding 2,5 A shall be
provided with a plug according to
UNE-EN 50075:1993.
CLASS I EQUIPMENT provided with socket-
outlets with earth contacts or which are intended
to be used in locations where protection against
indirect contact is required according to the
wiring rules, shall be provided with a plug in
accordance with standard UNE 20315:1994.
If poly-phase equipment is provided with a supply
cord with a plug, this plug shall be in accordance
with UNE-EN 60309-2.
S (GB): In the United Kingdom, apparatus The EUT is Class III equipment N/A
which is fitted with a flexible cable or cord and is
designed to be connected to a mains socket
conforming to BS 1363 by means of that flexible
cable or cord and plug, shall be fitted with a
'standard plug' in accordance with Statutory
Instrument 1768:1994 – The Plugs and Socket
etc. (Safety) Regulations 1994, unless exempted
by those regulations.
NOTE – 'Standard plug' is defined in
SI 1768:1994 and essentially means an
approved plug conforming to BS 1363 or an
approved conversion plug.
S (IE): In Ireland, apparatus which is fitted with a The EUT is Class III equipment N/A
flexible cable or cord and is designed to be
connected to a mains socket conforming to I.S.
411 by means of that flexible cable or cord and
plug, shall be fitted with a 13 A plug in
accordance with Statutory Instrument 525:1997 –
National Standards Authority of Ireland (section
28) (13 A Plugs and Conversion Adaptors for
Domestic Use) Regulations 1997.
3.2.3 C: Delete Note 1 and in Table 3A, delete the N/A
conduit sizes in parentheses.

TRF No.: IECEN60950_1B


Page 39 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

3.2.5.1 C: Replace N/A


"60245 IEC 53" by "H05 RR-F";
"60227 IEC 52" by "H03 VV-F or H03 VVH2-F";
"60227 IEC 53" by "H05 VV-F or H05 VVH2-F2".
In Table 3B, replace the first four lines by the
following:
Up to and including 6 0,751)
Over 6 up to and including 10 (0,75)2) 1,0
Over 10 up to and including 16 (1,0)3) 1,5
In the Conditions applicable to Table 3B delete
the words "in some countries" in condition 1).
In Note 1, applicable to Table 3B, delete the
second sentence.
S (GB): In the United Kingdom, a power supply N/A
cord with conductor of 1,25 mm2 is allowed for
equipment with a rated current over 10 A and up
to and including 13 A.
3.3.4 C: In Table 3D, delete the fourth line: conductor N/A
sizes for 10 to 13A, and replace with the
following:
Over 10 up to and including 16 1,5 to 2,5 1,5 to 4

Delete the fifth line: conductor sizes for 13 to


16 A.
S (GB): In the United Kingdom, the range of N/A
conductor sizes of flexible cords to be accepted
by terminals for equipment with a RATED CURRENT
of over 10 A up to and including 13 A is:
- 1,25 mm2 to 1,5 mm2 nominal cross-sectional
area.
4.3.6 S (GB): In the United Kingdom, the torque test The EUT is not direct plug-in N/A
is performed using a socket outlet complying with equipment
BS 1363 and the plug part of DIRECT PLUG-IN
EQUIPMENT shall be assessed to BS 1363: Part
1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12, 12.16 and
12.17, except that the test of 12.17 is performed
at not less than 125 °C.

TRF No.: IECEN60950_1B


Page 40 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

S (IE): In Ireland, DIRECT PLUG-IN The EUT is not direct plug-in N/A
EQUIPMENT is known as plug similar devices. equipment
Such devices shall comply with Statutory
Instrument 526:1997 – National Standards
Authority of Ireland (Section 28) (Electrical plugs,
plug similar devices and sockets for domestic
use) Regulations, 1997.
4.3.13.6 C: Add the following note: N/A
NOTE Attention is drawn to 1999/519/EC:
Council Recommendation on the limitation of
exposure of the general public to electromagnetic
fields 0 Hz to 300 GHz. Standards taking into
account this recommendation are currently under
development.
6.1.2.1 S (FI, NO): Add the following text between the No TNV circuits within the EUT N/A
first and second paragraph:
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
- one layer having a distance through insulation
of at least 0,4 mm, which shall pass the electric
strength test below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that CLEARANCES
AND CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below
and in addition
- passes the tests and inspection criteria of
2.10.8 with an electric strength test of 1,5 kV
multiplied by 1,6 (the electric strength test of
2.10.7 shall be performed using 1,5 kV), and
- is subject to ROUTINGE TESTING for electric
strength during manufacturing, using a test
voltage of 1,5 kV.
It is permitted to bridge this insulation with a
capacitor complying with EN 132400:1994,
subclass Y2.

TRF No.: IECEN60950_1B


Page 41 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

(cont.) A capacitor classified Y3 according to N/A


EN 132400:1994, may bridge this insulation
under the following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by
EN 132400, which in addition to the Y3 testing, is
tested with an impulse test of 2,5 kV defined in
EN 60950-1:2001, 6.2.2.1;
- the additional testing shall be performed on all
the test specimens as described in EN 132400;
- the impulse test of 2,5 kV is to be performed
before the endurance test in EN 132400, in the
sequence of tests as described in EN 132400.
S (SE): the following text is added: No TNV circuits within the EUT N/A
NOTE – In Sweden the following text is added
between the first and second paragraph:
In Sweden, If this insulation is solid, including
insulation forming part of a component, it shall at
least consist of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
- one layer having a distance through insulation
of at least 0,4 mm, which shall pass the electric
strength test below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that CLEARANCES
AND CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below
and in addition
- passes the tests and inspection criteria of IEC
60950-1, 2.10.8 with an electric strength test of
1,5 kV multiplied by 1,6 (the electric strength test
of IEC 60950-1, 2.10.7 shall be performed using
1,5 kV), and
- is subject to ROUTINGE TESTING for electric
strength during manufacturing, using a test
voltage of 1,5 kV.

TRF No.: IECEN60950_1B


Page 42 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

(cont.) It is permitted to bridge this insulation with a N/A


capacitor complying with IEC 60384-14:1993,
subclass Y2.
A capacitor classified Y3 according to
IEC 60384-14, may bridge this insulation under
the following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by
IEC 60384-14, which in addition to the Y3 testing,
is tested with an impulse test of 2,5 kV defined in
IEC 60950-1:2001, 6.2.2.1;
- the additional testing shall be performed on all
the test specimens as described in IEC 60384-
14;
- the impulse test of 2,5 kV is to be performed
before the Endurance Test in IEC 60384-14, in
the sequence of tests as described in IEC 60384-
14.
6.1.2.2 S (FI, NO, SE): The exclusions are applicable for No TNV circuits within the EUT N/A
PERMANENTLY CONNECTED EQUIPMENT
and PLUGGABLE EQUIPMENT TYPE B and
equipment intended to be used in a
RESTRICTED ACCESS LOCATION where
equipotential bonding has been applied, e.g. in a
telecommunication centre, and which has
provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR and is
provided with instructions for the installation of
that conductor by a service person.
7.1 S (FI, NO, SE): Requirements according to this N/A
annex, 6.1.2.1 and 6.1.2.2 apply with the term
TELECOMMUNICATION NETWORK in 6.1.2
being replaced by the term CABLE
DISTRIBUTION SYSTEM.
G.2.1 S (NO): In Norway, Due to the IT power N/A
distribution system used (see annex V, Figure
V.7), the A.C. MAINS SUPPLY voltage is
considered to be equal to the line-to-line voltage,
and will remain at 230 V in case of a single earth
fault.

TRF No.: IECEN60950_1B


Page 43 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

Annex H C: Replace the last paragraph of this annex by: The EUT does not produce N/A
ionizing radiation
At any point 10 cm from the surface of the
operator access area, the dose rate shall not
exceed 1 μSv/h (0,1 mR/h) (see note). Account is
taken of the background level.
Replace the notes as follows:
NOTE These values appear in Directive
96/29/Euratom.
Delete Note 2.
Annex P C: Replace the text of this annex by: P
See annex ZA.
Annex Q C: Replace the title of IEC 61032 by "Protection of persons and equipment by P
enclosures – Probes for verification".
Add the following notes for the standards indicated:
IEC 60127 NOTE Harmonized as EN 60127 (Series) (not modified)
IEC 60269-2-1 NOTE Harmonized as HD 630.2.1 S4:2000 (modified)
IEC 60529 NOTE Harmonized as EN 60529:1991 (not modified)
IEC 61032 NOTE Harmonized as EN 61032:1998 (not modified)
IEC 61140 NOTE Harmonized as EN 61140:2001 (not modified)
ITU-T Recommendation K.31 NOTE in Europe, the suggested document is EN 50083-1.

TRF No.: IECEN60950_1B


Page 44 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

Annex ZA C: NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH P


THEIR RELEVANT EUROPEAN PUBLICATIONS
This European Standard incorporates, by dated or undated reference, provisions
from other publications. These normative references are cited at the appropriate
places in the text and the publications are listed hereafter. For dated references,
subsequent amendments to or revisions of any of these publications apply to this
European Standard only when incorporated in it by amendment or revision. For
undated references, the latest edition of the publication referred to applies
(including amendments).
NOTE When an international publication has been modified by common
modifications, indicated by (mod), the relevant EN/HD applies.
Publication Year Title EN/HD Year
IEC 60050-151 ⎯ International Electrotechnical Vocabulary ⎯ ⎯
Chapter 151: Electrical and magnetic
devices
IEC 60050-195 ⎯ International Electrotechnical Vocabulary ⎯ ⎯
Chapter 195: Earthing and protection
against electric shock
IEC 60065 (mod) 1998 Audio, video and similar electronic EN 60065 1998
apparatus – Safety requirements + corr. June 1999
IEC 60073 1996 Basic and safety principles for man- EN 60073 1996
machine interface, marking and
identification − Coding principles for
indicating devices and actuators
IEC 60085 1984 Thermal evaluation and classification of HD 566 S1 1990
electrical insulation
IEC 60112 1979 Methods for determining the comparative HD 214 S2 1980
and the proof tracking indicates of solid
insulating materials under moist
conditions
IEC 60216-4-1 1990 Guide for the determining of thermal HD 1992
endurance properties of electrical 611.4.1.S1
insulating materials − Part 4: Ageing
ovens – Section 1: Single-chamber
ovens
1)
IEC 60227 (mod) Series Polyvinyl chloride insulated cables of HD 21 Series
rated voltages up to and including
450/750V
2)
IEC 60245 (mod) Series Rubber insulated cables of rated HD 22 Series
voltages up to and including 450/750V

IEC 60309 Series Plugs, socket-outlet and couplers for EN 60309 Series
industrial purposes

TRF No.: IECEN60950_1B


Page 45 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

(cont.) IEC 60317-43 1997 Specifications for particular types of EN 60317-43 1997 P
winding wires Part 43: Aromatic
polyimide tape wrapped round copper
wire, class 240

IEC 60320 (mod) Series Appliance couplers for household and EN 60320 Series
similar general purposes
IEC 60364-3 1993 Electrical Installation of buildings − Part HD 384-3 S2 1995
(mod) 3: Assessment of general characteristics
3)
IEC 60364-4-41 1992 Electrical Installation of buildings − Part HD 384-4-41 1996
(mod) 4: Protection for safety − Chapter 41: S2
Protection against electric shock
4)
IEC 60384-14 1993 Fixed capacitors for use in electronic EN 132400
equipment − Sectional specification: +A2 1994
Fixed capacitors for radio interference +A3 1998
suppression. Selection of methods of +A4 1998
test and general requirements 2001
IEC 60417-1 ⎯ Graphical symbols for use on equipment EN 60417-1 ⎯
Part 1: Overview and application
IEC 60664-1 1992 Insulation co-ordination for equipment HD 625.1 S1 1996
(mod) within low-voltage systems − Part 1: + corr. Nov. 1996
Principles, requirements and tests
IEC 60695-2-2 1991 Fire hazard testing − Part 2: Test EN 60695-2- 1994
methods − Section 2: Needle-flame test 2
IEC 60695-2-11 2000 Part 2-11:Glowing/hot-wire based test EN 60695-2- 2001
methods – Glow-wire flammability test 11
method for end-products
IEC 60695-2-20 1995 Part 2:Glowing/hot-wire based test ⎯ ⎯
methods Section 20: Hot-wire coil
ignitability test on materials
IEC 60695-10-2 1995 Fire hazard testing − Part 10: Guidance ⎯ ⎯
and test methods for the minimization of
the effects of abnormal heat on
electrotechnical products involved in
fires − Section 2: Method for testing
products made from non-metallic
materials for resistance to heat using the
ball pressure test.
IEC 60695-11-3 2000 Part 11-3: Test flames – 500 W flames: ⎯ ⎯
Apparatus and confirmational test
methods
IEC 60695-11-4 2000 Part 11-4: Test flames – 50 W flames: ⎯ ⎯
Apparatus and confirmational test
methods
IEC 60695-11-10 1999 Part 11-10: Test flames – 50 W EN 60695- 1999
horizontal and vertical flame test 11-10
methods
IEC 60695-11-20 1999 Part 11-20: Test flames – 500 W flame EN 60695- 1999
test methods 11-20

TRF No.: IECEN60950_1B


Page 46 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

(cont.) IEC 60730-1 1999 Automatic electrical controls for EN 60730-1 2000 P
(mod) household and similar use − Part 1:
General requirements

IEC 60825-1 1993 Safety of Laser products − Part 1: EN 60825-1 1994


Equipment classification, requirements + corr. 1995
and use guide February
+ A11 1996
+corr. July 1997
IEC 60825-2 2000 Part 2: Safety of optical fibre EN 60825-2 2000
communication systems
IEC 60825-9 1999 Part 9: Compilation of maximum ⎯ ⎯
permissible exposure to incoherent
optical radition
IEC 60851-3 1996 Winding wires − Test methods − Part 3: EN 60851-3 1996
Mechanical properties
IEC 60851-5 1996 Winding wires − Test methods − Part 5: EN 60851-5 1996
Electrical properties
IEC 60851-6 1996 Methods of test for winding wires − Part EN 60851-6 1996
6: Thermal properties
IEC 60885-1 1987 Electrical test methods for electric cables ⎯ ⎯
− Part 1: Electrical tests for cables, cords
and wires up to and including 450/750V
IEC 60990 1999 Methods of measurement of touch EN 60990 1999
current and protective conductor current
IEC 61058-1 2000 Switches for appliances − Part 1: ⎯ ⎯
General requirements
IEC 61965 2000 Mechanical safety of cathode ray tubes EN 61965 2001
ISO 178 1993 Plastics – Determination of flexural EN ISO 178 1996
properties
ISO 179 Series Plastics – Determination of Charpy EN ISO 179 Series
impact Strength
ISO 180 1993 Plastics – Determination of Izod impact EN ISO 180 2000
strength
ISO 261 1998 ISO general purpose metric screw ⎯ ⎯
threads − General plan
ISO 262 1998 ISO general purpose metric screw ⎯ ⎯
threads − Selected sizes for screws,
bolts and nuts
ISO 527 Series Plastics – Determination of tensile EN ISO 527 Series
properties

ISO 3864 1984 Safety colours and safety signs ⎯ ⎯


ISO 4892 Series Plastics – Methods of exposure to EN ISO 4892 Series
laboratory light sources

ISO 7000 1989 Graphical symbols for use on equipment ⎯ ⎯


− Index and synopsis
ISO 8256 1990 Plastics – Determination of tensile- EN ISO 8256 1996
impact strength

TRF No.: IECEN60950_1B


Page 47 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

(cont.) ISO 1994 9772 Cellular plastics – Determination of ⎯ ⎯ P


horizontal burning characteristics of
small specimens subjected to a small
flame
ISO 9773 1998 Plastics – Determination of burning EN ISO 9773 1998
behaviour of thin flexible vertical
specimens in contact with a small-flame
ignition source
ITU-T 1988 Tests on power-fed repeaters using
⎯ ⎯
Recommend- solid-state devices in order to check the
ation K.17 arrangements for protection from
external interference.
ITU-T 2000 Resistibility of subscribers’ terminals to
⎯ ⎯
Recommend- overvoltages and overcurrents.
ation K.21

1) The HD 21 series is related to, but not directly equivalent with the IEC 60227 series.
2) The HD 22 series is related to, but not directly equivalent with the IEC 60245 series.
3) IEC 60364-4-41:1992 is superseded by IEC 60364-4-41:2001.
4) EN 132400, Sectional Specification: Fixed capacitors for electromagnetic interference suppression
and connection to the supply mains (Assessment level D), and its amendments are related to, but not
directly equivalent to IEC 60384-14.

TRF No.: IECEN60950_1B


Page 48 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

1.5.1 TABLE: list of critical components P


object/part No. manufacturer/ type/model technical data standard mark(s) of
trademark conformity 1)
Adaptor LINKE LK-D060080 Input: 230-240 Vac, EN 60950-1: Semko
50 Hz, 62 mA; 2001
Output: 6 Vdc, 800
mA, Class II, LPS
LCD screen (for Tpo TD024THEB2 2.36” TFT LCD Applicable parts Tested in
Monitor) screen of EN 60950-1 appliance
Lithium-ion LICO H11T19 3.7 Vdc, 1050 mA, Applicable parts Tested in
Rechargeable rechargeable, of EN 60950-1 appliance
Cell (for complies with LPS
Monitor)
-Cell SHENZHEN 523450AHR 3.7 V, 1050 mAh Applicable parts UL
BAK of EN 60950-1, recognized
BATTERY CO UL 1642
LTD
-MOSFET ANPEC 8205A 20 V, 6 A Applicable parts Tested in
of EN 60950-1 appliance
-Fuse AEM F0603HI5000 5 V, 32 A Applicable parts Tested in
V032T of EN 60950-1 appliance
-PCB SHENZHEN JSW V-0, 130 ℃ Applicable parts Tested in
CITY of EN 60950-1 appliance
JINGSIWEI
ELECTRONIC
CO LTD
Plastic Material List:
Enclosure Chi Mei PA-765 V-0, 1.5 mm thick Applicable parts UL
of IEC 60950-1, recognized
UL 94
Alt. various various Min. HB, 1.5 mm Applicable parts UL
thick of IEC 60950-1, recognized
UL 94
PCB ZHAOYUAN ZD-9*F V-0, 1.5 mm thick, Applicable parts UL
JINBAO of EN 60950-1, recognized
130 ºC
ELECTRONIC UL 94, UL 796
S CO LTD
Alt. various various Min. V-1, 105 °C Applicable parts UL
of IEC 60950-1, recognized
UL 94, UL 796
Note: An asterisk indicates a mark which assures the agreed level of surveillance.

TRF No.: IECEN60950_1B


Page 49 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

1.6.2 TABLE: electrical data (in normal conditions) P


fuse # Irated U (Vdc) P (W) I (mA) Ifuse (mA) condition/status
(mA)
— 800 6.0 4.25 709 ⎯ Max. normal load operation1)
— 800 6.0 0.78 130 ⎯ Max. normal load operation2)
Note:
1) Tested on Monitor
2) Tested on Camera

2.1.1.5 TABLE: energy hazards measurements N/A


measured max. V (Uoc) max. A (Isc) V of max. A of max. max. power bridged by
between power power test finger

supplementary information
Note:

2.1.1.7 TABLE: stored discharge on capacitors test N/A


test conditions: τ calculated (s) τ measured (s) tu → 0 (s) comments

supplementary information
Note:
1) X-Capacitor(s) installed for testing:
2) Bleeding resistor(s):

2.2.2 TABLE: hazardous voltage measurement N/A


transformer location max. voltage voltage limitation
component
Vpeak Vdc

supplementary information
Note:
Test voltage:

TRF No.: IECEN60950_1B


Page 50 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

2.2.3 TABLE: SELV voltage measurement N/A


location voltage measured (V) comments

supplementary information
Note:
Test voltage:

2.4.2 TABLE: limited current circuits measurement N/A


location voltage (V) current (mA) frequency limit (mA) Comments
(kHz)

supplementary information
Note:
1) Test voltage:
2) Rating of bridging components:

2.5 TABLE: limited power sources measurement P


limits measured verdict
For battery pack
According to Table 2B (normal condition)
Output voltage (Uoc) (in V) 4.2 Vdc
Output current (Isc) (in A) ≤ 8.0 A 2A P
Apparent power (S) (in VA) ≤ 21 VA (5 x Uoc) 7.1 VA P
According to Table 2B (single fault condition of U2 Pin3-6 Short)
Output voltage (Uoc) (in V) 4.2 Vdc
Output current (Isc) (in A) ≤ 8.0 A 5.8 A P
Apparent power (S) (in VA) ≤ 21 VA (5 x Uoc) 12.76 VA P
supplementary information
Note:

TRF No.: IECEN60950_1B


Page 51 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

2.6.3.4 TABLE: resistance of earthing conductors and their terminals test N/A
location resistance measured limit comments
(mΩ)
100 mΩ Test current = 25 A applied for 1
minute
100 mΩ Test current = 40 A applied for 2
minutes
location drop voltage measured limit comments
(V)
2.5 V Test current = 40 A applied for 2
minutes
supplementary information
Note:

2.10.2 TABLE: working voltage measurements N/A

Pri. pins Vrms Vpeak Vrms Vpeak Vrms Vpeak Vrms Vpeak Vrms Vpeak
Sec. pins

Note:
1) Test voltage:
2) Bold texts indicate the highest Vrms and Vpeak

TRF No.: IECEN60950_1B


Page 52 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

2.10.3 and TABLE: clearance and creepage distance measurements N/A


2.10.4
clearance cl and creepage Up U r.m.s. required cl cl required dcr
distance dcr at/of: (V) (V) (mm) (mm) dcr (mm) (mm)

supplementary information
Note:
1) FI: Functional insulation; BI: Basic insulation; SI: Supplementary insulation; RI: Reinforced insulation.

2.10.5 TABLE: distance through insulation measurements N/A


distance through insulation di at/of: Up test voltage required di di
(V) (V) (mm) (mm)

thin sheet material at/of: Up test voltage required layer(s)


(V) (V) layer(s)

supplementary information
Note:
1) FI: Functional insulation; BI: Basic insulation; SI: Supplementary insulation; RI: Reinforced insulation.

TRF No.: IECEN60950_1B


Page 53 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

4.5 TABLE: maximum temperatures P


test voltage (V) ................................: 6 Vdc Supplied by ⎯
battery
tamb1 (°C) ..........................................: 22.3 22.3 ⎯
tamb2 (°C) ..........................................: 26.8 25.9 ⎯
maximum temperature T of part/at:: T (°C) allowed Tmax (°C)

For Monitor Charge Discharge


Shielding 45.7 34.7 ⎯
U17 48.2 35.3 95.9 (105-9.1)
Panel 35.3 29.3 70.9 ( 80-9.1)
Battery pack 34.4 26.6 ⎯
Enclosure inside 38.2 31.2 For stress relief test
Enclosure outside 34.4 30.1 65.9 (75-9.1)
For Camera Charge Discharge
U4 51.4 40.9 95.9 (105-9.1)
C5 53.3 40.6 95.9 (105-9.1)
Shielding 52.6 43.4 ⎯
SW1 51.9 40.7 95.9 (105-9.1)
DC in Jack 48.2 38.8 95.9 (105-9.1)
Enclosure inside 44.7 37.8 For stress relief test
Enclosure outside 34.0 30.7 70.9 ( 80-9.1)
temperature T of winding: R1 (Ω) R2 (Ω) T (°C) allowed insulation
Tmax (°C) class
— — — — — —
supplementary information
Note:
Maximum room ambient temperature:
The equipment was submitted and evaluated for maximum manufacturer’s recommended ambient (Tmra) of
35 °C.

TRF No.: IECEN60950_1B


Page 54 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

4.5.2 TABLE: ball pressure test of thermoplastic parts N/A


allowed impression diameter (mm) ..................... : ≤ 2 mm ⎯
part test temperature impression diameter
(°C) (mm)

supplementary information
Note:

4.6.1, TABLE: enclosure openings N/A


4.6.2
location size (mm) comments

supplementary information
Note:

4.6.4 TABLE: enclosure openings in transportable equipment P


location size (mm) comments
Front Each opening measured There are several round opening provided (The
diameter approx. 1.3 mm speaker modules are considered as internal
barrier)
Rear One opening measured There is a wall hold opening provided, no
diameter approx. 7.5 mm hazards voltage inside
supplementary information
Note:

4.7 TABLE: resistance to fire P


part manufacturer of material type of material thickness flammability
(mm) class
PCB ZHAOYUAN JINBAO ZD-9*F Min. 1.5 mm V-0
ELECTRONICS CO LTD
Alt. various various Min. 1.5 mm Min. V-1
supplementary information
Note:

TRF No.: IECEN60950_1B


Page 55 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

5.1 TABLE: touch current measurements N/A


Condition Line → terminal A (mA) Neutral → terminal A limit (mA) comments
(mA)

supplementary information
Note:
1) Test voltage:
2) Y-Capacitor(s) used in the equipment:

5.2 TABLE: electric strength tests, impulse tests and voltage surge tests N/A
test voltage applied between: test voltage (V) breakdown
a.c. / d.c. Yes / No

supplementary information
Note:
1) FI: Functional insulation; BI: Basic insulation; SI: Supplementary insulation; RI: Reinforced insulation.
2) Test voltage a.c. / d.c.

TRF No.: IECEN60950_1B


Page 56 of 56 TP08100045-ETS

IEC 60950-1 / EN 60950-1


Clause Requirement – Test Result – Remark Verdict

5.3 TABLE: fault condition tests P


ambient temperature (°C) .................................... : 25 ⎯
model/type of power supply ................................ : — ⎯
manufacturer of power supply ............................. : — ⎯
rated markings of power supply .......................... : — ⎯
No. component fault test test time fuse input result
No. voltage No. current
(V) (A)
Test for Monitor
Observation: Steady state. no hazards.
Damaged: —
1 C201 S 6 Vdc 30 min. ⎯ ⎯ Temp: PCB near U11 = 96.7 ℃
Max. Voltage: —

Test for Cradle


Observation: EUT shutdown. Reverse
current flow to Battery is 0 A, no hazards.
Damaged:
2 Battery R 6 Vdc 10 min. ⎯ ⎯ Temp: —
Max. Voltage: —
Observation: EUT shutdown. Protected
by external adapter, no hazards.
Damaged:
3 C73 S 6 Vdc 10 min. ⎯ ⎯ Temp: —
Max. Voltage: —

Test for battery


Observation: Steady state. no hazards.
Damaged: —
3 Over-charge ⎯ 4.2 Vdc 7 hrs ⎯ ⎯ Temp: Cell = 25.5 ℃
Max. Voltage: —
Observation: Steady state. no hazards.
U2 pin 3-6, Damaged: —
4 S 4.2 Vdc 7 hrs ⎯ ⎯ Temp: Cell = 25.5 ℃
Over-charge Max. Voltage: —
Observation: Steady state. no hazards.
U2 pin 3-6, Damaged: —
5 S ⎯ 1 hrs ― ― Temp: Cell = 31.7 ℃
Over-charge Max. Voltage: —

supplementary information
Note:
1) S: Short-circuited; O: Open-circuited; O/L: Overloaded; B: Blocked; L: Locked; R: Reversed.
2) Observation: The observations during and after fault condition tests.
3) Damaged: Which component (components) damaged during the fault condition test.
4) Temp: The maximum temperature of relevant components.
5) Max. Voltage: The maximum accessible voltage of DC output terminal during the fault condition test.

TRF No.: IECEN60950_1B


Photos Page 1 of 11 TP08100045-ETS

Monitor
Photos Page 2 of 11 TP08100045-ETS
Photos Page 3 of 11 TP08100045-ETS
Photos Page 4 of 11 TP08100045-ETS
Photos Page 5 of 11 TP08100045-ETS

Camera
Photos Page 6 of 11 TP08100045-ETS
Photos Page 7 of 11 TP08100045-ETS
Photos Page 8 of 11 TP08100045-ETS
Photos Page 9 of 11 TP08100045-ETS
Photos Page 10 of 11 TP08100045-ETS

Battery
Photos Page 11 of 11 TP08100045-ETS