0 оценок0% нашли этот документ полезным (0 голосов)
134 просмотров1 страница
This document provides calculations to determine the number of magnesium anodes needed to provide cathodic protection for an underground steel tank over a 5-year design life. Given the tank's diameter, height, design life, anode weight, tank radius, anode capacity, and current densities for protecting steel in different materials, the calculations determine that 2.78 or rounded up to 3 magnesium anodes would be needed.
This document provides calculations to determine the number of magnesium anodes needed to provide cathodic protection for an underground steel tank over a 5-year design life. Given the tank's diameter, height, design life, anode weight, tank radius, anode capacity, and current densities for protecting steel in different materials, the calculations determine that 2.78 or rounded up to 3 magnesium anodes would be needed.
This document provides calculations to determine the number of magnesium anodes needed to provide cathodic protection for an underground steel tank over a 5-year design life. Given the tank's diameter, height, design life, anode weight, tank radius, anode capacity, and current densities for protecting steel in different materials, the calculations determine that 2.78 or rounded up to 3 magnesium anodes would be needed.
Design Data Tank diameter in , 16.22 m Tank height, h 4.264 m Design Life 5 years Weight of Anode, kg 27.3 kg Tank radius, r, 8.11 m Capacity 1230 amp hrs kg^-1 U 0.8 Current Density for protection of steel plate 0.005 I^A Current Density for protection of steel plate in concrete 0.003 Am^-2 No of anodes 2.78 Round off to 3.00