Submersible wastewater Pumping systems (SWPA) Handbook third edition. Products described in this publication can result in harm if not used with EXTREME CAUTION. Seek professional assistance if in doubt. Contact the manufacturer directly with questions and / or problems related to specific equipment, components, and accessories.
Submersible wastewater Pumping systems (SWPA) Handbook third edition. Products described in this publication can result in harm if not used with EXTREME CAUTION. Seek professional assistance if in doubt. Contact the manufacturer directly with questions and / or problems related to specific equipment, components, and accessories.
Submersible wastewater Pumping systems (SWPA) Handbook third edition. Products described in this publication can result in harm if not used with EXTREME CAUTION. Seek professional assistance if in doubt. Contact the manufacturer directly with questions and / or problems related to specific equipment, components, and accessories.
Forging the future of the submersible wastewater pump industry. Submersible Sewage Pumping Systems (SWPA) Handbook Third Edition SWPA Handbook cover 2/2/06 5:03 PM Page 1 Submersible Sewage Pumping Systems (SWPA) Handbook Third Edition Forward section 2/2/06 4:11 PM Page i Forward section 2/2/06 4:11 PM Page ii A Word of Caution The products described in this publication, like all products using electrical current, can result in harm if not used with EXTREME CAUTION and in strict accordance with man- ufacturers instructions, the National Electrical Code (NEC), local building codes and ordi- nances, and other applicable codes and ordinances. Seek professional assistance if in doubt. Contact the manufacturer directly with questions and/or problems related to specific equipment, components, and accessories. Although every effort has been made to present comprehensive information, the Submersible Wastewater Pump Association (SWPA) is not responsible for and expressly disclaims any liability for negligence and damages of any kind, whether direct, indirect, or consequential arising from the use, reference to, or reliance on this publication. NO GUARANTEES OR WARRANTIES, INCLUDING ANY EXPRESSED OR IMPLIED WAR- RANTIES OF MERCHANTABILITY OR FITNESS, are made by the Submersible Wastewater Pump Association with respect to this publication. This publication contains technical and specialized information and is intended to be used only by professionals who design, install, and operate lift stations. It is intended to be used for municipal and industrial (commercial) applications by qualified design engi- neers, professional installers, or lift station operators. This publication in NOT intended for use as a reference or guide by the individual consumer for residential purposes. Copyright 2006 Submersible Wastewater Pump Association (SWPA). iii Forward section 2/2/06 4:11 PM Page iii iv Forward section 2/2/06 4:11 PM Page iv v Submersible Sewage Pumping Systems (SWPA) Handbook Third Edition Library of Congress Cataloging in Publication Data Submersible Sewage Pumping Systems (SWPA) Handbook. Includes index. 1. Pumping stations Handbooks, manuals, etc. 2. Submersible pumps Handbooks, manuals, etc. TD725.S83 1986 628'.29 86-20056 ISBN 0-87371-085-1 1. Humes, Durward; 1928 2. Stolberg, Charles G.; 1947 This publication was developed by representative members of the Submersible Wastewater Pump Association (SWPA) to provide their opinions and guidance on the design and use of lift stations using submersible Solids Handling Pump Systems. This publication contains advisory information only and is a public service provided by SWPA. The reader is solely responsible for interpretation and use of this publication. SWPA disclaims all liability of any kind for the use, application, or adaptation of materi- al published in this Handbook. Published by the Submersible Wastewater Pump Association (SWPA) 1866 Sheridan Road, Suite 201 Highland Park, IL 60035-2545, USA Phone: 847-681-1868 FAX: 847-681-1869 Web Site: www.swpa.org Forward section 2/2/06 4:11 PM Page v vi Disclaimer All ideas, recommendations, methods, techniques, training, or subjects mentioned in this publication are for information and educational purposes only. Because of the intangi- ble and external influences that may bear on the use of these ideas and suggestions in any application and the absolute necessity for a totally integrated planning effort, the authors and publishers make no promises and accept no responsibility for the manner in which any of the information provided or contained herein may be applied, nor for the adverse effects that may result therefrom. Copyright 2005 By Submersible Wastewater Pump Association (SWPA). All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmit- ted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise without the prior written permission of the publisher. First hardbound edition, 1986 Second hardbound edition, 1997 Third Hardbound edition, 2005 The publisher offers special discounts on bulk orders of this publication and its other Technical Resources. For information, contact: Submersible Wastewater Pump Association 1866 Sheridan Road, Suite 201 Highland Park, IL 60035-2545, USA Phone: 847-681-1868 FAX: 847-681-1869 For information about the Submersible Wastewater Pump Association (SWPA) and its other Technical Resources, visit the SWPA Web Site at www.swpa.org Printed in the Unites States of America. Forward section 2/2/06 4:11 PM Page vi vii Table of Contents Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ix Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 1. Fundamentals and Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 2. Sizing the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 3. Selection of Submersible Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 4. Dry Well Submersible Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 5. Grinder Pumps and Pressure Sewers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 6. Controls for Submersible Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69 7. Variable Speed Pumping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89 8. Mechanical Controls and Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .101 9. Installation and Start-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109 10. Operation and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .119 Glossary of System Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127 Glossary of Electrical Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .133 Appendixes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141 Electrical Diagram Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .142 Electrical Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143 Electrical Formulae . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144 Electrical Conversion Formulae . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145 Hazardous Location Basics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .146 Loading: Access Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .147 Metric Equivalents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148 Friction Loss of Water in Plastic Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 SWPAs Standardized Presentation Format for Pump and Motor Characteristics 161 Standardized Pump/Motor Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .162 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .165 Forward section 2/2/06 4:11 PM Page vii viii Forward section 2/2/06 4:11 PM Page viii ix Preface This publication presents fundamentals with an emphasis on the design, construction, installation, and operation of a system of carefully integrated components (The Systems Approach). Submersible wastewater pump stations contain a number of complex, inter- dependent components that must be properly matched to each other to ensure long, sat- isfactory, and economic life. This approach assists consulting engineers, specifiers, users, and others gain a better understanding of the interaction between the pump, valves, con- trol panels, VFDs, basins, mechanical seal materials, and other components and how they interact to create a system that will insure optimum performance, minimum maintenance, and long life. This publication evolved because the members of the Submersible Wastewater Pump Association (SWPA) believed that too few specifiers, operators, and managers of munici- pal sewage systems were sufficiently familiar with submersible solids-handling pumps in lift station applications. The first edition of this publication was planned, drafted, written and re-written, and produced over a period of 30 months, in an intensive effort to make it both generic and immediately useful to its readers. The principal contributing authors were: A. Bo Andersson, Robert Brinley, Martin Dretel, John Drotar, George Holmes, Elmer Jira, David Maurer, David Runyon, Peter Worden, and Bud Zocolo. Other contributing authors included Jim Bradshaw, Tim Jansen, Ken Nicholls, Ray Rhein, and other members of SWPA. The final copy was reviewed by Wayne N. Austin, Critical Systems Incorporated, Orlando, Florida, and John W. Bottorf, Jr., P.E., Seabury-Bottorf Associates, Inc., Orlando, Florida. The Association thanks the companies who supported with time, money, and staff assistance the principal contributing authors to the first edition: The Bilco Company; Electric Specialty, Inc.; Enpo Pump Company; Flomatic Corporation; Goulds Pumps, Inc.; Hydromatic Pumps; The Marley Pump Company; Kenco Pumps, Inc.; Peabody Barnes, Inc.; Pumptron Division, Transamerica DeLaval, Inc.; and Putnam Water Guard, Inc. Durward Humes of the Association staff furnished editorial assistance and supervised production. Between 1994 and 1996, the SWPA Handbook was reviewed in its entirety; updated; and two new chapters were added one on Grinder Pumps and Pressure Sewers and the other on Variable Speed Pumping to create the second edition, published in 1997. The principal contributing authors of the second edition were R. Paul Farrell (Grinder Pumps and Pressure Sewer Chapter) and Joseph J. Jackson (Variable Speed Pumping Chapter). Other contributors to the second edition included William C. Corby, Jeff Ipser, Greg Mambourg, Wilbur Norwood, Bobby Richardson, and Perry Stephens, Jr. The Association thanks the companies who supported them with time, money, and staff assistance the principal contributing authors to the first edition: Franklin Electric Company, Reliance Electric, F. E. Myers, Yeomans Chicago Corporation, Barnes Pumps, and Goulds Pumps. The principal contributors to the third edition were Jeff Bergman, Chris Caldwell, Bob Domkowski, Steve Doolittle, Greg Hogan, Joseph Jackson, Loran Knudsvig, Mark Kowalak, and Arnie Sdano. The Association thanks the companies who supported with time, money, and staff assistance the principal contributing authors to the third edition: Danfoss Water & Wastewater, ABS Pumps, ITT Flygt Corporation, Zoeller Engineered Products, Goulds Pumps, Yeomans Chicago Corporation, SJE Rhombus, Barnes Pumps, Inc., Fairbanks Morse Pump. Charles Stolberg of the Association staff furnished editorial assistance and supervised production of the second and third editions. Forward section 2/2/06 4:11 PM Page ix x Forward section 2/2/06 4:11 PM Page x 1 Introduction The purpose of the Submersible Sewage Pumping Systems (SWPA) Handbook is to famil- iarize and assist those who are responsible for designing, installing, and operating lift sta- tions using submersible solids-handling pump systems. It was prepared by a task force of knowledgeable specialists from submersible pump and accessory manufacturer companies. The SWPA Handbook presents fundamentals. It also addresses some of the more sophis- ticated aspects of submersible pump systems and their components ... lift stations and the selection of proper equipment ... how to make certain the station is installed properly... and how to establish the operating and maintenance procedures needed to ensure long, satisfactory, and economic station life. SWPA defines solids handling pumps as those capable of handling larger than a 2-inch solid sphere (sphere size is defined as the maximum physical diameter of a non-deformable sphere that can pass through the pump without obstruction or interference of any kind from volute entry point to discharge port and categorizes them by discharge size 3-inch through larger than 12-inch). These pumps were formerly referred to as non-clog pumps. This Handbook is intended to be used as a daily reference. As a designer or specifier, it will give you background on the fundamentals and components of submersible pump- ing systems in Chapter 1 and in Chapters 2 and 3 provide detailed guidelines for sizing the system and selecting the proper pumping system. Chapter 4 discusses dry pit submersible pumps A submersible pump, originally devel- oped for use in applications where the pump unit will be submerged in the pump liquid, being used in a dry well station where the wet well is separated from the dry pump cham- ber. Chapter 5 discusses grinder pumps, a special design of submersible pump frequently used for pressurized sewage systems or in very small stations. Grinder pumps incorpo- rate a grinding mechanism to reduce sewage particulate and pump the resulting slurry to a collection system. Chapters 6 addresses controls for submersible pumps. Chapter 7 provides designers and end users with basic information about variable speed pumping and variable fre- quency drives. Chapter 8 describes mechanical controls and components including valv- ing, access doors, and slide rail assemblies. If you are responsible for installation, you'll want to concentrate on Chapter 9, which explains in detail how the entire station is to be put into place and made operational. If your responsibility is for on-going operations, study Chapter 10, which offers specif- ic guidelines on operation and maintenance procedures. To make this Handbook more useful, two glossaries are included. The first is a Glossary of System Terms. The second is a Glossary of Electrical Terms. There are also a variety of source materials, including friction loss tables for various pipe and fitting configura- tions. Finally, information on the Standardized Presentation Format for Pump and Motor Characteristics, developed by the Submersible Wastewater Pump Association (SWPA) is included. In summary, the SWPA Handbook presents the fundamentals and tells you how to use them in practice. If you are planning and designing a station, you will also need current manufacturer's literature relative to specific pump and component selection. If you are installing or maintaining a station, you will need specific equipment instructions from manufacturers. Forward section 2/2/06 4:11 PM Page xi Current information about submersible pump manufacturers and manufacturers of com- ponent parts and accessory items for submersible sewage lift stations is included in the Annual SWPA Membership Roster and Product Reference Guide A Users and Specifiers Guide to the Submersible Wastewater Pump Industry. For a complimentary copy, contact SWPA headquarters, 1866 Sheridan Road, Suite 201, Highland Park, IL 60635-2545, USA. Phone: 847-681-1868. FAX: 846-681-1869. For additional information about the Association, its services, activities, membership benefits, training programs and Technical Resources, visit the SWPA Web Site at www.swpa.org. We dedicate the SWPA Handbook to lift station designers and operators, and to the broader use of reliable, efficient, and economical submersible pumping systems. 2 Forward section 2/2/06 4:11 PM Page xii The purpose of a lift station is to receive, store temporarily as needed, and move wastewater and/or stormwater through a collection system. The two generic types of lift station designs are wet well and wet well/dry well. The latter, which was first used in North America, uses a wet well (also called a pit or tank) to collect wastewater and a com- panion dry well which contains the pump- ing, control, and related equipment. The submersible wet well lift station, widely used in Europe, is becoming wide- ly used in North America. It uses only one well as opposed to two. It is built around a submersible solids-handling pump-motor unit, which is designed to operate under water with an open submerged inlet. All system components are installed in or con- tiguous to the single wet well. More and more, submersible solids-han- dling pumps are being specified in North America. They are used primarily for wet well sewage lift stations and for industrial sump or process effluent applications. A common application for smaller sub- mersible pumps is to move effluent in sep- tic tank systems. Large and small units are used in a variety of ways in home, farm, motel, school, marine, commercial building, industrial plant, and municipal sewage and stormwater systems. Submersible pumps have proven effec- tive since their introduction, refuting those skeptics who originally wondered how an electric motor-powered pump "could run under water." Originally developed in Europe, they are now used throughout the world to pump clear water, raw water, and wastewater. Millions are in daily use. The submersible wastewater pump came to the United States about 1955. It became popular in the early 1960s, when a pump release system was developed to allow the pump to disconnect automatically from the piping and be lifted out of the well for ser- vice. This ended the dirty and sometimes dangerous task of sending personnel into the station to manually disconnect and then reconnect the pump. There are two classes of submersibles. The first, commonly called sewage ejectors, are normally used in home and light com- mercial applications. They usually handle up to 2-in. spherical solids and range from 1/3 to 3 HP. Larger submersibles, defined as han- dling greater than 2-in. solids, have a min- imum of 3-in. discharge. They are used in municipal, commercial, and industrial applications, for pumping sewage and all 3 Chapter 1 Fundamentals and Components Submersible wet well lift stations are in wide use. They offer a number of advan- tages over wet well/dry well stations. There are Very Small, Small, Medium, and Large Stations, each with its own design parameters. Special submersibles, called grinder pumps, are suitable for pressurized sewage system applications. Submersible system components include the station itself, the pump-motor units, piping, valv- ing, electrical controls, and access frames and covers. Guide rail systems are unique to submersibles. Considerations in selecting a station site are discussed. Chapter 1 2/2/06 4:18 PM Page 3 types of industrial wastewater. Wet well lift stations, using submersibles, offer the following distinct advantages over wet well/dry well stations: 1) The single, buried well reduces the space needed for excavation and installa- tion, and eliminates the need for elaborate above-ground buildings or enclosures. There is seldom a need for dehumidifiers, lighting, or other appurtenances which are normal for dry wells. The result is a sub- stantial reduction in both construction and operating costs as explained in Figure 1-1. 2) Submersible pumps are specifically designed to operate in the liquid being pumped. This eliminates pump flooding problems. 3) Guide rail systems allow service per- sonnel to remove, inspect, and service the pump (or pumps) without having to enter the wet well. This reduces the chance of accidents during servicing. 4) Other servicing is easy, since all plumbing and electrical controls are acces- sible outside the wet well. 5) Controls can be installed directly over the station or in a remote location. There is a choice of control systems, from simple liquid level controls and alarms to sophis- ticated telemetry. 6) Submersible lift stations are designed to blend readily with natural surroundings, since there is no pump house and there's a minimum of above-ground equipment. Submersible pumps operate quitely, since the working installation is below ground level, and there is a reduced chance for the accidents which can occur with an exposed motor. 7) Above all, submersible solids-handling pumps are reliable and operate efficiently. Pumps run under and are cooled by the liq- uid, thus adding to their life span. They run only when needed, reducing wear and power bills. The system is designed to elim- inate suction pipe clogging and net positive suction head problems. Fundamentals and Components 4 Figure 1-1: Wet well stations (right) take less space, use less equip- ment, and are generally less expensive to build than wet well/dry well stations. Double Well System Single Well System Chapter 1 2/2/06 4:18 PM Page 4 A Needs and Cost Comparison for wet well/dry well stations is summarized in Table 1-2. Station Classifications Submersible wastewater pumping sta- tions are usually classified by size (gallons per minute or GPM), as follows: Very Small Stations (less than 80 GPM). This type of station usually serves an indi- vidual dwelling or several isolated buildings with discharge lines smaller than 4-in. Simplex (single) pumps may be permitted, but duplex units are recommended for reli- ability and length of service. Both package and built-in-place stations are used. Small Stations (80 to 300 GPM). Duplex stations are specified almost exclusively, with each pump sized to handle the maxi- mum flow. Some locations allow 2-1/2-in. solids but most states require a minimum of 3-in. solids-handling capacity and a 4- in. discharge. Provision is often made for future growth by selecting vendors who have the same pump models available over Fundamentals and Components 5 Table 1-2 Needs And Costs Comparison for Wet/Dry Well Stations Equipment Needs And Costs Equipment Needs Wet Well/Dry Well Submersible Pump Equal Equal Electrical Controls Equal Equal Discharge Piping Equal Equal Suction Plumbing Required Not Required Ventilation System Required Not Required * Sump Pump Required Not Required Dehumidifier Required Not Required Guide Rail System Not Required Required Valve Vault Not Required Sometimes Required Installation Needs And Costs Installation Requirements Wet Well/Dry Well Submersible Wet Well Equal Equal Dry Well Required Not Required Excavation Double Single Power Wiring Equal Equal Accessory Wiring Required Not Required Discharge Piping Equal Equal Suction Piping Required Not Required Valve Vault Not Required Sometimes Required * May be required under NFPA Standard 820. Table 1-2: Comparison of equipment and installation requirements for the two types of stations. Chapter 1 2/2/06 4:18 PM Page 5 a range of impeller or horsepower sizes. This keeps expansion or con- version costs to a mini- mum on pump, control, and sump changes. Alternately, provision is made for expansion with a third pump. Both pre- fabricated and built-in- place stations are used. Medium Stations (300 to 3,000 GPM). Generally, duplex sta- tions are used. However, more consideration is now given to expand- able triplex systems which provide for future increases in pumping capacity. Each pump should be capable of handling more than the maximum design flow. Expandability is recommended, as noted under Small Stations. Discharge size diam- eter and line length become critical factors in providing for expansion. Prefabricated stations are still used in the smaller capac- ity units, but built-in-place stations domi- nate above 1,500 GPM. Large Stations (over 3,000 GPM). Two pumps can be used, but efficiency of oper- ation over varying ranges of flow usually dictates three or more pumps. Capacity should be selected so that, with the largest pump out of service, the others can handle the maximum flows. As an example, resort areas which have seasonal variations in flow often require unequal horsepower combinations, since it is less expensive to run a 40 HP pump at 100 percent load than a 75 HP pump at 55 percent load. Rectangular stations with splash baffles on the interior walls to damp- en water surge are necessary for high capacity pumps. Built-in-place, special design stations are commonly used. System Components Submersible solids-handling pump lift stations consist of: Pump-motor unit Station, also called the wet well or basin Piping Valve box, with mechanical controls Electrical panel and controls Pump removal apparatus, usually called the guide rail system Access frames and cover, both for the well and the valve box The major components of a submersible lift station are shown in Figure 1-3. A stan- dard station configuration is shown in Figure 1-4. Most lift stations are designed for multi- ple pump installation. The most common is the duplex installation, where two units alternate in operation, to equalize the wear on the pumps and to keep debris from building up in the wet well. Multi-pump installations ensure continued operation if one pump fails or is removed for servicing, and also provide extra capacity in times of extraordinary loads. There are a number of components of the installation. Pump-Motor Units Submersible wastewater pumps are ver- tical, close-coupled, extra-heavy duty units which are designed to operate in the waste- water they are pumping. Since sewage con- Fundamentals and Components 6 Figure 1-3: Major components of a submersible lift station. Electrical Plumbing Chapter 1 2/2/06 4:18 PM Page 6 tains solid material, they are designed to be non-clogging. They are commonly called submersible sewage pumps. Septic Tank Effluent Pumps (STEP) are submersible pumps used to pump the efflu- ent from septic tanks to a discharge system. They are commonly called submersible efflu- ent pumps. A grinder pump is a special design of sub- mersible frequently used for pressurized sewage systems or in very small stations (see Chapter 5). This type of pump incor- porates a hardened, stainless steel cutter designed to cut solids in the sewage into small pieces so that the slurry can be pumped under pressure through small diameter, low pressure force mains. Pressurized systems are easy to install. They normally use plastic piping, are installed just below the frost line, and are especially adaptable to hilly or rocky ter- rains. Grinder pumps (1, 1-1/2 or 2 HP) were first used to serve single or multi-family dwellings where a septic tank or gravity design could not be used, or were too expensive. Larger horsepower grinders have now been developed to service small apart- ments, motels, nursing homes, restaurants, and similar commercial developments. Fundamentals and Components 7 Figure 1-4: Configuration of a submersible lift station, with compo- nent parts in place. Some stations are pre-fabricated. Chapter 1 2/2/06 4:18 PM Page 7 They have the same advantages as small grinder systems. Discharge Size: A standard submersible solids handling pump with a 4-in. discharge will normally handle 2-in. to 3-in. spherical solids. Each manufacturer's literature spec- ifies the maximum solids size which can be handled by their particular pumps. Discharge sizes for submersibles usually range from 3-in. to 14-in., although larger sizes are available. Motors: Submersible pumps must be sized to the application. Motors are nor- mally available in 850, 1150, 1750, and 3450 RPM designs, using 60 cycle power. Horsepower ratings range from 1/2 to 1500 HP and larger. Variable speed controls are also available with the use of variable fre- quency drives (see Chapter 7). Depending on the application, motors generally operate on 115, 230 or 460 volts. Occasionally, 575 and higher voltage units are required. Motors may be single or three phase; however, single phase units are usu- ally limited to 5 HP or less. Capacities: Submersible pumps can be tailored to the capacity requirements of any particular installation. A specifier can ask for variable combinations of head and capacity as a function of the system head curve. Selection can accommodate such fac- tors as existing and future flow require- ments, discharge pipe size, materials, fix- tures, and length of sewer line. Typically, dynamic heads range from 15 to over 200 feet, and flows range from 50 to 7,000 GPM. Submersible pumps are shown in a sta- tion in Photo 1-5. Wet Well Stations Stations are available either as factory assembled (prefabricated) packages, or are built-in-place. Both types can be a combi- nation of standard components or can be custom designed. Prefabricated stations are available from several manufacturers. They are usu- ally made of coated steel, fiberglass, or pre- cast concrete. Station design should be based on both the current anticipated flow and projected future needs. The intake and discharge port levels will be dictated by the depth of set- ting of the station and the requirements of the sewage piping. The pump base plate, discharge piping, and guide rail system are usually installed at the factory. Tank diam- eters are normally four to six feet, with a maximum of 10 feet to keep within practi- cal over-the-road trucking limitations. The specifier should work closely with the pump manufacturer to determine final specifications for a prefabricated station. Built-in-place stations are usually made of concrete. The same considerations apply the final station must be designed and built to accommodate all wet pit system components. The sizing of the station and pumping equipment is covered in detail in Chapter 2. Piping and Controls The intake port of the submersible sta- tion, as discussed earlier, is located at the point where the incoming sewage line con- nects with the station. The liquid sewage flows to the bottom of the station. When the liquid level rises sufficiently, a control energizes the pump-motor unit, the sewage passes into the pump impeller, and is forced out through the discharge pipe and into the outgoing sewer line. Thus, only one section of internal piping Fundamentals and Components 8 Photo 1-5: Submersible pumps in place and working in a station. Chapter 1 2/2/06 4:18 PM Page 8 is required for each pump from the pump discharge port to the station dis- charge port. To accommodate the removal and reinsertion of each pump for servicing, the pump discharge is sealed rather than bolted permanently to the discharge piping. The plumbing valve box is normally located adjacent to the station, at ground level, for easy access. There are check and shut-off valves for control purposes. Electrical Controls The heart of the control system for sub- mersibles is the liquid level control, which turns the pump On when the liquid reach- es a set level and turns the pump Off when the liquid drops back to a low level. Duplex pumps usually alternate operation auto- matically on each successive cycle. Typically, an override control is provided which brings in the second pump when the in-flow is unusually heavy or the first pump fails to operate. Control panels are installed above ground, and usually contain: pump disconnects, across-the-line starters or contactors with overload protection, Hand-Off-Automatic (HOA) selectors, and alarm systems to indi- cate high liquid level conditions in the wet well. Alarm systems can be visual, audible, or provide remote monitoring through teleme- try devices or telephone lines. The control manufacturer will help deter- mine what controls are needed for a par- ticular application and then fabricate the control panel to this specification. All pan- els should be built in accordance with the National Electrical Code (NEC). Guide Rail System The pump removal and replacement apparatus (usually called the guide rail [or cable] system) is unique to submersible installations. It permits the pump to be removed, inspected, and serviced, and then reinserted into its operating position with no need for the service personnel to enter the station. The guide rail system is a standard com- ponent of the wet well installation. The rails, either stainless steel or galvanized pipe, are mounted in place, from the bot- tom of the station to the access cover. A bracket on the pump unit mates with the rails. During installation, the pump or pumps are lowered into place on the rail- ing and fitted to the discharge pipe by means of a quick-disconnect sealing flange. A hoist is normally used to remove the pump for inspection or servicing. It may be portable, truck-mounted, or be a permanent part of the installation. A chain or cable is attached to a bracket or to the top of the pump, the pump is lifted, and the seating flange disengages from the discharge pip- ing. The pump is then raised to the top of the station, guided by the rails. After inspec- tion or servicing, the pump is lowered back into the wet well along the rails and the sealing flange automatically re-engages the discharge piping. Access Covers Access covers or doors complete the wet pit installation. They permit visual exami- nation of the interior of the wet well, removal and reinsertion of the pump(s), and access to the valve box controls. Access covers are locked in the closed position when not in use, but may also be locked in the open position to avoid having them close accidentally when the station is being serviced. They are available in steel or aluminum, as well as with special fin- ishes for particular environments. They are Fundamentals and Components 9 Photo 1-6: Attractive lift station. Chapter 1 2/2/06 4:18 PM Page 9 also available in various sizes, styles, load- carrying capacities, and with lift springs for safe, easy manual operation. Selecting a Site Determining the best location for a pumping station (see Photos 1-6 and 1-7) begins with a comprehensive survey of the present and future needs of the area that the station will serve. The survey must con- sider how the location will affect construc- tion costs, as well as the environmental impact of the station. The survey should include a study of the topography of the land downstream from the proposed station, to determine if tun- neling through high ground or providing interceptors could produce gravity drainage, and thus eliminate the need for the station. Other factors to consider include site conditions, land ownership, site and local drainage, traffic patterns, access for vehicles, and the availability of utilities and community services such as electric power and telephone service. If the survey confirms the need for the station, it may be best to locate it some- where other than at the lowest surface ele- vation within the drainage area. For exam- ple, the survey may reveal that a remote location may be better than one in a dense- ly populated area. Good site selection results from balancing technical needs, eco- nomic factors, and environmental impact. The station must meet all local building codes, ordinances and other requirements. When specifying station size, consider the superstructure (if any), access and parking requirements, requirements for moving equipment in and out of the station, screen- ings disposal, property line clearances, and the amount of excavation needed. Make cer- tain that alarms and signals can be seen and heard. The depth of the station substructure below the ground level is determined by the depth of incoming sewers or drainage chan- nels and by foundation conditions. Surface conditions, environment, and possible flood conditions determine the type of super- structure, height of electrical controls, and the degrees of exterior finish and trim. Because odors may escape from a pumping station, proper ventilation must be part of the design. The critical wet well high level and bot- tom elevation are determined by the eleva- tion of the basement of the residence most likely to flood and the elevation of the incoming sewer. Such a determination includes the hydraulic gradient and storage capacities of the wet well and sewer sys- tem. Small lift stations are frequently built entirely underground. They can be prefab- ricated or built-in-place. When stations with superstructures must be built in densely populated areas, it is important that the station be architectural- ly compatible with the other buildings in the neighborhood. Landscaping should complement the station's surroundings. In residential areas, tall and closely planted shrubbery can buffer noise and make the station less obtrusive. In remote areas, the esthetic design is left to the discretion of the engineer. It must be consistent with erosion and sediment con- trol practices used in the area. Fencing, bur- glar alarms, and the use of few or no win- Fundamentals and Components 10 Photo 1-7: Smaller lift station. Chapter 1 2/2/06 4:18 PM Page 10 dows in any buildings can provide protec- tion against vandalism. Site Considerations Care must be taken by the installing con- tractor in setting and landscaping the lift station. The top of the station should be above grade at all times, and site grading should insure that drainage water flows away from the station. When the station is to be located in a flood-prone area, every effort should be made to relocate it. When this cannot be done, flood-tight or gas-tight access covers should be specified. They are available from specialty manufacturers. In this situation, the electrical controls must be mounted so that they will not be submerged at the high- est known flood level. In flood-prone locations, the electrical conduit entry must be completely sealed to prevent groundwater from entering the junction box from outside the station. The preferred method is to locate the control panel on a telephone pole or pedestal above the flood plain, and to make sure there are no splices in the pump or level control cables. Another site selection problem involves locating the lift station on streets, highways, or other areas subject to traffic. Every pos- sible alternative site should be considered. If this location is unavoidable, a manhole cover, rather than a fabricated cover, should be used. Since station failure can cause consider- able damage, it is important to specify dependable controls and an emergency power source for most wastewater and stormwater pumping stations. The pumping station may be provided with a means of bypassing the wet well for maintenance or for emergency conditions. For these contingencies, a manhole can be constructed just upstream of the wet well, with provision made for a temporary pump. A valved connection is then provided in the force main just downstream of the pump station. A hose can then be used to link the pump to the valved connection in the force main, to direct the flow around the pump station. During planning, long before construc- tion begins, study the subsurface conditions of the station site. Analyze the profile and physical properties of the soil to determine the proper foundation. This will also define the chemical characteristics of the soil and the groundwater conditions. Use this infor- mation on the groundwater table to design drainage and/or dewatering systems for the station site, and to evaluate station design. Qualified soil engineers are best capable of analyzing and interpreting this data for the foundation design. It is important to control the groundwa- ter levels during excavation. Inadequate or improper dewatering can lead to construc- tion problems or failures. Dewatering begins with a detailed subsurface investi- gation to determine how to design the dewatering system. Consult a qualified excavating contractor before proceeding. Fundamentals and Components 11 Chapter 1 2/2/06 4:18 PM Page 11 12 Chapter 1 2/2/06 4:18 PM Page 12 Sanitary wastewaters consist primarily of used portions of the public water supply that are discharged into sewers through the plumbing systems of buildings. They some- times include used portions of the private water supply from industrial and commer- cial establishments and residential com- munities. Before their ultimate disposal, these wastes normally are collected and transported to a plant for treatment. To provide economical and effective treatment for these objectionable waste- waters, the system must keep the volume of sanitary waste to a minimum. Wastewaters such as storm runoff from roof, yard, and foundation drains should be separated from the sanitary wastewaters and then conveyed to discharge by a sep- arate storm sewer system. Design Considerations An engineering study is necessary prior to the design and construction of any san- itary wastewater collection or transfer sys- tem. This study should analyze design peri- ods, population growth projections, land development patterns, quantity of available water, and quantity of wastewater flows. Design periods. There is a maximum hydraulic or functional capacity beyond which any wastewater system cannot oper- ate satisfactorily. The time span usually a number of years from the date of the original design to an estimated future date when the maximum capacity of the system will be reached, is referred to as a design period. The design period for any system should be determined before the start of the engi- neering design. This analysis should take into account obsolescence and the wear and tear on the equipment, the possibility of future expansion of the system, the ease or difficulty of carrying out such expan- sion, and the efficiency of system perfor- mance during its early years when it will not yet be operating at full capacity. In choosing design periods, imposing an undue financial burden on the systems present users should be avoided. Careful selection of the design period should assure that system cost will be shared equitably by both existing and future consumers. Population growth projection. The quantity of sanitary wastewater generated by a community depends on the popula- tion and the per capita wastewater contri- bution. Therefore, an accurate population projection is essential to a well-planned col- lection and treatment system. A commu- nity's population growth and distribution 13 Chapter 2 Sizing the System Considerations in sizing a municipal sewage system include a proper design peri- od, projections of population growth and land development trends, and the quan- tity of available water and its consumption rate. Factors in sizing stations include average daily flow, maximum and minimum daily flows, and peak hourly flow. With residential stations, designers have the choice of grinder, Septic Tank Effluent Pump (STEP), or solids-handling systems. For larger systems, different sizing approaches are explained. Chapter 2 2/2/06 4:29 PM Page 13 may be affected by employment opportu- nities, commuting distances for workers, socio-economic factors, zoning, availability of community facilities and services, etc. There are, however, other influences that may not be evident at the time of the study but that may emerge later to cause a major shift in population growth. Examples might be a new discovery of available natural resources in the vicinity or an industry's decision to locate in the community. Details of population projection methods are discussed in many textbooks and ref- erences. Most of the graphical or mathe- matical projections are based on the exten- sion of the past trend of growth. These methods are most applicable to communi- ties of stable growth. For young and fast growing communities, or communities with high growth potential, a meaningful projection requires good historical data coupled with a study of all related envi- ronmental determinants and the best pos- sible engineering judgment. In addition, population projections often can be obtained from previous studies. Earlier construction grant applications usu- ally contain population projections for the community. Studies for larger basin areas will require further analysis to apply their results to a specific community. Environmental Protection Agency (EPA)- funded projects for wastewater treatment plant construction require that, for compar- ison purposes, federal population projections be adjusted to cover only the study area. Land development. Local and regional land-use planning, development of urban renewal projects, and zoning regulations will influence the future population distri- bution. These, in turn, affect the quantity of wastewater to be removed from a com- munity. Recent trends in construction of multi-dwelling apartments, condominiums, and townhouses have affected local densi- ties and thus the quantity of wastewater produced. Many housing units especially newer ones often are equipped with appliances such as dishwashers, garbage disposal units, clothes washers, etc. that increase the water consumption as well as the amount of sanitary wastewater generated; therefore, the age of housing units also must be considered. Quantity of available water. The quan- tity of wastewater flow hinges mainly on the quantity of available water and its con- sumption rate. The general public's ten- dency to use water depends on whether the water supply is metered, the cost of the water, and the availability of public sewers. Because wastewater consists primarily of used water, the water consumption per capita should be established. Then the quantity of water reaching the sewer line can be estimated. Fluctuation in water demand by peak hours or even by season also plays an important role in the design of sewage systems and hence in the capac- ity requirements for pumping stations. Quantity of wastewater flow. The quantity of flow varies continuously in a wastewater system. In any system where sanitary wastewater is the major contribu- tor to the total flow, there will be a wide and perhaps an hourly fluctuation. If wastewater works are not designed to accommodate this, flow variation can cause operational problems in collection systems as well as in treatment facilities. Approach To Sizing Generally, in sizing a lift station, engi- neers study the average daily flow, maxi- mum and minimum daily flows, and peak hourly flow. Peak hourly flows and mini- mum daily flows are used to evaluate the sewer system and conduits in treatment works. The maximum daily flow dictates the size of flow equalization facilities, and the sizing of wet wells and pumping equip- ment. The average daily flow helps to ana- lyze the performance of a plant's treatment units. (Special sizing considerations may be required and will be discussed later in this chapter.) To make calculations using these design criteria to size a sewage lift station for a city, municipality, or town, information is needed on the number of persons being Sizing the System 14 Chapter 2 2/2/06 4:29 PM Page 14 served and the water consumption per capita per 24-hour day. The flow chart shown in Figure 2-1 is typical of the flow from a given town or city, and will be used simply as an example for our calculations. Actually, the change in flow during a 24-hour period the mini- mum and maximum and their duration will differ depending on location and type of environment. The important point is that if the city or town can present a reason- ably accurate flow chart, a submersible lift station can be designed to do the job in an efficient and economical manner. This particular diagram shows that dur- ing the 24-hour period, the waste con- sumption has three peaks: 1. Morning 6:00 a.m. - 8:00 a.m. 2. Noon 11:30 a.m. - 1:30 p.m. 3. Evening 5:00 p.m. - 9:00 p.m. The evening peak is the highest and shows that approximately 60 percent of the total water consumption is concentrated in this four-hour period. The station should be sized according to the inflow during this peak period: Qin = 60% of 24-hr. flow in gallons = GPM the 4-hr. period in minutes Qin = .60 x n x f = GPM 4 x 60 Where: Qin = inflow to the station in GPM n = number of persons being served f = water consumption in gallons per capita per 24-hour day .60 = 60% as shown in Figure 2-1. For design purposes, it is necessary to use existing conditions to estimate future wastewater flows. If the system has no flow records or if a complex sewer network makes measurement impractical, design flows may be determined by estimating and totaling flows from the various con- tributors. Or the flow may be calculated as a percentage of the total available water supply. Sizing the System 15 Figure 2-1: Sewage flow pattern in a typical city or town. Chapter 2 2/2/06 4:29 PM Page 15 Careful study is needed, however, to pro- ject wastewater flow. Average flows may vary from 50 to 210 gallons per capita per day (gpcd). Weather conditions, water use habits, access to public sewers, water and sewer cost rates, adequacy of water supply, and the economic condition of the com- munity all contribute to this wide variation in per capita flow. In addition to domestic wastewater flows, contributions may come from com- mercial, industrial, institutional, and infil- tration/ inflow sources. Residential Stations The residential lift station can use either a simplex or duplex grinder, Septic Tank Effluent Pump (STEP), or solids-handling pump system. All three can pump into gravity sewers or pressurized systems. The pipe size of the pressurized system will be dependent on the type of system that is used. For example, the grinder and STEP system could be smaller because these sys- tems will be pumping smaller solids that the solids-handling pump system. There are a number of advantages to pressure sewers. Because they use small- diameter plastic pipe buried just below the frost penetration depth, their installation cost in low-density areas can be quite low compared to conventional gravity systems. Other site conditions that enhance this cost differential include hilly terrain, rock out- cropping, and high water tables. Because pressure sewers are sealed con- duits, there should be no opportunity for infiltration. Treatment plants can then be designed to handle only the domestic sewage generated in the homes serviced, which reduces the cost of processing the infiltration that occurs in most gravity systems. As with any technology, there are also certain disadvantages. For pressure sewers, these include added operation and mainte- nance costs because of the need for mechanical equipment at each point of entry to the system. In addition, the waste- water conveyed through the treatment facil- ity may be more concentrated than normal. Essentially, a pressure sewer system is the reverse of a water distribution system. Where the latter employs a single inlet Sizing the System 16 Figure 2-2: Grinder/solids-handling pump system. Chapter 2 2/2/06 4:29 PM Page 16 pressurization point and a number of user outlets, the pressure sewer embodies a number of pressurized inlet points and a single outlet. The input to the pressure main follows a generally direct route to a treatment facility or a gravity sewer, depending on the application; the primary purpose of this type of design is to mini- mize the time that sewage is retained in the sewer. Illustrated are the grinder or solids-han- dling pump system (Figure 2-2) and the STEP system (Figure 2-3). Tank diameters for simplex grinder and solids-handling pumps are generally limit- ed to 24 to 30 inches, while depths are reg- ulated by soil conditions and/or site eleva- tions. The general practice is to provide one tank per home, but sometimes two and even three homes will be connected to a single tank. The problem is not so much whether the system can handle the addi- tional load as the logistics of connecting piping from several homes. The grinder unit reserve capacity is shown in Figure 2-4 as the volume avail- able for storage between the On level switch and the in-flow. Several states have established standards for reserve storage capacity; with a simplex grinder pump, this volume is usually 50 gallons. Consult the appropriate authorities in your area for applicable local and/or state standards. The STEP system features a fractional horsepower sewage/effluent pump operat- ing in conjunction with a septic tank. There are various designs, ranging from use of the existing septic tank with a new efflu- ent tank (Figure 2-5) to a single tank sys- tem in either concrete or fiberglass (Figure 2-6). Septic tanks generally have about 100 to 200 gallons of residual capacity due to the free board (septic storage) inherent in their construction. Small, solids-handling pumps for resi- dential use are normally fractional to 3 HP in size. They normally use single phase, 115 or 230-volt motors, and are designed to pass up to 2-in. solids. Like the STEP pump, they operate at 1750 RPM and can be made of cast iron, bronze, and/or plas- tic. Unlike effluent pumps, they have a solids-handling impeller and volute. Medium Stations Very small, small and medium-sized sub- mersible lift stations incorporate one to three solids-handling sewage pumps with capacities up to 3,000 GPM. The over- whelming majority of applications use two pumps, with one pump sized for peak flow conditions and the second pump designed for 100 percent standby. Control panel Sizing the System 17 Figure 2-3: Septic Tank Effluent Pump (STEP) system. Chapter 2 2/2/06 4:29 PM Page 17 design alternates pump operation so both get equal wear. Minimum submersible duplex station dimensions are determined by the physical size of the pumps, the discharge piping, and the controls. Total station volume a function of peak flow and pump capacity is the paramount factor. Critical considerations to be used in siz- ing the submersible lift station are as fol- lows, referring to Figure 2-7: Plan Area A: This area is established by calculation, but may be influenced by the dimensional requirements for the pumps, piping, and controls. Height H x : This dimension is normally Sizing the System 18 Figure 2-4: Grinder/solids-handling pump station. Chapter 2 2/2/06 4:29 PM Page 18 Sizing the System 19 F i g u r e
2 - 5 :
T w o - t a n k
S T E P
s t a t i o n ,
u s i n g
e x i s t i n g
t a n k
a n d
n e w
e f f l u e n t
t a n k . Chapter 2 2/2/06 4:29 PM Page 19 Sizing the System 20 F i g u r e
2 - 6 :
S i n g l e - t a n k
S T E P
s t a t i o n ,
i n
f i b e r g l a s s
o r
c o n c r e t e . Chapter 2 2/2/06 4:29 PM Page 20 specified by the pump manufacturer and is generally defined by the top of the volute. It is designated as the Stop or Shut-off level of the pump. The purpose is to preclude drawing air into the pump inlet and/or pre- vent vortexing. The volume resulting from this height is a residual volume, and can- not be included in the working or storage volume of the station. Height H min : This is the distance from the pump Start level to Stop level. When multiplied by Plan Area A, it defines the volume which will be removed from the station during each pump operating cycle. Note that the volume occupied by the pump and other equipment located in this area must be subtracted to obtain the usable or true volume of fluid removed. The net result defines the minimum rec- ommended pump cycle volume. Height H lag : The vertical distance between the turn On of the lead pump and turn On of the lag pump. This provides sys- tem protection should the lead pump fail or be incapable of keeping up with the inflow. Height H res : This is the height mea- sured from the Lag level to the level of the inlet pipe. This height can be used to deter- Sizing the System 21 Figure 2-7: Submersible lift station design considerations. Chapter 2 2/2/06 4:29 PM Page 21 Sizing the System 22 F i g u r e
2 - 8 :
T y p i c a l
d u p l e x
s u b m e r s i b l e
s t a t i o n . Chapter 2 2/2/06 4:29 PM Page 22 mine the reserve capacity available in the station a capacity available for emer- gency conditions, such as a power outage. Note that the reserve capacity is restricted to the station only and should not include inlet lines. The consulting engineer may choose a reserve volume that differs from the above. For example, the minimum pump cycle vol- ume can be increased as a safety factor. This volume should not be decreased by any significant amount, however, as there is a danger that the cycle time (pump On/pump Off) may be too short, which could shorten normal pump life. To keep the size of the lift station at a reasonable minimum, the pump capacity should be two times the inflow at critical or peak flow times. In other words: Q = 2 x Qin Where: Q = capacity of pump in GPM Qin = peak inflow to the station in GPM Normally the station would be a duplex configuration, with a second pump that would alternate with the first unit, to assist at extreme peak flows and provide a stand- by in case of failure of one pump. When sizing the pumps, the velocity in the piping system must also be considered. Generally, two to three feet per second (ft/sec) is considered sufficient to prevent sedimentation. This value can have a def- inite effect on sizing the pump. For instance, for 6-in. pipe, there should be a minimum flow of approximately 200 GPM. The preceding pump calculations are fairly simple and will, in general, result in proper sizing of small to medium lift sta- tions. However, many consultants use dif- ferent and more complicated methods involving leakage in pipe systems, rain or storm volumes, and future growth requir- ing increased station and pump capacity. Sizing the System 23 Figure 2-9: Two possible operating sequences in a multi-pump station. (Courtesy: ITT Flygt Corp.) Chapter 2 2/2/06 4:29 PM Page 23 Pump Cycle Volumes The following calculation will give pump cycle volumes for a typical lift station. It can be used for stations with one to three pumps and a total pumping capacity of up to 3,000 GPM. Use the formula: V min. = T min. x Q 4 Where: V min. = the minimum effective pump cycle volume in gallons. This is the volume between the Start and Stop levels in the station. The Stop level is normally at the top of the volute. The Start level should be somewhere below the inflow pipe to prevent possible sedimentation in the inflow pip- ing system. T min. = the minimum cycle time in min- utes, defined as the amount of time it takes to raise the liquid to the Start level and then to draw back down to the Stop level. This minimum cycle time is achieved when the pump capacity (Q) is two times the inflow (Qin). Q = pump capacity in GPM Example: Pump capacity (Q) is 500 GPM Minimum cycle time is six minutes (based on 10 starts per hour, as recom- mended by most submersible motor man- ufacturers) What is the minimum pump cycle vol- ume? V min. = T min. x Q = 6 x 500 4 4 = 3000 = 750 gals. 4 The minimum cubic area of any pump station will take into consideration the physical size of the pumps and piping, and the liquid they displace. The space between the pumps is generally a function of the piping, pump dimensions, and pump capacity. This is a necessary consideration to avoid restricting or obstructing inlet flow to each pump. Minimum spacing between pumps and minimum submergence, to pre- vent vortex conditions, must also be con- sidered. (A typical duplex installation is shown in Figure 2-8). Large Stations When designing large submersible pump stations over 3,000 GPM there are a number of additional considerations. When three or more high-volume pumps are oper- Sizing the System 24 Figure 2-10: Top down view of a four pump system. Figure 2-11: Side view of a sta- tion with one or more pumps. Chapter 2 2/2/06 4:29 PM Page 24 ating in a station, care must be taken in posi- tioning the pumps, to provide a clear flow to the volutes to avoid sedimentation, and in sequencing the operation of the pumps. There are two generally accepted meth- ods of performing the pump sequence. In Operating Sequence I (Figure 2-9), the pumps in a station start in sequence, one after the other, and stop in the reverse order. In this case, a more uniform output is obtained from the pumping station than is the case for Operating Sequence II. In Operating Sequence II, the pumps also start successively, but all of them then con- tinue to operate down to the minimum Off level. Operating Sequence II always requires smaller pump sump volumes than Sequence I. The starting order of the pumps should be alternated cyclically to distribute the run- ning time of each as equally as possible. A properly designed pump chamber ensures the even flow of water, without vortices or eddies, to the pumps. The inflow is distributed through the holes in the bottom of the inlet chamber opposite each pump. Figure 2-10 shows a top down view of a four pump station. Figure 2-11 shows a side view of the same station. In station design, the primary considerations are the distance from the inlet to the center line of the pump(s), the distance between the center lines of pumps in stations with more than one pump, the maximum distance from the center line of each pump to the nearest wall, and the distance from the edge of the tank or station wall to the pump baffle. When designing a particular installation, consult with the pump manufacturer who can help prepare a layout which will insure the even flow of water to the par- ticular type and style of pump used. Any air bubbles which enter with the water into the pump chamber rise upwards along the sloping underside of the inlet set- tling chamber and escape from the surface of the water near the vertical partition wall Since all of the water is in motion, there is little risk of sedimentation so long as the minimum dimensions are not exceeded by any significant amount. To obtain a larger sump volume, the best dimension to increase is the distance from the inlet chamber to the pumps. Since the water flows to the pumps over this path, sedimentation is prevented. The minimum water level in the pump chamber the minimum Off level for the pumps must be high enough so that the square holes in the bottom of the inlet chamber are always submerged. In addi- tion, it should be noted that the lowest water level is determined by the required Net Positive Suction Head (NPSH) for the pump and, in any event, should not be lower than the top of the pump casing. The size of any particular station is deter- mined by the number and physical size of the pumps, and by the output capacity per pump. When sizing a station, consult with the pump manufacturer. The pump manu- facturer can furnish specific recommenda- tions for minimum clearances between pump casings and between the side wall and the pump casings. The pump manu- facturer can also recommend pump loca- tion relative to the discharge connection base and the preferred distance between the pump sump and the pump inlet. Estimating Flows If actual system flows are available, they should be used as the criteria for sizing pumps and the volume of the sump. The preceding method is recommended. However, the state, city, or county may have a set of standards that consulting engineers must use. Each entity must be contacted before proceeding. Wherever such standards exist and they can differ depending on the area of the country or even in different parts of a state they generally override any other method of computing station design. Although some of these standards are not as accurate as working with flow charts, they simplify the design. When selecting the pump, some pub- lished standards simply say that in a two Sizing the System 25 Chapter 2 2/2/06 4:29 PM Page 25 pump station, each pump must be capable of handling flows in excess of the expect- ed maximum flow. A general standard for estimating flows is as follows: Number of homes to be serviced, times Average of 3.5 people per home, times Average or 100 gallons per person per day.* Therefore, if a station were being designed for 200 homes, the 24-hour inflow would be: 200 x 3.5 x 100 = 70,000 gallons per day (gpd). The average inflow to the station in GPM would then be: 70,000 gals. divided by 1,440 mins. or 48.6 GPM. Since both the station and the pump capacity must be sized as a function of the expected peak flow at any given time, the standard will call out a Peak Factor. The Average is then multiplied by the given Peak Factor. In the above example, with a Factor of 3.5, which is often used, the esti- mated peak flow would be 48.6 x 3.5 = 170 GPM. This appears to be simple but workable. Sizing the System 26 * With pressure collection systems or tightly-jointed gravity systems, the average per capi- ta flow is often as low as 50 gpcd. Chapter 2 2/2/06 4:29 PM Page 26 A submersible centrifugal pump is a rotary machine consisting of two basic parts the rotary element or impeller, and the stationary element or volute. General Theory A pump converts the energy provided by its motor to a combination of velocity and pressure energy through the impeller. The liquid being pumped surrounds the impeller. As the impeller turns, it imparts a rotating motion to the liquid. The head developed by this action is a function of the rotary speed of the impeller and the impeller vane diameter at exit. The expression of theoretical head (at zero flow) can be related to the law of falling bodies: H = V 2 2g Where: H = height or head, ft. V = velocity of moving body, ft/sec g = acceleration of gravity (32.2 ft/sec 2 ) When the height of fall is known (for example, H = 100 ft.), the terminal velocity can be determined - - in this case, V = 80.3 ft/sec. Conversely, if the direction of motion is reversed, a liquid exiting through an impeller vane tip at a velocity of 80.3 ft/sec reaches a velocity of zero ft/sec at 100 ft. above the impeller tip. (Figure 3-1) When the developed head required is known, the theoretical impeller diameter for any pump at any rotational speed and zero flow can be determined from the fol- lowing equation for peripheral velocity of a round rotating body: D = (229.2)V N Where: D = unknown impeller diameter, in. V = velocity (derived from 2gH), ft/sec N = rotational speed of the pump, RPM If the pump head is 100 ft. and the rota- tional speed is 1750 RPM, the formula indi- cates that a 10.52 in. theoretical diameter impeller is required. In the preceding formula, we saw that if the speed of a centrifugal pump is doubled, the head developed by the pump is quadru- pled. This is because the head developed is proportional to the square of the veloc- ity change. Doubling the operating speed of a cen- 27 Chapter 3 Selection of Submersible Pumps Submersible centrifugal pumps come in different designs, each with specific char- acteristics and capabilities to meet various operating conditions. Pump capacity is determined primarily by the speed, size, and design of its impeller, which creates liquid head and flow through its rotating motion. Other factors in capacity are fric- tion, leakage, and shock losses. The volute or stationary part of the pump guides the liquid being pumped through the discharge opening. The size of the impeller passages and the clearance between the impeller and the volute allows for the passage of solid particles in the liquid. This chapter discusses the many factors in the selection of submersible wastewater pumps for particular applications. Chapter 3 2/2/06 4:31 PM Page 27 trifugal pump also doubles the capacity which the pump can handle. This is because the velocity of the fluid through the impeller has doubled. For example, a pump capable of developing 50 ft. total head at 100 GPM when operating at 1750 RPM with a given impeller diameter will be capable of developing 200 ft. total head at a capacity of 200 GPM when operating at 3500 RPM. Let's go back to the formula relating head, capacity, efficiency, and brake horse- power: Head H = V 2 2g Capacity Q =VA BHP = QH K x efficiency Where: Q =capacity, ft 3 / sec K =constant = 3960 A =cross sectional area, ft 2 Assuming that the efficiency of the pump remains the same when we change the speed, we see that the horsepower increases by a factor of eight when the speed of the pump is doubled. This is because the capacity doubles when we double the speed, and the head quadruples and these two factors are multiplied together to arrive at the brake horsepower. For this reason, the speed of a centrifu- gal pump cannot be increased arbitrarily. A pump designed to operate at one speed will need a great deal of additional horsepower if it is to run at a higher speed. However, we can make use of the speed conversion when slowing a pump down, from 3500 to 1750 or from 1750 to 1150 RPM. Considerable energy is saved when pumps are slowed to provide the required flow. To get a rough idea of a pump's capa- bility, we assume the efficiency remains constant and apply the relationship given below, commonly called the Pump Affinity Laws. For a given pump and impeller diam- eter: RPM 1 = GPM 1 = head 1 1/2 = RPM 2 GPM 2 head 2 BHP 1 1/3 BHP 2 Or, to put it a different way: RPM1 = GPM1 or RPM2 GPM2 RPM 1 2 = head 1 or RPM 2 head 2 RPM 1 3 = BHP 1 RPM 2 BHP 2 Because a change in speed always results in a change in capacity, head, and horse- power, care must be taken in using these formulae. These formulae give a useful approximation of the final performance capability of the pump. A change in impeller diameter of a pump being operated at constant speed has essen- tially the same effect as a change in pump speed both result in a change in the speed of the liquid which leaves the impeller. The formulae which apply for Selection of Submersible Pumps 28 Figure 3-1: Law of theoretical head. Chapter 3 2/2/06 4:31 PM Page 28 changes in capacity, head, and horsepower as related to impeller diameter changes look exactly the same as they do for changes in speed. Even greater care must be taken in the use of these formulae than the formulae for change in speed. A change in the impeller diameter in a pump affects the basic relationship between impeller and volute, and this alters the design configu- ration of the pump. For this reason, the impeller change formulae should not be applied when the impeller diameter changes are more than about 10 percent. When larger diameter change is indicated, the best practice is to obtain new test curves from the manufacturer. Specific speed is a correlation of pump flow, head, and speed at optimum effi- ciency. It classifies pump impellers with respect to their geometric similarity. Specific speed is expressed as: N s = N (Q) 1/2 (H) 3/4 Where: N s = pump specific speed Q = flow at optimum efficiency, GPM Selection of Submersible Pumps 29 For a given pump and speed: Imp. dia. 1 = GPM 1 = head 1 1/2 = BHP 1 1/3 Imp. dia. 2 GPM 2 head 2 BHP 2 Or, to put it a different way: Imp. dia. 1 = GPM 1 = Dia. 1 2 = head 1 or Dia. 1 3 = BHP 1 Imp. dia. 2 GPM 2 Dia. 2 head 2 Dia. 2 BHP 2 Figure 3-2: Radial type impeller. Normally for low capacities with medium and high heads. Specific speed range 500 to 3000 RPM. Figure 3-3: Francis type impeller. This axial inlet/radial discharge style is normally used for lower heads. Specific speed range 1500 to 4500 RPM. Figure 3-4: Mixed flow impeller with combination axial and radial inlet and discharge for low head/high flow. Specific speed range 4500 to 8000 RPM. Figure 3-5: Propeller-type impeller. For low head, low speed, and large volume. Specific speed above 8000 RPM. Figure 3-2 Figure 3-3 Figure 3-4 Figure 3-5 Chapter 3 2/2/06 4:31 PM Page 29 The specific speed of an impeller is defined as the revolutions per minute at which a geometrically similar impeller would run if it were of a size that would discharge one GPM against a head of one foot. Specific speed is indicative of the shape and characteristics of the impeller. Centrifugal pumps are divided into three classes radial flow; mixed flow; and axial flow. There is a continuum design change from the radial flow impeller (which devel- ops head principally by the action of cen- trifugal force) to the axial flow impeller (which develops most of its head by the propelling or lifting action of the vanes on the liquid). Typically, centrifugal pumps can also be categorized by physical characteristics relating to the specific speed range of the design, as shown in Figures 3-2, 3-3, 3-4 and 3-5. Once the values for head and capacity become established for a given application, the specific speed range of the pump can be determined and specified to assure optimal operating efficiency. Solids-Handling Design When used in sewage handling installa- tions, a further criteria is required in impeller selection the ability to pass solid particles through the impeller pas- sages. There is a wide choice of solids han- dling impellers in either semi-open or enclosed configurations, and either single, two or three vane types. Vortex or recessed impeller designs are also available. An explanation of these types follows. Semi-Open Non-Clog: An impeller with a solid back plate, to which the vanes are attached, is called a semi-open impeller. (Photo 3-6) Clearances between the impeller and volute can be restored by reshimming. A disadvantage is the axial load resulting from pressure imbalance between the open and closed sides; how- ever, the bearings are designed to handle this load. (Figure 3-7) Enclosed Non-Clog. When a solid plate is put on both sides of the impeller, a closed or enclosed configuration exists. (Photo 3- 8) The advantage of this configuration is that a volute wearing ring is used, which results in higher pump efficiencies. The disadvantages are more complicated fabri- cation and the need for slightly larger axial space. (Figure 3-9). VortexMulti-Vane: Solids handling oper- ation can also be accomplished with a vor- tex or recessed impeller. With this configu- ration, a vane with a shortened height is used so that the vast majority of liquid pass- Selection of Submersible Pumps 30 Figure 3-7: Graphic portrayal of unbalanced axial forces in a semi-open impeller. Figure 3-9: Unbalanced axial forces in an enclosed impeller. Figure 3-11: Vortex or recessed impeller. Chapter 3 2/2/06 4:31 PM Page 30 es between the top of the vane and the volute by whirlpool action, thus ensuring a definite non-clog condition. (Photo 3-10). The primary advantages of this impeller style are the reduced radial loading and the ability to pass long, stringy particles. The disadvantage is reduced efficiency. (Figure 3-11) Volute It is the function of the pump volute, often referred to as the pump casing, to col- lect liquid discharge from the impeller and direct it through the discharge nozzle or opening of the pump. The volute is designed so that, at one point, its wall is very close to the outer diameter of the impeller. This point is called the cutwater or tongue of the volute. Between the cutwater and a point slight- ly beyond, a certain amount of liquid has been discharged from the impeller. This liquid must rotate with the impeller until it is finally discharged through the outlet nozzle of the pump. Additional liquid is dis- charged from the impeller at every point around the volute, and this must also trav- el with the impeller and be discharged through the outlet nozzle. As the liquid continues around the volute, more and more volume accumu- Selection of Submersible Pumps 31 Photo 3-6 (left): The semi-open impeller is easily fabricated. Its vanes are attached to a solid black plate. Photo 3-8 (center): The closed impeller pro- vides more efficient operation by eliminating spillover between passages. Photo 3-10 (right): The vortex or recessed impeller prevents clogging by passing most of the liquid between the top of the vane and the volute by whirlpool action. Figure 3-13: Typical performance of a centrifugal pump. Figure 3-12: Volute and impeller rela- tionship in a centrifugal pump. Chapter 3 2/2/06 4:31 PM Page 31 lates, which must be carried around between the wall of the volute and the outer edge of the impeller. To keep the velocity fairly constant, even though the volume of liquid increases, the area between the tip of the impeller and the volute wall is gradually increased from the cutwater to the beginning of the discharge nozzle. (Figure 3-12) In a sewage handling (or solids handling) pump design, clearance must be provided between the impeller outside diameter (O.D.) and the volute cutwater to permit passage of solid particles as they exit the impeller passage as the vane tip passes the cutwater. Pump Performance Submersible centrifugal pumps are designed to operate over a wide range of discharge head conditions. A typical per- formance curve is shown in Figure 3-13. As this illustration shows, output flow and input horsepower increase as the dis- charge head decreases. The selection of a centrifugal pump for a particular applica- tion is usually made at the best efficiency point (BEP), which normally falls in the midsection of the pump performance curve. Operation at either extreme of the curve should be avoided. If a pump is oper- ated below the manufacturer's specified minimum head (high flow end of curve), motor overloading can occur. Conversely, pump selection in the extreme high head region of the curve results in low fluid flows, low efficiency, increased noise, and increased vibration. When sizing a centrifugal sewage pump, one has to consider pumping solids as well as the water. Solids require a minimum flow/velocity to keep them moving with the water in the pipe. Experience and test data have established this flow/velocity at 2 ft/sec. Water, therefore, has to be pumped at a minimum flow of 80 GPM in a 4-in. line and 175 GPM in a 6-in. line to achieve this velocity. At or below this flow, one risks the settling out or accumulation of solids in the line to a point where they may clog the pipe or possibly lock up or stall the pump. To avoid problems, manufacturers seek to restrict the use of a pump at low flow oper- ation with enclosed impellers and, to a less- er extent, with vortex or recessed impellers. Line blockage, however, can occur regard- less of impeller configuration. To determine exactly where the pump will operate on the performance curve, the system head/capacity curve must be estab- lished and matched to the pump perfor- mance curve. Figure 3-14 illustrates this. In System 1, the pump output flow would be X GPM at A head. In System 2, the pump output flow would be Y GPM at B head. System head curves are discussed in more detail later. Differing pump hydraulic characteristics will result in one pump being better suit- Selection of Submersible Pumps 32 Figure 3-15: How vane exit angles affect pattern of flow. Figure 3-14: Matching system pump curves. Flow increasing H e a d i n c r e a s i n g I d e a l
H e a d Flow Chapter 3 2/2/06 4:31 PM Page 32 ed for a given application than another. The following paragraphs examine head-flow curves, pump performance curves, and variations in curve shape as a function of specific speed and of Pump Affinity Laws. The head-flow curve of an ideal pump with ideal (frictionless) fluid is a straight line whose slope from zero flow to maxi- mum flow varies with the impeller exit vane angle. For example, a given impeller and casing combination with an impeller vane exit angle of 25 degrees will have greater maximum flow than a similar impeller with a 15 degree vane exit angle. (Figure 3-15) The actual head-flow characteristic of a centrifugal pump, however, is not an ideal straight line. Its shape is altered by friction, leakage, and the shock losses which occur in impeller and casing passages. Friction losses in a centrifugal pump are generally proportional to the surface rough- ness and the wetted areas of the impeller and casing. Leakage losses result from the flow of liquid between the clearance of rotating and stationary parts, such as impeller to the case wear-ring. Shock loss- es occur as the liquid enters the impeller entrance vanes and as the liquid flows from the impeller into the casing. These internal losses characteristically reduce pump performance from the ideal to the actual total head-flow curve shown in Figure 3-16. The flow at which the sum of all these losses is the least determines the point of maximum efficiency. Mechanical losses in bearings, packings, and mechanical seals further reduce pump efficiency. Although mechanical losses may be calculated, the results are generally not accurate; actual pump performance can only be determined by testing. Design Considerations Proper selection, operation, and applica- tion of submersible centrifugal pumps require evaluation of a number of factors. These include net positive suction head (NPSH), cavitation, submergence, vortex- ing, and siphoning. Net Positive Suction Head Available (NPSHA) is the absolute pressure of the liq- uid at the inlet of the pump. NPSHA is a function of elevation, temperature, and the pressure of the liquid, and is expressed in units of absolute pressure (psia). The net positive suction head required (NPSHR) by a pump includes the velocity head at the suction flange, plus the head losses occurring in the inlet line between the flange and the impeller. Minimum NPSHR, where it is a critical operating con- cern, is specified by the manufacturer. Submersible sewage pumps operate sub- merged in the liquid being pumped and are installed in wet wells vented to the atmos- phere. The NPSHA is determined by the submergence measured from the inlet of the impeller to the surface of the liquid in the wet well, plus atmospheric pressure, minus the vapor pressure corresponding with the liquid temperature. In most cases, minimal submergence plus atmosphere pressure will result in an adequate NPSHA. However, operating a pump with the fol- lowing conditions present may result in an inadequate NPSHA minimum submer- gence, flow rates higher than the Best Efficiency Point capacity, higher elevations, and/or elevated liquid temperatures. If these conditions exist, an analysis of the NPSHA in relation to the NPSHR is required. Cavitation: Cavitation in a centrifugal pump can be a serious problem. Liquid Selection of Submersible Pumps 33 Figure 3-16: Factors in establishing Best Efficiency Point (BEP). Chapter 3 2/2/06 4:31 PM Page 33 pressure is reduced as the liquid flows from the inlet of the pump to the entrance to the impeller vanes. If this pressure drop reduces the absolute pressure on the liquid to a value equal to or less than its vapor pressure, the liquid will change to a gas and will form vapor bubbles. The vapor bubbles will collapse when the fluid enters the high pressure zones of the impeller pas- sages. This collapse is called cavitation, result- ing in a concentrated transfer of energy which creates strong local forces. These high energy forces can destroy metal sur- faces; very brittle materials are subject to the greatest damage. In addition to causing severe mechanical damage, cavitation also causes a loss of head, reduces pump effi- ciency, and can be noisy. To prevent cavitation, centrifugal pumps must be provided with liquid under an absolute pressure which exceeds the com- bined vapor pressure and friction loss of the liquid in the area between the inlet of the pump and the entrance to the impeller. Submergence: A submersible centrifugal pump is cooled by the liquid surrounding it the fluid it is pumping. To assure prop- er cooling, the manufacturer normally specifies recommended minimum submer- gence for continuous operation. In addition to the cooling function, the interaction of submergence with cavitation, vortexing, and siphoning can readily be seen. Vortexing: This phenomenon results from pre-rotation of the liquid. Depending on the depth of the pump setting, the vortex may become severe enough to reach to the surface, at which time air can be drawn into the pump, resulting in reduced per- formance and/or cavitation. If vortexing becomes a problem, it can be eliminated or minimized by increasing the minimum submergence level or by adding baffles at the pump inlet to break up the vortex. Siphoning: If the ultimate level of the dis- charge line is below the level of fluid in the well, a condition termed "siphoning" can exist once the pump is started. Webster defines the term siphon as "A pipe or tube bent to form two legs of unequal length, by which a liquid can be transferred to a lower level, over an intermediate elevation, by atmospheric pressure forcing the liquid up the shorter branch of the pipe immersed in it, while the exccess of weight of the liq- uid in the longer branch (when once filled) causes a flow." The key words in the definition are "when once filled." The concern regarding a siphoning condition with a submersible centrifugal pump is that, once the pump is started, the siphoning will "assist" fluid flow and effectively reduce the head against which the pump must operate. If siphoning was overlooked in the selection Selection of Submersible Pumps 34 Figure 3-17 Figure 3-18 Chapter 3 2/2/06 4:31 PM Page 34 or sizing of the pump, this assist can result in the pump overloading due to operation below its minimum recommended head. Mechanical Design A submersible pump is designed and constructed to operate submerged in the liquid being pumped. This eliminates the need for inlet or suction piping and also provides cooling for the motor. Obviously this makes the unit flood-proof. The key components of a submersible pump are as follows. Rotating Elements: Made up of the shaft, bearings, and impeller. The single shaft design of submersible pumps reduces the deflection and bearing wear associated with traditional flexibly-coupled designs. It also permits more rigid construction, there- by permitting operation at other than the critical speed of the shaft. The bearings are either ball or ball/sleeve combinations, are permanently lubricated, and are positioned in the sealed motor cav- ity separated from the fluid being pumped. Mechanical Shaft Seals: The function of the seal in a submersible pump differs from that of a non-submersible, since it must protect against entry of liquid into the motor housing. Submersible pumps are available with single, double, or tandem seals. (Figures 3- 17, 3-18 and 3-19) Double or tandem sealed pumps can be equipped with a seal failure sensor located in the oil reservoir between the seals. This arrangement offers early detection of lower seal failure and thus greater protection for the motor. Pumpage, pressure, and speed each have their individual effect on the material, load- ing, and configuration selection of the shaft seals. These considerations interact with and upon each other to the extent that tol- erances and finishes may need to be adjust- ed to meet a single specific application. The pumpage has the single greatest effect on material selection. The standard combination of carbon-ceramic seals has successfully met a range of wastewater applications. For more severe applications and for longer service life, a wider selec- tion of materials is now available. The pump manufacturer should be consulted for specific recommendations. Pressure within the seal cavity must be considered to ensure that proper loading takes place at the seal faces. Too high a face load will cause wear, and too light a load may permit face separation and leak- age. The pump and seal manufacturers must coordinate so that the proper sealing occurs over the entire normal pump oper- ating range. Speed is normally a minor consideration in seal selection for submersibles because the maximum speed is only 3600 RPM. Motor and Motor Cavity: The submersible pump unit incorporates a liquid-tight motor cavity with proven field-serviceable Selection of Submersible Pumps 35 Figure 3-17: Single seal. Left is the motor side and right is the water side. Figure 3-18: Double seal. Figure 3-19: Tandem seals. (Photos Courtesy of Pac-Seal). Chapter 3 2/2/06 4:31 PM Page 35 motors, which are available in single or three phase designs and in a variety of common voltages. They range from approx- imately 1/2 to more than 1,000 HP and are offered in oil-filled and air-filled versions. Another important advantage of the sub- mersible pump is the added heat dissipa- tion obtained from the surrounding medi- um. In a non-submersible pump, the primary means of motor heat dissipation is by convection to the ambient atmosphere. Depending on installation, this can vary from frigid temperatures with maximum heat removal, to very high temperatures encountered on a summer day, made even hotter by a confined pit or building. With a submersible pump, heat transfer is accomplished by direct conduction to the rel- atively constant temperature fluid being pumped. This more efficient heat transfer method results in a lower operating temper- ature for the motor and its internal compo- nents, and helps extend the life of the motor. Wiring Cable Entry: The cable entry is designed to provide sealing amround the outside diameter (O.D.) of the cable. This permits complete pump submergence and provides strain relief to support the normal weight of the cable. The pump should never be lifted by the cable, since this strain relief is adequate for cord weights but will not support the weight of the pump. Most cables used are rated SO, SJO, SOW, or STO, and are designed for extra- hard usage. These types of cable have been accepted under the National Electrical Code (NEC) for use on submersible sewage pumps. Special attention is also given to jacketing compounds to prevent deteriora- tion from the liquid being pumped or from ambient conditions. System Losses And Head Curves The total dynamic head (TDH) that the pump must overcome consists of two major elements static head and friction head. Static head is the total vertical distance that the fluid must be lifted, from the lowest water level to the highest point in the dis- charge plumbing. Friction head results from the flow of the liquid through the dis- charge pipe, elbows, fittings, valves, etc. Each of these components is commonly expressed in feet (of water). The total dynamic head of the system is determined as follows. Static head is the actual vertical distance measured from the minimum water level in the basin to the highest point in the discharge piping. Friction head is the additional head creat- ed in the discharge system due to resistance to flow within its components. All straight pipe, fittings, valves, etc., have a friction fac- tor which must be considered. These fric- tion factors are converted to, and expressed as, equivalent feet of straight pipe, which can then be totalled and translated to friction head based on the flow and pipe size. System Sizing System sizing is based on three elements: data required, factors to be determined, and establishing the pump operating point. Data Required: Design flow (GPM) which the pump is required to produce at the total dynamic head (TDH) of the system. Static elevation of the system. Size of pipe being used. Type of pipe being used. Length of each size/type of pipe in system. C-factor of pipe (interior smoothness of pipe). Number and types of valves. Number and types of fittings. Sudden enlargements/restrictions in the system. Factors To Be Determined: Target pump capacity. This figure can be derived from local plumbing codes, design or average flow tables, or fixture unit values. This is then equated to gallons per minute. All of these factors vary depending on the type of application and Selection of Submersible Pumps 36 Chapter 3 2/2/06 4:31 PM Page 36 particular data. Friction losses within piping. Friction losses within valves and fit- tings. What type of pump will be utilized. The pump must be capable of developing the target flow in gallons per minute at total dynamic head above the static eleva- tion of the system, plus any pressure to be encountered if pumping into a force main. Establishing The Pump Operating Point: A table should be set up to determine the fric- tion losses based on the parameters defined by the system. The flow should be chosen in increments which will provide a suf- ficient number of data points above and below the intersection of the sys- tem curve with the pump characteristic curve. These losses can be determined for the pump size(s) and length(s) of pipe being used from the fric- tion loss tables presented in the Cameron Hydraulic Book, Hydraulics Institute Selection of Submersible Pumps 37 Figure 3-22: Pump characteristic curve a function of the pump design. Figure 3-23: Piping system character- istic curve a function of static head plus pipe, valve, and fitting friction. Figure 3-24: Matching pump perfor- mance and system loss curves. Chapter 3 2/2/06 4:31 PM Page 37 Selection of Submersible Pumps Table 3-21 FRICTION LOSS IN SCHEDULE 40 PLASTIC PIPE 38 Chapter 3 2/2/06 4:31 PM Page 38 Pipe Manual, Plastic Piping Systems Handbook, or the Appendix of this publi- cation. These values are usually given in fric- tion loss or head loss per 100 ft. of pipe. The head loss per 100 ft. of pipe fig- ure would then be multiplied by the over- all length of that type of pipe in the sys- tem. Then the friction losses for the valves and fittings must be determined. These val- ues are derived from tables presented in the manuals cited above. These values must be converted to fric- tion loss in the equivalent length of straight pipe so it can be added to the overall pipe length in the system. (Refer to Tables 3- 20 and 3-21 for typical values.) Selection of Submersible Pumps 39 Figure 3-25: Illustration of change in system flow resulting from duplex operations. Figure 3-26: System head and parallel multi-pump curves. Chapter 3 2/2/06 4:31 PM Page 39 Once all of these values have been determined, the system curve can be plotted on the same graph as the pump characteristic curve. This is illustrated in Figures 3-22, 3- 23 and 3-24, and is typical of the procedure presented in most pump application books. This procedure can also be used to analyze two pumps in equal parallel (a common discharge pipe with equal elevation and equal pipe lengths for each pump). The pump curve is adjusted to indicate double the capacity for a given head, and is then plotted with the system curve. Again, the intersection is the operating point of the duplex pump arrangement. (Figure 3-25) This procedure can be extended for any number of pumps operating in equal parallel. Figure 3-26 shows how individual pump capacity decreases and head increases as the number of operating pumps rise. This example of a system head and parallel pump curve illustrates centrifugal pumps of the same size operating in parallel. The result is a wide- ly varying flow for few pumps operating simultaneously, or a narrowly varying flow for a larger number of pumps operating simultaneously. Submersible Pump Sizing Most consulting engineers have a standard approach to lift station design. They consid- er and evaluate existing community needs, future development potential, local codes and regulations, elevations, force mains, etc., to arrive at a design flow. Chapter 2 (Sizing the System) discussed two methods of sizing a station handling flows of up to 3,000 GPM. One method discussed average daily flow, peak flow, etc., and pro- posed the formula: Q in = 60% of 24-hr. flow in gals. = GPM 4-hr. period in mins. and Q in = .60 x h x f = GPM 4 x 60 This gives the GPM flow into the station, which could also be considered the minimum design pump GPM. The second method discussed the number of homes, average number of people per home, and water usage per day, and presented a series of steps that could be converted to the formula: (# of homes) (# of people/home) (average flow/person) = inflow/day Q in = (inflow/day) (peak factor) minutes/day Either method will come up with about the same GPM. Chapter 2 discussed sump volume, with calculations to determine the minimum volume: V min. = T min. x Q in 4 At this point, we have determined: A. The inflow into the station or the design pump capacity in GPM. B. The minimum effective sump volume in gallons. The basic function of a submersible centrifugal solids handling pump is to pump a liq- uid with suspended solids from location and elevation A to location and elevation B. This assumes that A is at a lower elevation than B, and that A and B are connected by pip- Selection of Submersible Pumps 40 Chapter 3 2/2/06 4:31 PM Page 40 ing. EXAMPLE PROBLEM A consulting engineering firm has a contract to design a sewage lift station to move water from point X to point Y. It elects to use submersible solids handling pumps. (Figure 3-27) A. Q in , the design pump capacity, has been calculated at 375 GPM. B. The developed length from point X to point Y is 950 ft. C. The vertical distance from X to Y is 41 ft. D. New cast iron will be used for the discharge pipe. E. The engineer will design for a future condition, selected as 15 years from now. F. The engineer will recommend a duplex station with each pump sized to handle the full design capacity. G. To lift the water 41 ft. while moving it 950 ft., the water will pass through one tee, four 90-degree elbows, one check valve and one gate valve. Therefore: A. Design pump capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .375 GPM B. Discharge pipe length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .950 ft. C. Static elevation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41 ft. D. Pipe material used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .New cast iron E. Design piping system for . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 yr.-old C.I. pipe F. Type of system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Duplex, two pumps G. Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .All cast iron (7 total) When the pump turns On, it will push the water from point A to point B. It is neces- sary to size the piping system so that the pump will develop the capacity Qin (in GPM), Selection of Submersible Pumps 41 Figure 3-27: Example problem situation. Chapter 3 2/2/06 4:31 PM Page 41 Selection of Submersible Pumps Table 3-28 FRICTION OF WATER IN PIPES AND FITTINGS Hazen-Williams FORMULA C=100 Loss of Head in Feed Due to Friction per 100 Feet of 15 Year Old Cast Iron Pipe. 42 Chapter 3 2/2/06 4:31 PM Page 42 calculated previously at 375 GPM. To calculate TDH: 1. Select a tentative pipe diameter in this case, we will use 6-in. We must check for minimum velocity, which must be higher than 2 ft/sec, and for excessive velocity, which must be less than 10 ft/sec. 2. Calculate frictional loss, including design for old pipe and also for new pipe. 3. Add static head and friction head. As noted earlier, the lower limit, 2 ft/sec, is considered the minimum flow to keep the solids moving so they don't settle out and clog the pipe. The upper limit, 10 ft/sec, usu- ally results in an excessive frictional loss. In addition, since most sewage includes sand, grit or other abrasive material, this and higher velocities will sandblast the valves and fittings. (See Table 3-28 Charts A, B and C, for 15-year-old pipe and fittings.) To keep material costs down, we would first consider 4-in. cast iron pipe. At 375 GPM, both velocity and friction loss are high. At 400 GPM, Chart A shows a velocity of 10.21 ft/sec and a frictional loss of 16 ft. per 100 ft. This is excessive. Note that Chart C indi- cates that no adjustment to values for roughness is required, since the design is based on 15-year-old cast iron pipe. With 6-in. pipe at 400 GPM, Chart A shows a velocity of 4.54 ft/sec and a frictional loss of 2.21 ft. per 100 ft. This is reasonable. With 8-in. pipe at 400 GPM, Chart A shows a velocity of 2.60 ft/sec and a frictional loss of only .54 ft. per 100 ft. This is also reasonable but we should try the less expensive 6-in. pipe first. Frictional Loss Pipe length = 950 ft. Fittings: Refer to Chart B length of straight pipe which will give the same friction loss as listed. The result is Table 3-29, below. Table 3-29 6" Pipe Item Friction Loss Quantity Total Tee 33 1 33 90-degree Elbow 16 4 64 Check Valve 40 1 40 Gate Valve 3.5 1 3.5 Total: 140.5 ft. Total equivalent length what the pump "sees:" Pipe length 950 Fittings 140.5 1090.5 ft. Friction Head: Refer to Chart C. From Hazen-Williams, C = 100. This is our design for condition what is going to be the loss based on friction after 15 years' use. The chart is based on 15-year-old cast iron pipe, and no further adjustments or corrections are needed. Proceed to Chart A. Since 375 GPM is not shown, select the next highest value shown. Selection of Submersible Pumps 43 Chapter 3 2/2/06 4:31 PM Page 43 In this example, this value is 400 GPM. The friction loss at 400 GPM in 6-in. pipe is 2.21 ft. per 100 ft. The velocity is 4.54 ft/sec, which is satisfactory. (2.21/100) (1090.5) = 24.10 (friction loss) Therefore, static head = 41 friction head = 24.1 TDH = 65.1 feet The approximate design future conditions are 400 GPM at 65.1 feet TDH. We can estimate the brake horsepower by using the formula and assuming a pump effi- ciency (EP). A reasonable efficiency to assume is 55 percent. BHP = (GPM) (TDH) (3960) (EP) BHP= (400)(65.1) =11.96 (3960) (0.55) Therefore, we are looking for a pump in the 10 to 15 HP range. To determine the actual head at 375 GPM, we have to plot a system curve, or system head curve. To do this, we first must tabulate: 1. Various GPM flows from zero to something higher than 375 GPM. 2. The velocity at each flow. 3. The frictional loss or head at each flow. 4. Add the frictional and static head which equals TDH. 5. Plot the curve. Selection of Submersible Pumps 44 Figure 3-31: System head curve. Chapter 3 2/2/06 4:31 PM Page 44 Table 3-30 Calculation of TDH at 50 GPM Intervals Velocity Friction/ 100' Friction per Static GPM Ft/Sec C = 100 1090.5 Feet Head TDH 0 0.00 0.00 0.00 + 41 = 41.00 100 1.14 0.14 1.53 + 41 = 42.53 150 1.71 0.32 3.49 + 41 = 44.49 200 2.28 0.62 6.76 + 41 = 47.76 250 2.80 0.92 10.03 + 41 = 51.03 300 3.40 1.29 14.06 + 41 = 55.06 350 3.98 1.75 19.08 + 41 = 60.08 400 4.54 2.21 24.10 + 41 = 65.10 450 5.12 2.65 28.89 + 41 = 69.89 500 5.60 3.30 35.98 + 41 = 76.98 550 6.16 3.93 42.86 + 41 = 83.86 In this example, we will vary GPM from shutoff (zero) to 550 GPM. We will use 6-in. cast iron pipe. See Chart A, which tabulates velocity and friction for 15-year-old cast iron pipe. This is what Hazen-Williams set up as a standard, calling it coefficient C = 100. Using this data, we prepare Table 3-30. We can now plot the curve, with TDH on the vertical axis and GPM on the horizontal axis. This is the system head curve, Figure 3-31. It shows the head required to make a liq- uid flow through a system of piping, valves, elbows, etc. If we change any variable in Selection of Submersible Pumps 45 Figure 3-32: Pump perfor- mance curve with system head curve. Chapter 3 2/2/06 4:31 PM Page 45 the system, the slope of the curve will also change. From the curve, 375 GPM will require 63 feet TDH. Most system engineers have access to pump manufacturers catalogs, so at this point the engineer selects or has determined the design solid size and the maximum allowable RPM. The next step is to plot the system head curve on a typical manufacturer's performance curve for a 10 to 15 HP pump. (Figure 3-32) This may be done simply to be certain that one or several manufacturers can quote the pump. Or the engineer may select a spe- cific model and request a quotation on it or equal. Shown on the figure is pump performance with impeller diameters of 8-1/2-in. and 9-in. Also shown are lines of constant efficiency and horsepower. The pump selection could be a 15 HP unit with a 9-in. impeller. The performance is 420 GPM at 66.5 feet TDH. This is point A. The engineer should now calculate a new system head curve based on what flow and pressure will occur at start-up with new cast iron pipe, C = 130. By the same method as before, but this time using the coefficient C = 130 multiplier of 0.615 on column 4 (friction per 1090.5 ft.), we can calculate the frictional loss on aver- age new cast iron pipe (Table 3-33). Table 3-33 Calculation of TDH at 50 GPM Intervals Friction per 1090.5 C = 130 New Friction GPM Feet C =100 Mult. Per 1090.5 Feet Static TDH 0 0.00 times 0.615 = 0.00 + 41 = 41.00 100 1.53 times 0.615 = 0.94 + 41 = 41.94 150 3.49 times 0.615 = 2.15 + 41 = 43.15 200 6.79 times 0.615 = 4.16 + 41 = 45.16 250 10.03 times 0.615 = 6.17 + 41 = 47.17 300 14.06 times 0.615 = 8.65 + 41 = 49.65 350 19.08 times 0.615 = 11.73 + 41 = 52.73 400 24.10 times 0.615 = 14.82 + 41 = 55.82 450 28.89 times 0.615 = 17.77 + 41 = 58.77 500 35.98 times 0.615 = 22.13 + 41 = 63.13 550 42.86 times 0.615 = 26.36 + 41 = 67.36 We can now establish a new system head curve Figure 3-34. This system head curve crosses the 9-in. impeller performance curve at point B, or 510 GPM at 63.5 feet TDH. Pump efficiency is now 66.5 percent and calculated BHP is 12.3. The selection would still be a 15 HP pump. However, if the engineer specifically requests that the pump deliver the originally spec- ified 375 GPM at 63 feet TDH, the manufacturer could trim the 9-in. pump impeller to achieve this condition. This is point C on Figure 3-35. With this new impeller trim of approximately 8-5/8 in., the new pump efficiency is 63 percent and the new BHP is 9.47. This is the future design condition. Selection of Submersible Pumps 46 Chapter 3 2/2/06 4:31 PM Page 46 Selection of Submersible Pumps 47 The pump size could now be reduced to 10 HP. If a 10 HP pump is selected, installed with new cast iron pipe (C = 130), and equipped with the 8-5/8 in. impeller, it will operate at start-up at point D (Figure 3-36) and deliver: 465 GPM at 58.5 feet TDH. New pump efficiency is 66 percent. New BHP is 10.4. Figure 3-34: System head curve with new cast iron pipe. Figure 3-35: Trimmed pump performance curve with C=100. Chapter 3 2/2/06 4:31 PM Page 47 Selection of Submersible Pumps 48 This exceeds the pump nameplate rating. The pump will also draw more amperage than shown on the nameplate. In this example, the horsepower overload is minimal although it could be significant in other situations. Both present and future conditions should be checked, and overloading situations avoided. Duplex Sizing Figure 3-37 illustrates duplex pump performance with one system head curve. We have selected the system head curve, C = 100, as plotted previously, and are using two 15 HP pumps with 9-in. impellers operating in parallel. Figure 3-36: Trimmed pump performance curve with C=130. Figure 3-37: Duplex pump performance curve. Chapter 3 2/2/06 4:31 PM Page 48 Duplex pump performance is plotted by doubling the single pump's capacity at the same head. This condition holds true only if both pumps are discharging through a common main. Point E shows duplex pump performance 490 GPM at 76 feet TDH. Point F on Figure 3-38 shows that each pump will deliver half the capacity 245 GPM but at 76 feet TDH. Please remember that, with both pumps operating, the capacity of each pump is reduced and therefore pump efficiency and brake horsepower are also reduced. In this example, pump efficiency is 51 percent and brake horsepower is 9.2. Selection of Submersible Pumps 49 Figure 3-38: Duplex pumps, each providing half of capacity. Figure 3-39: Pump performance curves with differ- ent sized pumps. Chapter 3 2/2/06 4:31 PM Page 49 It is sometimes desirable to install two or more different sized pumps in the same well. Figure 3-39 illustrates pump performance with a 10 HP pump with an 8-1/2-in. impeller and a 15 HP pump with a 9-in. impeller. If they are operated singularly with the system head curve as shown, the 10 HP pump will deliver 350 GPM at 60 feet TDH and the 15 HP pump will deliver 420 GPM at 67 feet TDH. If they are operated in parallel discharging through a common main the combina- tion pump performance curve is drawn by adding the smaller pump's capacity to the larger pump's capacity, but only at the same head. 1. Transfer the zero flow, shut-off head, of the smaller pump point A to the larger pump's performance curve at the same head. Note Figure 3-40. Selection of Submersible Pumps 50 Figure 3-40: Resultant pump curve off two pumps in parallel. 2. At the same head assume 75 feet TDH add the capacity (65 GPM) of the smaller pump to the capacity (250 GPM) of the larger pump. 3. Continue adding capacities, at equal heads, until there is a locus of points. 4. Connecting these points results in a duplex performance curve of two unequal sized pumps running in paral- lel. The consulting engineer should also con- sider pump flexibility, history, service, and performance. Pump Flexibility Is this the largest pump the manufacturer makes in this model? What could the user do if he has to pull this pump out in a few years? Can it be replaced with the same pump model but with a larger impeller and higher horsepower? Pump history Is this a new or a tried and tested unit? Can the user depend on getting parts 15 to 20 years from now? Pump service Does the manufacturer have many of these units in operation? Do they have a good record? Is local service Other Considerations Chapter 3 2/2/06 4:31 PM Page 50 available? How much factory help can the user expect? Pump performance Has the pump selected for this application been sized to operate at or near the best efficiency point? As time goes by, will the pump decrease or increase in efficiency? Is there a possi- bility of operation at minimum head con- ditions? If so, will the pump draw exces- sive current and overload the motor? Can the user obtain motor efficiency and/or input KW to calculate wire-to-water or overall efficiency and thus calculate oper- ating cost? Summary and Reminders System curves can be expanded to incor- porate one curve at minimum sump level and the second curve at maximum sump level. This could become very important if the distance between the minimum and maximum levels becomes great. Where two or more pumps will dis- charge into a common header pipeline, it is usually advantageous to ignore the head losses in the individual pump discharge (called station losses) from the head capac- ity curves. This is advisable because the pumping capacity of each unit will vary depending on which units are operating in parallel. (A further discussion can be found on pages 57-59 of the Design of Wastewater and Stormwater Pumping Stations, WEF Manual of Practice: 1981.) In systems where there is high velocity, velocity head must also be considered. It is an additional pressure created by the high velocity of the fluids moving in the piping system which is not indicated on the pres- sure gauge. This head must be figured into the total dynamic head of the sytem. Velocity head can be determined by: h V = 0.00259(Q) 2 d 4 Where: h v = velocity head Q = GPM d = inside diameter of cir- cular pipe (inches) This formula is found on pages 3-6 of the Cameron Hydraulic Book. Friction tables detailing velocity head applications can be found in Cameron on pages 3-12 and 3-47. A pump station is normally designed to accommodate existing conditions with a capacity adequate for a specific time peri- od in the future. If the anticipated growth is large, an increase in capacity may be required. Options here include changing either the pump impellers or replacing the pumps with larger capacity units. The station could utilize an oversized discharge pipe if care is taken to maintain the velocity at or above 2 ft/sec. Another option is to lay parallel lines during initial construction. This permits both force mains to be used when the future capacity is reached. Final Example Results After the above analysis, you have: determined the actual operating con- ditions of the pump system in GPM and TDH selected a pump which operates at the best possible efficiency point and utilizes the minimum horsepower required to oper- ate in a non-overloaded condition determined whether the scouring velocity is within acceptable limits based on the type of wastewater being handled normally 2 to 5 ft/sec. You have also determined whether (if any parameter is not within acceptable lim- its) you need a larger capacity pump, or a pump with higher pressure capabilities, or smaller or larger pipe, or a different type of pipe, or a different piping arrangement. This system curve analysis gives the design engineer and the manufacturer of the equipment confidence about how the pumps will operate within the system, and that the proper equipment has been select- ed for the application. Selection of Submersible Pumps 51 Chapter 3 2/2/06 4:31 PM Page 51 52 Chapter 3 2/2/06 4:31 PM Page 52 General Description A typical dry well submersible pump sta- tion is shown in Figure 4-1. The pumped liquid is contained within the wet well (1) which is isolated from the dry pump cham- ber (2) by a wall. To minimize turbulence and air entrainment in the pumped liquid, a baffle (4) can be positioned in front of the inlet pipe (3). The liquid flows into the formed concrete sump (5), is drawn through a suction bell fitting (6), and into the suc- tion piping (9). The suction piping is attached to the suction flange of the pump with an elbow. A hand hole cleanout (10) is sometimes provided in this elbow. A suc- tion isolation valve (8) allows the inlet of the pump to be completely closed off in the event the pump must be removed for main- tenance. The suction piping passes through the wall between the wet well and dry well via a water tight wall fitting (7). The pump dis- charges through the piping (14). When appropriate, a prop- erly restrained flex- ible coupling (13) can be used to assist in alignment, and to reduce stresses on the pump volute caused by the pip- ing. An air release valve, check valve (16) and discharge isolation valve (15) are installed in the discharge piping. The pump is sup- ported by a steel stand (11) or con- 53 Chapter 4 Dry Well Submersible Pumps Submersible pumps, originally developed for use in applications where the pump unit will be submerged in the pumped liquid, are now widely used in dry well sta- tions where the wet well is separated from the dry pump chamber. Dry well sub- mersibles offer both the installer and the user several distinct advantages over con- ventional dry installed pumps. Their compact design, installation versatility, and resistance to damage from flooding make them ideal for use in both new and retro- fit pumping stations. Figure 4-1: Typical Dry Well Submersible Pump Station. Chapter 4 2/2/06 4:32 PM Page 53 crete foundation. The pump power cables (16) extend up and out of the dry well and into the electrical control panel. Where required, a venting valve and line (12) is installed to vent air out of the pump volute and suction piping. A level control system (19) installed in the wet well determines the running cycle of the pump. The pump motor is cooled by the use of one of sev- eral different types of cooling systems, dis- cussed later in this chapter. Advantages To the installer, the primary advantages of dry well submersibles are compact design, versatility in mounting, and easy startup. Because of the design of the sub- mersible pump, the pump and motor form a compact, close coupled unit, which is typ- ically smaller in physical size than the equivalent horsepower conventional dry installed pump. Because of their compact size, dry well submersibles can be installed in a smaller dry well than conventional dry installed pumps, reducing station construc- tion costs. Many manufacturers offer dry well sub- mersible pumps that can be mounted either vertically or horizontally, making them a good fit for new stations or retrofit of older, conventional dry installed pump stations. Pumps mounted horizontally are best suit- ed for stations with low vertical clearance in the dry well. Horizontal mounting is also ideal for those stations that have low NPSH available. This is because horizontally mounted dry well submersibles do not require an inlet elbow, allowing the pump inlet to be positioned lower vertically, rela- tive to the wet well liquid level. The dry well submersible pump typical- ly arrives at the job site fully assembled and ready to run, minimizing setup and startup costs. Since, on a dry well submersible, the pump and motor share the same shaft, there is no need for precision leveling, and shaft /coupling alignment after installation. Once the piping is aligned and installed, and the pump secured per the manufac- turers recommendations, the mechanical installation is complete. No sophisticated leveling or shaft alignment equipment is typically required. For the user, the primary advantage of the dry well submersible station is that acci- dental flooding of the station will not dam- age the pumps. Because the pumps are fully submersible, water tight units, they will continue to run, and will suffer no damage as a result of accidental flooding of the dry well. Dry well submersible pumps also require very little routine maintenance (see chapter nine for recommended mainte- nance). Unlike conventional dry installed pumps which may require routine packing adjustment, greasing of bearings, and main- tenance of couplings, dry well submersibles using mechanical seals, oil filled seal hous- ings, and permanently lubricated bearings, require none of this routine maintenance. Many dry well submersible pumps are equipped with integrated monitoring devices to warn the station operator of mechanical seal failure, moisture in the motor, and over temperature of the bear- ings and motor winding. These devices warn the operator that pump maintenance is required prior to pump failure. Vibration monitoring devices can also be installed on a dry well submersible so that maintenance personnel can perform regular vibration assessments. In the event maintenance is required, the complete pump can be removed as one unit, and can be serviced and fully tested by the service shop prior to reinstallation. Applications Dry well submersibles are ideally suited for a wide variety of applications in both the municipal and industrial wastewater markets. Like their submersible wet well counterparts, dry well submersibles are classified as solids handling wastewater pumps, capable of pumping contaminated liquid which may contain large solids. Nearly any application where a conven- tional dry installed pump would be used, is a potential application for a dry well sub- mersible. Example applications include pumping of wastewater or process water in industrial facilities, pumping of wastewater Dry Well Submersible Pumps 54 Chapter 4 2/2/06 4:32 PM Page 54 in treatment plants, sewage lift stations, and flood control stations. Retrofit of conventional dry installed pumps is another area where dry well sub- mersibles excel. Because of their compact size and mounting versatility, they can eas- ily be installed in place of either vertical or horizontal dry installed pumps. Line shaft support members, and custom made steel base plates, which are often required with conventional dry installed pumps, are typi- cally not required for dry well submersibles. Relatively simple dry well stands can be manufactured to support and position the dry well submersible pump so that piping changes required for retrofit are minimized. Pump Station Design Dry well submersible pump stations are divided into two sections, the wet well and the dry well. The wet well is sized to pro- vide adequate storage volume for the expected inflow, and to minimize the num- ber of starts per hour that the pumps will experience. The wet well must also contain the necessary features to provide good suc- tion conditions to the inlet of the suction piping, screens to prevent oversized solids from entering, and provisions for liquid level monitoring. The dry well must be of adequate size to accommodate the pump(s) in their intended mounting configuration (vertical or horizontal), and all piping com- ponents. Adequate space in the dry well must also be provided for maintenance per- sonnel to service the pumps. Vertical access and a lifting means must be provided so that the pumps can be easily removed for repair should a failure occur. A sump and submersible sump pump should always be included in the dry well for drainage. Suction and Discharge Piping In submerged applications, the sub- mersible pump has a flooded suction, and does not require suction piping to transport the wastewater to the inlet of the pump. Suction losses are therefore minimal, and limited to those caused by design of the actual inlet of the pump. With submersible pumps in a dry well installation, the pump must draw the wastewater through a pip- ing system and into the suction of the pump. As a result, all piping design con- Dry Well Submersible Pumps 55 Figure 4-2: Properly designed suction piping system. Chapter 4 2/2/06 4:32 PM Page 55 siderations which apply to conventional dry installed pumps, also apply to dry well sub- mersible pumps. As with all piping systems, suction and discharge piping in a dry well submersible pump station must be properly supported and restrained. The pump volute must not be relied on to support suction and dis- charge piping systems. In addition, the pip- ing must be properly restrained to prevent movement and vibration during pump oper- ation. Failure to provide proper piping sup- port and restraint can result in the trans- mission of excessive forces to the pump volute, objectionable noise, excessive vibra- tion, and possible component failure. In those stations where water hammer is of concern, the piping system must include water hammer abatement measures to pre- vent damage from water hammer. Piping and fittings must also be of the proper size, material, and pressure rating for the par- ticular pumping application. On the suction side of the pump, careful consideration must be given to losses in the piping system to prevent detrimental effects on the pump and its performance. A prop- erly designed suction piping system as shown in Figure 4-2, has the following fea- tures and characteristics: Total length of the suction piping from inlet to pump is as short as is practical. Piping is as straight as possible (min- imal number of bends and fittings). Bell mouth fitting should be used in the wet well to reduce velocity and loss at the entrance to the piping sys- tem. Sharp edge inlet fittings should be avoided. Piping inlet must be positioned far enough below the liquid surface to prevent the pump from pulling a sur- face vortex. Vortex suppression mea- sures must be installed in those sta- tions where surface vortices are likely due to low wet well liquid level. Isolation valve(s) are full port type valves resulting in minimal flow dis- turbance. There should be no check valves in the suction piping. Piping and fittings must not be small- er than the nominal pump suction diameter. Flexible couplings to aid in piping alignment are to be used only if prop- erly restrained. When possible, reduction from suc- tion pipe size to pump inlet size should be done using a reducing elbow attached to the pump suction. Where a reducing elbow is not used, straight reducer fittings must be of the eccentric type, oriented with the straight side up, to prevent air pock- eting. Straight reducers are installed as near to the suction elbow as possible. Suction piping slopes down away from the pump to prevent air pocketing. Piping is sized to provide high enough liquid velocity to prevent solids from settling. Many of the same rules apply to the dis- charge piping of the pump, although head Dry Well Submersible Pumps 56 Figure 4-3: Vertical mounted dry well submersible pump. Chapter 4 2/2/06 4:32 PM Page 56 losses on the discharge side are not nor- mally as big a concern as on the suction side. Discharge piping features include: Piping is as straight as possible (min- imal number of bends and fittings) to reduce head loss. Isolation valve(s) are full port type valves resulting in minimal flow dis- turbance. Check valve sized and selected according to the requirements of the particular application. Piping and fittings must not be small- er than the nominal pump discharge diameter. Flexible couplings to aid in piping alignment are to be used only if prop- erly restrained. Water hammer abatement measures must be included in those installa- tions where water hammer is a con- cern. An air release valve may be required in the discharge piping to vent accu- mulated air. Piping is sized to provide high enough liquid velocity to prevent solids from settling. Detailed piping design guidelines are available from the pump manufacturers and from the Hydraulic Institute. Please refer to these sources for detailed recommendations on pump station and piping design. Pump Mounting Arrangements The two basic mounting positions for dry well submersible pumps are vertical and horizontal. Vertical mounting as shown in Figure 4-3 is the most commonly used. A suction elbow attached to the suction pip- ing directs the flow up into the suction of the pump. The suction elbow can be equipped with a hand hole cleanout to facil- itate removal of debris from the suction elbow. The volute is supported by a fabri- cated steel stand, a combination of a steel base plate and poured concrete foundation, or an integrated cast suction elbow with a stand. The stand or base plate is attached to the concrete floor or foundation with anchor bolts. The design of the pump sup- port depends on the configuration of the volutes mounting pads, and the physical size and weight of the pump assembly. The motor shaft in this type of arrangement is vertical, and the discharge of the pump is horizontal. Advantages of vertical mounting include: Minimal floor space required result- ing in a smaller dry well chamber. Easier accessibility for maintenance. Motor with impeller attached can be lifted out vertically for easy cleanout in the event the pump becomes blocked with solids. All dry pit submersibles can be mounted this way. An alternative to vertical mounting is horizontal mounting, which some pump manufacturers offer as an option. In this arrangement, shown in Figure 4-4, the pump lays horizontally on specially designed support brackets. These supports are fastened to the concrete floor or foun- dation with anchor bolts. The straight run of suction piping is attached to the suction flange of the pump. The motor shaft in this type of arrangement is horizontal, and the pump discharge is vertical. Advantages of horizontal mounting include: Pump suction is lower to the ground allowing lower wet well liquid levels Dry Well Submersible Pumps 57 Figure 4-4: Horizontal mounting of a dry well submersible pump. Chapter 4 2/2/06 4:32 PM Page 57 and helping with NPSHA problems. Lower headroom required in the dry well, allowing construction of a lower profile pump station. Pump is less likely to become air bound. Suction piping is typically simpler, and may have less head loss. Mounting system is typically more rigid. With both vertical and horizontal mount- ing, the pump mounting base or stand must be properly leveled, grouted, and anchored. A properly leveled and anchored base ensures that the pump will operate with minimal vibration. Cooling Systems Electric motors generate heat when run- ning. This heat must be dissipated through some means to prevent damage to the motor. When submersible pumps are used in a wet well configuration, the pumped medium surrounding the motor provides cooling through direct contact of the pumped liquid with the motor. When sub- mersible pumps are used in a dry well con- figuration, some form of cooling system may be required to help cool the sub- mersible motor. The various manufacturers of submersible pumps use several different types of cooling systems. There are five basic types as outlined below. Each type of system has its own merits and appropriate applications. In all cases, the cooling sys- tem for a dry well submersible pump must have adequate capacity to carry off the heat generated by the motor, and must be sealed from the outside environment to prevent escape of any cooling fluid into the dry well environment. Pumped Media Cooling System An open loop cooling system (Figure 4-5) is designed to utilize the liquid being pumped as a cooling medium. In this Dry Well Submersible Pumps 58 Figure 4-5: Open loop cooling sys- tem. Figure 4-6: Closed loop cooling system. Chapter 4 2/2/06 4:32 PM Page 58 design, the motor is surrounded by a cool- ing jacket, which is sealed from the outside environment. A small portion of the pumped liquid is diverted into the cooling jacket, and circulated around the motor to provide cooling. The liquid is then returned to the volute to be pumped out. Normally, circulation is accomplished by specially designed pumping vanes on the back side of the pump impeller. Closed Loop Cooling System A closed loop cooling system (Figure 4-6) circulates cooling fluid around the motor and through a heat exchanger. The cooling fluid is kept separate from the pumped fluid, so that they are never allowed to mix. The fluid is normally circulated through a cooling jacket surrounding the motor which is sealed from the outside environment. It is then forced through a heat exchanger which may be either integrated into the motor, or may be an external device. Circulation is accomplished either by an external circulation pump, or by a circulat- ing impeller within the closed system, which is driven by the main pump shaft. The closed loop cooling system is a self-contained system that does not require make up fluid from an exter- nal source during normal operation. Typically a glycol mix is used as the cooling fluid, but some systems also use oil as the cooling fluid. External Coolant Feed An external coolant feed system (Figure 4-7) circulates cooling fluid supplied by some external source through a cooling jacket surrounding the motor. The external source is nor- mally a fresh water or plant water supply of sufficient pressure and flow volume to provide adequate cooling to the motor. A series of valves and reg- ulators in the coolant lines start and stop the coolant flow when required, and provide pressure and flow con- trol. Cooling water is normally drained into the wet well after circulating through the cooling system. Confirmation of the flow of cooling fluid through the cooling jacket is accomplished with an electrical flow switch connected to the pump control panel. Dry Well Submersible Pumps 59 Figure 4-7: External coolant fed system. Figure 4-8: Natural convection cooling. Chapter 4 2/2/06 4:32 PM Page 59 Natural Convection Cooling In some applications, natural convection (Figure 4-8) can successfully remove the excess heat. In these instances cooling fins on the motor are adequate to remove the heat without the assistance of fans and blowers. Often, motors using natural con- vection cooling systems have de-rated out- put power, and limited duty cycles. A vari- ation of the convection cooling design uses a fan mounted at one end of the motor to draw air across the motor to provide addi- tional cooling. This design can only be used in a dry well arrangement. Electrical Design Electric controls designed for use with dry well submersible pumps are very sim- ilar to those designed for conventional dry installed pumps, and for wet well sub- mersibles. A detailed treatment of electrical controls and level control systems can be found in chapter 6 of this handbook. There are however a few electrical installation considerations that will allow the user to get the full benefit of the flood proof design of a dry well submersible pump. Because the dry well submersible pump is completely water tight, it will not have a NEMA rated junction box on the motor suitable for accepting rigid or flexible liq- uid tight conduit. Rather, the motor will be provided with one or more flexible cables containing the power leads for the motor, the ground leads, and leads for any tem- perature or moisture sensors built into the submersible pump. Proper wiring of the motor requires that these power cord(s) be routed up and away from the motor, prop- erly supported, and terminated either directly in the control panel, or in an inter- mediate junction box located outside the potential flood area of the dry well. Under no circumstances are the cables to be ter- minated in a junction box or disconnect switch located in an area of the dry well that could accidentally flood. To do this would eliminate one of the most significant advantages of the dry well submersible pump; namely, its ability to continue to run undamaged in the event of an accidental flood of the dry well. If it is absolutely nec- essary to terminate the cables at a point that could be flooded, a watertight enclosure and fittings suitable for submergence (such as those with a NEMA 6 or 6P rating) must be used to prevent the cable ends from being exposed to the liquid. Dry well submersible pump power cables should be laid in open cable trays rather than pulled through conduit to facilitate their removal in the event the pump must be removed from the station for mainte- nance. Summary Ideal for either new stations or retrofit of existing stations, the dry well submersible pump offers unmatched versatility and flex- ibility for wastewater pumping stations. The compact, self contained design offers installers significant savings in installation cost over conventional, coupled dry well pumps. The fully submersible, integrated motor design of the pump offers operators trouble free pumping, even in the event the dry well becomes flooded. With a wide range of pump sizes, motor powers, and impeller types available, dry well sub- mersible pumps offer alternatives to con- ventional, coupled pumps in nearly every type of wastewater pumping application. Dry Well Submersible Pumps 60 Chapter 4 2/2/06 4:32 PM Page 60 Applications Applications range from one pump serv- ing a single building and discharging to any available gravity sewer to completely pres- surized systems transporting to dedicated treatment works serving thousands of con- nections. Pressure sewer systems using grinder pumps are particularly useful in new construction of subdivisions and sec- ond home communities, and in existing communities with failing septic tanks. The problems of failing septic tanks, unsatisfactory soil conditions, and an increased emphasis on environmental issues can be economically solved with pressure sewers, whether it be in estab- lished suburban neighborhoods, or shore- line property with leachate degrading the water quality. Because pressure sewers are compatible with other collection system techniques, the advantages of each tech- nology can be blended into site-specific designs using grinder pumps, gravity, large submersible pumping stations, and force mains. There is virtually no limit to the type discharge point to which a pressure sewer using grinder pumps can be connected. Choices in common use include: all types of treatment works, force mains, larger sub- mersible pump stations, and gravity sewers. Advantages It is a straightforward calculation to esti- mate capital cost of a gravity system com- pared to other alternatives at the start of a project since no economic projections or estimated future costs are involved. In some collection and treatment systems, the collection portion comprises up to 90 per- cent of the total construction cost. Capital cost savings of 50 percent compared to gravity flow systems are commonplace. Savings as high as 80 percent have been realized on some projects. Extremely low operating and mainte- nance (O&M) costs have been document- ed. Data are now available from many suc- cessful systems some in operation since the early 1970s. By taking advantage of the experience which these systems offer; a new system can be planned which will have good performance, high reliability, and reasonable O&M costs. Pressure sewers can be used where grav- ity systems just wont work because of uphill topography, surface rock, high water table, waterfront locations, very flat land, extreme cold weather, stream crossings, restricted access, and constraints on blasting. Because the piping systems are sealed, 61 Chapter 5 Grinder Pumps and Pressure Sewers Grinder pumps disintegrate or grind the solids in wastewater to fine particles (1/4 to 1/2-in. or less) so they will pass freely through the passageways of the pump, pipeline, and accessories such as valves. The pump discharge size can therefore be considerably reduced (typically 1-1/4 in. diameter). Since smaller piping can be used, cleaning velocities will be obtained at lower flows. This, in turn, allows the electric power available from a residential service entrance to be most efficiently used in providing higher heads at moderate to low flows, as required by the basic hydraulics of pressure sewer systems. Chapter 5 2/2/06 4:34 PM Page 61 pressure sewers offer freedom from infil- tration/inflow. This provides a twofold ben- efit. The wastewater treatment plant can be built with smaller tankage since it is not necessary to allow for storm peaks, and the treatment process will not be upset by storm related flows which can literally swamp out plants with infiltration/inflow plagued gravity collection systems. Since the piping system consists of small, light PVC or HD polyethylene pipe, laid just below the frost line in shallow, narrow trenches, the construction of pressure sew- ers causes very little environmental trau- ma. Strict vertical or horizontal pipe align- ment is not required, so lines can be placed around natural or constructed obstacles. Disruption to daily living is generally minor when compared to the installation of other types of sewer lines. Design Criteria Systems are laid out in branched net- works. This assures that minimum neces- sary cleansing velocities (usually 2.0 ft/sec) will be achieved, since flow can be only in a single planned direction. In general it is best to install one pump station for every house. It may seem to be an economic advantage to share one pump between two or three houses, especially if they are small or seasonal residences. This has been tried in a few places, but problems usually arise because of questions like these: Who pays for electricity? Who pays for service calls? Upon whose land shall the pump be located? Pressure rated plastic pipe is used in all pressure sewer sys- tems. Type SDR-21 PVC is the most frequent choice in the United States. High density polyethylene (HDPE) is popular in Europe and Canada, primar- ily because it will withstand repeated freeze/thaw cycles without burst- ing. Since HDPE is available in long con- tinuous rolls, fewer joints are required. There are fewer diameters available in the smaller sizes which leaves some design gaps when optimizing the trade-offs between velocity and friction loss. For PVC or HPDE pipe, a friction fac- tor of C = 150 used in the the Hazen- Williams formula has been shown by Plastic Pipe Institute research to be a real- istic choice because the surface is so smooth when new, and ages very little. This decreases the calculated friction losses, and means that any given pump will operate satisfactorily over a much longer distance, than if other pipe materials, with corre- spondingly lower C factors, were used. Design flow, in any given downstream section of line, as a function of number of pumps contributing, has been determined empirically; and is available in tabular or graphic form. Figure 5-1 shows these cri- teria as suggested by several competent authorities. 2 Once these choices have been made and a plan view map is drawn, it is a matter Grinder Pumps and Pressure Sewers 62 Figure 5-1: Design Flow Criteria. Chapter 5 2/2/06 4:34 PM Page 62 of choosing pipe diameter for each section in the system. Methods vary from one manufacturer to another, but all design pro- cedures are intended to select the largest size pipe that will achieve an effective cleansing velocity (usually 2.0 ft/sec mini- mum) at least daily. This minimizes fric- tion losses and assures that the available pumping head achieves the maximum use- ful work. Various accessories including end of line cleanouts, access points, and air and vacu- um relief valves may be added as site details dictate. Application assistance in special situations such as seasonal occu- pancy, long residence times, and slow build out is available from members of the Submersible Wastewater Pump Association (SWPA) based on their experience in a wide variety of applications. All offer appli- cation assistance in the form of manual or computer-aided application procedures. For residential size grinder pump stations under normal circumstances, electric power should be fed from the house ser- Grinder Pumps and Pressure Sewers 63 Figure 5-2: Typical Grinder Pump Control Panel Circuit. Figure 5-3: Grinder pump char- acteristic curves. Chapter 5 2/2/06 4:34 PM Page 63 vice. A connection from the load side of the residential service panel to the grinder pump disconnect or control panel is pre- ferred. Electric energy usage for pumping is typically less than 20kWh per month. The minimum monthly charge for a sepa- rate power drop and meter would typical- ly be much greater than the cost of ener- gy actually used. Grinder pump control panels, which vary in complexity and func- tions, can be mounted on the outside of the house or on a free standing pedestal in an unobtrusive, but convenient location. A typical 230 volt control circuit diagram is shown in Figure 5-2. Equipment Residential grinder pumps are available in both centrifugal and progressing cavity designs. They are produced in 1 and 2 HP sizes with up to 2-in. discharge and may operate on either 1725 or 3450 RPM, depending on the design. Figure 5-3 shows typical performance characteristics of both centrifugal and progressing cavity type Grinder Pumps and Pressure Sewers 64 Figure 5-3: Typical grinder pump systems: progressing cavity (above) and centrifugal (right, facing page). Chapter 5 2/2/06 4:34 PM Page 64 Grinder Pumps and Pressure Sewers 65 Figure 5-4: Typical grinder pump systems: progressing cavity (left, fac- ing page) and centrifugal (above). grinder pumps. Since torque is directly pro- portional to horsepower and inversely pro- portional to speed, the two have compara- ble torque available for grinding. A grinder pump must be able to start up in the mid- dle of a grinding cycle with the cutting ele- ments full. Apartment buildings, schools, commer- cial, and light industrial applications are served by properly sized submersible grinder pumps rated at 3 HP and up, with 2-in. to 4-in. discharge. These are usually furnished in duplex configurations, with controls to alternate the pumps, and to allow for both On at once during abnormal peak flow conditions. Construction Grinder pumps and accessories may arrive at the job site as completely assem- bled stations or as individual parts to be Chapter 5 2/2/06 4:34 PM Page 65 Grinder Pumps and Pressure Sewers 66 Figure 5-5 Grinder Pump Project Start-Up Check List Chapter 5 2/2/06 4:34 PM Page 66 Grinder Pumps and Pressure Sewers 67 field assembled and erected. Figure 5-4 shows outline drawings of a typical pro- gressing cavity and centrifugal grinder pump. In either case, it is important that the installing contractor follow the manu- facturers installation instructions to the let- ter. For example, units should be lifted and carried only with designated eyes or an approved sling. If ballast has been specified by the engineer to prevent flotation, lifting eyes anchored in the ballast must be used. Pump stations should be transported and moved in the specified orientation only. If units are to be stored for more than a few weeks, manufacturers recommenda- tions must be followed. Indoor storage at controlled temperature is best, especially for long periods. Equipment which is pro- tected from condensed moisture by electric heaters should not be installed until power is available. All installation and start-up work should be done in orderly steps against a formal check list such as that shown in Figure 4-5. Operation and Maintenance Some components of grinder pump sys- tems may require periodic maintenance, such as regular grease removal and ser- vice of the cutter assemblies and impellers, to maintain optimal efficiency. Chapter 10 deals with operation and maintenance issues which are generally applicable to submersible pumps of all sizes. References 1) Neale, Lawrence C. and Price, Robert E.; Flow Characteristics of PVC Sewer Pipe; Journal of the Sanitary Engineering Division, ASCE; June 1964. 2) Bowne, William C., Naret, Richard C., Grinder Pumps in Pressure Sewers As this edition of the Submersible Sewage Pumping Systems (SWPA) Handbook went to press, SWPA was developing a new publication entitled Grinder Pumps in Pressure Sewers. When published in mid-2006, Grinder Pumps in Pressure Sewers will describe the many aspects of pressure sewer systems and how they work. This new pub- lication is expected to be about 48 pages in length, feature numerous full-color photographs, charts, graphs, and other visuals, and include sections on: General Description of Grinder Pumps in Pressure Sewers Advantages To Using Pressure Sewer Systems System Design Criteria Equipment Requirements Up Front Planning Installation and Start-Up Operations and Maintenance In its Appendix, Grinder Pumps in Pressure Sewers will also include an extensive glossary along with SWPAs Common Terminology and related draw- ings for these products. Visit the SWPA webs site at www.swpa.org for additional information on this new publication as well as the Associations other technical resources and spe- cial prepublication offers. Chapter 5 2/2/06 4:34 PM Page 67 Grinder Pumps and Pressure Sewers 68 Otis, Richard J., Manual Alternative Wastewater Collection Systems EPA/625/1-91/024; US EPA CERI; October 1991. Additional Information The Submersible Wastewater Pump Association (SWPA) has published a white paper entitled A Pressure Sewer Overview A Proven Approach to Moving Wastewater from One Point to Another, a series of Frequently Asked Questions (FAQs) and Answers about grinder pumps and pres- sure sewers and a series of Grinder Pump Definitions, Drawings, and Common Terminology. These and other materials related to grinder pumps and pressure sew- ers are included in a Press Information Kit available from the Association. To obtain a copy, contact SWPA Headquarters or visit the SWPA web site at www.swpa.org. Chapter 5 2/2/06 4:34 PM Page 68 Power Supply Primary Power Sources Where does electricity come from? Although a variety of resources are used to get electricity, the basic method of achieving and transporting electricity is the same. Electricity is generated by several methods. In order to generate electricity, utilities will use one of the methods listed in Table 6-1. The high voltage will be sent from the power plant to the end user by means of wires. Since the electricity is at a very high voltage and low amperage, the size of the wire to send the electricity will be small in 69 Chapter 6 Controls for Submersible Pumps The control system provides for the automatic operation of the submersible waste- water pumping station. Since most stations are in unattended locations, remote from central sewage plants, each station must function reliably. Control systems should be designed to perform as simply as possible, while ensuring that the spe- cific pumping job is done properly. They should incorporate such basic features as a short circuit protection disconnect for each pump, overload protection, Hand/Off/Automatic switches and pump run indicators. Acceptance by the engi- neering organization or local regulating authority may require acceptance by a rec- ognized third party. Care should be used in specifying the system and the accep- tance criteria. The control panel should be easy to maintain and troubleshoot by qualified service personnel. The control panel should include the panel serial num- ber, the horsepower, voltage, phase, frequency and full load amperage rating of the pump(s), as well as a wiring diagram and schematic. The phone number of the service organization should be placed on the control panel or a similar loca- tion and a wiring schematic should remain inside the enclosure. This chapter dis- cusses power supply, motor controllers, types of level controls, alarms, auxiliary system components, and control panel enclosures. ENERGY SOURCE MEANS OF CHANGING ENERGY OUTCOME Fossil Fuels Steam Powered Generators Electricity Geothermal Energy Steam Powered Generators Electricity Nuclear Energy Steam Powered Generators Electricity Solar Energy Sunlight Photoelectric Cell Electricity Wind Wind Turbine Generators Electricity Gravitational changes Hydro Turbine Generators (DAMS) Electricity Lunar Energy (TIDES) Hydro Turbine Generators (TIDES) Electricity Table 6-1: Methods to generate electricity. Chapter 6 2/2/06 4:36 PM Page 69 comparison to the size that would be need- ed to send the power at the end user volt- age. The high voltage electricity from the power plant travels through the utility line and is changed into a useable voltage by using a transformer. Electricity travels from the sub-station to the source where it will be utilized and transferred into the mechan- ical energy for doing work. In the case of a pump, the electricity is converted to mechanical energy via the motor. The motor spins the impeller, developing a pumping action to move the liquid. Identify the power available at the site selected for a pump station. The local Power Company usually establishes the type of power source. Depending upon the anticipated revenue from the installation, the power utility may consider accommo- dations not presently available. Electricity supplied to pump stations is in the form of alternating current. In alter- nating current (AC) systems, the electrons flow in both the positive and negative direc- tions. Figure 6-2 shows a graphical repre- sentation of alternating current that we call a sine wave. The vertical axis represents the direction and amplitude of the current. The horizontal axis represents time. When the waveform is above the time axis, current is flowing in what we have specified as the positive direction. When the waveform is below the time axis, the current is flowing in the opposite or negative direction. During first half of time period (time 1), current starts at zero magnitude, increases to maximum in the positive direction, and then diminishes back to zero. During second half of time period (Time 2), current flow reverses direction and immediately begins to increase in the neg- ative direction. Once it reaches maximum current flow, it diminishes until it reaches zero again. The pattern of alternating cur- rent flowing first in the positive direction Time 1 and then in the opposite (negative) direction Time 2 is referred to as one com- plete AC cycle. Alternating current goes through many such cycles each second. The rate of these cycles is called frequency. We represent the number of cycles per second (or frequency) in Hertz. For example, in the United States, alternating current is usually generated at 60 Hertz, or 60 cycles per second. In other parts of the world, such as Europe, alter- nating current is usually generated at 50 Hertz, or 50 cycles per second. There are two basic types of alternating current: single-phase and three-phase. Single phase AC is a continuous series of single AC cycles as shown in Figure 6-3A. Single-phase AC power is produced by a sin- gle-phase generator or one phase of a three phase generator. A single-phase AC power system has two electric lines that are capa- ble of conducting current, and typically includes a third wire configured as the neu- tral. Three-phase AC is a continuous series of Controls for Submersible Pumps 70 The products described in this Handbook, like all products using electrical current, can result in harm if not used with EXTREME CAUTION and in strict accordance with the manufacturers instructions and in accordance with local building codes and ordinances. Seek professional assistance if in doubt. Contact the manufacturer directly with questions and/or problems related to specific equipment, components, and accessories. Figure 6-2: Alternating current sine wave. Chapter 6 2/2/06 4:36 PM Page 70 three overlapping AC cycles as shown in Figure 6-3B. Note that each phase is off- set by one third of a cycle 120 degrees with a complete cycle at 360 degrees. In real time, each phase is offset by 1/180 of a sec- ond for a 60-Hertz supply. A three-phase generator produces three-phase voltage. A phase is any hot line that has voltage when measured with respect to an opposing phase or neutral. For three phase systems the hot or line voltage is also called L1, L2 or L3. A hot line can be any of the normal voltages such as 208, 230, 460, 600 V.A.C. A three phase electrical system has three electrical lines that are capable of conduct- ing current, and may include a fourth wire configured as the neutral. A voltage rating is the root mean squared (RMS) voltage for a system. The common North American voltages for single phase and three phase systems are referenced in Table 6-4. Note that voltages vary from location to location. The nominal voltage is highlighted. Refer to the pump manufac- turers motor nameplate to verify that the stated utilization voltage of the pump motor and line voltage correspond. What Voltages and Phase Are Available and Why? Three phase wye systems connect the phases to look like the letter Y. A WYE sys- tem is typically 4-wire system as shown in Figure 6-5. In a 4-wire system the neutral wire is grounded at the service entrance. The neutral voltage reference to any line (phase) will be equal. A neutral wire will have 0 volts with respect to ground. On wye configurations the voltage referenced from any phase to neutral will be line volt- age divided by 3. Three phase Delta systems connect the phases to look like the Greek letter delta. Controls for Submersible Pumps 71 Figure 6-3A: Single-phase sine wave. Figure 6-3B: Three-phase sine wave. 110 200 220 440 550 115 208 230 460 575 120 240 480 600 Table 6-4: Nominal voltages. Figure 6-5: 4-wire wye (Y) or star system. Chapter 6 2/2/06 4:36 PM Page 71 Delta systems are either three or four wire configurations. Delta systems may be ungrounded (with no neutral) or a ground- ed center tap configuration sometimes referred to as a wild leg configuration neutral referenced to L1 or L3 will have 120 VAC on a 240 VAC system. Neutral ref- erenced to L2 will be in excess of 280 VAC on 240 VAC systems. These two types of delta configurations are shown in Figures 6-6A and 6-6B. There are also open delta configurations in some regions. The voltage reference from phase to phase will not be balanced equal- ly in an open delta configuration, see Figure 6-6C. Open delta configurations must be checked to verify that the phase imbalance is within the motor manufactur- ers acceptable levels. A control system uti- lizing a variable frequency drive should not be used with an open delta 3three phase power source. 120 VAC systems can be derived from single or three phase systems. For the most part 120 VAC is derived from a three-phase system. This allows one system to supply single and three-phase power for an appli- cation. One such application may be the require- ment of 120 VAC single-phase control power and 208 VAC three phase power. In a three-phase system, 120 VAC can only be derived from 4 wire systems. If a WYE sys- tem is used the 3-phase voltage will always be 208 VAC (Figure 6-7A) while in a DELTA system the 3-phase voltage will always be 240 VAC (Figure 6-7B). The fol- lowing diagrams illustrate which electrical lines are used for three-phase power and single-phase power. Main disconnect is required for service entrance applications. It may be a fused or non-fused disconnect switch, a main circuit breaker in a separate enclosure, or built into the control panel. These devices are avail- able in a variety of NEMA-rated (National Electrical Manufacturers Association) and Controls for Submersible Pumps 72 Figure 6-6A: 3-wire delta system (ungrounded). Figure 6-4B: 240v delta system. Grounded center tap typically use on 230/240v systems. Figure 6-6C: Open delta system. Chapter 6 2/2/06 4:36 PM Page 72 UL listed (Underwriters Laboratories) enclosures to meet nearly any installation requirement (Figure 6-8). Standby Power Sources A standby or secondary power source may be required by the approving authori- ty. It generally is an engine-driven genera- tor set providing the same characteristics as the primary power source. If the generator set (diesel, gasoline, or propane) is perma- nently installed at the lift station, it usual- ly includes an automatic transfer switch which automatically starts the generator and transfers to standby power in the event of a primary power failure. If a portable generator set is used, two additional components are required. These are a standby power receptacle to provide a quick, safe way of connecting the stand- by source, plus a manual transfer switch to disconnect the normal power source and reconnect the load to the standby power. The manual transfer switch also functions as an isolator to prevent cross-connection of the two power sources. Care must be taken to assure that the inlet and mating connector are compatible. It is sometimes desirable to incorporate these components into the main pump con- trol panel. This can be done simply with two standard circuit breakers with walking beam interlocks (A locking slide between two breakers may not meet UL require- ments) or a dual horsepower-rated rotary switch with a (lockable) single three posi- tion operator mechanism. This may be more desirable to some users than a sepa- rate, bulky, expensive transfer switch. Whether a permanently installed or portable generator is used, the size of the standby power source required can be reduced by including a lock-out circuit in the control panel so only a selected num- ber of pumps can operate in the emergency mode. Controls for Submersible Pumps 73 Figure 6-7A: 208v wye (Y) system. Figure 6-7B: 240v Delta system. Grounded center tap typically use on 230/240v systems. Figure 6-8: Lift station control system with separate service dis- connect. Chapter 6 2/2/06 4:36 PM Page 73 Motor Controllers Across the Line Magnetic Contactors The most common form of motor con- troller is the across the line, full voltage, non-reversing (FVNR) magnetic starter. NEMA standards for these devices have been established to provide uniformity of size and horsepower ratings, and all are equipped with overload relays. They are available in several NEMA-rated enclosures for stand-alone use (see listing at end of this chapter), as well as open frame for installing in a control panel. Contactors (Figure 6-9) may be used in most applications in place of NEMA-rated starters; they will function equally well when sized to accommodate the motor in-rush current (Table 6-10). Since most con- tactors are either horsepower or ampere-rated, they should not be used for induction motors with full load amper- age above NEC tabulations. To comply with the code requirements for overload pro- tection, a separate overload relay is required when contactors are used to start three phase motors. Since many motor manufacturers include overload pro- tection as an integral part of single phase motors, separate overload control devices may not be required. Contactors in con- junction with overload relays provide an economical and satisfactory answer to motor control in many lift station applica- tions. Overload provisions for induction motors are required by the NEC. Typically over- load protection generally takes the form of an overload relay equipped with heater ele- ments. Current flows to the motor through these elements. If this current rises above the trip setting, the relay contacts are opened interrupting current to the starter Controls for Submersible Pumps 74 Figure 6-9: Motor contactors. Table 6-10: Motor contactor/NEMA starter minimum life at rated load. Definite Purpose: 100,000 Electrical cycles NEMA: Up to 10,000,000 Electrical cycles IEC: Up to 1,000,000 Electrical cycles Chapter 6 2/2/06 4:36 PM Page 74 or contactor coil, thus de-energizing this device and stopping current flow to the motor. For single-phase motors, when overloads are not integral to the motor, NEC requires only one heater element, unless a particu- lar manufacturer requires two heater ele- ments for warranty purposes. For three-phase motors, overload relays must have heater elements in all three power legs. Heater elements are generally of two types melting alloy or bimetal. The ambi- ent compensated, quick-trip type bimetal heater element is recommended for sub- mersible pump motor applications. In addi- tion to protecting against physical motor overload, this type of relay provides pro- tection against low voltage. Short circuit protection is required by the NEC. This usually takes the form of a fused disconnect, standard thermal magnetic cir- cuit breaker, or a motor circuit protector (MCP). Of the three types, a standard ther- mal magnetic circuit breaker is the most popular because it will trip with an over- load on any phase, it can be re-set, does not require a stock of proper fuses, normally meets code requirements for a disconnect means at the motor site, however, they typ- ically do not provide the same interrupt capacity as fuses. A standard circuit breaker in conjunc- tion with NEMA-rated starters or the con- tactor/overload relay combination general- ly provides the simplest means of integrating the motor controllers with the level control system, using a single control panel in an enclosure suitable for the envi- ronment. The MCP (Motor Circuit Protector) is a special form of circuit breaker with mag- netic only trip characteristics developed specifically for induction motors. It has no thermal overload capability. It is often used for higher horsepowers (25HP and up) and higher voltages where its cost is competi- tive. It must be used with a NEMA rated starter of appropriate size to maintain a UL listing. Ground Fault Interrupters Circuit breakers with ground fault inter- ruption (GFI) are available from some man- ufacturers and are intended primarily for personnel protection. They will trip when a current flow of approximately 5 mil- liamperes to ground occurs on the load side of the circuit breaker (Available only in cer- tain frame sizes and pole configurations). They are used primarily with single- phase convenience outlets, up to 30-ampere capacity. They offer protection to personnel when they are using portable drills, trouble lights, etc. Electrical codes usually require GFI protections for these applications. While GFI protection for pumps is avail- able, it is not required by the NEC for sewage wet wells. If used for this type of service, nuisance tripping of the pumps may occur because of the normally wet environment. Many solid state overload relays provide groundfault motor protection at a reasonable cost. When GFI protection is used, special consideration should be given to locating all electrical connections in a dry environment. Ground fault protection for pumps uses current sensors coupled with a solid state relay which has normally open or normal- ly closed contacts. The relay output may be used to trip the pump circuit breaker, pro- vided a shunt trip device is included, or it may be incorporated in pump pilot control circuit to de-energize the pump starter. It should be noted that this GFI Unit is to pro- vide equipment protection only. The current sensors are available with selectable trip ranges to provide any desired equipment protection level. This enables the selection of ranges sufficiently high to prevent nuisance tripping while providing adequate equipment protection. This type of GFI pump protection can substantially increase the cost of the system. Reduced Voltage Starters Reduced voltage starters are a means of limiting the motor in-rush (starting) current. They are required when it has been deter- mined usually by the utility that the Controls for Submersible Pumps 75 Chapter 6 2/2/06 4:36 PM Page 75 power supply at a given site is limited in the amount of induction motor in-rush cur- rent the primary system can handle. Five types are in general use for centrifugal pump motors: auto-transformer type, Wye- Delta starters, solid state (soft starters), Variable Frequency Drive (VFD) and multi- speed starters. Variable Frequency Drives are not usually listed as RVSs, although they may provide reduced starting inrush and disconnect spikes when configured to ramp-up and down at controlled rates. Autotransformer type starters have been the most popular since they can be used with all standard motors and without spe- cial windings. The starter consists of a three phase auto-transformer (usually with three standard reduced voltage taps 50 percent, 65 percent, and 80 percent), three contac- tors, a time delay relay and an overload relay. This is called a closed transition starter. Care must be exercised in the use of this type of starter since the in-rush current of the transformer may meet or exceed the motor in-rush across the line, depending upon system voltage, motor horsepower and motor starting code (refer to the NEC). It is usually the most expensive of the reduced voltage types and requires the most installation space. Wye-Delta starters take their name from the manner in which the motor windings are connected the windings are con- nected in Wye to start the motor and then reconnected in Delta to run. Please note that these require a specially wound motor. Solid state reduced voltage starters (Figure 6-11) limit in-rush current when starting an induction motor. This type of starter electronically controls power semi- conductors to gradually increase the volt- age applied to a motor when starting. This in turn limits the starting torque surge cre- ated by the in-rush current. The result of limiting the torque surge is a smoother start and decreased equipment downtime due to shock and vibration problems. Solid state reduced voltage starters can also control the deceleration rate of the motor. (This is typically ordered as an option.) The starter gradually reduces the voltage applied to the motor to bring it to Controls for Submersible Pumps 76 Figure 6-11: Reduced voltage starters (RVS). (Courtesy: SJE Rhombus). Chapter 6 2/2/06 4:36 PM Page 76 a stop. This reduces surges associated with abrupt motor stopping. Bypass contactors are used in most solid state reduced voltage starter applications. The contactor is energized upon receiving an up to speed signal from the SSRVS. The motor current then bypasses the starter thus reducing heat build-up through the semi-conductors. The bypass contactor will be de-energized with a call to stop signal and the starter will control the ramp down of the motor if equipped with a controlled stop feature. Variable Speed Controllers Variable speed controllers are normally used to maintain pump flow rates approxi- mately equal to rate of flow entering the lift station (see Chapter 7). Variable Frequency Drives (VFD) Variable frequency drives should only be applied to conventional three phase motors. They achieve speed regulation by control- ling frequency, usually between 30 and 60 Hertz. A transducer, sensing discrete changes in wet well level, sends a signal to the variable frequency controller to raise or lower the frequency, thus speeding up or slowing down the motor. Variable speed controllers require an analog signal to prop- erly vary the speed of the pump with the wet well level. Choice of the level control system, selected below, is critical. Cable lengths should be minimized to reduce volt- age spikes. Multi-Speed Multi-speed starters are available in several types, but the two speed starter for a one winding constant or vari- able motor is the most common in pump applications. The two-speed starter consists of two magnetic starters, each with over- load relays and auxiliary contacts to pre- vent both starters from being energized simultaneously. The level control system must be designed to start two speed motors in the desired sequence with the limitation that a motor running at high speed must be stopped before restarting at low speed. For automatic operation, this is usually accom- plished by the addition of compelling relays in the control circuit. Because six motor leads are required, it is not commonly used for submersible applications. Level Control Systems There are several widely used devices available for wet well level control: float switches, pressure activated diaphragm switches, bubbler (air) systems, electrode level sensors, ultrasonic transducers, pres- sure transducers and resistance varying sensors. Each of these control devices has its own advantages in submersible pump applications. Selecting one over another depends on the particular application. Float Switches The most popular and often less expen- sive level control system for submersible pump stations is the encapsulated float switch. It is suspended in the wet well at the desired actuation level. Simplex pump systems (Figure 6-12) often use three switches one for On, one for Off and a third for Alarm. Or, they may Controls for Submersible Pumps 77 Figure 6-12: Simplex pump with three-float switch control. Chapter 6 2/2/06 4:36 PM Page 77 use a single differential float switch (Figure 6-13) for On-Off control. Multi-pump systems with a common OFF level typically requires three or more float switches, common stop, lead pump start, and a lag/alarm float switch. The Lag/Alarm float switch, when activated, starts the sec- ond pump (if required) and sounds the liq- uid level alarm. Many other combinations can be used if the application involves sep- arate alarm activation, off levels, four or more pumps, duplex wet wells, etc. Three float switches are required for a standard duplex system the lowest for pumps Off, the next highest for lead pump On, and the third at a still higher level for lag pump On and the alarm function. In a typical pump down application the float switches are normally open. As the wet well level rises, the OFF float switch closes but no other action occurs. As the level continues to rise, the lead ON switch closes, completing the pilot circuit to start the lead pump. When the lead pump low- ers the level and the lead On switch opens, no action occurs due to a latching contact which keeps the circuit energized until the level is lowered to the point at which the pump OFF switch opens. Float switches are maintained at the desired level by clamps/straps, (mounted to a pipe) or suspended floats utilizing inter- nal weights or an external weight attached to the cable. The float switch housing mate- rials include PVC, Polypropylene or Polyurethane foam. This provides floata- tion, seals the unit against the entry of water, and maintains electrical integrity. In the differential float switch, a single switch provides both ON and OFF actua- tion at different levels. Most switches of this design have a minimum differential level of approximately 6-inches and a max- imum of 30-inches. Float systems are relatively simple to Controls for Submersible Pumps 78 Figure 6-13: Simplex pump with a wide angle (differential) pump switch control. Figure 6-14: Duplex pump with four narrow angle float control system. Chapter 6 2/2/06 4:36 PM Page 78 maintain (Figure 6-14). They can be replaced easily, and highly skilled person- nel are not required for troubleshooting. Diaphragm Type Switches Diaphragm type switches are a special form of pressure switch. They consist of a housing containing a set of spring-loaded contacts, snap-action contacts, which are activated by a flexible diaphragm made of a suitable elastomer. The switch must be mounted in a fixed position in the wet well approximately 10 to 12 inches below the desired actuation level, since this amount of water pressure is required to achieve the snap action in most designs. The electrical cord on these switches also contains a small diameter plastic tube, which is required for venting of the switch interior to atmosphere so that predictable actuation levels can be maintained. Because of the possibility of punctured diaphragms, plugged or pinched breather tubes and a history on unreliabil- ity, diaphragm switches are less commonly used than float switches. This type of switch provides a fixed dif- ferential usually 10 to 12 inches between switch open and switch closed positions. This differential often can be uti- lized to advantage in specific applications. While some designs provide greater or smaller differentials, none of the switches are adjustable. Pressure activated diaphragm switches, used in some grinder pumps to control pumps and alarm operators, perform the same function as float switches. They may be remotely located in the control panel or pump housing, and respond to air pressure trapped in an inverted bell. They must breathe to atmosphere to obtain reference pressure. There are no moving parts in con- tact with sewage. Bubbler (Air) Systems Bubbler or air systems are level controls which sense water level by creating a back pressure in a pneumatic system which is proportional to the depth of water sub- merging the end of the bubbler tube. An air supply is usually provided by an air compressor with a small receiver, a pres- sure regulator to control downstream pres- sure, a flowrator (needle valve in graduat- ed flow tube), and a differential pressure regulator (across flow tube, inlet to outlet). Pressure switches connected to the bub- bler tube, on the discharge side of the flow tube, are used to set desired actuation points for pump start, stop, and alarms. Pressure gauges are graduated in feet or inches of water as desired. They are con- nected to the bubbler line and provide a continuous visual indication of water level. Switch gauges are available which combine both gauge and switch features; there are two set points per unit which can be read- ily adjusted from the front of the instru- ment. Since a controlled air supply is critical for proper operation of a bubbler system, it may be desirable to use duplex alternating air compressors with a low air supply alarm to ensure system reliability. Some available systems use vibrating reed or diaphragm- type compressors; these have no receiver and run continuously. Although less costly than piston-type units with receivers run- ning cyclically, this type is less reliable. The air receiver also has the advantage of pro- viding a volume of stored air, which can both maintain airflow during brief power outages and provide necessary volume for purging. Another feature considered necessary in a quality bubbler system is the differential pressure regulator installed across the flow tube (also called a minirator). A bubbler system depends upon a constant, low rate of flow (cubic inches per hour) to accurately reflect water level through back pressure in the air system. As water level increases and decreases, the differential pressure across the needle valve in the flow tube changes, causing the flow rate to change. The dif- ferential pressure regulator compensates for the change to maintain a constant airflow through the needle valve. It is recommended that the bubbler tube be kept as small as practical; most designs are calibrated for use with 1/4-in. inside diameter (I.D.) tubing. Since airflow rates are low, the best results are obtained when Controls for Submersible Pumps 79 Chapter 6 2/2/06 4:36 PM Page 79 individual air bubbles rather than a stream are seen rising from the end of the tube. Such flow rates are sufficient to exclude water or debris from entering the tube and possibly causing a system malfunction. Tubes larger than 1-in. I.D. permit water to rise inside the tube, resulting in the deposit of grease and scum on the inner wall eventually accumulating to block the flow of air and producing a system malfunction. Effective purging can be accomplished with small air receivers at 50 psi and con- stant 1/4-in diameter tubing. Manual push button purge valves are available. They per- mit the high-pressure air to enter the bub- bler tube directly, and at the same time block off the low-pressure line to prevent damaging the equipment which regulates the normal bubbler airflow. Some bubbler systems utilize a pressure responsive transducer instead of switches for pump start-stop signals and alarms. The transducer output is connected to a series of solid state set point circuit boards which provide a relay output for initiating the desired function. The set-point cards can be adjusted in the field and usually have LED indicators to show the ON state. These systems have a variety of sophis- ticated options available, and are subject to the same skilled maintenance requirements as other solid state electronic controls. Solid-state system costs range from the same to higher when compared to electro- mechanical systems. Pneumatic systems cost for either type is the same and all types of bubbler systems generally require exten- sive maintenance. The bubbler system is inherently explosion-proof because no elec- trical equipment is installed in the wet well. Electrode Level Sensing Systems Electrode systems are the least prevalent of the liquid level systems used in sewage systems. They use a series of specialized relays, which rely on small electrical cur- rents (milliampre level) flowing in the liq- uid from one metallic electrode to another, or to ground. When current flows, the relay is de-energized. One relay is required for each function a pump On-Off function requires one relay, an alarm level requires another, etc. Due to the nature of sewage, standard electrodes have not proven satisfactory. A system using a flexible bulb and a clean water solution has been devised, consisting of a 1-1/2 or 2-in standard pipe, a flexible neoprene bag, and an electrode holder. The neoprene bag is secured to the lower end of the pipe and the electrode holder to the upper end, above the highest water level. Suspended type electrodes are attached to the electrode holder and installed inside the pipe. This assembly is then installed in the wet well and filled with a solution of clean water and bicarbonate of soda (ensuring good conductivity) to the level of the ground electrode. This system is limited by the volume of the liquid contained in the flexible bag, which holds only a volume of liquid suffi- cient to fill a 1-1/2-in. pipe to a maximum length of eight feet. Available electrode hold- ers are constructed to NEMA standards but are not designed for the environment of a sewage wet well. Special care is required during installation to ensure that the hold- er is watertight. However, it is impossible to guarantee that the electrical assembly will remain watertight, especially if submer- gence occurs during a power outage. Electrode systems require the same skill level for maintenance as float switch sys- tems, but are higher in cost due to the spe- cial relays. Ultrasonic Transducers Ultrasonic level detection systems are among the most sophisticated liquid level controls. While the same basic components and options offered by other systems are available, a different method is used to determine liquid levels. Ultrasonic systems use high frequency sound waves. An ultrasonic transmitter is mounted in the wet well and mounted ver- tically downward. Sound waves strike the water surface and bounce back to the trans- mitter/detector, which measures the length of time required for the waves to travel. This time differential is converted by Controls for Submersible Pumps 80 Chapter 6 2/2/06 4:36 PM Page 80 solid state electronic circuitry typically to an analog 4 to 20 milliamp output signal, which is proportional to the wet well level, to solid state electronic controllers. The input signal can be adjusted to actuate a relay at any desired wet well level. Contacts on the relay are then used to activate the magnetic starters and alarms. Ultrasonic systems are relatively expen- sive but they generally require far less maintenance than any other monitoring device. They do require regular mainte- nance to insure reliability and they are quite easy to troubleshoot by a skilled sys- tems technician or electrician in the event of malfunction. Pressure Transducers Pressure transducers are either mounted in the wet well or connected to a bubbler tube. In both cases, the transducer senses the hydrostatic head of the wet well and typically converts it to an analog 4 to 20 milliamp signal. The limitations of mainte- nance and service are the same as described for the ultrasonic system. They may be less expensive than the ultrasonic type. Hazardous Area Applications Industrial and municipal wet well lift sta- tions are now quite often classified as haz- ardous locations. Defined by OSHA as class I division I groups C,D. When they are so classified, the following factors must be considered. Of the level control systems discussed above, the bubbler system is inherently intrinsically safety, since it has no electri- cal energy in the wet well itself. The other systems require both electrical wiring and installation within the wet well. The wet well level control equipment must be installed in a non-hazardous area or in an explosion proof enclosure. When the area is classified as a hazardous duty location, the use of float switches, electrodes and transducers are commonly used in haz- ardous locations in conjunction with intrin- sically safe relays. In the case of electrode systems, intrinsically safe relays are avail- able which do not require additional intrin- sically safe couplers. The term intrinsic safety as applied to electrical or electronic apparatus means simply that any failure of a component or wiring cannot produce a discharge of suffi- cient energy to create a spark or generate enough heat to ignite an explosive atmos- phere. Intrinsic safety as applied to lift stations produces special installation problems. The NEC requires that wiring from an intrinsic device in a non-hazardous area to a sensor in a hazardous area pass through a conduit equipped with a sealed fitting so that there is no passage of hazardous gases into the non-hazardous area. A sealed fitting is a standard electrical conduit fitting which is filled with a liquid epoxy after installing the wires. The epoxy cures after a brief period to form an impervious barrier to gases. Non-hardening compounds are also avail- able. The NEC also requires that power wiring and intrinsic wiring be separated, which for practical purposes means separate conduits for pump power leads and for level con- trols. To facilitate maintenance, junction boxes are used to make the connection between the level sensor and wiring from its relat- ed intrinsic coupler. A separate intrinsic coupler is used for each float switch except for lead pump ON-OFF switches, which can utilize a latching type coupler. This junc- tion box should not be installed in the wet well. NEMA-rated junction boxes (see the end of this chapter) are not designed for a wet well environment with the exception of NEMA 6 and 6P (rated as submersible), which both have limitations as to the depth and length of time the box may be sub- merged. Conduit and sensor connections provide a possible entry of water even under the best of conditions. NEMA 4 and NEMA 7 junction boxes are sometimes specified but not recommend- ed for installation in a sewage wet well. Both of these types can become filled with moisture in a saturated atmosphere and result in system malfunction. If such instal- Controls for Submersible Pumps 81 Chapter 6 2/2/06 4:36 PM Page 81 lations cannot be avoided, it is suggested that the junction box be filled with a water- resistant grease after the wires are con- nected to the terminal strip. Wire-nutted connections wrapped with self-vulcanizing tape or waterproof wire nuts are alternative methods. Note that a NEMA 7 junction box is not required with intrinsically safe wiring since, by definition, a wiring fault cannot ignite an explosion. Operation Sequences It is common in lift station design to pro- vide a total pumping capacity greater than the anticipated peak flow. In duplex sta- tions, for example, one pump is usually capable of handling maximum anticipated flow, triplex stations may be designed such that no more than two pumps are required to handle maximum flow, etc. This makes it necessary to provide additional circuitry in the control panel to interface with the level sensors for alternating the pumps and starting the back-up pump(s). In duplex stations, the most common technique is to automatically alternate the pumps and provide a lead-lag circuit. The normal sequence is as follows: Water level rises to the lead pump On level; the pump starts and lowers the level to the pump(s) Off point; the pump stops and automatic alternation indexes to position the second pump as the lead pump for the next cycle. If the lead pump starts and the water level continues to rise to the lag pump On level, the second pump will then start and both pumps will operate together until the water level is lowered to the pump(s) Off level. If the lead pump fails to start for some rea- son, the lag pump is designed to begin oper- ating. A typical schematic showing the Controls for Submersible Pumps 82 Figure 6-15: Typical alternating circuit design. Chapter 6 2/2/06 4:36 PM Page 82 interconnection of alarms and level sensors is shown in Figure 6-15. A similar sequence using multi-pump alternators can be utilized for stations with three or more pumps. As the level rises incrementally after the lead pump is start- ed, additional pumps are brought on in sequence until the level is lowered to the Off point and the alternator indexes to the next pump in the sequence. Alternation may also be accomplished by manual selector switches or time clocks. Time clock alternation is automatic, but instead of alternating pumps at the end of each pump cycle, the alternation occurs in increments of weeks, days, hours, or min- utes as predetermined by the time clock. Manual alternation is accomplished by a selector switch which fixes the lead-lag sequence until the maintenance personnel physically change the switch to select a new sequence. The purpose of all alternation techniques is to distribute wear evenly on all pumps and to ensure that a pump does not become inoperable due to idleness. Auxiliary Equipment Alarm Systems Alarm systems are generally required for all lift stations. They may vary from a sim- ple high water level alarm to a multi-point annunciator. The most common and necessary is the high water alarm. It is recommended that the high water alarm be coincident with the last lag pump in the sequence for multi- pump stations. When a pump station is designed as discussed above, as the level rises to call for a lag pump, failure of the lead pump or pumps is a probable reason. If the alarm is activated by a separate level sensor, it is suggested that the level for acti- vation precede the On level for the last pump. A redundant Off level with alarm has become a popular requirement in applica- tions where the wet well is classified as a hazardous location. The NEC has often been mistakenly interpreted as requiring explosion-proof motors or pumps installed in such wet wells; in practice, standard sub- mersible units may be used as long as the lowest level maintained is above the top of the pump. To guarantee submergence in such appli- cations, an additional level sensor is installed to activate slightly below the nor- mal Off level. This level sensor is used in most cases to activate an alarm and to deac- tivate the pump pilot circuit. The control system must be designed to eliminate the possibility of manually running the pump with the Hand-Off-Automatic (HOA) switch, thus ensuring guaranteed submer- gence. In some states and counties, you may eliminate the need (cost) of an explosion proof pump with guaranteed submer- gence. Another important accessory is the pump failure alarm, which uses as a sensor either a pressure switch installed in the valve chamber on the individual pump discharge just ahead of the check valve, or a limit or tilt switch installed on the check valve lever arm. If the pressure switch or check valve switch fails to open when the related pump is activated, and alarm circuit is energized after a preset time delay and the related pump is shut down. Since any pump fail- ure, electrical or mechanical, results in the inability to move the liquid, this alarm pro- vides a first indication of trouble. A power failure alarm may also be required, particularly if the station is equipped for operation by a portable gen- erator in the event of a power failure. A phase monitor is generally used as a sen- sor in three phase systems and a pneumat- ic time delay relay in single-phase systems. Battery-powered alarm devices are required if local alarms are to be activated. If remote self-powered alarms are used, a dry contact opening or closure can be provided by the power fail sensor. Seal failure alarms and motor heat sen- sor alarms are sometimes specified. Most manufacturers do not require an audible alarm for warranty purposes. Visual indi- cation of the seal failure condition and Controls for Submersible Pumps 83 Chapter 6 2/2/06 4:36 PM Page 83 inclusion of the motor heat sensor in the pump starter circuit is usually adequate to satisfy warranty requirements. Other alarms which may be specified are motor overload trip, station flood (failure of check valve to close), low air supply (for bubbler systems), circuit breaker trip, etc. Local alarm devices can be both audible and visual. The preferred audible alarms are either a bell or a horn. Visual alarms are usually a flashing light. These units should be weather proof since they must be installed in exposed locations to be seen or heard. Multiple alarm systems should have an indication light on the control panel and a latching circuit with a reset switch for each alarm. Most remote systems require dry contact inputs from the control panel alarm circuit either normally open or normally closed, depending upon the particular device used. If only one signal is to be transmitted from a panel with multiple alarms, then a sum- ming relay is added in the control panel to provide a general alarm single input to the telemetry system. Telemetry Systems A variety of telemetry systems are avail- able to communicate an alarm condition to a desired remote location, such as the sewage plant or a police station. These sys- tems range from simple single signal devices to complex systems. The transmit- ter portion is usually installed in or near the control panel and may have its own bat- tery back up power system. Such devices as tape dialers, digital communicators, tone systems and voice-synthesized computers are available. Additional Control Components A completely integrated control panel may also contain a number of other elements required for proper operation of the station. Power distribution panels (circuit breaker Controls for Submersible Pumps 84 Figure 6-16: Examples of different enclosure types. (Courtesy of SJE Rhombus). Chapter 6 2/2/06 4:36 PM Page 84 Controls for Submersible Pumps 85 In Hazardous Locations, when completely and properly installed and maintained, Type 7 enclosures are designed to contain an internal explosion without caus- ing an external hazard. Type 8 enclosures are designed to prevent combustion through the use of oil-immersed equipment. Type 9 enclosures are designed to prevent the ignition of combustible dust. Type 7 - Enclosures constructed for indoor use in hazardous locations classified as Class I, Division 1, Groups A, B, C, or D as defined in NFPA 70. Type 8 - Enclosures constructed for either indoor or outdoor use in hazardous locations classified as Class I, Division 1, Groups A, B, C, and D as defined in NFPA 70. Type 9 - Enclosures constructed for indoor use in hazardous locations classified as Class II, Division 1, Groups E, F, or G as defined in NFPA 70. *Note: Due to the large number of variable factors involved with explosive proof enclosure selection, direct contact with the enclosure manufacturer is recommended to ensure the proper enclosure is selected for your specific application and hazardous rating classification. Figure 6-17: NEMA enclosure types. National Electrical Manufacturers Association (NEMA Standard 250) and Electrical and Electronic Mfg. Association of Canada (EEMAC) Enclosures are intended for indoor use primarily to provide a degree of protection against contact with the enclosed equipment or locations where unusual service conditions do not exist. Enclosures are intended for indoor use primarily to provide a degree of protection against limited amounts of falling water and dirt. Enclosures are intended for outdoor use primarily to provide a degree of protection against windblown dust, rain, and sleet; undamaged by the formation of ice on the enclosure. Enclosures are intended for outdoor use primarily to provide a degree of protection against falling rain, and sleet; undamaged by the formation of ice on the enclosure. Enclosures are intended for outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, and hose directed water; undamaged by the formation of ice on the enclosure. Enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water, and hose directed water; undamaged by the forma- tion of ice on the enclosure. Enclosures are intended for use indoors or outdoors where occasional submersion is encountered, limited depth; undamaged by the formation of ice on the enclosure; resists corrosion. Enclosures are intended for indoor use primarily to provide a degree of protection against dust, falling dirt, and dripping non-corrosive liquids. Enclosures are intended for indoor use primarily to provide a degree of protection against dust, spraying of water, oil, and non-corrosive coolant. Underwriters Laboratories Inc. (UL 50 and UL 508) Indoor use primarily to provide protection against contact with the enclosed equipment and against a limited amount of falling dirt. Indoor use primarily to provide protection against limited amounts of falling water and dirt. Outdoor use to provide a degree of protection against windblown dust and windblown rain; undam- aged by the formation of ice on the enclosure. Outdoor use to provide a degree of protection against falling rain; undamaged by the formation of ice on the enclosure. Either indoor or outdoor use to provide a degree of protection against falling rain, splashing water, and hose-directed water; undamaged by the formation of ice on the enclosure. Either indoor or outdoor use to provide a degree of protection against falling rain, splashing water, and hose-directed water; undamaged by the formation of ice on the enclosure; resists corrosion. Indoor or outdoor use to provide a degree of protec- tion against entry of water during temporary sub- mersion at a limited depth; undamaged by the external formation of ice on the enclosure; resists corrosion. Indoor use to provide a degree of protection against dust, dirt, fiber fryings, dripping water, and external condensation of non-corrosive liquids. Indoor use to provide a degree of protection against lint, dust seepage, external condensation and sprayng of water, oil, and non-corrosive liquids. Canadian Standards Association (Standard C22.2 No. 94) General purpose enclosure. Protects against acciden- tal contact with live parts. Indoor use to provide a degree of protection against dripping and light splashing of non-corrosive liquids and falling dirt. Indoor or outdoor use; provide a degree of protec- tion against rain, snow, and windblown dust; undamaged by the external formation of ice on the enclosure. Indoor or outdoor use; provides a degree of protec- tion against rain and snow; undamaged by the external formation of ice on the enclosure. Indoor or outdoor use; provides a degree of protec- tion against rain, snow, windblown dust, splashing and hose-directed water; undamaged by the external formation of ice on the enclosure. Indoor or outdoor use; provides a degree of protec- tion against rain, snow, windblown dust, splashing and hose-directed water; undamaged by the external formation of ice on the enclosure; resists corrosion. Indoor or outdoor use; provides a degree of protec- tion against the entry of water during temporary submersion at a limited depth; undamaged by the external formation of ice on the enclosure; resists corrosion. Indoor use; provides a degree of protection against circulating dust, lint, fibers, and flyings; dripping and light splashing of non-corrosive liquids; not provided with knockouts. Indoor use; provides a degree of protection against circulating dust, lint, fibers, and flyings; seepage and spraying of non-corrosive liquids, including oils and coolants. Enclosure Rating Type 1 Type 2 Type 3 Type 3R Type 4 Type 4X Type 6 Type 12 Type 13 WHAT ARE THE TYPES OF COMPONENTS USED FOR INDUSTRIAL CONTROL PANELS? Chapter 6 2/2/06 4:36 PM Page 85 load centers) may be included to provide the necessary short circuit protection for addi- tional equipment in or near the station. Panels may include time clocks and contac- tors to provide automatic cycle operation of vent blowers. There may be starters and con- trol circuitry for auxiliary equipment. Other control components may include elapsed time meters, lightning arrestors, cycle coun- ters or other components. Another device commonly used in con- trol panels installed in exposed locations is the anti-condensation heater.. This heater maintains the air temperature in the panel 4 to 6 degrees F. above the ambient tem- perature to prevent condensation of and any resulting deterioration of the electrical equipment. Forced air heaters work the best to circulate interior air. The control manufacturer will help deter- mine which optional controls are needed for a particular application, and will then fabricate the control panel to this specifi- cation. All panels should be built in accor- dance with NEC requirements. Control Panel Enclosures Enclosure manufacturers make a variety of electrical enclosures for installing the type of equipment discussed above (Figure 6-16). These enclosures are available in a variety of material (usually steel) and sizes to accommodate any set of conditions like- ly to be encountered. Most enclosures are required to meet one or more of the ratings indicated in the accompanying charts (Figure 6-16 and 6- 17) and should be chosen for suitability and use in specific environments. It should be noted that acceptance by one authority may not be acceptable to others. Installation of equipment on enclosures may require der- ating of the enclosure. Some of the more common NEMA rat- ings are listed in Figure 6-17. All of these enclosures may be fitted with an inner door for mounting pilot lights, switches, gauges, elapsed time meters, and other components. With an inner door unit, no live parts are exposed with the outside door open and there is a barrier between the operator and all live components. This type of construction is also desirable in out- door applications to discourage vandalism. Please note that the above list is not inclu- sive. Other types of enclosures are available for other applications. Conduit seal off fittings must be locat- ed between the wet well and the control panel to prevent gas migration into the con- trol panel enclosure. Failure to prevent gases from entering the panel is dangerous and will reduce component life and the integrity of the system. Grinder Pump Panels Most grinder pumps are used in low pres- sure sewer systems for one or more single- family dwellings. They are simplex units with single-phase motors. These motors require external start and/or run capacitors (if not integrated into the pump), plus a con- trol relay that must be installed in the con- trol panel. However, if only run capacitors are used, a control relay is not necessary. Separate overload relays for motor overload protection are required. Motor heat sensor cut-out (a thermal switch in motor winding) and seal-fail indi- cation options, if not integral in the motor winding, are offered by most manufactur- ers. Specific component additions to the control system are needed to utilize the optional equipment properly. Some grinder pump manufacturers offer a delay timer option so that the pump run cycle can be extended below the Off float level and permit the pump inlet to break suction. This is done both to clear any floating solids from the liquid surface and to ensure that no solid such as wood, plastic or other difficult-to-chop material is left in the primary cutting portion of the pump to cause jamming on the next cycle. Reversing contactors have also been used for the same purpose. In this design, the direction of rotation of the pump is reversed at the end of each cycle to clear the pri- mary cutters of solids. Many simplex grinder pump installations, Controls for Submersible Pumps 86 Chapter 6 2/2/06 4:36 PM Page 86 while serving individual dwellings, are municipally owned and maintained. This means putting the control panel on the exte- rior of the dwelling for service reasons, which necessitates outdoor weather-resis- tant enclosures (NEMA 3R, 4 or 4X styles). Larger grinder pumps are available with 3 and 5 HP single phase motors and 3, 5 and 7-1/2 HP three phase motors. These pumps are most commonly used in duplex lift station applications. The same control parameters apply as presented in this chapter for single and three phase control panels. Controls for Submersible Pumps 87 Chapter 6 2/2/06 4:36 PM Page 87 88 Chapter 6 2/2/06 4:36 PM Page 88 Users may achieve increased flexibility, enhanced performance, energy savings, and automatic adjustment to varying head and flow by using a properly designed variable speed pumping system. Some pumping applications may challenge a constant speed systems ablity to operate within the Preferred Operating Range (POR). Preferred and Allowable Operating Range (AOR) are illustrated in Figure 7-1. Variable speed pumping can provide a suit- able design alternative to address the con- cern of maintaining pump operation with- in the POR by adjusting speed as system load changes. It is the purpose of this chapter to describe each contributing component of the variable speed pumping system, how it interacts with other components and to provide the reader with knowledge to prop- erly evaluate the advantages and disad- vantages of applying such a design to sub- mersible pumping equipment. 89 Chapter 7 Variable Speed Pumping There are numerous considerations and design criteria for variable speed pumping systems. The intent of this chapter is to provide designers and end users with design guidelines about variable speed pumping and variable frequency drives to make an informed decision about a specific application. It is then suggested that the drive, pump, and motor manufacturers be consulted to coordinate the use of the individual equipment for each application. Figure 7-1: Illustrations of Preferred and Allowable Operating Ranges. Chapter 7 2/2/06 4:38 PM Page 89 Means of Achieving Variable Speed There are numerous methods to enable a pumping system to operate at variable speed. These methods use the application of either mechanical or electrical equip- ment components specifically designed for such results. Mechanical means of variable speed are not practical in the context of sub- mersible pumps since a submersible pump is a close coupled machine where the pump and motor are an integral unit sharing the same shaft. Therefore, the most reasonable and common methods of achieving variable speed in a submersible pumping system are through the use of two speed motors or variable speed electrical drive components that are mounted away from the actual pump setting. The use of a two speed motor allows the flexibility of operating at low flows and head during off peak conditions and at high flows and heads during peak conditions. This provides less frequent ON/OFF cycling of the pumps which, in turn, improves con- sistency of pump system operation. Two speed, submersible pump performance may be illustrated in the same manner as con- stant speed pumps or mathematically pre- dicted by use of the Pump Affinity laws *(Note 1). Figure 7-2 shows a two speed pump curve and its relationship to the sys- tem curve. The pump system performance will vary with every application based on the slope of the pump performance curve and its relationship with any specific sys- tem curve. Therefore, this analysis is nec- essary for every application considered for multi or variable speed system perfor- mance. The use of a VFD allows the speed of the motor to be varied by controlling the volt- age and frequency. As pump speed changes, the pump curve shifts, creating a new inter- section with the system head curve. Figure 7-3 illustrates performance curves for the same impeller at different speeds. Variable Speed Pumping 90 Figure 7-2: Typical two speed pump curve. *Note 1: The affinity law relationships define the manner in which head, flow rate, horsepower, and NPSH vary in a centrifugal pump with respect to speed or impeller diameter changes. Refer to Appendix. Chapter 7 2/2/06 4:38 PM Page 90 Advantages of Variable Speed Pumping With the appropriate application, the use of variable speed pumping assists the designer in matching inflow and reducing the required wet well size (storage). This may provide savings in over-all initial cap- ital cost. Varying the speed of the pump can improve system operational flexibility and may result in: energy savings, less ON/OFF cycling, less wear and tear of the mechanical and electrical components, improved power factor, lower demand charges. These may be accomplished by regulat- ing flow through the system for extended periods of time within the flow profile of the pumping system. Applications that are common candidates for evaluating the advantages of variable speed pumping are systems with wide rang- ing inflows that have limited volume for storage such as wastewater lift stations, influent pumps at treatment plants and storm water stations. Although an analysis should be made between simple use of set(s) of small pumps for average flow and large pumps for peak flows, variable flow pumping may provide more preferable management of the overall flow profile through the installation. A collection sys- tem lift station pumping into a pressurized force main is an example of pump(s) oper- ating against a varying head pressure. The use of a constant speed system would cause the pump to run up and down its impeller curve causing mechanical loads to wear the rotating and sealing elements. A properly applied variable speed pump and drive sys- tem would simply react to the changing conditions. Another example of this situa- tion is pumping into a discharge that has more than one conveyance or piping sys- tem attached to it. A successful evaluation of a variable speed system on any specific application will provide the user with reduced life cycle costing *(Note 2). Variable speed should render improved system performance through consistent flow management by reaction to system head pressure that can Variable Speed Pumping 91 Figure 7-3: Typical variable speed curve. Chapter 7 2/2/06 4:38 PM Page 91 reduce the effects of wear on all compo- nents and supply a more balanced hydraulic system. In this case, a balanced hydraulic system is one that provides the user with better flow conveyance while sus- taining the pump within its preferred oper- ating range. Analysis of the manufacturers recommended or preferred operating range on the system curve and the proper selec- tion of all of the components in a VFD sub- mersible pumping system is critical to achieving these results. System Considerations The very best way for the system design- er or end user to obtain optimal efficiency and effectiveness in any variable speed environment is to closely coordinate system design with the drive and submersible pump manufacturer. Figure 7-4 illustrates how the variable frequency drive achieves optimal performance by operating the motor at the precise speed to satisfy the sys- tem demand. Power saving relationships in the terms of operating costs and utility demand charges can be compared to theo- retical and constant head performance. The variable speed pumps performance curve maintains its relative shape, but shifts up and down the system curve as speed changes. This is an illustration of the affin- ity laws and allows a wide range of head- flow combinations. The slope of the system curve reflects the actual changes in the flow with each change in head. The pump man- ufacturer should be consulted for specific information about limiting minimum and maximum flow conditions across the speed range for individual and parallel pump operations. It is possible that the pumps rotational speed can be reduced to a level such that Variable Speed Pumping 92 *Note 2: The Life Cycle Cost (LCC) of any piece of equipment is the total lifetime cost to purchase, install, operate, maintain, and dispose of that equipment. For methodology refer to the Hydraulic Institute or the U.S. Department of Energy (D. O. E.). Figure 7-4: Illustration of how the variable frequency drive achieves optimal performance. Chapter 7 2/2/06 4:38 PM Page 92 its shutoff head is equal to the systems sta- tic head thus rendering the flow to zero. At shutoff head, the pumped media will recir- culate within the casing and will produce cavitation and high radial forces. This caus- es shaft deflection beyond the manufac- tures limits and leads to premature bear- ing and seal failure. This occurrence is unique for every pump and station design combination and the minimum speed must be calculated for each application to avoid operation at shutoff head. Variable frequency drives must be set to prevent a pump from operating below a prescribed minimum speed. Further more, liquid velocities below 3 feet per second (higher for liquids containing high grit or sand concentrations) will no longer suspend solids and the discharge line or pump may clog. VFDs are generally capable of a wide speed range and this rarely limits the oper- ating range for the system. Conversely, the allowable POR of pumps in the system will create limits within the AOR of the VFD. A pumps operating speed range for a com- mon lift station submersible (i.e. three or four inch discharge size or 100 to 1,200 GPM) can be approximately 70 (42 HZ) to 100 percent (60 HZ). For larger pumps such as those used in large main pump stations, influent structures to treatment plants, raw water intake or makeup water (i.e. six inch discharge and larger or flow well above 1,200 GPM) the operating speed range can be approximately 50 (30 HZ) to 100 percent (60 HZ). It is important that the relation- ship between pump speed and the specified total system performance be understood by the designer since it will affect pump oper- ational life. The minimum speed of a sub- mersible pump is dependent on the mini- mum flow of the system. As illustrated in Figure 7-4 (which is a specific installation), station flow is 0 percent when the pump speed is approximately 40 percent. This curve would be different for each specific hydraulic design. This is another important performance measure for which the pump manufacturer should be consulted. Wet Well Considerations The application of variable speed pump- ing has several implications on the wet well. For an application in a new wet well design, the use of variable speed pumping may allow for a smaller wet well. This is because a well-designed variable speed pump control system, at least in theory, can eliminate the need for conventional fill/draw operation of on/off pumping, thus reducing the active wet well volume. Practical experience has shown that even a sophisticated variable speed pumping sys- tem generally requires some fill and draw capacity of the wet well. If a new station is designed for variable speed pumping, with the wet well sized for conventional fill/draw operation with on/off pumps, the end result will be a more flex- ible station that can be operated close to constant wet well levels. In addition, it can also be used as a combination of variable speed and fill/draw operation, or a conven- tional on/off design as conditions dictate. If there are equipment outages or mainte- nance issues with the switchgear and con- trols, this wet design allows a fill/draw oper- ation without compromising the number of starts/hour for which the pumps are rated. For VFD upgrades to existing pump sta- tions, the wet well capacity and geometry have already been determined by the exist- ing layout. A common mode of operation for vari- able speed pumps is to try to operate the wet well with a near constant level. The idea is that the station should process the inflow instantaneously, thus the stations outflow is equal or near equal to the actu- al inflow at any given time. This results in a constant wet well level. When a control strategy is chosen to maintain a constant wet well level, a common result in sewage applications is a build-up of greasy materi- al on the perimeter of the wet well at the operational level. As operation progresses, this build-up can become quite heavy and lead to odor problems as well as entrap- ment of other solids. In such cases, regular cleaning is strongly recommended - either automatic or manual. In the case with a Variable Speed Pumping 93 Chapter 7 2/2/06 4:38 PM Page 93 near constant wet well level, the result will be that the wet well velocities are much lower, on average, and there are few times with no flow through the station. In certain wet well configurations, operational experi- ence has shown that debris collection and the formation of rag balls have occurred. This will require a manual cleaning effort in order to maintain uninterrupted pump operation. Typically, this occurs at extend- ed low inflow periods in which the variable speed pump controller will substantially slow down the pumps, hence the velocity through the wet well is much reduced and the transportation of solids is not well developed. It is also possible to operate the wet well with some variations in the well level. This might have operational advantages based on the individual station requirements and wet well geometry. For constant speed pump- ing, or variable speed pumping with sub- stantially larger wet well level differences, we will see higher wet well velocities and longer times with no through flow as well. The higher wet well velocities prove bene- ficial in many wet well geometries because of their ability to transport solids found in the wastewater. Some wet well geometries require high- er flow rates (design flow rate or close to it) to work properly. In those cases, it is important that the pumps are brought to full operational speed for at least one cycle per 24-hour period. Motor Performance Considerations Care must be taken to ensure that the submersible pump chosen is appropriate for use in VFD operation. Induction motors may operate at higher temperatures when used with VFDs than when connected directly to utility power. This is because of the modified electrical waveform provided to the motor by the VFD. Coordinating or matching the VFD and motor system is very important to assure this added temperature will not cause premature motor winding failure. This can be avoided by considering the following common options: de-rating the motor. using an inverter duty motor (as defined by NEMA MG1 in Parts 30 or 31). more application specific cooling designs as offered by the pump man- ufacturer. De-rating a motor is a common practice used to increase the service factor. This allows the motor to withstand the increased temperature rise generated by the modified electrical waveform applied to the motor. A submersible motor is classified as a TENV (totally enclosed non-ventilated) enclosure and is recommended to be rated in accordance with NEMA Standards for such machines. Section IV of NEMA Standard MG 1-1993 is entitled Performance Standards Applying To All Machines. Parts 30 & 31 of MG-1, Section IV, include information related to the appli- cation and ultimate compatibility of the selected submersible pump, its drive, and actual installation. Part 30 of NEMA MG 1 states that rated for operation at 600v or less should not be subjected to voltage peaks that are higher than 1000v with a rise time that is less than 2 microseconds. Unless suitable protection circuitry is provided, motors connected to 480v IGBT (isolated gate bipolar transistor)- type drives by more than 25 feet of cable will likely be subjected to peak voltages higher than 1000v at rise times not less than 2 microseconds. It should not be assumed that operation within the limits of NEMA MG 1 Part 30 is sufficient to assure prob- lem-free operation in every case. While most good quality motors will provide reli- able service if operated within these limits, it is best to check with the submersible pump manufacturer. Part 31 of NEMA MG 1 states that motors rated for operation at 600v or less should be capable of withstanding voltage peaks up to 1600v with a rise time that is not less than 0.1 microsecond. This standard is also for definite purpose motors such as sub- mersible motors. Motors meeting this spec- ification are suitable for use with 480v, IGBT-type drives in typical installations. Motor horsepower and cable lengths will Variable Speed Pumping 94 Chapter 7 2/2/06 4:38 PM Page 94 impact the rise times and peak voltages caused by VFDs. Longer motor cables and higher horsepower may require special pro- tection such as long cable filters or line reactors. Failure to take precautions can lead to premature motor failure. Current draw will differ from motor to motor, depending on the manufacturer, even though the nameplate horsepower is the same. Therefore, motor full load amper- age must be used in applying any drive to a submersible pump motor. VFD Types VFDs vary pump speed by converting the incoming line AC power to DC and then inverting it into variable frequency and variable voltage AC power to the motor. Because the synchronous speed of the motor is directly proportional to frequency, the output frequency and voltage of the VFD determine the speed of the motor. The torque required to drive a centrifu- gal pump is proportional to the square of the speed. For this reason, Variable Torque Drives should be used on submersible pumps. VFDs have been developed as a means of controlling the speed of an AC motor. Portions of a VFD are similar to DC motor drive in that they both contain a rectifier and DC buss section. The AC drive will have an inverter circuit which converts the DC voltage to an AC potential (refer to Figure 7-5). How this AC voltage is con- trolled defines the various types of VFDs available. There are three principal types of Variable Frequency Drives available with some minor variances of each type. These types are referred to as Variable Voltage Input (VVI), Current Source Inverter (CSI), and Pulse Width Modulation (PWM). Variable Voltage Input A VVI (sometimes referred to as a Variable Voltage Inverter) drive uses a sili- cone controlled rectifier (SCR) circuit (sim- ilar to a DC drive and other VFDs) on the incoming line or front end of the drive. (see Figure 7-6.) The load side of the rec- Variable Speed Pumping 95 Figure 7-5: PWM Inverter Unit Schematic. Chapter 7 2/2/06 4:38 PM Page 95 tifier circuit powers a variable voltage DC bus to supply the voltage amplitude required to maintain a constant voltage and frequency. The output stage of this drive (inverter circuit) consists of a bank of SCRs that are controlled in stages to deliv- er power to the motor. VVI drives were one of the first to be developed and are not widely used today due to several limitations. Some of these limitations are; theyre susceptible to faults due to small incoming power fluctuations, they do not perform well at very low speeds and they tend to generate a great deal of noise on the incoming power line that can affect sensitive electronic equipment or other drives. Current Source Inverter A CSI drive is similar to a VVI in that is utilizes a silicone controlled rectifier front end, variable voltage DC bus and SCR based inverter circuit. The differentiating feature of a CSI drive is a large inductor in the DC bus circuit. (Figure 7-7) The induc- tor is matched to the motor so multiple motors or smaller loads are not possible without regulation problems. Although CSI drives work well with a properly matched motor in a restricted speed range, they can be very large (due to the size of the motor matching inductor) and quite costly. There are other limitations such as poor low speed performance and limited speed range. For these reasons, they are not widely used. Pulse Width Modulation PWM is by far the most common method of varying motor speed used today. PWM drives differ from a VVI or CSI drive in that it uses diodes in the rectifier (front-end) cir- cuit and has a constant voltage DC bus. The inverter circuit is comprised of a pair of transistors for each output phase. (Figure 7-8) The output transistors are pulsed in varying widths via microprocessor based control circuitry to generate a complete cycle. Different frequencies can be achieved by changing the length of each cycle maintaining a constant voltage per fre- quency ratio with excellent regulation. The cycle pulse rate (sometimes referred to a carrier frequency) on a PWM drive varies from manufacturer to manufacturer and model to model. With lower carrier fre- quencies (2-8kHz) an audible noise may be detected when the motor is running. Higher carrier frequencies (8-15kHz) may generate more noise on the AC line and may cause the motor to run at a higher temperature. Inverter duty motors are designed to accommodate the higher carrier frequen- cies and should be considered during ini- tial system design. VFD Application Considerations Isolation Transformers, line reactors, and/or surge protection should be considered if power quality is mar- ginal Line Filters should be used in cases where there is a great distance between the motor and the VFD. This distance varies depending on motor horsepower and drive characteristics. VFDs are capable of controlling ramp up and ramp down times of a pump motor. This provides benefits Variable Speed Pumping 96 Figure 7-6: Variable Voltage Inverter (VVI). Figure 7-7: Current Source Inverter (CSI). Figure 7-8: Pulse Width Modulation (PWM). Chapter 7 2/2/06 4:38 PM Page 96 similar to a reduced voltage starter. Separate conduits should be used for each pump motor in multiple pump applications to reduce the possibility of electrical noise or cross talk. The noise generated by one drive/motor could be inductively coupled from one drive to another causing regula- tion problems and/or drive damage. Drive parameters must be set for each pumping application. Consult the pump performance curve to set the minimum and maximum operat- ing frequencies. VFDs (PWM type) can be used as phase converters in some applica- tions. Single-phase power can be applied to the drive with a three phase motor load provided the drive has been sized to accommodate the single-phase current. Some VFDs (usually smaller motor applications) are designed to accept single-phase input power only for either a single phase or three phase motor load. Energy Savings Energy savings along with process con- trol (flow regulation) are the two main rea- sons that variable speed pumping is con- sidered. The possibility of saving energy is interesting for two vastly different reasons. First, energy savings is directly associated with cost savings. Since the operational cost of a pumping system exceeds the initial equipment and installation cost by a factor as high as five to ten times over the life of the pumping system, it is normally the key driving force. The other positive aspect of energy savings is the conservation of nat- ural resources and minimization of emis- sions from fossil fuel burning plants. In order to quantify and compare energy sav- ings, we need to introduce the term spe- cific energy (E s ). Specific energy, simply stated, is the amount of energy required to pump a certain volume of liquid through a system in a specific application. Specific energy (E s ) is commonly expressed in kWh/Mg (kilowatt-hours/million gallons pumped). As can be seen from this expres- sion, there is no mention of TDH or effi- ciency. These quantities are indirectly included in the specific energy number through the energy component (kWh). The following two formulas can be used to calculate the specific energy: Specific energy can be calculated for a number of different operating points in a given pump system. It can then be com- pared based on how the pumps are con- trolled (on/off pumping, variable speed pumping, or combinations thereof), and the expected duration of each flow rate. The energy savings in wastewater pump- ing that are possible with variable speed pumping comes mainly from the reduced friction losses that result from pumping at a lower flow rate (the Head drops as flow is reduced). Some factors will counteract these savings as a result of operating at lower speeds, such as: 1. Depending upon where the best effi- ciency point of the pump lies rela- tive to its full speed operational point, the pump efficiency may climb at first, but will at some point start to drop. At greatly reduced speeds in systems with static head, the pump efficiency will be substan- tially reduced (Figure 7-9). 2. Pumping at reduced speed also results in reduced input power. Hence, lower motor loading. Induction motors can be considered to have a fairly flat effi- ciency range from 100% load and down to 25% load. At levels lower than approximately 25%, the motor efficiency will drop off substantially. 3. The introduction of a variable speed drive in itself will penalize the sys- tem efficiency with a couple of per- centage points at full speed operation. As the pumps operate at reduced speeds, the drive / motor efficiency decreases. Variable Speed Pumping 97 Energy Used (kWh) Input Power (kW) E s = = Volume Pumped (Mg) Flow (Mg/hr.) Chapter 7 2/2/06 4:38 PM Page 97 For proper evaluation and understanding of energy savings in variable speed pump- ing systems, it is of paramount importance to understand how the multitude of possi- ble duty points will fall on the pump curve as a result of the amount of static head in the pump application. For systems with no static head, (friction loss only systems) pump efficiency does not change as speed varies, i.e. if we select a pump with a full speed operational point at or close to its best efficiency point, we can safely predict that this high level of efficiency will be maintained as speed is reduced. This is true even for substantial speed reductions, such as below 50% of full speed. In systems where a high percentage of the Total Head consists of static head, the operational point will move up toward shutoff head on the pump curve when the speed is reduced. This results in a lessening of pump effi- ciency as well as the possibility of approaching duty points outside of the pre- ferred or allowed operating region. Apart from poor operational efficiencies, there is a risk of damage to the pump since opera- tion in this area often leads to vibration and an increase in radial forces on the impeller. If we divide the Static Head in a given system with the Total Head, , and A) This fraction is less than 50% (Figure 7-10), the rule-of thumb recommen- dation is that the application of a vari- able speed drive is good from an energy savings point of view. B) If the percentage of static head falls in the interval of 50% to 75% (Figure Variable Speed Pumping 98 Figure 7-9: Variable Speed Pump Curves and System Curve with 50% static head. Figure 7-10: Specific Energy (E s ) in % for a duplex pump system with 25% Static Head. Figure 7-11: Specific Energy (E s ) in % for a duplex pump system with 50% Static Head. H s H Chapter 7 2/2/06 4:38 PM Page 98 7-11), a thorough pump operation analysis and its impact on energy sav- ings is recommended. Based on the pumps selected and the duty condi- tions, variable speed pumping may or may not be suitable. C) If the static head component exceeds 75% of the Total Head (Figure 7-12), the general recommendation is that variable speed drives are not recom- mended for the purpose of saving energy. When selecting pumps and pump duty points for variable speed pumping, always select the full speed duty point well to the right of BEP for all systems with static head. This will ensure that the pump effi- ciency will initially increase at reduced speeds, which not only helps save energy, but also extends pump life and reliability. Since energy savings imply cost savings, it is important to properly analyze the costs needed to achieve the savings. These can be calculated by using specific energy for the various operational points (different flow rates) and their duration over the course of a given time period (typically a year). These savings need to be weighed against the additional costs imposed by drive procurement and installation, their maintenance and service costs, and any other associated costs. When this analysis is complete, a decision can be made about whether or not variable speed pumping is suitable for a particular application as a means for energy savings. Maintenance Issues Maintenance for any individual pumping system operating on VFDs are application specific. The operations and maintenance manual should be thoroughly read and understood so that the user can prepare an appropriate maintenance schedule tailored to the system in place. Individual O & Ms must be provided by the manufacturers of the pumps, drives, valves, and associated controls. Upon installation of the system components it is recommended the equip- ment authorized representatives be present for initial startup of the system and basic training of the system operators to assure the successful operation of the newly installed equipment. Startup assistance from each of the manufacturers represen- tatives also enables the operator and design- er to verify the system design against the equipment furnished to confirm compati- bility of the entire system and make adjust- ments, if necessary. VFDs are relatively maintenance-free since they are electrical products. Maintenance should consist of keeping the units clean, allowing for free airflow across the heat sinks, changing the air filters, and moving anything that obstructs the free flow of air into the VFD. Typically, most submersible pumps require periodic inspection for premature wear in the pump casing (volute), impeller, mechanical seals, cable and cable entry. Unusual wear in the pump components can be early warning sign that the system is not operating as originally intended. Additionally, a history of performance can be recorded to optimize the maintenance schedule to more accurately predict com- ponent failure to prevent equipment down time. Unexpected costs will be minimized with such a preventative maintenance pro- Variable Speed Pumping 99 Figure 7-12: Specific Energy (E s ) in % for a duplex pump system with 75% Static Head. Chapter 7 2/2/06 4:38 PM Page 99 gram as excessive wear on pump system components reduces the operating life of the equipment and its original efficiencies in operation. Systems operating at peak flows should assist in keeping the influent conduit and wet well relatively free from solids build up. However, if the flows are not as antic- ipated in the original design or are lower or lower for longer periods, solids build up will be of concern. This condition is not unusual but must be managed. Solids build up can restrict the suction conditions of the pump and ultimately damage the equip- ment, as well as, cause build up of sedi- ment in pipes and valves. If such a condi- tion persists, modifications must be reviewed with the designer and the equip- ment suppliers to minimize the impact of the conditions by making adjustments in the system operation. Conclusion The most common use for VFDs is to smooth out the process flow from point to point. Other benefits are reduced starts per hour, reduced wet well size and, possibly, reduced power consumption. Variable speed pump systems can also minimize the occurrence of line surges and the resultant water hammer and system transients in the upstream piping, which will lengthen the mechanical life of the pump and valve equipment. If the space for the station loca- tion is limited either physically or econom- ically, the station wet well size can be lim- ited and initial capital cost of civil works of the project reduced. Retrofitting or rehabilitating old pump stations can provide an opportunity to install larger pumps on VFDs to provide more flow, while including the flexibility to pump at low flow or at original design rates. Once again, for rehabilitation or upgrading of an existing pump station, the variable speed control option is an attractive alter- native to updating performance. There are limitations when considering this alterna- tive. Those considerations do not focus on the pump, motor or drive, but rather the structure or system in which these compo- nents are expected to operate. Care should be given to evaluating the ability of the intake structure and piping system to pro- vide adequate suction conditions. Simply stated, when changing one or more of the original design criteria of the pump station, the new or modified system design must be reconfirmed by the designer. As system and plant engineers design for variable speed operation early in the devel- opment cycle, benefits beyond energy con- servation will become apparent. Advances in motor, control and VFD technologies are also expected to increase user acceptance. New features such as greater adjustment in operating parameters will make VFDs eas- ier to use and integrate into a system. Appropriately applied and designed, con- tinued improvements in variable speed pumping technology can provide users with advantageous reductions in life cycle costing. Variable Speed Pumping 100 Chapter 7 2/2/06 4:38 PM Page 100 Lift Station Valving Selecting valves for wastewater lift sta- tions requires special consideration. Both the nature of the media and system dynam- ics must be considered. The three types of valves typically found in lift stations are check valves, shut-off valves and air valves Wastewater Valves Selecting valves for Wastewater applica- tions is similar to that of selecting pumps in that you must consider the solids con- tent of the flow when making your selec- tion. Just as wastewater pumps must be of the solids handling variety, so too must the valves. For this reason silent check valves and Butterfly Shut-off valves are not rec- ommended for lift station applications. A check valve and a shut-off valve must be installed on the discharge side of each pump, even if not required by code author- ities. The purpose of the check valve is to prevent backflow when the pump or pumps reach the off position, or in the event of power supply failure or line breaks. Use of check valves in multiple pump installations eliminates reverse flow through the non- operating pump or pumps. The shut-off valve is essential to stop system flow dur- ing pump or check valve servicing. All valves should be installed outside the wet well in a separate valve box or vault although many residential installations locate valves in the wet well. The valve and any controls are then easily accessible for servicing and, under normal conditions, there is no need to send personnel into the wet well. Check Valves Swing Check. The Swing Check valve is the oldest of the check valve designs available on the market today. Its origins can be traced back to the Roman Aqueducts. (Figure 8-1). Swing check valves utilize a 90 degree seat (position of seat relative to mating pipe) and can be provided with either an outside spring and lever, or an outside weight and lever which are used to reduce the valves propensity to slam closed when the pump is shut down and reverse flow begins. However, when used with lever and weights or springs the valve creates tremendous system head loss, which can increase the wear rate and 101 Chapter 8 Mechanical Controls and Components Properly specified and installed mechanical controls and components are important for the easy operation and maintenance of a submersible wastewater lift station. These include lift station valving for hydraulic control; access doors for easy entry and slide rail assemblies, for convenient pump disconnect, removal, and re-insertion. Figure 8-1: Swing disc check valve. Chapter 8 2/2/06 4:39 PM Page 101 decrease the efficiency of the pump. For this reason they are not recommended for lift station applications. They are normally installed in a horizontal position to mini- mize the buildup of grit and solid matter on the internal parts of the valve. Some swing check valves have an access port to remove the disc for cleaning or replace- ment without removal of valve from line. A variation of the Swing Check is the angled seat design (Figure 8-2). The valve has a much shorter disc stroke (distance from the full open to the full closed posi- tion) as it utilizes a 45 degree seat design. The valves disc stroke is 35 degrees com- pared to the 90 degree stroke of the tradi- tional swing check. The shorter stroke vir- tually eliminates the slamming problems of the traditional swing check. Since the valve does not require weights or springs and levers it also has the benefit of excellent head loss characteristics. Additional bene- fits of this type of design include a corro- sion proof disc, only one moving part, availability of both mechanical and elec- tronic disc position indication and top access for ease of maintenance. The valve does not have to be removed from the line for maintenance and can be mounted in both vertical and horizontal orientations. Ball Check. The ball check valve (Figure 8-3) utilizes a ball as opposed to a disc as its closure member. The ball is lift- ed up and away by the flow during system operation and falls back to the closed posi- tion when the pump is shut down. These valves use a corrosion-resistant ball rather than a hinged disc. The ball continuously spins by virtue of the fluid flow in the valve body and has a tendency to clean itself. Proximity switches can be mounted in some ball check valves for monitoring the mode of operation. Mechanical indica- tion is not available. Ball Checks can be mounted in both horizontal and vertical applications. The valves access port pro- vides ease of maintenance without removal of the valve from the line. Shut-off Valves There are two types of shut-off valves used in wastewater, quarter- turn and multi- turn. Quarter turn valves include plug valves and ball valves. The most common multi-turn valve in wastewater applications is the gate valve. Plug Valves. Plug valves are available in two different designs, lubricated and eccen- tric, non-lubricated (Figure 8-4). Eccentric, non-lubricated are the most common in wastewater applications. Eccentric plug valves are eccentric in that the plug and shaft are mounted eccentrically to the valve seat. As the plug is rotated out of the seat it is pulled away from the seat rather than scraping against it. This provides ease of operation and long life. Plug valves are typ- ically provided with cast iron bodies and nickel or stainless steel seats although some, particularly in small sizes, are pro- vided with cast iron seats. Plug valves are popular in that they are rugged, easy to Mechanical Controls and Components 102 Figure 8-2: Swing check with angled seat. Figure 8-3: Ball check valve. Chapter 8 2/2/06 4:39 PM Page 102 operate and are easy to automate with elec- tric and hydraulic actuators. An additional advantage is that the valves can be used as stop/check, pump control valves by utiliz- ing electric/hydraulic actuation. They are also excellent in throttling applications for controlling the rate of flow. Manual valves are provided standard with disc position indication. Accessories include extension stems for ground level operation and SCADA control for remote operation. Plug valves are maintained by removing the top access cover. The valve does not have to be removed from the line. Ball Valves. Like Plug Valves, Ball Valves (Figure 8-5) are quarter turn valves. They are full ported and provide excellent flow characteristics. They are popular on smaller discharge applications due to their low cost. Most ball valves require that the valve be removed from the line for main- tenance Gate Valves are commonly used in sub- mersible lift stations because they provide both a full flow opening, and it is easy to extend the stem upwards to ground level for simple manual opening and closing. There is a tendency, however, for solids to accumulate on the valve seat. Normal con- struction of gate valves is either bronze or, for larger sizes, cast iron bodies with bronze trim. Gate valves (Figure 8-6) are commonly available in both rising stem and non-ris- ing stem designs. Rising stem types are pre- ferred because they make it easy to see whether the valve is open (the stem rises) or closed (it goes back down). The stem threads up into the bonnet when the valve is open, keeping it out of the flow path and reducing the chance of solids accumulation and clogging. However, non-rising stem types are often specified when there is a Mechanical Controls and Components 103 Figure 8-4: Non-lubricated eccen- tric plug valve. Figure 8-5: Ball valve. Figure 8-6: Gate valve. Chapter 8 2/2/06 4:39 PM Page 103 clearance problem, because the stem remains in the same location whether the valve is open or closed. Electric/hydraulic actuation is available although expensive due to the multi-turn design. Options include extension stems for ground level operation. Air Valves. Air Valves are used to con- trol air in piping systems. Their presence will promote efficient system operation by removing air from the pipeline as well as providing vacuum protection. The type and size of air valves (Figure 8-7) is dependent on system dynamics. Air Valve manufac- turers can assist with proper valve sizing and selection. Water Hammer Water hammer is the result of line surges that occur when liquid flowing in a pipe is abruptly stopped, causing an energy release, which must be, absorbed between the fluid itself and the piping system. Water hammer is a series of shocks sound- ing like hammer blows, which may have sufficient magnitude to rupture the pipe or damage pumps and valves and fittings. When designing a submersible waste- water lift station, it is important to protect the piping system from damage by water hammer. Many factors can contribute to water hammer including both Check valves and Shut-off valves. A poorly designed check valve that closes due to the force of reverse flow will cause water hammer. It is important that system dynamics be con- sidered when selecting check valves. A rep- utable check valve manufacturer can assist you with the proper selection. Shut off Mechanical Controls and Components 104 Photo 8-8: Access door for sub- mersible station. Duplex well access door covers (top to bottom) hinged, fully opened; partly open; and closed. (Courtesy: The Bilco Company). Figure 8-7: Sewage air valve. Chapter 8 2/2/06 4:39 PM Page 104 valves can also contribute to water ham- mer by being closed too fast. Manual valves should always be closed slowly. In applications with long pipe runs or high head, automated valves designed for slow closure are often used. Slow closure of the valve allows the energy to dissipate slow- ly thereby avoiding water hammer. This can be addressed by considering the use of a power-operated valve that will close, or start to close, before pump shutoff. In extreme circumstances, surge valves or surge tanks are used to relieve the energy. Strainers Trash baskets (strainers) are often speci- fied where there is the possibility of objects larger than the pump can handle entering the wet well. Baskets avoid clogging of the pump and permit easy removal of such objects. They may be installed ahead of the station or at the well inlet. Provisions must be made for removing and cleaning the basket without entry into the wet well. Maintenance It is important that all piping and valves be inspected regularly to ensure that unnecessary loads are not imposed on the submersible pump. Additional head loss is created by improper maintenance of the discharge pipe which can increase the wear rate and decrease the efficiency of the pump. It is advisable to check discharge pressure routinely, to ensure that the pump, the piping, and the valves are not partially clogged or built up with greasy material. Disc position indication is a good idea for check valves to assure that they are cycling with the pump. In the absence of indication, check valves should be checked periodically for any buildup inside the valve. Traditional Swing Check valves will also need to have their shaft seals inspected for leakage. Shut-off valves should be cycled on a scheduled basis per the valve manufacturers instructions. Shaft seals should be inspected periodically for leakage. If an obstruction is caused by a buildup on the inside of a valve, it may be possi- ble to back-flush and eliminate it by using high-pressure water. If this fails, entry to remove the buildup can be made through the valve access port or it may be neces- sary to dismantle the pipe at the point of construction. If the gradual buildup of grease and materials is permitted in the piping and valves, serious problems may occur. This buildup may, in many cases, be difficult to dislodge. If it is a continuing problem, there should be a routine procedure to anticipate and remove it before the prob- lem becomes severe. Access Covers Access covers are used in submersible lift stations to cover and provide access to the wet well and, when used, to valve boxes. The simplest access cover, usually installed on a very small station, is a man- hole cover. It is round rather than square or rectangular, to avoid having it fall into the station. It also has no hinges, and must be lifted manually for personnel to gain access to the station. Easier, safer access is provided by fabri- cated covers with hinged doors. When closed, these doors can have locking pro- visions to limit access to authorized per- sonnel only. When hinged doors are opened to the vertical position, they pro- vide full access to the station and to the valve box. (Figure 8-8) The hinged cover can be fabricated of cast iron, steel, or aluminum. It is avail- able with or without a spring assist. The door must be capable of being locked closed and, preferably, should be able to be locked open. In some applications, submersible lift station access covers must be weathertight. This is usually important when metered sewage, not mixed with stormwater, is processed through the station. The weath- ertight access cover is designed with a door leaf or leaves overlapping a gutter or channel type frame. The surface water is then drained through the frame and away Mechanical Controls and Components 105 Chapter 8 2/2/06 4:39 PM Page 105 from the station. This design can also be fitted with a gasket or other membrane to reduce the passage of sewer odors ema- nating from the station. To make the mem- brane effective, the installer must careful- ly set the frame and shim to ensure that the doors close evenly all around the frame and gasketing. If a lift station must be located in an area subject to flooding or in a location where the access cover must be gas-tight the construction of the unit would be the same. That is, it must be suitably designed with a means of compressing a gasket between machined surfaces on the cover and frame all around the perimeter of the frame open- ing. This is done with lever type dogs, or bolt-down devices, on all four sides and on corners if necessary. This type of door is high in cost and available through a limit- ed number of manufacturers. The size of the access cover for the wet well should be coordinated with the station design, the number and size of pumps, and the guide rail removal system by the designer. The main purpose is to allow ade- quate free space for installation and removal of pumps and, if necessary, entry into the wet well. Nominal sizes are usually given as frame opening sizes. Free space may be some- what less due to the door stop, open door latch, reinforcing members, and handle mechanism. An important factor in access cover selection is the amount of reinforcement, or load capacity. The standard access door is designed to carry either 150 or 300 lbs. live load per square foot. While 150 psf is sufficient to carry pedestrian traffic, many codes require 300 psf units; these are avail- able but are not necessary for normal pedestrian traffic. Be sure to check code requirements in your area prior to instal- lation. For heavier loads, both fabricated and cast heavy duty access covers are available. These units are able to handle 16,000-Ib. (H20) wheel loading in alleys, parking lots, and other off-the-road traffic areas. Fabricated units should not be installed in streets, highways, or other areas subject to high-density traffic. In these applications, it is recommended that heavy-duty cast iron or cast aluminum manhole covers be specified. Aluminum is the most widely used cover material, since it offers adequate strength and provides for low maintenance in cor- rosive damp or wet conditions. Aluminum units are available with an anodized finish. Steel access covers may be furnished with hot dip galvanized, coal tar epoxy, or other properly prepared corrosion-resistant fin- ishes. Mechanical Controls and Components 106 Figure 8-9: How one style of guide rail system works. The pump-motor unit is disconnected, lifted from the station, and dropped back into place. Sealing is by means of a quick-disconnect flange. (Courtesy: Hydromatic Pumps). Chapter 8 2/2/06 4:39 PM Page 106 Specifiers also have a choice of single, double, or triple door designs. If the sta- tion is of a reasonable size, a single door may be used to cover the entire opening at lower cost than a double or triple door. Double door units are usually recom- mended for duplex and larger pump sta- tions. Fabricated access cover doors are nor- mally constructed of 3/16 or 1/4-in. dia- mond pattern plate or other non-skid sur- face of aluminum or steel. Stiffening members are welded to the underside for proper reinforcing. Frames are normally constructed of 1/4- in. aluminum or steel. One common con- struction is a 3-in. x 3-in. or 3-in. x 2-in. angle or aluminum extrusion. For a weath- ertight installation, the common construc- tion is a channel-shaped frame. Hinges are either cast aluminum or steel, normally cadmium or zinc-plated. They may also be forged or formed stainless steel, or forged or formed brass. The hinges should be fastened to the cover with tam- per-proof lock nuts and bolts. All other hardware items are also available in stain- less steel. There can be a provision on the access cover frame for bolting the upper guide rail brackets, either in a fixed or adjustable position, depending upon the guide rail design. Provision can also be made for mounting cable holders and chain hooks. Guide Rail Systems An essential component of a submersible wet well system is a method of connecting and disconnecting the pump from dis- charge piping within the wet well. Guide rail systems permit installation and removal of the pump unit from the top of the wet well. This ends the dirty, time consuming and potentially dangerous task of sending service personnel into the sta- tion. Figure 8-9 illustrates how one sys- tem works. The wet well floor is generally designed to accommodate submersible pumps in such a way that solids will not settle out in "dead" spots and become septic, creat- ing a potential odor problem. Therefore, the pump should be guided to a specific position in the sump where it will engage with the discharge piping. The guide rail or rails are usually made of pipe or sometimes angle, channel, or cable to accommodate the pump manu- facturer's guide brackets that are attached to the pump. The rails should be of rigid material with suitable metallurgy to with- stand the action of liquids and vapors for a reasonable life expectancy of the pump station. Depending on the depth of the wet well, one or more intermediate guide rail supports may be required to maintain suf- ficient rigidity for smooth guidance of the pump unit. The location of the upper guide rail brackets is important. While most sub- mersible pumps are designed with the rail guides on the front of the pump casing, others have one rail on either side. With the latter, provision must be made across the access opening to connect the upper guide rail bracket between the pumps in a duplex or multiple pump station. The access door manufacturer can furnish inte- gral provisions on the door frame to accom- modate these brackets or they can be field-installed by the contractor as part of the well cover structure. The lifting or lowering of the pump unit should be done with either a chain or cable securely attached to the pump. It should be compatible with the hoist or lifting device used, and should have a minimum four-to-one safety factor over the weight of the pump and guide brackets. The actual seal between stationary and movable components may be accomplished in varying ways, depending on the indi- vidual pump manufacturer. In all cases, the manufacturer should be able to assure the owner of a good connection that is free from excessive leakage. All threaded and flanged connections between guide rail components and other piping must be in accordance with American National Standards Institute (ANSI) standards. Mechanical Controls and Components 107 Chapter 8 2/2/06 4:39 PM Page 107 108 Chapter 8 2/2/06 4:39 PM Page 108 Careful preparation and planning is needed to ensure proper installation of all equipment in submersible sewage pump- ing stations. There must be effective coor- dination between the supervising engineer, the mechanical and electrical contractors, and all suppliers. The first step is to make certain that the required station equipment is ordered com- pletely and accurately according to speci- fications, and that considering lead times all of it will arrive prior to the sched- uled installation. This includes not only the pump and electrical control panel, but the station itself (if prefabricated) and all acces- sories, such as piping, valves, and access covers. Receipt and Inspection All equipment should be examined upon receipt for any signs of apparent damage. If damage is indicated, a claim should be filed immediately with the carrier and the supplier should be notified. All parts shipped loose or separately should be checked for loss or damage. If the equipment wont be installed immediately, it is best to store it in a clean, dry location where it will be protected from possible damage. When storing equip- ment, follow the manufacturer's recom- mendations and protect equipment from low temperatures or freezing. Check the equipment prior to storage to anticipate any possible problems at the time of instal- lation. By checking sizes, design features called for on the plans and specifications, and all interface components, installation problems can be minimized. Handling Pumps A submersible pump should be trans- ported and stored in accordance with the pump manufacturer's recommendations. Make sure that it cannot roll or fall over. Always lift the pump by its carrying han- dle, never by the motor cable. In the absence of specific manufacturer recommendations about storage, pumps must be protected against excessive mois- ture and heat. This precaution is necessary to prevent the possibility of moisture dam- age to internal components and the power cord, etc. The impeller should be rotated by hand occasionally (for example, every other month) to assure free movement of 109 Chapter 9 Installation and Start-Up The proper installation of a submersible wet well pumping station involves careful coordination from planning through completion. Deliveries must be scheduled and checked. All accessories must be installed in accordance with the job specifications and the manufacturers instructions. Electrical control panels must be installed and tested with care. When start-up is accomplished properly, the specifier, operator, and owner can be assured of trouble-free operation. NOTE: The information presented in this chapter is a general guide. Builders, design/construction engineers, and operators should consult with and follow applic- able manufacturers' instructions. Chapter 9 2/2/06 4:40 PM Page 109 the rotating elements. Make sure that the cable entry seal conforms to the outside diameter of the cable to prevent leakage into the pump. The end of the power cable must not be submerged, as water may wick through the cable into the motor. After any period of storage, the pump should be inspected, tested and/or recon- ditioned in accordance with the manufac- turer's recommendations before it is put into operation. Pump Station Installation When beginning the installation, make certain that all equipment is on site and that all manufacturer instructional litera- ture is available, has been reviewed, and is followed. In addition to the pump(s), the following items are typically required: Discharge elbow/support base and/or sealing arrangement for connecting the pump to the discharge line. Guide rail(s) consisting of specified material and size. Upper guide rail brackets for attach- ing the rail(s) to the access cover frame or top of the station. Intermediate guide rail supports as required. Specified discharge piping and fit- tings. The proper check valves and shut-off valves. Level sensor or other control equip- ment. Cable holder for level sensors or other sensor brackets. Junction box or conduit box (if required). Access frame (with covers). Control panel. Access Cover Installation There are two common installation methods for access covers. One is to cast the unit into the poured concrete slab well cover. The other method is to frame flange the unit and drop it into the steel well cover. Both types of installation must align properly with the base plate. Prior to cast- ing the door unit into concrete, the cover should be closed and checked to make cer- tain that it rests on the frame all around. Shim the frame as necessary to ensure proper door closure. Remember that alu- minum frames must be protected from the wet concrete by a bituminous coating. Installation procedures when casting the access cover in concrete are as follows: Spring-loaded units Caution: The cover is spring loaded. Do not remove the safety shipping bolt until the unit is ready to be installed in a normal horizontal oper- ating position. Non-spring loaded units shipping bolt or banding should not be removed until the unit is ready to be installed and is in normal horizontal operating position. On angle frame type doors, be sure the concrete anchors are in the proper position when setting the frame. Then remove the banding or safety shipping bolt and plate and the outside latch release handle. Place the access frame and cover on the opening so that the lift handle is in the desired location and the slide rail connec- tions, junction box or conduit box provi- sions, and chain hooks (if all are furnished) are in the proper relationship to the pump base plate and the discharge piping con- nections. Before pouring concrete or anchoring in place, open and close the door(s) and check to see that the door rests on the frame all around. If not, shim under the frame as needed at the corners and recheck for proper door closure. With door(s) closed, place the access frame in position and install the anchor bolt. Pour the concrete flush with the top of the frame. Use care to prevent the con- crete from getting into the frame or around the hinges. Be sure to support the frame to Installation and Start-Up 110 Chapter 9 2/2/06 4:40 PM Page 110 prevent sagging. Do not permit the weight of the concrete to push frame inward and reduce the clearance between door(s) and frame. There is little or no maintenance required on access covers. Painted doors should be cleaned and repainted when nec- essary. Spare parts such as springs, hinges, latches, and arms seldom require replacing. However, should there be a need to replace any of these items, they are usu- ally readily available from suppliers. To ensure that replacement parts are ordered correctly, the broken part should be returned to be matched. If this is not pos- sible, the model number, size, type of metal, year of purchase, and shop order number should be provided. Internal Assembly Now that the access cover is in the prop- er position, you can begin to install the internal station components. Place the pump discharge connection in position. Temporarily secure the guide rail(s) in the upper mounting brackets and the discharge bosses at the bottom. Install the intermediate support brackets, if required. Make sure the rails are in a true vertical position, so the pump will clear the access opening and will slide freely down the rails into place in the discharge con- nection. Once the rails are in proper alignment, bolt the discharge connection into the floor of the station. Connect the discharge pipe to the discharge connection and proceed to install the check valve, shutoff valve, and fittings according to the plans and specifi- cations. All level-sensing devices must be prop- erly secured to the access cover frame or the wet well. Install them at the levels indi- cated on the plans and specifications. Control components, other than level-sens- ing devices, should not be installed in the wet well. Lifting equipment is normally required for handling pumps. It should be able to hoist a pump straight up and down in the station, preferably without having to reset the lifting hook. Make certain the lifting equipment is securely anchored. Keep all personnel out from under suspended loads. Before lowering a pump into place, it must be checked for correct rotation, using one of the following methods: 1. Prior to installation in the wet well, lay the pump on its side and momentarily run (jog) and check it for rotation. When running the pump outside the wet well, care must be taken to stay clear of the impeller and to provide a safe, temporary connection of the motor leads. The best procedure is to lift the pump with a hoist or tilt it slightly and observe the rotation. An arrow on the pump casting, or instruc- tions in the Pump Instruction and Operation Manual (IOM), will show the proper direc- tion of rotation. This is the most accurate method to ensure proper rotation; however, other methods are usually provided as a sec- ondary check or for circumstances when the pump cannot be lifted from the station. 2. After installation, if the check valve has an external operating arm, observation will indicate which rotation of the motor opens the check valve widest. This indi- cates the higher flows, and is the correct rotation for the pump. 3. If pressure taps are available, rotation can be ascertained by reading the shut-off head on a pressure gauge. The proper rota- tion will produce the higher pressure. 4. The least desirable procedure is to position the pump in the Hand mode, using the Hand-Off-Automatic (HOA) switch, lower it to the bottom of the wet well, and check the drop in water level in the well. The rotation resulting in the faster draw- down is the proper rotation. One of the above procedures must be used to check and ensure proper rotation of each pump before start-up of the station. Keep in mind that visual inspection of the rotating elements is the most accurate method. The direction of rotation on three phase pumps may be changed by interchanging Installation and Start-Up 111 Chapter 9 2/2/06 4:40 PM Page 111 any two motor leads at their control panel connections. For single phase pumps, if improper rotation is observed, consult the IOM or contact the pump manufacturer. After the proper rotation is verified, lower the pump along the guide rail(s). Upon reaching its bottom position, it should automatically connect to the dis- charge. Adjust as required, following the manufacturer's recommendations. Fasten the lifting chain on the access frame eyebolt and fasten the cables on the cable holder. Cable supports are required for deep installations. Run the pump and level control cables up to the electric con- trol panel or into the junction box, if used. The pump and level control cables should be long enough to reach the control panel without splicing. If a junction box, conduit box, or quick connector plugs are utilized, they should be located outside the wet well or, if located in the wet well, be of at least NEMA Type 4 construction. It is highly recommended that conduit seal offs be located between the wet well and the control panel to prevent gas migra- tion into the control panel enclosure Arrange for a cable, if needed, between the sump and the electrical control panel. Make sure the cables are not sharply bent or pinched, and that all connections are sealed and watertight to prevent leakage from ground water. Control Panels Before making a new installation, a qual- ified electrician or factory service techni- cian should verify the horsepower, voltage rating, and full load amperage of each pump. This information should be used to ensure that the control panel is of the cor- rect horsepower, and that the heater coils furnished in each motor starter overload unit are sized or set correctly to match the motor's operating current as given on the motor nameplate. The service voltage and frequency should be checked to ensure they are the same as the motor rating. This information should be used to cross-check the circuit breakers, fuse, or disconnect ratings. All electrical work must comply with national and local codes and regulations. At the time of installation, the panel or equipment should be checked for missing or loose components including a correct wiring diagram. All wire terminations should be checked for tightness. Care must be taken in handling the control panel and equipment during installation to avoid damage to the enclosure or any of its com- ponents. Location and provisions for mounting the panel should be shown on the plans for the job. Make certain the enclosure is of the type specified for that particular location. Adequate racks, mounting brack- ets, and fastening hardware must be used to securely mount the panels and devices. On flat surfaces, panels should have a slight clearance between the back of the panel and the mounting surface to allow for air circulation. While clearance is usu- ally provided by the enclosure design, it may need to be furnished by mounting hardware. This assures heat dissipation and prevents moisture accumulation. If the panel is mounted on a rack, it must be constructed and braced to provide a flat, rigid surface that will not distort the panel and cause possible door alignment prob- lems. Mounting bolts and hardware must be of sufficient size to provide stable positioning and of materials suitable for the operating environment. Field Wiring All conduits and wires must be installed as required on the plans for the specific job. All cable entrances into the enclosure must be in accordance with the NEC, and shall maintain the integrity of the NEMA enclosure, to prevent intrusion of moisture, dust, and gas vapors. When possible, con- duits should be attached from the bottom of the enclosure to facilitate weatherproof- ing. Weatherproof hubs and sealed fittings should be used. The size of conduits and wires must be Installation and Start-Up 112 Chapter 9 2/2/06 4:40 PM Page 112 adequate for the specific requirements of the incoming service, pump motor leads, and remote control devices. The NEC must be used as a minimum guideline. After the installation of the conduit and wiring, make certain that all terminations in the control panel conform to the panel manufacturer's diagrams and instructions. The incoming service voltage must be cor- rect for the panel. Typically, three phase systems are designed for a 208, 240, 480, or 575 volt, four wire service voltage. Single phase systems are most often 208 or 240 volt, two or three wire, but are some- times 120 volt, two wire service voltage. As a safety precaution, prior to connect- ing the motor leads to the control panel or applying power to the pump, megohm readings should be taken and recorded with a 500-volt megger. Connect all motor leads together and check the combination to ground. The readings should be above 20 megohms at all points. A motor should not be run if any reading is below 10 megohms. If this is the case, the source of the low readings should be found and cor- rected. If the readings are between 10 and 20 megohms, the pump should be run for short periods and the readings rechecked. Only after tests are complete should the motor leads be connected permanently to the control panel. The pump leads must now be connect- ed to the control panel following the panel diagram, using the pump manufacturer's wiring diagram to distinguish and verify the connection and color coding of the leads. Internal pump/motor safety controls should be identified following the pump manufacturer's wiring diagram and con- nected to the panel as specified by the panel manufacturer. Make certain the pump is correctly grounded. If automatic control of the pumps is pro- vided by liquid level sensors in the wet well, all connections must be made to the proper terminal points in the control panel. Care must be taken to identify each sensor and its specific function. Proper connec- tions ensure sequential and automatic oper- ation of the pumps. Wires must be marked to provide future identification should re-connection be required during maintenance or trou- bleshooting. A record should be made in the permanent file for the control panel regarding field wire connections, wire sizes and types, cable lengths, and any other related information. This file can be valu- able during normal maintenance, for emer- gency situations, and as a reference for future installations. When incoming service voltage is avail- able and the system is complete and ready to be put into service, a qualified electri- cian should be present. If the service volt- age is 240 volt, three phase, four wire from Delta-connected transformers, the "high line" must be identified; it has a higher than 120 volt (usually approximately 210 volt) reading phase to neutral. The control panel must then be checked to make cer- tain no control circuits or 120 volt operat- ing devices are connected to this incoming high line. Some local codes require that the high line be on a particular phase connection, usually Phase B or sometimes Phase C. (Consult local codes to determine if there is such a requirement in your area.) Most control panels are designed to use Phase A for all 120 volt phase to neutral circuits when no control transformer is used. Start-Up and Testing Many pump and panel manufacturers have special forms that can be used dur- ing the start-up of the station (See Figure 9-1). Some manufacturers require that these forms be filled out and returned to ensure warranty on the pumps, control panels, and station components. This type of form provides a detailed description of the procedures and tests to be performed. The following summarizes these proce- dures. The panel is ready to be put into service after the incoming service voltage has been checked on the line side of the main cir- cuit breaker or disconnect, and it is veri- fied that all phases and neutral (if used) are present and at acceptable levels. Installation and Start-Up 113 Chapter 9 2/2/06 4:40 PM Page 113 Figure 9-1 START-UP REPORT FORM This report is designed to insure the customer that customer service and a quality product are the number one priority. Please answer the following questions completely and as accurately as possible. Please mail this form to: (Manufacturer's Name and Address) 1) Pump Owner's Name Address Location of Installation Person in Charge Phone Purchased From 2) Model Serial No. Voltage Phase Hertz Horsepower Rotation: Direction of Impeller Rotation (Use C/W for clockwise, CC/W for counterclock- wise) Method Used to Check Rotation (viewed from bottom) Does Impeller Turn Freely by Hand? Yes No 3) Condition of Equipment Good Fair Poor Condition of Cable Jacket Good Fair Poor Resistance of Cable and Pump Motor (measured at pump control) Red-Black Ohms Red-White Ohms White-Black Ohms Resistance of Ground Circuit Between Control Panel and Outside of Pump Ohms MEG Ohm Check of Insulation: Red to Ground White to Ground Black to Ground 4) Condition of Equipment at Start-Up: Dry Wet Muddy Was Equipment Stored: ___ Yes ___ No. If YES, length of Storage: Describe Station Layout 5) Liquid Being Pumped Debris in Bottom of Station? ___ Yes ___ No Was Debris Removed in Your Presence? ___ Yes ___ No Are Guide Rails exactly Vertical? ___ Yes ___ No Is Base Elbow Installed Level? ___ Yes ___ No 6) Liquid Level Controls: Model Is Control Installed Away from Turbulence? ___ Yes ___ No Operation Check: Tip lowest float (stop float), all pumps should remain off. Tip second float (and stop float), one pump comes on. Tip third float (and stop float), both pumps on (alarm on simplex). Tip fourth float (and stop float), high level alarm on (omit on simplex). If not our level controls, describe type of controls Does liquid level ever drop below volute top? ___ Yes ___No 7) Control Panel Model No. Number of Pumps Operated by Control Panel 114 Chapter 9 2/2/06 4:40 PM Page 114 NOTE: At no time should hole be made in top of control panel, unless proper sealing devices are utilized. Control Panel Manufactured By Others: Company Name Model No. Short Circuit Protection Type Number and Size of Short Circuit Device(s) Amp Rating Overload Type Size Amp Rating Do Protective Devices Comply With Pump Motor Amp Rating? ___ Yes ___ No Are All Connections Tight? ___ Yes ___ No Is the Interior of the Panel Dry? ___ Yes ___ No lf "No," correct moisture problem. 8) Electrical Readings: Single Phase: Voltage Supply at Panel Line Connection, Pump Off, L1, L2 Voltage Supply at Panel Line Connection, Pump On, L1, L2 Amperage: Load Connection, Pump On, L1 L2 Three Phase: Voltage Supply at Panel Line Connection, Pump Off, L1-L2 L2-L3 L3-L1 Voltage Supply at Panel Line Connection, Pump On, L1-L2 L2-L3 L3-L1 Amperage, Load Connection, Pump On, L1 L2 L3 9) Final Check: Is Pump Seated on Discharge Properly? ___ Yes ___ No Was Pump Checked for Leaks? ___ Yes ___No Do Check Valves Operate Properly? ___ Yes ___ No Flow: Does Station Appear to Operate at Proper Rate? ___ Yes ___ No Noise Level: Acceptable Unacceptable Comments: 10) Describe and Equipment Difficulties During Start-Up: 11) Manuals: Has Operator Received Pump Instruction and Parts Manual? ___ Yes ___ No Has Operator Received Electrical Control Panel Diagram? ___ Yes ___ No Has Operator Been Briefed On Warranty? ___ Yes ___ No Name/Address of Local Representative/Distributor 12) I Have Received the Above Information. ___ Yes ___ No Name of Operator Name of Company Date I Certify This Report To Be Accurate. Signed By (Start-Up Person) Employed By: Date Date and Time of Start-Up Present at Start-Up: ( ) Engineers Name ( ) Operators Name ( ) Contractors Name ( ) Others 115 Chapter 9 2/2/06 4:40 PM Page 115 All circuit breakers and selector switch- es must be in the Off position. The main circuit breaker or disconnect can then be turned On. One at a time, each of the other circuit breakers should be turned On, to check the load side of each for correct volt- age. This includes the control circuit. With sufficient water in the well, turn each pump operating selector switch Hand- Off-Automatic (HOA) to the Hand position to run each pump. Amperage readings should be taken and recorded on each motor lead with a clamp-on ammeter. The phase-to-phase voltage must be checked and recorded at this time. If there is exces- sive amperage draw on one leg, start trou- bleshooting by checking the manufactur- er's recommendations. Consult with the power company only after all other checks have been made. The initial readings for amperage, volt- age, and ohmmeter resistance, plus megohm readings, should be the start of a permanent maintenance file. Monthly, quarterly, or annual readings should be taken as part of a good preventive mainte- nance program. They are the basis for scheduled checks, which can indicate the trend of the motor current draw and can help prevent major outages and costly motor rewind jobs. Operational Checks When start-up and testing is completed, the system is ready to be checked for auto- matic operation. Both or all of the pump operating selector switches should be turned to the Auto position, and the alarms turned On or reset as required for normal operation. The best way to check and correctly set the On and Off levels is to provide an exter- nal water supply source to fill the wet well to various predetermined levels. This water can be from a nearby hydrant or other source. Care should be taken when dis- charging water into the wet well not to affect floats or other controls. By control- ling the fill and then observing or setting the operating points, the automatic cycle or cycles of operation can be checked, no mat- ter what type of level controls are employed. To achieve second and/or subsequent pump start levels, the circuit breaker or dis- connect can be turned Off for the lead pump. This allows the wet well to fill, without running the lead pump, to the lag pump On level for checkout. All pumps may be turned Off to allow checking and testing of alarm levels. The pumps should be permitted to pump, to allow checking of the desired Off level. If a low alarm level is included below the nor- mal Off level, a pump may have to be run in the Hand mode to check it. If guaran- teed submergence with redundant low water cutoff is specified, it should be checked to be sure the wiring has elimi- nated the possibility of Hand operation.The control system should be cycled more than once to check the proper and automatic alternation sequence of the pumps. If the panel is supplied with a manual alternator switch, it should be operated and the pumps cycled again to check for sequenc- ing. Each run cycle, after alternation, should be checked to run both lead, lag and any subsequent pumps to ensure complete, correct alternation of the duty cycle. Simulation Testing The following steps should be taken only in those extreme cases where sufficient water is not available and the pump(s) cannot be run in the well. Because the pump(s) are not run and the actual well water level is not used to energize the level sensing devices, this proce- dure is not recommended. If automatic controls are used with level sensor switches, they can be removed from the wet well and the controls manually actuated. Care must be taken to mark each sensor. With all controls in the Off posi- tion, a low wet well level is simulated. By actuating the controls (either manually or by lowering them into a large container of water) one at a time, a rising wet well level is simulated. It is very important that the correct sequence is achieved when simulating a Installation and Start-Up 116 Chapter 9 2/2/06 4:40 PM Page 116 rising level and also as the floats are turned back to a vertical position or raised out of the container of water. When simulating automatic operation, enough water must be maintained in the wet well to allow the pump(s) to run full cycles without damage; otherwise, they should be turned Off at their circuit breaker or disconnect switch. When the pumps are turned Off, the starters for each pump and their run indi- cator pilot lights can be observed. If each pump control circuit is isolated by turning Off its circuit breaker or disconnect, the pump leads may have to be disconnected, and the circuit breaker or disconnect left On to observe starter operation while testing. Purged air bubbler control systems can be checked through simulation by someone who fully understands their operation. The bubbler line to the wet well must be dis- connected and a needle type cut-off valve installed on the line from the controls. Some units may have factory-installed shut- off and bleed valves. With the test valve completely open, the level gauge should read zero to simulate a low wet well level. As the test valve is slow- ly closed, creating a back pressure on the controls, the gauge will indicate the simu- lated level and the pumps should start as the required levels are reached. When the test valve is slowly opened, lowering the back pressure on the controls, the pumps should turn Off. This procedure may be repeated as required to adjust operating levels and check alternation with each duty cycle. During testing, the actual wet well level should be checked to ensure the pumps do not pump so far down as to damage them. Other Checks During the check-out of control systems, the pump run pilot light indicators, elapsed time meters, and any other associated con- trols should be reviewed for proper opera- tion. The alarm levels, when activated, should operate all devices in the system. These may include an alarm light, pilot light, audible horn or bell, and a relay to provide remote signal contacts or teleme- tering contacts. All the alarm devices should be checked for proper operation, including audible alarm silencing circuits or switches, and any reset pushbutton, if used. If any special control or alarm features are included in the system, they should be checked by simulation if actual conditions cannot be achieved. These may include seal failure indicators, motor thermal sen- sors, or telemetered incoming or outgoing signals. Another device often used and not always checked is the phase monitor. Most have three functions loss or low voltage on a single phase, loss or low voltage on all three phases, and phase rotation reversal. By turning off the service voltage to the panel, disconnecting one of the sensing leads to the phase monitor, and then insu- lating it when the power is turned back on to the panel, the pumps should not oper- ate in either the Hand or Automatic mode. Reversing the above procedure, the lead should then be reconnected. This will check the loss of a single phase feature. On some units, if the service nominal voltage is low enough, the set point on the monitor can be raised sufficiently above nominal voltage to cause the running pump or pumps to drop out. This will check the three phase low voltage setting of the phase monitor. By turning off the service voltage and reversing two of the sensing leads on the phase monitor (to induce improper rota- tion), and then restoring the service volt- age, the pumps should not operate in either the Hand or Automatic mode. Reversing the above procedure, the leads should then be reconnected. This will check the phase reversal feature of the phase monitor. These checks are important, since they offer the protection needed during normal operation of the system. The last is impor- tant if the service is ever disconnected and reconnected, to prevent the pumps from being run in reverse rotation. If a station is provided with a power plug for the use Installation and Start-Up 117 Chapter 9 2/2/06 4:40 PM Page 117 of a portable standby generator, this reverse phase feature is essential to ensure that the generator phase rotation is matched with the normal service phase rotation. Final Tests After the above tests have been com- pleted, the panel should be thoroughly checked to ensure that all wires have been reconnected properly, all switches or jumpers used for simulations have been removed, and all circuits restored to nor- mal operation. With the service voltage turned Off, all wire terminations should be rechecked for tightness and the panel cleaned to ensure a good, maintainable environment. The panel should now be ready for continuous automatic operation. The run time on elapsed time meters should be read and recorded for each pump. These readings should be the start of a permanent maintenance file. Periodic readings should be taken and recorded as part of a good preventive maintenance pro- gram. With these readings, the alternating duty cycles can be checked to ensure operation of the alternator. Many pump and motor maintenance schedules are based on hours of operation. Actual automatic cycles are monitored to be sure they are not exces- sive. For submersible motors, a maximum of 10 to 15 starts per hour are acceptable in terms of equipment life. Over a period of time, this record may show system demand trends and indicate the need for larger pumps. By calculating the pumping rate of each pump and the hours of run time, the gallons of water pumped for a given time period can be esti- mated. This may indicate problems with increased water infiltration into the system due to cracked or broken lines, based on an increase in gallons pumped with no other substantial changes within the sys- tem. Make periodic checks during the first few days of operation of a new system. This can uncover unforeseen problems and help the operator become familiar with duty cycles and other characteristics of the pumping station. This special attention can help avoid future problems. Installation and Start-Up 118 Chapter 9 2/2/06 4:40 PM Page 118 Safety Precautions CAUTION: Note and read all safety precau- tions before performing any operation or main- tenance procedure. To minimize the risk of accidents in connection with service work, the following rules as well as all applica- ble laws, regulations and manufacturers' rec- ommendations must be followed: Be aware of health hazards. Observe strict cleanliness. Be aware of the risk of electrical acci- dents. Check the explosion risk before weld- ing or using electric hand tools in or near the station. Never weld or use electrical tools in the wet well after it has been in operation. Make sure that all lifting equipment, when used, is in good condition and of ade- quate capacity. Provide a suitable barrier around the work area for example, a guard rail. Make sure that all personnel have a clear path of retreat. Use safety helmets, safety goggles, and protective shoes or boots. All personnel working with sewage sys- tems must be vaccinated against any dis- eases that can occur. Since sewage pumps are designed for use in liquids which can be hazardous to the health, make sure that all equipment has been thoroughly cleaned. To prevent injury to the eyes and skin, observe the following rules: 1. Always wear goggles and rubber gloves. 2. Wash and rinse the pump thoroughly with clean water before starting work. 3. Wash and rinse any components in clean water after disassembly and then dry thoroughly. If you get hazardous chemicals in your eyes, contact a doctor immediately. If you get hazardous chemicals on your skin, remove contaminated clothes, wash your skin with soap and water, and seek medical attention immediately. Recommended Inspections CAUTION: Before starting work on any pump, make sure it is isolated from the power supply and cannot be energized. This applies to the control circuit as well. One method is to tag and lock the con- trol panel to let other personnel know that you are working on the station. Keep in mind that some systems have an override 119 Chapter 10 Operation and Maintenance Regular inspection and preventive maintenance ensure continued, reliable opera- tion of the entire submersible pumping system. All stations, pumps, and operating equipment should be inspected at least once a year, and more frequently under severe operating conditions. One of the major advantages of a submersible station is the ability of the service technician to handle most maintenance and service onsite, without entering the wet well. All equipment in the station should be backed by manufacturers service manuals. This material should be carefully read, filed, and consulted whenever servicing is required. Chapter 10 2/2/06 4:41 PM Page 119 switch at the treatment plant or other buildings. Make sure that this switch is also Off and tagged at the other building before you start working on the station. After the pump(s) have been isolated from the power supply and pulled to the top of the station, the appropriate manu- facturer's service manuals should be con- sulted and the following inspection guide- lines should be followed. Visible Parts On Pump And In Station 1. Check for vandalism or other station damage. 2. Make certain the access cover works properly. Check the hold-open device to ensure that it is engaged. 3. Make certain that the guide rails are completely vertical. 4. Check the condition of the lifting eye, chains, hooks, and wire ropes. 5. Make certain that all screws, bolts, and nuts are tight. 6. Replace or repair worn or damaged parts. Pump Casing and Impeller 1. If the clearance between the impeller skirt and the pump casing or wear ring exceeds the manufacturer's recommenda- tions, it may be necessary to adjust the impeller or replace the wear rings. 2. Wear on the outlet flange from the pump casing usually causes corresponding wear on the discharge connection. 3. Follow the manufacturer's instructions for disassembly, inspection, and reassem- bly of the impeller and volute. When it is disassembled, check the motor shaft, impeller, and volute bore for wear or dam- age. 4. Follow the manufacturer's instructions for disassembly, inspection, and reassem- bly of the shaft seal. It must be clean and properly seated before reassembly. 5. Always replace worn or damaged parts. Electrical Insulation Perform a megger (insulation resistance) test between the pump motor leads and pump casing. A low 20 megohms or less reading indicates moisture entry into the motor chamber or power cord, or other deterioration of the insulation system. Such problems should be corrected before a major breakdown occurs. Oil Quantity and Condition A. Oil-Filled Motors 1. Caution: If there has been any leak- age, the motor housing may be under pressure. Hold a rag over the inspec- tion plug to prevent splatter when loosening the plug. 2. Check the oil in both the motor hous- ing and the seal cavity through the oil inspection plugs. The oil level may be low or emulsified (cream-like), which indicates that water has entered the cavity and a leak is present. One pos- sible cause is an inspection plug which is not sufficiently tight. Check the sealing surface of the motor hous- ing, the cable entry, and the condition of the shaft seal. Whatever the prob- lem, correct it and make certain that the oil is refilled to the proper level with the motor manufacturers rec- ommended oil. B. Non Oil-Filled Motors If there is any liquid in the motor housing, a leak is present and all seal- ing faces should be checked as listed above under Oil-Filled Motors. Cable Entry 1. Make certain that the cable connec- tion is tight. 2. If the cable entry leaks, it may be nec- essary to replace the cable seal. See the manufacturer's manual for instructions. 3. When refitting a cable which has been used before, even when the jacket has not been damaged, always cut off a short piece of the cable so that the cable entry seal Operation and Maintenance 120 Chapter 10 2/2/06 4:41 PM Page 120 does not close around it at the same point. 4. If the outer jacket of the cable is dam- aged, replace the cable. Make sure the cable has no sharp bends and is not pinched. Controls 1. Check liquid level sensors throughout their entire range of operation. Clean, adjust, replace, and repair damaged equip- ment. Follow the manufacturer's instruc- tions. 2. The same procedure should be used for checking the balance of the control sys- tem. In particular, check signals and the tripping function, and make sure that the relays, lamps, fuses, and connections are intact. Replace all inoperative equipment. Piping and Valves Repair all flaws and replace inoperative equipment. Fault Tracing A voltmeter, ohmmeter, and ammeter together with the job wiring diagram are required to test, measure, and carry out fault tracing on electrical equipment. Fault tracing must always be performed with the power supply disconnected and locked Off, except for those checks which can be performed only with power. Electrical work must be performed by qualified electricians and all applicable local, state, and national safety regulations be followed. Observe the recommended safety precautions previously mentioned in this chapter. Major Servicing Submersible sewage pumps can be ser- viced in the field at qualified facilities. If the pump is still in warranty, it should be serviced by an authorized shop. Manufacturer's service manuals provide detailed instructions for replacement of impellers, stators, seals, and bearings. To facilitate field maintenance and ser- vice, many manufacturers provide a list of authorized service facilities, recommended spare parts, and the maintenance equip- ment required. If the motor carries an approval label such as Underwriters Laboratories (UL) or Factory Mutual (FM), in order to retain this approval label, major motor repair must by performed by an authorized UL or FM repair facility. Operation and Maintenance 121 Trouble Checklist Below is a list of common problems and their probable causes. These are gen- eral guidelines only. Consult the specific manufacturer's manual for detailed instructions. Pump Operations Problem Possible Cause Remedy 1. Pump will not start. No power to motor. Check for blown fuse or open circuit breaker. Selector switch may be Turn to On position. in the Off position. Chapter 10 2/2/06 4:41 PM Page 121 Problem Possible Cause Remedy Control circuit breaker Reset the circuit breaker. may be tripped. Overload heater in starter Push to reset. may be tripped. Overload heater in starter Replace the heater. may be burnt out. 2. Pump will not start and May be improperly Turn power Off and overload heaters trip. grounded. check motor leads with megger or ohmmeter. Motor windings may be Check resistance of motor imbalanced. windings. If three phase, all phases should show the same reading. Impeller may be clogged, If no grounds exist and blocked or damaged. the motor windings check out satisfactorily, remove the pump from the well and check for impeller blockage. 3. Pump runs but will not Pump may be air-locked. Turn pump Off for several shut off. minutes, then restart. Lower level switch may be Check to be certain the locked in closed position. level control is free. Selector switch may be in Switch to Auto position. the Hand position. 4. Pump does not deliver Discharge gate valve may Open and unclog valve. proper capacity. be partially clogged. Check valve may be Valve must be cleared. If partially clogged. there is an outside lever, move it up and down. Discharge line may be Use a sewer cleaner or clogged. high-pressure hose to clear the obstruction. Pump may be running in Low speed pumps can the wrong direction. operate in reverse direction with little noise or vibration. See Chapter 8 for methods of estab- lishing and correcting rotation. Operation and Maintenance 122 Chapter 10 2/2/06 4:41 PM Page 122 Problem Possible Cause Remedy Discharge head may Check total head with too high. gauge when pump is operating. Compare against original design and previous operating records. If pump has been in service for some time and capacity falls off, remove the pump and check for wear or a clogged impeller. 5. Motor stops and then Heat sensors in the motor Impeller may be partially restarts after short period may trip due to excessive clogged resulting in the but overload heaters in heat. sustained overload, though starter do not trip. not high enough to trip the overload heater switch. Motor may be operating Check locations and out of liquid due to a operations of level controls. failed level control. Pump may be operating The wet well may be too on a short cycle. small or water may be repeatedly returning to the well due to a leaking check valve. Both must be checked. Control Panels Problem Possible Cause Remedy 1. Pumps 1 and 2 will not Service voltage not On to Turn On and check for run in Hand or Auto panel. proper voltage. positions. Run lights not On. Main or control circuit Turn On or reset and turn breakers tripped or turned On all circut breakers. Off. Main or control Check and replace any circuit fuses blown. blown fuse. Motor heat sensor Check motor heat sensor connections not made connections and correct. properly. 2. Pumps 1 and 2 will not Motors not wired Check and correct run in Hand position. Run properly. connections and cables lights are On. to panel. Incorrect voltage starter Check and correct starter coils. coils voltage rating to match control circuit voltage. Operation and Maintenance 123 Chapter 10 2/2/06 4:41 PM Page 123 Problem Possible Cause Remedy 3. Pump 1 or 2 will not run Pump circuit breaker Turn On or reset and turn in Hand position. Run tripped or turned Off. On breaker. light not On. One pump operates in Hand position. Pump circuit fuse blown. Check and replace any blown fuses. Motor starter overload Reset overload after tripped. checking motor. Motor heat sensor circuit Check continuity of motor open or not properly heat sensor. Correct connected. connections. 4. Pumps 1 and 2 will not Level in wet well not high Fill or allow wet well to run in Auto position. enough to turn on pumps. fill to required levels. Level float switches may Check and connect each be incorrectly connected float correctly or replace or failed. if required. Air bubbler supply may Check and ensure air be off or failed. supply is On, bubbler line is working in wet well and has no leaks. Pressure switches or Check and adjust pressure sensors may not be switches to correct levels adjusted or sequenced and sequence. properly. Relay or other control Check and replace any device failed. control relay, alternator or other device with defective coil or contacts. 5. Alarm light and/or audible No probable panel None. alarm turns On with both problem. pumps running. Possible system problem Check and clear check - i.e., discharge line valve or line of clogged. obstruction. Temporary high level Monitor station operation condition after power until High Level is failure or influent surge. reduced. 6. Alarm light and/or audible Test Hand operation of See Remedy for #3. alarm turns On, with one pump not running and or both pumps not refer to Problem #3. running. Operation and Maintenance 124 Chapter 10 2/2/06 4:41 PM Page 124 Problem Possible Cause Remedy Refer to Problem #4-B, D or E. See Remedy for #4-B, 4-D or 4-E. 7. Circuit breaker tripped for Motor not wired properly. Check and correct motor power. connection to panel. Short in pump cable, Disconnect motor and wiring or motor. check wiring. Check motor for shorts or grounds. Size of breaker too small Check and correct breaker and/or ambient heat size for motor and/or problem. provide ventilation or compensation for ambient heat. 8. Blown fuse for motor Same as Problem #7-A, B See Remedy #7. power. or C. 9. Pumps do not alternate. Defective alternator relay. Check and replace alternator. Improper sequencing of Check and correct float switches or pressure sequence of controls to sensors. insure Off, lead, lag sequence. 10. Indicator pilot light not Pilot light bulb failed. Replace lamp with correct On at the time of a voltage replacement. function or alarm condition. Operation and Maintenance 125 Chapter 10 2/2/06 4:41 PM Page 125 126 Chapter 10 2/2/06 4:41 PM Page 126 ACCESS COVER A removable device to provide access to a wet well and/or valve box. May include frame, doors, locks, and other accessories. BEST EFFICIENCY POINT (BEP) The combination of head and flow at which a given pump operates most efficiently. BRAKE HORSEPOWER (BHP) The power delivered to the pump shaft under stat- ed operating conditions of the pump where horsepower is 550 foot/pounds per second, expressed by graph or figured by: BHP = Q x H x S.G. where: K x Eff. Q = U.S. GPM H = Head in Feet S.G. = 1.0 (for water) K = 3960 Eff. = Pump Hydraulic Efficiency CAPACITY The quantity of liquid that can be contained, or the rate of liquid flow that can be carried. CLEAR WATER Treated, filtered water; the discharge from a water treatment plant. CLOSE-COUPLED A pump directly connected to its power unit without any reduction gearing or shafting. CYCLE TIME The total time period from when the pump turns On to when it turns Off. DISCHARGE The flow or rate of flow from a pump or pumping system. DISCHARGE DIAMETER (See Pump Discharge Size). DISCHARGE PIPE The pipe that exits the wet well or valve box. DRY WELL A dry compartment in a pumping station, near or below pumping level, where the pumps are located. DUPLEX A pumping station containing two pumps. DYNAMIC HEAD The head (or pressure) against which a pump works. EDDIES Circular movements occurring in flowing water, caused by currents set up in the water by obstructions. EFFLUENT Wastewater or other liquid, partially or completely treated, flowing out of a septic tank or treatment unit. FLOOD-PRONE An area subject to frequent flooding. FORCE MAIN A pressure pipe joining the pump discharge at a water or waste- water pumping station with a point of gravity flow. FREE BOARD The vertical distance between the normal maximum level of liquid in a tank and the top of the tank. 127 Glossary Of System Terms Glossaries 2/3/06 10:19 AM Page 127 FRICTION LOSS The head loss of liquid flowing in a piping system as the result of the disturbances set up by the contact between the moving liquid and the system components. It is a function of pipe diameter, length, surface roughness, and flow rate. GALLONS PER MINUTE (GPM) The volume delivered at the pump discharge flange expressed in gallons per minute (GPM). Expressed on the X axis of a pump curve. GRINDER PUMPS Specialized submersible pumps which mechanically disintegrate sewage. GROUNDWATER Subsurface water occupying the saturation zone. In a strict sense, the term applies only to water below the water table. GUIDE RAIL SYSTEM A device which allows the pump-motor unit to be installed in or removed from the wet well, without disconnecting any piping and without requiring personnel to enter the wet well. H 20 WHEEL LOADING Refers to the type of construction used in the fabrication of access doors or covers for wet wells or valve boxes that must withstand vehicular traffic. Rating is 16,000 lbs. per sq. ft. live load. HEAD The height of the free surface of fluid above any point in a hydraulic sys- tem; a measure of the pressure or force exerted by the fluid. HYDRAULIC GRADIENT The slope of the hydraulic grade line, the rate of change of pressure head; the ratio of the loss in the sum of the pressure head and position head to the flow distance. IMPELLER A rotating set of vanes designed to impel rotation of a mass of fluid. IMPELLER DIAMETER The concentric outside diameter as measured radially of the pump impeller. INFILTRATION The quantity of ground or near-surface water that leaks into a pipe or wet well through joints, porous walls, or breaks. INFLOW The extraneous flow which enters a sanitary sewer from sources other than infiltration. INTAKE The flow or rate of flow into a pump or pump station. LIFT STATION A system that includes pumps, tanks, appurtenant piping, valves, and other mechanical and electrical equipment for pumping water or wastewater. Also see pumping station. LIQUID LEVEL CONTROLS In-station devices which start or stop the pump(s) in response to the liquid level within the well. Connected to a control panel. LAG PUMP A succeeding or backup pump in a pump system. Control systems usually alternate pump operation. LEAD PUMP The first pump to start in a pump cycle. NET POSITIVE SUCTION HEAD (NPSH) The net positive suction head is the total suction head in feet of liquid absolute determined at the suction nozzle and the referred datum less the vapor pressure of the liquid in feet absolute. NET POSITIVE SUCTION HEAD AVAILABLE (NPSHA) The absolute pressure of the liquid at the inlet of the pump. NET POSITIVE SUCTION HEAD REQUIRED (NPSHR) Based on the need of a specific pump. Remains unchanged for a given head, flow, rotational speed, and impeller diameter; changes with wear, liquids, and temperature. Glossary of System Terms 128 Glossaries 2/2/06 4:49 PM Page 128 NON-CLOG A pump designed to pass solids of a specific size. For example, a sub- mersible pump with a 4-in. discharge may be capable of passing 3-in. spherical solids. PEAK FACTOR A variable multiplier used with average flow to determine required pump capacity for wastewater lift stations or potable water booster stations. Variation is determined by the size and type of facility. PEAK FLOW Maximum flow. PUMP CASING See Volute. PUMP DISCHARGE SIZE The inside diameter of the discharge port of the pump as measured at the integrally cast discharge flange to the pump casing (volute). PUMP HYDRAULIC EFFICIENCY Expressed as a percentage of liquid horsepow- er to brake horsepower over the recommended operating range of the indicated impeller size(s). PUMP RELEASE SYSTEM See Guide Rail System. PUMPING STATION Discharges into a pressurized force main (See Lift Station). RAW WATER Untreated water; usually the water entering the first treatment unit of a water treatment plant. RPM Revolutions per minute of the motor/pump rotating assembly. SANITARY WASTEWATER Wastewater discharging from the sanitary conveniences of dwellings, including apartment houses, hotels, office buildings, industrial plants, or institutions. SCUM Floating matter which rises to the surface of a liquid and forms a layer or film. SEALING FLANGE The connection between the pump discharge and force main when used with guide rail systems. SEDIMENTATION The process of subsidence and deposition of suspended matter carried by water, wastewater, or other liquids, by gravity. It is usually accomplished by reducing the velocity of the liquid below the point at which it can transport the sus- pended material. SEPTIC TANK An underground vessel for treating wastewater (most often from a single dwelling or building) by a combination of settling and anaerobic digestion. Effluent is usually disposed of by leaching. Contents (also called septage) is pumped out periodically and hauled to a treatment facility for disposal. SEWAGE Household or commercial wastewater that contains human waste. Distinguished from industrial wastewater. SIMPLEX A pumping station containing one pump. SLUDGE The accumulated solids which separate from liquids, such as water or wastewater, during processing. SIPHON The potential for atmospheric pressure to force a liquid through an invert- ed "U"-shaped tube from one point to another lower point over the barrier created by the inverted "U". SOLIDS-HANDLING The capability of a pump to pass solids of a specific size, such as 3-in. spherical solids. SPECIFIC SPEED An index number used to classify rotational pumps into three basic categories related to their vane and hydraulic configurations. NS = RPM x GPM H 3/4 Glossary of System Terms 129 Glossaries 2/2/06 4:49 PM Page 129 The pump types are radial flow, mixed flow and axial flow. N s = 500 to 4,500 as radial flow N s = 4,500 to 10,000 as mixed flow N s = 10,000 to 15,000 as axial flow SPHERE SIZE The maximum physical diameter of a non-deformable sphere that can pass through the pump without obstruction or interference of any kind from volute entry port to discharge port. STATIC ELEVATION (STATIC HEAD) The vertical distance between the level of the source of supply and the high point in the force main or the level of the discharge to the atmosphere. STORM WATER Surface water from rain, snow, or melting ice which runs out from the surface of a drainage area. It is normally collected in sewers separate from the sanitary sewers, and receives minimal, if any treatment, prior to discharge to a receiving water. When collected in a combined sewer system, the resulting mixture of sanitary sewage and storm water is called combined wastewater. SUBMERGENCE The depth of fluid above the center line of the volute on a verti- cal submersible pump. Requirements will vary depending on the nature of the fluid and the hydraulic configuration of the sump. SUBMERSIBLE PUMPS Submersible wastewater pumps are vertical, close-cou- pled, extra-heavy duty pump-motor units which are designed to operate under the liq- uid they are pumping. They are solids handling, usually have a 3-in. or larger dis- charge, and are also called submersible sewage pumps. Also see Grinder Pumps. SUMP See Wet Well. SYSTEM HEAD CURVE A graph showing the relationship of static head and fric- tion head at various flow rates through a given piping system. TOPOGRAPHY STUDY A study that relates to the shape of the land surface and to the characteristics of the underlying soil and rocks. TOTAL DYNAMIC HEAD (TDH) The difference between the elevation corre- sponding to the pressure at the discharge flange of a pump and the elevation corre- sponding to the vacuum or pressure at the suction inlet of the pump, corrected to the same datum plane, plus the velocity head at the discharge flange on the pump, minus the velocity head at the suction inlet of the pump. The value or quantity used to express the energy content of the liquid per unit height. Expressed on the Y axis of a pump curve. TRIPLEX A pumping station containing three pumps. VALVE BOX A metallic or concrete box or vault containing valving, to allow access for service and maintenance without having to enter the wet well. VAPOR PRESSURE That portion of pressure above atmospheric pressure that is required to maintain a liquid state for a given fluid at a specified temperature. VELOCITY The speed at which a liquid is moving. Usually measured in feet per second. VOLUTE The casing of a centrifugal pump made in the form of a spiral or volute as an aid to the partial conversion of the velocity energy into pressure head as the water leaves the impeller. VORTEX (VORTICES) A revolving mass of water in which the streamlines are concentric circles and in which the total head of each streamline is the same. Glossary of System Terms 130 Glossaries 2/2/06 4:49 PM Page 130 WASTEWATER The spent or used water of a community or industry which con- tains dissolved and suspended matter. WATER HAMMER A series of shocks within a piping system when the flow of liquid is stopped suddenly, with a sound like hammer blows. WET WELL A tank or pit which receives drainage, stores it temporarily, and from which the discharge is pumped. Glossary of System Terms 131 Glossaries 2/2/06 4:49 PM Page 131 132 Glossaries 2/2/06 4:49 PM Page 132 ALTERNATING CURRENT (AC) A current which reverses in regularly recurring intervals of time and which has alternative positive and negative values, and occurring a specified number of times per second. The number is expressed in cycles per second or Hertz (Hz). ALARM LIGHT A light which is used to attract attention when a problem occurs in the system. ALTERNATOR A relay device designed for alternating the run cycle or duplexing action of two or more motors automatically. There are two basic types. One mechani- cally changes its contacts each time the operating coil is de-energized. The second is a solid state unit with an output relay. The alternator is used in the automatic control circuit to the motor starters to rotate the duty cycle of each motor. AMBIENT TEMPERATURE Temperature of the surroundings in which the equip- ment is used or operated. AMMETER Meter for measuring the current in an electrical circuit, measured in amperes. AMPERE The unit of electric current flow. One ampere will flow when one volt is applied across a resistance of one ohm. AUDIBLE ALARM Horn, siren, bell, or buzzer which is used to attract the atten- tion of the operator when a problem occurs in the system. AUXILIARY CONTACTS Contacts of a switching device in addition to the main current contacts that operate with the movement of the latter. They can be normally open (NO) or normally closed (NC) and change state when operated. CAPACITOR A device which introduces capacitance into an electrical circuit. The capacitor, when connected in an alternating current circuit, causes the current to lead the voltage in time phase. The peak of the current wave is reached ahead of the peak of the voltage wave. This is the result of the successive storage and discharge of elec- tric energy. CIRCUIT BREAKER A mechanical switching device capable of making, carrying, and breaking currents under normal conditions. Also making, carrying for a specific time, and automatically breaking currents under specified abnormal circuit conditions, such as those of short circuit. Circuit breakers have an ampere trip rating for normal overload protection and a maximum magnetic ampere interrupting capacity (AIC) for short circuit protection. COMMERCIAL POWER The term applied to power furnished by an electric power utility. CONDENSATION HEATER A device that warms the air within an enclosure and prevents condensation of moisture during shut-down periods. Also known as a space heater. CONDUCTOR A wire, cable or bus bar designed for the passage of electrical current. Glossary Of Electrical Terms 133 Glossaries 2/3/06 10:20 AM Page 133 Glossary of Electrical Terms 134 CONTACTOR An electro-mechanical device that is operated by an electric coil and allows automatic or remote operation to repeatedly establish or interrupt an electrical power circuit. A contactor provides no overload protection as required for motor loads.Sometimes called a power relay. CONTACTS Devices for making and breaking electrical circuits, which are a part of all electrical switching devices. CURRENT The amount of electricity measured in amperes which is flowing in a circuit. CYCLE A given length of time (See Alternating Current). In the U.S., most electric current is 60 cycle (60 Hz). CYCLE TIMER A timer that repeatedly opens and closes contacts according to pre- set time cycles. DELTA CONNECTION A common three phase connection shaped schematically like the Greek Delta. The end of one phase is connected to the beginning of the next phase, or vice versa. DESIGN LETTER A letter that is shown on the motor nameplate indicating NEMA's classification of that motor. Classification encompasses characteristics such as full-voltage starting, locked rotor torque, breakdown torque, and others that determine electrical type. DISCONNECTING MEANS (DISCONNECT) A device or group of devices, or other means whereby all the ungrounded conductors of a circuit can be disconnected simultaneously from their source of supply. ELAPSED TIME METER An instrument used to record the amount of time each pump runs. One elapsed time meter is used per pump. ELECTRIC UTILITIES All enterprises engaged in the production and/or distribu- tion of electricity for use by the public. EMERGENCY POWER (ALTERNATE SOURCE OF POWER) An independent reserve source of electric power which, upon failure or outage of the normal power source, provides stand-by electric power. ENCLOSURE The cabinet or specially designed box in which electrical controls and apparatus are housed. It is required by the National Electrical Code (NEC) to pro- tect persons from live electrical parts and limit access to authorized personnel. It also provides mechanical and environmental protection. An enclosure should be designed to provide the required protection and sized to provide good, safe wire access and replacement of components. It can be manufactured of steel, galvanized or stainless steel, aluminum, or suitable non-metallic materials including fiberglass. EXPLOSION-PROOF MOTOR A motor in a special enclosure. The purpose of the enclosure is twofold: 1) If an explosive vapor (gas) should explode inside the motor, the frame of the motor will not be affected. 2) The enclosure is so constructed that no such explosion will ignite vapors outside the motor. FACTORY MUTUAL (FM) Independent U.S. agency associated with the insurance industry which tests for safety. FREQUENCY The number of complete cycles of an alternating voltage or current per unit of time and usually expressed in cycles per second or Hertz (Hz). Glossaries 2/2/06 4:49 PM Page 134 Glossary of Electrical Terms 135 FULL LOAD CURRENT The greatest current that a motor or other device is designed to carry under specific conditions; any additional is an overload. FULL LOAD AMPS (FULL LOAD CURRENT) The current flowing through a line terminal of a winding when rated voltage is applied at rated frequency with rated horsepower. FUSE An over-current protective device which consists of a conductor that melts and breaks when current exceeds rated value beyond a predetermined time. GENERAL PURPOSE RELAY A relay that is adaptable to a wide variety of appli- cations as opposed to a relay designed for a specific purpose or specific application. GENERATOR A machine for converting mechanical energy into electrical energy or power. GENERATOR RECEPTACLE A contact device installed for the connection of a plug and flexible cord to supply emergency power from a portable generator or other alternate source of power. Receptacles are rated in voltage, amps, number of wires, and by enclosure type. GROUND A connection, either intentional or accidental, between an electric circuit and the earth or some conducting body serving in place of the earth. GROUND FAULT INTERRUPTION (GFI) A unit or combination of units which provides protection against ground fault currents below the trip levels of the breakers of a circuit. The system must be carefully designed and installed to sense low magni- tude insulation breakdowns and other faults that cause a fault ground current path. The GFI system must be capable of sensing the ground fault current and disconnecting the faulted circuit from the source voltage. GROUNDED NEUTRAL The common neutral conductor of an electrical system which is intentionally connected to ground to provide a current carrying path for the line to neutral load devices. GROUNDING CONDUCTOR The conductor that is used to establish a ground and that connects equipment, a device, a wiring system, or another conductor (usually the neutral conductor) with the grounding electrode. HAND-OFF-AUTOMATIC (HOA) Selector switch determining the mode of system operation. H is the hand mode only. 0 is system Off. A is automatic operation, normal- ly with pump alternation. HAZARDOUS LOCATIONS Those areas as defined in the NEC where a potential for explosion and fire exist because of flammable gasses, vapors, or finely pulverized dusts in the atmosphere, or because of the presence of easily ignitable fibers or flyings. HERTZ (Hz) A unit of frequency equal to one cycle per second. HIGH POTENTIAL TEST A test which consists of the application of a voltage higher than the rated voltage between windings and frame, or between two or more windings, for the purpose of determining the adequacy of insulating materials and spacing against breakdown under normal conditions. It is not the test of the conductor insulation of any one winding. HORSEPOWER A method of rating motors whereby values are determined by factors including rotational speed and torque producing capability as well as other fac- tors. IN-RUSH CURRENT See Locked Rotor Current. INTERLOCK Interrelates with other controllers. An auxiliary contact. A device connected in such a way that the motion of one part is held back by another part. Glossaries 2/2/06 4:49 PM Page 135 Glossary of Electrical Terms 136 INTRINSICALLY SAFE A term used to define a level of safety associated with the electrical controls used in some lift stations. Intrinsically safe equipment and wiring is incapable of releasing sufficient electrical or thermal energy under normal or abnormal conditions to cause ignition of a hazardous atmospheric mixture without the need for explosion-proof enclosures in the hazardous area. Any associated devices must be out- side the hazardous area with an approved seal-off fitting used as an isolating barrier. KILOWATT (KW) A unit of measure of electrical power. One kilowatt equals 1000 watts. Used where larger units of electrical power are measured. LOCKED ROTOR CURRENT (See Starting Amps). LOCKOUT A mechanical device which may be set to prevent the operation of a pushbutton or other device. MANUAL TRANSFER SWITCH A switch designed so that it will disconnect the load from one power source and reconnect it to another source while at no time allowing both sources to be connected to the load simultaneously. MEGGER OR MEGOHMETER A high resistance range ohmeter utilizing a power source for measuring insulation resistance. MEGOHM A unit of resistance equal to one million ohms. MOTOR CIRCUIT PROTECTOR A molded case disconnect switch specifically designed for motor circuits. It has a trip unit that operates on the magnetic principle only, sensing current in each of the three poles with an adjustable trip point. It pro- vides short circuit protection, required by the National Electrical Code (NEC). It differs from a standard breaker in that it does not have a thermal overload unit. MOTOR EFFICIENCY A measure of how effectively a motor converts electrical energy into mechanical energy. Motor efficiency is never 100 percent. It is a variable that depends on a given motor's performance. Tabulated at 100, 75 and 50 percent load, it is the ratio of power output to power input. MOTOR, ELECTRIC A rotating device which converts electrical power into mechanical power. MOTOR HORSEPOWER RATING The motor horsepower nameplate rating fully- loaded at the ambient temperature. NEC The National Electrical Code (NEC) is the standard of the National Board of Fire Underwriters for electric wiring and apparatus, as recommended by the National Fire Protection Association. NEC CODE LETTER Motors with 60 and 50 Hertz ratings shall be marked with a code letter designating the locked-rotor KVA per horsepower on 60 Hertz. NEMA National Electrical Manufacturers Association, a non-profit trade association supported by the manufacturers of electrical apparatus and supplies. NEMA promul- gates standards to facilitate understanding between the manufacturers and users of electrical products. NFPA National Fire Protection Association. Sponsors and publishes the National Electrical Code (NEC). NEUTRAL The point common to all phases of a polyphase circuit, a conductor to that point, or the return conductor in a single phase circuit. The neutral in most sys- tems is grounded at or near the point of service entrance only and becomes the grounded neutral. NORMALLY OPEN and NORMALLY CLOSED The terms "Normally Open" and "Normally Closed" when applied to a magnetically operated switching device such Glossaries 2/2/06 4:49 PM Page 136 Glossary of Electrical Terms 137 as a contactor or relay, or to the contacts thereof signify the position taken when the operating magnet is de-energized. These terms pertain to all switches. OHM Unit of electrical resistance. One volt will cause a current of one ampere to flow through a resistance of one ohm. OHMMETER A device for measuring electrical resistance expressed in ohms. OVERLOAD PROTECTION Overload protection is the effect of a device operative on excessive current, but not necessarily on short circuit, to cause and maintain the interruption of current flow to the device being governed. Re-set may be manual or automatic. OVERLOAD RELAY A relay that responds to electric load and operates at a pre- set value of overload. The unit senses the current in each line to the motor and is either bimetallic, melting alloy or solid state actuated. It may be of the non-compensat- ed or ambient-compensated type, and of a standard or fast-trip design. PHASE (THREE PHASE CIRCUIT) A combination of circuits energized by alter- nating electromotive forces which differ in phase by one-third of a cycle (120 degrees). In practice, the phases may vary several degrees from the specified angle. PHASE MONITOR A device in the control circuit of motors which monitors the three phase voltage and protects against a phase loss (single phasing), under voltage (brown outs) and phase reversal (improper phase sequence). Most are adjustable to set the nominal voltage and some have a LED indicator to indicate acceptable voltage and phase conditions. The output contacts are used to control the motor starters and pro- vide signaling for telemetering. PILOT DEVICE Directs operation of another device: Float switch A pilot device responding to liquid levels. Limit switch A pilot device operated in response to a mechanical operation. Pressure switch A pilot device operated in response to pressure levels. Temperature switch A pilot device operated in response to temperature values. All of the above switches cause a contact change of the switch at pre-set or adjustable points. PILOT LIGHT A lamp available with various colored lenses designed to operate on a control voltage. They are each turned On and Off to provide the required indication for specific functions or alarm conditions. They are available in various sizes and volt- age ratings. They are each designed for a specific bulb style and base configuration and some have an integral transformer to allow the use of low voltage bulbs. Full volt- age incandescent bulbs are most common, but neon bulbs are also used. POWER FACTOR The ratio of the true power to the volt-amperes in an alternating current circuit. Power factor is expressed in a percent of unity either lagging for induc- tive loads or leading for capacitive loads. Resistive loads produce a unity power factor. PUSHBUTTON Part of an electrical device, consisting of a button that must be pressed to effect an operation. RATED VOLTAGE The voltage of electrical apparatus at which it is designed to operate. REDUCED VOLTAGE AUTO-TRANSFORMER STARTER A starter that includes an auto-transformer to furnish reduced voltage for starting an alternating current motor. It includes the necessary switching mechanism. This is the most widely used reduced voltage starter because of its efficiency and flexibility. RELAY An electric device that is designed to interpret input conditions in a pre- Glossaries 2/2/06 4:49 PM Page 137 Glossary of Electrical Terms 138 scribed manner and, after specified conditions are met, to respond and cause contact operation or similar abrupt changes in associated electric control circuits. RELAY, ELECTROMAGNETIC A relay controlled by electromagnetic means, to open and close electric contacts. RELAY, SOLID STATE A completely electronic switching device with no moving parts or contacts. RPM Revolutions per minute of the motor/pump rotating assembly. REMOTE CONTROL Control function initiation or change of electrical device from a remote point. RESISTANCE The non-reactive opposition which a device or material offers to the flow of direct or alternating current. Usually measured in ohms. SAFETY SWITCH An enclosed, manually-operated disconnecting switch, which is horsepower and current rated. Disconnects all power lines simultaneously. SEAL FAILURE ALARM The sensing and indication of the intrusion of water into the oil-filled seal chamber between the inner and outer shaft seal of a submersible pump. SELECTOR SWITCH A multi-position switch which can be set to the desired mode of operation. SERVICE FACTOR A safety factor designed and built into some motors which allows the motor, when necessary, to deliver greater than its rated horsepower. SINGLE PHASE A circuit that differs in phase by 180 degrees. Single phase cir- cuits have two conductors, one of which may be a neutral, or three conductors, one of which is neutral. STANDBY POWER SUPPLY The power supply that is available to furnish electric power when the normal power supply is not available. STAR CONNECTION Same as a "Y" or "Wye" connection. This three-phase con- nection is so called because, schematically, the joint of the "Y" points looks like a star. STARTER A device used to control the electrical power to motors and provide overload protection as required by the NEC. The starter can be operated manually, electrically, or by automatic pilot devices. A starter has two basic parts a contactor for power switching and an overload relay for protection. STARTING AMPS (LOCKED ROTOR) The maximum current drawn by the motor during the starting period. STARTING RELAY A relay actuated by current, voltage or the combined effect of current and voltage which is used to perform a circuit-changing function in the primary winding of single phase induction motor within a pre-determined range of speed as the motor accelerates; and to perform the reverse circuit-changing operation when the motor is disconnected from the supply line. One of the circuit changes that is usually performed is to open or disconnect the auxiliary winding (starting) circuit. SUBMERSIBLE MOTOR A motor whose housing and terminal box is so designed that the motor can run underwater completely submerged at an allowable tempera- ture. SURGE ARRESTER A protective device for limiting surge voltages on equipment by discharging or bypassing surge current; it prevents continued flow of follow current to ground, and is capable of repeating these functions as specified. SWITCH A device for making, breaking, or changing connections in a circuit. Glossaries 2/2/06 4:49 PM Page 138 TELEMETERING The transmitting of alarm and control signals to and from remote lift station controls and a central monitoring location. TERMINAL BLOCK An insulating base equipped with terminals for connecting wires. THERMAL OVERLOAD PROTECTOR Device, either a bimetal element or elec- tric circuit, which protects motor windings from excessive temperature by opening a set of contacts. This device may reach its pre-set trip point as a result of ambient tem- perature, current, or both. May be automatic or manually set. THREE PHASE CIRCUIT A combination of circuits energized by alternating elec- tromotive sources which differ in phase by one third of a cycle that is, 120 degrees. A three phase circuit may be three wire or four wire with the fourth wire being con- nected to the neutral point of the circuit which may be grounded. TIME CLOCK A device used to schedule electrical On/Off cycling operations. The device may be solid state or mechanical designed using a synchronous motor. The cycling operation must be programmed manually. The time clocks may operate in any increments of days, weeks, minutes, or hours. TIME DELAY RELAY (TDR) A device with either mechanical or solid state out- put contacts that performs a timing function upon energization or control signal. TRANSDUCER A device to condition and transform an analog signal to a specific variable output electrical signal proportional to the input signal. Typical inputs include variable pressure, level, voltage or current. Some common outputs are O to 1ma, 4 to 20 ma, and various MVDC signals. A transducer must be specifically designed to be compatible with the input/output requirements of the total system. TRANSFORMER A static electric device consisting of a single winding, or two or more coupled windings, used to transfer power by electromagnetic induction between circuits at the same frequency, usually with changed values of voltage and current. UNDERWRITERS LABORATORIES, INC. (UL) An independent, non-profit U.S. organization that tests products for safety. VFD Variable frequency drive. VOLTAGE (NOMINAL A) A nominal value assigned to a circuit or system for the purpose of conveniently designating its voltage class (as 120/240, 480/240, 600, etc.). The actual voltage at which a circuit operates can vary from the nominal within a range that permits satisfactory operation of equipment. VOLTMETER An instrument for measuring voltage. WATT A unit of measure of electrical power. WYE CONNECTION See Star Connection. Glossary of Electrical Terms 139 Glossaries 2/2/06 4:49 PM Page 139 140 Glossaries 2/2/06 4:49 PM Page 140 Appendixes 141 Appendixes 2/3/06 10:19 AM Page 141 142 Appendixes 2/2/06 4:50 PM Page 142 143 Appendixes 2/2/06 4:50 PM Page 143 144 Appendixes 2/2/06 4:50 PM Page 144 145 Chart reproduced with permission from Franklin Electric. Appendixes 2/2/06 4:50 PM Page 145 146 Reproduced with permission from Killark Electrical Manufacturing Company. Appendixes 2/2/06 4:50 PM Page 146 147 Reproduced with permission from AASHTO Standard Specification for Highway Bridges 13th Edition, 1983. Appendixes 2/2/06 4:50 PM Page 147 148 Appendixes 2/2/06 4:50 PM Page 148 149 Appendixes 2/2/06 4:50 PM Page 149 150 Appendixes 2/2/06 4:50 PM Page 150 151 Appendixes 2/2/06 4:50 PM Page 151 152 Appendixes 2/2/06 4:50 PM Page 152 153 Appendixes 2/2/06 4:50 PM Page 153 154 Appendixes 2/2/06 4:50 PM Page 154 155 Appendixes 2/2/06 4:50 PM Page 155 156 Appendixes 2/2/06 4:50 PM Page 156 157 Appendixes 2/2/06 4:50 PM Page 157 158 Appendixes 2/2/06 4:50 PM Page 158 159 Appendixes 2/2/06 4:50 PM Page 159 160 Appendixes 2/2/06 4:50 PM Page 160 The Submersible Wastewater Pump Association (SWPA) has developed a Standardized Presentation Format for Pump and Motor Characteristics of a pump or family of pumps. The required information included in the presentation format is the minimum data need- ed by a specifier or designer to adequately evaluate using a specific submersible waste- water pump for a specific application. By using the SWPA Standardized Presentation Format, pump manufacturers present data in a consistent format so the designer or specifier can make an informed comparison between different brands or types of equipment. A major component of the presentation format is a series of SWPA Standardized Pump/Motor Definitions developed by the Association. They define the terms that the data represent. SWPA members may use the Associations logo with the designation Approved Curve and Data Format in conjunction with statements that their performance curve(s) provide a minimum number of data categories and the minimum design information as recom- mended by the Association. Pump manufacturers, at their discretion, may include addi- tional information. SWPA assumes no responsibility for any other manufacturer claims made relating to the pump performance curves or for the correctness of the information presented. The following statement is to be included on any performance curve carrying the SWPA Member Logo. "SWPA Data Categories Presented Data on this sheet supply design informa- tion as the minimum recommended by the Submersible Wastewater Pump Association (SWPA) and is defined in accordance with SWPA's Standardized Definitions for Pump and Motor Characteristics. The accuracy of the data is the responsibility of (company name). At the pump manufacturers choice, the presentation may be in a one (1) or two (2) page format, including a performance curve(s) and the minimum pump and motor data as recommended by SWPA. Each company seeking approval to use the Approved Curve and Data Format logo, is requiured to file a formal application which includes a Statement of Compliance, attest- ing that the companys Chief Engineer or Technical Manager: Has reviewed our perfor- mance curve(s) and appropriate minimum data as prescribed by SWPA and to the best of our ability and knowledge all sheets for which we are seeking approval to display the SWPA Member Logo are in compliance with the SWPA recommendations for minimum data to be included and that the data is presented as defined by SWPA's Standardized Pump/Motor Definitions. Each application and the accompanying curve and data presentation is reviewed by the Associations Technical Committee to insure that the minimum data and information are included. Those that meet the miniumum requirements are then permitted to use the logo and accompanying language, indicating conformance with the Standardized Presentation Format. 161 SWPAs Standardized Presentation Format for Pump and Motor Characteristics Afterward section 2/2/06 4:51 PM Page 161 The Standardized Pump/Motor Definitions presented here were developed by members of the Submersible Wastewater Pump Associations Technical Committee. Members of the Committee included knowledgeable specialists from submersible pump and accessory companies. Pump Hydraulic Efficiency: Expressed as a percentage of liquid horsepower to brake horsepower over the recommended operating range of the indicated impeller size(s). Brake Horsepower (BHP): The power delivered to the pump shaft under stated operating conditions of the pump where horsepower is 550 foot/pounds per second, expressed by graph or figured by: BHP = Q x H x S.G. where: K x Eff. Q = Capacity in U.S. GPM H = Head in Feet S.G. = Specific Gravity (1.0 for water) K = 3960 Eff. = Pump Hydraulic Efficiency Motor Horsepower Rating: The motor horsepower nameplate rating fully-loaded at the ambient temperature. RPM: Nominal revolutions per minute of the motor/pump rotating assembly. GPM: The volume delivered at the pump discharge flange expressed in gallons per minute (GPM). Plotted on the X axis of a curve. Also referred to as capacity. TDH: Total Dynamic Head. The value or quantity used to express the energy content of the liquid per unit height. Plotted on the Y axis of a curve. Discharge Diameter: The inside diameter of the discharge port of the pump as measured at the integrally cast discharge flange to the pump casting (volute). Impeller Diameter: The concentric outside diameter as measured radially of the pump impeller. Sphere Size: The maximum physical diameter of a non-deformable sphere that can pass through the pump from volute entry port to discharge port without obstruction or interference of any kind 162 Standardized Pump/Motor Definitions Afterward section 2/2/06 4:51 PM Page 162 Motor Characteristics (Motor characteristics terms are as defined by NEMA Motors and generators No. MGI-1978, NEC-1990, IEEE Std. 100-1992, with the exception of full- load amps). Electrical Motor Terms: A. Horsepower: A system of rating motors whereby horsepower values are determined, for various synchronous speeds, from the minimum value of breakdown torque that the motor design will provide. B. Starting Amps (Locked Rotor): The maximum current drawn by the motor during the starting period. C. Phase (Three-phase circuit): A combination of circuits energized by alternating electro- motive forces which differ in phase by one-third of a cycle (120 degrees). In practice, the phases may vary several degrees from the specified angle. D. Hertz (Hz): A unit of frequency equal to one cycle per second. E. NEC Code Letter: Motors with 60 and 50 Hertz ratings shall be marked with a code letter designating the locked-rotor kVA per horsepower on 60 Hertz. F. Voltage (Nominal ): A nominal value assigned to a circuit or system for the purpose of conveniently designating its voltage class (as 120/240, 480/240, 600, etc.). The actual voltage at which a circuit operates can vary from the nominal within a range that permits satisfactory operation of equipment. G. Design Letter: A letter that is shown on the motor nameplate indicating NEMA's classification of that motor. Classification encompasses characteristics such as full-volt- age starting, locked rotor torque, breakdown torque, and others that determine electri- cal type. H. Revolutions Per Minute (RPM): The number of revolutions a given shaft makes in one minutes time I. Full Load Amps (Full load current): The current flowing through a line terminal of a winding when rated voltage is applied at rated frequency with rated horsepower. 163 Afterward section 2/2/06 4:51 PM Page 163 164 Afterward section 2/2/06 4:51 PM Page 164 165 A Access covers 9,11, 105-106, 109-111 Affinity Laws (Pump) 28, 33, 90 Alarm systems 9, 83-84 Allowable Operating Range (AOR) 89 Average daily flow 13-14, 40 Axial flow 30, 130 B Ball valve 102-103 Brake horsepower 28, 44, 49, 127, 129, 162 Bubbler (air) systems 77, 79 Bubbler systems 80, 84 Built-in-place stations 5-6, 8 C Cavitation 33-34, 93 Centrifugal pumps 27, 30, 32-34, 40 Check valves 56, 101-102, 104-105, 110, 115 Cleansing velocity 63 Closed loop cooling system 58-59 Control panel enclosures 69, 86 Control panel 9, 11, 17, 54, 59-60, 63-64, 69, 72-75, 79, 82, 84-87, 109-110, 112- 115, 119, 123, 128 Current source inverter 95-96 Cutwater 31-32 D Design periods 13 Diaphragm type switches 79 Discharge size 1, 6, 8, 61, 93, 127, 129 Dry well submersible pumps 53-60 Duplex stations 5-6, 82 E Electrode level sensing systems 80 External coolant feed 59 F Float switches 77-79, 81, 124-125 Flow 5-6, 8-9, 11, 13-18, 21, 23-30, 32-34, 36-37, 39-40, 43-46, 50, 53, 55-57, 59, 61- 62, 65, 67, 70, 74-75, 77, 79-80, 82, 89- 94, 97, 99-104, 111, 115, 127-131, 133- 135, 137, 138, 163 Francis type impeller 29 Friction head 36, 43-44, 130 Friction losses 33, 37, 39, 62-63, 97 G Gate valves 103 Grinder pumps ix, 1, 3, 7, 61-68, 79, 86- 87, 128, 130 Ground fault interruptors Guide rail systems 3-4, 107, 129 H Hazardous area applications 81 High water alarm 83 L Leakage losses 33 Level control systems 60, 77, 81 Liquid level controls 4, 80, 114, 128 M Maximum daily flow 14 Mechanical losses 33 Mechanical shaft seals 35 Medium lift stations 23 Index Afterward section 2/3/06 10:18 AM Page 165 166 Minimum daily flow 13-14 Mixed flow impeller 29 Motor and motor cavity 35 Motor controllers 69, 74-75 Motors 8, 17, 36 58, 60, 74-77, 83, 86-87, 90, 94, 96-97, 118, 120, 123, 133, 135- 138, 163 N Natural convection cooling 59-60 Net positive suction head 4, 25, 33, 128 O Operation sequences 82 P Peak hourly flow 13-14 Plug valves 102-103 Population growth projections 13 Power factor 91, 137 Power failure alarm 83 Prefabricated stations 6, 8 Preferred Operating Range (POR) 89, 92 Pressure sewers ix, 16, 61-68 Pressure transducers 77, 81 Primary power sources 69 Propeller-type impeller 29 Pump affinity laws 28, 33, 90 Pump cycle volumes 24 Q Quick-disconnect sealing flange 9 R Radial type impeller 29 Reduced voltage starters 75-76 Redundant Off level with alarm 83 S Seal failure alarm 83, 138 Septic Tank Effluent Pump (STEP) 13, 16- 17 Shock losses 27, 33 Shut-off valves 9, 101-102, 104-105, 110 Siphoning 33-34 Specific speed 29-30, 33, 129 Speed range 29-30, 92-93, 96 Strainers 105 Submergence 24, 33-34, 36, 60, 80, 83, 116, 130 T Theoretical head 27-28 Total dynamic head 36-37, 51, 130, 162 Trash baskets 105 U Ultrasonic transducers 77, 80 V Variable frequency drives 1, 8, 76-77, 89, 93, 95 Variable speed controllers 77 Variable speed pumping ix, 1, 89-100 Variable voltage input 95 VFD Types 95 Vortexing 21, 33-34 W Wastewater flow 13-16 Water hammer 56-57, 100, 104-105, 131 Wiring cable entry 36 Afterward section 2/2/06 4:51 PM Page 166 Submersible Sewage Pumping Systems (SWPA) Handbook Third Edition Prepared by a task force of knowledgeable specialists, the Submersible Sewage Pumping Systems (SWPA) Handbook is intended to familiarize and assist those responsible for design- ing, installing, and operating lift stations using submersible solids handling pumping sys- tems. The SWPA Handbook emphasizes the design, construction, installation, and operation of a system of carefully integrated components (The Systems Approach). Submersible wastewater pump stations contain a number of complex interdependent components that must be properly matched to each other to ensure long, satisfactory, and economic life. This approach assists consulting engineers, specifiers, users, and others gain a better understanding of the interaction between the pump, valves, control panels, VFDs, basins, mechanical seal materials, and other components and how they interact to create a sys- tem that will create optimum performance, minimum maintenance, and long life. This Handbook is intended to be used as a daily reference. It presents fundamentals. It also addresses some of the more sophisticated aspects of submersible wastewater pump systems and their components. To make this publication more useful, two glossaries are included: The first is a glossary of system terms; the second is a glossary of electrical terms. Also included is a variety of resource materials, including friction loss tables for various pipe and fitting configurations. In total, this publication includes more than 80 tables, charts, diagrams, photographs and other visuals to greatly enhance its value and provide added convenience for the reader. Finally, SWPAs Standardized Presentation Format for Pump and Motor Characteristics, is included. The required information included in the presentation format is the minimum data needed by a specifier or designer to adequately evaluate using a specific submersible wastewater pump for a specific application. By using the SWPA Standardized Presentation Format, pump manufacturers present data in a consistent format so the designer or specifier can make an informed comparison between different brands or types of equipment. Current information about submersible pump manufacturers and manufacturers of com- ponent parts and accessory items for submersible sewage lift stations is included in the SWPA Membership Roster and Product Reference Guide. For a free copy, contact SWPA headquarters, 1866 Sheridan Road, Suite 201, Highland Park, IL 60635-2545, USA. Phone: 847-681-1868. FAX: 846-681-1869. For additional information about the Association, its services, activities, membership benefits, training programs, and technical resources, visit the SWPA web site at www.swpa.org.net. SWPA Handbook cover 2/2/06 5:03 PM Page 2