Test details as per ASTM A343 - 97 Units SI

Enter data for reference purpose


File name

Date

remark

Specimen ID

GP-4

Thickness

Type of material

0.5

GP-4

Test Temperature in C

Details of specimen , Device and calculation base


Weight in gram Density per CM
420

7.75

Length in mm

Frequency In
Hz.

Device

Turns

Assumed % Eddy Current

305

50

Epstein Bridge

700

30

Collected Data
Flux Density in Flux Voltage Set
Tesla

RMS Voltage

RMS Amp

Peak Amp

Watt

Actual Fv

Actual Hz.

6.90750

6.92284

0.134955

0.170453

0.75832

6.90665

50

1.1

7.59825

7.61925

0.151369

0.212967

0.89659

7.59901

50

1.2

8.28900

8.31618

0.176207

0.285882

1.05086

8.28899

50

1.3

8.97975

9.01879

0.219328

0.40996

1.2277

8.98048

50

1.4

9.67049

9.72849

0.304865

0.645722

1.43128

9.67062

50

1.5

10.36124

10.45734

0.494751

1.1423

1.65832

10.36089

50

1.6

11.05199

11.23288

0.938643

2.226384

1.89322

11.05227

50

1.7

11.74274

12.12738

2.038335

4.749029

2.12903

11.74316

50

1.8

12.43349

13.22417

4.47282

9.730063

2.3407

12.43282

50

TEST REPORT UNIT SI


As per ASTM A-343 - 97 Tested on 25 cm Gopal make Epstein Tester
Date
Specimen ID
File Name

GP-4

Orientation

Width of Strips (mm)

Strips Condition

Weight (Grams)

420

Thickness of Strips (mm)

0.5

Density (gm/cm3)

7.75

Type of Material

GP-4

Strip Length (mm)

305

Assumed % Eddy Current

30

Gopal Electronics

Owner Name

TEST RESULTS
Flux Density
in Tesla

Watt / Kg.

VA / Kg.

Hz ac
magnetizing
force A/m

Hp Peak
magnetizing
force A/m

ac
Permeability

Peak
Permeability

Form Factor

0.9999

2.339

2.886

142.1

126.9

5598

6268

1.113

1.1001

2.765

3.563

159.4

158.6

5492

5520

1.114

1.2000

3.239

4.527

185.6

212.9

5146

4486

1.114

1.3001

3.782

6.111

231.0

305.3

4479

3389

1.116

1.4000

4.405

9.163

321.1

480.9

3470

2317

1.117

1.4999

5.094

15.985

521.0

850.6

2291

1403

1.121

1.6000

5.790

32.579

988.5

1657.9

1288

768

1.129

1.7001

6.447

76.385

2146.6

3536.5

630

383

1.147

1.7999

6.955

182.778

4710.5

7245.8

304

198

1.181

Test Parameter
Test Temperature in C
Test Frequency
Form Factor Correction Used

Comments
Checked By

Peak Current Measuring Device = Ammeter


50

Primary = Secondary Turns

Yes
No thanks

Authorized By

700

B/W
1.9
1.8
1.7

Flux Density / Tesla

1.6
1.5
1.4
1.3
1.2
1.1
1
0.9
0

4
Iron Loss W/Kg.

B/VA
1.9
1.8
1.7

Flux Density / Tesla

1.6
1.5
1.4
1.3
1.2
1.1
1
0.9
0

20

40

60

80

100
Iron Loss VA/Kg.

120

140

160

180

200

B/H rms
1.9
1.8
1.7

Flux Density / Tesla

1.6
1.5
1.4
1.3
1.2
1.1
1
0.9
0

500

1000

1500

2000

2500

3000

ac magnetizing force A/m

3500

4000

4500

5000

B/H peak
1.9
1.8
1.7

Flux Density / Tesla

1.6
1.5
1.4
1.3
1.2
1.1
1
0.9
0

1000

2000

3000

4000

5000

Peak magnetizing force A/m

6000

7000

8000

B/ac permeability
1.9
1.8
1.7

Flux Density / Tesla

1.6
1.5
1.4
1.3
1.2
1.1
1
0.9
0

1000

2000

3000
ac permeability

4000

5000

6000

B/Peak Permeability
1.9
1.8
1.7

Flux Density / Tesla

1.6
1.5
1.4
1.3
1.2
1.1
1
0.9
0

1000

2000

3000

4000

Peak permeability

5000

6000

7000

Вам также может понравиться