Вы находитесь на странице: 1из 40

TS5 9 0

In tru d e r Ala rm C o n tro l Pa n e l


O p e ra to rs M a n u a l
1 A
D
C
B
2 3
7
6 5 4
8 9
0 ENT ESC
_
~
SYSTEM OPEN
17:30 01 Jan
SILENT ZONE OMIT
CHIME NEWCODE 24 Hr OMIT
WALK TEST BELLTEST Part Set
Part Set
Part Set
RESET
1 A
B
C
D
2 3
4 5 6
7
ENT ESC
8
0
9
Sett ing the Syst em
Ent er your passcode XXXX
then l eave the protect ed a re a.
Unsetting the System
Go di r ect ly to t he keypad and
en ter you r passcode XXXX.
Resetting
Ent er your passcode XXXX f oll owed
by ENT then 3. Tel ephone your al ar m
compan y and foll ow thei r i nstr uct ions.
!
See User Manual
FULLSET
2
Co nte nts
Syste m O ve rvie w
Introduction . . . . . . . . . . . . . . 3
Remote Keypads. . . . . . . . . . . . 4
O p e ra tin g Yo u r Ala rm Syste m
Introduction . . . . . . . . . . . . . . 5
Passcodes . . . . . . . . . . . . . 5
User Types. . . . . . . . . . . . . . 5
User Menus . . . . . . . . . . . . . 5
Banner Message . . . . . . . . . . 5
Engineer on site. . . . . . . . . . . 5
Full Setting The System . . . . . . . . . 6
Unsetting the system . . . . . . . . . . 7
Part Setting The System. . . . . . . . . 8
Unsetting After an Alarm . . . . . . . . 9
Resetting After an Alarm . . . . . . . 10
User Reset . . . . . . . . . . . . . 10
Engineer Reset. . . . . . . . . . . 10
Remote Reset . . . . . . . . . . . 11
U se r M e n u 1
Introduction. . . . . . . . . . . . . . 12
Bell Test . . . . . . . . . . . . . . . . 13
Walk Test . . . . . . . . . . . . . . . 14
Remote Reset. . . . . . . . . . . . . 14
Change Passcode . . . . . . . . . . 15
Enable Chime . . . . . . . . . . . . 16
Isolate/Re-instate Shunt Group . . . . 17
Isolating a Shunt Group . . . . . . 17
Re-instating a Shunt Group . . . . 17
Omit Circuits . . . . . . . . . . . . . 18
Silent Set . . . . . . . . . . . . . . . 19
Full Set and Part Set. . . . . . . . . . 19
U se r M e n u 2
Introduction. . . . . . . . . . . . . . 20
View Circuits . . . . . . . . . . . . . 21
Set Clock . . . . . . . . . . . . . . . 22
Set Date . . . . . . . . . . . . . . . 23
Setup New Users . . . . . . . . . . . 24
User Types . . . . . . . . . . . . . 24
Alter Chime Circuits. . . . . . . . . . 26
Alter Shunt Group . . . . . . . . . . . 27
Print System Log. . . . . . . . . . . . 28
Set-up Part Sets . . . . . . . . . . . . 29
View Log . . . . . . . . . . . . . . . 30
Log Event Codes . . . . . . . . . . . 31
Enable Remote Service. . . . . . . . 33
Initiate Service Call . . . . . . . . . . 34
Circuit Text . . . . . . . . . . . . . . 35
Fa u lt Fin d in g
Display Messages. . . . . . . . . . . 36
Syste m R e c o rd s
User Record. . . . . . . . . . . . . . 38
Detection Circuit Record . . . . . . . 38
Service Record . . . . . . . . . . . . 39
System Details . . . . . . . . . . . . 40
Installer Information. . . . . . . . . . 40
Syste m Ove r vie w
In tro d u c tio n
The TS590isanadvanced securityalarmcontrol systemsusing state of the artelectronics
to provide comprehensive but flexible protection for both domestic and commercial
premises. The systemcomprises of a number of components linked to a central control
unitwhichisconcealedfromviewbutaccessibleformaintenance. TheTS590canmonitor
from 6 to 14 detection circuits.
Bothsystemscanbe operated fromup to fourremote keypadswhichmaybe one of four
types. Detection devices such as door contacts or movement sensors are allocated to
detection circuits which are identified on the remote keypad displays.
A modemcan also be connected to the alarmsystemvia the telephone line to allow
remote interrogation, programming and resetting of alarms. This feature is known as
Downloadingandisnormallyperformedbytheinstallationcompanyorcentralstation.
Each alarminstallation is specific to the site and its occupier and may differ fromother
TS590 installations. This manual describes in detail all the functions and procedures
available to the user, however, notall these maybe relevantto the wayyoursystemisset
up. To avoid unnecessaryoperating errorsplease discussthe detailsof the alarmsystem
withyourinstallationcompanybefore attempting to use it. Also ensure thatthe installation
company complete the system record sheets at the back of this manual.
3
R e m o te Ke yp a d s
Your alarmsystemcan be operated fromone or more remote LCDkeypads, which will
have been strategically located within the protected premises.
The LCDremote keypad isa full function keypad and can be used to program, test, set
and unset the alarm system.
LC D D isp la y - Used to showthe system
timealongwithothersystemmessages.
G re e n Po we r In d ic a to r - Flashes if no
mains power is present. Steady when
mains power is present.
R e d F u n c ti o n I n d i c a to r - Can be
programmed by the alarm company,
to indicate a fault, set or part-set etc.
K e y b o a rd - Used for operating your
alarm system.
C o ve r - Fold-down cover with quick
guide operating instructions.
4
1 A
D
C
B
2 3
7
6 5 4
8 9
0 ENT ESC
_
~
SYSTEM OPEN
17:30 01 Jan
SILENT ZONE OMIT
CHIME NEW CODE 24 Hr OMIT
WALK TEST BELL TEST Part Set
Part Set
Part Set
RESET
1 A
B
C
D
2 3
4 5 6
7
ENT ESC
8
0
9
Sett ing the Syst em
Ent er your passcode XXXX
then leave the protect ed area.
Unsetting the System
Go direct ly to t he keypad and
enter your passcode XXXX.
Resetting
Ent er your passcode XXXX f ollowed
by ENT then 3. Telephone your alarm
company and follow their instruct ions.
!
See User Manual
FULL SET

Op e ra ting Yo ur Ala rm Syste m


In tro d u c tio n
Pa ssc o d e s
Accessto the systemisgained byentering a 4digit passcode. Everytime youwishto use
the system your passcode must be entered correctly.
U se r Typ e s
TheTS590canhaveupto15separateuserseachuserisassigneda passcode, anda user
level. Theuserlevel defineswhattheusercanaccesswithintheusermenus, fora definition
of each user level se e Se t-up Ne w Use rs p a g e 2 4 .
U se r M e n u s
The systemhas 2 users menus, with each menu having between 9 and 10 options. User
menu1isaccessed byentering yourpasscode followed bythe [ENT] key. Accessto user
menusand optionswill depend on youruserlevel. When a menu option isselected you
mayabandontheoptionbypressingthe[ESC]key. Toleavetheusermenusandreturnthe
systemtoitsoriginalstatesimplykeeppressingthe[ESC]keyuntilthedisplayshowsOPEN.
Ba n n e r M e ssa g e
The bannermessage isnormallyshownonthe top line of displaywhenthe systemisunset
or full set. This message is configured by your alarm company and is usually set to the
alarm company's name.
En g in e e r o n site
When your alarmcompany has an engineer on site and is logged into the system, the
keypadswill showENGINEERONSITE. Youcancontinue to operate the systemasnormal,
if required. The message is automatically cleared when a user passcode is entered.
5
Fu ll Se ttin g Th e Syste m
The full setting procedure can be initiated fromanyremote keypad (if more than one is
fitted). Before attempting to full set the alarmsystemensure that all movement detectors
are unobstructed and all doors, and windows are secure.
1 . Fromthe unset (open) mode enter
your passcode.
2 . After5secondsthe exitsounderwill
start and the display will show the
remaining exit time.
3 . Leave the premises by the
designated exit route, close the
final door and press the exit
terminator button (if fitted). The
system is fully set when the exit
sounder stops.
w
To a b a nd o n the se tting p ro c e ss a ny tim e , sim p ly re -e nte r yo ur p a ssc o d e .
w
If the d isp la y sho w s 9 9 9 9 " a t ste p 2 the syste m is c o nfig ure d se t b y e xit
te rm ina to r o r o n c lo sure o f the la st e xit c irc uit.
w
If a n a tte m p t is m a d e to full se t the syste m w hilst o ne o r m o re c irc uits a re
a c tive (suc h a s a d o o r b e ing o p e n) the d isp la y a t ste p (2 ) w ill ind ic a te the
c irc uit(s) tha t a re in fa ult a nd inte rna l so und e r g e ne ra te s a n inte rrup te d
to ne . The fa ult m ust b e c le a re d b e fo re the se tting p ro c e d ure c a n b e
c o m p le te d . If the fa ult is still p re se nt a t the e nd o f the e xit tim e a n inte rna l
a la rm w ill b e g e ne ra te d . If fitte d , the e xte rna l stro b e lig ht w ill fla sh ind ic a ting
tha t the syste m ha s Fa ile d to se t . To p re ve nt this a la rm sim p ly re -e nte r yo ur
p a ssc o d e b e fo re the e xit tim e r e xp ire s.
6
SYSTEM OPEN
17:30 01 Jan
Press ENT to
Select Functions
Please Exit Now.
Time left > 0035
SYSTEM SET
17:31 01 JAN
? ? ? ?
LC D R e m o te
1
2
3
NOTES
U n se ttin g th e syste m
The unsetting of the alarm system can be performed at any remote keypad.
1 . Enterthepremisesvia theprescribed
entry route and proceed directly to
the remote keypad. The internal
sounders generate an interrupted
tone. The display will show the
remaining entry time.
2 . Enter your 4 digit passcode before
the entry timer expires. The internal
sounderswill stop and the displaywill
showSYSTEMOPEN. After5seconds
the SYSTEM OPEN message will
disappear and the display will show
thetime, (dateandbannertext, LCD
only).
w
If the e ntry tim e is e xc e e d e d a n a la rm is g e ne ra te d fro m the inte rna l
so und e rs a nd the Se c o nd Entry tim e r is sta rte d . If a t the e nd o f the Se c o nd
Entry tim e r the a la rm syste m ha s no t b e e n unse t a full a la rm c o nd itio n w ill
o c c ur. If the a la rm c o m p a ny ha s se t the Se c o nd Entry tim e r to ze ro the full
a la rm w ill o c c ur w he n the first e ntry tim e r e xp ire s.
w
If d uring the e ntry p ro c e d ure the use r stra ys fro m the p re sc rib e d e ntry ro ute
a nd a c tiva te s a d e te c tio n c irc uit a full a la rm w ill o c c ur (inte rna l so und e rs
a nd e xte rna l so und e rs). If the a la rm syste m is fitte d w ith a re m o te sig na lling
d e vic e this w ill a lso b e trig g e re d .
w
The a la rm syste m c a n b e p ro g ra m m e d w ith a n Ab o rt fe a ture w hic h w ill
a llo w the syste m to tra nsm it a n a b o rt sig na l to yo ur a la rm re c e iving c e ntre .
O n re c e iving this sig na l yo ur a la rm re c e iving c e ntre w ill c a nc e l a ny p o lic e
a c tio n. This fe a ture is c o ntro lle d b y a tim e d e la y (no rm a lly se t to 9 0
se c o nd s). Fo llo w ing a full a la rm c o nd itio n yo u m ust e nte r yo ur p a ssc o d e
w ith this tim e p e rio d in o rd e r to se nd the a b o rt sig na l, if yo u fa il to e nte r yo ur
p a ssc o d e b e fo re the tim e r e xp ire s p o lic e a c tio n w ill b e ta ke n.
7
SYSTEM OPEN
17:30 01 JAN
Enter Your Code
Time left > 0015
? ? ? ?
1
2
LC D R e m o te
NOTES
Pa rt Se ttin g Th e Syste m
The TS590 can have up to three predefined part set configurations. Each configuration
allows the alarm system to set with one or more circuits isolated. Normally the alarm
companywill configureeachpartsetoption, howeverthemasterusermayalsoconfigure
the part sets, providing the alarmcompanyhasprogrammed the alarmsystemto allow
this facility.
1 . Fromthe unset (open) mode enter
your passcode.
2 . Select the required part set mode
by pressing [A], [B] or[C].
3 . Eitherpress[ENT] whenthe display
shows the required part set mode
or wait for 5 seconds after which
the exit sounder will start and the
displaywill showthe remaining exit
time.
4 . Leave the area bythe designated
exit route, close the final door and
press the exit terminator button (if
fitted). The systemis part set when
the exit sounder stops.
8
SYSTEM OPEN
17:30 01 Jan
Press ENT to
Select Functions
Press ENT to
Do part set A ?
Please Exit Now.
Time left > 0035
Part Set A
17:31 01 JAN
?
A B C
? ? ? 1
2
3
4
or or
LC D R e m o te
U n se ttin g Afte r a n Ala rm
If analarmhasoccurred whilst the alarmsystemisfull orpart set, the displaywill indicate
the detectioncircuitthatwastriggered whenyouunsetthe system. Once the cause of the
alarmhasbeenestablished the systemmust be reset, se e Re se tting a fte r a n a la rm o n
p a g e 1 0 .
1 . Enter the premises via the
prescribed entryroute and proceed
directly to the remote keypad. The
internal sounders generate an
interrupted tone. The display will
show the remaining entry time.
2 . Enter your 4 digit passcode before
the entry timer expires. The internal
sounderswill stopandthedisplaywill
show the circuit that caused the
alarm.
3 . Refer to Re se tting Afte r a n Ala rm
o n p a g e 1 0 .
w
If c irc uit te xt ha s b e e n p ro g ra m m e d the n the d isp la y o n the LC D a nd
Sta rb urst re m o te ke yp a d s w ill a lte rna te b e tw e e n the c irc uit num b e r a nd
the c irc uit te xt a t ste p (2 ).
9
Enter Your Code
Time Left > 0022
ALARM 03
17:31.02 01/01
? ? ? ?
1
2
LOUNGE DETECTOR
17:31.02 01/01
LC D R e m o te
NOTES
R e se ttin g Afte r a n Ala rm
Your alarm company will have programmed the system to be either User Reset,
Engineer Reset or Remote Reset, consult your alarm company if you are not sure.
U se r R e se t
If yoursystemhasbeenprogrammed asuserreset, alarmscanbe reset byanyuserthat
has a valid passcode.
From step (3) of Unsetting After an Alarm, proceed as follows:
1 . Enter your passcode and within 5
seconds press[ESC].
2 . The systemisnowreset and backinthe
open mode. After 5 seconds the
SYSTEMOPENmessage will disappear
and the displaywill showthe time, (date
and banner text, LCD only).
En g in e e r R e se t
If yoursystemisprogrammed asengineerreset, alarmscan onlybe reset byyouralarm
company.
From step (3) of Unsetting After an Alarm, proceed as follows:
1 . The displaywill alternate between the
circuit that caused the alarmand the
Call Engineer To Reset System
message. The internal sounderswill also
generate a beep every minute to
remind you that the system requires
resetting.
2 . To silence the beeps enter your
passcode.
3 . Contact your alarm company:
1 0
SYSTEM OPEN
17:30 01 Jan
ALARM 03
17:31.02 01/01
? ? ? ? 1
ESC
2
LC D R e m o te
CALL ENGINEER TO
RESET SYSTEM
ALARM 03
17:31.02 01/01
? ? ? ?
LC D R e m o te
1
2
R e m o te R e se t
If your system is programmed as remote reset, alarms can be reset by your alarm
company or via the exchange or unique passcodes.
From step (3) of Unsetting After an Alarm, proceed as follows:
1 . Thedisplaywill alternatebetweenthecircuit
that caused the alarm and the Call
Engineer To Reset Systemmessage. The
internal sounderswill also generate a beep
everyminute to remind youthat the system
requires resetting.
2 . Enter your passcode, this will silence the
beepsand the systemwill displaya unique
4 digit number. Contact your alarm
company or alarm receiving centre:
3 . You will be asked to report the
circumstances of the alarm. If the alarm
receivingcentredecidesyoudonotrequire
anengineer, a 4digitremoteresetcodewill
be given to you.
4 . After you have entered the code pressthe
[ENT] keyand the systemwill return to the
open condition.
1 1
Remote Reset
Quote > ????
Reply > ----
SYSTEM OPEN
15:30 01 JAN
ALARM 03
17:31.02 01/01
? ? ? ?
2
3
4
ENT
? ? ? ?
LC D R e m o te
CALL ENGINEER TO
RESET SYSTEM
1
Use r Me nu 1
In tro d u c tio n
Usermenu1isaccessed byentering yourpasscode followed by[ENT]. There are 12menu
options and access to these options will depend on your access level.
1 2
User menu 1
Select Option :-
Sounder. ON> 09
PRESS ESC to end
Walk Test
Press ESC to end
Remote Reset
Quote> 9472
Change pass code
New code > ----
Chime ccts are
Enabled
SYSTEM OPEN
13:30 01 JAN
Omit Circuits
Enter CCT No.>--
Silent Set ?
Enter Group > -
Please Exit Now.
Time left > 0010
Please Exit Now.
Time left > 0010
1
2
3
4
5
6
7
8
A
B
C
0
Bell Test
Walk Test
Remote Reset
Change Passcode
Enable Chime
Omit Circuits
Omit Shunt Group
Silent Set
Full Set
Part Set A,B,C
? ? ? ?
ENT
+
LC D R e m o te
Be ll Te st
This option allows you to periodically test the external sounders (bell and strobe) and
internalsounders. Whenselectedeachdevicewilloperateinsequencefornineseconds.
1 . Fromthe unset(open)mode enteryour
passcode and press [ENT] to select
user menu 1.
2 . Whilstusermenu1isselected. Press[1]
to select the bell test option.
3 . The internal sounder operates for 9
seconds, then the external sounder
operates for 9 seconds, then the
externalstrobeoperatesfor9seconds.
4 . Whenall three testsare completed, the
displayshowsusermenu1. Toreturnthe
systemtotheopenmodepress[ESC].
1 3
User menu 1
Select Option :-
SYSTEM OPEN
17:30 01 JAN
SYSTEM OPEN
17:30 01 JAN
Sounder.ON> 09
PRESS ESC to end
BELL...ON> 09
PRESS ESC to end
Strobe.. ON> 09
PRESS ESC to end
1
ESC
1
2
3
4
User menu 1
Select Option :-
? ? ? ?
ENT
+
LC D R e m o te
Wa lk Te st
Thisoptionallowsyouto testthefunctionof individual detectioncircuitswithoutcausingan
alarm. As each circuit is activated the circuit number and status are displayed and the
internalsoundersgeneratea twotoneChimesound. Oncethetesthasbeencompleted
the tested circuits can be reviewed in numerical order.
1 . From the unset (open) mode enter your
passcode and press [ENT] to select user
menu 1.
2 . Whilst usermenu 1 isselected. Press[2] to
select the walk test option.
3 . Activate detection circuits in turn by
opening doors with alarm contacts and
walking in front of movement detectors.
4 . When the test hasbeen completed, press
the [ESC] key. The display will now
automatically scroll through the circuits
that were tested in numerical order. The
current status of the circuit is also
displayed. The [ENT] key can be used to
scroll through the tested circuits more
quickly, if desired.
5 . Press [ESC] to leave the walk test option
and return to user menu 1. To return the
system to the open mode press[ESC].
R e m o te R e se t
This option allows the user to reset the systemafter an alarmbyusing a Remote Reset
code. The full procedure is explained in Re se tting Afte r a n Ala rm o n p a g e 1 0 .
1 4
User menu 1
Select Option :-
SYSTEM OPEN
17:30 01 JAN
SYSTEM OPEN
17:30 01 JAN
Walk Test
Press ESC to end
Office Window
CCT 14 Active
Office Door
CCT 12 Active
Tested CCTs were
Press ESC to end
2
ESC
ESC
ESC
1
2
3
4
5
Office Door
CCT 14 Healthy
Office Door
CCT 12 Healthy
User menu 1
Select Option :-
? ? ? ?
ENT
+
LC D R e m o te
C h a n g e Pa ssc o d e
Thisoptionallowsyouto change yourownpasscode. The masteruserscanalso add and
delete user passcodes, see Set-up Users on page 24.
1 . From the unset (open) mode enter your
passcode and press[ENT] to select user
menu 1.
2 . Whilstusermenu1isselected. Press[4] to
select the change passcode option.
3 . Enter your newpasscode then press the
[ENT] key. A rising tone indicates
acceptance and the system returns to
usermenu1. Alowtoneindicatesanerror
and youwill be prompted to re-enteryour
new code.
4 . To return the system to the open mode
press[ESC].
1 5
User menu 1
Select Option :-
SYSTEM OPEN
17:30 01 JAN
SYSTEM OPEN
17:30 01 JAN
Change pass code
New code > ----
Change pass code
New code > 1212
User menu 1
Select Option :-
ENT
4
ESC
1
2
3
4
? ? ? ?
ENT
+
LC D R e m o te
En a b le C h im e
Detection circuits that have been programmed as Chime will generate a two-tone
sound when triggered. This option allows you to select one of the four chime options:
1 D isa b le d Chime circuits are disabled.
2 En a b le d Chime circuits are enabled at all times.
3 En a b le d in P/Se t Chime circuits are enabled when the system is unset or part set.
4 En a b le d in U n se t Chime circuits are only enabled when the system is unset.
1 . From the unset (open) mode enter your
passcode and press[ENT] to select user
menu 1.
2 . Whilstusermenu1isselected. Press[5] to
select the enable chime option.
3 . Select the chime optionbypressing keys
[1] to [4] or by pressing [B] to alternate
between all 4 options.
4 . When the display shows the required
setting press the [ENT] keyto accept. A
rising multi-tone will be heard and the
system is returned to user menu 1.
5 . To return the system to the open mode
press[ESC].
1 6
User menu 1
Select Option :-
SYSTEM OPEN
17:30 01 JAN
SYSTEM OPEN
17:30 01 JAN
Chime ccts are
Disabled
Chime ccts are
Enabled
Chime ccts are
Enabled in P/Set
Chime ccts are
Enabled in Unset
User menu 1
Select Option :-
5
ESC
ENT
1
2
3
4
5
1 4
? ? ? ?
ENT
+
LC D R e m o te
Iso la te /R e -in sta te Sh u n t G ro u p
One or more circuits can be assigned to the shunt group, this is normally done by your
alarmcompanyalthoughthemasterusercanalsoconfigurethecircuitsthatareassigned
to the shunt group, se e Alte r Shunt G ro up o n p a g e 2 7 . Once a shunt group hasbeen
defined thisoptionallowsyouto isolate and re-instate the circuitsthatare assigned to the
shunt group.
Iso la tin g a Sh u n t G ro u p
1 . Fromthe unset(open)mode enteryour
passcode and press [ENT] to select
user menu 1.
2 . Whilst usermenu1isselected. Press[6]
to select the isolate/Re-instate shunt
group option.
3 . The system will automatically return to
the open mode and the display will
indicate that circuits are isolated.
R e -in sta tin g a Sh u n t G ro u p
1 . Fromthe CCTISOLATEDmode enter
your passcode and press [ENT] to
select user menu 1.
2 . Whilst usermenu1isselected. Press[6]
to select the isolate/Re-instate shunt
group option.
3 . The systemwill automaticallyreturn to
the open mode and the display will
indicate that the system is open.
1 7
User menu 1
Select Option :-
SYSTEM OPEN
17:30 01 JAN
CCTS ISOLATED
09:45 01 JAN
6
1
2
? ? ? ?
ENT
+
LC D R e m o te
User menu 1
Select Option :-
SYSTEM OPEN
17:30 01 JAN
CCTS ISOLATED
09:45 01 JUN
6
1
2
? ? ? ?
ENT
+
LC D R e m o te
O m it C irc u its
Occasionallyitmaybenecessarytoomitdetectioncircuitswhensettingorpartsettingthe
system. Thisallowsthe useraccessto the omitted area(s)whenthe systemissetorpartset.
It is also possible to omit 24hr or Auxiliary circuits so that access to these areas can be
obtained when the system is unset.
Onlydetection circuitsthat have been programmed by
your alarm company as Omit can be selected when
using this option.
1 . Fromthe unset (open) mode enter your passcode
and press[ENT] to select user menu 1.
2 . Whilstusermenu1isselected. Press[7] to selectthe
omit circuits option.
3 . Select the circuit you require to omit by either
entering the circuit numberorbyusing the [A] and
[C] keystoscrollupanddownthroughthecircuits.
4 . Whenthe required circuitnumberisdisplayed press
the [B] key to alternate between Armed and
Omitted. If a lowtone is heard when pressing the
[B] key the selected circuit cannot be omitted.
5 . When the displayshowsthe required setting for the
selected circuit, press the [ENT] key to accept. A
rising multi-tone will be heard and the display will
show the next available circuit.
6 . If required repeat from step (3) for other circuits,
When you have selected all the required circuits,
press the [ESC] key.
a ) If you have selected 24hrcircuits, the system
will automatically return to the unset mode
and the display will indicate that circuits are
isolated.
b ) If you have only selected night circuits, the
system will return to user menu 1. From user
menu 1 you must press[0] to full set, [A], [B]
or[C] for part set.
w
If yo u ha ve se le c te d a nig ht c irc uit to b e o m itte d , yo u m ust p e rfo rm a full o r
p a rt se t w hilst the use r m e nu is se le c te d . If yo u re turn to syste m o p e n a ll
se le c te d c irc uits w ill b e c a nc e lle d .
1 8
User menu 1
Select Option :-
User menu 1
Select Option :-
SYSTEM OPEN
17:30 01 JAN
Please Exit Now.
Time Left > 9999
Omit Circuits
Enter CCT No.>-
Office Detector
CCT 03 Armed
Office Detector
CCT 03 Omitted
Store Room PIR
CCT 04 Armed
CCTS ISOLATED
09:45 01 JAN
ENT
ESC
7
1
2
3
4
5
6
a
b
0 A 3 C OR /
B
0 A B C
? ? ? ?
ENT
+
LC D R e m o te
NOTES
Sile n t Se t
Thisoptionallowsyoutofull setorpartsetthesystemsilently, i.e. noexitsounder, acceptfor
set confirmation tone.
1 . Fromthe unset (open) mode enteryour
passcode and press [ENT] to select
user menu 1.
2 . Whilst usermenu 1 isselected. Press[8]
to select the silent set option.
3 . Press[0] to silent full set , [A], [B] or[C]
for silent part set.
Fu ll Se t a n d Pa rt Se t
This option offers an alternative method of full setting and part setting.
1 . Fromthe unset (open) mode enter your passcode and press [ENT] to select user
menu 1.
2 . Whilstusermenu1isselected. Press[0] to full setthe systemor[A], [B] or[C] to part
set the system.
1 9
User menu 1
Select Option :-
SYSTEM OPEN
17:30 01 JAN
Silent Set ?
Enter Group > -
Please Exit Now .
Time Left > 0025
SYSTEM SET
17:31 01 JAN
8
0 A B C
1
2
3
? ? ? ?
ENT
+
LC D R e m o te
Use r Me nu 2
In tro d u c tio n
User menu 2 is accessed by pressing [ENT] whilst user menu 1 is selected. There are 10
menu options and access to these options will depend on your access level.
2 0
User menu 2
Select Option :-
CCT 01 Healthy
Set Clock > ----
Set Date > ----
Setup users
User No. > --
Alter Chime ccts
Enter CCT No.>--
Alter Shunt grp
Enter CCT No.>--
Omit Circuits
Enter CCT No.>--
Configure Omits
for part set A
PASSCODE 01
09:30.05 01/01
CCT 01, (B=Edit)
LC D R e m o te
1
2
3
4
5
6
7
8
9
B
View Circuits
Set Clock
Set Date
Setup User Codes
Alter Chime Circuits
Alter Shunt Group
Configure Part Set
Log Printout
View Event Log
Circuit Text
? ? ? ?
ENT
+
ENT
Vie w C irc u its
Thisoptionallowsyouto ascertainthe statusof eachdetectioncircuit, The statusforeach
circuit may be as follows:
H e a lth y The normal status of a detection circuit, i.e. door closed or detector healthy.
Ac tive Thisisthealarmstatusofa detectioncircuit, i.e. dooropenordetectorinalarm.
Ta m p e r Thisisthe tamperopencircuitstatusof a detectioncircuit, i.e. alarmcable cut
or a cover removed from a detector.
Sh o rte d Thisisthe short circuit statusof a detection circuit, i.e. alarmcable shorted or
damaged.
1 . From the unset (open) mode enter your
passcode and press [ENT] twice to
select user menu 2.
2 . Whilstusermenu2isselected. Press[1] to
select the viewcircuitsoption.The display
will show the status of circuit 01.
3 . Select the circuit you require to view by
either entering the circuit number or by
pressing the [A] and [C] keysto scroll up
and down through the circuits.
4 . To return the system to the open mode
press[ESC] three times.
2 1
User menu 2
Select Option :-
SYSTEM OPEN
17:30 01 JAN
CCT 01 Healthy
CCT 01 Active
SYSTEM OPEN
17:31 01 JAN
LC D R e m o te
ESC ESC ESC
1
1
2
3
4
? ? ? ?
ENT
+
ENT
Se t C lo c k
Thisoptionallowsyoutoadjustthesystemclock. Theclockisusedforprovidingeventtimes
in the event log and is also displayed when the system is unset or full set.
1 . From the unset (open) mode enter your
passcode and press[ENT] twice to select
user menu 2.
2 . Whilst usermenu 2 isselected. Press[2] to
select the set clock option.
3 . Enter the newtime in a 24hr format, e.g.
1700 for 5:00 PM. When the displayshows
the correct time press[ENT] to accept.
4 . To return the system to the open mode
press[ESC] twice.
2 2
User menu 2
Select Option :-
User menu 2
Select Option :-
SYSTEM OPEN
17:30 01 JAN
Set Clock > ----
Set Clock > 1700
SYSTEM OPEN
17:00 01 JAN
LC D R e m o te
ENT
ESC ESC
2
1 7 0 0
1
2
3
4
? ? ? ?
ENT
+
ENT
Se t D a te
Thisoptionallowsyouto setthe systemdate. Itisdisplayed ina date / monthformatonall
LCD remote keypads.
1 . From the unset (open) mode enter your
passcode and press[ENT] twice to select
user menu 2.
2 . Whilst usermenu 2 isselected. Press[3] to
select the set date option.
3 . Enter the new date in a date/month
format, e.g. 1806forthe 18thJ une. When
the display shows the correct date press
[ENT] to accept.
4 . To return the system to the open mode
press[ESC] twice.
2 3
User menu 2
Select Option :-
User menu 2
Select Option :-
SYSTEM OPEN
17:30 01 JAN
Set Date > ----
Set Date > 1806
SYSTEM OPEN
17:31 18 JUN
ENT
ESC ESC
3
1 8 0 6
1
2
3
4
LC D R e m o te
? ? ? ?
ENT
+
ENT
Se tu p N e w U se rs
The TS590allowsup to 15usersto operate the alarmsystem, eachuserisassigned a user
type and a passcode. User 01 is the master user which has a default setting of 5678.
U se r Typ e s
The following user types are available:
1 - M a ste r Thisusertypecanfull set, partsetandunsetthesystem. Amasteruser
also has access to all user menus and options providing the alarm
company has programmed the master user for full access. If the
master user has been programmed for limited access the master
user cannot accessuser menu 2 option 6 (Alter shunt group) and 8
(Configure Part Sets).
2 - Sta n d a rd Thisusertype can full set, part set and unset the system. Astandard
user also has access to all the options in user menu 1.
3 - H o lid a y Thisusertypecanfullset, partsetandunsetthesystem. Aholidayuser
also hasaccessto all the optionsinusermenu1. However, Whenthe
system is next unset by a master user, the holiday passcode is
automatically deleted from the system.
4 - Se t O n ly Thisusertype operatesin the same wayasa standard user, except
that it only allows setting and part setting of the system.
5 - R e se t O n ly This user type allows unset alarms such as 24hr, fire, auxiliary to be
silenced and reset. The user type also has access to user menu 1
options 1 to 7.
6 - D u re ss Thisusertype operatesinthe same wayasa standard user, butwhen
thepasscodeisuseda silentPanic Alarmistransmittedtothealarm
receiving centre.
If e na b le d b y yo ur a la rm c o m p a ny a ll use rs c a n g e ne ra te a Dure ss
a la rm b y e nte ring the ir p a ssc o d e w ith the first tw o d ig its re ve rse d
(e . g . fo r a p a ssc o d e o f 2 5 8 0 e nte r 5 2 8 0 to g e ne ra te a Dure ss
a la rm ).
7 - PA C o d e Thisusertype doesnothave accessto anyusermenusnorcanitbe
used to set and unset the system. When thisuser code isentered a
Panic Alarm' is transmitted to the alarmreceiving centre and the
external sounder(s) and strobe light(s) are also activated.
8 - Sh u n t Thisusertype doesnothave accessto anyusermenusnorcanitbe
usedto setandunsetthesystem. Whenthisusercodeisentereditwill
isolate a predefined group of detection circuits. When the code is
re-entered it will reinstate the group.
This use r typ e is d isp la ye d a s Ac c e ss o n the sta rb urst re m o te
ke yp a d .
2 4
Se tu p N e w U se rs C o n t. )
1 . From the unset (open) mode enter your
passcode and press[ENT] twice to select
user menu 2.
2 . Whilst usermenu 2 isselected. Press[4] to
select the set-up new users option.
3 . Enter the user number (02 - 15) that you
require to set-up, then press [ENT].
4 . The display shows the current type
assigned forthe selected user, to change
the user type press [1] - [8]. When the
display showthe required user type press
[ENT] to accept.
5 . Enterthe 4digit passcode forthe selected
user, then press [ENT] to accept. Arising
multi-tone indicates the new passcode
was accepted. A low tone indicates that
the passcode entered is not available,
re-enter, using a different 4 digit code.
6 . The systemwill return to step 3, if required
repeat forotherusersorpress[ESC] three
times to return the system to the open
mode.
2 5
User menu 2
Select Option :-
Alter user type
Master
Change pass code
New code > ----
Change pass code
New code > 2580
SYSTEM OPEN
17:30 01 JAN
Setup users
User No. > --
Setup users
User No. > --
Alter user type
Not in use
SYSTEM OPEN
17:31 18 JAN
ESC ESC ESC
4
0 8 5 2
ENT
ENT
ENT
0 3
1
2
3
4
6
LC D R e m o te
? ? ? ?
ENT
+
ENT
1 8
5
Alte r C h im e C irc u its
This option allows you to select which detection circuits will cause a chime tone when
triggered. Once programmed, usersthat have accessto usermenu1canselect one of
the four chime options, se e Ena b le C him e o n p a g e 1 7 .
1 . From the unset (open) mode enter your
passcode and press[ENT] twice to select
user menu 2.
2 . Whilst usermenu 2 isselected. Press[5] to
select the alter chime circuits option.
3 . Select the required circuit by either
entering the circuit numberorbyusing the
[A] and [C] keys to scroll up and down
through the circuits.
4 . When the required circuit is displayed,
press[B] to alternate betweenSilentand
Chime. When the display shows the
required setting press [ENT] to accept. A
rising multi-tone will be heard and the next
available circuit is displayed.
5 . Repeat from step 3 for other circuits or
press [ESC] three times to return to the
open mode.
2 6
User menu 2
Select Option :-
Entrance Door
CCT 06 Chime
Loading Bay Door
CCT 07 Silent
SYSTEM OPEN
17:30 01 JAN
Alter Chime ccts
Enter CCT NO.>--
Entrance Door
CCT 06 Silent
SYSTEM OPEN
17:31 01 JAN
ENT
5
B
1
2
3
4
5
LC D R e m o te
? ? ? ?
ENT
+
ENT
ESC ESC ESC
0 A 6 C OR /
Alte r Sh u n t G ro u p
Thisoptionallowsyouto define whichdetectioncircuitsare allocated to the shunt group.
Once assigned to the shuntgroup all circuitswithinthe group canbe isolated byanyuser
thathasaccessto usermenu1option6(OmitShuntGroup). The shuntgroup canalso be
assigned to a user code (Shunt), this allowthe group to be omitted and re-instated by
entering a 4 digit passcode.
1 . From the unset (open) mode enter your
passcode and press[ENT] twice to select
user menu 2.
2 . Whilst usermenu 2 isselected. Press[6] to
select the alter shunt group option.
3 . Select the required circuit by either
entering the circuitnumberorbyusing the
[A] and [C] keys to scroll up and down
through the circuits.
4 . When the required circuit is displayed,
press [B] to alternate between Armed
and Omitted.
5 . When the display shows the required
setting press [ENT] to accept. A rising
multi-tone will be heard and the next
available circuit is displayed.
6 . Repeat from step 3 for other circuits or
press [ESC] three times to return to the
open mode.
2 7
User menu 2
Select Option :-
Accounts Office
CCT 09 Omited
Canteen D.Tec
CCT 10 Armed
SYSTEM OPEN
17:30 01 JAN
Alter Shunt Grp
Enter CCT NO.>--
Accounts Office
CCT 09 Armed
SYSTEM OPEN
17:31 01 JAN
ESC
ENT
ESC ESC
6
B
1
2
3
4
5
6
LC D R e m o te
? ? ? ?
ENT
+
ENT
0 A 9 C OR /
Prin t Syste m Lo g
Thesystemlogstores700events. If a printerisconnectedto youralarmsystemitispossible
to print a selected number of log events.
1 . From the unset (open) mode enter your
passcode and press[ENT] twice to select
user menu 2.
2 . Whilst usermenu 2 isselected. Press[7] to
select the print system log option.
3 . Enter the number of events to be printed
(001- 700). Press[ENT] tostarttheprintout.
To cancel printout repeat fromstep 2and
enter 000 for the number of events.
4 . To return the system to the open mode
press[ESC] twice.
2 8
User menu 2
Select Option :-
User menu 2
Select Option :-
SYSTEM OPEN
17:30 01 JAN
Print System Log
No. events> ---
Print System Log
No. events> 150
SYSTEM OPEN
17:31 01 JAN
ENT
7
1 5 0
1
2
3
4
LC D R e m o te
? ? ? ?
ENT
+
ENT
ESC ESC
Se t-u p Pa rt Se ts
TheTS590canbeconfiguredto haveupto threepartssetmodes(PartSetA, PartSetBand
PartSetC). Thisoptionallowsthemasterusertoconfigureeachpartsetmode. Withineach
partsetmode youmustdesignate whichcircuitswill remainarmed and whichcircuitswill
be omitted. Whenthe relevantpartsetmode isselected the systemonlyarmsthe circuits
that are designated as armed and isolates the circuits that are designated as omitted.
1 . Fromthe unset (open) mode enteryourpasscode and press[ENT] twice to select
user menu 2.
2 . Whilstusermenu2isselected. Press[8] to
select the set-up part sets option.
3 . Select the part set mode you require to
set-up by pressing [A], [B] or [C] then
[ENT].
4 . Select the required circuit by either
entering the circuit number or by using
the [A] and [C] keys to scroll up and
down through the circuits.
5 . When the required circuit is displayed,
press [B] to alternate between Armed
and Omitted. An armed circuit will
remain armed when the systempart set,
an omitted circuit will be isolated when
the system is part set.
6 . When the display shows the required
setting press [ENT] to accept. A rising
multi-tone will be heard and the next
available circuit is displayed.
7 . Repeat from step 3 for other circuits or
press [ESC] three times to return to the
open mode.
2 9
User menu 2
Select Option :-
Sales Office
CCT 05 Omitted
Canteen Door
CCT 06 Armed
SYSTEM OPEN
17:30 01 JAN
Configure Omits
for part set A
Accounts Office
CCT 01 Armed
SYSTEM OPEN
17:31 01 JAN
ENT
8
B
1
2
3
4
5
7
LC D R e m o te
? ? ? ?
ENT
+
ENT
A or B or C
ENT
A C /
Sales Office
CCT 05 Armed
ESC ESC ESC
6
Vie w Lo g
The TS590 store up to 700 events in the log. This option allows you to view each event.
1 . From the unset (open) mode enter your
passcode and press[ENT] twice to select
user menu 2.
2 . Whilst usermenu 2 isselected. Press[9] to
select the view log option.
3 . Thedisplaywillshowthemostrecentevent,
see log event codes. To navigate through
the log, use the [A] and [C] keys to scroll
backwards and forwards.
4 . The [B] key can be used to display
additional information, including circuit
information, for the select event.
5 . To return the system to the open mode
press[ESC] three times.
3 0
User menu 2
Select Option :-
SYSTEM OPEN
07:30 01 JAN
PASSCODE 01
09:30.59 28/04
ALARM 05
06:30.59 28/04
Office Door
06:30.59 28/04
SYSTEM OPEN
17:31 01 JAN
9
B
1
2
3
4
5
LC D R e m o te
? ? ? ?
ENT
+
ENT
ESC ESC ESC
A C /
Lo g Eve n t C o d e s
LC D D e sc rip tio n
AC OFF Mains power removed.
AC RESTORED Mains power restored
ACTION ALARM Alarmactivated whensystemispart-set.
ALARM 01-14 Full alarm from circuit (01-14).
AUX/BELL TAMPER Auxiliary tamper activated.
AUXILIARY 01-14 Auxiliary circuit activated.
BATTERY FAULT Battery fault (voltage below 10.5V).
BELL TESTED External bell and strobes tested.
CALL BACK No. 01-03 Modem making a call back to remote PC.
CCT OMITTED Circuits omitted by the user at time of Setting.
CCTS ISOLATED 24Hr group omitted during the unset condition.
CCTS TESTED 01-14 The number of circuits tested during Walk Test.
CODE TAMPER Code tamper from keypad 01-04
COMMS ACTIVE Plug-on digicom active.
COMMS FAILED Plug-on digicom failed to communicate.
COMMS SUCCESSFUL Plug-on digicom communicated successfully.
DATE CHANGED System Date changed.
DEFAULT CODE User passcode (01) reset to 5678 by the engineer.
DELAY ALARM 01-14 Delayed alarm during a part-set condition.
DURESS 01-15 Duress alarm from user passcode (01-15).
ENTRY 01-14
Entry timer started by circuit (01-14).
ENTRY ALARM 01-14
Entry timed-out alarm from circuit (01-14).
FACTORY RESTART
System Factory Restarted.
FIRE ALARM 01-14
Fire alarm circuit activated.
FIRST KNOCK 01-14
The first activation of a Double Knock circuit.
FUSE BLOWN 01
Control Panel 12V Auxiliary Fuse blown.
KEY POINT 01-14
Key point operation from circuit (01-14).
LINE FAULT
Telephone line fault detected.
LINE RESTORED
Telephone line fault restored.
MODEM LOCK-OUT
Modem failed to communicate.
NO EVENT
No log event.
OMITS REMOVED
Previously omitted circuits reinstated.
ON-SITE RESTART
System On-Site restart.
3 1
LC D D e sc rip tio n
PA ALARM 01-14 Panic Alarm circuit activated.
PA CODE 00-15 Panic Alarm passcode entered (00 = Keypad PA).
PANEL LID TAMPER Control panel lid removed.
PART SET A/B/C SystemPart-Set using one of the A, B, orC buttons.
PASSCODE 00-15 User passcode entered. (00-15).
REM REMOVED 01-04 Remote Keypad removed from system.
REM SERVICE CALL Remote service call via Lineloadsoftware and PC.
REM TAMPER 01-04 Remote Keypad cover removed.
REMOTE ADDED 01-04 Remote Keypad added to the system.
REMOTE RESET System reset by Remote Reset passcode.
SERVICE CALL END Remote service call finished.
SERVICE REQUIRED Service required
SET FAIL System failed to Set.
SYSTEM OPEN System fully unset.
SYSTEM RE-ARMED System re-armed all healthy circuits.
SYSTEM SET System fully set.
TAMPER 00 Short circuit on ID loop.
TAMPER 01-14 Tamper alarm from circuit.
TEST CCTS OFF All circuits taken off Test
TEST FAIL 01-14 Circuit failed during Test.
TIME CHANGED System time changed
WALK TEST System Walk Test selected.
3 2
En a b le R e m o te Se rvic e
If youralarmsystemhasbeenfitted witha modem, the alarmcompanycandial into the
systemand remotelyread and write data fromthe control panel. Foradded security, your
alarmsystemcan be programmed so that a master user has to authorise the writing of
data to the control panel.
1 . Fromthe unset(open)mode enteryour
passcode and press [ENT] twice to
select user menu 2.
2 . Whilstusermenu2isselected. Press[0]
to select the enable remote service
option. If a low tone is heard your
system has either been configured so
thatremoteservicingisalwaysenabled
or your system does not have a
modem fitted.
3 . The display will showthe current status
of remote servicing (Enabled or
Disabled). Press [B] to alternate
between the two options.
4 . When the display shows the required
setting press [ENT] to accept. A rising
multi-tone will be heard and the system
will return to user menu 2.
5 . To returnthe systemto the openmode
press[ESC] twice.
3 3
User menu 2
Select Option :-
SYSTEM OPEN
09:30 28/04
Remote Call Back
Enabled
Remote Call Back
Disabled
User menu 2
Select option:-
SYSTEM OPEN
09:31 28/04
0
B
1
2
3
4
5
LC D R e m o te
? ? ? ?
ENT
+
ENT
ENT
ESC ESC
In itia te Se rvic e C a ll
If youralarmsystemhasbeenfitted witha modemitispossible fora masteruserto initiate
an upload sequence to a remote site (normally the alarm company). Once the
communication link is established, the remote site can read and write data from the
control panel.
1 . From the unset (open) mode enter your
passcode and press[ENT] twice to select
user menu 2.
2 . Whilst usermenu2isselected. Press[A] to
select the Initiate remote service call
option. If a lowtone is heard your system
does not have a modem fitted.
3 . Press[1] - [3] toselectcall-backtelephone
number 1 -3.
4 . When the display shows the required
telephone number press [ENT] to initiate
the call-back sequence.
5 . The systemwill automatically return to the
open mode.
3 4
User menu 2
Select Option :-
SYSTEM OPEN
17:30 01 JAN
Call Number 1
0181 12345678
SYSTEM OPEN
17:31 01 JAN
A
1
2
3
4
LC D R e m o te
? ? ? ?
ENT
+
ENT
ENT
1 = Call No.1
2 = Call No.2
3 = Call No.3
C irc u it Te xt
Eachdetectioncircuitcanhaveupto16charactersoftextassignedtoit. Thisoptionallows
you to program / edit the circuit text.
1 . Fromthe unset (open) mode enteryourpasscode and press[ENT] twice to select
user menu 2.
2 . Whilst user menu 2 is selected. Press[B] to select the circuit text option.
3 . Select the required circuit by either entering the circuit number or by using the [A]
and [C] keys to scroll up and down through the circuits.
4 . Whenthedisplayshowstherequiredcircuitpress[B] toeditthetext, thetextcursorwill
appear at the bottom left hand position on the display.
5 . Use the keysto edit the text. Whenthe displayshowsthe required text press[ENT] to
accept.
6 . Repeat fromstep 3 forothercircuitsorpress[ESC] three time to return to the open
mode.
3 5
User menu 2
Select Option :-
SYSTEM OPEN
17:30 01 JAN
Office Detector
CCT 01, (B=Edit)
Office Detector
^CT 01, (B=Edit)
B
1
2
3
5
LC D R e m o te
? ? ? ?
ENT
+
ENT
ENT
A = Next circuit
B = Edit text
C = Previouscircuit
Cursor
Use keysto edit text
SYSTEM OPEN
17:31 01 JAN
Office Door
CCT 01, (B=Edit)
ESC ESC ESC
6
7 8
0
9
1 2 3
4 5 6
A B C
ENT ESC
A E I
O U 0 (zero)
Move cursorleft Change case Move cursorright
Accept text Space Abandon text editing
Up the alphabet Change cursor Down the alphabet
Te xt Ed itin g Ke ys
4
C u rso r Typ e s
Thisisthe normal text cursor. Use the text editing
keyasshown above.
Thisisthe number cursor. Use the numbered
keys0 - 9 to enternumeric data.
^
|
Fa ult Find ing
D isp la y M e ssa g e s
D isp la ys D e sc rip tio n
There isno mainspowerto the control panel and the alarmsystemisnow
running on itsstandbybattery. The systemwill also generate a chime tone
every minute to warn you that the fault exists, to silence the chime tones
simplyenteryourpasscode. If the mainspowerisnotrestored youmaynot
be able to set the alarmsystem. If the fault persiststhe standbybatterywill
eventually run flat. Contact your alarm company for further advice.
Afull alarmhasoccurred froma detectioncircuit(circuit05). Thismessage
isnormallydisplayafterunsetting the alarmsystem. Before the systemcan
besetagainthealarmsystemmustbereset, se e Re se tting Afte r a n Ala rm
o n p a g e 1 0 .
Anauxiliaryalarmhasoccurredfroma detectioncircuit(circuit06). Thetype
ofalarmissilentandwillactivatetheappropriateoutputs. Toresetthealarm
simply enter your passcode followed by [ESC].
Thecontrolpanelauxiliaryorbelltampercircuitshavebeenactivated. Ifthe
faultisnotclearedyouwillnotbeabletosetthealarmsystem. Tosilencethe
alarmsimplyenteryourpasscode. Contactyouralarmcompanyforfurther
advice.
Thealarmsystemstandbybatteryhasdevelopeda fault, normallybecause
the systemmainspowerisnot present. If the fault isnot cleared youwill not
be able to set the alarm system. To silence the alarm simply enter your
passcode. Contact your alarm company for further advice.
One or more circuits have been isolated from the system. For full details
refer to Iso la te / Re -Insta te Shunt G ro up o n p a g e 1 8 .
Apasscode hasbeenincorrectlyentered more thanfourtimesata remote
keypad (keypad 02). To silence the alarm enter a correct passcode. To
reset the alarm simply enter your passcode follows by [ESC].
Adelayed full alarmhasoccurred froma detectioncircuit (circuit 05). This
message is normally display after unsetting the alarm system. Before the
systemcan be set again the alarmsystemmust be reset, se e Re se tting
Afte r a n Ala rm o n p a g e 1 0 .
An entrytime out alarmhasoccurred froma detection circuit (circuit 01).
Thisisnormallycausedwhentheentryprocedureisstartedandthesystemis
not unset before the timerexpires. Before the systemcanbe set againthe
alarm system must be reset, se e Re se tting Afte r a n Ala rm o n p a g e 1 0 .
3 6
DELAY ALARM 05
17:30 01 Jan
DELAY ALARM 05
17:30 01 Jan
AC OFF
17:30 01 Jan
AUX/BEL TAMPER
17:30 01 Jan
BATTERY FAULT
17:30 01 Jan
CCTS ISOLATED
17:30 01 Jan
ALARM 05
17:30 01 Jan
AUXILIARY 06
17:30 01 Jan
CODE TAMPER 02
17:30 01 Jan
DELAY ALARM 05
17:30 01 Jan
CODE TAMPER 02
17:30 01 Jan
ENTRY ALARM 01
17:30 01 Jan
D isp la y M e ssa g e s C o n t. )
D isp la ys D e sc rip tio n
Afire alarmhasoccurred froma detection circuit (circuit 07). The internal
sounderwill generate a distinctive fire alarmtone and the external sounder
is pulsed on and off. To silence the alarmsimplyenter your passcode. To
reset the alarm simply enter your passcode again followed by [ESC].
The auxiliarysupplyused forpowering detectiondeviceshasblownitsfuse.
Youwillnotbeabletosetthealarmsystemuntilthefaultisrectified. Contact
your alarm company for further advice.
A panic alarm (PA) has occurred from a detection circuit (circuit 08). To
silence the alarm simply enter your passcode. Reset the panic alarm
device if required (normallywitha key). To resetthe alarmsimplyenteryour
passcode again followed by [ESC].
Apanic alarm(PA) passcode hasbeen entered at a remote keypad bya
user(user15). To silence the alarmsimplyenteryourpasscode. To resetthe
alarm simply enter your passcode again followed by [ESC].
The lid of the control panel hasbeenremoved. If the faultisnotcleared you
will not be able to set the alarmsystem. To silence the alarmsimplyenter
your passcode. Contact your alarm company for further advice.
Youralarmsystemisfitted witha remote signalling device whichisreporting
a telephone line fault. The system will also generate a chime tone every
minute to warn you that the fault exists, to silence the chime tones simply
enteryourpasscode. If the fault isnot cleared you maynot be able to set
the alarm system. If the fault persists, contact your alarm company for
further advice.
The lid of a remote keypad hasbeenremoved (remote 01). If the faultisnot
cleared you will not be able to set the alarmsystem. To silence the alarm
simply enter your passcode. Contact your alarm company for further
advice.
The system has failed to set. This normally caused by a circuit being left
open at the time of setting. Check that all circuits are healthy before
attempting to set the alarm system.
Another user is operating the alarmsystemfromanother remote keypad.
Whentheyhavefinishedallremotekeypadswillreverttonormaloperation.
Atamperalarmhasoccurred froma detectioncircuit(circuit02). Normally
caused byremoving the coverfroma movement sensorora breakinthe
circuitcabling. Tosilencethealarmsimplyenteryourpasscode. Ifthefaultis
notclearedyouwill notbeabletosetthealarmsystem. Contactyouralarm
company for further advice.
3 7
FIRE ALARM 07
17:30 01 Jan
FUSE BLOWN 01
17:30 01 Jan
PA ALARM 08
17:30 01 Jan
PA CODE 15
17:30 01 Jan
PANEL LID TAMPER
17:30 01 Jan
PHONE LINE FAULT
17:30 01 Jan
REM TAMPER 01
17:30 01 Jan
SET FAIL
17:30 01 Jan
SYSTEM IS BUSY
PLEASE WAIT.
TAMPER 02
17:30 01 Jan
Syste m Re c o rd s
U se r R e c o rd
U se r Typ e N a m e
01 Master
02
03
04
05
06
07
08
09
10
11
12
13
14
15
D e te c tio n C irc u it R e c o rd
C irc u it Lo c a tio n O m it C h im e P. Se t A P. Se t B P. Se t C
01
02
03
04
05
06
07
08
3 8
D e te c tio n C irc u it R e c o rd C o n t. )
C irc u it Lo c a tio n O m it C h im e P. Se t A P. Se t B P. Se t C
09
10
11
12
13
14
Se rvic e R e c o rd
D a te En g in e e r Ac tio n
3 9
Syste m D e ta ils
Entry Time Exit Time
Bell Delay Bell Duration
Full Set By Part Set A by
Part Set B by Part Set C by
Reset by Allowsetwithlinefault
Set with mains off Remote signalling
Downloading User Authorised
Remote 1 Function Indicator
Remote 2 Function Indicator
Remote 3 Function Indicator
Remote 4 Function Indicator
In sta lle r In fo rm a tio n
Installation Engineer:
Alarm Company:
Address:
Telephone No.:
AlarmReceivingCentre:
Telephone No.:
Date Installed:
4 9 6 8 5 9 Issu e 1
4 0