Prepared Checked Approved LINE NO. : 155-D-8"-PF Design Case: base case ROUTING : SPS-"D" Well #P1/P2/P3/P4 TO 100-D-8" (Existing Yakin WB) SERVICE : Gross Oil DESIGN CRITERIA 1. Fluid velocity less than errosional velocity v < Ve 2. Allowable Pressure Drop DP / 100 ft psi/100 ft Calculation input data Gas Rate Q G MMSCFD 0.30 (*) HC Liquid Rate Q O BPD 3000.00 (*) Aqueous Rate Q W BPD 9000.00 (*) Pressure P psig 130 (*) Temperature T F 130 (*) Gas Molecular Weight MW 18.14 (*) Gas Compressibility Z 0.9788 (*) Gas density r G lb/ft 3 0.4744 (*) HC Liquid Density r O lb/ft 3 53.4054 (*) Aqueous Density r W lb/ft 3 63.6174 (*) Average density r M lb/ft 3 15.954 (*) Gas Weight Rate W G lb/hr 600 (*) Liquid Weight Rate W L lb/hr 171384 (*) Gas Viscosity m G cp 0.0125 (*) Liquid Viscosity m Lhc cp 4.0400 (*) Aqueous Viscosity m Laq. cp 0.4600 (*) Liquid Surface Tension s L dyne/cm 10.7100 (*) CALCULATION Liquid Specific gravity sg L 0.979 Erosional Velocity Ve fps 25.036 Baker Map Factor -1 L m 2.488 Baker Map Factor -2 f i 5.450 Nominal Pipe Size NPS Sch Iinside Diamneter Option 1 6 80 5.761 (*) Option 2 8 80 7.625 (*) Option 3 10 80 9.564 (*) Fluid Velocity v fps Option 1 16.54 Option 2 9.44 Option 3 6.00 Liquid weight flow rate per cross section area W m lb/hr.ft 2 Option 1 Option 2 Option 3 Gas weight flow rate per cross section area G lb/hr.ft 2 Option 1 Option 2 Option 3 Baker Map Y Axis Option 1 Option 2 Option 3 Baker Map X Axis Option 1 Option 2 Option 3 Baker Flow Regime Option 1 Option 2 Option 3 Pressure Drop DP / 100 ft psi/100 ft Option 1 0.05 Option 2 0.01 Option 3 0.00 SELECTED NPS inch 8 (*) Notes: (*) Item to be specified Description Gas/liquid two-phase Line Sizing Calculation Rev Date 1893 BUBBLE BUBBLE 1203 1333 947258 3316 540735 343704 3872.8353 3872.8353 BUBBLE 761 484 3872.8353 Hysim No.02