Академический Документы
Профессиональный Документы
Культура Документы
GUIDELINES FOR
DRAWING NUMBERING
8-52-0005 Rev. 3
Page 1 of 8
15.09.05
15.09.98
PM
RK
BRS
01.02.94
PM
BRS
RB
13.05.91
AKA
BRS
RB
AKV
Checked
by
Standards
Committee
Convenor
Standards
Bureau
Chairman
Rev.
No
Date
Purpose
PM
Prepared
by
VJN
AKV
Approved by
Format No. 8-00-0001-F1 Rev. 0
GUIDELINES FOR
MR TITLES
8-52-0007Rev. 3
Page 2 of 8
Abbreviations:
Mr. P. Mahajan
Mr. H.C. Jain
Mr. A.K. Ghosh
Mr. T.G. Mohan
Mr. K.V. Chandramouli
Mr. S. K. Sood
GUIDELINES FOR
MR TITLES
8-52-0007Rev. 3
Page 3 of 8
CONTENTS
1.
PURPOSE
2.
SCOPE
3.
REFERENCES
4.
DETAILS
5.
GUIDELINES FOR
MR TITLES
8-52-0007Rev. 3
Page 4 of 8
1.0
PURPOSE
1.1
The purpose of this document is to define titles for MRs (Material Requisitions) and PRs
(Purchase Requisitions). For convenience however, only MR is used for reference.
This is needed to establish a definite co-relation with Vendor List so that interpreting the title is
not required by someone who is not a specialist in Instrumentation. Strict adherence to the
titles will be necessary.
1.2
This design guide further lists the MR numbers for the titles.
2.0
SCOPE
2.1
This document supplements "Guidelines for MR Numbering" 8-1651-0003, and should be read
in conjunction with it.
2.2
2.3
b)
c)
3.0
REFERENCES
3.1
Guidelines
8-76-0004
4.
DETAILS
4.1
10
11
12
13
14
15
E
This details of these are given in that guideline.
In this guideline, the titles and corresponding numbers (digits 11, 12, 13, 14) are given in
detail.
4.2
a)
In some MRs, there is requirement of choices for the types of items included in the
MR. These choices have an implication in vendor selection or method of floating.
These are defined in brackets.
Example:
COPPER TUBES (COATED, BARE)
Format No. 8-00-0001-F1 Rev. 0
GUIDELINES FOR
MR TITLES
b)
8-52-0007Rev. 3
Page 5 of 8
In the case of choice, user shall list all the required choices. But no unwanted choice
is to be included.
Example:
COPPER TUBE (COATED)
COPPER TUBE (BARE)
COPPER TUBE (COATED, BARE)
only coated
only bare
some coated and some bare are required
Title
Positive Displacement
Meters
Variable Area Flowmeters (
)
1020
2020
1030
1040
1050
1060
1080
2030
2040
2050
2060
2080
1090
2090
Turbine Flowmeters
Averaging Pitot Tubes
Magnetic Flowmeters
Mass Flowmeters - Coriolis
Terminal Automation
System
Turnkey Instrumentation
1100
2100
Pressure Gauges
1110
1120
1130
1140
2110
2120
2130
2140
1150
2150
1160
1170
2160
2170
Draft Gauges
Pressure Switches
SCADA System
Turbine Metering SystemLiquid
OR
Turbine Metering SystemLiquid and Meter Prover
Turbine Metering System Gas
Electro-Hydraulic Valves
Gas Chromatograph Natural Gas
Remarks
Liquid Service
Generic for `Rotameter'.
Choices ( ) :
Indicators
Transmitters
Indicators and Transmitters
Liquid service, not gas
GUIDELINES FOR
MR TITLES
Identification
Number
Indigenous
Imported
1180
2180
1190
2190
Title
8-52-0007Rev. 3
Page 6 of 8
Remarks
1200
2200
1210
2210
1220
1230
2220
2230
1240
2240
1250
2250
1260
1270
2260
2270
1300
2300
Displacer Level
Instruments
Level Switches (Displacer,
Float)
1310
2310
1320
2320
1330
2330
Control Valves
(If availability is
ascertained and inclusion
Format No. 8-00-0001-F1 Rev. 0
Transmitters
Choices ( ) :
Displacer
Float
Displacer, Float
Can include transmitters
and switches.
Choices ( ):
Capacitance
Conductivity
Capacitance, Conductivity
Can include local devices
and receiving systems upto
TFM with only Servo items
GUIDELINES FOR
MR TITLES
Identification
Number
Indigenous
Imported
Title
in this MR is more
convenient, butterfly
valves also can be
considered here)
1340
2340
Self Actuated
Pressure Control Valve
1350
2350
2360
1360
8-52-0007Rev. 3
Page 7 of 8
Remarks
considered.
Imported items (2330):
Standard globe
(single/double port,
cage, cryogenic) valves.
Valves with Bellows seal.
High Pressure drop Globe.
OR
Pressure Relief Valves
with Rupture Discs
1370
1380
2370
2380
1390
1400
2390
2400
Solenoid Valves
Temperature Gauges
(Bimetallic, Filled System)
1410
2410
Temperature Elements,
Thermowells
GUIDELINES FOR
MR TITLES
Identification
Number
Indigenous
Imported
1430
1440
1450
2430
2440
2450
1460
2460
1500
1520
1530
1540
1560
2500
2520
2530
2540
2560
1600
2600
1610
2610
1620
1630
2620
2630
1640
1650
2640
2650
1660
2660
1670
2670
1680
1700
2680
700
Title
OR
Thermowells
Skin Thermocouples
Desuperheaters and
Pressure
Reducing Stations
OR
Desuperheaters
OR
Pressure Reducing
Stations
On-Off Valves
[This includes shutdown
valves.
Do not use the title
"Shutdown
Valves"]
Safety Valves - Boiler
Service
Distributed Control System
Training Simulator
Receiver Instruments
Closed Circuit TV
Pilot Operated Safety
Valves
Oxygen Analysers Zirconia
pH Analysers
OR
Conductivity Analyser
OR
pH, Conductivity Analysers
Moisture Analysers
Gas Chromatographs
with Shelter
OR
Gas Chromatographs
LEL Detection System
Fire and Gas Detection
System
Analyser Systems
with Shelter
OR
Analyser Systems
Density Meters - Vibrating
Tube
Stack Analyser System
Copper Tubes (Coated,
8-52-0007Rev. 3
Page 8 of 8
Remarks
Test thermowells
Select suitable title.
Pressure Reducing Station
includes Steam Pressure
Let-Down valves
Indigenous (1450):
Ball Valves for On-Off
service.
Imported (2450):
Ball, Butterfly, Other
Rotary On-off valves.
Steam service requiring
ASME Sec I / IBR
certification
Humidity in air
Select title as required
Choices ( ):
Copyright EIL All rights reserved
GUIDELINES FOR
MR TITLES
Identification
Number
Indigenous
Imported
Title
Bare)
1710
1720
2710
2720
S.S. Tubes
Tube Fittings
1730
2730
1740
2740
1750
2750
1760
2760
1810
2810
1820
2820
Thermocouple Extension
Cables
Loading System
5.
5.1
None.
8-52-0007Rev. 3
Page 9 of 8
Remarks
Coated
Bare
Coated, Bare
Can include SS and Brass
fittings
GUIDELINES FOR
MR TITLES
8-52-0007Rev. 3
Page 10 of 8
APPENDIX-1
Digit 12
0
Details
General job drawings other than control room, control
panel, Instrument location drawings.
Graphic Schemes
Interlock Schemes
User Assignable
Future
Future