Вы находитесь на странице: 1из 4

www.norgren.

com/info/en3-222
For further information
3-222
HERION 24010 SERIES
3/2 Direct solenoid actuated poppet valves
G1/4, 1/4 NPT or Connection hole pattern NAMUR
TV-approval based on IEC 61
508, DIN V 19 251 Approvals: DIN
EN 161/3394 DVGW, group Rm
and EN 13611 Valves for safety
systems to SIL 4 or AK 7
Solenoid valve also suitable for
low power consumption in non
hazardous areas without barrier
Solenoid: Category II2GD, Type of
Protection EEx ia IIC T5/T6, IP66,
T95C, Suitable for zones 1, 2
(gases) and 21, 22 (dusts)
Working from 0 bar up
High operational reliability even
after long periods of inoperation
Suitable for control and
instrument-quality air
Also suitable for open-air
installation with appropriate
solenoid variant
NAMUR FLANGE:
With integrated exhaust air
recirculation
TECHNICAL DATA
Medium:
For neutral, not flammable,
gaseous and liquid fluids*
*With contaminated fluids, upstream installation
of a dirt trap is recommended.
Flow direction:
Optional
Mounting position:
Any, but preferably with solenoid
vertical
Connection:
G1/4, 1/4 NPT
Operating pressure:
0 ... 10 bar
Ambient temperature:
-25C* ... +60C
*Please consult our technical service for use
below +2C. If installed in the open protect all
connections against the penetration of moisture!
MATERIALS
Housing: Brass, hard-anodized
aluminium
Seals: NBR (Perbunan)
Internal parts: Stainless steel,
brass
Solenoid housing: Aluminium,
anodized
G1/4 0 ... 10 0,340 Brass NBR 1 2401088.2003
1/4 NPT 0 ... 10 0,340 Brass NBR 1 2401087.2003
G1/4 0 ... 10 0,340 St. st. NBR 1 2401086.2003
1/4 NPT 0 ... 10 0,340 St. st. NBR 1 2401012.2003
G1/4 NAMUR 0 ... 10 0,340 Aluminium
*2)
NBR 2 2401091.2003
1/4 NPT NAMUR 0 ... 10 0,340 Aluminium
*2)
NBR 2 2401090.2003
G1/4 NAMUR
*3)
0 ... 10 0,340 Aluminium
*2)
NBR 3 2401009.2003
Symbol Port size kv-value
(Cv(US) kv x 1,2)
Seal Drawing
no.
MODELS
a
a
b
b
2
1 3
12
2
3 1
3
2
Switching function: Pressure connection 1, 2 or 3
*1)
With gaseous and liquid fluids up to 40 mm
2
/s.
*2)
Hard-anodized.
*3)
P port in flange interface.
Note: At an ambient temperature of -20C, higher leakage values may be experienced for short periods.
Operating
*1)
pressure (bar)
Material
housing
3-223
Time
Time
Time
Time
On Off
On Off
On Off
On Off
Switching delay
Solenoid parameters for use in intrinsically safe circuits
22 ... 28 V 110 mA min 40 mA 5 V 0,3 - 5 II2G EEx ia IIC T6 -40 ... +55 2003
II2G EEx ia IIC T5 -40 ... +70
II2D IP66 T95C -40 ... +70
Solenoid parameters for use in non hazardous locations
22 ... 26,4 V 75 mA min 40 mA 1,8 W at 24V 0,3 - 2 s IP 66 -40 ... +80 2003
0612790 (NAMUR single connection plate) 0540593 C/S2, 1/4 NPT
0612791 (NAMUR-rip use in combination with 0612790, Alu) M/S2, G1/4
Silencer Yoke Flange plate
ACCESSORIES
Operating sequence
28 V
22 V
0 V
25
V
20
15
10
5
0
120
100
80
75
60
40
20
0
mA
28 V
22 V
0 V
C
u
r
r
e
n
t

p
r
o
c
e
s
s
C
h
a
r
g
i
n
g

v
o
l
t
a
g
e

p
r
o
c
e
s
s
S
u
p
p
l
y
V
a
l
v
e
,

o
p
e
r
a
t
i
n
g

s
t
a
t
u
s
Current supply units:
Intrinsically safe power supply units can be
choosen in a list of compatibility in
www.norgren.com
When selecting an intrinsically safe power supply, it is
important to observe the maximum permissible values
acc. to the EC-Type-Examination Certificate
PTB 04 ATEX 2010
U0 28 V, L0 110 mA, P0 1,5 W
The effective internal capacities Ci; and inductivities
Li of the solenoid are negligibly low.
Function of solenoid drive
To switch the direct operated valve, a certain energy is
required. This energy is stored in a condenser.
The charging voltage is 22 V. The higher the supply
voltage, the shorter the charging time. As soon as the
charging voltage has been reached, the valve switches.
The small current now flowing through the coil is
sufficient to hold the valve in the open position.
At least 40 mA are required for this.
Solenoid
codes
Temperature
ambient/fluid C
Categorie,
type of protection
Switch-on
voltage (V)
max. allowed
current Ii
Holding
current
Holding
voltage
Pick-up delay typical
(s)
Solenoid
codes
Temperature
ambient/fluid C
Categorie,
type of protection
Switch-on
voltage (V)
max. current
(limited)
Holding
current
Holding
voltage
Pick-up delay typical
(s)
3-224
HERION 24010 SERIES 3/2 Direct solenoid actuated poppet valves
G1/4, 1/4 NPT or Connection hole pattern NAMUR
3
1
2
70,5
1
2
.
2
3
5
.
7
5
1
9
8
1
0
8
5.5
27
55
1
2
1
2
30
1 2
1
2
1


1
5
,
5
1
9
G

1
/
4
G
1
/4


1
9
,
5
16
17
50
3
7
,
5
3 3
2 2
22,5
32 6,5
6,5
5
2
1
2
2
4
4
,
5
1
3
,
5
5
,
5
1
5
19
G 1/4
4
22
7,5
122
29
M
5
2
6
,
5
70,5
50
1
0
4
1
1
3
1 2
3
1


1
5
,
5
G
1
/4


1
9
,
5
16
17
50
3
7
,
5
3 3
2 2
22,5
32 6,5
6,5
5
2
1
2
2
4
1
3
,
5
5
,
5
1
5
19
G 1/4
4
22
7,5
122
29
1,5
M
5

1
0
M
6
2
6
,
5
70,5
50
1
0
4
1
1
3
1 2
3
4
,
5
3
DIMENSIONS
1 M20 x 1,5
For port size see general information
3 deep
2
3
3-225
M5
32
2
2
4
3
3
5
4
2
5
1
,
5
8
,
5


1
0
,
5
60
60

1
3
3
4
Circuit diagrams Filter cartridge (for threads G1/4 and 1/4 NPT)
Type: 0681173
NAMUR hole pattern
2 Port 2 (A)
Coding stud threaded
M5 (10 deep)
Port 3 (R)
3
4
5
Thread pitch diameter
max. 11,85 mm