AC-ERGO MOTOR CONTROL CARD





FEATURES

Direct replacement for BFT AC slider control cards (ERGO, LEM,
COMPAT)
Open and close limit input for normally closed contacts (N/C)
Controls a single phase 220V AC motor with closing, common, opening
windings and a start capacitor
Selectable breaking (use with ERGO)
Pedestrian opening input
Infra red beam safety input
Button or receiver control input
Courtesy lamp output for relay contact and programmable time
Gate status indication output for LED display inside the house
Built in buzzer for programming indication and pedestrian opening
Programmable motor run time for protection on limit switch failure.
Selectable and programmable auto-closing time
Selectable PIRAC mode
Selectable SECURITY mode
Selectable CONDOMINIUM/LOOP mode
Auxiliary 24V AC output supply for external devices

E.T.
T a k e C

ontrol Of Your World!


-2-

TECHNICAL SPECIFICATIONS


POWER SUPPLY VOLTAGE 220V AC
MOTOR VOLTAGE 220V AC
MOTOR POWER 900W Max
AUXILIARY OUTPUT VOLTAGE 24V AC
AUXILIARY OUTPUT CURRENT 230 mA


CONTROL CARD INSTALLATION PROCEDURE

REFER TO WIRING DIAGRAM PAGE 4 & 5

CONNECTIONS
PLEASE NOTE:
PL3 Term. 5: MOTOR (C) COMMON IS 220VAC NEUTRAL
PL1 Term. 8: CONTROL (C) COMMON IS +12V DC

LIMIT SWITCH


Normally closed (N/C) switches are connected:
OPEN LIMIT to PLG 1 Term 13 (LIM O)
CLOSED LIMIT to PLG 1 Term 14 (LIM C)
COMMON to PLG 1 Term 8 (C)




MOTOR:

The motor winding is connected:
Closing to PLG 3 Term 6 (CL - MOTOR) CLOSING.
Opening to PLG 3 Term 4 (OP - MOTOR) OPENING
Common to PLG 3 Term 5 (C-MOTOR) COMMON



STARTER
CAPACITOR

Starter capacitor to PLG 2 Term 19 (CAP) & Term 20
(CAP)




GATE
OPENING

PUSH BUTTON/
RECEIVER/
FREE EXIT
LOOP
Push button, receiver, free exit loop normally open
contacts (N/O) to PLG 1 Term 9 (BT) & Term 8 (C) (+).
A receiver [ET-RX1L/24V] can be used
If a magnetic free exit loop detector [ET-MD99] is used,
card must be set to condominium mode.





-3-

PEDESTRIAN
OPENING
Pedestrian key switch or intercom button with normally
open contacts (N/O) is connected to PLG 1 Term 10 (PD)
& Term 8 (C).
This facility opens the gate partially for pedestrians.


INFRA RED
BEAM
Beams normally closed contacts (N/C) are connected to
PLG 1 Term 11 (BM) & Term 8 (C).
This prevents the gate closing on an object in its path.
When closing, breaking the beam will make the gate stop
and open.
Please Note:
If no Beams are installed make sure there is a wire link
between Term 11 (BM) & Term 8 (C) PLH 1


GATE STATUS
LED
INDICATION
An LED can be fitted inside the house for status
display.
LED cathode (-) to PLG 1 Term 15 (S) & anode (+) to
Term 8 (C)


LED INDICATOR
ON GATE OPEN
OFF GATE CLOSED
FLASHING SLOW GATE MOVING
FLASHING FAST GATE STOPPED



COURTESY
LIGHT :
RELAY
SWITCHED
(OPTIONAL ET-
RELAY
MODULE)
Connect a 12V DC relay coil across PLG 2 Term 22 (R)
& PLG 1 Term 8 (C) .
A light can be switched in series with the relay normally
open contacts (N/O). The relay contact rating must match
the light power chosen.
The courtesy light will switch on automatically, timed
from when the gate is opened and for a period after the
gate is closed.


EXTERNAL
WARNING
BUZZER
A 12V DC Buzzer can be connected across:
Buzzer (-) to PLG 1 Term 12 (Z) & Buzzer (+) to Term
8 (C).
The buzzer will sound briefly before the gate begins to
move.
Gate closed : buzzer off
Gate moving : buzzer beeps on & off
Gate fully open : buzzer off







-6-

CONTROL CARD PROGRAMMING

MOTOR MUST BE SETUP ONTO GATE
ALL MOTOR WIRING AND LIMITS MUST BE SETUP
SWITCH ALL CONTROL CARD (DIP) SWITCHES 1-6 OFF


POWER ON BUZZER BEEPS ONCE
PLACE (JP-PROG) JUMPER ON TWO PINS BUZZER BEEPS TWICE


AUTOCLOSE &
RUN TIME
SET (DIP) SWITCH 1 ON
Press & release (PROG BUTTON)- Gate will close onto close
limit or if already on close limit, will then run open to open
limit and stop and beep for Auto-close time. Buzzer beeps per
second.
At Auto-close time, press & release (PROG BUT) Buzzer
stops then gate runs closed and stops onto closed limit, the
buzzer beeps twice.
Switch (Dip) 1 OFF


PEDESTRIAN SET (DIP) SWITCH 2 ON
Press & release (PROG-BUTTON) Gate will OPEN or if the
gate is not on CLOSED LIMIT, it will close & stop on
CLOSED LIMIT then OPEN.
Press & release (PROG-BUT) at required opening gate will
stop and beep per second for Auto-close time.
When auto-close time reached, press & release (PROG-BUT)
gate will close onto closed limit, buzzer will beep twice.
SWITCH (DIP) 2 OFF.


LIGHT ON TIME SET (DIP) SWITCH 3 ON
Press & release (PROG-BUT) Buzzer beeps per second.
When required time is reached, press & release (PROG-BUT):
buzzer will stop, then beep twice.
SWITCH (DIP) 3 OFF.

AUTO BREAK
MODE
(ERGO)
SET (DIP) SWITCH 6 ON
This mode will make the motor break / stop instantly the
moment the closed limit has been activated. To be used with the
ERGO motor if the motor gearbox is jamming.



REMOVE (JP JUMPER) - BUZZER WILL GIVE ONE
LONG BEEP
SET (DIP) SWITCHES TO REQUIRED SETTINGS

-7-

CONTROL CARD SETUP

DIPSWITCH SETTINGS
1 ON AUTOCLOSE ON
2 ON LOOP/CONDOMINIUM MODE
3 ON PIRAC MODE
4 ON SECURITY MODE
5 ON FLASH MODE
6 ON BREAK ON (OPEN & CLOSE LIMIT)

1. AUTOCLOSE (DIP 1 ON)
This is the time the gate will stay open before auto-closing.
NB! USE ONLY WITH INFRA-RED SAFETY BEAMS.

2. LOOP/CONDOMINIUM/FREE EXIT (DIP 2 ON)
- This mode is used for multiple user dwellings and its function is to prevent
another user operating the gate while one user is in the process of driving
through the gate.
- The gate can only be triggered to open by remote, button or free exit loop and
not to stop or close.

3. PIRAC MODE BEAM ACTIVATION (DIP 3 ON)
- This mode works with an INFRA RED BEAM.
- While the gate is opening and a vehicle drives through, it breaks the beam.
The beam is restored as the vehicle has passed, causing the gate to imediately
stop and close. This bypasses the open limit and auto-close time.

4. SECURITY MODE BUTTON / REMOTE ACTIVATION (DIP 4
ON)
- This mode works with activation of the button input (BT), connected to a
button or remote control receiver.
- When the remote is activated while the gate is opening, the gate will stop and
close.
- This does not work in condominium mode i.e dipswitch 2 OFF.

5. FLASH MODE (DIP 5 ON)
- This mode causes the light / relay to flash three times before the gate closes.
- The light / relay will work otherwise as per programmed time.

6. BREAK MODE (DIP 6 ON)
- This mode causes the gate motor to break quickly while opening or closing on
its limit and prevents jamming at the gate stoppers.



NB!
Auto-close should only be used with an infra-red beam for safety so the
gate does not auto-close onto an object unsupervised.




-8-
FAULT FINDING
220V AC SLIDING GATE MOTOR
SYMPTOM CAUSE ACTION
Limit switch wired to
incorrect contacts
Wire correct contact (N/C)
settings see page 2.
Limit switch faulty. Replace limit switch.
Motor moves, and then
stops when button is
pressed.
Beam (BM) input open Short beam input (N/C)
Motor too hot, thermal cut-
out switch
Wait for motor to cool.

Motor faulty. Replace motor.
Motor does not turn when
button is pressed, but card
relays are operating and
there is voltage at motor
terminals.
Motor capacitor faulty. Replace capacitor.
Pedestrian or button input
permanently pressed.
Check pedestrian and button
switch.
Gate opens a short distance,
and then stops.
Induced voltage on
pedestrian or button long
line input.
Wire up a relay interface
and use contacts across
pedestrian or button input.
Gate opens but does not
auto close.
Auto close not selected. Set auto-close.(DIP 1 ON)
Motor hums with gate in
closed or open position but
does not move the gate
Gearbox jammed because
limit bracket not set
correctly
Set limit bracket so that gate
stops with a gap between
stoppers. ERGO set
breaking on (DIP 6 ON)
Auto-close time too long or
short.
Auto close not programmed
correctly.
Re-program auto-close
Gate will not respond to
button, while opening or
will stop and open while
closing.
Card set to condominium
mode.
Set condo. (DIP 2 OFF)
In condominium mode
while gate is closing, will
not stop and open after
button is pressed or beam
broken but closes and then
ignores the close limit
Motor capacitor faulty. Replace capacitor
Gate auto opens instead of
auto closing.
Motor wired incorrectly. Swap motor forward and
reverse winding and also
swap the corresponding
limit switches.
Main fuse blown. Replace with 5A fuse.
No 220VAC supply Check supply, wiring, fuse
Motor control card does not
respond to button. Power
LED OFF. Card faulty Contact supplier
Card locked up. Switch power OFF, wait
then switch ON.
Replace with 5A fuse.
Interference on long wire to
button
Wire a relay interface.
Connect the contacts to the
control card inputs and the
button to the coil
Short on button.

Remove and test at card
button input.
Motor control card does not
respond to button. Power
LED ON.
Card faulty Contact supplier