p r o d u c t f i n d e r Electric power generation and distribution is our business. We are a strong global company employing over 2,500 people across 27 locations in 15 countries worldwide. We support you with innovative solutions, competen- ce, quality, flexibility and continuity. As a member of the international NEWAGE AVK SEG Group, SEG Kempen develops, manufactures and sells high-quality switchboards, protection and control systems across three business segments. No matter whether standardised products or developments speci- fied by the customer are required - the solutions and services of the 350 people working at SEG rank among the top world-wide. The performance and service provided by the busin- ess segment Power Protection is based on more than 30 years of experience in low and medium voltage technology which has led to numerous international references and technical leadership in the field of spe- cial niche products. Development and testing of all our electronic devices comply, of course, with the relevant international standards and regulations such as IEC 60255. The manufacture of our products is subject to severe quality checks. This is also proven by the fact that we are certified according to ISO 9001. SYSTEM LINE - The digital all-roun- ders for all your medium-/high-vol- tage protection and control applications; from simple feeder and line pro- tection right down to transformer and busbar differen- tial protection in a reliable and consumer-friendly man- ner. The HIGH TECH LINE embodies top- quality protection in a compact, modular and 19"- compatible structure. Modern digital technology and easy handling leave hardly anything to be desired. The PROFESSIO- NAL LINE also com- prises digital protec- tion devices which fulfil all medium voltage technology standards, and which are designed for professionals who prefer to avoid door installation. You will quickly find out that these compact devices with DIN fixtures offer complete protection for medium and low-voltage applications. The WI LINE proves its benefits every day even under the toughest conditi- ons. There are already more than 38,000 of these current-transfor- mer-fed current protection relays in operation. The basis for this products success is its the customer-ori- ented design. Despite our large product range, if you still cannot find the right solution for your application in this bro- chure, together we will develop a solution to meet your requirements. CONTENTS THE POWER PEOPLE S EG P r o d u c t f in d e r 2 T h e P o w e r P e o p le WE INVEST ALL OUR ENERGY IN YOU Sophisticated product lines It is your choice THE POWER PEOPLE For you we invest Page 3 all our energy SYSTEM LINE The digital allrounders Page 4 - 5 Competence in: Feeder protection, Line, Transformer and Bus-bar Differential protection Page 6 - 7 Combined protection and control devices Page 8 - 9 HIGH TECH LINE Safe, precise, well-proven Page 10 - 11 Standard protection devices Page 12 - 13 Product choice Page 14 - 15 Connection examples Page 16 - 17 Technical datas and housing technology Page 18 - 19 PROFESSIONAL LINE The DIN rail trendsetter in medium voltage application Page 20 - 21 Product choice Page 22 - 23 Connection examples Page 24 - 25 WI LINE Tripping without auxiliary voltage Page 26 - 27 Compact and reliable Page 28 - 29 COMMUNICATION Communication is everything Page 30 - 33 OUR SERVICE We are at your service - 35 locations Page 34 - 36 on five continents Off to the new cell! With the optio- nally available parameter setting and evaluation soft- ware SL-SOFT you can copy complete parameter sets and single line diagrams from a PC to the CSP or vice versa. This way you simply load new single line dia- grams with the relevant interlocking logic into your SYSTEM LINE unit. For customer-specific requirements, individual functions can be generated by an internal programmable logic function called SL-LOGIC. Measuring, Evaluation, Diag- nosis: SYSTEM LINE devices record electrical values such as current, voltage, power, etc. But they also offer you numerous statistical and counting functions. For how many operating hours have your switchboards been running? How many switching cycles do your switching devices have? Energy metering, mean and maximum values? The answer is only a few clicks away. And after a fault event? Every- thing will be recorded by your SYSTEM LINE. You also have enough time to analyse a fault, even if it is only a matter of milliseconds. And if you want to know what events preceded the fault, the fault recorder will provide the answer. If that is not enough for you, you can simply carry out another analysis of the fault records via PC and copy this as a file. You can apply the same principle to take current flows over into your MS Office application or to zoom them into rele- vant time ranges. All this is made possible by the Data Recorder, a powerful software tool which pro- vides you, visually and graphically, with valuable information and contributes to reducing costs within your company. Standardised communication is a further highlight of SEGs SYSTEM LINE. Regard- less of whether you use process visualisation, via sta- tion SCADA systems, or building automation or ener- gy management systems, its no problem! You can skillfully link your medium-voltage switchboard to other systems via IEC870-5-103, PROFIBUS DP or MODBUS RTU using a standardised interface. This combined protection and control system integrates and helps to save costs because you do not require any expensive individual solutions. In addition, due to their great flexibility, the devices can be integrated step-by-step into existing or planned electrical energy distribution systems. Any further benefits required? Control and operating comfort of the SYSTEM LINE are unbeatable. If, for example, you have to change the parameters of some panels of your switchboard, SEG technology will offer you all the advantages our digital era can offer. It is up to you whether you wish to set the parameters of the respective panels locally or adjust the parameters of other panels via the ope- rating unit of one panel. Or you can link the opera- ting unit CMP to your notebook via a serial cable and carry out changes by means of the keyboard. The internal bus allows central evaluation of up to 16 devices. SYSTEM LINE MORE THAN PROTECTION S y s t e m L in e From where do you want to control? Its up to you whether you choose local control via the separate operating unit CMP, or remote control via a digital input or via SCADA System. SEG SYSTEM LINE will control almost all commonly available medium-voltage switchgears. Of course, the devices take into account the panel and system inter-locking functions. All operating or fault messages are given a time stamp with date and time. You may rest assured - nothing will happen without you knowing about it. Protection? - All inclusive! The feeder protection already includes 18 protective functions. All you need to do is to activate them. Even with the line and transformer differential protection all back-up protec- tion functions are already on board. Compact, universal, flexible. The compactly designed protection and control system fits into the smallest low-voltage niches and, thanks to its flexible field configurations, can be installed in all common switchboards irrespective of the manufacturer. But flexibility also means: ! a wide range power supply and universal in- and outputs, ! the current transformer inputs are designed for both 1 A or 5 A, ! you switch over between four different protective parameter sets. 4 T h e P o w e r P e o p le Protection, Control, Supervision - Are you looking for a complete solution for switchboards up to 132 kV instead of numerous individual units? The SYSTEM LINE devices are variable protection and control systems which offer you feeder, line, transformer and bus-bar protection. All these functions can be adjusted with ease and comfort. Standardised Communication Measuring Evaluation Diagnosis Protection Control Supervision Compact Universal Flexible S y s t e m L in e 6 T h e P o w e r P e o p le COMPETENCE IN: FEEDER PROTECTION, LINE, TRANSFORMER AND BUS-BAR DIFFERENTIAL PROTECTION given to just one or both or none of the circuit brea- kers. Also the transformer protection is able to con- trol up to 5 switching devices including power out- puts or two circuit breakers. Busbar protection At long last, an affordable bus-bar protection for me- dium-voltage range applications. And this is what Supply? Coupling? Transformer feeder? ... ... the CSP-F will manage all relevant protection and control tasks. The CSP-F has not only stood the test as a flexible standard solution in new switchboards, but is also highly suited for retrofitting old switchbo- ards. All inclusive - everything without extra charge, without expensive additional modules. With comfort and menu-guidance you can activate new device and protection functions with the tip of your finger - also later on in the switchboard. Line protection Do you require more than fast, selective line differen- tial protection? In addition to complete line protec- tion the CSP-L offers measuring and control functions as well as integrated backup protection. Since com- munication between the devices occurs via fibre optic conductors, data transmission is not only especially fast, but also extremely safe. Transformer protection With this high performance management system, two winding transformers can be protected and ope- rated completely. In order to cover and satisfy different trip philoso- phies, SEG has designed the CSP2-T in such a way, that it provides various trip characteristics relating to trip commands, and therefore commands can be characterises this High End Protection: fast, selective and safe against over-functionality. Stabilisation against c.t. saturation prevents faulty tripping. Up to 18 feeders are always in view on the display of the operating unit. And, of course, the positions of the individual circuit breakers, including their detailed measured current values are also shown on the dis- play of the operating unit CMP. CSP-F Feeder protection CSP-L Line protection CSP-T Transformer protection CSP-B Bus-bar diff. protection S y s t e m L in e COMBINED PROTECTION AND CONTROL DEVICES ANSI Protection functions Phase current Number of elements Phase current (directional) Number of elements Earth fault Number of elements Earth fault (directional) Number of elements Negative sequence (current) Number of elements Overload protection with thermal replica Voltage Number of elements Residual voltage Number of elements Voltage transformer supervision (fuse failure) Frequency Number of elements Power Number of elements Differential protection Auto reclosing (AR) Overexcitation Lock out function Control circuit supervision (CCS) Circuit breaker failure protection (CBF) Programmable protection logic Parameter switch Backward interlocking 50/51 Disturbance recorder (Optionally with extended storage range) 50/51/67 50N/51N 67N 46 49 27/59 59N 81 32 F/R 87 79 86 74 TC 50 BF O O O ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! Cable/Line 3 3 3 Bus-bar Bus-bar 2/2 2/2 4 4 ! ! 2 2 2/2 2/2 ! ! 2 2 2 2 2 2 2 3 3 CSP-F3 CSP-F5 CSP-L CSP-B 24 Measuring functions Phase currents Earth current Negative sequence current Differential currents Stabilizing currents Phase-to-phase voltages Phase-to-neutral voltages Frequency Power Power factor Energy counter Statistic measuring functions Currents Voltages Frequency Power CB operation counter Sum of short circuit currents Control functions Local/remote control (key switch) Number of controllable switching devices Number of recognizable switching devices Number of signal relays Number of configurable inputs Supervision functions Fault-/Differential position Programmable field interlocking Communication Profibus DP (option: fibre optic/RS485) IEC60870-5-103 (option: fibre optic/RS385) ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! O O O O O O ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! 5 3 6-18 5 10 16 12 7 6-18 11 6 5 5 5 6 16 CSP-F5 CSP-L CSP-B CSP-T Line 3 2 2/2 2 ! ! 8 T h e P o w e r P e o p le ! O= Option ! = Standard * in preparation O= Option ! = Standard * in preparation CSP-F3 ! ! 12 ! ! * ! 3 Base unit Operating units Feeder ! ! ! ! ! * * * ! ! * * ! O AR Fast trip ! ! ! Modbus RTU (option: fibre optic/RS485) O O O O CSP-T Transfor. Switch on to fault protection (SOTF) ! ! ! Restricted earth fault (REF) Temperature measurement 64 2 2 2 2 2/2 2 4 Transformer ! ! ! ! * ! ! ! ! ! ! ! O * * ! ! ! ! ! ! ! ! ! ! ! ! ! ! 5 6 ! O O Our eye for detail is also apparent in the plug connector especially developed for this design. It has 15 current/voltage inputs with screw terminals for connection to C.T.s and P.T.s (V.T.s). Its current inputs are designed for 100 x In/1s with automatic short-circuit mechanisms for the protection of the current transformers. 27 control inputs and outputs with connections for flat-pin plugs serve for fast and safe switchboard wiring. HIGH TECH LINE SAFE, PRECISE, WELL-PROVEN! H ig h T e c h L in e Arrangements as required. No matter whether you wish to protect grids, genera- tors, transformers or engines, the SEG relays with their modular structure and thousand-fold applications will stand up to any task. And it does not matter whether you wish to use individual or combination relays. Numerous additional func- tions have already been integrated into these relays and additionally offers you, among other func- tions, fault analysis and flexible adaptation to chan- ging operating conditions. The integrated communica- tion interface provides the linkage to the higher-level SCADA System. The additional SEG software makes parameter setting of the relays and fault analysis much easier. The HIGH TECH LINE has meanwhile progressed to the third generation with a high degree of perfection for applications such as time overcurrent protection, mains decoupling and motor protection. Furthermore it also offers further useful functions such as: ! display of date and time, ! two parameter sets, ! disturbance recorder, ! fault value memory, ! free configuration of the output relays (matrix), ! CB failure protection, ! display of primary values, ! triggering of the disturbance recorder by a digital input and ! Modbus RTU protocol. Complex protection functions are the special features of these de- vices for low, medium and high-voltage applications. This well-proven, con- tinuously developing line covers everything from basic over-current time pro- tection via machine protection right down to high-quality differential pro- tection. The intuitive operation of the HIGH TECH LINE relays deserves five stars for comfort. Thanks to its functional design, five keys, LEDs and alpha-numerical displays, it offers you a lot of flexibility in a minimum space. The simple operating surface combines functionality with comfort, with the integra- ted four-digit display serving as a clear text display for measured, fault and adjustment values. The LEDs guide you intuitively through the adjustment process or signal the actual status of the relay. The SEG micro-processor technology and the highly integrated electronics, which guarantee top precision and reliability, will be as effi- cient as your speed of acquiring operating and parame- ter setting skills. Sophisticated solutions are, for exam- ple, offered by the double functions of the SELECT/RESET button. It allows you to call up all measured and adjustment values one after the other and to acknowledge fault signals. This is possible even when the housing lid is closed or sealed. Fast fault detection. If a protective function is triggered, the display level changes to the trigger level. Here the measured values at the moment of triggering can be seen, which makes fault diagnosis simpler. The compact housing techno- logy is the result of the 19"-compatible rack- mounting feature consistently used for rack installati- on. But we also offer you separate housings for flush mounting. Compact und functional. Just as the HIGH TECH LINE functions are so numerous, so is the design of this series compact. You get precision in a minimum of space. All units are designed for modu- lar housing structures, based on 19" systems. Each relay is of plug-type design and therefore suited for front installation or mounting on a mounting plate. The HIGH TECH LINE with its extensive protection func- tions, numerous additional functions, the intuitive operation and the compact housing design guaran- tees High Tech Protection everywhere where power is generated, converted or distributed. Complex protection functions Compact housing technology Intuitive operation Manifold additional functions 1 0 T h e P o w e r P e o p le Protection functions and features Combinations Phase currents and earth current (directional or undirectional) Phase current, earth current, CB failure and AR (undirectional) Phase current, earth current and thermal replica (undirectional) Voltage and frequency Voltage and negative sequence Mains decoupling (U/ f/ vector) Mains decoupling (U/ f/ df/dt) Motor protection (various functions) Line features Housing technology 19"/flush mounting DIN rail mounting Panel mounting Display (measuring values and parameters) Indication of primary measuring values Interface Setting via buttons Setting via potentiometer Setting via DIP switches Fault memory Disturbance recorder, clock, 2 parameter sets Number of output relays Password protection ANSI MR IR X PROFESSIONAL LINE HIGH TECH LINE 50/51/67/50N/51N/67N 50/51/50N/51N/BF/79 50/51/50N/51N/49 27/59/81 27/59/47 27/59/81/78 27/59/81 37/46/48/49/50/51 I* IK IT* N3* N3* M* ! O ! ! 1 ! ! ! ! 1 5 ! ! O ! 1 or 2 UF UA RN N* RW RN* N* M ! only RN RW RI O only RN RW RI ! ! 2 with software STANDARD PROTECTION RELAYS H ig h T e c h L in e P r o f e s s io n a l L in e Parameter software HTL/PLSoft4 O O Protection functions and features Individual functions Phase current Phase current (directional) Earth current Earth current (directional) Circuit breaker failure protection Overcurrent voltage dependent Negative sequence (current) Voltage Residual voltage DC voltage Phase balance (voltage) Frequency Vector surge Power Differential protection Rotor earth fault (DC) Auto reclosing Lock out function Field failure (Impedance) Exciter failure (DC) Trip circuit supervision Phase sequence ANSI MR IR X PROFESSIONAL LINE HIGH TECH LINE 50/51 50/51/67 50N/51N 67N BF 51V 46 27/59 59N 27DC/39DC 47 81 78 32 87 64 79 86 40 37/40/64/76 74 TC 47 I* I* I* I* I* I* S U* U* U* F G P D* R K L Q R A U* I I U U D* I* RI I* I* S U* U* U* A F G P D* R E U* 1 2 T h e P o w e r P e o p le * Various types with this code ! = Standard O = Option 1 with HIGH TECH LINE devices type MR*3 only H ig h T e c h L in e Machine protection Diff Motor Diverse M R I 3 - I M R I 3 - I R M R I 3 - I R E M R I 3 - I R X M R I 3 - I R E R M R I 3 - I R X R M R I 3 - I R S R M R I 3 - I E M R I 3 - I X M R I 3 - I E R M R I 3 - I X R M R I 3 - I S R M R I 3 - E M R I 3 - X M R I 3 - E R M R I 3 - X R M R I 3 - S R M R I 3 - I T M R I 3 - I T E M R I 3 - I T E R M R I 3 - I H E M R I K 3 - I M R I K 3 - I E M R I 1 - I U M R I 1 - I N M R N 3 - 1 M R N 3 - 2 M R U 3 - 1 M R U 3 - 2 M R F 3 M R P 2 - 1 I U M R P 2 - 3 I U M R P 2 - R 1 I U M R P 2 - R 3 I U M R R 1 M R S 1 M R Q 1 M R D 1 - T M R D 1 - G M R M 3 - 2 - I M R M 3 - 2 - I E M R K 1 M R A 1 M R L 1 M R T 1 H T L - C U 2 3 0 Current transformer inputs 3 3 4 4 4 4 4 4 4 4 4 4 1 1 1 1 1 3 4 4 4 3 4 3 3 1 3 1 3 3 1 6(9) 6 3 4 Voltage transformer inputs 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1 1 3 1 3 3 Binary inputs 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 5 5 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 7 7 10 1 4 Output relays 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 3 4 4 4 4 4 4 2 4 Watchdog relay 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Protection functions Time overcurrent protection [50/51] ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! T r ip
c ir c u it
s u p e r v is io n T r ip -
a n d
a u x ilia r y
r e la y s T e s t
b lo c k C a p a c it o r
s t o r a g e Inrush stabilisation (2nd harmonic) ! Directional time overcurrent protection [67] ! ! ! ! ! ! Earth fault protection Standard [50N/51N] ! ! ! ! ! ! ! ! ! ! ! Sensitive EF isolated/compensated ! ! ! ! ! ! Resistance earthed / solidly earthed [50N/51N] ! ! ! Earth fault directional feature [67N] ! ! ! ! ! ! ! ! ! ! Thermal replica [49] ! ! ! ! ! Circuit breaker failure protection [50BF] ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! Voltage protection [27/59] ! ! ! ! Residual voltage [59N] ! ! Phase balance [47] ! Frequency protection [81O/U] ! ! ! Frequency gradient [81] ! ! Vector surge [78] ! Active power direction [32/37] ! ! ! ! Rotor earth fault- [64N], Exciter current protection [40/76], diode failure ! Negative sequence protection [46] ! ! ! Field failure protection [40] ! Locked rotor [51], incomplete start [48], max. number of starts [66], undercur- rent [37] ! ! Differential protection [87T / 87G] ! ! Special- and additional functions Auto reclosing ! ! ! Reset / Blocking ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! !/- Voltage dependent function ! ! ! ! ! ! ! ! ! Time + Date ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! Parameter sets 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 1 2 2 2 2 2 1 1 1 1 1 1 1 4 4 2 2 1 Fault recorder (none volatile) ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! Disturbance recorder ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! Output relay matrix ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! Communication RS485 RS485 Open Data protocol ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! Modbus RTU protocol O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O != Standard O= Option 1 4 T h e P o w e r P e o p le IT IS YOUR CHOICE M R I K 3 - I C E M R I K 3 - I C X M R I K 3 - I C E R M R I K 3 - I C X R M R I 3 - I C E M R I 3 - I C X M R I 3 - I C E R M R I 3 - I C X R 4 4 4 4 4 4 4 4 1 1 1 1 7 7 7 7 7 7 7 7 4 4 4 4 4 4 4 4 1 1 1 1 1 1 1 1 ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! 2 2 2 2 2 2 2 2 ! ! ! ! ! ! ! ! Time overcurrent protection ! Control and supervision of a circuit breaker (remote or local) M R I 1 - I E 4 2 4 1 ! ! ! ! 1 ! ! ! O ! Apparent power protection [37] M R P 2 - S 3 I U 3 3 2 4 1 ! ! ! ! ! ! 1 O Mains decoupl. H ig h T e c h L in e 1 6 T h e P o w e r P e o p le Phase voltage V-connection Phase voltage LV-direct connection Phase voltage HV/MV VT connection connection types for residual voltage measuring Phase current measuring (2-CTs) Earth current measuring with ring core transformer Combined phase- and earth current measuring Holmgreen - connection Phase current measuring CONNECTION EXAMPLES Connections of High Tech Line relays TECHNICAL DATAS AND HOUSING TECHNOLOGY H ig h T e c h L in e Data and setting ranges of the High Tech Line Common data Current transformer inputs Voltage transformer inputs Binary inputs Output- and Watchdog relay Voltage supply Power consumption Protective system front of housing Setting ranges Time overcurrent protection Earth fault protection standard Earth fault protection sensitive Voltage protection functions Frequency protection functions Frequency gradient Vector surge = 2 - 22 df = 0.2 - 10 Hz, dt = 2 - 64 cycles f = 0.6 - 1.4 x fn, tf = tfmin - 120 s U<, U<<, U>, U>>, U0>, U2> = 0.02 - 2 x Un, tU = 0.04 - 50 s IE> = 0.1 - 20% In, tIE> = 0.04 - 260 s resp. a = 0.05 - 10; IE>> = 0.01 - 15% In, tIE>> = 0.04 - 10 s IE> = 0.01 - 2 x In, tIE> = 0.04 - 260 s resp. a = 0.05 - 10; IE>> = 0.01 - 15 x In, tIE>> = 0.04 - 10 s I> = 0.2 - 4 x In, tI> = 0.03 - 260 s resp. a = 0.05 - 10; I>> = 0.5 - 40 x In, tI>> = 0.03 - 10 s IP54 max. 5 W 16-360 V DC / 16-270 V AC 250 V AC /2500 VA /8 A; 24 V DC to 60 V DC and 100 V to 230 V AC/DC Un = 100 V, 230 V, 400 V Pv < 1 VA In = 1 A Pv=0.2 VA / In = 5 A Pv=0.1 VA Ohmic L/R = 70 ms L/R = 40 ms 300 V DC 250 V DC 110 V DC 60 V DC 48 V DC 24 V DC 0.3 A 0.4 A 0.5 A 0.7 A 2.6 A 6 A 0.2 A 0.3 A 0.4 A 0.5 A 1.85 A 4.2 A 0.18 A 0.15 A 0.2 A 0.3 A 1.1 A 2.5 A Breaking capacity Making capacity 1 8 T h e P o w e r P e o p le The adjustment ranges listed in the table apply for protection relays in general. For details please refer to the relevant product documentation. 250 V AC 8 A Peak current 64 A / 0.005 s 16 A / 0.02 s Short time current Nominal current 8 A / 60 s Mounting plate set-up A-housing 19 subunit rack for door installation A-housing 19 subunit rack for panel mounting A-housing (also available with 42TE) Flush mounting D-housing HTL-6M12 HTL-3F42 HTL-3F84 HTL-6M48 All dimensions in mm Easy adjustment. DIP switches and potentiometers enable you to adjust the protective functions and tripping values quickly and safely. If you prefer to use a PC or a Notebook for this pur- pose, we offer you - as an option - an interface adap- ter plus the appropriate software. Active protection against changes in the settings is ensured by front covers that can be sealed and through adjustments using the software. Compact design. The PROFESSIONAL LINE protection relays are in many ways unique on the market. For example, the standard DIN rail-moun- ted housings allow fast installation at an optimum cost. They have LV and MV practice-oriented termi- nals which are easily accessible and are suited for easy installation on DIN rails. They have a terminal cross section which is especially designed for the connected C.T.s so that they are first choice for those who are not obliged to use door installation. Variety of applications. SEG - PRO- FESSIONAL LINE devices not only prove themselves in the most varied stationary applications - such as in type-tested energy supply systems - but also in mobi- le applications: in construction site systems, container systems, in supply systems for trains and for the most varied maritime applications, they are GL certi- fied. SEG units fulfil the most stringent testing condi- tions. They are resistant to vibration and climate, and fulfil all requirements of IEC 60255. PROFESSIONAL LINE THE DIN-RAIL TRENDSETTER IN MEDIUM-VOLTAGE APPLICATIONS P r o f e s s io n a l L in e Gap in the market closed. Here you will find all common protective functions for low and medium voltage in individual or combined units. The special feature of the PROFESSIONAL LINE products is their attractive price in conjunction with their intelligent DIN bar design which is limited to essentials. Small but efficient - fast and safe. These units manufactured using SMD tech- nology and with universal architecture are used for grid, generator and motor protection. Micro-processor technology used with our larger models ensures top precision and reliability. Especially important too, the relays can process complex measured values, which include: the effective values, real power measuring and communication capability in addition to characte- ristic curves. Flexible adaptation. The PROFES- SIONAL LINE relays let you kill two birds with one stone. With the voltage and frequency relays you can easily select rated voltages and rated frequencies as well as some additional protective functions by means of a DIP switch. The current relays, for example, have a great number of standard characteristic curves which can be used to fit the individual application. Universal supply. The protection relays can be operated with alternating or direct voltage, thanks to a wide-range power pack. This way you can have an electrical supply from the measured value its- elf or any other power source and therefore the pro- duct can be integrated into almost any operating environment. Not only can important rated values be easily adjusted on the unit, but there is no need for a huge variety of associated equipment, which therefore optimises logistics and warehousing. This underlines the cost efficiency of this product line. 2 0 T h e P o w e r P e o p le Easy adjustment Adjustable nominal values Wide range power supply DIN-rail housing IT IS YOUR CHOICE P r o f e s s io n a l L in e Current transformer inputs Voltage transformer inputs Binary inputs Output relay Watchdog relay Protection functions Time overcurrent protection [50/51] ! Directional time overcurrent prot. [67] Earthfault protec. Standard [50N/51N] Resistance earthed/solidly earthed [50N/51N] Earth fault directional feature [67N] Circuit breaker failure protect. [50BF] Voltage protection [27/59] Residual voltage [59N] Phase balance [47] Frequency protection [810/U] Frequency gradient [78] Vector surge [78] Directional power [32/37] Rotor earth fault [64] Negative sequence protection [46] Underexcitation protection [40] Motor protection: Locked rotor [51], thermal protection [49], under- current [37] Differential protection [87T/87G/87L] Special- and additional functions Auto reclosing Reset/blocking Voltage dependent function Time and date Parameter sets Fault memory (non volatile) Communication RS485 Open Data Protocol 3 1 1 1 1 3 4 X I 1 - I X I 1 - E X I 1 - S X I 1 - E - R X I 1 - S - R X R I 1 - I - R X R I 1 - I - E X N 2 - 1 X N 2 - 2 X R W 1 * X U F 2 X U A 1 X U 2 - A C X U 1 - D C X U 1 - E X F 2 X G 2 X A 1 X P 2 - R X S 2 X E 2 X R 1 X M 1 X D 1 - T X D 1 - G X D 1 - L 1 3 1 3 6 6 2 1 1 3 3 3 3 3 3 3 1 1 3 3 3 1 2 2 2 2 2 2 2 2 4 4 2 2 4 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 1 1 1 1 ! ! ! 50 ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! O O ! ! ! ! 1 ! ! O O O O O O O O O O O O O O O O O O ! ! ! ! ! ! ! ! ! ! ! ! ! 1 1 Data and setting ranges of the PROFESSIONAL LINE Current CT inputs Technical datas Voltage CT inputs Binary inputs Output relays (X-types) Voltage supply Power consumption Protection type front housing Setting ranges Time overcurrent protection Earth fault protection sensitive Voltage protection functions Frequency protection functions Frequency gradient Vector surge In = 1 A Pv = 0,1 VA | In = 5 A Pv = 0.1 VA Un = 100 V, 110 V, 230 V, 400 V and XRW to 690 V 50/60 Hz 24 V DC to 60 V DC and 100 V to 230 V AC/DC 250 V AC /1250 VA/5 A 24 V DC/5 A 19-390 V DC / 36-275 V AC max. 4 W IP40 I> = 0.5 - 2 x In, tI> = 0.05 - 100 s resp. a = 0.1 - 2; I>> = 1 - 15 x In, tI>> = 0.05 - 2.5 s IE> = 0.001 - 0.3 x In, tIE> = 0.05 - 100 s; IE>> = 0.001 - 1.5 x In, tIE>> = 0.05 - 1.25 s = 1 - 22 df = 0.5 - 3 Hz/s f< = 0.94 - 1 x fn, tf< = 0 - 10 s; f> = 1 - 1.06 x fn, tf> = 0 - 10 s U< = 0.75 - 1.05 x Un, tU< = 0.05 - 10 s; U> = 0.95 - 1.25 x Un, tU> = 0.05 - 10 s; U0>, = 0.01 - 1.2 x Un, tU0> = 0.07 - 100 s; U2> = 0 - 0.6 x Un, tU2> = 0.07 - 10 s 2 2 T h e P o w e r P e o p le Time overcurrent protection Mains decoupling/-protection Machines Diff-prot. Di. 1 2 3 4 5 6 7 8 910 20 I/IS 0.1 1 10 100 1000 t[s] tI>= 0.1 0.2 0.3 0.4 0.5 0.6 0.8 1.0 1.4 2.0 3.0 4.0 6.0 8.0 10.0 20.0 0.06 The current relays of the PROFESSIONAL LINE offer you a large number of selectable definite time and inverse tripping characteristics. O = Option ! = Standard *also available with special characteristics (grid code) ! Output relays (XR-types) 250 V AC /1500 VA/6 A 24 V DC 144 W/6 A (ohmic) 4.2 A/100 W (L/R = 40 ms) Earth fault protection standard IE> = 0.25 - 1.75 x In, tIE> = 0.05 - 100 s; IE>> = 1 - 15 x In, tIE>> = 0.05 - 1.25 s Housing 75 x 65 x 110 mm (H x B x T) 75 x 224.7 x 110 mm (H x B x T) ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! X R I 1 - E - R 1 3 2 2 1 ! 1 ! ! ! X R N 2 - 1 X R N 2 - 2 3 3 2 2 4 4 1 1 ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! 1 1 ! ! The adjustment ranges listed in the table apply for protection relays in general. For details please refer to the relevant product documentation. CONNECTION EXAMPLES P r o f e s s io n a l L in e 2 4 T h e P o w e r P e o p le Phase voltage HV/MV VT connection Phase current measuring Phase current measuring (2-CT) Earth current measuring with ring core transformer Earth current measuring with Holmgreen - connection Phase voltage LV-direct connection 1-phase measuring Connection type for residual voltage mesuring Connection example XI1-I Housing form X... Housing form XR... relay and XD Connection example XR ... Relays Always live. All the WI LINE products are over-current time relays. The tripping characteristics range from the two-step independent time overcur- rent protection (DEFT), dependent (INV) right down to specialist characteristic curves. As further options, we offer some relays with integra- ted earth current protection. Cleverly sourced. The WI protection relays receive their power supply from the measured current of the current transformers. By using the right combination of current transformer, low-power tripping coil (<0.5 Ws) and the appropriate protective device, you can gain enormous cost savings. Our contribution to this, has been the development of a low-energy tripping principle which can be found in all WI devi- ces. This low-energy tripping principle consists of an energy storage system which is integrated into the WI devices, and which considerably reduces the cur- rent transformer power. Since we know how valuable and cost-intensive building space is, we are especially proud of the fact that our WI devices can be supplied even with smaller transformers. Expensive connection via interposing transformers is therefore not neces- sary. The operating mode, which is independent from auxiliary voltage, guarantees you the greatest flexibi- lity when it comes to using the devices. Of course, we also offer you solutions where standard 1 A or 5 A current transformers are required or where specia- list transformers in compact switchgears are used. For rough conditions. Day in day out - even under the roughest environmental conditi- WI LINE TRIPPING WITHOUT AUXILIARY VOLTAGE W I L in e Customer-oriented design. The protection relays we introduce to you in this line were developed in close co-operation with our customers. This co- operation has resulted in products which will match any circuit breaker com- monly available on the market. Because these relays work independent of auxiliary voltage, they are well suited for self-sustaining transfer and distributi- on stations, local grids and ring-main-units. Current and setting ranges of the WI-Relays WI1-3 and WI2-3 7.2 to 460 A I> from 2 x In I>> = 6 -13.5 x In t I> = 5 -20 s t I>> = 0.01 - 1.5 s WIM1 and WIZ1 I> = 0.8 - 2.3 x In t I> = 0.6 - 20 s WIP1 I> = 0.5 - 2.5 A I>> = 1 - 35 x In I E > = 0.05 - 2 x In I E>> = 0.1 - 9 x In t IE> = 0.06 - 300 s t IE>> = 0.06 - 2 s 2 6 T h e P o w e r P e o p le ons - the WI LINE relays prove to be reliable. For over 15 years more than 23,000 WI relays have been installed and neither dirt, greatly fluctuating temperatures nor high humidity have had any adver- se effect on them. If you wish to employ superior technology even under the most unfavourable condi- tions - then the WI LINE is the right choice for you. Did you know?... that the WIP, flag ship of the WI LINE offers additional functions, which you would not normally expect from a current transformer powered relay? An optional, redundant voltage supply, allows you to have the following additional features, regardless whether a primary current is flowing: ! Display of up-to-date measuring values ! Earthfault protection (IE> 0.05 x I N ) ! Free configuration of the output signals ! Communication via RS485 Robust Low-energy tripping Current trans- former supplied Customer orientated design The communication interface allows you online para- meter setting with WI-Soft, reading of the fault value memory and connection to the SCADA System via the Modbus RTU Protocol. to 1 or 5 A I>> = 2 - 18.5 x In t I>> = 0.05 - 1.5 s to 1 A t I > = 0.06 - 300 s t I>> = 0.06 - 2 s WIC1 16 to 448 A I> = 0.9 - 2.5 x I s t I> = 0.04 - 300 s I E > = 0.2 - 2.5 x I s t IE> = 0.1 - 20 s I>> = 0.9 - 20 x I s t I>> = 0.04 - 3 s COMPACT AND RELIABLE W I L in e WIM1 WIZ1 WIP1 Single functions ANSI Phase overcurrent (independent) 50/51 ! Phase overcurrent (dependent) 50/51 Phase overcurrent (multi-characteristic) 50/51 ! ! Short circuit protection 50/51 ! ! ! Number of overcurrent elements 2 2 2 Earth overcurrent 50N/51N O Number of earth overcurrent elements 2 Line features DIN rail mounting ! Panel mounting ! ! ! Display (measuring values and parameters) ! Setting via buttons ! Setting via hex switches ! ! Setting via DIP switches Setting via code jumpers ! Standard CT (1A /5A) 1 A or 5 A 1 A or 5 A 1 A Special CT (secondary rated current) LED pickup ! ! ! Rated frequency Hz 50/60 50/60 50/60 Fault memory ! Clock ! Password protection ! Electro-impulse/Relay contact output R or E R or E both Number of output relays W = c.o. contacts Input remote tripping ! ! ! Interface O RS 485 interface with Pro Open Data protocol Additional power supply O RS 485 interface with MODBUS-protocol O O 2/3W (R-type) 2/3W (R-type) 3W *please state characteristic on order form ! = Standard O= Option * only WIC1-2 or WIC1-3 2 8 T h e P o w e r P e o p le WIC1 ! ! 2 O ! ! ! ! ! E 50/60 wide range 1 O O O* One of our latest developments is the WIC, which is used in compact ring main units - a device reduced to the essential with an excellent price/performance ratio. The WIC protects mains transformers against over-cur- rent and short circuits, in compact switchboards (Ring Main Units) containing integrated circuit breakers. The DMT and IDMT tripping elements with their multi- characteristics allow you flexibility with your applicati- on. The WIC is also available, as an option with inte- grated earth current supervision. You will see that the WIC has benefits to offer even in the planning stage. Your work can be reduced so that you only need to select one of our four wide- range current transformers with secondary current adapted to the relay. In conjunction with these wide- range current transformers the WIC relay forms a system with an extremely wide operating-current range from 16 - 448 A. The complete system of transformer and relay has a primary short-circuit resi- stance of 62.5/25 kA 1 sec or respectively 52.5/21 kA 3 sec. Its dimensions 170/40/125 mm make the WIC particularly suitable for installation in compact switch- boards. The WIC System provides safe planning. As the system is universally applicable, the varieties you have in stock can be reduced to a minimum. The choice is yours when it comes to parameter set- ting. Depending on the type, the WIC parameters can be set either by way of the communication interface via PC or, alternatively, with a manual SEG parameter setting device, or simply via a DIP or HEX-switch. Either supported by software or with a simple turn, you can simply adjust the tripping and excitation values as well as the tripping characteristic. The WIC is equipped with an integrated fault value memory which you can read via the communication interface. When it comes to servicing and commissioning, addi- tional test bushings on the top of the device make the direct secondary current testing of the complete converter much easier. Once put into operation, the WIC will remain maintenance-free for 25 years. Big selection. Hopefully you will find the protection relay to suit your requirements whilst browsing. In case you do not find a relay, please contact us. Chances are that we would be able to launch another member of the WI LINE in a joint effort. WIC new and forward looking Comfortable parameter setting via PC or handheld. intercept them and minimise grid losses. It is our aim to optimise the use of your equipment. The SYSTEM LINE is integrated into the Station SCADA System by way of the standard protocol IEC 870-5-103, the PROFIBUS DP or MODBUS RTU. Communication channels. To ensure system flexibility, we offer you the follo- wing communication channels for SYSTEM LINE devi- ces: Fibre optic conductors Do you have to bridge great distances? By using fibre optic conductors you can set up potential-free and trouble-free communication with our SYSTEM LINE devices. Distances of up to 2 km can be covered without additional hardware. It is even possible to bridge greater distances with appropriate ampli- fiers/wide-range converters. RS485-Bus Using the world-wide accepted RS485 Bus, you can integrate the devices of the SYSTEM LINE easily, cheaply and reliably into your station management system via a two-wire line. Why don't you simply link several devices to this well-priced serial data bus? We will be pleased to advise you. Modem (RS232) You don't really want to lay data lines or is it not possible to do so? No fear, the data lines are already there. Simply use the conventional telephone net- work/dedicated circuit line for data transfer. This saves you costs in setting up communication chan- nels. ...and, of course, by using commercial converters found on todays market, any combination of the most varied transfer lines is possible. Just talk to us. Types of communications. IEC-870-5-103, Profibus DP or Modbus-RTU - It is your choice. Independent of manufacturers ... ...you can integrate your SYSTEM LINE unit into the station management system via IEC 870-5-103. By using this standard protocol, all relevant device func- tions are easily and safely controlled, monitored and called up from a central location. See our references for more details. Profibus DP/Modbus RTU For industrial applications or simple visualisation systems, we can offer you this automating bus which is standardised throughout Europe. Are you looking for building/facility solutions? Air conditioning, gas and water systems need to be comfortably controlled from one central location? Using the Profibus DP, you can connect your medium-voltage equipment to any automation system without problems. COMMUNICATION IS EVERYTHING C o m m u n ic a t io n Modern communication and linking to systems are the basis for economical and efficient application of your operating components. So that we can offer you maximum comfort, SEG has developed special software tools for all product lines mentioned in this brochure on the basis of stan- dardised communication channels. These tools considerably increase the functionality of the devices. SEG has created solutions which guarantee you most comfortable protection, simplest control and commu- nication links capable of meeting challenges of the future. Below you will find more detailed information concer- ning the individual product lines. Since the SYSTEM LINE-SOFT offers you the most comprehensive com- munication solutions, we will mention it first. Communication links for System Line devices. The great num- ber of communication solutions offered by the SYSTEM LINE helps you save costs. Linking SYSTEM LINE devices together puts you in a situation where you will not need any maintenance staff on site. A fault has occurred? Our communication solutions will support you by actively looking for a fault if one should occur. It goes without saying that your initial fault analysis can be by remote interrogation. If, for example, an earthfault occurs, you simply connect and disconnect various feeders in order to isolate the earthfault. After a fault event, without loosing any time, you can immediately carry out suitable counter measures such as switchovers. Note: More detailed information on internal communi- cation - parameter setting, evaluation and analysis - can be found on pages 4 and 5. Do you require not only pro- tection and control? Of course, you can also expect comfortable support for efficient ener- gy management. Actual measured values can be read remotely therefore you can use your equipment efficiently. This way you avoid load peak loads or 3 0 T h e P o w e r P e o p le Do you expect more than standardised products? We have developed a protocol for you. The SEG Pro Open Data Protocol offers fast and simple data evaluation and effective use of the data recorder andand SL Features of the software SL-Soft HTL-/PL- Soft WI-Soft Reading measuring values ! ! ! Reading, setting protection parameters ! ! ! Loading and storing single line diagrams ! Storing and copying protection parameters ! ! ! Switching parameter sets over ! ! Reading fault memory ! ! ! Reading event memory ! Displaying and evaluating fault records ! ! Synchronising time via PC ! ! ! Multi-device communication ! ! ! Connection RS232 ! ! 1 ! 1 Connection RS485 ! ! Connection CAN-Bus ! Trend recorder ! ! Product Line MODBUS RTU SEG-PRO OPEN DATA PROTOCOL High Tech Line ! ! Professional Line ! WI Line ! ! HTL/PL WIP1 . 1 = RS232/RS485 converter required WIC1 ! ! ! ! ! WIC1-Soft C o m m u n ic a t io n Process automation is your business? By using Profibus DP, standard components can be used (e.g. PLC). This puts you in the position of being able to set up your management system at a reasonable price. Communication channel for High Tech Line, Professional Line and WIP1 devices The software. SEG has developed an opti- mally designed parameter setting and evaluation soft- ware for every line. The software works on any com- mercial PC with a Windows operating system. By using this well-priced software, you do not need to invest in anything else. Installation is quite simple. Thanks to the uniformly designed surface, operation is intuitive. With these software tools you are able to set the parameters for up to 32 devices quickly and simultaneously from one central position. A password protects the communication rights of the user. But that is not everything. The software also allows you to store device data. Stored fault values and possible fault records can be documented... You and your colleagues can assign data sets with the relevant adjustment parameters to all devices and then prepare them comfortably at your desk. Use the software to assist you in project planning. There is hardly any simpler and more comfortable way of achieving optimal safety and accessibility. Especially for the Professional Line. For communication with these relays there is a specially developed interface adapter Type XRS. This module, which can be placed at the side of the device, uses appropriate software to transfer data. The module can be easily refitted and is simple to install. The XRS1 is galvanically isolated from the relay via optical transmission. The bus system. Because the RS485 bus is easy to set up - a simple two-wire line is suf- fient, and allows several devices to be linked. Therefore the RS485 bus represents a simple, well priced communication link for you. More and more customers are using this communication solution, as this bus system is accepted world-wide and the dedi- cated SEG software is available at a reasonable price. Please see our references, so that you will be convin- ced of the opportunities offered by modern communi- cation links. Without extra charge. You can choose between the standardised Modbus RTU and the SEG Open Protocol. Almost all High Tech, Professional and WIP1 devices allow parameter set- ting, monitoring and evaluation via SEG's own Protocol or via MODBUS RTU (not applicable for Professional Line). Transmission of measured values, protection messages or fault values is also no pro- blem. Some High Tech Line devices such as the MRI3 are also capable of transmitting fault records. For connection to a higher-level SCADA system you use the standardised Modbus RTU Protocol. On the basis of this standardised protocol and in conjunction with the SEG software tools you are able to evaluate your devices in comfort. 3 2 T h e P o w e r P e o p le Interface adapter XRS for PROFESSIONAL LINE Relay PROFI- BUS DP ! 1 ! 1 1 = Profibus converter required We are at your service - 35 locations on five continents. We have customers all over the world and for this reason we have branches around the world offering comprehensive services. This does not only cover technical service for servicing and maintaining our devices, but also competent consultation and support during commissioning of devices. Here is a short outli- ne of the services we offer: Selection of devices - Pre Sales Service. Profit from the experience of our sales force. Take your time for a consultation. On the basis of many years of experien- ce we will find the tailor-made solution for your appli- cation. We will be pleased to put all of our know-how at your disposal. We know from experience that opti- mum selection of equipment leads to considerable cost savings. Engineering. Are you looking for specific engineering services? E.g. for configuration of the interlocking conditions of a feeder management system? Talk to our team of specialists. After Sales Service. We want satisfied customers, therefore we offer advi- ce and service after the sale of our products. For que- ries and further information, please contact our Service Team. Grid calculation. From short-circuit cal- culations via the preparation of a time distance graph and the calculation of the adjustment values of SEG protection devices, right down to the selection of the devices, our specialists offer you competent advice to meet the specific requirements of your system. Device configuration and set- ting. Do you expect more than standard soluti- ons? No problem. We will configure and set the para- meters of the devices you purchase from us exactly to your specifications. Repairs. The servicing and testing of devices is carried out by the service team at SEG headquarters in Kempen. Here, too, you profit from our excellent location; i.e. to other industrial areas, other European countries and Dsseldorf International Airport. Commissioning support with protection and control devices (secondary injection testing). We ensure you that you only have to pay for those services which you actually take advantage of. Commissioning support for function and protection units is invoiced on the basis of actual costs. Commissioning of protection devices usually requires secondary-injection testing of the devices. We would be pleased to provide you with skilled personnel and special test equipment. Check our homepage at www.newage-avkseg.com for our world-wide sales and service partners or just visit our document/product server doc.newage-avkseg.com. WE ARE AT 35 LOCATIONS ON FIVE CONTINENTS WELCOME Selection Configuration and setting Commissioning support 3 4 T h e P o w e r P e o p le Comprehensive documentation of all products covered by the Business Segment Electronic Devices can be found on our product CD. Order your copy under: +49 (0) 21 52/14 5-6 35 Product catalogue in the Internet Our Homepage Always up to date documentation material can be found on our document server: doc.seg-pp.com. If you want to know what other services SEG Power Protection can offer you, please visit our Internet pages under: www.seg-pp.com P M _ P r o d F i n d _ 0 7 . 0 5 _ G B T e c h n i c a l
d a t a
s u b j e c t
t o
c h a n g e
w i t h o u t
n o t i c e ! Schaltanlagen-Elektronik-Gerte GmbH & Co.KG Division Power Protection Krefelder Weg 47 ! D - 47906 Kempen (Germany) P.O. Box 10 07 55 ! D - 47884 Kempen (Germany) Internet Homepage http://www.seg-pp.com Documentation http://doc.seg-pp.com Sales team Phone: +49 (0) 21 52 1 45 - 1 ! Fax.: +49 (0) 21 52 1 45 - 3 54 e-mail: electronics@newage-avkseg.com Service Phone: +49 (0) 21 52 1 45 - 2 37 ! Fax.: +49 (0) 21 52 1 45 - 4 55 e-mail: application@newage-avkseg.com THE POWER PEOPLE seg-pp.com Visit us at