Академический Документы
Профессиональный Документы
Культура Документы
November 1996
TOOL
OPERATING
MANUAL
Caterpillar DataView
131-5050 DataView Group
131-5051 DataView Portable TechStation Group
SMCS Code 0000
Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Maintenance
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Introduction
Analog Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Frequency Sensors . . . . . . . . . . . . . . . . . . . . . . . 10
DataView Specifications . . . . . . . . . . . . . . . . . . . . 14
Connections and Controls on
DataView Hardware . . . . . . . . . . . . . . . . . . . . . . . . 16
Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Locating and Mounting DataView Hardware. . . . . 18
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Using DataView Hardware at the PC . . . . . . . . . 18
DataView Portable TechStation . . . . . . . . . . . . . 18
Using DataView Hardware Near Sensors . . . . . . 19
Mounting DataView Hardware on a Machine . . . 19
Selecting PC for Use with DataView . . . . . . . . . . 19
Powering DataView Hardware . . . . . . . . . . . . . . 20
Internal Power . . . . . . . . . . . . . . . . . . . . . . . . . 20
External AC Power . . . . . . . . . . . . . . . . . . . . . . . . 20
External DC Power. . . . . . . . . . . . . . . . . . . . . . . . 20
Cigarette Lighter . . . . . . . . . . . . . . . . . . . . . . . 21
Operating DataView. . . . . . . . . . . . . . . . . . . . . . . . 22
Connecting DataView to a PC . . . . . . . . . . . . . . . 22
or Histogram Tools. . . . . . . . . . . . . . . . . . . . . . 25
Data Logging and Storing Data . . . . . . . . . . . . . . . 27
Setup Logger Tool . . . . . . . . . . . . . . . . . . . . . . . 27
View Logger Tool . . . . . . . . . . . . . . . . . . . . . . . . 28
Strip Chart Tool . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Saving Data on Files . . . . . . . . . . . . . . . . . . . . . . 29
Measuring Frequency (Hz) and %Duty Cycle
with DataView. . . . . . . . . . . . . . . . . . . . . . . . . . 30
Personal Computer
SIS Tools
Electronic
Technician
Software
Program
*
DataView
Software
Program
RS232
Caterpillar
Communications
Adapter
Features
Parallel Port
Caterpillar
DataView
Hardware
6 Analog Inputs:
Pressure
Temperature
Blowby
Position
Data Link
ECM
3 Frequency Inputs:
RPM
Hz
Duty Cycle
Hyd. Flow
Fuel Flow
Nomenclature
131-5050 DataView Group
19
5
2
11
10
12
13
3
6
14
2
3
1
24
15
7
22
10
JERD2163
131-5050
137-0172
137-0169
5
6
7
8
9
10
11
18
17
16
Group.
Refer to Chart B for item identification.
Chart A.
131-5050 DataView Nomenclature
1
2
3
4
20
Part No.
23
11
Item
21
Chart B.
131-5051 DataView Portable TechStation Group
Nomenclature
Description
DataView Software
DataView Hardware
DataView Mounting Kit
Flash Programming CableDataView Front
131-5059 Flash Programming CableDataView Rear
131-5053 DataView to PC parallel port cable
(short)
131-5052 AC Power Adapter, 90 to 264 VAC, 47
to 63 Hz
131-5047 AC Power Cable, 110 VAC (USA plug)
137-0171 European Power Adapter
NEHS0662 Hardware Operating Instructions
JEBD3004 Software Program Operating
Instructions
142-2415 Test Connector (for parallel port test)
Item
1
2
3
4
5
6
7
8
9
10
11
12
Part No.
Description
Chart B.
131-5051 DataView Portable TechStation Group
Nomenclature (continued)
Item
Part No.
13
131-5065
Chart C.
Optional Components for DataView
Item
Description
14
15
16
17
18
19
20
21
22
23
24
Optional Components
6
7
7
5
4
Part No.
Part No.
Description
131-5058 Generic
This foam fits in the
Foam Insert 137- 0173 Case and has
locations for DataView and
a square hole for almost any
laptop PC. It also has a
location for the Caterpillar
Communications adapter.
137-0173 DataView This case has an access
Carrying
door in the front to allow
Case
DataView to be used without
removing it from the case.
The foam insert must be
ordered separately, as
listed below.
138-8779 Top Foam Replaces the generic PC
Insert (only) foam in the DataView case
to allow the Cat Portable PC
for Cat
(Itronix), with CD ROM drive
Portable
TechStation and Cat Communications
adapter, to be used with
PC
131-5051 DataView
Portable TechStation.
Fits in the 137-0173 Case
137-0174 Cat
Portable PC and has locations for
Foam Insert DataView on the lower level
(4 piece) for and the Cat Portable PC
DataView (Itronix), with CD ROM and
Cat Communications
carrying
adapter on the upper level.
case.
Also includes a DataView
blank foam and lid foam.
137-0168 External
11 to 40 VDC power cable
Power
for DataView. Length, 5 m
Cable
(18 ft).
133-6975 European 220 VAC DataView power
Power
cable with European style
Cable
connector. (fits 131-5052
AC Power Adapter)
131-0170 Cigarette 12 VDC power cable for
Lighter
DataView.
Cable
An explanation of
ANALOG SENSORS
Chart D.
Pressure Sensor and Auto ID Cables
Part No.
Description
Auto ID Cables
Used for analog sensor automatic identification
and setup. When the proper auto ID cable is
installed between the sensor and DataView, the
sensor will be automatically identified and set up
ready for operation by DataView. These cables
come with a piece of heat shrinkable tubing, so
they can be permanently installed on the sensors.
Auto ID is possible because each cable has a
different resistor installed in it to identify the sensor
it is used with.
Chart E.
Pressure Sensor and Auto ID Cables Specifications
Description
Accuracy
Overpressure
Connection
Specification
Chart G.
RTD Temperature Sensor Specifications
Description
General
An auto
ID cable is not required for RTD temperature
sensors. They plug directly into DataView analog
Device) sensors to measure temperature.
Type
Temperature Range
Accuracy
Cable Length
These RTD
Specification
Chart H.
Exhaust RTD Temperature Sensor Specifications
Description
General
Chart F.
RTD Temperature Sensors
Part No.
Description
4C-6264
RTD Temperature
Sensor
RTD Temperature
Sensor
RTD Temperature
Sensor
RTD Temperature
Sensor
4C-6265
4C-6266
4C-6267
Type
Specification
Length
Temperature Range
Accuracy
Cable Length
Specification
Chart .
Hand Held RTD Temperature Probes
Part No.
Description
Specification
4C-6496
4C-6497
Chart J.
Hand Held RTD Temperature Probe Specifications
Description
Probe Type
Probe Length
Handle Length
Temperature Range
Accuracy
Cable Length
Specification
Chart K.
Blowby Sensors
Part No.
8T-2685
131-5066
1U-8860
131-5067
Description
CATERPILLAR
8T1002
1 INCH 25.4 MM
Chart L.
Position Sensor
Part No.
Description
8T-1002
131-5065
6V-6042
5P-4814
9U-6909
Chart M.
Photo Pickup Speed Sensor
FREQUENCY SENSORS
These sensors are for measuring speed (rpm),
frequency (Hz), %duty cycle, or flowmeters.
Frequency sensors provide a frequency or pulsed
output signal. These sensors can be used only in
frequency channels 7, 8, and 9 of DataView.
The
Part No.
Description
9U-5140
6V-3137
6V-3138
1U-6605
6V-0093
4C-6919
NOTICE
Do not plug frequency sensors into the analog
channels. This can result in damage to the
frequency sensors.
Chart N.
Injection Line Speed Sensor
Part No.
Description
10
Chart O.
Tachometer Generator Speed Sensor
Part No.
Description
5P-7360
5P-1759
Chart P.
Flywheel Top Dead Center Magnetic Speed Sensors
Part No.
Description
8T-5184
6V-2197
8T-5185
9U-7506
6V-2199
6V-3093
7X-1171
11
Specification
;
;
EXTERNAL
POWER
SUPPLY
SUPPLY
METER
RETURN
METER
Chart Q.
Magnetic Pickup Speed Sensors
Part No.
8L-4171
9G-6724
6V-4156
9U-7506
Description
General Purpose
Magnetic Speed
Sensor
Magnetic Speed
Sensor
Adapter Cable
(required for above
sensors)
Magnetic Adapter
Cable (required for
above sensors)
OUTPUT
Specification
1U9500
FUEL FLOW
COMMUNICATOR
STATUS
POWER ON
Phono jack to
DataView
Illustration 17. Caterpillar Fuel Flow Communicator.
Refer to Chart R for additional information.
Chart R.
Caterpillar Fuel Flow Communicator and Fuel Flowmeters
Part No.
1U-9500
1U-5450
1U-5430
1U-5440
12
Description
Hydraulic Flowmeters
for Frequency Channels
4
5
Chart S.
Caterpillar Fuel Flowmeter
Illustration 19. Hydraulic Flowmeters for Frequency
Item
Part No.
1
2
3
4
5
6
7
8
9
1U-5450
4C-9764
4C-9758
4C-9759
4C-9760
4C-9761
1U-5305
1U-5306
1U-5420
1U-5299
Description
Chart T.
Hydraulic Flowmeters for Frequency Channels
Part No.
Description
4C-9911
Hydraulic Flowmeter
4C-9436
Hydraulic Flowmeter
4C-9912
Hydraulic Flowmeter
4C-9913
Hydraulic Flowmeter
4C-8687
Hydraulic Flowmeter
4C-9914
Hydraulic Flowmeter
4C-8686
Hydraulic Flowmeter
Specification
8 to 50 L/min
(2 to 12 gpm)
12 to 120 L/min
(3 to 25 gpm)
20 to 220 L/min
(5 to 50 gpm)
30 to 300 L/min
(8 to 80 gpm)
45 to 450 L/min
(10 to 100 gpm)
50 to 550 L/min
(12 to 150 gpm)
60 to 700 L/min
(15 to 180 gpm)
13
DataView Specifications
Inputs
Size
DataView PC Specifications
Description
Specification
(Minimum PC Requirements)
Weight
Computer
Number of Analog
Channel Inputs
Connector Type
Specification
Six
Specification
Specification
14
Specification
Description
Type of RS232
RPM
10
50
100
10
20 DO NOT
USE
50
75
100
400
+/- 1RPM Accuracy
1000
in this area
4000
5000
6000
7000
8000
9000
9999
150
200
256
Baud Rates
Voltage
Software Requirements
Specification
Channels
DO NOT
USE
Memory
Sample Rate
Recording Time
Illustration 20.
Description
Specification
Specification
Pre Trigger
Auto Trigger
Manual Trigger
15
Specification
1
CHAN.
1
2
CHAN.
2
3
CHAN.
3
4
CHAN.
4
5
CHAN.
5
CHAN.
6
CHAN.
7
8
CHAN.
8
5
SET
POINT
INPUTS
CHAN.
9
CH7
ANALOG CHANNELS
ERPILLAR
FREQUENCY CHANNELS
131-5050 DataView
DATA LOGGER
MEMORY
FULL
OFF
LOGGING
OFF/ON
CH8
POWER
ON
AUTO
TRIGGER
CHARGE
1.
7.
is on slow charge.
-DataView Front.
2.
3.
4.
5.
6.
16
Rear Panel
131-5050 DataView
Power
MEMORY CARD
TO PC PARALLEL
PRINTER PORT
PRINTER
1.
2.
3.
4.
17
DataView Portable
TechStation
Operation
Using DataView Hardware at
the PC
The short
18
Portable PC (Itronix).
A test
(1-800-843-7237).
NOTE:
NOTICE
The DataView hardware case is not a sealed
enclosure and damage can result by exposing it to
rain, moisture, excessive heat, or excessive
vibration. Do not mount on track-type tractors.
19
External AC Power
Internal Power
1
program.
charged.
External DC Power
NOTICE
Always connect the red clip lead to the battery
positive terminal and the black clip to the frame of
the machine only. Do not connect the black lead
to the battery negative terminal as this can cause
damage to DataView hardware.
20
Plug the
NOTICE
The 137-0170 Cable is for 12 VDC operation only.
Do not plug it into a 24 Volt cigarette lighter socket
which is found on some Caterpillar machines or
the adapter may be damaged.
21
Operating DataView
To do this,
histogram tools.
There is information
All the
Connecting DataView to a PC
hardware.
Sensor Identification
Analog Sensors
Pressure
Temperature
Blowby Probe
Position Probe
Frequency Sensors
Speed sensors
Hz
Duty Cycle
Flow
22
screen.
6.
1.
2.
3.
4.
NOTE:
5.
23
"Setup" tool.
measurement sections.
Double
Users" manual.
This means
DataView
is used.
Failed Sensors
If a sensor output exceeds its normal operating
range, "FAIL" will appear in the output column. Try
properly.
24
Displaying Graphics
push-button.
details.
The output
Chart" tool
The
diagram in
chart.
25
NOTE:
histogram.
push-button.
traces.
Histogram Tool
The "Histogram" tool allows the user to view a
histogram bar chart for one selected channel,
showing the amount of time that the channel input
was in various ranges. This allows the user to look
for potential problems in a machine, by
determining if the amount of time spent at various
measurements, while the machine is being
operated, is appropriate.
26
enabled.
NOTE:
27
the PC. The user can either retrieve the log from
the PC.
The "Log
logged data.
push-buttons.
28
File Structure
several documents.
log.
hardware.
To zoom
To view and manipulate files and documents from
push-button.
NOTE:
Once a
position for the left cursor, then push the left mouse
29
Measurement Instructions
NOTICE
Do not apply over 40 Volts AC or DC maximum to
any DataView channel input. The 9U-7505 High
Voltage Adapter must be used for all voltages over
40 Volts and up to 600 Volts maximum. Use the
adapter only on the frequency channels for
measuring frequency or %duty cycle. It plugs
directly into any frequency channel (channels 7, 8,
or 9).
Freq. Input
DataView contains a frequency (Hz) measurement
2
5
Pin
1
Shield (Optional)
2 hi
Input 40Volts
3 low Signal Max
4
5
Switchcraft 05BL5M
Connector
The %duty
(Photohead Power).
cycle.
Direct Input to
Frequency Inputs
Using 9U-7505 High
Voltage Adapter
6V-4960 AC Current
Probe
9U-5795 AC/DC
Current Probe
Voltage
Range
Required Current
Flowing in Circuit
to be Measured
30
9U-5795
previous section.
31
Arrangements.
1.
proper operation.
2.
3.
32
4.
NOTICE
Fuel temperature cannot be measured at the
flowmeters with DataView. A separate RTD
temperature sensor must be used in an analog
channel.
33
Maintenance
Service
1.
2.
address:
into place.
3.
Peoria, IL 61629-9010
screws.
1-800-541-8665................................Inside Illinois
It may be necessary to
1-800-542-8665................................Outside Illinois
1-309-675-6618................................Fax
can be installed.
34
NOTES
35
1996
Caterpillar
NEHS0662