Вы находитесь на странице: 1из 2

T

h
e

i
n
f
o
r
m
a
t
i
o
n

p
r
o
v
i
d
e
d

i
n

t
h
i
s

d
o
c
u
m
e
n
t
a
t
i
o
n

c
o
n
t
a
i
n
s

g
e
n
e
r
a
l

d
e
s
c
r
i
p
t
i
o
n
s

a
n
d
/
o
r

t
e
c
h
n
i
c
a
l

c
h
a
r
a
c
t
e
r
i
s
t
i
c
s

o
f

t
h
e

p
e
r
f
o
r
m
a
n
c
e

o
f

t
h
e

p
r
o
d
u
c
t
s

c
o
n
t
a
i
n
e
d

h
e
r
e
i
n
.
T
h
i
s

d
o
c
u
m
e
n
t
a
t
i
o
n

i
s

n
o
t

i
n
t
e
n
d
e
d

a
s

a

s
u
b
s
t
i
t
u
t
e

f
o
r

a
n
d

i
s

n
o
t

t
o

b
e

u
s
e
d

f
o
r

d
e
t
e
r
m
i
n
i
n
g

s
u
i
t
a
b
i
l
i
t
y

o
r

r
e
l
i
a
b
i
l
i
t
y

o
f

t
h
e
s
e

p
r
o
d
u
c
t
s

f
o
r

s
p
e
c
i
f
i
c

u
s
e
r

a
p
p
l
i
c
a
t
i
o
n
s
.
I
t

i
s

t
h
e

d
u
t
y

o
f

a
n
y

s
u
c
h

u
s
e
r

o
r

i
n
t
e
g
r
a
t
o
r

t
o

p
e
r
f
o
r
m

t
h
e

a
p
p
r
o
p
r
i
a
t
e

a
n
d

c
o
m
p
l
e
t
e

r
i
s
k

a
n
a
l
y
s
i
s
,

e
v
a
l
u
a
t
i
o
n

a
n
d

t
e
s
t
i
n
g

o
f

t
h
e

p
r
o
d
u
c
t
s

w
i
t
h

r
e
s
p
e
c
t

t
o

t
h
e

r
e
l
e
v
a
n
t

s
p
e
c
i
f
i
c

a
p
p
l
i
c
a
t
i
o
n

o
r

u
s
e

t
h
e
r
e
o
f
.
N
e
i
t
h
e
r

S
c
h
n
e
i
d
e
r

E
l
e
c
t
r
i
c

I
n
d
u
s
t
r
i
e
s

S
A
S

n
o
r

a
n
y

o
f

i
t
s

a
f
f
i
l
i
a
t
e
s

o
r

s
u
b
s
i
d
i
a
r
i
e
s

s
h
a
l
l

b
e

r
e
s
p
o
n
s
i
b
l
e

o
r

l
i
a
b
l
e

f
o
r

m
i
s
u
s
e

o
f

t
h
e

i
n
f
o
r
m
a
t
i
o
n

c
o
n
t
a
i
n
e
d

h
e
r
e
i
n
.
Sep 1, 2014
1
Product data sheet
Characteristics
LV429546
circuit breaker Compact NSX100B - TMD - 25
A - 3 poles 2d
Main
Product or component
type
Circuit breaker
Device short name Compact NSX100B
Circuit breaker applica-
tion
Distribution
Poles description 3P
Protected poles de-
scription
2t
Network type AC
Network frequency 50/60 Hz
[In] rated current 100 A ( 40 C )
[Ui] rated insulation
voltage
800 V AC 50/60 Hz
[Uimp] rated impulse
withstand voltage
8 kV
[Ue] rated operational
voltage
690 V AC 50/60 Hz
Breaking capacity code B
Breaking capacity Icu 40 kA at 220/240 V AC 50/60 Hz conforming to
IEC 60947-2
Icu 25 kA at 380/415 V AC 50/60 Hz conforming to
IEC 60947-2
Icu 20 kA at 440 V AC 50/60 Hz conforming to IEC
60947-2
Icu 15 kA at 500 V AC 50/60 Hz conforming to IEC
60947-2
40 kA at 240 V AC 50/60 Hz conforming to NEMA
AB1
20 kA at 480 V AC 50/60 Hz conforming to NEMA
AB1
[Ics] rated service
breaking capacity
Ics 7.5 kA 500 V AC 50/60 Hz conforming to IEC
60947-2
Ics 40 kA 220/240 V AC 50/60 Hz conforming to IEC
60947-2
Ics 25 kA 380/415 V AC 50/60 Hz conforming to IEC
60947-2
Ics 20 kA 440 V AC 50/60 Hz conforming to IEC
60947-2
Suitability for isolation Yes conforming to IEC 60947-2
Yes conforming to EN 60947-2
Utilisation category Category A
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection
functions
LI
Trip unit rating 25 A ( 40 C )
Protection type Overload protection (thermal)
Short-circuit protection (magnetic)
Pollution degree 3 conforming to IEC 60664-1
2
Complementary
Control type Toggle
Mounting mode Fixed
Mounting support Backplate
Upside connection Front
Downside connection Front
Mechanical durability 50000 cycles
Electrical durability 50000 cycles 440 V In/2 conforming to IEC 60947-2
30000 cycles 440 V In conforming to IEC 60947-2
20000 cycles 690 V In/2 conforming to IEC 60947-2
10000 cycles 690 V In conforming to IEC 60947-2
Connection pitch 35 mm
Local signalling Positive contact indication
Long time pick-up adjstment type Ir Adjustable
Long time pick-up adjustment range 0.7...1 x In
Long time delay adjustment type Fixed
[Tr] long-time delay adjustment 15 s 6 x Ir
120...400 s 1.5 x In
Short-time pick-up adjustment type Isd Fixed
[Isd] short-time pick-up adjustment range 300 A
Short-time delay adjustment type Fixed
Height 161 mm
Width 105 mm
Depth 86 mm
Product weight 2.05 kg
Environment
Electrical shock protection class Class II
Standards EN 60947-2
IEC 60947-2
NEMA AB1
UL 508
Product certifications CSA
UL
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -35...70 C
Ambient air temperature for storage -55...85 C
Offer Sustainability
Sustainable offer status Green Premium product
RoHS
Compliant - since 0819 - Schneider Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Product environmental profile Available
Product end of life instructions Available Download End Of Life Manual

Вам также может понравиться