2014-09-01 Huawei Proprietary - Restricted Distribution Page1, Total7
3G UE Protocol timers, counters, other parameters and default configurations
Timers for UE Timer Start Stop At expiry T300 Transmission of RRC CONNECTION REQUEST Reception of RRC CONNECTION SETUP Retransmit RRC CONNECTION REQUEST if V300 =< N300, else go to Idle mode T302 Transmission of CELL UPDATE/URA UPDATE Reception of CELL UPDATE CONFIRM/URA UPDATE CONFIRM Retransmit CELL UPDATE/URA UPDATE if V302 =< N302, else, go to Idle mode T304 Transmission of UE CAPABILITY INFORMATION Reception of UE CAPABILITY INFORMATION CONFIRM Retransmit UE CAPABILITY INFORMATION if V304 =< N304, else initiate a cell update procedure T305 Entering CELL_FACH or URA_PCH or CELL_PCH state. Reception of CELL UDPATE CONFIRM/URA UPDATE CONFIRM. Entering another state. Transmit CELL UPDATE if T307 is not activated and the UE detects in service area. Otherwise, if T307 is not active, start T307. T307 When the timer T305 has expired and the UE detects out of service area. When the UE detects in service area. Transit to idle mode T308 Transmission of Not stopped Transmit RRC
Document Title Security Level
2014-09-01 Huawei Proprietary - Restricted Distribution Page2, Total7
Timer Start Stop At expiry RRC CONNECTION RELEASE COMPLETE CONNECTION RELEASE COMPLETE if V308 <=N308, else go to idle mode. T309 Upon reception of CELL CHANGE ORDER FROM UTRAN message Successful response to a connection establishment request in the new cell. Resume the connection to UTRAN T310 Transmission of PUSCH CAPACITY REQUEST Reception of PHYSICAL SHARED CHANNEL ALLOCATION Transmit PUSCH CAPACITY REQUEST if V310 =< N310, else procedure stops. T311 Reception of PHYSICAL SHARED CHANNEL ALLOCATION message with the CHOICE PUSCH allocation set to PUSCH allocation pending. Reception of PHYSICAL SHARED CHANNEL ALLOCATION message with CHOICE PUSCH allocation set to PUSCH allocation assignment. UE may initiate a PUSCH capacity request procedure. T312 When the UE starts to establish dedicated CH When the UE detects N312 in sync indication from L1. The criteria for physical channel establishment failure is fulfilled T313 When the UE detects consecutive N313 out of sync indication from L1. When the UE detects consecutive N315 in sync indication from L1. The criteria for Radio Link failure is fulfilled T314 When the criteria for radio link failure are fulfilled. The timer is started When the Cell Update procedure has been completed. See subclause 8.3.1.13
Document Title Security Level
2014-09-01 Huawei Proprietary - Restricted Distribution Page3, Total7
Timer Start Stop At expiry if radio bearer(s) that are associated with T314 exist of if only RRC connection exists. T315 When the criteria for radio link failure are fulfilled. The timer is started only if radio bearer(s) that are associated with T315 exist. When the Cell Update procedure has been completed. See subclause 8.3.1.14 T316 When the UE detects out of service area in URA_PCH or CELL_PCH state When the UE detects in service area. Initiate cell update procedure if in service area is detected. Otherwise start timer T317, transit to CELL_FACH state and initiate cell update procedure when the UE detects in service area. T317 When the T316 expires or when in CELL_FACH state, the UE detects out of service area. When the UE detects in service area. Transit to idle mode
Document Title Security Level
2014-09-01 Huawei Proprietary - Restricted Distribution Page4, Total7
Counters for UE Counter Reset Incremented When reaching max value V300 When initiating the procedure RRC connection establishment Upon expiry of T300. When V300 > N300, the UE enters idle mode. V302 When initiating the procedure Cell update or URA update Upon expiry of T302 When V302 > N302 the UE enters idle mode. V304 When sending the first UE CAPABILITY INFORMATION message. Upon expiry of T304 When V304 > N304 the UE initiates the Cell update procedure V308 When sending the first RRC CONNECTION RELEASE COMPLETE message in a RRC connection release procedure. Upon expiry of T308 When V308 > N308 the UE stops re-transmitting the RRC CONNECTION RELEASE COMPLETE message. V310 When sending the first PUSCH CAPACITY REQUEST message in a PUSCH capacity request procedure Upon expiry of T310 When V310 > N310 the UE stops re-transmitting the PUSCH CAPACITY REQUEST message.
Document Title Security Level
2014-09-01 Huawei Proprietary - Restricted Distribution Page5, Total7
UE constants and parameters Constant Usage N300 Maximum number of retransmissions of the RRC CONNECTION REQUEST message N302 Maximum number of retransmissions of the CELL UPDATE / URA UPDATE message N304 Maximum number of retransmissions of the UE CAPABILITY INFORMATION message N308 Maximum number of retransmissions of the RRC CONNECTION RELEASE COMPLETE message N310 Maximum number of retransmission of the PUSCH CAPACITY REQUEST message N312 Maximum number of in sync received from L1. N313 Maximum number of successive out of sync received from L1. N315 Maximum number of successive in sync received from L1 during T313 is activated.
Document Title Security Level
2014-09-01 Huawei Proprietary - Restricted Distribution Page6, Total7
UE Timer and Constant: The following settings can only be changed when call status is Idle . T300 RRC Conn Req Retransmit Timer This setting determines how long the UE waits for the RRC Connection Setup after sending an RRC Connection Setup Request. T300 can be set to one of the following values: 400, 600, 800, 1000, 1200, 1400, 1600, 1800, 2000, 3000, 4000, 6000, 8000 ms. N300 RRC Conn Req Max Retransmits This setting specifies the maximum number of retransmissions of the RRC Connection Request message. N300 can be set to any integer value from 0 to 7. T312 Link Establishment Timer (Idle) This setting determines how long the UE waits for an N312 "in-sync" indication from layer 1 when establishing a dedicated channel and the connection status is Idle. T312 can be set to any integer value from 1 to 15. T312 Link Establishment Timer (Connected) This setting determines how long the UE waits for an N312 "in-sync" indication from layer 1 when establishing a dedicated channel in connected status. The value 0 is not used. N312 Link Establishment In-Sync Count (Idle) This setting specifies the number of " in-syncs" required when establishing a dedicated channel when the connection status is Idle. N312 can be set to one of the following values: 1, 2, 4, 10, 20, 50, 100, 200, 400, 600, 800, 1000. N312 Link Establishment In-Sync Count (Conn.) This setting specifies the number of " in-syncs" required when establishing a dedicated channel in connected status. N312 can be set to one of the following values: 1, 2, 4, 10, 20, 50, 100, 200, 400, 600, 800, 1000. T313 Out-of-Sync Reception Timer
Document Title Security Level
2014-09-01 Huawei Proprietary - Restricted Distribution Page7, Total7
3GPP TS 25.331 8.5.6 states that after receiving N313 consecutive "out of sync" indications from layer, the UE shall start the T313 timer. Upon receiving N315 successive "in sync" indications from layer 1, the UE shall stop and reset the T313 timer. If T313 expires, a "Radio Link failure" has occurred, and the UE shall drop the call. N313 Successive Out-Of-Sync Reception Max N313 specifies the maximum number of successive "out of sync" received from L1. N313 can be set to one of the following integer values: 1, 2, 4, 10, 20, 50, 100, 200. N315 Successive In-Sync Reception Counter N315 specifies the maximum number of successive "in sync" received from L1 during T313 is activated. N315 can be set to one of the following integer values: 1, 2, 4, 10, 20, 50, 100, 200, 400, 600, 800, 1000. T308 RRC Conn Release Comp Retransmit Timer T308 specifies the time between the transmissions of RRC Connection Release Complete message. N308 RRC Conn Release Comp Max Retransmits N308 specifies the maximum number of retransmissions of the RRC CONNECTION RELEASE COMPLETE message. T3212 Periodic Location Update Timer T3212 specifies how often the UE will perform the periodic location update procedure. It is signaled in SIB1. When T3212 is set to zero, the UE will regard the timer to be infinite.