C6, C7, C12, C23 C1, C, C8, C16, C19, C22 Width, b = 450 mm Total depth, D = 450 mm Dia. of bar1 = 20 mm No of bar1 = 4 - Dia. of bar2 = 25 mm No of bar2 = 0 - Ast = 1610.0 mm2 Dia. Of stirrups = 8 mm Cover = 50 mm Cover, Cmin = 58 mm Minimum cover to the tension steel Eff.cover d', = 68 mm Eff. Depth, d = 382 mm fck = 30 Mpa fy = 500 Mpa Ec = 27386.1 Mpa Es = 200000 Mpa Depth of N.A., Xu = 144.1 mm Moment, Mw = 118 kNm Working moment x1 = 305.9 mm Distance measured from the elastic neutral axis to the point at which strain 1 is requires Ic = 2090361300 mm 4 MI if the cracked section 1 = 0.00126 - a = 450 mm Distance from compression face to the point at which the crack width is being calculated since max cracking occurs on tension face m = 0.00108 - of the beam, then b = D Distance bet. Bars = 104.666667 mm acr = 75.8 mm Distance from the point under consideration to the surface of the nearest longitudinal bar Wcr = 0.2196 mm Permissible crack width 0.232 mm Cmin Cmin acr acr d N A x b Column Numbers C17 C4, C5, C10, C11 Width, b = 450 mm Total depth, D = 450 mm Dia. of bar1 = 20 mm No of bar1 = 5 - Dia. of bar2 = 25 mm No of bar2 = 0 - Ast = 1924.0 mm2 Dia. Of stirrups = 8 mm Cover = 50 mm Cover, Cmin = 58 mm Minimum cover to the tension steel Eff.cover d', = 68 mm Eff. Depth, d = 382 mm fck = 30 Mpa fy = 500 Mpa Ec = 27386.1 Mpa Es = 200000 Mpa Depth of N.A., Xu = 172.2 mm Moment, Mw = 138 kNm Working moment x1 = 277.8 mm Distance measured from the elastic neutral axis to the point at which strain 1 is requires Ic = 2090361300 mm 4 MI if the cracked section 1 = 0.00134 - a = 450 mm Distance from compression face to the point at which the crack width is being calculated since max cracking occurs on tension face m = 0.00120 - of the beam, then b = D Distance bet. Bars = 78.5 mm acr = 68.5 mm Distance from the point under consideration to the surface of the nearest longitudinal bar Wcr = 0.2285 mm Permissible crack width 0.232 mm Cmin Cmin acr acr d N A x b Column numbers C13 Width, b = 600 mm Total depth, D = 600 mm Dia. of bar1 = 32 mm No of bar1 = 4 - Dia. of bar2 = 25 mm No of bar2 = 0 - Ast = 3217.0 mm2 Dia. Of stirrups = 8 mm Cover = 50 mm Cover, Cmin = 58 mm Minimum cover to the tension steel Eff.cover d', = 74 mm Eff. Depth, d = 526 mm fck = 30 Mpa fy = 500 Mpa Ec = 27386.1 Mpa Es = 200000 Mpa Depth of N.A., Xu = 216.0 mm Moment, Mw = 271 kNm Working moment x1 = 384.0 mm Distance measured from the elastic neutral axis to the point at which strain 1 is requires Ic = 7276578800 mm 4 MI if the cracked section 1 = 0.00104 - a = 600 mm Distance from compression face to the point at which the crack width is being calculated since max cracking occurs on tension face m = 0.00090 - of the beam, then b = D Distance bet. Bars = 150.666667 mm acr = 89.6 mm Distance from the point under consideration to the surface of the nearest longitudinal bar Wcr = 0.2070 mm Permissible crack width 0.232 mm Cmin Cmin acr acr d N A x b Column numbers C18 Width, b = 450 mm Total depth, D = 450 mm Dia. of bar1 = 20 mm No of bar1 = 4 - Dia. of bar2 = 25 mm No of bar2 = 0 - Ast = 1610.0 mm2 Dia. Of stirrups = 8 mm Cover = 50 mm Cover, Cmin = 58 mm Minimum cover to the tension steel Eff.cover d', = 68 mm Eff. Depth, d = 382 mm fck = 30 Mpa fy = 500 Mpa Ec = 27386.1 Mpa Es = 200000 Mpa Depth of N.A., Xu = 144.1 mm Moment, Mw = 126 kNm Working moment x1 = 305.9 mm Distance measured from the elastic neutral axis to the point at which strain 1 is requires Ic = 2090361300 mm 4 MI if the cracked section 1 = 0.00135 - a = 450 mm Distance from compression face to the point at which the crack width is being calculated since max cracking occurs on tension face m = 0.00116 - of the beam, then b = D Distance bet. Bars = 104.666667 mm acr = 75.8 mm Distance from the point under consideration to the surface of the nearest longitudinal bar Wcr = 0.2370 mm Permissible crack width 0.232 mm Cmin Cmin acr acr d N A x b Column numbers C24,C25 Width, b = 450 mm Total depth, D = 450 mm Dia. of bar1 = 16 mm No of bar1 = 3 - Dia. of bar2 = 25 mm No of bar2 = 0 - Ast = 603.2 mm2 Dia. Of stirrups = 8 mm Cover = 50 mm Cover, Cmin = 58 mm Minimum cover to the tension steel Eff.cover d', = 66 mm Eff. Depth, d = 384 mm fck = 30 Mpa fy = 500 Mpa Ec = 27386.1 Mpa Es = 200000 Mpa Depth of N.A., Xu = 54.0 mm Moment, Mw = 20 kNm Working moment x1 = 396.0 mm Distance measured from the elastic neutral axis to the point at which strain 1 is requires Ic = 2123366400 mm 4 MI if the cracked section 1 = 0.00027 - a = 450 mm Distance from compression face to the point at which the crack width is being calculated since max cracking occurs on tension face m = -0.00032 - of the beam, then b = D Distance bet. Bars = 159 mm acr = 95.3 mm Distance from the point under consideration to the surface of the nearest longitudinal bar Wcr = -0.0766 mm Permissible crack width 0.232 mm Cmin Cmin acr acr d N A x b Column numbers SC1, SC2 Width, b = 450 mm Total depth, D = 450 mm Dia. of bar1 = 20 mm No of bar1 = 4 - Dia. of bar2 = 25 mm No of bar2 = 0 - Ast = 1610.0 mm2 Dia. Of stirrups = 8 mm Cover = 50 mm Cover, Cmin = 58 mm Minimum cover to the tension steel Eff.cover d', = 68 mm Eff. Depth, d = 382 mm fck = 30 Mpa fy = 500 Mpa Ec = 27386.1 Mpa Es = 200000 Mpa Depth of N.A., Xu = 144.1 mm Moment, Mw = 121.5 kNm Working moment x1 = 305.9 mm Distance measured from the elastic neutral axis to the point at which strain 1 is requires Ic = 2090361300 mm 4 MI if the cracked section 1 = 0.00130 - a = 450 mm Distance from compression face to the point at which the crack width is being calculated since max cracking occurs on tension face m = 0.00112 - of the beam, then b = D Distance bet. Bars = 104.666667 mm acr = 75.8 mm Distance from the point under consideration to the surface of the nearest longitudinal bar Wcr = 0.2272 mm Permissible crack width 0.232 mm Cmin Cmin acr acr d N A x b Column numbers C6, C7, C12, C23 Width, b = 450 mm Total depth, D = 450 mm Dia. of bar1 = 16 mm No of bar1 = 3 - Dia. of bar2 = 25 mm No of bar2 = 0 - Ast = 603.2 mm2 Dia. Of stirrups = 8 mm Cover = 50 mm Cover, Cmin = 58 mm Minimum cover to the tension steel Eff.cover d', = 66 mm Eff. Depth, d = 384 mm fck = 30 Mpa fy = 500 Mpa Ec = 27386.1 Mpa Es = 200000 Mpa Depth of N.A., Xu = 54.0 mm Moment, Mw = 111 kNm Working moment x1 = 396.0 mm Distance measured from the elastic neutral axis to the point at which strain 1 is requires Ic = 2123366400 mm 4 MI if the cracked section 1 = 0.00151 - a = 450 mm Distance from compression face to the point at which the crack width is being calculated since max cracking occurs on tension face m = 0.00092 - of the beam, then b = D Distance bet. Bars = 159 mm acr = 95.3 mm Distance from the point under consideration to the surface of the nearest longitudinal bar Wcr = 0.2216 mm Permissible crack width 0.232 mm Cmin Cmin acr acr d N A x b