Вы находитесь на странице: 1из 7

Column Numbers

C3, C9, C14, C15, C20, C21


C6, C7, C12, C23
C1, C, C8, C16, C19, C22
Width, b = 450 mm
Total depth, D = 450 mm
Dia. of bar1 = 20 mm
No of bar1 = 4 -
Dia. of bar2 = 25 mm
No of bar2 = 0 -
Ast = 1610.0 mm2
Dia. Of stirrups = 8 mm
Cover = 50 mm
Cover, Cmin = 58 mm Minimum cover to the tension steel
Eff.cover d', = 68 mm
Eff. Depth, d = 382 mm
fck = 30 Mpa
fy = 500 Mpa
Ec = 27386.1 Mpa
Es = 200000 Mpa
Depth of N.A., Xu = 144.1 mm
Moment, Mw = 118 kNm Working moment
x1 = 305.9 mm Distance measured from the elastic neutral axis to the point at which strain 1 is requires
Ic = 2090361300 mm
4
MI if the cracked section
1 = 0.00126 -
a = 450 mm Distance from compression face to the point at which the crack width is being calculated since max cracking occurs on tension face
m = 0.00108 - of the beam, then b = D
Distance bet. Bars = 104.666667 mm
acr = 75.8 mm Distance from the point under consideration to the surface of the nearest longitudinal bar
Wcr = 0.2196 mm
Permissible crack width 0.232 mm
Cmin
Cmin
acr acr
d
N
A
x
b
Column Numbers
C17
C4, C5, C10, C11
Width, b = 450 mm
Total depth, D = 450 mm
Dia. of bar1 = 20 mm
No of bar1 = 5 -
Dia. of bar2 = 25 mm
No of bar2 = 0 -
Ast = 1924.0 mm2
Dia. Of stirrups = 8 mm
Cover = 50 mm
Cover, Cmin = 58 mm Minimum cover to the tension steel
Eff.cover d', = 68 mm
Eff. Depth, d = 382 mm
fck = 30 Mpa
fy = 500 Mpa
Ec = 27386.1 Mpa
Es = 200000 Mpa
Depth of N.A., Xu = 172.2 mm
Moment, Mw = 138 kNm Working moment
x1 = 277.8 mm Distance measured from the elastic neutral axis to the point at which strain 1 is requires
Ic = 2090361300 mm
4
MI if the cracked section
1 = 0.00134 -
a = 450 mm Distance from compression face to the point at which the crack width is being calculated since max cracking occurs on tension face
m = 0.00120 - of the beam, then b = D
Distance bet. Bars = 78.5 mm
acr = 68.5 mm Distance from the point under consideration to the surface of the nearest longitudinal bar
Wcr = 0.2285 mm
Permissible crack width 0.232 mm
Cmin
Cmin
acr acr
d
N
A
x
b
Column numbers
C13
Width, b = 600 mm
Total depth, D = 600 mm
Dia. of bar1 = 32 mm
No of bar1 = 4 -
Dia. of bar2 = 25 mm
No of bar2 = 0 -
Ast = 3217.0 mm2
Dia. Of stirrups = 8 mm
Cover = 50 mm
Cover, Cmin = 58 mm Minimum cover to the tension steel
Eff.cover d', = 74 mm
Eff. Depth, d = 526 mm
fck = 30 Mpa
fy = 500 Mpa
Ec = 27386.1 Mpa
Es = 200000 Mpa
Depth of N.A., Xu = 216.0 mm
Moment, Mw = 271 kNm Working moment
x1 = 384.0 mm Distance measured from the elastic neutral axis to the point at which strain 1 is requires
Ic = 7276578800 mm
4
MI if the cracked section
1 = 0.00104 -
a = 600 mm Distance from compression face to the point at which the crack width is being calculated since max cracking occurs on tension face
m = 0.00090 - of the beam, then b = D
Distance bet. Bars = 150.666667 mm
acr = 89.6 mm Distance from the point under consideration to the surface of the nearest longitudinal bar
Wcr = 0.2070 mm
Permissible crack width 0.232 mm
Cmin
Cmin
acr acr
d
N
A
x
b
Column numbers
C18
Width, b = 450 mm
Total depth, D = 450 mm
Dia. of bar1 = 20 mm
No of bar1 = 4 -
Dia. of bar2 = 25 mm
No of bar2 = 0 -
Ast = 1610.0 mm2
Dia. Of stirrups = 8 mm
Cover = 50 mm
Cover, Cmin = 58 mm Minimum cover to the tension steel
Eff.cover d', = 68 mm
Eff. Depth, d = 382 mm
fck = 30 Mpa
fy = 500 Mpa
Ec = 27386.1 Mpa
Es = 200000 Mpa
Depth of N.A., Xu = 144.1 mm
Moment, Mw = 126 kNm Working moment
x1 = 305.9 mm Distance measured from the elastic neutral axis to the point at which strain 1 is requires
Ic = 2090361300 mm
4
MI if the cracked section
1 = 0.00135 -
a = 450 mm Distance from compression face to the point at which the crack width is being calculated since max cracking occurs on tension face
m = 0.00116 - of the beam, then b = D
Distance bet. Bars = 104.666667 mm
acr = 75.8 mm Distance from the point under consideration to the surface of the nearest longitudinal bar
Wcr = 0.2370 mm
Permissible crack width 0.232 mm
Cmin
Cmin
acr acr
d
N
A
x
b
Column numbers
C24,C25
Width, b = 450 mm
Total depth, D = 450 mm
Dia. of bar1 = 16 mm
No of bar1 = 3 -
Dia. of bar2 = 25 mm
No of bar2 = 0 -
Ast = 603.2 mm2
Dia. Of stirrups = 8 mm
Cover = 50 mm
Cover, Cmin = 58 mm Minimum cover to the tension steel
Eff.cover d', = 66 mm
Eff. Depth, d = 384 mm
fck = 30 Mpa
fy = 500 Mpa
Ec = 27386.1 Mpa
Es = 200000 Mpa
Depth of N.A., Xu = 54.0 mm
Moment, Mw = 20 kNm Working moment
x1 = 396.0 mm Distance measured from the elastic neutral axis to the point at which strain 1 is requires
Ic = 2123366400 mm
4
MI if the cracked section
1 = 0.00027 -
a = 450 mm Distance from compression face to the point at which the crack width is being calculated since max cracking occurs on tension face
m = -0.00032 - of the beam, then b = D
Distance bet. Bars = 159 mm
acr = 95.3 mm Distance from the point under consideration to the surface of the nearest longitudinal bar
Wcr = -0.0766 mm
Permissible crack width 0.232 mm
Cmin
Cmin
acr acr
d
N
A
x
b
Column numbers
SC1, SC2
Width, b = 450 mm
Total depth, D = 450 mm
Dia. of bar1 = 20 mm
No of bar1 = 4 -
Dia. of bar2 = 25 mm
No of bar2 = 0 -
Ast = 1610.0 mm2
Dia. Of stirrups = 8 mm
Cover = 50 mm
Cover, Cmin = 58 mm Minimum cover to the tension steel
Eff.cover d', = 68 mm
Eff. Depth, d = 382 mm
fck = 30 Mpa
fy = 500 Mpa
Ec = 27386.1 Mpa
Es = 200000 Mpa
Depth of N.A., Xu = 144.1 mm
Moment, Mw = 121.5 kNm Working moment
x1 = 305.9 mm Distance measured from the elastic neutral axis to the point at which strain 1 is requires
Ic = 2090361300 mm
4
MI if the cracked section
1 = 0.00130 -
a = 450 mm Distance from compression face to the point at which the crack width is being calculated since max cracking occurs on tension face
m = 0.00112 - of the beam, then b = D
Distance bet. Bars = 104.666667 mm
acr = 75.8 mm Distance from the point under consideration to the surface of the nearest longitudinal bar
Wcr = 0.2272 mm
Permissible crack width 0.232 mm
Cmin
Cmin
acr acr
d
N
A
x
b
Column numbers
C6, C7, C12, C23
Width, b = 450 mm
Total depth, D = 450 mm
Dia. of bar1 = 16 mm
No of bar1 = 3 -
Dia. of bar2 = 25 mm
No of bar2 = 0 -
Ast = 603.2 mm2
Dia. Of stirrups = 8 mm
Cover = 50 mm
Cover, Cmin = 58 mm Minimum cover to the tension steel
Eff.cover d', = 66 mm
Eff. Depth, d = 384 mm
fck = 30 Mpa
fy = 500 Mpa
Ec = 27386.1 Mpa
Es = 200000 Mpa
Depth of N.A., Xu = 54.0 mm
Moment, Mw = 111 kNm Working moment
x1 = 396.0 mm Distance measured from the elastic neutral axis to the point at which strain 1 is requires
Ic = 2123366400 mm
4
MI if the cracked section
1 = 0.00151 -
a = 450 mm Distance from compression face to the point at which the crack width is being calculated since max cracking occurs on tension face
m = 0.00092 - of the beam, then b = D
Distance bet. Bars = 159 mm
acr = 95.3 mm Distance from the point under consideration to the surface of the nearest longitudinal bar
Wcr = 0.2216 mm
Permissible crack width 0.232 mm
Cmin
Cmin
acr acr
d
N
A
x
b

Вам также может понравиться