Вы находитесь на странице: 1из 4

M/S KRIBHCO SHYM FERTILIZE LTD.

SHAHJAHANPUR UP - INDIA
10 LP STEAM (IMPORT/EXPORT)
LINE FROM UREA PLANT TO
AMMONIA PLANT

TITLE : FLEXIBILITY ANALYSIS REPORT
Doc. No. 10 LP STEAM
Rev-0



CLIENT : M/S KRIBHCO SHYAM FERTILIZER LTD.
SHAHJAHANPUR UP- INDIA

PROJECT. : 10 LP STEAM (IMPORT/EXPORT) LINE FROM UREA
PLANT TO AMMONIA PLANT.

CONSULTANT : A.B.CONSULTANTS

CLIENT REF. NO. : KSFL/SPN/PUR/RP-130147/1300136 August 20, 2013


SERVICE : LP STEAM (IBR).

SYSTEM NO. : FLEXIBILITY ANALYSIS FOR 10 LP STEAM LINE
(IMPORT / EXPOERT ) FROM UREA PLANT TO
AMMONIA PLANT

























1 09.11.13
REVISED CV & FT
DIMENSIONS
AK KK SS
0 15.10.13 ISSUED FOR ENGINEERING
A 06.09.13 ISSUED FOR CLIENT REVIEW
Rev. Description
Prepared
By
Checked
By
Reviewed
By


M/S KRIBHCO SHYM FERTILIZE LTD.
SHAHJAHANPUR UP - INDIA
10 LP STEAM (IMPORT/EXPORT)
LINE FROM UREA PLANT TO
AMMONIA PLANT

TITLE : FLEXIBILITY ANALYSIS REPORT
Doc. No. 10 LP STEAM
Rev-0

CONTENTS
Sl. No. Description
1. Check list for piping flexibility analysis
2. Basis of Flexibility Analysis.
3. Conclusion of Stress Analysis Reports.
4. Attachments.
4.1 Caesar Analysis Reports.
4.2 Caesar Input Soft Copy (on CD).

























M/S KRIBHCO SHYM FERTILIZE LTD.
SHAHJAHANPUR UP - INDIA
10 LP STEAM (IMPORT/EXPORT)
LINE FROM UREA PLANT TO
AMMONIA PLANT

TITLE : FLEXIBILITY ANALYSIS REPORT
Doc. No. 10 LP STEAM
Rev-0

1. CHECK LIST FOR PIPING FLEXIBILITY ANALYSIS
Following points are specifically checked and confirmations are marked against each
point :

Sl.
No.

Comments

Confirmation
Remarks
(Clarification)
1
Maximum spacing of supports and guides in hot as well as
cold condition conditions are within bid specified values
Yes
2
All resting supports are acting in all cases Yes
3
Maximum load acting on various supports are checked
and well with in the limit.
Yes
4
Design and Operating pressure & temperature is taken
from P & ids.
Yes
5
Input data strictly matches with the isometric system
attached with the report
Yes
6
There is no fouling of expanded pipe with adjoining pipe
in hot as well as in cold condition
Yes
7
Loads on restraints at Hydrostatic test condition also have
been taken care of in design of the supports
Yes

M/S KRIBHCO SHYM FERTILIZE LTD.
SHAHJAHANPUR UP - INDIA
10 LP STEAM (IMPORT/EXPORT)
LINE FROM UREA PLANT TO
AMMONIA PLANT

TITLE : FLEXIBILITY ANALYSIS REPORT
Doc. No. 10 LP STEAM
Rev-0


2. BASIS FOR STATIC ANALYSIS
The followings are basis for static analysis
2.1 This system consists of the following lines
SL.NO. LINE NO
2.1.1 10-SL-000.00-B22S-IH
2.2 The transverse deflection will be limited to 25 mm in general.
2.3 The number of thermal load cycles is considered to be 7000.
2.4 For supports, default stiffness of CAESAR II will be used, if not, otherwise
mentioned.
2.5 Insulation density of mineral wool is taken as 140 kg/m.

3. CONCLUSION.
The maximum forces & moments due to Design / Operating & hydro-test conditions
at various supports are well with in the allowable limits.
Report enclosed.
The maximum (Thermal & Sustained) stresses due to Design / Operating &
Hydro-test conditions are well with in allowable code stress limits (Allowable stress
as per code ASTM B 31.3) in the System.
Report enclosed.