ABOUT US : Taiba Engineering Consultants' (TEC) is an organization having rich expertise in training fresh & practicing Engineers

to become Design Engineer and non-engineers to become MEP Draughtsmen in HVAC, Electrical, Plumbing, Fire-fighting &
Green Building Designing & Draughting in the field of Building Services. We provide a career based training program which aims to
develop quality MEP professionals. The course is designed to bridge the gap between academics and industry. The training program
aims to harness your skills and enhance your chances for a successful career with HVAC, Electrical, Plumbing, Fire-Fighting, Green
Building Designing & Draughting and Green Building Energy Simulation training.
Construction industry is booming and is at its zenith. There is a consistent increase in the demand for Engineering Professionals who are
expert in MEP (Mechanical, Electrical, Plumbing)Services. With the changing trends in the construction industry where sky high
buildings with innovative and challenging designs are being built, it becomes hard for any engineer fresh out of college, to be start a
career without proper training in the advanced techniques being used in Industry for Designing these ultra modern buildings. We at
TEC help to bridge the gap between academics and the real professional world. We train our students with the most advanced tools to
make them expert to face the contemporary technological challenges in building industry.
Benefits : These are 100% job oriented courses to join industry as trained professional to handle any project from day one. These
courses can also be done as Major Project by B.E., B.Tech., M.Tech. students to be industry ready when they comes out of colleges. It
provides you with the process specific domain skills, which is not covered in the syllabus of any University or Technical Education Board.
Lack of these skills renders 90% of APs technical graduates unemployable [as per GO RT No.499(July, 2010) and NASSCOM
- Deccan Chronicle - 13th Oct.2010].
Faculty : Mr. Syed Moazzam Ali, M.Tech., having 14 years of Middle East experience in MEP field, who
have formerly worked as a faculty in engineering College, and worked as Project Leader and Manager
with a MNC at Hyderabad. He holds lifetime membership of ISHRAE - (Indian Society of Heating,
Refrigeration and Air Conditioning Engineers), FSAI (Fire & Security Association of India) and is a
certified IGBC-AP [Indian Green Building Council - Accredited Professional].
He is currently pursuing Ph.D. in HVAC from JNT University and handles projects which TEC undertakes
from India and abroad as Chief MEP & Green Building Consultant, to impart professional training.
He has also conduct corporate training seminars for various construction and consulting companies
designing professionals at Mumbai and Bangalore besides Hyderabad.
Placement Assistance : We follow ASHRAE & SMACNA, NEC (National Electrical Code), BS, DEWA, ADEWA, IEC NEMA, NFPA
NBC standards which led us to become authorised man-power vendors (campus selection and placement assistance) for providing
suitable candidates in the field of engineering to various well known companies, like M/s. Altech Star Solutions Pvt. Ltd. Chennai,
for ETA - Dubai, M/s.Voltas-IOBG (International Operations Business Group)-Dubai & APEX Knowledge Technologies Pvt. Ltd. etc.
OUR COURSES :
Designing & Drafting of
aHVAC (Heating, Ventilation and Air-Conditioning)
aElectrical
aPlumbing
aFire Fighting
aRevit MEP
aGreen Building Energy Simulation
aIGBC-AP Exam training
For Whom ?
Mechanical, EEE, ECE, EIT Engineers to become Design Engineer
Diploma holders and non-Engineers to become MEP Draughtsmen
Scope :
Wherever construction activity is on, there is a need for trained and qualified Design Engineers and Draughtsmen.
I
S
H
R
A
E
FSAI
Fire & Security
Association of India.
MEMBER
Page 3 Page 2
HVAC (Heating, Ventilating & Air-Conditioning) Designing & Draughting
lIntroduction to HVAC Systems, Psychometric Chart, DBT, WBT, RH,
Sensible and Latent Heat, Dew point temperature, Humidity Ratio etc.
lVentilation , Infiltration [ ACH / CRACK Method].
lHeat load Calculation (Manually by E-20 and General) and by software
programs like: Carrier - HAP (Hourly Analysis Program), Elite, General.
lTypes of Duct, Selection of Materials of Duct, Classification of Ducts
[Low, Medium & High Pressure], Duct Gauge Selection, Comparison
between Different Shapes of Duct, Duct Fabrication Procedure.
lDuct Designing using : a) formulae [Static Regain, Equal Friction,
Velocity Reduction] (b) using Ductulators and (c) using software
programs (DUCTO, McQuay, Duct Checker).
lAir terminal selection using BETA performance data program.
lVapour Absorption Machine [VAM] System.
lChilled Water Pipe Sizing McQuay Pipe Sizing Software.
lCar Parking Ventilation Impulse & Induction.
lKitchen Ventilation Hood Designing.
lE.S.P [External Static Pressure] Calculation for Blower Selection.
lFan & Pump Laws. Open Loop & Closed Loop System.
lHydraulic Calculation for Chilled water Pump Selection.
lPrimary, Secondary Pump Selection, Pumps in Series & Parallel .
lCommon Header Pipe sizing.
lStair Well Pressurization System Designing.
lEstimation & Costing.
lDistrict Cooling System.
lGreen in HVAC System Designing Energy Modeling .
lVRV System designing, VRV Pipe Sizing using 'Toshiba VRV' software.
lRefrigerant Pipe Sizing DX System.
lVulcan Lockring.
lDe-Humidifier Selection.
lExhaust Fan Selection Performance curve, Desert Cooler Selection.
lASHRAE 62.1, ASHRAE 90.1 & SMACNA Standards.
lCoil Selection - Software.
lExpansion Tank Selection - Software.
lCooling Tower Selection Evaporative Losses calculation.
lEquipments Selection - Package A/c, Chiller, AHU, FCU etc, Zamil
software.
lWinter Load Calculation, Heater, Radiator, Convector & Boiler selection.
lCooling without Air-Conditioning & Passive Cooling System designing.
lEnergy Conservation Measures: Under Floor Cooling, Radiant
cooling, Geothermal Cooling, Thermal cooling or Ice on Pipe
system, HRW - Heat Recovery wheel, EAT - Earth Air Tunnel system.
lCold Store Designing.
lHVAC Design Drawing & Shop Drawing Preparation: Representation
of Air-conditioning & Ventilation Ducts, Chilled Water pipes, Duct
fittings - Elbow, TEE, WYE. Dampers - Volume Control Dampers
[VCD], Splitter Dampers [SD], Smoke Dampers, Fire Dampers etc.
and Duct supports. Representation of Duct/Pipe levels, slope, flow
directions, BOD's, BOP's FCU's, AHU's, Chillers, Pumps, Valves -
Isolating, Regulating, NRV, Strainer etc. Representation of section
Drawings.