Академический Документы
Профессиональный Документы
Культура Документы
TESI
Code 001G1201
CONSTRUCTION FEATURES
TESI radiators are made of 25 mm diameter and 1.20 mm thick steel tube
The manifolds are made from 1.50 mm thick sheet steel and have a 25 mm radius of curvature.
1
They have 1 /4 BSP connections with right and left-hand thread and self-centering adjustable ring nuts.
It is important to remember that TESI radiators of the same height can be nippled together with a
minimum of two sections.
TEST FEATURES
Each TESI radiator is air pressure tested to 1,3 time the maximum allowed working pressure.
WORKING REQUIREMENTS
Do not connect TESI to the domestic water supply.
The maximum allowed working pressure is 12 bar for TESI 2, 3 and 4, 10 bar for TESI 5 and 6.
The maximum working temperature is 95C.
Flow resistance is negligible in comparison to the other system components.
HEAT OUTPUT
The heat output of TESI radiators is determined using tests in accordance with UNI EN442.
Measurements carried out on white epoxy powder painted models, at the Thermotechnical Research
and Measurement Laboratory of Milan Polytechnic. Report ENE/MRT.RES.01003_A. Report
ENE/MRT.ITPL.01004.
Report
ENE/MRT.ITPL.01003_B.
Report
ENE/MRT.ITPL.01005.
Report
ENE/MRT.RES.01003_C.
COLOURS
The STANDARD version of TESI radiators are painted with WHITE RAL 9010 epoxy powder; they are also
available on request in the vast Serie COLOR colour range.
TESI
Page 2
TESI
Standard models
H` 0.5
H2
33.5 0.5
R 25 0.2
A
+0.1
45 -0.5
65 +0.5
-0.1
1
A: G 1 /4 threading
Model
Depth
Section
[mm]
65
65
65
65
65
65
65
65
65
65
65
65
elemento
[mm]
45
45
45
45
45
45
45
45
45
45
45
45
Code
RT20200
RT20300
RT20400
RT20500
RT20600
RT20750
RT20900
RT21000
RT21500
RT21800
RT22000
RT22500
Dimensional tolerances:
mm
mm
mm
mm
Rated thermal power (Qn)
TESI
Height Conn.centres
H
[mm]
200
302
402
502
602
752
902
1002
1502
1802
2002
2502
+0,5
+0,1
+2,0
+0,5
H'
[mm]
133
235
335
435
535
685
835
935
1435
1735
1935
2435
-0,5
-0,5
-2,0
-0,5
Weight
Capacit
y
[Kg]
0,35
0,49
0,63
0,78
0,92
1,13
1,34
1,48
2,18
2,61
2,89
3,59
[lt]
0,30
0,38
0,46
0,54
0,62
0,74
0,86
0,94
1,34
1,59
1,75
2,15
Qn at
Calculation Exponent
EN442(t=50C)
[Watt]
14,9
23,4
30,1
36,7
43,2
52,9
62,7
69,2
103,0
124,3
139,0
177,8
for t 50C
Q=Qn*(Dt/50)^n
1,25221
1,23859
1,24656
1,25453
1,26250
1,27445
1,28640
1,29404
1,33221
1,32939
1,31894
1,29280
Depth
Element length
Height
Connection centre
Calculated according to UNI EN442. Measurements carried out
on white epoxy powder painted models, at the Thermotechnical
Research and Measurement Laboratory of Milan Polytechnic.
Report ENE/MRT.RES.01003_A
Page 3
TESI
Sec. Length
[mm] (*)
THERMAL HEAD
Standard models
Watt
50
Mod.
200
Mod.
300
Mod.
400
Mod.
500
Mod.
600
Mod.
750
Mod.
900
Mod.
1000
Mod.
1500
Mod.
1800
Mod.
2000
Mod.
2500
1
2
3
4
5
45
90
135
180
225
15
30
45
60
75
23
47
70
94
117
30
60
90
120
151
37
73
110
147
183
43
86
129
173
216
53
106
159
212
264
63
125
188
251
313
69
138
208
277
346
103
206
309
412
515
124
249
373
497
621
139
278
417
556
695
178
356
533
711
889
6
7
8
9
10
270
315
360
405
450
89
104
119
134
149
141
164
188
211
234
181
211
241
271
301
220
257
293
330
367
259
302
345
388
432
317
370
423
476
529
376
439
501
564
627
415
485
554
623
692
618
721
824
927
1030
746
870
994
1119
1243
834
973
1112
1251
1390
1067
1245
1422
1600
1778
11
12
13
14
15
495
540
585
630
675
164
179
194
209
224
258
281
305
328
352
331
361
391
421
452
403
440
476
513
550
475
518
561
604
647
582
635
687
740
793
689
752
815
877
940
761
831
900
969
1038
1133
1236
1339
1442
1545
1367
1491
1616
1740
1864
1529
1668
1807
1946
2085
1956
2133
2311
2489
2667
16
17
18
19
20
720
765
810
855
900
239
253
268
283
298
375
398
422
445
469
482
512
542
572
602
586
623
660
696
733
690
734
777
820
863
846
899
952
1005
1058
1003
1065
1128
1191
1253
1108
1177
1246
1315
1384
1648
1751
1854
1957
2060
1989
2113
2237
2362
2486
2224
2363
2502
2641
2780
2845
3022
3200
3378
3556
21
22
23
24
25
945
990
1035
1080
1125
313
328
343
358
373
492
516
539
563
586
632
662
692
722
753
770
806
843
880
916
906
949
992
1036
1079
1110
1163
1216
1269
1322
1316
1379
1441
1504
1567
1454
1523
1592
1661
1731
2163
2266
2369
2472
2575
2610
2734
2859
2983
3107
2919
3058
3197
3336
3475
3734
3911
4089
4267
4445
26
27
28
29
30
1170
1215
1260
1305
1350
388
403
417
432
447
609
633
656
680
703
783
813
843
873
903
953
990
1026
1063
1100
1122
1165
1208
1251
1295
1375
1428
1481
1534
1586
1629
1692
1754
1817
1880
1800
1869
1938
2007
2077
2678
2781
2884
2987
3090
3232
3356
3480
3604
3729
3614
3753
3892
4031
4170
4623
4800
4978
5156
5334
31
32
33
34
1395
1440
1485
1530
462
477
492
507
727
750
774
797
933
963
993
1023
1136
1173
1209
1246
1338
1381
1424
1467
1639
1692
1745
1798
1942
2005
2068
2130
2146
2215
2284
2353
3193
3296
3399
3502
3853
3977
4102
4226
4309
4448
4587
4726
5511
5689
5867
6045
35
36
37
38
39
40
1575
1620
1665
1710
1755
1800
522
537
552
567
581
596
820
844
867
891
914
938
1054
1084
1114
1144
1174
1204
1283
1319
1356
1393
1429
1466
1510
1553
1597
1640
1683
1726
1851
1904
1957
2009
2062
2115
2193
2256
2318
2381
2444
2506
2423
2492
2561
2630
2700
2769
3605
3708
3811
3914
4017
4120
4350
4474
4599
4723
4847
4972
4865
5004
5143
5282
5421
5560
6223
6400
6578
6756
6934
7112
(*)
TESI
Add 24 mm overall clearance to the total length of the battery for the 1 /4" manifold plug.
To express the thermal output in Kcal/h multiply the value by 0,860 (1 Watt = 0,860 Kcal/h)
Page 4
TESI
Standard models
H` 0.5
H2
33.5 0.5
R25 0.2
A
+0.1
45 -0.5
+0.5
101 -0.1
1
A: G 1 /4 threading
Model
Code
RT30200
RT30300
RT30400
RT30500
RT30600
RT30750
RT30900
RT31000
RT31500
RT31800
RT32000
RT32500
Depth
[mm]
101
101
101
101
101
101
101
101
101
101
101
101
Section
Length
[mm]
45
45
45
45
45
45
45
45
45
45
45
45
Dimensional tolerances mm
mm
mm
mm
Rated thermal power (Qn)
TESI
-0,1
-0,5
-2,0
-0,5
Weight
Capacity
[Kg]
0,51
0,73
0,94
1,15
1,36
1,68
1,99
2,20
3,26
3,89
4,32
5,37
[lt]
0,40
0,52
0,64
0,76
0,88
1,06
1,24
1,37
1,97
2,33
2,57
3,17
Qn at
Calculation Exponent
EN442(t=50C)
for t 50C
[Watt]
Q=Qn*(Dt/50)^n
20,3
1,28832
32,5
1,24809
42,0
1,25905
51,4
1,27000
60,6
1,28095
74,3
1,29739
87,8
1,31382
96,8
1,31651
141,7
1,32995
168,9
1,32520
187,2
1,31777
233,7
1,29918
Depth
Element length
Height
Connection centre
Calculated according to UNI EN442. Measurements carried out
on white epoxy powder painted models, at the Thermotechnical
Research and Measurement Laboratory of Milan Polytechnic.
Report ENE/MRT.ITPL.01004
Page 5
TESI
Sec.
THERMAL HEAD
50
Standard models
Watt
1
2
3
4
5
Length
[mm] (*)
45
90
135
180
225
Mod.
200
20
41
61
81
101
Mod.
300
33
65
98
130
163
Mod.
400
42
84
126
168
210
Mod.
500
51
103
154
205
257
Mod.
600
61
121
182
242
303
Mod.
750
74
149
223
297
371
Mod.
900
88
176
263
351
439
Mod.
1000
97
194
290
387
484
Mod.
1500
142
283
425
567
709
Mod.
1800
169
338
507
676
845
Mod.
2000
187
374
562
749
936
Mod.
2500
234
467
701
935
1169
6
7
8
9
10
270
315
360
405
450
122
142
162
183
203
195
228
260
293
325
252
294
336
378
420
308
360
411
462
514
363
424
485
545
606
446
520
594
668
743
527
615
702
790
878
581
678
774
871
968
850
992
1134
1276
1417
1014
1182
1351
1520
1689
1123
1310
1498
1685
1872
1402
1636
1870
2103
2337
11
12
13
14
15
495
540
585
630
675
223
243
264
284
304
358
390
423
455
488
462
504
546
588
630
565
616
668
719
771
666
727
788
848
909
817
891
965
1040
1114
966
1054
1141
1229
1317
1065
1161
1258
1355
1452
1559
1701
1843
1984
2126
1858
2027
2196
2365
2534
2059
2247
2434
2621
2808
2571
2805
3038
3272
3506
16
17
18
19
20
720
765
810
855
900
325
345
365
386
406
520
553
585
618
650
672
715
757
799
841
822
873
925
976
1027
969
1030
1090
1151
1212
1188
1262
1337
1411
1485
1405
1493
1580
1668
1756
1549
1645
1742
1839
1936
2268
2410
2551
2693
2835
2703
2872
3041
3209
3378
2995
3183
3370
3557
3744
3740
3973
4207
4441
4674
21
22
23
24
25
945
990
1035
1080
1125
426
446
467
487
507
683
715
748
780
813
883
925
967
1009
1051
1079
1130
1182
1233
1284
1272
1333
1393
1454
1515
1559
1634
1708
1782
1856
1844
1932
2019
2107
2195
2033
2129
2226
2323
2420
2977
3118
3260
3402
3544
3547
3716
3885
4054
4223
3931
4119
4306
4493
4680
4908
5142
5376
5609
5843
26
27
28
29
30
1170
1215
1260
1305
1350
528
548
568
588
609
845
878
910
943
975
1093
1135
1177
1219
1261
1336
1387
1438
1490
1541
1575
1636
1696
1757
1817
1931
2005
2079
2153
2228
2283
2371
2458
2546
2634
2517
2613
2710
2807
2904
3685
3827
3969
4110
4252
4392
4561
4730
4899
5068
4867
5055
5242
5429
5616
6077
6310
6544
6778
7012
31
32
33
34
35
1395
1440
1485
1530
1575
629
649
670
690
710
1008
1040
1073
1105
1138
1303
1345
1387
1429
1471
1592
1644
1695
1747
1798
1878
1939
1999
2060
2120
2302
2376
2450
2525
2599
2722
2810
2897
2985
3073
3000
3097
3194
3291
3388
4394
4536
4677
4819
4961
5237
5405
5574
5743
5912
5804
5991
6178
6365
6552
7245
7479
7713
7946
8180
36
37
38
39
40
1620
1665
1710
1755
1800
730
751
771
791
812
1170
1203
1235
1268
1300
1513
1555
1597
1639
1681
1849
1901
1952
2003
2055
2181
2241
2302
2363
2423
2673
2747
2822
2896
2970
3161
3249
3336
3424
3512
3484
3581
3678
3775
3872
5103
5244
5386
5528
5670
6081
6250
6419
6588
6757
6740
6927
7114
7301
7488
8414
8648
8881
9115
9349
(*)
TESI
Add 24 mm overall clearance to the total length of the battery for the 1 /4" manifold plug.
To express the thermal output in Kcal/h multiply the value by 0,860 (1 Watt = 0,860 Kcal/h)
Page 6
TESI
Special models:
Cast iron and aluminium
connection centre
H` 0.5
H2
33.5 0.5
R25 0.2
A
+0.1
45 -0.5
+0.5
101 -0.1
A: G 1 /4 threading
Model
Code
RT30565
RT30665
RT30685
RT30765
RT30865
RT30885
Depth
[mm]
101
101
101
101
101
101
Section
Length
[mm]
45
45
45
45
45
45
Dimensional tolerances mm
mm
mm
mm
Rated thermal power (Qn)
TESI
-0,1
-0,5
-2,0
-0,5
Weight
Capacity
[Kg]
1,29
1,50
1,54
1,71
1,92
1,96
[lt]
0,84
0,96
0,99
1,08
1,20
1,23
Qn at
Calculation Exponent
EN442(t=50C)
for t 50C
[Watt]
Q=Qn*(Dt/50)^n
57,4
1,27712
66,5
1,28808
68,3
1,29027
75,6
1,29903
84,6
1,30998
86,4
1,31218
Depth
Element length
Height
Connection centre
Calculated according to UNI EN442. Measurements carried out
on white epoxy powder painted models, at the Thermotechnical
Research and Measurement Laboratory of Milan Polytechnic.
Report ENE/MRT.ITPL.01004
Page 7
TESI
3
Sec.
(*)
TESI
THERMAL HEAD
Special models
Cast iron and aluminium
connection centre
Watt
50
1
2
3
4
5
Length
[mm] (*)
45
90
135
180
225
Mod.
565
57
115
172
229
287
Mod.
665
67
133
200
266
333
Mod.
685
68
137
205
273
342
Mod.
765
76
151
227
302
378
Mod.
865
85
169
254
339
423
Mod.
885
86
173
259
346
432
6
7
8
9
10
270
315
360
405
450
344
402
459
516
574
399
466
532
599
665
410
478
547
615
683
454
529
605
680
756
508
592
677
762
846
519
605
692
778
864
11
12
13
14
15
495
540
585
630
675
631
688
746
803
861
732
798
865
931
998
752
820
888
957
1025
832
907
983
1058
1134
931
1016
1100
1185
1270
951
1037
1124
1210
1297
16
17
18
19
20
720
765
810
855
900
918
975
1033
1090
1147
1064
1131
1197
1264
1330
1093
1162
1230
1298
1367
1210
1285
1361
1436
1512
1354
1439
1524
1608
1693
1383
1469
1556
1642
1729
21
22
23
24
25
945
990
1035
1080
1125
1205
1262
1320
1377
1434
1397
1463
1530
1596
1663
1435
1503
1572
1640
1709
1588
1663
1739
1814
1890
1777
1862
1947
2031
2116
1815
1902
1988
2075
2161
26
27
28
29
30
1170
1215
1260
1305
1350
1492
1549
1606
1664
1721
1730
1796
1863
1929
1996
1777
1845
1914
1982
2050
1966
2041
2117
2192
2268
2201
2285
2370
2455
2539
2247
2334
2420
2507
2593
31
32
33
34
35
1395
1440
1485
1530
1575
1778
1836
1893
1951
2008
2062
2129
2195
2262
2328
2119
2187
2255
2324
2392
2344
2419
2495
2570
2646
2624
2708
2793
2878
2962
2680
2766
2853
2939
3025
36
37
38
39
40
1620
1665
1710
1755
1800
2065
2123
2180
2237
2295
2395
2461
2528
2594
2661
2460
2529
2597
2665
2734
2722
2797
2873
2948
3024
3047
3132
3216
3301
3386
3112
3198
3285
3371
3458
Add 24 mm overall clearance to the total length of the battery for the 1 /4" manifold plug.
To express the thermal output in Kcal/h multiply the value by 0,860 (1 Watt = 0,860 Kcal/h)
Page 8
TESI
Standard models
H2
H` 0.5
33.5 0.5
R25 0.2
A
+0.5
45 -0.1
+0.5
139 -0.1
1
A: G 1 /4 threading
Model
Code
RT40200
RT40300
RT40400
RT40500
RT40600
RT40750
RT40900
RT41000
RT41500
RT41800
RT42000
RT42500
Depth
[mm]
139
139
139
139
139
139
139
139
139
139
139
139
Section
length
[mm]
45
45
45
45
45
45
45
45
45
45
45
45
Dimensional tolerances mm
mm
mm
mm
Rated thermal power (Qn)
TESI
-0,1
-0,5
-2,0
-0,5
Weight
Capacity
[Kg]
0,70
0,99
1,27
1,55
1,83
2,25
2,68
2,96
4,37
5,21
5,77
7,18
[lt]
0,55
0,71
0,87
1,03
1,20
1,44
1,68
1,84
2,64
3,12
3,44
4,24
Qn at
EN442(t=50C)
[Watt]
26,0
42,1
54,6
66,9
79,0
96,8
114,3
125,9
182,6
216,0
238,1
292,8
Calculation Exponent
for t 50C
Q=Qn*(Dt/50)^n
1,32643
1,25812
1,27223
1,28633
1,30044
1,32160
1,34276
1,34023
1,32755
1,32078
1,31653
1,30592
Depth
Element length
Height
Connection centre
Calculated according to UNI EN442. Measurements carried out
on white epoxy powder painted models, at the Thermotechnical
Research and Measurement Laboratory of Milan Polytechnic.
Report ENE/MRT.RES.01003_B
Page 9
TESI
Sec. Length
[mm] (*)
1
45
2
90
3
135
4
180
5
225
THERMAL HEAD
50
Standard models
Watt
Mod.
200
26
52
78
104
130
Mod.
300
42
84
126
168
210
Mod.
400
55
109
164
218
273
Mod.
500
67
134
201
268
335
Mod.
600
79
158
237
316
395
Mod.
750
97
194
290
387
484
Mod.
900
114
229
343
457
572
Mod.
1000
126
252
378
504
630
Mod.
1500
183
365
548
731
913
Mod.
1800
216
432
648
864
1080
Mod.
2000
238
476
714
952
1191
Mod.
2500
293
586
878
1171
1464
6
7
8
9
10
270
315
360
405
450
156
182
208
234
260
252
295
337
379
421
328
382
437
492
546
401
468
535
602
669
474
553
632
711
790
581
678
774
871
968
686
800
915
1029
1143
755
881
1007
1133
1259
1096
1278
1461
1644
1826
1296
1512
1728
1944
2160
1429
1667
1905
2143
2381
1757
2049
2342
2635
2928
11
12
13
14
15
495
540
585
630
675
286
312
338
364
390
463
505
547
589
631
601
655
710
765
819
736
803
870
937
1004
869
948
1027
1106
1185
1065
1161
1258
1355
1452
1258
1372
1486
1601
1715
1385
1511
1637
1763
1889
2009
2192
2374
2557
2739
2376
2592
2808
3024
3240
2619
2857
3095
3333
3572
3220
3513
3806
4099
4391
16
17
18
19
20
720
765
810
855
900
416
442
468
494
520
673
715
757
800
842
874
929
983
1038
1092
1070
1137
1204
1271
1338
1264
1343
1422
1501
1580
1549
1645
1742
1839
1936
1829
1944
2058
2172
2287
2014
2140
2266
2392
2518
2922
3105
3287
3470
3653
3456
3673
3889
4105
4321
3810
4048
4286
4524
4762
4684
4977
5270
5562
5855
21
22
23
24
25
945
990
1035
1080
1125
546
572
598
624
650
884
926
968
1010
1052
1147
1202
1256
1311
1366
1405
1472
1539
1606
1673
1659
1738
1817
1896
1975
2033
2129
2226
2323
2420
2401
2515
2630
2744
2858
2644
2770
2896
3022
3148
3835
4018
4200
4383
4566
4537
4753
4969
5185
5401
5000
5238
5476
5714
5953
6148
6441
6733
7026
7319
26
27
28
29
30
1170
1215
1260
1305
1350
675
701
727
753
779
1094
1136
1178
1220
1262
1420
1475
1529
1584
1639
1739
1806
1873
1940
2007
2053
2132
2211
2290
2369
2517
2613
2710
2807
2904
2973
3087
3201
3316
3430
3273
3399
3525
3651
3777
4748
4931
5114
5296
5479
5617
5833
6049
6265
6481
6191
6429
6667
6905
7143
7612
7905
8197
8490
8783
31
32
33
34
35
1395
1440
1485
1530
1575
805
831
857
883
909
1304
1347
1389
1431
1473
1693
1748
1802
1857
1912
2074
2141
2208
2275
2342
2448
2527
2606
2685
2764
3000
3097
3194
3291
3388
3544
3659
3773
3887
4002
3903
4029
4155
4281
4407
5662
5844
6027
6209
6392
6697
6913
7129
7345
7561
7381
7619
7857
8095
8334
9076
9368
9661
9954
10247
36
37
38
39
40
1620
1665
1710
1755
1800
935
961
987
1013
1039
1515
1557
1599
1641
1683
1966
2021
2076
2130
2185
2408
2475
2542
2609
2676
2843
2922
3001
3080
3159
3484
3581
3678
3775
3872
4116
4230
4345
4459
4573
4532
4658
4784
4910
5036
6575
6757
6940
7123
7305
7777
7993
8209
8425
8641
8572
8810
9048
9286
9524
10539
10832
11125
11418
11710
(*)
TESI
Add 24 mm overall clearance to the total length of the battery for the 1 /4" manifold plug.
To express the thermal output in Kcal/h multiply the value by 0,860 (1 Watt = 0,860 Kcal/h)
Page 10
TESI
Special models:
Cast iron and aluminium
connection centre
H2
H` 0.5
33.5 0.5
R25 0.2
A
+0.5
45 -0.1
+0.5
139 -0.1
A: G 1 /4 threading
Model
Code
RT40565
RT40665
RT40685
RT40765
RT40865
RT40885
Depth
[mm]
139
139
139
139
139
139
Dimensional tolerances mm
mm
mm
mm
Rated thermal power (Qn)
TESI
+0,5
+0,1
+2,0
+0,5
-0,1
-0,5
-2,0
-0,5
Weight
Capacity
[Kg]
1,73
2,02
2,07
2,30
2,58
2,63
[lt]
1,14
1,30
1,33
1,46
1,62
1,65
Qn at
EN442(t=50C)
[Watt]
74,8
86,7
89,1
98,6
110,3
112,6
Calculation Exponent
for t 50C
Q=Qn*(Dt/50)^n
1,29550
1,30961
1,31243
1,32372
1,33782
1,34064
Depth
Element length
Height
Connection centre
Calculated according to UNI EN442. Measurements carried out
on white epoxy powder painted models, at the Thermotechnical
Research and Measurement Laboratory of Milan Polytechnic.
Report ENE/MRT.RES.01003_B
Page 11
TESI
4
Sec.
(*)
TESI
THERMAL HEAD
Special models
Cast iron and aluminium
connection centre
50
Watt
1
2
3
4
5
Length
[mm] (*)
45
90
135
180
225
Mod.
565
75
150
224
299
374
Mod.
665
87
173
260
347
434
Mod.
685
89
178
267
356
446
Mod.
765
99
197
296
394
493
Mod.
865
110
221
331
441
551
Mod.
885
113
225
338
450
563
6
7
8
9
10
270
315
360
405
450
449
523
598
673
748
520
607
694
781
867
535
624
713
802
891
591
690
788
887
986
662
772
882
992
1103
676
788
901
1013
1126
11
12
13
14
15
495
540
585
630
675
822
897
972
1047
1122
954
1041
1128
1214
1301
980
1069
1158
1248
1337
1084
1183
1281
1380
1478
1213
1323
1433
1544
1654
1238
1351
1464
1576
1689
16
17
18
19
20
720
765
810
855
900
1196
1271
1346
1421
1495
1388
1475
1561
1648
1735
1426
1515
1604
1693
1782
1577
1676
1774
1873
1971
1764
1874
1985
2095
2205
1801
1914
2027
2139
2252
21
22
23
24
25
945
990
1035
1080
1125
1570
1645
1720
1794
1869
1822
1908
1995
2082
2169
1871
1960
2050
2139
2228
2070
2168
2267
2365
2464
2315
2426
2536
2646
2757
2364
2477
2590
2702
2815
26
27
28
29
30
1170
1215
1260
1305
1350
1944
2019
2094
2168
2243
2255
2342
2429
2515
2602
2317
2406
2495
2584
2673
2563
2661
2760
2858
2957
2867
2977
3087
3198
3308
2927
3040
3153
3265
3378
31
32
33
34
35
1395
1440
1485
1530
1575
2318
2393
2467
2542
2617
2689
2776
2862
2949
3036
2762
2852
2941
3030
3119
3055
3154
3252
3351
3450
3418
3528
3639
3749
3859
3490
3603
3715
3828
3941
36
37
38
39
40
1620
1665
1710
1755
1800
2692
2766
2841
2916
2991
3123
3209
3296
3383
3470
3208
3297
3386
3475
3564
3548
3647
3745
3844
3942
3969
4080
4190
4300
4410
4053
4166
4278
4391
4504
Add 24 mm overall clearance to the total length of the battery for the 1 /4" manifold plug.
To express the thermal output in Kcal/h multiply the value by 0,860 (1 Watt = 0,860 Kcal/h)
Page 12
R25 0.2
H2
H` 0.5
33.5 0.5
TESI
Standard models
A
+0.5
45 -0.1
+0.5
177 -0.1
1
A: G 1 /4 threading
Model
Code
RT50200
RT50300
RT50400
RT50500
RT50600
RT50750
RT50900
RT51000
RT51500
RT51800
RT52000
RT52500
Depth
[mm]
177
177
177
177
177
177
177
177
177
177
177
177
Section
length
[mm]
45
45
45
45
45
45
45
45
45
45
45
45
Dimensional tolerances mm
mm
mm
mm
Rated thermal power (Qn)
TESI
Height
H
[mm]
200
302
402
502
602
752
902
1002
1502
1802
2002
2502
+0,5
+0,1
+2,0
+0,5
Conn. centres
H'
[mm]
133
235
335
435
535
685
835
935
1435
1735
1935
2435
-0,1
-0,5
-2,0
-0,5
Capacity Weight
[lt]
0,93
1,29
1,64
1,99
2,35
2,87
3,40
3,75
5,51
6,57
7,27
9,03
[Kg]
0,62
0,82
1,03
1,23
1,43
1,73
2,03
2,23
3,23
3,83
4,23
5,24
Qn at
EN442(t=50C)
[Watt]
31,7
51,4
66,5
81,3
95,9
117,4
138,5
152,4
220,9
261,3
288,0
354,5
Calculation Exponent
for t 50C
Q=Qn*(Dt/50)^n
1,35025
1,27553
1,29118
1,30683
1,32248
1,34596
1,36944
1,36397
1,33667
1,32733
1,32345
1,31376
Depth
Element length
Height
Connection centre
Calculated according to UNI EN442. Measurements carried out
on white epoxy powder painted models, at the Thermotechnical
Research and Measurement Laboratory of Milan Polytechnic.
Report ENE/MRT.ITPL.01005
Page 13
TESI
Sec Length
.
[mm] (*)
1
45
2
90
3
135
4
180
5
225
THERMAL HEAD
50
Standard models
Watt
Mod.
200
32
63
95
127
158
Mod.
300
51
103
154
206
257
Mod.
400
67
133
200
266
333
Mod.
500
81
163
244
325
407
Mod.
600
96
192
288
384
479
Mod.
750
117
235
352
469
587
Mod.
900
138
277
415
554
692
Mod.
1000
152
305
457
610
762
Mod.
1500
221
442
663
883
1104
Mod.
1800
261
523
784
1045
1306
Mod.
2000
288
576
864
1152
1440
Mod.
2500
354
709
1063
1418
1772
6
7
8
9
10
270
315
360
405
450
190
222
253
285
317
308
360
411
463
514
399
466
532
599
665
488
569
651
732
813
575
671
767
863
959
704
821
939
1056
1174
831
969
1108
1246
1385
914
1067
1219
1372
1524
1325
1546
1767
1988
2209
1568
1829
2090
2351
2613
1728
2016
2304
2592
2880
2127
2481
2836
3190
3545
11
12
13
14
15
495
540
585
630
675
348
380
412
444
475
565
617
668
720
771
732
798
865
932
998
895
976
1057
1139
1220
1055
1151
1247
1342
1438
1291
1408
1526
1643
1760
1523
1662
1800
1939
2077
1677
1829
1981
2134
2286
2429
2650
2871
3092
3313
2874
3135
3396
3658
3919
3168
3456
3744
4032
4320
3899
4254
4608
4963
5317
16
17
18
19
20
720
765
810
855
900
507
539
570
602
634
822
874
925
977
1028
1065
1131
1198
1264
1331
1301
1383
1464
1545
1627
1534
1630
1726
1822
1918
1878
1995
2112
2230
2347
2216
2354
2493
2631
2770
2439
2591
2743
2896
3048
3534
3754
3975
4196
4417
4180
4441
4703
4964
5225
4608
4896
5184
5472
5760
5672
6026
6381
6735
7090
21
22
23
24
25
945
990
1035
1080
1125
665
697
729
760
792
1079
1131
1182
1234
1285
1397
1464
1530
1597
1664
1708
1789
1871
1952
2034
2014
2110
2205
2301
2397
2464
2582
2699
2816
2934
2908
3047
3185
3324
3462
3201
3353
3505
3658
3810
4638
4859
5080
5300
5521
5486
5748
6009
6270
6531
6048
6336
6624
6912
7200
7444
7799
8153
8508
8862
26
27
28
29
30
1170
1215
1260
1305
1350
824
855
887
919
950
1336
1388
1439
1491
1542
1730
1797
1863
1930
1996
2115
2196
2278
2359
2440
2493
2589
2685
2781
2877
3051
3168
3286
3403
3521
3600
3739
3877
4016
4154
3963
4115
4267
4420
4572
5742
5963
6184
6405
6626
6793
7054
7315
7576
7838
7488
7776
8064
8352
8640
9216
9571
9925
10280
10634
31
32
33
34
35
1395
1440
1485
1530
1575
982
1014
1045
1077
1109
1593
1645
1696
1748
1799
2063
2129
2196
2262
2329
2522
2603
2684
2766
2847
2973
3068
3164
3260
3356
3638
3755
3873
3990
4107
4293
4431
4570
4708
4847
4725
4877
5030
5182
5334
6846
7067
7288
7509
7730
8099
8360
8621
8883
9144
8928
9216
9504
9792
10080
10989
11343
11698
12052
12407
36
37
38
39
40
1620
1665
1710
1755
1800
1140
1172
1204
1236
1267
1850
1902
1953
2005
2056
2395
2462
2529
2595
2662
2928
3010
3091
3172
3254
3452
3548
3644
3740
3836
4225
4342
4459
4577
4694
4985
5124
5262
5401
5539
5487
5639
5792
5944
6096
7951
8171
8392
8613
8834
9405
9666
9928
10189
10450
10368
10656
10944
11232
11520
12761
13116
13470
13825
14179
(*)
TESI
Add 24 mm overall clearance to the total length of the battery for the 1 /4" manifold plug.
To express the thermal output in Kcal/h multiply the value by 0,860 (1 Watt = 0,860 Kcal/h)
Page 14
H` 0.5
H2
R 25 0.2
33.5 0.5
TESI
Standard models
A
+0.5
45 -0.1
+0.5
215 -0.1
A: G 1 /4 threading
Model
Code
RT60200
RT60300
RT60400
RT60500
RT60600
RT60750
RT60900
RT61000
RT61500
RT61800
RT62000
RT62500
Depth
[mm]
215
215
215
215
215
215
215
215
215
215
215
215
Section
length
[mm]
45
45
45
45
45
45
45
45
45
45
45
45
Dimensional tolerances mm
mm
mm
mm
Rated thermal power (Qn)
TESI
Height
H
[mm]
200
302
402
502
602
752
902
1002
1502
1802
2002
2502
+0,5
+0,1
+2,0
+0,5
Conn. centres
H'
[mm]
133
235
335
435
535
685
835
935
1435
1735
1935
2435
-0,1
-0,5
-2,0
-0,5
Weight Capacity
[Kg]
1,09
1,52
1,94
2,37
2,79
3,42
4,06
4,48
6,59
7,86
8,70
10,81
[lt]
0,81
1,06
1,30
1,54
1,78
2,14
2,50
2,74
3,94
4,67
5,15
6,35
Qn at
Calculation Exponent
EN442(t=50C)
for t 50C
[Watt]
Q=Qn*(Dt/50)^n
37,4
1,37407
60,7
1,29293
78,5
1,31013
95,8
1,32732
112,8
1,34452
137,9
1,37032
162,6
1,39611
178,9
1,38772
259,1
1,34579
306,5
1,33389
337,9
1,33037
416,2
1,32159
Depth
Element length
Height
Connection centre
Calculated according to UNI EN442. Measurements carried out
on white epoxy powder painted models, at the Thermotechnical
Research and Measurement Laboratory of Milan Polytechnic.
Report ENE/MRT.RES.01003_C
Page 15
TESI
Sec Length
.
[mm] (*)
1
45
2
90
3
135
4
180
5
225
THERMAL HEAD
Standard models
50
Watt
Mod.
200
37
75
112
149
187
Mod.
300
61
121
182
243
304
Mod.
400
78
157
235
314
392
Mod.
500
96
192
287
383
479
Mod.
600
113
226
338
451
564
Mod.
750
138
276
414
552
690
Mod.
900
163
325
488
650
813
Mod.
1000
179
358
537
716
895
Mod.
1500
259
518
777
1036
1295
Mod.
1800
306
613
919
1226
1532
Mod.
2000
338
676
1014
1352
1690
Mod.
2500
416
832
1249
1665
2081
6
7
8
9
10
270
315
360
405
450
224
262
299
336
374
364
425
486
546
607
471
549
628
706
785
575
671
766
862
958
677
790
902
1015
1128
827
965
1103
1241
1379
976
1138
1301
1464
1626
1074
1252
1431
1610
1789
1554
1813
2073
2332
2591
1839
2145
2452
2758
3065
2027
2365
2703
3041
3379
2497
2913
3330
3746
4162
11
12
13
14
15
495
540
585
630
675
411
448
486
523
561
668
729
789
850
911
863
942
1020
1098
1177
1054
1149
1245
1341
1437
1241
1354
1467
1579
1692
1517
1655
1793
1931
2069
1789
1951
2114
2277
2439
1968
2147
2326
2505
2684
2850
3109
3368
3627
3886
3371
3678
3984
4291
4597
3717
4055
4393
4731
5069
4578
4994
5411
5827
6243
16
17
18
19
20
720
765
810
855
900
598
635
673
710
747
971
1032
1093
1153
1214
1255
1334
1412
1491
1569
1533
1628
1724
1820
1916
1805
1918
2031
2143
2256
2207
2344
2482
2620
2758
2602
2765
2927
3090
3252
2863
3042
3221
3399
3578
4145
4404
4663
4922
5181
4904
5210
5516
5823
6129
5407
5744
6082
6420
6758
6659
7075
7492
7908
8324
21
22
23
24
25
945
990
1035
1080
1125
785
822
860
897
934
1275
1336
1396
1457
1518
1648
1726
1805
1883
1962
2012
2107
2203
2299
2395
2369
2482
2595
2707
2820
2896
3034
3172
3310
3448
3415
3578
3740
3903
4066
3757
3936
4115
4294
4473
5440
5700
5959
6218
6477
6436
6742
7049
7355
7662
7096
7434
7772
8110
8448
8740
9156
9573
9989
10405
26
27
28
29
30
1170
1215
1260
1305
1350
972
1009
1046
1084
1121
1578
1639
1700
1761
1821
2040
2118
2197
2275
2354
2491
2586
2682
2778
2874
2933
3046
3159
3271
3384
3586
3724
3861
3999
4137
4228
4391
4553
4716
4879
4652
4831
5010
5189
5368
6736
6995
7254
7513
7772
7968
8275
8581
8888
9194
8786
9124
9461
9799
10137
10821
11237
11654
12070
12486
31
32
33
34
35
1395
1440
1485
1530
1575
1158
1196
1233
1271
1308
1882
1943
2003
2064
2125
2432
2511
2589
2668
2746
2969
3065
3161
3257
3353
3497
3610
3723
3836
3948
4275
4413
4551
4689
4827
5041
5204
5366
5529
5692
5547
5725
5904
6083
6262
8031
8290
8549
8808
9067
9501
9807
10114
10420
10726
10475
10813
11151
11489
11827
12902
13318
13735
14151
14567
36
37
38
39
40
1620
1665
1710
1755
1800
1345
1383
1420
1457
1495
2186
2246
2307
2368
2428
2825
2903
2981
3060
3138
3448
3544
3640
3736
3832
4061
4174
4287
4400
4512
4965
5103
5241
5378
5516
5854
6017
6180
6342
6505
6441
6620
6799
6978
7157
9327
9586
9845
10104
10363
11033
11339
11646
11952
12259
12165
12503
12841
13178
13516
14983
15399
15816
16232
16648
(*)
TESI
Add 24 mm overall clearance to the total length of the battery for the 1 /4" manifold plug.
To express the thermal output in Kcal/h multiply the value by 0,860 (1 Watt = 0,860 Kcal/h)
Page 16
SPECIAL OPTIONS
Curved batteries
Curved batteries are available with an inside radius of curvature not less than 1.0 m for TESI 2 and TESI
3 and not less than 1.3 m for TESI 4, TESI 5 and TESI 6.
The length of the battery must not exceed the semicircumference. The curvature is carried out according
to the customers specifications. Curved batteries are supplied with a primer coat only.
a
R
R me int
d
R ext
pxn
c = 2 x R med x sen ( 2 x R med )
R med =
R ext + R int
2
p = section pitch
n = number of elements
a = angle of curvature of the battery (max. 180)
c = distance between connections
d = distance of the battery from the wall
TESI
Page 17
Corner radiators
1
90 corner radiators are available on request with one or two corners and 1 /4 connections.
Corner radiators are supplied with a primer coat only.
TESI
Dimensions in mm
n x 45
13
65
40
40
18.5
40
n
40
(n - 1) x 45
TESI
Page 18
TESI
imensions in mm
(n x 45) - 5
101
40
40
40
n
40
(n - 1) x 45
TESI
Page 19
TESI
Dimensions in mm
n x 45
36,5
139
40
40
41,5
40
n
40
(n -1) x 45
TESI
Page 20
TESI
Dimensions in mm
17,5
n x 45
177
40
40
22,5
40
n
40
(n - 1) x 45
TESI
Page 21
TESI
Dimensions in mm
215
( n x 45 ) - 1.5
40
40
1.5
3.5
40
n
40
( n - 1) x 45
TESI
Page 22
H +- 0.5
TESI 2
TESI 3
TESI 4
TESI 5
TESI 6
4 +- 0.5
H +- 2
( n -1 ) x 45
TESI
Page 23
50 +- 1
The connections centres at 50 mm fixed for all models of radiators, allows to put the pipes for water input and
output independently by dimensions of the radiator.
It is possible to substitute the radiator with another one, different for height of for sections number, without
necessity to change the position of inlet and outlet pipes.
The flow diverter must be inserted between first and second sections, to close the direct way input-output for the
water flow.
TESI
Page 24
NIPPLING
All batteries of the same height can be nippled together.
The self-centering ring nuts make the task easier by absorbing the height tolerances.
Even though the special white silicone seal ring cannot be seen from the exterior, it guarantees a
perfect seal.
Painted batteries can be nippled together on the building site without having to remove the external
packaging.
Model code
TESI 2
RT2
TESI 3
RT3
TESI 4
RT4
TESI 5
RT5
TESI 6
RT6
XXX0200
XXX0300
XXX0400
XXX0500
XXX0565
XXX0600
XXX0665
XXX0685
XXX0750
XXX0765
XXX0865
XXX0885
XXX0900
XXX1000
XXX1500
XXX1800
XXX2000
XXX2500
40
40
40
40
40
40
40
40
26
22
22
18
40
40
40
40
40
40
40
40
40
40
40
40
40
40
22
20
20
15
40
40
40
40
40
40
40
40
35
35
30
30
30
30
18
15
15
12
40
40
40
40
40
30
30
30
15
15
15
12
40
40
40
40
35
25
25
25
15
15
15
12
TESI
Page 25
Side connection
Opposite connection
Top connection.
Welded diverter.
TESI
Page 26
Side connection.
Long battery.
Side connection
with external probe
TESI
Bottom connection
with welded bush.
Page 27
WALL INSTALLATION
brackets
(Pat. Int)
CHELA brackets consist in a clamp made of die-cast aluminium which clasps the tubes of TESI
radiators.
The minimum number of recommended CHELA brackets for walls in a good state of repair are:
TESI 2
h up to
1000 mm
h more than 1000 mm
TOP
1+ 1 every 10 sections
1+ 1 every 8 sections
BOTTOM
2
2
TESI 3
h up to
1000 mm
h more than 1000 mm
1+ 1 every 8 sections
1+ 1 every 6 sections
2
2
It is possible to use CHELA brackets with TESI 4, TESI 5 and TESI 6 if the weight of the radiator is
supported by at least two floor standing brackets for each battery.
TESI
Page 28
1
3
Wall spacers
30 cm wall version;
version with screw anchor
L : mm 97,5- 117,5 137,5
TESI
15.5 0.1
L1
Page 29
Wall brackets
We recommend IRSAP brackets during installation which can all either be fixed with screw anchors (1)
or walled (2).
L1
Load capacity of TESI brackets (with 3 mm deflection):
1
Model
kg
TESI 2
75
TESI 3
52
TESI 4
160
TESI 5
100
TESI 6
64
L2
L3
TESI
TESI
TESI
TESI
TESI
2
3
4
5
6
Total
length L1
[mm]
Depth
in wall L2
[mm]
Axis-wall
distance L3
[mm]
Screw anchor
diameter
[mm]
Screw anchor
length
[mm]
173
192
211
230
249
70
70
90
90
90
66
85
84
103
122
12
12
16
16
16
78
78
95
95
95
Maximum number of sections per battery that can be supported by two brackets
(Values refer to a brick wall in a good state of repair).
TESI
Model code
TESI 2
RT2
TESI 3
RT3
TESI 4
RT4
TESI 5
RT5
TESI 6
RT6
XXX0200
XXX0300
XXX0400
XXX0500
XXX0565
XXX0600
XXX0665
XXX0685
XXX0750
XXX0765
XXX0865
XXX0885
XXX0900
XXX1000
XXX1500
XXX1800
XXX2000
XXX2500
30
35
40
50
50
50
50
50
43
36
32
26
30
35
40
50
49
46
42
41
38
37
33
33
32
29
20
17
15
12
25
30
40
50
50
50
50
50
50
50
50
50
50
50
46
38
35
28
20
20
30
40
50
43
37
33
23
19
17
14
20
20
30
30
28
23
20
18
12
10
9
7
Page 30
ACCESSORIES
TESI radiators have a vast accessory range.
Nipples
Nipples with white silicone seal rings for joining two or more batteries.
Diaphragm
IRSAP supplies a diaphragm, or mobile flow diverter to optimise radiator
performance. During installation it can be inserted into the first delivery
section of radiators with bottom connections, especially if the radiator is
more than 1000 mm high or only has a few sections.
Fittings
TESI
Page 31
Spanner
Purpose-made tool recommended for tightening painted or chromium
plated plugs or bushes.
Made of plastic non-scratch material, the IRSAP spanner will not
damage the factory finish of the fittings.
TESI
Page 32
Brackets
Designed especially for TESI radiators and painted with epoxy
powder in WHITE STANDARD RAL 9010 or the Serie COLOR, the
brackets can be all either be fixed with a screw anchor or walled.
(Pat.Int.)
CHELA wall brackets have been specially designed for IRSAP
radiators and are protected by international patents. They are easy
and quick to install. Thanks to their functional and elegant design,
CHELA blend harmoniously with the radiators and guarantee a
perfect, strong grip. The amount of available variations permits total
reversibility in wall and side installations. All CHELA brackets are
available in standard WHITE RAL 9010 and the Serie COLOR.
TESI
Page 33
Towel rail
The unique design of this towel rail blends harmoniously with
radiator.
Thanks to the special brackets (Int. Pat.) it can be assembled on
TESI multiple column radiators and SINTESI single column radiators
without using a screwdriver or other tools.
The TESI TOWEL RAIL comes in the following sizes:
220 mm for radiators with 6 or more sections
310 mm for radiators with 7 or more sections
400 mm for radiators with 9 or more sections
580 mm for radiators with 13 or more sections
The TOWEL RAIL is available in standard WHITE RAL 9010 and the
Serie COLOR.
Hooks
From the Les Appliques series, these single and triple hooks made of
die-cast aluminium are useful bathrobe hangers. Thanks to the special
brackets for vertical tubes (Int. Pat.) the hooks can easily assembled on
TESI, SINTESI and SINTESI SPECCHIO without having to use a
screwdriver or other tools.
Available in STANDARD WHITE RAL 9010 and the Serie COLOR
Humidifier (Pat.Pend.)
An innovative water container made of plastic. Specially styled to
blend with the design of TESI and SINTESI. Thanks to the aluminium
hook (Int. Pat.) it can easily be positioned on the radiator at the desired
height.
Size: 95x245x60 mm.
Available in the standard WHITE RAL 9010 and in the Serie COLOR.
Touch-up paint
TESI
Page 34
TESI
Page 35