DEAD LEGS BIOCIDE TREATMENT

Equipment/PID Location Line number


valve
TAG
Remarks Done Yes/no
LV3002 by pass 6"PW400028 1 No
FE3000 by pass 8"GH300018 2 No
Drain header to closed drain 4"DF350001 3 No
Oil outlet to closed drain 1"DF350288 4 No
water outlet to 8'' oily water header 6'' PW400028 require flexible No
LDG 3000 No
LDT 3001 No
LDT 3002 No
LG 3003 No
LT 3004 No
LT 3005 No
Link water/oil outlet 6"GH300038 5 Yes
Sampling oil outlet 18"GH300040 6 Yes
Drain header to closed drain 4"DF350002 7 Yes
water outlet to 8'' oily water header 6'' PW400001 require flexible No
LDG 3010 Yes
LDT 3011 Yes
LDT 3012 Yes
LG1 3013 Yes
LG2 3013 Yes
LDT 3014 Yes
LDT 3015 Yes
10'' GH300127 No
10'' GH300128 No
12'' GH300129 No
12'' GH300130 No
DS301 outlet to closed drain C523A-P 8 Yes
Outlet EC313A to closed drain 2"DF350211 9 No
1" EC313A body drain cold side 1" 10 No
Outlet EC313B to closed drain 2"DF350213 11 Yes
1" EC313B body drain cold side 1" 12 Yes
Outlet EC313C to closed drain 2"DF350215 13 Yes
1" EC313C body drain cold side 1" 14 Yes
Outlet EC313D to closed drain 2"DF350217 15 Yes
1" EC313D body drain cold side 1" 16 Yes
EC313 A/B/C/D by bass cold side 16"GH300096 17 Yes
Link water/oil outlet 3"GH300071 18 Yes
Drain header to closed drain 4"GH300075 19 Pressure balanced by LG drain Yes
water sampling connection 4 ''PW 300073 Yes
LDG2 3020 Yes
LDT 3021 Yes
LDT 3022 Yes
LG1 3023 Yes
LG2 3023 Yes
LG3 3023 Yes
LT 3024 No flushing line No
LT 3025 No flushing line No
GX310A suction strainer drain 2"DF350080 20 to be done even if pump not running Yes
GX310A discharge drain 2"DF350077 21 to be done even if pump not running Yes
GX310A suction vent 1"GH310074 22 to be done even if pump not running Yes
GX310B suction strainer drain 2"DF350080 23 to be done even if pump not running No
GX310B discharge drain 2" 24 to be done even if pump not running No
GX310B suction vent 1"GH310075 25 to be done even if pump not running No
PDV3201A by pass 2" by pass 26 Yes
1"Drain of DS320A inlet 1"DF350292 27 Yes
3" drain of outlet water 4"PW320028 28 Yes
GX320 discharge to oily water package 4"PW400006 29 Yes
try-cock Yes
LDG3204A Yes
LDT3202A Yes
LDT 3201A Yes
PDV3201B by pass 2" by pass 30 Yes
3" drain of outlet water 4"PW320016 31 Yes
EC321 by pass 4"PW320028 32 Yes
Oily water U/S EC321 to open Drain 2"DO360079 33 Yes
Oily water to sand jet DS400 3"PW400058 34 Yes
Oily water to sample box 2"PW400042 35 Yes
1"Drain of DS320B inlet 3/4" 36 Yes
try-cock Yes
LDG3204B Yes
LDT3202B Yes
LDT 3201B Yes
DS401( Vendor PID) Drain D/S LV4007 3/4" 37 Yes
GX400A discharge drain to closed drain 1"DF350244 38 Yes
GX400B discharge drain to closed drain 1"DF350245 39 Yes
GX400B PSV 4012B 1 1/2'' PW400054 Yes
GX400A PSV 4012A 2 1/2'' PW400056 Yes
CA310 water condensate pot 2'' PW400004 require flexible Impossible
GX350A recirculation line 2"DF350222 40 Yes
GX350B recirculation line 2"DF350223 41 Yes
DEAD LEG WHILE DS 320B BY PASS
GX320: pump stopped
DS320B/1955(02) Mini flow GX320 2"PW320025 In Service
GX320 unavailable for long time
GX320A suction line 6"PW320016 Drain by 3/4"drain valve
GX320A discharge line 4"PW320018 Drain by 3/4"drain valve
GX320B suction line 6"PW320017 Drain by 3/4"drain valve
GX320B discharge line 4"PW320019 Drain by 3/4"drain valve
Instruction: Flush 2 hours after the beginning of biocide treatment
Location Pump Yes / No
DS300 GX822B No
DS301 GX822B Yes
DS302 GX822B No
PSV3130A (or B) CANCELLED No
DA350 GX822B Yes
Suction
GX722/721A/B GX822B Yes
\\vboxsrv\conversion_tmp\scratch_5\[246836791.xls.ms_office.xls]Dead legs
Injection point of Biocide Treatment
PSV3130: no more biocide required due to bonnet destruction of PSV.
Not in Service
PSV3130A/B
DS300/ 1950
DS301/1951
EC313/1953 (01/02)
Skimmed oil pipe
DA350/1866
DS320A/1955(02)
DS302/1953 (02/02)
GX310/1954
DS320A/1955(01/02)
DS320B/1955(02/02)