Вы находитесь на странице: 1из 14

4 Day Training Program

On
Fire Fighting, Plumbing Design
(Codes: NBC, NFPA, IPC, ASPE etc..)
15
th
Feb To 18
th
Feb 2014
AT VITS HOTEL, Andheri -Kurla Road
Andheri(E)
About the Workshop:
This 4 days training program has been designed to cover
the following topics:
Fire-Fighting Design (Day 1 and 2)
Plumbing Design (Day 3 and 4)
There would be an interactive question-answer round for
the benefit of the participants at the end of each day.
Who should attend:
Consulting Engineers / Project Managers / Project Engineers
Facility Managers / Engineers & End Users
Contract Managers and installers / Commissioning Engineers
Fire-Fighting Engineers and Technicians
HVAC Designers, Consultants and Engineers
Plumbing Engineers and Professionals in the Industry
Requisites for the Workshop:
The above course includes the Training Material.
Candidates should bring the issued course material, scientific calculator and
laptop (optional) regularly to the class, as the training will include extensive
calculations and candidates will be required to participate actively during the
training sessions.
Syllabus
Fire-Fighting Design:
Introduction, Classification of Fire
Manual hand held Fire Cylinders Types, Using Procedure & General
Maintenance Instructions.(NFPA-10)
Active and Passive Fire Protection Systems, Refuge Area.
Stairwell Pressurization System
Fire Water Sump Sizing, Overhead Tank Sizing,
Sprinklers Types, Selection, Designing, Pipe sizing (NFPA-13)
Wet Pipe System, Dry Pipe System, Pre-action System, Deluge System,
Combined Dry Pipe & Pre-action System, Antifreeze System
Fire Hose System (NFPA-14)
Fire Hydrant & underground Piping System(NFPA-24).
FM200 System Designing [Waterless Fire Protection system]:
Capacity, Pipe Sizing, Nozzle Selection (NFPA 2001)
NFPA (National Fire Protection Association) & NBC (National
Building code of India) for Fire Fighting System Designing
Fire-Fighting Design (contd.):
Fire Fighting Hydraulic Calculations, Head Loss.
Pump Head Calculations for High Rise Buildings
Fire Water Pump [Main Pump, Jockey Pump and Diesel Pump]
Classification Types and Selection (NFPA-10)
Diesel Fuel Storage Tank capacity calculation for the Diesel pump.
Foam System (NFPA-11&16)
Fire Alarm System Designing, Smoke Detector (Ionization Type, Optical)
Heat Detector, Linear Heat Detection Cable, Flame Detector
VESDA - Aspirating System
ELITE - Fire Hydraulic Calculation Software.
Syllabus
Plumbing Design:
Common Sanitary Fixtures Details: Standard trap pipe
and discharge pipe sizes, standard slopes for the discharge pipes:
(a) wash basin, (b) water closet (c) showers (d) sinks (e) bath tubs
(f) bidets (g) urinals (h) floor drains (floor gullies)
Layout of Sanitary Fixtures in Toilets.
Formula for flow through pipes :
(a) Darcy formula (b) Chezys formula (c) Manning formula (d) Hazen formula
(e) Reynolds Number (Laminar/ Turbulent Flow)
Piping Material, Types of Valves, NPSH calculations, Pump laws.
Water supply in buildings: (a) Direct system (b) Pumped system
Ground level (or) underground reservoir sizing
Elevated roof tank (storage cistern) sizing
Pump selection (HP, watts).
Water pipe sizing in buildings
Minimum number of smaller diameter water pipes that can be connected to
bigger diameter pipes. Plumbers chart for pipe sizing, Box formula
Plumbing Design (contd.):
Foul water drain in building stack, Branch drain/discharge pipe horizontal
drain. Fixture unit rating, Maximum number of discharge units allowed in
stack, Single stack system, Design of horizontal drains by discharge units
method
Septic tank, Soak away pits, Dispersion trenches designing
Designing of Storm Water Drainage in buildings
Auto pneumatic system, Pressure Tank Sizing
External water supply for building. Garden water supply & fountain water
pipe sizing, Calculation of storage tank, Garden water fountain designing,
Fountain pump selection.
Estimating Hot Water Demand, Heater Capacity selection.
Flush Water & Potable Water Loop sizing - (Software)
Designing of common appurtenances, Inspection chambers and Junction
manholes.
Water Balancing Calculations Green Buildings
NBC, IPC, ASPE Standards
Software: TECs Plumbing System Designing Templates.
Contact:
ISHRAE MUMBAI CHAPTER
Program Coordinator: Ms. Reema Varadkar
Phone: +91 22 2493 3701, 2493 2611
Mobile: 09860184542
Email: mumbai.programs@gmail.com
reema.ishrae@gmail.com
About the Faculty:
Syed Moazzam Ali is M.Tech., IGBC-AP has 15+ years of (Gulf & Indian) MEP
Designing experience, formerly worked as a faculty in Engineering College,
Holds Life Membership of FSAI & ISHRAE and trained many Professionals.
Conducted Trainings for ISHRAE, IEF, Bangalore university & FSAI.
He is expert in the MEP field and is the Technical Director of Taiba
Engineering Consultants[TEC-MEP Institute].
Syed Moazzam Ali
(PhD),M.Tech,
Life Member FSAI, ISHRAE
Technical Director
TEC-MEP Institute
Taiba Engineering Consultants
Website: www.TaibaMEP.com
Phone: +91 40 646 04442
Mobile: +91 9963 759411, +91 9848 461870
About ISHRAE:
The Indian Society of Heating, Refrigerating and Air Conditioning
Engineers was founded in 1981 at New Delhi by a group of eminent
HVAC&R professionals. ISHRAE has more than 12,000 HVAC&R
professionals and 5,000+ students as members with over 39
chapters and sub-chapters in India and abroad. It conducts
International and National Expositions, Seminars and Workshops
to achieve its primary objective of furthering the Arts and Sciences
of Heating, Refrigerating and Air Conditioning.
ISHRAE has published several Technical Guides and
Handbooks on subjects related to Air Conditioning,
Refrigeration and Ventilation, and worked on developing
Indian Weather Data files (WEDCO) project. ISHRAE is an
associate of ASHRAE.
Venue:
VITS Hotel, Anderi-Kurla Road
Andheri (E)
Important Dates:
Dates of Workshop 15
th
February, 2014 (Sat) to 18
th
February, 2014 (Tue)
Reporting Time 09:00 hrs. to 09:30 hrs. on 15
th
Feb, 2014
Program Timings 09:30 hrs. to 18:00 hrs.
Registrations close on 10
th
Feb, 2014
Spot registration at venue subject to availability
Fees:
15,000 /- per Individual. (This includes course material and lunch.)
12,000/- ISHRAE and ASHRAE members
Companies/ organizations sending 5 or more delegates get a
discount of 10%.
Discounts cannot be combined.
Payments options:
Pre-registration
Demand Draft/ Pay Order
Cheque (outstation cheques to include clearing charges @ 50 per cheque)
To be drawn on ISHRAE Mumbai Chapter
Spot Registration (subject to availability)
Credit Cards (VISA/ MasterCard)
Debit Cards
Cash
Schedule Highlights:
09:00 to 09:30 Registration and Networking (first day only)
09:30 to 13:00 Sessions 1 & 2 (with a tea break in between)
13:00 to 13:40 Lunch
13:40 to 16:30 Sessions 3 & 4 (with a tea break in between)
16:30to 17:00 Question /Answer session
ISHRAE Mumbai
Training Program
conducted by
Taiba Engineering
Consultants
Glimpse from the previous successful workshop
Looking forward to your
presence at the workshop
Thank you

Вам также может понравиться