Вы находитесь на странице: 1из 96

Balluff has

the right
transducer
for any
application!
Rod styles
Profile styles
Tubular styles
Embeddable style
Explosion-proof style

Rod Style

Explosion-proof
Rod Style

Rugged,
Compact
Rod Style

3/4x16-UNF threads
Pressure-rated to 8700 PSI

W K

Rugged, all-stainless steel

for use in hydraulic cylinders


Replaceable electronics head
Analog signal adjustable in field

housing
Designed for demanding
applications
Eliminates the need for
protective covers
3/4-16-UNF threads
Pressure-rated to 8700 PSI

Compact,
bolt-in
Rod Style

Rugged, all-stainless steel


housing
Bolt-in design
Pressure-rated to 8700 PSI
Eliminates the need for
protective cover

Embeddable
Rod Style

EX E
Factory Mutual & CENELEC

Designed for use in hydraulic

approved
Class I, Div 1, Groups A,B,C,D;
Class II/III, Div 1, Groups E,F,G
II G EEx d IIC T6 IP68
Extremely rugged, bolt-in
stainless steel housing

cylinders
Space-saving embeddable
design
Field-replaceable electronics
module

Profile
Housing

Designed for external mounting


Rugged aluminum extruded

LowProfile
Housing

Lowest-profile for space

Advanced
Tube Profile
Housing

AT

Magnetostrictive technology

critical applications
Compatible with rod-in-cylinder
housing available with freefloating magnet or captive-sliding
type linear potentiometers
magnet
Unique design eliminates bearing
Same form factor as many linear
wear problems associated with
potentiometers and other lowerrod-in-cylinder designs
grade magnetostrictive sensors

at a potentiometer price
0 - 10 V analog &
start/stop interface
IP 67

Sensor Output Options

Analog
0...10 V and 10...0 V
-5...+5V and +5...-5 V
-10...+10 V and +10...-10 V
4...20 mA or 20...4 mA
0...20 mA or 20...0 mA
Digital
Start/Stop, RS422
Pulse-Width Modulated, RS422
PWM (w/recirculations),RS422
Specialized
Synchronous Serial Interface*
CANopen
Profibus DP
Quadrature

Resolution

0.1 mV (analog)
0.2 mA (analog)
16 bit (analog)
Controller-dependent (Start/Stop & PWM)
1,2,3,5,10 mm selectable (Quadrature output)
1,5,10, 20,40 mm selectable (SSI output)
5 mm increments selectable (CANopen & Profibus)
10 mm

Stroke Length

2 - 156

2 - 156

2 - 156

2 - 140

2 - 156

2 - 156

2 - 156

2 - 60

Quick disconnect
Cable-out

24 V DC (20%)
15 V DC (2%)
* (24 or 25 bit binary or gray code)

Active measurement area: 2 to 156


(Consult factory for longer lengths)

Wiring Options

Operating Voltage

Pages 9-20

Pages 21-30

Pages 31-40

Pages 49-54

Pages 41-48

Pages 55-66

Pages 67-78

Pages 79-84

Designed TOUGH for real-world applications

The rugged choice for extreme conditions.

The waveguide consists of a special


nickel-iron alloy with 0.7 mm O.D.
and 0.5 mm I.D.
A copper conductor is introduced
through the length of this tube. The
start of measurement is initiated by a
short current pulse. This current
generates a circular magnetic field
which rotates around the waveguide.
A permanent magnet at the point of
measurement is used as the marker
element, whose lines of field run at
right angles to the electromagnetic
field.

strictive effect causes an elastic


deformation of the waveguide, which
propagates along the waveguide in
both directions in the form of a
mechanical wave.
The mechanical wave is converted
to an electrical signal by the signal
converter. The propagation time of
the mechanical wave is determined
by the position of the permanent
magnet and can be determined to
resolutions down to 1 mm.

In the area on the waveguide where


the two fields intersect, a magneto-

Accessories

Setup is a snap with


Balluff accessories!
Magnets

Floats

Non-contact floats
with integrated
permanent
magnet measure
liquid level

Non-contact!
BTM Module
Provides up to 4 channels of
analog position and/or velocity
feedback!

Connectors
Connect with Balluff and
decrease your setup and
down time!

Micropulse
Linear Position
Transducers
With more than 80 years
of experience in the field
of sensor technology,
Balluff is now one of the
most capable
manufacturers
of electronic and
electromechanical
sensors, linear
transducers, and
identification systems.
Located just south of
Cincinnati, Ohio in
Florence, Kentucky,
Balluffs North American
headquarters serves
markets in the United
States, Canada and
Mexico. The wooded
setting surrounding the
two-story, 58,000 square
foot facility belies its high
tech mission and
phenomenal growth. Two
major building expansions
since 1986 have been
fueled by a yearly sales
growth of twenty-five
percent.

Company Overview
& History

The most recent expansion


has increased manufacturing
and product design
capabilities, as well as added
a world-class training center.
These developments support
Balluffs continued growth in
application-specific,
technology-driven customer
solutions. From simple part
presence detection to tough
positioning and sensing
applications, Balluff is
positioned as the partner of
choice for North American
sensing solutions.

Producing leading-edge sensor


products requires exceptional
accuracy and reliability. Testing
and calibration take place
throughout the manufacturing
process to insure top
performance.

State-of-the-art shipping
operations allow same day
shipping, expedited delivery
on in-stock items and
24-hour on-call service!

Balluff Inc. is the North


American headquarters of
Neuhausen, Germany-based
Balluff GmbH, a worldwide
maker of sensors,
transducers, ID systems and
industrial automation
components. The company
employs over 100 at the
Florence location, and more
than 1000 worldwide.

Balluffs high level of


employee satisfaction
and low turnover are the
backbone of efficient
manufacturing and
assembly processes.
Great people = great
products!

The Balluff advantage


80 years of..
Innovative
technology
State-of-the-art
electronics
Application-specific
customer solutions

Gebhard Balluff founds a


mechanical repair shop in
Neuhausen for bicycles,
motorcycles and sewing
machines.

1921

II

Development of patented
electromechanical limit switches.
Balluff becomes an automotive
and machine tool industry
partner.

Company expansion in
Production of inductive
Neuhausen with addition of
proximity switches begins. a new plant.

1956

1968

1976

1-800-543-8390 www.balluff.com

Micropulse
Linear Position
Transducers

North American
Locations

INTRO

Balluff Canada, Inc.


Mississauga, Ontario
CANADA

The North American Network


Balluff home offices in North America
service a qualified sales and distribution
network spanning the continent from
top to bottom. Our North American
operations support customers in
industries ranging from machine tool to
robotics, injection molding, packaging,
material handling and more.

Florence, Kentucky USA


Our Florence, Kentucky location is
conveniently located within the
Cincinnati Tri-state area, and is just
minutes from the Greater Cincinnati
Northern Kentucky International Airport.
Home of Balluffs North American
operations, the Florence plant has
recently expanded to a 2-story 58,000
square foot facility with more than 100
employees.

Balluff Inc.
Florence, Kentucky
USA

Balluff de Mexico
Queretaro, Mexico

Mississauga, Ontario CANADA


Balluff Canada serves the Canadian
marketplace with a network of experienced distributors across all provinces
and territories.
Balluff USA

Queretaro, MEXICO
Located in the thriving town of
Queretaro, our new and expanding
sales center is within range of some
of the largest industrial operations
in Mexico.

Balluff Canada

To locate your local


Balluff distributor, visit
http://www.balluff.com/distributors/
or call 1-800-543-8390

Production of optoelectronic
switches begins.

Production of microprocessorcontrolled limit switches used


with angle encoders begins
Production of rotary encoders
begins.

Founding of Balluff Inc. in


New Jersey, USA by John
Goyer, President and CEO.

Addition of a second
plant in Neuhausen.
Production of identification
systems begins.

1978

1979-1980

1981

1984

www.balluff.com 1-800-543-8390

III

Micropulse
Linear Position
Transducers

Product Range
& Customers

Our Products
Our product range is
engineered for tough
positioning and part
sensing applications in a
variety of automated
machinery environments. Our history
designing and producing rugged limit
switches for the
automotive industry
provides the basis for
our continued research
and development of
tough, cutting-edge
sensing technologies.

Sensors

Magnetic Field Sensors

Tubular Inductives

Block-style Inductives

Capacitives

Optoelectronics

Electromechanicals

MicropulseTM Transducers Transducer Accessories

Sensor Systems

Identification Systems

AS-Interface Systems

Remote Systems

Connectors/Accessories

Innovative
solutions for a
wide range of
industries and
automation
processes!

TM

Industries &
Applications
Our primary customer
base in the metalworking,
automotive and plastics
industries has provided a
stable base from which our
technological innovation has
branched into a broad array
of applications.

The rugged choice for extreme conditions.


Assembly automation
Automotive: body and assembly
Bottling
Ceramics and glass
Hydraulics & pneumatics

Balluff, Inc. relocates


to Florence, KY.

Production of
linear transducers begins.

1986

1987

IV

Injection molding
Material handling
Metal cutting
Metal forming
Packaging

Paper and textiles


Plastics
Plastics and rubber
Robotics
Welding

Main manufacturing
plant opens in
Vesprem, Hungary.

Expansion of Florence, KY
plant to 40,000 sq. feet.

1989

1994

1-800-543-8390 www.balluff.com

Micropulse
Linear Position
Transducers

Technical &
Customer Service

INTRO

Customer Service
One Call Does It All. Easy. Fast. Personal.
Were dedicated to your
success.
Quick service, exceptional
products and experienced
employees are yours when
you call Balluff. We are a
world leader in sensor
technology with a team of
the best people in the
industry ready to solve your
automation challenges. We'll
make your search for the
right sensor easier, faster,
and less stressful.

Well get to know you.


Our service is based on
geography, so you'll speak
with the same people every
time you call. We'll get to
know your order history and
delivery preferences so you
don't have to waste time
repeating the same requests
over and over!

Let our
experienced
professionals
help you choose
the right sensor!

Give us a call.
You will be instantly connected with experienced
customer service, technical
support and application
engineers who know the
industry - your industry. We
know how to make your
work easier, and will go out
of our way to make sure
you are satisfied with our
products and services. WE
are what separates us from
the competition!

Technical Service/Application Engineering


Finding the best sensor
means first selecting the
correct sensing technology.
Our customer service
representatives work handin-hand with the best
application engineers and
technicians in the industry.
Our experienced application
engineering group will help
you choose the best sensor
for your application regardless of the technology used.
If an optical sensor is better
than an inductive sensor,
well know. We manufacture
all major types of sensing
technologies and understand better than anyone
where to apply a particular
technology.

Over time, Balluff has


developed a reputation in
the industry for solving the
difficult applications. We live
up to this reputation
everyday. How do we do it?

Founding of
Balluff Canada.

1998

1999

www.balluff.com 1-800-543-8390

Products and
people.
No other sensor company
has our broad range of
products or the customer
and technical experience to
support it. Go ahead, give
us a test. We love a
challenge!

New logistics and production


center opens in Neuhausen,
Germany

New North American


President,
CEO Kent Howard.

24 Hour on-call service


Same-day shipping: In
by 2 p.m., out same day!
Adequate service or
parts shipped free!
Expedited delivery on
in-stock items
Fast, friendly service
guaranteed
Direct stop technical
support
Product selection &
application assistance
Direct tech support
Cross references
Competitive pricing
Customized solutions
just ask!
Experienced service and
technical support

We find the
best sensor for
your application
and apply it
correctly.

Founding of Balluff Mexico

18,000 square foot expansion of USA


facility to enhance manufacturing and
testing of inductive proximity sensors and
Micropulse magnetostrictive linear
position sensors.

2000

2001

2002

Micropulse
Linear Position
Transducers

Germany
World Headquarters
Gebhard Balluff GmbH & Co.
Gartenstrasse 21-25
D-73765 Neuhausen/Filder
Tel.: (++49 71 58) 1 73-0
Fax: (++49 71 58) 50 10
E-mail: balluff@balluff.de
Web: www.balluff.de

Argentina
Nortcnica S.R.L.
103 Heredia 638
1672-Villa Lynch-San Martin
Pcia. De Buenos Aires
Argentina
Tel.: (++54 11) 7 57 31 29
Fax: (++54 11) 7 57 10 88
E-mail:
nortecnica@synectis.com.ar
Australia
Balluff-Leuze Pty. Ltd.
2 Rocco Drive
Scoresby, VIC 3179
(Melbourne) Australia
Tel.: (++61 3) 97 64 23 66
Fax: (++61 3) 97 53 32 62
E-mail:
balluff_leuze@matcol.com.au
Austria
Gebhard Balluff Vertriebs
Ges.m.b.H
Industriestr. B 16
2345 Brunn am Gebirge
Tel.: (++43 22 36) 3 25 21-0
Fax: (++43 22 36) 3 25 21-46
E-mail: sensor@balluff.de
Belgium/Luxembourg
Geveke Industrial Belgium
Multitechnic nv
Leuvensesteenweg 250 A
1800 Vilvoorde
Tel.: (++32 2) 257 02 40
Fax: (++32 2) 257 02 49
E-mail: info@geveke.be
Brazil
Balluff Controles Eltricos Ltda.
Rua Francisco Foga, 25
Distrito Industrial - Vinhedo
CEP 13280.000
Sao Paulo
Tel.: (++55 19) 38 76 56 11
Fax: (++55 19) 38 76 27 63
E-mail: balluff@balluff.com.br

Canada
Balluff Canada, Inc.
2840 Argentia Road, Unit #2
Mississauga, Ontario L5N 8G4
Canada
Toll-free:1-800-927-9654
Tel.: (905) 816-1494
Fax: (905) 816-1411
E-mail: balluff.canada@balluff.ca
Web: www.balluff.ca

VI

Global
Locations

China
Shanghai De-Tong Co., Ltd.
Balluff South China
Service Center
Dept of Applied Physics
Shanghai Jiao Tong University
Hua Shan Road 1954
Shanghai 200030 PRC China
Tel.: (++86 21) 62 83 31 75
Fax: (++86 21) 62 81 29 18
E-mail: detong@online.sh.cn
Croatia
SAS Hstec d.d.
Jadranska Cesta B B
2300 Zadar
Tel: (++385 23) 23 31 52 79
Fax: (++385 23) 23 31 57 93
E-mail: sas-hstec@zd.tel.hr
Czech Republic
Balluff CZ s.r.o.
Peluskova 1400
CZ-198 00 Praha 9 - Kyie
Tel: (++42 02) 81 94 01 25
Fax: (++42 02) 81 94 01 02
E-mail: cz@balluff.de
Web: www.balluff.de/cz
Denmark
Desim Elektronik ApS
Tsingevej
9500 Hobro, Jylland
Denmark
Tel.: (++45) 70 22 00 66
Fax: (++45) 70 22 22 20
E-mail: desim@desim.dk
Finland
Murrelektronik
Koukkukatu 1
15700 Lahti
Finland
Tel.: (++358 3) 8 82 40 00
Fax: (++358 3) 8 82 40 40
E-mail: murrelektronik.oy@sci.fi
France
Balluff S.A.S.
ZI Nord De Torcy - Bat 3
Rue Des Tanneurs - BP 48
77201 Marne La Valle Cedex 1
Tel: (++ 33 1) 64 11 19 90
Fax: (++33 1) 64 11 19 91
E-Mail: info@balluff.fr

Great Britain
Balluff UK MultiSwitch
The Old Mill
Finney Lane
Cheadle, Cheshire SK8 3DF
Tel: (++44 161) 4 37 12 34/5/6
Fax: (++44 161) 4 36 14 35
E-mail: sales@balluff.co.uk

Greece
S. Nazos A.E.
Vertrieb/Service fr Balluff
73 Verias
GR-57008 Thessaloniki
Tel.: (++30 31) 78 02 27
Fax: (++30 31) 78 41 44
E-Mail: nazos.s.a.@netfiles.gr
Hong Kong
NO. 42, 18th St.
Hong Lok Yuen
Tai Po, NT, Hong Kong
Tel.: (++852) 26 51 01 86
Fax: (++852) 26 51 03 88
Web: www.balluff.com.hk
E-mail: sensortech@attglobal.net
Hungary
Balluff Elektronika KFT
Marketingiroda
Vihar u. 22/4
1221 Budapest
Tel: (++36 1) 2 29 20 95
Fax: (++36 1) 2 29 20 95
Web: www.balluff.hu
E-mail: sales@balluff.hu

India
B.I. Enterprise
B-210, Arjun Centre,
Govandi Station Road,
Govandi, Mumbai 400 088
Tel.: (++91 22) 5 56 80 97,
5 56 59 66
Fax: (++91 22) 5 56 08 71
E-mail: balluff@bom5.vsnl.net.in

Iran
ITS Iran Technical Supply Co.
3rd Floor, No. 141
Sohrevardi
Shomali Ave.
Teheran, Iran
Tel.: (++98 21) 8 76 37 31
Fax: (++98 21) 8 76 95 36
E-mail: its@irost.com

Israel
Ancitech LTD.
21, Haorgim St. 21b
Industrial Zone Holon 58857
Tel.: (++972 3) 5 56 83 51
Fax: (++972 3) 5 56 92 78
E-mail: ancitech@netvision.net.il

Italy
Balluff Automation S.R.L.
Corso Gambione 63
10134 Torino
Tel.: (++39 011) 3 17 04 44
Fax: (++39 011) 3 17 01 40
E-mail: balluff02@interbusiness.it
Japan
Nihon Balluff Co. Ltd.
274 Gomyo Tamagawa-mura
Hiki-gun
Saitama, 355-0343
Tel.: (++81 493) 65 57 71
Fax: (++81 493) 65 31 71
E-mail: balluff@balluff.co.jp
Korea
KOBALT Co. Ltd.
U-Chong Bldg., Room 613
196, Anyang 7 Dong, Manan-KU
Anyang City, Kyungki-Do 430-017
Tel: (++82 343) 4 67 25 39
Fax: (++82 343) 4 67 28 60
E-mail: hspark@hanmec.co.kr

1-800-543-8390 www.balluff.com

Micropulse
Linear Position
Transducers

Global
Locations

INTRO

Mexico
Balluff de Mexico
Ave. Meson del Prado #292
Fracc. Juriquilla
Queretaro, QRO 76230
Tel.: (++52 442) 234-1587
Fax: (++52 442) 234-1586
E-mail: balluff.mexico@balluff.com
Netherlands
Vierpool b.v.
Industrieweg 2
NL-3606 AS Maarssen
Tel.: (++31 346) 59 45 11
Fax: (++31 346) 57 40 55
Norway
Primatec as
Lillesandsvn. 44
NL-4890 Grimstad
Tel.: (++47) 37 25 87 00
Fax: (++47) 37 25 87 10
E-mail: primatec@online.no
Poland
Balluff Sp. z o.o.
ul. Powsinska 106
PL-02-903 Warszawa
Tel./Fax: (++48 22) 6 51 96 79
Tel./Fax: (++ 48 71) 8 42 97 28
E-mail: balluff@balluff.pl

Portugal
LA2P, LDA.
Rua Almirante Sousa Dias
Loja D - Nova Oeiras
P-2780 Oeiras
Tel.: (++351 21) 4 42 26 58
Fax: (++351 21) 4 42 28 08
E-mail: la2p@ip.pt

South Africa
Retron
P.O. Box 39448
Bramlay, 2018 (Johannesburg)
Tel.: (0027 11) 7 86 05 53
Fax: (0027 11) 4 40 82 75
E-mail: info@retron.co.za

Singapore
Balluff Asia Pte. Ltd.
BLK 1004 Toa Payoh Ind. Park
Lorong 8, #03-1489
Singapore 1231
Tel.: (++65) 2 52 43 84
Fax: (++65) 2 52 90 60
E-mail: balluff@balluff.com.sg

Spain
Elion S.A.
Farell 5
E-08014 Barcelona
Tel.: (0034 93) 2 98 20 20
Fax: (0034 93) 2 98 20 48
E-mail: automatismos@elion.es
Web: http://www.elion.es

Slovakia
S & A, Ltd.
Celno 567/62
976 98 Podbrezov - Lopej
Tel.: (++421) 8 67-61 72-903,904
Fax: (++421) 8 67-61 72-250
E-mail: saa@nextra.sk

Sweden
Balluff Svenska Elektronik AB
Vikhemsvgen 9
S-241 38 Eslv
Tel.: (0046 413) 6 92 20
Fax: (0046 413) 6 92 21

Slovenia
Senzorji SB
prozvodnja,
trgovina in stroitve d.o.o.
Ul. Pohorskega bataljona 14
2000 Maribor
Tel./Fax: (++386 62) 4 29 63 70
Tel./Fax: (++386 62) 4 29 63 71
E-mail: sb.elektronika@siol.net

Switzerland
Balluff Sensortechnik AG
Riedstr. 6
8953 Dietikon
Tel.: (0041 1) 7 40 87 20
Fax: (0041 1) 7 40 87 05
E-mail: sglaser@balluff.de

Taiwan
Canaan Electric Corp.
6F-5, No. 63 Sec. 2
Chang-An East Road
RC-Taipei
Tel.: (00886 22) 5 08 23 31
Fax: (00886 22) 5 08 47 44
E-mail:
canaan1@ms15.hinet.net

Turkey
Mega-Teknik
Perpa Tic.Is.Mrk. A. Blok
Kat:2, No:9/0026
80270 Okmeydani Istanbul
Tel.: (++90 212) 3 20 04 11
Fax: (++90 212) 3 20 04 16
E-mail: mega@netone.com.tr
USA
North American
Headquarters
Balluff, Inc.
8125 Holton Drive
Florence, KY 41042
Tel.: 1-800-543-8390
Fax: (859) 727-4823
Web: www.balluff.com
E-mail: balluff@balluff.com

BALLUFF Your partner around the world.


www.balluff.com 1-800-543-8390

VII

Contents

non-contact

Micropulse
Linear Position
Transducers

1-800-543-8390 www.balluff.com

Micropulse
Linear Position
Transducers

Contents
Product Introduction
& Applications

INTRO

Pages 4-8
Standard Rod Style

BTL

Pages 9-20
Compact, Rugged
Rod Style
Thread-in

BTL

Pages 21-30
Compact, Rugged
Rod Style
Bolt-in

BTL

Pages 31-40
Explosion Proof
Rod Style Series

Ex

BTL

Pages 41-46
Embeddable Rod Style
Series

BTL

Pages 47-54
Profile Series

BTL

Pages 55-66
Low Profile Series

BTL

Pages 67-78
Advanced Tube Profile
Series

AT

BTL

STANDARD WARRANTY
BALLUFF Inc. products are guaranteed to be free from defects in material and
workmanship as follows:
Standard 2-year warranty from
the date of shipment for
photoelectric and flow sensors,
capacitive sensors, read-write ID
systems, magnetostrictive
transducers (MicropulseTM AT)*,
connectors and cables,
electromechanical limit and rotary
switches, and all products with
electromechanical relays sold to the
original user.
Standard lifetime warranty for
inductive sensors and magnetically
operated sensors sold to the
original user.
* MicropulseTM AT:
1-year warranty from
date of shipment

part, installation, labor or


Balluff Inc. will repair or replace
consequential damages of any kind.
at our discretion, without charge,
BALLUFF Inc. assumes no
any unit, which fails because of
defective workmanship or material, responsibility for selection and
installation of its products. The
during this guarantee period and
which is returned to BALLUFF Inc. foregoing is in lieu of all other
guarantees expressed, implied or
transportation prepaid. The
statutory and BALLUFF Inc. neither
guarantee will not apply if, in the
assumes nor authorizes any person
judgement of BALLUFF Inc.,
damage or failure has resulted from to assume for it any other
accident, alteration, misuse, abuse, obligation or liability in connection
or operation on an incorrect power with said products.
supply. The
guarantee
expressly
These sensors are NOT approved for use in personnel safety applications.
does not
A sensor failure or malfunction can result in either an energized or
include any
de-energized output state. Never use these sensors for personal
safety. Doing so may result in serious bodily injury or death.
other costs
Only products specifically designated as safety products are designed to
such as the
meet OSHA and ANSI standards for point-of-operation devices.
cost of
For safety grounding issues please refer to the technical section in the
removal of
end of this catalog.
the defective

www.balluff.com 1-800-543-8390

WARNING

Pages 79-84
Connectors &
Accessories

BKS

Pages 85-92
Processors, Positioning
module, Digital displays,
BTA module

BTA

Pages 93-100
Terms

T
Pages 101-104

Micropulse
Linear Position
Transducers
Balluff transducers are the
rugged choice for use
under extreme ambient
conditions and over
measuring distances
between 50mm (2") and
4000mm (156").
Various output signal
formats are available for
integration into your
specific control system.

Obtaining accurate position


feedback is a critical part of
many automation
processes. Without
accurate, reliable
measurement feedback,
quality and production
suffer. The Micropulse
line of linear transducers
has been providing a high
level of linear measurement
for years.

In addition, we offer
processor cards with a
variety of programming
functions, for generating
digital or analog data for
processing in your control.

Micropulse transducers
incorporate some of the
most advanced features
found in any
magnetostrictive linear
transducer.

Features:
Auto Tuning
Non-contact
Wear free
Replaceable electronic
modules (REMs)
IP 67 & IP 68
Analog, Digital, SSI,
Pulse, CANopen,
Profibus and
Quadrature

Product
Introduction
Advantages:
Compared with traditional
position feedback systems,
Balluff transducers offer the
following advantages:

Insensitive to shock,
vibration, temperature,
contamination, moisture
and electrical noise
Wear and maintenance
free, thanks to noncontact principle of
operation
Absolute output signal,
even after voltage
interruption, no
re-homing of the
machine necessary
High resolution,
repeatability and linearity
Simple installation,
marker element (magnet)
needs no power
IP 67 per DIN 40 050
Pressure-rated to 8700
PSI, for internal hydraulic
cylinder installation

The CE-Marking confirms


that our products meet the
requirements of the EC
Directive 89/336/EWG
(EMC Directive) and the
EMC Law. Testing done in
our EMC Laboratory, which
is accredited by the DATech
for Electromagnetic
Compatibility Testing,
Balluff products have been
shown to meet the EMC
requirements of the Generic
Standard EN 50 081-2
(Emission) and EN 50 0822 (Noise Immunity). See the
corresponding user's
manual for detailed
information.

1-800-543-8390 www.balluff.com

Micropulse
Linear Position
Transducers

Applications

INTRO

Applications:
Balluff transducers offer
features which assure
reliable operation in many
areas of automation and
process technology under
extreme conditions:
Hydraulic cylinders
Tooling and tool handling
Presses
Casting and rolling mills
Foundries
Injection molding
Levelling machines
Transport systems
Lift controls
Level monitoring
Tunnel boring equipment
Die casting machinery
Portal robots
Woodworking machinery
Flight simulators
Cutting/slitting machinery
Conveying
Packaging machines
Wire and cable
Windmills
Elevators
Food processing
Forestry
Semiconductor
equipment

Film slitting machine

Hydraulic press

FM

Metal saw

Hydraulic press

Mechanical
eccentric press

www.balluff.com 1-800-543-8390

Steam valve positioning

Micropulse
Linear Position
Transducers

Applications

Continuous,
absolute
position
feedback

Sawmill machinery

Hydraulic cylinder
with transducer

Concrete construction machinery

Off-road equipment

Injection molding machine

Withstands the rigors


1-800-543-8390 www.balluff.com

Micropulse
Linear Position
Transducers

Applications

INTRO

Highly
accurate
Superreliable
Maintenancefree!

Micropulse Ex technology is designed


for use in the most hazardous locations

Wind power generator

Bottling machinery

Dosimetry
cylinder
Dosimetry and
mixing unit

Visit our solutions


center online:
www.balluff.com/micropulse

of harsh, real-world applications!


www.balluff.com 1-800-543-8390

Z Standard Rod Style


The Z style product line is
one of the most versatile
lines in the Micropulse
family. With all the
electrical options,
interfacing to your control
system will never be a
problem.
Built into the hydraulic
cylinder, or external, the
transducer provides
continuous, absolute
position feedback.
The Z housing offers a
variety of outputs,
replaceable electronics
and the ability to adjust
analog signal in the field.

Micropulse
Z Style

Introduction

Features:
Applications:
Balluff transducers offer
Absolute, non-contact
features, which assure
position feedback
General Specifications...pg. 10
reliable operation in many
Electrical Options...pgs. 11-13

Highly accurate, super


areas of automation and
Accessories...pgs. 14-15
reliable, maintenance-free
process technology, even
Installation Guidelines...pg. 16
Heavy duty stainless steel
under extreme ambient
Wiring Diagrams...pg. 17
pressure tube
conditions:
How to order...pg. 18
Rated to 8700 psi
Hydraulic cylinders
Replaceable Electronics
Tooling and tool
Module
handling
-Plug and play field repair,
Presses
fluid circuit remains in- tact
Casting and rolling mills
Reduced downtime
Foundries
One moduleany
Injection molding
stroke length
Leveling machines
Wide variety of
Transport systems
available outputs
Lift controls
-Analog voltage or
Level monitoring
current
Digital
START/STOP
Tunnel boring
equipment
-Digital Pulse-WidthModulated (PWM)
Die casting machinery
Synchronous
Serial
Portal robots
Replaceable electronics module (REM)
Interface
(SSI)
Woodworking
-CANopen
machinery

Flight simulators
Cutting/slitting
machinery
Conveying
Packaging machines

-Profibus-DP
-Quadrature

Windmills
Elevators

www.balluff.com 1-800-543-8390

BTL

100 % scalable output


signal (analog versions)
User-scalable using
supplied programming
tool
Programming tool is
removable to guard
against tampering
Three programming
modes to suit any
application requirement
Teach-In Used to set
the zero and end
values anywhere within
the nominal factory
stroke range
Adjust Used to perform
manual adjustment of
output signal values
Online Adjust Used to
perform real-time
adjustment of output
signal without disrupting
the control-loop

Micropulse
Z Style

Dimensions
General Specifications

Z Standard Rod Style

Series
Available lengths
Output signals

Z Style
51mm (2 in) to 3962mm (156 in)
Analog, Digital Pulse, SSI, CANopen, Profibus, Quadrature
D = 50.8 for standard versions (Z Style)
D = 30 for metric version (B Style)
A

0.5/O25
B

Nominal stroke = measuring area

25

29

Mounting Surface

Measurement type
Measurement range
Shock rating
Vibration rating
Environmental protection
Housing material
Pressure rating (rod)
Operating temperature
Storage temperature
Humidity
Connection type
Noise immunity
Approvals
Accessories:
Magnets are on page 14
Float magnets are on page 14
Connectors are on page 15
(Additional connectors start
on page 85)
Jam nuts are on page 15

A (mm)

B (mm)

C (mm)

Digital

57

69

48

Analog, SSI,
Quadrature

74

69

48

82.5

69 3

102.5

71 3

CANopen

Profibus

0117A001

Ordering Code

Rod End
threaded M4x6 hole

Thread 3/4-16 UNF for Z Style (jam nut not included)


Thread M18x1.5 for B Style (jam nut included)

Interface
C

60

O10.2

46

BTL-5-__-M___-Z-____(see ordering code on page 18)


Linear displacement
51mm (2 in) to 3962mm (156 in)
100g for 6ms (100g for 2ms continuous) per IEC 68 2-27
12g, 10 to 2000 Hz per IEC 68-2-6
IP 67- with connector attached
anodized aluminum body, stainless investment cast flange
(DIN 1.3952), 316 stainless steel tube
600 bar (8700 PSI) max
-40 to + 1850 F
-40 to + 2120 F
<90% non-condensing
connector or integral cable
ESD, RFI and BURST per IEC 1000-4-2/3/4/6, severity level 3
CE
Warning:
These products are not rated for safety applications.

Calibration device BTL-5-Programming tool

Supplied with analog versions

10

1-800-543-8390 www.balluff.com

Micropulse
Z Style

Analog
Voltage
A, B, G

Analog
Current
E,C

Digital
Start/Stop & PWM
P, M, I, L, K

Output

0...+10V,-5...+5V,-10...+10V

0...20 mA, 4...20 mA

Output load
Resolution
Non-linearity

>2KW (5 mA max)
0.33 mV
+
100mm to 500mm stroke,
+0.02 % over 500mm stroke
Resolution/ min 2m
5m
2KHz

500W
0.66 A
+
100mm to 500mm stroke,
+
0.02 % over 500mm stroke
Resolution/ min 2m
5m
2KHz

[150 V/ C +
(5ppm/C*P*V/NL)] * DT
24 Vdc +20% or
15 Vdc +2%
<150 mA
(at 1K Hz sampling rate)

[0.6 A/C +
(10 ppm/C*P*V/NL)] * DT
24 Vdc +20% or
15 Vdc +2%
<150 mA
(at 1K Hz sampling rate)

Start/Stop or Pulse-widthmodulated (RS422/RS485)


per spec
Controller dependent
+
100mm to 500mm stroke,
+
0.02 % over 500mm stroke
Resolution/ min 2m
5m
500 Hz stroke >2000mm
1KHz stroke <2000mm
[0.6 A/C +
(10 ppm/C*P*V/NL)] * DT
24 Vdc +20% or
15 Vdc +2%
<150 mA
(at 1K Hz sampling rate)

Temperature coefficient*
Operating voltage
Operating current

Notes:
Analog voltage output
versions incorporate both
rising and falling outputs.
Analog current version must
be ordered as rising or
falling ouputs.
*Temperature coefficient
variables:
V = output range in V
I = output range in [mA]
DT = temperature change
P = magnet position

Output Options

Ordering Code

0...10V

-5...+5V

-10...+10V

4...20mA

0...20mA

Start/Stop

Trailing-edge active

Start/Stop

Leading-edge active

Start/Stop
Trailing-edge, tri-state

High Z

Gate Pulse

L&R

PWM

Stop Pulse

Leading-edge active

0117A002

Digital Outputs

Repeatability
Hysteresis
Sampling rate

BTL

Analog Outputs

Electrical interface
Electrical type
Part No. Code

Electrical Options

Active Stroke

Analog and Digital Output Options for the Micropulse Z Style

RS-485 signal transmission with digital outputs

www.balluff.com 1-800-543-8390

11

Micropulse
Z Style

Ordering Code
Resolution
Non-linearity
Repeatablity (resolution +
hysteresis)
Hysteresis
Sampling rate
Temperature coefficient *
Operating voltage
Operating current
Network isolation
Network speed
Network compatibility
Address selection
Communication types
Configuration software
Number of magnets supported
Notes:
For more technical
information, see
pages 101-103

Network Options

Electrical Options
CANopen

Profibus

This interface provides an efficient


connection to machines using
CANopen. Features include:
- Process data objects
incorporating position, velocity
and set-point information
- Emergency object for set-points
- Service data objects for
configuring transducer modes
- Synchronization objects for
network wide activities

This interface provides an efficient connection


to machines using Profibus. Features of this
interface include:
- Single telegram message for fast updates
even with 4 magnets
- Operates at 12 Mbps
- GSD file provided to configure telegram
message
- Sync and Freeze functions available for
coordination between other devices

Position 5m, Velocity 0.1mm/s


increments(selectable)
30m at 5m resolution
1 digit

Position 5m (configurable)
Velocity 0.1mm/s increments (configurable)
30m at 5m resolution
1 digit

1 digit
1kHz
(6m + 5ppm x L)/C
24 Vdc 20%
100 mA
yes
10, 20, 50, 100, 125, 250,
500, 800, 1000 kBaud
CiA Standard DS301
Rev. 3.0 (Encoder Profile)
Software
Producer/consumer
none required
1,2 or 4

1 digit
1kHz
(6m + 5ppm x L)/C
24 Vdc 20%
120 mA
yes
9.6, 19.2, 93.7, 187.5,
900, 1500, 1200 kBaud
EN 50170
(Encoder Profile)
DIP switch
Master/Slave
GSD file
1,2 or 4

Data Format

Data Format

Position

Position (1 per magnet)


32-bit integer

32-bit integer

Velocity

Velocity (1 per magnet)

16-bit integer

32-bit integer

Set
points
8-bit integer

BTL5-H1_ _-Mxxxx-Z-S92

BTL5-T1_ 0 -Mxxxx-Z-____

Baud Rate
0 = 1MBaud
1 = 800 kBaud
2 = 500 kBaud
3 = 250 kBaud
4 = 125 kBaud
5 = 100 kBaud
6 = 50 kBaud
7 = 20 kBaud
8 = 10 kBaud
Process Data
1 = 1 x position & 1 x velocity
2 = 2 x position & 2 x velocity
3 = 4 x position
Stroke Length
xxxx = length in mm (see chart on page 18)

12

Connection Type
S 103 = 3 connectors:
Power: 3-pin male, M8
Bus in: 5-pin male, M12
Bus out: 5-pin female, M12
S 86 = 12-pin female
No. of Magnets
1 = 1 magnet
2 = 2 magnets
3 = 4 magnets
Stroke Length
xxxx = length in mm
(see chart on page 18)

1-800-543-8390 www.balluff.com

Micropulse
Z Style

Specialized Interfaces
SSI

Quadrature

The SSI (synchronous serial interface)


output interfaces with popular control
systems from manufacturers such as
Allen-Bradley, Delta Computer,
Siemens, Parker and many others.
Cable spans can be up to 400m with
noise-free operation. The internal
linearization of this interface makes it
ideal for applications requiring the
best accuracy available.

The quadrature output interfaces


directly to standard encoder inputs
(90 out of phase, A & B). This
configuration gives you more
interface options for connecting to
motion based systems. Operating
modes can be either free-running or
synchronous (switch selectable)
depending on the control system's
requirements.

Ordering Code
Resolution
Non-linearity

1, 5, 10, 20 or 40m
(see ordering code below)
30m or 2LSBs, whichever is greater

1, 2, 5 10m, 0.001 or 0.0001


(switch selectable)
100mm to 500mm stroke, 0.02% over
500 mm stroke
resolution +
(2 x resolution or 5m, whichever is greater)
2 x resolution or 5m, whichever is greater
Free-running: 1ms, 2ms, 4ms
Synchronous: 500S to 10ms
(6m + 5ppm xL)/C
10, 200, 400, 800 kHz
Free-running or Synchronous
(switch selectable)
24 Vdc 20% or 15 Vdc 2%
80mA
Standard A & B (RS-422 level)

Repeatablity (resolution +
hysteresis)
Hysteresis
Sampling rate
Temperature coefficient *
Communication speeds
Output modes
Operating voltage
Operating current
Output

Electrical Options

1 digit
1 digit
2KHz
(6m + 5ppm xL)/C
100, 200, 400, 500, 1000 kHz
24 or 25 bits
(binary or gray code)
24 Vdc 20%
80mA
Standard RS-485/422 levels

Direction

Notes:
SSI Maximum cable lengths
Cable length
Clock Freq.
<25 m
<1000 kHz
<50 m
<500 kHz
<100 m
<400 kHz
<200 m
<200 kHz
<400 m
<100 kHz

BTL

Direction

Pulse sequence
1

2
t

23

24

tv
out of
range

tm
MSB

LSB

BTL5-S1_ _-Mxxxx-Z-____
Connection Type
S 32 = Connector
KA02 = 2m PUR cable
KA05 = 5m PUR cable
KA10 = 10m PUR cable
KA15 = 15m PUR cable
System Resolution
1 = 1m
2 = 5m
3 = 10m
4 = 20m
5 = 40m
Coding
0 = Binary code, rising (24 bits)
1 = Gray code, rising (24 bits)
6 = Binary code, rising (25 bits)
7 = Gray code, rising (25 bits)
Stroke Length
xxxx = length in mm
(see chart on page 18)

www.balluff.com 1-800-543-8390

BTL5-Q_ _ _ _-Mxxxx-Z-S140

Mode/Update Rate
0 = Synchronous
1 = free-running, 1ms update
2 = free-running, 2ms update
4 = free-running, 4ms update
System Resolution
0 = 1m
1 = 2m
2 = 5m
3 = 10m
6 = 0.0001"
7 = 0.001"
Quadrature Frequency
0 = 800 kHz
1 = 400 kHz
2 = 200 kHz
6 = 10 kHz
Supply Voltage
1 = +24 V
2 = 15 V
xxxx = length in mm
(see chart on page 18)

13

Micropulse
Z Style
Product
Type

Ordering Code
Material
Weight
Magnet speed
Operating/storage
temperature

Product
Type

Ordering Code
Material
Weight
Operating/storage
temperature
Water displacement
Pressure (static)

14

Accessories
Magnets & Floats
Magnet
32 ring

Magnet
32 open ring

Magnet
25 ring

Magnet
22 ring

BTL-Z-P-1013-4R

BTL-Z-P-1013-4S

BTL-Z-P-1012-4R

BTL-Z-P-1014-2R

AL
12g
any
-40+100C

AL
12g
any
-40+100C

AL
12g
any
-40+100C

AL
10g
any
-40+100C

Magnet
Barrel float

Magnet
Barrel float

Magnet
Bullet float

Magnet
Sphere float

BTL2-S-3212-4Z

BTL2-S-4414-4Z

BTL2-S-6216-8P

BTL2-S-5113-4K

Stainless 316
20g
-40+120C

Stainless 316
35g
-40+120C

Stainless 316
66g
-40+120C

Stainless 316
34g
-40+120C

35mm
24 bar

30mm
20 bar

41mm
15 bar

26mm
40 bar

1-800-543-8390 www.balluff.com

Micropulse
Z Style
Product
Type

Straight Connector
8-pin female

Accessories
Connectors

Right-angle Connector
8-pin female

Jam nut
3/4-16 UNF
10.5

BTL

3/4-16UNF

.7

27

Ordering Code
Material
Contact surface
Solder connection
Cable
Cable diameter
Cable material
Environmental rating
For additional connectors,
see page 85

0117A012

BKS-S 32M-___

BKS-S 33M-____

BTL-5-JAM-NUT

CuZn, nickel plated


0.8m Au
7 x 0.25mm2/AWG 24
68mm
PVC (PUR optional)
IP67 (when installed)

CuZn, nickel plated


0.8m Au
7 x 0.25mm2/AWG 24
68mm
PVC (PUR optional)
IP67 (when installed)

Stainless steel

Indicate cable length in ordering code


(consult factory for longer lengths)
00 = connector only
02 = 2 meter cable
05 = 5 meter cable

Replaceable Electronics Module (REMs)


In many applications, avoiding equipment downtime is
paramount. With that in mind, Balluff designed the Micropulse
rod-style Z housing with a field replaceable electronics module.
This unique feature allows the entire electronics package to be
replaced in the field in a matter of minutes. The plug-and-play
benefits of Balluffs patented Auto-Tuning circuitry allow one
REM module to be used for any stroke length. Of particular
importance in hydraulic cylinder applications, the rod portion
of the transducer stays in place the fluid circuit remains intact.
Replacement Electronics modules are available for the following
output types:
Analog Voltage, Analog Current

Digital START/STOP
Digital PWM

BTL-5-A11-Mxxxx-REM-S32
Output Signal
(see ordering code on page 18)
Connection Type
S 32 = Connector version
KA05 = Cable out (specify length)

www.balluff.com 1-800-543-8390

15

Micropulse
Z Style

Installation
Guidelines

Installation
The BTL Micropulse
transducer is provided with a
x 16-UNF (optional M18
1.5) mounting thread. We
recommend mounting into
non-magnetizable materials.
If magnetizable materials are
used, the installation must be
carried out as shown in the
drawing below. Sealing is at
the flange mounting surface,
using the supplied O-ring.

B Style (M18x1.5)

Z Style (3/4x16-UNF)

16

1-800-543-8390 www.balluff.com

Micropulse
Z Style

Wiring Diagrams

Analog Wiring Diagrams

Analog Voltage
15 V (A, B, G)

Analog Voltage
24 V (A, B, G)

2
4

1
View of mating
connector, wiring side

Analog output, falling

PK

GN

GY

Analog output, rising


Analog common

GY

Analog output, rising


Analog common

BN

BN

BU

+15 V

BU

+24 V

6
8

WH

WH

PK

GN

GND
GND

BTL

GND
-15 V

0117a022

0117a021

Connector

Analog output, falling

Analog Current
15 V (E, C)

Analog Current
24 V (E, C)

Cable out

YE

GY

Analog output
Analog common

+24 V

BN

BU

+ 15 V

GND
GND

WH

YE

GY

Analog output
Analog common

BN

BU

WH

GND
-15 V

0117a024

0117a023

Digital Wiring Diagrams


Digital, RS485 differential
24 V (P, M, I, K, L, R)
3

4
1
View of mating
connector, wiring side
6

YE

PK

GY

GN

BN

BU

WH

Digital, Single-ended
24 V (N)

Interrogate + Input

YE

Interrogate + Input

GY

Pulse + Output

Pulse - Output

BN

BU

+24 V

+24 V

WH

Interrogate - Input
Pulse + Output

GND
GND

Digital, RS485 differential


15 V (P, M, I, K, L, R)
YE

PK

GY

GN

BN

BU

WH

GND

0117a026

0117a025

GND

Digital, Single-ended
15 V (N)

Interrogate + Input
Interrogate - Input
Pulse + Output
Pulse - Output
+15 V
GND

YE

GY

Pulse + Output

BN

BU

+15 V

WH

Interrogate + Input

GND
- 15 V

0117a028

-15 V

0117a027

SSI Wiring Diagram

CANopen Wiring Diagram


SSI (S)
3

4
1
View of mating
connector, wiring side
6

YE

PK

GY

GN

BN

BU

CANopen (H)
+Clk
-Clk

5
1

+24 V
GND

CAN_LOW

+Data
-Data

CAN_HIGH

CAN_GND

+24 V

View of mating
connector, wiring side

GND

0117a030

0117a029

* Pin-8 (WH) must remain unconnected

Profibus Wiring Diagram

Quadrature Wiring Diagram


Profibus (T)

5 2
4 3

2 5

3 4

Power

View of mating
connector, wiring side

Bus Out (female)

4
1 3

Bus In (male)

0117a034

4
3
1
5
2
4
3
1
5
1
3
4

Quadrature (Q)

+RxD/TxD-N (A)
+RxD/TxD-P (B)
Data GND
VP +5 V (output)
shield

C
B J D
A K E
H G F

+RxD/TxD-N (A)
+RxD/TxD-P (B)
Data GND

View of mating
connector, wiring side

VP +5 V (output)
shield
+ 24 V

GN

WH/GN

GY

WH/GY

OR

WH/OR

WH/BU

BN

BU

WH/BN

A+
AB+
BZ+
ZSTRB Input
+24 V (+15 V)
GND
Not used (-15 V)

0117a035

GND
shield

Note:

= twisted-pair

www.balluff.com 1-800-543-8390

17

Micropulse
Z Style

Ordering Code
1

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
-

Balluff - Linear Transducer


Generation 5
Output Type
A = 0 to 10Vdc
B = -5 to +5Vdc
C = 0 to 20 mA
E = 4 to 20 mA
G = -10 to +10 Vdc
S = SSI*
T = Profibus*
H = CANopen*
Q = Quadrature*

I = Differential start/stop with tri-state


K = Differential stop - leading edge active
L = Differential pulse-width modulated
M= Differential start/stop - leading edge active
N = Single ended start/stop - leading edge active
P = Differential start/stop - trailing edge active
R = Differential pulse-width - recirculated

Supply Voltage
1 = 24 Vdc 20%
2 = 15 Vdc 2% (Not available for S, T or H output types)
Analog Output Operation (blank for digital)
Voltage type (Output type A, B & G)
1 = User selectable rising or falling
Current type (Output type C & E)
0 = Minimum output at connector end (rising towards opposite end)
7 = Maximum output at connector end (falling towards opposite end)

Normal Stroke Length


0

5 = 305mm active stroke

Housing Type
Z = Standard Rod Style (3/4"x16-UNF mounting threads and 50.8mm null zone)
B = Metric Rod Style (M18x1.5 mounting threads and 30mm null zone)
Connection Type
S

K A

2 = 8-pin quick disconnect metal connector


0 5 = Cable out (5m standard; specify length in meters)

Interrogation (only valid if output type = R, otherwise leave blank


I = Internal interrogation, E = External interrogation
Recirculation (only valid if output type = R, otherwise leave blank)
1=1 circulation, 2 = 2 circulations, 4 = 4 circulations, 8 = 8 circulations, 16 = 16 circulations
Standard Stroke Lengths (consult factory for additional lengths)
inches
2
3
3.5
4
5
6
7
8
9

18

mm
0051
0077
0090
0102
0127
0152
0178
0203
0230

inches
10
11
12
13
15
16
18
20
22

mm
0254
0280
0305
0330
0381
0407
0457
0508
0560

inches
24
26
28
30
32
36
40
42
48

mm
0610
0661
0711
0762
0813
0914
1016
1067
1220

inches
50
54
60
66
69
72
78
84
89

mm
1270
1372
1524
1676
1753
1829
1981
2134
2261

*See additional ordering


information on
pages 12-13
inches
mm
98
2490
108
2743
118
2997
126
3200
140
3556
144
3658
148
3759
152
3860
156
3962

1-800-543-8390 www.balluff.com

Compact Rugged Rod Style Thread-In


Compact, rugged and built
to last, the all stainless steel
W housing can withstand
the rigors of harsh,
real-world applications.
With its compact size and
built like a tank
ruggedness, the W
housing is the logical choice
for demanding applications.

Applications:
Hydraulic Cylinder

Primary/Wood
Mobile
Mining
Valve Control
Food Processing
Off-shore
Waste water
Pulp and paper

Features:
Rugged all stainless
steel housing
Designed for demanding
applications
Eliminates need for
protective covers
Pressure rated 8700 psi
x16- UNF threads
Outputs
- Analog (voltage or current)
- Digital start/stop
- Pulse with Modulates (PWM)
- PWM with recirculations
- SSI
Length 2 to 156

Micropulse
W Style

Introduction

General Specifications...pg. 22
Electrical Options...pgs. 23-24
Accessories...pgs. 25-26
Installation Guidelines...pg. 26
Wiring Diagrams...pg. 27
How to order...pg. 28

BTL

Quick disconnect and


cable out

www.balluff.com 1-800-543-8390

21

Micropulse
W Style

Dimensions
General Specifications

W Compact, Threaded Rod Style

Series
Available lengths
Output signals

W Style
51mm (2 in) to 3962mm (156 in)
Analog, Digital Pulse, SSI
D = 50.8 for standard versions (W Style)
D = 40 for metric version (H Style)
O65

Nominal stroke = measuring area

60

M4x4/6 threaded
blind hole,
security disk
O 9 DIN 6799

O10.2

43

O5 (4 places)
for spanner wrench
(70ft/lbs max torque)

0.5

25

Thread 3/4-16 UNF for W Style (jam nut not included)


Thread M18x1.5 for H Style (jam nut included)

Mounting Surface
Axial Connector
(right angle)
48

43

Axial Connector
(straight)
69

Axial Cable out


41

43

Radial Cable out

43

35

41
0117A052

Ordering Code
Measurement type
Measurement range
Shock rating
Vibration rating
Environmental protection
Housing material
Rod & flange material
Pressure rating (rod)
Operating temperature
Storage temperature
Humidity
Connection type
Noise immunity
Approvals
Accessories:
Magnets are on page 25
Float magnets are on page 25
Connectors are on page 26
(Additional connectors
start on page 85)

22

BTL-5-__-M___-W-____(see ordering code on page 28)


Linear displacement
51mm (2 in) to 3962mm (156 in)
10 g for 6ms (100g for 2ms continuous) per IEC 68 2-27
12g, 10 to 2000 Hz per IEC 68-2-6
IP 67, IP 68 for cable out
316 stainless steel
Tube: 316T stainless, flange: 316L
600 bar (8700 PSI) max
-40 to + 1850 F
-40 to + 2120 F
<90% non-condensing
connector or integral cable
ESD, RFI and BURST per IEC 1000-4-2/3/4/6, severity level 3
CE
Warning:
These products are not rated for safety applications.

1-800-543-8390 www.balluff.com

Micropulse
W Style
Analog
Voltage
A, B, G

Analog
Current
E,C

Digital
Start/Stop & PWM
P, M, I, L, K

Output

0...+10V,-5...+5V,-10...+10V

0...20 mA, 4...20 mA

Output load
Resolution
Non-linearity

>2KW (5 mA max)
0.1mV
+
100mm to 500mm stroke,
+
0.02 % over 500mm stroke
Resolution/ min 2m
4m
500 Hz stroke >2000mm
1KHz stroke <2000mm
[150 V/ C +
(5ppm/C*P*V/NL)] * DT
24 Vdc +20% or
15 Vdc +2%
<150mA
(at 1K Hz sampling rate)

500W
0.2A
+100mm to 500mm stroke,
+0.02 % over 500mm stroke
Resolution/ min 2m
4m
500 Hz stroke >2000mm
1KHz stroke <2000mm
[0.6A/C +
(10 ppm/C*P*V/NL)] * DT
24 Vdc +20% or
15 Vdc +2%
<150mA
(at 1K Hz sampling rate)

Start/Stop or Pulse-widthmodulated (RS422/RS485)


per spec
Controller dependent
+100mm to 500mm stroke,
+
0.02 % over 500mm stroke
Resolution/ min 2m
4m
500 Hz stroke >2000mm
1KHz stroke <2000mm
[0.6A/C +
(10 ppm/C*P*V/NL)] * DT
24 Vdc +20% or
15 Vdc +2%
<150mA
(at 1K Hz sampling rate)

Temperature coefficient*
Operating voltage
Operating current

Notes:
Analog voltage output
versions incorporate both
rising and falling outputs.
Analog current version must
be ordered as rising or
falling ouputs.

Output Options

*Temperature coefficient
variables:
V = output range in V
I = output range in [mA]
DT = temperature change
P = magnet position

Ordering Code

0...10V

-5...+5V

-10...+10V

4...20mA

0...20mA

Start/Stop

Trailing-edge active

Start/Stop

Leading-edge active

Start/Stop
Trailing-edge, tri-state

BTL

High Z

Gate Pulse

I
L&R

PWM

Stop Pulse

Digital Outputs

Repeatability
Hysteresis
Sampling rate

Analog Outputs

Electrical interface
Electrical type
Part No. Code

Electrical Options

Leading-edge active

Active Stroke
0117A045

Analog and Digital Output Options for the Micropulse W Style

RS-485 signal transmission with digital outputs

www.balluff.com 1-800-543-8390

23

Micropulse
W Style

Specialized Interfaces

Electrical Options
SSI

The SSI (synchronous serial interface)


output interfaces with popular control
systems from manufacturers such as
Allen-Bradley, Siemens, Parker and
many others. Cable spans can be up
to 400m with noise free operation.
The internal linearization of this
interface make it ideal for applications
requiring the best accuracy available.
S

Ordering Code
Resolution
Non-linearity
Repeatablity (resolution +
hysteresis)
Hysteresis
Sampling rate
Temperature coefficient *
Communication speeds
Output modes
Operating voltage
Operating current
Output

Notes:
SSI Maximum cable lengths
Cable length
Clock Freq.
<25 m
<1000 kHz
<50 m
<500 kHz
<100 m
<400 kHz
<200 m
<200 kHz
<400 m
<100 kHz

1, 5, 10, 20 or 40m
30m or 2LSBs, whichever is greater
1 digit
1 digit
500S
(6m + 5ppm xL)/C
100, 200, 400, 500, 1000 kHz
24 or 25 bits, binary or gray code
24 Vdc 20%
80mA
Standard RS-485/422 levels

Pulse sequence
1

2
t

23

24

tv
out of
range

tm
MSB

LSB

BTL5-S1_ _-Mxxxx-W-____
Connection Type
S 32 = Connector
KA02 = 2m PUR cable
KA05 = 5m PUR cable
KA10 = 10m PUR cable
KA15 = 15m PUR cable
System Resolution
1 = 1m
2 = 5m
3 = 10m
4 = 20m
5 = 40m
Coding
0 = Binary code, rising (24 bits)
1 = Gray code, rising (24 bits)
6 = Binary code, rising (25 bits)
7 = Gray code, rising (25 bits)
Stroke Length
xxxx = length in mm
(see chart on page 28)

24

1-800-543-8390 www.balluff.com

Micropulse
W Style
Product
Type

Magnet
32 ring

Magnet
32 open ring

Magnet
25 ring

Accessories
Magnets & Floats
Magnet
22 ring

BTL

Ordering Code
Material
Weight
Magnet speed
Operating/storage
temperature

Product
Type

Ordering Code
Material
Weight
Operating/storage
temperature
Water displacement
Pressure (static)

BTL-Z-P-1013-4R

BTL-Z-P-1013-4S

BTL-Z-P-1012-4R

BTL-Z-P-1014-2R

AL
12g
any
-40+100C

AL
12g
any
-40+100C

AL
12g
any
-40+100C

AL
10g
any
-40+100C

Magnet
Barrel float

Magnet
Barrel float

Magnet
Bullet float

Magnet
Sphere float

BTL2-S-3212-4Z

BTL2-S-4414-4Z

BTL2-S-6216-8P

BTL2-S-5113-4K

Stainless 316
20g
-40+120C

Stainless 316
35g
-40+120C

Stainless 316
66g
-40+120C

Stainless 316
34g
-40+120C

35mm
24 bar

30mm
20 bar

41mm
15 bar

26mm
40 bar

www.balluff.com 1-800-543-8390

25

Micropulse
W Style
Product
Type

Ordering Code
Material
Contact surface
Solder connection
Cable
Cable diameter
Cable material
Environmental rating
For additional connectors,
see page 85

Accessories & Installation


Straight Connector
S32

Right-angle Connector
S32

BKS-S 32M-____

BKS-S 33M-____

CuZn, nickel plated


0.8m Au
7 x 0.25mm2/AWG 24
68mm
PVC (PUR optional)
IP67 (when installed)

CuZn, nickel plated


0.8m Au
7 x 0.25mm2/AWG 24
68mm
PVC (PUR optional)
IP67 (when installed)

Indicate cable length in ordering code


(consult factory for longer lengths)
00 = connector only
02 = 2 meter cable
05 = 5 meter cable

Installation
The BTL Micropulse
transducer is provided with
a x 16-UNF (optional
M18 1.5) mounting
thread. We recommend
mounting into nonmagnetizable materials. If
magnetizable materials are
used, the installation must
be carried out as shown in
the drawing below. Sealing
is at the flange mounting
surface, using the
supplied O-ring.
H Style Housing

26

3
4

for magnetizable material


for non-magnetizable
material
a Spacer made of
non-magnetizable material
b Magnet

W Style Housing

1-800-543-8390 www.balluff.com

Micropulse
W Style

Wiring Diagrams

Analog Wiring Diagrams

Connector

Analog Voltage
15 V (A, B, G)

Analog Voltage
24 V (A, B, G)
2

4
1
View of mating
connector, wiring side
6

PK

GN

GY

Analog output, rising


Analog common

BN

BU

+24 V

WH

Analog output, falling

GND
GND

PK

GN

GY

Analog output, rising


Analog common

BN

BU

+15 V

WH

Analog output, falling

GND
-15 V

0117a022

0117a021

Cable out

BTL

Analog Current
15 V (E, C)

Analog Current
24 V (E, C)
1

YE

GY

Analog output
Analog common

BN

BU

+24 V

WH

GND
GND

YE

GY

Analog output
Analog common

BN

BU

+ 15 V

WH

GND
-15 V

0117a024

0117a023

Digital Wiring Diagrams


Digital, RS485 differential
24 V (P, M, I, K, L, R)
7

Connector

2
4

1
View of mating
connector, wiring side

YE

PK

GY

GN

BN

BU

WH

Interrogate + Input

Digital, Single-ended
24 V (N)

Interrogate - Input

YE

Pulse + Output

Interrogate + Input

GY

Pulse + Output

BN

BU

+24 V

WH

Pulse - Output
+24 V
GND
GND

0117a025

GND
GND

0117a026

Cable out
Digital, RS485 differential
15 V (P, M, I, K, L, R)
1

YE

PK

GY

GN

BN

BU

WH

Digital, Single-ended
15 V (N)

Interrogate + Input
Interrogate - Input
Pulse + Output
Pulse - Output
+15 V
GND
-15 V

YE

GY

Pulse + Output

BN

BU

+15 V

WH

Interrogate + Input

GND
- 15 V

0117a028

0117a027

SSI Wiring Diagram


SSI (S)
Connector

2
6

Cable out

1
View of mating
connector, wiring side

YE

PK

GY

GN

BN

BU

+Clk
-Clk
+Data
-Data
+24 V
GND

0117a029

* Pin-8 (WH) must remain unconnected

Note:

= twisted-pair

www.balluff.com 1-800-543-8390

27

Micropulse
W Style

Ordering Code
1
B

2
T

10 11 12 13 14
-

15 16 17 18 19 20 21 22 23 24
5

Balluff - Linear Transducer


Generation 5
Output Type
A = 0 to 10Vdc
B = -5 to +5Vdc
C = 0 to 20 mA
E = 4 to 20 mA
G = -10 to +10 Vdc
S = SSI*

I = Differential start/stop with tri-state


K = Differential stop - leading edge active
L = Differential pulse-width modulated
M= Differential start/stop - leading edge active
N = Single ended start/stop - leading edge active
P = Differential start/stop - trailing edge active
R = Differential pulse-width - recirculated

Supply Voltage
1 = 24 Vdc 20%
2 = 15 Vdc 2% (Not available for S, T or H outputs)
Analog Output Operation
(Leave Blank for Digital Versions)
Voltage type (Output type A, B & G)
1 = User selectable rising or falling
Current type (Output type C & E)
0 = Minimum output at connector end (rising towards opposite end)
7 = Maximum output at connector end (falling towards opposite end)
Normal Stroke Length
0 3 0 5 = 305mm active stroke
Housing Type
W= Compact, threaded rod style, 3/4-16 UNF threads, 2 inch null point
H= Compact, threaded rod style, M18x1.5 threads, 30mm null point
Connection Type
S 3 2 = 8-pin quick disconnect metal connector
K

A 0

= Axial cable out (5m standard; specify length in meters)

5 = Radial cable out (5m standard; specify length in meters)

Interrogation (only valid if output type= R, otherwise leave blank


I = Internal interrogation, E = External interrogation
Recirculation (only valid if output type= R, otherwise leave blank)
1=1 circulation, 2 = 2 circulations, 4 = 4 circulations, 8 = 8 circulations, 16 = 16 circulations
Standard Stroke Lengths (consult factory for additional lengths)
inches
2
3
3.5
4
5
6
7
8
9

28

mm
0051
0077
0090
0102
0127
0152
0178
0203
0230

inches
10
11
12
13
15
16
18
20
22

mm
0254
0280
0305
0330
0381
0407
0457
0508
0560

inches
24
26
28
30
32
36
40
42
48

mm
0610
0661
0711
0762
0813
0914
1016
1067
1220

inches
50
54
60
66
69
72
78
84
89

mm
1270
1372
1524
1676
1753
1829
1981
2134
2261

*See additional ordering


information on page 24
inches
98
108
118
126
140
144
148
152
156

mm
2490
2743
2997
3200
3556
3658
3759
3860
3962

1-800-543-8390 www.balluff.com

Compact Rugged Rod Style Bolt-In

Micropulse
K Style

Introduction

The rugged and tough


stainless steel K housing,
with its bolt-in mounting
design feature, actually
becomes an extension of
the cylinder. Its compact
size is ideal for cramped
conditions.

Applications:
Hydraulic Cylinder

Primary/Wood
Mobile
Mining
Valve Control
Food Processing
Off-shore
Waste water

Features:
Bolt-in design

Pulp and paper

Rugged all stainless


steel housing
Designed for
demanding applications
Eliminates need for
protective covers
Pressure rated 8700 psi

General Specifications...pg. 32
Electrical Options...pgs. 33-34
Accessories...pgs. 35-36
Installation Guidelines...pg. 36
Wiring Diagrams...pg. 37
How to order...pg. 38

BTL

Outputs
- Analog (voltage or current)
- Digital start/stop
- Pulse with modulates (PWM)
- PWM with recirculations
- SSI
Length 2 to 156
Quick disconnect and
cable out

www.balluff.com 1-800-543-8390

31

Micropulse
K Style

Dimensions
General Specifications

K Compact, Bolt-in Rod Style


K Style
51mm (2 in) to 3962mm (156 in)
Analog, Digital Pulse, SSI

Series
Available lengths
Output signals

34

400.5

Nominal stroke = measuring area

60

O10.2

O18h6

30

M4x4/6 threaded
blind hole,
security disk
O 9 DIN 6799

25
O64
O79

Connector Clearance

Mounting Surface

Cable Clearance

Mounting Hole Detail (6x)


28

6
118

O6.4

120

O6.4

0117A044

Ordering Code
Measurement type
Measurement range
Shock rating
Vibration rating
Environmental protection
Housing material
Rod & flange material
Pressure rating (rod)
Operating temperature
Storage temperature
Humidity
Connection type
Noise immunity
Approvals
Accessories:
Magnets are on page 35
Float magnets are on page 35
Connectors are on page 36
(Additional connectors start on
page 85)

32

BTL-5-__-M___-K-____(see ordering code on page 38)


Linear displacement
51mm (2 in) to 3962mm (156 in)
100g for 6ms (100g for 2ms continuous) per IEC 68 2-27
12g, 10 to 2000 Hz per IEC 68-2-6
IP 67, IP68 for cable out
316 stainless steel
Tube: 316T stainless, flange: 1316L
600 bar (8700 PSI) max
-40 to + 1850 F
-40 to + 2120 F
<90% non-condensing
connector or integral cable
ESD, RFI and BURST per IEC 1000-4-2/3/4/6, severity level 3
CE
Warning:
These products are not rated for safety applications.

1-800-543-8390 www.balluff.com

Micropulse
K Style
Analog
Voltage
A, B, G

Analog
Current
E,C

Digital
Start/Stop & PWM
P, M, I, L, K

Output

0...+10V,-5...+5V,-10...+10V

0...20 mA, 4...20 mA

Output load
Resolution
Non-linearity

>2KW (5 mA max)
0.1 mV
+
100mm to 500mm stroke,
+
0.02 % over 500mm stroke
Resolution/ min 2m
4m
500 Hz stroke >2000mm
1KHz stroke <2000mm
[150 V/ C +
(5ppm/C*P*V/NL)] * DT
24 Vdc +20% or
15 Vdc +2%
<150mA
(at 1K Hz sampling rate)

500W
0.2A
+100mm to 500mm stroke,
+0.02 % over 50 mm stroke
Resolution/ min 2m
4m
500 Hz stroke >2000mm
1KHz stroke <2000mm
[0.6A/C +
(10 ppm/C*P*V/NL)] * DT
24 Vdc +20% or
15 Vdc +2%
<150mA
(at 1K Hz sampling rate)

Start/Stop or Pulse-widthmodulated (RS422/RS485)


per spec
Controller dependent
+100mm to 500mm stroke,
+
0.02 % over 500mm stroke
Resolution/ min 2m
4m
500 Hz stroe >200 mm
1KHz stroke <2000mm
[0.6A/C +
(10 ppm/C*P*V/NL)] * DT
24 Vdc +20% or
15 Vdc +2%
<150mA
(at 1K Hz sampling rate)

Temperature coefficient*
Operating voltage
Operating current

Notes:
Analog voltage output
versions incorporate both
rising and falling outputs.
Analog current version must
be ordered as rising or
falling ouputs.

Output Options

*Temperature coefficient
variables:
V = output range in V
I = output range in [mA]
DT = temperature change
P = magnet position

Ordering Code

0...10V

-5...+5V

-10...+10V

4...20mA

0...20mA

Start/Stop

Trailing-edge active

Start/Stop

Leading-edge active

Start/Stop
Trailing-edge, tri-state

BTL

High Z

Gate Pulse

I
L&R

PWM

Stop Pulse

Digital Outputs

Repeatability
Hysteresis
Sampling rate

Analog Outputs

Electrical interface
Electrical type
Part No. Code

Electrical Options

Leading-edge active

Active Stroke
0117A045

Analog and Digital Output Options for the Micropulse K Style

RS 485 Signal transmission with digital outputs

www.balluff.com 1-800-543-8390

33

Micropulse
K Style

Specialized Interfaces

Electrical Options
SSI

The SSI (synchronous serial interface)


output interfaces with popular control
systems from manufacturers such as
Allen-Bradley, Delta Computer,
Siemens, Parker and many others.
Cable spans can be up to 400m with
noise free operation. The internal
linearization of this interface make it
ideal for applications requiring the
best accuracy available.
S

Ordering Code
Resolution
Non-linearity
Repeatablity (resolution +
hysteresis)
Hysteresis
Sampling rate
Temperature coefficient *
Communication speeds
Output modes
Operating voltage
Operating current
Output
Output load
Notes:
SSI Maximum cable lengths
Cable length
Clock Freq.
<25 m
<1000 kHz
<50 m
<500 kHz
<100 m
<400 kHz
<200 m
<200 kHz
<400 m
<100 kHz

1, 5, 10, 20 or 40m
30m or 2LSBs, whichever is greater
1 digit
1 digit
500S
(6m + 5ppm xL)/C
100, 200, 400, 500, 1000 kHz
24 or 25 bits
24 Vdc 20%
80 mA
Standard RS-485/422 levels
> 2KW (5 mA max)
Pulse sequence
1

2
t

23

24

tv
out of
range

tm
MSB

LSB

BTL5-S1_ _-Mxxxx-K-____
Connection Type
S 32 = Connector
KA02 = 2m PUR cable
KA05 = 5m PUR cable
KA10 = 10m PUR cable
KA15 = 15m PUR cable
System Resolution
1 = 1m
2 = 5m
3 = 10m
4 = 20m
5 = 40m
Coding
0 = Binary code, rising (24 bits)
1 = Gray code, rising (24 bits)
6 = Binary code, rising (25 bits)
7 = Gray code, rising (25 bits)
Stroke Length
xxxx = length in mm
(see chart on page 38)

34

1-800-543-8390 www.balluff.com

Micropulse
K Style
Product
Type

Magnet
32 ring

Magnet
32 open ring

Magnet
25 ring

Accessories
Magnets & Floats
Magnet
22 ring

BTL

Ordering Code
Material
Weight
Magnet speed
Operating/storage
temperature

Product
Type

Ordering Code
Material
Weight
Operating/storage
temperature
Water displacement
Pressure (static)

BTL-Z-P-1013-4R

BTL-Z-P-1013-4S

BTL-Z-P-1012-4R

BTL-Z-P-1014-2R

AL
12g
any
-40+100C

AL
12g
any
-40+100C

AL
12g
any
-40+100C

AL
10g
any
-40+100C

Magnet
Barrel float

Magnet
Barrel float

Magnet
Bullet float

Magnet
Sphere float

BTL2-S-3212-4Z

BTL2-S-4414-4Z

BTL2-S-6216-8P

BTL2-S-5113-4K

Stainless 316
20g
-40+120C

Stainless 316
35g
-40+120C

Stainless 316
66g
-40+120C

Stainless 316
34g
-40+120C

35mm
24 bar

30mm
20 bar

41mm
15 bar

26mm
40 bar

www.balluff.com 1-800-543-8390

35

Micropulse
K Style

Accessories & Installation

Product
Type

Ordering Code
Material
Contact surface
Solder connection
Cable
Cable diameter
Cable material
Environmental rating
For additional connectors,
see page 85

Straight Connector
S32

Right-angle Connector
S32

BKS-S 32M-____

BKS-S 33M-____

CuZn, nickel plated


0.8m Au
7 x 0.25mm2/AWG 24
68mm
PVC (PUR optional)
IP67 (when installed)

CuZn, nickel plated


0.8m Au
7 x 0.25mm2/AWG 24
68mm
PVC (PUR optional)
IP67 (when installed)

Indicate cable length in ordering code


(consult factory for longer lengths)
00 = connector only
02 = 2 meter cable
05 = 5 meter cable

Installation
The Micropulse transducer has 6
mounting holes for cylinder head
screws (ISO 4762 M618 A2-70).
We recommend installing in nonmagnetizable materials. If using
magnetizable material, installation
must be done as shown below.
Sealing is at the flange mounting
surface using a supplied 15.4 2.1
O-ring.

for magnetizable material


for non-magnetizable
material
a Spacer made of
non-magnetizable material
b Magnet

36

1-800-543-8390 www.balluff.com

Micropulse
K Style

Wiring Diagrams

Analog Wiring Diagrams

Connector

Analog Voltage
15 V (A, B, G)

Analog Voltage
24 V (A, B, G)
2

4
1
View of mating
connector, wiring side
6

PK

GN

GY

Analog output, rising


Analog common

BN

BU

+24 V

WH

Analog output, falling

GND
GND

PK

GN

GY

Analog output, rising


Analog common

BN

BU

+15 V

WH

Analog output, falling

GND
-15 V

0117a022

0117a021

Analog Current
15 V (E, C)

Analog Current
24 V (E, C)

Cable out

YE

GY

Analog output
Analog common

BN

+24 V

BU

WH

GND
GND

YE

GY

Analog output
Analog common

BN

BU

+ 15 V

WH

BTL

GND
-15 V

0117a024

0117a023

Digital Wiring Diagrams


Digital, RS485 differential
24 V (P, M, I, K, L, R)
7

Connector

2
4

1
View of mating
connector, wiring side

YE

PK

GY

GN

BN

BU

WH

Interrogate + Input

Digital, Single-ended
24 V (N)

Interrogate - Input

YE

Pulse + Output

GY

Pulse + Output

BN

BU

+24 V

WH

Pulse - Output
+24 V
GND
GND

0117a025

Interrogate + Input

GND
GND

0117a026

Digital, RS485 differential


15 V (P, M, I, K, L, R)

Cable out

YE

PK

GY

GN

BN

BU

WH

Digital, Single-ended
15 V (N)

Interrogate + Input
Interrogate - Input
Pulse + Output
Pulse - Output
+15 V
GND
-15 V

YE

GY

Pulse + Output

BN

BU

+15 V

WH

Interrogate + Input

GND
- 15 V

0117a028

0117a027

SSI Wiring Diagram


SSI (S)
7

Connector

2
6

1
View of mating
connector, wiring side

Cable out

YE

PK

GY

GN

BN

BU

+Clk
-Clk
+Data
-Data
+24 V
GND

0117a029

* Pin-8 (WH) must remain unconnected

Note:

= twisted-pair

www.balluff.com 1-800-543-8390

37

Micropulse
K Style

Ordering Code
1

9 10

11 12 13 14 15 16 17 18 19 20 21 22 23 24

Balluff - Linear Transducer


Generation 5
Output Type
A=
B=
C=
E=
G=
S=

0 to 10Vdc
-5 to +5Vdc
0 to 20 mA
4 to 20 mA
-10 to +10 Vdc
SSI*

I = Differential start/stop with tri-state


K = Differential stop - leading edge active
L = Differential pulse-width modulated
M= Differential start/stop - leading edge active
N = Single ended start/stop - leading edge active
P = Differential start/stop - trailing edge active
R = Differential pulse-width - recirculated

Supply Voltage
1 = 24 Vdc 20%
2 = 15 Vdc 2% (Not available for S, T or H outputs)
Analog Output Operation
(Leave Blank for Digital Versions)
Voltage type (Output type A, B & G)
1 = User selectable rising or falling
Current type (Output type C & E)
0 = Minimum output at connector end (rising towards opposite end)
7 = Maximum output at connector end (falling towards opposite end)
Normal Stroke Length
0 3 0 5 = 305mm active stroke
Housing Type
K = Compact, bolt-in rod style

Connection Type
S

K A

2 = 8-pin quick disconnect metal connector


0 5

= Cable out (5m standard; specify length in meters)

Interrogation (only valid if output type= R, otherwise leave blank


I = Internal interrogation, E = External interrogation
Recirculation (only valid if output type= R, otherwise leave blank)
1=1 circulation, 2 = 2 circulations, 4 = 4 circulations, 8 = 8 circulations, 16 = 16 circulations
*See additional ordering
information on page 34

Standard Stroke Lengths (consult factory for additional lengths)


inches
2
3
3.5
4
5
6
7
8
9

38

mm
0051
0077
0090
0102
0127
0152
0178
0203
0230

inches
10
11
12
13
15
16
18
20
22

mm
0254
0280
0305
0330
0381
0407
0457
0508
0560

inches
24
26
28
30
32
36
40
42
48

mm
0610
0661
0711
0762
0813
0914
1016
1067
1220

inches
50
54
60
66
69
72
78
84
89

mm
1270
1372
1524
1676
1753
1829
1981
2134
2261

inches
98
108
118
126
140
144
148
152
156

mm
2490
2743
2997
3200
3556
3658
3759
3860
3962

1-800-543-8390 www.balluff.com

Micropulse
Ex

Explosion-Proof

FM

Valve

Approvals:
FM- Class I Div 1,
Group A,B,C,D
FM - Class II div 1,
Group E,F,G
CENELEC - II 2 G Ex
d IIC T6 IP68

Applications:
Liquid level
measurement
Turbine applications
Grain elevator
Petroleum
applications
Mining
Paint manufacturing
Valve control

General Specifications...pg. 42
Electrical Options...pg. 43
Accessories...pg. 44
How to order...pg. 45

FM

a higher level of resistance


to shock and vibration.
Inherently accurate, the
Micropulse Ex features
resolution to <2m and
linearity of +0.02%.

Ex

BTL

Micropulse Ex transducer
packs years of Micropulse
refinements into a selfcontained, stainless steel
housing rated IP68.
Micropulse Ex meets FM
and CENELEC approvals,
eliminating the need for
intrinsically safe barriers.

FM

Micropulse Ex transducers
incorporate some of the most
advanced features found in
any magnetostrictive linear
transducer. Patented
auto-tuning electronics help
reduce maintenance and
repair cost. Auto-tuning also
compensates for any
performance changes
caused by temperature
fluctuations, allowing the
Micropulse to provide
consistent, stable accuracy
over a temperature range
of -40 to 185oF. Enhanced
wave-guide material provides

Features:
Meets the highest FM
and CENELEC approvals
Eliminates the need
for IS barriers
Completely selfcontained unit
Solid stainless steel
housing sealed to
IP68 standards
Operates from
24Vdc or 15Vdc
Analog or digital output
options interface with
any control system

Obtaining position feedback


or liquid level information is a
critical part of many
automation processes.
Without accurate, reliable
measurement feedback,
quality and productivity suffer.
The Micropulse line of
linear transducers has been
providing accurate and
reliable linear measurement
for years. Now with the
Micropulse Ex, this proven
measurement technology is
available for use in the most
hazardous locations.

Introduction

Cylinder

Liquid Level

www.balluff.com 1-800-543-8390

41

Micropulse
Ex

Dimensions
General Specifications

Series
Approvals
Output signals

Explosion Proof
FM - Class 1 Div 1, Group A, B, C, D
Analog & Digital Pulse

Damping Zone
(unusable area)
77

96.8
Active Stroke

50.8

88.9
25.0

87.3

10.2

4.0 Dia

18 h6

47.6

Rod end
(threaded hole M4x6)

Magnet ring

Magnet ring

M20x1.5-6G (cable inlet)


76.2 Dia

Hex Wrench
5/32

30

*Rigid conduit adapter available.


See page 44

Ordering Code
Measurement type
Measurement range
Shock rating
Vibration rating
Environmental protection
Housing material
Pressure rating (rod)
Operating temperature
Storage temperature
Humidity
Connection type
Compatible magnets
Approvals

Rigid conduit adapter


must be ordered separately.

42

15/16 or 24mm
wrench

6.7 Dia (6x)

View A-A

0012A005

BTL-5-__-____-J-DEXC-KL20 (see page 45)


Linear displacement
51mm (2 in) to 3556mm (140 in)
100g for 6ms (100g for 2ms continuous) per IEC 68 2-27
12g, 10 to 2000 Hz per IEC 68-2-6
IP68
316 stainless steel
600 bar (8700 PSI) max
-40 to + 1850 F
-40 to + 2120 F
<90% non-condensing
Terminal blocks via rigid conduit (see accessories for approved conduit adapter)
See accessories
FM - Class I Div 1, Groups A,B,C,D
Class II Div 1 Groups E,F,G
CENELEC - II 2 Eex d IIC T6 IP68
Warning:
Proper installation of the Micropulse Ex is essential. All installation instructions
and precautions are outlined in the Micropulse Ex manual, provided with every unit.

1-800-543-8390 www.balluff.com

Micropulse
Ex
Electrical interface
Electrical type
Part No. Code

Repeatability
(resolution + hystersis)
Hysteresis
Sampling rate
Termperature
coefficient*
Operating voltage
Operating current

Analog
Current
E,C

Digital
Start/Stop & PWM
P, M, I, L,K, N

0...+10V,-5...+5V,-10...+10V

0...20 mA, 4...20 mA

>2KW (5 mA max)
0.1mV
+100m to 500mm stroke,
+0.02 % over 500mm stroke
0.5 mV or 5m
(whichever is greater)
<4m
500 Hz stroke >2000mm
1000 Hz stroke <2000mm
[150V/C +
(5 ppm/C*P*V/NL)]* DT
24 Vdc +20% or 15 Vdc +2%
<150mA
(at 1K Hz sampling rate)

500W
0.2A
+100m to 500mm stroke,
+
0.02 % over 500mm stroke
0.5 mV or 5m
(whichever is greater)
<4m
500 Hz stroke >2000mm
1000 Hz stroke <2000mm
[0.6A/C +
(10 ppm/C*P*V/NL)]* DT
24 Vdc +20% or 15 Vdc +2%
<150mA
(at 1K Hz sampling rate)

RS422/RS485 Compatible
START/STOP or PWM
>per spec
Controller dependent
+
100m to 500mm stroke,
+0.02 % over 500mm stroke
0.5 mV or 5m
(whichever is greater)
<4m
500 Hz stroke >2000mm
1000 Hz stroke <2000mm
(6m + 5ppm
*stroke length)/C
24 Vdc +20% or 15 Vdc +2%
<150mA
(at 1K Hz sampling rate)

Notes:
Analog voltage output versions
incorporate both rising and falling
outputs. Analog current version must
be ordered as rising or falling ouputs.
*Temperature coefficient variables:
V = output range in V
DI = output range in ma
T = temperature change
P = magnet position

Output Options

Ordering Code

0...10V

-5...+5V

-10...+10V

4...20mA

0...20mA

Start/Stop

Trailing-edge active

Start/Stop

Leading-edge active

Start/Stop
Trailing-edge, tri-state

Ex

BTL

High Z

Gate Pulse

I
L

PWM

Stop Pulse

Digital Outputs

Output load
Resolution
Non-linearity

Analog
Voltage
A, B, G

Analog Outputs

Output

Electrical Options

Leading-edge active

Active Stroke
0012A003

Output options for the Micropulse Ex

RS-485 signal transmission with digital outputs

www.balluff.com 1-800-543-8390

43

Micropulse
Ex

Accessories
Ex rated float magnet
Sphere

Ordering Code
Minimum density
Immersion depth in 1
g/cm3 (H20)
Immersion depth in 0.7
g/cm3
Material

BTL-2-S-5113-4K-EX

BTL-2-S-6216-4K-EX

BTL-2-S-4414-4Z01-EX

BTL-2-S-4414-4Z-EX

0.7 g/cm3
26

0.6 g/cm3
41

0.85 g/cm3
45

0.7 g/cm3
30

40

57

sinks

39

Stainless 316

Stainless 316

Stainless 316

Stainless 316

0012A007

0012A008

0012A007

Ex rated float magnet


Barrel

32 ring

32 open ring

25 ring

magnet

Adapter
rigid conduit adapter

BTL-Z-P-1013-4R

BTL-Z-P-1013-4S

BTL-Z-P-1012-4R

BTL-5-EXP-PROOF-ADAPTER

Aluminum

Aluminum

Aluminum

Stainless 303

magnet

magnet

0012A010

Product
Type

Ex rated float magnet


Barrel

Ex rated float magnet


Bullet

0012A009

Product
Type

Ordering Code
Material

44

1-800-543-8390 www.balluff.com

Micropulse
Ex
1

10 11 12 13
-

Ordering Code

14 15 16 17 18 19
0

20 21 22 23 24 25 26 27
E

Balluff - Transducer - Linear


Generation 5
Output
A = 0 to 10Vdc
B = -5 to +5Vdc
C = 0 to 20 mA
E = 4 to 20 mA
G = -10 to +10 Vdc

I = Differential start/stop with tri-state


K = Differential stop - leading edge active
L = Differential pulse-width modulated
M = Differential start/stop - leading edge active
P = Differential start/stop - trailing edge active

Supply Voltage
1 = +24 V DC ( 20%), 2 = 15 Vdc ( 2%)

Ex

BTL

Output Signal
(Leave blank for digital)
1 = increasing and decreasing (voltage output only)
0 = increasing only (current output)
7 = decreasing only (current output)
Stroke Length (in millimeters)
see table of standard lengths
Housing Style
J = Rod Style, Smooth Flange, O-ring seal
Rating Code
DEX = Explosion-Proof - Class 1 Div 1, Groups A,B,C,D & C = Float-Plug rod-end
Electrical Connection Style

0 = M20 threaded hole (see accessories on previous page)


Rigid conduit adapter available,
see accessories on page 44

Standard Stroke Lengths (consult factory for additional lengths)


inches
2
3
3.5
4
5
6
7
8
9

mm
0051
0076
0090
0102
0127
0152
0178
0203
0230

inches
10
11
12
13
15
16
18
20
22

mm
0254
0280
0305
0330
0381
0407
0457
0508
0560

www.balluff.com 1-800-543-8390

inches
24
26
28
30
32
36
40
42
48

mm
0610
0661
0711
0762
0813
0914
1016
1067
1220

inches
50
54
60
66
69
72
78
84
89

mm
1270
1372
1524
1676
1753
1829
1981
2134
2261

inches
98
108
118
126
140

mm
2490
2743
2997
3200
3556

45

Micropulse
E Style

Embeddable Rod Style

The unique E housing


offers the ability to mount
the electronics away from
the pressure tube. This
allows the electronics to
be placed in a safe,
out-of-the way area where
space is an issue. This
remote mounting feature
facilitates easy access to
the electronics without
removing the pressure
tube from the cylinder.

Introduction

Applications:
Hydraulic cylinder

Presses
Mobile

Features:
Space saving embeddable
design
Designed for use in hydraulic
cylinders
Field replaceable electronics
module
Analog, digital and SSI
outputs
2 to 156

General Specifications...pg. 48
Electrical Options...pg. 49
Accessories...pg. 50
Wiring Diagrams...pg. 51
How to order...pg. 52

Cylinder cap
Electronics head

BTL

Rod

Embeddable Micropulse transducer


installed in a cylinder cap

www.balluff.com 1-800-543-8390

47

Micropulse
E Style

Dimensions
General Specifications

E Embeddable Rod Style


E Style
51mm (2 in) to 3962mm (156 in)
Analog & Digital Pulse

Series
Available lengths
Output signals

Nominal stroke
measuring area

43
Null Zone

60

O25

O10.2

32

O2

Rod End
threaded M4x6 hole

254

46

M4x0.7 (2x)

39

69

29

A
Interface

48

A (mm)
Digital

57

Analog

74

0117A050

Ordering Code, Electronics Head


Ordering Code, Rod
Measurement type
Measurement range
Shock rating
Vibration rating
Environmental protection
Housing material (pressure tube)
Housing material (electronics head)
Pressure rating (rod)
Operating temperature
Storage temperature
Humidity
Connection type
Noise immunity
Approvals
Accessories:
Magnets are on page 50
Float magnets are on page 50
Connectors start on page 85

BTL-5-____-E1-A-S32/KA05 (Electronics Head--see page 53)


BTL-5-000-M____-E1-A254 (Rod--see page 53)
Linear displacement
51mm (2 in) to 3962mm (156 in)
100g for 6ms (100g for 2ms continuous) per IEC 68 2-27
12g, 10 to 2000 Hz per IEC 68-2-6
IP 67 (when BKS-S32/33 is installed)
316 stainless steel
anodized aluminum/314L stainless steel
400 bar (5800 PSI) max
-40 to + 1850 F
-40 to + 2120 F
<90% non-condensing
connector or integral cable
ESD, RFI and BURST per IEC 1000-4-2/3/4/6, severity level 3
CE
Warning:
These products are not rated for safety applications.

Calibration device BTL-5-A-EH01

48

1-800-543-8390 www.balluff.com

Micropulse
E Style

Analog
Voltage
A, B, G

Analog
Current
E,C

Digital
Start/Stop & PWM
P, M, I, L, K

0...+10V,-5...+5V,-10...+10V

0...20 mA, 4...20 mA

Output load
Resolution
Non-linearity

>2KW (5 mA max)
0.33 mV
2KHz

500W
0.66 A
2KHz

Repeatability
Hysteresis
Sampling rate

Resolution/ min 2 m
5 m
500 Hz stroke >2000mm
1KHz stroke <2000mm
[150 V/ C +
(5ppm/C*P*V/NL)] * DT
24 Vdc +20% or
15 Vdc +2%
<150 mA
(at 1K Hz sampling rate)

Resolution/ min 2 m
5 m
500 Hz stroke >2000mm
1KHz stroke <2000mm
[0.6 A/C +
(10 ppm/C*P*V/NL)] * DT
24 Vdc +20% or
15 Vdc +2%
<150 mA
(at 1K Hz sampling rate)

Start/Stop or Pulse-widthmodulated (RS422/RS485)


per spec
Controller dependent
+100mm to 500mm stroke,
+0.02 % over 500mm stroke
Resolution/ min 2 m
5 m
500 Hz stroke >2000mm
1KHz stroke <2000mm
[0.6 A/C +
(10 ppm/C*P*V/NL)] * DT
24 Vdc +20% or
15 Vdc +2%
<150 mA
(at 1K Hz sampling rate)

Temperature coefficient*
Operating voltage
Operating current

Notes:
Analog voltage output
versions incorporate both
rising and falling outputs.
Analog current version must
be ordered as rising or
falling ouputs.
*Temperature coefficient
variables:
V = output range in V
I = output range in [mA]
DT = temperature change
P = magnet position

Output Options

Ordering Code

0...10V

-5...+5V

-10...+10V

4...20mA

0...20mA

Start/Stop

Trailing-edge active

Start/Stop

Leading-edge active

Start/Stop
Trailing-edge, tri-state

High Z

Gate Pulse

I
L&R

PWM

Stop Pulse

Leading-edge active

0117A051

BTL

Digital Outputs

Output

Analog Outputs

Electrical interface
Electrical type
Part No. Code

Electrical Options

Active Stroke

Analog and Digital Output Options for the Micropulse E Style

RS-485 signal transmission with digital outputs

www.balluff.com 1-800-543-8390

49

Micropulse
E Style
Product
Type

Ordering Code
Material
Weight
Magnet speed
Operating/storage
temperature

Product
Type

Ordering Code
Material
Weight
Operating/storage
temperature
Water displacement
Pressure (static)

50

Accessories
Magnets & Floats
Magnet
32 ring

Magnet
32 open ring

Magnet
25 ring

Magnet
22 ring

BTL-Z-P-1013-4R

BTL-Z-P-1013-4S

BTL-Z-P-1012-4R

BTL-Z-P-1014-2R

AL
12g
any
-40+100C

AL
12g
any
-40+100C

AL
12g
any
-40+100C

AL
10g
any
-40+100C

Magnet
Barrel float

Magnet
Barrel float

Magnet
Bullet float

Magnet
Sphere float

BTL2-S-3212-4Z

BTL2-S-4414-4Z

BTL2-S-6216-8P

BTL2-S-5113-4K

Stainless 316
20g
-40+120C

Stainless 316
35g
-40+120C

Stainless 316
66g
-40+120C

Stainless 316
34g
-40+120C

35mm
24 bar

30mm
20 bar

41mm
15 bar

26mm
40 bar

1-800-543-8390 www.balluff.com

Micropulse
E Style

Wiring Diagrams

Analog Wiring Diagrams


Analog Voltage
24 V (A, B, G)

2
4

1
View of mating
connector, wiring side

PK

GN

GY

Analog output, rising


Analog common

BN

BU

WH

Analog Voltage
15 V (A, B, G)

Analog output, falling

PK

GN

+24 V

GY

Analog output, rising


Analog common

GND
GND

BN

BU

+15 V

WH

0117a021

Analog output, falling

GND
-15 V

0117a022

Analog Current
24 V (E, C)

Connector

Cable out

YE

GY

Analog output
Analog common

BN

BU

+24 V

WH

Analog Current
15 V (E, C)

GND
GND

YE

GY

Analog output
Analog common

BN

BU

+ 15 V

WH

0117a023

GND
-15 V

0117a024

Digital Wiring Diagrams


Digital, RS485 differential
24 V (P, M, I, K, L, R)
7
8

5
2

4
1
View of mating
connector, wiring side
6

YE

PK

GY

GN

BN

BU

WH

Digital, Single-ended
24 V (N)

Interrogate + Input
Interrogate - Input
Pulse + Output
Pulse - Output
+24 V
GND
GND

0117a025

BTL

YE

Interrogate + Input

GY

Pulse + Output

BN

BU

+24 V

WH

GND
GND

0117a026

Digital, RS485 differential


15 V (P, M, I, K, L, R)
1

YE

PK

GY

GN

BN

BU

WH

0117a027

Digital, Single-ended
15 V (N)

Interrogate + Input
Interrogate - Input
Pulse + Output

YE

Pulse - Output

GY

Pulse + Output

+15 V

BN

GND

BU

+15 V

-15 V

WH

Interrogate + Input

GND
- 15 V

0117a028

www.balluff.com 1-800-543-8390

51

Micropulse
E Style

Ordering Code

Electronics Head

7
A

10 11 12 13 14 15 16 17 18 19 20 21
-

Balluff - Linear Transducer


Generation 5
Output Type
A = 0 to 10Vdc
B = -5 to +5Vdc
C = 0 to 20 mA
E = 4 to 20 mA
G = -10 to +10 Vdc

I = Differential start/stop with tri-state


K = Differential stop - leading edge active
L = Differential pulse-width modulated
M= Differential start/stop - leading edge active
N = Single ended start/stop - leading edge active
P = Differential start/stop - trailing edge active
R = Differential pulse-width - recirculated

Supply Voltage
1 = 24 Vdc 20%
Analog Output Operation (blank for digital)
Voltage type (A, B & G): 1= User selectable rising or falling
Current type (C & E): 0 = Minimum output at connector
7 = Maximum output at connector
Embeddable
Connection Type
S 3 2 = 8-pin quick disconnect metal connector
K A

0 5 = Integral cable (5m standard; specify length in meters)

Interrogation (only valid if output type= R, otherwise leave blank)


I = Internal interrogation, E = External interrogation
Recirculation (only valid if output type= R, otherwise leave blank)
1=1 circulation, 2 = 2 circulations, 4 = 4 circulations, 8 = 8 circulations, 16 = 16 circulations

Rod

10 11 12 13 14 15 16 17 18 19 20 21 22 23

Balluff - Linear Transducer


Generation 5
Nominal Stroke length
0 3 0 5 = 305mm active stroke (see table of standard lengths below)
Embeddable
Connector/Cable
A254 = Push-lock connector with 254mm integral cable
Standard Stroke Lengths (consult factory for additional lengths)
inches
2
3
3.5
4
5
6
7
8
9

52

mm
0051
0077
0090
0102
0127
0152
0178
0203
0230

inches
10
11
12
13
15
16
18
20
22

mm
0254
0280
0305
0330
0381
0407
0457
0508
0560

inches
24
26
28
30
32
36
40
42
48

mm
0610
0661
0711
0762
0813
0914
1016
1067
1220

inches
50
54
60
66
69
72
78
84
89

mm
1270
1372
1524
1676
1753
1829
1981
2134
2261

inches
98
108
118
126
140
144
148
152
156

mm
2490
2743
2997
3200
3556
3658
3759
3860
3962

1-800-543-8390 www.balluff.com

Profile Style
Balluff Micropulse
Transducers in the Profile
housing with their
unique design, high
protection rating, and ease
of installation, are an ideal
alternative to linear
Transducers such as
potentiometers, glass scales
and LVDTs.

Features/Advantages:
Non-contact absolute
position feedback
IP67, highly resistant to
contamination
Wear free

High immunity to shock


and vibration

Direct replacement of
lower grade linear feed
back devices

Captive and floating


magnet

Metal saw

Digital Pulse
SSI
Can Open
Profibus

Introduction

Film slitting
machine

Applications:
Balluff transducers offer
features which assure
reliable operation in many
areas of automation and
process technology, even
under extreme ambient
conditions:

Outputs:
Analog

Micropulse
P Style

Hydraulic press

Mechanical
eccentric press

Hydraulic cylinders
Tooling and tool handling
Presses
Casting and rolling mills
Foundries
Injection molding
Leveling machines
Transport systems
Lift controls
Level monitoring
Tunnel boring
equipment
Die casting
machinery
Portal robots

Dosimetry and mixing unit

General Specifications...pg. 56
Electrical Options...pgs. 57-59
Magnets...pgs. 61-62
Accessories...pg. 63
Wiring Diagrams...pg. 64
How to order...pg. 65

BTL

Woodworking
machinery
Flight simulators
Cutting/slitting
machinery
Conveying
Packaging
machines
Windmills

Elevators
Forestry

www.balluff.com 1-800-543-8390

55

Micropulse
P Style

Dimensions
General Specifications

P Standard Rod Style

Series
Available lengths
Output signals

P Style
51mm (2 in) to 3962mm (156 in)
Analog, Digital Pulse, SSI, CANopen, Profibus
Installation Length
A

73

Nominal stroke

37

41
12
1

15

50
68

M5x22 ISO 4762

Interface

0117A021

A (mm)

B (mm)

C (mm)

Analog, Digital
SSI

73

62

42

CANopen

73

57

Profibus
3 connectors

106

70 3

Profibus
1 connector

106

65 3

BTL-5-__-M___-P-____(see ordering code on page 65)

Ordering Code

Linear displacement
51mm (2 in) to 3962 mm (156 in)
100g for 6ms (100g for 2ms continuous) per IEC 68 2-27
12g, 10 to 2000 Hz per IEC 68-2-6
IP 67 (when BKS-S32/33 is installed)
anodized aluminum
-40 to + 1850 F
-40 to + 2120 F
<90% non-condensing
connector or integral cable
ESD, RFI and BURST per IEC 1000-4-2/3/4/6, severity level 3
CE

Measurement type
Measurement range
Shock rating
Vibration rating
Environmental protection
Housing material
Operating temperature
Storage temperature
Humidity
Connection type
Noise immunity
Approvals

Accessories:
Warning:
Magnets are on pages 61-62 These products are not rated for safety applications.
Connectors start on page on
page 85

20
14

PL0010B

37 5 9

27
35

Additional mounting dimensions

56

1-800-543-8390 www.balluff.com

Micropulse
P Style
Analog
Voltage
A, B, G

Analog
Current
E,C

Digital
Start/Stop & PWM
P, M, I, L, K

Output

0...+10V,-5...+5V,-10...+10V

0...20 mA, 4...20 mA

Output load
Resolution
Non-linearity

>2KW (5 mA max)
<0.1 mV
+100mm to 500mm stroke,
+0.02 % over 500mm stroke
Resolution/ min 2m
4m
500 Hz stroke >2000mm
1KHz stroke <2000mm
[150V/ C +
(5ppm/C*P*V/NL)] * DT
24 Vdc +20% or
15 Vdc +2%
<150mA
(at 1K Hz sampling rate)

>500W
<0.2A
+100mm to 500mm stroke,
+0.02 % over 500mm stroke
Resolution/ min 2m
4m
500 Hz stroke >2000mm
1KHz stroke <200 mm
[0.6A/C +
(10 ppm/C*P*V/NL)] * DT
24 Vdc +20% or
15 Vdc +2%
<150mA
(at 1K Hz sampling rate)

Start/Stop or Pulse-widthmodulated (RS422/RS485)


per spec
Controller dependant
+100mm to 500mm stroke,
+0.02 % over 500mm stroke
Resolution/ min 2m
4m
500 Hz stroke >2000mm
1KHz stroke <2000mm
[0.6A/C +
(10 ppm/C*P*V/NL)] * DT
24 Vdc +20% or
15 Vdc +2%
<150mA
(at 1K Hz sampling rate)

Temperature coefficient*
Operating voltage
Operating current

Notes:
Analog voltage output
versions incorporate both
rising and falling outputs.
Analog current version must
be ordered as rising or
falling ouputs.

Output Options

*Temperature coefficient
variables:
V = output range in V
I = output range in [mA]
DT = temperature change
P = magnet position

Ordering Code

0...10V

-5...+5V

-10...+10V

4...20mA

0...20mA

Start/Stop

Trailing-edge active

Start/Stop

Leading-edge active

Start/Stop
Trailing-edge, tri-state

BTL

High Z

Gate Pulse

I
L&R

PWM

Stop Pulse

Digital Outputs

Repeatability
Hysteresis
Sampling rate

Analog Outputs

Electrical interface
Electrical type
Part No. Code

Electrical Options

Leading-edge active

0117A026

Active Stroke

Analog and Digital Output Options for the Micropulse P Style

RS485 signal transmission with digital outputs

www.balluff.com 1-800-543-8390

57

Micropulse
P Style

Ordering Code
Resolution
Non-linearity
Repeatablity (resolution +
hysteresis)
Hysteresis
Sampling rate
Temperature coefficient *
Operating voltage
Operating current
Network isolation
Network speed
Network compatibility
Address selection
Communication types
Configuration software
Number of magnets supported
Notes:
For more technical
information see page 101

Network Options

Electrical Options
CANopen

Profibus

This interface provides an efficient


connection to machines using
CANopen. Features include:
- Process data objects
incorporating position, velocity
and set-point information
- Emergency object for set-points
- Service data objects for
configuring transducer modes
- Synchronization objects for
network wide activities

This interface provides an efficient connection


to machines using Profibus. Features of this
interface include:
- Single telegram message for fast updates
even with 4 magnets
- Operates at 12 Mbps
- GSD file provided to configure telegram
message
- Sync and Freeze functions available for
coordination between other devices

Position 5m, Velocity 0.1mm/s


increments(selectable)
30m at 5m resolution
1 digit

Position 5m (configurable)
Velocity 0.1mm/s increments (configurable)
30m at 5m resolution
1 digit

1 digit
1kHz
(6m + 5ppm x L)/C
24 Vdc 20%
100 mA
yes
10, 20, 50, 100, 125, 250,
500, 800, 1000 kBaud
CiA Standard DS301
Rev. 3.0 (Encoder Profile)
Software
Producer/consumer
none required
1,2 or 4

1 digit
1kHz
(6m + 5ppm x L)/C
24 Vdc 20%
120 mA
yes
9.6, 19.2, 93.7, 187.5,
900, 1500, 1200 kBaud
EN 50170
(Encoder Profile)
DIP switch
Master/Slave
GSD file
1,2 or 4

Data Format

Data Format

Position

Position (1 per magnet)


32-bit integer

32-bit integer

Velocity

Velocity (1 per magnet)

16-bit integer

32-bit integer

Set
points
8-bit integer

BTL5-H1_ _-Mxxxx-P-S92

BTL5-T1___-Mxxxx-P-____

Baud Rate
0 = 1MBaud
1 = 800 kBaud
2 = 500 kBaud
3 = 250 kBaud
4 = 125 kBaud
5 = 100 kBaud
6 = 50 kBaud
7 = 20 kBaud
8 = 10 kBaud
Process Data
1 = 1 x position & 1 x velocity
2 = 2 x position & 2 x velocity
3 = 4 x position
Stroke Length
xxxx = length in mm (see chart on page 65)

58

Connection Type
S 103 = 3 connectors:
Power: 3-pin male, M8
Bus in: 5-pin male, M12
Bus out: 5-pin female, M12
S 86 = 12-pin female
No. of Magnets
1 = 1 magnet
2 = 2 magnets
3 = 4 magnets
Stroke Length
xxxx = length in mm
(see chart on page 65)

1-800-543-8390 www.balluff.com

Micropulse
P Style

Specialized Interface

Electrical Options

SSI
The SSI (synchronous serial interface) output interfaces with
popular control systems from manufacturers such as AllenBradley, Delta Computer, Siemens, Parker and many others.
Cable spans can be up to 400m with noise-free operation.
The internal linearization of this interface makes it ideal for
applications requiring the best accuracy available.

Ordering Code
Resolution
Non-linearity
Repeatablity (resolution + hysteresis)
Hysteresis
Sampling rate
Temperature coefficient *
Communication speeds
Output modes
Operating voltage
Operating current
Output
Output load
Notes:
SSI Maximum cable lengths
Cable length
Clock Freq.
<25 m
<1000 kHz
<50 m
<500 kHz
<100 m
<400 kHz
<200 m
<200 kHz
<400 m
<100 kHz

www.balluff.com 1-800-543-8390

S
1, 5, 10, 20 or 40m
30m or 2LSBs, whichever is greater
1 digit
1 digit
500S
(6m + 5ppm xL)/C
100, 200, 400, 500, 1000 kHz
24 or 25 bits
24 Vdc 20%
80mA
Standard RS-484/422 levels
> 2KW (5 mA max)
Pulse sequence
1

2
t

23

tv
out of
range

BTL

24
tm

MSB

LSB

BTL5-S1_ _-Mxxxx-P-____
Connection Type
S 32 = Connector
KA02 = 2m PUR cable
KA05 = 5m PUR cable
KA10 = 10m PUR cable
KA15 = 15m PUR cable
System Resolution
1 = 1m
2 = 5m
3 = 10m
4 = 20m
5 = 40m
Coding
0 = Binary code, rising (24 bits)
1 = Gray code, rising (24 bits)
6 = Binary code, rising (25 bits)
7 = Gray code, rising (25 bits)
Stroke Length
xxxx = length in mm
(see chart on page 65)

59

Magnets floating
Magnet
BTL Profile

Type

floating

38
28
C

20

9
14

4.2

50 +4

The BTL5-P-3800-2
magnet can be used with a
vertical offset from the
upper surface of the
transducer body of
0...4mm, and the
BTL5-P-5500-2 permits a
distance of 5...15mm. The
BTL5-P-4500-1 is an
electromagnet and requires
a supply voltage of 24V,
which can be turned on and
off for selective activation.
This allows multiplex
operation with multiple
magnets on a single
transducer, since only one
magnet is active at a time.

Description
for Series

Lateral offset:
C = 2mm
Vertical distance
of magnet:
D = 0.1...4mm

Balluff magnets are


available in captive or
floating styles. All BTL5
magnets shown here can
be used on any Balluff
Micropulse transducer.
Maximum resolution and
repeatability are achieved
using BTL5-F/M/N-2814-1S
captive magnets.

50
68

PL0001

Micropulse
P Style

BTL5-P-3800-2

Ordering Code
Housing material
Weight
Magnet traverse speed
Supply voltage
Current draw
Operating temperature/storage temperature
Included

Plastic
approx. 12 g
any

40...+85 C
Magnet
2 mounting screws DIN 84 M435-A2
with washers and nuts

Accessories
(please order separately)

Mounting feet with isolation


washers and screws
ordered separately.
Replacement: 1 each
mounting foot and screws
Type. No.: BTL-5-FEET-STD

60

Transducer
Stroke Length
0051-0457
0508-0711
0762-0914
1016-1220
1270
1524
1778
2032
2286
2540
2794
3048
3302
3606

Number of feet
Factory recommends
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1-800-543-8390 www.balluff.com

Micropulse
P Style

Magnets floating

Magnet
BTL Profile

Magnet
BTL Profile

floating

floating

Lateral offset:
C = 15mm
Vertical distance
of magnet:
D = 5...15mm

Lateral offset:
C = 2mm
Vertical distance
of magnet:
D = 0.1...2mm

BTL5-P-5500-2

BTL5-P-4500-1

Plastic
approx. 40g
any

Plastic
approx. 90g
any
24 V DC
100mA
40...+60 C
Magnet

40...+85 C
Magnet

BTL
Straight connector
C04-AEC-00-VY-050M
Right-angle connector C04-AEC-00-VY-050M

Non-contact!
Vertical offset
0.1...4mm or
5...15mm

Please indicate cable length in ordering code:


03, 05, 10, 15
e.g. 050M = 5M

Connector for Electromagnet

www.balluff.com 1-800-543-8390

61

Micropulse
P Style
Description
for Series
Type

Ordering Code
Material Housing
Slide surface
Weight
Magnet traverse
speed
Operating
temperature/storage
temperature

Magnets captive
Magnet
BTL Profile

Magnet
BTL Profile

Magnet
BTL Profile

Captive

Captive

Captive

BTL5-M-2814-1S

BTL5-N-2814-1S

BTL5-F-2814-1S

Anodized aluminum
Plastic
approx. 32g
any

Anodized aluminum
Plastic
approx. 35g
any

Plastic
Plastic
approx. 28g
any

40...+85 C

40...+85 C

40...+85 C

Mounting feet with isolation


washers and screws
ordered separately.
Replacement: 1 each
mounting foot and screws
Type. No.: BTL-5-FEET-STD

62

Transducer
Stroke Length
0051-0457
0508-0711
0762-0914
1016-1220
1270
1524
1778
2032
2286
2540
2794
3048
3302
3606

Number of feet
Factory recommends
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1-800-543-8390 www.balluff.com

Micropulse
P Style
Product
Compatibility

Control Arm
BTL5-F-2814-1S
BTL5-R-2814-1S

Accessories

Swivel Eye
BTL5-GS08-

Ball Joint
BTL5-GS08-

M5x0.8
36

8
13

41

13

42

22
M5x0.8

10

Ordering Code

0117A043

0117A042

M5x0.8

0117A044

M5x0.8

BLT-5-GS08- _ _ _ _ -A

BTL-5-SWIVEL-EYE

BTL-5-BALL-JOINT

Aluminum
150g/m

Aluminum/steel
14g

Aluminum/steel
11g

Material
Weight

Specify control arm length in mm


e.g. BTL-5-GS08-0305-A

Product
Type

Mounting feet
Narrow

Mounting feet
Standard

7.2

7.2

BTL

15

12.7

12

Ordering Code (one foot)


Material
Weight

www.balluff.com 1-800-543-8390

42.7
57

0117A040

0117A041

9.1

50
68

BTL-5-FEET-NR

BTL-5-FEET-STD

Aluminum
6g

Black Anodized Aluminum


12g

63

Micropulse
P Style

Wiring Diagrams

Analog Wiring Diagrams


3

Analog Voltage
15 V (A, B, G)

Analog Voltage
24 V (A, B, G)
5

4
1
View of mating
connector, wiring side
6

Analog output, falling

PK

GN

GY

Analog output, rising


Analog common

GY

Analog output, rising


Analog common

BN

BN

BU

+15 V

BU

+24 V

WH

PK

GN

GND
GND

WH

Analog output, falling

GND
-15 V

0117a022

0117a021

Analog Current
15 V (E, C)

Analog Current
24 V (E, C)
1

YE

GY

Analog output
Analog common

BN

BU

+24 V

WH

GND
GND

YE

GY

Analog output
Analog common

BN

BU

+ 15 V

WH

GND
-15 V

0117a024

0117a023

Digital Wiring Diagrams


Digital, RS485 differential
24 V (P, M, I, K, L, R)
3

4
1
View of mating
connector, wiring side
6

YE

PK

GY

GN

BN

BU

WH

Digital, Single-ended
24 V (N)

Interrogate + Input

YE

Interrogate + Input

GY

Pulse + Output

Pulse - Output

BN

BU

+24 V

+24 V
GND

WH

Interrogate - Input
Pulse + Output

GND

Digital, Single-ended
15 V (N)

Digital, RS485 differential


15 V (P, M, I, K, L, R)
YE

PK

GY

GN

BN

BU

WH

GND

0117a026

0117a025

GND

Interrogate + Input

YE

Interrogate - Input

GY

Pulse + Output

Pulse + Output

BN

Pulse - Output

BU

+15 V

+15 V

WH

GND
-15 V

Interrogate + Input

GND
- 15 V

0117a028

0117a027

SSI Wiring Diagram

CANopen Wiring Diagram


SSI (S)
3

2
4

1
View of mating
connector, wiring side

YE

PK

GY

GN

BN

BU

+Clk

CANopen (H)

-Clk
+Data
-Data
+24 V
GND

0117a029

* Pin-8 (WH) must remain unconnected

Profibus Wiring Diagram

5
1

4 3

3 4

Power

View of mating
connector, wiring side

Bus In (male)

Bus Out (female)

2 5

0117a034

CAN_GND

+24 V

View of mating
connector, wiring side

GND

0117a030

Profibus Wiring Diagram


2

5 2

CAN_LOW

Profibus (T)
4
1 3

CAN_HIGH

4
3
1

+RxD/TxD-N (A)

1
5
1

VP +5 V (output)

Data GND

VP +5 V (output)

+ 24 V

+RxD/TxD-P (B)
Data GND

+RxD/TxD-P (B)

VP +5 V (output)

+RxD/TxD-N (A)

Data GND
shield

+RxD/TxD-P (B)

5
4

Profibus (T)

+RxD/TxD-N (A)

GND
shield

0117a039

shield
+ 24 V

GND

shield

Note:

= twisted-pair

64

1-800-543-8390 www.balluff.com

Micropulse
P Style
1

8
1

Ordering Code

10 11 12 13 14 15 16 17 18 19 20 21 22

Balluff - Linear Transducer


Generation 5
Output Type
A = 0 to 10Vdc
B = -5 to +5Vdc
C = 0 to 20 mA
E = 4 to 20 mA
G = -10 to +10 Vdc
S = SSI*
T = Profibus*
H = CANopen*

I = Differential start/stop with tri-state


K = Differential stop - leading edge active
L = Differential pulse-width modulated
M= Differential start/stop - leading edge active
N = Single ended start/stop - leading edge active
P = Differential start/stop - trailing edge active

Supply Voltage
1 = 24 Vdc 20%
2 = 15 Vdc 2% (Not available for S, T or H outputs)
Analog Output Operation (blank for digital)
Voltage type (Output type A, B & G)
1 = User selectable rising or falling
Current type (Output type C & E)
0 = Minimum output at connector end (rising towards opposite end)
7 = Maximum output at connector end (falling towards opposite end)

BTL

Normal Stroke Length


0

= 305mm active stroke

Housing Type
P = Standard Profile Housing

Connection Type
S

K A

2 = 8-pin quick disconnect metal connector


0

5 = Cable out (5m standard; specify length in meters)

Standard Stroke Lengths (consult factory for additional lengths)


Electrical Stroke

inches
2
3
4
5
6
7
8
9
10
11
12
13

mm
0051
0077
0102
0127
0152
0178
0203
0230
0254
0280
0305
0330

inches
15
16
18
20
22
24
26
28
30
32
36
40

mm
0381
0407
0457
0508
0560
0610
0661
0711
0762
0813
0914
1016

www.balluff.com 1-800-543-8390

inches
42
48
50
60
70
80
90
100
110
120
130
142

mm
1067
1220
1270
1524
1778
2032
2286
2540
2794
3048
3302
3606

*See additional ordering


information on pages 58-59

inches mm
148
3759
156
3962

65

Micropulse
R Style

R Low-Profile Style
The R housing provides
two unique opportunities in
the Magnetostrictive world
of Position Feedback. The
first is with its unique
housing design; it is able to
go where other products
cant due to size. With its
low profile design of rugged
aluminum, it requires less
space. The other unique
opportunity is BACKPACK
FEEDBACK.

Applications:
Pneumatic glides

Plastic machines
Presses
Transport system
Die casting
Entertainment
Flight simulators
Tool handling
Packaging
Conveying
Measurement
Semiconduction

Features:
Low profile for space
critical applications
Compatible with rod in
cylinder type linear
potentiometers
Cable out or quick
disconnect
Length 2 156

Floating or captive

magnet
Outputs Digital start/
stop, pulse with
modulated PWM, Analog
Voltage or Current
IP67

Backpack Feedback

BackPack Feedback:
Using the R style
transducer, precision
electronic feedback can
now be accomplished
without any modification,
special machining, or
mechanical coupling to the
cylinder rod. For use with
any non-ferrous cylinder
tube, simply mount the R
housing Micropulse
transducer to the cylinder
end caps. Magnetic fields
developed by standard
piston mounted magnets
generate a position signal in
the transducer. Testing
required for approval.

Introduction

No internal modification

to the cylinder is
necessary, i.e. gun
drilling of piston rod
Wear free, noncontact, absolute
positioning
Low profile housing,
ease of fit to cylinder
No threat of air
leakage as with
internal position
transducers
Ease of replacement
without de-pressurizing
the cylinder

BACKPACK

FEEDBACK

General Specifications...pg. 68
Electrical Options...pg. 69
Magnets...pgs. 70-73
Accessories...pg. 74
Wiring Diagrams...pg. 75
How to order...pg. 76

www.balluff.com 1-800-543-8390

BTL

67

Micropulse
R Style

Dimensions
General Specifications

R Low Profile

Series
Available lengths
Output signals

R Style
51mm (2 in) to 3962mm (156 in)
Analog & Digital Pulse
105

5
70

95

Nominal stroke

46
32

12
1

35
15

50
68

Cable out

M5x22 ISO 4762

Connector, straight
15

Connector, right angle

62

42

O7

0117A029

Ordering Code
Measurement type
Measurement range
Shock rating
Vibration rating
Environmental protection
Housing material
Operating temperature
Storage temperature
Humidity
Connection type
Noise immunity
Approvals

BTL-5-__-M___-R-____(see ordering code on page 76 )


Linear displacement
51mm (2 in) to 3962mm (156 in)
100g for 6ms (100g for 2ms continuous) per IEC 68 2-27
12g, 10 to 2000 Hz per IEC 68-2-6
IP 67 (when BKS-S32/33 is installed)
anodized aluminum
-40 to + 1850 F
-40 to + 2120 F
<90% non-condensing
connector or integral cable
ESD, RFI and BURST per IEC 1000-4-2/3/4/6, severity level 3 (4 for BURST)
CE

Accessories:
Warning:
Magnets are on pages 70-73 These products are not rated for safety applications.
Connectors start on page 85

68

1-800-543-8390 www.balluff.com

Micropulse
R Style
Electrical interface
Electrical type
Part No. Code

Electrical Options

Analog
Voltage
A, B, G

Analog
Current
E,C

Digital
Start/Stop & PWM
P, M, I, L, K

Output

0...+10V,-5...+5V,-10...+10V

0...20 mA, 4...20 mA

Output load
Resolution
Non-linearity

>2KW (5 mA max)
0.1mV
+100mm to 500mm stroke,
+0.02 % over 500mm stroke
Resolution/ min 2m
5m
1KHz

500W
0.2A
+100mm to 500mm stroke,
+0.02 % over 500mm stroke
Resolution/ min 2m
5m
1KHz

Start/Stop or Pulse-widthmodulated (RS422/RS485)


per spec
Controller dependent
+100mm to 500mm stroke,
+
0.02 % over 500mm stroke
Resolution/ min 2m
5m
1KHz

[150 V/ C +
(5ppm/C*P*V/NL)] * DT
24 Vdc +20%
150mA

[0.6A/C +
(10 ppm/C*P*V/NL)] * DT
24 Vdc +20%
150mA

[0.6A/C +
(10 ppm/C*P*V/NL)] * DT
24 Vdc +20%
150mA

Operating voltage
Operating current
Notes:
Analog voltage output
versions incorporate both
rising and falling outputs.
Analog current version must
be ordered as rising or
falling ouputs.
*Temperature coefficient
variables:
V = output range in V
I = output range in [mA]
DT = temperature change
P = magnet position

Output Options

Ordering Code

0...10V

-5...+5V

-10...+10V

4...20mA

0...20mA

Start/Stop

Trailing-edge active

Start/Stop

Leading-edge active

Start/Stop
Trailing-edge, tri-state

Gate Pulse

L&R

PWM

Stop Pulse

BTL

Leading-edge active

0117A031

High Z

Digital Outputs

Temperature coefficient*

Analog Outputs

Repeatability
Hysteresis
Sampling rate

Active Stroke

Analog and Digital Output Options for the Micropulse R Style

RS485 Transmission of digital signals

www.balluff.com 1-800-543-8390

69

Magnets floating
Profile series

Balluff magnets are


Description
available in captive or
for Series
floating styles. All BTL5
magnets shown here can Type
be used on any Balluff
Micropulse transducer.
Maximum resolution and
repeatability are achieved
using
BTL5-F/M/N-2814-1S
captive magnets.

Standard, floating
38
28
C

14

20

4.2

28 + 4

The BTL5-P-3800-2
magnet can be used with
a vertical offset from the
upper surface of the
transducer body of 0...4
mm, and the BTL5-P5500-2 permits a
distance of 5...15 mm.
The BTL5-P-4500-1 is an
electromagnet and
requires a supply voltage
of 24V, which can be
turned on and off for
selective activation. This
allows multiplex operation
with multiple magnets on
a single transducer, since
only one magnet is active
at a time.

Magnet
BTL Profile

Micropulse
R Style

50
68

Lateral offset:
C = 2mm

Ordering Code

Vertical distance of magnet:


D= 0.1...4mm

BTL5-P-3800-2

Housing material
Weight
Magnet traverse speed
Supply voltage
Current draw
Operating temperature/storage
temperature
Included

Plastic
approx. 12g
any

40...+85 C
Magnet
2 mounting screws DIN 84 M435-A2
with washers and nuts

Accessories
(please order separately)

Mounting feet with isolation


washers and screws
ordered separately.
Replacement: 1 each
mounting foot and screws
Type. No.: BTL-5-FEET-STD

70

Transducer
Stroke Length
0051-0457
0508-0711
0762-0914
1016-1220
1270
1524
1778
2032
2286
2540
2794
3048
3302
3606

Number of feet
Factory recommends
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1-800-543-8390 www.balluff.com

Micropulse
R Style
Magnet
BTL Profile

Magnet
BTL Profile

Extended range, floating

Electro-magnet, floating

55

45

45

25

C
21

Magnets floating
Profile series

28

4.2

28
15

C
8 x 3.2 deep c-bore

50
68

Lateral offset:
C = 15mm

25
7.5

36 + 2

16.5

40
D

40 + 10

15

20

4.2

M5 x 8

Lateral offset:
C = 2mm
Vertical distance
of magnet:
D = 0.1...2mm

50
68

Vertical distance of magnet:


D= 5...15mm

BTL5-P-5500-2

BTL5-P-4500-1

Plastic
approx. 40g
any

40...+85 C

Plastic
approx. 90g
any
24 V DC
100 mA
40...+60 C

Magnet

Magnet

Straight connector
C04-AEC-00-VY-050M
Right-angle connector C04-BEC-00-VY-050M

Non-contact!
Vertical offset
0.1...4mm or
5...15mm

Please indicate cable length in ordering code:


03, 05, 10, 15 e.g. 050M = 5M

BTL

Mating connector for electromagnet

www.balluff.com 1-800-543-8390

71

Magnets captive
Profile series

Magnet
BTL Profile

Captive

Captive

Material

Housing
Slide surface

Weight
Magnet traverse speed
Operating temperature/storage
temperature

28

18

18

29

50

50

68

68

BTL5-M-2814-1S

BTL5-N-2814-1S

Anodized aluminum
Plastic
approx. 32g
any
40...+85 C

Anodized aluminum
Plastic
approx. 35g
any
40...+85 C

Mounting feet with isolation


washers and screws
ordered separately.
Replacement: 1 each
mounting foot and screws
Type. No.: BTL-5-FEET-STD

72

M5

M5
28

27

Ordering Code

21

Transducer
Stroke Length
0051-0457
0508-0711
0762-0914
1016-1220
1270
1524
1778
2032
2286
2540
2794
3048
3302
3606

15.5

40.5

37

21

23.5

40.5

23.5

Type

Magnet
BTL Profile

15.5

Description
for Series

35

Micropulse
R Style

Number of feet
Factory recommends
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1-800-543-8390 www.balluff.com

Micropulse
R Style
Description
for Series
Type

Magnets captive,
Profile series

Magnet
BTL Profile

Magnet
R-style only

Captive

Captive
70.5

18

23

18
18

14.5

14.5

40

40

31
24

41

24

28
M5 x 10

50
68

50
68

Ordering Code
Material

Housing
Slide surface

Weight
Magnet traverse speed
Operating temperature/
storage temperature

BTL5-F-2814-1S

BTL-R-2814-15

Plastic
Plastic
approx. 28g
any
40...+85 C

Plastic
Plastic
approx. 28g/m
any
40...+85 C

BTL

www.balluff.com 1-800-543-8390

73

Micropulse
R Style

Accessories

Product
Compatibility

Control Arm
BTL5-F-2814-1S
BTL5-R-2814-1S

Swivel Eye
BTL5-GS08-

Ball Joint
BTL5-GS08-

M5x0.8

36

8
13

41

13

42

22

M5x0.8

10

Ordering Code
Material
Weight

0117A044

0117A043

0117A042

M5x0.8

M5x0.8

BLT5-GS08- ___-A

BTL-5-SWIVEL-EYE

BTL-5-BALL-JOINT

Aluminum
150g/m

Aluminum/steel
14g

Aluminum/steel
11g

Specify control arm length in mm


e.g. BTL-5-GS08-0305-A

Product
Type

Mounting feet
Narrow

Mounting feet
Standard

7.2

7.2

15

12.7

12

Ordering Code
Material
Weight

74

42.7
57

0117A040

0117A041

9.1

50
68

BTL-5-FEET-NR

BTL-5-FEET-STD

Aluminum
6g

Black Anodized Aluminum


12g

1-800-543-8390 www.balluff.com

Micropulse
R Style

Wiring Diagrams

Analog Wiring Diagrams


Analog Voltage
24 V (A, B, G)

4
1
View of mating
connector, wiring side
6

PK

GN

GY

Analog output, rising


Analog common

BN

BU

+24 V

WH

Analog output, falling

GND
GND

0117a021

Analog Current
24 V (E, C)
1

YE

GY

Analog output
Analog common

BN

BU

+24 V

WH

GND
GND

0117a023

Digital Wiring Diagram


Digital, RS485 differential
24 V (P, M, I, K, L, R)
7
8

5
2

4
1
View of mating
connector, wiring side
6

0117a025

YE

PK

GY

GN

BN

BU

WH

Interrogate + Input
Interrogate - Input
Pulse + Output
Pulse - Output
+24 V

Note:

GND
GND

= twisted-pair

BTL

www.balluff.com 1-800-543-8390

75

Micropulse
R Style

Ordering Code
1

10 11 12 13 14 15 16 17 18 19 20 21 22
-

Balluff - Linear Transducer


Generation 5
Output Type
A = 0 to 10Vdc
B = -5 to +5Vdc
C = 0 to 20 mA
E = 4 to 20 mA
G = 10 to +10 Vdc

I = Differential start/stop with tri-state


K = Differential stop - leading edge active
L = Differential pulse-width modulated
M = Differential start/stop - leading edge active
P = Differential start/stop - trailing edge active

Supply Voltage
1 = 24 Vdc 20%
Analog Output Operation
(Leave Blank for Digital Versions)
Voltage type (Output type A, B & G)
1 = User selectable rising or falling
Current type (Output type C & E)
0 = Minimum output at connector end (rising towards opposite end)
7 = Maximum output at connector end (falling towards opposite end)
Normal Stroke Length
0

5 = 305mm active stroke

Housing Type
R = Low Profile Housing

Connection Type
S

K A

2 = 8-pin quick disconnect metal connector


0

5 = Cable out (5m standard; specify length in meters)

Standard Stroke Lengths (consult factory for additional lengths)


Electrical Stroke

inches
2
3
4
5
6
7
8
9
10
11
12
13

76

mm
0051
0077
0102
0127
0152
0178
0203
0230
0254
0280
0305
0330

inches
15
16
18
20
22
24
26
28
30
32
36
40

mm
0381
0407
0457
0508
0560
0610
0661
0711
0762
0813
0914
1016

inches
42
48
50
60
70
80
90
100
110
120
130
142

mm
1067
1220
1270
1524
1778
2032
2286
2540
2794
3048
3302
3606

inches mm
148
3759
156
3962

1-800-543-8390 www.balluff.com

Advanced Tube Profile

Micropulse AT
Transducer

Introduction

Micropulse AT
An all-around performer
Introducing the new noncontact linear positioning
transducer from Balluff.
The use of non-contact
position sensors is now an
affordable alternative to
wear-limited
potentiometers.

Product Range:
0-10 V analog

Start/stop pulse
interface
2-60 START/STOP

4-60 analog

Focus Features:
Rising and falling (P&M)
interface merge
together
Mechanically
compatible to
standard Micropulse
Dual analog output
versions for double
magnet applications
IP67

Floating magnet only


Connector versions
only no cable

Resolution 10
microns
Linearity 0.02%

The new Micropulse AT


magnetostrictive transducer
has been specifically
designed to meet the
demands of cost-conscious
machine builders. Free
from the old mechanical
technology, yet compatible
with standard products, the
round Micropulse AT design
sets new standards when it
comes to the price/
performance ratio!

Target Markets:
Printing

Flexible and cost-effective


mounting options and
state-of-the-art technology,
combined with a noncontact operating principle
make this sensor unique in
the industry. Both the
traditional 0-10 V analog
output version, as well as
the now widely-accepted,
highly noise-immune, start/
stop pulse interface are
available.

Plastic
Automotive

Applications:
Plastic injection molding
machines
Printing presses

General Specifications...pg. 80
Electrical Options...pg. 81
Wiring Diagrams...pg. 82
Accessories...pg. 83

AT

BTL

Potentiometer
connections,
block diagram

Micropulse
transducer
connections,
block diagram

The transition from a linear potentiometer to the Micropulse AT

www.balluff.com 1-800-543-8390

AT
79

Micropulse AT
Transducer

Dimensions
General Specifications

Series

Micropulse AT

Output signals

Analog Voltage & Digital Start/Stop Pulse

Transducer with floating magnet, S115 connection with BKS-S115/BKS-S116


connector for transducers with analog interface and digital pulse interface
Nominal stroke

Installation length

Ordering Code

BTL-6-___-M____-A1-S115 (see below)

Measurement type
Measurement range
Shock rating
Vibration rating
Environmental protection
Housing material
Operating temperature
Storage temperature
Humidity
Connection type
Compatible magnets

Linear displacement
51mm (2") to 1524mm (60")
50g/6 ms per IEC 60068 2-27
12g, 10 to 2000 Hz per IEC 60068-2-6
IP67 (with connector attached)
Anodized aluminum
+32 to +160 degrees F
-40 to +212F
<90% non-condensing
8-pin micro connector
See accessories

A1

BTL

Output Type/Supply Voltage


A110 = +24 Vdc Input
0 to 10 Vdc / 10 to 0 V dc output
P110 = +24 Vdc Input
RS422 Start/Stop pulse output
Normal Stroke Length
0

= 305mm active stroke

Standard Stroke Lengths


inches
mm
2*
0051
3*
0077
4
0102
5
0127
6
0152
7
0178
8
0203

inches
9
10
11
12
13
15
16

mm
0230
0254
0280
0305
0330
0381
0407

inches
18
20
22
24
26
28
30

mm
0457
0508
0560
0610
0661
0711
0762

inches
32
36
40
42
48
50
60

mm
0813
0914
1016
1067
1220
1270
1524

* Lengths only available with the digital (P110) interface

80

1-800-543-8390 www.balluff.com

Micropulse AT
Transducer
Analog
Voltage

Digital
Start/Stop & PWM

BTL-6-A110-M____-A1-S115

BTL-6-P110-M_______-A1-S115

010 V and 100 V


5mA max.
10 m
+/- 200m to 20" nominal stroke, typ +/0.02%, max. +/- 0.04% 20" to 60"
nominal stroke
10m
20m
[150V/ C +
(5ppm/C*P*V/NL)] * DT
24 Vdc 20%
70 mA

Digital START/STOP pulse


per spec
Controller dependent

Electrical interface
Electrical type
Part No. Code
Output
Output load
System resolution
Non-linearity

Repeatablity (resolution + hysteresis)


Repeat accuracy
Temperature coefficient *
Operating voltage
Operating current
EMC compatibility:
RF emission
Static electricity
Electromagnetic fields (RFI)
Fast transients (BURST)
Line-carried noise induced by highfrequency fields

EN 55011 Group 1, Class A


IEC 61000-4-2 Severity Level 3
IEC 61000-4-3 Severity Level 3
IEC 61000-4-4 Severity Level 4
IEC 61000-4-6 Severity Level 3

*Temperature coefficient
variables:
V = output range in V
I = output range in [mA]
DT = temperature change
P = magnet position

Output Options

Ordering Code

0...+10V

A (pin-5)

+10...0V

A (pin3)

Start/Stop

Leading and Trailing


edge active

P110
Trailing edge
Leading edge

0118A003

Electrical Options

+/- 200 m to 20" nominal stroke, typ +/0.02%, max. +/- 0.04% 20" to 60"

nominal stroke
10m
20m
[0.6A/C +
(10 ppm/C*P*V/NL)] * DT
24 Vdc 20 %
60mA (at 1K Hz sampling rate)
EN 55011 Group 1, Class A
IEC 61000-4-2 Severity Level 3
IEC 61000-4-3 Severity Level 3
IEC 61000-4-4 Severity Level 4
IEC 61000-4-6 Severity Level 3
P110 Interface
Compatible with Balluff BTA processors
and various OEM controls, e.g., AllenBradley, Siemens, Mitsubishi, Parker,
Bosch, Esitron, etc. The P110 START/
STOP interface offers reliable signal
transmission over cable lengths up to
1,600 feet. RS422-compatible differential
line drivers/receivers are used to ensure
that noise signals are effectively
supressed.
P110 Replaces P1 & M1
Based on differing philosophies, two
controller-specific interfaces have been
established for the digital pulse versions.
The difference lies in how the edges are
processed. In the "P" interface, the falling
edges are processed and in the "M"
interface, the rising edges are processed.
To reduce the amount of part numbers,
the "P110 interface" has been
developed which combines both
functions. The reference point for the
propagation time measurement is the
"Start" pulse.

AT

BTL

Active Stroke

www.balluff.com 1-800-543-8390

81

Micropulse AT
Transducer

Wiring

Product
Type

Connector, Straight
Micropulse AT Connector

Connector, Right-angle
Micropulse AT Connector

BKS S115-PU-_ _

BKS S116-PU-_ _

PUR
CuZn
0.8m Au
IP 67
CuZn
2.5m Ni
Viton
Molded-on PUR
8 0.25mm2 (24 AWG)
PVC
14 0.15mm
6.6 0.2mm
dynamic 4 D, static 3 D

PUR
CuZn
0.8m Au
IP 67
CuZn
2.5m Ni
Viton
Molded-on PUR
8 0.25mm2 (24 AWG)
PVC
14 0.15mm
6.6 0.2mm
dynamic 4 D, static 3 D

Ordering Code
Housing material
Contacts
Contact finish
Enclosure rating per IEC 60529
Knurled coupling ring
Finish
O-ring
Cable
No. of wires conductor cross section
Type
Conductor configuration
Outer diameter
Min. bending radius
Ordering code for available lengths:
02 = Length 2m
10 = Length 10m
05 = Length 5m
15 = Length 15m
Analog (A110) Wiring Diagram
Analog Voltage
24 V (A110)

5
4
3

Digital (P110) Wiring Diagram

6
7

1
8
View of mating
connector, wiring side

Digital
24 V (P110)

PK

Analog output, falling

GN

Analog output, rising

GY

Analog common (rising output)

BN

+24 V

BU

YE

GND
Analog common (falling output)

0118a005

Pins 4 and 8 must remain unconnected

4
3

6
7

1
8
View of mating
connector, wiring side

YE

PK

GY

GN

BN

BU

Interrogate + Input
Interrogate - Input
Pulse + Output
Pulse - Output
+24 V
GND

0118a006

Pins 4 and 8 must remain unconnected

Block diagram
of P interface

82

1-800-543-8390 www.balluff.com

Micropulse AT
Transducer
Product
Type

Mounting Clamp
Standard

Mounting Clamp
Cuff

Accessories

Magnet
Floating

B
60
57

BTL-6-A-MF01-A-50
BTL-6-A-MF01-A-43
Aluminum
16g

Material
Weight

30

5.5

9
42

18

Pl0052c

A
50
42.7

19

38

Part
-50
-43

18
3
Pl0050c

35

7.5
15

Ordering Code

10

5.5

5.5

30

55

BES-30-BS-1

BTL-6-A-3800-2

Plastic
21g

Plastic
40g
Installation Note:

BTL6-P11-M-0050AT-S11x

When extreme shock and vibration are


present, spacing mounting clamps every
250mm is recommended.

Custom mounting
options:

The BTL6-A-3800-2 magnet can be


operated at a distance of 4...8mm
from the top surface of the profile
housing. Together with the BTL6-AMF01-A50 mounting clamps, the
mechanical installation is compatible
with the BTL5-...-P-S 32 using
BTL5-P-3800-2 or BTL5-P-5500-2
magnets. This means for example
that long stroke lengths or
transducers with a bus interface can
be interchanged without making any
mechanical modifications.

AT

BTL

www.balluff.com 1-800-543-8390

83

Micropulse
Linear Position
Transducers

Contents
Connectors &
Accessories

Connector overview
pg. 86
Connectors
for standard interfaces
A, C, E, G, P, M, I
pg. 87
Connectors
and accessories
for CANopen
pgs. 88-89
Connectors
and accessories
for PROFIBUS-DP
pgs. 90-91

BKS

www.balluff.com 1-800-543-8390

85

Micropulse
Linear Position
Transducers

Connector overview

Connectors
for standard interfaces
A, C, E, G, P, M, I, S
Connectors
for CANopen

Connectors
for PROFIBUS-DP

86

1-800-543-8390 www.balluff.com

Micropulse
Linear Position
Transducers
Connectors
for series

BKS-S 32M
BTL5-...-S 32

BKS-S 33M
BTL5-...-S 32

BKS-S 140
Quadrature

Type

Straight, female

Right angle, female

Straight, female

Connectors
for standard interfaces
A, C, E, G, P, M, I, S

24

0117A052

55

Ordering Code
Crimp contacts
Solder connection
Housing material
Contact
Contact finish
Cable strain relief
Cable diameter min.
Cable
No. of wires
conductor cross section
Enclosure rating per
IEC 60529

BKS-S 32M-__

BKS-S 33M-__

BKS-S 140__

max. 0.75mm2/
AWG 18
Nickel plated brass
Brass
0.8m gold plated
PG 9
6...8mm
PVC (PUR optional)
7 0.25mm/AWG 24

max. 0.75mm2/
AWG 18
ZnAlCu1 nickel plated
Brass
0.8m gold plated
PG 9
6...8mm
PVC (PUR optional)
7 0.25mm/AWG 24

max. 0.75mm2/
AWG 18
Nickel plated brass
Brass
0.8m gold plated
PG 9
6...8mm
PVC
7 0.25mm

IP 67 (when attached)

IP 67 (when attached)

IP 65 (when attached)

Please indicate cable length in ordering code.


Code 00 for self-assembly
(please use shielded cable).
Code 05, 10, 15, 20, 25, 30 m
for finished cable assembly.

BKS

Pin assignments
7

2
6

View of female
solder side

Pin
1
2
3
4
5
6
7

Color
Yellow
Grey
Pink
Green
Blue
Brown
White

www.balluff.com 1-800-543-8390

87

Micropulse
Linear Position
Transducers
Connectors/accessories
for series

BKS-S 92-00
BTL5-H___-S 92

BKS-S 94-00
CANopen

BKS-S 93-00
BTL5-H___-S 92

BKS-S 95-00
CANopen

Type

Straight, female

Straight, male

Right angle, female

Right angle, male

Ordering Code

BKS-S 92-00

BKS-S 94-00

BKS-S 93-00

BKS-S 95-00

Screw terminal

max. 0.75mm2/
AWG 18
Nickel plated brass
Brass
0.8m gold plated
PG 9
6...8mm

max. 0.75mm2/
AWG 18
Nickel plated brass
Brass
0.8m gold plated
PG 9
6...8mm

max. 0.75mm2

max. 0.75mm2

Nickel plated brass


Brass
0.8m gold plated
PG 9
6...8mm

Nickel plated brass


Brass
0.8m gold plated
PG 9
6...8mm

IP 67
(when attached)

IP 67
(when attached)

IP 67
(when attached)

IP 67
(when attached)

Housing material
Contacts
Contact finish
Cable strain relief
Cable diameter
No. of wires conductor
cross section
Enclosure rating per IEC
60529
Knurled coupling ring
Finish
O-ring
Resistor

Pin assignments

View of female
coupling side

88

Connectors and accessories


for CANopen

BKS-S 92-00/-S 93-00/


-S 94-00/-S95-00

BKS-S 92-R01/-S 94-R01

Pin
1
2
3
4
5

Pin
1
2
3
4
5

Signal
CAN_GND
+24 V
GND (0 V)
CAN_HIGH
CAN_LOW

Signal
121 Ohms

1-800-543-8390 www.balluff.com

Micropulse
Linear Position
Transducers
BKS-S 92-TA1
BTL5-H___-S 92
T-splitter, 2 x F, 1 x M

BKS-S 92-R01
CANopen

BKS-S 94-R01
CANopen

Termination resistor, female Termination resistor, male

Connectors and accessories for


CANopen
BKS-S 92-16/GS92-__
BTL5-H___-S 92
Male/female extension

BKS-S 92-TA1

BKS-S 92-R01

BKS-S 94-R01

BKS-S 92-16/GS92-_ _

PA
Brass
Ni

TPU
Brass
0.8m gold plated

TPU
Brass
0.8m gold plated

PUR
Brass
0.8m gold plated

5 0.34mm2/AWG 22
IP 67

IP 68

IP 68

IP 67

Brass
2.5m Ni
HBR

Brass
2.5m Ni
Viton
121 Ohms

Brass
2.5m Ni
Viton
121 Ohms

Brass
2.5m Ni
Viton
Please indicate cable
length in ordering code.
02 = Length 2m
05 = Length 5m
10 = Length 10m

BKS

www.balluff.com 1-800-543-8390

89

Micropulse
Linear Position
Transducers

Connectors and accessories


for PROFIBUS-DP

Connectors/accessories
for series
Type

Ordering Code
Screw connection
Housing material
Contacts
Contact finish
Cable strain relief
Cable diameter
No. of wires conductor cross section
Enclosure rating per IEC 60529
Knurled coupling ring
O-ring
Resistor

Pin assignments
Control and data signals

Supply voltage and shield

90

BKS-S 103-00
BTL5-T1...-S103

BKS-S 105-00
BTL5-T1...-S103

BKS-S103/GS103-CPBTL5-T1...-S103

5-pin, female

5-pin, male

Male/female extension

BKS-S 103-00

BKS-S 105-00

BKS-S103/GS103-CP-

max. 0.75mm2/AWG 18
Nickel plated brass
Brass

max. 0.75mm2/AWG 18
Nickel plated brass
Brass

PUR
Brass

PG 9
6...8mm

PG 9
6...8mm

IP 67 (when attached)

IP 67 (when attached)

Data GND
RxD/TxD-N (A)
RxD/TxD-P (B)
VP +5 V
+24 V
0 V (GND)
Ground PROFIBUS-DP
Shield Supply

S 103 5-pin
3
2
4
1

S 103 3-pin

2 0.64mm2/AWG 18
IP 67 (when attached)
Nickel plated brass
Viton

Please indicate cable length


in ordering code.
003= Length 0.3m
02 = Length 2m
05 = Length 5m
10 = Length 10m

1
3
5
4

1-800-543-8390 www.balluff.com

Micropulse
Linear Position
Transducers
BKS-S 105-R01
BTL5-T1...-S103

Connectors and accessories


for PROFIBUS-DP

Termination resistor, male

BKS-S 48-15-CPBTL5-T1...-S103
Supply voltage
3-pin, female

BKS-S 86-00
BTL5-T1...-S 86
Round connector
12-pin, male

BKS-S 86-TA1
BTL5-T1...-S 86
T-splitter
12-pin, Male, female, female

BKS-S 105-R01

BKS-S 48-15-CP-

BKS-S 86-00

BKS-S 86-TA1

PUR
Brass

PUR
Brass

Nickel plated brass


Brass
Gold plated

Nickel plated brass


Brass

IP 67 (when attached)

IP 67 (when attached)
Brass

IP 67 (when attached)
Nickel plated brass
Viton

2 0.25mm/AWG 24
IP 67 (when attached)

Please indicate cable


length in ordering code.
02 = Length 2 m
05 = Length 5 m
10 = Length 10m
Pin assignments
Control and data signals

Supply voltage and shield

www.balluff.com 1-800-543-8390

Data GND
RxD/TxD-N (A)
RxD/TxD-P (B)
VP +5 V
+24 V
0 V (GND)

S 86
1
2
4
6
7
8

BKS

91

Micropulse
Linear Position
Transducers

Contents
Processors

A series of processor cards


with various functions and
interface variations has been
developed for use with the
Series BTL5-P... transducers
with digital pulse interface.
These cards are required if your
controller does not have a
Balluff P-interface but you wish
to utilize the advantages it
brings (noise-immunity, cable
lengths up to 500 m). The BTA
processors convert the pulses
sent by the BTL5-P transducer
into standard digital or analog
signal formats.

BTM Module
Pg. 94
BUS interface with
position module
pg. 95
Analog and digital
processor cards for
transducers having
the P-interface,
analog module
pgs. 96-97
Digital display,
Cam controller
pgs. 98-99

BTA

www.balluff.com 1-800-543-8390

93

Micropulse
Linear Position
Transducers

BTM Analog Interface Module


BTM-A1
Analog Output Processor

Type

Description:
Used in conjunction with the
Balluff BTL-5-P1...START/
STOP Linear transducer, the
Balluff BTM-A is used to
provide up to 4 channels of
analog position and/or
velocity feedback. In
multi-magnet mode, the
BTM-A can be used to
provide independent
position information on up
to 4 magnets on the Balluff
transducer.
Features:
User-programmable
outputs:
-10 to +10, -5 to + 5,
0 to 5, 0 to 10 Vdc,
4-20mA
Standard DIN-rail
mounting
Fast 0.5 ms update rate

Noise-immune RS-422

interface allows for


cable lengths of up to
1,600 feet between
transducer and BTM-A
Outputs short-circuit
and reverse-polarity
protected

Ordering Code
Input
Outputs
Operating voltage
Current draw
Operating temperature
Number of outputs
Position output
Velocity output
Velocity range
Output resolution
Update rate

See opposite page


Balluff BTL-5-P1-... START/STOP linear transducer
Analog position and/or analog velocity
+24 Vdc 20%
125 mA max (excluding transducer)
0 to 70 C
1 to 4 (see ordering code)
0 to 10 Vdc, -10 to +10 Vdc , -5 to +5 Vdc, user programmable
-10 to +10 Vdc
2 to 400 inches/sec.
16-bit
0.5ms

10 11 12 13 14 15 16 17
2

Balluff-Transducer-Module
Analog Interface
A = Voltage output, E = current output
Supply Voltage
1= +24 Vdc (+/-20%)
Version
001 = 1 analog output (position or velocity)
002 = 2 analog outputs (1 position, 1 velocity or 2 position or 2 velocity)
003 = 3 analog outputs (position only)
004 = 4 analog outputs (position only)
Velocity Option (leave blank if velocity feedback is not required
Indicates pre-programmed velocity scaling
If M in position 13 specify velocity in millimeters/second
If U in position 13, specify velocity in inches and tenths of inches/second
e.g.
VU0300 = velocity scaling of 30.0/second
VM0762 = velocity scaling of 762mm/second

94

1-800-543-8390 www.balluff.com

Micropulse
Linear Position
Transducers

BUS interface
with position module

PMT-Systron-000
InterBus-S DIN EN 50254, PROFIBUS-DP
DIN EN 50170, MODBUS, CANopen, DeviceNet
serial interface RS232 or RS485

Positioning module
through PM module to
through RS module to

The PMT positioning module is


used to link BTL5-I1 transducers
to Schiele bus and interface
modules:

Ordering Code

PMT-Systron-00

Features

InterBus-S DIN EN 50254


PROFIBUS-DP DIN EN 50170
MODBUS
CANopen
DeviceNet
to serial interfaces
RS232 or RS485

Resolution
Position update time
Ultrasonic gradient correction

Easy connection to various bus systems, high noise


immunity, flexibly expandable with I/O and analog
modules, easy assembly, four transducers can be
connected to one module, can be expanded later.
10m
max. 0.5ms (2 kHz)
settable on the bus
(BTL ultrasonic velocity compensation)
automatic, corresponding to physical layout
0.5ms/module
one BTL active at a time, BTL activated over the bus
Inputs: START/STOP differential
Interface: bus-compatible
Transmission distance: max. 500m
between BTL5-I1 and PMT
Screw terminals 2 2.5mm
No. of connected BTL5-I1: max. four,
optocoupler isolated
24 V DC 10 %
internal 250 mA (5 V) over Schiele bus
external 50 mA (24 V) BTL5-I1
0...55 C

Between 1 and 4 BTL5-I1


transducers can be connected to
the PMT positioning module.
Ribbon cable is used to make the
actual PM bus connection or to
the RS interface module.
For more information on BUS
Interface modules which are
compatible with the
PMT-SYSTRON-00, contact:
Entrelec, Inc.
Irving, TX
(972) 550-9025

Addressing
Data exchange time
Position data select
Position data from BTL5-I1

Connections

Operating voltage
Current draw
Operating temperature

PMT positioning
module

RS232
RS485

BTA

InterBus-S
PROFIBUS-DP
MODBUS
CANopen
DeviceNet

BUS Interface modules


available directly from
Entrelec, Inc.
Irving, TX
(972) 550-9025

www.balluff.com 1-800-543-8390

95

Micropulse
Linear Position
Transducers

Analog processors
Series
Position
Output
Velocity
signal
Input interface (transducer)

BTA-C
analog
analog
P

BTA-E
analog
analog
P

BTA-A1_-_ _ _ _

BTA-C1_-_ _ _ _

BTA-E1_-_ _ _ _

Features

Resolution
0.1mV/0.2A,
LED function display,
Null adjust 15 %,
Span adjust 15 %,
Velocity output,
Error output (relay)

Resolution
0. mV/0.2A,
LED function display,
Null adjust 15 %,
Span adjust 15 %,
Velocity output,
Error output (relay)

Resolution
0.1mV/0.2A,
LED function display,
Null adjust 15 %,
Span adjust 15 %,
Velocity output,
Error output (relay)

Connector

Edge connector
32-pin, DIN 41 612 F
24 V DC 20 %
130mA at 24 V DC
0...60 C
1 kHz
analog
voltage

Edge connector
32-pin, DIN 41 612 F
24 V DC 20 %
130mA at 24 V DC
0...60 C
1 kHz
analog
voltage, current

Edge connector
32-pin, DIN 41 612 F
24 V DC 20 %
130mA at 24 V DC
0...60 C
1 kHz
analog
voltage, current

Position

analog
0...10 V and 10...0 V

analog
0...10 V and 10...0 V
0...20mA

analog
0...10 V and 10...0 V
4...20mA

Velocity

analog
10 V

analog
10 V

analog
10 V

Ordering Code

Operating voltage
Current draw
Operating temperature
Update time
Interface

Output
signals

Features:
The processors are
configured in a
Eurocard format for
use in 19" racks
and card holders.
The position values
are updated at a
frequency of max.
2 kHz, so that
the actual position
can be captured
even at high
traverse speeds
with negligible lag
error.
High resolution
(down to 0.01mm)
provided by
microcontrollercontrolled
digitizing.
Parallel data format
selectable binary,
BCD or Gray.
Noise-immune data
transmission
between processor
and transducer
provided by
RS485/422
differential drivers,
with cable lengths
up to 500m.
ERROR output for
immediate
notification of cable
break, defective
or missing magnet.

BTA-A
analog
analog
P

Please enter code for output signal and


nominal stroke in ordering code.
Micropulse analog processor
Ordering example:

BTA-A1_-_ _ _ _-V _ _ _
Output signal

0
7
1

96

rising, use only for

Nominal stroke
transducer
in [mm]
Velocity (optional)
specify max velocity in inches/second

current output
falling, use only for
current output
rising/falling, use only
for voltage output

1-800-543-8390 www.balluff.com

Micropulse
Linear Position
Transducers
BTA-G
analog
analog
P

BTA-D11
digital

BTA-H11-_ _ _
digital

BTA-S11
digital

Digital and analog processors,


analog module
BKS-S39

Typical card height


59

147

0117A054

140

BTA-G1_-_ _ _ _

BTA-D11-_ _ _

Resolution
0.1 mV/0.2A,
LED function display,
Null adjust 15 %,
Span adjust 15 %,
Velocity output,
Error output (relay)

Resolution 0.025mm,
DATA HOLD,
LED function display,
ENABLE,
bus-compatible

Edge connector
32-pin, DIN 41 612 F
24 V DC 20 %
130 mA at 24 V DC
0...60 C
1 kHz
analog
voltage

Edge connector
48-pin, DIN 41 612 F
24 V DC 20 %
max. 200 mA
0...60 C
1 kHz
digital
20-bit parallel
binary

analog
10...+10 V and 10...
10 V

digital
TTL 5 V DC
PNP source driver,
10...30 V DC

BTA-H11-_ _ _

BTA-S11-_ _ _

Resolution 0.01mm,
BCD, binary, Gray code,
null point adjustment,
direction signal, DATAREADY,
Min-Max programming,
ENABLE, DATA HOLD,
bus-compatible,
serial interface
(for BDD display)
Edge connector
48-pin, DIN 41 612 F
24 V DC 20 %
max. 500 mA
0...60 C
2 kHz
digital
22-bit parallel BCD,
binary, Gray code,
24-bit synchronous
serial (SSD)
digital
TTL 5 V DC
PNP source driver,
10...30 V DC

Resolution 0.01mm,
accepts 2 transducers,
16 switching outputs,
Teach-In programming,
STAND ALONE/complete position controller,
serial interface (for BDD
display), can be programmed with PC and
BTASEDIT software
Edge connector
48-pin, DIN 41 612 F
24 V DC 20 %
max. 350 mA
0...60 C
0.75 kHz
digital
16 outputs with 1 BTL
connected, 8 each for
2 BTL transducers

BKS-S39-F48-SMCH
Panel mounted card
holder for BTA
processors. Provides
screw terminals for all
connection points

Edge connector
48-pin, DIN 41 612 F

digital
TTL 5 V DC
PNP source driver,
10...30 V DC

analog
10 V
Please enter code for output driver in
ordering code.
Micropulse digital processor
Ordering example:

BTA

BTA-D11-_ _ _
Output driver
for BTA-D, BTA-S
200
300

Source-Driver (PNP with SCP 10...30 V)


TTL outputs tri-state

for BTA-H
240
340

www.balluff.com 1-800-543-8390

Source driver (PNP with SCP, 10...30 V)


and 24-bit synchronous serial data transmission (SSI)
TTL outputs tri-state
and 24-bit synchronous serial data transmission (SSI)

97

Micropulse
Linear Position
Transducers

Digital Display
Cam Controller

Name
Series

BDD-100
Digital display
for BTL5 with
P-interface

BDD-07-9
Digital display
for Processors
BTA-H, -S, -V, -M

96

48

0117A055

Enter
Zero

Ordering Code
Features

98

housing depth 110 mm

BDD-100
6-digit, 0.57" high, seven-segment LED
display
0.002" resolution
Fixed 5 ms update rate
Programmable decimal point, Units, and
Gradient
Remote Zero
RS-232 serial interface for programming
and data transfer
Removable Phoenix-type connectors
Front panel lock-out
24 V DC input power

BDD-07-9

6-digit
LED display 12 mm high red 7-segment
0.0004 resolution
selectable mm/inch
isolated DIN housing for panel mount
(mounting hardware included)
24 V DC input power
Use in conjunction with Balluff processor
cards BTA-H, BTA-S, BTA-V, and BTA-M
Can NOT be used as stand-alone display

1-800-543-8390 www.balluff.com

Micropulse
Linear Position
Transducers
Name
Series

BDD-AM 10-1-P
Digital display
for BTL5 with
P-interface

BDD-AM 10-1-SSD
Digital display
for BTL5 with
SSI interface

BDD-AM 10-1-P

Features

BDD-CC 08-1-P
Cam controller
for BTL5 with
P-interface

BDD-CC 08-1-SSD
Cam controller
for BTL5 with SSI
interface

housing depth 110 mm

housing depth 110 mm

Ordering code

Digital Display
Cam Controller

BDD-AM 10-1-SSD

7 1/2-digit display with sign


LED display 14 mm high red 7-segment
0.001 resolution (BDD-AM 10-1-P)
0.0002 resolution (BDD-AM10-1-SSD)
scalable units
variable decimal point setting
adjustable null point
operating voltage 10...32 V
2 programmable relay outputs, defined as
limit switch/comparator
dwell
2-position (on if below,
off if above set value)
1 configurable input
external null set
latch display value
isolated DIN housing for panel mount
(mounting hardware included)
24 V DC input power

BDD-CC 08-1-P

BDD-CC 08 1-SSD

8 programmable outputs
8 directional switchpoints possible
LED display, 14 mm high red 7-segment,
6-position
0.002 reolution (BDD-CC08-1-P)
0.0002 resolution (BDD-AM10-1-SSD)
LED switchpoint status on
front panel
300 switchpoints can be distributed
over up to 15 programs
adjustable nullpoint shift
static and dynamic setpoints with deadtime
compensation
multiple BDD-CC 08 can be wired in
parallel
built-in transducer supply voltage
300 mA, 24 V
isolated DIN housing for panel mount
(mounting hardware included)
18...32V DC input power

BTA

www.balluff.com 1-800-543-8390

99

Terminology
Resolution
The smallest increment of
position change that can be
detected by the transducer.
The resolution of Micropulse
transducers depends on the
output type chosen.
Digitally-Derived Analog
(Z housing, rod-style only)
Output resolution is
expressed as 16-bits. The
digital position information is
converted into an analog
signal internally through a
digital-to-analog converter.
True Analog (all other
housing styles)
The analog output is derived
without using a digital-toanalog converter. Resolution
for this type of system is
virtually infinite. Attainable
resolution is determined
primarily by electrical noise
inherent to the application,
and input resolution of the
control system.

DigitalPulse Output
(all housings)
For digital pulse-output
systems (i.e. Start/Stop or
PWM) resolution is determined by the clock
frequency of the customer
interface which measures
the time interval between
the Start pulse and the Stop
pulse (or the rising and
falling edges of the PWM
signal). Resolution can be
determined as follows:

Resolution (in inches) =


1 (Gradient x Clock
Frequency)
The gradient value is printed
on the label of each
transducer and is expressed
in microseconds per inch
(sec/inch).
The Clock Frequency is the
frequency of the counter in
the customer supplied
interface and is usually
expressed in megahertz
(MHz).

Non-Linearity
The degree to which the
output value from the
Micropulse transducer
system is not perfectly
proportional to travel
distance. Standard
transducers show a
non-linearity of max.
0.02% full scale. Example:
a 24-inch stroke BTL5 with
analog output may output a
position value which is
0.0048" greater or less than
the true, absolute position.
This value is repeatable,
however, to within 0.0002"
(see resolution and
repeatability). For higher
accuracy requirements,
Micropulse transducers with
Synchronous Serial Interface
(SSI) can be used.
Hysteresis
The difference in indicated
position when the same
point is reached from two
different directions.
Repeatability refers to travel
from one direction only,
hysteresis from two
directions.

Example - assuming a
gradient value of 9.000 s/
inch and a clock frequency
of 56 MHz

Ex

BTL

Resolution (in inches)


= 1 (9 x 56)
= 1 504
= 0.00198

Digital Serial Systems


(SSI, Canbus, etc.)
Resolution is a defined
value, stated in inches.
Temperature
Coefficient
Expressed as ppm/C or F,
TC is the degree to which
the output signal (and
therefore the indicated
position) is affected by
ambient temperature
changes.

www.balluff.com 1-800-543-8390

Repeatability
The degree to which the
indicated position point B as
represented by the output
value is reproduced when
moving in one direction from
point A and back to point B.
In the case of a BTL5
system, position repeat
accuracy is always the same
as the stated resolution +
hysteresis.

Terms &
Conditions
Dead Zone
The end of the Micropulse
transducer rod, from end
of stroke to the end of the
rod. This is usually the last
2.3 inches of the rod. If the
magnet enters the dead
zone the output will be
unpredictable.
Null Space
The distance from the head
of the transducer to the
start of the electrical
stroke.
Null Position
The position of the magnet
on the transducer rod
which reads a zero or
minimum output.
Stroke
The active electrical portion
or the sensing portion of
the Micropulse transducer.
Analog
The output of the transducer is an analog voltage
(0 to 10 Vdc,
-10 to +10 Vdc, or -5 to 5
Vdc) or an analog current
(0 to 20 mA, 4-20 mA) and
is proportional to the
position of the magnet.
Digital Pulse Output
The output of the
transducer is a digital Start/
Stop pulse or a Pulse
Width Modulated (PWM)
signal. Magnet position is
directly proportional to the
time interval between the
Start pulse and the Stop
pulse (or the rising and
falling edges of the PWM
signal). An external
counter is required to
measure this time interval.
A wide variety of processor
cards, PLC plug-in cards,
and stand-alone controllers
designed around this
interface are available.
Digital Serial Output
The output of the
transducer is in the form of
a serial data word or string
in SSI (binary or Gray code)
or CANbus format.

101

Terminology

102

Output Signals

Analog voltage output

Analog current output

Pulse interface

The output voltage is


directly proportional to the
position of the magnet
along the waveguide.
The most important
parameter for analog
outputs is the refresh rate
and the ripple of the output
signal. Many transducers on
the market attain the
specified values for output
ripple only by means of
low-pass filtering. This
always carries with it an
undesirable time delay of
the output signal.
Micropulse transducers
attain the specified signal
quality without extensive
low-pass filters, instead
using improved circuit
design. This means fast
update times with low levels
of ripple and noise on the
output signal. Micropulse
transducers with voltage
output have 2 outputs, one
increasing and one
decreasing.
Available versions include:
0...10 V (10...0 V)
10...10 V (10...10 V) and
-5...5V (5V...-5V)

The output signal is directly


proportional to the magnet
position along the
waveguide. Analog current
interfaces of 0...20 mA and
4...20 mA are standard in
numerous applications and
in many industries. Current
interfaces are significantly
less sensitive to induced
noise than are analog
voltage interfaces. A 500
Ohm resistor can be used
to easily convert the 0..20
mA signal into a voltage of
0...10 V. The 4...20 mA
signal provides a simple
form of cable break
monitoring, since even at
the nullpoint of the stroke a
current of 4 mA must flow.
Micropulse transducers with
current output are available
with increasing or
decreasing signals.

The time between an


interrogation and the reply
signal is directly proportional
to the position of the
magnet along the
waveguide. These pulses
are transmitted using
RS485/422 differential line
drivers, guaranteeing noisefree signal transmission over
distances of up to 500m
(1640ft.). The great
advantage of these
interfaces is the noiseimmune signal transmission
with a simple and economical interface. Interfaces with
tristate outputs allow
multiplexing of several
Micropulse transducers.
Appropriate control cards
are available.

SSI synchronous serial


interface
The position of the magnet
along the waveguide is sent
to the control serially in the
form of a data word.
Micropulse transducers with
SSI interface can be
connected directly to
controls or closed-loop
control cards with SSI
interfaces designed for
absolute encoders. The
data transmission from the
sensor to the control is
synchronized by means of a
clock pulse from the
control. Depending on the
required resolution,
transducers with 24 or 25bit data words are available.
The maximum non-linearity
of the SSI Micropulse
transducer of
30m over the entire
stroke, the update
frequency of 2kHz and a
resolution of 5m make the
SSI Micropulse transducers
an ideal feedback sensor,
even in the most
demanding applications.

1-800-543-8390 www.balluff.com

Terminology

Output Signals

Quadrature
A+B

A
B

CANopen
The position of the magnet
along the waveguide is sent
over the CAN-Bus to the
control in so-called Process
Data Objects, PDOs.
Micropulse transducers
work with standard
CANopen protocols per CiA
DS 301 and with the
standard device profile per
DS 406. CANopen offers
greater flexibility because of
the large number of
configuration options for the
transducer. For example,
the resolution is programmable for 5, 10, 20 or 100
m, depending on your
application. Or you can
select whether only position
or also velocity information
shall be sent to your
control; cyclically, or ondemand. And there's more:
Up to 4 so-called software
cams can be defined in the
active stroke range. Each
time
the status of one of
BTL
these cams changes, highpriority Emergency
messages are sent to the
control (check factory for
availability).

Ex

- Consult factory for


technical data

InterBus-S, PROFIBUSDP, DeviceNet, MODBUS


Up to 4 Micropulse
transducers with pulse
interface can be quickly and
easily adapted to a wide
range of bus systems;
no problem when you use a
PMT module from Balluff
and a process module from
Schiele Entrelec. It often
happens that applications
have to be specially
adapted to existing or
specified bus systems. The
combination of Micropulse
transducer with pulse
interface (BTL5-I1...), PMT
and PM module simplifies
this process with standard
components. Difficult or
decentral island solutions
can be implemented costeffectively using additional
process modules from
Schiele Entrelec.

Quadrature
The quadrature output
interfaces directly to
standard encoder inputs
(90 out of phase, A & B).
This configuration gives
you more interface options
for connecting to motion
based systems. Operating
modes can be either freerunning or synchronous
(switch selectable)
depending on the control
system's requirements.

averaging between
transducers
closed-loop tasks (PID)
timing sequences
remote monitoring
PLC functions

- Consult factory for


technical data

www.balluff.com 1-800-543-8390

103

Вам также может понравиться