Вы находитесь на странице: 1из 25

All about DT [DRIVE-TEST] problems

2G Cross problems [Part 2]






Prepared by:
Eng. Abdelrahman Ashraf Mostafa
EPM- Ericsson
E-mail: abdelrahman_ashraf@hotmail.com
Phone: +2-0109-6739100






All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

2

NOTE: Each sector antenna in site is connected to 6 ports [sometimes reaches 12],2 ports for 2G GSM 900 MHZ
band, 2 for 2G DCS 1800 MHZ band and the last 2 for 3G UMTS 2100 MHZ band, where every 2 ports are
completely separated from any other ports in connection to the sector antenna.
So, cross [sector or feeder] can occur in 1 band while the other 2 bands are correctly connected.

You can notice that each of the 3 bands is connected to the antenna with 2 feeders as we've said before:
- 1
st
feeder is TX/RX feeder which is connected to carry and deliver the transmitted power for sector ARFCNs
[BCCH & TCHs] from the sector BTS cabinet to the sector tower antenna, also it is used to deliver the signal
received by sector antenna in the up-link from the MS to the BTS cabinet, where any wrong connection for this
specific feeder will result in a cross case for sure.
-2
nd
feeder is RX feeder which is connected for the up-link RX diversity.
So, we name the case cross sector if and only if both the 2 TX/RX and RX feeders are connected to the wrong
sector antenna, where the 2 feeders of BTS 1
st
cabinet are connected to sector 2 antenna and vice versa.
BUT, if only 1 of the 2 feeders whether the TX/RX feeder or the RX feeder is connected to the wrong sector
antenna, it is named a cross feeders case as we'll demonstrate.


All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

3
1-2G Cross Sector;
When 2 sectors S1 and S2 in same site each is serving in the other sector main beam area with a good BCCH Rx-level
while the other non-serving sector BCCH appears as a neighbor in [GSM Serving + Neighbors] window with bad
Rx-level or not appears at all as its level is too low to be even detected by MS.
NOTE: Levels of the supposed serving sector [which is not serving due to cross case] must be very bad in its
supposed main beam serving region and vice versa to confirm this is a cross sector case not cross feeders.
Imagine a site consists of 2 sector antennas, each include only 4 ports [GSM and DCS] no 3G for now, so the normal
correct configuration for these 4 feeders from cabinets are to be connected to the sector antennas as shown in the
following snap.












As we've said before a cross case can occur in 1 band only GSM or DCS and don't have to affect the other band.
There are 3 types of Cross sector:
GSM cross sector.
DCS cross sector.
Total (GSM & DCS) cross sector.






All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

4
1-GSM cross sector:
When the 2 feeders from GSM BTS 1st cabinet are connected to sector 2 antenna and the 2 feeders from GSM BTS
2nd cabinet are connected to sector 1 antenna.













NOTE: The 2 feeders should both be reversed with each other's to call this a cross sector case as if only 1 of the 2
feeders is wrong connected it will be a cross feeder case not cross sector as we will demonstrate.
NOTE: When performing a cross test for any site, keep your eye on these 2 important windows [GSM Serving +
Neighbors] window as it will indicates all the serving and neighboring cells BCCH's Rx-levels and [GSM Hopping
Channels] window as it will indicates the serving cell TCH's Rx-levels received by your MS in down-link.










All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

5
Example:
In front of sector 1 main beam
You find sector 2 BCCH: 8, TCH: 37 is serving with very good Rx-level in front of sector 1 main beam supposed
coverage region while sector 1 BCCH: 55 Rx-level is bad.
Clearly cross case is detected between sectors 1 and 2
But is it a cross sector or cross feeder case?!!
























All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

6

To confirm it as a cross sector case, moving towards sector 2 main beam.
In front of sector 2 main beam
You find sector 1 BCCH: 55, TCH: 21, 10 is serving with very good Rx-level in front of sector 2 main beam supposed
coverage region while sector 2 BCCH: 8 Rx-level is bad.




So, cross sector case is now confirmed between sectors 1 and 2 as sector 1 BCCH is serving in front of sector 2
coverage region which appears with very bad Rx-level, why?
Because the 2 GSM feeders of sector 1 BTS cabinet are connected wrong to sector 2 antenna, which means that
the 2 feeders [including TX/RX feeder] which carries sector 1 BCCH transmitted power is connected wrong to
sector 2 antenna so sector 2 antenna is actually the one generating the power for sector 1 BCCH not sector 1
antenna that's why you find BCCH of sector 1 with very good Rx-level in front of sector 2 antenna and with very
bad Rx-level in front of sector 1 antenna.
NOTE: Don't ever judge a cross case from 1 or 2 TEMS samples only also don't judge while you are under the site
as all site sectors will appear in good Rx-levels.

All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

7
2-DCS cross sector:
When the 2 feeders from DCS BTS 1st cabinet are connected to sector 2 antenna and the 2 feeders from DCS BTS
2nd cabinet are connected to sector 1 antenna.













NOTE: You can notice that the 2 GSM feeders in each sector are correctly configured in the sector antenna, as
cross can occur in a band while other band is correctly connected as we've said before.
NOTE: Whenever suspecting a cross case between any 2 sectors, try locking using TEMS on each sector BCCH and
move near and far around the suspected 2 sectors to see each sector Rx-levels are they logical and serving in the
sector supposed serving area or not.









All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

8
Example:
NOTE: Site in next example is concentric site where BCCH is in 900's band while TCHs are in 1800 DCS band.
As shown in the following snaps, suspecting a cross problem in site between sectors 1 and 2 as sector 2 BCCH: 47 is
serving with good Rx-level in front of sector 1 BCCH: 49 main beam which appears with bad Rx-level and vice versa.
So to confirm cross problem:
BEFORE CROSS SOLVED
Locking on sector 2 BCCH: 47
In front of sector 1 main beam
You find sector 2 BCCH:47,DCS TCH: 751,786 appear in [GSM Hopping Channels] window with non-logical very good
Rx-level in front of sector 1 main beam covering region however there Rx-levels were supposed to be bad as they
were not supposed to cover and serve there while sector 1 BCCH: 49 Rx-level is bad.






All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

9
In front of sector 2 main beam
You find sector 2 BCCH: 47, DCS TCH: 751,786 appear in [GSM Hopping Channels] window with non-logical very bad
Rx-level in front of sector 2 main beam covering region however there Rx-levels were supposed to be good as you
were in front of sector 2 antenna main beam so sector 2 levels were supposed to be good while sector 1 BCCH: 49
Rx-level is good.













All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

10

But what about sector 1 cabinet feeders, are they both correctly connected or what?
Locking on sector 1 BCCH: 49
In front of sector 1 main beam
You find sector 1 BCCH: 49, DCS TCH: 757,784,789 appear in [GSM Hopping Channels] window with non-logical bad
Rx-level in front of sector 1 main beam covering region however there Rx-levels were supposed to be good as you
were in front of sector 1 antenna main beam so sector 1 Rx-levels were supposed to be good while sector 1 BCCH: 49
Rx-level is good.
.








All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

11
In front of sector 2 main beam
You find sector 1 BCCH: 49,DCS TCH: 757,784,789 appear in [GSM Hopping Channels] window with non-logical very
good Rx-Level in front of sector 2 main beam covering region however there Rx-levels were supposed to be bad as
they were not supposed to cover and serve there while sector 2 BCCH: 47 Rx-level is bad.
.



So, cross sector case is now confirmed between sectors 1 and 2 as sector 1 BCCH is serving in front of sector 2
coverage region which appears with very bad Rx-level and vice versa.






All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

12

AFTER CROSS SOLVED
Trying same procedure by locking on sector 2 BCCH: 47
In front of sector 1 main beam
You can notice that sector 2 BCCH:47,DCS TCH: 751,786 appear in [GSM Hopping Channels] window with logical bad
Rx-level in front of sector 1 main beam covering region as sector 2 originally was not supposed to serve in front of
sector 1 antenna main beam while sector 1 BCCH: 49 Rx-level is very good.










All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

13
In front of sector 2 main beam
You can notice that sector 2 BCCH:47, DCS TCH: 751,786 appear in [GSM Hopping Channels] window with logical
good Rx-level in front of sector 2 main beam covering region while sector 1 BCCH: 49 Rx-level is bad.




Cross sector problem appeared to be solved as sector 2 BCCH:47 appears with good Rx-level in front of sector 2
antenna but decays and appears with bad Rx-level in front of sector 1 antenna.
But what about sector 1 feeders?






All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

14
Locking on sector 1 BCCH: 49
In front of sector 1 main beam
You can notice that sector 1 BCCH:49, DCS TCH: 757,784,789 appear in [GSM Hopping Channels] window with
logical good Rx-level in front of sector 1 main beam covering region while sector 2 BCCH: 47 Rx-level is bad.












All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

15
In front of sector 2 main beam
You can notice that sector 1 BCCH:49, DCS TCH: 757,784,789 appear in [GSM Hopping Channels] window with
logical very bad Rx-level in front of sector 2 main beam covering region as sector 1 originally was not supposed to
serve in front of sector 2 antenna main beam while sector 2 BCCH: 47 Rx-level is good.




Clearly cross sector problem is now solved, as each sector serves properly in front of its main beam and decays in
levels in front of the other sector's main beam.







All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

16
3-Total [GSM & DCS] cross sector:
When all the 4 feeders [both GSM 2 feeders and DCS 2 feeders] from sector 1 BTS cabinet are connected to sector 2
antenna and the other 4 feeders from sector 2 BTS cabinet are connected to sector 1 antenna.
Every sector cabinet is connected to the wrong other sector antenna.












NOTE: Once you notice on TEMS that a sector antenna is serving on its non-main beam, you then suspect 1 of 2
problems:
1-This sector antenna has wrong azimuth whether in reality or cell file.
2-Site suffers from a cross problem.
But, why we shall solve cross sector problem in sites?
As it may cause problems like:
Congestion which may causes blocked calls.
Missing neighbor problem.
Down-link interference [Co. or adjacent channel interference].
Dropped calls due to the last 2 before mentioned reasons.




All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

17
2-2G Cross Feeders;
When 2 sectors S1 and S2 are both serving in 1 side with almost the same good Rx-levels in window [GSM Serving +
Neighbors] which may causes ping pong H.O while both have very bad Rx-levels in the other side where none of
them is serving at all as you find very bad Rx-levels from both of their BCCHs [same behavior from 2 sectors] in 2
sides.
Imagine 2 BTS cabinets S1 and S2 each is connected to its correct sector antenna through 2 feeders TX/RX 1
st
feeder
and RX 2
nd
feeder, if by mistake 1 of these 2 feeders [Not both] is connected to the wrong sector antenna, it will be a
cross feeders case.












NOTE: Whenever suspecting a cross case between any 2 sectors, try locking using TEMS on each sector BCCH and
move near and far around the suspected 2 sectors to see each sector levels are they logical and serving in the
sector supposed serving area or not.
As we've said before a cross case can occur in 1 band only GSM or DCS and don't have to affect the other band.
There are 2 types of cross feeders:
GSM cross feeders.
DCS cross feeders.





All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

18
1-GSM cross feeders:
We can say that there are 3 possibilities for this wrong connection:
Case 1 [Most famous case in cross feeders]:
When the TX/RX feeder from GSM BTS 2nd cabinet is connected wrong to sector 1 antenna or vice versa, where
sector 1 antenna will be transmitting both sector 1 and sector 2 BCCHs power.
The other sector 2 antenna will include the 2 RX diversity feeders with no transmitted power from BTS cabinets in
them.













Example:
As shown in the following snaps, suspecting a cross problem in site between sectors 2 and 3 in GSM as both sector 2
BCCH: 42 and sector 3 BCCH: 35 appears with almost same good Rx-level in front of sector 3 main beam in [GSM
Serving + Neighbors] window while both appears with very bad Rx-level in front of sector 2 main beam.







All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

19

BEFORE CROSS SOLVED
In front of sector 3 main beam
You find both sector 2 BCCH: 42 and sector 3 BCCH: 35 appear in [GSM Serving + Neighbors] window with very good
Rx-level which may causes Ping-Pong H.O as both the TX/RX feeders from the 2 BTS cabinets are connected to
sector 3 antenna where all the 2 sector's BCCHs power will be transmitted by sector 3 antenna.










All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

20
In front of sector 2 main beam
You find sector 2 BCCH: 42 serving with very bad Rx-level which is normal, why?
Because the 2 feeders connected to sector 2 antenna now are the up-link RX diversity feeders.





So in 1 area coverage from site 2 sectors are very good as both 2 sectors are serving there while the other area
suffers very bad coverage as none of them is serving at all, so cross feeders now is confirmed.







All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

21

AFTER CROSS SOLVED
In front of sector 3 main beam
You find sector 2 BCCH: 42 appears with normal bad Rx-Level because now the TX/RX feeder carrying the power for
BCCH: 42 is not connected to sector 3 antenna but it is connected to sector 2 antenna as it should be.











All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

22
In front of sector 2 main beam
You find sector 2 BCCH: 42 is serving with good normal Rx-level as now the TX/RX feeder is connected to sector 2
antenna, so coverage in the area is clearly enhanced now.




Clearly cross feeders problem is now solved, as each sector serves properly in front of its main beam and decays in
levels in front of the other sector's main beam so coverage in both sectors area is now enhanced.







All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

23
Case 2 [Cross sector case]:
When the TX/RX feeder from GSM BTS 2nd cabinet is connected wrong to sector 1 antenna and the TX/RX feeder
from GSM BTS 1st cabinet is connected wrong to sector 2 antenna.
Sector 1 antenna will be transmitting sector 2 BCCH and TCHs, while sector 2 will be transmitting sector 1 BCCH and
TCHs.













In field, you find each sector serves in the other sector supposed coverage region while the other non-serving sector
appears with bad levels [S1 serves in front of S2 region and vice versa].
NOTE: To name a case a cross sector case both the 2 feeders [TX/RX and RX feeder] should be both connected to
the wrong sector antenna, but if this specific TX/RX feeder which carries the transmitted power from BTS cabinet
to antenna only is connected to wrong antenna it will appear in the field as a cross sector case not cross feeder
even if the RX feeder is connected to the correct sector antenna.








All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

24
Case 3 [Cross in Rx diversity]:
When both RX feeders from BTS cabinets are cross connected to each other antennas, this case is named cross
diversity.
Both sector antennas will not be transmitting any BCCHs power.










Nothing will be detected in the field on TEMS as it shows only the down-link signal received by MS and cross
diversity problem affects only the up-link, but it will be noticed by optimizers through site KPI's.
1-DCS cross feeders:
It follows the same 3 cases of GSM cross feeders.








All about DT [Drive-Test] problems

By: Abdelrahman Ashraf Mostafa

25

But, why we shall solve cross feeders problem in sites?
As it may cause problems like:
Bad coverage as in case 1 as 1 area has good coverage while the other area suffers very bad coverage from
serving site.
Blocked calls.
Down-link interference [Co. or adjacent channel interference] on neighboring sites.
Dropped calls due to bad coverage or Ping-Pong H.O.










That's all about the 2G field radio problems
But,
Stay tuned for 3G Problems [Part 3] which will be about 3G DT field problems.
Thanks & good luck for you all.
For any questions, contact me on my e-mail or phone.

WWW.ERICSSON.COM

Вам также может понравиться