Вы находитесь на странице: 1из 24

Air Handling Units

BWY Series
Chilled/Hot water
BWY03 thru BWY25
3 TR thru 30 TR
10 KW thru 100 KW

Company Business
Zamil Air Conditioners was founded in 1974 as one of the first air conditioning business to be established in Saudi Arabia
and today is a leading international manufacturer of air conditioning systems and is No. 1 in the Middle East.
Zamil Air conditioners manufactures both consumer and central air conditioners and has sales operations in over 55
countries in the Middle East, Europe, Africa and Asia.
The companys operations are structured into four Strategic Business Units (SBUs) supporting five in-house product and
service brands as well as a number of international brands under the OEM sales.
The five in-house brands are Classic, Cooline, CoolCare, Clima Tech and Geoclima.
The four SBUs are:
1. Consumer Business Unit supporting Classic, Cooline, GE and OEM brands for consumers.
2. Unitary & Applied Business Unit supporting Classic, Cooline, GE and OEM brands for commercial and industrial
customers.
3. Zamil CoolCare providing engineering & project management services, HVAC maintenance, retrofit services and parts.
4. Geoclima srl is an independent business supporting other SBUs for their requirement of Chillers & Double skin AHUs.
The first three SBUs - Consumer Products, Unitary & Applied Products and CoolCare Service direct their business
operations from the corporate headquarters at Dammam, Saudi Arabia.
Geoclima has its engineering & production departments located at Monfalcone, Italy and has a design center in Austria.
All the four SBUs, while operating independently, supplement each others activities in a way that makes synergy work at
its best and achieve the corporate goals of maximizing customer satisfaction.
Factories and Productions
Zamil Air Conditioners has two manufacturing plants in Dammam, Saudi Arabia and has one speciality production facility
in Italy operated by Geoclima.
The company can produce up to 550,000 Room Air Conditioners, 300,000 Mini-Split systems and 50,000 Central Air
Conditioning systems per year.
Quality & Product Certificates
The Quality systems and policies at Zamil Air Conditioners comply with the required ISO 9001:2000 certification.
Zamil Air Conditioners is the first company in Saudi Arabia to receive the SASO (Saudi Arabias Standard Organization)
Certificate for Room Air Conditioners. ZAC's products are also certified with:
1. CE (Council of European Community)
2. UL (Underwriters Laboratory)
3. Eurovent
4. DEMKO
5. ETL
Other awards include the prestigious Engineering Excellence Award of General Electric and the inaugural Prince Mohammed
bin Fahd Al Saud Award for Factory Safety.
Our Products
In addition to the consumer products such as the Room Air Conditioners (RAC) and the Mini Splits, Zamil Air Conditioners
manufacturers a host of residential, commercial and industrial air conditioners. This broad range extends from the Concealed Units up to 5 tons, the Ducted Splits up to 30 tons, the Packaged Units up to 90 tons, the Single and Double Skin
Air Handling Units up to 70,630 CFM and the Water Chillers up to 660 tons cooling capacity.

INDEX
Contents

Page

Outstanding features ................................................................................................................................ 2


Model decoding ........................................................................................................................................ 3
Blower drive options ................................................................................................................................. 4
Standard specifications ............................................................................................................................ 4
Options and accessories .......................................................................................................................... 5
Physical data ............................................................................................................................................ 6
Cooling capacities ................................................................................................................................. 7-8
Fan performance data ......................................................................................................................... 9-10
Electrical data .................................................................................................................................... 11-13
Dimensions ........................................................................................................................................ 14-17
Dimensions, heater box .......................................................................................................................... 18
Typical schematic wiring diagram ........................................................................................................... 19
Controls and sequence of operation ....................................................................................................... 20
Installation instructions ........................................................................................................................... 21
Recommended spare parts .................................................................................................................21

CONTINUING RESEARCH RESULTS IN STEADY IMPROVEMENTS.


THEREFORE, THESE SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

OUTSTANDING FEATURES
* INDEPENDENT HORIZONTAL OR VERTICAL AIR DISCHARGE UNITS
* LOW CEILING HEIGHT REQUIREMENTS
* CHILLED & HOT WATER COILS
* ONE SIDE TOTAL SERVICE ACCESSIBILITY
* SINGLE POINT POWER ENTRY
* UV FLOW LIGHT EMITTERS FOR ENHANCED IAQ (INDOOR AIR QUALITY)
* NUMBER CODED WIRES
* INSULATED DRAIN PAN
* FACTORY INSTALLED OPTIONS UPON REQUEST
* SMALL FOOTPRINT
* LIGHT WEIGHT
* PRE-PAINTED CABINETS WITH FIBERGLASS INSULATION
* LARGE CHOICE OF HEATERS; FACTORY OR FIELD INSTALLATION
* STANDARD OR OPTIONAL MOTORS; FACTORY OR FIELD INSTALLATION
* ALUMINUM OR SYNTHETIC FILTERS
* UL LISTED MAJOR COMPONENTS

V : VERTICAL

H : HORIZONTAL

NOTES:

25

18

14

10

07

V : VERTICAL

H : HORIZONTAL

4&5
6
FACE AREA ARRANGEMENT
(SQ. FT.)

9
BLOWER
MOTOR

8
COIL APPLICATION

9
BLOWER
MOTOR

F : 460-3-60

D : 3 ROW CHILLED
WATER + 1 ROW
HEATING SPLIT COIL

FOR BWY25
J : 7.5 HP ODP
L : 10 HP ODP

FOR BWY14/18
G : 5 HP ODP
J : 7.5 HP ODP

C : STD. 4 ROW CHILLED FOR BWY10


D : 2 HP ODP
WATER COIL
E : 3 HP ODP

H : 208/230-3-60 A : STD. 3 ROW CHILLED FOR BWY07


WATER COIL
D : 2 HP ODP
B : 2 ROW CHILLED
M : 380-3-60
E : 3 HP ODP
WATER
+
1
ROW
(4 WIRE)
HEATING SPLIT COIL

7
ELECTRICAL
SUPPLY
(V-Ph-Hz)

Blower motor ON/OFF and trip indication.

AIR HANDLING
UNIT
(CHILLED WATER)

BWY

1, 2 & 3
BASIC

8
COIL APPLICATION

A : STD. 3 ROW CHILLED U : 0.5 HP ODP


WATER COIL
H : 208/230-3-60
W : 0.75 HP ODP
B : 2 ROW CHILLED
W : 0.75 HP ODP
WATER + 1 ROW
M : 380-3-60
(4 WIRE)
HEATING SPLIT COIL
Y :1 HP ODP
F : 460-3-60
C : 208/230-1-60

7
ELECTRICAL
SUPPLY
(V-Ph-Hz)

K : ALT. II

J : ALT. I

10
DRIVE
OPTIONS

N : DIRECT
DRIVE

10
DRIVE
OPTIONS

**

12
COIL FINS

C : COPPER FIN

B : COATED
ALUMINUM
FIN

A : ALUMINUM
FIN

12
COIL FINS

: NO HEATER A : ALUMINUM
: 5/1
FIN
: 6/1
: 7.5 /1
B : COATED
: 10 /2
ALUMINUM
: 12/2
FIN
: 15 /2
: 20 /2
C : COPPER FIN
: 25/2
: 30/2
FOR BWY18/25
N : NO HEATER
E : 12/2
F : 15 /2
G : 20 /2
H : 25/2
J : 30/2
K : 35/2
L : 40/2

N
A
B
C
D
E
F
G
H
J

11
HEATER
OPTIONS
(kW/STAGE)

C : 7.5 /1

B : 6/1

A : 5/1

N : NO HEATER

11
HEATER
OPTIONS
(kW/STAGE)

MODEL DECODING

Blower motor ON/OFF and trip indication.


Heater capacity will be 7kW for single phase power supply.

05

03

4&5
6
FACE AREA ARRANGEMENT
(SQ. FT.)

MODELS: BWY07 - BWY25

*
**

NOTES:

AIR HANDLING
UNIT
(CHILLED WATER)

BWY

1, 2 & 3
BASIC

MODELS: BWY03 - BWY05


15
OTHER
OPTIONS

14
UNIT
ACCESSORIES

15
OTHER
OPTIONS

V : VOLT FREE
CONTACTS*

N : STD. UNIT.
N : STD. UNIT
NO ACCESORIES

14
UNIT
ACCESSORIES

B : 2" ALUMINUM
D : 2"SYNTHETIC

FOR BWY25
N : NO FILTER

A : 1" ALUMINUM
B : 2" ALUMINUM
C : 1" SYNTHETIC
D : 2"SYNTHETIC

N : NO FILTER

FOR BWY10, 14 & 18

N : STD. UNIT.
N : STD. UNIT
FOR BWY07
NO ACCESORIES
N : NO FILTER
E : 1/2" ALUMINUM
V : VOLT FREE
F : 1/2" SYNTHETIC
CONTACTS*
A : 1" ALUMINUM
C : 1" SYNTHETIC

13
FILTER

C : 1" SYNTHETIC

A : 1" ALUMINUM

F : 1/2" SYNTHETIC

E : 1/2" ALUMINUM

N : NO FILTER

13
FILTER

BLOWER DRIVE OPTIONS


MOTOR
MODEL
NUMBER

BWY07
BWY10
BWY14
BWY18
BWY25

OPTION
ALT. I
ALT. II
ALT. I
ALT. II
ALT. I
ALT. II
ALT. I
ALT. II
ALT. I
ALT. II

HP

RPM

2
3
2
3
5

1750
1750
1750
1750
1750
1750
1750
1750
1750
1750

7.5
5
7.5
7.5
10

BLOWER
PULLEY
PITCH DIA.
(INCH)
2.7 - 3.7
2.7 - 3.7
3.1 - 4.1
3.1 - 4.1
3.7 - 4.7
4.3 - 5.5
3.7 - 4.7
4.3 - 5.5
4.3 - 5.5
4.3 - 5.5

SPEED RANGE (RPM)


MINIMUM

MAXIMUM

893
964
733
875
809
940
809
875
800
800

1156
1321
970
1157
1028
1203
1028
1120
1023
1023

PULLEY
PITCH DIA.
(INCH)
5.6
4.9
7.4
6.2
8.0
8.0
8.0
8.6
9.4
9.4

APPROX. SPEED
CHANGE PER
PULLEY
TURN (RPM)
62
71
40
47
37
44
37
40
44
44

STANDARD SPECIFICATIONS
A. General
These Air Handling Units are factory fabricated and assembled, consisting of forward-curved fan section with blower
motor, chilled/hot water coil, electric heaters (optional), filters & electrical control box and are suitable for indoor applications. The unit is ready to operate when connected to piping, power/controls and air ducts or plenums.
They should be ordered separately as horizontal air discharge or vertical air discharge units as per application requirements.

B. Unit Enclosure
Casing Panels are of heavy gauge (G-90) galvanized steel. Removable access panels are provided for inspection and
access to all internal parts. These panels are insulated with 1/2" thick fiberglass insulation to prevent condensation from
forming on the unit casing. Insulation meets the requirements of NFPA 90A and is protected against deterioration and
errosion from air currents. Steel sheet is zinc-coated, galvanized by the hot dip process of lock forming quality conforming to ASTM A 653 commercial weight G-90, followed by baked-on electrostatic polyester dry powder coat.

C. Coils
Coils are of the enhanced louvered fin-and-tube type, constructed of seamless copper tubes, mechanically bonded to
aluminum fins. As an option, corrugated copper or enhanced coated aluminum fins may be provided.
The standard chilled water coil is 3 row for BWY03, BWY05 & BWY07 and 4 row for BWY10 & above. For heating
application, the coils are split as 2 row chilled water + 1 row hot water for BWY03, BWY05 & BWY07 and 3 row chilled
water + 1 row hot water for BWY10 & above. End plates and tube support sheets are 18 gauge galvanized steel, formed
to provide structural strength.
Each coil is pressure tested in the factory at not less than 300 psi (2070 kPa) air pressure. Coils conform to ARI 410.

D. Drain Pans
Drain pans provided under cooling coil section are made of G-90 galvanized steel with mastic coated liner for additional
corrosion protection and the outer surface is thermally insulated. Drain outlets of 3/4" NPT is provided for field connection.

E. Evaporator Fan
Evaporator fan is of a centrifugal forward-curved blade design and sized to meet system airflow/pressure. Fan motor
(except for BWY03 & BWY05, which have direct drive motors) is mounted on an adjustable base and secured by a
locking device. Fan drive is through adjustable motor pitch pulley and belt-driven. Fan shafts are designed to operate at
less than 2/3rds of the first critical speed when the unit comes up to rated revolutions per minute (RPM). Units have
sealed, permanently lubricated ball or sleeve fan bearing and are statically / dynamically balanced in the fan housing
during final assembly. Fan motors are of the open drip-proof type (totally enclosed types are optional, for belt driven
only) and conform to NEMA MG-1 & MG-2. Motor starters are magnetic contactor, across-the-line type.

OPTIONS AND ACCESSORIES


A. Zone Control
Total comfort zone control systems are available up to 19 zones and can provide a comfortable temperature to each
zone/room (field supplied).

B. Electric Heaters
Electric heaters are of the resistance open coil type and conform to the requirements of UL 573 or equivalent. Electrical
characteristics, kW capacities and number of stages are as indicated. Thermal cut-outs, fusible links and airflow switches
are provided to shut-off power to heaters in case of airflow failure.

C. Filters
Filters are easily accessible through the filter access panel. Filters may be synthetic or permanent washable aluminum type, one or two inch
thick (refer to model decoding for details). As an accessory, bag filter section can be provided for belt driven units (BWY07 - BWY25).

D. Discharge Air Plenum & Return Air Grille


As an accessory, discharge air plenum with return air grilles can be provided on vertical units.

E. UV Flow Light Emitters


The damp & dark environment inside the AHU is ideal for the growth and development of hazardous bacteria & fungi. The UV
flow concept uses emitters of Ultra Violet light to simulate the effect of healthy sun radiation. This will inhibit the growth of these
microorganisms reducing in this manner mold related allergies and diseases. Breath safely with UV flow.
To order the UV flow use the kit numbers in the table below.
MODEL NUMBER
KIT PART NUMBER

BWY03

BWY05

BWY07

BWY10

BWY14

BWY18

BWY25

700-391-16

700-391-17

700-391-18

700-391-19

700-391-20

700-391-21

700-391-22

F. Electronic Thermostats
General Informations: Single stage or two stage thermostats provide low voltage control of one or two stage heating and/or
cooling applications. The thermostat normally displays room temperature, mode of operation and which system is currently on.
You may select different heating and cooling setpoints for the systems to maintain (example 700F in heating and 750F in
cooling). Raising or lowering the setpoints in heating or cooling is as simple as pushing a button.
The thermostat also allows you to select continuous fan operation, (useful when using an electronic air cleaner), or have
the fan on intermittent operation with the equipment.
The thermostat is best located about 1500 mm (5 Ft.) above floor level, on a partition wall (not an outside wall), and should not
be exposed to direct light from lamps, sun etc. It should be in return air stream, away from supply air registers /diffusers.
TYPICAL THERMOSTAT
Part No.

Heating Cooling
Stages Stages

Selector Switch Positions


Mode Switch

Fan Switch

800-645-31

OFF-AUTO - HEAT/COOL ON - AUTO

800-645-21*

OFF-AUTO - HEAT/COOL ON - AUTO

800-646-23

OFF-AUTO - HEAT/COOL ON - AUTO

* with built-in compressor fault & clogged filter indication led lights.

TYPICAL THERMOSTAT
5

PHYSICAL DATA
MODEL NUMBER

BWY03

BWY05

BWY07

EVAPORATOR BLOWER Type

BWY25

1200 (566) 2000 (944) 3000 (1416) 4600 (2171) 5500 (2596) 7000 (3303) 9000 (4247)

Motor HP, Std./Alt.

0.5/0.75

0.75/1

2/3

3/2

5/7.5

5/7.5

7.5/10

Drive type

Direct

Direct

Belt

Belt

Belt

Belt

Belt

Blower size

10x10

10x10

12x12

15x15

15x15

15x12

18x18

Corrugated Fin & Tube, 3/8" dia tube, 14 FPI

Type

Rows, split (chilled + hot water)


Face area, Sq. ft. (Sq. m.)

SHIPPING WEIGHT

BWY18

Nominal airflow, CFM (L/S)

Rows, std. chilled water

RETURN AIR FILTER

BWY14

Centrifugal

Quantity
EVAPORATOR COIL

BWY10

2+1

2+1

2+1

3+1

3+1

3+1

3+1

7 (0.65)

10 (0.93)

3.2 (0.3) 4.5 (0.42)

14 (1.3) 17.5 (1.62) 25 (2.32)

Water in/out size, MPT (inch) Chilled water

3/4

1-1/4

1-1/2

1-1/2

1-1/2

1-1/2

Water in/out size, MPT (inch) Hot water

3/4

1-1/4

1-1/4

1-1/4

1-1/2

Condensate drain connection (inch)

3/4

3/4

3/4

3/4

3/4

3/4

3/4

20 x 24 x 1

20 x 24 x 1

20 x 24 x 2

Size (inch)

24 x 20 x 1/2 16 x 20 x 1/2 20 x 20 x 1/2 18 x 24 x 1

Quantity

kg. (approx.)

80

120

165

225

300

340

420

HOT WATER CAPACITIES


EWT - 1500F (650C)

EWT - 1800F (820C)

MODEL
NUMBER

GPM (LPS)

CAPACITIES
MBH (kW)

GPM (LPS)

CAPACITIES
MBH (kW)

BWY03

2.5 (0.16)

24.7 (7.23)

4 (0.25)

38.5 (11.3)

BWY05

3.8 (0.24)

36.5 (10.7)

6 (0.38)

57.7 (16.9)

BWY07

5.7 (0.36)

56.2 (16.5)

9 (0.57)

89.2 (26.1)

BWY10

8.1 (0.51)

80.4 (23.5)

13 (0.81)

128.3 (37.6)

BWY14

11.6 (0.73)

113.4 (33.2)

18 (1.13)

177 (51.8)

BWY18

14 (0.90)

138 (40.4)

22 (1.40)

218 (63.8)

20 (1.26)

194.3 (56.9)

31 (1.95)

304 (89)

BWY25

NOTE: Capacities @ 70 F (21 C) Entering Air Temperature & 20 F (11 C) Water Temperature Drop.
0

LEGEND: EWT - Entering Water Temperature; MBH - 1000 BTUH; GPM - Gallons Per Minute; LPS - Liters Per Second

CHILLED WATER COOLING CAPACITIES


STANDARD COIL
ENTERING AIR TEMP. = 760F DB/650F WB
0

ENTERING AIR TEMP. = 800F DB/670F WB

0
45 F EWT

40 F EWT

0
50 F EWT

WTR
0
F

UNIT
SIZE

TC

SC

GPM

TC

SC

GPM

TC

SC

GPM

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

37.87
61.29
97.68
165.61
212.95
282.70
390.34

23.64
38.37
60.84
102.19
130.60
172.69
236.86

9.46
15.32
24.42
41.40
53.24
70.67
97.58

30.59
49.28
77.28
131.67
169.61
223.23
307.49

20.55
33.26
51.86
87.23
111.30
145.85
199.09

7.65
12.32
19.32
32.92
42.40
55.81
76.87

24.37
38.95
60.71
103.05
131.18
170.46
231.68

18.54
29.87
46.22
77.16
97.03
125.64
169.10

6.09
9.74
15.18
25.76
32.79
42.61
57.92

10

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

35.99
57.86
90.57
152.98
196.88
258.49
355.94

22.58
35.78
56.78
95.08
121.53
159.22
217.76

7.20
11.57
18.11
30.60
39.37
51.70
71.19

29.80
47.59
74.15
125.95
160.32
208.21
282.91

20.09
32.26
50.03
83.93
106.04
137.29
185.25

5.96 23.71 18.14 4.74


9.52 37.61 28.98 7.52
14.83 58.33 44.74 11.66
25.19 99.70 75.06 19.94
32.06 126.92 94.46 25.38
41.64 163.94 121.66 32.79
56.58 222.31 163.45 44.46

12

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

35.23
56.24
87.60
148.85
189.47
245.97
334.17

22.14
35.47
54.92
92.77
117.38
152.16
205.75

5.87
9.37
14.60
24.81
31.58
40.99
55.69

29.14
46.25
71.77
122.60
156.06
201.69
273.54

19.70
4.86 23.12 17.76 3.85
31.44
7.71 36.47 28.24 6.08
48.62 11.96 56.39 43.46 9.40
81.96 20.43 96.94 73.32 16.16
103.49 26.01 123.47 92.41 20.58
133.55 33.61 158.86 118.69 26.48
179.83 45.59 215.17 159.08 35.86

0
40 F EWT

0
45 F EWT

0
50 F EWT

WTR
0
F

UNIT
SIZE

TC

SC

GPM

TC

SC

GPM

TC

SC

GPM

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

47.30
77.63
124.79
208.72
268.25
360.07
491.2

29.43
48.35
77.23
128.14
163.51
218.37
298.1

11.82
19.41
31.20
52.18
67.06
90.02
121.0

39.53
64.16
102.39
173.15
222.61
296.09
409.10

26.17
42.63
67.52
112.65
143.44
189.60
259.51

9.88
16.04
25.60
43.29
55.65
74.02
102.27

31.96
51.58
81.08
138.95
178.89
235.88
325.04

23.53
38.15
59.52
99.94
126.99
166.38
226.37

7.99
12.89
20.27
34.74
44.72
58.97
81.26

10

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

44.35
71.52
113.74
193.61
249.05
329.72
454.86

27.76
43.85
71.02
119.71
152.92
201.68
276.33

8.87
14.30
22.75
38.72
49.81
65.94
90.97

37.35
60.13
94.23
159.91
206.06
270.95
373.16

24.92
40.27
62.78
105.18
134.16
175.67
239.74

7.47
12.03
18.84
31.98
41.21
54.19
74.63

31.14
49.80
77.67
131.76
167.72
218.07
296.47

23.01
37.06
57.42
95.73
120.43
155.99
209.98

6.23
9.96
15.53
26.35
33.54
43.61
59.29

12

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

42.76
68.72
107.54
181.69
233.36
306.28
421.72

26.28
43.30
66.16
113.03
144.14
188.70
258.06

7.13
11.45
17.92
30.28
38.89
51.05
70.29

36.57
58.45
91.10
154.64
196.85
255.80
347.67

24.46
39.28
60.97
102.14
128.98
167.16
225.48

6.09
9.74
15.18
25.77
32.81
42.63
57.94

30.46
48.41
75.17
128.25
163.25
211.18
286.51

22.59
36.20
55.86
93.60
117.90
151.94
204.19

5.07
8.07
12.53
21.37
27.21
35.20
47.75

ENTERING AIR TEMP. = 840F DB/690F WB


0
40 F EWT

0
45 F EWT

0
50 F EWT

WTR
0
F

UNIT
SIZE

TC

SC

GPM

TC

SC

GPM

TC

SC

GPM

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

56.99
94.75
153.80
254.16
326.78
437.20
605.20

35.17
58.49
94.25
154.60
197.38
263.60
360.60

14.25
23.69
38.45
63.54
81.69
109.10
149.00

49.01
80.62
129.82
216.65
278.45
374.52
510.00

31.89
52.54
83.87
138.36
176.04
235.07
321.50

12.25
20.15
32.45
54.16
69.61
93.63
126.00

41.21
67.04
107.16
180.76
232.35
309.66
428.14

29.24
47.76
75.48
125.13
158.78
209.78
286.00

10.30
16.76
26.79
45.19
58.09
77.41
107.03

10

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

53.71
87.60
140.25
235.97
303.30
405.03
560.45

33.34
54.49
86.72
144.60
184.55
245.25
336.96

10.74
17.52
28.05
47.19
60.66
81.01
112.09

46.01
74.35
118.38
201.06
258.57
342.85
473.19

30.20
48.97
77.39
129.71
165.16
217.76
297.69

9.20
14.87
23.68
40.21
51.71
68.57
94.64

38.72
62.41
97.91
167.16
215.30
283.51
390.57

27.76
45.01
70.05
117.40
149.14
195.21
265.58

7.74
12.48
19.58
33.43
43.06
56.70
78.11

12

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

50.85
81.77
129.88
221.71
285.29
377.02
519.84

31.73
51.21
79.83
136.62
174.59
229.86
314.87

8.47
13.63
21.64
36.95
47.55
62.84
86.64

44.12
70.98
111.18
188.16
242.53
318.70
438.88

29.10
7.35 37.91 27.28 6.32
47.04 11.83 60.66 43.97 10.11
73.25 18.53 94.63 68.12 15.77
122.43 31.36 160.46 113.46 26.74
156.25 40.42 204.27 142.92 34.04
204.48 53.11 265.70 185.04 44.28
278.96 73.15 361.03 249.00 60.17

NOTE:
1. Capacities are based on nominal airflow.
2. For any other conditions, please use selection software for fan coil units.
Apart from capacities, this software provides;
a) Sensible heat ratio
b) Leaving air temperature (DB/WB) - 0F
c) Leaving water temperature - 0F
d) Water pressure drop (feet of water)

LEGEND:

0
40 F EWT

0
45 F EWT

GPM - Water flow (Gallons Per Minute)

0
50 F EWT

TC

SC

GPM

TC

SC

GPM

TC

SC

GPM

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

35.0
53.8
85.4
172.5
230.1
296.3
386.1

22.5
34.6
54.7
107.8
142.5
183.0
238.8

8.8
13.5
21.4
43.0
57.5
74.0
81.5

29.7
44.7
71.7
143.2
191.0
245.0
335.0

20.6
31.0
49.3
95.5
126.0
161.0
219.0

7.5
11.2
18.0
36.0
48.0
62.0
81.0

23.5
34.8
56.1
115.3
153.0
194.4
268.8

18.4
27.4
43.7
85.6
112.0
142.0
194.7

6.0
8.7
14.2
29.0
38.5
49.0
67.0

10

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

32.9
49.2
79.3
159.6
213.0
272.4
377.4

21.2
31.9
51.0
100.4
133.0
169.6
233.8

6.6
9.8
16.0
32.0
42.8
55.0
75.5

26.4
39.4
62.3
132.4
178.1
223.0
308.1

18.5
27.7
43.5
89.1
118.5
148.3
203.6

5.3
7.9
12.5
26.7
35.8
45.0
61.5

20.0
28.8
45.4
103.8
139.6
174.2
245.2

16.0
23.1
36.4
78.5
103.8
129.6
180.5

4.1
5.8
9.1
21.0
28.0
35.0
49.0

12

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

29.7
43.8
69.4
149.2
200.1
251.0
353.4

19.4
28.6
45.1
94.5
122.7
154.4
220.3

5.0
7.3
11.6
25.0
33.5
42.0
59.0

23.2
32.4
52.1
120.0
162.2
203.0
286.1

16.5
23.1
37.0
81.8
109.1
136.5
190.9

4.0
5.4
8.7
20.0
27.0
34.0
47.8

19.5
21.8
25.6
89.9
124.4
154.6
217.8

15.6
18.1
21.7
69.5
94.3
117.3
163.5

3.9
4.0
4.8
15.0
20.8
26.0
36.5

- Sensible Heat Capacity (MBH)

EWT - Entering Water Temperature (0F)

ENTERING AIR TEMP. = 800F DB/670F WB


UNIT
SIZE

- Total Capacity (MBH)

SC

WTR - Water Temperature Rise (0F)

SPLIT COIL*
WTR
0
F

TC

2 Row coil for BWY03, BWY05 & BWY07. 3 Row coil for BWY10 & above.

E
N
G
L
I
S
H
U
N
I
T
S

M
E
T
R
I
C

CHILLED WATER COOLING CAPACITIES


STANDARD COIL
0

ENTERING AIR TEMP. = 270C DB/19.50C WB

ENTERING AIR TEMP. = 25 C DB/18.3 C WB


0

U
N
I
T
S

4 C EWT

7 C EWT

10 C EWT

WTR
0
C

UNIT
SIZE

TC

SC

LPS

TC

SC

LPS

TC

SC

LPS

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

10.96
17.61
27.95
47.78
61.49
81.20
111.94

7.09
11.42
18.03
30.51
39.01
51.31
70.27

0.52
0.84
1.34
2.28
2.94
3.88
5.35

8.92
14.31
22.36
37.83
48.16
62.95
86.67

6.25
10.06
15.65
26.15
33.02
42.98
58.63

0.43
0.68
1.07
1.81
2.30
3.01
4.14

6.97
11.10
17.25
29.39
37.41
48.44
65.75

5.63
9.02
13.94
23.31
29.30
37.82
50.82

0.33
0.53
0.82
1.40
1.79
2.31
3.14

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

10.68
17.12
26.76
45.28
57.65
75.30
103.67

6.92
11.13
17.33
29.06
36.79
47.93
65.55

0.43
0.68
1.07
1.80
2.30
3.00
4.13

8.73
13.91
21.63
36.82
46.87
60.75
82.48

6.12
9.81
15.19
25.53
32.23
41.68
56.18

0.35
0.55
0.86
1.47
1.87
2.42
3.28

6.81
10.78
16.69
28.60
36.42
46.95
63.62

5.52
8.80
13.57
22.79
28.70
36.87
49.48

0.27
0.43
0.66
1.14
1.45
1.87
2.53

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

10.48
16.72
26.02
44.26
56.33
73.07
99.23

6.80
10.89
16.89
28.47
36.03
46.64
63.02

0.36
0.57
0.89
1.51
1.92
2.49
3.39

8.56
13.57
21.04
35.99
45.81
59.15
80.20

6.02
9.61
14.83
25.03
31.61
40.73
54.84

0.29
0.46
0.72
1.23
1.56
2.02
2.74

6.66
10.49
16.21
27.91
35.56
45.70
61.88

5.42
8.61
13.23
22.33
28.14
36.11
48.37

0.23
0.36
0.55
0.95
1.21
1.56
2.11

0
4 C EWT

0
7 C EWT

0
10 C EWT

WTR
0
C

UNIT
SIZE

TC

SC

LPS

TC

SC

LPS

TC

SC

LPS

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

13.91
22.67
36.27
61.08
78.52
104.76
144.91

8.72
14.24
22.64
37.81
48.28
64.14
88.11

0.66
1.08
1.73
2.92
3.75
5.01
6.92

11.48
18.50
29.41
50.11
64.47
85.29
117.63

7.69
12.44
19.64
33.01
42.04
55.32
75.61

0.55
0.88
1.40
2.39
3.08
4.08
5.62

9.35
15.02
23.50
39.71
50.94
66.85
92.04

7.00
11.31
17.58
29.19
36.94
48.21
65.55

0.45
0.72
1.12
1.90
2.43
3.19
4.40

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

13.16
21.15
33.57
57.37
73.84
97.51
134.42

8.29
13.37
21.11
35.73
45.67
60.09
82.31

0.52
0.84
1.34
2.28
2.94
3.88
5.35

11.10
17.83
27.90
47.16
60.37
79.19
109.04

7.47
12.05
18.75
31.31
39.74
51.89
70.79

0.44
0.71
1.11
1.88
2.40
3.15
4.34

9.15
14.60
22.73
38.64
49.18
63.82
86.69

6.87
11.05
17.09
28.53
35.90
46.41
62.42

0.36
0.58
0.91
1.54
1.96
2.54
3.45

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

12.86
20.65
32.30
54.60
69.80
91.54
126.03

8.12
13.08
20.37
34.15
43.39
56.73
77.64

0.44
0.70
1.10
1.86
2.38
3.12
4.30

10.90
17.41
27.12
46.08
58.65
76.16
103.47

7.35
11.81
18.30
30.68
38.74
50.17
67.69

0.37
0.59
0.93
1.57
2.00
2.60
3.53

8.98
14.25
22.11
37.77
48.08
62.13
84.27

6.76
10.83
16.71
28.00
35.26
45.43
60.99

0.31
0.49
0.75
1.29
1.64
2.12
2.88

ENTERING AIR TEMP. = 290C DB/20.50C WB


0
4 C EWT

0
7 C EWT

0
10 C EWT

WTR
0
C

UNIT
SIZE

TC

SC

LPS

TC

SC

LPS

TC

SC

LPS

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

16.42
27.05
43.59
72.66
93.39
125.73
172.00

10.22
16.84
26.96
44.59
56.94
76.24
103.80

0.78
1.29
2.08
3.47
4.46
6.01
9.00

13.95
22.73
36.37
61.24
78.72
105.05
145.31

9.19
15.01
23.82
39.62
50.43
66.87
89.97

0.67
1.09
1.74
2.93
3.76
5.02
6.94

11.52
18.56
29.50
50.27
64.67
85.56
118.01

8.35
13.54
21.31
35.59
45.19
59.37
80.79

0.55
0.89
1.41
2.40
3.09
4.09
5.64

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

15.62
25.34
40.44
68.39
87.92
116.94
161.56

9.76
15.87
25.18
42.21
53.90
71.39
97.97

0.62
1.01
1.61
2.72
3.50
4.66
6.43

13.20
21.20
33.67
57.53
74.03
97.78
134.80

8.76
14.14
22.27
37.53
47.83
62.85
85.84

0.53
0.84
1.34
2.29
2.95
3.89
5.37

11.13
17.88
27.97
47.28
60.57
79.45
109.39

8.12
13.13
20.38
33.86
42.82
55.87
75.98

0.44
0.71
1.11
1.88
2.41
3.16
4.36

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

14.88
24.02
37.84
64.80
83.42
110.04
151.65

9.34
15.12
23.71
40.20
51.39
67.55
92.51

0.51
0.82
1.29
2.21
2.85
3.76
5.18

12.89
20.70
32.37
54.73
70.00
91.80
126.39

8.58
13.83
21.53
35.94
45.55
59.51
81.16

0.44
0.71
1.10
1.87
2.39
3.13
4.31

10.93
17.46
27.20
46.20
58.81
76.36
103.75

8.00
12.87
19.92
33.22
41.83
54.08
72.75

0.37
0.60
0.93
1.58
2.01
2.61
3.54

NOTE:
1. Capacities are based on nominal airflow.
2. For any other conditions, please use selection software for fan coil units.
Apart from capacities, this software provides;
a) Sensible heat ratio
b) Leaving air temperature (DB/WB) - 0C
c) Leaving water temperature - 0C
d) Water pressure drop (feet of water)

LEGEND:

0
4 C EWT

0
7 C EWT

LPS - Water flow (Liters Per Second)

0
10 C EWT

TC

SC

LPS

TC

SC

LPS

TC

SC

LPS

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

10.25
15.75
25.01
50.51
67.38
86.76
113.06

6.59
10.13
16.02
31.57
41.73
53.59
69.93

0.55
0.85
1.35
2.71
3.62
4.66
5.13

8.70
13.09
21.0
41.93
55.93
71.74
98.10

6.03
9.08
14.44
27.96
36.90
47.14
64.13

0.47
0.71
1.13
2.27
3.02
3.91
5.10

6.88
10.19
16.43
33.76
44.80
56.93
78.71

5.39
8.02
12.80
25.07
32.80
41.58
57.01

0.38
0.55
0.89
1.83
2.43
3.09
4.22

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

9.63
14.41
23.22
46.73
62.37
79.77
110.51

6.21
9.34
14.93
29.40
38.95
49.66
68.46

0.42
0.62
1.01
2.02
2.70
3.47
4.76

7.73
11.54
18.24
38.77
52.15
65.30
90.22

5.42
8.11
12.74
26.09
34.70
43.43
59.62

0.33
0.50
0.79
1.68
2.26
2.84
3.87

5.86
8.43
13.29
30.40
40.88
51.01
71.80

4.69
6.76
10.66
22.99
30.40
37.95
52.86

0.26
0.37
0.57
1.32
1.76
2.21
3.09

BWY03
BWY05
BWY07
BWY10
BWY14
BWY18
BWY25

8.70
12.83
20.32
43.69
58.59
73.50
103.48

5.67
8.37
13.21
27.67
35.93
45.21
64.51

0.32
0.46
0.73
1.58
2.11
2.65
3.72

6.79
9.49
15.26
35.14
47.50
59.44
83.78

4.83
6.76
10.83
23.95
31.95
39.97
55.90

0.25
0.34
0.55
1.26
1.70
2.14
3.01

5.71
6.38
7.50
26.33
36.43
45.27
63.78

4.57
5.30
6.35
20.35
27.61
34.35
47.88

0.25
0.25
0.30
0.95
1.31
1.64
2.30

- Sensible Heat Capacity (kW)

EWT - Entering Water Temperature (0C)

ENTERING AIR TEMP. = 270C DB/19.50C WB


UNIT
SIZE

- Total Capacity (kW)

SC

WTR - Water Temperature Rise (0C)

SPLIT COIL*
WTR
0
C

TC

2 Row coil for BWY03, BWY05 & BWY07. 3 Row coil for BWY10 & above.

FAN PERFORMANCE DATA


DIRECT DRIVE MOTORS
MODEL No.: BWY03
BLOWER MOTOR HP

CFM @ External Static Pressure (inch wg.)

BLOWER MOTOR

0.5

0.75

SPEED

0.1

0.2

0.3

0.4

0.5

0.6

HIGH

1350

1290

1220

1160

1070

990
900

MEDIUM

1260

1200

1125

1060

1000

LOW

1070

1020

960

900

830

740

HIGH
MEDIUM

1660
1570

1480
1375

1300
1180

1230
1120

1140
1060

1060
960

LOW

1500

1320

1130

940

870

780

MODEL No.: BWY05


BLOWER MOTOR HP

CFM @ External Static Pressure (inch wg.)

BLOWER MOTOR

0.75

1.0

SPEED

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

HIGH

2010

1920

1820

1730

1620

1490

1350

1230

MEDIUM

1830

1740

1660

1570

1470

1360

1240

1100

LOW

1710

1650

1570

1490

1390

1300

1170

975

HIGH

2252

2215

2180

2140

2105

2065

2020

1950

MEDIUM

2021

1990

1950

1920

1880

1840

1795

1700

LOW

1820

1805

1790

1735

1700

1665

1630

1530

NOTE: Values include losses for dry coil, filter & unit casing.

BELT DRIVEN MOTORS


MODEL No.: BWY07
Airflow,
CFM (L/S)

0.2

0.4

External Static Pressure (inch wg.)


0.8
1.0

0.6

RPM

BHP

RPM

1800 (849)

820*

0.62*

900

2000 (944)

824*

0.7*

905

2200 (1038)

853

0.81

2400 (1133)

950

2600 (1227)

968

2800 (1321)

1054

1.4

1106

1.5

1160

1.61

3000 (1416)

1066

1.55

1133

1.7

1180

1.82

3200 (1510)

1091

1.75

1157

1.91

1202

2.02

1255

3400 (1605)

1116

1.96

1171

2.1

1228

2.3

1276

1.2

1.4

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

0.71

965

0.82

1020

0.88

1102

1.03

1145

1.14

1220

1.26

0.79

970

0.91

1026

1.0

1107

1.12

1152

1.25

1225

1.35

927

0.91

986

1.02

1041

1.13

1111

1.25

1160

1.36

1237

1.48

0.94

1004

1.05

1059

1.21

1132

1.27

1155

1.38

1244

1.5

1297

1.65

1.1

1032

1.22

1086

1.33

1150

1.45

1194

1.57

1250

1.69

1305

1.82

1216

1.76

1261

1.88

1323

2.02

1380*

2.2*

1234

1.94

1276

2.09

1334*

2.23*

1400*

2.3*

2.2

1307

2.33

1359*

2.47*

2.45

1329

2.6

1368*

2.73*

II

* For bold figures, consult your nearest Zamil representative for proper selection of drives. Drives shall be field supplied & installed.

MODEL No.: BWY10


Airflow,
CFM (L/S)

0.2
RPM BHP

0.4
RPM BHP

0.6
RPM BHP

2800 (1321)
3000 (1416)
3200 (1510)
3400 (1605)
3600 (1699)
3800 (1793)
4000 (1888)
4200 (1982)
4400 (2076)
4600 (2170)

610
625
636
660
675
700
727
772
791
840

0.62
0.69
0.77
0.88
1.0
1.13
1.28
1.41
1.58
1.79

710
720
734
746
760
778
790
843
864
890

0.75
0.80
0.92
1.01
1.16
1.3
1.45
1.62
1.79
1.96

745
760
780
805
820
840
865
880
887
931

4800 (2265)

857

1.95

906

2.17

947

2.4

5000 (2360)

876

2.15

920

2.38

961

2.6

0.87
0.95
1.06
1.18
1.32
1.43
1.62
1.78
1.94
2.2

0.8
RPM BHP
760
810
820
833
848
868
882
921
934
975

External Static Pressure (inch wg.)


1.0
1.2
1.4
RPM BHP RPM BHP RPM BHP

0.95
1.12
1.26
1.34
1.48
1.63
1.8
1.96
2.14
2.38

850
865
870
881
900
913
926
968
979
1017

1.2
1.25
1.38
1.5
1.66
1.8
1.96
2.16
2.34
2.59

988

2.57

1035

2.76

1005

2.76

905
915
925
939
950
966
980
1011
1024
1058

1.32
1.4
1.51
1.67
1.82
2.0
2.18
2.36
2.54
2.77

NOTES (For BWY07/BWY10): 1. Values include losses for filters, unit casing and wet coils.
2. 2 HP motor and alternative drive I to be used for the unshaded portion.
3. 3 HP motor and alternative drive II to be used for the shaded portion.

965
970
978
983
995
1006
1023
1054
1067

1.5
1.6
1.73
1.84
1.98
2.18
2.4
2.56
2.77

1.6
1.8
RPM BHP RPM BHP

2.0
RPM BHP

1000
1013
1023
1033
1043
1056
1066
1096

1100
1115
1122
1128
1131
1143

1.6
1.75
1.86
2.02
2.21
2.39
2.6
2.76

1054
1065
1073
1083
1090
1100
1108

1.8
2.0
2.1
2.25
2.41
2.58
2.77

II

2.0
2.15
2.28
2.44
2.6
2.78

FAN PERFORMANCE DATA (BELT DRIVEN MOTORS)


MODEL No.: BWY14
Airflow,
CFM (L/S)
4000 (1888)
4200 (1982)
4400 (2076)
4600 (2170)
4800 (2265)
5000 (2360)
5200 (2454)
5400 (2548)
5600 (2643)
5800 (2737)
6000 (2832)
6200 (2926)
6400 (3020)
6600 (3115)

0.2
RPM
694*
705*
719*
735*
748*
761*
778
800
808
826
837
850
879
894

BHP
1.21*
1.33*
1.43*
1.57*
1.72*
1.87*
2.06
2.31
2.46
2.68
2.90
3.12
3.41
3.76

0.4
RPM
743*
761*
774
787
800
812
823
846
858
869
885
900
920
933

0.6

BHP
1.3*
1.45*
1.6
1.75
1.92
2.09
2.27
2.5
2.7
2.9
3.12
3.41
3.70
4.0

RPM
797
811
823
835
846
862
873
894
903
917
927
940
962
973

0.8
BHP
1.52
1.67
1.8
1.95
2.09
2.30
2.48
2.72
2.90
3.12
3.37
3.65
3.96
4.24

RPM
845
857
869
885
897
904
917
934
945
955
965
980
1000
1013

External Static Pressure (inch wg.)


1.0
1.2
1.4
BHP
1.66
1.81
1.97
2.17
2.35
2.52
2.70
2.94
3.12
3.4
3.64
3.92
4.2
4.44

RPM
890
903
918
929
935
948
959
979
987
1000
1009
1021
1040
1050

BHP
1.83
2.0
2.17
2.34
2.52
2.70
2.91
3.15
3.38
3.65
3.9
4.17
4.45
4.68

RPM
937
951
963
971
979
989
1001
1019
1028
1041
1047
1061
1078
1091

BHP
2.03
2.19
2.33
2.55
2.72
2.91
3.11
3.38
3.65
3.9
4.13
4.38
4.69
4.92

RPM
975
992
1006
1013
1023
1032
1038
1056
1063
1078
1088
1100
1114
1125

1.6
BHP
2.25
2.43
2.58
2.75
2.91
3.11
3.34
3.64
3.83
4.13
4.35
4.66
4.92
5.2

RPM
992
1002
1010
1053
1065
1068
1070
1098
1106
1114
1123
1133
1150
1161

1.8
BHP
2.4
2.6
2.78
2.93
3.14
3.37
3.59
3.88
4.14
4.37
4.59
4.85
5.2
5.51

RPM
1075
1080
1093
1100
1107
1113
1119
1133
1139
1150
1157
1167
1183
1194

2.0
BHP
2.64
2.82
2.97
3.17
3.4
3.6
3.85
4.10
4.35
4.6
4.85
5.1
5.45
5.8

RPM
1102
1110
1133
1138
1144
1150
1159
1171
1176
1186
1194
1205
1218
1229

II

BHP
2.85
3.05
3.2
3.41
3.62
3.86
4.08
4.36
4.57
4.78
5.05
5.4
5.76
6.08

MODEL No.: BWY18


Airflow,
CFM (L/S)

0.2
RPM BHP

0.4
RPM BHP

0.6
RPM BHP

5000 (2360)
5200 (2454)
5400 (2548)
5600 (2643)
5800 (2737)
6000 (2832)
6200 (2926)
6400 (3020)
6600 (3115)
6800 (3209)
7000 (3303)
7200 (3398)
7400 (3492)
7600 (3587)
7800 (3681)
8000 (3775)
8200 (3870)
8400 (3964)

715*
718*
721*
725*
729*
733*
738*
745*
753*
761*
772*
777*
794*
805
820
830
867
890

731*
737*
750*
756*
762*
775*
788*
795*
800*
810
820
830
845
850
870
880
890
904

787*
793*
802*
807
816
833
839
850
855
863
875
880
890
900
909
922
936
945

1.33*
1.42*
1.53*
1.68*
1.81*
1.9*
2.03*
2.15*
2.38*
2.5*
2.69*
2.84*
2.96*
3.18
3.36
3.59
3.77
4.05

1.56*
1.68*
1.81*
1.92*
2.03*
2.14*
2.35*
2.5*
2.64*
2.78
2.92
3.08
3.3
3.5
3.69
3.86
4.1
4.42

1.82*
1.96*
2.07*
2.21
2.35
2.42
2.57
2.71
2.92
3.08
3.33
3.41
3.62
3.83
4.1
4.25
4.5
4.75

External Static Pressure (inch wg.)


0.8
1.0
1.2
1.4
RPM BHP RPM BHP RPM BHP RPM BHP
850
856
860
866
872
877
888
900
905
910
918
927
936
941
954
963
972
986

2.07
2.26
2.35
2.5
2.64
2.78
2.92
3.08
3.25
3.41
3.58
3.75
3.95
4.2
4.5
4.65
4.9
5.1

902
905
911
916
921
930
935
940
950
960
967
976
985
990
1002
1008
1016
1025

2.4
2.53
2.66
2.79
2.9
3.02
3.24
3.41
3.58
3.75
3.95
4.14
4.4
4.57
4.9
5.05
5.25
5.45

955
961
966
968
970
980
985
990
1000
1004
1012
1017
1021
1026
1041
1046
1054
1066

2.66
2.83
2.96
3.07
3.23
3.4
3.56
3.72
3.88
4.14
4.28
4.47
4.68
4.85
5.14
5.33
5.56
5.85

1005
1010
1012
1015
1020
1025
1030
1036
1045
1050
1054
1059
1065
1069
1083
1087
1100
1107

2.96
3.15
3.23
3.38
3.53
3.69
3.84
4.04
4.23
4.47
4.66
4.85
5.09
5.23
5.47
5.75
6
6.24

1.6
RPM BHP

1.8
2.0
RPM BHP RPM BHP

1057
1060
1062
1065
1066
1070
1080
1082
1083
1090
1095
1100
1108
1112
1125
1128
1132
1140

1104
1107
1109
1110
1113
1118
1120
1126
1127
1134
1135
1141*
1150*
1154*
1158*
1164*
1172*

3.3
3.46
3.57
3.73
3.84
4.0
4.27
4.45
4.6
4.83
5.04
5.19
5.47
5.66
5.9
6.12
6.36
6.72

II

3.6
3.76
3.88
4.07
4.18
4.4
4.63
4.82
5
5.16
5.39
5.58*
5.8*
6*
6.36*
6.6*
6.84*

1153*
1155*
1157*
1158*
1159*
1162*
1163*
1165*
1170*
1175*
1179*
1183*
1185*
1193*
1200*

3.88*
4.04*
4.27*
4.4*
4.59*
4.72*
4.95*
5.09*
5.3*
5.51*
5.72*
5.95*
6.12*
6.42*
6.78*

NOTES (For BWY14/BWY18): 1. Values include losses for filters, unit casing and wet coils.
2. Standard 5 HP motor and Alt. I drive to be used for the unshaded portion.
3. Alt. 7.5 HP motor and Alt. II drive to be used for the shaded portion.
* For bold figures, consult your nearest Zamil representative for proper selection of drives. Drives shall be field supplied & installed.

MODEL No.: BWY25


Airflow,
CFM (L/S)

0.4
RPM BHP

0.6
RPM

0.8
RPM BHP

BHP

External Static Pressure (inch wg.)


1.0
1.2
1.4
RPM BHP RPM BHP RPM BHP

1.6
RPM BHP

2.6*
762*
3.12*
812
3.6
857
4.0
900
4.5
944
5.0
980
6000 (2832) 700*
2.8*
764*
3.3*
813
3.78
858
4.22
901
4.73
945
5.23
981
6400 (3020) 706*
3.05*
766*
3.5*
814
4.0
859
4.42
902
4.96
946
5.45
982
6800 (3209) 716*
3.24*
768*
3.7*
815
4.19
860
4.64
903
5.2
946
5.68
983
7200 (3398) 722*
3.4*
770*
3.82*
816
4.35
861
4.88
904
5.45
947
5.9
985
7600 (3587) 732*
3.6*
772*
4.0*
818
4.56
861
5.18
904
5.65
947
6.12
986
8000 (3775) 740*
3.9*
778*
4.35*
819
4.85
865
5.5
906
5.97
949
6.48
988
8400 (3964) 751*
4.2*
800
4.65
821
5.16
869
5.81
908
6.3
951
6.8
990
8800 (4152) 790*
800
4.5
810
5.0
823
5.5
873
6.14
911
6.75
953
7.15
992
9200 (4341)
805
4.9
820
5.35
825
5.84
877
6.45
915
7.1
955
7.6
994
9600 (4530)
5.2
825
5.67
826
6.15
882
6.7
920
7.4
957
8.06
996
10000 (4719) 815
5.55
830
6.1
838
6.6
890
7.1
928
7.85
965
8.4
1003
10400 (4907) 825
5.9
840
6.5
870
7.0
898
7.5
936
8.3
973
8.8
1009
10800 (5096) 835
6.4
856
6.9
876
7.4
906
7.95
944
8.7
981
9.25
1014
11200 (5286) 840
6.8
872
7.3
885
7.9
914
8.45
952
9.15
989
9.6
11600 (5474) 852
12000 (5663) 870
7.2
885
7.8
892
8.5
925
9.0
961
9.6
996
10.1
* For bold figures, consult your nearest Zamil representative for proper selection of drives. Drives shall be field supplied & installed.
Notes: 1. Values include losses for filters, unit casing and wet coils.
2. Standard 7.5 HP motor to be used for the unshaded portion.
3. Alt. 10 HP motor to be used for the shaded portion.

10

5.46
5.71
5.97
6.23
6.5
6.8
7.2
7.6
8.0
8.35
8.71
9.1
9.5
9.9
-

1.8
RPM BHP

2.0
RPM BHP

1015
1017
1017
1018
1018
1019
1020
1020
1022
1023
1023
1034*
-

1059*
1059*
1059*
1060*
1060*
1061*
1062*
1062*
1064*
1065*
1067*
-

6.0
6.3
6.6
6.95
7.25
7.5
7.8
8.1
8.45
8.75
9.25
9.7*
-

II

6.6*
6.92*
7.22*
7.51*
7.78*
8.05*
8.35*
8.65*
9.0*
9.45*
9.8*
-

ELECTRICAL DATA
MODEL No.: BWY03
POWER
SUPPLY
(V-Ph-Hz)

VOLTAGE
RANGE
MIN.

208/230-1-60

187

MAX.

BLOWER

**

HP

FLA

0.50
(STD.)

1.8

253

0.50
(STD.)
187

0.50
(STD.)
342

0.50
(STD.)
414

4.7

1.8

418
0.75
(ALT.)

460-3-60

1.8

253
0.75
(ALT.)

380-3-60
(4 WIRE)

4.7

4.7

1.0

506
0.75
(ALT.)

2.6

POWER
SUPPLY
(V-Ph-Hz)

ELECTRIC HEATER

MOTOR

0.75
(ALT.)

208/230-3-60

MODEL No.: BWY07


MCA
kW

FLA

5
6/7
10*/12*
14*

5
6/7
10*/12*
14*

5
6/7.5
10*/12*
15*

5
6/7.5
10*/12*
15*

5
6/7.5
10*/12*
15*

5
6/7.5
10*/12*
15*

5
6/7.5
10*/12*
15*

5
6/7.5
10*/12*
15*

21.7
26.1/30.4
43.5/52.2
60.9

21.7
26.1/30.4
43.5/52.2
60.9

12.6
15.1/18.8
25.1/30.1
37.7

12.6
15.1/18.8
25.1/30.1
37.7

7.6
9.1/11.4
15.2/18.2
22.8

7.6
9.1/11.4
15.2/18.2
22.8

6.3
7.5/9.4
12.6/15.1
18.8

6.3
7.5/9.4
12.6/15.1
18.8

MOCP

MIN.
2.3
29.4
34.9/40.3
56.6/67.5
78.4
5.9
33
38.5/43.9
60.3/71.1
82
2.3
18
21.1/25.8
33.6/39.9
49.4
5.9
21.6
24.8/29.4
37.3/43.5
53
2.3
11.8
13.6/16.5
21.3/25
30.8
5.9
15.4
17.3/20.1
24.9/28.6
34.4
1.3
9.1
10.6/13
17/20.1
24.8
3.3
11.1
12.6/15
19/22.1
26.8

15
30
40/45
60/70
80
15
35
40/45
70/80
90
15
20
25/30
35/40
50
15
25
30/35
40/45
60
15
15
15/20
25/30
35
15
20
20/25
30/30
35
15
15
15/20
20/25
30
15
15
15/20
20/25
30

VOLTAGE
RANGE
MIN.

208/230-1-60

208/230-3-60

380-3-60
(4 WIRE)

460-3-60

187

187

342

414

MAX.

BLOWER

**

208/230-3-60

FLA

0.75
(STD.)

4.7

1.0
(ALT.)

8.2

253

0.75
(STD.)

4.7

1.0
(ALT.)

8.2

0.75
(STD.)

4.7

1.0
(ALT.)

8.2

0.75
(STD.)

3.0

1.0
(ALT.)

4.4

253

418

506

187

kW

FLA

5
6/7
10*/12*
14*

5
6/7
10*/12*
14*

5
6/7.5
10*/12*
15*

5
6/7.5
10*/12*
15*

5
6/7.5
10*/12*
15*

5
6/7.5
10*/12*
15*

5
6/7.5
10*/12*
15*

5
6/7.5
10*/12*
15*

21.7
26.1/30.4
43.5/52.2
60.9

21.7
26.1/30.4
43.5/52.2
60.9

12.6
15.1/18.8
25.1/30.1
37.7

12.6
15.1/18.8
25.1/30.1
37.7

7.6
9.1/11.4
15.2/18.2
22.8

7.6
9.1/11.4
15.2/18.2
22.8

6.3
7.5/9.4
12.6/15.1
18.8

6.3
7.5/9.4
12.6/15.1
18.8

5.9
33
38.5/43.9
60.3/71.1
82
10.3
37.4
42.9/48.3
64.6/75.5
86.4
5.9
21.6
24.8/29.4
37.3/43.5
53
10.3
26
29.1/33.8
41.6/47.9
57.4
5.9
15.4
17.3/20.1
24.9/28.6
34.3
10.3
19.8
21.6/24.5
29.3/33
38.8
3.8
11.6
13.1/15.5
19.5/22.6
27.3
5.5
13.4
14.9/17.3
21.3/24.4
29

FLA

2
(STD.)

380-3-60
(4 WIRE)

342

6.6

253
8.8

418
3
5.14
(ALT.)

2
(STD.)

414

3
(ALT.)

MOCP
15
40
45/50
70/80
90
15
40
45/50
70/80
90
15
25
25/30
40/45
60
15
30
30/35
45/50
60
15
20
20/25
25/30
35
15
25
25/30
30/35
40
15
15
15/20
20/25
30
15
15
20/20
25/25
30

3.5

506

ELECTRIC HEATER
MCA

HP

3
(ALT.)

460-3-60

MOTOR
HP

MAX.

BLOWER
MOTOR

2
(STD.)

MODEL No.: BWY05


POWER
SUPPLY
(V-Ph-Hz)

VOLTAGE
RANGE

4.1

ELECTRIC HEATER
MCA
kW

Full Load Amps

HP

Horse Power

MCA

Minimum Circuit Amps

11

8.3

15

12.6

24

25
30/35

6/7.5

15.1/18.8

27.1/31.8

25.1/30.1

39.6/45.9

40/50

15*/20*

37.7/50.2

55.4/71

60/80

25*/30*

62.8/75.3 86.8/102.4

90/110

11

20

12.6

26.8

30

6/7.5

15.1/18.8

29.9/34.5

35/35

10*/12*

25.1/30.1

42.4/48.6

45/50

15*/20*

37.7/50.2

58.1/73.8

60/80

25*/30*

62.8/75.3 89.5/105.1 90/110

15

7.6

14.5

15

6/7.5

9.1/11.4

16.4/19.3

20/20

10*/12*

15.2/18.2

24/27.8

25/30

15*/20*

22.8/30.4

33.5/43

35/45

25*/30*

38/45.6

52.5/62

60/70

6.4

15

7.6

15.9

20

6/7.5

9.1/11.4

17.8/20.7

20/25

10*/12*

15.2/18.2

25.4/29.2

30/30

15*/20*

22.8/30.4

34.9/44.4

40/45

25*/30*

38/45.6

53.9/63.4

60/70

4.4

15

6.3

12.3

15

6/7.5

7.5/9.4

13.8/16.1

15/20

10*/12*

12.6/15.1

20.1/23.3

25/25

15*/20*

18.8/25.1

27.9/35.8

30/40

25*/30*

31.4/37.7

43.6/51.5

45/60

5.1

15

6.3

13

15

6/7.5

7.5/9.4

14.5/16.9

15/20

10*/12*

12.6/15.1

20.9/24

25/25

15*/20*

18.8/25.1

28.6/36.5

30/40

25*/30*

31.4/37.7

44.4/52.3

45/60

MOCP Maximum Over Current Protection

* Combination of 2 heater modules


** Single phase motors

10*/12*

LEGEND:
FLA

MOCP

FLA

ELECTRICAL DATA
MODEL No.: BWY10
POWER
SUPPLY
(V-Ph-Hz)

VOLTAGE
RANGE
MIN.

MAX.

BLOWER
MOTOR
HP

FLA

2
(ALT.)

208/230-3-60

187

2
(ALT.)

342

8.8

2
(ALT.)

460-3-60

414

MCA
kW

3.5

4.1

FLA

Full Load Amps

HP

Horse Power

MCA

Minimum Circuit Amps

MAX.

BLOWER
MOTOR
HP

FLA

ELECTRIC HEATER
MCA
kW

MOCP

FLA

8.3

15

17.3

30

12.6

24

25

12.6

33

40
45/45

15.1/18.8

27.1/31.8

30/35

25.1/30.1

39.6/45.9

40/50

15*/20*

37.7/50.2

55.4/71

25*/30*

6/7.5

15.1/18.8

36.1/40.8

10*/12*

25.1/30.1

48.6/54.9

50/60

60/80

15*/20*

37.7/50.2

64.4/80

70/90

62.8/75.3 86.8/102.4 90/110

25*/30*

62.8/75.3 95.8/111.4 100/125

11

20

12.6

26.8

30

6/7.5

15.1/18.8

29.9/34.5

35/35

10*/12*

25.1/30.1

42.4/48.6

45/50

15*/20*

37.7/50.2

58.1/73.8

25*/30*

5
13.8
(STD.)

208/230-3-60

187

253

7.5
19.5
(ALT.)

24.4

40

12.6

40.1

50

6/7.5

15.1/18.8

43.3/47.9

50/60

10*/12*

25.1/30.1

55.8/62

60/70

60/80

15*/20*

37.7/50.2

71.5/87.1

80/90

62.8/75.3 89.5/105.1 90/110

25*/30*

62.8/75.3 102.9/118.5 110/125

15

11.3

20

7.6

14.5

15

7.6

20.8

25

6/7.5

9.1/11.4

16.4/19.3

20/20

10*/12*

15.2/18.2

24/27.8

25/30

15*/20*

22.8/30.4

33.5/43

25*/30*

38/45.6

52.5/62

6.4

15

7.6

15.9

20

6/7.5

9.1/11.4

22.6/25.5

25/30

10*/12*

15.2/18.2

30.3/34

35/35

35/45

15*/20*

22.8/30.4

39.8/49.3

45/50

60/70

25*/30*

38/45.6

58.8/68.3

60/70

6/7.5

9.1/11.4

17.8/20.7

20/25

10*/12*

15.2/18.2

25.4/29.2

30/30

15*/20*

22.8/30.4

34.9/44.4

25*/30*

38/45.6

53.9/63.4

5
(STD.)

380-3-60
(4 WIRE)

342

418

7.5
12.5
(ALT.)

15.6

25

7.6

25.1

35

6/7.5

9.1/11.4

27/29.9

35/35

10*/12*

15.2/18.2

34.6/38.4

40/45

40/45

15*/20*

22.8/30.4

44.1/53.6

50/60

60/70

25*/30*

38/45.6

63.1/72.6

70/80

4.4

15

8.6

15

6.3

12.3

15

6.3

16.5

20
20/25

6/7.5

7.5/9.4

13.8/16.1

15/20

10*/12*

12.6/15.1

20.1/23.3

25/25

15*/20*

18.8/25.1

27.9/35.8

25*/30*

31.4/37.7

6/7.5

7.5/9.4

18/20.4

10*/12*

12.6/15.1

24.4/27.5

30/30

30/40

15*/20*

18.8/25.1

32.1/40

35/45

43.6/51.5

45/60

25*/30*

31.4/37.7

47.9/55.8

50/60

5.1

15

6.3

13

15

6/7.5

7.5/9.4

14.5/16.9

15/20

10*/12*

12.6/15.1

20.9/24

25/25

15*/20*

18.8/25.1

28.6/36.5

25*/30*

31.4/37.7

44.4/52.3

5
(STD.)

460-3-60

414

6.9

506

7.5
9.75
(ALT.)

12.2

20

6.3

20.1

25

6/7.5

7.5/9.4

21.6/23.9

25/30

10*/12*

12.6/15.1

27.9/31.1

30/35

30/40

15*/20*

18.8/25.1

35.7/43.6

40/45

45/60

25*/30*

31.4/37.7

51.4/59.3

60/70

LEGEND:
FLA

VOLTAGE
RANGE
MIN.

6/7.5

506

3
(STD.)

MOCP

10*/12*

418

3
5.14
(STD.)

POWER
SUPPLY
(V-Ph-Hz)

ELECTRIC HEATER

253

3
(STD.)

380-3-60
(4 WIRE)

6.6

MODEL No.: BWY14

MOCP Maximum Over Current Protection

* Combination of 2 heater modules

12

ELECTRICAL DATA
MODEL No.: BWY18
POWER
SUPPLY
(V-Ph-Hz)

VOLTAGE
RANGE
MIN.

MAX.

BLOWER
MOTOR
HP

FLA

5
13.8
(STD.)

208/230-3-60

187

253

7.5
19.5
(ALT.)

5
(STD.)

380-3-60
(4 WIRE)

342

418

7.5
12.5
(ALT.)

5
(STD.)

460-3-60

414

6.9

506

7.5
9.75
(ALT.)

MODEL No.: BWY25


POWER
SUPPLY
(V-Ph-Hz)

ELECTRIC HEATER
MCA
kW

MOCP

MIN.

FLA

Full Load Amps

HP

Horse Power

MCA

Minimum Circuit Amps

MAX.

BLOWER
MOTOR
HP

FLA

ELECTRIC HEATER
MCA
kW

MOCP

FLA

17.3

30

25.5

45

12.6

33

40

12.6

41.2

50

6/7.5

15.1/18.8

36.1/40.8

45/45

10*/12*

25.1/30.1

48.6/54.9

50/60

15*/20*

37.7/50.2

64.4/80

70/90

25*/30*

62.8/75.3 95.8/111.4 100/125

35*/40*

87.9/100.4 127.1/142.8 150/150

24.4

40

12.6

40.1

50

6/7.5

15.1/18.8

43.3/47.9

50/60

10*/12*

25.1/30.1

55.8/62

60/70

15*/20*

37.7/50.2

71.5/87.1

80/90

25*/30*

62.8/75.3 102.9/118.5 110/125

35*/40*

87.9/100.4 134.3/149.9 150/175

7.5
20.4
(STD.)

208/230-3-60

187

253

10
26.1
(ALT.)

6/7.5

15.1/18.8

44.3/49

60/60

10*/12*

25.1/30.1

56.9/63.2

70/70

15*/20*

37.7/50.2

72.6/88.3

80/90

25*/30*

62.8/75.3 103.9/119.6 110/125

35*/40*

87.9/100.4 135.3/151 150/175

32.6

50

12.6

48.3

70

6/7.5

15.1/18.8

51.5/56.2

70/70

10*/12*

25.1/30.1

64/70.3

80/80

15*/20*

37.7/50.2

79.7/95.4

90/100

25*/30*

62.8/75.3 111.1/126.8 125/150

35*/40*

87.9/100.4 142.4/158.1 150/175

11.3

20

15.6

25

7.6

20.8

25

7.6

25.1

35

6/7.5

9.1/11.4

22.6/25.5

25/30

10*/12*

15.2/18.2

30.3/34

35/35

15*/20*

22.8/30.4

39.8/49.3

25*/30*

38/45.6

35*/40*

6/7.5

9.1/11.4

27/29.9

35/35

10*/12*

15.2/18.2

34.6/38.4

40/45

45/50

15*/20*

22.8/30.4

44.1/53.6

50/60

58.8/68.3

60/70

25*/30*

38/45.6

63.1/72.6

70/80

53.2/60.8

77.8/87.3

80/90

35*/40*

53.2/60.8

82.1/91.6

90/100

15.6

25

20

35

7.6

25.1

35

7.6

29.5

40

6/7.5

9.1/11.4

27/29.9

35/35

10*/12*

15.2/18.2

34.6/38.4

40/45

15*/20*

22.8/30.4

44.1/53.6

25*/30*

38/45.6

63.1/72.6

35*/40*

53.2/60.8

82.1/91.6

8.6

6.3

7.5
12.5
(STD.)

380-3-60
(4 WIRE)

342

418

6/7.5

9.1/11.4

31.4/34.2

45/45

10*/12*

15.2/18.2

39/42.8

50/50

50/60

15*/20*

22.8/30.4

48.5/58

50/60

70/80

25*/30*

38/45.6

67.5/77

70/80

90/100

35*/40*

53.2/60.8

86.5/96

90/100

15

12.8

20

16.5

20

6.3

20.6

25

6/7.5

7.5/9.4

18/20.4

20/25

10*/12*

12.6/15.1

24.4/27.5

30/30

15*/20*

18.8/25.1

32.1/40

25*/30*

31.4/37.7

35*/40*

10
(ALT.)

16

6/7.5

7.5/9.4

22.2/24.5

30/30

10*/12*

12.6/15.1

28.4/31.6

35/35

35/45

15*/20*

18.8/25.1

36.3/44.1

40/45

47.9/55.8

50/60

25*/30*

31.4/37.7

52/59.8

60/60

43.9/50.2

63.5/71.4

70/80

35*/40*

43.9/50.2

67.7/75.5

70/80

12.2

20

16.3

25

6.3

20.1

25

6.3

24.1

35

6/7.5

7.5/9.4

21.6/23.9

25/30

10*/12*

12.6/15.1

27.9/31.1

30/35

15*/20*

18.8/25.1

35.7/43.6

25*/30*

31.4/37.7

35*/40*

43.9/50.2

7.5
10.2
(STD.)

460-3-60

414

506

10
(ALT.)

6/7.5

7.5/9.4

25.7/28

35/35

10*/12*

12.6/15.1

31.9/35.1

40/40

40/45

15*/20*

18.8/25.1

39.8/47.6

45/50

51.4/59.3

60/70

25*/30*

31.4/37.7

55.5/63.3

60/70

67.1/74.9

70/80

35*/40*

43.9/50.2

71.2/79

80/80

LEGEND:
FLA

VOLTAGE
RANGE

MOCP Maximum Over Current Protection

* Combination of 2 heater modules

13

13

DIMENSIONS
BWY03 - BWY14 (HORIZONTAL DISCHARGE)

NOTE: 1. All dimensions are in mm (dimensions in brackets are in inches).


2. Hot water coil connection is available only if hot water coils are ordered.
DIMENSIONS
MODEL
BWY03

A
1092(43)

648(25.5) 575(22.64) 483(19.02) 143(5.63) 406(15.98)

542(21.34) 524(20.63) 297(11.69) 553(21.77) 171(6.73)

178(7.01)

140(5.51)

19(0.75)

19(0.75)
25(1)

45(1.77)

707(27.83) 550(21.65) 297(11.69) 553(21.77) 171(6.73)

178(7.01)

140(5.51)

25(1)

813(32)

182(7.16) 406(15.98)

66(2.6)

995(39.17) 550(21.65) 378(14.88) 721(28.38) 164(6.46)

165(6.5)

132(5.2)

32(1.25)

25(1)

BWY10

1490(58.7) 1400(55.12) 675(26.57)

813(32)

332(13.1) 406(15.98)

42(1.65)

206(8.11)

140(5.51)

38(1.5)

32(1.25)

1321(52)

187(7.36) 406(15.98)

55(2.16) 1495(58.86) 655(25.8) 471(18.54) 791(31.14)

152(5.98)

140(5.51)

38(1.5)

32(1.25)

1625(64)

1600(63)

600(23.62) 483(19.02) 224(8.82) 406(15.98)

45(1.77)

1360(53.5) 1100(43.31) 600(23.62)

BWY14

813(32)

BWY07

BWY05

1092(43)

705(27.75)

1295(51)

625(24.61) 378(14.88) 721(28.38) 112(4.41)

14

127(5)

DIMENSIONS
BWY03 - BWY14 (VERTICAL DISCHARGE)

NOTE: 1. All dimensions are in mm (dimensions in brackets are in inches).


2. Hot water coil connection is available only if hot water coils are ordered.
DIMENSIONS
MODEL
BWY03
BWY05

A
1092(43)
1092(43)

813(32)

600(23.62) 483(19.02) 229(9.02) 406(15.98)

1360(53.5) 1100(43.31) 600(23.62)

813(32)

BWY10

1490(58.7) 1400(55.12) 675(26.57)

813(32)
1321(52)

1625(64)

648(25.5) 575(22.64) 483(19.02) 134(5.28) 406(15.98)

BWY07
BWY14

1600(63)

705(27.75)

35(1.38)

543(21.38) 502(19.76) 285(11.22) 553(21.77) 171(6.73)

178(7.01)

140(5.51)

19(0.75)

19(0.75)

32(1.26)

712(28.03) 502(19.76) 300(11.81) 553(21.77) 171(6.73)

25(1)

178(7.01)

140(5.51)

25(1)

504(19.83) 302(11.87) 697(27.53) 164(6.46)

165(6.5)

132(5.2)

32(1.25)

25(1)

365(14.38) 406(15.98)

35(1.38) 1299(51.15) 607(23.91) 338(13.29) 732(28.81) 101(3.98)

194(7.64)

159(6.26)

38(1.5)

32(1.25)

224(8.82) 406(15.98)

49(1.92) 1497(58.95) 607(23.91) 370(14.59) 929(36.56)

152(5.98)

140(5.51)

38(1.5)

32(1.25)

213(8.4)

406(15.98)

85(3.34)

991(39)

15

127(5)

DIMENSIONS
BWY18 - BWY25 (HORIZONTAL DISCHARGE)

NOTE: 1. All dimensions are in mm (dimensions in brackets are in inches).


2. Hot water coil connection is available only if hot water coils are ordered.
DIMENSIONS
MODEL
BWY18
BWY25

A
1625(64)

2070(81.5) 705(27.75)

1825(71.85) 2362(93)

840(33.1)

1575(62)

382(15.04) 483(19.02)

35(1.38)

1965(77.36) 655(25.79) 471(18.54) 791(31.14)

127(5)

152(5.98)

140(5.51)

38(1.5)

32(1.25)

1575(62)

590(23.23) 483(19.02)

50(1.97)

2257(88.86) 790(31.1)

127(5)

152(5.98)

140(5.51)

38(1.5)

32(1.25)

16

K
503(19.8)

L
913(35.94)

DIMENSIONS
BWY18 - BWY25 (VERTICAL DISCHARGE)

NOTE: 1. All dimensions are in mm (dimensions in brackets are in inches).


2. Hot water coil connection is available only if hot water coils are ordered.
DIMENSIONS
MODEL
BWY18
BWY25

A
1625(64)

2070(81.5) 705(27.75)

1825(71.85) 2362(93)

840(33.1)

1575(62)

422(16.61) 483(19.02)

46(1.81)

1969(77.52) 596(23.46) 354(13.94) 878(34.57)

127(5)

152(5.98)

140(5.51)

38(1.5)

32(1.25)

1575(62)

625(24.61) 483(19.02)

74(2.91)

2217(87.28) 596(23.46) 704(27.72) 878(34.57)

127(5)

152(5.98)

140(5.51)

38(1.5)

32(1.25)

17

DIMENSIONS - HEATER BOX


BWY03 - BWY05
415

(16

.3")

205 (8.1")

(1")
25.4 YP
T

490

(19.3
")

HEATER CONTROLS MTG


PLATE

HEATER CONTROLS MTG


COVER

BWY07 - BWY14
412

.2")
(16

P
) TY
(1 "

205 (8.1")

4
25.

DIMENSIONS
MODEL

HEATER ACCESS COVER

BWY07

818 (32.2)

BWY10

818 (32.2)

BWY14

1326(52.2)

HEATER CONTROLS MTG


PLATE

HEATER CONTROLS MTG


COVER

BWY18 - BWY25
.4")
(19
492

T
1")

YP

205 (8.1")

(
25.4

1581 (6
2.3")

HEATER ACCESS COVER


(BOTH SIDES)

HEATER CONTROLS MTG


COVER
HEATER CONTROLS MTG
PLATE

NOTES:

1. All dimensions are in mm (dimensions in brackets are in inches).


2. Heater box is an optional feature.

18

TYPICAL SCHEMATIC WIRING DIAGRAM


REFER TO UNIT
NAMEPLATE FOR
POWER SUPPLY

LEGEND
AFS
ATB
AR
BM
BMC
ECB
FL
HC
HVTB
HTR
L1
L2
L3
LVTB
LUG
MOHT
N
NTB
OHT
OLR
VFC

N (SEE NOTE -8)

___
+

AIRFLOW SWITCH
AUXILIARY TERMINAL BLOCK
AUXILIARY RELAY
BLOWER MOTOR
BLOWER MOTOR CONTACTOR
ELECTRONIC CONTROL BOARD
FUSE LINK
HEATER CONTACTOR
HIGH VOLTAGE TERMINAL BLOCK
HEATER
LINE 1
LINE 2
LINE 3
LOW VOLTAGE TERMINAL BLOCK
LUG GROUND
MANUAL RESET OHT
NEUTRAL
NEUTRAL TERMINAL BLOCK
OVERHEAT THERMOSTAT
OVER LOAD RELAY
VOLT FREE CONTACT
FIELD WIRING
DISCONNECT TAB - 1/4"

NOTES
1. POWER SUPPLY, REFER TO UNIT NAMEPLATE.
THERMOSTAT CONTROL VOLTAGE - 24VAC.
2. ANY WIRE REPLACEMENT SHOULD BE OF THE 900C
OR ITS EQUIVALENT.
USE COPPER CONDUCTOR WIRES ONLY.
VFC OPTION FOR BM ON,OFF &TRIP INDICATION
WITH FURNAS/SIEMENS CONTACTOR AND OLR

3. A 3 TO 4 MINUTE (APPROX.) BUILT-IN SHORT CYCLE


PROTECTION FOR COMPRESSOR IS AVAILABLE IN
ZAMIL ELECTRONIC THERMOSTAT.
4. IF HEATERS ARE FACTORY INSTALLED, PLEASE
READ BROKEN LINES AS CONTINUOUS LINES.
5. FUSED DISCONNECT SWITCH OR CIRCUIT BREAKER
TO BE PROVIDED BY CONSUMER WITH RATING AS
RECOMMENDED BY MANUFACTURER.
6. HVTB IS REQUIRED ONLY FOR HEATER MODELS.
7. BMC-OLR CONNECTING WIRE NOT REQUIRED FOR
OLR. FIXED DIRECTLY BENEATH CONTACTOR.
8. NEUTRAL LINE REQUIRED ON 380V-3Ph-60Hz POWER
SUPPLY ONLY.

19

CONTROLS & SEQUENCE OF OPERATION


The operation of the air conditioning unit is controlled by a 24VAC electronic control board. All the contactors are operated by the 24V circuit, including the thermostat.

Mode:
Select the desired mode of operation by continuous pressing of the MODE button:

24 V
(C)

Controls cooling system only (the word COOL will


display for 5 seconds).

Controls heating system only (the word HEAT will


display for 5 seconds).

Y2
L
I
G
H
T
S

HEAT/COOL - Controls both systems automatically (the word AUTO will display for 5 seconds).
OFF -

24VAC

24 V

Systems will not operate.

Y1
G
W1
W2

Equipment
Relays

Fan Relay
1st stage
Heating
2nd stage
Heating

Cooling:
Select the temperature you want your cooling system to
maintain by pressing and holding the COOLING button
under the
or
symbols until the desired temperature
is displayed. The control setpoint temperature is displayed
for 5 seconds.

LED 1
LED 2
Thermostat
Field Wiring

Line Voltage
Transformer

2nd stage
Cooling
1st stage
Cooling

Clogged Filter

Compressor Fault

* Clogged filter switch not provided

Heating:
Select the temperature you want your heating system to maintain by pressing and holding the HEATING button under
the
or
symbols until the desired temperature is displayed. The control setpoint temperature is displayed for 5
seconds.

Fan:
The fan will be energized automatically when the systems are operating but no indication of this on the display. To select
continuous fan operation, press the FAN button and the display will show
. This is recommended for electronic air
cleaners and continuous ventilation requirements.

Off
When the word OFF is displayed the heating and cooling systems will not operate. Avoid using the OFF mode during
extremely cold weather to prevent damage from freezing.

Auto:
Selecting this mode of operation will control both heating and cooling systems. The thermostat will automatically switch
from one to the other as determined by the selected temperatures in heating and cooling.
NOTE: The thermostat always maintains a minimum 20F (10C) difference or dead band between the heating and cooling
setpoints.

Celsius/Fahrenheit
Simultaneously press

and

to switch between Celsius and Fahrenheit temperature display.

20

INSTALLATION INSTRUCTIONS
A. GENERAL
Blower units are shipped completely wired. Only external power, control wiring & piping connections are needed to
complete the installation.

B. UNIT LOCATION & ACCESS SPACE


The placement of the unit in relationship to the building is very important. A minimum of 36 inches clearance must be kept
on the service access side and return air side.
When making piping connections, be sure to provide clearance for electrical connections.

C. TUBING INSTALLATION
Do not remove plugs from the pipe stub out until tubing has been run and is ready for connection.
a. Make sure the tubing is round, without dent or burrs.
b. Cut tubing to the length required.
NOTE: When installing piping through walls or along side of any structural members, be sure the piping is isolated from
these members or walls to avoid any transmission of vibration that may occur, while unit is running.

ELECTRICAL
STEP 1: INSTALLATION
A) Please ensure power supply to the unit is as per unit nameplate (Volts/Ph/Hz) requirements.
Caution: Operation of the unit on improper power supply will result in damage to the unit.
NOTE: Use copper wires of proper rating for all field wiring.
Warning: Before servicing or installation of the unit, always TURN OFF all power to the unit. There may be more than
one disconnect switch. Ensure all of them are turned off. Electrical shock can cause personal injury or death.
B) Ground & power wires
Connect power wires to terminal block per wiring diagram.
Connect ground wire to the ground lug inside the control box.
C) Control wiring
Use 16 gauge color-coded wire for control wiring.

STEP 2: SEQUENCE OF OPERATION


With power supplied to indoor unit, the unit starts responding to the thermostat mode requirement.
Cooling mode: When thermostat calls for cooling, the blower motor in the indoor unit is switched on.
As the conditioned space approaches the thermostat cooling set point, the unit cycles off.
Heating mode: When thermostat calls for heating, the blower motor in the indoor unit is switched on. The contactor for
electric heater is switched on to energize the heaters. If the room temperature is not satisfied and there are two heaters
installed, the second heater also will be energized. Once, the conditioned space approaches the desired temperature set
point, the heating stages cycles off.
Fan mode: In this mode the indoor unit blower motor is switched on alone.

RECOMMENDED SPARE PARTS


PERCENTAGE OF SPARE PARTS
ITEM
EVAPORATOR BLOWER MOTOR

ONE YEAR SUPPLY

TWO YEAR SUPPLY

100 UNITS

1000 UNITS

100 UNITS

1000 UNITS

HEATER CONTACTOR

ELECTRIC HEATER

BLOWER WHEEL

THERMOSTAT

FILTER

NOTE : When ordering spare parts, please quote the complete model number on the unit nameplate.