Вы находитесь на странице: 1из 2

Rf.

IC 07/A
LD SC - 12-2012

Marine Diesel Generators


4 strokes Diesel engine, direct injection
Power definition
Standard ISO 3046/1 - 1995 (F)

Reference conditions
25 C / 77 F
100 kPa
30 %
25 C / 77 F

Ambiant tempeature
Barometric pressure
Relative humidity
Raw water temperature

Fuel oil
0,840 0,005
42 700 kJ/kg
5%
35 C / 95 F

Relative density
Lower calorific power
Consumption tolerances
Air inlet limit de temperature
Not contractual picture

Electrical power
Power in kVA declared at pf 0.8

GENERAL DATA
Models
4 W105S
6 W105S
6 W126S
6 M19.3
6 M26.2
8 M26.2
12 M26.2

Nb cyl

Arrangement

Bore (mm)

Stroke (mm)

Swept vol. (l)

Flywheel housing

4
6
6
6
6
8
12

in line
in line
in line
in line
in line
in V
in V

105
105
126
126
150
150
150

130
130
155
155
150
150
150

4.50
6.75
11.56
11.56
15.90
21.20
31.80

SAE 3
SAE 3
SAE 1
SAE 1
SMB
SAE 0
SAE 0

MAXIMUM RATING TABLE


COP

4 W105S
6 W105S
6 W126S
6 M19.3
6 M26.2
8 M26.2
12 M26.2

50 Hz

kWe
68

PRP
kVA
85

kWe
68

kVA
85

60 Hz

84

105

84

105

50 Hz

120

150

120

150

60 Hz

132

165

132

165

50 Hz

264

330

264

330

60 Hz

280

350

280

350

50 Hz

320

400

320

400

60 Hz

360

450

360

450

50 Hz

304

380

336

420

60 Hz

344

430

344

430

50 Hz

400

500

440

550

60 Hz

464

580

464

580

50 Hz
60 Hz

613
700

765
875

676
700

845
875

Continuous power (COP)

Prime running power (PRP)

Limited time running power

Rated load without time or load

Variable load with mean power calculated on

Variable load with mean power calculated on

factor limitation

250 running hours

250 running hours

No restriction on use if mean power 75% of


nominal power

No overload

Total operating time at 100% nominal power

power 85% of rated power)

(consult us)

Typical hours per year 500 hours (with mean

shall not exceed 500 hours per year

Total operating time at 100% rated power shall

10% overload available 1 hour each 12 hours

not exceed 25 hours per year


Maximum continuous running time at 100%
rated power: 1 hour each 12 hours

3 PHASES SYNCHRONOUS GENERATOR

OPTIONAL EQUIPMENTS

Frequency

50/60 Hz - 4 poles

Cooling by keel cooling

H/H

High efficiency air filter

Insulation / Heating class


Voltage regulation
Excitation
Protection / Impregnation

Electronic

Exhaust silencer

Brushless

Water injection type exhaust elbow

IP23 / Marine

Bearing

(extract)

Remote control panel

Sealed, life lubricated

SPECIFIC FUEL CONSUMPTION

4 W105S
6 W105S
6 W126S
6 M19.3
6 M26.2
8 M26.2
12 M26.2

HZ

PRP
kVA

kWe

50
60
50
60
50
60
50
60
50
60
50
60
50
60

85
105
150
170
340
350
400
450
420
430
555
580
745
875

68
84
120
136
272
280
320
360
336
344
444
464
596
700

100% PRP

kWm
75
92
129
145
290
300
330
380
355
368
473
491
710
736

75% PRP

g/kWh
194
198
193
204
198
205
199
202
194
198
210
217
196
199

kWm
56
69
97
109
218
225
248
285
266
276
355
368
533
552

50% PRP

g/kWh
196
197
194
207
201
206
198
194
195
205
211
218
196
200

kWm
38
46
65
73
145
150
165
190
178
184
237
246
355
368

g/kWh
205
213
204
220
204
209
208
201
202
220
215
226
199
208

DIMENSIONS
kVA
50 Hz

kVA
60 Hz

Kg (dry)

4 W105S

85

105

1 680

870

1 285

1 100

6 W105S

100 / 150

120 / 170

2 187

800

1 216

1 500

170 / 260

205 / 300

2 584

994

1 619

2 145

6 W126S

270 - 340

325 / 350

2 726

994

1 619

2 371

6 M19.3

400

450

3 239

994

1 320

3 025

6 M26.2

420

430

3 043

1 164

1 414

3 550

8 M26.2

555

580

2 996

1 482

1 575

4 585

12 M26.2

875

875

3 878

1 456

1 575

6 130

Socit Internationale des Moteurs Baudouin


Technoparc du Brgadan - CS 50001 - 13711 Cassis Cedex - France - tl. +33 488 688 500 - fax +33 488 588 501 - www.moteurs-baudouin.com

Moteurs Baudouin reserve the right to modify these specifications, without notice. Document not contractual.

FUEL CONSUMPTION PERFORMANCES (l/h)