Run Sheet No. : : 001/VII/RS/2014 WPS No. : 001/WPS/SMAW R1 Welding Process : SMAW Weld Date : 8 July 2014 SOP No. : - Base Metal : SA 516 Gr. 70 Coupon No. : 001 Page : 1 of 1 No Process Welder ID Layer No Weld Time Total Heat Input Wire feet speed Travel speed Diameter Spec/SFA Class Brand Spec Class Brand Type % Mix Preheat (C) Interpass (C) Voltage Amphere AC DC Transfer Mode (mm/min) (mm/min) 1 SWAW Rivaldy root 10 min 2.6 5.1 E7016 Kobelco N.A N.A N.A N.A N.A 32 - 20 70 - EP N.A 2100 N.A 40 (Z 83) fill 9 min 3.2 5.1 E7016 Antlantic N.A N.A N.A N.A N.A 65 120 19 105 - EP N.A 2394 N.A 50 fill 12 min 3.2 5.1 E7016 Antlantic N.A N.A N.A N.A N.A 65 110 19 105 - EP N.A 3420 N.A 35 cap 11 min 3.2 5.1 E7016 Antlantic N.A N.A N.A N.A N.A 67 121 19 95 - EP N.A 3094.28571 N.A 35 Note : - calculating Heat Input using formula in QW-409.1 (a) - dimension of test coupon = L. 270 x W. 280 x t. 12 1. Visual Examination 2. Non Destractive Examination Examined by Type of Test : Radiography Test Tested by Size (mm) Test Result : ACC - Ade Ruhiyat Welding Engineer Abdul Djalal Welding Engineer SEE ATTACHMENT 3. Destructive Examination TENSILE TEST CHARPHY TEST BEND TEST Area Load Speciment Defect Remarks Width (mm) Thicness (mm) (mm2) (kgf) (kgf/mm) (Mpa) (PSI) No Type Size - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4. Judgement PASS RE-TEST FAIL RUN SHEET Others Information Consumable Used Heating Electrical Parameter Unit : mm Filler Flux Gas (Average) Defect Type Welding Area Approved by Approved by (QC Inspector) (QC. Engineer) (Welding Engineer) Location Speciment No Size Tensile Stress Speciment No Location No Energy SEE ATTACHMENT SEE ATTACHMENT Supervised by Accepted by Approved by - - Visual Examination ACC