Вы находитесь на странице: 1из 12

Siemens AG 2009

Reliable and Precise Overview Over


Electrical Characteristics and Power
SENTRON PAC Power Monitoring Devices

Power Management
Answers for industry.

Siemens AG 2009

When and where is how much power consumed?


SENTRON PAC makes consumption apparent

A sustainable reduction of power costs first requires an analysis of the electrical systems current
consumption and power flows. This is supported by our SENTRON PAC3200 and SENTRON PAC4200
power monitoring devices. They precisely and reliably detect the power values of electrical feeders
and individual consumers. In addition, they provide important measured values for assessing the
system state and power quality.

Whether in industrial applications or commercial buildings


our SENTRON PAC power monitoring devices can be
employed wherever electric power is distributed. They
detect various measuring values and comfortably illustrate them on a graphical LC display. For further processing of the measured data, the devices can be very easily
integrated in superior automation and power management systems, for example in our SIMATIC PCS 7 powerrate and SIMATIC WinCC powerrate software packages.
Precise power measuring matched to your needs
The two power monitoring devices provide accurate
knowledge of your systems characteristics with
maximum, minimum and average values for voltage,
current, power values, frequency, power factor,
symmetry and THD.

While the SENTRON PAC3200 detects more than 50


basic values, the SENTRON PAC4200 offers a total
of 200 values with further relevant data regarding
the power quality. Both devices feature 10 power
counters for comprehensive load detection. Their
measuring accuracy meets the high requirements
found in the power counter standards, thanks to which
they are excellently suited for internal accounting.
The SENTRON PAC4200 offers a considerably higher
measuring accuracy than its smaller brother. Moreover,
its on board logging capabilities and individually
configurable screen displays provide additional comfort
and for ease of evaluation of the data.

Siemens AG 2009

Fast and space-saving installation


Minimum space requirements thanks to compact design:
Panel-mounting format: 96 x 96 mm (3.78" x 3.78")
Installation depth in switch panel:
SENTRON PAC3200:
51 mm (2"), 73 mm (2.88") with expansion module
SENTRON PAC4200:
77 mm (3"), 99 mm (3.89") with expansion module
Easy mounting:
Mounting without tools with easily latching retainers;
additional support of uncomplicated screw fastening for increased
degree of protection
Easy operation and configuration
Intuitive menu prompt via 4 function keys
Plain text displays in 9 languages
Optimum readability of the LC display thanks to adjustable
background illumination
Time-saving configuration of multiple devices via free SENTRON
powerconfig software (included with each device)

Versatile application range


Direct connection to industrial networks up to 690 V, CAT III
Support use of potential transformer
Connection to current transformer x/1 A or x/5 A
Application in systems with UL/CSA requirements
Application in harsh environments: dust and splash water protection
(IP 65 / NEMA 12) through standard spray-on sealing
Developed and tested in accordance with European and international
standards

Siemens AG 2009

From integrated communication


Our power monitoring devices facilitate flexibility thanks to multiple communication
options. Whether PROFIBUS DP, Modbus RTU or Ethernet with Modbus TCP
integration in superior systems is ever so easy with the SENTRON PAC3200 and
SENTRON PAC4200.

Ethernet on board
Both the PAC3200 and PAC4200 come
standard with an Ethernet interface built in
making additional hardware unnecessary
saving space and money. The devices can be
configured via LAN networks and reliably
provide measured data via Modbus TCP.
Yet, the flexible power monitoring devices
offer further alternatives for integrated
data transmission:
PAC PROFIBUS DP expansion module
Data transmission via PROFIBUS DP,
cyclic and acyclic data traffic via
PROFIBUS DPV1
Transmission rates of up to 12 MBit/sec
Easy (plug-in) mounting on rear device
side

PAC RS485 expansion module


Data transmission via Modbus RTU
and SEAbus
Transmission rates of up to 38.4 kBd
Easy (plug-in) mounting on rear
device side

Digital inputs and outputs


The SENTRON PAC3200 features one
multifunctional digital input and output
each and the SENTRON PAC4200 comes
with two multifunctional digital inputs
and outputs. One of up to six possible
functions can be independently assigned
to every input and output according
to your individual requirements. This
provides you with maximum flexibility
and reduces the implementation costs
for system adjustments.

Integrated Ethernet
interface
PAC PROFIBUS DP
expansion module

PAC RS485 expansion


module

Digital inputs and


outputs

Siemens AG 2009

to systematic power management


Exploit the full potential of our power monitoring devices by integrating them in a superior power
management system. The precise and comprehensive measuring functions of the SENTRON PAC3200 and
SENTRON PAC4200 provide the required measured data. Together with power management add-ons and
block libraries, Siemens offers an innovative and future-proof solution for optimized power utilization with
up to 20 % saving potentials in terms of power costs.

SIMATIC PCS 7 powerrate and


SIMATIC WinCC powerrate
Power management par excellence based
on tried-and-tested industrial technology:
Our power monitoring devices can be easily
coupled with the SIMATIC PCS 7 powerrate
and SIMATIC WinCC powerrate power
management add-ons. Comprehensive
measured value detection and processing
as well as cost-by-cause allocation support
the transparency and control of your power
distribution system and costs. The load
management functionality represents a
further highlight. This feature monitors the
power limit agreed with the power supplier
and controls the consumption if required.

System integration via block libraries


The optionally available block libraries support the easy integration of the SENTRON PAC
devices in the SIMATIC PCS 7 process control
system and the SIMATIC WinCC SCADA system. Together with the faceplates, the driver
and diagnostics blocks in the control serves
as the user interface for operating and monitoring. This way, all technologically important
values and functions of the power monitoring devices can be easily displayed and used
in the respective target system.

Faceplates

Industrial Ethernet

PROFIBUS

S7 drivers/blocks

Siemens AG 2009

SENTRON PAC3200
The basis for reliable and precise measuring

Flexible
The SENTRON PAC3200 detects more
than 50 electrical characteristics such as
voltages, currents, ratings, power values,
frequency, power factor, symmetry and
THD. In addition to the current measured
value, the minimum and maximum
values are detected for the measuring
values (non-return pointer function).
The SENTRON PAC3200 is designed
for measuring applications in singleor multi-phase networks with and
without neutral conductor. A particularity
of this device is that it supports the
direct measuring of phase voltages up
to 830 V. The SENTRON PAC3200 can
thus be employed in 690 V networks.
Furthermore, measuring via potential
transformers is possible with the
transformation ratio respectively
adjustable. The current inputs are
dimensioned for measuring on x/1 A
or x/5 A current transformers.

and precise measuring


The SENTRON PAC3200 detects the values
for active, reactive and apparent energy
both for high and low tariff. It measures
ratings and power values via the four
quadrants, i.e. power import and export
are measured separately. The SENTRON
PAC3200 also facilitates the detection
of a measuring periods average values
for active and reactive power. These
values can be further processed into load
curves in a power management system.
Typically, 15-minute intervals are used for
this purpose.

The measuring accuracy are 0.5 % for


active energy and power and to 0.3 % for
voltages and 0.2 % for currents.
The device allows for the monitoring
of up to six parameters for an upper or
lower limit value. The six limit values can
be interlinked via the integrated logic
function.
The SENTRON PAC3200 is equipped with
one multifunctional digital input and
output as a standard. The output can be
used as pulse or switching output or for
limit value signaling. The input can, for
example, be used for switchover between
high and low tariff detection or for the
pulse counting of power counters with
S0 interface.

Siemens AG 2009

Features
Basic measuring values
Voltage
Current

PAC3200

PAC4200

L-L, L-N, 3-phase average

Per phase, 3-phase average

Neutral conductor current


Apparent power

Per phase and total

Active power

Per phase and total

Total reactive power

Per phase and total

Fundamental wave reactive power

Per phase and total

Power factor

Per phase and total

Fundamental wave power factor

Per phase

Frequency

Of import phase

Min./max. values / date and time

Non-return pointer function

Moving average values

U, I, S, P, Q, LF

Phase displacement angle

Between voltage and current per


phase

Phase angle

Between phase voltages

THD voltage

Per phase

THD-R (UL-N)

THD (UL-N & UL-L)

Extended measuring values

THD current

Per phase

THD-R (IL1..3)

THD (IL1..3)

Harmonics voltage

Per phase

3rd to 31st

Harmonics current

Per phase

3rd to 31st

Distortion current strength

Per phase

Max. values / date and time

Non-return pointer function

Asymmetry voltage / current

3-phase system

Unba / Inba

Unb / Inb

Apparent energy

Continuous counter total energy

Active energy

Continuous counter total energy

Import and export

Reactive energy

Continuous counter total energy

Import and export

2 tariff counters (HT / LT)

Apparent, active, reactive energy

Daily power values for 365 days

Apparent, active, reactive energy

Power demand of last measuring period

Active and reactive power


average value

Measuring period

Adjustable in minutes

Min./max. values of ratings

Within the measuring period

Operating hours counter

Operating period consumers

Universal counter

Multifunctional

Limit value monitoring

Max. number of limit values

12

Boolean logic

AND, OR / NAND, NOR, XOR, XNOR /

Limit values / inputs

Logically interlinkable

Power detection / counters

Monitoring functions

Siemens AG 2009

Recording functions

PAC3200

PAC4200

Load curve recording

Apparent, active, reactive power average values

Min./max. values

Per measuring period

Recording period

With 15-min. measuring period

40 days

Synchronization

Digital input, bus, internal clock

Adjustable averaging

Arithmetic or accumulated

Recording methods

Fixed block or rolling block

Event recording

Max. number of events

> 4000

Priority control

Selectable warning levels

Adjustable acknowledgement
requirement

Selectable event storage

Interfaces
Ethernet (integrated)

For twisted-pair cables

10 Mbit/sec

10/100 Mbit/sec

Interface functions

Auto-negotiation / auto MDI(X)

Number of connections

Simultaneous

Protocol

Modbus TCP

Gateway

Ethernet RS485 (Modbus)

PROFIBUS DPV1

Via PAC PROFIBUS DP module

Optional expansion module

Modbus RTU

Via PAC RS485 module

Optional expansion module

Inputs / outputs
Digital inputs

Multifunctional

Digital outputs

Multifunctional

Operating voltage DI/DO

Nominal value

24 V DC

24 V DC

Real-time clock

Second-accurate time stamp

Calendar function

Adjustable date and time format

Summertime / wintertime switchover

Automatic (US/EU) or manual

Voltage / current

Referred to the measured value

0.3 % / 0.2 %

0.2 %*

Apparent / active / reactive power

Referred to the measured value

0.5 % / 0.5 % / 2 %

0.5 % / 0.2 % / 1 %

Active energy

According to 62053-22

Class 0.5S

Class 0.2S

Reactive energy

According to 62053-23

Class 2

Class 2

Clock / calendar

Fault limits

Display / operation
Display

LCD graphical display with background illumination

Indication

Alphanumeric and text

Operation

Fully graphical

Menu prompt via function keys

Languages

Selectable on the device

User-definable indication

Bar or digital indication

* Complies with the stated function-related accuracy classes in accordance with IEC 61557-12
Unba | Inba Asymmetry with regard to amplitude
Unb | Inb Asymmetry with regard to amplitude and phase

GER, ENG, PT, TR, ES, IT, FR, CHN, RU

Siemens AG 2009

SENTRON PAC4200
Comprehensive and comfortable overview of the system state

You require detailed knowledge of your systems state? Then the SENTRON PAC4200
is the right solution for you. It detects
approximately 200 electrical characteristics. In addition to over 50 basic
values, which are also provided by the
SENTRON PAC3200, you can thus also
generate measured data for assessment
of the power quality. Besides the THD for
three- and four-conductor networks, the
PAC4200 also detects uneven harmonics
from the 3rd to the 31st for voltage and
current, the distortion current strength
(Id), the phase angle and the asymmetry
for voltage and current with reference to
the amplitude and phase. This facilitates
early counter-measures against interferences, e.g. caused by mains pollution.
Maximum precision and safety
The PAC4200 sets new precision standards
in its device class. With an accuracy of
0.2 % for voltages, currents, active power
and energy, referred to the measured
value in accordance with IEC 61557-12,
this device is not only highly precise,

but also complies with the latest standards.


This guarantees the power monitoring
devices suitability regarding the requirements of modern industrial systems in
terms of performance, safety and operating behavior.

User-defined screen displays


A total of four individually configurable
screen displays offers further comfort. You
can have the values displayed as bar chart
or have them compiled as digital indication to gain a rapid overview of your systems state directly on the device.

Comprehensive storage functions


Integrated gateway function
The SENTRON PAC4200 stores load curves
in its internal memory. Apparent, active
and reactive power average values are
stored over a period of 40 days with a
15-minute measuring period. These data
form the basis for an accurate determination and optimization of your systems
utilization for reduced power costs and
improved system efficiency.
The PAC4200 supports the recording of
more than 4000 operating and system
events, which can be individually
adjusted. With an integrated real-time
clock, all events can be traced accurate to
the second. This saves valuable troubleshooting time in case of faults.

The integrated gateway function of the


SENTRON PAC4200 allows for the convenient integration of devices with simple
serial RS485 interface in an Ethernet network. This way, several subordinate devices, e.g. simple measuring devices or
circuit breakers, can send their data to
the SENTRON PAC4200 via Modbus RTU.
The SENTRON PAC4200 for example
forwards this data to a supervising power
management system via its integrated
10/100 MBit/sec Ethernet interface.

Connection of Modbus RTU devices to a power management system via


SENTRON PAC4200
Server

Client

Client

SQL
database

Ethernet
SENTRON PAC4200 with
serial gateway
Modbus RTU

SENTRON VL

SENTRON WL

SENTRON
PAC3200

Multifunction measuring devices

Siemens AG 2009

Technical data

SENTRON PAC3200

SENTRON PAC4200

Applicable for TN, TT, IT networks

Continuous signal detection

Measuring / supply voltages


Measuring inputs for voltage
Wide voltage power supply unit
Measuring inputs for voltage

3 AC; UL-L/UL-N; CAT III

Max. 690 V / 400 V

AC/DC

95 to 240 V AC 50/60 Hz 10 %
110 to 340 V DC 10 %

3 AC; UL-L/UL-N; CAT III

Max. 500 V / 289 V

DC

22 to 65 V DC; 10 %

Measuring on voltage transformers

For voltages > 500 V or


690 V

Measuring inputs for current

3 AC; CAT III

Current direction

programmable

Extra-low voltage power supply unit

Measuring via current transformer

x/1 A or x/5 A

Per phase

Mechanics
Dimensions

W x H x D [mm]

96 x 96 x 56

96 x 96 x 82

Installation depth without module

[mm]

51

77

Installation depth with module

[mm]

73

99

II

II

Protection class
Degree of protection

Front

IP65

IP65

Slots for expansion modules

Number

10 ... +55

10 ... +55

95 %

95 %

Operating temperature C
Relative humidity during operation

Up to 25 C without
condensation

Pollution degree
Approvals
CE

Europe

cULus

USA / Canada

C-Tick

Australia

In preparation

GOST

Russia

Accessories
PAC PROFIBUS DP expansion module (optional)
Parameterizable via device front or parameterization software

Selection of measuring values to be transmitted via GSD file

Transmission rate

9.6 Kbit/sec to 12 Mbit/sec

Protocol

DPV1

PAC RS485 expansion module (optional)


Parameterizable via device front or parameterization software

Transmission rate

Optionally 4.8 / 9.6 / 19.2 / 38.4 kBd

Protocol

Optionally SEAbus or Modbus RTU (selectable)

10

Siemens AG 2009

Ordering information

Product

Uc

Order number

SENTRON PAC3200 power monitoring device


with AC/DC wide voltage power supply unit and screw
terminals

95 to 240 V AC 50/60 Hz 10 %
110 to 340 V DC 10 %

7KM2112-0BA00-3AA0

SENTRON PAC3200 power monitoring device


with DC extra-low voltage power supply unit and screw
terminals

22 to 65 V DC 10 %

7KM2111-1BA00-3AA0

SENTRON PAC3200 power monitoring device


with AC/DC wide voltage power supply unit and
ring cable lug terminals

95 to 240 V AC 50/60 Hz 10 %
110 to 340 V DC 10 %

7KM2112-0BA00-2AA0

SENTRON PAC4200 power monitoring device


with AC/DC wide voltage power supply unit and screw
terminals

95 to 240 V AC 10 %
110 to 340 V DC 10 %

7KM4212-0BA00-3AA0

SENTRON PAC4200 power monitoring device


with AC/DC wide voltage power supply unit and
ring cable lug terminals

95 to 240 V AC 10 %
110 to 340 V DC 10 %

7KM4212-0BA00-2AA0

Accessories
Product

Order number

PAC PROFIBUS DP expansion module

DPV1; up to 12 MBit/sec

7KM9300-0AB00-0AA0

PAC RS485 expansion module

Modbus RTU / SEAbus up to 38.4


kBd

7KM9300-0AM00-0AA0

SIMATIC PCS 7 Library PAC3200

Engineering + runtime license

3ZS2781-1CC10-0YG0

Runtime license

3ZS2781-1CC10-6YH0

Engineering + runtime license

3ZS2791-1CC10-0YG0

Runtime license

3ZS2791-1CC10-6YH0

Library PAC3200
for SIMATIC WinCC

Information on the SIMATIC PCS 7 powerrate and SIMATIC WinCC powerrate power management add-ons as well as on the
power management system is available at www.siemens.com/powermanagementsystem

11

Siemens AG 2009

For further information


... please contact your local Siemens sales partner.
For technical questions, please contact:
Technical Assistance
Tel.: +49 (911) 895-5900
E-mail: technical-assistance@siemens.com

Siemens AG
Industry Sector
Low-Voltage Controls and Distribution
P.O. Box 48 48
90026 NRNBERG
GERMANY

Subject to change without prior notice 01/09


Order No. E20001-A460-P307-V3-7600
Dispo 27605
2100/17907 EVPM.52.9.03 PA 01097.0
Printed in Germany
Siemens AG 2009

www.siemens.com/powermanagementsystem

The information provided in this brochure contains merely


general descriptions or characteristics of performance which
in actual case of use do not always apply as described or
which may change as a result of further development of the
products. An obligation to provide the respective
characteristics shall only exist if expressly agreed in the
terms of contract.
All product designations may be trademarks or product
names of Siemens AG or supplier companies whose use by
third parties for their own purposes could violate the rights
of the owners.

Вам также может понравиться