Graphite Digestion System

TM

ECOPRE

BaekDu

TM

CUSTOMER CENTER TEL.82-2-809-7847,82-2-809-7848 www.odlab.co.kr

About ODLAB

ODLAB has been manufacturing Graphite Digestion System including

heavy metal pollution using graphite instead of aluminum.

EcoPre hotplates, Graphite blocks and BaekDu Teflon digestion vessels

Furthermore, BaekDu is Teflon coated to resist a corrosive attack for

and we also have been providing Certified Reference Materials(CRMs)

guaranteed long life and protect an analyst from harmful gas.

and consumables for AAS, ICP, ICP-MS since August 2008.

ODLAB is very proud that we have developed and commercialized high

In order to improve on previous hotplates and digestion vessels, we have

quality products such as BaekDu Teflon digestion vessels and Pressure

developed our own Graphite Digestion System. We recommend our

digestion vessels for the first time in the world and obtained international

products for companies which have much trouble with getting an accurate

patents in Korea, China, Canada, Germany, U.K., U.S.A., and so on.

TM

TM

TM

data due to corrosion of the fume hood or hotplate or pollution of existing


products in a harsh laboratory environment. It is possible to prevent

Sincerely,
CEO Young

Rok Eum

Graphite Digestion System

LABTER .

LABTER ECOPRE .

ECOPRE Series Hotplates

Teflon coated to prevent corrosion and pollution


Support various sizes from 300x200 600x300mm
Up to 250 temperature control (200 240V)

Controllers

Separated the control mode for flexible operation


New touch screen controller

BaekDu Teflon Digestion Vessels


TM

Graphite Blocks

Teflon coated blocks to resist corrosion


User friendly custom-made blocks

Patent rights in 7 countries.


Duponts 440HP high purity material
Support 60ml, 100ml, and 300ml
Collect volatile elements and acid

BaekDu Digestion Vessels


TM

Emission/Injection
part

6Hole

Screw
Screw

Design

A high purity PFA Teflon digestion vessel is comprised


of Digestion vessel and Collection tube.
When the vapor from Digestion vessel passes
reversed U-tube, the vapor is air-cooled and
condensed and the gas is emitted to the highest part of
the Collection tube. Each part is designed to be tightened
by turning screws to maintain the reacting pressure.

Features

Made of the 440HP PFA Teflon material produced by DuPont.


in the U.S.A.
Heated up to approximately 260 in the continuous temperature.
Digested by recycling after adding acid once.
Collect and digest volatile elements like Hg, As, B by Collection tube.
Protect an analyst from harmful gas generated by pre-treatment and
extend the life of the fume hood in a lab.
Used longer time than glass tubes and saved experimental cost.

BaekDu Digestion Vessels


TM

Collection Tube
Cover
Tube
Middle tube

Digestion Vessel
1.Add Acid and sample
2. Heated sample is
in vessel and add
air cooled and
1% 5% HNO3 in Collection condensed in collection
tube and start heating.
tube
Condense/extract
-1 STEP

Condense/extract
-2STEP

3.When all sample are


heated the reaction
Pressure falls
Condense/extract

4.The Acid in collection


tube automatically
fall to digestion vessel

5.Through reheating
the sample reheats
for the acid to be
cycled and digested

-3STEP(END)

Sequential Processing
After heating is started, heated acid gas passes the reversed U-tube. Acid gas meets cold air to be air-cooled and
condensed and then it is accumulated in the collection tube. Once all acid in the digestion vessel moves up to the
collection tube, reacting pressure gets lower and the liquid in the collection tube starts to drop to the digestion vessel.
This processing is repeated by reheating until the sample decomposition is completed.

Patents for BaekDu Digestion Vessels


TM

What does BaekDu mean?


TM

The highest and most famous mountain in Korea is Mt. Baekdu. It is located on the border between Korea and China.
There are the crystal clear blue lake in the center of the top and beautiful plants
and various animals are living peacefully. We thought our product,
Teflon Digestion vessel looks like Mt.Baekdu so we named it BaekDu.

Japan

Canada

China

Germany

India

U.S.A

U.K.

Korea

Products ECOPRE series


ECOPRE-I

No: OD-98-001

Size(mm): 600W x 300L x 35H


Temperature : Up to 250
Teflon Coated Graphite

No: OD-98-002

Size(mm): 400W x 300L x 35H


Temperature : Up to 250
Teflon Coated Graphite

Size(mm): 300W x 210L x 35H


Temperature : Up to 250
Teflon Coated Graphite

ECOPRE-III

ECOPRE-II

No: OD-98-003

ECOPRE-HT

No: OD-98-004

Size(mm): 300W x 230L x 35H


Temperature : Up to 500
Special Coated Graphite

Products ECOPRE series

Graphite Block (Narrow)


No : OD-98-12Holes
Size(mm) : 400W x 150L x 30H
Teflon Coated

Graphite Block (Small)


No: OD-98-15Holes
Size(mm): 300W x 210L x 30H
Teflon Coated

Graphite Block (Medium)


No: OD-98-24 Holes
Size(mm): 400W x 300L x 30H
Teflon Coated

Graphite Block (Custom-made)


Flexible size to meet
customers'needs
Teflon Coated

Graphite Block (Large)


No: OD-98-45 Holes
Size(mm): 600W x 300L x 30H
Teflon Coated

Products Digestion Teflon Vessels

BaekDu Digestion Teflon Vessel Size


300ml : OD-98-300
100ml : OD-98-100
TM

BaekDu Digestion Teflon Vessel


Size: 60ml or 100ml
TM

60ml : OD-98-60

Pressure Digestion Teflon Vessel Size


100ml : OD-98-100P
60ml : OD-98-60P
30ml : OD-98-30P
15ml : OD-98-15P

BaekDu Digestion Teflon Vessel


Size: 300ml
TM

Pressure Digestion Teflon Vessel


Size: 15ml, 30ml, 60ml and 100ml
Pressured digestion by 75psi
Appropriate to bio samples or micro size analysis
Digestion without loss for volatile elements

Products Accessories

Wrench
No: OD-Wrench-S(B)
To open and close Pressure Digestion vessels
for 60ml,100ml or Digestion vessels for 300ml

Brush for cleaning vessels


No: OD-98-Cleaner
Size: 18cm
Sponge and Plastic
To clean Teflon digestion vessels

Teflon only pen


No: OD-98-PEN
Only Teflon pen is available to mark on the
Teflon digestion vessels

Filter Paper
No: OD-98-FM (for 37 Heavy metal)
OD-98-FCR (for 37 Chromium )
Qty.: 100EA/Box

Filter Manifold
No: OD-98-Manifold
Size: 8 Valves to open and close
No corrosion with plastic material
Used with a vacuum pump for filtering

Rack
No: OD-98-RACK Size: 12 Holes
Poly Carbonated material
Height adjustment possible
To transport vessels or use for filtering
a sample

10

Products Magnetic Stirrer

Stirrer

No: OD-98-Stirrer (Same as below)


Built-in controller
Plastic material to prevent corrosion
Available to control speed of motor

Teflon Bar

No: OD-98-Bar
Size(mm): 15x4
TM
Teflon coated circle bar for the Teflon digestion vessel, BaekDu

Hotplate and Stirrer


No: OD-98 Stirrer
Size(mm): 400x120
Installed below Graphite hotplate

11

Products

Teflon Cleaner & Gas Neutralizer

Graphite Teflon Cleaner


No: OD-98-GTC
Size: Graphite (340x70) &
Teflon Tank (320x360)
To clean various kinds of vessels
adding diluted acid
Diluted acid can be recycled

Neutralizer of Harmful Gas

No: OD-98-HGN
Size: 350x370x400
Voltage : AC220V, 50/60Hz
Neutralized by H2O and NaOH

Clean Fume hood


No: OD-98-CH
Size (mm) : 1200 or 1500 or 1800
No corrosion with tempered
PVC material
Safe from harmful gas or acid vapor

Teflon Gas Collection Plate

No: OD-98-CP
Size: 450x350
Made by heated PTFE
24 holes are sending harmful gas
from Digestion vessel to Neutralizer

12

Application
1. Condition of Digestion - Soil (by DIN ISO11466)
1.5g : Add HNO3 3.5ml and HCl 10.5ml to Digestion vessel
3g : Add HNO3 7ml and HCl 21ml to Digestion vessel
Insert 0.5M HNO3 7.5ml into Collection tube
After adding Acid, let stand at room temperature for 2 hours

Insert 1.5g or 3g of the sample


into Digestion vessel

Digest at 130C for 2 hours

After cooling, move remained liquid in


Collection tube to Digestion vessel.
Clean Collection tube using distilled water
and move it to Digestion vessel, too

Mass-up (1.5g to 50ml, 3g to 100ml)/


Filtering (OD-98-FM)/Measure

Clean up Digestion vessel using a


detergent and then make a cleansing
solution at the rate of distilled water 7:
HNO3 2: HCl1 and heat them up

13

Application
2. Condition of Digestion-Dried Shrimp(available to similar samples)
Insert 1g of the sample into Digestion
vessel

Add HNO3 15ml, HCl 3ml, and Perchloric acid 0.5ml to


Digestion vessel
Insert 1% HNO3 6ml into Collection tube

Heating at 220C and temperature down


to 150C(Repeat this step three times)

Use HCl if the sample includes lots of


Ca like an anchovy because sulfuric
acid may cause precipitate

Analyze 50ml mass-up

14

Application
3. Condition of Digestion - Chrome VI(EPA-3060A)
Dilute NaOH 20g and Na2Co3 30g with 1L distilled water to
make the digestion solution
Add 50ml digestion solution heated to 90C 95C
Add MgCl2 0.4g
Add 0.1M Phosphate buffer 0.5mL

Control PH7.5 0.5 using 5M HNO3


(Digest again if the range is out of PH7.5 0.5)
Clean up Digestion vessel using distilled water

nsert 1.5g
the sampleI
Insert
2.5g or
of 3g
theofsample
into Digestion
into Digestion vessel
vessel

Cover the collection tube with a watch


glass and stir for 5 min.

Heat up to 90C
60 min.

95C and stir for

Cool at room temperature and filter


(OD-98-FCR)

Analyze 100ml mass-up UV

15

Application
4. Condition of Digestion-Sludge, Precipitate

Add HNO3 4ml, Hydrofluoric acid 3ml, and Perchloric


acid 1ml to Pressure vessel

Insert 0.2g of the sample into Pressure


vessel

Keep uncovered and Heat to 100C for about 40 minutes

If digestion is not completed, digest again adding


HNO3 3ml, Hydrofluoric acid 1ml

Close the cover of Pressure vessel using


a wrench and heat up to 200C for
5 hours.
Dry up at 100C after cooling

Mass-up / Filtering (If necessary)/


Measure

Clean up Pressure vessel using a


detergent and then make the cleansing
solution 20ml at the rate of distilled
water 6 : HNO3 2 : HF 2 and heat
them up

16

Products

Available Consumables

CRM Supplies

Provide Certified Reference Materials domestically


and internationally such as RoHS related standard
substance, soil, bio, water, metal, and so on

Standard Solution

High purity/Ultra high purity Acid

Single element, multi elements solution, Oil


standard solution for AAS,ICP, ICP-MS, IC, or XRF
Can be Custom-made

Recommended for micro analysis such as


ICP-MS or GF-AAS
Supplied by 100ppt and 10ppt

Bottle Top Dispenser


TruFlo Sample Monitor
Accuracy improvement for ICP-OES and ICP-MS test
Reduces sample repeats and sounds out-of-range alarm

Dispensing small volumes of high purity acids


from a bottle safely and reliably
Convenient and safe traditional bottle-top pump style

17

Products

Available Machines

Desktop Swing Mill HK40


Product for effective grinding or mineral
based samples
Size(mm): 345x295x540
Compact size including emergency
shutdown function

SpectroMill
SpectroMill Ball Pestle Impact Grinders for
grinding and blending XRF samples
Process single or multiple samples at the
same time
Programmable timer with LCD display

Laboratory Press PE-MAN


Compact sized machine for X-ray and
IR sample pelletizing
Covered in solid steel housing to save
maintenance cost

ISOMIST
The ultimate spray chamber for ICP-MS and ICP-OES
Programmable temperature between -10C and +60C
Reduced oxide interfaces in ICP-MS

18

User List

College of Agriculture and Life Science in Seoul National University


Korea Coast Guard R&D Center and branches
Gangwondo Agricultural Research and Extension Services
NAQS, National Agricultural Products Quality Management
Service in Gangwon-Do
KBSI, Korea Basic Science Institute
NVRQS, National Veterinary Research & Quarantine Service
Animal and Plant Quarantine Agency
RIST, Research Institute of Industrial Science & Technology

National Institute of Environmental Research


Samsung Engineering
National Academy of Agricultural Science
Ministry of Food and Drug Safety
Forestry Comprehensive Research Center in Japan
(), TORAY Innovation by Chemistry in Japan
(), SCAS, Ltd. in Japan
(), Showa Giken Industrial Co., Ltd. In Japan
And other 300 companies

19

Order Information / Sales Policy


ODLAB could deliver the products within 1~5 weeks after checking your deposit.
Please send the purchase order by fax or E-mail.
The freight charges and taxes should be paid by the customer.
There will be an additional 30 US$ fee for the handling charge.
ODLAB Graphite Digestion System products are guaranteed free of charge for one year, However, the
company can not accept liability for any damages caused by natural disasters or customers' fault.
Address : 632, Kwang Myung Industrial Complex, 201, Haan3-dong, Kwang Myung-si, KyungGi-do,
Republic of Korea (zip: 423-754)
Tel :
+82-2-809-7847/8
Fax :
+82-2-6405-7848
E-mail : sales@odlab.co.kr / umrok@hanmail.net
Home page : www.odlab.co.kr

20

Вам также может понравиться