Troubleshooting GP-2000
Technical Knowledge
International Dept.
Fact example
Problem
Pressure gauge is broken
Solutions
Replace the pressure gauge
International Dept.
Fact example
Problem
By-pass valve has leakage
Solutions
Replace isolation valve
International Dept.
Problems caused by other factors does not reach the set pressure
Fact example
Solutions
Problem
Condensate at outlet side
Condensate
Problems caused by other factors does not reach the set pressure
Fact example
Conditions:
*Inlet : 0.5MPa, pipe size 50A
Outlet : 0.2MPa, pipe size 50A
Steam capacity : 600 kg/h
Problem
Pipe size at outlet side is too small !!
*0.5MPa Pipe size 50A, Velocity : 35.6 m/s
*0.2MPa Pipe size 50A, Velocity : 130 m/s
Solutions
Velocity : 20 40 m/s
50A
65A
Bigger size
Problems caused by other factors does not reach the set pressure
Fact example
Conditions:
*Decrease in outlet pressure
Globe
Valve
Problem
The pressure loss is caused by Globe valve.
Solutions
*Should install gate valve which has less
pressure loss comparing to globe valve.
*Select proper size of valve after PRV.
International Dept.
Problems caused by other factors does not reach the set pressure
Fact example
Condensate in the piping and
bottom diaphragm case
Problem
*The pressure at bottom diaphragm cannot
increase because of condensate.
Solutions
*Discharge condensate by opening the
plug at bottom diaphragm case.
International Dept.
International Dept.
Existing piping
-Scales or corrosion exist
International Dept.
International Dept.
International Dept.
Case 2-A : Check if foreign material stuck and scratch at pilot valve or seat.
Case 3-A : Check if foreign material stuck and scratch at main valve and valve seat.
Case 4-A : Check if Pilot diaphragm is damaged?
Case 5-A : Check if External sensing pipe is not installed?
International Dept.
Problem
TEE
Solutions
Orifice A
Clogged
Orifice B
Orifice C
Pressure
Case 2-A : Check if foreign material stuck and scratch at pilot valve or seat.
Phenomenon
Increase in outlet pressure!!
because pilot valve force to open by scale
Problem
Solutions
Size
Consists of
Pilot valve assembly
15A-200A Pilot valve gasket
Pilot diaphragm
Q'ty
1
1
2
Pilot valve
International Dept.
Case 3-A : Check if foreign material stuck and scratch at main valve and valve seat.
Phenomenon
Increase in outlet pressure!!
because main valve tends to open by scales
Solutions
Problem
Leakage because valve cannot close completely
Main valve
Valve seat
Consists of
Main valve
Top body gasket
Bottom body gasket
Main valve spring
Spacer gasket*
*For size 50A-125A
Q'ty
1
1
1
1
1
International Dept.
Case 3-A : Check if foreign material stuck and scratch at main valve or seat.
By-pass
Pressure
gauge
Pressure
gauge
Safety valve
Strainer
Reducer
Stop
valve
Stop
valve
Blow
Joint B
Stop
valve
Drain
separator
Stop
valve
Joint A
Reducer
Stop
valve
GP-2000
Steam Flow
indicator
Trap
International Dept.
Problem
area
Steam
Steam
Steam
Problem
area
Steam
International Dept.
Problem
Solutions
International Dept.
Solutions
Install the external sensing pip.
Problem
Without external sensing pipe, the pilot valve
keeps opening by the adjusting spring force.
Pilot valve will not sense and adjust the
reducing pressure.
International Dept.
Fact example
Installing rising gradient
Problem
Because of accumulation of condensate at
pilot, the pressure transmission to bottom
pilot diaphragm is cut off.
Solutions
Install the external sensing pipe in down
slope position not to have accumulation of
condensate.
International Dept.
Fact example
Conditions:
Piping Drawing
30M
Mixing
Valve
Problem
*Outlet pressure increases up to 0.4MPa after 24 hours, and safety valve blows.
*Accumulation of condensate is cause because of not using for a long period of time.
*Water back flow in the piping system. *Scales stuck at the PRV.
Solutions
*Installing check valve solved the problem, and install trap close to PRV.
International Dept.
Problem
Leakage will be caused and valve cannot open completely because of dirt.
International Dept.
Solutions
Change the parts as pilot assembly
Pilot assembly
Parts kit no.
KS-92110
Size
Consists of
Pilot valve assembly
15A-200A Pilot valve gasket
Pilot diaphragm
Q'ty
1
1
2
International Dept.
Problem
1: Scale problem
-Scales go into diaphragm case
2: Water hammer
-On-off valve or too much
condensate in the piping system
International Dept.
Equalizing line
International Dept.
Problem
Steam cannot go through strainer
because of too much scales
Solutions
Clean up or change the integral strainer
International Dept.
Clogged
TEE
Orifice B
Orifice C
Problem
Steam cannot flow to the bottom
diaphragm case and cannot push up
the diaphragm to lift up the main valve
Solutions
Blow inside of the tee with compressed air.
Problem
Solutions
Blow inside of the external sensing pipe with
compressed air.
International Dept.
Case 6-B : Check if Nominal size is too small for the steam capacity
Fact example
Reduced Pressure
Problem
Solutions
*Select proper size of PRV
*Steam velocity should be 20 to 40 m/s
International Dept.
Fact example
Installing wrong side up
Orifice C
Orifice A (5mm)
Orifice B (4mm)
Orifice B
Orifice C (3mm)
Problem
Orifice A
Solutions
International Dept.
C. Unstable operation
Maintenance procedure
Case 1-C : Pressure reduction ratio is too big
Case 2-C : Nominal size is too large
International Dept.
Problem
*Pressure reduction ratio is 40 : 1
Inlet pressure
2.0MPa
Outlet pressure
0.05MPa
Solutions
Two-stage reduction
3M or more
International Dept.
Tank
Vibration problem
Conditions:
*Flow rate: 30 kg/h
*GP-2000 25A & OB-30 25A
*P1: 0.4MPa, P2: 0.2MPa
International Dept.
Reduced Pressure
Problem
Solutions
*Should install proper size of PRV.
*Installing GP-1000 15A or GD-30 15A to solve the problem.
*Select proper size of the valve between
30 to 80 % of rated flow.
International Dept.