Вы находитесь на странице: 1из 112

Low Voltage Electrical Appliance

Right Quality, Right Price

International Catalogue 2009

Delixi Electric: Who are we

A global company at your service


Delixi was founded in 1984 in Zhejiang province with sales
over 1,5BM, employing more than 15000 people.
Delixi created an international Joint Venture in November
2007,named Delixi Electric LTD,in order to serve you
worldwide,with core LV products having the right quality
at the right price.
Our products are designed for Residential / Building /
Energy / infrastructure and Industrial markets . Delixi
Electric employs 5200 people world wide.

A reliable company serving you with


reliable product
Dedicated R&D center
International quality control of suppliers
International quality control of plants
Fully automatized distribution center
Network of recognized 600 distributors
world wide
Clear warranty policy

Reliable quality

For more details, please contact your local Delixi Electric Company.
Delixi Electric Ltd provides up to 18 months warranty against any defects in
construction arising from faulty designs, material or workmanship.

A company to serve you where you are

We set up companies in many countries in order to deliver best in class


local availability and support .
Delixi Elecric China

Delixi Elecric Southern Africa

Delixi Electric South East Europe

Delixi Liushi Industrial Park,Yueqing,


Zhejiang,P.R.China
Post Code:325604
http://english.delixi-electric.com

Canon Crescan Drive , Roodekop


Germiston, 1400
PO Box 13151 , Elspark, 1418
Mobile: +27 (0) 836438898
www.delixi-electric.co.za
Contact: Vicky HATTINGH
vicky@delixi-electric.co.za

20 Tsar Samuil str . , 1rst Floor


Triaditsa Municipality
Sofia
Bulgaria
Contact: Doychin ZAHARINOV
Mobile: +359 885 750 232
doychin.zaharinov@delixi-electric-see.com

Delixi Electric Middle-East

Delixi Electric West Africa

Delixi Electric Pakistan

RAK Free trade zone


PO BOX 10559
Ras El Khaima
United Arab Emirates
Tel: +971 ( 7 ) 244 47 27
Fax: + 971 ( 7 ) 244 27 22
delixi-electric.gulf@delanme.com
Contact: Raja BHAUMIK
Mobile: +971 ( 50 ) 657 1056
raja@delanme.com

1 Tunde Gaffar Close


Off Adeniyi Jones
Ikeja
Lagos
Nigeria
Fax: + 234 2703941
Contact: Chidiebere NWORGU
Mobile: +234 703 41 111 30
chidiebere.Nworgu@delixi-electric.com

73 / B / 3 , Race View,Jail Road,


Lahore, 54000,
Pakistan
Tel: 0092 - 42 - 7570412 / 7570443 ,
extension 100/103
Fax: 0092 - 42 - 7570443 , extension 108
Contact: Syed Sohail IDREES
Mobile: 0092 -3028489564
s.idrees@delixi-electric.com

Delixi Electric Marocco


213 Centre Yousra
Rond-point dEurope
Casablanca, Maroc
tel: +212 (0) 22 268 161
Fax: +212 (0) 22 491342
Contact: Hicham MOUKI
Mobile: +212 (0) 61 100 849
hmouki@delixielectric.ma

Delixi Electric South East Asia

Delixi Electric Israel

P.O.Box 7567
Pejabat Post Besar Shah Alam
40720 Shah Alam
Selangor Darul Ehsan
Tel: 03-78809564
Fax: 03-78809540
Contact: Ellis Lee
Email: ellis.lee@delixi-electric.com

Hamelacha 22 Rosh Haayin


Sibel Park, 48091
Israel
Cell: +972-546798718
Tel: +972-3-9551316
Fax: +972-3-9551317
Contact: Hayim Cohen
Email: hayim.cohen@delixi-electric.co.il

Delixi Electric Saudi Arabia

Delixi Electric Argentina

Delixi Electric Egypt

Contact: Mohkam Sheikh


Mobile: +966050269801

Contact: Damian Cattaino


Mobile: +54111545658952

Contact: Mohamed Nagy


Mobile 20(0) 100705454

Product Panorama
Power Distribution

Industry Control

Contents
MCB Miniature Circuit Breakers
CDB6a 18mm Miniature Circuit Breakers

CDB6L 18mm Miniature Circuit Breakers

CDB6N 18mm Miniature Circuit Breakers

CDB6&CDB6LE Electrical Auxiliaries

CDB17 Miniature Circuit Breakers

CDB3 Phase-neutral Circuit Breakers

10

CDB2 27mm Miniature Circuit Breakers

11

CDB5 Switch Disconnectors

13

RCBO Residual Current Operated Circuit Breakers With


Integral Overcurrent Protection
CDB6LE Electronic Type Residual Current Operated Circuit Breakers

15

CDB3LE Electronic Type Residual Current Operated Circuit Breakers

17

CDB2LE Electronic Type Residual Current Operated Circuit Breakers

18

CDB7LSP Electronic Type Residual Current Operated Circuit Breakers

20

RCCB Residual Current Operated Circuit Breakers


Without Overcurrent Protection
CDL7 Electromagnetic Type Residual Current Switches

21

Surge Protector
CDY1 Surge Protective Devices

22

MCB Distribution Board


CDPZ50 Distribution Box

25

Meter
DDS607 Single-phase Electronic Watt-hour Meters

27

MCCB Moulded Case Circuit Breakers


CDM1 Moulded Case Circuit Breakers

29

ELCB Earth-leakage Circuit Breakers


CDM1L Moulded Case Circuit Breakers With Electronic Type Residual Current
Operated Protection

36

ACB Air Circuit Breaker


CDW7 Air Circuit Breaker

42

Contactors
CDC17 AC Contactor

61

Relays
CDR17 Thermal overload relays

70

Current Transformer
LMK Current Transformer

73

Fuse
RT16 Fuse

76

RT18 Fuse

78

Power Distribution Box


JXF Power Distribution Box

80

Control Signal
LD11 Series of indicator light

82

LAY3 Serie of pushbuttons

86

LAY7 Serie of pushbuttons

88

LAY8 Serie of pushbuttons

93

Pannel Meter
72 Series Pannel Meter

96

96 Series Pannel Meter

98

Voltage Stabilizer
TND Voltage Stabilizer

100

Nylon Lock
Nylon Cable Ties Series

102

CDB6a
Standard: IEC 60898-1 IEC 60947-2
Trip Curve: B, C and D curves
Breaking Capacity: 3000A

Function

CDB6a miniature circuit breakers combine the following functions:


Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Control
Isolation

Description

Technical data
Rated current: 1, 3, 6, 10, 16, 20, 25, 32, 40, 50, 63 A
Rated voltage: 230/400V AC
Breaking capacity
Rate
current

Breaking capacity
Icn (A)

Type

Poles

Voltage
(V)

1-63A

3000

1P
2P, 3P, 4P
1P
2P, 3P, 4P
1P
2P, 3P, 4P

230
400
230
400
230
400

C
D

Tropicalization: treatment 2
Protection degree: 2
Connection:
up to 25mm2 cables
Tripping curves:
B curve: the magnetic release operates between 3 and 5 In
C curve: the magnetic release operates between 5 and 10 In
D curve: the magnetic release operates between 10 and 14 In
35 mm standard DIN rail mounting

Standard and certification


IEC 60898-1
KEMA, CB

IEC 60947-2

Overall dimensions
Unit:mm

Delixi Electric

CDB6a
Standard: IEC 60898-1 IEC 60947-2
Trip Curve: B, C and D curves
Breaking Capacity: 3000A
Type

Rating Width
(A)
(in mod.of 9mm)

Reference
B curve
C curve

D curve

1P

1
3
6
10
16
20
25
32
40
50
63
1
3
6
10
16
20
25
32
40
50
63
1
3
6
10
16
20
25
32
40
50
63
1
3
6
10
16
20
25
32
40
50
63

CDB6a1B1
CDB6a1B3
CDB6a1B6
CDB6a1B10
CDB6a1B16
CDB6a1B20
CDB6a1B25
CDB6a1B32
CDB6a1B40
CDB6a1B50
CDB6a1B63
CDB6a2B1
CDB6a2B3
CDB6a2B6
CDB6a2B10
CDB6a2B16
CDB6a2B20
CDB6a2B25
CDB6a2B32
CDB6a2B40
CDB6a2B50
CDB6a2B63
CDB6a3B1
CDB6a3B3
CDB6a3B6
CDB6a3B10
CDB6a3B16
CDB6a3B20
CDB6a3B25
CDB6a3B32
CDB6a3B40
CDB6a3B50
CDB6a3B63
CDB6a4B1
CDB6a4B3
CDB6a4B6
CDB6a4B10
CDB6a4B16
CDB6a4B20
CDB6a4B25
CDB6a4B32
CDB6a4B40
CDB6a4B50
CDB6a4B63

CDB6a1D1
CDB6a1D3
CDB6a1D6
CDB6a1D10
CDB6a1D16
CDB6a1D20
CDB6a1D25
CDB6a1D32
CDB6a1D40
CDB6a1D50
CDB6a1D63
CDB6a2D1
CDB6a2D3
CDB6a2D6
CDB6a2D10
CDB6a2D16
CDB6a2D20
CDB6a2D25
CDB6a2D32
CDB6a2D40
CDB6a2D50
CDB6a2D63
CDB6a3D1
CDB6a3D3
CDB6a3D6
CDB6a3D10
CDB6a3D16
CDB6a3D20
CDB6a3D25
CDB6a3D32
CDB6a3D40
CDB6a3D50
CDB6a3D63
CDB6a4D1
CDB6a4D3
CDB6a4D6
CDB6a4D10
CDB6a4D16
CDB6a4D20
CDB6a4D25
CDB6a4D32
CDB6a4D40
CDB6a4D50
CDB6a4D63

2P

3P

4P

2
2
2
2
2
2
2
2
2
2
2
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
8
8
8
8

CDB6a1C1
CDB6a1C3
CDB6a1C6
CDB6a1C10
CDB6a1C16
CDB6a1C20
CDB6a1C25
CDB6a1C32
CDB6a1C40
CDB6a1C50
CDB6a1C63
CDB6a2C1
CDB6a2C3
CDB6a2C6
CDB6a2C10
CDB6a2C16
CDB6a2C20
CDB6a2C25
CDB6a2C32
CDB6a2C40
CDB6a2C50
CDB6a2C63
CDB6a3C1
CDB6a3C3
CDB6a3C6
CDB6a3C10
CDB6a3C16
CDB6a3C20
CDB6a3C25
CDB6a3C32
CDB6a3C40
CDB6a3C50
CDB6a3C63
CDB6a4C1
CDB6a4C3
CDB6a4C6
CDB6a4C10
CDB6a4C16
CDB6a4C20
CDB6a4C25
CDB6a4C32
CDB6a4C40
CDB6a4C50
CDB6a4C63

Tripping Curve

Delixi Electric

CDB6L
Standard: IEC 60947-2 IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 4500A

Function

CDB6L miniature circuit breakers combine the following functions:


Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Control
Isolation

Description

Technical data
Rated current: 1, 3, 6, 10, 16, 20, 25, 32, 40, 50, 63 A
Rated voltage: 230/400V AC
Breaking capacity:
Type

Poles

Rate
current

Breaking capacity
Icn (A)

Voltage
(V)

1P

1-40A
50A, 63A
1-40A
50A, 63A
1-40A
50A, 63A
1-40A
50A, 63A
1-40A
50A, 63A
1-40A
50A, 63A

4500
4500
4500
4500
4500
4500
4500
4500
4500
4500
4500
4500

230
400
230
400
230
400
230
400
230
400
230
400

2P, 3P, 4P
C

1P
2P, 3P, 4P

1P
2P, 3P, 4P

Tropicalization: treatment 2
Protection degree: 2
Connection:
up to 25mm2 cables
Tripping curves:
B curve: the magnetic release operates between 3 and 5 In
C curve: the magnetic release operates between 5 and 10 In
D curve: the magnetic release operates between 10 and 14 In
35 mm standard DIN rail mounting

Standard and certification


IEC 60947-2 IEC 60898-1
KEMA, CB

Overall dimensions
Unit:mm

Delixi Electric

CDB6L
Standard: IEC 60947-2 IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 4500A
Type

Rating
(A)

Width
Reference
(in mod.of 9mm) B curve

1P

1
3
6
10
16
20
25
32
40
50
63
1
3
6
10
16
20
25
32
40
50
63
1
3
6
10
16
20
25
32
40
50
63
1
3
6
10
16
20
25
32
40
50
63

2
2
2
2
2
2
2
2
2
2
2
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
8
8
8
8

2P

3P

4P

C curve
CDB6L1C1
CDB6L1C3
CDB6L1C6
CDB6L1C10
CDB6L1C16
CDB6L1C20
CDB6L1C25
CDB6L1C32
CDB6L1C40
CDB6L1C50
CDB6L1C63
CDB6L2C1
CDB6L2C3
CDB6L2C6
CDB6L2C10
CDB6L2C16
CDB6L2C20
CDB6L2C25
CDB6L2C32
CDB6L2C40
CDB6L2C50
CDB6L2C63
CDB6L3C1
CDB6L3C3
CDB6L3C6
CDB6L3C10
CDB6L3C16
CDB6L3C20
CDB6L3C25
CDB6L3C32
CDB6L3C40
CDB6L3C50
CDB6L3C63
CDB6L4C1
CDB6L4C3
CDB6L4C6
CDB6L4C10
CDB6L4C16
CDB6L4C20
CDB6L4C25
CDB6L4C32
CDB6L4C40
CDB6L4C50
CDB6L4C63

CDB6L1B1
CDB6L1B3
CDB6L1B6
CDB6L1B10
CDB6L1B16
CDB6L1B20
CDB6L1B25
CDB6L1B32
CDB6L1B40
CDB6L1B50
CDB6L1B63
CDB6L2B1
CDB6L2B3
CDB6L2B6
CDB6L2B10
CDB6L2B16
CDB6L2B20
CDB6L2B25
CDB6L2B32
CDB6L2B40
CDB6L2B50
CDB6L2B63
CDB6L3B1
CDB6L3B3
CDB6L3B6
CDB6L3B10
CDB6L3B16
CDB6L3B20
CDB6L3B25
CDB6L3B32
CDB6L3B40
CDB6L3B50
CDB6L3B63
CDB6L4B1
CDB6L4B3
CDB6L4B6
CDB6L4B10
CDB6L4B16
CDB6L4B20
CDB6L4B25
CDB6L4B32
CDB6L4B40
CDB6L4B50
CDB6L4B63

D curve
CDB6L1D1
CDB6L1D3
CDB6L1D6
CDB6L1D10
CDB6L1D16
CDB6L1D20
CDB6L1D25
CDB6L1D32
CDB6L1D40
CDB6L1D50
CDB6L1D63
CDB6L2D1
CDB6L2D3
CDB6L2D6
CDB6L2D10
CDB6L2D16
CDB6L2D20
CDB6L2D25
CDB6L2D32
CDB6L2D40
CDB6L2D50
CDB6L2D63
CDB6L3D1
CDB6L3D3
CDB6L3D6
CDB6L3D10
CDB6L3D16
CDB6L3D20
CDB6L3D25
CDB6L3D32
CDB6L3D40
CDB6L3D50
CDB6L3D63
CDB6L4D1
CDB6L4D3
CDB6L4D6
CDB6L4D10
CDB6L4D16
CDB6L4D20
CDB6L4D25
CDB6L4D32
CDB6L4D40
CDB6L4D50
CDB6L4D63

Tripping Curve

Delixi Electric

CDB6N
Standard: IEC 60947-2 IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 6000A

Function

CDB6N miniature circuit breakers combine the following functions:


Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Control
Isolation

Description

Technical data
Rated current: 1, 3, 6, 10, 16, 20, 25, 32, 40, 50, 63 A
Rated voltage: 230/400V AC
Breaking capacity:
Type

Poles

Rate
current

Breaking capacity
Icn (A)

Voltage
(V)

1P

1-40A
50A, 63A
1-40A
50A, 63A
1-40A
50A, 63A
1-40A
50A, 63A
1-40A
50A, 63A
1-40A
50A, 63A

6000
4500
6000
4500
6000
4500
6000
4500
6000
4500
6000
4500

230
400
230
400
230
400
230
400
230
400
230
400

2P, 3P, 4P
C

1P
2P, 3P, 4P

1P
2P, 3P, 4P

Tropicalization: treatment 2
Protection degree: 2
Connection:
up to 25mm2 cables
Tripping curves:
B curve: the magnetic release operates between 3 and 5 In
C curve: the magnetic release operates between 5 and 10 In
D curve: the magnetic release operates between 10 and 14 In
35 mm standard DIN rail mounting

Standard and certification


IEC 60947-2 IEC 60898-1
KEMA, CB

Overall dimensions
Unit:mm

Delixi Electric

CDB6N
Standard: IEC 60947-2 IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 6000A
Type

Rating Width
Reference
(A)
(in mod.of 9mm) B curve

C curve

D curve

1P

1
3
6
10
16
20
25
32
40
50*
63*
1
3
6
10
16
20
25
32
40
50*
63*
1
3
6
10
16
20
25
32
40
50*
63*
1
3
6
10
16
20
25
32
40
50*
63*

CDB6N1C1
CDB6N1C3
CDB6N1C6
CDB6N1C10
CDB6N1C16
CDB6N1C20
CDB6N1C25
CDB6N1C32
CDB6N1C40
CDB6N1C50
CDB6N1C63
CDB6N2C1
CDB6N2C3
CDB6N2C6
CDB6N2C10
CDB6N2C16
CDB6N2C20
CDB6N2C25
CDB6N2C32
CDB6N2C40
CDB6N2C50
CDB6N2C63
CDB6N3C1
CDB6N3C3
CDB6N3C6
CDB6N3C10
CDB6N3C16
CDB6N3C20
CDB6N3C25
CDB6N3C32
CDB6N3C40
CDB6N3C50
CDB6N3C63
CDB6N4C1
CDB6N4C3
CDB6N4C6
CDB6N4C10
CDB6N4C16
CDB6N4C20
CDB6N4C25
CDB6N4C32
CDB6N4C40
CDB6N4C50
CDB6N4C63

CDB6N1D1
CDB6N1D3
CDB6N1D6
CDB6N1D10
CDB6N1D16
CDB6N1D20
CDB6N1D25
CDB6N1D32
CDB6N1D40
CDB6N1D50
CDB6N1D63
CDB6N2D1
CDB6N2D3
CDB6N2D6
CDB6N2D10
CDB6N2D16
CDB6N2D20
CDB6N2D25
CDB6N2D32
CDB6N2D40
CDB6N2D50
CDB6N2D63
CDB6N3D1
CDB6N3D3
CDB6N3D6
CDB6N3D10
CDB6N3D16
CDB6N3D20
CDB6N3D25
CDB6N3D32
CDB6N3D40
CDB6N3D50
CDB6N3D63
CDB6N4D1
CDB6N4D3
CDB6N4D6
CDB6N4D10
CDB6N4D16
CDB6N4D20
CDB6N4D25
CDB6N4D32
CDB6N4D40
CDB6N4D50
CDB6N4D63

2P

3P

4P

2
2
2
2
2
2
2
2
2
2
2
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
8
8
8
8

CDB6N1B1
CDB6N1B3
CDB6N1B6
CDB6N1B10
CDB6N1B16
CDB6N1B20
CDB6N1B25
CDB6N1B32
CDB6N1B40
CDB6N1B50
CDB6N1B63
CDB6N2B1
CDB6N2B3
CDB6N2B6
CDB6N2B10
CDB6N2B16
CDB6N2B20
CDB6N2B25
CDB6N2B32
CDB6N2B40
CDB6N2B50
CDB6N2B63
CDB6N3B1
CDB6N3B3
CDB6N3B6
CDB6N3B10
CDB6N3B16
CDB6N3B20
CDB6N3B25
CDB6N3B32
CDB6N3B40
CDB6N3B50
CDB6N3B63
CDB6N4B1
CDB6N4B3
CDB6N4B6
CDB6N4B10
CDB6N4B16
CDB6N4B20
CDB6N4B25
CDB6N4B32
CDB6N4B40
CDB6N4B50
CDB6N4B63

Tripping Curve

Delixi Electric

CDB6&CDB6LE Electrical Auxiliaries

Type

Voltage

Reference

OF

AC230

CDB6OF230AC

AC400

CDB6OF400AC

DC24

CDB6OF24DC

DC48

CDB6OF48DC

DC110

CDB6OF110DC

DC220

CDB6OF220DC

AC230

CDB6SD230AC

AC400

CDB6SD400AC

DC24

CDB6SD24DC

DC48

CDB6SD48DC

DC110

CDB6SD110DC

DC220

CDB6SD220DC

AC230

CDB6MX230AC

DC24

CDB6MX24AC

SD

MX+OF*

OF contact auxiliary

SD fault-indicating switch

MX+OF shunt trip release

Delixi Electric

CDB17
Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 6000A

Function

CDB17N miniature circuit breakers combine the following functions:


Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Control
Isolation

Description

Technical data
Rated current: 1, 3, 6, 10, 16, 20, 25, 32, 40, 50, 63 A
Rated voltage: 230/400V AC
Breaking capacity
Rate
current

Breaking capacity
Icn (A)

Type

Poles

Voltage
(V)

1-63A

6000

1P
2P,3P,4P
1P
2P,3P,4P
1P
2P,3P,4P

230
400
230
400
230
400

C
D

Tropicalization: treatment 2
Protection degree: 2
Connection:
up to 25mm 2 cables
Tripping curves:
B curve: the magnetic release operates between 3 and 5 In
C curve: the magnetic release operates between 5 and 10 In
D curve: the magnetic release operates between 10 and 14 In
35 mm standard DIN rail mounting

Standard and certification


IEC 60898-1
KEMA, CB, CE

Overall dimensions
Unit:mm

Delixi Electric

CDB17
Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 6000A
Type

Rating
(A)

Width
Reference
(in mod.of 9mm) B curve

1P

1
3
6
10
16
20
25
32
40
50
63
1
3
6
10
16
20
25
32
40
50
63
1
3
6
10
16
20
25
32
40
50
63
1
3
6
10
16
20
25
32
40
50
63

2
2
2
2
2
2
2
2
2
2
2
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
8
8
8
8

2P

3P

4P

C curve
CDB17N1C1
CDB17N1C3
CDB17N1C6
CDB17N1C10
CDB17N1C16
CDB17N1C20
CDB17N1C25
CDB17N1C32
CDB17N1C40
CDB17N1C50
CDB17N1C63
CDB17N2C1
CDB17N2C3
CDB17N2C6
CDB17N2C10
CDB17N2C16
CDB17N2C20
CDB17N2C25
CDB17N2C32
CDB17N2C40
CDB17N2C50
CDB17N2C63
CDB17N3C1
CDB17N3C3
CDB17N3C6
CDB17N3C10
CDB17N3C16
CDB17N3C20
CDB17N3C25
CDB17N3C32
CDB17N3C40
CDB17N3C50
CDB17N3C63
CDB17N4C1
CDB17N4C3
CDB17N4C6
CDB17N4C10
CDB17N4C16
CDB17N4C20
CDB17N4C25
CDB17N4C32
CDB17N4C40
CDB17N4C50
CDB17N4C63

CDB17N1B1
CDB17N1B3
CDB17N1B6
CDB17N1B10
CDB17N1B16
CDB17N1B20
CDB17N1B25
CDB17N1B32
CDB17N1B40
CDB17N1B50
CDB17N1B63
CDB17N2B1
CDB17N2B3
CDB17N2B6
CDB17N2B10
CDB17N2B16
CDB17N2B20
CDB17N2B25
CDB17N2B32
CDB17N2B40
CDB17N2B50
CDB17N2B63
CDB17N3B1
CDB17N3B3
CDB17N3B6
CDB17N3B10
CDB17N3B16
CDB17N3B20
CDB17N3B25
CDB17N3B32
CDB17N3B40
CDB17N3B50
CDB17N3B63
CDB17N4B1
CDB17N4B3
CDB17N4B6
CDB17N4B10
CDB17N4B16
CDB17N4B20
CDB17N4B25
CDB17N4B32
CDB17N4B40
CDB17N4B50
CDB17N4B63

D curve
CDB17N1D1
CDB17N1D3
CDB17N1D6
CDB17N1D10
CDB17N1D16
CDB17N1D20
CDB17N1D25
CDB17N1D32
CDB17N1D40
CDB17N1D50
CDB17N1D63
CDB17N2D1
CDB17N2D3
CDB17N2D6
CDB17N2D10
CDB17N2D16
CDB17N2D20
CDB17N2D25
CDB17N2D32
CDB17N2D40
CDB17N2D50
CDB17N2D63
CDB17N3D1
CDB17N3D3
CDB17N3D6
CDB17N3D10
CDB17N3D16
CDB17N3D20
CDB17N3D25
CDB17N3D32
CDB17N3D40
CDB17N3D50
CDB17N3D63
CDB17N4D1
CDB17N4D3
CDB17N4D6
CDB17N4D10
CDB17N4D16
CDB17N4D20
CDB17N4D25
CDB17N4D32
CDB17N4D40
CDB17N4D50
CDB17N4D63

Tripping Curve

Delixi Electric

CDB3
Standard: IEC 60898-1
Trip Curve: C and D curves
Breaking Capacity: 3000A

Function

CDB3 phase-neutral circuit breakers combine the following functions:


Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Control
Isolation

Description

Technical data
Rated current: 6, 10, 16, 20, 25, 32A
Rated voltage: 230V AC
Breaking capacity: 3 kA
Tripping curves:
C curve: the magnetic release operates between 5 and 10 In
D curve: the magnetic release operates between 10 and 14 In
Tropicalization: treatment 2
Protection degree: 2
Connection
Up to 16mm2 cables
35mm standard DIN rail mounting

Standard and certification


IEC 60898-1
Type

Rating
(A)

Width
(in mod.of 9mm)

Reference
C curve

D curve

1P+N

6
10
16
20
25
32

2
2
2
2
2
2

CDB3a5C6
CDB3a5C10
CDB3a5C16
CDB3a5C20
CDB3a5C25
CDB3a5C32

CDB3a5D6
CDB3a5D10
CDB3a5D16
CDB3a5D20
CDB3a5D25
CDB3a5D32

Overall dimensions

Tripping Curve

10

Delixi Electric

CDB2
Standard: IEC 60947-2
Trip Curve: C and D curves
Breaking Capacity: 10000A

Function

CDB2 miniature circuit breakers combine the following functions:


Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Control
Isolation

Description

Technical data
Rated current: 63, 80, 100, 125 A
Rated voltage : 230/400V AC
Breaking capacity
Rating
(A)

Type

Voltage
(V)

Breaking capacity
(kA)

63 ~125

1P
2/3/4P

230
400

10
10

Tripping curves:
C curve: the magnetic release operates between 5 and 10 In
D curve: the magnetic release operates between 10 and 14 In
Mechanical durability: 8,500 (In 100A) / 7,000 (In=125A)
Electrical durability: 1,500 (In 100A) / 1,000 (In=125A)
Tropicalization: treatment 2
Protection degree: 2
Connection
Up to 50 mm 2 cables
35mm standard DIN rail mounting
Closed position indication

Standard and certification


IEC 60947-2
SEMKO, CE

Overall dimensions
Unit:mm

Delixi Electric

11

CDB2
Standard: IEC 60947-2
Trip Curve: C and D curves
Breaking Capacity: 10000A
Type

Rating
(A)

Width
(in mod.of 9mm)

Reference
C curve

D curve

1P

63
80
100
125

3
3
3
3

CDB2H1C63
CDB2H1C80
CDB2H1C100
CDB2H1C125

CDB2H1D63
CDB2H1D80
CDB2H1D100
CDB2H1D125

2P

63
80
100
125

6
6
6
6

CDB2H2C63
CDB2H2C80
CDB2H2C100
CDB2H2C125

CDB2H2D63
CDB2H2D80
CDB2H2D100
CDB2H2D125

3P

63
80
100
125

9
9
9
9

CDB2H3C63
CDB2H3C80
CDB2H3C100
CDB2H3C125

CDB2H3D63
CDB2H3D80
CDB2H3D100
CDB2H3D125

4P

63
80
100
125

12
12
12
12

CDB2H4C63
CDB2H4C80
CDB2H4C100
CDB2H4C125

CDB2H4D63
CDB2H4D80
CDB2H4D100
CDB2H4D125

Tripping Curve

12

Delixi Electric

CDB5
Standard: IEC 60947-3

Function

CDB5 switch disconnectors combine the following functions:


Making and breaking normal load circuits
Isolation

Description

Technical data
Rated current: 20, 32, 63, 100 A
Rated voltage: 230/400V AC
Mechanical durability: 8500
Electrical durability: 1500
Short-time withstand capacity for 1 s: 12Ie
Tropicalization: treatment 2
Protection degree: 2
Connection
Up to 35 mm2 cables
35 mm standard DIN rail mounting
Isolation with positive break indication

Standard and certification


IEC 60947-3

Overall dimensions
Unit:mm

Delixi Electric

13

CDB5
Standard: IEC 60947-3

14

Type

Rating
(A)

Voltage
(V AC)

Width
(in mod.of 9mm)

Reference

1P

20
32
63
100

230
230
230
230

2
2
2
2

CDB5120
CDB5132
CDB5163
CDB51100

2P

20
32
63
100

400
400
400
400

4
4
4
4

CDB5220
CDB5232
CDB5263
CDB52100

3P

20
32
63
100

400
400
400
400

6
6
6
6

CDB5320
CDB5332
CDB5363
CDB53100

4P

20
32
63
100

400
400
400
400

8
8
8
8

CDB5420
CDB5432
CDB5463
CDB54100

Delixi Electric

CDB6LE
Standard: IEC 61009
Trip Curve: C and D curves
Breaking Capacity: 3000A
Sensitivity: 30mA

Function

CDB6LE electronic type residual current operated circuit breakers combine the following functions:
Overload protection
Protection against short-circuit current
Protection for users against indirect contact
Additional protection for users against direct contacts (30mA)
Protection for electrical installations against insulation faults (fire hazard, etc)
Isolation

Description

Technical data
Rated current: 6, 10, 16, 20, 25, 32, 40, 50, 60A
Rated voltage: 230V AC for 1P+N/2P, 400V AC for 3P/3P+N/4P
Sensitivity: 30 mA
Tropicalization: treatment 2
Protection degree: 2
Connection
Up to 16 mm2 cables
Tripping curves:
C curve: the magnetic release operates between 5 and 10 In
D curve: the magnetic release operates between 10 and 14 In
Mechanical indication of the earth fault on the front face by a black mechanical
indicator
35 mm standard DIN rail mounting.

Standard and certification


IEC 61009

Overall dimensions

CDB6LE-32

CDB6LE-63

Delixi Electric

15

CDB6LE
Standard: IEC 61009
Trip Curve: C and D curves
Breaking Capacity: 3000A
Sensitivity: 30mA
Type

Voltage
(V)

Sensitivity Rating
(mA)
(A)

1P+N

230

30

2P

230

30

3P

400

30

3P+N

400

30

4P

400

30

6
10
16
20
25
32
40
50
60
6
10
16
20
25
32
40
50
60
6
10
16
20
25
32
40
50
60
6
10
16
20
25
32
40
50
60
6
10
16
20
25
32
40
50
60

Width
Reference
(in mod.of 9mm) C curve
5
5
5
5
5
5
6
6
6
7
7
7
7
7
7
8
8
8
10
10
10
10
10
10
12
12
12
11
11
11
11
11
11
14
14
14
13
13
13
13
13
13
16
16
16

CDB6LEa1C6S
CDB6LLEa1C10S
CDB6LEa1C16S
CDB6LEa1C20S
CDB6LEa1C25S
CDB6LEa1C32S
CDB6LEa1C40S
CDB6LEa1C50S
CDB6LEa1C60S
CDB6LEa2C6S
CDB6LEa2C10S
CDB6LEa2C16S
CDB6LEa2C20S
CDB6LEa2C25S
CDB6LEa2C32S
CDB6LEa2C40S
CDB6LEa2C50S
CDB6LEa2C60S
CDB6LEa3C6S
CDB6LEa3C10S
CDB6LEa3C16S
CDB6LEa3C20S
CDB6LEa3C25S
CDB6LEa3C32S
CDB6LEa3C40S
CDB6LEa3C50S
CDB6LEa3C60S
CDB6LEa4C6S
CDB6LEa4C10S
CDB6LEa4C16S
CDB6LEa4C20S
CDB6LEa4C25S
CDB6LEa4C32S
CDB6LEa4C40S
CDB6LEa4C50S
CDB6LEa4C60S
CDB6LEa6C6S
CDB6LEa6C10S
CDB6LEa6C16S
CDB6LEa6C20S
CDB6LEa6C25S
CDB6LEa6C32S
CDB6LEa6C40S
CDB6LEa6C50S
CDB6LEa6C60S

D curve
CDB6LEa1D6S
CDB6LEa1D10S
CDB6LEa1D16S
CDB6LEa1D20S
CDB6LEa1D25S
CDB6LEa1D32S
CDB6LEa1D40S
CDB6LEa1D50S
CDB6LEa1D60S
CDB6LEa2D6S
CDB6LEa2D10S
CDB6LEa2D16S
CDB6LEa2D20S
CDB6LEa2D25S
CDB6LEa2D32S
CDB6LEa2D40S
CDB6LEa2D50S
CDB6LEa2D60S
CDB6LEa3D6S
CDB6LEa3D10S
CDB6LEa3D16S
CDB6LEa3D20S
CDB6LEa3D25S
CDB6LEa3D32S
CDB6LEa3D40S
CDB6LEa3D50S
CDB6LEa3D60S
CDB6LEa4D6S
CDB6LEa4D10S
CDB6LEa4D16S
CDB6LEa4D20S
CDB6LEa4D25S
CDB6LEa4D32S
CDB6LEa4D40S
CDB6LEa4D50S
CDB6LEa4D60S
CDB6LEa6D6S
CDB6LEa6D10S
CDB6LEa6D16S
CDB6LEa6D20S
CDB6LEa6D25S
CDB6LEa6D32S
CDB6LEa6D40S
CDB6LEa6D50S
CDB6LEa6D60S

Tripping Curve

16

Delixi Electric

CDB3LE
Standard: IEC 61009
Trip Curve: C curves
Breaking Capacity: 3000A
Sensitivity: 30mA

Function

CDB3LE electronic type residual current operated circuit breakers combine the following functions:
Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Protection of users against indirect contact
Additional protection for users against direct contacts (30mA)
Protection of electrical installations against insulation faults (fire hazard, etc)
Isolation

Description

Technical data
Rated current: 6, 10, 16, 20, 25, 32, 40A
Rated voltage: 230V AC
Breaking capacity: 3kA
Sensitivity: 30mA
Tripping curve:
C curve: the magnetic release operates between 5 and 10 In
Tropicalization: treatment 2
Protection degree: 2
Connection
Up to 6 mm2 cables
Mechanical indication of the earth fault on the front face by a red mechanical indicator
35 mm standard DIN rail mounting

Standard and certification


IEC 61009
Type

Sensltivity(mA) Width (in mod.of 9mm)


4

1P+N 30

Rating(A)

Reference C curve

6
10
16
20
25
32
40

CDB3LEa5C6S
CDB3LEa5C10S
CDB3LEa5C16S
CDB3LEa5C20S
CDB3LEa5C25S
CDB3LEa5C32S
CDB3LEa5C40S

Overall dimensions
Unit:mm

Tripping Curve

Delixi Electric

17

CDB2LE
Standard: IEC 60947-2
Trip Curve: C and D curves
Breaking Capacity: 10000A
Sensitivity: 100mA, 300mA

Function

CDB2LE electronic type residual current operated circuit breakers combine the following functions:
Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Protection of users against indirect contact
Protection of electrical installations against insulation faults (fire hazard, etc)
Isolation

Description

Technical data
Rated current: 63A, 80A,100A
Rated voltage: 230V for 1P+N; 400V for 2P/3P/3P+N/4P
Sensitivity: 100mA,300mA
Rated ultimate short-circuit breaking capacity (Icu): 10,000A
Rated service short-circuit breaking capacity (Ics): 7,500A
Tripping curves:
C curve: the magnetic release operates between 5 and 10 In
D curve: the magnetic release operates between 10 and 14 In
2 types of residual current tripping are available:
Instantaneous
Time-delay with a maximum delay time of 0.2 s
Tropicalization: treatment 2
Protection degree: 2
Connection
Up to 50 mm2 cables
Mechanical indication of the earth fault on the front face by a black mechanical
indicator
Closed position indication
35 mm standard DIN rail mounting

Standard and certification


IEC 60947-2

Overall dimensions
Unit:mm

18

Delixi Electric

CDB2LE
Standard: IEC 60947-2
Trip Curve: C and D curves
Breaking Capacity: 10000A
Sensitivity: 100mA, 300mA
Type

Width
Sensitivity Rating
(in mod.of 9mm) (mA)
(A)

Reference
C curve

D curve

1P+N 6

100
100
100
300
300
300

63
80
100
63
80
100

CDB2LEH1C63Y
CDB2LEH1C80Y
CDB2LEH1C100Y
CDB2LEH1C63T
CDB2LEH1C80T
CDB2LEH1C100T

CDB2LEH1D63Y
CDB2LEH1D80Y
CDB2LEH1D100Y
CDB2LEH1D63T
CDB2LEH1D80T
CDB2LEH1D100T

2P

100
100
100
300
300
300

63
80
100
63
80
100

CDB2LEH2C63Y
CDB2LEH2C80Y
CDB2LEH2C100Y
CDB2LEH2C63T
CDB2LEH2C80T
CDB2LEH2C100T

CDB2LEH2D63Y
CDB2LEH2D80Y
CDB2LEH2D100Y
CDB2LEH2D63T
CDB2LEH2D80T
CDB2LEH2D100T

3P

12

100
100
100
300
300
300

63
80
100
63
80
100

CDB2LEH3C63Y
CDB2LEH3C80Y
CDB2LEH3C100Y
CDB2LEH3C63T
CDB2LEH3C80T
CDB2LEH3C100T

CDB2LEH3D63Y
CDB2LEH3D80Y
CDB2LEH3D100Y
CDB2LEH3D63T
CDB2LEH3D80T
CDB2LEH3D100T

3P+N 12

100
100
100
300
300
300

63
80
100
63
80
100

CDB2LEH6C63Y
CDB2LEH6C80Y
CDB2LEH6C100Y
CDB2LEH6C63T
CDB2LEH6C80T
CDB2LEH6C100T

CDB2LEH6D63Y
CDB2LEH6D80Y
CDB2LEH6D100Y
CDB2LEH6D63T
CDB2LEH6D80T
CDB2LEH6D100T

4P

100
100
100
300
300
300

63
80
100
63
80
100

CDB2LEH4C63Y
CDB2LEH4C80Y
CDB2LEH4C100Y
CDB2LEH4C63T
CDB2LEH4C80T
CDB2LEH4C100T

CDB2LEH4D63Y
CDB2LEH4D80Y
CDB2LEH4D100Y
CDB2LEH4D63T
CDB2LEH4D80T
CDB2LEH4D100T

15

Tripping Curve

Delixi Electric

19

CDB7LSP
Standard: IEC 61009
Trip Curve: C and D curves
Breaking Capacity: 6000A
Sensitivity:30mA

Function

CDB7LSP electronic type residual current operated circuit breakers combine the
following functions:
Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Protection of users against indirect contact
Additional protection for users against direct contacts (30mA)
Protection of electrical installations against insulation faults (fire hazard, etc)

Description

Technical data
Rated current: 6, 10, 16, 20, 25, 32, 40A
Rated voltage: 230V AC
Breaking capacity: 6kA
Sensitivity: 30mA
Tripping curve:
B curve: the magnetic release operates between 3 and 5 In
C curve: the magnetic release operates between 5 and 10 In
D curve: the magnetic release operates between 10 and 14 In
Tropicalization: treatment 2
Protection degree: 2
Connection
Up to 10 mm2 cables
Mechanical indication of the earth fault on the front face by a red mechanical
indicator 35 mm standard DIN rail mounting

Standard and certification


IEC 61009

Type Voltage Sensitivity Rating Width Reference


(V)
(mA)
(A)
(mm) B curve
1P+N 230

30

6
10
16
20
25
32
40

18
18
18
18
18
18
18

CDB7LSPN1B6S
CDB7LSPN1B10S
CDB7LSPN1B16S
CDB7LSPN1B20S
CDB7LSPN1B25S
CDB7LSPN1B32S
CDB7LSPN1B40S

C curve

D curve

CDB7LSPN1C6S
CDB7LSPN1C10S
CDB7LSPN1C16S
CDB7LSPN1C20S
CDB7LSPN1C25S
CDB7LSPN1C32S
CDB7LSPN1C40S

CDB7LSPN1D6S
CDB7LSPN1D10S
CDB7LSPN1D16S
CDB7LSPN1D20S
CDB7LSPN1D25S
CDB7LSPN1D32S
CDB7LSPN1D40S

Overall dimensions

20

Delixi Electric

CDL7
Standard:IEC 61008
Sensitivity: 10mA, 30mA, 100mA, 300mA
RCCB: Type A , Type AC

Function

CDL7 electromagnetic type residual current switch combine the following functions:
Protection for users against indirect contact
Additional protection for users against direct contacts (30mA)
Protection for electrical installations against insulation faults (fire hazard, etc)
Isolation

Description

Technical data
Rated current: 25, 40, 63, 80, 100A
Rated voltage: 230/400V AC
Sensitivity: 10mA, 30mA, 100mA, 300mA
Mechanical durability: 2000
Electrical durability: 1000
Tropicalization: treatment 2
Protection degree: 2
Connection
Tunnel terminals
Up to 16 mm2 cables
Type A or type AC RCCB, without overload or short-circuit protection
Dont need any auxiliary supply source.
Instantaneous earth fault trip, unadjustable
Mechanical indication of the earth fault on the front face by a red mechanical
indicator
35 mm standard DIN rail mounting

Standard and certification


IEC 61008
KEMA, CB

Overall dimensions
Unit:mm

Delixi Electric

21

CDL7
Standard:IEC 61008
Sensitivity: 10mA, 30mA, 100mA, 300mA
RCCB: Type A , Type AC

22

Type

Width
(in mod.of 9mm)

Rating Sensitivity
(A)
(mA)

Reference
A type

AC type

2P

25
25
40
63
80
100
25
40
63
80
100
25
40
63
80
100
63
80
100
63
80
100

10
30
30
30
30
30
100
100
100
100
100
300
300
300
300
300
100
100
100
300
300
300

CDL7225LA
CDL7225SA
CDL7240SA
CDL7263SA
CDL7280SA
CDL72100SA
CDL7225YA
CDL7240YA
CDL7263YA
CDL7280YA
CDL72100YA
CDL7225TA
CDL7240TA
CDL7263TA
CDL7280TA
CDL72100TA
CDL7263YAS
CDL7280YAS
CDL72100YAS
CDL7263TAS
CDL7280TAS
CDL72100TAS

CDL7225LC
CDL7225SC
CDL7240SC
CDL7263SC
CDL7280SC
CDL72100SC
CDL7225YC
CDL7240YC
CDL7263YC
CDL7280YC
CDL72100YC
CDL7225TC
CDL7240TC
CDL7263TC
CDL7280TC
CDL72100TC
CDL7263YCS
CDL7280YCS
CDL72100YCS
CDL7263TCS
CDL7280TCS
CDL72100TCS

4P

25
25
40
63
80
100
25
40
63
80
100
25
40
63
80
100
63
80
100
63
80
100

10
30
30
30
30
30
100
100
100
100
100
300
300
300
300
300
100
100
100
300
300
300

CDL7425LA
CDL7425SA
CDL7440SA
CDL7463SA
CDL7480SA
CDL74100SA
CDL7425YA
CDL7440YA
CDL7463YA
CDL7480YA
CDL74100YA
CDL7425TA
CDL7440TA
CDL7463TA
CDL7480TA
CDL74100TA
CDL7463YAS
CDL7480YAS
CDL74100YAS
CDL7463TAS
CDL7480TAS
CDL74100TAS

CDL7425LC
CDL7425SC
CDL7440SC
CDL7463SC
CDL7480SC
CDL74100SC
CDL7425YC
CDL7440YC
CDL7463YC
CDL7480YC
CDL74100YC
CDL7425TC
CDL7440TC
CDL7463TC
CDL7480TC
CDL74100TC
CDL7463YCS
CDL7480YCS
CDL74100YCS
CDL7463TCS
CDL7480TCS
CDL74100TCS

Delixi Electric

CDY1 Surge Protective Devices


Standard: IEC61643-1

Function

CDY1 surge protective devices provide:


Applicable to household appliances and the like to offer protection
When there is an over-voltage caused by either lightning strike or operation in the
circuit

Description

Technical data
Type
Pole
Nominal discharge current
In(8/20us) kA
Maximum discharge
current Imax(8/20us) kA
Maximum continuous
operational voltage Uc V
Protection level Up kV
Leakage cur rent
(75%Uc 1mA) uA
Response time ns

CDY1-10 CDY1-20 CDY1-40 CDY1-60

CDY1-80

CDY1-100 CDY1-120

1P+N, 2P
5

1P, 1P+N, 2P, 3P, 3P+N, 4P


10
20
30
40

50

60

10

20

100

120

275
1.3

40

60

80

320

275 385 420 275 385 420 275 385 420 275 385 420 275 385 420 275 385 420

1.3

1.3 1.5 1.8 1.5 1.8 2 2 2.2 2.5 2 2.2 2.2 2.2 2.5 2.5 2.2 2.5 2.5

20
25

Standard and certification


IEC61643-1

Overall dimensions

CDY1-10

CDY1-20 40 60

CDY1-80 100 120

Delixi Electric

23

CDY1 Surge Protective Devices


Standard: IEC61643-1

Imax

Pole

Refernce

10KA

1P+N

CDY1105

10KA

2P

CDY1102

20KA

1P

CDY1201

20KA

2P

CDY1202

20KA

3P

CDY1203

20KA

4P

CDY1204

20KA

1P+N

CDY1205

20KA

3P+N

CDY1206

40KA

1P

CDY1401

40KA

2P

CDY1402

40KA

3P

CDY1403

40KA

4P

CDY1404

40KA

1P+N

CDY1405

40KA

3P+N

CDY1406

60KA

1P

CDY1601

60KA

2P

CDY1602

60KA

3P

CDY1603

60KA

4P

CDY1604

60KA

1P+N

CDY1605

60KA

3P+N

CDY1606

80KA

1P

CDY1801

80KA

2P

CDY1802

80KA

3P

CDY1803

80KA

4P

CDY1804

80KA

1P+N

CDY1805

80KA

3P+N

CDY1806

100KA

1P

CDY11001

100KA

2P

CDY11002

100KA

3P

CDY11003

100KA

4P

CDY11004

100KA

1P+N

CDY11005

100KA

3P+N

CDY11006

120KA

1P

CDY11201

120KA

2P

CDY11202

120KA

3P

CDY11203

120KA

4P

CDY11204

120KA

1P+N

CDY11205

120KA

3P+N

CDY11206

20KA

Phase modle

CDY120PM

40KA

Phase modle

CDY140PM

60KA

Phase modle

CDY160PM

60KA

N-PE

CDY160NP

80KA

N-PE

CDY180NP

100KA

N-PE

CDY1100NP

120KA

N-PE

CDY1120NP

Note:"

Uc

24

" express Maximum continuous operational voltage (Uc) code

275V
275

320V
320

385V
385

420V
420

Delixi Electric

CDPZ50
Standard: IEC60439-1 IEC60670

Function

CDPZ50 distribution box provides illumination devices, sockets and electrical appliances with functions as follows:
Protection against overload
Protection against over voltage
Protection against leakage

Description

Technical data
Rated operational voltage
Maximum rated current
Rated insulation voltage
Rated frequency
Degree of protection
Instantaneous withstand current

AC 400V or AC 230V
100A
500V
50Hz/60Hz
IP30
6KA

Construction feature
Holistic steel-plastic construction
Free assembly of components
Beautiful design
Flame retardant industrial plastic in panel
The whole panel can move vertically

Standard and certification


IEC60439-1 IEC60670

Type

The amount of unit loop*

Reference

Surface installation

CDPZ50M6

CDPZ50M8

12

CDPZ50M12

16

CDPZ50M16

20

CDPZ50M20

24

CDPZ50M24

CDPZ50R6

CDPZ50R8

12

CDPZ50R12

16

CDPZ50R16

20

CDPZ50R20

24

CDPZ50R24

Flush installation

*:18mm for one unit loop

Delixi Electric

25

CDPZ50
Standard: IEC60439-1 IEC60670

Overall dimension
Unit:mm

Surface installation
Loop number

Flush installation

Surface installation

Flush installation

Thickness

171

220

163

220

90

207

220

199

220

90

12

279

220

279

220

90

16

351

220

343

220

90

20

423

220

413

220

90

24*

364

303

383

282

90

*:two rows product

26

Delixi Electric

DDS607 Single-phase Electronic Watt-hour Meter


Standard:IEC 620531-21:2003

Function

DDS607 single-phase electronic watt-hour meter provide:


Measuring energy in household and commercial single-phase network services

Description

Technical Data
Accuracy class: 1.0, 2.0
Reference voltage:220V
Current specification:1.5(6)A,3(6)A,2.5(10)A,5(20)A,5(30)A
10(40)A,15(60)A,20(80)A,30(100)A
Power:
2W/10VA (voltage circuit), 4VA(Current circuit)
Two-way measurement function: Being able to accurately measure, antitwodirections of power and
the total electricityconsumption in one direction
Extended functions: Optional liquid crystal display, infrared communications and 485
communications
Normal work temperature:-10-~+45
Limit working temperature:-25-~+55
Normal work voltage:0.9~1.1 Reference voltage
Limit work voltage:0.7~1.2 Reference voltage
Relative Humidity: 85%
Installation conditions:Meter should be installed in indoor drying, ventilation, fire-resistant, solid
walls height of 1.8 m about the use of non-corrosive gases in the nvironment,
should be moisture-proof.
Lightning request:Thunderstorms in more places should be installed in the
installation of lightning equipment

Standard and Certification


IEC620531-21:2003
KEMA

Overall dimensions

Single-phase Type A,C Meter

Delixi Electric

Single-phase LCD Meter

27

DDS607 Single-phase Electronic Watt-hour Meter


Standard:IEC 620531-21:2003

Ordering informationn
Function Description

Current
specification

Reference

Type A (Import chip)

1.5(6)A

DDS607N16M4A

Type A (Import chip)

2.5(10)A

DDS607N110M4A

Type A (Import chip)

5(20)A

DDS607N120M4A

Type A (Import chip)

5(30)A

DDS607N130M6A

Type A (Import chip)

10(40)A

DDS607N140M4A

Type A (Import chip)

15(60)A

DDS607N160M4A

Type A (Import chip)

20(80)A

DDS607N180M4A

Type A (Import chip)

30(100)A

DDS607N1100M3A

Type C (Domestic chip)

1.5(6)A

DDS607N26M4A

Type C (Domestic chip)

2.5(10)A

DDS607N210M4C

Type C (Domestic chip)

5(20)A

DDS607N220M4C

Type C (Domestic chip)

5(30)A

DDS607N230M6C

Type C (Domestic chip)

10(40)A

DDS607N240M4C

Type C (Domestic chip)

15(60)A

DDS607N260M4C

Type C (Domestic chip)

20(80)A

DDS607N280M4C

Type C (Domestic chip)

30(100)A

DDS607N2100M3C

LCD without 485 communications

1.5(6)A

DDS607N16M4CD

LCD without 485 communications

2.5(10)A

DDS607N110M4CD

LCD without 485 communications

5(20)A

DDS607N120M4CD

LCD without 485 communications

5(30)A

DDS607N130M6CD

LCD without 485 communications

10(40)A

DDS607N140M4CD

LCD without 485 communications

15(60)A

DDS607N160M4CD

LCD without 485 communications

20(80)A

DDS607N180M4CD

LCD with 485 communications

1.5(6)A

DDS607N16M4CD485

LCD with 485 communications

5(20)A

DDS607N120M4CD485

LCD with 485 communications

10(40)A

DDS607N140M4CD485

LCD with 485 communications

15(60)A

DDS607N160M4CD485

LCD with 485 communications and infrared communications 1.5(6)A

DDS607N116M4CD485I

LCD with 485 communications and infrared communications 2.5(10)A

DDS607N110M4CD485I

LCD with 485 communications and infrared communications 5(20)A

DDS607N120M4CD485I

LCD with 485 communications and infrared communications 5(30)A

DDS607N130M6CD485I

LCD with 485 communications and infrared communications 10(40)A

DDS607N140M4CD485I

LCD with 485 communications and infrared communications 15(60)A

DDS607N160M4CD485I

LCD with 485 communications and infrared communications 20(80)A

DDS607N180M4CD485I

LCD with 485 communications and infrared communications 30(100)A

DDS607N1100M3CD485I

Note: Users need special specifications can be customized

28

Delixi Electric

CDM1
Standard: IEC 60947-2

Function

CDM1 molded case circuit breakers can be used to provide the following functions:
To distribute electric power and protect circuits and equipment against overload,
undervoltage, and short-circuit faults
To protect motors against overload, undervoltage and short-circuit faults (Inm400A)
To infrequently start and control AC motors

Description

Technical data
Main technical parameters are shown in the table below
Type
Frame size rated
current A
Number of poles
Rated frequency Hz
Rated current In A

CDM1-63 CDM1-100 CDM1-225 CDM1-400 CDM1-630 CDM1-800 CDM1-1250


63
100
225
400
630
800
1250

Rated insulation
voltage Ui V
Rated impulse
withstand
voltage Uimp V
Rated operational
voltage Ue V
Icu kA Type M
(400V) Type L
Ics kA Type M
(400V) Type L
Arcing distance mm
Durability Cycles/h
Electrical
Mechanical
Power consu- Fixed
mpution W Plug-in

690V

3P,4P
50
10 16
20 25
32 40
50 63

2P,3P,4P

3P,4P

3P

16 20 100 125 200 350 400 500 400 500 700 800
25 30 160 180 250 315 630
630 700 1000
32 40 200 225 400
800
1250
50 63
80 100
800V

6000V 8000V

400V

400V / 690V

400V

50
25
30
18
50
120
4000
6000
25
30

50
35
30
26

50
35
30
26

120
3000
7000
40
50

120
1500
6500
60
75

70
50
40
30
100
60
1000
4000
40
110

400V
690V
65
45
42
34

400V
70
50
40
30

85
45
-

60
1000
4000
150
200

20
500
2500
135
190

20
500
2500
240
300

Constructional features
Thermamagnetic release offers instantaneous trip against short-circuit and long
time delay trip against overcurrent
The circuit breaker can be of fixed type or plug-in type
For 4-pole circuit breakers:
N-pole without overcurrent release, it switches on and off with other poles ( Npole lead-make, lag-break)
Various accessories can be attached to the circuit breaker to extend its functions,
such as undervoltage release, shunt release, ON/OFF position indication contact,
and tripped position indication contact, for detail see the accessories part

Standard and certification


IEC 60947-2
KEMA, SEMKO, CB, CE

Delixi Electric

29

CDM1
Standard: IEC 60947-2

Type
CDM1-63

In A
3P

4P

CDM1-100

2P

3P

4P

CDM1-225

30

2P

10
16
20
25
32
40
50
63
10
16
20
25
32
40
50
63
16
20
25
32
40
50
63
80
100
16
20
25
32
40
50
63
80
100
16
20
25
32
40
50
63
80
100
100
125
160
180
200
225

Reference
Type M
CDM163M103
CDM163M163
CDM163M203
CDM163M253
CDM163M323
CDM163M403
CDM163M503
CDM163M633
CDM163M104
CDM163M164
CDM163M204
CDM163M254
CDM163M324
CDM163M404
CDM163M504
CDM163M634
CDM1100M162
CDM1100M202
CDM1100M252
CDM1100M322
CDM1100M402
CDM1100M502
CDM1100M632
CDM1100M802
CDM1100M1002
CDM1100M163
CDM1100M203
CDM1100M253
CDM1100M323
CDM1100M403
CDM1100M503
CDM1100M633
CDM1100M803
CDM1100M1003
CDM1100M164
CDM1100M204
CDM1100M254
CDM1100M324
CDM1100M404
CDM1100M504
CDM1100M634
CDM1100M804
CDM1100M1004
CDM1225M1002
CDM1225M1252
CDM1225M1602
CDM1225M1802
CDM1225M2002
CDM1225M2252

Type L
CDM163L103
CDM163L163
CDM163L203
CDM163L253
CDM163L323
CDM163L403
CDM163L503
CDM163L633
-----------------CDM1100L163
CDM1100L203
CDM1100L253
CDM1100L323
CDM1100L403
CDM1100L503
CDM1100L633
CDM1100L803
CDM1100L1003
----------------

Delixi Electric

CDM1
Standard: IEC 60947-2

Type
3P

4P

CDM1-400

3P

4P

CDM1-630

3P

4P

CDM1-800

3P

4P

CDM1-1250 3P

In A

Reference

100
125
160
180
200
225
100
125
160
180
200
225
200
225
250
315
350
400
200
215
250
315
350
400
400
500
630
400
500
630
400
500
630
700
800
400
500
630
700
800
700
800
1000
1250

Type M
CDM1225M1003
CDM1225M1253
CDM1225M1603
CDM1225M1803
CDM1225M2003
CDM1225M2253
CDM1225M1004
CDM1225M1254
CDM1225M1604
CDM1225M1804
CDM1225M2004
CDM1225M2254
CDM1400M2003
CDM1400M2253
CDM1400M2503
CDM1400M3153
CDM1400M3503
CDM1400M4003
CDM1400M2004
CDM1400M2254
CDM1400M2504
CDM1400M3154
CDM1400M3504
CDM1400M4004
CDM1630M4003
CDM1630M5003
CDM1630M6303
CDM1630M4004
CDM1630M5004
CDM1630M6304
CDM1800M4003
CDM1800M5003
CDM1800M6303
CDM1800M7003
CDM1800M8003
CDM1800M4004
CDM1800M5004
CDM1800M6304
CDM1800M7004
CDM1800M8004
CDM11250M7003
CDM11250M8003
CDM11250M10003
CDM11250M12503

Type L
CDM1225L1003
CDM1225L1253
CDM1225L1603
CDM1225L1803
CDM1225L2003
CDM1225L2253
------CDM1400L2003
CDM1400L2253
CDM1400L2503
CDM1400L3153
CDM1400L3503
CDM1400L4003
------CDM1630L4003
CDM1630L5003
CDM1630L6303
---CDM1800L4003
CDM1800L5003
CDM1800L6303
CDM1800L7003
CDM1800L8003
----------

Note: The connection mode for CDM1 is the fixed type front connection.

Delixi Electric

31

CDM1
Standard: IEC 60947-2

Key to overall dimensions


Type

Poles Overall dimensions


L

Install dimensions

L1

H1

H2

CDM1-63L

135 21

76

89.5

74

21

25

117

3.5

CDM1-63M

135 21

76

99

82

28

25

117

3.5

CDM1-63M

135 21

103 99

82

28

25

117

3.5

CDM1-100M

150 51

65

103.5

87

24

--

129

4.5

CDM1-100L

150 51

92

87

68

25

30

129

4.5

CDM1-100M

150 51

92

103.5

87

24

30

129

4.5

CDM1-100M

150 51

122 103.5

87

24

30

129

4.5

CDM1-225M

165 64

75

104

24.5

--

126

5.5

CDM1-225L

165 64

107 108

87

24.5

35

126

5.5

CDM1-225M

165 64

107 124.5

104

24

35

126

5.5

CDM1-225M

165 64

142 124.5

124.5

104

24.5

35

126

5.5

CDM1-400L,M 3

257 105 140 146

100

36.5

44

215

6.5

257 105 184 146

100

36.5

44

215

6.5

CDM1-630L,M 3

270 118

182 160

108

41

58

200

270 118

CDM1-400M
CDM1-630M

240 160

108

41

58

200

CDM1-800L,M 3

280 102 210 146

103

34.5

70

243

CDM1-800M

280 102 280 146

103

34.5

70

243

CDM1-1250M

406 104 210 190

140.5

58.5

70

375

10

Overall dimensions
Unit:mm

2P

32

3P

4P

Delixi Electric

CDM1
Standard: IEC 60947-2

Unit:mm

A
117
129
126
215
200
243

B
25
30
35
44
58
70

H
49
54
54
76
83
76

Unit:mm

A
35
35
65
60
48

Delixi Electric

B
11.5
31
15
15
15

H
46
48
61
61
66

33

CDM1
Standard: IEC 60947-2

Accessories
The accessories are fixed into the circuit breaker.

MN (Undervoltage Release)
Technical data
Rated operating voltage Us(V)
Drop-out voltage(V)
Pick-up voltage(V)

230V, 400V AC
(0.35~0.7) Us
(0.85~1.1) Us

MX (Shunt Release)
Technical data
Rated control voltage US(V)
Operating voltage(V)

230V, 400V AC
(0.7~1.1) US

OF (Auxiliary Contact)
Technical data
Rated thermal current Ith 3A
Rated operating voltage US(V)
1NO+1NC (Change over)
2NO+2NC (Change over)

0.4A (400V AC)

SD (Alarm Switch)
Technical data
Rated thermal current Ith 3A
Rated operating voltage US(V)

0.26A (400V AC)


0.4A (400V AC)

1NO+1NC

34

Delixi Electric

CDM1
Standard: IEC 60947-2

Ordering information
Voltage (V) Type
230V AC
400V AC

CDM1-63
CDM1-100
CDM1-225
CDM1-400
CDM1-630
CDM1-800
CDM1-1250

Delixi Electric

Reference
MN*
CDM163MN230
CDM163MN400
CDM1100MN230
CDM1100MN400
CDM1225MN230
CDM1225MN400
CDM1400MN230
CDM1400MN400
CDM1630MN230
CDM1630MN400
CDM1800MN230
CDM1800MN400
CDM11250MN230
CDM11250MN400

MX*
CDM163MX230
CDM163MX400
CDM1100MX230
CDM1100MX400
CDM1225MX230
CDM1225MX400
CDM1400MX230
CDM1400MX400
CDM1630MX230
CDM1630MX400
CDM1800MX230
CDM1800MX400
CDM11250MX230
CDM11250MX400

OF
CDM163OF

SD
CDM163SD

TR(Round Handle) TS(Square Handle)


CDM163TR
CDM163TS

CDM1100OF

CDM1100SD

CDM1100TR

CDM1100TS

CDM1225OF

CDM1225SD

CDM1225TR

CDM1225TS

CDM1400OF

CDM1400SD

CDM1400TR

CDM1400TS

CDM1630OF

CDM1630SD

CDM1630TR

CDM1630TS

CDM1800OF

CDM1800SD

CDM1800TR

CDM1800TS

CDM11250OF

35

CDM1L
Standard: IEC 60947-2

Function

CDM1L molded case circuit breakers with electronic type residual current operated
protection can be used to provide the following functions:
To distribute electric power and protect circuits and equipment against overload,
undervoltage, and short-circuit faults
To infrequently start and control AC motors
To protect users against indirect contact
To protect electrical installations against insulation faults (fire hazard, etc)

Description

Technical data
Main technical parameters are shown in the table below
Type

CDM1L-100

CDM1L-225

CDM1L-400

Frame size rated current A

100

225

400

Rated current In A

16 20 25 32 40

100 125 140 160 200 250 315

50 63 80 100

180 200 225

350 400

Rated frequency Hz

50

Rated insulation voltage Ui V

800

Rated operational voltage Ue V

400

Rated impulse withstand voltage Uimp V

8000

Number of poles

3P, 4P

Icu kA

Type M

50

50

70

(400V)

Type L

35

35

50

Ics kA

Type M

35

35

40

(400V)

Type L

22

22

30

Rated residual

Without delay 30/100/500

30/100/500

100/300/500

100/300/500

100/300/500

100/300/500

100/300/500

100/300/500

1/2 I n

1/2 I n

1/2 I n

Electrical

1500

1000

1000

Mechanical

8500

7000

4000

Total

10000

8000

5000

operating
current I

n mA

With delay

Rated residual non-operating


current I no mA
Durability

Maximum break time for residual operating current protection


Number of poles

I n

2I n

5I n

10 I n

Max. break

Without delay

0.2

0.1

0.04

0.04

time S

With delay

0.5/1.15/2.15 0.35/1/2

0.25/0.9/1.9 0.25/0.9/1.9

Table for 4 pole CDM1LE (Neutral line)


Code
Note

36

N(direct connect)

N(direct connect N pole lead-make, lag-break)

Delixi Electric

CDM1L
Standard: IEC 60947-2

Constructional features
Thermamagnetic release offers instantaneous trip against short-circuit and long time delay trip against overcurrent
The residual operating current value can be fixed or adjustable
The residual operating current protection can be with time-delay or without time-delay
Various accessories can be attached to the circuit breaker to extend its functions, such as undervoltage release, shunt release, ON/OFF position
indication contact, and tripped position indication contact, for detail see the accessories part

Standard and certification


IEC 60947-2
CE

Ordering information

Delixi Electric

37

CDM1L
Standard: IEC 60947-2

Type
CDM1L-100 3P

4P A

4P B

CDM1L-225 3P

4P A

4P B

CDM1-400

38

3P

Rated current Reference


In A
Type M
16
CDM1LE100M163
20
CDM1LE100M203
25
CDM1LE100M253
32
CDM1LE100M323
40
CDM1LE100M403
50
CDM1LE100M503
63
CDM1LE100M633
80
CDM1LE100M803
100
CDM1LE100M1003
16
CDM1LE100M164 A
20
CDM1LE100M204 A
25
CDM1LE100M254 A
32
CDM1LE100M324 A
40
CDM1LE100M404 A
50
CDM1LE100M504 A
CDM1LE100M634 A
63
80
CDM1LE100M804 A
CDM1LE100M1004 A
100
16
CDM1LE100M164 B
20
CDM1LE100M204 B
CDM1LE100M254 B
25
CDM1LE100M324 B
32
CDM1LE100M404 B
40
CDM1LE100M504 B
50
63
CDM1LE100M634 B
80
CDM1LE100M804 B
100
CDM1LE100M1004 B
100
CDM1LE225M1003
125
CDM1LE225M1253
140
CDM1LE225M1403
160
CDM1LE225M1603
180
CDM1LE225M1803
200
CDM1LE225M2003
225
CDM1LE225M2253
100
CDM1LE225M1004 A
125
CDM1LE225M1254 A
140
CDM1LE225M1404 A
160
CDM1LE225M1604 A
180
CDM1LE225M1804 A
200
CDM1LE225M2004 A
225
CDM1LE225M2254 A
100
CDM1LE225M1004 B
125
CDM1LE225M1254 B
140
CDM1LE225M1404 B
160
CDM1LE225M1604 B
180
CDM1LE225M1804 B
200
CDM1LE225M2004 B
225
CDM1LE225M2254 B
200
CDM1LE400M2003
250
CDM1LE400M2503
315
CDM1LE400M3153
350
CDM1LE400M3503
400
CDM1LE400M4003

Type L
CDM1LE100L163
CDM1LE100L203
CDM1LE100L253
CDM1LE100L323
CDM1LE100L403
CDM1LE100L503
CDM1LE100L633
CDM1LE100L803
CDM1LE100L1003
CDM1LE100L164
CDM1LE100L204
CDM1LE100L254
CDM1LE100L324
CDM1LE100L404
CDM1LE100L504
CDM1LE100L634
CDM1LE100L804
CDM1LE100L1004
CDM1LE100L164
CDM1LE100L204
CDM1LE100L254
CDM1LE100L324
CDM1LE100L404
CDM1LE100L504
CDM1LE100L634
CDM1LE100L804
CDM1LE100L1004
CDM1LE225L1003
CDM1LE225L1253
CDM1LE225L1403
CDM1LE225L1603
CDM1LE225L1803
CDM1LE225L2003
CDM1LE225L2253
CDM1LE225L1004
CDM1LE225L1254
CDM1LE225L1404
CDM1LE225L1604
CDM1LE225L1804
CDM1LE225L2004
CDM1LE225L2254
CDM1LE225L1004
CDM1LE225L1254
CDM1LE225L1404
CDM1LE225L1604
CDM1LE225L1804
CDM1LE225L2004
CDM1LE225L2254
CDM1LE400L2003
CDM1LE400L2503
CDM1LE400L3153
CDM1LE400L3503
CDM1LE400L4003

A
A
A
A
A
A
A
A
A
B
B
B
B
B
B
B
B
B

A
A
A
A
A
A
A
B
B
B
B
B
B
B

Delixi Electric

CDM1L
Standard: IEC 60947-2

Type

Rated current
In A
4P A 200
225
250
315
350
400
CDM1L-400 4P B 200
225
250
315
350
400

Reference
Type M
CDM1LE400M2004
CDM1LE400M2254
CDM1LE400M2504
CDM1LE400M3154
CDM1LE400M3504
CDM1LE400M4004
CDM1LE400M2004
CDM1LE400M2254
CDM1LE400M2504
CDM1LE400M3154
CDM1LE400M3504
CDM1LE400M4004

A
A
A
A
A
A
B
B
B
B
B
B

Overall dimensions

Type L
CDM1LE400L2004
CDM1LE400L2254
CDM1LE400L2504
CDM1LE400L3154
CDM1LE400L3504
CDM1LE400L4004
CDM1LE400L2004
CDM1LE400L2254
CDM1LE400L2504
CDM1LE400L3154
CDM1LE400L3504
CDM1LE400L4004

A
A
A
A
A
A
B
B
B
B
B
B

Unit:mm

Key to overall dimensions


Type
CDM1L-100L

Poles

3
4
CDM1L-100M 3
4
CDM1L-225L
3
4
CDM1L-225M 3
4
CDM1L-400L,M 3
4

Delixi Electric

Overall size
L1
L2
92max 150max
122max 150max
92max 150max
122max 150max
107max 165max
142max 165max
107max 165max
142max 165max
154max 257max
198max 257max

L3
94max
94max
110max
110max
94max
94max
110max
110max
146max
146max

L4
75max
75max
92max
92max
72max
72max
90max
90max
103max
103max

Installation size
a b
d
30 129 4
4.5
60 129 6
4.5
4.5
30 129 4
4.5
60 129 6
4.5
35 126 4
4.5
70 126 6
4.5
35 126 4
4.5
70 126 6
4.5
88 194 4
6.5
88 194 6

39

CDM1L
Standard: IEC 60947-2

Handle mechanism
Centrally revolvable type
Unit:mm

Square Handle

Dimension for handle mechanism


Frame

CDM1L-100

CDM1L-225

CDM1L-400

Dimension

49

55

74

Accessories
The accessories are fixed into the circuit breaker.

MN (Undervoltage Release)
Technical data
Rated operating voltage US(V)
Drop-out voltage(V)
Pick-up voltage(V)

40

230V, 400V AC
(0.35~0.7) Us
(0.85~1.1) Us

Delixi Electric

CDM1L
Standard: IEC 60947-2

MX (Shunt Release)
Technical data
Rated control voltage Us(V)
Operating voltage(V)

230V, 400V AC
(0.7~1.1) Us

OF (Auxiliary Contact)
Technical data
Rated thermal current Ith 3A
Rated operating voltage Us(V)
1NO+1NC (Change over)
2NO+2NC (Change over)

0.4A (400V AC)

SD (Alarm Switch)
Technical data
Rated thermal current Ith 3A
Rated operating voltage Us(V)

0.26A (400V AC)


0.4A (400V AC)

1NO+1NC

Ordering information
Voltage
(V)
230V AC
400V AC

Type
CDM1L-100
CDM1L-225
CDM1L-400

Delixi Electric

Reference
MN*
CDM1LE100MN230
CDM1LE100MN400
CDM1LE225MN230
CDM1LE225MN400
CDM1LE400MN230
CDM1LE400MN400

MX*
CDM1LE100MX230
CDM1LE100MX400
CDM1LE225MX230
CDM1LE225MX400
CDM1LE400MX230
CDM1LE400MX400

SD
TS(Square Handle) TR(Round Handle)
OF
CDM1LE100TR
CDM1LE100OF CDM1LE100SD CDM1LE100TS
CDM1LE225OF CDM1LE225SD CDM1LE225TS

CDM1LE225TR

CDM1LE400OF CDM1LE400SD CDM1LE400TS

CDM1LE400TR

41

CDW7
Standard: IEC 60947-2

Application
Applied to power distribution of AC 50Hz/60Hz, rated operational voltage 400/
690V, rated current 200A~6300A and lower
For power distribution and protecting circuit and power supply equipment aganist
harm from overload, undervoltage, short circuit, earthing, and other faults
Circuit breaker which ampere frame size is under 630A can protect motor aganist
overload,undervoltage and shortcircuit
Core parts use intelligent control unit which has accurate discrimination protection, it
can avoid unnecessary power failure and enhance the reliability of power supply
system

Standard and certification


International standard: IEC609472
Approved certification: CB, CE, KEMA

Operating condition and installation recommendation


Ambient temperature shall be controlled between
+40 and -5 , the average temperature in 24 hours
shall not exceed +35
Note:contacting manufacturer about circuit breaker
used in place where ambient temperature is higher
than +40 or lower than -5

42

Delixi Electric

CDW7
Standard: IEC 60947-2

Parameter and characteristics


Certification approved: IEC 60947-1 IEC 60947-2
CDW7-1000

CDW7-2000

CDW7-3200

CDW7-6300

3, 4

3, 4

3, 4

3, 4

400

400/690

400/690

400

690

800

800

800

8000

8000

8000

8000

50

50

50

50

200/400/630

630/800/1000

2000/2500

4000/5000

/800/1000

/1250/1600/2000

/3200

/6300

AC 400V

42

80

100

120

AC 690V

--

50

65

--

AC 400V

30

50

80

100

AC 690V

--

40

50

--

AC 400V

88

176

220

264

AC 690V

--

105

143

--

AC 400V

30

50

65

85

AC 690V

--

40

50

--

9000

9000

4500

1500

1000

1000

500

500

In
Icu
Ics
Icm

Delixi Electric

43

CDW7
Standard: IEC 60947-2

Protection characteristics

Fault and alarm reset button


Fault/Alarm LED
In normal state, this LED is off.
In case of fault release, the red LED will flash quickly; in case of
alarm, the red LED will be on constantly
Normal LED
As long as the controller is on and operates normally, the green
LED always flashes
Communication indicator
The communication state indication is as follows:
Profibus: OFF if no communication; ON if communication exists
Modbus: OFF if no communication; flash if communication exists
Device Net: Flash if no communication; ON if communication exists
Curve LEDs
Red LEDs exist behind the curve.
In case of fault release, the corresponding LED will flash
indicating the fault type;
During the parameter setting process, the LED is always on and
indicates the current item.
Keypad
Measure key l, used to switch to the default measurement menu.
Set key 2, used to switch to the parameter setting menu.
Protection Key 3, used to switch to the protection parameter setting menu.
Info key 4, used to switch to the historical record and maintenance menu.
Up, Move up the cursor through the menu items on the current level, or
increment the value of the selected parameter.
Down, Move down the cursor through the menu items on the current
level, or decrement the value of the selected parameter.
Exit, exit from the current level and return to the upper level, or cancel the
current parameter selection.
Select, Select to enter into the next level from the current item, or select the
current parameter, or store the change.

44

Delixi Electric

CDW7
Standard: IEC 60947-2

Delixi Electric

45

CDW7
Standard: IEC 60947-2

46

Delixi Electric

CDW7
Standard: IEC 60947-2

ECWS- H
Different curves

Four phase current (I1,

Up to 8 fault logs

LCD display of

MCR and out-of-limit

available for long time

I2, I 3, IN) and earth

Up to 8 alarm logs

Chinese GUI

tripping protection

delay protection

current

Up to 8 position logs

LED indication

DO Signal alarm function

Different curves

Thermal capacity

Historical current peak

Key operation

Communication function

available for inverse

Contact equivalence

short time delay protec-

Number of operating

tion

cycles

Definite short time delay

Clock function

protection

Self-diagnosis function

Instantaneous protection
Current unbalance (open
phase) protection
Earth protection
Earth fault alarm
Neutral phase protection
Load monitor
ECW - M

Long time delay protec-

Max. phase current

Fault log

Digital display

DO Signal alarm function

tion

Four phase current (I1,

Self-diagnosis

LED indication

MCR and out-of-limit

Definite time delay +

I2, I 3, IN) and earth

function

Key operation

tripping protection

inverse time delay for

current

Feature test

Digital setting of

Earth fault or leakage

function

protection param-

protection (either)

short time delay protec-

eters

tion
Instantaneous protection
Earthing protection
Load monitor
ECW - H

Different curves

Four phase current (I1,

Up to 8 fault logs

LCD display of

Over-voltage protection

available for long time

I2, I 3, IN) and earth

Up to 8 alarm logs

Chinese GUI

Under-voltage protection

delay protection

current

Up to 8 position logs

LED indication

Voltage unbalance

Different curves

Thermal capacity

Historical current

Key operation

protection

available for inverse

peak

Over-currency protection

short time delay protec-

Contact equivalence

Under-frequency

tion

Number of operating

protection

Definite short time delay

cycles

Phase protection

protection

Fault clock function

Inverse power protection

Instantaneous protection

Self-diagnosis fault

Demand protection

MCR and out-of-limit

log

Zonal system interlock

tripping protection

Self-diagnosis

protection

Current unbalance (open

function

Communication function

phase) protection

Feature test

Earth protection

function

Earth fault alarm


Neutral phase protection
Load monitor

Delixi Electric

47

CDW7
Standard: IEC 60947-2

CDW7-1000

CDW7-2000~6300

ECWS-H intelligent control-

ECW-M intelligent controllers ECW-H intelligent controllers

lers
Ir1=(0.4~1)ln
1.05
1.3
1.5Ir1

Ir1 h
Ir1 h

Ir1=(0.4~1)ln

Ir1=(0.4~1)ln

2h

2h

2h

2h

1h

8,12.8,19.2,32,48,64,80,

1h

15,30,60,120,240,480

108,144,224,320,480,640,

15,30,60,120,240,360,480,
600,720,840,960

800,960,1120
2.0Ir1

3.32,5.32,8.00,13.32,20.00, 8.4,16.9,33.8,67.5,135,270

8.4,16.9,33.8,67.5,135,202.

26.66,33.30,45.00,60.00,

5,270,337.5,405,472.5,540

93.32,133,200,266,333,
400,433
3.0Ir1

1.25,2.00,3.00,5.00,7.50,
10.0,12.5,16.8,22.5,35.0,
50.0,75.0,100,125,150,162

Ir2=(1.5~15)In
Ts=K/10(N2-1),(Ts

Ir2=(1.5~15)In

Ir2=(0.4~15)In

15%

10%

10%
20ms)

I2Ts= 8Ir1)2ts

Ts=K/10(N2 -1),(Ts

0.1,0.2,0.3,0.4

0.1,0.2,0.3,0.4

0.1,0.2,0.3,0.4

0.06,0.13,0.2,0.27

0.06,0.16,0.25,0.34

0.06,0.13,0.2,0.27

ECWS-H ECW-H

ECW-M

CDW7-1000~6300A

CDW7-2000

(1.0~20)ln

Ir3=1In~50KA+OFF Ir3=1In~75KA+OFF IIr3=1In~100KA+OFF

15%
Ir4=(0.2~1.0)In
10%

15%
Ir4=(0.2~1.0)In
10%

CDW7-3200

20ms)

CDW7-6300

15%

15%
Ir4=(0.2~1.0)In
10%

0.1s~1s (Rank difference 0.1s) 0.1~0.4s (Rank difference 0.1s) 0.1s~1s(Rank difference 0.1s)

48

Delixi Electric

CDW7
Standard: IEC 60947-2

Auxiliary functions

AC 380V

AC220V

(0.35~0.7)Ue

(0.35~0.7)Ue

(0.85~1.1)Ue

(0.85~1.1)Ue
0.35Ue

0.35Ue
36VA

24VA

5VA

5VA

AC380

AC220

DC220

36VA

24VA

24W

DC110
24W

5VA

5VA

5W

5W

(0.7~1.1)Us
less than 30ms

7-2000~6300

AC380

AC220

DC220

DC110

36VA

24VA

24W

24W

10VA

10VA

10W

10W

(0.85~1.1)Us
less than 70ms

Delixi Electric

49

CDW7
Standard: IEC 60947-2

AC380

AC220

DC220

CDW7-

In

2000A

85VA

85VA

85VA

85VA

2000~6300 2000A
3200A

In

3200A

110VA

110VA

110VA

110VA

In

6300A

150VA

150VA

150VA

150VA

80VA

80VA

80VA

80VA

CDW7-1000

DC110

(0.85~1.1)Us
less than 5s

U/Ue
cos

Pe

50

DC-13

10

0.3

6Pe

I/Ie

10

1.1

U/Ue

1.1

1.1

0.3

6Pe

10

10

cos

0.95

AC-15

T0.

50W T0.95es upper limit

300ms

Delixi Electric

CDW7
Standard: IEC 60947-2

Overall and mounting dimension

CDW7-1000A fixed circuit breaker outline and horizonal/vertical connected dimension


L
L1
200, 400
266
244
630
266
244
800, 1000
266
244
200, 400
336
314
630
336
314
800, 1000
336
314
Delixi Electric

L2
70
70
70

N
6
12
12
8
16
16
51

CDW7
Standard: IEC 60947-2

CDW7-1000A drawout type circuit breaker outline and horizonal/vertical wiring


200, 400
630
800, 1000
200, 400
630
800, 1000
52

3P

4P

L
284
284
284
354
354
354

L1
194
194
194
264
264
264

Unit:mm
L2
70
70
70

L3
55
75
75
55
75
75

L4
63
83
83
63
83
83

n
6
12
12
8
16
16

H
6
8
10
6
8
10
Delixi Electric

CDW7
Standard: IEC 60947-2

CDW7-2000A~3200A

CDW7-2000A fixed circuit breaker vertical connection diagram

CDW7-2000A~3200A fixed circuit breaker overall and horizonal/vertical wiring


CDW7-2000

CDW7-3200

Unit:mm

L1

L2

L3

L4

In A

3P

362

318

292

340

400~800

4P

457

413

292

435

1000~1600

457

413

292

435

2000

3P

422

378

352

400

2000~2500

4P

537

493

352

515

3200

a
10
15
20
20
30

CDW7-2000 mounting dimension is same regardless of different current used in"horizonal-wiring" or"vertical-wiring"

Delixi Electric

53

CDW7
Standard: IEC 60947-2

CDW7-2000A~6300A

CDW7-2000A drawout circuit breaker vertical connection diagram

CDW7-2000A~6300A drawout type circuit breaker outline and horizonal/vertical connection


CDW7-2000

CDW7-3200

CDW7-6300
(4000/5000A)
CDW7-6300

3P
4P
3P
4P
4000A
3P
4P
3P

L1
375
375
470
435
550
550
813
928
928

L2
335
335
430
395
510
510
773
888
888

L3
292
292
292
352
352
352
352
352
352

L4
265
265
360
325
440
440
703
818
818

L5
247
247
247
307
307
307
307
307
307

W1
461
461
461
471
471
494
494
494
494

Unit:mm
W2
507
507
507
517
517
540
540
540
540

b
179
179
179
189
189
212
212
212
212

In A
400~800
1000~1600
2000
2000~2500
3200~4000
3200~4000
4000
5000~6300
5000~6300

a
10
15
20
20
30
30
20
30
30

W7-3200 can expand to 4000A,which mounting dimension is as same as 4P of CDW7-3200


DW7-2000 the mounting dimension is same regardless of different current used in"horizonal-connected" or "vertical-connected"
54

Delixi Electric

CDW7
Standard: IEC 60947-2

CDW7-1000

CDW7-1000A

CDW7-1000A

CDW7-2000~6300

CDW7-2000~6300A

CDW7-2000~6300A

CDW7-2000~6300 panel cut-out dimension and mounting dimension


a

Unit:mm
c
3P

4P

CDW7-2000

306

346

47.5

CDW7-3200

366

406

57.5

CDW7-6300

366

406

189(4000/5000A)

246.5(4000/5000A)

246.5(6300A)

--

Delixi Electric

55

CDW7
Standard: IEC 60947-2

Auxiliary connection diagramn

F X with different current ratings shall connect with different sources.

41 42 when controller power choose DC,the output is DC24V,user can select DC


power module
43 44 circuit breaker status detection terminal(used when MCR function included)
45 overload pre-alarm signal output
46 automatic diagnosis alarm signal output
47 fault trip alarm signal output
48 earthing but non-tripping,only alarm signal output
49 four groups of contacts output common terminal
50 51 externally sensor input terminal
58 able to directly connect to power supply(automatic pre-energization),also able
to join up with normal open pushbutton to connect to power supply(manual preenergization)

56

Delixi Electric

CDW7
Standard: IEC 60947-2

Pin functions:
Pin 1# and 2#: Auxiliary power input,pin 1# is
positive for DC input
Pin 3#, 4#, 5#: Fault trip contact output (4# is
common terminal); contact capacity: AC380V, 16A
Pin 6# and 7#, 8# and 9#: Two groups of auxiliary
contacts for breaker status; contact capacity:
AC380V, 16A
12#,13#(Contact1)and 14#,15#(Contact2)and 16#,
17#(Contact3)and 18#,19#(Contact4):Output of
four groups of signal for controllers,contact
capacity:4A/240V 7A/24VDC
20#: Earth protection
21#~24#:input of voltage signal (Note:the order cant
be wrong)
Components:
Q - Under-voltage release
F - Shunt release
X Closing electromagnet
DF - Auxiliary switch
M - Motor
SB1Button for closing
SB2Button for shunt

Delixi Electric

Note: 1. If the control voltage values of Q, F, X, and M are different to each


other, these components can be connected to different power supply units; in the
application, the shunt release and closing electromagnet shall be connected
serially with normally open and normally closed auxiliary contacts (the part
enclosed by dotted lines shall be connected by the user; the part represented by a
two-dot chain line is the wiring of circuit 51);
Note 2: The pin 35# can be connected to the power supply directly (automatic
pre-energy storage) or connected serially to a normally open button and then to
the power supply (manual pre-energy storage);
Note 3: If the user requests, pin #6~#7 can be connected to normally closed
contacts;
Note 4: The ECW power supply module I is a DC power supply module, and it
can be omitted if the power supply is AC power supply; the polarity and lead-ins/
lead-outs shall not be reversed (for draw-out type circuit breakers, the lead-outs
of the power supply module has been connected before the circuit break is
shipped from the factory);
Note 5: In case of circuit 47, the auxiliary contacts are four closed and four
open contacts; pin #25 and #26 are input terminals of an external current transformer , used for earth fault protection as (3P+N)T type ;
Note 6: In case of circuit 51, the auxiliary contacts are six closed and six open
contacts (or five closed and five open contacts); pin #25, #26, and #51 form
normally open and normally closed contacts;
Note 7: If Profibus or any other protocol is used, ECW-H + DP conversion module
and other conversion modules must be ordered; ECW power supply module lV and
ECW201 relay module must be ordered separately;
Note 8:Pin #12~#19 input/output contacts can be user-defined programmable
signal contacts.

57

CDW7
Standard: IEC 60947-2

2: terminal 35# can directly connect to power supply


(automatic pre-energy storage),or join up with normal open
pushbutton to connect power supply(manual pre-energy
storage)
3: terminal 6#~7# can lead out normal close contact if user
suggested
4: ECW power supply module is DC power supply module,
the module doesn't exist when power supply current is AC,
polarity,incoming line and leading-out line shall not connected reversely(leading-out terminal of power supply module in drawout type had been connected before sale)
5: in 47 circuit,auxiliary contact is 4 open 4 close;25# 26# is
input terminal of external sensor
6: in 51 circuit,auxiliary contact is 6open6close(5open
5close);25#

26# 51# form normal open normal close

contact(earth-leakage protection excluded)


7: if using profibus or other protocols, user shall order
ECW-H+HP transformation module and others;ECW power
supply moduleV,ECW201 relay module and others shall
order seperately

1# 2#: 1# is the front terminal when DC is supplied by auxiliary power


3# 4# 5
AC380V 16A
6# 7#
8# 9#:
two groups of circuit breaker status auxiliary terminal:
AC380V 16A
10# 11#: respectively as the communication leading-out of RS485A ,RS485B
12#: overload pre-alarm signal output
13#: communication remote control shunt release output
14#: communication remote control closing output or instantaneous short time-delay
trip signal output
15#: communication remote control energy storage or long time-delay trip signal output
16#: S-earth(RS-485 transmissionn common ground wire
17#: load monitor output1
18#: load monitor signal 2
19#: signal output common earth wire
20#: PE line ,shield earth wire
21#: neutral voltage signal N phase
22#: voltage signal A phase
23#: voltage signal B phase
24#: voltage signal C phase

8: #12~#19 output input contacts are programmableselfdefined signal contaccts

58

Delixi Electric

CDW7
Standard: IEC 60947-2

Other additional parameter

Delixi Electric

59

CDW7 Series Air Circuit Breakers

Order Instructions

Customer

Sets purchased

Date

Mode CDW7

Fixed

Draw-out

Rated voltage

AC400

AC690

H Type Intelligent electronic trip

Basic function

3 Poles

4Poles

Rated current

In= A

Overload long delay

Short-circuit short

Short-circuit instantaneous

time protection

delay time protection

protection

Load monitoring function

Metering function

Earthing protection

(Not available for L type)

Power supply

AC 230V

AC 400V

DC 220V

DC 110V

Under-voltage instantaneous trip

AC 230V

Under-voltage time-delay trip

1s

AC 400V

Under-voltage trip
3s

5s

Accessaries

Shunt trip

AC 230V

AC 400V

DC 220V

DC 110V

Energy releasing electromagnet

AC 230V

AC 400V

DC 220V

DC 110V

Motor Driven

AC 230V

AC 400V

DC 220V

DC 110V

Interphase barrier

Escutcheon

N phase external connection

Earth-leakage CT(Only for cable)

Auxiliary switch

standard(4a4b)

special(6a6b)

Auxiliary Connection Terminal


Mechanical interlock

1-lock,1-key

2-lock,1-key

3-lock,1-key

Steel-cable interlock

Interlocking rod with 2 switches

Interlocking rod with 3 switches

Door interlock(Available for Draw-out type)

Note:for any special requirement,please contact with the manufacturer.

60

Delixi Electric

CDC17
Standard: IEC 60947-4-1

Function

Description

Technical data
Main circuit
Rated insulation voltage: 690 V
Rated operational voltage: up to 660 V
Frequency limits: 50/60 Hz
Rated operational current and power of controlled motors are shown in the table
below
Control circuit
Control circuit supply voltage Us:
AC 36V, 110V, 127V, 220/230V, 380/400V
DC 110V, 220V
Technical features
Compact, light, low consumption, long-life durability
Flame-resistant enclosure ensures a safe & reliable service
Full range auxiliaries:
- auxiliary contact module
- time delay module
- mechanical interlock module
Direct connection with thermal overload relay to form electomagnetic starter

Standard and certification


IEC 60947-4-1
KEMA, CE

Delixi Electric

61

CDC17
Standard: IEC 60947-4-1

Overall dimensions

CDC17-9~32

CDC17-40~95

CDC17-115~150

CDC17-185~330

CDC17-400~500

CDC17-630~1000

Installation dimensions

unit:mm

Type

Amax

Bmax

Cmax

C1max

C2max

CDC17-9~12

45

68

77

109

133

35

0.21

59

0.28

4.5

CDC17-18

45

68

82

115

138

CDC17-25

56.5

79

91

124

149

40

0.21

66

0.43

4.5

CDC17-32

56.5

79

95

127

152

CDC17-40~65

75

127

115

145

170

40

0.21

105

CDC17-80~95

85

127

123

153

178

Note:C1max-Contactor+CDF4

0.57

6.5

C2max-Contactor+CDLA

Type

A1

C1

a1

a2

a3

b1

b2

CDC17-185

138

111

180

163

95

40

20

80

158

154

150

CDC17-225

138

111

199

163

95

48

25

80

172

172

11

150

CDC17-265, 330

171

144

207

201

119

48

25

96

180

180

11

166

11

62

b3

Delixi Electric

CDC17
Standard: IEC 60947-4-1

Characteristics
Model
Rated operational
current A

380V / 400V
660V

AC-3
AC-4
AC-3
AC-4

Rated operational voltage V


Rated insulation voltage V
Rated conventional thermal current A
Power of controlled 3-phase cage motor(AC-3) 380V/400V
kW
660V
AC-3
Electric durabilities(x104 operations)
Operating rate(cycles/h)
Electric durabilities(x104 operations)
Operating rate(cycles/h)
Mechanical durabilities(x104 cycles)
AC Coil
Coil voltage V
AC-4

Accessories

Operational voltage V
Drop-out voltage V
Inrush VA
Sealed VA
Heat dissipation W
Auxiliary contact
Time-delay block
Mechanical Interlock

Matched Relay
Matched Fuse
Cross Section
of Cable mm2
Weight Kg

Delixi Electric

Number of Piece
Flexible cable
Inflexible cable

Front mount
Side mount
Front mount

CDC17-9
CDC17-12
9
12
3.5
5
6.6
8.9
1.5
2
380 / 400
660
690
20
4
5.5
5.5
7.5
100
1200
20
300
1000
36, 48, 110, 220, 380
85%~110%Us
20%~75%Us
70
8
1.8~2.7
CDF4
CDLA2 or CDLA3
CDJL17-1
CDR17-18
RT16-20
1
2
1
2
2.5
4
0.315

CDC17-18
18
7.7
12
3.8

CDC17-25
25
8.5
18
4.4

CDC17-32
32
12
21
7.5

32
7.5
9

40
11
15

50
15
18.5
80

800

110
11
3~4

RT16-32
1
2
4
6
0.335

CDR17-32
RT16-40
1
2

0.513

RT16-50
1
2
6
10
0.510

63

CDC17
Standard: IEC 60947-4-1

Model
Rated operational
current A

380V / 400V
660V

AC-3
AC-4
AC-3
AC-4

Rated operational voltage V


Rated insulation voltage V
Rated conventional thermal current A
Power of controlled 3-phase cage motor(AC-3) 380V/400V
kW
660V
AC-3
Electric durabilities(x104 operations)
Operating rate(cycles/h)
Electric durabilities(x104 operations)
Operating rate(cycles/h)
Mechanical durabilities(x104 cycles)
AC Coil
Coil voltage V
AC-4

Accessories

Operational voltage V
Drop-out voltage V
Inrush VA
Sealed VA
Heat dissipation W
Auxiliary contact
Time-delay block
Mechanical Interlock

Matched Relay
Matched Fuse
Cross Section
of Cable mm2
Weight Kg

64

Number of Piece
Flexible cable
Inflexible cable

Front mount
Side mount
Front mount

CDC17-40
CDC17-50
40
50
18.5
24
34
39
9
12
380 / 400
660
690
60
80
18.5
22
30
33
80
1200
20
300
800
36, 48, 110, 220, 380
85%~110%Us
20%~75%Us
200
20
6~10
CDF4
CDLA2 or CDLA3
CDJL17-2
CDR17-95
RT16-63
RT16-80
1
2
1
2
10
16
16
25
1.14

CDC17-65
65
28
42
14

CDC17-80
80
37
49
17.3

30
37

125
37
45
60

CDC17-95
95
44
55
21.3

45

600

RT16-100
1
2
25
25
-

RT16-125
1
2
50
25
50
1.35

RT16-200
1
2
50
25
50
-

Delixi Electric

CDC17
Standard: IEC 60947-4-1

Model
Rated operational
current A

380V / 400V
660V

AC-3
AC-4
AC-3
AC-4

Rated operational voltage V


Rated insulation voltage V
Rated conventional thermal current A
Power of controlled 3-phase cage motor(AC-3) 380V/400V
kW
660V
AC-3
Electric durabilities(x104 operations)
Operating rate(cycles/h)
Electric durabilities(x104 operations)
Operating rate(cycles/h)
Mechanical durabilities(x104 cycles)
AC Coil
Coil voltage V
AC-4

Accessories

Operational voltage V
Drop-out voltage V
Inrush VA
Sealed VA
Heat dissipation W
Auxiliary contact
Time-delay block
Mechanical Interlock

Matched Relay
Matched Fuse
Cross Section
of Cable mm2
Weight Kg

Delixi Electric

Number of Piece
Flexible cable
Inflexible cable

Front mount
Side mount
Front mount

CDC17-115 CDC17-150
115
150
52
60
86
110
49
61
380 / 400
660
690
150
55
75
80
100
60
1200
20
300
600
36, 48, 110, 220, 380
85%~110%Us
20%~75%Us
559
33
9.5
CDFC17-11,CDFC17-12
CDJL17-3
CDR17-185
RT16-200
1
2
1
2
95
50
120 20x3 25x3
2.15

CDC17-185
185
79
118
69

CDC17-225
225
85
135
82

CDC17-265
265
105
170
98

CDC17-330
330
117
225
118

210
90
110

225
110
129

300
132
160

300
160
220

300
30
600

1198
83
18.9

695
45
13.5

RT16-250
1
2
150 25x3

JR20-250
RT16-250
1
2
185 32x4

JR20-400
RT16-400
1
2
240 32x4
6.6

1
240
6.6

2
30x5

65

CDC17
Standard: IEC 60947-4-1

Model
Rated operational
current A

380V / 400V
660V

AC-3
AC-4
AC-3
AC-4

Rated operational voltage V


Rated insulation voltage V
Rated conventional thermal current A
Power of controlled 3-phase cage motor(AC-3) 380V/400V
kW
660V
AC-3
Electric durabilities(x104 operations)
Operating rate(cycles/h)
Electric durabilities(x104 operations)
Operating rate(cycles/h)
Mechanical durabilities(x104 cycles)
AC Coil
Coil voltage V
AC-4

Accessories

Operational voltage V
Drop-out voltage V
Inrush VA
Sealed VA
Heat dissipation W
Auxiliary contact
Time-delay block
Mechanical Interlock

Matched Relay
Matched Fuse
Cross Section
of Cable mm2
Weight Kg

66

Number of Piece
Flexible cable
Inflexible cable

Front mount
Side mount
Front mount

CDC17-400
CDC17-500
400
500
138
147
305
355
135
145
380 / 400
660
690
500
220
265
280
335
60
300
20
30
600
110, 220, 380
85%~110%Us
20%~75%Us
780
10
8
CDFC17-21
JR20-400
JR20-630
RT16-500
RT16-630
2
150
185
30x5
40x5
9.36

CDC17-630
630
188
460
170

CDC17-800
800
242
530
215

CDC17-1000
1000
580
-

800
335
450

450
500

1000
560
560

600

1050
12
10

RT16-800
240
50x5
22.8

RT17-4/1000

RT17-4/-1250

60x5

80x5

Delixi Electric

CDC17
Standard: IEC 60947-4-1

Ordering information
Rate current (A)

Contact blooks
NO
NC
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

9
12
18
25
32
40
50
65
80
95
115
150
185
225
265
330
400
500
630
800
1000

coil voltage code


coil voltage (V)

frequency code
frequency

Delixi Electric

36
C

50Hz
5

48
E

Reference
CDC17910
CDC17901
CDC171210
CDC171201
CDC171810
CDC171801
CDC172510
CDC172501
CDC173210
CDC173201
CDC174011
CDC175011
CDC176511
CDC178011
CDC179511
CDC1711522
CDC1715022
CDC1718522
CDC1722522
CDC1726522
CDC1733022
CDC1740022
CDC1750022
CDC1763022
CDC1780022
CDC17100022

110
F

220
M

380
Q

60Hz
6

67

CDC17
Standard: IEC 60947-4-1

Description

Application scope

CDF4-20 Top auxiliary contact

CDF420

CDF4-11 Top auxiliary contact

CDF411

CDF4-02 Top auxiliary contact

CDF402

CDF4-22 Top auxiliary contact

CDF422

CDF4-13 Top auxiliary contact

CDC17-9~95A

CDF413

CDF4-31 Top auxiliary contact

CDF431

CDF4-04 Top auxiliary contact

CDF404

CDF4-40 Top auxiliary contact

CDF440

CDLA2 On delay 0.1~3S

CDFC1711

CDLA2 On delay 0.1~30S


CDLA2 On delay 10~180S

CDFC1712
CDC17-9~95A

CDFC1721

CDLA3 off delay 0.1~3S

CDLA2ON0

CDLA3 off delay 0.1~30S

CDLA2ON2

CDLA3 off delay 10~180S

68

Reference

CDLA2ON4

CDFC17-11 Side auxiliary contact

CDC17-115~330A

CDLA3OFF0

CDFC17-12 Side auxiliary contact

CDC17-115~330A

CDLA3OFF2

CDFC17-21 Side auxiliary contact

CDC17-400~1000A

CDLA3OFF4

CDJL17-1 Mechanical interlocking module CDC17-9~32A

CDJL171

CDJL17-2 Mechanical interlocking module CDC17-40~95A

CDJL172

CDJL17-3 Mechanical interlocking module CDC17-115~330A

CDJL173

Delixi Electric

CDR17
Standard: IEC 60947-4-1 60947-5-1

Function

CDR17 series thermal overload relays provide:


Protection of circuits and motors against overload
Protection of circuits and motors against phase loss
Motor starters installation in association with contactors

Description

Technical data
Main circuit:
Frequency limits: 50/60 Hz
Rated insulation voltage: 690 V
Rated operational voltage: up to 690 V
Frame size rated current: 18, 32, 95, 185A
Rated operational current and range of current setting are shown in the table
below
Table 1
Type

Rated
insulation
voltage
Ui V

CDR17-18 690

CDR17-32 690

Delixi Electric

Frame Rated Thermal protection


size
current No
Rated
Range of
rated
Ie A
current
current
current
setting A setting A

Reference

18

32

18

32

1801

0.15

0.1~0.13~0.15

CDR1718P15

1802

0.18

0.12~0.16~0.18

CDR1718P18

1803

0.25

0.18~0.2~0.25

CDR1718P25

1804

0.36

0.25~0.32~0.36

CDR1718P36

1805

0.5

0.35~0.4~0.5

CDR1718P5

1806

0.7

0.5~0.6~0.7

CDR1718P7

1807

0.9

0.63~0.72~0.9

CDR1718P9

1808

1.2

0.9~1~1.2

CDR17181P2

1809

1.8

1.2~1.6~1.8

CDR17181P8

1810

2.5

1.8~2~2.5

CDR17182P5

1811

3.6

2.5~3.2~3.6

CDR17183P6

1812

4.8

3.5~4~4.8

CDR17184P8

1813

6.3

4.5~5~6.3

CDR17186P3

1814

5~6~7

CDR17187

1815

6.3~7.2~9

CDR17189

1816

12

9~10~12

CDR171812

1817

15

11~13~15

CDR171815

1818

18

14~16~18

CDR171818

3201

6.3

4.5~5~6.3

CDR17326P3

3202

5~6~7

CDR17327

3203

6.3~7.2~9

CDR17329

3204

12

9~10~12

CDR173212

3205

18

12~16~18

CDR173218

3206

25

18~20~25

CDR173225

3207

32

23~25~32

CDR173232

69

CDR17
Standard: IEC 60947-4-1 60947-5-1

Type

Frame Rated Thermal protection


current No
size
Rated
Range of
Ie A
rated
current
current
current
setting A setting A

Reference

CDR17-95 690

95

CDR17-185 690

185

95

185

9501

12

9~10~12

CDR179512

9502

18

12~16~18

CDR179518

9503

25

18~20~25

CDR179525

9504

32

23~25~32

CDR179532

9505

40

30~36~40

CDR179540

9506

50

37~45~50

CDR179550

9507

65

48~55~65

CDR179565

9508

70

55~63~70

CDR179570

9508

80

63~70~80

CDR179580

9510

95

75~90~95

CDR179595

8501

50

37~45~50

CDR1718550

8502

65

48~55~65

CDR1718565

8503

70

55~63~70

CDR1718570

8504

80

63~70~80

CDR1718580

8505

95

75~90~95

CDR1718595

8506

115

90~100~115

CDR17185115

8507

135

105~115~135

CDR17185135

8508

150

120~135~150

CDR17185150

8509

160

130~150~160

CDR17185160

8510

185

150~160~185

CDR17185185

Table 2 Basic data for control circuit and auxiliary circuit


Rated
Conventional Circuit
insulation free air thermal type
voltage V current A
690

Utilization Rated
Rated
Rated
category frequency operational current
Hz
voltage V A

Control AC-15

50

circuit
DC-13
Auxiliary AC-15

50

circuit

Rated
control
capacity

220(230)

1.64(1.57) 360 VA

380(400)

0.95(0.90)

660(690)

0.55(0.52)

220(230)

0.23(0.22) 50 W

220(230)

380(400)
660(690)
DC-13

220(230)

Table 3 Limits of operation of relays when energized on all poles


Sequence Multiples of
Tripping time
current setting

Initial condition

Ambient air
temperature

1.05

Non-trip within 2 hours

From cold

+20 oC

1.2

<2h

From hot(immediately

1.5

Trip

<2min

following sequence 1

<4min

test)

10A

2s<TP10s

From cold

10

4s<TP10s

10A

class 10
4

70

7.2

Delixi Electric

CDR17
Standard: IEC 60947-4-1 60947-5-1

Table 4 Limits of operation when energized on two poles


Sequence Multiples of current setting
Tripping time Initial condition
Any two poles The third-pole

Ambient air
temperature

1.0

0.9

+20 oC

1.15

Non-trip

From cold state

within 2 hours
<2h

From hot state


(immediately following
sequence 1 test)

Table 5 Temperature compensation characteristic


Sequence

Multiples of
Tripping time Initial condition
current setting

Ambient air
temperature

1.0

>2h

From cold state

+55 oC

1.2

<2h

From hot state(immediately

1.05

>2h

From cold state

1.30

<2h

From hot state(immediately

0.95

>2h

From cold state

1.2

<2h

From hot state(immediately

1.05

>2h

From cold state

1.35

<2h

From hot state(immediately

following sequence 1 test)


-10 oC

following sequence 3 test)


+60 oC

following sequence 5 test)


-20 oC

following sequence 7 test)

Overall dimensions

CDR17-18

Delixi Electric

71

CDR17
Standard: IEC 60947-4-1 60947-5-1

CDR17-32

CDR17-95

CDR17-185

72

Delixi Electric

LMK Current Transformer


Standard: BS7626, IEC44-1

Function

LMK Current Transformer provide:


Measuring current

Description

Technical Data
Primary current: 100A-5000A
Secondary approval: 5A, 1A
Maximum voltage: 0.66kV
Class: 0.5, 1.0, 3.0
Short time thermal current: Ith=100Ih
Rated security coefficient: FS<5

Standard and Certification


BS7626, IEC44-1

Overall dimensions

Unit: mm

Delixi Electric

Model

LMK-0.66-20

87

68

42

LMK-0.66-30

79

60

37

LMK-0.66-40

99

75

40

LMK-0.66-50

99

82

40

LMK-0.66-60

126

102

40

LMK-0.66-80

118

125

40

LMK-0.66-100

136

170

40

LMK-0.66-120

136

190

41

73

LMK Current Transformer


Standard: BS7626, IEC44-1

Class:
0.5
Maximum Voltage: 0.66KV
Model

Current ratio Rated Load Bar


(VA)
(A)
(mm)

30/5
50/5
75/5
100/5
100/5
150/5
200/5
LMK-0.66-30 100/5
200/5
250/5
300/5
LMK-0.66-40 250/5
300/5
400/5
500/5
LMK-0.66-50 300/5
400/5
500/5
600/5
750/5
800/5
1000/5
LMK-0.66-60 500/5
600/5
750/5
800/5
1000/5
1200/5
1500/5
LMK-0.66-80 600/5
750/5
800/5
1000/5
1200/5
1500/5
2000/5
2500/5
LMK-0.66-100 600/5
750/5
800/5
1000/5
1200/5
1500/5
2000/5
2500/5
3000/5
LMK-0.66-120 1500/5
2000/5
2500/5
3000/5
4000/5
5000/5
LMK-0.66-20

74

5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
10-3.75
10-3.75
10-3.75
10-3.75
5-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
15-3.75
15-3.75
20-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
15-3.75
15-3.75
20-3.75
20-3.75
15-3.75
15-3.75
20-3.75
20-3.75
25-3.75
25-3.75

30
30
30
40
40
40
40
50
50
50
50
50
50
50
60
60
60
60
60
60
60
80
80
80
80
80
80
80
80
100
100
100
100
100
100
100
100
100
120
120
120
120
120
120

10
10
10
10
10
10
10
10
10
10
10
10
10
10
20
20
20
20
20
20
20
10 or 60
10 or 60
10 or 60
10 or 60
10 or 60
10 or 60
10 or 60
10 or 60
10 or 80
10 or 80
10 or 80
10 or 80
10 or 80
10 or 80
10 or 80
10 or 80
10 or 80
10 or 80
10 or 80
10 or 80
10 or 80
10 or 80
10 or 80

Diameter Number of Turns


Reference
through the core
(mm)

30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30

20
20
20
20
20
20
20
20
20
20
20
30
30
30
30
35
35
35
35
35
35
35
45
45
45
45
45
45
45
50
50
50
50
50
50
50
50
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60

5
3
2
2
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

LMKP63020
LMKP65020
LMKP67520
LMKP610020
LMKP610020
LMKP615020
LMKP620020
LMKP610030
LMKP620030
LMKP625030
LMKP630030
LMKP625040
LMKP630040
LMKP640040
LMKP650040
LMKP630050
LMKP640050
LMKP650050
LMKP660050
LMKP675050
LMKP680050
LMKP6100050
LMKP650060
LMKP660060
LMKP675060
LMKP680060
LMKP6100060
LMKP6120060
LMKP6150060
LMKP660080
LMKP675080
LMKP680080
LMKP6100080
LMKP6120080
LMKP6150080
LMKP6200080
LMKP6250080
LMKP6600100
LMKP6750100
LMKP6800100
LMKP61000100
LMKP61200100
LMKP61500100
LMKP62000100
LMKP62500100
LMKP63000100
LMKP61500120
LMKP62000120
LMKP62500120
LMKP63000120
LMKP64000120
LMKP65000120

Delixi Electric

LMK Current Transformer


Standard: BS7626, IEC44-1

Class:
1
Maximum Voltage: 0.66KV
Model
LMK-0.66-20

Current ratio Rated Load Bar


(VA)
(A)
(mm)

30/5
50/5
75/5
100/5
150/5
200/5
LMK-0.66-30 100/5
200/5
250/5
300/5
LMK-0.66-40 250/5
300/5
400/5
500/5
600/5
LMK-0.66-50 300/5
400/5
500/5
600/5
750/5
800/5
1000/5
1200/5
LMK-0.66-60 500/5
600/5
750/5
800/5
1000/5
1200/5
1500/5
2000/5
LMK-0.66-80 600/5
750/5
800/5
1000/5
1200/5
1500/5
2000/5
2500/5
LMK-0.66-100 600/5
750/5
800/5
1000/5
1200/5
1500/5
2000/5
2500/5
3000/5
LMK-0.66-120 1500/5
2000/5
2500/5
3000/5
4000/5
5000/5

Delixi Electric

5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
10-3.75
5-3.75
5-3.75
5-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
5-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
15-3.75
15-3.75
20-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
15-3.75
15-3.75
20-3.75
20-3.75
15-3.75
15-3.75
20-3.75
20-3.75
25-3.75
25-3.75

30
30
30
40
40
40
40
40
50
50
50
50
50
50
50
60
60
60
60
60
60
60
60
60
80
80
80
80
80
80
80
80
100
100
100
100
100
100
100
100
100
120
120
120
120
120
120

10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
20
20
20
20
20
20
20
20
20
10 or 60
10 or 60
10 or 60
10 or 60
10 or 60
10 or 60
10 or 60
10 or 60
10 or 80
10 or 80
10 or 80
10 or 80
10 or 80
10 or 80
10 or 80
10 or 80
10 or 80
10 or 80
10 or 80
10 or 80
10 or 80
10 or 80
10 or 80

Diameter Number of Turns


through the core Reference
(mm)

30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30

20
20
20
20
20
20
20
20
20
20
30
30
30
30
30
35
35
35
35
35
35
35
35
45
45
45
45
45
45
45
45
50
50
50
50
50
50
50
50
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60

5
3
2
2
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

LMKP6P13020
LMKP6P15020
LMKP6P17520
LMKP6P110020
LMKP6P115020
LMKP6P120020
LMKP6P110030
LMKP6P120030
LMKP6P125030
LMKP6P130030
LMKP6P125040
LMKP6P130040
LMKP6P140040
LMKP6P150040
LMKP6P160040
LMKP6P130050
LMKP6P140050
LMKP6P150050
LMKP6P160050
LMKP6P175050
LMKP6P180050
LMKP6P1100050
LMKP6P1120050
LMKP6P150060
LMKP6P160060
LMKP6P175060
LMKP6P180060
LMKP6P1100060
LMKP6P1120060
LMKP6P1150060
LMKP6P1200060
LMKP6P160080
LMKP6P175080
LMKP6P180080
LMKP6P1100080
LMKP6P1120080
LMKP6P1150080
LMKP6P1200080
LMKP6P1250080
LMKP6P1600100
LMKP6P1750100
LMKP6P1800100
LMKP6P11000100
LMKP6P11200100
LMKP6P11500100
LMKP6P12000100
LMKP6P12500100
LMKP6P13000100
LMKP6P11500120
LMKP6P12000120
LMKP6P12500120
LMKP6P13000120
LMKP6P14000120
LMKP6P15000120

75

RT16 Fuse
Standard: IEC 60269

Function

Description

RT16 fuse provide:


Protection of circuits against overload current
Protection of circuits against short-circuit current

Technical Data
Rate current range:2-630A
Rate voltage:500/660V
Rate breaking capacity:120KA(500V),50KA(660V)

Standard and certification


IEC60269
CE

Overall dimensions

Type

RT16-00

RT16-1

RT16-2

RT16-3

78.5

135

150

150

29

48

58

67

57

62

72

85

49

67

67

67

30

58

64

64

120

200

250

250

C1

61

83

99

105

C2

85

96

112

120

100

175

200

210

25

25

25

25

7.5

10.5

10.5

10.5

30

30

30

76

Delixi Electric

RT16 Fuse
Standard: IEC 60269

Ordering information
Fuse-link Rate current In(A) Suitable fuse bases
RT16-00

RT16-00

Weight(g)
170

RT16004

RT16006

RT16008

10

RT160010

12

RT160012

16

RT160016

20

RT160020

25

RT160025

32

RT160032

40

RT160040

50

RT160050

63

RT160063

80

RT160080

100

RT1600100

125

RT1600125

80

RT1600160
RT16-1

450

RT161100

125

RT161125

160

RT161160

200

RT161200

125

RT161250
RT16-2

660

RT162160

200

RT162200

250

RT162250

300

RT162300

315

RT162315

355

RT162355

315

160

RT162400
RT16-3

850

RT163355

400

RT163400

450

RT163450

500

RT163500

630

RT163630

Material

Weight(g)

Reference

Ceramic

200

RT1600ZT

Resin
RT16-1

250

Ceramic

RT1600ZS
700

Resin
RT16-2

400

Ceramic

630

Ceramic
Resin

Delixi Electric

RT161ZT
RT161ZS

1150

Resin
RT16-3

RT163315

355

Fuse Base Rate current In(A)


RT16-00

RT162125

160

400
RT16-3

RT16180

100

250
RT16-2

RT16002

160
RT16-1

Reference

RT162ZT
RT162ZS

1280

RT163ZT
RT163ZS

77

RT18 Fuse
Standard: IEC 60269

Function

RT18 fuse provide:


Protection of circuits against overload current
Protection of circuits against short-circuit current

Description

Technical Data
Rate current range:2-63A
Rate voltage:380V
Rate breaking capacity:100KA

Standard and certification


IEC60269
CE

Overall dimensions

Cylindrical Fuse
Type

Size

RT18-32

10

38

38

RT18-63

14

51

51 +0.6
-1.0

C
0.6

Hmax

10.3

0.1

10.5

14.3

0.1

13.8

Holder of fuse

78

Type

RT18-32

63

60

79

35

80

18

54

RT18-63

78

76

103

35

110

25

75

Delixi Electric

RT18 Fuse
Standard: IEC 60269

Cylindrical Fuse

Rate current In(A)

Weight(g)

Reference

RT18-32

RT10382

RT10384

RT10386

RT10388

10

RT103810

12

RT103812

16

RT103816

20

RT103820

25

RT103825

32

RT103832

RT18-63

RT14512

20

RT14514

RT14516

RT14518

10

RT145110

12

RT145112

16

RT145116

20

RT145120

25

RT145125

32

RT145132

40

RT145140

50

RT145150

63

RT145163

Holder of fuse Pole Rate current In(A) Note

Weight(g) Reference

RT18-32X

82

1P

32

Material:Resin
Pilotlamp

2P

RT1832Z2XB
RT1832Z3XB

3P
RT18-32

1P

32

Material:Resin

82

Not Pilotlamp

2P
1P

RT1832Z3B
32

Material:Nylon

82

RT1832Z3X

3P
1P

32

Material:Nylon

82

Not Pilotlamp

2P
1P

RT1832Z3
63

Material:Resin

206

RT1863Z3XB

3P
1P
2P
3P

Delixi Electric

RT1863ZXB
RT1863Z2XB

Not Pilotlamp

2P
RT18-63

RT1832Z
RT1832Z2

3P
RT18-63X

RT1832ZX
RT1832Z2X

Pilotlamp

2P
RT18-32

RT1832ZB
RT1832Z2B

3P
RT18-32X

RT1832ZXB

63

Material:Resin
Pilotlamp

206

RT1863ZB
RT1863Z2B
RT1863Z3B

79

JXF Power Distribution Box


Standard: IEC 670.1989, IEC 60439-1

Function

JXF power distribution box provide:


Control,monitoring,measurement and protection
for the electric power lines and the main power control equipment

Description

Technical Data
Rated operating voltage:220V,380V
Rated insulated voltage:400V,660V
Rated operating current:400A
Protection rating:IP30 for complete set,IP43 for box
Instantaneous withstand current:6KA,15KA

Standard and certification


IE670.1989,IEC60439-1

Overall dimensions

cover plate

sealing strip

sealing strip

handle lock
door
peg board

80

box

hinge

Delixi Electric

JXF Power Distribution Box


Standard: IEC 670.1989, IEC 60439-1

Delixi Electric

Dimension
Istallation
dimension
D
H1 B1

Type

Thickness
of iron
Figure
charge
dimension
H
W

JXF-2520/14

1.0

250 200 140 290 150 170 158 1

JXF252014

JXF-3025/14

1.0

300 250 140 340 200 220 208 1

JXF302514

JXF-3025/18

1.0

300 250 180 340 200 220 208 1

JXF302518

JXF-3030/14

1.0

300 300 140 340 250 220 258 1

JXF303014

JXF-3030/18

1.0

300 300 180 340 250 220 258 1

JXF303018

JXF-4030/14

1.0

400 300 140 440 250 320 258 1

JXF403014

JXF-4030/20

1.0

400 300 200 440 250 320 258 1

JXF403020

JXF-5040/14

1.0

500 400 140 540 350 420 358 1

JXF504014

JXF-5040/20

1.0

500 400 200 540 350 420 358 2

JXF504020

JXF-5040/25

1.0

500 400 250 540 350 420 358 2

JXF504025

JXF-6040/14

1.2

600 400 140 640 350 520 358 2

JXF604014

JXF-6040/20

1.2

600 400 200 640 350 520 358 2

JXF604020

JXF-6040/25

1.2

600 400 250 640 350 520 358 2

JXF604025

JXF-6050/14

1.2

600 500 140 640 450 520 458 2

JXF605014

JXF-6050/20

1.2

600 500 200 640 450 520 458 2

JXF605020

JXF-6050/25

1.2

600 500 250 640 450 520 458 2

JXF605025

JXF-7050/16

1.2

700 500 160 740 450 620 458 2

JXF705016

JXF-7050/20

1.2

700 500 200 740 450 620 458 2

JXF705020

JXF-7050/25

1.2

700 500 250 740 450 620 458 2

JXF705025

JXF-8060/20

1.5

800 600 200 840 550 720 558 2

JXF806020

JXF-8060/25

1.5

800 600 250 840 550 720 558 2

JXF806025

JXF-10080/20 1.5

1000 800 200 1040 750 920 758 2

JXF1008020

JXF-10080/25 1.5

1000 800 250 1040 750 920 758 2

JXF1008025

JXF-10080/30 1.5

1000 800 300 1040 750 920 758 2

JXF1008030

Botoom
Number Reference
board
of lock
H6 B6

81

LD11 Series of indicator light


Standard: IEC 60947-5-1

Function

LD11 Series of indicator light provide:


Pilot signal, anticipating signals
Emergency signals and other instructions incidents signal use

Description

Technical data
Rated voltage(V)
Rated current(mA)
Working life(H)
Brightness of light(cd/m2)
Power frequency withstand voltage
Degree of protection

AC/DC
6 12 24 36 48 110 220
50
30000
40
2500V AC 1min
IP65

AC
220 380
20

Standard and certification


IEC 60947-5-1
CE

82

Delixi Electric

LD11 Series of indicator light


Standard: IEC 60947-5-1

Button colour

Rated voltage

Reference

AC.DC 6V

LD1122A21T7

Overall dimensions

Unit:mm

LD1122A21T3
LD1122A21T4
LD1122A21T5
LD1122A21T8
AC.DC 12V

LD1122A21J7
LD1122A21J3
LD1122A21J4
LD1122A21J5
LD1122A21J8

AC.DC 24V

LD1122A21B7
LD1122A21B3
LD1122A21B4
LD1122A21B5
LD1122A21B8

AC.DC 110V

LD1122A21F7
LD1122A21F3
LD1122A21F4
LD1122A21F5
LD1122A21F8

AC.DC 220V

LD1122A21M7
LD1122A21M3
LD1122A21M4
LD1122A21M5
LD1122A21M8

AC 220V

LD1122A41M7
LD1122A41M3
LD1122A41M4
LD1122A41M5
LD1122A41M8

AC 380V

LD1122A41Q7
LD1122A41Q3
LD1122A41Q4
LD1122A41Q5
LD1122A41Q8

AC.DC 6V

LD1122B21T7
LD1122B21T3
LD1122B21T4
LD1122B21T5
LD1122B21T8

AC.DC 12V

LD1122B21J7
LD1122B21J3
LD1122B21J4
LD1122B21J5
LD1122B21J8

AC.DC 24V

LD1122B21B7
LD1122B21B3
LD1122B21B4

Delixi Electric

83

LD11 Series of indicator light


Standard: IEC 60947-5-1

Button colour

Rated voltage

Reference

AC.DC 24V

LD1122B21B5

Overall dimensions

Unit:mm

LD1122B21B8
AC.DC 110V

LD1122B21F7
LD1122B21F3
LD1122B21F4
LD1122B21F5
LD1122B21F8

AC.DC 220V

LD1122B21M7
LD1122B21M3
LD1122B21M4
LD1122B21M5
LD1122B21M8

AC 220V

LD1122B41M7
LD1122B41M3
LD1122B41M4
LD1122B41M5
LD1122B41M8

AC 380V

LD1122B41Q7
LD1122B41Q3
LD1122B41Q4
LD1122B41Q5
LD1122B41Q8

AC.DC 6V

LD1122C21T7
LD1122C21T3
LD1122C21T4
LD1122C21T5
LD1122C21T8

AC.DC 12V

LD1122C21J7
LD1122C21J3
LD1122C21J4
LD1122C21J5
LD1122C21J8

AC.DC 24V

LD1122C21B7
LD1122C21B3
LD1122C21B4
LD1122C21B5
LD1122C21B8

AC 220V

LD1122C41M7
LD1122C41M3
LD1122C41M4
LD1122C41M5
LD1122C41M8

AC 380V

LD1122C41Q7
LD1122C41Q3
LD1122C41Q4
LD1122C41Q5
LD1122C41Q8

84

Delixi Electric

LD11 Series of indicator light


Standard: IEC 60947-5-1

Button colour

Rated voltage

Reference

AC.DC 6V

LD1122D21T7

Overall dimensions

Unit:mm

LD1122D21T3
LD1122D21T4
LD1122D21T5
LD1122D21T8
AC.DC 12V

LD1122D21J7
LD1122D21J3
LD1122D21J4
LD1122D21J5
LD1122D21J8

AC.DC 24V

LD1122D21B7
LD1122D21B3
LD1122D21B4
LD1122D21B5
LD1122D21B8

AC 220V

LD1122D41M7
LD1122D41M3
LD1122D41M4
LD1122D41M5
LD1122D41M8

AC 380V

LD1122D41Q7
LD1122D41Q3
LD1122D41Q4
LD1122D41Q5
LD1122D41Q8

Delixi Electric

85

LAY3 Serie of pushbuttons


Standard: IEC 60947-5-1

Function

LAY3 Serie of Pushbuttons:


Control and signal chain

Description

Technical data
Conventional thermal current(A)
AC-15 Rated operational voltage(V)
Rated operational current(A)
DC-13 Rated operational voltage(V)
Rated operational current(A)
Degree of protection
Degree of pollution
Type of installation
Altitude
Ambient air temperature

10
660
1.5
440
0.1
IP55
3

380
2.5
220
0.3

220
4.5
110
0.6

2000m
-5 ~+40

Standard and certification


IEC 60947-5-1

86

Delixi Electric

LAY3 Serie of pushbuttons


Standard: IEC 60947-5-1

Flush Button
Button colour

Contact blooks

Note

Reference

1NO+1NC

Momentary

LAY311BN4

1NO+1NC

(Non-illuminated)

LAY311BN3

1NO+1NC

LAY311BN2

1NO+1NC

LAY311BN5

1NO+1NC

LAY311BN6

1NO+1NC

LAY311BN1

Overall dimensions

Unit:mm

LAY3 general

Selector Switche-Short Handle


1NO+1NC

Two-position

LAY311X204

1NO+1NC

Maintained

LAY311X203

1NO+1NC

LAY311X202
LAY3-X/2 Selector Swiches

1NO+1NC

Three-position

LAY311X304

1NO+1NC

Maintained

LAY311X303

1NO+1NC

LAY311X302
LAY3-X/3 Selector Swiches

Emergency Stop Pushbutton


1NO+1NC

Maintained

LAY311ZS14

1NO+1NC

LAY311ZS13

1NC

LAY301ZS14

LAY3-ZS/1 Maintained

Flush Buttons Illuminated


1NO+1NC

Incandescent lamp LAY311D4T

1NO+1NC

AC DC 6V

1NO+1NC
1NO+1NC

LAY311D4T
LED AC DC 6V

LAY311D4TL

1NO+1NC

LAY311D3TL

1NO+1NC

LAY311D5TL

1NO+1NC

NEON AC 220V

LAY311D3MN

1NO+1NC

LAY311D5MN
NEON AC 380V

LAY3-D Illuminated

LAY311D4MN

1NO+1NC

1NO+1NC

Delixi Electric

LAY311D3T

LAY311D4QN

1NO+1NC

LAY311D3QN

1NO+1NC

LAY311D5QN

87

LAY7 Serie of pushbuttons


Standard: IEC 60947-5-1

Function

LAY7 Serie of Pushbuttons:


Control and signal chain

Description

Technical data
Conventional thermal current(A)
AC-15 Rated operational voltage(V)
Rated operational current(A)
DC-13 Rated operational voltage(V)
Rated operational current(A)
Degree of protection
Degree of pollution
Type of installation
Altitude
Ambient air temperature

10
660
1.1
440
0.25
IP55
3

380
2.0
220
0.5

220
3.3
110
1

2000m
-5 ~+40

Standard and certification


IEC 60947-5-1
CE

Overall dimensions

Unit:mm

Type

22,
A

25,

30
B
1-2 block
50

3-4 block
70

66

86

48

68

Flush Button Momentary

14

Extended Button Momentary

20

Whole protection cover button

20

Flush Buttons Illuminated

22

Mushroom Pushbutton Illuminated

24.5

Mushroom Pushbutton Non-illuminated

24.5

Flush Button Maintained

14

Extended Button Maintained

20

Mushroom Pushbutton Maintained

24.5

Flush Button Maintained Illuminated

22

66

86

Emergency Stop Pushbutton

24.5

48

48

Selector Swiches-Short Handle

26

Selector Swiches-Long Handle

26

Key-operated Selector Swiches

40

Note: long 37mm, wide A 30mm B 42mm, in the table values is max.

88

Delixi Electric

LAY7 Serie of pushbuttons


Standard: IEC 60947-5-1

Flush Button
Button colour

Contact blooks

Note

Reference

1NO+1NC

Momentary

LAY711BN12

1NO+1NC

(Non-illuminated)

LAY711BN22

1NO+1NC

LAY711BN32

1NO+1NC

LAY711BN42

1NO+1NC

LAY711BN52

1NO+1NC

LAY711BN62

1NO+1NC

Maintained

LAY711BNZS12

1NO+1NC

(Non-illuminated)

LAY711BNZS22

1NO+1NC

LAY711BNZS32

1NO+1NC

LAY711BNZS42

1NO+1NC

LAY711BNZS52

1NO+1NC

LAY711BNZS62

Extended Button
1NO+1NC

Momentary

LAY711GN12

1NO+1NC

(Non-illuminated)

LAY711GN22

1NO+1NC

LAY711GN32

1NO+1NC

LAY711GN42

1NO+1NC

LAY711GN52

1NO+1NC

LAY711GN62

1NO+1NC

Maintained

LAY711GNZS12

1NO+1NC

(Non-illuminated)

LAY711GNZS22

1NO+1NC

LAY711GNZS32

1NO+1NC

LAY711GNZS42

1NO+1NC

LAY711GNZS52

1NO+1NC

LAY711GNZS62

1NO+1NC

LAY711JN12

1NO+1NC

LAY711JN22

1NO+1NC

LAY711JN32

1NO+1NC

LAY711JN42

1NO+1NC

LAY711JN52

1NO+1NC

LAY711JN62

Whole protection cover button

Delixi Electric

89

LAY7 Serie of pushbuttons


Standard: IEC 60947-5-1

Selector Switche-Short Handle


Button colour

Contact blooks

Note

Reference

1NO+1NC

Two-position Maintained

LAY711X2022

1NO+1NC

LAY711X2032

1NO+1NC

LAY711X2042

1NO+1NC

Three-position Maintained

LAY711X3022

1NO+1NC

LAY711X3032

1NO+1NC

LAY711X3042

2NO

LAY720X3022

2NO

LAY720X3032

2NO

LAY720X3042

1NO+1NC

Two-position Right Momentary

LAY711X2122

1NO+1NC

Three-position Right Momentary

LAY711X3122

1NO+1NC

Three-position Right and left Momentary

LAY711X3322

2NO

Three-position Right and left Momentary

LAY720X3322

1NO+1NC

Two-position Maintained

LAY711XB2022

Selector Switche-Long Handle


LAY711XB2032

1NO+1NC

LAY711XB2042

1NO+1NC
1NO+1NC

Three-position Maintained

LAY711XB3022

1NO+1NC

LAY711XB3032

1NO+1NC

LAY711XB3042

2NO

LAY720XB3022

2NO

LAY720XB3032
LAY720XB3042

2NO
1NO+1NC

Two-position Right Momentary

LAY711XB2122

1NO+1NC

Three-position Right Momentary

LAY711XB3122

1NO+1NC

Three-position Right and left Momentary

LAY711XB3322

2NO

Three-position Right and left Momentary

LAY720XB3322

1NO+1NC

Two-position Maintained

LAY711Y2002

1NO+1NC

Three-position Maintained

LAY711Y3002

2NO

Three-position Maintained

LAY720Y3002

1NO+1NC

Two-position Right Momentary

LAY711Y2102

1NO+1NC

Three-position Right Momentary

LAY711Y3102

1NO+1NC

Three-position Right and left Momentary

LAY711Y3302

2NO

Three-position Right and left Momentary

LAY720Y3302

1NO+1NC

Momentary(Non-illuminated)

LAY711M32

Key-operated Selector Swiche

Mushroom Pushbutton
LAY711M42

1NO+1NC

LAY701M42

1NC
1NO+1NC

Momentary(illuminated LED 6V)

1NO+1NC

LAY711DM4T2L

1NO+1NC
1NO+1NC

90

LAY711DM3T2L
LAY711DM5T2L

Maintained(Non-illuminated)

LAY711MZS32

1NO+1NC

LAY711MZS42

1NC

LAY701MZS42
Delixi Electric

LAY7 Serie of pushbuttons


Standard: IEC 60947-5-1

Emergency Stop Pushbutton


Button colour

Contact blooks

Note

Reference

1NO+1NC

LAY711ZS32

1NO+1NC

LAY711ZS42

1NO

LAY710ZS42

Flush Buttons Illuminated


1NO+1NC

Momentary LED 6V

LAY711D3T2L

1NO+1NC

LAY711D4T2L

1NO+1NC

LAY711D5T2L

1NO+1NC
1NO+1NC

LAY711D8T2L
Momentary LED 24V

LAY711D7B2L

1NO+1NC

LAY711D3B2L

1NO+1NC

LAY711D4B2L

1NO+1NC

LAY711D5B2L

1NO+1NC

LAY711D8B2L

1NO+1NC

Momentary LED 220V

LAY711D7M2L

1NO+1NC

LAY711D3M2L

1NO+1NC

LAY711D4M2L

1NO+1NC

LAY711D5M2L

1NO+1NC
1NO+1NC

LAY711D8M2L
Momentary NEON 220V

LAY711D1M2N

1NO+1NC

LAY711D3M2N

1NO+1NC

LAY711D4M2N

1NO+1NC

LAY711D5M2N

1NO+1NC
1NO+1NC

LAY711D6M2N
Momentary NEON 380V

LAY711D1Q2N

1NO+1NC

LAY711D3Q2N

1NO+1NC

LAY711D4Q2N

1NO+1NC

LAY711D5Q2N

1NO+1NC
1NO+1NC

LAY711D6Q2N
Maintained LED 6V

LAY711DZS7T2L

1NO+1NC

LAY711DZS3T2L

1NO+1NC

LAY711DZS4T2L

1NO+1NC

LAY711DZS5T2L

1NO+1NC

LAY711DZS8T2L

1NO+1NC

Delixi Electric

LAY711D7T2L

1NO+1NC

Maintained LED 24V

LAY711DZS7B2L

1NO+1NC

LAY711DZS3B2L

1NO+1NC

LAY711DZS4B2L

1NO+1NC

LAY711DZS5B2L

1NO+1NC

LAY711DZS8B2L

91

LAY7 Serie of pushbuttons


Standard: IEC 60947-5-1

Flush Buttons Illuminated


Button colour

Contact blooks

Note

Reference

1NO+1NC

Maintained LED 220V

LAY711DZS7M2L

1NO+1NC

LAY711DZS3M2L

1NO+1NC

LAY711DZS4M2L

1NO+1NC

LAY711DZS5M2L

1NO+1NC
1NO+1NC

LAY711DZS8M2L
Maintained NEON 220V

LAY711DZS3M2N

1NO+1NC

LAY711DZS4M2N

1NO+1NC

LAY711DZS5M2N

1NO+1NC
1NO+1NC

92

LAY711DZS1M2N

1NO+1NC

LAY711DZS6M2N
Maintained NEON 380V

LAY711DZS1Q2N

1NO+1NC

LAY711DZS3Q2N

1NO+1NC

LAY711DZS4Q2N

1NO+1NC

LAY711DZS5Q2N

1NO+1NC

LAY711DZS6Q2N

Delixi Electric

LAY8 Serie of pushbuttons


Standard: IEC 60947-5-1

Function

LAY8 Serie of Pushbuttons:


Control and signal chain

Description

Technical data
Conventional thermal current(A)
AC-15 Rated operational voltage(V)
Rated operational current(A)
DC-13 Rated operational voltage(V)
Rated operational current(A)
Degree of protection
Degree of pollution
Type of installation
Altitude
Ambient air temperature

10
660
1.5
440
0.2
IP55
3

380
2.5
220
0.4

220
4.5
110
0.8

2000m
-5 ~+40

Standard and certification


IEC 60947-5-1
CE

Delixi Electric

93

LAY8 Serie of pushbuttons


Standard: IEC 60947-5-1

Flush Button
Button colour

Contact blooks

Note

Reference

1NO+1NC

Momentary

LAY811BN1

1NO+1NC

(Non-illuminated)

LAY811BN2

1NO+1NC

LAY811BN3

1NO+1NC

LAY811BN4

1NO+1NC

LAY811BN5

1NO+1NC

LAY811BN6

1NO+1NC

Maintained

LAY811ZS1

1NO+1NC

(Non-illuminated)

LAY811ZS2

1NO+1NC

LAY811ZS3

1NO+1NC

LAY811ZS4

1NO+1NC

LAY811ZS5

1NO+1NC

LAY811ZS6

1NO+1NC

Waterproof

LAY811S1

1NO+1NC

(Non-illuminated)

LAY811S2

1NO+1NC

LAY811S3

1NO+1NC

LAY811S4

1NO+1NC

LAY811S5

1NO+1NC

LAY811S6

Overall dimensions

Unit:mm

Selector Switche-Short Handle


1NO+1NC

Two-position Maintained

1NO+1NC

LAY811X203

1NO+1NC
1NO+1NC

LAY811X202
LAY811X204

Three-position Maintained

LAY811X302

1NO+1NC

LAY811X303

1NO+1NC

LAY811X304

2NO

LAY820X302

1NO+1NC

Two-position Right Momentary

LAY811X312

1NO+1NC

Three-position Right Momentary

LAY811X212

2NO

Three-position Right and left Momentary

LAY820X312

Two-position Maintained

LAY811XB202

Selector Switche-Long Handle


1NO+1NC
1NO+1NC

LAY811XB203

1NO+1NC
1NO+1NC

LAY811XB204
Three-position Maintained

LAY811XB303

1NO+1NC

LAY811XB304

2NO

94

LAY811XB302

1NO+1NC

LAY820XB302

1NO+1NC

Momentary(Non-illuminated)

LAY811XB212

1NO+1NC

Three-position Right Momentary

LAY811XB312

2NO

Three-position Right and left Momentary

LAY820XB332

Delixi Electric

LAY8 Serie of pushbuttons


Standard: IEC 60947-5-1

Mushroom Pushbutton
Button colour

Contact blooks

Note

Reference

1NO+1NC

LAY811M3

1NO+1NC

LAY811M4

Overall dimensions

Unit:mm

Emergency Stop Pushbutton


1NO+1NC

LAY811ZS3

1NO+1NC

LAY811ZS4

1NO

LAY810ZS4

Flush Buttons Illuminated


1NO+1NC

LED AC.DC 6V

LAY811D3T2L

1NO+1NC

LAY811D4T2L

1NO+1NC

LAY811D5T2L

1NO+1NC
1NO+1NC

LAY811D8T2L
LED AC.DC 24V

LAY811D7B2L

1NO+1NC

LAY811D3B2L

1NO+1NC

LAY811D4B2L

1NO+1NC

LAY811D5B2L

1NO+1NC
1NO+1NC

LAY811D8B2L
LED AC.DC 220V

LAY811D7M2L

1NO+1NC

LAY811D3M2L

1NO+1NC

LAY811D4M2L

1NO+1NC

LAY811D5M2L

1NO+1NC

LAY811D8M2L

1NO+1NC

LED AC 220V

LAY811D7M4L

1NO+1NC

LAY811D3M4L

1NO+1NC

LAY811D4M4L

1NO+1NC

LAY811D5M4L

1NO+1NC
1NO+1NC

Delixi Electric

LAY811D7T2L

1NO+1NC

LAY811D8M4L
LED AC 380V

LAY811D7Q4L

1NO+1NC

LAY811D3Q4L

1NO+1NC

LAY811D4Q4L

1NO+1NC

LAY811D5Q4L

1NO+1NC

LAY811D8Q4L

95

72 Series Pannel Meter


Standard: IEC 51-1~9

Function

72 series pannel meter provide:


Measuring current,voltage
Measuring frequency,power,power factor

Description
Pressure test
Voltage:2000V
Frequency:50Hz/60Hz
Duration:1min

Tolerance mechanical impact:max 147m/s2


Response time: 4s
Pointer deflection angle:90

Standard and certification


IEC 51-1~9
CE

Overall dimensions
Unit:mm

96

Delixi Electric

72 Series Pannel Meter


Standard: IEC 51-1~9

Ordering information
Type

Accuracy Specification
rating

Note

Shape(mm)

Ammeter

1.5

30/5A

AC Type

72

72

67.5

72TA30

40/5A

External connection 72

72

67.5

72TA40

50/5A

transformer

72

72

67.5

72TA50

60/5A

2 times of current

72

72

67.5

72TA60

75/5A

overload

72

72

67.5

72TA75

80/5A

72

72

67.5

72TA80

100/5A

72

72

67.5

72TA100

150/5A

72

72

67.5

72TA150

160/5A

72

72

67.5

72TA160

200/5A

72

72

67.5

72TA200

250/5A

72

72

67.5

72TA250

300/5A

72

72

67.5

72TA300

400/5A

72

72

67.5

72TA400

600/5A

72

72

67.5

72TA600

800/5A

72

72

67.5

72TA800

1000/5A

72

72

67.5

72TA1000

1600/5A

72

72

67.5

72TA1600

5000/5A

72

72

67.5

72TA5000

10000/5A

72

72

67.5

72TA10000

72

72

67.5

72TA5A

5A

AC Type

Reference

Direct connection
2.5

15A

AC Type

72

72

67.5

72TA15A

20A

Direct connection

72

72

67.5

72TA20A

25A

2 times of current

72

72

67.5

72TA25A

30A

overload

72

72

67.5

72TA30A

40A

72

72

67.5

72TA40A

50A

72

72

67.5

72TA50A

60A

72

72

67.5

72TA60A

80A

72

72

67.5

72TA80A

72

72

67.5

72TA100A

1.5

5A

DC Type

72

72

67.5

72C1A5A

1.5

300V

AC Type

72

72

67.5

72TV300

72

72

67.5

72TV500

100A
Voltmerer

500V

72

72

67.5

72TV600

500V

DC Type

72

72

67.5

72C1V500

45-55HZ (200V)

AC Type

72

72

67.5

72TZ200

600V
Frequency meter

1.0

Delixi Electric

97

96 Series Pannel Meter


Standard: IEC 51-1~9

Function

96 series pannel meter provide:


Measuring current,voltage
Measuring frequency,power,power factor

Description
Pressure test
Voltage:2000V
Frequency:50Hz/60Hz
Duration:1min

Tolerance mechanical impact:max 147m/s2


Response time: 4s
Pointer deflection angle:90

Standard and certification


IEC 51-1~9
CE

Overall dimensions
Unit:mm

98

Delixi Electric

96 Series Pannel Meter


Standard: IEC 51-1~9

Ordering information
Type

Accuracy Specification
rating

Note

Shape(mm)

Ammeter

1.5

30/5A

AC Type

96

96

67.5 96TA30

40/5A

External connection 96
transformer
96

96

67.5 96TA40

50/5A

96

67.5 96TA50

60/5A

96

96

67.5 96TA60

75/5A

96

96

67.5 96TA75

80/5A

96

96

67.5 96TA80

100/5A

96

96

67.5 96TA100

150/5A

96

96

67.5 96TA150

160/5A

96

96

67.5 96TA160

200/5A

96

96

67.5 96TA200

250/5A

96

96

67.5 96TA250

300/5A

96

96

67.5 96TA300

400/5A

96

96

67.5 96TA400

600/5A

96

96

67.5 96TA600

800/5A

96

96

67.5 96TA800

1000/5A

96

96

67.5 96TA1000

1600/5A

96

96

67.5 96TA1600

5000/5A

96

96

67.5 96TA5000

10000/5A

96

96

67.5 96TA10000

96

96

67.5 96TA5A

5A

AC Type

Reference

Direct connection
2.5

15A

AC Type

96

96

67.5 96TA15A

20A

Direct connection

96

96

67.5 96TA20A

25A

96

96

67.5 96TA25A

30A

96

96

67.5 96TA30A

40A

96

96

67.5 96TA40A

50A

96

96

67.5 96TA50A

60A

96

96

67.5 96TA60A

80A

96

96

67.5 96TA80A

96

96

67.5 96TA100A

1.5

5A

DC Type

96

96

67.5 96C1A5A

1.5

300V

AC Type

96

96

67.5 96TV300

96

96

67.5 96TV500

100A
Voltmerer

500V

96

96

67.5 96TV600

500V

DC Type

96

96

67.5 96C1V500

45-55HZ (200V)

AC Type

96

96

67.5 96TZ200

600V
Frequency meter

Delixi Electric

1.0

99

TND Voltage Stabilizer

Function

TND voltage stabilizer provide:


Control system consist of linear integrated circuit
automaticly control voltage regulation
Timelag, overvoltage and undervoltage protection

Description

Technical Data
Type

TND0.5kVA~5kVA
Voltage regulation accuracy

Output voltage Undervoltage protection


Overvoltage protection

220

4%,110

4%

TND7kVA~30kVA
220

4%

184V 4V(set up according to the customers request)


246V

4V

Phase

single-phase

Input voltage range

160V~240V

Efficiency

>90%

Voltage regulation speed

<1s(when input voltage change 10%)

Temperature rise

<60

Frequency

50Hz/60Hz

Enviroment temperature,relative temperature

-50

Waveform distortion
Rated maximum output current(A)

no additional distortion
2(500VA),4(1000VA),6(1500VA),8(2000VA),12(3000VA),
20(5000VA),25(7000VA),40(10KVA),85(15KVA),
73(20KVA),109(30KVA)

Withstand voltage

1500V/1min

(full range)
~40

below 90%

Overall dimensions

unit: mm

Product shape

Model

Wide

Length

Desktop

TND-0.5

190

160

135

TND-1

205

190

155

TND-1.5

205

190

155

TND-2

240

270

200

TND-3

225

305

235

TND-5

225

310

290

TND-7

240

387

360

TND-10

240

387

360

TND-10

310

340

535

TND-15

340

360

640

TND-20

340

380

780

TND30

425

390

845

Cabinet type

100

Hight

Delixi Electric

TND Voltage Stabilizer

Ordering information
Product shape
Desktop

Cabinet type

Delixi Electric

Power rating

Referencce

0.5K

TNDP5

1K

TND1

1.5K

TND1P5

2K

TND2

3K

TND3

5K

TND5

7K

TND7

10K

TND10

10K

TND10G

15K

TND15G

20K

TND20G

30K

TND30G

101

Nylon Cable Ties Series

Description

Technical Data
Material:

Color:

Using nylon 66 material that recognized by UL


Fire-protection rating:94V-2
Acid and erosion control,insulate well and difficult to aging
White, black and other colors

Overall dimensions
Long
INCH

102

MM

MAX.Bundle Tensile Strength Packing


Width DIA(mm)
(root)
LBS
KGS

Reference

2.4"

60

2.5

2-11

18

100

DAR205060**

3.2"

80

2.5

2-16

18

100

DAR205080**

4"

100

2.5

2-22

18

100

DAR205100**

4.7"

120

2.5

2-30

18

100

DAR205120**

6"
12"

150
200

2.5
2.5

2-35
3-80

18
18

8
8

100
100

DAR205150**
DAR205200**

4.7"

120

3.6

2-30

40

18

100

DAR306120**

6"

150

3.6

2-35

40

18

100

DAR306150**

7.1"

180

3.6

3-42

40

18

100

DAR306180**

8"

200

3.6

3-50

40

18

100

DAR306200**

10"
12"

250
300

3.6
3.6

3-65
3-80

40
40

18
18

100
100

DAR306250**
DAR306300**

14.6"

370

3.6

3-80

40

18

100

DAR306370**

7.1"

180

4.8

3-42

50

22

100

DAR408180**

8"

200

4.8

3-50

50

22

100

DAR408200**

10"

250

4.8

3-65

50

22

100

DAR408250**

12"
14"

300
350

4.8
4.8

3-80
3-90

50
50

22
22

100
100

DAR408300**
DAR408350**

15"

380

4.8

3-102

50

22

100

DAR408380**

16"

400

4.8

3-105

50

22

100

DAR408400**

17.7"

450

4.8

3-130

50

22

100

DAR408450**

19.7"

500

4.8

3-150

50

22

100

DAR408500**

8"
10"

200
250

7.2
7.2

3-50
3-65

120
120

55
55

100
100

DAR702200**
DAR702250**

12"

300

7.2

4-80

120

55

100

DAR702300**

14"

350

7.2

4-90

120

55

100

DAR702350**

16"

400

7.2

4-105

120

55

100

DAR702400**

20"

500

7.2

4-150

120

55

100

DAR702500**

30"
18"

750
450

7.2
9

10-220
8-118

120
175

55
80

100
100

DAR702750**
DAR900450**

20"

500

8-150

175

80

100

DAR900500**

21.6"

550

8-160

175

80

100

DAR900550**

27.5"

700

10-205

175

80

100

DAR900700**

32"

800

10-230

175

80

100

DAR900800**

2.4"
3.2"

60
80

2.2
2.2

2-11
2-16

18
18

8
8

100
100

DAR202060**
DAR202080**

4"

100

2.2

2-22

18

100

DAR202100**

4.7"

120

2.2

2-30

18

100

DAR202120**

6"

150

2.2

2-35

18

100

DAR202150**

8"

200

2.2

3-50

18

100

DAR202200**

4.7"
6"

120
150

3.2
3.2

3-30
3-35

40
40

18
18

100
100

DAR302120**
DAR302150**

Delixi Electric

Nylon Cable Ties Series

Long
INCH

Normal Packing

Hang tag Packing

Delixi Electric

MM

Width

MAX.Bundle Tensile Strength Packing Reference


(root)
DIA(mm)
LBS
KGS

7"

180

3.2

3-42

40

18

100

DAR302180

8"

200

3.2

3-50

40

18

100

DAR302200

10"

250

3.2

3-65

40

18

100

DAR302250

12"

300

3.2

3-80

40

18

100

DAR302300

14"

350

3.2

3-90

40

18

100

DAR302350

4.7"

120

4.2

3-30

50

22

100

DAR402120

6"

150

4.2

3-35

50

22

100

DAR402150

7.1"

180

4.2

3-42

50

22

100

DAR402180

8"

200

4.2

3-50

50

22

100

DAR402200

10"

250

4.2

3-65

50

22

100

DAR402250

12"

300

4.2

3-80

50

22

100

DAR402300

14"

350

4.2

3-90

50

22

100

DAR402350

16"

400

4.2

3-105

50

22

100

DAR402400

8"

200

6.5

3-50

120

55

100

DAR605200

10"

250

6.5

3-65

120

55

100

DAR605250

12"

300

6.5

4-80

120

55

100

DAR605300

14"

350

6.5

4-90

120

55

100

DAR605350

16"

400

6.5

4-105

120

55

100

DAR605400

17.7"

450

6.5

3-130

120

55

100

DAR605450

19.7"

500

6.5

4-150

120

55

100

DAR605500

21.6"

550

6.5

4-165

120

55

100

DAR605550

24"

600

6.5

4-170

120

55

100

DAR605600

Note:"

" express color and packing code

Color

Black

White

Blue

Red

Yellow

Green

Normal Packing

BB

WB

UB

RB

YB

GB

Hang tag Packing

BL

WL

UL

RL

YL

GL

103

Power Distribution and Industry Control Product

CDW7

CDM1

JXF
CDC17

CDM1

CDM1L

CDPZ50

CDB6a

Building

CDR17

CDY1

LAY3

DDS607

CDB6LE

Industry

LMK

Energy

Residential

72

DELIXI ELECTRIC LTD.


ADD: DELIXI LIUSHI INDUSTRIAL PARK, YUEQING, ZHEJIANG, P.R.CHINA
POST CODE: 325604
Http://english.delixi-electric.com

Вам также может понравиться