Вы находитесь на странице: 1из 28

BSC3119

Nokia BSC/TCSM, Rel. S12, Product


Documentation, v.1

29 Drop Call Breakdown


Observation

DN0481217
Issue 2-0 en

# Nokia Corporation

1 (28)

29 Drop Call Breakdown Observation

The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This document is intended for the use
of Nokia's customers only for the purposes of the agreement under which the document is
submitted, and no part of it may be reproduced or transmitted in any form or means without the
prior written permission of Nokia. The document has been prepared to be used by professional
and properly trained personnel, and the customer assumes full responsibility when using it.
Nokia welcomes customer comments as part of the process of continuous development and
improvement of the documentation.
The information or statements given in this document concerning the suitability, capacity, or
performance of the mentioned hardware or software products cannot be considered binding but
shall be defined in the agreement made between Nokia and the customer. However, Nokia has
made all reasonable efforts to ensure that the instructions contained in the document are
adequate and free of material errors and omissions. Nokia will, if necessary, explain issues
which may not be covered by the document.
Nokia's liability for any errors in the document is limited to the documentary correction of errors.
NOKIA WILL NOT BE RESPONSIBLE IN ANY EVENT FOR ERRORS IN THIS DOCUMENT
OR FOR ANY DAMAGES, INCIDENTAL OR CONSEQUENTIAL (INCLUDING MONETARY
LOSSES), that might arise from the use of this document or the information in it.
This document and the product it describes are considered protected by copyright according to
the applicable laws.
NOKIA logo is a registered trademark of Nokia Corporation.
Other product names mentioned in this document may be trademarks of their respective
companies, and they are mentioned for identification purposes only.
Copyright Nokia Corporation 2007. All rights reserved.

2 (28)

# Nokia Corporation

DN0481217
Issue 2-0 en

Contents

Contents
Contents 3
List of tables 4
List of figures 5
Summary of changes 7
1

29 Drop Call Breakdown Observation 9

Counters of Drop Call Breakdown Observation 13

DN0481217
Issue 2-0 en

# Nokia Corporation

3 (28)

29 Drop Call Breakdown Observation

List of tables

4 (28)

Table 1.

Measurement description of Drop Call Breakdown Observation

Table 2.

Counters of Drop Call Breakdown Observation

# Nokia Corporation

10

DN0481217
Issue 2-0 en

List of figures

List of figures

DN0481217
Issue 2-0 en

# Nokia Corporation

5 (28)

29 Drop Call Breakdown Observation

6 (28)

# Nokia Corporation

DN0481217
Issue 2-0 en

Summary of changes

Summary of changes

Changes between document issues are cumulative. Therefore, the latest document
issue contains all changes made to previous issues.

Changes made between issues 2 and 12


Updated fields of all counters have been updated.

Changes made between issues 12 and 11


New counter 029041 has been added.

Changes made between issues 11 and 1


New counters 029007-029040 have been added and counters 029000-029006
have been updated.

DN0481217
Issue 2-0 en

# Nokia Corporation

7 (28)

29 Drop Call Breakdown Observation

8 (28)

# Nokia Corporation

DN0481217
Issue 2-0 en

29 Drop Call Breakdown Observation

29 Drop Call Breakdown Observation


Drop Call Breakdown observation collects statistics on the dropped calls. The
detailed data of drop is collected when the drop occurs after the
ASSIGNMENT_COMPLETE message. The focus of the observation can be
either the breakdown of counter DROP AFTER TCH ASSIGN or the breakdown
of counter CLEAR REQUEST SENT BY BSC ON TCH.
If the focus of the observation is breakdown of DROP AFTER TCH ASSIGN, the
observation data is reported when the TCH drop occurred between messages
ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/MSC. If
the focus of the observation is breakdown of CLEAR REQUEST SENT BY BSC
ON TCH, the observation data is reported when CLEAR_REQUEST message is
sent to MSC between the ASSIGNMENT_COMPLETE from BTS and
CLEAR_COMMAND from MSC messages.
The observation is activated on BSC level and drops are recorded per TRX. The
Drop Call Breakdown Observation data is stored to an observation report disk file
and sent to NetAct in an observation file.
Drop Call Breakdown Observation is optional.
Measurement description

Table 1.

Measurement description of Drop Call Breakdown Observation

Measurement

Drop Call Breakdown Observation

Measurement ID

29

Measurement abbreviation

DC_BREAK

Product

BSC

Product software release

S11.5

Target name

Target description

DN0481217
Issue 2-0 en

# Nokia Corporation

9 (28)

29 Drop Call Breakdown Observation

Measurement counters

Table 2.

10 (28)

Counters of Drop Call Breakdown Observation

Counter

Counter number

BTS ID

029000

RELEASE TIME

029001

PHASE OUT

029002

CAUSE OUT

029003

TRX ID

029004

PHASE IN

029005

CAUSE IN

029006

TIMING ADVANCE

029007

DL RX LEVEL

029008

UL RX LEVEL

029009

DL RX QUALITY

029010

UL RX QUALITY

029011

DL FER

029012

UL FER

029013

DL LAST USED BITRATE

029014

UL LAST USED BITRATE

029015

SUDDEN DROP

029016

ADJ CELL PLMN ID 1

029017

ADJ CELL LAC 1

029018

ADJ CELL ID 1

029019

RX LEVEL ADJ 1

029020

ADJ CELL PLMN ID 2

029021

ADJ CELL LAC 2

029022

ADJ CELL ID 2

029023

RX LEVEL ADJ 2

029024

ADJ CELL PLMN ID 3

029025

ADJ CELL LAC 3

029026

ADJ CELL ID 3

029027

RX LEVEL ADJ 3

029028

ADJ CELL PLMN ID 4

029029

# Nokia Corporation

DN0481217
Issue 2-0 en

29 Drop Call Breakdown Observation

Table 2.

Counters of Drop Call Breakdown Observation (cont.)

ADJ CELL LAC 4

029030

ADJ CELL ID 4

029031

RX LEVEL ADJ 4

029032

ADJ CELL PLMN ID 5

029033

ADJ CELL LAC 5

029034

ADJ CELL ID 5

029035

RX LEVEL ADJ 5

029036

ADJ CELL PLMN ID 6

029037

ADJ CELL LAC 6

029038

ADJ CELL ID 6

029039

RX LEVEL ADJ 6

029040

FOCUS OF BREAKDOWN

029041

Related topics

DN0481217
Issue 2-0 en

Counters of Drop Call Breakdown Observation

BSC Statistics Administration

BSC Measurement Counters Displaying Program (FOXMEA)

Performance Measurements

Call Related DX Causes in BSC

Drop Call Breakdown Observation

# Nokia Corporation

11 (28)

29 Drop Call Breakdown Observation

12 (28)

# Nokia Corporation

DN0481217
Issue 2-0 en

Counters of Drop Call Breakdown Observation

Counters of Drop Call Breakdown


Observation

Number

029000

Name

BTS ID

Release

S11.5

Description

Identification of the BTS where the drop occurred.

Updated

When the TCH drop occured between messages


ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or between messages ASSIGNMENT_COMPLETE from BTS
and CLEAR_COMMAND from MSC.

Dependencies with other counters/ 001202 - DROP AFTER TCH ASSIGN


PI(s)
Logical type

Variable

Unit

Integer number

Number

029001

Name

RELEASE TIME

Release

S11.5

Description

Timestamp of the call release (dropped call).


Coded in BCD (Binary Coded Decimal)
Hundredths of seconds : byte
Seconds : byte
Minutes : byte
Hours : byte
Day : byte
Month : byte
Year : word

Updated

DN0481217
Issue 2-0 en

When the TCH drop occured between messages


ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or between messages ASSIGNMENT_COMPLETE from BTS
and CLEAR_COMMAND from MSC.

# Nokia Corporation

13 (28)

29 Drop Call Breakdown Observation

Number

029001

Name

RELEASE TIME

Release

S11.5

Dependencies with other counters/ 001202 - DROP AFTER TCH ASSIGN


PI(s)
Logical type

Variable

Unit

Integer number

Number

029002

Name

PHASE OUT

Release

S11.5

Description

BSC internal phase value of the call release (the phase of the call
where the drop occurred). See Call Related DX Causes in BSC.

Updated

When the TCH drop occured between messages


ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or between messages ASSIGNMENT_COMPLETE from BTS
and CLEAR_COMMAND from MSC.

Dependencies with other counters/ 001202 - DROP AFTER TCH ASSIGN


PI(s)
Logical type

Variable

Unit

Integer number

Number

029003

Name

CAUSE OUT

Release

S11.5

Description

BSC internal cause value of the call release (the drop cause). See
Call Related DX Causes in BSC.

Updated

When the TCH drop occured between messages


ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or between messages ASSIGNMENT_COMPLETE from BTS
and CLEAR_COMMAND from MSC.

Dependencies with other counters/ 001202 - DROP AFTER TCH ASSIGN


PI(s)
Logical type

Variable

Unit

Integer number

14 (28)

# Nokia Corporation

DN0481217
Issue 2-0 en

Counters of Drop Call Breakdown Observation

Number

029004

Name

TRX ID

Release

S11.5

Description

Identification of the TRX where the drop occurred.

Updated

When the TCH drop occured between messages


ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or between messages ASSIGNMENT_COMPLETE from BTS
and CLEAR_COMMAND from MSC.

Dependencies with other counters/ 001202 - DROP AFTER TCH ASSIGN


PI(s)
Logical type

Variable

Unit

Integer number

Number

029005

Name

PHASE IN

Release

S11.5

Description

BSC internal phase value of the call establishment. See Call Related
DX Causes in BSC.

Updated

When the TCH drop occured between messages


ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or between messages ASSIGNMENT_COMPLETE from BTS
and CLEAR_COMMAND from MSC.

Dependencies with other counters/ 001202 - DROP AFTER TCH ASSIGN


PI(s)
Logical type

Variable

Unit

Integer number

Number

029006

Name

CAUSE IN

Release

S11.5

Description

BSC internal cause value of the call establishment. See Call Related
DX Causes in BSC.

Updated

When the TCH drop occured between messages


ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or between messages ASSIGNMENT_COMPLETE from BTS
and CLEAR_COMMAND from MSC.

Dependencies with other counters/ 001202 - DROP AFTER TCH ASSIGN


PI(s)
Logical type

Variable

Unit

Integer number

DN0481217
Issue 2-0 en

# Nokia Corporation

15 (28)

29 Drop Call Breakdown Observation

Number

029007

Name

TIMING ADVANCE

Release

S11.5

Description

Downlink timing advance.

Updated

The timing advance value is an average from the last 4 (four) MS


reports received before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and CLEAR_COMMAND from
MSC.

Logical type

Average

Unit

Integer number

Number

029008

Name

DL RX LEVEL

Release

S11.5

Description

Downlink signal strength.

Updated

The DL RX level value is an average from the last 4 (four) MS


reports received before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and CLEAR_COMMAND from
MSC.

Logical type

Average

Unit

Integer number

Number

029009

Name

UL RX LEVEL

Release

S11.5

Description

Uplink signal strength of the serving cell.

Updated

The UL RX level value is an average from the last 4 (four) MS


reports received before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and CLEAR_COMMAND from
MSC.

Logical type

Average

Unit

Integer number

16 (28)

# Nokia Corporation

DN0481217
Issue 2-0 en

Counters of Drop Call Breakdown Observation

Number

029010

Name

DL RX QUALITY

Release

S11.5

Description

Downlink bit error rate value of the serving cell.

Updated

The DL RX quality value is an average from the last 4 (four) MS


reports received before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and CLEAR_COMMAND from
MSC.

Logical type

Average

Unit

Integer number

Number

029011

Name

UL RX QUALITY

Release

S11.5

Description

Uplink bit error rate value of the serving cell.

Updated

The UL RX quality value is an average from the last 4 (four) MS


reports received before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and CLEAR_COMMAND from
MSC.

Logical type

Average

Unit

Integer number

Number

029012

Name

DL FER

Release

S11.5

Description

Downlink frame erasure value of the serving cell.

Updated

The DL FER value is an average from the last 4 (four) MS reports


received before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and CLEAR_COMMAND from
MSC.

Logical type

Average

Unit

Integer number

DN0481217
Issue 2-0 en

# Nokia Corporation

17 (28)

29 Drop Call Breakdown Observation

Number

029013

Name

UL FER

Release

S11.5

Description

Uplink frame erasure value of the serving cell.

Updated

The UL FER value is an average from the last 4 (four) MS reports


received before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and CLEAR_COMMAND from
MSC.

Logical type

Average

Unit

Integer number

Number

029014

Name

DL LAST USED BITRATE

Release

S11.5

Description

The last bit rate used in downlink direction when the TCH drop
occurred.
Values:
0x05 = AMR HR speech, 7.4 kbit/s
0x06 = AMR HR speech, 6.7 kbit/s
0x07 = AMR HR speech, 5.9 kbit/s
0x08 = AMR HR speech, 5.15 kbit/s
0x09 = AMR HR speech, 4.75 kbit/s
0x0A = AMR FR speech, 12.2 kbit/s
0x0B = AMR FR speech, 10.2 kbit/s
0x0C = AMR FR speech, 7.95 kbit/s
0x0D = AMR FR speech, 7.4 kbit/s
0x0E = AMR FR speech, 6.7 kbit/s
0x0F = AMR FR speech, 5.9 kbit/s
0x10 = AMR FR speech, 5.15 kbit/s
0x11 = AMR FR speech, 4.75 kbit/s.

Updated

When the TCH drop occured between messages


ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or between messages ASSIGNMENT_COMPLETE from BTS
and CLEAR_COMMAND from MSC.

Logical type

Variable

Unit

Integer number

18 (28)

# Nokia Corporation

DN0481217
Issue 2-0 en

Counters of Drop Call Breakdown Observation

Number

029015

Name

UL LAST USED BITRATE

Release

S11.5

Description

The last bit rate used in uplink direction when the TCH drop
occurred.
Values:
0x05 = AMR HR speech, 7.4 kbit/s
0x06 = AMR HR speech, 6.7 kbit/s
0x07 = AMR HR speech, 5.9 kbit/s
0x08 = AMR HR speech, 5.15 kbit/s
0x09 = AMR HR speech, 4.75 kbit/s
0x0A = AMR FR speech, 12.2 kbit/s
0x0B = AMR FR speech, 10.2 kbit/s
0x0C = AMR FR speech, 7.95 kbit/s
0x0D = AMR FR speech, 7.4 kbit/s
0x0E = AMR FR speech, 6.7 kbit/s
0x0F = AMR FR speech, 5.9 kbit/s
0x10 = AMR FR speech, 5.15 kbit/s
0x11 = AMR FR speech, 4.75 kbit/s

Updated

When the TCH drop occured between messages


ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or between messages ASSIGNMENT_COMPLETE from BTS
and CLEAR_COMMAND from MSC.

Logical type

Variable

Unit

Integer number

Number

029016

Name

SUDDEN DROP

Release

S11.5

Description

This counter indicates whether the last 4 (four) MS reports have


been completely lost or not.
Values:
0 = at least 1 (one) of the last 4 (four) MS reports have been
received at least partly.
1 = all of the last 4 (four) MS reports are completely missing.
Counters 029007-029015 and 029017-029040 are updated with the
values from the last received MS report whenever this counter is
updated with value 1.

DN0481217
Issue 2-0 en

# Nokia Corporation

19 (28)

29 Drop Call Breakdown Observation

Number

029016

Name

SUDDEN DROP

Release

S11.5

Updated

When the TCH drop occured between messages


ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or between messages ASSIGNMENT_COMPLETE from BTS
and CLEAR_COMMAND from MSC.

Logical type

Variable

Unit

Integer number

Number

029017

Name

ADJ CELL PLMN ID 1

Release

S11.5

Description

PLMN ID of the strongest adjacent cell.

Updated

The PLMN ID value is based on the last received MS report before


the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and CLEAR_COMMAND from
MSC.

Logical type

Variable

Unit

Integer number

Number

029018

Name

ADJ CELL LAC 1

Release

S11.5

Description

LAC of the strongest adjacent cell.

Updated

The LAC value is based on the last received MS report before the
TCH drop occured between messages ASSIGNMENT_COMPLETE
from BTS and DISCONNECT from MS/MSC or before the TCH drop
occured between messages ASSIGNMENT_COMPLETE from BTS
and CLEAR_COMMAND from MSC.

Logical type

Variable

Unit

Integer number

20 (28)

# Nokia Corporation

DN0481217
Issue 2-0 en

Counters of Drop Call Breakdown Observation

Number

029019

Name

ADJ CELL ID 1

Release

S11.5

Description

Cell ID of the strongest adjacent cell.

Updated

The Cell ID value is based on the last received MS report before the
TCH drop occured between messages ASSIGNMENT_COMPLETE
from BTS and DISCONNECT from MS/MSC or before the TCH drop
occured between messages ASSIGNMENT_COMPLETE from BTS
and CLEAR_COMMAND from MSC.

Logical type

Variable

Unit

Integer number

Number

029020

Name

RX LEVEL ADJ 1

Release

S11.5

Description

RX level value of the strongest adjacent cell.

Updated

The RX level value is based on the last received MS report before


the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and CLEAR_COMMAND from
MSC.

Logical type

Variable

Unit

Integer number

Number

029021

Name

ADJ CELL PLMN ID 2

Release

S11.5

Description

PLMN ID of the 2nd strongest adjacent cell.

Updated

The PLMN ID value is based on the last received MS report before


the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and CLEAR_COMMAND from
MSC.

Logical type

Variable

Unit

Integer number

DN0481217
Issue 2-0 en

# Nokia Corporation

21 (28)

29 Drop Call Breakdown Observation

Number

029022

Name

ADJ CELL LAC 2

Release

S11.5

Description

LAC of the 2nd strongest adjacent cell.

Updated

The LAC value is based on the last received MS report before the
TCH drop occured between messages ASSIGNMENT_COMPLETE
from BTS and DISCONNECT from MS/MSC or before the TCH drop
occured between messages ASSIGNMENT_COMPLETE from BTS
and CLEAR_COMMAND from MSC.

Logical type

Variable

Unit

Integer number

Number

029023

Name

ADJ CELL ID 2

Release

S11.5

Description

Cell ID of the 2nd strongest adjacent cell.

Updated

The Cell ID value is based on the last received MS report before the
TCH drop occured between messages ASSIGNMENT_COMPLETE
from BTS and DISCONNECT from MS/MSC or before the TCH drop
occured between messages ASSIGNMENT_COMPLETE from BTS
and CLEAR_COMMAND from MSC.

Logical type

Variable

Unit

Integer number

Number

029024

Name

RX LEVEL ADJ 2

Release

S11.5

Description

RX level value of the 2nd strongest adjacent cell.

Updated

The RX level value is based on the last received MS report before


the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and CLEAR_COMMAND from
MSC.

Logical type

Variable

Unit

Integer number

22 (28)

# Nokia Corporation

DN0481217
Issue 2-0 en

Counters of Drop Call Breakdown Observation

Number

029025

Name

ADJ CELL PLMN ID 3

Release

S11.5

Description

PLMN ID of the 3rd strongest adjacent cell.

Updated

The PLMN ID value is based on the last received MS report before


the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and CLEAR_COMMAND from
MSC.

Logical type

Variable

Unit

Integer number

Number

029026

Name

ADJ CELL LAC 3

Release

S11.5

Description

LAC of the 3rd strongest adjacent cell.

Updated

The LAC value is based on the last received MS report before the
TCH drop occured between messages ASSIGNMENT_COMPLETE
from BTS and DISCONNECT from MS/MSC or before the TCH drop
occured between messages ASSIGNMENT_COMPLETE from BTS
and CLEAR_COMMAND from MSC.

Logical type

Variable

Unit

Integer number

Number

029027

Name

ADJ CELL ID 3

Release

S11.5

Description

Cell ID of the 3rd strongest adjacent cell.

Updated

The Cell ID value is based on the last received MS report before the
TCH drop occured between messages ASSIGNMENT_COMPLETE
from BTS and DISCONNECT from MS/MSC or before the TCH drop
occured between messages ASSIGNMENT_COMPLETE from BTS
and CLEAR_COMMAND from MSC.

Logical type

Variable

Unit

Integer number

DN0481217
Issue 2-0 en

# Nokia Corporation

23 (28)

29 Drop Call Breakdown Observation

Number

029028

Name

RX LEVEL ADJ 3

Release

S11.5

Description

RX level value of the 3rd strongest adjacent cell.

Updated

The RX level value is based on the last received MS report before


the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and CLEAR_COMMAND from
MSC.

Logical type

Variable

Unit

Integer number

Number

029029

Name

ADJ CELL PLMN ID 4

Release

S11.5

Description

PLMN ID of the 4th strongest adjacent cell.

Updated

The PLMN ID value is based on the last received MS report before


the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and CLEAR_COMMAND from
MSC.

Logical type

Variable

Unit

Integer number

Number

029030

Name

ADJ CELL LAC 4

Release

S11.5

Description

LAC of the 4th strongest adjacent cell.

Updated

The LAC value is based on the last received MS report before the
TCH drop occured between messages ASSIGNMENT_COMPLETE
from BTS and DISCONNECT from MS/MSC or before the TCH drop
occured between messages ASSIGNMENT_COMPLETE from BTS
and CLEAR_COMMAND from MSC.

Logical type

Variable

Unit

Integer number

24 (28)

# Nokia Corporation

DN0481217
Issue 2-0 en

Counters of Drop Call Breakdown Observation

Number

029031

Name

ADJ CELL ID 4

Release

S11.5

Description

Cell ID of the 4th strongest adjacent cell.

Updated

The Cell ID value is based on the last received MS report before the
TCH drop occured between messages ASSIGNMENT_COMPLETE
from BTS and DISCONNECT from MS/MSC or before the TCH drop
occured between messages ASSIGNMENT_COMPLETE from BTS
and CLEAR_COMMAND from MSC.

Logical type

Variable

Unit

Integer number

Number

029032

Name

RX LEVEL ADJ 4

Release

S11.5

Description

RX level value of the 4th strongest adjacent cell.

Updated

The RX level value is based on the last received MS report before


the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and CLEAR_COMMAND from
MSC.

Logical type

Variable

Unit

Integer number

Number

029033

Name

ADJ CELL PLMN ID 5

Release

S11.5

Description

PLMN ID of the 5th strongest adjacent cell.

Updated

The PLMN ID value is based on the last received MS report before


the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and CLEAR_COMMAND from
MSC.

Logical type

Variable

Unit

Integer number

DN0481217
Issue 2-0 en

# Nokia Corporation

25 (28)

29 Drop Call Breakdown Observation

Number

029034

Name

ADJ CELL LAC 5

Release

S11.5

Description

LAC of the 5th strongest adjacent cell.

Updated

The LAC value is based on the last received MS report before the
TCH drop occured between messages ASSIGNMENT_COMPLETE
from BTS and DISCONNECT from MS/MSC or before the TCH drop
occured between messages ASSIGNMENT_COMPLETE from BTS
and CLEAR_COMMAND from MSC.

Logical type

Variable

Unit

Integer number

Number

029035

Name

ADJ CELL ID 5

Release

S11.5

Description

Cell ID of the 5th strongest adjacent cell.

Updated

The Cell ID value is based on the last received MS report before the
TCH drop occured between messages ASSIGNMENT_COMPLETE
from BTS and DISCONNECT from MS/MSC or before the TCH drop
occured between messages ASSIGNMENT_COMPLETE from BTS
and CLEAR_COMMAND from MSC.

Logical type

Variable

Unit

Integer number

Number

029036

Name

RX LEVEL ADJ 5

Release

S11.5

Description

RX level value of the 5th strongest adjacent cell.

Updated

The RX level value is based on the last received MS report before


the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and CLEAR_COMMAND from
MSC.

Logical type

Variable

Unit

Integer number

26 (28)

# Nokia Corporation

DN0481217
Issue 2-0 en

Counters of Drop Call Breakdown Observation

Number

029037

Name

ADJ CELL PLMN ID 6

Release

S11.5

Description

PLMN ID of the 6th strongest adjacent cell.

Updated

The PLMN ID value is based on the last received MS report before


the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and CLEAR_COMMAND from
MSC.

Logical type

Variable

Unit

Integer number

Number

029038

Name

ADJ CELL LAC 6

Release

S11.5

Description

LAC of the 6th strongest adjacent cell.

Updated

The LAC value is based on the last received MS report before the
TCH drop occured between messages ASSIGNMENT_COMPLETE
from BTS and DISCONNECT from MS/MSC or before the TCH drop
occured between messages ASSIGNMENT_COMPLETE from BTS
and CLEAR_COMMAND from MSC.

Logical type

Variable

Unit

Integer number

Number

029039

Name

ADJ CELL ID 6

Release

S11.5

Description

Cell ID of the 6th strongest adjacent cell.

Updated

The Cell ID value is based on the last received MS report before the
TCH drop occured between messages ASSIGNMENT_COMPLETE
from BTS and DISCONNECT from MS/MSC or before the TCH drop
occured between messages ASSIGNMENT_COMPLETE from BTS
and CLEAR_COMMAND from MSC.

Logical type

Variable

Unit

Integer number

DN0481217
Issue 2-0 en

# Nokia Corporation

27 (28)

29 Drop Call Breakdown Observation

Number

029040

Name

RX LEVEL ADJ 6

Release

S11.5

Description

RX level value of the 6th strongest adjacent cell.

Updated

The RX level value is based on the last received MS report before


the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and DISCONNECT from MS/
MSC or before the TCH drop occured between messages
ASSIGNMENT_COMPLETE from BTS and CLEAR_COMMAND from
MSC.

Logical type

Variable

Unit

Integer number

Number

029041

Name

FOCUS OF BREAKDOWN

Release

S11.5

Description

Indicates to which counter the drop call breakdown observation is related.


Coding:
1 = breakdown of counter DROPS AFTER TCH ASSIGN
2 = breakdown of counter CLEAR REQUEST SENT BY BSC ON TCH

Updated

When the focus of the observation is on the breakdown of the counter


DROPS AFTER TCH ASSIGN, this counter is updated with value 1 when
the counter DROPS AFTER TCH ASSIGN is updated.
When the focus of the observation is on the breakdown of the counter
CLEAR REQUEST SENT BY BSC ON TCH, this counter is updated with
value 2 when the counter CLEAR REQUEST SENT BY BSC ON TCH is
updated.

Dependencies with other


counters/PI(s)

001202 - DROP AFTER TCH ASSIGN, 002071 - CLEAR REQUEST


SENT BY BSC ON TCH, 057044 - DROP AFTER TCH ASSIGNMENT

Logical type

Variable

Unit

bytes

Related topics

28 (28)

29 Drop Call Breakdown Observation

Call Related DX Causes in BSC

# Nokia Corporation

DN0481217
Issue 2-0 en

Вам также может понравиться