Part 1
ROTALIGN Ultra
System operating instructions
Part 2
ROTALIGN Ultra
Shaft alignment
operating instructions
Operating Instructions
Dear Customer,
If you have any suggestions for improvement or corrections (not
only to this manual, but also to software or hardware), please
drop us a line. We would be glad to make improvements wherever
possible. We look forward to hearing from you.
1-2
Contents
Contents
Chapter 1 Introducing ROTALIGN Ultra ........ 1-4 to 1-14
ROTALIGN Ultra Shaft package ........................................................... 1-4
Safety notes ....................................................................................... 1-6
Getting to know ROTALIGN Ultra ....................................................... 1-7
Laser and receiver ............................................................................. 1-10
1-3
Foreword
Foreword
ROTALIGN Ultra is a new generation portable laser alignment
system, used in the alignment of shafts, turbine components, bores,
and the measurement of straightness and flatness of different types
of surfaces. This expandable system is both a welcome replacement
for the proven ROTALIGN PRO system and an addition to the
existing high-end range of alignment products from PRFTECHNIK.
As with all PRFTECHNIK instruments, ROTALIGN Ultra is user
friendly. It has an intuitive user interface. It uses easy-to-follow icons
and comprehensive on-screen menus and hint texts, that even firsttime users are able to operate it without difficulty.
ROTALIGN Ultra is built to rugged industrial standards of shock and
water resistance. It contains a complete computer with a colour 480 x
320 VGA display and oval-shaped function keys. The computer
uses the well known PRFTECHNIK tradition of obtaining alignment
results with only three function key presses.
The system also uses the existing ROTALIGN laser, receiver and
brackets, making it an attractive upgrade for existing users of
ROTALIGN and ROTALIGN PRO.
This handbook sets out to help the instrument user work through the
instrument with the required ease. It is meant to be a quick learning
tool that hopefully should make compelling reading.
We welcome feedback so if anything is unclear, please let us know.
Ismaning, Germany
February 2005
1-4
Introducing ROTALIGN Ultra
ALI 4.200
ROTALIGN Ultra
computer
including:
ROTALIGN Ultra
rechargeable
battery ALI 4.603
ROTALIGN Ultra stand
ALI 4.201
ALI 3.610
Laser
including:
dust cap ALI 3.607
ALI 3.600
Receiver
including:
dust cap ALI 3.606
ALI 4.800
1-5
Introducing ROTALIGN Ultra
ALI 3.608
Adjustment tube
ALI 4.503
SYS 3.651
Battery charger
ALI 4.722 CD
ROTALIGN Ultra READER CD
(activation key label affixed)
ALI 3.588
1-6
Introducing ROTALIGN Ultra
Safety notes
ROTALIGN Ultra is to be used in industrial environments only for
alignment of turbine components, shafts, bores, measurement of
straightness and flatness of different surfaces. Care must be taken to
ensure that the instrument is not subjected to mechanical knocks.
ROTALIGN Ultra must be operated only by properly trained personnel. No liability will be assumed when components or operating
procedures as described in this manual are altered without permission of the manufacturer.
Safety symbols
The following symbols are used in this manual in order to draw the
reader's attention to especially important text, such as that regarding
possible sources of danger or useful operating tips.
Note
CAUTION
WARNING
Laser safety
The ROTALIGN Ultra system uses a class II laser beam. Class II lasers
comply with the requirements outlined in the USA's FDA specification
21 CFR Ch. 1, Parts 1040.10 and 1040.11 as well as the ANSI
standard. It also fulfills British standard BS 4803 (Part 1 to Part 3)
and European Industrial Standard IEC 825. The class II laser operates
1-7
Introducing ROTALIGN Ultra
Do not look directly into the laser beam at any time. (Since FDA
specifications allow maximum exposure of 0.25 seconds, the
natural blink reaction of the human eye is normally sufficient to
avert any danger, provided that no optical instruments other
than ordinary eye glasses/contact lenses are used.)
Do not insert any optical devices into the beam path.
WARNING
On/Off/Enter key
Navigation keys
Function keys
1-8
Introducing ROTALIGN Ultra
The navigation keys are used to navigate through the menu items.
The 'Enter' key in the center is used to access any selected item.
The 'On/Off/Enter' key is used to perform the dual function of
switching on ROTALIGN Ultra, and accessing any selected item. To
switch on, press and hold the 'On/Off/Enter' key for approximately 5
seconds.
The 'Up' key is used as a back/return key, taking user to previously
selected function.
The 'Clr' (Clear) key is used to delete information entered inadvertently.
The 'Menu' key is used to call menu options related to the selected
display screen.
The data entry keys are used to enter relavant data.
ROTALIGN Ultra possesses 3 function keys.
The 'Dimension' key is used to access machine set-up to define and
enter machine dimensions.
The 'Measurement' key is used to enter the alignment measurement
mode.
The 'Result' key is used to call alignment results into the display.
Power supply
ROTALIGN Ultra is powered using a 7.2 V 6.0 Ah Lithium-ion
rechargeable battery ALI 4.603, which is to be charged only using the
battery charger SYS 3.651. This can be done with the battery inside
the computer. The computer may continue to be used if the battery is
charged inside it.
Alternatively, use 6 standard 'C' size batteries contained in the battery
compartment ALI 4.605.
ROTALIGN Ultra top panel connectors
Charger socket
The red dot on the charger
plug must match the red
dot on the battery socket
1-9
Introducing ROTALIGN Ultra
Replacing batteries
The rechargeable battery ALI 4.603 and the battery compartment ALI
4.605 have identical shapes and are therefore replaceable.
If batteries require removal, turn over the computer taking care not
to damage the display and the hard keys. Undo the two screws by
turning them at least half a turn. With the screws loosened, lift and
pull the rechargeable battery or the battery compartment (depending
on power supply source) out. The reverse procedure is used to mount
back the rechargeable battery or the battery compartment.
Lift compartment or
rechargeable battery
after undoing the
screws
Replace compartment
or rechargeable
battery by sliding it
into the groove
appropriately
1-10
Laser and receiver
Rubber housing
Battery compartment
Horizontal
beam position
thumbwheel
Locking knob
On/Off
toggle switch
"Beam active"
indicator LED
Laser battery
The laser is powered by a single 9 V battery (type IEC 6LR61) which,
depending on battery make and operating patterns, provides a
typical operating duration of 80 hours. Lithium batteries of this size
can also be used, increasing operation up to 150 hours. NiCad
rechargeables may also be used.
CAUTION
1-11
Laser and receiver
)
Note
DURACELL
ALKALINE
DURACELL
ALKALINE
TI
0
.1
40
10 FR misty
C
s an
21 1 se rr
.1 u a
ith 0 a w
w 04 g c s
1
es R sin oid
pli CF ou d v
m
n
h
1
o
a
C d 2 g nt
in
an en e
p tm
O jus
o
ad /N
Ty
pe
ur
e
G
ct
AG
ifa
an
IK IN
m
N N
H A
C
E IS M
FT37
R 7
P 85
D
D
at
of
Receiver
ALI 3.600
The receiver contains two position detectors, located one behind the
other, which measure the exact position of the laser beam as the
shafts are rotated. The detectors are biaxial, analog, photoelectric
semiconductor position detectors with a resolution of better than
1 m / 1/1000 mm (or 0.04 mils) and an area of 18 mm x 18 mm /
0.7" x 0.7". The receiver also contains an electronic inclinometer
with resolution better than 2 for shaft rotation measurements.
CAUTION
)
Note
1-12
Laser and receiver
Rubber
housing
Scratchresistant lens
Locking
knob
Cable
socket
The receiver has two indicator LEDs on its front side, one green and
the other red, to indicate beam adjustment.
Red
LED
Green
LED
The laser beam is out of the position detector range and both the
red and green LEDs are blinking
very fast.
1-13
Laser and receiver
Cable connection
Insert the angled plug into the receiver socket as shown; note the
keyway indicating proper plug orientation. Screw down the cable
fitting to tighten the connection. The angled plug should be left
permanently connected to the receiver, even when storing the system
in its case, as this will help avoid damage to cable pins, plugs and
sockets.
1-14
Laser and receiver
Never turn the plug itself, as that can damage the cable pins!
CAUTION
2-1
Available applications
Use the navigation keys to access available applications. The navigation direction is either upwards/downwards or sideways.
2-2
Configuration
2-3
Configuration
Language selection
Accessing this section allows you to select preferred country language.
Use the upward/downward navigation key and highlight preferred
language. Press
to confirm
selection.
Setting units
Accessing this section allows you to change the units and precision of
physical quantities used in ROTALIGN Ultra.
Use the navigation keys to select
,
item requiring setting. Press
and highlight required unit from
the drop down menu that appears
using the upward/downward
to confirm
navigation key. Press
selection.
2-4
Configuration
while in the
Power management
This section displays the current battery status allows you to control
the power management features of shutdown, hibernate (sleep
mode), and standby.
modes, press
. Highlight required mode from the drop down
menu that appears using the
upward/downward navigation key.
to confirm selection.
Press
2-5
Configuration
Printer set-up
Accessing this section allows you to set-up printers and the printing
configuration on ROTALIGN Ultra.
Select printer by pressing
, and
highlighting required printer from
the drop down menu that appears
using the upward/downward
navigation key. Press
to confirm
selection.
Use the navigation keys to scroll through the settings and print
to select or edit an option or setting.
options. Press
More printing options can be accessed by pressing
print screen. The context menu appears.
while in the
Scroll the context menu using the
upward/downward navigation key.
Press
to confirm selection.
2-6
Configuration
Device info
Accessing this section allows you to see the current file space and
operating memory statistics, the CPU data, the ROTALIGN Ultra
serial number, and information about the core software used in the
device.
ROTALIGN Ultra
serial number
2-7
Configuration
Display settings
Accessing this section allows you to change the contrast and
brightness of the display screen.
The contrast is changed using / .
The display brightness is adjusted
using
/
.
Word completion
The word completion mechanism helps save keystrokes and time
while typing. It also helps you to make sure no properties are
misspelt. When a user begins the entry of a word already listed in the
system dictionary, the word is completed automatically.
The word completion screen displays choice of words available for
the automatic completion mechanism.
. The
2-8
Configuration
2-9
Configuration
Customization
Customization makes it possible to change the device settings such
that the information displayed and the appearance of the display are
suited to one's individual usage.
'Customization options' screen is accessed via the program manager.
Start the program manager and use the navigation keys to select
'Device configuration'.
Press
2-10
Configuration
Resume policy
This option is useful for the resume functionality of ROTALIGN Ultra.
The drop down menu reveals the following items:
2-11
Configuration
2-12
Configuration
2-13
Tips and tricks
Pressing
for approximately 3 seconds prompts the turn off
system dialog.
Pressing
Press
Press
While in the program manager, the data entry keys are used to
select the corresponding application icon in a numerically ascending order.
While in the program manager,
screen contrast.
and
Pressing
and holding on, while in results, cycles the results
between vertical (V), horizontal (H) and both H&V.
When entering data, pressing
cycles through the characters
that can be entered, and pressing 1 long enough enters the value
.
2-14
Index
Index
Configuration
Context menu items 2-12
Customization 2-9
Date and time 2-2
Device info 2-6
Display settings 2-7
Language selection 2-3
Power management 2-4
Printer set-up 2-5
Units 2-3
Word completion 2-7
Context menu 2-5
Customization options 2-10
D
Data entry keys 1-7
F
Function buttons 1-7, 1-8
Function keys 1-7, 1-8
I
Index 2-11
Laser
class II 1-6
laser active 1-11
Laser battery 1-10
'Laser centered 1-13
laser class II 1-6
'Laser end' 1-12
'Laser OK' 1-13
Laser safety 1-6
LEDs 1-12
Lithium-ion 1-8
N
Navigation buttons 1-7
Navigation keys 1-7, 1-8
New words
storing 2-8
testing 2-8
2-15
Index
O
On-Off-Enter key 1-7
Operating elements 1-7
Operating keys 1-7
P
Plug orientation 1-14
Power supply 1-8
Program manager 2-1
R
Rechargeable battery 1-8
Resume 2-10
ROTALIGN Ultra computer
Settings 2-1
switch on 2-1
S
Safety symbols 1-6
Serial number 2-6
Sleep mode 2-4
SYS 3.200 1-4
SYS 3.521-2 1-5
SYS 3.651 1-5
Battery charger 1-8
SYS 3.801 1-4
SYS 9.414.G 1-5
T
Thumbwheel 1-10
Time zone 2-2
Tips and tricks 2-13
U
Up key 1-7, 1-8