Вы находитесь на странице: 1из 12

Strainer

BOA-S
PN 6/16/25
DN 15-300
Flanged ends

Type Series Booklet

Legal information/Copyright
Type Series Booklet BOA-S
KSB Aktiengesellschaft Pegnitz
All rights reserved. Contents provided herein must neither be distributed, copied, reproduced, edited
or processed for any other purpose, nor otherwise transmitted, published or made available to a third
party without KSBs express written consent.
Subject to technical modification without prior notice.
KSB Aktiengesellschaft Frankenthal 2011

Check Valves and Strainers

Strainers

Check Valves and Strainers

Selection as per pressure/temperature ratings ( Page 4)

Strainers

Design details

BOA-S

Design
Y-pattern strainer
Strainer insert made of stainless steel
Strainer insert accurately guided in cover and body
Outside confined cover gasket
Drain plug
Size DN 150 and above: additional strainer basket made of
perforated stainless steel sheet
Flanges to DIN EN 1092-2 Type 21
Exterior coating: blue RAL 5002
The valves satisfy the safety requirements of Annex I of
the European Pressure Equipment Directive 97/23/EC (PED)
for fluids in Groups 1 and 2.
The valves do not have a potential internal source of
ignition and can be used in potentially explosive
atmospheres, Group II, category 2 (zones 1+21) and
category 3 (zones 2+22) to ATEX 94/9/EC.

Variants
Fine-mesh insert

Main applications
Hot-water heating systems
Air-conditioning systems
Process engineering
Chemical industry
Petrochemical industry
Sugar industry
Heat recovery systems
Boiler feed applications
Boiler recirculation
Paper and cellulose industry

Fluids handled
Hot water
Saturated steam
Thermal oil
Liquids not chemically or mechanically aggressive to the
valve materials.
Other fluids on request.

Operating data
Operating properties
Value
JL 1040
JS 1025
Nominal pressure
PN 6/16
PN 16/25
Nominal size
DN 15-300
DN 15-300
Max. permissible pressure
16 bar
25 bar
Max. permissible temperature 300 C
350 C
Characteristic

High temperature resistant paint, aluminium grey (JS 1025


only)
Other flange designs (JS 1025 only)
Certification to customer specification

Body materials
Overview of available materials
Material
Material number
EN-GJL-250
JL 1040
EN-GJS-400-18-LT JS 1025

Temperature limit
up to 300 C
up to 350 C

Product benefits
Long service life due to strainer insert made of stainless
steel.
Time and cost saving replacement of strainer insert
without removing the body insulation by using the studs
as centering aids.
Standard drain plug for easy inspection and drainage of
strainer, particularly of large-diameter strainers.

Related documents
Operating manual 0570.8

On all enquiries/orders please specify


1.

Type

2.

Nominal pressure

3.

Nominal size

4.

Material

5.

Variants

6.

Number of type series booklet

BOA-S

Check Valves and Strainers

Strainers

Pressure/temperature ratings
Test and operating pressures
Nominal
pressure
PN
6
16
16
25

Material

EN-GJL-250
EN-GJS-400-18-LT

Pressure and leak test


with water
P10, P113)
[bar]
9
24
24
37,5

Permissible operating pressures in bar at temperatures in C1) 2)

-10 to +120
6
16
16
25

150
5,4
14,4
15,5
24,3

180
5
13,4

200
4,8
12,8
14,7
23

230
4,4
11,8

250
4,2
11,2
13,9
21,8

300
3,6
9,6
12,8
20

Materials

Overview of available materials


Part No.
100

Description
Body

160

Cover

411.1

Joint ring

411.2
758

Joint ring
Strainer insert

191

Strainer basket

902

Stud

911

Drain plug

PN
6, 16
16, 25
6,16
16, 25
6, 16
16, 25
6, 16, 25
6, 16
16, 25
6, 16
16, 25
6, 16
16, 25
6, 16

Material
EN-GJL-250 (JL1040)
EN-GJS-400-18-LT (JS1025)
EN-GJL-250 (JL1040)
EN-GJS-400-18-LT (JS1025)
CrNi St / graphite
CrNi St / graphite
A4
X 6 CrNiTi 18 10 (1.4541)
X 5 CrNi 18 10 (1.4301)
X 6 CrNiTi 18 10 (1.4541)
X 5 CrNi 18 10 (1.4301)
5.6 or 8.8
C 35 E
A4 or A2

3)

Intermediate temperatures can be derived by linear interpolation.


Static load
DIN EN 12266-1 (P10, P11)

BOA-S

1)
2)

Note

DN 150 and above


DN 150 and above
gal ZN
gal ZN

350
11,2
17,5

Check Valves and Strainers

Strainers

Part No.

Description

920

Hexagon nut

PN
16, 25
6, 16
16, 25

Material
C 35 E
5-2 or 8
C 35 E

Note
gal ZN
gal ZN
gal ZN

Dimensions
EN-GJL-250 (JL1040) variant

Dimensions in mm
PN

DN

nxd

h1

h4

Drain plug

[kg]

15
20
25
32
40
50
65
80
100
125
150
200
15
20
25
32
40
50
65
80
100
125
150
200
250
300

130
150
160
180
200
230
290
310
350
400
480
600
130
150
160
180
200
230
290
310
350
400
480
600
730
850

80
90
100
120
130
140
160
190
210
240
265
320
95
105
115
140
150
165
185
200
220
250
285
340
405
460

55
65
75
90
100
110
130
150
170
200
225
280
65
75
85
100
110
125
145
160
180
210
240
295
355
410

4x11
4x11
4x11
4x14
4x14
4x14
4x14
4x18
4x18
8x18
8x18
8x18
4x14
4x14
4x14
4x18
4x18
4x18
4x18
8x18
8x18
8x18
8x22
12x22
12x26
12x26

12
14
14
16
16
16
16
18
18
20
20
22
14
16
16
18
18
20
20
22
24
26
26
30
32
32

90
100
115
135
150
160
180
215
240
280
330
405
90
100
115
135
150
160
180
215
240
280
330
405
540
680

135
160
180
215
240
250
285
330
395
455
525
650
135
160
180
215
240
250
285
330
395
455
525
650
870
1110

G "
G "
G "
G "
G "
G "
G "
G "
G "
G "
G "
G "
G "
G "
G "
G "
G "
G "
G "
G "
G "
G "
G "
G "
G "
G "

2,5
3
4,5
5,5
7
9
13
19
26
38
54
110
3
4
5
7
9
12
16
21
30
43
61
121
154
255

16

BOA-S

Check Valves and Strainers

Strainers

Dimensions in mm
PN

16

DN

15
20
25
32
40
50
65
80
100
125
150
200
15
20
25
32
40
50
65
80
100
125
150
200
250
300

KV [m/h]

Standard mesh
Zeta value Mesh width

5,7
10,4
16,4
27,3
42
64,7
96
149
223
347
480
853
5,7
10,4
16,4
27,3
42
64,7
96
149
223
347
480
853
1104
1450

2,5
2,4
2,3
2,3
2,3
2,4
3,1
3,0
3,2
3,2
3,5
3,5
2,5
2,4
2,3
2,3
2,3
2,4
3,1
3,0
3,2
3,2
3,5
3,5
5,1
6,1

1,0
1,0
1,0
1,0
1,0
1,0
1,25
1,25
1,6
1,6
1,6
1,6
1,0
1,0
1,0
1,0
1,0
1,0
1,25
1,25
1,6
1,6
1,6
1,6
1,6
1,6

Mating dimensions - Standards


Face-to-face lengths:
Flanges:
Flange facing:

BOA-S

DIN EN 558 FTF-1, ISO 5752/1


DIN EN 1092-2, flange type 21
DIN EN 1092-2, type B

Wire
diameter
0,5
0,5
0,5
0,5
0,5
0,5
0,63
0,63
1,0
1,0
1,0
1,0
0,5
0,5
0,5
0,5
0,5
0,5
0,63
0,63
1,0
1,0
1,0
1,0
1,0
1,0

KV [m/h]

Zeta value

5,3
9,5
15,1
24,7
38,2
57,2
81,1
119
181
281
380
672
5,3
9,5
15,1
24,7
38,2
57,2
81,1
119
181
281
380
672
838
1090

2,9
2,8
2,7
2,7
2,8
3,0
4,3
4,6
4,9
5,0
5,6
5,7
2,9
2,8
2,7
2,7
2,8
3,0
4,3
4,6
4,9
5,0
5,6
5,7
8,9
10,9

Fine mesh
Mesh width
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25

Wire
diameter
0,16
0,16
0,16
0,16
0,16
0,16
0,16
0,16
0,16
0,16
0,16
0,16
0,16
0,16
0,16
0,16
0,16
0,16
0,16
0,16
0,16
0,16
0,16
0,16
0,16
0,16

Check Valves and Strainers

Strainers

EN-GJS-400-18-LT (JS1025) variant

Dimensions in mm
PN

DN

nxd

h1

h4

Drain plug

[kg]

16

15
20
25
32
40
50
65
80
100
125
150
200
250
300
15
20
25
32
40
50
65
80
100
125
150
200

130
150
160
180
200
230
290
310
350
400
480
600
730
850
130
150
160
180
200
230
290
310
350
400
480
600

95
105
115
140
150
165
185
200
220
250
285
340
405
460
95
105
115
140
150
165
185
200
235
270
300
360

65
75
85
100
110
125
145
160
180
210
240
295
355
410
65
75
85
100
110
125
145
160
190
220
250
310

4x14
4x14
4x14
4x18
4x18
4x18
4x18
8x18
8x18
8x18
8x22
12x22
12x26
12x26
4x14
4x14
4x14
4x18
4x18
4x18
8x18
8x18
8x22
8x26
8x26
12x26

16
18
18
20
20
22
24
26
28
30
30
34
36
36
16
18
18
20
20
22
24
26
28
30
34
34

75
75
90
90
110
120
140
165
220
260
300
360
470
560
75
75
90
90
110
120
140
165
220
260
300
360

115
115
135
135
170
190
220
265
340
410
475
580
680
820
115
115
135
135
170
190
220
265
340
410
475
580

G "
G "
G "
G "
G "
G "
G "
G 1"
G 1"
G 1"
G 1"
G 1"
G 1"
G 1"
G "
G "
G "
G "
G "
G "
G "
G 1"
G 1"
G 1"
G 1"
G 1"

3,5
4
5,5
7
9
12
16
21
28
41
58
121
154
255
3,5
4
5,5
7
9
12
16
21
32
47
64
133

25

Dimensions in mm
PN

16

DN

15
20
25

KV [m/h]

Standard mesh
Zeta value Mesh width

6,3
11,3
18,5

2,1
2,0
1,8

1,25
1,25
1,25

Wire
diameter
0,71
0,71
0,71

KV [m/h]

Zeta value

5,0
9,0
14,8

3,2
3,2
2,9

Fine mesh
Mesh width
0,25
0,25
0,25

Wire
diameter
0,17
0,17
0,17

BOA-S

Check Valves and Strainers

Strainers

PN

25

DN

32
40
50
65
80
100
125
150
200
250
300
15
20
25
32
40
50
65
80
100
125
150
200

KV [m/h]

Standard mesh
Zeta value Mesh width

22,5
37,5
60,0
110,5
170,3
245,7
416,0
608,4
999,7
1440,4
1976,0
6,3
11,3
18,5
22,5
37,5
60,0
110,5
170,3
245,7
416,0
608,4
999,7

3,3
2,9
2,8
2,3
2,3
2,7
2,3
2,2
2,6
3,0
3,3
2,1
2,0
1,8
3,3
2,9
2,8
2,3
2,3
2,7
2,3
2,2
2,6

1,25
1,25
1,25
2,0
2,0
2,0
2,0
2,0
2,0
2,0
2,0
1,25
1,25
1,25
1,25
1,25
1,25
2,0
2,0
2,0
2,0
2,0
2,0

Wire
diameter
0,71
0,71
0,71
0,50
0,50
0,50
0,50
0,50
0,50
0,50
0,50
0,71
0,71
0,71
0,71
0,71
0,71
0,50
0,50
0,50
0,50
0,50
0,50

Mating dimensions - Standards


Face-to-face lengths:
Flanges:
Flange facing:

DIN EN 558 FTF-1, ISO 5752/1


DIN EN 1092-2, flange type 21-2
DIN EN 1092-2, type B

Installation instructions
The flow direction must correspond to the arrow
indicated on the valve body.
In both horizontal and vertical pipes, we recommend to
install the strainer with the strainer insert hanging downwards
to facilitate cleaning.

Horizontal installation

Vertical installation

EN 1515-4 "Selection of bolting for equipment subject to


the Pressure Equipment Directive 97/23/EC" and any plant
regulations governing the application in question must be
observed when selecting connecting elements between the
valve flange and the pipe flange.

BOA-S

KV [m/h]

Zeta value

18,0
30,0
48,0
85,0
131,0
189,0
320,0
494,0
818,0
1184,0
1631,0
5,0
9,0
14,8
18,0
30,0
48,0
85,0
131,0
189,0
320,0
494,0
818,0

5,2
4,6
4,4
4,0
3,8
4,5
3,8
3,3
3,8
4,5
4,9
3,2
3,2
2,9
5,2
4,6
4,4
4,0
3,8
4,5
3,8
3,3
3,8

Fine mesh
Mesh width
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25

Wire
diameter
0,17
0,17
0,17
0,17
0,17
0,17
0,17
0,17
0,17
0,17
0,17
0,17
0,17
0,17
0,17
0,17
0,17
0,17
0,17
0,17
0,17
0,17
0,17

Check Valves and Strainers

Strainers

Chemical resistance chart

Fluid handled

The information provided in this chemical resistance chart is


based on experience, the Dechema lists as well as
manufacturer information. Corrosion resistance is largely
dependent on the operating conditions, temperatures and
concentrations. Hydroabrasive wear in fluids containing solids
is not covered in this list. All information provided herein,
therefore, only serves as an orientation. Warranty claims may
not be asserted on the basis of this list!
Chemical resistance chart for water
Fluid handled

Max.
content

Max.
temp.

Brackish water6) 7)

A4)

B5)

Max.
content

Chemical resistance chart for refrigerants


Fluid handled
Ammonium hydroxide
Glycol (ethylene glycol)
Propylene glycol
Water-glycol mixture
Inorganic cooling brine,
ph 7,5 inhibited

Max.
content
30 %

Max.
temp.
25 C

50 %

40 C

Chemical resistance chart for thermal oils

Fluid handled

Fluid handled

Condensate8)

Oil-free cooling water6)


Oil-containing cooling
water6)

Hydrochloric acid
Sulphuric acid
(pure, techn., concentr.)
Sulphurous acid
Fatty acid
Nitric acid

Boiler feed water8)


Hot water6)
High-temperature hot
water8)

T = f (p)

Municipal waste water9)

Industrial waste water10)

Ozonised water6)

0,5 mg/kg

Pure water6)
Seawater
Scale-forming

water6) 7)

water6) 7)

Raw
Partly desalinated water
Fully desalinated water

Oil-water emulsion7)
Jet fuel

4)
5)
6)
7)
8)
9)
10)
11)

Max.
content

Fluid handled

Max.
content

Lye for bottle rinsers (e.g.


P3)7)
Lye for metal cleaning7)

A4)

B5)

Max.
temp.

A4)

B5)

Max.
temp.
80 C

A4)

B5)

80 C

Max.
temp.

A4)

B5)

Chemical resistance chart for steam


Max.
content

A4)

B5)

Saturated steam

Chemical resistance chart for other fluids

11)

B5)

Chemical resistance chart for cleaning agents

Fluid handled
Vegetable oils
Mineral oils
Synthetic oils
Crude oil
Petroleum
Light fuel oil
Heavy fuel oil
Linseed oil

Max.
temp.

A4)

Chemical resistance chart for acids

Fluid handled

Max.
temp.

Max.
content

Synthetic thermal oils


Mineral-based thermal oils

Chemical resistance chart for oils (aromatic content 5 mg/kg)


Max.
content

B5)

11)
11)

Petrol

Fire-fighting water6)
0,6 mg/kg

A4)

Kerosene

Service water6) 7)
Chlorinated water6)
Deionised water
(demineralised water)
Distilled water

Max.
temp.

Fluid handled
Sodium hydroxide
Natural gas
Oil-containing compressed
air
Dry chlorine
Ammonia
Butane (liquefied gas)
Aqueous glycerine

11)

Max.
content
< 50 %

Max.
temp.
50 C

30 C

A4)

B5)

EN-GJL-250 (JL 1040), Tmax. +300 C


EN-GJS-400-18-LT (JS 1025), Tmax. +350 C
General limits for water to be handled by valves made of non-alloyed materials: pH value 6,5 - 12; chloride ions (Cl)
< 150 mg/kg; chlorine (Cl) < 0,6 mg/kg.
Without solids
Water treatment must be in compliance with the guidelines for feed water (e.g. VdTV 1466, TRD 611, etc.): pH value
9,0; O content 0,02 mg/l
Biologically treated
Non-corrosive, non-abrasive
For safety reasons (ductility) we recommend to use EN-GJS-400-18-LT.

BOA-S

Check Valves and Strainers

Strainers

Fluid handled
Carbon dioxide (gas)
Carbon dioxide
(aqueous solution)

Max.
content

Max.
temp.

A4)

B5)

Key to the symbols


Symbol

10

Description
The fluid handled is not normally aggressive toward
the materials.
The fluid handled is aggressive toward the
materials. Valve cannot be used.
The material or valve can only be used under certain
operating conditions. Please enquire accordingly
stating the operating conditions such as
concentration, temperature, pH value and
composition of the fluid handled.

BOA-S

07.10.2011
7125.1/15-10

KSB Aktiengesellschaft
Johann-Klein-Strae 9 67227 Frankenthal (Germany)
Tel. +49 6233 86-0 Fax +49 6233 86-3882
E-Mail: valves@ksb.com www.ksb.com