Вы находитесь на странице: 1из 6

Huawei SVMS Project Front Office, customer complain Working Instruction

Reviewed by:

Azadeh Alimirzaie

Date:

Reviewed by:

Date:

Reviewed by:

Date:

Reviewed by:

Date:

15/02/2011

Huawei SVMS Project


Back Office
Radio Link Prompt Alarm Handling
process
Operation Owner :Azadeh

Update Notes
Date

Version
1.0

Description

Author

Detail review of alarm handling for radio Link Prompt


Alarm

Azadeh Alimirzaie

Huawei Technologies Co., Ltd. All rights reserved


Copyright Huawei Technologies Co., Ltd. 2010. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior
written consent of Huawei Technologies Co., Ltd.

Issue 02 (2010-03-08)

Huawei Proprietary and Confidential


Copyright Huawei
Technologies Co., Ltd.

Huawei SVMS Project Front Office, customer complain Working Instruction

Trademarks and Permissions


and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees
or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute the warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.

Issue 02 (2010-03-08)

Huawei Proprietary and Confidential


Copyright Huawei
Technologies Co., Ltd.

ii

Radio Link Prompt alarm


For this alarm at fist check the Sub Link No. in alarm location information.
There is 4 different type of Sublink Number:
Sublink Number0: Abnormal channel activation alarm
Sublink Number1: Abnormal channel release alarm
Sublink Number2: No traffic alarm
Sublink Number3: Power level imbalance between uplink and downlink alarm

Example; Sublink 0:

If the channel types or states between the BSC and BTS are not consistent, the BTS
might respond with a channel activation failure or not respond at all. This will bring
about a call failure and directly affect the traffic statistic specifications.
Handling:
Check whether the channel configuration and the current channel status on the BSC
side are consistent with those on the BTS side.
Check the channel configuration on the BSC side
1) Right-click on the target site in the navigation tree, and then chooses "Query BTS
Attributes" from the shortcut menu. Select "Channel" in "Object Type" on the right.
2) Select the target channel in the Objects Selection dialog box. Click "Query" to view
the channel configuration.

Huawei SVMS Project Back Office, Radio Link Prompt Alarm

2011

Check the channel configuration on the BTS side.


1) Log in to the SMT.
2) In the Site Maintenance Terminal System window, select "Channel" in the left pane
and then double-click "Channel Attributes Management" in the right pane.
3) The SMT obtains the latest data from the BTS. You can perform the refresh
operation to confirm the data accuracy

Example; Sublink1:

When the uplink or downlink is faulty, there is no correct interaction on the radio
interfaces. When a channel is activated, there will be no normal communication on the
channel on the Um interface. Finally the BSC will release the channel
Check the traffic measurement counters for interference.
Check whether the difference between Immediate Assignment Requests" and "
Immediate Assignment Successes" is greater than 400.

Issue 02 (2010-03-08)

Huawei Proprietary and Confidential


Copyright Huawei
Technologies Co., Ltd.

Huawei SVMS Project Back Office, Radio Link Prompt Alarm

2011

2: No traffic alarm:

May this site is a new site without subscribers. In this case, the alarm handling is not
necessary otherwise Check the connections between the jumper and the duplexer, between the
jumper and the feeder, between the jumper and the surge protection unit, and between the
jumper and the antenna and find
3: Power level imbalance between uplink and downlink alarm

For example T4461 had radio link prompt alarm on board Number 20, 21. If you can
check alarm location information; it is sub link No. of 3.

As below graph there is unbalance problem in uplink direction in both mentioned


TRXs.

Issue 02 (2010-03-08)

Huawei Proprietary and Confidential


Copyright Huawei
Technologies Co., Ltd.

Huawei SVMS Project Back Office, Radio Link Prompt Alarm

2011

Board Number 20:

Board Number 21:

After solving power unbalance Radio Link Alarm recovered.

Issue 02 (2010-03-08)

Huawei Proprietary and Confidential


Copyright Huawei
Technologies Co., Ltd.

Вам также может понравиться