Вы находитесь на странице: 1из 8

XLS1000 Fire Alarm System

SPECIFICATION DATA

FEATURES
Modular System Design for Small to Large
Applications
168-Character Display Area for Automatic Display of
System Messages and Alarms
Three-second Alarm Response Over Any Size Network
Total Network Wiring Over 300,000 Feet (91,440 m)
Eight Multiplexed Channels for Audio Source
Selection on One Pair of Wires
Zoned Audio Amplifiers
Slide-in LED and Switch Labels
Support for a Wide Variety of Detectors and Modules
Automatic Device and Panel Addressing

GENERAL

250 Devices Per Loop, 2500 Devices Per Node


750ms Signature Loop Alarm Response

The XLS1000 Fire Alarm System is an adaptable life safety


system for a wide range of building sizes from small to large.
It is modularly designed to fit stand-alone, single-node
systems as well as multi-node networks. XLS1000 Systems
can also incorporate audio functions that use the same
fundamental components as the fire alarm functions to
simplify system layouts.

Device Circuit Mapping


Proprietary and Local System Operations
For Retrofit, Existing Wire may be used if Electrically
Sound

System Definition Utility software helps define custom system


operations quickly and easily. Virtually all XLS1000 operating
features are software-controlled to provide for site
customization and the ability to quickly implement future
operational changes and upgrades.

U.S. Registered Trademark


Copyright 1998 Honeywell Inc. All Rights Reserved

74-2073-2

XLS1000 FIRE ALARM SYSTEM


all XLS1000 operating features are software-controlled.
System Definition Utility software helps define flexible system
operations quickly and easily.

DESCRIPTION
The XLS1000 Fire Alarm System is modularly designed for
easy customization to fit stand-alone, single-node systems as
well as multi-node networks. To simplify system layouts,
XLS1000 Systems also integrate audio functions using the
same fundamental components as the fire alarm functions. To
provide for site customization and the ability to quickly
implement future operational changes and upgrades, virtually

System Components:
The XLS1000 is housed in a wall box that can contain a
variety of system components arranged as shown in the
following diagram.

INNER DOOR
COVER

BOX
LOCAL RAIL
MODULES

CONTROL
DISPLAY MODULES

OUTER
DOOR

M10858

CHASSIS

System Components.

Main Display Interface Module:


The Main Display Interface module provides simple-tounderstand lights (LEDs) and switches to help emergency
operators execute system commands with confidence.
Common control switches and LEDs include (at minimum) a
Reset switch and LED; Alarm Silence switch and LED; Panel
Silence switch and LED; and Drill switch and LED. Eight lines
of 21 characters (168 characters total) display emergency
information in a useful text format. The following figure
illustrates the layout of the module.

The housing can be mounted flush (set back within a wall),


semi-flush (partially set into a wall), or on a wall surface. The
Chassis and Local Rail Modules provide a base for the
installation of one or modules (Control Display Modules) such
as a Main Display Interface module and a system of generic
modules that maximize design flexibility for custom systems.
The Inner Door Cover and Outer Door Cover protect the
components and provide an attractive finish to the system.

74-20732

XLS1000 FIRE ALARM SYSTEM


OPTIONAL DISPLAY
MODULE PANEL

MAIN DISPLAY
INTERFACE

City
Tie
Disa ble

Power
Reset

CPU
Fail

Test
Alarm
Silence

GND
Fault

Disable
La mp
Test

Panel
Silence

Drill
G.A.
Inhibit

COMMON
CONTROL
SWITCHES

General
Evacuation

8-LINE
DISPLAY
AREA

Alarm

Sup'y

Trouble

Monitor
Previous

4
7

3
6
5

Message
Next
More
details
Command
Menu

0
M10846

Optional Main Display Interface Module and Display Module Panel.


XLS1000 supports both single-node and multiple-node single
network systems. As a stand-alone panel (or single node), up
to four power supplies provide 28A of power with space
available for 5 to 21 local rail modules. A single panel
supports up to ten Loop Controllers (250 devices per loop,
2500 points total per node). With only conventional circuits,
panel capacity is up to 15 local rail modules which support
120 conventional zones. Up to half of the conventional circuits
can be Notification Appliance Circuits. A Main Display
Interface module and 19 Control Display module
configurations are available.

The eight-line text display area shows current date, current


time, and number of alarms on the first line. The next lines
show the first highest priority event, the last highest priority
event, and other information as applicable, so that operators
can view alarm data without opening the door of the XLS1000.
Note that a Main Display Interface module is not required in
remote nodes with no user interface requirements.
The Main Display Interface also provides a Command Menu
for maintenance functions such as disabling alarms or
generating reports for use by staff or service personnel.

Networks:
XLS1000 operates on a multi-priority peer-to-peer token ring
network. The multi-priority token ring gives XLS1000 an
exceptional alarm response time of less than 3 seconds
across the network, virtually independent of the total number
of nodes. XLS1000 token ring network configuration also
affords long distances between nodes. The distance between
panels on 14 AWG (2.087 sq. mm) wire is 5000 ft (1524 m).
With 64 nodes supported on a network, total network length
is in excess of 300,000 ft (91,440 m).

Display Modules:
Generic control/display modules provide membrane switches
with positive tactile feedback and colored LEDs to give the
emergency user the simplest of interfaces. To maximize
system layout flexibility, Control/Display module locations are
independent of the underlying connection hardware to the
local rail module. The LCD area displays custom event
messages of up to 42 characters.
Panel Capacities:
XLS1000 facilitates isolation of field wiring with building wiring
terminations made to removable terminal blocks on the local
rail modules. XLS1000 local rail modules include zone
amplifiers, Loop Controllers, conventional hardwired modules,
and the main CPU module. System design allows convenient
separation of high voltage from power-limited wiring.

Network communication is via RS-485 serial ports. This twowire circuit supports Class A or B. The XLS1000 network
meets NFPA style 7 communications standards in Class A
configuration.

74-20732

XLS1000 FIRE ALARM SYSTEM


Audio system amplifiers can operate 25 Vrms or 70.4 Vrms
speakers. The system provides simultaneous page, alert, and
evacuation signaling. The system provides the following
paging common controls and indicators (at a minimum):

The XLS1000 uses distributed database technology designed


to survive the rigors of fire and fire fighting. In a Class B
configuration, a single break or short on the network wiring
isolates the system into two groups of panels, each with one or
more nodes. Each group of panels re-configures into a
peer-to-peer subnetwork, working with their combined
databases. In Class A, a single break or short on the network
wiring causes the system to isolate the fault. Network
communication continues uninterrupted. If multiple faults
occur, the network re-configures into multiple networks and
functions as described for Class B. The system continues to
respond to operations at every node able to receive network
messages with those nodes always executing the local
response.

Ready to page LED


VU display of paging output level
Single switch function for paging to all - Alert zones,
Evacuation zones, or areas not programmed for signaling.
Alarm Annunciation:
XLS1000 provides Alarm, Supervisory, Trouble, and Monitor
operations. Annunciation is through the use of LED display
strips complete with custom labels for each LED as to its
function. Where applicable, control of remote smoke control
devices is available at the control center. Switches with LEDs
provide positive feed back to the operator of remote
equipment status. See the Optional Main Display Interface
Module and Display Module Panel figure for an example.

Audio Functionality:
XLS1000 integrates audio components in its standard fire
alarm cabinet assemblies. XLS1000 uses intelligent zone
amplifiers to reduce wire runs and space needs at a central
location. Audio control equipment and zone amplifiers use the
same system power supplies as the fire alarm components. All
these components use a common standby battery. For
multiple-node systems, , a single pair of wires carries eight
channels of digital audio data between nodes. The system can
deliver up to eight messages and/or signals simultaneously, so
signaling messages to occupants are never interrupted. This
feature eliminates confusion if the emergency user requires an
audio channel with zone-specific messages.

Support for a Wide Variety of Fire Alarm Equipment:


XLS1000 supports a variety of conventional smoke detectors
with a single universal module. It also supports polarized
bells, horns, and strobes, as well as hardwired supervisory
and monitor functions with latching or non-latching operations.
Any circuit located anywhere on the network can display on
any LCD or LED annunciator.
Battery Options:
Available cabinet room allows for system batteries up to 17
Ah. One 24V backup battery supports up to four power
supplies. The power supplies are arranged in parallel to
ensure optimization of the full capacity each power supply.
Each supply provides up to 7A of current, therefore, with four
supplies, 28A of current is available, all backed up by one
battery. A single panel or node supports batteries up to 65 Ah
to give XLS1000 initial system cost savings, as well as
continuing cost saving benefits in system maintenance.

The XLS1000 provides simple paging controls. ALL CALL


operation selects all paging zones for message delivery. Page
to EVACUATION operation automatically selects all areas in
evacuation. Similarly, the user can Page to ALERT. Zoned
paging requires the user to simply select a zone paging switch.
After the user completes a page delivery, signaling
automatically restores after the user releases the microphone
talk key.

74-20732

XLS1000 FIRE ALARM SYSTEM

TYPICAL WIRING
4TH FLOOR

REMOTE
FLOOR PANEL

LEGEND
CPU, POWER SUPPLY AND BOOSTER,
DUAL LOOP MODULE, THREE
AMPLIFIERS, AND BATTERIES

PRIMARY
POWER
SOURCE

F
S
R

3RD FLOOR
2 PR

SMOKE DETECTOR
WITH RELAY BASE

SMOKE DETECTOR
WITH ISOLATOR BASE

SMOKE DETECTOR

2 PR

MANUAL PULL
STATION

WITH STANDARD BASE


J

1 TW/SH PR

CC

1 PR & 2 TW/SH PR
1 PR

2 TWISTED PAIR
1 TWISTED/
SHIELDED PAIR

MM

HVAC MONITOR

CR

HVAC CONTROL

TELEPHONE

F
CR

ELEVATOR
CAPTURE
NETWORK CONTROL
AUDIO, AND TELEPHONE

JUNCTION BOX
COMBINATION
SPEAKER/STROBE
FIREFIGHTER'S

CC

SIGNAL MODULE

CR

CONTROL RELAY
MODULE

WATERFLOW
CT
SWITCH
SPRINKLER
SUPERVISORY
SWITCH

CT

INPUT MODULE

UM

UNIVERSAL INPUT/

CT
OUTPUT MODULE

2ND FLOOR

MM

MONITOR MODULE
END-OF-LINE
RESISTOR

2 PR

S
1

CR

2 PR

MM

HVAC
CONTROL
1 PAIR

SR
FIRE
F
DAMPER

HVAC
MONITOR

F
WATER LEVER

MM

SIZE CONDUCTORS PER


APPLICATION. REFER TO
INSTALLATION MANUAL
FOR ADDITIONAL DETAILS.

MONITOR

CC
1 TW/SH PR
1 PAIR AND 2 TWISTED/SHIELDED PAIR

1ST FLOOR

2 PR.

2 PR.

J
S

1 PAIR

1 PAIR AND
2 TWISTED/
SHIELDED PAIR

F
CC
XLS1000
PANEL

1 TWISTED SHIELDED PAIR

PRIMARY
POWER
SOURCE

PRINTER

OPTIONAL REMOTE
CPU WITH DISPLAY, POWER SUPPLY
COMMAND SYSTEM
AND BOOSTER, DUAL LOOP MODULE,
AUDIO SOURCE WITH MASTER FIREFIGHTERS'S
TELEPHONE, TWO AMPLIFIERS, AND BATTERIES

GROUND FLOOR
M10847

74-20732

XLS1000 FIRE ALARM SYSTEM

ORDERING
Loop Controller
Catalog Number
3-DSDC

Description
Dual SIGA Data Controller with one SIGA Data Board. Mounts to Local Rail.

Modules, Amplifiers, Power Supplies, and Boards


Catalog Number

Description

3-LDSM

LED Display Support Module

3-24R

24 Red LED Display Module

3-24Y

24 Yellow LED Display Module

3-24G

24 Green LED Display Module

3-12SR

12 switches with 12 Red LED Display/Control Module

3-12SY

12 switches with 12 Yellow LED Display/Control Module

3-12SG

12 switches with 12 Green LED Display/Control Module

3-12RY

12 Red LED and 12 Yellow LED Display Module

3-12/2Y

12 groups of two Yellow LED Display Module

3-12/RY

12 groups of one Red and one Yellow LED Display Module

3-12/S1GY

12 switches with one Green and one Yellow LED per switch Display/Control Module

3-12/S1RY

12 switches with one Red and one Yellow LED per switch Display/Control Module

3-ZA15

15W Zoned Amplifier Selectable for 70 or 25Vrms operation

3-ZA30

30W Zoned Amplifier Selectable for 70 or 25 Vrms operation

3-PPS/M

Primary Power Supply with local rail module 120V 50/60 Hz

3-BPS/M

Booster Power Supply with local rail module 120V 50/60 Hz

3-PPS/M-230

Primary Power Supply with local rail module 230V 50/60Hz

3-BPS/M-230

Booster Power Supply with local rail module 230V 50/60 Hz

3-IDC8/4

Initiating Device Circuit Module

3-OPS

Off Premises Signaling module

3-ASUFT

Audio Source Unit with local microphone and Firefighters Telephone

3-ASU

Audio Source Unit with Local Microphone. Provides four local rail spaces.

3-ASUMX

Audio Source Unit Memory Expansion. Provides 36 minutes of message time.

3-CPU

Main Panel Processor

3-XMEM

Memory Expansion Board

3-RS485

Network Communication Board

3-RS232

RS-232 Communication Board

74-20732

XLS1000 FIRE ALARM SYSTEM


Lobby Enclosures - Outer doors with Viewing Window
3-CAB5

Cabinet w/Wallbox and door

5 local rail modules


One footprint and 1/2 footprint module

two - 12V10A

3-CAB7B

Wallbox only

1- Chassis

two - 12V17A

3-CAB7D

Inner door and outer doors


for 3-CAB7B

N/A

N/A

3-CAB14B

Wallbox only

2 Chassis

two - 12V17A

3-CAB14D

Inner door and outer doors


for 3-CAB14B

N/A

N/A

3-CAB21B

Wallbox only

3 Chassis

two - 12V17A

3-CAB21D

Inner door and outer doors


for 3-CAB21B

N/A

N/A

Remote Chassis Enclosure - No viewing window


3-RCC7

Wallbox with outer louvered cover

1 Chassis

two - 12V17A

3-RCC14

Wallbox with outer louvered cover

2 Chassis

two - 12V17A

3-RCC21

Wallbox with outer louvered cover

3 Chassis

two - 12V17A

Chassis Assemblies
3-CHASS

Chassis Assembly - Takes one Chassis space in wallbox, no local rail module mounting, Space
for up to two power supplies and a 1/2 footprint module.

3-CHAS7

Chassis Assembly - Takes one Chassis space in wallbox, provides 7 local rail module spaces,
space for up to two power supplies and a 1/2 footprint module.

3-CHAS4

Chassis Assembly - Takes one Chassis space in wallbox, provides 4 local rail module spaces,
provides space for a Audio source card, paging common control and four local rail modules.

Battery Cabinet
3-BC

Space for two 20 to 65 Ah batteries. Provision for remote temperature monitoring. Provides
terminals for up to four Power Supplies.

Accessories
3-TAMP

Tamper switch for 3-CAB series cabinets. Mounts to side of cabinet.

3-LCD

Main Display Interface /w LCD

NOTE:

All cabinets and doors have a textured white enamel finish, doors are available as red by adding the suffix -R to catalog
number, for example, CAB7D-R.

74-20732

XLS1000 FIRE ALARM SYSTEM


Electrical Characteristics:
Operating Voltage: 24 Vdc
Operating Alarm Current: 7.0 A max./power supply

SPECIFICATIONS
Model:
o XLS1000 Fire Alarm System
Power Input:
Each XLS1000 can support up to 4 power supplies, depending
on the cabinet configuration. There can be only one 3-PPS/M
primary power supply, and up to three 3-BPS/M booster power
supplies.
3-PPS/M or 3-BPS/M
3.0A, 50-60 Hz.
3-PPS/M-230 or 3-BPS/M-230
1.5A, 50-60 Hz.

120 VAC +10%, -15%,


230 VAC +10%, -15%,

WARNING!
This product must be installed and operated within its
environmental, mechanical, and electrical
specifications as contained in this document. In case
of service, use only listed/approved replacement parts
ordered directly from the manufacturer. Failure to do
so can result in loss of safety function, degraded
operation, or damage to this product.

Operating Environment:
32 Deg. F (0 Deg. C) to 120 Deg. F (49 Deg. C), 93% RH,
non-condensing

Home and Building Control


Honeywell Inc.
Honeywell Plaza
P.O. Box 524
Minneapolis MN 55408-0524

Home and Building Control


Honeywell Limited-Honeywell Limite
155 Gordon Baker Road
North York, Ontario
M2H 3N7

Honeywell Latin American Region


480 Sawgrass Corporate Parkway
Suite 200
Sunrise FL 33325

Honeywell Europe S.A.


3 Avenue du Bourget
1140 Brussels
Belgium

74-20732 T.M. Rev. 2-98

Printed in U.S.A. on recycled


paper containing at least 10%
post-consumer paper fibers.

Honeywell Asia Pacific Inc.


Room 3213-3225
Sun Hung Kai Centre
No. 30 Harbour Road
Wanchai
Hong Kong

www.honeywell.com

Вам также может понравиться